Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D
2013-11-01
There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.
Aguirre, Erik; Iturri, Peio Lopez; Azpilicueta, Leire; de Miguel-Bilbao, Silvia; Ramos, Victoria; Gárate, Uxue; Falcone, Francisco
2015-03-01
A high number of wireless technologies can be found operating in vehicular environments with the aim of offering different services. The dosimetric evaluation of this kind of scenarios must be performed in order to assess their compatibility with current exposure limits. In this work, a dosimetric evaluation inside a conventional car is performed, with the aid of an in-house 3D Ray Launching computational code, which has been compared with measurement results of wireless sensor networks located inside the vehicle. These results can aid in an adequate assessment of human exposure to non-ionizing radiofrequency fields, taking into account the impact of the morphology and the topology of the vehicle for current as well as for future exposure limits.
Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography
Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji
2013-01-01
OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume < −950 HU of each lobe using (i) the slice-by-slice method (reference standard), (ii) number of segments method, and (iii) semi-automatic and (iv) automatic computer-aided diagnosis. We determined Pearson correlation coefficients between the reference standard and the three other methods for lobar volumes and emphysematous lobar volumes. We also compared the relative errors among the three measurement methods. RESULTS Both semi-automatic and automatic computer-aided diagnosis results were more strongly correlated with the reference standard than the number of segments method. The correlation coefficients for automatic computer-aided diagnosis were slightly lower than those for semi-automatic computer-aided diagnosis because there was one outlier among 50 cases (2%) in the right upper lobe and two outliers among 50 cases (4%) in the other lobes. The number of segments method relative error was significantly greater than those for semi-automatic and automatic computer-aided diagnosis (P < 0.001). The computational time for automatic computer-aided diagnosis was 1/2 to 2/3 than that of semi-automatic computer-aided diagnosis. CONCLUSIONS A novel lobar volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418
Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.
Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu
2012-09-01
The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.
Lin, Chun-Li; Chang, Yen-Hsiang; Hsieh, Shih-Kai; Chang, Wen-Jen
2013-03-01
This study evaluated the risk of failure for an endodontically treated premolar with different crack depths, which was shearing toward the pulp chamber and was restored by using 3 different computer-aided design/computer-aided manufacturing ceramic restoration configurations. Three 3-dimensional finite element models designed with computer-aided design/computer-aided manufacturing ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with finite element analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restorations exhibited the lowest values relative to the other 2 restoration methods. Weibull analysis revealed that the overall failure probabilities in a shallow cracked premolar were 27%, 2%, and 1% for the onlay, endocrown, and conventional crown restorations, respectively, in the normal occlusal condition. The corresponding values were 70%, 10%, and 2% for the depth cracked premolar. This numeric investigation suggests that the endocrown provides sufficient fracture resistance only in a shallow cracked premolar with endodontic treatment. The conventional crown treatment can immobilize the premolar for different cracked depths with lower failure risk. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.
Pendola, Martin; Saha, Subrata
2015-01-01
Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.
A Computer-Aided Exercise for Checking Novices' Understanding of Market Equilibrium Changes.
ERIC Educational Resources Information Center
Katz, Arnold
1999-01-01
Describes a computer-aided supplement to the introductory microeconomics course that enhances students' understanding with simulation-based tools for reviewing what they have learned from lectures and conventional textbooks about comparing market equilibria. Includes a discussion of students' learning progressions and retention after using the…
Fang, Liping; Zheng, Minghui; Liu, Guorui; Zhao, Yuyang; Liu, Wenbin; Huang, Linyan; Guo, Li
2017-02-01
Enzyme-aided Cl 2 bleaching is widely considered as promising replacements for conventional Cl 2 bleaching in wood pulp and paper mills. However, the effects of using enzyme-aided bleaching on the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the non-wood pulp and paper mills are unclear. A field study was performed to investigate PCDD/F formation when enzyme-aided Cl 2 bleaching was used to replace conventional Cl 2 bleaching in non-wood pulp and paper mills. Unexpectedly, the PCDD/F toxic equivalents (TEQs) in solid samples were higher when using enzyme-aided bleaching (0.49-5.4 pg TEQ/g) than that using conventional Cl 2 bleaching (0.15-2.44 pg TEQ/g). Large amounts of octachlorodibenzo-p-dioxin were formed during the enzyme-aided bleaching process. This could have been because enzyme strongly promoted the release of organic molecules bound to lignin and thus accelerated the formation of octachlorodibenzo-p-dioxin through organic molecular precursors. Although enzyme-aided Cl 2 bleaching was previously considered to be efficient for reducing PCDD/F releases and to be the best available technologies and best environmental practices for wood pulp and paper mills, the results obtained in this study suggested the necessity and urgency to evaluate the suitability of enzyme-aided Cl 2 bleaching for non-wood pulp and paper mills that intensively practiced in developing countries. Copyright © 2016 Elsevier Ltd. All rights reserved.
The National Shipbuilding Research Program, Computer Aided Process Planning for Shipyards
1986-08-01
Factory Simulation with Conventional Factory Planning Techniques Financial Justification of State-of-the-Art Investment: A Study Using CAPP I–5 T I T L...and engineer to order.” “Factory Simulation: Approach to Integration of Computer- Based Factory Simulation with Conventional Factory Planning Techniques
Vascular tissue engineering by computer-aided laser micromachining.
Doraiswamy, Anand; Narayan, Roger J
2010-04-28
Many conventional technologies for fabricating tissue engineering scaffolds are not suitable for fabricating scaffolds with patient-specific attributes. For example, many conventional technologies for fabricating tissue engineering scaffolds do not provide control over overall scaffold geometry or over cell position within the scaffold. In this study, the use of computer-aided laser micromachining to create scaffolds for vascular tissue networks was investigated. Computer-aided laser micromachining was used to construct patterned surfaces in agarose or in silicon, which were used for differential adherence and growth of cells into vascular tissue networks. Concentric three-ring structures were fabricated on agarose hydrogel substrates, in which the inner ring contained human aortic endothelial cells, the middle ring contained HA587 human elastin and the outer ring contained human aortic vascular smooth muscle cells. Basement membrane matrix containing vascular endothelial growth factor and heparin was to promote proliferation of human aortic endothelial cells within the vascular tissue networks. Computer-aided laser micromachining provides a unique approach to fabricate small-diameter blood vessels for bypass surgery as well as other artificial tissues with complex geometries.
Computer-aided US diagnosis of breast lesions by using cell-based contour grouping.
Cheng, Jie-Zhi; Chou, Yi-Hong; Huang, Chiun-Sheng; Chang, Yeun-Chung; Tiu, Chui-Mei; Chen, Kuei-Wu; Chen, Chung-Ming
2010-06-01
To develop a computer-aided diagnostic algorithm with automatic boundary delineation for differential diagnosis of benign and malignant breast lesions at ultrasonography (US) and investigate the effect of boundary quality on the performance of a computer-aided diagnostic algorithm. This was an institutional review board-approved retrospective study with waiver of informed consent. A cell-based contour grouping (CBCG) segmentation algorithm was used to delineate the lesion boundaries automatically. Seven morphologic features were extracted. The classifier was a logistic regression function. Five hundred twenty breast US scans were obtained from 520 subjects (age range, 15-89 years), including 275 benign (mean size, 15 mm; range, 5-35 mm) and 245 malignant (mean size, 18 mm; range, 8-29 mm) lesions. The newly developed computer-aided diagnostic algorithm was evaluated on the basis of boundary quality and differentiation performance. The segmentation algorithms and features in two conventional computer-aided diagnostic algorithms were used for comparative study. The CBCG-generated boundaries were shown to be comparable with the manually delineated boundaries. The area under the receiver operating characteristic curve (AUC) and differentiation accuracy were 0.968 +/- 0.010 and 93.1% +/- 0.7, respectively, for all 520 breast lesions. At the 5% significance level, the newly developed algorithm was shown to be superior to the use of the boundaries and features of the two conventional computer-aided diagnostic algorithms in terms of AUC (0.974 +/- 0.007 versus 0.890 +/- 0.008 and 0.788 +/- 0.024, respectively). The newly developed computer-aided diagnostic algorithm that used a CBCG segmentation method to measure boundaries achieved a high differentiation performance. Copyright RSNA, 2010
Forest and range mapping in the Houston area with ERTS-1
NASA Technical Reports Server (NTRS)
Heath, G. R.; Parker, H. D.
1973-01-01
ERTS-1 data acquired over the Houston area has been analyzed for applications to forest and range mapping. In the field of forestry the Sam Houston National Forest (Texas) was chosen as a test site, (Scene ID 1037-16244). Conventional imagery interpretation as well as computer processing methods were used to make classification maps of timber species, condition and land-use. The results were compared with timber stand maps which were obtained from aircraft imagery and checked in the field. The preliminary investigations show that conventional interpretation techniques indicated an accuracy in classification of 63 percent. The computer-aided interpretations made by a clustering technique gave 70 percent accuracy. Computer-aided and conventional multispectral analysis techniques were applied to range vegetation type mapping in the gulf coast marsh. Two species of salt marsh grasses were mapped.
Juntavee, Niwut; Sirisathit, Issarawas
2018-01-01
This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p <0.05). Tukey's HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration ( p <0.05). Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.
Lin, Wei-Shao; Metz, Michael J; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean
2014-12-01
This dental technique report describes a digital workflow with digital data acquisition at the implant level, computer-aided design and computer-aided manufacturing fabricated, tissue-colored, anodized titanium framework, individually luted zirconium oxide restorations, and autopolymerizing injection-molded acrylic resin to fabricate an implant-supported, metal-ceramic-resin fixed complete dental prosthesis in an edentulous mandible. The 1-step computer-aided design and computer-aided manufacturing fabrication of titanium framework and zirconium oxide restorations can provide a cost-effective alternative to the conventional metal-resin fixed complete dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
CAD/CAM complete dentures: a review of two commercial fabrication systems.
Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z
2013-06-01
The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.
Jo, Chanwoo; Bae, Doohwan; Choi, Byungho; Kim, Jihun
2017-05-01
Supernumerary teeth need to be removed because they can cause various complications. Caution is needed because their removal can cause damage to permanent teeth or tooth germs in the local vicinity. Surgical guides have recently been used in maxillofacial surgery. Because surgical guides are designed through preoperative analysis by computer-aided design software and fabricated using a 3-dimensional printer applying computer-aided manufacturing technology, they increase the accuracy and predictability of surgery. This report describes 2 cases of removal of a mesiodens-1 from a child and 1 from an adolescent-using a surgical guide; these would have been difficult to remove with conventional surgical methods. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M
2018-02-01
Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged <11 years (mean age of 6.9, range 2.5-10 years) with a bruise were recruited from the community. Demographics and bruise details were recorded. Each bruise was measured in vivo using a paper measuring tape. Standardised conventional and cross polarized digital images were obtained. The diameter of bruise images were measured by three computer aided measurement techniques: Image J (segmentation with Simple Interactive Object Extraction (maximum Feret diameter), 'Circular Selection Tool' (Circle diameter), & the Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p < 0.05 for all tests. Images were available for 38 bruises in vivo, with 48 bruises visible on cross polarized imaging and 46 on conventional imaging (some bruises interpreted as being single in vivo appeared to be multiple in digital images). Correlation coefficients were >0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen
2015-01-01
Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. PMID:26346558
Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen
2015-01-01
Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain.
Sirisathit, Issarawas
2018-01-01
Objective This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. Materials and methods A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05). Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05). Conclusion Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration. PMID:29497334
Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X
2017-02-18
To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time-consuming both in the clinical and laboratory process than the conventional custom trays. In addition, when we manufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being popularized.
Poggio, Claudio; Pigozzo, Marco; Ceci, Matteo; Scribante, Andrea; Beltrami, Riccardo; Chiesa, Marco
2016-01-01
Background: The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. Materials and Methods: In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The specimens were randomly assigned into 3 groups of 10 teeth each. In Group 1, disks were cemented using a total-etch protocol (Scotchbond™ Universal Etchant phosphoric acid + Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 2, disks were cemented using a self-etch protocol (Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 3, disks were cemented using a self-adhesive protocol (RelyX™ Unicem 2 Automix self-adhesive resin cement). All cemented specimens were placed in a universal testing machine (Instron Universal Testing Machine 3343) and submitted to a shear bond strength test to check the strength of adhesion between the two substrates, dentin, and RNC disks. Specimens were stressed at a crosshead speed of 1 mm/min. Data were analyzed with analysis of variance and post-hoc Tukey's test at a level of significance of 0.05. Results: Post-hoc Tukey testing showed that the highest shear strength values (P < 0.001) were reported in Group 2. The lowest data (P < 0.001) were recorded in Group 3. Conclusion: Within the limitations of this in vitro study, conventional resin cements (coupled with etch and rinse or self-etch adhesives) showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion. PMID:27076822
Poggio, Claudio; Pigozzo, Marco; Ceci, Matteo; Scribante, Andrea; Beltrami, Riccardo; Chiesa, Marco
2016-01-01
The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The specimens were randomly assigned into 3 groups of 10 teeth each. In Group 1, disks were cemented using a total-etch protocol (Scotchbond™ Universal Etchant phosphoric acid + Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 2, disks were cemented using a self-etch protocol (Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 3, disks were cemented using a self-adhesive protocol (RelyX™ Unicem 2 Automix self-adhesive resin cement). All cemented specimens were placed in a universal testing machine (Instron Universal Testing Machine 3343) and submitted to a shear bond strength test to check the strength of adhesion between the two substrates, dentin, and RNC disks. Specimens were stressed at a crosshead speed of 1 mm/min. Data were analyzed with analysis of variance and post-hoc Tukey's test at a level of significance of 0.05. Post-hoc Tukey testing showed that the highest shear strength values (P < 0.001) were reported in Group 2. The lowest data (P < 0.001) were recorded in Group 3. Within the limitations of this in vitro study, conventional resin cements (coupled with etch and rinse or self-etch adhesives) showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion.
Baroudi, Kusai; Ibraheem, Shukran Nasser
2015-01-01
Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082
Jan Wiedenbeck; Jeff Parsons; Bruce Beeken
2009-01-01
Computer-aided manufacturing (CAM), in which computer-aided design (CAD) and computer numerically controlled (CNC) machining are integrated for the production of parts, became a viable option for the woodworking industry in the 1980s.
NASA Technical Reports Server (NTRS)
Erb, R. B.
1974-01-01
The results of the ERTS-1 investigations conducted by the Earth Observations Division at the NASA Lyndon B. Johnson Space Center are summarized in this report, which is an overview of documents detailing individual investigations. Conventional image interpretation and computer-aided classification procedures were the two basic techniques used in analyzing the data for detecting, identifying, locating, and measuring surface features related to earth resources. Data from the ERTS-1 multispectral scanner system were useful for all applications studied, which included agriculture, coastal and estuarine analysis, forestry, range, land use and urban land use, and signature extension. Percentage classification accuracies are cited for the conventional and computer-aided techniques.
Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.
Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard
2017-10-15
The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.
Chang, Wen-Yu; Huang, Adam; Chen, Yin-Chun; Lin, Chi-Wei; Tsai, John; Yang, Chung-Kai; Huang, Yin-Tseng; Wu, Yi-Fan; Chen, Gwo-Shing
2015-05-03
To investigate the feasibility of manual segmentation by users of different backgrounds in a previously developed multifeature computer-aided diagnosis (CADx) system to classify melanocytic and non-melanocytic skin lesions based on conventional digital photographic images. In total, 347 conventional photographs of melanocytic and non-melanocytic skin lesions were retrospectively reviewed, and manually segmented by two groups of physicians, dermatologists and general practitioners, as well as by an automated segmentation software program, JSEG. The performance of CADx based on inputs from these two groups of physicians and that of the JSEG program was compared using feature agreement analysis. The estimated area under the receiver operating characteristic curve for classification of benign or malignant skin lesions based were comparable on individual segmentation by the gold standard (0.893, 95% CI 0.856 to 0.930), dermatologists (0.886, 95% CI 0.863 to 0.908), general practitioners (0.883, 95% CI 0.864 to 0.903) and JSEG (0.856, 95% CI 0.812 to 0.899). The agreement in the malignancy probability scores among the physicians was excellent (intraclass correlation coefficient: 0.91). By selecting an optimal cut-off value of malignancy probability score, the sensitivity and specificity were 80.07% and 81.47% for dermatologists and 79.90% and 80.20% for general practitioners. This study suggests that manual segmentation by general practitioners is feasible in the described CADx system for classifying benign and malignant skin lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Dental students' preferences and performance in crown design: conventional wax-added versus CAD.
Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A
2014-12-01
The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.
An Evaluation of Computer-Aided Instruction in an Introductory Biostatistics Course.
ERIC Educational Resources Information Center
Forsythe, Alan B.; Freed, James R.
1979-01-01
Evaluates the effectiveness of computer assisted instruction for teaching biostatistics to first year students at the UCLA School of Dentistry. Results do not demonstrate the superiority of CAI but do suggest that CAI compares favorably to conventional lecture and programed instruction methods. (RAO)
Lee, Wan-Sun; Kim, Woong-Chul
2015-01-01
PURPOSE To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced. PMID:25932310
Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan
2015-04-01
To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.
Lin, Chun-Li; Chang, Yen-Hsiang; Pa, Che-An
2009-10-01
This study evaluated the risk of failure for an endodontically treated premolar with mesio occlusodistal palatal (MODP) preparation and 3 different computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restoration configurations. Three 3-dimensional finite element (FE) models designed with CAD/CAM ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with FE analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restoration were the lowest values relative to the other 2 restorations. Weibull analysis revealed that the individual failure probability in the endocrown enamel, dentin, and luting cement obviously diminished more than those for onlay and conventional crown restorations. The overall failure probabilities were 27.5%, 1%, and 1% for onlay, endocrown, and conventional crown restorations, respectively, in normal occlusal condition. This numeric investigation suggests that endocrown and conventional crown restorations for endodontically treated premolars with MODP preparation present similar longevity.
Gunsoy, S; Ulusoy, M
2016-01-01
The purpose of this study was to evaluate the internal and marginal fit of chrome cobalt (Co-Cr) crowns were fabricated with laser sintering, computer-aided design (CAD) and computer-aided manufacturing, and conventional methods. Polyamide master and working models were designed and fabricated. The models were initially designed with a software application for three-dimensional (3D) CAD (Maya, Autodesk Inc.). All models were fabricated models were produced by a 3D printer (EOSINT P380 SLS, EOS). 128 1-unit Co-Cr fixed dental prostheses were fabricated with four different techniques: Conventional lost wax method, milled wax with lost-wax method (MWLW), direct laser metal sintering (DLMS), and milled Co-Cr (MCo-Cr). The cement film thickness of the marginal and internal gaps was measured by an observer using a stereomicroscope after taking digital photos in ×24. Best fit rates according to mean and standard deviations of all measurements was in DLMS both in premolar (65.84) and molar (58.38) models in μm. A significant difference was found DLMS and the rest of fabrication techniques (P < 0.05). No significant difference was found between MCo-CR and MWLW in all fabrication techniques both in premolar and molar models (P > 0.05). DMLS was best fitting fabrication techniques for single crown based on the results.The best fit was found in marginal; the larger gap was found in occlusal.All groups were within the clinically acceptable misfit range.
A fast algorithm for computer aided collimation gamma camera (CACAO)
NASA Astrophysics Data System (ADS)
Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.
2000-08-01
The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.
Lee, Kai-Hui; Chiu, Pei-Ling
2013-10-01
Conventional visual cryptography (VC) suffers from a pixel-expansion problem, or an uncontrollable display quality problem for recovered images, and lacks a general approach to construct visual secret sharing schemes for general access structures. We propose a general and systematic approach to address these issues without sophisticated codebook design. This approach can be used for binary secret images in non-computer-aided decryption environments. To avoid pixel expansion, we design a set of column vectors to encrypt secret pixels rather than using the conventional VC-based approach. We begin by formulating a mathematic model for the VC construction problem to find the column vectors for the optimal VC construction, after which we develop a simulated-annealing-based algorithm to solve the problem. The experimental results show that the display quality of the recovered image is superior to that of previous papers.
Artefacts found in computed radiography.
Cesar, L J; Schueler, B A; Zink, F E; Daly, T R; Taubel, J P; Jorgenson, L L
2001-02-01
Artefacts on radiographic images are distracting and may compromise accurate diagnosis. Although most artefacts that occur in conventional radiography have become familiar, computed radiography (CR) systems produce artefacts that differ from those found in conventional radiography. We have encountered a variety of artefacts in CR images that were produced from four different models plate reader. These artefacts have been identified and traced to the imaging plate, plate reader, image processing software or laser printer or to operator error. Understanding the potential sources of CR artefacts will aid in identifying and resolving problems quickly and help prevent future occurrences.
Training Aids for Online Instruction: An Analysis.
ERIC Educational Resources Information Center
Guy, Robin Frederick
This paper describes a number of different types of training aids currently employed in online training: non-interactive audiovisual presentations; interactive computer-based aids; partially interactive aids based on recorded searches; print-based materials; and kits. The advantages and disadvantages of each type of aid are noted, and a table…
NASA Technical Reports Server (NTRS)
Fleming, P.
1985-01-01
A design technique is proposed for linear regulators in which a feedback controller of fixed structure is chosen to minimize an integral quadratic objective function subject to the satisfaction of integral quadratic constraint functions. Application of a non-linear programming algorithm to this mathematically tractable formulation results in an efficient and useful computer-aided design tool. Particular attention is paid to computational efficiency and various recommendations are made. Two design examples illustrate the flexibility of the approach and highlight the special insight afforded to the designer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pesaran, A.; Wierzbicki, T.; Sahraei, E.
The EV Everywhere Grand Challenge aims to produce plug-in electric vehicles as affordable and convenient for the American family as gasoline-powered vehicles by 2022. Among the requirements set by the challenge, electric vehicles must be as safe as conventional vehicles, and EV batteries must not lead to unsafe situations under abuse conditions. NREL's project started in October 2013, based on a proposal in response to the January 2013 DOE VTO FOA, with the goal of developing computer aided engineering tools to accelerate the development of safer lithium ion batteries.
Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement.
Kameyama, Atsushi; Bonroy, Kim; Elsen, Caroline; Lührs, Anne-Katrin; Suyama, Yuji; Peumans, Marleen; Van Meerbeek, Bart; De Munck, Jan
2015-01-01
The aim of this study was to investigate bonding effectiveness in direct restorations. A two-step self-etch adhesive and a light-cure resin composite was compared with luting with a conventional dual-cure resin cement and a two-step etch and rinse adhesive. Class-I box-type cavities were prepared. Identical ceramic inlays were designed and fabricated with a computer-aided design/computer-aided manufacturing (CAD/CAM) device. The inlays were seated with Clearfil SE Bond/Clearfil AP-X (Kuraray Medical) or ExciTE F DSC/Variolink II (Ivoclar Vivadent), each by two operators (five teeth per group). The inlays were stored in water for one week at 37°C, whereafter micro-tensile bond strength testing was conducted. The micro-tensile bond strength of the direct composite was significantly higher than that from conventional luting, and was independent of the operator (P<0.0001). Pre-testing failures were only observed with the conventional method. High-power light-curing of a direct composite may be a viable alternative to luting lithium disilicate glass-ceramic CAD/CAM restorations.
Computer aided diagnosis of diabetic foot using infrared thermography: A review.
Adam, Muhammad; Ng, Eddie Y K; Tan, Jen Hong; Heng, Marabelle L; Tong, Jasper W K; Acharya, U Rajendra
2017-12-01
Diabetes mellitus (DM) is a chronic metabolic disorder that requires regular medical care to prevent severe complications. The elevated blood glucose level affects the eyes, blood vessels, nerves, heart, and kidneys after the onset. The affected blood vessels (usually due to atherosclerosis) may lead to insufficient blood circulation particularly in the lower extremities and nerve damage (neuropathy), which can result in serious foot complications. Hence, an early detection and treatment can prevent foot complications such as ulcerations and amputations. Clinicians often assess the diabetic foot for sensory deficits with clinical tools, and the resulting foot severity is often manually evaluated. The infrared thermography is a fast, nonintrusive and non-contact method which allows the visualization of foot plantar temperature distribution. Several studies have proposed infrared thermography-based computer aided diagnosis (CAD) methods for diabetic foot. Among them, the asymmetric temperature analysis method is more superior, as it is easy to implement, and yielded satisfactory results in most of the studies. In this paper, the diabetic foot, its pathophysiology, conventional assessments methods, infrared thermography and the different infrared thermography-based CAD analysis methods are reviewed. Copyright © 2017 Elsevier Ltd. All rights reserved.
2017-08-08
Usability Studies In Virtual And Traditional Computer Aided Design Environments For Fault Identification Dr. Syed Adeel Ahmed, Xavier University...virtual environment with wand interfaces compared directly with a workstation non-stereoscopic traditional CAD interface with keyboard and mouse. In...the differences in interaction when compared with traditional human computer interfaces. This paper provides analysis via usability study methods
Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams
Bennamoun, Mohammed
2014-01-01
In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888
A Computer-Aided Distinction Method of Borderline Grades of Oral Cancer
NASA Astrophysics Data System (ADS)
Sami, Mustafa M.; Saito, Masahisa; Muramatsu, Shogo; Kikuchi, Hisakazu; Saku, Takashi
We have developed a new computer-aided diagnostic system for differentiating oral borderline malignancies in hematoxylin-eosin stained microscopic images. Epithelial dysplasia and carcinoma in-situ (CIS) of oral mucosa are two different borderline grades similar to each other, and it is difficult to distinguish between them. A new image processing and analysis method has been applied to a variety of histopathological features and shows the possibility for differentiating the oral cancer borderline grades automatically. The method is based on comparing the drop-shape similarity level in a particular manually selected pair of neighboring rete ridges. It was found that the considered similarity level in dysplasia was higher than those in epithelial CIS, of which pathological diagnoses were conventionally made by pathologists. The developed image processing method showed a good promise for the computer-aided pathological assessment of oral borderline malignancy differentiation in clinical practice.
Analysis of adventitious lung sounds originating from pulmonary tuberculosis.
Becker, K W; Scheffer, C; Blanckenberg, M M; Diacon, A H
2013-01-01
Tuberculosis is a common and potentially deadly infectious disease, usually affecting the respiratory system and causing the sound properties of symptomatic infected lungs to differ from non-infected lungs. Auscultation is often ruled out as a reliable diagnostic technique for TB due to the random distribution of the infection and the varying severity of damage to the lungs. However, advancements in signal processing techniques for respiratory sounds can improve the potential of auscultation far beyond the capabilities of the conventional mechanical stethoscope. Though computer-based signal analysis of respiratory sounds has produced a significant body of research, there have not been any recent investigations into the computer-aided analysis of lung sounds associated with pulmonary Tuberculosis (TB), despite the severity of the disease in many countries. In this paper, respiratory sounds were recorded from 14 locations around the posterior and anterior chest walls of healthy volunteers and patients infected with pulmonary TB. The most significant signal features in both the time and frequency domains associated with the presence of TB, were identified by using the statistical overlap factor (SOF). These features were then employed to train a neural network to automatically classify the auscultation recordings into their respective healthy or TB-origin categories. The neural network yielded a diagnostic accuracy of 73%, but it is believed that automated filtering of the noise in the clinics, more training samples and perhaps other signal processing methods can improve the results of future studies. This work demonstrates the potential of computer-aided auscultation as an aid for the diagnosis and treatment of TB.
NASA Technical Reports Server (NTRS)
Hoffer, R. M.
1975-01-01
Skylab data were obtained over a mountainous test site containing a complex association of cover types and rugged topography. The application of computer-aided analysis techniques to the multispectral scanner data produced a number of significant results. Techniques were developed to digitally overlay topographic data (elevation, slope, and aspect) onto the S-192 MSS data to provide a method for increasing the effectiveness and accuracy of computer-aided analysis techniques for cover type mapping. The S-192 MSS data were analyzed using computer techniques developed at Laboratory for Applications of Remote Sensing (LARS), Purdue University. Land use maps, forest cover type maps, snow cover maps, and area tabulations were obtained and evaluated. These results compared very well with information obtained by conventional techniques. Analysis of the spectral characteristics of Skylab data has conclusively proven the value of the middle infrared portion of the spectrum (about 1.3-3.0 micrometers), a wavelength region not previously available in multispectral satellite data.
Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report.
Oh, Ji-Hyeon; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho
2017-12-01
The purpose of this article was to describe a fully digital workflow used to perform computer-guided flapless implant placement in an edentulous patient without the use of conventional impressions, models, or a radiographic guide. Digital data for the workflow were acquired using an intraoral scanner and cone-beam computed tomography (CBCT). The image fusion of the intraoral scan data and CBCT data was performed by matching resin markers placed in the patient's mouth. The definitive digital data were used to design a prosthetically driven implant position, surgical template, and computer-aided design and computer-aided manufacturing fabricated fixed dental prosthesis. The authors believe this is the first published case describing such a technique in computer-guided flapless implant surgery for edentulous patients. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.
Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L
2013-01-01
Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.
Lee, M-Y; Chang, C-C; Ku, Y C
2008-01-01
Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.
Do CAD/CAM dentures really release less monomer than conventional dentures?
Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert
2017-06-01
Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.
NASA Astrophysics Data System (ADS)
Cheng, Jie-Zhi; Ni, Dong; Chou, Yi-Hong; Qin, Jing; Tiu, Chui-Mei; Chang, Yeun-Chung; Huang, Chiun-Sheng; Shen, Dinggang; Chen, Chung-Ming
2016-04-01
This paper performs a comprehensive study on the deep-learning-based computer-aided diagnosis (CADx) for the differential diagnosis of benign and malignant nodules/lesions by avoiding the potential errors caused by inaccurate image processing results (e.g., boundary segmentation), as well as the classification bias resulting from a less robust feature set, as involved in most conventional CADx algorithms. Specifically, the stacked denoising auto-encoder (SDAE) is exploited on the two CADx applications for the differentiation of breast ultrasound lesions and lung CT nodules. The SDAE architecture is well equipped with the automatic feature exploration mechanism and noise tolerance advantage, and hence may be suitable to deal with the intrinsically noisy property of medical image data from various imaging modalities. To show the outperformance of SDAE-based CADx over the conventional scheme, two latest conventional CADx algorithms are implemented for comparison. 10 times of 10-fold cross-validations are conducted to illustrate the efficacy of the SDAE-based CADx algorithm. The experimental results show the significant performance boost by the SDAE-based CADx algorithm over the two conventional methods, suggesting that deep learning techniques can potentially change the design paradigm of the CADx systems without the need of explicit design and selection of problem-oriented features.
Cheng, Jie-Zhi; Ni, Dong; Chou, Yi-Hong; Qin, Jing; Tiu, Chui-Mei; Chang, Yeun-Chung; Huang, Chiun-Sheng; Shen, Dinggang; Chen, Chung-Ming
2016-04-15
This paper performs a comprehensive study on the deep-learning-based computer-aided diagnosis (CADx) for the differential diagnosis of benign and malignant nodules/lesions by avoiding the potential errors caused by inaccurate image processing results (e.g., boundary segmentation), as well as the classification bias resulting from a less robust feature set, as involved in most conventional CADx algorithms. Specifically, the stacked denoising auto-encoder (SDAE) is exploited on the two CADx applications for the differentiation of breast ultrasound lesions and lung CT nodules. The SDAE architecture is well equipped with the automatic feature exploration mechanism and noise tolerance advantage, and hence may be suitable to deal with the intrinsically noisy property of medical image data from various imaging modalities. To show the outperformance of SDAE-based CADx over the conventional scheme, two latest conventional CADx algorithms are implemented for comparison. 10 times of 10-fold cross-validations are conducted to illustrate the efficacy of the SDAE-based CADx algorithm. The experimental results show the significant performance boost by the SDAE-based CADx algorithm over the two conventional methods, suggesting that deep learning techniques can potentially change the design paradigm of the CADx systems without the need of explicit design and selection of problem-oriented features.
Cheng, Jie-Zhi; Ni, Dong; Chou, Yi-Hong; Qin, Jing; Tiu, Chui-Mei; Chang, Yeun-Chung; Huang, Chiun-Sheng; Shen, Dinggang; Chen, Chung-Ming
2016-01-01
This paper performs a comprehensive study on the deep-learning-based computer-aided diagnosis (CADx) for the differential diagnosis of benign and malignant nodules/lesions by avoiding the potential errors caused by inaccurate image processing results (e.g., boundary segmentation), as well as the classification bias resulting from a less robust feature set, as involved in most conventional CADx algorithms. Specifically, the stacked denoising auto-encoder (SDAE) is exploited on the two CADx applications for the differentiation of breast ultrasound lesions and lung CT nodules. The SDAE architecture is well equipped with the automatic feature exploration mechanism and noise tolerance advantage, and hence may be suitable to deal with the intrinsically noisy property of medical image data from various imaging modalities. To show the outperformance of SDAE-based CADx over the conventional scheme, two latest conventional CADx algorithms are implemented for comparison. 10 times of 10-fold cross-validations are conducted to illustrate the efficacy of the SDAE-based CADx algorithm. The experimental results show the significant performance boost by the SDAE-based CADx algorithm over the two conventional methods, suggesting that deep learning techniques can potentially change the design paradigm of the CADx systems without the need of explicit design and selection of problem-oriented features. PMID:27079888
NASA Technical Reports Server (NTRS)
Kolb, Mark A.
1990-01-01
Originally, computer programs for engineering design focused on detailed geometric design. Later, computer programs for algorithmically performing the preliminary design of specific well-defined classes of objects became commonplace. However, due to the need for extreme flexibility, it appears unlikely that conventional programming techniques will prove fruitful in developing computer aids for engineering conceptual design. The use of symbolic processing techniques, such as object-oriented programming and constraint propagation, facilitate such flexibility. Object-oriented programming allows programs to be organized around the objects and behavior to be simulated, rather than around fixed sequences of function- and subroutine-calls. Constraint propagation allows declarative statements to be understood as designating multi-directional mathematical relationships among all the variables of an equation, rather than as unidirectional assignments to the variable on the left-hand side of the equation, as in conventional computer programs. The research has concentrated on applying these two techniques to the development of a general-purpose computer aid for engineering conceptual design. Object-oriented programming techniques are utilized to implement a user-extensible database of design components. The mathematical relationships which model both geometry and physics of these components are managed via constraint propagation. In addition, to this component-based hierarchy, special-purpose data structures are provided for describing component interactions and supporting state-dependent parameters. In order to investigate the utility of this approach, a number of sample design problems from the field of aerospace engineering were implemented using the prototype design tool, Rubber Airplane. The additional level of organizational structure obtained by representing design knowledge in terms of components is observed to provide greater convenience to the program user, and to result in a database of engineering information which is easier both to maintain and to extend.
Spatial Visualization by Isometric View
ERIC Educational Resources Information Center
Yue, Jianping
2007-01-01
Spatial visualization is a fundamental skill in technical graphics and engineering designs. From conventional multiview drawing to modern solid modeling using computer-aided design, visualization skills have always been essential for representing three-dimensional objects and assemblies. Researchers have developed various types of tests to measure…
Non-medical Uses of Computed Tomography (CT) and Nuclear Magnetic Resonance
Finding Aids dropdown arrow Site Map A-Z Index Menu Synopsis Non-medical Uses of Computed Tomography (CT materials characterizations, and to provide non-destructive evaluations for discovering flaws in parts presence and facilitate the recovery/extraction of oil, water, coal, and/or gas; and to provide non
Nozzles for Focusing Aerosol Particles
2009-10-01
Fabrication of the nozzle with the desired shape was accomplished using EDM technology. First, a copper tungsten electrode was turned on a CNC lathe . The...small (0.9-mm diameter). The external portions of the nozzles were machined in a more conventional manner using computer numerical control ( CNC ... lathes and milling machines running programs written by computer aided machining (CAM) software. The close tolerance of concentricity of the two
ERIC Educational Resources Information Center
Perilli, Viviana; Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Cassano, Germana; Cordiano, Noemi; Pinto, Katia; Minervini, Mauro G.; Oliva, Doretta
2012-01-01
This study assessed whether four patients with a diagnosis of Alzheimer's disease could make independent phone calls via a computer-aided telephone system. The study was carried out according to a non-concurrent multiple baseline design across participants. All participants started with baseline during which the telephone system was not available,…
Effect of Computer-Aided Instruction on Attitude and Achievement of Fifth Grade Math Students
ERIC Educational Resources Information Center
Shoemaker, Traci L.
2013-01-01
The purpose of this quasi-experimental non-equivalent control group study was to test theories of constructivism and motivation, along with research-based teaching practices of differentiating instruction and instructing within a child's Zone of Proximal Development, in measuring the effect of computer-aided instruction on fifth grade students'…
Comparison of retention between maxillary milled and conventional denture bases: A clinical study.
AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J
2017-02-01
Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Computer-Aided Evaluation of Forage Management: Forage Manager.
ERIC Educational Resources Information Center
Panciera, M. T.; And Others
1993-01-01
Presents the Forage Manager spreadsheet, developed as a forage management teaching tool to integrate agronomic, livestock, and cost data to demonstrate the impact of forage management on livestock production costs. Teaching applications, examples involving agronomic data and conventional agronomic evaluation, and limitations of the program are…
ERIC Educational Resources Information Center
Perilli, Viviana; Lancioni, Giulio E.; Laporta, Dominga; Paparella, Adele; Caffo, Alessandro O.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Oliva, Doretta
2013-01-01
This study extended the assessment of a computer-aided telephone system to enable five patients with a diagnosis of Alzheimer's disease to make phone calls independently. The patients were divided into two groups and exposed to intervention according to a non-concurrent multiple baseline design across groups. All patients started with baseline in…
The Use of Non-Specific Comments in a Conversation Aid for Non-Speaking People.
ERIC Educational Resources Information Center
Todman, John; Morrison, Zara
1995-01-01
TALK (Talk Aid using pre-Loaded Knowledge) is a computer system linked to a speech synthesizer which enables nonspeaking people to engage in real-time social conversation. TALK provides categories of general comments that can be used whenever a suitable specific response is unavailable. Results are reported of a study evaluating effectiveness of…
Product definition data interface
NASA Technical Reports Server (NTRS)
Birchfield, B.; Downey, P.
1984-01-01
The development and application of advanced Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology in aerospace industry is discussed. New CAD/CAM capabilities provide the engineer and production worker with tools to produce better products and significantly improve productivity. This technology is expanding in all phases of engineering and manufacturing with large potential for improvements in productivity. The integration of CAD and CAM systematically to insure maximum utility throughout the U.S. Aerospace Industry, its large community of supporting suppliers, and the Department of Defense aircraft overhaul and repair facilities is outlined. The need for a framework for exchange of digital product definition data, which serves the function of the conventional engineering drawing is emphasized.
Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.
Goo, Chui Ling; Tan, Keson Beng Choon
2017-01-01
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
2017-08-08
Usability Studies In Virtual And Traditional Computer Aided Design Environments For Spatial Awareness Dr. Syed Adeel Ahmed, Xavier University of...virtual environment with wand interfaces compared directly with a workstation non-stereoscopic traditional CAD interface with keyboard and mouse. In...navigate through a virtual environment. The wand interface provides a significantly improved means of interaction. This study quantitatively measures the
Advanced control techniques for teleoperation in earth orbit
NASA Technical Reports Server (NTRS)
Bejczy, A. K.; Brooks, T. L.
1980-01-01
Emerging teleoperation tasks in space invite advancements in teleoperator control technology. This paper briefly summarizes the generic issues related to earth orbital applications of teleoperators, and describes teleoperator control technology development work including visual and non-visual sensors and displays, kinesthetic feedback and computer-aided controls. Performance experiments were carried out using sensor and computer aided controls with promising results which are briefly summarized.
Roperto, Renato; Akkus, Anna; Akkus, Ozan; Lang, Lisa; Sousa-Neto, Manoel Damiao; Teich, Sorin; Porto, Thiago Soares
2016-01-01
The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer's instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.
Mehmood, Raja Majid; Lee, Hyo Jong
2017-01-01
Human computer interaction is a growing field in terms of helping people in their daily life to improve their living. Especially, people with some disability may need an interface which is more appropriate and compatible with their needs. Our research is focused on similar kinds of problems, such as students with some mental disorder or mood disruption problems. To improve their learning process, an intelligent emotion recognition system is essential which has an ability to recognize the current emotional state of the brain. Nowadays, in special schools, instructors are commonly use some conventional methods for managing special students for educational purposes. In this paper, we proposed a novel computer aided method for instructors at special schools where they can teach special students with the support of our system using wearable technologies. PMID:28208734
Dahl, Bjørn Einar; Rønold, Hans Jacob; Dahl, Jon E
2017-03-01
Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown. The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique. The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium. The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique. Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Science and Mathematics Access to Retain Talent Grant (National SMART Grant) Program Payment period... equipment, or non-loan processing or non-financial aid-related computer software at below market rental or...
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Computational neuropharmacology: dynamical approaches in drug discovery.
Aradi, Ildiko; Erdi, Péter
2006-05-01
Computational approaches that adopt dynamical models are widely accepted in basic and clinical neuroscience research as indispensable tools with which to understand normal and pathological neuronal mechanisms. Although computer-aided techniques have been used in pharmaceutical research (e.g. in structure- and ligand-based drug design), the power of dynamical models has not yet been exploited in drug discovery. We suggest that dynamical system theory and computational neuroscience--integrated with well-established, conventional molecular and electrophysiological methods--offer a broad perspective in drug discovery and in the search for novel targets and strategies for the treatment of neurological and psychiatric diseases.
ERIC Educational Resources Information Center
Kaplan, Abdullah; Özturk, Mesut; Ertör, Eren
2013-01-01
This study aims to compare computer-aided instruction, creative drama and traditional teaching methods in teaching of Integers to the seventh grade students. The study was conducted in a primary school with eighty-seven students (N=87) in a county of Agri, in spring term of academic year 2011-2012. A non equivalent control group quasi experimental…
Angelhed, J E; Bjurö, T I; Ejdebäck, J; Selin, K; Schlossman, D; Griffith, L S; Bergstrand, R; Vedin, A; Wilhelmsson, C
1984-01-01
A set of electrocardiographic criteria for the diagnosis of coronary artery disease was evaluated in two different groups of patients examined by computer aided 12 lead exercise electrocardiographic stress testing and coronary arteriography. One group consisted of patients with severe angina pectoris and the other of patients who had suffered a myocardial infarction three years before the study. Angiographically determined categories of patients could be identified with satisfactory precision by the electrocardiographic criteria under test in the patients with angina pectoris but not in those with infarction. A new method of classifying patients on the basis of data from coronary arteriography improved the correlation with ST segment analysis compared with conventional classification. PMID:6743432
Storm, J.B.
2004-01-01
The U.S. Geological Survey is computing continuous discharge of the Pearl River at the upper end of the Ross Barnett Reservoir near Jackson, Mississippi, using acoustic technology and conventional streamgaging methods. The computed inflow is posted "real-time" to the Mississippi District's web page where it can be monitored by the Pearl River Valley Water Supply District (PRVWSD) to aid in reservoir regulation. The use of this technology to determine discharge allows the PRVWSD to prepare for headwater flooding conditions ahead of time and adjust reservoir outflow accordingly. Hydraulic and acoustic problems inherent to this site have presented problems not normally encountered at a typical streamgaging site. Copyright ASCE 2004.
Virtual hospital--a computer-aided platform to evaluate the sense of direction.
Jiang, Ching-Fen; Li, Yuan-Shyi
2007-01-01
This paper presents a computer-aided platform, named Virtual Hospital (VH), to evaluate the wayfinding ability that is found impaired in senile people with early dementia. The development of the VH takes the advantage of virtual reality technology to make the evaluation of the sense of direction more convenient and accurate then the conventional way. A pilot study was carried out to test its feasibility in differentiating the sense of direction between different genders. The results with significant differences in the response time (p<0.05) and the pointing error (p<0.01) between genders suggest the potential of the VH for clinical uses. Further improvement on the human-machine interface is necessary to make it easy for geriatric people to use.
Ciocca, Leonardo; Fantini, Massimiliano; De Crescenzio, Francesca; Persiani, Franco; Scotti, Roberto
2010-01-01
A new protocol for making an immediate provisional eyeglasses-supported nasal prosthesis is presented that uses laser scanning, computer-aided design/computer-aided manufacturing procedures, and rapid prototyping techniques, reducing time and costs while increasing the quality of the final product. With this protocol, the eyeglasses were digitized, and the relative position of the nasal prosthesis was planned and evaluated in a virtual environment without any try-in appointment. This innovative method saves time, reduces costs, and restores the patient's aesthetic appearance after a disfiguration caused by ablation of the nasal pyramid better than conventional restoration methods. Moreover, the digital model of the designed nasal epithesis can be used to develop a definitive prosthesis anchored to osseointegrated craniofacial implants.
NASA Technical Reports Server (NTRS)
Erb, R. B.
1974-01-01
The Coastal Analysis Team of the Johnson Space Center conducted a 1-year investigation of ERTS-1 MSS data to determine its usefulness in coastal zone management. Galveston Bay, Texas, was the study area for evaluating both conventional image interpretation and computer-aided techniques. There was limited success in detecting, identifying and measuring areal extent of water bodies, turbidity zones, phytoplankton blooms, salt marshes, grasslands, swamps, and low wetlands using image interpretation techniques. Computer-aided techniques were generally successful in identifying these features. Aerial measurement of salt marshes accuracies ranged from 89 to 99 percent. Overall classification accuracy of all study sites was 89 percent for Level 1 and 75 percent for Level 2.
Mapping soil features from multispectral scanner data
NASA Technical Reports Server (NTRS)
Kristof, S. J.; Zachary, A. L.
1974-01-01
In being able to identify quickly gross variations in soil features, the computer-aided classification of multispectral scanner data can be an effective aid to soil surveying. Variations in soil tone are easily seen as well as variations in features related to soil tone, e.g., drainage patterns and organic matter content. Changes in surface texture also affect the reflectance properties of soils. Inasmuch as conventional soil classes are based on both surface and subsurface soil characteristics, the technique described here can be expected only to augment and not replace traditional soil mapping.
Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed
2017-01-01
Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.
NASA Astrophysics Data System (ADS)
Nugraha, Muhamad Gina; Kaniawati, Ida; Rusdiana, Dadi; Kirana, Kartika Hajar
2016-02-01
Among the purposes of physics learning at high school is to master the physics concepts and cultivate scientific attitude (including critical attitude), develop inductive and deductive reasoning skills. According to Ennis et al., inductive and deductive reasoning skills are part of critical thinking. Based on preliminary studies, both of the competence are lack achieved, it is seen from student learning outcomes is low and learning processes that are not conducive to cultivate critical thinking (teacher-centered learning). One of learning model that predicted can increase mastery concepts and train CTS is inquiry learning model aided computer simulations. In this model, students were given the opportunity to be actively involved in the experiment and also get a good explanation with the computer simulations. From research with randomized control group pretest-posttest design, we found that the inquiry learning model aided computer simulations can significantly improve students' mastery concepts than the conventional (teacher-centered) method. With inquiry learning model aided computer simulations, 20% of students have high CTS, 63.3% were medium and 16.7% were low. CTS greatly contribute to the students' mastery concept with a correlation coefficient of 0.697 and quite contribute to the enhancement mastery concept with a correlation coefficient of 0.603.
Tan, Maxine; Aghaei, Faranak; Wang, Yunzhi; Zheng, Bin
2017-01-01
The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and structural similarity features computed from all four full-field digital mammography (FFDM) images of the craniocaudal (CC) and mediolateral oblique (MLO) views by using a modified fast and accurate sequential floating forward selection feature selection algorithm. Selected features were then applied to a “scoring fusion” artificial neural network (ANN) classification scheme to produce a final case based risk score. In the second approach, we combined the case based risk score with the conventional lesion based scores of a conventional lesion based CAD scheme using a new adaptive cueing method that is integrated with the case based risk scores. We evaluated our methods using a ten-fold cross-validation scheme on 924 cases (476 cancer and 448 recalled or negative), whereby each case had all four images from the CC and MLO views. The area under the receiver operating characteristic curve was AUC = 0.793±0.015 and the odds ratio monotonically increased from 1 to 37.21 as CAD-generated case based detection scores increased. Using the new adaptive cueing method, the region based and case based sensitivities of the conventional CAD scheme at a false positive rate of 0.71 per image increased by 2.4% and 0.8%, respectively. The study demonstrated that supplementary information can be derived by computing global mammographic density image features to improve CAD-cueing performance on the suspicious mammographic lesions. PMID:27997380
Li, Baofeng; Chen, Bei; Zhang, Ying; Wang, Xinyu; Wang, Fei; Xia, Hong; Yin, Qingshui
2016-01-01
Computed tomography (CT) scan with three-dimensional (3D) reconstruction has been used to evaluate complex fractures in pre-operative planning. In this study, rapid prototyping of a life-size model based on 3D reconstructions including bone and vessel was applied to evaluate the feasibility and prospect of these new technologies in surgical therapy of Tile C pelvic fractures by observing intra- and perioperative outcomes. The authors conducted a retrospective study on a group of 157 consecutive patients with Tile C pelvic fractures. Seventy-six patients were treated with conventional pre-operative preparation (A group) and 81 patients were treated with the help of computer-aided angiography and rapid prototyping technology (B group). Assessment of the two groups considered the following perioperative parameters: length of surgical procedure, intra-operative complications, intra- and postoperative blood loss, postoperative pain, postoperative nausea and vomiting (PONV), length of stay, and type of discharge. The two groups were homogeneous when compared in relation to mean age, sex, body weight, injury severity score, associated injuries and pelvic fracture severity score. Group B was performed in less time (105 ± 19 minutes vs. 122 ± 23 minutes) and blood loss (31.0 ± 8.2 g/L vs. 36.2 ± 7.4 g/L) compared with group A. Patients in group B experienced less pain (2.5 ± 2.3 NRS score vs. 2.8 ± 2.0 NRS score), and PONV affected only 8 % versus 10 % of cases. Times to discharge were shorter (7.8 ± 2.0 days vs. 10.2 ± 3.1 days) in group B, and most of patients were discharged to home. In our study, patients of Tile C pelvic fractures treated with computer-aided angiography and rapid prototyping technology had a better perioperative outcome than patients treated with conventional pre-operative preparation. Further studies are necessary to investigate the advantages in terms of clinical results in the short and long run.
Challe, Joyce F X; Price, Lisa Leimar
2009-12-18
Tanzania is a wild orchid biodiversity hotspot and has a high prevalence of HIV/AIDS. The wild orchids in the study are endemic and protected by the Convention on International Trade in Endangered Species. Every year, however, between 2.2 and 4.1 million orchid plants consumed in Zambia are estimated as originating from Tanzania. This research examines the differences between HIV/AIDS wild edible orchid gatherers and non-HIV/AIDS gatherers with regards to the frequency of gathering, salience in naming the various orchids, gathering knowledge acquisition and perceptions regarding the current state of abundance of the edible species. Data was collected through interviews with 224 individuals in the Makete District of Tanzania close to the boarder of Zambia. Free-listings were conducted and Sutrup's Cultural Significance Index (CSI) constructed. The independent t-test was used to compare the differences in gathering frequencies between affected and non-affected gatherers. A multiple comparison of the 4 subgroups (affected adults and children, and non-affected adults and children) in gathering frequencies was done with a one way ANOVA test and its post hoc test. To examine the difference between affected and non-affected gatherers difference in source of gathering knowledge, a chi square test was run. Forty two vernacular names of gathered orchid species were mentioned corresponding to 7 botanical species belongs to genera Disa, Satyrium, Habenaria, Eulophia and Roeperocharis. Ninety-seven percent of HIV/AIDS affected households state that orchid gathering is their primary economic activity compared to non-HIV/AIDS affected households at 9.7 percent. The HIV/AIDS affected gathered significantly more often than the non-affected. AIDS orphans, however, gathered most frequently. Gatherers perceive a decreasing trend of abundance of 6 of the 7 species. Gathering activities were mainly performed in age based peer groups. The results revealed a significant difference between affected and non-affected individuals in terms of their source of gathering knowledge. HIV/AIDS is related to increased reliance on the natural environment. This appears even more so for the most vulnerable, the AIDS orphaned children followed by HIV/AIDS widows.
Biologically inspired binaural hearing aid algorithms: Design principles and effectiveness
NASA Astrophysics Data System (ADS)
Feng, Albert
2002-05-01
Despite rapid advances in the sophistication of hearing aid technology and microelectronics, listening in noise remains problematic for people with hearing impairment. To solve this problem two algorithms were designed for use in binaural hearing aid systems. The signal processing strategies are based on principles in auditory physiology and psychophysics: (a) the location/extraction (L/E) binaural computational scheme determines the directions of source locations and cancels noise by applying a simple subtraction method over every frequency band; and (b) the frequency-domain minimum-variance (FMV) scheme extracts a target sound from a known direction amidst multiple interfering sound sources. Both algorithms were evaluated using standard metrics such as signal-to-noise-ratio gain and articulation index. Results were compared with those from conventional adaptive beam-forming algorithms. In free-field tests with multiple interfering sound sources our algorithms performed better than conventional algorithms. Preliminary intelligibility and speech reception results in multitalker environments showed gains for every listener with normal or impaired hearing when the signals were processed in real time with the FMV binaural hearing aid algorithm. [Work supported by NIH-NIDCD Grant No. R21DC04840 and the Beckman Institute.
ERIC Educational Resources Information Center
Ozkan, Aysen; Yildirim, Kemal
2016-01-01
Problem Statement: Drafting course is essential for students in the design disciplines for becoming more organized and for complying with standards in the educational system. Drafting knowledge is crucial, both for comprehension of the issues and for the implementation phase. In any design project, drafting performance and success are as important…
Choosing a Microcomputer for Use as a Teaching Aid.
ERIC Educational Resources Information Center
Visniesky, Cheryl; Hocking, Joan
A step-by-step guide to the selection of a microcomputer system is provided for educators having made the decision to implement computer-assisted instruction. The first step is to clarify reasons for using a microcomputer rather than conventional instructional materials. Next, the degree of use (e.g., types of courses and number of departments…
Uranium Glass: A Glowing Alternative to Conventional Sources of Radioactivity
ERIC Educational Resources Information Center
Boot, Roeland
2017-01-01
There is a relatively simple way of using radioactive material in classroom experiments: uranium glass, which provides teachers with a suitable substance. By using the right computer software and a radiation sensor, it can be demonstrated that uranium glass emits radiation at a greater rate than the background radiation and with the aid of UV…
1986-07-28
computation the lack of availability of goods, with the aid of an econometric model of the 4-person wage earner household (FRG consumption...substantially reducing the specific consumption of en- ergy, raw materials, and intermediate products per unit of national income . Cooperation conventions...of income , availability of goods, etc. Without a doubt, such differences impair the indicative value of consumer parities. However, the differences
Green functions of graphene: An analytic approach
NASA Astrophysics Data System (ADS)
Lawlor, James A.; Ferreira, Mauro S.
2015-04-01
In this article we derive the lattice Green Functions (GFs) of graphene using a Tight Binding Hamiltonian incorporating both first and second nearest neighbour hoppings and allowing for a non-orthogonal electron wavefunction overlap. It is shown how the resulting GFs can be simplified from a double to a single integral form to aid computation, and that when considering off-diagonal GFs in the high symmetry directions of the lattice this single integral can be approximated very accurately by an algebraic expression. By comparing our results to the conventional first nearest neighbour model commonly found in the literature, it is apparent that the extended model leads to a sizeable change in the electronic structure away from the linear regime. As such, this article serves as a blueprint for researchers who wish to examine quantities where these considerations are important.
Su, Ting-Shu; Sun, Jian
2016-09-01
For 20 years, the intraoral digital impression technique has been applied to the fabrication of computer aided design and computer aided manufacturing (CAD-CAM) fixed dental prostheses (FDPs). Clinical fit is one of the main determinants of the success of an FDP. Studies of the clinical fit of 3-unit ceramic FDPs made by means of a conventional impression versus a digital impression technology are limited. The purpose of this in vitro study was to evaluate and compare the internal fit and marginal fit of CAD-CAM, 3-unit ceramic FDP frameworks fabricated from an intraoral digital impression and a conventional impression. A standard model was designed for a prepared maxillary left canine and second premolar and missing first premolar. The model was scanned with an intraoral digital scanner, exporting stereolithography (STL) files as the experimental group (digital group). The model was used to fabricate 10 stone casts that were scanned with an extraoral scanner, exporting STL files to a computer connected to the scanner as the control group (conventional group). The STL files were used to produce zirconia FDP frameworks with CAD-CAM. These frameworks were seated on the standard model and evaluated for marginal and internal fit. Each framework was segmented into 4 sections per abutment teeth, resulting in 8 sections per framework, and was observed using optical microscopy with ×50 magnification. Four measurement points were selected on each section as marginal discrepancy (P1), mid-axial wall (P2), axio-occusal edge (P3), and central-occlusal point (P4). Mean marginal fit values of the digital group (64 ±16 μm) were significantly smaller than those of the conventional group (76 ±18 μm) (P<.05). The mean internal fit values of the digital group (111 ±34 μm) were significantly smaller than those of the conventional group (132 ±44 μm) (P<.05). CAD-CAM 3-unit zirconia FDP frameworks fabricated from intraoral digital and conventional impressions showed clinically acceptable marginal and internal fit. The marginal and internal fit of frameworks fabricated from the intraoral digital impression system were better than those fabricated from conventional impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Computer-Aided Engineering | Wind | NREL
Computes coupled section properties of composite blades for beam-type models Inputs are the airfoil shape approach BModes Computes coupled mode shapes and frequencies of blades and towers Inputs are the boundary -Coordinate transformation Transforms the cumulative dynamics of spinning rotor blades into the non-rotating
Azuma, Masaki; Yanagawa, Toru; Ishibashi-Kanno, Naomi; Uchida, Fumihiko; Ito, Takaaki; Yamagata, Kenji; Hasegawa, Shogo; Sasaki, Kaoru; Adachi, Koji; Tabuchi, Katsuhiko; Sekido, Mitsuru; Bukawa, Hiroki
2014-10-23
Recently, medical rapid prototyping (MRP) models, fabricated with computer-aided design and computer-aided manufacture (CAD/CAM) techniques, have been applied to reconstructive surgery in the treatment of head and neck cancers. Here, we tested the use of preoperatively manufactured reconstruction plates, which were produced using MRP models. The clinical efficacy and esthetic outcome of using these products in mandibular reconstruction was evaluated. A series of 28 patients with malignant oral tumors underwent unilateral segmental resection of the mandible and simultaneous mandibular reconstruction. Twelve patients were treated with prebent reconstruction plates that were molded to MRP mandibular models designed with CAD/CAM techniques and fabricated on a combined powder bed and inkjet head three-dimensional printer. The remaining 16 patients were treated using conventional reconstruction methods. The surgical and esthetic outcomes of the two groups were compared by imaging analysis using post-operative panoramic tomography. The mandibular symmetry in patients receiving the MRP-model-based prebent plates was significantly better than that in patients receiving conventional reconstructive surgery. Patients with head and neck cancer undergoing reconstructive surgery using a prebent reconstruction plate fabricated according to an MRP mandibular model showed improved mandibular contour compared to patients undergoing conventional mandibular reconstruction. Thus, use of this new technology for mandibular reconstruction results in an improved esthetic outcome with the potential for improved quality of life for patients.
NASA Astrophysics Data System (ADS)
Liu, Carol Y. B.; Luk, David C. K.; Zhou, Kany S. Y.; So, Bryan M. K.; Louie, Derek C. H.
2015-03-01
Due to the increasing incidences of malignant melanoma, there is a rising demand for assistive technologies for its early diagnosis and improving the survival rate. The commonly used visual screening method is with limited accuracy as the early phase of melanoma shares many clinical features with an atypical nevus, while conventional dermoscopes are not user-friendly in terms of setup time and operations. Therefore, the development of an intelligent and handy system to assist the accurate screening and long-term monitoring of melanocytic skin lesions is crucial for early diagnosis and prevention of melanoma. In this paper, an advanced design of non-invasive and non-radioactive dermoscopy system was reported. Computer-aided simulations were conducted for optimizing the optical design and uniform illumination distribution. Functional prototype and the software system were further developed, which could enable image capturing at 10x amplified and general modes, convenient data transmission, analysis of dermoscopic features (e.g., asymmetry, border irregularity, color, diameter and dermoscopic structure) for assisting the early detection of melanoma, extract patient information (e.g. code, lesion location) and integrate with dermoscopic images, thus further support long term monitoring of diagnostic analysis results. A clinical trial study was further conducted on 185 Chinese children (0-18 years old). The results showed that for all subjects, skin conditions diagnosed based on the developed system accurately confirmed the diagnoses by conventional clinical procedures. Besides, clinical analysis on dermoscopic features and a potential standard approach by the developed system to support identifying specific melanocytic patterns for dermoscopic examination in Chinese children were also reported.
Nageswari, K Sri; Malhotra, Anita S; Kapoor, Nandini; Kaur, Gurjit
2004-12-01
Modern teaching trends in medical education exhibit a paradigm shift from the conventional classroom teaching methods adopted in the past to nonconventional teaching aids so as to encourage interactive forms of learning in medical students through active participation and integrative reasoning where the relationship of the teacher and the taught has undergone tremendous transformation. Some of the nonconventional teaching methods adopted at our department are learning through active participation by the students through computer-assisted learning (CD-ROMs), Web-based learning (undergraduate projects), virtual laboratories, seminars, audiovisual aids (video-based demonstrations), and "physioquiz."
Computer aided system engineering for space construction
NASA Technical Reports Server (NTRS)
Racheli, Ugo
1989-01-01
This viewgraph presentation covers the following topics. Construction activities envisioned for the assembly of large platforms in space (as well as interplanetary spacecraft and bases on extraterrestrial surfaces) require computational tools that exceed the capability of conventional construction management programs. The Center for Space Construction is investigating the requirements for new computational tools and, at the same time, suggesting the expansion of graduate and undergraduate curricula to include proficiency in Computer Aided Engineering (CAE) though design courses and individual or team projects in advanced space systems design. In the center's research, special emphasis is placed on problems of constructability and of the interruptability of planned activity sequences to be carried out by crews operating under hostile environmental conditions. The departure point for the planned work is the acquisition of the MCAE I-DEAS software, developed by the Structural Dynamics Research Corporation (SDRC), and its expansion to the level of capability denoted by the acronym IDEAS**2 currently used for configuration maintenance on Space Station Freedom. In addition to improving proficiency in the use of I-DEAS and IDEAS**2, it is contemplated that new software modules will be developed to expand the architecture of IDEAS**2. Such modules will deal with those analyses that require the integration of a space platform's configuration with a breakdown of planned construction activities and with a failure modes analysis to support computer aided system engineering (CASE) applied to space construction.
Differences in muscle load between computer and non-computer work among office workers.
Richter, J M; Mathiassen, S E; Slijper, H P; Over, E A B; Frens, M A
2009-12-01
Introduction of more non-computer tasks has been suggested to increase exposure variation and thus reduce musculoskeletal complaints (MSC) in computer-intensive office work. This study investigated whether muscle activity did, indeed, differ between computer and non-computer activities. Whole-day logs of input device use in 30 office workers were used to identify computer and non-computer work, using a range of classification thresholds (non-computer thresholds (NCTs)). Exposure during these activities was assessed by bilateral electromyography recordings from the upper trapezius and lower arm. Contrasts in muscle activity between computer and non-computer work were distinct but small, even at the individualised, optimal NCT. Using an average group-based NCT resulted in less contrast, even in smaller subgroups defined by job function or MSC. Thus, computer activity logs should be used cautiously as proxies of biomechanical exposure. Conventional non-computer tasks may have a limited potential to increase variation in muscle activity during computer-intensive office work.
Kitayama, Shuzo; Nasser, Nasser A; Pilecki, Peter; Wilson, Ron F; Nikaido, Toru; Tagami, Junji; Watson, Timothy F; Foxton, Richard M
2011-05-01
To evaluate the effect of resin coating and occlusal loading on microleakage of class II computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restorations. Molars were prepared for an mesio-occlusal-distal (MOD) inlay and were divided into two groups: non-coated (controls); and resin-coated, in which the cavity was coated with a combination of a dentin bonding system (Clearfil Protect Bond) and a flowable resin composite (Clearfil Majesty Flow). Ceramic inlays were fabricated using the CAD/CAM technique (CEREC 3) and cemented with resin cement (Clearfil Esthetic Cement). After 24 h of water storage, the restored teeth in each group were divided into two subgroups: unloaded or loaded with an axial force of 80 N at a rate of 2.5 cycles/s for 250,000 cycles while stored in water. After immersion in 0.25% Rhodamine B solution, the teeth were sectioned bucco-lingually at the mesial and distal boxes. Tandem scanning confocal microscopy (TSM) was used for evaluation of microleakage. The locations of the measurements were assigned to the cavity walls and floor. Loading did not have a significant effect on microleakage in either the resin-coated or non-coated group. Resin coating significantly reduced microleakage regardless of loading. The cavity floor exhibited greater microleakage compared to the cavity wall. TSM observation also revealed that microleakage at the enamel surface was minimal regardless of resin coating. In contrast, non-coated dentin showed extensive leakage, whereas resin-coated dentin showed decreased leakage. Resin coating with a combination of a dentin-bonding system and a flowable resin composite may be indicated prior to impression-taking when restoring teeth with CAD/CAM ceramic inlays in order to reduce microleakage at the tooth-resin interface.
Superpixel-based segmentation of glottal area from videolaryngoscopy images
NASA Astrophysics Data System (ADS)
Turkmen, H. Irem; Albayrak, Abdulkadir; Karsligil, M. Elif; Kocak, Ismail
2017-11-01
Segmentation of the glottal area with high accuracy is one of the major challenges for the development of systems for computer-aided diagnosis of vocal-fold disorders. We propose a hybrid model combining conventional methods with a superpixel-based segmentation approach. We first employed a superpixel algorithm to reveal the glottal area by eliminating the local variances of pixels caused by bleedings, blood vessels, and light reflections from mucosa. Then, the glottal area was detected by exploiting a seeded region-growing algorithm in a fully automatic manner. The experiments were conducted on videolaryngoscopy images obtained from both patients having pathologic vocal folds as well as healthy subjects. Finally, the proposed hybrid approach was compared with conventional region-growing and active-contour model-based glottal area segmentation algorithms. The performance of the proposed method was evaluated in terms of segmentation accuracy and elapsed time. The F-measure, true negative rate, and dice coefficients of the hybrid method were calculated as 82%, 93%, and 82%, respectively, which are superior to the state-of-art glottal-area segmentation methods. The proposed hybrid model achieved high success rates and robustness, making it suitable for developing a computer-aided diagnosis system that can be used in clinical routines.
Zhang, Yuan Z; Lu, Sheng; Zhang, Hui Q; Jin, Zhong M; Zhao, Jian M; Huang, Jian; Zhang, Zhi F
2016-10-01
The success of total knee arthroplasty (TKA) depends on many factors. The position of a prosthesis is vitally important. The purpose of the present study was to evaluate the value of a computer-aided establishing lower extremity mechanical axis in TKA using digital technology. A total of 36 cases of patients with TKA were randomly divided into the computer-aided design of navigation template group (NT) and conventional intramedullary positioning group (CIP). Three-dimensional (3D) CT scanning images of the hip, knee, and ankle were obtained in NT group. X-ray images and CT scans were transferred into the 3D reconstruction software. A 3D bone model of the hip, knee, ankle, as well as the modified loading, was reconstructed and saved in a stereolithographic format. In the 3D reconstruction model, the mechanical axis of the lower limb was determined, and the navigational templates produced an accurate model using a rapid prototyping technique. The THA in CIP group was performed according to a routine operation. CT scans were performed postoperatively to evaluate the accuracy of the two TKA methods. The averaged operative time of the NT group procedures was [Formula: see text] min shorter than those of the conventional procedures ([Formula: see text] min). The coronal femoral angle, coronal tibial angle, posterior tibial slope were [Formula: see text], [Formula: see text], [Formula: see text] in NT group and [Formula: see text], [Formula: see text], [Formula: see text] in CIP group, respectively. Statistically significant group differences were found. The navigation template produced through mechanical axis of lower extremity may provide a relative accurate and simple method for TKA.
Hourd, Paul; Medcalf, Nicholas; Segal, Joel; Williams, David J
2015-01-01
Computer-aided 3D printing approaches to the industrial production of customized 3D functional living constructs for restoration of tissue and organ function face significant regulatory challenges. Using the manufacture of a customized, 3D-bioprinted nasal implant as a well-informed but hypothetical exemplar, we examine how these products might be regulated. Existing EU and USA regulatory frameworks do not account for the differences between 3D printing and conventional manufacturing methods or the ability to create individual customized products using mechanized rather than craft approaches. Already subject to extensive regulatory control, issues related to control of the computer-aided design to manufacture process and the associated software system chain present additional scientific and regulatory challenges for manufacturers of these complex 3D-bioprinted advanced combination products.
Barbosa, Daniel C; Roupar, Dalila B; Ramos, Jaime C; Tavares, Adriano C; Lima, Carlos S
2012-01-11
Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Kamble, Amit Pralhad; Pawar, Rohini Rangarao; Mattigatti, Sudha; Mangala, T. M.; Makandar, Saleem
2017-01-01
The purpose of these case reports is to emphasize the importance of knowledge regarding the root canal morphology and current diagnostic aids one should have as both of these important factors going to affect the prognosis of the endodontic treatment. These two case reports describe the maxillary and mandibular first molars with multiple canals. After clinical and radiographic diagnosis, additional help of cone-beam computed tomography (CBCT) of mandibular molar has been taken to evaluate the morphology and canal pattern; while maxillary molar was evaluated using CBCT scan to evaluate the canal configuration and obturation. In CBCT evaluation, the mandibular molar was diagnosed with six separated canals with three mesial and three distal canals and with radix paramolaris and radix entomolaris. The maxillary molar had five canals with three mesiobuccal (MB) canals. Both molars were instrumented with conventional hand and rotary file systems and obturated by conventional lateral compaction method. The axial images from CBCT show Vertucci Type VIII canal pattern in both roots of first mandibular molars and in MB root of maxillary first molar Sert and Bayirli Type XVIII canal configuration and no accessory canal in distobuccal and palatal root. With the recent innovations in diagnostic and operating aids, we can come across many variations in the root canal morphology of both mandibular and maxillary teeth, especially multi-rooted one (i.e., molars), and the knowledge of which leads to successful endodontic treatment with an excellent prognosis. PMID:29259367
NASA Technical Reports Server (NTRS)
Montegani, F. J.
1974-01-01
Methods of handling one-third-octave band noise data originating from the outdoor full-scale fan noise facility and the engine acoustic facility at the Lewis Research Center are presented. Procedures for standardizing, retrieving, extrapolating, and reporting these data are explained. Computer programs are given which are used to accomplish these and other noise data analysis tasks. This information is useful as background for interpretation of data from these facilities appearing in NASA reports and can aid data exchange by promoting standardization.
Farjood, Ehsan; Vojdani, Mahroo; Torabi, Kiyanoosh; Khaledi, Amir Ali Reza
2017-01-01
Given the limitations of conventional waxing, computer-aided design and computer-aided manufacturing (CAD-CAM) technologies have been developed as alternative methods of making patterns. The purpose of this in vitro study was to compare the marginal and internal fit of metal copings derived from wax patterns fabricated by rapid prototyping (RP) to those created by the conventional handmade technique. Twenty-four standardized brass dies were milled and divided into 2 groups (n=12) according to the wax pattern fabrication method. The CAD-RP group was assigned to the experimental group, and the conventional group to the control group. The cross-sectional technique was used to assess the marginal and internal discrepancies at 15 points on the master die by using a digital microscope. An independent t test was used for statistical analysis (α=.01). The CAD-RP group had a total mean (±SD) for absolute marginal discrepancy of 117.1 (±11.5) μm and a mean marginal discrepancy of 89.8 (±8.3) μm. The conventional group had an absolute marginal discrepancy 88.1 (±10.7) μm and a mean marginal discrepancy of 69.5 (±15.6) μm. The overall mean (±SD) of the total internal discrepancy, separately calculated as the axial internal discrepancy and occlusal internal discrepancy, was 95.9 (±8.0) μm for the CAD-RP group and 76.9 (±10.2) μm for the conventional group. The independent t test results showed significant differences between the 2 groups. The CAD-RP group had larger discrepancies at all measured areas than the conventional group, which was statistically significant (P<.01). Within the limitations of this in vitro study, the conventional method of wax pattern fabrication produced copings with better marginal and internal fit than the CAD-RP method. However, the marginal and internal fit for both groups were within clinically acceptable ranges. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Skariyachan, Sinosh; Narayan, Naik Sowmyalaxmi; Aggimath, Tejaswini S; Nagaraj, Sushmitha; Reddy, Monika S; Narayanappa, Rajeswari
2014-03-01
Streptococcus pyogenes is a notorious pathogenic bacterium which causes various human diseases ranging from localized infections to life threatening invasive diseases. Streptolysin-O (SLO), pore-forming thiol-activated cytolysin, is the major virulent factor for streptococcal infections. Present therapies against streptococcal infections are limited as most of the strains have developed multi-drug resistance to present generation of drugs. Hence, there is a need for alternative therapeutic substances. Structure based virtual screening is a novel platform to select lead molecules with better pharmacokinetic properties. The 3D structure of SLO (not available in native form), essential for such studies, was computationally generated and this homology model was used as probable drug target. Based on literature survey, several phytoligands from 25 medicinal plants were selected. Out of these, leads from 11 plants showed better pharmacokinetic properties. The best lead molecules were screened based on computer aided drug likeness and pharmacokinetic predictions. The inhibitory properties of selected herbal leads against SLO were studied by molecular docking. An in vitro assay was further carried out and variations observed were found to be significant (p<0.05). Antibiotic sensitivity testing was also performed with the clinical strain of Streptococcus pyogenes with conventional drugs. The clinical strain showed multi-drug resistance to conventional drugs. Our study revealed that numerous phytoligands have better inhibitory properties towards the toxin. We noticed that incorporation of selected herbal extracts in blood agar medium showed significant reduction in hemolysis (MIC 300μl/plate), indicating inhibition of SLO. Furthermore, the butanol extracts of selected herbal preparation based on computer aided screening showed significant inhibitory properties at 250 mcg/disc concentration. We also noticed that selected herbal formulations have better antimicrobial properties at MIC range of 300- 400μl. Hence, our study suggests that these herbal extracts have better inhibitory properties against the toxin as well as drug resistant Streptococcus pyogenes.
Automating software design system DESTA
NASA Technical Reports Server (NTRS)
Lovitsky, Vladimir A.; Pearce, Patricia D.
1992-01-01
'DESTA' is the acronym for the Dialogue Evolutionary Synthesizer of Turnkey Algorithms by means of a natural language (Russian or English) functional specification of algorithms or software being developed. DESTA represents the computer-aided and/or automatic artificial intelligence 'forgiving' system which provides users with software tools support for algorithm and/or structured program development. The DESTA system is intended to provide support for the higher levels and earlier stages of engineering design of software in contrast to conventional Computer Aided Design (CAD) systems which provide low level tools for use at a stage when the major planning and structuring decisions have already been taken. DESTA is a knowledge-intensive system. The main features of the knowledge are procedures, functions, modules, operating system commands, batch files, their natural language specifications, and their interlinks. The specific domain for the DESTA system is a high level programming language like Turbo Pascal 6.0. The DESTA system is operational and runs on an IBM PC computer.
Current State of Theoretical and Experimental Studies of the Voltage-Dependent Anion Channel (VDAC)
Noskov, Sergei Yu.; Rostovtseva, Tatiana K.; Chamberlin, Adam C.; Teijido, Oscar; Jiang, Wei; Bezrukov, Sergey M.
2016-01-01
Voltage-dependent anion channel (VDAC), the major channel of the mitochondrial outer membrane provides a controlled pathway for respiratory metabolites in and out of the mitochondria. In spite of the wealth of experimental data from structural, biochemical, and biophysical investigations, the exact mechanisms governing selective ion and metabolite transport, especially the role of titratable charged residues and interactions with soluble cytosolic proteins, remain hotly debated in the field. The computational advances hold a promise to provide a much sought-after solution to many of the scientific disputes around solute and ion transport through VDAC and hence, across the mitochondrial outer membrane. In this review, we examine how Molecular Dynamics, Free Energy, and Brownian Dynamics simulations of the large β-barrel channel, VDAC, advanced our understanding. We will provide a short overview of non-conventional techniques and also discuss examples of how the modeling excursions into VDAC biophysics prospectively aid experimental efforts. PMID:26940625
Orthodontics: computer-aided diagnosis and treatment planning
NASA Astrophysics Data System (ADS)
Yi, Yaxing; Li, Zhongke; Wei, Suyuan; Deng, Fanglin; Yao, Sen
2000-10-01
The purpose of this article is to introduce the outline of our newly developed computer-aided 3D dental cast analyzing system with laser scanning, and its preliminary clinical applications. The system is composed of a scanning device and a personal computer as a scanning controller and post processor. The scanning device is composed of a laser beam emitter, two sets of linear CCD cameras and a table which is rotatable by two-degree-of-freedom. The rotating is controlled precisely by a personal computer. The dental cast is projected and scanned with a laser beam. Triangulation is applied to determine the location of each point. Generation of 3D graphics of the dental cast takes approximately 40 minutes. About 170,000 sets of X,Y,Z coordinates are store for one dental cast. Besides the conventional linear and angular measurements of the dental cast, we are also able to demonstrate the size of the top surface area of each molar. The advantage of this system is that it facilitates the otherwise complicated and time- consuming mock surgery necessary for treatment planning in orthognathic surgery.
Weak and Dynamic GNSS Signal Tracking Strategies for Flight Missions in the Space Service Volume
Jing, Shuai; Zhan, Xingqun; Liu, Baoyu; Chen, Maolin
2016-01-01
Weak-signal and high-dynamics are of two primary concerns of space navigation using GNSS (Global Navigation Satellite System) in the space service volume (SSV). The paper firstly defines a reference assumption third-order phase-locked loop (PLL) as the baseline of an onboard GNSS receiver, and proves the incompetence of this conventional architecture. Then an adaptive four-state Kalman filter (KF)-based algorithm is introduced to realize the optimization of loop noise bandwidth, which can adaptively regulate its filter gain according to the received signal power and line-of-sight (LOS) dynamics. To overcome the matter of losing lock in weak-signal and high-dynamic environments, an open loop tracking strategy aided by an inertial navigation system (INS) is recommended, and the traditional maximum likelihood estimation (MLE) method is modified in a non-coherent way by reconstructing the likelihood cost function. Furthermore, a typical mission with combined orbital maneuvering and non-maneuvering arcs is taken as a destination object to test the two proposed strategies. Finally, the experiment based on computer simulation identifies the effectiveness of an adaptive four-state KF-based strategy under non-maneuvering conditions and the virtue of INS-assisted methods under maneuvering conditions. PMID:27598164
Weak and Dynamic GNSS Signal Tracking Strategies for Flight Missions in the Space Service Volume.
Jing, Shuai; Zhan, Xingqun; Liu, Baoyu; Chen, Maolin
2016-09-02
Weak-signal and high-dynamics are of two primary concerns of space navigation using GNSS (Global Navigation Satellite System) in the space service volume (SSV). The paper firstly defines a reference assumption third-order phase-locked loop (PLL) as the baseline of an onboard GNSS receiver, and proves the incompetence of this conventional architecture. Then an adaptive four-state Kalman filter (KF)-based algorithm is introduced to realize the optimization of loop noise bandwidth, which can adaptively regulate its filter gain according to the received signal power and line-of-sight (LOS) dynamics. To overcome the matter of losing lock in weak-signal and high-dynamic environments, an open loop tracking strategy aided by an inertial navigation system (INS) is recommended, and the traditional maximum likelihood estimation (MLE) method is modified in a non-coherent way by reconstructing the likelihood cost function. Furthermore, a typical mission with combined orbital maneuvering and non-maneuvering arcs is taken as a destination object to test the two proposed strategies. Finally, the experiment based on computer simulation identifies the effectiveness of an adaptive four-state KF-based strategy under non-maneuvering conditions and the virtue of INS-assisted methods under maneuvering conditions.
Harnessing the Potential of Additive Manufacturing
2016-12-01
manufacturing age, which is dominated by standards for materials, processes and process control. Conventional manufacturing is based upon a design that is...documented either in a drawing or a computer-aided design (CAD) file. The manufacturing team then develops a docu- mented public or private process for...31 Defense AT&L: November-December 2016 Harnessing the Potential of Additive Manufacturing Bill Decker Decker is director of Technology
Chen, Xiaojun; Yuan, Jianbing; Wang, Chengtao; Huang, Yuanliang; Kang, Lu
2010-09-01
In the field of oral implantology, there is a trend toward computer-aided implant surgery, especially the application of computerized tomography (CT)-derived surgical templates. However, because of relatively unsatisfactory match between the templates and receptor sites, conventional surgical templates may not be accurate enough for the severely resorbed edentulous cases during the procedure of transferring the preoperative plan to the actual surgery. The purpose of this study is to introduce a novel bone-tooth-combined-supported surgical guide, which is designed by utilizing a special modular software and fabricated via stereolithography technique using both laser scanning and CT imaging, thus improving the fit accuracy and reliability. A modular preoperative planning software was developed for computer-aided oral implantology. With the introduction of dynamic link libraries and some well-known free, open-source software libraries such as Visualization Toolkit (Kitware, Inc., New York, USA) and Insight Toolkit (Kitware, Inc.) a plug-in evolutive software architecture was established, allowing for expandability, accessibility, and maintainability in our system. To provide a link between the preoperative plan and the actual surgery, a novel bone-tooth-combined-supported surgical template was fabricated, utilizing laser scanning, image registration, and rapid prototyping. Clinical studies were conducted on four partially edentulous cases to make a comparison with the conventional bone-supported templates. The fixation was more stable than tooth-supported templates because laser scanning technology obtained detailed dentition information, which brought about the unique topography between the match surface of the templates and the adjacent teeth. The average distance deviations at the coronal and apical point of the implant were 0.66 mm (range: 0.3-1.2) and 0.86 mm (range: 0.4-1.2), and the average angle deviation was 1.84 degrees (range: 0.6-2.8 degrees ). This pilot study proves that the novel combined-supported templates are superior to the conventional ones. However, more clinical cases will be conducted to demonstrate their feasibility and reliability.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-24
... regimes and is working on becoming a member of the regimes. Albania and Croatia are parties to the Nuclear Non-Proliferation Treaty, the Chemical Weapons Convention, and the Biological Weapons Convention. In...
The evolving role of new imaging methods in breast screening.
Houssami, Nehmat; Ciatto, Stefano
2011-09-01
The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.
Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru
2017-11-01
Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.
Peel, Sean; Bhatia, Satyajeet; Eggbeer, Dominic; Morris, Daniel S; Hayhurst, Caroline
2017-06-01
Previously published evidence has established major clinical benefits from using computer-aided design, computer-aided manufacturing, and additive manufacturing to produce patient-specific devices. These include cutting guides, drilling guides, positioning guides, and implants. However, custom devices produced using these methods are still not in routine use, particularly by the UK National Health Service. Oft-cited reasons for this slow uptake include the following: a higher up-front cost than conventionally fabricated devices, material-choice uncertainty, and a lack of long-term follow-up due to their relatively recent introduction. This article identifies a further gap in current knowledge - that of design rules, or key specification considerations for complex computer-aided design/computer-aided manufacturing/additive manufacturing devices. This research begins to address the gap by combining a detailed review of the literature with first-hand experience of interdisciplinary collaboration on five craniofacial patient case studies. In each patient case, bony lesions in the orbito-temporal region were segmented, excised, and reconstructed in the virtual environment. Three cases translated these digital plans into theatre via polymer surgical guides. Four cases utilised additive manufacturing to fabricate titanium implants. One implant was machined from polyether ether ketone. From the literature, articles with relevant abstracts were analysed to extract design considerations. In all, 19 frequently recurring design considerations were extracted from previous publications. Nine new design considerations were extracted from the case studies - on the basis of subjective clinical evaluation. These were synthesised to produce a design considerations framework to assist clinicians with prescribing and design engineers with modelling. Promising avenues for further research are proposed.
Dahl, Bjørn E; Dahl, Jon E; Rønold, Hans J
2018-02-01
Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 μm and 300 μm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 μm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique. © 2017 Eur J Oral Sci.
Maldonado, Fabien; Boland, Jennifer M.; Raghunath, Sushravya; Aubry, Marie Christine; Bartholmai, Brian J.; deAndrade, Mariza; Hartman, Thomas E.; Karwoski, Ronald A.; Rajagopalan, Srinivasan; Sykes, Anne-Marie; Yang, Ping; Yi, Eunhee S.; Robb, Richard A.; Peikert, Tobias
2013-01-01
Introduction Pulmonary nodules of the adenocarcinoma spectrum are characterized by distinctive morphological and radiological features and variable prognosis. Non-invasive high-resolution computed-tomography (HRCT)-based risk stratification tools are needed to individualize their management. Methods Radiological measurements of histopathologic tissue invasion were developed in a training set of 54 pulmonary nodules of the adenocarcinoma spectrum and validated in 86 consecutively resected nodules. Nodules were isolated and characterized by computer-aided analysis and data were analyzed by Spearman correlation, sensitivity, specificity as well as the positive and negative predictive values. Results Computer Aided Nodule Assessment and Risk Yield (CANARY) can non-invasively characterize pulmonary nodules of the adenocarcinoma spectrum. Unsupervised clustering analysis of HRCT data identified 9 unique exemplars representing the basic radiologic building blocks of these lesions. The exemplar distribution within each nodule correlated well with the proportion of histologic tissue invasion, Spearman R=0.87,p < 0.0001 and 0.89,p < 0.0001 for the training and the validation set, respectively. Clustering of the exemplars in three-dimensional space corresponding to tissue invasion and lepidic growth was used to develop a CANARY decision algorithm, which successfully categorized these pulmonary nodules as “aggressive” (invasive adenocarcinoma) or “indolent” (adenocarcinoma in situ and minimally invasive adenocarcinoma). Sensitivity, specificity, positive predictive value and negative predictive value of this approach for the detection of “aggressive” lesions were 95.4%, 96.8%, 95.4% and 96.8%, respectively in the training set and 98.7%, 63.6%, 94.9% and 87.5%, respectively in the validation set. Conclusion CANARY represents a promising tool to non-invasively risk stratify pulmonary nodules of the adenocarcinoma spectrum. PMID:23486265
The microcomputer in the dental office: a new diagnostic aid.
van der Stelt, P F
1985-06-01
The first computer applications in the dental office were based upon standard accountancy procedures. Recently, more and more computer applications have become available to meet the specific requirements of dental practice. This implies not only business procedures, but also facilities to store patient records in the system and retrieve them easily. Another development concerns the automatic calculation of diagnostic data such as those provided in cephalometric analysis. Furthermore, growth and surgical results in the craniofacial area can be predicted by computerized extrapolation. Computers have been useful in obtaining the patient's anamnestic data objectively and for the making of decisions based on such data. Computer-aided instruction systems have been developed for undergraduate students to bridge the gap between textbook and patient interaction without the risks inherent in the latter. Radiology will undergo substantial changes as a result of the application of electronic imaging devices instead of the conventional radiographic films. Computer-assisted electronic imaging will enable image processing, image enhancement, pattern recognition and data transmission for consultation and storage purposes. Image processing techniques will increase image quality whilst still allowing low-dose systems. Standardization of software and system configuration and the development of 'user friendly' programs is the major concern for the near future.
Taylor, A L; Alfven, T; Hougendobler, D; Tanaka, S; Buse, K
2014-02-01
As countries contend with an increasingly complex global environment with direct implications for population health, the international community is seeking novel mechanisms to incentivize coordinated national and international action towards shared health goals. Binding legal instruments have garnered increasing attention since the World Health Organization adopted its first convention in 2003. This paper seeks to expand the discourse on future global health lawmaking by exploring the potential value of non-binding instruments in global health governance, drawing on the case of the 2001 United Nations General Assembly Special Session Declaration of Commitment on HIV/AIDS. In other realms of international concern ranging from the environment to human rights to arms control, non-binding instruments are increasingly used as effective instruments of international cooperation. The experience of the Global AIDS Reporting Mechanism, established pursuant to the Declaration, evidences that, at times, non-binding legal instruments can offer benefits over slower, more rigid binding legal approaches to governance. The global AIDS response has demonstrated that the use of a non-binding instrument can be remarkably effective in galvanizing increasingly deep commitments, action, reporting compliance and ultimately accountability for results. Based on this case, the authors argued that non-binding instruments deserve serious consideration by the international community for the future of global health governance, including in the context of WHO reform. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Maidment, David W; Barker, Alex B; Xia, Jun; Ferguson, Melanie A
2016-10-27
Hearing loss is a major public health concern, affecting over 11 million people in the UK. While hearing aids are the most common clinical intervention for hearing loss, the majority of people that would benefit from using hearing aids do not take them up. Recent technological advances have led to a rapid increase of alternative listening devices to conventional hearing aids. These include hearing aids that can be customised using a smartphone, smartphone-based 'hearing aid' apps, personal sound amplification products and wireless hearing products. However, no systematic review has been published evaluating whether alternative listening devices are an effective management strategy for people with hearing loss. The objective of this systematic review is to assess whether alternative listening devices are an effective intervention for adults with hearing loss. Methods are reported according to the Preferred Reporting Items for Systematic reviews and Meta-analyses Protocols (PRISMA-P) 2015 checklist. Retrospective or prospective studies, randomised controlled trials, non-randomised controlled trials, and before-after comparison studies will be eligible for inclusion. We will include studies with adult participants (≥18 years) with a mild or moderate hearing loss. The intervention should be an alternative listening device to a conventional hearing aid (comparison). Studies will be restricted to outcomes associated with the consequences of hearing loss. We will search relevant databases to identify published, completed but unpublished and ongoing trials. The overall quality of included evidence will be evaluated using the GRADE system, and meta-analysis performed if appropriate. No ethical issues are foreseen. The findings will be reported at national and international conferences, primarily audiology, and ear, nose and throat, and in a peer-reviewed journal using the PRISMA guidelines. PROSPERO CRD4201502958. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
CAGI: Computer Aided Grid Interface. A work in progress
NASA Technical Reports Server (NTRS)
Soni, Bharat K.; Yu, Tzu-Yi; Vaughn, David
1992-01-01
Progress realized in the development of a Computer Aided Grid Interface (CAGI) software system in integrating CAD/CAM geometric system output and/or Interactive Graphics Exchange Standard (IGES) files, geometry manipulations associated with grid generation, and robust grid generation methodologies is presented. CAGI is being developed in a modular fashion and will offer fast, efficient and economical response to geometry/grid preparation, allowing the ability to upgrade basic geometry in a step-by-step fashion interactively and under permanent visual control along with minimizing the differences between the actual hardware surface descriptions and corresponding numerical analog. The computer code GENIE is used as a basis. The Non-Uniform Rational B-Splines (NURBS) representation of sculptured surfaces is utilized for surface grid redistribution. The computer aided analysis system, PATRAN, is adapted as a CAD/CAM system. The progress realized in NURBS surface grid generation, the development of IGES transformer, and geometry adaption using PATRAN will be presented along with their applicability to grid generation associated with rocket propulsion applications.
Kumar, Rahul; Patil, Suvarna
2012-01-01
The aim of this study is to present a report of a case where forced orthodontic extrusion and computer-aided design and computer-aided manufacturing (CAD/CAM) technique was used for reconstruction of right maxillary central incisor with grossly destructed crown. Aesthetic rehabilitation of a fractured maxillary right central incisor was performed employing a multidisciplinary approach i.e. conventional endodontic treatment followed by orthodontic extrusion and final restoration using CAD-CAM and one piece milled zirconia post and core with full coverage zirconia crown. After the procedure being completed, periapical radiographs taken at 3 month follow up period demonstrated that the post and core remained well adapted to post space and there was a complete healing of periapical lesion. This technique can provide a complete aesthetic rehabilitation of a grossly destructed tooth without hampering the biological width and thus has a better prognosis. PMID:22557823
From Phonomecanocardiography to Phonocardiography computer aided
NASA Astrophysics Data System (ADS)
Granados, J.; Tavera, F.; López, G.; Velázquez, J. M.; Hernández, R. T.; López, G. A.
2017-01-01
Due to lack of training doctors to identify many of the disorders in the heart by conventional listening, it is necessary to add an objective and methodological analysis to support this technique. In order to obtain information of the performance of the heart to be able to diagnose heart disease through a simple, cost-effective procedure by means of a data acquisition system, we have obtained Phonocardiograms (PCG), which are images of the sounds emitted by the heart. A program of acoustic, visual and artificial vision recognition was elaborated to interpret them. Based on the results of previous research of cardiologists a code of interpretation of PCG and associated diseases was elaborated. Also a site, within the university campus, of experimental sampling of cardiac data was created. Phonocardiography computer-aided is a viable and low cost procedure which provides additional medical information to make a diagnosis of complex heart diseases. We show some previous results.
Afify, Ahmed; Haney, Stephan
2016-08-01
Since it was first introduced into the dental world, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has improved dramatically in regards to both data acquisition and fabrication abilities. CAD/CAM is capable of providing well-fitting intra- and extraoral prostheses when sound guidelines are followed. As CAD/CAM technology encompasses both surgical and prosthetic dental applications as well as fixed and removable aspects, it could improve the average quality of dental prostheses compared with the results obtained by conventional manufacturing methods. The purpose of this article is to provide an introduction into the methods in which this technology may be used to enhance the wear and fracture resistance of dentures and overdentures. This article will also showcase two clinical reports in which CAD/CAM technology has been implemented. © 2016 by the American College of Prosthodontists.
An integrated computational tool for precipitation simulation
NASA Astrophysics Data System (ADS)
Cao, W.; Zhang, F.; Chen, S.-L.; Zhang, C.; Chang, Y. A.
2011-07-01
Computer aided materials design is of increasing interest because the conventional approach solely relying on experimentation is no longer viable within the constraint of available resources. Modeling of microstructure and mechanical properties during precipitation plays a critical role in understanding the behavior of materials and thus accelerating the development of materials. Nevertheless, an integrated computational tool coupling reliable thermodynamic calculation, kinetic simulation, and property prediction of multi-component systems for industrial applications is rarely available. In this regard, we are developing a software package, PanPrecipitation, under the framework of integrated computational materials engineering to simulate precipitation kinetics. It is seamlessly integrated with the thermodynamic calculation engine, PanEngine, to obtain accurate thermodynamic properties and atomic mobility data necessary for precipitation simulation.
Non-Traditional Methods of Improving the Communication Skills of Disadvantaged Students
ERIC Educational Resources Information Center
Wilson, Brenda M.; Power, Marian E.
1978-01-01
Educators are encouraged to use some of the non-traditional student-centered methods for improving the communication skills of disadvantaged students, including technological aids such as books, tapes, cable T.V., video tapes, computers, etc., and devices such as role playing and dramatizations. (AM)
Bone tissue engineering scaffolding: computer-aided scaffolding techniques.
Thavornyutikarn, Boonlom; Chantarapanich, Nattapon; Sitthiseripratip, Kriskrai; Thouas, George A; Chen, Qizhi
Tissue engineering is essentially a technique for imitating nature. Natural tissues consist of three components: cells, signalling systems (e.g. growth factors) and extracellular matrix (ECM). The ECM forms a scaffold for its cells. Hence, the engineered tissue construct is an artificial scaffold populated with living cells and signalling molecules. A huge effort has been invested in bone tissue engineering, in which a highly porous scaffold plays a critical role in guiding bone and vascular tissue growth and regeneration in three dimensions. In the last two decades, numerous scaffolding techniques have been developed to fabricate highly interconnective, porous scaffolds for bone tissue engineering applications. This review provides an update on the progress of foaming technology of biomaterials, with a special attention being focused on computer-aided manufacturing (Andrade et al. 2002) techniques. This article starts with a brief introduction of tissue engineering (Bone tissue engineering and scaffolds) and scaffolding materials (Biomaterials used in bone tissue engineering). After a brief reviews on conventional scaffolding techniques (Conventional scaffolding techniques), a number of CAM techniques are reviewed in great detail. For each technique, the structure and mechanical integrity of fabricated scaffolds are discussed in detail. Finally, the advantaged and disadvantage of these techniques are compared (Comparison of scaffolding techniques) and summarised (Summary).
Computer-aided Classification of Mammographic Masses Using Visually Sensitive Image Features
Wang, Yunzhi; Aghaei, Faranak; Zarafshani, Ali; Qiu, Yuchen; Qian, Wei; Zheng, Bin
2017-01-01
Purpose To develop a new computer-aided diagnosis (CAD) scheme that computes visually sensitive image features routinely used by radiologists to develop a machine learning classifier and distinguish between the malignant and benign breast masses detected from digital mammograms. Methods An image dataset including 301 breast masses was retrospectively selected. From each segmented mass region, we computed image features that mimic five categories of visually sensitive features routinely used by radiologists in reading mammograms. We then selected five optimal features in the five feature categories and applied logistic regression models for classification. A new CAD interface was also designed to show lesion segmentation, computed feature values and classification score. Results Areas under ROC curves (AUC) were 0.786±0.026 and 0.758±0.027 when to classify mass regions depicting on two view images, respectively. By fusing classification scores computed from two regions, AUC increased to 0.806±0.025. Conclusion This study demonstrated a new approach to develop CAD scheme based on 5 visually sensitive image features. Combining with a “visual aid” interface, CAD results may be much more easily explainable to the observers and increase their confidence to consider CAD generated classification results than using other conventional CAD approaches, which involve many complicated and visually insensitive texture features. PMID:27911353
Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.
Alp, Gülce; Murat, Sema; Yilmaz, Burak
2018-01-28
To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p < 0.05). CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p < 0.05), and conventional PMMA (p < 0.0001), and significantly lower flexural strength compared to CAD/CAM PMMA-based M (p < 0.05). The flexural strength of CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.
de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As
The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.
The use of a computerized algorithm to determine single cardiac cell volumes.
Marino, T A; Cook, L; Cook, P N; Dwyer, S J
1981-04-01
Single cardiac muscles cell volume data have been difficult to obtain, especially because the shape of a cell is quite complex. With the aid of a surface reconstruction method, a cell volume estimation algorithm has been developed that can be used on serial of cells. The cell surface is reconstructed by means of triangular tiles so that the cell is represented as a polyhedron. When this algorithm was tested on computer generated surfaces of a known volume, the difference was less than 1.6%. Serial sections of two phantoms of a known volume were also reconstructed and a comparison of the mathematically derived volumes and the computed volume estimations gave a per cent difference of between 2.8% and 4.1%. Finally cell volumes derived using conventional methods and volumes calculated using the algorithm were compared. The mean atrial muscle cell volume derived using conventional methods was 7752.7 +/- 644.7 micrometers3, while the mean computerized algorithm estimated atrial muscle cell volume was 7110.6 +/- 625.5 micrometers3. For AV bundle cells the mean cell volume obtained by conventional methods was 484.4 +/- 88.8 micrometers3 and the volume derived from the computer algorithm was 506.0 +/- 78.5 micrometers3. The differences between the volumes calculated using conventional methods and the algorithm were not significantly different.
Addition of flexible body option to the TOLA computer program, part 1
NASA Technical Reports Server (NTRS)
Dick, J. W.; Benda, B. J.
1975-01-01
This report describes a flexible body option that was developed and added to the Takeoff and Landing Analysis (TOLA) computer program. The addition of the flexible body option to TOLA allows it to be used to study essentially any conventional type airplane in the ground operating environment. It provides the capability to predict the total motion of selected points on the analytical methods incorporated in the program and operating instructions for the option are described. A program listing is included along with several example problems to aid in interpretation of the operating instructions and to illustrate program usage.
LLNL Partners with IBM on Brain-Like Computing Chip
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Essen, Brian
Lawrence Livermore National Laboratory (LLNL) will receive a first-of-a-kind brain-inspired supercomputing platform for deep learning developed by IBM Research. Based on a breakthrough neurosynaptic computer chip called IBM TrueNorth, the scalable platform will process the equivalent of 16 million neurons and 4 billion synapses and consume the energy equivalent of a hearing aid battery – a mere 2.5 watts of power. The brain-like, neural network design of the IBM Neuromorphic System is able to infer complex cognitive tasks such as pattern recognition and integrated sensory processing far more efficiently than conventional chips.
LLNL Partners with IBM on Brain-Like Computing Chip
Van Essen, Brian
2018-06-25
Lawrence Livermore National Laboratory (LLNL) will receive a first-of-a-kind brain-inspired supercomputing platform for deep learning developed by IBM Research. Based on a breakthrough neurosynaptic computer chip called IBM TrueNorth, the scalable platform will process the equivalent of 16 million neurons and 4 billion synapses and consume the energy equivalent of a hearing aid battery â a mere 2.5 watts of power. The brain-like, neural network design of the IBM Neuromorphic System is able to infer complex cognitive tasks such as pattern recognition and integrated sensory processing far more efficiently than conventional chips.
Recent development on computer aided tissue engineering--a review.
Sun, Wei; Lal, Pallavi
2002-02-01
The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineering, particularly, in computer-aided tissue anatomical modeling, three-dimensional (3-D) anatomy visualization and 3-D reconstruction, CAD-based anatomical modeling, computer-aided tissue classification, computer-aided tissue implantation and prototype modeling assisted surgical planning and reconstruction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalashnikova, Irina
2012-05-01
A numerical study aimed to evaluate different preconditioners within the Trilinos Ifpack and ML packages for the Quantum Computer Aided Design (QCAD) non-linear Poisson problem implemented within the Albany code base and posed on the Ottawa Flat 270 design geometry is performed. This study led to some new development of Albany that allows the user to select an ML preconditioner with Zoltan repartitioning based on nodal coordinates, which is summarized. Convergence of the numerical solutions computed within the QCAD computational suite with successive mesh refinement is examined in two metrics, the mean value of the solution (an L{sup 1} norm)more » and the field integral of the solution (L{sup 2} norm).« less
Aviation Careers Series: Airline Non-Flying Careers
DOT National Transportation Integrated Search
1996-01-01
TRAVLINK demonstrated the use of Automatic Vehicle Location (AVL), ComputerAided dispatch (CAD), and Automatic Vehicle Identification (AVI) systems on Metropolitan Council Transit Operations (MCTO) buses in Minneapolis, Minnesota and western suburbs,...
Krug, Klaus-Peter; Knauber, Andreas W; Nothdurft, Frank P
2015-03-01
The aim of this study was to investigate the fracture behavior of metal-ceramic bridges with frameworks from cobalt-chromium-molybdenum (CoCrMo), which are manufactured using conventional casting or a new computer-aided design/computer-aided manufacturing (CAD/CAM) milling and sintering technique. A total of 32 metal-ceramic fixed dental prostheses (FDPs), which are based on a nonprecious metal framework, was produced using a conventional casting process (n = 16) or a new CAD/CAM milling and sintering process (n = 16). Eight unveneered frameworks were manufactured using each of the techniques. After thermal and mechanical aging of half of the restorations, all samples were subjected to a static loading test in a universal testing machine, in which acoustic emission monitoring was performed. Three different critical forces were revealed: the fracture force (F max), the force at the first reduction in force (F decr1), and the force at the critical acoustic event (F acoust1). With the exception of the veneered restorations with cast or sintered metal frameworks without artificial aging, which presented a statistically significant but slightly different F max, no statistically significant differences between cast and CAD/CAM sintered and milled FDPs were detected. Thermal and mechanical loading did not significantly affect the resulting forces. Cast and CAD/CAM milled and sintered metal-ceramic bridges were determined to be comparable with respect to the fracture behavior. FDPs based on CAD/CAM milled and sintered frameworks may be an applicable and less technique-sensitive alternative to frameworks that are based on conventionally cast frameworks.
Barker, Alex B; Xia, Jun
2016-01-01
Introduction Hearing loss is a major public health concern, affecting over 11 million people in the UK. While hearing aids are the most common clinical intervention for hearing loss, the majority of people that would benefit from using hearing aids do not take them up. Recent technological advances have led to a rapid increase of alternative listening devices to conventional hearing aids. These include hearing aids that can be customised using a smartphone, smartphone-based ‘hearing aid’ apps, personal sound amplification products and wireless hearing products. However, no systematic review has been published evaluating whether alternative listening devices are an effective management strategy for people with hearing loss. Methods and analysis The objective of this systematic review is to assess whether alternative listening devices are an effective intervention for adults with hearing loss. Methods are reported according to the Preferred Reporting Items for Systematic reviews and Meta-analyses Protocols (PRISMA-P) 2015 checklist. Retrospective or prospective studies, randomised controlled trials, non-randomised controlled trials, and before-after comparison studies will be eligible for inclusion. We will include studies with adult participants (≥18 years) with a mild or moderate hearing loss. The intervention should be an alternative listening device to a conventional hearing aid (comparison). Studies will be restricted to outcomes associated with the consequences of hearing loss. We will search relevant databases to identify published, completed but unpublished and ongoing trials. The overall quality of included evidence will be evaluated using the GRADE system, and meta-analysis performed if appropriate. Ethics and dissemination No ethical issues are foreseen. The findings will be reported at national and international conferences, primarily audiology, and ear, nose and throat, and in a peer-reviewed journal using the PRISMA guidelines. Review registration number PROSPERO CRD4201502958. PMID:27789514
Measurement of breast volume using body scan technology(computer-aided anthropometry).
Veitch, Daisy; Burford, Karen; Dench, Phil; Dean, Nicola; Griffin, Philip
2012-01-01
Assessment of breast volume is an important tool for preoperative planning in various breast surgeries and other applications, such as bra development. Accurate assessment can improve the consistency and quality of surgery outcomes. This study outlines a non-invasive method to measure breast volume using a whole body 3D laser surface anatomy scanner, the Cyberware WBX. It expands on a previous publication where this method was validated against patients undergoing mastectomy. It specifically outlines and expands the computer-aided anthropometric (CAA) method for extracting breast volumes in a non-invasive way from patients enrolled in a breast reduction study at Flinders Medical Centre, South Australia. This step-by-step description allows others to replicate this work and provides an additional tool to assist them in their own clinical practice and development of designs.
Homsy, Foudda R; Özcan, Mutlu; Khoury, Marwan; Majzoub, Zeina A K
2018-05-01
The subtractive and additive computer-aided design and computer-aided manufacturing (CAD-CAM) of lithium disilicate partial coverage restorations is poorly documented. The purpose of this in vitro study was to compare the marginal and internal fit accuracy of lithium disilicate glass-ceramic inlays fabricated with conventional, milled, and 3-dimensional (3D) printed wax patterns. A dentoform mandibular first molar was prepared for a mesio-occlusal ceramic inlay. Five groups of 15 inlays were obtained through conventional impression and manual wax pattern (group CICW); conventional impression, laboratory scanning of the stone die, CAD-CAM milled wax blanks (group CIDW) or 3D printed wax patterns (group CI3DW); and scanning of the master preparation with intraoral scanner and CAD-CAM milled (group DSDW) or 3D printed wax patterns (group DS3DW). The same design was used to produce the wax patterns in the last 4 groups. The replica technique was used to measure marginal and internal adaptation by using stereomicroscopy. Mixed-model ANOVA was used to assess differences according to the groups and discrepancy location (α=.05). Group DSDW showed the smallest marginal discrepancy (24.3 μm) compared with those of groups CICW (45.1 μm), CIDW (33.7 μm), CI3DW (39.8 μm), and DS3DW (39.7 μm) (P<.001). No statistically significant differences were detected among groups CICW, CIDW, CI3DW, and DS3DW relative to the marginal discrepancy. The internal discrepancy was significantly larger than the marginal discrepancy within all groups (P<.001). Lithium disilicate glass-ceramic inlays produced from digital scans and subtractive milling of wax patterns resulted in better marginal and internal fit accuracy than either conventional impression/fabrication or additive 3D manufacturing. Three-dimensional printed wax patterns yielded fit values similar to those of the conventionally waxed inlays. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Computer network defense through radial wave functions
NASA Astrophysics Data System (ADS)
Malloy, Ian J.
The purpose of this research is to synthesize basic and fundamental findings in quantum computing, as applied to the attack and defense of conventional computer networks. The concept focuses on uses of radio waves as a shield for, and attack against traditional computers. A logic bomb is analogous to a landmine in a computer network, and if one was to implement it as non-trivial mitigation, it will aid computer network defense. As has been seen in kinetic warfare, the use of landmines has been devastating to geopolitical regions in that they are severely difficult for a civilian to avoid triggering given the unknown position of a landmine. Thus, the importance of understanding a logic bomb is relevant and has corollaries to quantum mechanics as well. The research synthesizes quantum logic phase shifts in certain respects using the Dynamic Data Exchange protocol in software written for this work, as well as a C-NOT gate applied to a virtual quantum circuit environment by implementing a Quantum Fourier Transform. The research focus applies the principles of coherence and entanglement from quantum physics, the concept of expert systems in artificial intelligence, principles of prime number based cryptography with trapdoor functions, and modeling radio wave propagation against an event from unknown parameters. This comes as a program relying on the artificial intelligence concept of an expert system in conjunction with trigger events for a trapdoor function relying on infinite recursion, as well as system mechanics for elliptic curve cryptography along orbital angular momenta. Here trapdoor both denotes the form of cipher, as well as the implied relationship to logic bombs.
Access to Inter-Organization Computer Networks.
1985-08-01
management of computing and information systems, system management . 20. ABSTRACT (Continue on reverse aide it neceeery end identify by block number) When two...necessary control mechanisms. Message-based gateways that support non-real-time invocation of services (e.g., file and print servers, financial ...operations (C.2.3), electronic mail (H.4.3), public policy issues (K.4.1), organizationa impacts (K.4.3), management of computing and information systems (K.6
Dung, Van Than; Tjahjowidodo, Tegoeh
2017-01-01
B-spline functions are widely used in many industrial applications such as computer graphic representations, computer aided design, computer aided manufacturing, computer numerical control, etc. Recently, there exist some demands, e.g. in reverse engineering (RE) area, to employ B-spline curves for non-trivial cases that include curves with discontinuous points, cusps or turning points from the sampled data. The most challenging task in these cases is in the identification of the number of knots and their respective locations in non-uniform space in the most efficient computational cost. This paper presents a new strategy for fitting any forms of curve by B-spline functions via local algorithm. A new two-step method for fast knot calculation is proposed. In the first step, the data is split using a bisecting method with predetermined allowable error to obtain coarse knots. Secondly, the knots are optimized, for both locations and continuity levels, by employing a non-linear least squares technique. The B-spline function is, therefore, obtained by solving the ordinary least squares problem. The performance of the proposed method is validated by using various numerical experimental data, with and without simulated noise, which were generated by a B-spline function and deterministic parametric functions. This paper also discusses the benchmarking of the proposed method to the existing methods in literature. The proposed method is shown to be able to reconstruct B-spline functions from sampled data within acceptable tolerance. It is also shown that, the proposed method can be applied for fitting any types of curves ranging from smooth ones to discontinuous ones. In addition, the method does not require excessive computational cost, which allows it to be used in automatic reverse engineering applications.
NASA Astrophysics Data System (ADS)
Freniere, Cole; Pathak, Ashish; Raessi, Mehdi
2016-11-01
Ocean Wave Energy Converters (WECs) are devices that convert energy from ocean waves into electricity. To aid in the design of WECs, an advanced computational framework has been developed which has advantages over conventional methods. The computational framework simulates the performance of WECs in a virtual wave tank by solving the full Navier-Stokes equations in 3D, capturing the fluid-structure interaction, nonlinear and viscous effects. In this work, we present simulations of the performance of pitching cylinder-type WECs and compare against experimental data. WECs are simulated at both model and full scales. The results are used to determine the role of the Keulegan-Carpenter (KC) number. The KC number is representative of viscous drag behavior on a bluff body in an oscillating flow, and is considered an important indicator of the dynamics of a WEC. Studying the effects of the KC number is important for determining the validity of the Froude scaling and the inviscid potential flow theory, which are heavily relied on in the conventional approaches to modeling WECs. Support from the National Science Foundation is gratefully acknowledged.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.
Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-03-08
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022
Mechanical and Thermal Properties of Dental Composites Cured with CAD/CAM Assisted Solid-State Laser
De Santis, Roberto; Gloria, Antonio; Maietta, Saverio; Martorelli, Massimo; De Luca, Alessandro; Spagnuolo, Gianrico; Riccitiello, Francesco; Rengo, Sandro
2018-01-01
Over the last three decades, it has been frequently reported that the properties of dental restorative composites cured with argon laser are similar or superior to those achieved with conventional halogen and light emitting diode (LED) curing units. Whereas laser curing is not dependent on the distance between the curing unit and the material, such distance represents a drawback for conventional curing units. However, a widespread clinical application of this kind of laser remains difficult due to cost, heavy weight, and bulky size. Recently, with regard to the radiation in the blue region of the spectrum, powerful solid-state lasers have been commercialized. In the current research, CAD (computer-aided design)/CAM (computer-aided manufacturing) assisted solid-state lasers were employed for curing of different dental restorative composites consisting of micro- and nanoparticle-reinforced materials based on acrylic resins. Commercial LED curing units were used as a control. Temperature rise during the photopolymerisation process and bending properties were measured. By providing similar light energy dose, no significant difference in temperature rise was observed when the two light sources provided similar intensity. In addition, after 7 days since curing, bending properties of composites cured with laser and LED were similar. The results suggested that this kind of laser would be suitable for curing dental composites, and the curing process does not suffer from the tip-to-tooth distance. PMID:29584683
Lessons learned from the design of chemical space networks and opportunities for new applications.
Vogt, Martin; Stumpfe, Dagmar; Maggiora, Gerald M; Bajorath, Jürgen
2016-03-01
The concept of chemical space is of fundamental relevance in chemical informatics and computer-aided drug discovery. In a series of articles published in the Journal of Computer-Aided Molecular Design, principles of chemical space design were evaluated, molecular networks proposed as an alternative to conventional coordinate-based chemical reference spaces, and different types of chemical space networks (CSNs) constructed and analyzed. Central to the generation of CSNs was the way in which molecular similarity relationships were assessed and a primary focal point was the network-based representation of biologically relevant chemical space. The design and comparison of CSNs based upon alternative similarity measures can be viewed as an evolutionary path with interesting lessons learned along the way. CSN design has matured to the point that such chemical space representations can be used in practice. In this contribution, highlights from the sequence of CSN design efforts are discussed in context, providing a perspective for future practical applications.
Lessons learned from the design of chemical space networks and opportunities for new applications
NASA Astrophysics Data System (ADS)
Vogt, Martin; Stumpfe, Dagmar; Maggiora, Gerald M.; Bajorath, Jürgen
2016-03-01
The concept of chemical space is of fundamental relevance in chemical informatics and computer-aided drug discovery. In a series of articles published in the Journal of Computer- Aided Molecular Design, principles of chemical space design were evaluated, molecular networks proposed as an alternative to conventional coordinate-based chemical reference spaces, and different types of chemical space networks (CSNs) constructed and analyzed. Central to the generation of CSNs was the way in which molecular similarity relationships were assessed and a primary focal point was the network-based representation of biologically relevant chemical space. The design and comparison of CSNs based upon alternative similarity measures can be viewed as an evolutionary path with interesting lessons learned along the way. CSN design has matured to the point that such chemical space representations can be used in practice. In this contribution, highlights from the sequence of CSN design efforts are discussed in context, providing a perspective for future practical applications.
An evaluation of computer-aided disproportionality analysis for post-marketing signal detection.
Lehman, H P; Chen, J; Gould, A L; Kassekert, R; Beninger, P R; Carney, R; Goldberg, M; Goss, M A; Kidos, K; Sharrar, R G; Shields, K; Sweet, A; Wiholm, B E; Honig, P K
2007-08-01
To understand the value of computer-aided disproportionality analysis (DA) in relation to current pharmacovigilance signal detection methods, four products were retrospectively evaluated by applying an empirical Bayes method to Merck's post-marketing safety database. Findings were compared with the prior detection of labeled post-marketing adverse events. Disproportionality ratios (empirical Bayes geometric mean lower 95% bounds for the posterior distribution (EBGM05)) were generated for product-event pairs. Overall (1993-2004 data, EBGM05> or =2, individual terms) results of signal detection using DA compared to standard methods were sensitivity, 31.1%; specificity, 95.3%; and positive predictive value, 19.9%. Using groupings of synonymous labeled terms, sensitivity improved (40.9%). More of the adverse events detected by both methods were detected earlier using DA and grouped (versus individual) terms. With 1939-2004 data, diagnostic properties were similar to those from 1993 to 2004. DA methods using Merck's safety database demonstrate sufficient sensitivity and specificity to be considered for use as an adjunct to conventional signal detection methods.
Custom hip prostheses by integrating CAD and casting technology
NASA Astrophysics Data System (ADS)
Silva, Pedro F.; Leal, Nuno; Neto, Rui J.; Lino, F. Jorge; Reis, Ana
2012-09-01
Total Hip Arthroplasty (THA) is a surgical intervention that is being achieving high rates of success, leaving room to research on long run durability, patient comfort and costs reduction. Even so, up to the present, little research has been done to improve the method of manufacturing customized prosthesis. The common customized prostheses are made by full machining. This document presents a different approach methodology which combines the study of medical images, through CAD (Computer Aided Design) software, SLadditive manufacturing, ceramic shell manufacture, precision foundry with Titanium alloys and Computer Aided Manufacturing (CAM). The goal is to achieve the best comfort for the patient, stress distribution and the maximum lifetime of the prosthesis produced by this integrated methodology. The way to achieve this desiderate is to make custom hip prosthesis which are adapted to each patient needs and natural physiognomy. Not only the process is reliable, but also represents a cost reduction comparing to the conventional full machined custom hip prosthesis.
Aeroelastic Deflection of NURBS Geometry
NASA Technical Reports Server (NTRS)
Samareh, Jamshid A.
1998-01-01
The purpose of this paper is to present an algorithm for using NonUniform Rational B-Spline (NURBS) representation in an aeroelastic loop. The algorithm is based on creating a least-squares NURBS surface representing the aeroelastic defection. The resulting NURBS surfaces are used to update either the original Computer- Aided Design (CAD) model, Computational Structural Mechanics (CSM) grid or the Computational Fluid Dynamics (CFD) grid. Results are presented for a generic High-Speed Civil Transport (HSCT).
Sailer, Irena; Benic, Goran I; Fehmer, Vincent; Hämmerle, Christoph H F; Mühlemann, Sven
2017-07-01
Clinical studies are needed to evaluate the entire digital and conventional workflows in prosthetic dentistry. The purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported single crowns made with 4 different digital workflows and 1 conventional workflow and to compare these crowns clinically. For each of 10 participants, a monolithic crown was fabricated in lithium disilicate-reinforced glass ceramic (IPS e.max CAD). The computer-aided design and computer-aided manufacturing (CAD-CAM) systems were Lava C.O.S. CAD software and centralized CAM (group L), Cares CAD software and centralized CAM (group iT), Cerec Connect CAD software and lab side CAM (group CiL), and Cerec Connect CAD software with centralized CAM (group CiD). The conventional fabrication (group K) included a wax pattern of the crown and heat pressing according to the lost-wax technique (IPS e.max Press). The time for the fabrication of the casts and the crowns was recorded. Subsequently, the crowns were clinically evaluated and the corresponding treatment times were recorded. The Paired Wilcoxon test with the Bonferroni correction was applied to detect differences among treatment groups (α=.05). The total mean (±standard deviation) active working time for the dental technician was 88 ±6 minutes in group L, 74 ±12 minutes in group iT, 74 ±5 minutes in group CiL, 92 ±8 minutes in group CiD, and 148 ±11 minutes in group K. The dental technician spent significantly more working time for the conventional workflow than for the digital workflows (P<.001). No statistically significant differences were found between group L and group CiD or between group iT and group CiL. No statistical differences in time for the clinical evaluation were found among groups, indicating similar outcomes (P>.05). Irrespective of the CAD-CAM system, the overall laboratory working time for a digital workflow was significantly shorter than for the conventional workflow, since the dental technician needed less active working time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The Effect of Adaptive Nonlinear Frequency Compression on Phoneme Perception.
Glista, Danielle; Hawkins, Marianne; Bohnert, Andrea; Rehmann, Julia; Wolfe, Jace; Scollie, Susan
2017-12-12
This study implemented a fitting method, developed for use with frequency lowering hearing aids, across multiple testing sites, participants, and hearing aid conditions to evaluate speech perception with a novel type of frequency lowering. A total of 8 participants, including children and young adults, participated in real-world hearing aid trials. A blinded crossover design, including posttrial withdrawal testing, was used to assess aided phoneme perception. The hearing aid conditions included adaptive nonlinear frequency compression (NFC), static NFC, and conventional processing. Enabling either adaptive NFC or static NFC improved group-level detection and recognition results for some high-frequency phonemes, when compared with conventional processing. Mean results for the distinction component of the Phoneme Perception Test (Schmitt, Winkler, Boretzki, & Holube, 2016) were similar to those obtained with conventional processing. Findings suggest that both types of NFC tested in this study provided a similar amount of speech perception benefit, when compared with group-level performance with conventional hearing aid technology. Individual-level results are presented with discussion around patterns of results that differ from the group average.
NASA Astrophysics Data System (ADS)
Liang, Ruiyu; Xi, Ji; Bao, Yongqiang
2017-07-01
To improve the performance of gain compensation based on three-segment sound pressure level (SPL) in hearing aids, an improved multichannel loudness compensation method based on eight-segment SPL was proposed. Firstly, the uniform cosine modulated filter bank was designed. Then, the adjacent channels which have low or gradual slopes were adaptively merged to obtain the corresponding non-uniform cosine modulated filter according to the audiogram of hearing impaired persons. Secondly, the input speech was decomposed into sub-band signals and the SPL of every sub-band signal was computed. Meanwhile, the audible SPL range from 0 dB SPL to 120 dB SPL was equally divided into eight segments. Based on these segments, a different prescription formula was designed to compute more detailed gain to compensate according to the audiogram and the computed SPL. Finally, the enhanced signal was synthesized. Objective experiments showed the decomposed signals after cosine modulated filter bank have little distortion. Objective experiments showed that the hearing aids speech perception index (HASPI) and hearing aids speech quality index (HASQI) increased 0.083 and 0.082 on average, respectively. Subjective experiments showed the proposed algorithm can effectively improve the speech recognition of six hearing impaired persons.
Non-Contact Smartphone-Based Monitoring of Thermally Stressed Structures
Ozturk, Turgut; Mas, David; Rizzo, Piervincenzo
2018-01-01
The in-situ measurement of thermal stress in beams or continuous welded rails may prevent structural anomalies such as buckling. This study proposed a non-contact monitoring/inspection approach based on the use of a smartphone and a computer vision algorithm to estimate the vibrating characteristics of beams subjected to thermal stress. It is hypothesized that the vibration of a beam can be captured using a smartphone operating at frame rates higher than conventional 30 Hz, and the first few natural frequencies of the beam can be extracted using a computer vision algorithm. In this study, the first mode of vibration was considered and compared to the information obtained with a conventional accelerometer attached to the two structures investigated, namely a thin beam and a thick beam. The results show excellent agreement between the conventional contact method and the non-contact sensing approach proposed here. In the future, these findings may be used to develop a monitoring/inspection smartphone application to assess the axial stress of slender structures, to predict the neutral temperature of continuous welded rails, or to prevent thermal buckling. PMID:29670034
Non-Contact Smartphone-Based Monitoring of Thermally Stressed Structures.
Sefa Orak, Mehmet; Nasrollahi, Amir; Ozturk, Turgut; Mas, David; Ferrer, Belen; Rizzo, Piervincenzo
2018-04-18
The in-situ measurement of thermal stress in beams or continuous welded rails may prevent structural anomalies such as buckling. This study proposed a non-contact monitoring/inspection approach based on the use of a smartphone and a computer vision algorithm to estimate the vibrating characteristics of beams subjected to thermal stress. It is hypothesized that the vibration of a beam can be captured using a smartphone operating at frame rates higher than conventional 30 Hz, and the first few natural frequencies of the beam can be extracted using a computer vision algorithm. In this study, the first mode of vibration was considered and compared to the information obtained with a conventional accelerometer attached to the two structures investigated, namely a thin beam and a thick beam. The results show excellent agreement between the conventional contact method and the non-contact sensing approach proposed here. In the future, these findings may be used to develop a monitoring/inspection smartphone application to assess the axial stress of slender structures, to predict the neutral temperature of continuous welded rails, or to prevent thermal buckling.
Repairability of CAD/CAM high-density PMMA- and composite-based polymers.
Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna
2015-11-01
The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite. Repair of PMMA- and composite-based polymers can be achieved by surface pretreatment followed by application of an adhesive and a conventional methacrylate-based composite.
Leuwer, R.; Müller, J.
2005-01-01
Aim of this report is to explain the current concept of hearing restoration using hearing aids. At present the main issues of conventional hearing aids are the relative benefits of analogue versus digital devices and different strategies for the improvement of hearing in noise. Implantable hearing aids provide a better sound quality and less distortion. The lack of directional microphones is the major disadvantage of the partially implantable hearing aids commercially available. Two different clinical studies about fully implantable hearing aids have been started in 2004. One of the most-promising developments seems to be the electric-acoustic stimulation. PMID:22073051
A machine learning approach for classification of anatomical coverage in CT
NASA Astrophysics Data System (ADS)
Wang, Xiaoyong; Lo, Pechin; Ramakrishna, Bharath; Goldin, Johnathan; Brown, Matthew
2016-03-01
Automatic classification of anatomical coverage of medical images is critical for big data mining and as a pre-processing step to automatically trigger specific computer aided diagnosis systems. The traditional way to identify scans through DICOM headers has various limitations due to manual entry of series descriptions and non-standardized naming conventions. In this study, we present a machine learning approach where multiple binary classifiers were used to classify different anatomical coverages of CT scans. A one-vs-rest strategy was applied. For a given training set, a template scan was selected from the positive samples and all other scans were registered to it. Each registered scan was then evenly split into k × k × k non-overlapping blocks and for each block the mean intensity was computed. This resulted in a 1 × k3 feature vector for each scan. The feature vectors were then used to train a SVM based classifier. In this feasibility study, four classifiers were built to identify anatomic coverages of brain, chest, abdomen-pelvis, and chest-abdomen-pelvis CT scans. Each classifier was trained and tested using a set of 300 scans from different subjects, composed of 150 positive samples and 150 negative samples. Area under the ROC curve (AUC) of the testing set was measured to evaluate the performance in a two-fold cross validation setting. Our results showed good classification performance with an average AUC of 0.96.
Alqahtani, Fawaz
2017-01-01
The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. This is an in vitro interventional study. The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap.
Digital versus conventional techniques for pattern fabrication of implant-supported frameworks
Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour
2018-01-01
Objective: The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Materials and Methods: Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method (n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal–Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. Statistical Analysis Used: One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. Results: The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups (P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group (P < 0.001), while there was no significant difference between the two other groups (P = 0.54). CAD/CAM group required significantly more adjustments (P < 0.001). Conclusions: CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations. PMID:29657528
Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.
Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour
2018-01-01
The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method ( n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal-Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups ( P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group ( P < 0.001), while there was no significant difference between the two other groups ( P = 0.54). CAD/CAM group required significantly more adjustments ( P < 0.001). CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations.
Comparison of digital intraoral scanners by single-image capture system and full-color movie system.
Yamamoto, Meguru; Kataoka, Yu; Manabe, Atsufumi
2017-01-01
The use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) restoration is rapidly increasing. This study was performed to evaluate the marginal and internal cement thickness and the adhesive gap of internal cavities comprising CAD/CAM materials using two digital impression acquisition methods and micro-computed tomography. Images obtained by a single-image acquisition system (Bluecam Ver. 4.0) and a full-color video acquisition system (Omnicam Ver. 4.2) were divided into the BL and OM groups, respectively. Silicone impressions were prepared from an ISO-standard metal mold, and CEREC Stone BC and New Fuji Rock IMP were used to create working models (n=20) in the BL and OM groups (n=10 per group), respectively. Individual inlays were designed in a conventional manner using designated software, and all restorations were prepared using CEREC inLab MC XL. These were assembled with the corresponding working models used for measurement, and the level of fit was examined by three-dimensional analysis based on micro-computed tomography. Significant differences in the marginal and internal cement thickness and adhesive gap spacing were found between the OM and BL groups. The full-color movie capture system appears to be a more optimal restoration system than the single-image capture system.
Al-Dwairi, Ziad N; Tahboub, Kawkab Y; Baba, Nadim Z; Goodacre, Charles J
2018-06-13
The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37 ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m 2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m 2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05). As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties. © 2018 by the American College of Prosthodontists.
Pattern of cancer risk in persons with AIDS in Italy in the HAART era
Dal Maso, L; Polesel, J; Serraino, D; Lise, M; Piselli, P; Falcini, F; Russo, A; Intrieri, T; Vercelli, M; Zambon, P; Tagliabue, G; Zanetti, R; Federico, M; Limina, R M; Mangone, L; De Lisi, V; Stracci, F; Ferretti, S; Piffer, S; Budroni, M; Donato, A; Giacomin, A; Bellù, F; Fusco, M; Madeddu, A; Vitarelli, S; Tessandori, R; Tumino, R; Suligoi, B; Franceschi, S
2009-01-01
A record-linkage study was carried out between the Italian AIDS Registry and 24 Italian cancer registries to compare cancer excess among persons with HIV/AIDS (PWHA) before and after the introduction of highly active antiretroviral therapy (HAART) in 1996. Standardised incidence ratios (SIR) were computed in 21951 AIDS cases aged 16–69 years reported between 1986 and 2005. Of 101 669 person-years available, 45 026 were after 1996. SIR for Kaposi sarcoma (KS) and non-Hodgkin lymphoma greatly decreased in 1997–2004 compared with 1986–1996, but high SIRs for KS persisted in the increasingly large fraction of PWHA who had an interval of <1 year between first HIV-positive test and AIDS diagnosis. A significant excess of liver cancer (SIR=6.4) emerged in 1997–2004, whereas the SIRs for cancer of the cervix (41.5), anus (44.0), lung (4.1), brain (3.2), skin (non-melanoma, 1.8), Hodgkin lymphoma (20.7), myeloma (3.9), and non-AIDS-defining cancers (2.2) were similarly elevated in the two periods. The excess of some potentially preventable cancers in PWHA suggests that HAART use must be accompanied by cancer-prevention strategies, notably antismoking and cervical cancer screening programmes. Improvements in the timely identification of HIV-positive individuals are also a priority in Italy to avoid the adverse consequences of delayed HAART use. PMID:19223894
Farah, Ra'fat I; Al-Harethi, Naji
2016-10-01
The aim of this study was to compare in vitro the marginal microleakage of glass ionomer-based provisional cement with resin-based provisional cement and zinc oxide non-eugenol (ZONE) provisional cement in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated interim restorations. Fifteen intact human premolars were prepared in a standardized manner for complete coverage of crown restorations. Interim crowns for the prepared teeth were then fabricated using CAD/CAM, and the specimens were randomized into three groups of provisional cementing agents (n = 5 each): Glass ionomer-based provisional cement (GC Fuji TEMP LT™), bisphenol-A-glycidyldimethacrylate (Bis-GMA)/ triethylene glycol dimethacrylate (TEGDMA) resin-based cement (UltraTemp® REZ), and ZONE cement (TempBond NE). After 24 hours of storage in distilled water at 37°C, the specimens were thermocycled and then stored again for 24 hours in distilled water at room temperature. Next, the specimens were placed in freshly prepared 2% aqueous methylene blue dye for 24 hours and then embedded in autopolymerizing acrylic resin blocks and sectioned in buccolingual and mesiodistal directions to assess dye penetration using a stereomicroscope. The results were statistically analyzed using a nonparametric Kruskal-Wallis test. Dunn's post hoc test with a Bonferroni correction test was used to compute multiple pairwise comparisons that identified differences among groups; the level of significance was set at p < 0.05. All groups exhibited marginal microleakage; the Bis-GMA/TEGDMA resin-based provisional cement demonstrated the lowest microleakage scores, which were statistically different from those of the glass ionomer-based provisional cement and the ZONE cement. The provisional cementing agents exhibited different sealing abilities. The Bis-GMA/TEGDMA resin-based provisional cement exhibited the most effective favorable sealing properties against dye penetration compared with the glass ionomer-based provisional cement and conventional ZONE cement. Newly introduced glass ionomer-based provisional cement proved to be inferior to resin-based provisional cement as far as marginal microleakage is concerned.
NASA Astrophysics Data System (ADS)
Rahe, Manfred; Ristau, Detlev; Schmidt, Holger
1993-06-01
In this paper, data of single layers of YbF3, BaF2, YF3, and NaF and multilayer coatings produced by conventional thermal evaporation (boat, e-beam) and ion assisted deposition (IAD) are compared. Hydrogen concentration depth profiling was performed using nuclear reaction analysis based on the reaction 1H(15N, (alpha) (gamma) )12C. Absorption was measured with the aid of a laser calorimeter and a cw CO2 laser. A computer-controlled test facility with a TEA CO2 laser was used for determining the 1-on-1 damage thresholds of the coatings. The results point out that the absorption and damage behavior of coatings for the CO2 laser wavelength are related to the total amount of species containing hydrogen. Most of the IAD coatings exhibit a lower hydrogen contamination than conventional thin films.
A Non-Intrusive Algorithm for Sensitivity Analysis of Chaotic Flow Simulations
NASA Technical Reports Server (NTRS)
Blonigan, Patrick J.; Wang, Qiqi; Nielsen, Eric J.; Diskin, Boris
2017-01-01
We demonstrate a novel algorithm for computing the sensitivity of statistics in chaotic flow simulations to parameter perturbations. The algorithm is non-intrusive but requires exposing an interface. Based on the principle of shadowing in dynamical systems, this algorithm is designed to reduce the effect of the sampling error in computing sensitivity of statistics in chaotic simulations. We compare the effectiveness of this method to that of the conventional finite difference method.
Do pre-trained deep learning models improve computer-aided classification of digital mammograms?
NASA Astrophysics Data System (ADS)
Aboutalib, Sarah S.; Mohamed, Aly A.; Zuley, Margarita L.; Berg, Wendie A.; Luo, Yahong; Wu, Shandong
2018-02-01
Digital mammography screening is an important exam for the early detection of breast cancer and reduction in mortality. False positives leading to high recall rates, however, results in unnecessary negative consequences to patients and health care systems. In order to better aid radiologists, computer-aided tools can be utilized to improve distinction between image classifications and thus potentially reduce false recalls. The emergence of deep learning has shown promising results in the area of biomedical imaging data analysis. This study aimed to investigate deep learning and transfer learning methods that can improve digital mammography classification performance. In particular, we evaluated the effect of pre-training deep learning models with other imaging datasets in order to boost classification performance on a digital mammography dataset. Two types of datasets were used for pre-training: (1) a digitized film mammography dataset, and (2) a very large non-medical imaging dataset. By using either of these datasets to pre-train the network initially, and then fine-tuning with the digital mammography dataset, we found an increase in overall classification performance in comparison to a model without pre-training, with the very large non-medical dataset performing the best in improving the classification accuracy.
Gunia, Sven; Koch, Stefan; Hakenberg, Oliver W; May, Matthias; Kakies, Christoph; Erbersdobler, Andreas
2011-12-01
We evaluated HER2 expression profiles in 32 carcinoma in situ (CIS) and 31 non-CIS conditions (5 dysplasia and 26 reactive atypia) of the urinary bladder mucosa by applying breast cancer scoring rules. In situ hybridization was performed on tissue microarrays to assess HER2 gene amplification status. Our immunoprofiling data disclosed moderate to strong HER2 expression in CIS, including the basal layer of the urothelium, and absent to weak HER2 expression in non-CIS conditions. From the histologic differential diagnostic standpoint, immunostaining for HER2 protein represents a useful adjunct to aid in the delineation between CIS and non-CIS conditions of the bladder mucosa. Pathogenically, aberrant HER2 protein expression in CIS seems to be more commonly associated with polysomy than with gene amplification. From a therapeutic viewpoint, prospective clinical studies should investigate the potential benefit of HER2-targeted therapies in CIS, particularly in cases unresponsive to conventional therapeutic regimens.
Human-Centered Design of Human-Computer-Human Dialogs in Aerospace Systems
NASA Technical Reports Server (NTRS)
Mitchell, Christine M.
1998-01-01
A series of ongoing research programs at Georgia Tech established a need for a simulation support tool for aircraft computer-based aids. This led to the design and development of the Georgia Tech Electronic Flight Instrument Research Tool (GT-EFIRT). GT-EFIRT is a part-task flight simulator specifically designed to study aircraft display design and single pilot interaction. ne simulator, using commercially available graphics and Unix workstations, replicates to a high level of fidelity the Electronic Flight Instrument Systems (EFIS), Flight Management Computer (FMC) and Auto Flight Director System (AFDS) of the Boeing 757/767 aircraft. The simulator can be configured to present information using conventional looking B757n67 displays or next generation Primary Flight Displays (PFD) such as found on the Beech Starship and MD-11.
Sharma, Meenu; Sharma, Vijay; Pathak, Kamla
2015-01-01
Cancer in individuals suffering with HIV and AIDS has become a common source of morbidity and mortality, especially in the underdeveloped world in which Kaposi's sarcoma is the most occurring tumor of vascular endothelium frequently seen in patients suffering from AIDS. Suffering individuals are invariably co-infected with HIV and HHV-8 virus. The conventional modes for chemotherapies may be clinically useful in patients with Kaposi's sarcoma. Though advancements in treatment modalities of AIDS related Kaposi's sarcoma have been successfully achieved, till date an exclusive therapy of golden standard has not been principally defined that can deliver the drug via non-invasive route. Novel concepts of treatment primarily address the factors that are associated with the pathogenesis of critical disease. On the other hand local therapies are aimed at eradicating primary lesions; and systemic chemotherapies are aimed to treat widespread visceral involvement. Increased understanding of the mechanisms underlying viral tumorigenesis will hopefully portray new therapeutic strategies. This review discusses novel drug delivery strategies that have been investigated for the effective and safe management of AIDS related kaposi's sarcoma. The review also highlights, the lipid based ultradeformable vesicular system that offers attractive drug delivery platform capable of delivering its payload without using invasive technique. These systems offer advance models for efficacious treatment of the future therapy aiming Kaposi's sarcoma.
Specht, Lena
2007-07-01
2-[18F]fluoro-2-deoxyglucose positron-emission tomography (FDG-PET) is used increasingly in the clinical management of lymphomas. With regard to staging, FDG-PET is more sensitive and specific than conventional staging methods in FDG avid lymphomas (ie, Hodgkin lymphoma and most aggressive non-Hodgkin lymphomas). Despite methodological problems, in particular the lack of a valid reference test, FDG-PET is approved and generally used for this purpose. With regard to response evaluation, FDG-PET at the end of treatment seems to aid considerably in differentiating between residual masses with or without residual lymphoma. Hence, new revised response criteria have been proposed, incorporating the result of FDG-PET at the end of treatment. An early interim FDG-PET scan after 1 to 3 cycles of chemotherapy is a very strong predictor of outcome, and trials are now in progress testing treatment modifications on this basis. With regard to treatment planning, in the context of combined-modality therapy, radiotherapy for lymphomas is moving toward more conformal techniques reducing the irradiated volume to include only the macroscopic lymphoma. In this situation, accurate imaging is essential, and FDG-PET coregistered with the planning computed tomography (CT) scan is used increasingly. The availability of PET/CT scanners suited for virtual simulation has aided this process. However, clinical data evaluating this technique are at present sparse.
The Technical Information Library: TIB
NASA Technical Reports Server (NTRS)
Rosemann, Uwe
1994-01-01
The Technische Informationsbibliothek Hannover (TIB) is the German national central library for all areas of technology and related sciences, especially chemistry, computer science, mathematics, and physics. The TIB acquires and makes available a comprehensive collection of conventional and non-conventional literature, especially foreign material, with particular emphasis on specialized new publications which are difficult to obtain or in difficult languages.
NASA Technical Reports Server (NTRS)
1989-01-01
C Language Integrated Production System (CLIPS) is a software shell for developing expert systems is designed to allow research and development of artificial intelligence on conventional computers. Originally developed by Johnson Space Center, it enables highly efficient pattern matching. A collection of conditions and actions to be taken if the conditions are met is built into a rule network. Additional pertinent facts are matched to the rule network. Using the program, E.I. DuPont de Nemours & Co. is monitoring chemical production machines; California Polytechnic State University is investigating artificial intelligence in computer aided design; Mentor Graphics has built a new Circuit Synthesis system, and Brooke and Brooke, a law firm, can determine which facts from a file are most important.
Computational fluid dynamics (CFD) study on the fetal aortic coarctation
NASA Astrophysics Data System (ADS)
Zhou, Yue; Zhang, Yutao; Wang, Jingying
2018-03-01
Blood flows in normal and coarctate fetal aortas are simulated by the CFD technique using T-rex grids. The three-dimensional (3-D) digital model of the fetal arota is reconstructed by the computer-aided design (CAD) software based on two-dimensional (2-D) ultrasono tomographic images. Simulation results displays the development and enhancement of the secondary flow structure in the coarctate fetal arota. As the diameter narrow ratio rises greater than 45%, the pressure and wall shear stress (WSS) of the aorta arch increase exponentially, which is consistent with the conventional clinical concept. The present study also demonstrates that CFD is a very promising assistant technique to investigate human cardiovascular diseases.
Segmentation of breast ultrasound images based on active contours using neutrosophic theory.
Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A
2018-04-01
Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.
Computer-based visual communication in aphasia.
Steele, R D; Weinrich, M; Wertz, R T; Kleczewska, M K; Carlson, G S
1989-01-01
The authors describe their recently developed Computer-aided VIsual Communication (C-VIC) system, and report results of single-subject experimental designs probing its use with five chronic, severely impaired aphasic individuals. Studies replicate earlier results obtained with a non-computerized system, demonstrate patient competence with the computer implementation, extend the system's utility, and identify promising areas of application. Results of the single-subject experimental designs clarify patients' learning, generalization, and retention patterns, and highlight areas of performance difficulties. Future directions for the project are indicated.
A Fast Approach to Automatic Detection of Brain Lesions
Koley, Subhranil; Chakraborty, Chandan; Mainero, Caterina; Fischl, Bruce; Aganj, Iman
2017-01-01
Template matching is a popular approach to computer-aided detection of brain lesions from magnetic resonance (MR) images. The outcomes are often sufficient for localizing lesions and assisting clinicians in diagnosis. However, processing large MR volumes with three-dimensional (3D) templates is demanding in terms of computational resources, hence the importance of the reduction of computational complexity of template matching, particularly in situations in which time is crucial (e.g. emergent stroke). In view of this, we make use of 3D Gaussian templates with varying radii and propose a new method to compute the normalized cross-correlation coefficient as a similarity metric between the MR volume and the template to detect brain lesions. Contrary to the conventional fast Fourier transform (FFT) based approach, whose runtime grows as O(N logN) with the number of voxels, the proposed method computes the cross-correlation in O(N). We show through our experiments that the proposed method outperforms the FFT approach in terms of computational time, and retains comparable accuracy. PMID:29082383
2002-08-01
demonstrated in three-dimensional graphics and animations. This computer model will aid in planning of non-operative or operative management, rehabilitation regimens, nursing programs, and patient education .
NASA Technical Reports Server (NTRS)
Hegarty, D. M.
1974-01-01
A guidance, navigation, and control system, the Simulated Shuttle Flight Test System (SS-FTS), when interfaced with existing aircraft systems, provides a research facility for studying concepts for landing the space shuttle orbiter and conventional jet aircraft. The SS-FTS, which includes a general-purpose computer, performs all computations for precisely following a prescribed approach trajectory while properly managing the vehicle energy to allow safe arrival at the runway and landing within prescribed dispersions. The system contains hardware and software provisions for navigation with several combinations of possible navigation aids that have been suggested for the shuttle. The SS-FTS can be reconfigured to study different guidance and navigation concepts by changing only the computer software, and adapted to receive different radio navigation information through minimum hardware changes. All control laws, logic, and mode interlocks reside solely in the computer software.
ERIC Educational Resources Information Center
Kalanda, Boniface; Mamimine, Patrick; Taela, Katia; Chingandu, Louis; Musuka, Godfrey
2010-01-01
The governments across the world have endorsed numerous international Conventions and Declarations (C&Ds) that enhance interventions to reduce the impact of HIV and AIDS. The objective of this study was to assess the extent to which the governments of Lesotho, Malawi and Mozambique have implemented HIV and AIDS international and regional…
Is computer-aided interpretation of 99Tcm-HMPAO leukocyte scans better than the naked eye?
Almer, S; Peters, A M; Ekberg, S; Franzén, L; Granerus, G; Ström, M
1995-04-01
In order to compare visual interpretation of inflammation detected by leukocyte scintigraphy with that of different computer-aided quantification methods, 34 patients (25 with ulcerative colitis and 9 with endoscopically verified non-inflamed colonic mucosa), were investigated using 99Tcm-hexamethylpropyleneamine oxime (99Tcm-HMPAO) leukocyte scintigraphy and colonoscopy with biopsies. Scintigrams were obtained 45 min and 4 h after the injection of labelled cells. Computer-generated grading of seven colon segments using four different methods was performed on each scintigram for each patient. The same segments were graded independently using a 4-point visual scale. Endoscopic and histological inflammation were scored on 4-point scales. At 45 min, a positive correlation was found between endoscopic and scan gradings in individual colon segments when using visual grading and three of the four computer-aided methods (Spearman's rs = 0.30-0.64, P < 0.001). Histological grading correlated with visual grading and with two of the four computer-aided methods at 45 min (rs = 0.42-0.54, P < 0.001). At 4 h, all grading methods correlated positively with both endoscopic and histological assessment. The correlation coefficients were, in all but one instance, highest for the visual grading. As an inter-observer comparison to assess agreement between the visual gradings of two nuclear physicians, 14 additional patients (9 ulcerative colitis, 5 infectious enterocolitis) underwent leukocyte scintigraphy. Agreement assessed using kappa statistics was 0.54 at 45 min (P < 0.001). Separate data concerning the presence/absence of active inflammation showed a high kappa value (0.74, P < 0.001). Our results showed that a simple scintigraphic scoring system based on assessment using the human eye reflects colonic inflammation at least as well as computer-aided grading, and that highly correlated results can be achieved between different investigators.
ERIC Educational Resources Information Center
Tsai, Shu-Chiao
2011-01-01
This study reports on the integration of English for Specific Purposes (ESP) multimedia courseware for oral presentations into a self-learning and elective program for non-English major students in an English as a Foreign Language (EFL) setting. A computer-aided instruction approach, combined with a task-based learning approach, was adopted.…
Computer-Aided Facilities Management Systems (CAFM).
ERIC Educational Resources Information Center
Cyros, Kreon L.
Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…
Multiple neural network approaches to clinical expert systems
NASA Astrophysics Data System (ADS)
Stubbs, Derek F.
1990-08-01
We briefly review the concept of computer aided medical diagnosis and more extensively review the the existing literature on neural network applications in the field. Neural networks can function as simple expert systems for diagnosis or prognosis. Using a public database we develop a neural network for the diagnosis of a major presenting symptom while discussing the development process and possible approaches. MEDICAL EXPERTS SYSTEMS COMPUTER AIDED DIAGNOSIS Biomedicine is an incredibly diverse and multidisciplinary field and it is not surprising that neural networks with their many applications are finding more and more applications in the highly non-linear field of biomedicine. I want to concentrate on neural networks as medical expert systems for clinical diagnosis or prognosis. Expert Systems started out as a set of computerized " ifthen" rules. Everything was reduced to boolean logic and the promised land of computer experts was said to be in sight. It never came. Why? First the computer code explodes as the number of " ifs" increases. All the " ifs" have to interact. Second experts are not very good at reducing expertise to language. It turns out that experts recognize patterns and have non-verbal left-brain intuition decision processes. Third learning by example rather than learning by rule is the way natural brains works and making computers work by rule-learning is hideously labor intensive. Neural networks can learn from example. They learn the results
Quantitative assessment of commercial filter 'aids' for red-green colour defectives.
Moreland, Jack D; Westland, Steven; Cheung, Vien; Dain, Steven J
2010-09-01
The claims made for 43 commercial filter 'aids', that they improve the colour discrimination of red-green colour defectives, are assessed for protanomaly and deuteranomaly by changes in the colour spacing of traffic signals (European Standard EN 1836:2005) and of the Farnsworth D15 test. Spectral transmittances of the 'aids' are measured and tristimulus values with and without 'aids' are computed using cone fundamentals and the spectral power distributions of either the D15 chips illuminated by CIE Illuminant C or of traffic signals. Chromaticities (l,s) are presented in cone excitation diagrams for protanomaly and deuteranomaly in terms of the relative excitation of their long (L), medium (M) and short (S) wavelength-sensitive cones. After correcting for non-uniform colour spacing in these diagrams, standard deviations parallel to the l and s axes are computed and enhancement factors E(l) and E(s) are derived as the ratio of 'aided' to 'unaided' standard deviations. Values of E(l) for traffic signals with most 'aids' are <1 and many do not meet the European signal detection standard. A few 'aids' have expansive E(l) factors but with inadequate utility: the largest being 1.2 for traffic signals and 1.3 for the D15 colours. Analyses, replicated for 19 'aids' from one manufacturer using 658 Munsell colours inside the D15 locus, yield E(l) factors within 1% of those found for the 16 D15 colours. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.
Development of a CAD Model Simplification Framework for Finite Element Analysis
2012-01-01
A. Senthil Kumar , and KH Lee. Automatic solid decomposition and reduction for non-manifold geometric model generation. Computer-Aided Design, 36(13...CAD/CAM: concepts, techniques, and applications. Wiley-interscience, 1995. [38] Avneesh Sud, Mark Foskey, and Dinesh Manocha. Homotopy-preserving
ERIC Educational Resources Information Center
Hagge, John
1986-01-01
Focuses on problems encountered with computer-aided writing instruction. Discusses conflicts caused by the computer classroom concept, some general paradoxes and ethical implications of computer-aided instruction. (EL)
Project-Based Teaching-Learning Computer-Aided Engineering Tools
ERIC Educational Resources Information Center
Simoes, J. A.; Relvas, C.; Moreira, R.
2004-01-01
Computer-aided design, computer-aided manufacturing, computer-aided analysis, reverse engineering and rapid prototyping are tools that play an important key role within product design. These are areas of technical knowledge that must be part of engineering and industrial design courses' curricula. This paper describes our teaching experience of…
Arslan, Mustafa; Murat, Sema; Alp, Gulce; Zaimoglu, Ali
2018-01-01
The objectives of this in vitro study were to evaluate the flexural strength (FS), surface roughness (Ra), and hydrophobicity of polymethylmethacrylate (PMMA)-based computer-aided design/computer-aided manufacturing (CAD/CAM) polymers and to compare the properties of different CAD/CAM PMMA-based polymers with conventional heat-polymerized PMMA following thermal cycling. Twenty rectangular-shaped specimens (64 × 10 × 3.3 mm) were fabricated from three CAD/CAM PMMA-based polymers (M-PM Disc [M], AvaDent Puck Disc [A], and Pink CAD/CAM Disc Polident [P], and one conventional heat-polymerized PMMA (Promolux [C]), according to ISO 20795-1:2013 standards. The specimens were divided into two subgroups (n = 10), a control and a thermocycled group. The specimens in the thermocycled group were subjected to 5000 thermal cycling procedures (5 to 55°C; 30 s dwell times). The Ra value was measured using a profilometer. Contact angle (CA) was assessed using the sessile drop method to evaluate surface hydrophobicity. In addition, the FS of the specimens was tested in a universal testing machine at a crosshead speed of 1.0 mm/min. Surface texture of the materials was assessed using scanning electron microscope (SEM). The data were analyzed using two-way analysis of variance (ANOVA), followed by Tukey's HSD post-hoc test (α < 0.05). CAD/CAM PMMA-based polymers showed significantly higher FS than conventional heat-polymerized PMMA for each group (P < 0.001). CAD/CAM PMMA-based polymer [P] showed the highest FS, whereas conventional PMMA [C] showed the lowest FS before and after thermal cycling (P < 0.001). There were no significant differences among the Ra values of the tested denture base polymers in the control group (P > 0.05). In the thermocycled group, the lowest Ra value was observed for CAD/CAM PMMA-based polymer [M] (P < 0.001), whereas CAD/CAM PMMA-based polymers [A] and [P], and conventional PMMA [C] had similar Ra values (P > 0.05). Conventional PMMA [C] had a significantly lower CA and consequently lower hydrophobicity compared to the CAD/CAM polymers in the control group (P < 0.001). In the thermocycled group, CAD/CAM PMMA-based polymer [A] and conventional PMMA [C] had significantly higher CA, and consequently higher hydrophobicity when compared to CAD/CAM polymers [M] and [P] (P < 0.001). However, no significant differences were found among the other materials (P > 0.05). The FS and hydrophobicity of the CAD/CAM PMMA-based polymers were higher than the conventional heat-polymerized PMMA, whereas the CAD/CAM PMMA-based polymers had similar Ra values to the conventional PMMA. Thermocycling had a significant effect on FS and hydrophobicity except for the Ra of denture base materials.
Interactive computer aided technology, evolution in the design/manufacturing process
NASA Technical Reports Server (NTRS)
English, C. H.
1975-01-01
A powerful computer-operated three dimensional graphic system and associated auxiliary computer equipment used in advanced design, production design, and manufacturing was described. This system has made these activities more productive than when using older and more conventional methods to design and build aerospace vehicles. With the use of this graphic system, designers are now able to define parts using a wide variety of geometric entities, define parts as fully surface 3-dimensional models as well as "wire-frame" models. Once geometrically defined, the designer is able to take section cuts of the surfaced model and automatically determine all of the section properties of the planar cut, lightpen detect all of the surface patches and automatically determine the volume and weight of the part. Further, his designs are defined mathematically at a degree of accuracy never before achievable.
Automated and real-time segmentation of suspicious breast masses using convolutional neural network
Gregory, Adriana; Denis, Max; Meixner, Duane D.; Bayat, Mahdi; Whaley, Dana H.; Fatemi, Mostafa; Alizad, Azra
2018-01-01
In this work, a computer-aided tool for detection was developed to segment breast masses from clinical ultrasound (US) scans. The underlying Multi U-net algorithm is based on convolutional neural networks. Under the Mayo Clinic Institutional Review Board protocol, a prospective study of the automatic segmentation of suspicious breast masses was performed. The cohort consisted of 258 female patients who were clinically identified with suspicious breast masses and underwent clinical US scan and breast biopsy. The computer-aided detection tool effectively segmented the breast masses, achieving a mean Dice coefficient of 0.82, a true positive fraction (TPF) of 0.84, and a false positive fraction (FPF) of 0.01. By avoiding positioning of an initial seed, the algorithm is able to segment images in real time (13–55 ms per image), and can have potential clinical applications. The algorithm is at par with a conventional seeded algorithm, which had a mean Dice coefficient of 0.84 and performs significantly better (P< 0.0001) than the original U-net algorithm. PMID:29768415
Computer aided detection system for lung cancer using computer tomography scans
NASA Astrophysics Data System (ADS)
Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.
2018-04-01
Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.
Servo-controlling structure of five-axis CNC system for real-time NURBS interpolating
NASA Astrophysics Data System (ADS)
Chen, Liangji; Guo, Guangsong; Li, Huiying
2017-07-01
NURBS (Non-Uniform Rational B-Spline) is widely used in CAD/CAM (Computer-Aided Design / Computer-Aided Manufacturing) to represent sculptured curves or surfaces. In this paper, we develop a 5-axis NURBS real-time interpolator and realize it in our developing CNC(Computer Numerical Control) system. At first, we use two NURBS curves to represent tool-tip and tool-axis path respectively. According to feedrate and Taylor series extension, servo-controlling signals of 5 axes are obtained for each interpolating cycle. Then, generation procedure of NC(Numerical Control) code with the presented method is introduced and the method how to integrate the interpolator into our developing CNC system is given. And also, the servo-controlling structure of the CNC system is introduced. Through the illustration, it has been indicated that the proposed method can enhance the machining accuracy and the spline interpolator is feasible for 5-axis CNC system.
Development of concepts on the interaction of drugs with opioid receptors
NASA Astrophysics Data System (ADS)
Kuzmina, N. E.; Kuzmin, V. S.
2011-02-01
The development of concepts on the molecular mechanisms of the action of medicinal drugs on the opioid receptors is briefly surveyed. The modern point of view on the mechanism of activation of opioid receptors is given based on the data from chimeric and site-directed mutagenesis of the cloned opioid receptors and the computer-aided simulations of the reception zone and ligand-receptor complexes. Three-dimensional models of the opioid pharmacophore derived by both conventional methods and a comparative analysis of molecular fields are described in detail.
The ERTS-1 investigation (ER-600). Volume 3: ERTS-1 forest analysis
NASA Technical Reports Server (NTRS)
Erb, R. B.
1974-01-01
The Forest Analysis Team of the Lyndon B. Johnson Space Center Earth Observations Division conducted a year's investigation of LANDSAT 1 multispectral data to determine the size of forest features that could be detected and to determine the suitability for making forest classification maps. The Sam Houston National Forest of Texas was used as the test site. Using conventional interpretation and computer aided techniques, the team was able to differentiate up to 14 classes of forest features to an accuracy ranging between 55 and 84 percent.
Software For Computing Reliability Of Other Software
NASA Technical Reports Server (NTRS)
Nikora, Allen; Antczak, Thomas M.; Lyu, Michael
1995-01-01
Computer Aided Software Reliability Estimation (CASRE) computer program developed for use in measuring reliability of other software. Easier for non-specialists in reliability to use than many other currently available programs developed for same purpose. CASRE incorporates mathematical modeling capabilities of public-domain Statistical Modeling and Estimation of Reliability Functions for Software (SMERFS) computer program and runs in Windows software environment. Provides menu-driven command interface; enabling and disabling of menu options guides user through (1) selection of set of failure data, (2) execution of mathematical model, and (3) analysis of results from model. Written in C language.
Kim, Min-Beom; Chung, Won-Ho; Choi, Jeesun; Hong, Sung Hwa; Cho, Yang-Sun; Park, Gyuseok; Lee, Sangmin
2014-06-01
The object was to evaluate speech perception improvement through Bluetooth-implemented hearing aids in hearing-impaired adults. Thirty subjects with bilateral symmetric moderate sensorineural hearing loss participated in this study. A Bluetooth-implemented hearing aid was fitted unilaterally in all study subjects. Objective speech recognition score and subjective satisfaction were measured with a Bluetooth-implemented hearing aid to replace the acoustic connection from either a cellular phone or a loudspeaker system. In each system, participants were assigned to 4 conditions: wireless speech signal transmission into hearing aid (wireless mode) in quiet or noisy environment and conventional speech signal transmission using external microphone of hearing aid (conventional mode) in quiet or noisy environment. Also, participants completed questionnaires to investigate subjective satisfaction. Both cellular phone and loudspeaker system situation, participants showed improvements in sentence and word recognition scores with wireless mode compared to conventional mode in both quiet and noise conditions (P < .001). Participants also reported subjective improvements, including better sound quality, less noise interference, and better accuracy naturalness, when using the wireless mode (P < .001). Bluetooth-implemented hearing aids helped to improve subjective and objective speech recognition performances in quiet and noisy environments during the use of electronic audio devices.
NASA Technical Reports Server (NTRS)
Bejczy, Antal K.
1995-01-01
This presentation focuses on the application of computer graphics or 'virtual reality' (VR) techniques as a human-computer interface tool in the operation of telerobotic systems. VR techniques offer very valuable task realization aids for planning, previewing and predicting robotic actions, operator training, and for visual perception of non-visible events like contact forces in robotic tasks. The utility of computer graphics in telerobotic operation can be significantly enhanced by high-fidelity calibration of virtual reality images to actual TV camera images. This calibration will even permit the creation of artificial (synthetic) views of task scenes for which no TV camera views are available.
ERIC Educational Resources Information Center
Owusu, K. A.; Monney, K. A.; Appiah, J. Y.; Wilmot, E. M.
2010-01-01
This study investigated the comparative efficiency of computer-assisted instruction (CAI) and conventional teaching method in biology on senior high school students. A science class was selected in each of two randomly selected schools. The pretest-posttest non equivalent quasi experimental design was used. The students in the experimental group…
Space shuttle post-entry and landing analysis. Volume 1: Candidate system evaluations
NASA Technical Reports Server (NTRS)
Crawford, B. S.; Duiven, E. M.
1973-01-01
The general purpose of this study is to aid in the evaluation and design of multi-sensor navigation schemes proposed for the orbiter. The scope of the effort is limited to the post-entry, energy management, and approach and landing mission phases. One candidate system based on conventional navigation aids is illustrated including two DME (Distance Measuring Equipment) stations and ILS (Instrument Landing System) glide slope and localizer antennas. Some key elements of the system not shown are the onboard IMUs (Inertial Measurement Units), altimeters, and a computer. The latter is programmed to mix together (filter) the IMU data and the externally-derived data. A completely automatic, all-weather landing capability is required. Since no air-breathing engines will be carried on orbital flights, there will be no chance to go around and try again following a missed approach.
ERIC Educational Resources Information Center
Georgia Univ., Athens. Div. of Vocational Education.
This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…
Employment Opportunities for the Handicapped in Programmable Automation.
ERIC Educational Resources Information Center
Swift, Richard; Leneway, Robert
A Computer Integrated Manufacturing System may make it possible for severely disabled people to custom design, machine, and manufacture either wood or metal parts. Programmable automation merges computer aided design, computer aided manufacturing, computer aided engineering, and computer integrated manufacturing systems with automated production…
Textile Visual Materials: Appropriate Technology in Action.
ERIC Educational Resources Information Center
Donoghue, Beverly Emerson
An innovative educational medium--screenprinted visual aids on cloth--is one alternative to conventional media in Africa, where visual materials are important communication tools but conventional media and materials are often scarce. A production process for cloth visual aids was developed and evaluated in Ghana and Sudan through the…
Computer-aided diagnosis in radiological imaging: current status and future challenges
NASA Astrophysics Data System (ADS)
Doi, Kunio
2009-10-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. Many different types of CAD schemes are being developed for detection and/or characterization of various lesions in medical imaging, including conventional projection radiography, CT, MRI, and ultrasound imaging. Commercial systems for detection of breast lesions on mammograms have been developed and have received FDA approval for clinical use. CAD may be defined as a diagnosis made by a physician who takes into account the computer output as a "second opinion". The purpose of CAD is to improve the quality and productivity of physicians in their interpretation of radiologic images. The quality of their work can be improved in terms of the accuracy and consistency of their radiologic diagnoses. In addition, the productivity of radiologists is expected to be improved by a reduction in the time required for their image readings. The computer output is derived from quantitative analysis of radiologic images by use of various methods and techniques in computer vision, artificial intelligence, and artificial neural networks (ANNs). The computer output may indicate a number of important parameters, for example, the locations of potential lesions such as lung cancer and breast cancer, the likelihood of malignancy of detected lesions, and the likelihood of various diseases based on differential diagnosis in a given image and clinical parameters. In this review article, the basic concept of CAD is first defined, and the current status of CAD research is then described. In addition, the potential of CAD in the future is discussed and predicted.
The Kibble-Zurek mechanism in phase transitions of non-equilibrium systems
NASA Astrophysics Data System (ADS)
Cheung, Hil F. H.; Patil, Yogesh S.; Date, Aditya G.; Vengalattore, Mukund
2017-04-01
We experimentally realize a driven-dissipative phase transition using a mechanical parametric amplifier to demonstrate key signatures of a second order phase transition, including a point where the susceptibilities and relaxation time scales diverge, and where the system exhibits a spontaneous breaking of symmetry. Though reminiscent of conventional equilibrium phase transitions, it is unclear if such driven-dissipative phase transitions are amenable to the conventional Landau-Ginsburg-Wilson paradigm, which relies on concepts of scale invariance and universality, and recent work has shown that such phase transitions can indeed lie beyond such conventional universality classes. By quenching the system past the critical point, we investigate the dynamics of the emergent ordered phase and find that our measurements are in excellent agreement with the Kibble-Zurek mechanism. In addition to verifying the Kibble-Zurek hypothesis in driven-dissipative phase transitions for the first time, we also demonstrate that the measured critical exponents accurately reflect the interplay between intrinsic coherent dynamics and environmental correlations, showing a clear departure from mean field exponents in the case of non-Markovian system-bath interactions. We further discuss how reservoir engineering and the imposition of artificial environmental correlations can result in the stabilization of novel many-body quantum phases and aid in the creation of exotic non-equilibrium states of matter.
Hsiao, Chien-Yu; Sung, Hsin-Ching; Hu, Sindy; Huang, Chun-Hsun
2016-07-01
Laser pretreatment of skin can be used to enable drugs used in dermatology to penetrate the skin to the depth necessary for their effect to take place. To compare the permeation of tranexamic acid after conventional non-fractionated ablative Er:YAG and CO2 laser pretreatment in a laser-aided transdermal delivery system. An erbium-doped yttrium aluminium garnet (Er:YAG) and a CO2 laser were used to pretreat dorsal porcine skin. Scanning electron microscopy was used to examine disruption of the skin surface. Confocal laser scanning microscopy was used to determine the depth of penetration of a reporter molecule (fluorescein isothiocyanate) into the skin. A Franz diffusion assembly was used to examine fluency-related increases in transdermal delivery of transexamic acid. Transdermal delivery of tranexamic acid increased as Er:YAG laser fluency increased. Transdermal delivery was higher when CO2 laser pretreatment was used than when Er:YAG laser pretreatment was used, but a "ceiling effect" was present and increasing the wattage did not cause a further increase in delivery. CO2 laser pretreatment also caused more extensive and deeper skin disruption than Er:YAG laser pretreatment. For conventional, non-fractionated ablative laser pretreatment, the Er:YAG laser would be an optimal choice to enhance transdermal penetration of transexamic acid.
Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.
Stawarczyk, Bogna; Lümkemann, Nina; Eichberger, Marlis; Wimmer, Timea
2017-12-19
The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x -, y - and z -axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.
Computer-aided detection of basal cell carcinoma through blood content analysis in dermoscopy images
NASA Astrophysics Data System (ADS)
Kharazmi, Pegah; Kalia, Sunil; Lui, Harvey; Wang, Z. Jane; Lee, Tim K.
2018-02-01
Basal cell carcinoma (BCC) is the most common type of skin cancer, which is highly damaging to the skin at its advanced stages and causes huge costs on the healthcare system. However, most types of BCC are easily curable if detected at early stage. Due to limited access to dermatologists and expert physicians, non-invasive computer-aided diagnosis is a viable option for skin cancer screening. A clinical biomarker of cancerous tumors is increased vascularization and excess blood flow. In this paper, we present a computer-aided technique to differentiate cancerous skin tumors from benign lesions based on vascular characteristics of the lesions. Dermoscopy image of the lesion is first decomposed using independent component analysis of the RGB channels to derive melanin and hemoglobin maps. A novel set of clinically inspired features and ratiometric measurements are then extracted from each map to characterize the vascular properties and blood content of the lesion. The feature set is then fed into a random forest classifier. Over a dataset of 664 skin lesions, the proposed method achieved an area under ROC curve of 0.832 in a 10-fold cross validation for differentiating basal cell carcinomas from benign lesions.
K, Jalal Deen; R, Ganesan; A, Merline
2017-07-27
Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. Creative Commons Attribution License
Gastrointestinal robot-assisted surgery. A current perspective.
Lunca, Sorinel; Bouras, George; Stanescu, Alexandru Calin
2005-12-01
Minimally invasive techniques have revolutionized operative surgery. Computer aided surgery and robotic surgical systems strive to improve further on currently available minimally invasive surgery and open new horizons. Only several centers are currently using surgical robots and publishing data. In gastrointestinal surgery, robotic surgery is applied to a wide range of procedures, but is still in its infancy. Cholecystectomy, Nissen fundoplication and Heller myotomy are among the most frequently performed operations. The ZEUS (Computer Motion, Goleta, CA) and the da Vinci (Intuitive Surgical, Mountain View, CA) surgical systems are today the most advanced robotic systems used in gastrointestinal surgery. Most studies reported that robotic gastrointestinal surgery is feasible and safe, provides improved dexterity, better visualization, reduced fatigue and high levels of precision when compared to conventional laparoscopic surgery. Its main drawbacks are the absence of force feedback and extremely high costs. At this moment there are no reports to clearly demonstrate the superiority of robotics over conventional laparoscopic surgery. Further research and more prospective randomized trials are needed to better define the optimal application of this new technology in gastrointestinal surgery.
K, Jalal Deen; R, Ganesan; A, Merline
2017-01-01
Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. PMID:28749127
ERIC Educational Resources Information Center
Havas, George D.
This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…
Vamsy, Mohana; Dattatreya, PS; Parakh, Megha; Dayal, Monal; Rao, VVS Prabhakar
2013-01-01
Primary testicular lymphoma (PTL) a relatively rare disease of non-Hodgkin's lymphomas occurring with a lesser incidence of 1-2% has a propensity to occur at later ages above 50 years. PTL spreads to extra nodal sites due to deficiency of extra cellular adhesion molecules. We present detection of multiple sites of extra nodal involvement of PTL by F-18 positron emission tomography/computed tomography study aiding early detection of the dissemination thus aiding in staging and management. PMID:24019676
Student Achievement in Computer Programming: Lecture vs Computer-Aided Instruction
ERIC Educational Resources Information Center
Tsai, San-Yun W.; Pohl, Norval F.
1978-01-01
This paper discusses a study of the differences in student learning achievement, as measured by four different types of common performance evaluation techniques, in a college-level computer programming course under three teaching/learning environments: lecture, computer-aided instruction, and lecture supplemented with computer-aided instruction.…
Alqahtani, Fawaz
2017-01-01
Objective The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. Study design This is an in vitro interventional study. Place and duration of study The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. Methodology A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). Results The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. Conclusion It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap. PMID:28352204
Matta, Ragai-Edward; Bergauer, Bastian; Adler, Werner; Wichmann, Manfred; Nickenig, Hans-Joachim
2017-06-01
The use of a surgical template is a well-established method in advanced implantology. In addition to conventional fabrication, computer-aided design and computer-aided manufacturing (CAD/CAM) work-flow provides an opportunity to engineer implant drilling templates via a three-dimensional printer. In order to transfer the virtual planning to the oral situation, a highly accurate surgical guide is needed. The aim of this study was to evaluate the impact of the fabrication method on the three-dimensional accuracy. The same virtual planning based on a scanned plaster model was used to fabricate a conventional thermo-formed and a three-dimensional printed surgical guide for each of 13 patients (single tooth implants). Both templates were acquired individually on the respective plaster model using an optical industrial white-light scanner (ATOS II, GOM mbh, Braunschweig, Germany), and the virtual datasets were superimposed. Using the three-dimensional geometry of the implant sleeve, the deviation between both surgical guides was evaluated. The mean discrepancy of the angle was 3.479° (standard deviation, 1.904°) based on data from 13 patients. Concerning the three-dimensional position of the implant sleeve, the highest deviation was in the Z-axis at 0.594 mm. The mean deviation of the Euclidian distance, dxyz, was 0.864 mm. Although the two different fabrication methods delivered statistically significantly different templates, the deviations ranged within a decimillimeter span. Both methods are appropriate for clinical use. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Nejatidanesh, Farahnaz; Shakibamehr, Amir Hossein; Savabi, Omid
2016-02-01
To evaluate the accuracy of marginal and internal adaptation of 2 computer-aided design/computer-aided manufacturing (CAD/CAM) and 2 conventionally made cement retained implant-supported restorations. An abutment and its corresponding fixture analog (Astra Tech) were inserted in left central incisor area of a maxillary cast. Four types of implant-supported single restorations were fabricated on the abutment (n = 10): e.max CAD (Cerec AC system), zirconia-based (Cercon system), IPS e.max Press, and metal-ceramic restorations. The internal and marginal gaps of the studied groups were measured by replica method and stereomicroscope. Data were subjected to 1-way ANOVA and Scheffe post hoc tests (α = 0.05). Mean internal gaps of Cercon (59.48 ± 16.49 μm) and e.max Press (75.62 ± 26.92 μm) groups were significantly different from e.max CAD (120.29 ± 16.74 μm) group, but there was no significant difference between metal-ceramic restorations (89.65 ± 47.84 μm) and e.max CAD. The marginal gaps of e.max CAD (32.02 ± 10.38 μm) and Cercon restorations (34.26 ± 11.41 μm) were significantly superior from metal ceramics (59.19 ± 17.81 μm) and e.max press (74.99 ± 24.51 μm). Within the limitations of this study, it can be concluded that although the marginal and internal gaps of the studied implant-supported restorations were in the clinically acceptable range, single crowns made with CAD/CAM technology provide better marginal fit.
Critical Problems in Very Large Scale Computer Systems
1990-03-31
Srinivas Devadas (617) 253-0454 Thomas F. Knight, Jr. (617) 253-7807 F. Thomson Leighton (617) 253-3662 Charles E. Leiserson (617) 253-5833 Jacob K...Aided Design of Integrated Circuits and Systems, pages 19-29, January 1990. [5] S. Arora, T. Leighton, and B . Maggs. On-line algorithms for path...selection in a non-blocking network. In Proceedings of the 21st Annual ACM Symposium on Theory of Computing, May 1990. To appear. [6] P. Ashar, S. Devadas
Computer-aided analysis for the Mechanics of Granular Materials (MGM) experiment, part 2
NASA Technical Reports Server (NTRS)
Parker, Joey K.
1987-01-01
Computer vision based analysis for the MGM experiment is continued and expanded into new areas. Volumetric strains of granular material triaxial test specimens have been measured from digitized images. A computer-assisted procedure is used to identify the edges of the specimen, and the edges are used in a 3-D model to estimate specimen volume. The results of this technique compare favorably to conventional measurements. A simplified model of the magnification caused by diffraction of light within the water of the test apparatus was also developed. This model yields good results when the distance between the camera and the test specimen is large compared to the specimen height. An algorithm for a more accurate 3-D magnification correction is also presented. The use of composite and RGB (red-green-blue) color cameras is discussed and potentially significant benefits from using an RGB camera are presented.
Production and characterization of pure cryogenic inertial fusion targets
NASA Astrophysics Data System (ADS)
Boyd, B. A.; Kamerman, G. W.
An experimental cryogenic inertial fusion target generator and two optical techniques for automated target inspection are described. The generator produces 100 microns diameter solid hydrogen spheres at a rate compatible with fueling requirements of conceptual inertial fusion power plants. A jet of liquified hydrogen is disrupted into droplets by an ultrasonically excited nozzle. The droplets solidify into microspheres while falling through a chamber maintained below the hydrogen triple point pressure. Stable operation of the generator has been demonstrated for up to three hours. The optical inspection techniques are computer aided photomicrography and coarse diffraction pattern analysis (CDPA). The photomicrography system uses a conventional microscope coupled to a computer by a solid state camera and digital image memory. The computer enhances the stored image and performs feature extraction to determine pellet parameters. The CDPA technique uses Fourier transform optics and a special detector array to perform optical processing of a target image.
Silicon Wafer Advanced Packaging (SWAP). Multichip Module (MCM) Foundry Study. Version 2
1991-04-08
Next Layer Dielectric Spacing - Additional Metal Thickness Impact on Dielectric Uniformity/Adhiesion. The first step in .!Ie EPerimental design would be... design CAM - computer aided manufacturing CAE - computer aided engineering CALCE - computer aided life cycle engineering center CARMA - computer aided...expansion 5 j- CVD - chemical vapor deposition J . ..- j DA - design automation J , DEC - Digital Equipment Corporation --- DFT - design for testability
The application of computer-aided technologies in automotive styling design
NASA Astrophysics Data System (ADS)
Zheng, Ze-feng; Zhang, Ji; Zheng, Ying
2012-04-01
In automotive industry, outline design is its life and creative design is its soul indeed. Computer-aided technology has been widely used in the automotive industry and more and more attention has been paid. This paper chiefly introduce the application of computer-aided technologies including CAD, CAM and CAE, analyses the process of automotive structural design and describe the development tendency of computer-aided design.
NASA Astrophysics Data System (ADS)
Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.
2018-04-01
Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.
Tian, J H; Di, P; Lin, Y; Zhang, Y; Wei, D H; Cui, H Y
2017-01-09
Objective: To evaluate the primary clinical outcomes of immediate provisionalization with a monolithic crown utilizing a novel chairside computer aided design and computer aided manufacture (CAD/CAM) workflow for single tooth immediate implant placement. Methods: This pilot study was a prospective within-subjects design. Thirteen consecutive patients were included and diagnosed with untreatable single incisor or premolar with fine general and local anatomical conditions. The trial was conducted at Department of Implantology, Peking University School and Hospital of Stomatology, Beijing, between January 2016 and June 2016. The teeth were extracted atraumatically and implants were immediately placed in the fresh sockets. Two screw-retained interim crowns were fabricated for the same site utilizing different workflows, a monolithic lithium disilicate (LS2) crown produced by CEREC (Sirona, Germany) chairside CAD/CAM system (CER group) and a manually fabricated resin crown utilizing conventional workflow (CONV group) respectively. The patients were blinded to the group allocation of the two interim crowns. After the clinical try-in for both crowns in a randomized sequence, the patients ' level of satisfaction was assessed with a virtual analogue scale (VAS) questionnaire. The restorations chosen by patients themselves were seated in the implants by one experienced prosthodontist. The accuracy, aesthetic effect and clinical time consumption of both groups were compared. Statistical analyses were performed with the Wilcoxon signed rank test. Results: All patients were treated with atraumatic tooth extraction, immediate implant placement using flapless surgery and immediate provisionalization in a single visit. The interim crowns of both groups could be fitted with or without slight adjustments. For each patient, the interim crown of CER group was chosen to be seated with a relatively higher VAS result. The white esthetic score (WES) results demonstrated no statistically significant difference between CER group (7.5±1.1) and CONV group (7.9±0.9) ( P> 0.05). The mean total work time was significantly different resulting in (131.9±5.0) min for CER group and (205.2±6.3) min( P< 0.05). The major difference lied in the laboratory work time, resulting in (113.5±6.3) min for CER group which was significantly shorter than (185.6±6.6) min for CONV group. As for impression taking time, the CER group (7.5±0.8) min was significantly shorter than CONV group (11.7± 1.1) min ( P< 0.05). However, analysis for clinical adjustment time showed a significantly longer time for CER group [(11.0±2.1) min vs (8.0±2.8) min, P< 0.05]. After 3-6 months of observation, the overall survival rate was 100%. Screw loosening occurred in 4 patients and was tightened again. No other major complication soccurred. Conclusions: The full digital workflow utilizing CEREC chairside CAD/CAM system to fabricate interim crowns after immediate implant placement in one single visit was feasible. It was more time-efficient and could effectively shorten the laboratory work time compared to the conventional workflow. Patients demonstrated high satisfaction and there was no statistical difference in WES results compared to the conventional workflow. Favorable clinical outcomes were gained in this short-term follow-up study.
Using 3D computer simulations to enhance ophthalmic training.
Glittenberg, C; Binder, S
2006-01-01
To develop more effective methods of demonstrating and teaching complex topics in ophthalmology with the use of computer aided three-dimensional (3D) animation and interactive multimedia technologies. We created 3D animations and interactive computer programmes demonstrating the neuroophthalmological nature of the oculomotor system, including the anatomy, physiology and pathophysiology of the extra-ocular eye muscles and the oculomotor cranial nerves, as well as pupillary symptoms of neurological diseases. At the University of Vienna we compared their teaching effectiveness to conventional teaching methods in a comparative study involving 100 medical students, a multiple choice exam and a survey. The comparative study showed that our students achieved significantly better test results (80%) than the control group (63%) (diff. = 17 +/- 5%, p = 0.004). The survey showed a positive reaction to the software and a strong preference to have more subjects and techniques demonstrated in this fashion. Three-dimensional computer animation technology can significantly increase the quality and efficiency of the education and demonstration of complex topics in ophthalmology.
[Computer-supported patient history: a workplace analysis].
Schubiger, G; Weber, D; Winiker, H; Desgrandchamps, D; Imahorn, P
1995-04-29
Since 1991, an extensive computer network has been developed and implemented at the Cantonal Hospital of Lucerne. The medical applications include computer aided management of patient charts, medical correspondence, and compilation of diagnosis statistics according to the ICD-9 code. In 1992, the system was introduced as a pilot project in the departments of pediatrics and pediatric surgery of the Lucerne Children's Hospital. This new system has been prospectively evaluated using a workplace analysis. The time taken to complete patient charts and surgical reports was recorded for 14 days before and after the introduction of the computerized system. This analysis was performed for both physicians and secretarial staff. The time delay between the discharge of the patient and the mailing of the discharge letter to the family doctor was also recorded. By conventional means, the average time for the physician to generate a patient chart (26 minutes, n = 119) was slightly lower than the time needed with the computer system (28 minutes, n = 177). However, for a discharge letter, the time needed by the physician was reduced by one third with the computer system and by more than one half for the secretarial staff (32 and 66 minutes conventionally; 22 and 24 minutes respectively with the computer system; p < 0.0001). The time required for the generation of surgical reports was reduced from 17 to 13 minutes per patient and the processing time by secretaries from 37 to 14 minutes. The time delay between the discharge of the patient and the mailing of the discharge letter was reduced by 50% from 7.6 to 3.9 days.(ABSTRACT TRUNCATED AT 250 WORDS)
Enhancing an appointment diary on a pocket computer for use by people after brain injury.
Wright, P; Rogers, N; Hall, C; Wilson, B; Evans, J; Emslie, H
2001-12-01
People with memory loss resulting from brain injury benefit from purpose-designed memory aids such as appointment diaries on pocket computers. The present study explores the effects of extending the range of memory aids and including games. For 2 months, 12 people who had sustained brain injury were loaned a pocket computer containing three purpose-designed memory aids: diary, notebook and to-do list. A month later they were given another computer with the same memory aids but a different method of text entry (physical keyboard or touch-screen keyboard). Machine order was counterbalanced across participants. Assessment was by interviews during the loan periods, rating scales, performance tests and computer log files. All participants could use the memory aids and ten people (83%) found them very useful. Correlations among the three memory aids were not significant, suggesting individual variation in how they were used. Games did not increase use of the memory aids, nor did loan of the preferred pocket computer (with physical keyboard). Significantly more diary entries were made by people who had previously used other memory aids, suggesting that a better understanding of how to use a range of memory aids could benefit some people with brain injury.
Future Short Range Ground-Based Air Defence: System Drivers, Characteristics and Architectures
2001-03-01
vulnerable being on the right. Although for completeness the defended asset characteristics shown in Table 1 are based upon a conventional armoured formation...Camouflage scrimmed draped visual full/thermal EMCON 4 3 2 1 Visibility line of sight occulting/obscured non line of sight "Contact static FLOT fluid...confused mel~e Armour soft semi-hard hard defensive aids Protection Digging in open under cover dug in full o/h protection AD none AAAD CAD fully
NASA Technical Reports Server (NTRS)
Packard, A. K.; Sastry, S. S.
1986-01-01
A method of solving a class of linear matrix equations over various rings is proposed, using results from linear geometric control theory. An algorithm, successfully implemented, is presented, along with non-trivial numerical examples. Applications of the method to the algebraic control system design methodology are discussed.
Computer-aided design and computer science technology
NASA Technical Reports Server (NTRS)
Fulton, R. E.; Voigt, S. J.
1976-01-01
A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.
Anatomically-Aided PET Reconstruction Using the Kernel Method
Hutchcroft, Will; Wang, Guobao; Chen, Kevin T.; Catana, Ciprian; Qi, Jinyi
2016-01-01
This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest (ROI) quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization (EM) algorithm. PMID:27541810
Anatomically-aided PET reconstruction using the kernel method.
Hutchcroft, Will; Wang, Guobao; Chen, Kevin T; Catana, Ciprian; Qi, Jinyi
2016-09-21
This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization algorithm.
Anatomically-aided PET reconstruction using the kernel method
NASA Astrophysics Data System (ADS)
Hutchcroft, Will; Wang, Guobao; Chen, Kevin T.; Catana, Ciprian; Qi, Jinyi
2016-09-01
This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization algorithm.
NASA Technical Reports Server (NTRS)
Davis, S. J.; Rosenstein, H.
1975-01-01
The Comprehensive Airship Sizing and Performance Computer Program (CASCOMP) is described which was developed and used in the design and evaluation of advanced lighter-than-air (LTA) craft. The program defines design details such as engine size and number, component weight buildups, required power, and the physical dimensions of airships which are designed to meet specified mission requirements. The program is used in a comparative parametric evaluation of six advanced lighter-than-air concepts. The results indicate that fully buoyant conventional airships have the lightest gross lift required when designed for speeds less than 100 knots and the partially buoyant concepts are superior above 100 knots. When compared on the basis of specific productivity, which is a measure of the direct operating cost, the partially buoyant lifting body/tilting prop-rotor concept is optimum.
Computer Instructional Aids for Undergraduate Control Education.
ERIC Educational Resources Information Center
Volz, Richard A.; And Others
Engineering is coming to rely more and more heavily upon the computer for computations, analyses, and graphic displays which aid the design process. A general purpose simulation system, the Time-shared Automatic Control Laboratory (TACL), and a set of computer-aided design programs, Control Oriented Interactive Graphic Analysis and Design…
Längkvist, Martin; Jendeberg, Johan; Thunberg, Per; Loutfi, Amy; Lidén, Mats
2018-06-01
Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
1986-07-01
COMPUTER-AIDED OPERATION MANAGEMENT SYSTEM ................. 29 Functions of an Off-Line Computer-Aided Operation Management System Applications of...System Comparisons 85 DISTRIBUTION 5V J. • 0. FIGURES Number Page 1 Hardware Components 21 2 Basic Functions of a Computer-Aided Operation Management System...Plant Visits 26 4 Computer-Aided Operation Management Systems Reviewed for Analysis of Basic Functions 29 5 Progress of Software System Installation and
Charon Message-Passing Toolkit for Scientific Computations
NASA Technical Reports Server (NTRS)
VanderWijngaart, Rob F.; Yan, Jerry (Technical Monitor)
2000-01-01
Charon is a library, callable from C and Fortran, that aids the conversion of structured-grid legacy codes-such as those used in the numerical computation of fluid flows-into parallel, high- performance codes. Key are functions that define distributed arrays, that map between distributed and non-distributed arrays, and that allow easy specification of common communications on structured grids. The library is based on the widely accepted MPI message passing standard. We present an overview of the functionality of Charon, and some representative results.
Digital receiver study and implementation
NASA Technical Reports Server (NTRS)
Fogle, D. A.; Lee, G. M.; Massey, J. C.
1972-01-01
Computer software was developed which makes it possible to use any general purpose computer with A/D conversion capability as a PSK receiver for low data rate telemetry processing. Carrier tracking, bit synchronization, and matched filter detection are all performed digitally. To aid in the implementation of optimum computer processors, a study of general digital processing techniques was performed which emphasized various techniques for digitizing general analog systems. In particular, the phase-locked loop was extensively analyzed as a typical non-linear communication element. Bayesian estimation techniques for PSK demodulation were studied. A hardware implementation of the digital Costas loop was developed.
NASA Technical Reports Server (NTRS)
Leybold, H. A.
1971-01-01
Random numbers were generated with the aid of a digital computer and transformed such that the probability density function of a discrete random load history composed of these random numbers had one of the following non-Gaussian distributions: Poisson, binomial, log-normal, Weibull, and exponential. The resulting random load histories were analyzed to determine their peak statistics and were compared with cumulative peak maneuver-load distributions for fighter and transport aircraft in flight.
1990-09-01
seats Dining room Parking garage (1 story) Kitchen Required: Prepare a list of live loads for the project. Live load reductions are to be taken for all...Corridor (main) 100 Office: Lobbies 100 Assembly: Mouable seats 100 Dining rooms 100 Garages (passenger cars) 50 Kitchens (non domestic) 150a AI...rooms 100 Garages (passenger cars) 50 Kitchens (non domestic) 150a a. Variable design load. Increase may be necessary. Notes Uniformly distributed live
Biostereometric Data Processing In ERGODATA: Choice Of Human Body Models
NASA Astrophysics Data System (ADS)
Pineau, J. C.; Mollard, R.; Sauvignon, M.; Amphoux, M.
1983-07-01
The definition of human body models was elaborated with anthropometric data from ERGODATA. The first model reduces the human body into a series of points and lines. The second model is well adapted to represent volumes of each segmentary element. The third is an original model built from the conventional anatomical points. Each segment is defined in space by a tri-angular plane located with its 3-D coordinates. This new model can answer all the processing possibilities in the field of computer-aided design (C.A.D.) in ergonomy but also biomechanics and orthopaedics.
Fleury, Eduardo F C; Gianini, Ana Claudia; Marcomini, Karem; Oliveira, Vilmar
2018-01-01
To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted κ test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.
A 250-Mbit/s ring local computer network using 1.3-microns single-mode optical fibers
NASA Technical Reports Server (NTRS)
Eng, S. T.; Tell, R.; Andersson, T.; Eng, B.
1985-01-01
A 250-Mbit/s three-station fiber-optic ring local computer network was built and successfully demonstrated. A conventional token protocol was employed for bus arbitration to maximize the bus efficiency under high loading conditions, and a non-return-to-zero (NRS) data encoding format was selected for simplicity and maximum utilization of the ECL-circuit bandwidth.
The Use of a Microcomputer in Collecting Data from Cardiovascular Experiments on Muscle Relaxants
Thut, Paul D.; Polansky, Gregg; Pruzansky, Elysa
1983-01-01
The possible association of cardiovascular side-effects from potentially, clinically useful non-depolarizing neuromuscular blocking drugs has been studied with the aid of a micro- computer. The maximal changes in heart rate, systolic, diastolic and mean arterial pressure and pulse pressure were recorded in the onset, maximal effect and recovery phase of relaxant activity in dogs anesthetized with isoflurane. The data collection system employed a Gould 2800S polygraph, an Apple II Plus microcomputer, a Cyborg Corp. ‘Issac’ 12 bit analog to digital converter, two 5 1/4″ floppy disk drives, a ‘Videoterm’ 80 column display board and a 12″ green phosphor monitor. Prior to development of the computer system, direct analysis of polygraph records required more than three times more time than the actual experiment. With the aid of the computer, analysis of data, tabular and graphic presentation and narrative reports were completed within 15 minutes after the end of the experiment.
Surface texture and hardness of dental alloys processed by alternative technologies
NASA Astrophysics Data System (ADS)
Porojan, Liliana; Savencu, Cristina E.; Topală, Florin I.; Porojan, Sorin D.
2017-08-01
Technological developments have led to the implementation of novel digitalized manufacturing methods for the production of metallic structures in prosthetic dentistry. These technologies can be classified as based on subtractive manufacturing, assisted by computer-aided design/computer-aided manufacturing (CAD/CAM) systems, or on additive manufacturing (AM), such as the recently developed laser-based methods. The aim of the study was to assess the surface texture and hardness of metallic structures for dental restorations obtained by alternative technologies: conventional casting (CST), computerized milling (MIL), AM power bed fusion methods, respective selective laser melting (SLM) and selective laser sintering (SLS). For the experimental analyses metallic specimens made of Co-Cr dental alloys were prepared as indicated by the manufacturers. The specimen structure at the macro level was observed by an optical microscope and micro-hardness was measured in all substrates. Metallic frameworks obtained by AM are characterized by increased hardness, depending also on the surface processing. The formation of microstructural defects can be better controlled and avoided during SLM and MIL process. Application of power bed fusion techniques, like SLS and SLM, is currently a challenge in dental alloys processing.
Validation of Reverse-Engineered and Additive-Manufactured Microsurgical Instrument Prototype.
Singh, Ramandeep; Suri, Ashish; Anand, Sneh; Baby, Britty
2016-12-01
With advancements in imaging techniques, neurosurgical procedures are becoming highly precise and minimally invasive, thus demanding development of new ergonomically aesthetic instruments. Conventionally, neurosurgical instruments are manufactured using subtractive manufacturing methods. Such a process is complex, time-consuming, and impractical for prototype development and validation of new designs. Therefore, an alternative design process has been used utilizing blue light scanning, computer-aided designing, and additive manufacturing direct metal laser sintering (DMLS) for microsurgical instrument prototype development. Deviations of DMLS-fabricated instrument were studied by superimposing scan data of fabricated instrument with the computer-aided designing model. Content and concurrent validity of the fabricated prototypes was done by a group of 15 neurosurgeons by performing sciatic nerve anastomosis in small laboratory animals. Comparative scoring was obtained for the control and study instrument. T test was applied to the individual parameters and P values for force (P < .0001) and surface roughness (P < .01) were found to be statistically significant. These 2 parameters were further analyzed using objective measures. Results depicts that additive manufacturing by DMLS provides an effective method for prototype development. However, direct application of these additive-manufactured instruments in the operating room requires further validation. © The Author(s) 2016.
Sun, Yongliang; Xu, Yubin; Li, Cheng; Ma, Lin
2013-11-13
A Kalman/map filtering (KMF)-aided fast normalized cross correlation (FNCC)-based Wi-Fi fingerprinting location sensing system is proposed in this paper. Compared with conventional neighbor selection algorithms that calculate localization results with received signal strength (RSS) mean samples, the proposed FNCC algorithm makes use of all the on-line RSS samples and reference point RSS variations to achieve higher fingerprinting accuracy. The FNCC computes efficiently while maintaining the same accuracy as the basic normalized cross correlation. Additionally, a KMF is also proposed to process fingerprinting localization results. It employs a new map matching algorithm to nonlinearize the linear location prediction process of Kalman filtering (KF) that takes advantage of spatial proximities of consecutive localization results. With a calibration model integrated into an indoor map, the map matching algorithm corrects unreasonable prediction locations of the KF according to the building interior structure. Thus, more accurate prediction locations are obtained. Using these locations, the KMF considerably improves fingerprinting algorithm performance. Experimental results demonstrate that the FNCC algorithm with reduced computational complexity outperforms other neighbor selection algorithms and the KMF effectively improves location sensing accuracy by using indoor map information and spatial proximities of consecutive localization results.
Sun, Yongliang; Xu, Yubin; Li, Cheng; Ma, Lin
2013-01-01
A Kalman/map filtering (KMF)-aided fast normalized cross correlation (FNCC)-based Wi-Fi fingerprinting location sensing system is proposed in this paper. Compared with conventional neighbor selection algorithms that calculate localization results with received signal strength (RSS) mean samples, the proposed FNCC algorithm makes use of all the on-line RSS samples and reference point RSS variations to achieve higher fingerprinting accuracy. The FNCC computes efficiently while maintaining the same accuracy as the basic normalized cross correlation. Additionally, a KMF is also proposed to process fingerprinting localization results. It employs a new map matching algorithm to nonlinearize the linear location prediction process of Kalman filtering (KF) that takes advantage of spatial proximities of consecutive localization results. With a calibration model integrated into an indoor map, the map matching algorithm corrects unreasonable prediction locations of the KF according to the building interior structure. Thus, more accurate prediction locations are obtained. Using these locations, the KMF considerably improves fingerprinting algorithm performance. Experimental results demonstrate that the FNCC algorithm with reduced computational complexity outperforms other neighbor selection algorithms and the KMF effectively improves location sensing accuracy by using indoor map information and spatial proximities of consecutive localization results. PMID:24233027
Computer-based planning of optimal donor sites for autologous osseous grafts
NASA Astrophysics Data System (ADS)
Krol, Zdzislaw; Chlebiej, Michal; Zerfass, Peter; Zeilhofer, Hans-Florian U.; Sader, Robert; Mikolajczak, Pawel; Keeve, Erwin
2002-05-01
Bone graft surgery is often necessary for reconstruction of craniofacial defects after trauma, tumor, infection or congenital malformation. In this operative technique the removed or missing bone segment is filled with a bone graft. The mainstay of the craniofacial reconstruction rests with the replacement of the defected bone by autogeneous bone grafts. To achieve sufficient incorporation of the autograft into the host bone, precise planning and simulation of the surgical intervention is required. The major problem is to determine as accurately as possible the donor site where the graft should be dissected from and to define the shape of the desired transplant. A computer-aided method for semi-automatic selection of optimal donor sites for autografts in craniofacial reconstructive surgery has been developed. The non-automatic step of graft design and constraint setting is followed by a fully automatic procedure to find the best fitting position. In extension to preceding work, a new optimization approach based on the Levenberg-Marquardt method has been implemented and embedded into our computer-based surgical planning system. This new technique enables, once the pre-processing step has been performed, selection of the optimal donor site in time less than one minute. The method has been applied during surgery planning step in more than 20 cases. The postoperative observations have shown that functional results, such as speech and chewing ability as well as restoration of bony continuity were clearly better compared to conventionally planned operations. Moreover, in most cases the duration of the surgical interventions has been distinctly reduced.
Do, An H; Wang, Po T; King, Christine E; Schombs, Andrew; Cramer, Steven C; Nenadic, Zoran
2012-01-01
Gait impairment due to foot drop is a common outcome of stroke, and current physiotherapy provides only limited restoration of gait function. Gait function can also be aided by orthoses, but these devices may be cumbersome and their benefits disappear upon removal. Hence, new neuro-rehabilitative therapies are being sought to generate permanent improvements in motor function beyond those of conventional physiotherapies through positive neural plasticity processes. Here, the authors describe an electroencephalogram (EEG) based brain-computer interface (BCI) controlled functional electrical stimulation (FES) system that enabled a stroke subject with foot drop to re-establish foot dorsiflexion. To this end, a prediction model was generated from EEG data collected as the subject alternated between periods of idling and attempted foot dorsiflexion. This prediction model was then used to classify online EEG data into either "idling" or "dorsiflexion" states, and this information was subsequently used to control an FES device to elicit effective foot dorsiflexion. The performance of the system was assessed in online sessions, where the subject was prompted by a computer to alternate between periods of idling and dorsiflexion. The subject demonstrated purposeful operation of the BCI-FES system, with an average cross-correlation between instructional cues and BCI-FES response of 0.60 over 3 sessions. In addition, analysis of the prediction model indicated that non-classical brain areas were activated in the process, suggesting post-stroke cortical re-organization. In the future, these systems may be explored as a potential therapeutic tool that can help promote positive plasticity and neural repair in chronic stroke patients.
Huang, Zhi; Wang, Xin-zhi; Hou, Yue-Zhong
2015-02-01
Making impressions for maxillectomy patients is an essential but difficult task. This study developed a novel method to fabricate individual trays by computer-aided design (CAD) and rapid prototyping (RP) to simplify the process and enhance patient safety. Five unilateral maxillectomy patients were recruited for this study. For each patient, a computed tomography (CT) scan was taken. Based on the 3D surface reconstruction of the target area, an individual tray was manufactured by CAD/RP. With a conventional custom tray as control, two final impressions were made using the different types of tray for each patient. The trays were sectioned, and in each section the thickness of the material was measured at six evenly distributed points. Descriptive statistics and paired t-test were used to examine the difference of the impression thickness. SAS 9.3 was applied in the statistical analysis. Afterwards, all casts were then optically 3D scanned and compared digitally to evaluate the feasibility of this method. Impressions of all five maxillectomy patients were successfully made with individual trays fabricated by CAD/RP and traditional trays. The descriptive statistics of impression thickness measurement showed slightly more uneven results in the traditional trays, but no statistical significance was shown. A 3D digital comparison showed acceptable discrepancies within 1 mm in the majority of cast areas. The largest difference of 3 mm was observed in the buccal wall of the defective areas. Moderate deviations of 1 to 2 mm were detected in the buccal and labial vestibular groove areas. This study confirmed the feasibility of a novel method of fabricating individual trays by CAD/RP. Impressions made by individual trays manufactured using CAD/RP had a uniform thickness, with an acceptable level of accuracy compared to those made through conventional processes. © 2014 by the American College of Prosthodontists.
Liu, Ding-Yun; Gan, Tao; Rao, Ni-Ni; Xing, Yao-Wen; Zheng, Jie; Li, Sang; Luo, Cheng-Si; Zhou, Zhong-Jun; Wan, Yong-Li
2016-08-01
The gastrointestinal endoscopy in this study refers to conventional gastroscopy and wireless capsule endoscopy (WCE). Both of these techniques produce a large number of images in each diagnosis. The lesion detection done by hand from the images above is time consuming and inaccurate. This study designed a new computer-aided method to detect lesion images. We initially designed an algorithm named joint diagonalisation principal component analysis (JDPCA), in which there are no approximation, iteration or inverting procedures. Thus, JDPCA has a low computational complexity and is suitable for dimension reduction of the gastrointestinal endoscopic images. Then, a novel image feature extraction method was established through combining the algorithm of machine learning based on JDPCA and conventional feature extraction algorithm without learning. Finally, a new computer-aided method is proposed to identify the gastrointestinal endoscopic images containing lesions. The clinical data of gastroscopic images and WCE images containing the lesions of early upper digestive tract cancer and small intestinal bleeding, which consist of 1330 images from 291 patients totally, were used to confirm the validation of the proposed method. The experimental results shows that, for the detection of early oesophageal cancer images, early gastric cancer images and small intestinal bleeding images, the mean values of accuracy of the proposed method were 90.75%, 90.75% and 94.34%, with the standard deviations (SDs) of 0.0426, 0.0334 and 0.0235, respectively. The areas under the curves (AUCs) were 0.9471, 0.9532 and 0.9776, with the SDs of 0.0296, 0.0285 and 0.0172, respectively. Compared with the traditional related methods, our method showed a better performance. It may therefore provide worthwhile guidance for improving the efficiency and accuracy of gastrointestinal disease diagnosis and is a good prospect for clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Cheng, Wan-Lee
This instructional manual contains 12 learning activity packets for use in a workshop in computer-aided design and drafting (CADD). The lessons cover the following topics: introduction to computer graphics and computer-aided design/drafting; coordinate systems; advance space graphics hardware configuration and basic features of the IBM PC…
RASCAL: A Rudimentary Adaptive System for Computer-Aided Learning.
ERIC Educational Resources Information Center
Stewart, John Christopher
Both the background of computer-assisted instruction (CAI) systems in general and the requirements of a computer-aided learning system which would be a reasonable assistant to a teacher are discussed. RASCAL (Rudimentary Adaptive System for Computer-Aided Learning) is a first attempt at defining a CAI system which would individualize the learning…
Theory-of-Mind Development in Oral Deaf Children with Cochlear Implants or Conventional Hearing Aids
ERIC Educational Resources Information Center
Peterson, Candida C.
2004-01-01
Background: In the context of the established finding that theory-of-mind (ToM) growth is seriously delayed in late-signing deaf children, and some evidence of equivalent delays in those learning speech with conventional hearing aids, this study's novel contribution was to explore ToM development in deaf children with cochlear implants. Implants…
NASA Astrophysics Data System (ADS)
Fotin, Sergei V.; Yin, Yin; Haldankar, Hrishikesh; Hoffmeister, Jeffrey W.; Periaswamy, Senthil
2016-03-01
Computer-aided detection (CAD) has been used in screening mammography for many years and is likely to be utilized for digital breast tomosynthesis (DBT). Higher detection performance is desirable as it may have an impact on radiologist's decisions and clinical outcomes. Recently the algorithms based on deep convolutional architectures have been shown to achieve state of the art performance in object classification and detection. Similarly, we trained a deep convolutional neural network directly on patches sampled from two-dimensional mammography and reconstructed DBT volumes and compared its performance to a conventional CAD algorithm that is based on computation and classification of hand-engineered features. The detection performance was evaluated on the independent test set of 344 DBT reconstructions (GE SenoClaire 3D, iterative reconstruction algorithm) containing 328 suspicious and 115 malignant soft tissue densities including masses and architectural distortions. Detection sensitivity was measured on a region of interest (ROI) basis at the rate of five detection marks per volume. Moving from conventional to deep learning approach resulted in increase of ROI sensitivity from 0:832 +/- 0:040 to 0:893 +/- 0:033 for suspicious ROIs; and from 0:852 +/- 0:065 to 0:930 +/- 0:046 for malignant ROIs. These results indicate the high utility of deep feature learning in the analysis of DBT data and high potential of the method for broader medical image analysis tasks.
Evolution of low-profile and lightweight electrical connectors for soldier-worn applications
NASA Astrophysics Data System (ADS)
Gans, Eric; Lee, Kang; Jannson, Tomasz; Walter, Kevin
2011-06-01
In addition to military radios, modern warfighters carry cell phones, GPS devices, computers, and night-vision aids, all of which require electrical cables and connectors for data and power transmission. Currently each electrical device operates via independent cables using conventional cable and connector technology. Conventional cables are stiff and difficult to integrate into a soldier-worn garment. Conventional connectors are tall and heavy, as they were designed to ensure secure connections to bulkhead-type panels, and being tall, represent significant snag-hazards in soldier-worn applications. Physical Optics Corporation has designed a new, lightweight and low-profile electrical connector that is more suitable for body-worn applications and operates much like a standard garment snap. When these connectors are mated, the combined height is <0.3 in. - a significant reduction from the 2.5 in. average height of conventional connectors. Electrical connections can be made with one hand (gloved or bare) and blindly (without looking). Furthermore, POC's connectors are integrated into systems that distribute data or power from a central location on the soldier's vest, reducing the length and weight of the cables necessary to interconnect various mission-critical electronic systems. The result is a lightweight power/data distribution system offering significant advantages over conventional electrical connectors in soldier-worn applications.
NASA's online machine aided indexing system
NASA Technical Reports Server (NTRS)
Silvester, June P.; Genuardi, Michael T.; Klingbiel, Paul H.
1993-01-01
This report describes the NASA Lexical Dictionary, a machine aided indexing system used online at the National Aeronautics and Space Administration's Center for Aerospace Information (CASI). This system is comprised of a text processor that is based on the computational, non-syntactic analysis of input text, and an extensive 'knowledge base' that serves to recognize and translate text-extracted concepts. The structure and function of the various NLD system components are described in detail. Methods used for the development of the knowledge base are discussed. Particular attention is given to a statistically-based text analysis program that provides the knowledge base developer with a list of concept-specific phrases extracted from large textual corpora. Production and quality benefits resulting from the integration of machine aided indexing at CASI are discussed along with a number of secondary applications of NLD-derived systems including on-line spell checking and machine aided lexicography.
Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji
2014-11-01
Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Computer Aided Process Planning for Non-Axisymmetric Deep Drawing Products
NASA Astrophysics Data System (ADS)
Park, Dong Hwan; Yarlagadda, Prasad K. D. V.
2004-06-01
In general, deep drawing products have various cross-section shapes such as cylindrical, rectangular and non-axisymmetric shapes. The application of the surface area calculation to non-axisymmetric deep drawing process has not been published yet. In this research, a surface area calculation for non-axisymmetric deep drawing products with elliptical shape was constructed for a design of blank shape of deep drawing products by using an AutoLISP function of AutoCAD software. A computer-aided process planning (CAPP) system for rotationally symmetric deep drawing products has been developed. However, the application of the system to non-axisymmetric components has not been reported yet. Thus, the CAPP system for non-axisymmetric deep drawing products with elliptical shape was constructed by using process sequence design. The system developed in this work consists of four modules. The first is recognition of shape module to recognize non-axisymmetric products. The second is a three-dimensional (3-D) modeling module to calculate the surface area for non-axisymmetric products. The third is a blank design module to create an oval-shaped blank with the identical surface area. The forth is a process planning module based on the production rules that play the best important role in an expert system for manufacturing. The production rules are generated and upgraded by interviewing field engineers. Especially, the drawing coefficient, the punch and die radii for elliptical shape products are considered as main design parameters. The suitability of this system was verified by applying to a real deep drawing product. This CAPP system constructed would be very useful to reduce lead-time for manufacturing and improve an accuracy of products.
Emulating short-term synaptic dynamics with memristive devices
NASA Astrophysics Data System (ADS)
Berdan, Radu; Vasilaki, Eleni; Khiat, Ali; Indiveri, Giacomo; Serb, Alexandru; Prodromakis, Themistoklis
2016-01-01
Neuromorphic architectures offer great promise for achieving computation capacities beyond conventional Von Neumann machines. The essential elements for achieving this vision are highly scalable synaptic mimics that do not undermine biological fidelity. Here we demonstrate that single solid-state TiO2 memristors can exhibit non-associative plasticity phenomena observed in biological synapses, supported by their metastable memory state transition properties. We show that, contrary to conventional uses of solid-state memory, the existence of rate-limiting volatility is a key feature for capturing short-term synaptic dynamics. We also show how the temporal dynamics of our prototypes can be exploited to implement spatio-temporal computation, demonstrating the memristors full potential for building biophysically realistic neural processing systems.
Bansback, Nick; Li, Linda C; Lynd, Larry; Bryan, Stirling
2014-08-01
Patient decision aids (PtDA) are developed to facilitate informed, value-based decisions about health. Research suggests that even when informed with necessary evidence and information, cognitive errors can prevent patients from choosing the option that is most congruent with their own values. We sought to utilize principles of behavioural economics to develop a computer application that presents information from conventional decision aids in a way that reduces these errors, subsequently promoting higher quality decisions. The Dynamic Computer Interactive Decision Application (DCIDA) was developed to target four common errors that can impede quality decision making with PtDAs: unstable values, order effects, overweighting of rare events, and information overload. Healthy volunteers were recruited to an interview to use three PtDAs converted to the DCIDA on a computer equipped with an eye tracker. Participants were first used a conventional PtDA, and then subsequently used the DCIDA version. User testing was assessed based on whether respondents found the software both usable: evaluated using a) eye-tracking, b) the system usability scale, and c) user verbal responses from a 'think aloud' protocol; and useful: evaluated using a) eye-tracking, b) whether preferences for options were changed, and c) and the decisional conflict scale. Of the 20 participants recruited to the study, 11 were male (55%), the mean age was 35, 18 had at least a high school education (90%), and 8 (40%) had a college or university degree. Eye-tracking results, alongside a mean system usability scale score of 73 (range 68-85), indicated a reasonable degree of usability for the DCIDA. The think aloud study suggested areas for further improvement. The DCIDA also appeared to be useful to participants wherein subjects focused more on the features of the decision that were most important to them (21% increase in time spent focusing on the most important feature). Seven subjects (25%) changed their preferred option when using DCIDA. Preliminary results suggest that DCIDA has potential to improve the quality of patient decision-making. Next steps include larger studies to test individual components of DCIDA and feasibility testing with patients making real decisions.
Comparison between a model-based and a conventional pyramid sensor reconstructor.
Korkiakoski, Visa; Vérinaud, Christophe; Le Louarn, Miska; Conan, Rodolphe
2007-08-20
A model of a non-modulated pyramid wavefront sensor (P-WFS) based on Fourier optics has been presented. Linearizations of the model represented as Jacobian matrices are used to improve the P-WFS phase estimates. It has been shown in simulations that a linear approximation of the P-WFS is sufficient in closed-loop adaptive optics. Also a method to compute model-based synthetic P-WFS command matrices is shown, and its performance is compared to the conventional calibration. It was observed that in poor visibility the new calibration is better than the conventional.
Improving Simulated Annealing by Replacing Its Variables with Game-Theoretic Utility Maximizers
NASA Technical Reports Server (NTRS)
Wolpert, David H.; Bandari, Esfandiar; Tumer, Kagan
2001-01-01
The game-theory field of Collective INtelligence (COIN) concerns the design of computer-based players engaged in a non-cooperative game so that as those players pursue their self-interests, a pre-specified global goal for the collective computational system is achieved as a side-effect. Previous implementations of COIN algorithms have outperformed conventional techniques by up to several orders of magnitude, on domains ranging from telecommunications control to optimization in congestion problems. Recent mathematical developments have revealed that these previously developed algorithms were based on only two of the three factors determining performance. Consideration of only the third factor would instead lead to conventional optimization techniques like simulated annealing that have little to do with non-cooperative games. In this paper we present an algorithm based on all three terms at once. This algorithm can be viewed as a way to modify simulated annealing by recasting it as a non-cooperative game, with each variable replaced by a player. This recasting allows us to leverage the intelligent behavior of the individual players to substantially improve the exploration step of the simulated annealing. Experiments are presented demonstrating that this recasting significantly improves simulated annealing for a model of an economic process run over an underlying small-worlds topology. Furthermore, these experiments reveal novel small-worlds phenomena, and highlight the shortcomings of conventional mechanism design in bounded rationality domains.
Computer-Aided Drug Discovery: Molecular Docking of Diminazene Ligands to DNA Minor Groove
ERIC Educational Resources Information Center
Kholod, Yana; Hoag, Erin; Muratore, Katlynn; Kosenkov, Dmytro
2018-01-01
The reported project-based laboratory unit introduces upper-division undergraduate students to the basics of computer-aided drug discovery as a part of a computational chemistry laboratory course. The students learn to perform model binding of organic molecules (ligands) to the DNA minor groove with computer-aided drug discovery (CADD) tools. The…
Gastric obstruction secondary to metastatic breast cancer: a case report and literature review.
Hussain, Tasadooq; Elahi, Bilal; McManus, Penelope; Mahapatra, Tapan; Kneeshaw, Peter John
2012-08-07
Gastrointestinal tract soft tissues metastasis is a well-known occurrence with invasive lobular breast cancer subtypes. Gastric involvement is more common, with reports of both diffuse and localized involvements. Usually, a gastric localized involvement presents as wall thickening with an appearance similar to that of a gastrointestinal stromal tumour; rarely does a localized metastatic deposit grow aggressively to present as a large tumour causing obstructive symptoms. Our case highlights one such unusual presentation in a patient presenting with non-specific gastrointestinal symptoms. To the best of our knowledge, there have been no previous reports on a similar presentation occurring from a localized metastasis. A 65-year-old Caucasian woman awaiting an outpatient oral gastroduodenoscopy for symptoms of intermittent vomiting, epigastric pains and weight loss of six weeks' duration presented acutely with symptoms of haematemesis and abdominal distension. An initial contrast-enhanced computed tomography scan showed a grossly dilated stomach with a locally advanced stenosing tumour mass at the pylorus. Our patient had a history of left mastectomy and axillary clearance followed by adjuvant endocrine therapy for an oestrogen receptor- and progesterone receptor-positive, grade 2, invasive lobular breast cancer. The oral gastroduodenoscopy confirmed the computed tomography findings; biopsies of the pyloric mass on immunohistochemistry stains were strongly positive for pancytokeratin and gross cystic disease fluid proteins, consistent with an invasive lobular breast cancer metastasis. She received a palliative gastrojejunal bypass and her adjuvant endocrine treatment was switched over to exemestane. Our case highlights the aggressive behaviour of a localized gastric metastasis that is unusual and unexpected. Gastrointestinal symptomatology can be non-specific and, at times, non-diagnostic on conventional mucosal biopsies. A high index of clinical suspicion in patients with a previous history of invasive lobular breast cancer can aid in an early diagnosis and treatment. A combined treatment approach with chemoendocrine therapies achieves remission and improves patient survival.
[Impact of digital technology on clinical practices: perspectives from surgery].
Zhang, Y; Liu, X J
2016-04-09
Digital medical technologies or computer aided medical procedures, refer to imaging, 3D reconstruction, virtual design, 3D printing, navigation guided surgery and robotic assisted surgery techniques. These techniques are integrated into conventional surgical procedures to create new clinical protocols that are known as "digital surgical techniques". Conventional health care is characterized by subjective experiences, while digital medical technologies bring quantifiable information, transferable data, repeatable methods and predictable outcomes into clinical practices. Being integrated into clinical practice, digital techniques facilitate surgical care by improving outcomes and reducing risks. Digital techniques are becoming increasingly popular in trauma surgery, orthopedics, neurosurgery, plastic and reconstructive surgery, imaging and anatomic sciences. Robotic assisted surgery is also evolving and being applied in general surgery, cardiovascular surgery and orthopedic surgery. Rapid development of digital medical technologies is changing healthcare and clinical practices. It is therefore important for all clinicians to purposefully adapt to these technologies and improve their clinical outcomes.
NASA Technical Reports Server (NTRS)
Kolb, Mark A.
1990-01-01
Viewgraphs on Rubber Airplane: Constraint-based Component-Modeling for Knowledge Representation in Computer Aided Conceptual Design are presented. Topics covered include: computer aided design; object oriented programming; airfoil design; surveillance aircraft; commercial aircraft; aircraft design; and launch vehicles.
Wei, Xuelei; Dong, Fuhui
2011-12-01
To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.
The Impact of Machine Translation and Computer-aided Translation on Translators
NASA Astrophysics Data System (ADS)
Peng, Hao
2018-03-01
Under the context of globalization, communications between countries and cultures are becoming increasingly frequent, which make it imperative to use some techniques to help translate. This paper is to explore the influence of computer-aided translation on translators, which is derived from the field of the computer-aided translation (CAT) and machine translation (MT). Followed by an introduction to the development of machine and computer-aided translation, it then depicts the technologies practicable to translators, which are trying to analyze the demand of designing the computer-aided translation so far in translation practice, and optimize the designation of computer-aided translation techniques, and analyze its operability in translation. The findings underline the advantages and disadvantages of MT and CAT tools, and the serviceability and future development of MT and CAT technologies. Finally, this thesis probes into the impact of these new technologies on translators in hope that more translators and translation researchers can learn to use such tools to improve their productivity.
NASA Astrophysics Data System (ADS)
Aono, Masashi; Gunji, Yukio-Pegio
2004-08-01
How can non-algorithmic/non-deterministic computational syntax be computed? "The hyperincursive system" introduced by Dubois is an anticipatory system embracing the contradiction/uncertainty. Although it may provide a novel viewpoint for the understanding of complex systems, conventional digital computers cannot run faithfully as the hyperincursive computational syntax specifies, in a strict sense. Then is it an imaginary story? In this paper we try to argue that it is not. We show that a model of complex systems "Elementary Conflictable Cellular Automata (ECCA)" proposed by Aono and Gunji is embracing the hyperincursivity and the nonlocality. ECCA is based on locality-only type settings basically as well as other CA models, and/but at the same time, each cell is required to refer to globality-dominant regularity. Due to this contradictory locality-globality loop, the time evolution equation specifies that the system reaches the deadlock/infinite-loop. However, we show that there is a possibility of the resolution of these problems if the computing system has parallel and/but non-distributed property like an amoeboid organism. This paper is an introduction to "the slime mold computing" that is an attempt to cultivate an unconventional notion of computation.
Huettig, Fabian; Prutscher, Andreas; Goldammer, Christoph; Kreutzer, Curt A; Weber, Heiner
2016-01-01
The clinical performance of polymethylmethacrylate (PMMA)-based fixed dental prostheses (FDP) was evaluated in the indication of long-term temporaries. In the current indication of the applied machinable PMMA-based material (Vita CAD-Temp), i.e. temporary crowns and FDPs, 27 patients with compromised dentitions (uncertain dental prognosis or postponement of a removable treatment option) were recruited and 45 FDPs (3 or 4 units, 37 terminal-retained, 8 cantilevered) were inserted. Frameworks were computer-aided design (CAD)/computer-aided manufacturing (CAM)-manufactured after conventional impression taking and labside scanning of stone master casts. A resin-modified hybrid cement material (RelyX Unicem) was used for luting in a conventional protocol. Clinical follow-up was performed biannually. Over an observation time from 2 to 26 months (median 13 months), 11 complications were found in 9 out of 45 PMMA restorations: 4 losses of retention, 5 complete fractures; two of these subsequent to a trepanation for endodontic treatment. Thereby, 3 out of 8 cantilevered FDPs had to be removed within 8 months. Thus, the statistical evaluation included FDPs with abutment at end, only. These standard design FDPs (n = 37) showed a 90.4 % survival rate with a complication-free rate of 88.3 % estimated for an observation time of 16 months. Cantilevered FDPs and reconstructions on abutment teeth with markedly reduced biological prognosis or endodontic intervention yielded a high-failure rate. Terminal-retained FDPs performed clinically well in cases without compromised abutment teeth. PMMA-based material might be used successfully for long-term temporization with 3- to 4-unit FDPs in a standard design over at least one year.
Quantum Photonics Beyond Conventional Computing
2015-07-10
polarisation using a half- wave plate (HWP), the two arms are combined by a polarising beam splitter (PBS). The resulting state is passed through the...phase-matched for Type-I SPDC, creating non -collinear degenerate horizontally polarised photon pairs at 808 nm. After converting one arm to vertical...For the case of non -interacting fermions, the transition probabilities for states under unitary evolution are governed by matrix determinants, which are
Attributes Affecting Computer-Aided Decision Making--A Literature Survey.
ERIC Educational Resources Information Center
Moldafsky, Neil I; Kwon, Ik-Whan
1994-01-01
Reviews current literature about personal, demographic, situational, and cognitive attributes that affect computer-aided decision making. The effectiveness of computer-aided decision making is explored in relation to decision quality, effectiveness, and confidence. Studies of the effects of age, anxiety, cognitive type, attitude, gender, and prior…
User-Centered Computer Aided Language Learning
ERIC Educational Resources Information Center
Zaphiris, Panayiotis, Ed.; Zacharia, Giorgos, Ed.
2006-01-01
In the field of computer aided language learning (CALL), there is a need for emphasizing the importance of the user. "User-Centered Computer Aided Language Learning" presents methodologies, strategies, and design approaches for building interfaces for a user-centered CALL environment, creating a deeper understanding of the opportunities and…
Hearing Impairments. Tech Use Guide: Using Computer Technology.
ERIC Educational Resources Information Center
Council for Exceptional Children, Reston, VA. Center for Special Education Technology.
One of nine brief guides for special educators on using computer technology, this guide focuses on advances in electronic aids, computers, telecommunications, and videodiscs to assist students with hearing impairments. Electronic aids include hearing aids, telephone devices for the deaf, teletypes, closed captioning systems for television, and…
Application of infrared thermography in computer aided diagnosis
NASA Astrophysics Data System (ADS)
Faust, Oliver; Rajendra Acharya, U.; Ng, E. Y. K.; Hong, Tan Jen; Yu, Wenwei
2014-09-01
The invention of thermography, in the 1950s, posed a formidable problem to the research community: What is the relationship between disease and heat radiation captured with Infrared (IR) cameras? The research community responded with a continuous effort to find this crucial relationship. This effort was aided by advances in processing techniques, improved sensitivity and spatial resolution of thermal sensors. However, despite this progress fundamental issues with this imaging modality still remain. The main problem is that the link between disease and heat radiation is complex and in many cases even non-linear. Furthermore, the change in heat radiation as well as the change in radiation pattern, which indicate disease, is minute. On a technical level, this poses high requirements on image capturing and processing. On a more abstract level, these problems lead to inter-observer variability and on an even more abstract level they lead to a lack of trust in this imaging modality. In this review, we adopt the position that these problems can only be solved through a strict application of scientific principles and objective performance assessment. Computing machinery is inherently objective; this helps us to apply scientific principles in a transparent way and to assess the performance results. As a consequence, we aim to promote thermography based Computer-Aided Diagnosis (CAD) systems. Another benefit of CAD systems comes from the fact that the diagnostic accuracy is linked to the capability of the computing machinery and, in general, computers become ever more potent. We predict that a pervasive application of computers and networking technology in medicine will help us to overcome the shortcomings of any single imaging modality and this will pave the way for integrated health care systems which maximize the quality of patient care.
Sieira Gil, R; Roig, A Marí; Obispo, C Arranz; Morla, A; Pagès, C Martí; Perez, J Llopis
2015-01-01
The standard of mandibular reconstruction has increased since the introduction of computer-assisted design (CAD) and rapid prototype modelling (RPM) for surgical planning. Between 2008 and 2013, a prospective pilot study of 20 patients was planned to compare the outcomes of patients treated by mandibular reconstruction who had CAD and RPM-guided operations using a precontoured titanium plate, with the outcomes of patients treated conventionally. We recorded the time taken for reconstruction, total operating time, and whether this type of planning could improve the results of mandibular reconstruction. We found significant differences in the incidence of dental malocclusion (p=0.03) and exposure of the titanium plate (p=0.009). The mean operating time for reconstruction in the preoperative planning group was 135 (37)min compared with 176 (58)min in the conventional group (p=0.04). Preoperative planning using CAD and RPM can increase the accuracy of microvascular mandibular reconstruction and reduce the operating time for reconstruction. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Computer Aided Design in Engineering Education.
ERIC Educational Resources Information Center
Gobin, R.
1986-01-01
Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)
Yoon, Hyung-In; Han, Jung-Suk
2016-02-01
The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Hudson, C. A.
1982-01-01
Advances in factory computerization (computer-aided design and computer-aided manufacturing) are reviewed, including discussions of robotics, human factors engineering, and the sociological impact of automation. (JN)
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-31
Research in the initial grant period focused on computational studies relevant to the selective activation of methane, the prime component of natural gas. Reaction coordinates for methane activation by experimental models were delineated, as well as the bonding and structure of complexes that effect this important reaction. This research, highlighted in the following sections, also provided the impetus for further development, and application of methods for modeling metal-containing catalysts. Sections of the report describe the following: methane activation by multiple-bonded transition metal complexes; computational lanthanide chemistry; and methane activation by non-imido, multiple-bonded ligands.
Titanium removable denture based on a one-metal rehabilitation concept.
Ohkubo, Chikahiro; Sato, Yohei; Nishiyama, Yuichiro; Suzuki, Yasunori
2017-09-26
The use of a single metal for all restorations would be necessary because it protects against metal corrosion caused by the contact of different metals. For this "one-metal rehabilitation" concept, non-alloyed commercially pure (CP) titanium should be used for all restorations. Titanium frameworks have been cast and used for the long term without catastrophic failure, whereas they have been fabricated recently using computer-aided design/computer-aided manufacturing (CAD/CAM). However, the milling process for the frameworks of removable partial dentures (RPDs) is not easy because they have very complicated shapes and consist of many components. Currently, the fabrication of RPD frameworks has been challenged by one-process molding using repeated laser sintering and high-speed milling. Laser welding has also been used typically for repairing and rebuilding titanium frameworks. Although laboratory and clinical problems still remain, the one-metal rehabilitation concept using CP titanium as a bioinert metal can be recommended for all restorations.
Morphology control in polymer blend fibers—a high throughput computing approach
NASA Astrophysics Data System (ADS)
Sesha Sarath Pokuri, Balaji; Ganapathysubramanian, Baskar
2016-08-01
Fibers made from polymer blends have conventionally enjoyed wide use, particularly in textiles. This wide applicability is primarily aided by the ease of manufacturing such fibers. More recently, the ability to tailor the internal morphology of polymer blend fibers by carefully designing processing conditions has enabled such fibers to be used in technologically relevant applications. Some examples include anisotropic insulating properties for heat and anisotropic wicking of moisture, coaxial morphologies for optical applications as well as fibers with high internal surface area for filtration and catalysis applications. However, identifying the appropriate processing conditions from the large space of possibilities using conventional trial-and-error approaches is a tedious and resource-intensive process. Here, we illustrate a high throughput computational approach to rapidly explore and characterize how processing conditions (specifically blend ratio and evaporation rates) affect the internal morphology of polymer blends during solvent based fabrication. We focus on a PS: PMMA system and identify two distinct classes of morphologies formed due to variations in the processing conditions. We subsequently map the processing conditions to the morphology class, thus constructing a ‘phase diagram’ that enables rapid identification of processing parameters for specific morphology class. We finally demonstrate the potential for time dependent processing conditions to get desired features of the morphology. This opens up the possibility of rational stage-wise design of processing pathways for tailored fiber morphology using high throughput computing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martins de Oliveira, Jose Jr.; Germano Martins, Antonio Cesar
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 mum was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.
Lara-Mendes, Sônia T de O; Barbosa, Camila de Freitas M; Santa-Rosa, Caroline C; Machado, Vinícius C
2018-05-01
The aim of this study was to describe a guided endodontic technique that facilitates access to root canals of molars presenting with pulp calcifications. A 61-year-old woman presented to our service with pain in the upper left molar region. The second and third left molars showed signs of apical periodontitis confirmed by the cone-beam computed tomographic (CBCT) scans brought to us by the patient at the initial appointment. Conventional endodontic treatment was discontinued given the difficulty in locating the root canals. Intraoral scanning and the CBCT scans were used to plan the access to the calcified canals by means of implant planning software. Guides were fabricated through rapid prototyping and allowed for the correct orientation of a cylindrical drill used to provide access through the calcifications. Second to that, the root canals were prepared with reciprocating endodontic instruments and rested for 2 weeks with intracanal medication. Subsequently, canals were packed with gutta-percha cones using the hydraulic compression technique. Permanent restorations of the access cavities were performed. By comparing the tomographic images, the authors observed a drastic reduction of the periapical lesions as well as the absence of pain symptoms after 3 months. This condition was maintained at the 1-year follow-up. The guided endodontic technique in maxillary molars was shown to be a fast, safe, and predictable therapy and can be regarded as an excellent option for the location of calcified root canals, avoiding failures in complex cases. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Adjoint Sensitivity Analysis for Scale-Resolving Turbulent Flow Solvers
NASA Astrophysics Data System (ADS)
Blonigan, Patrick; Garai, Anirban; Diosady, Laslo; Murman, Scott
2017-11-01
Adjoint-based sensitivity analysis methods are powerful design tools for engineers who use computational fluid dynamics. In recent years, these engineers have started to use scale-resolving simulations like large-eddy simulations (LES) and direct numerical simulations (DNS), which resolve more scales in complex flows with unsteady separation and jets than the widely-used Reynolds-averaged Navier-Stokes (RANS) methods. However, the conventional adjoint method computes large, unusable sensitivities for scale-resolving simulations, which unlike RANS simulations exhibit the chaotic dynamics inherent in turbulent flows. Sensitivity analysis based on least-squares shadowing (LSS) avoids the issues encountered by conventional adjoint methods, but has a high computational cost even for relatively small simulations. The following talk discusses a more computationally efficient formulation of LSS, ``non-intrusive'' LSS, and its application to turbulent flows simulated with a discontinuous-Galkerin spectral-element-method LES/DNS solver. Results are presented for the minimal flow unit, a turbulent channel flow with a limited streamwise and spanwise domain.
The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills
ERIC Educational Resources Information Center
Kösa, Temel; Karakus, Fatih
2018-01-01
The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…
Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.
ERIC Educational Resources Information Center
Gosman, A. D.; And Others
1979-01-01
Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)
Computer-Presented Organizational/Memory Aids as Instruction for Solving Pico-Fomi Problems.
ERIC Educational Resources Information Center
Steinberg, Esther R.; And Others
1985-01-01
Describes investigation of effectiveness of computer-presented organizational/memory aids (matrix and verbal charts controlled by computer or learner) as instructional technique for solving Pico-Fomi problems, and the acquisition of deductive inference rules when such aids are present. Results indicate chart use control should be adapted to…
Early CT findings of Fournier's gangrene in a healthy male.
Sherman, J; Solliday, M; Paraiso, E; Becker, J; Mydlo, J H
1998-01-01
Early clinical identification of Fournier's gangrene is imperative to avoid delay in the aggressive surgical debridement, antibiotic therapy, and sometimes hyperbaric oxygen treatments. We report on the early computed tomography findings of a non-gas-forming Fournier's gangrene in a healthy male to aid urologists, surgeons, and radiologists in the recognition of this rapidly progressive and often fatal infection.
NASA Astrophysics Data System (ADS)
Yamashita, Yasuo; Arimura, Hidetaka; Yoshiura, Takashi; Tokunaga, Chiaki; Magome, Taiki; Monji, Akira; Noguchi, Tomoyuki; Toyofuku, Fukai; Oki, Masafumi; Nakamura, Yasuhiko; Honda, Hiroshi
2010-03-01
Arterial spin labeling (ASL) is one of promising non-invasive magnetic resonance (MR) imaging techniques for diagnosis of Alzheimer's disease (AD) by measuring cerebral blood flow (CBF). The aim of this study was to develop a computer-aided classification system for AD patients based on CBFs measured by the ASL technique. The average CBFs in cortical regions were determined as functional image features based on the CBF map image, which was non-linearly transformed to a Talairach brain atlas by using a free-form deformation. An artificial neural network (ANN) was trained with the CBF functional features in 10 cortical regions, and was employed for distinguishing patients with AD from control subjects. For evaluation of the method, we applied the proposed method to 20 cases including ten AD patients and ten control subjects, who were scanned a 3.0-Tesla MR unit. As a result, the area under the receiver operating characteristic curve obtained by the proposed method was 0.893 based on a leave-one-out-by-case test in identification of AD cases among 20 cases. The proposed method would be feasible for classification of patients with AD.
Effects of venting on wind noise levels measured at the eardrum.
Chung, King
2013-01-01
Wind noise can be a nuisance to hearing aid users. With the advent of sophisticated feedback reduction algorithms, people with higher degrees of hearing loss are fit with larger vents than previously allowed, and more people with lesser degrees of hearing loss are fit with open hearing aids. The purpose of this study was to examine the effects of venting on wind noise levels in the ear canal for hearing aids with omnidirectional and directional microphones. Two behind-the-ear hearing aids were programmed when they were worn on a Knowles Electronics Manikin for Acoustic Research. The hearing aid worn on the right ear was programmed to the omnidirectional microphone mode and the one on the left to the directional microphone mode. The hearing aids were adjusted to linear amplification with flat frequency response in an anechoic chamber. Gains below 10 dB were used to avoid output limiting of wind noise levels at low input levels. Wind noise samples were recorded at the eardrum location in a wind tunnel at wind velocities ranging from a gentle to a strong breeze. The hearing aids were coupled to #13 tubings (i.e., open vent), or conventional skeleton earmolds with no vent, pressure vents, or 3mm vents. Polar and spectral characteristics of wind noise were analyzed off-line using MatLab programs. Wind noise levels in the ear canals were mostly predicted by vent-induced frequency response changes in the conventional earmold conditions for both omnidirectional and directional hearing aids. The open vent condition, however, yielded the lowest levels, which could not be entirely predicted by the frequency response changes of the hearing aids. This indicated that a wind-related vent effect permitted an additional amount of sound reduction in the ear canal, which could not be explained by known vent effects. For the microphone location, form factor, and gain settings tested, open fit hearing aids yielded lower noise levels at the eardrum location than conventional behind-the-ear hearing aids.
Trellis coding techniques for mobile communications
NASA Technical Reports Server (NTRS)
Divsalar, D.; Simon, M. K.; Jedrey, T.
1988-01-01
A criterion for designing optimum trellis codes to be used over fading channels is given. A technique is shown for reducing certain multiple trellis codes, optimally designed for the fading channel, to conventional (i.e., multiplicity one) trellis codes. The computational cutoff rate R0 is evaluated for MPSK transmitted over fading channels. Examples of trellis codes optimally designed for the Rayleigh fading channel are given and compared with respect to R0. Two types of modulation/demodulation techniques are considered, namely coherent (using pilot tone-aided carrier recovery) and differentially coherent with Doppler frequency correction. Simulation results are given for end-to-end performance of two trellis-coded systems.
Reducing Threshold of Multi Quantum Wells InGaN Laser Diode by Using InGaN/GaN Waveguide
NASA Astrophysics Data System (ADS)
Abdullah, Rafid A.; Ibrahim, Kamarulazizi
2010-07-01
ISE TCAD (Integrated System Engineering Technology Computer Aided Design) software simulation program has been utilized to help study the effect of using InGaN/GaN as a waveguide instead of conventional GaN waveguide for multi quantum wells violet InGaN laser diode (LD). Simulation results indicate that the threshold of the LD has been reduced by using InGaN/GaN waveguide where InGaN/GaN waveguide increases the optical confinement factor which leads to increase the confinement carriers at the active region of the LD.
A general numerical analysis of the superconducting quasiparticle mixer
NASA Technical Reports Server (NTRS)
Hicks, R. G.; Feldman, M. J.; Kerr, A. R.
1985-01-01
For very low noise millimeter-wave receivers, the superconductor-insulator-superconductor (SIS) quasiparticle mixer is now competitive with conventional Schottky mixers. Tucker (1979, 1980) has developed a quantum theory of mixing which has provided a basis for the rapid improvement in SIS mixer performance. The present paper is concerned with a general method of numerical analysis for SIS mixers which allows arbitrary terminating impedances for all the harmonic frequencies. This analysis provides an approach for an examination of the range of validity of the three-frequency results of the quantum mixer theory. The new method has been implemented with the aid of a Fortran computer program.
Multi-terminal pipe routing by Steiner minimal tree and particle swarm optimisation
NASA Astrophysics Data System (ADS)
Liu, Qiang; Wang, Chengen
2012-08-01
Computer-aided design of pipe routing is of fundamental importance for complex equipments' developments. In this article, non-rectilinear branch pipe routing with multiple terminals that can be formulated as a Euclidean Steiner Minimal Tree with Obstacles (ESMTO) problem is studied in the context of an aeroengine-integrated design engineering. Unlike the traditional methods that connect pipe terminals sequentially, this article presents a new branch pipe routing algorithm based on the Steiner tree theory. The article begins with a new algorithm for solving the ESMTO problem by using particle swarm optimisation (PSO), and then extends the method to the surface cases by using geodesics to meet the requirements of routing non-rectilinear pipes on the surfaces of aeroengines. Subsequently, the adaptive region strategy and the basic visibility graph method are adopted to increase the computation efficiency. Numeral computations show that the proposed routing algorithm can find satisfactory routing layouts while running in polynomial time.
NASA Astrophysics Data System (ADS)
Mani-Caplazi, Gabriela; Schulz, Georg; Deyhle, Hans; Hotz, Gerhard; Vach, Werner; Wittwer-Backofen, Ursula; Müller, Bert
2017-09-01
Tooth cementum annulation (TCA) is used by anthropologists to decipher age-at-death and stress periods based on yearly deposited incremental lines (ILs). The destructive aspect of the TCA method, which requires cutting the tooth root in sections to display the ILs, using transmission light microscopy, can be problematic for archeological teeth, and so a non-invasive imaging technique is preferred. The purpose of this study is to evaluate conventional micro computed tomography (μCT) and synchrotron radiation-based X-ray micro computed tomography (SRμCT) as a non-destructive technique to explore the tooth cementum ultrastructure and to display ILs. Seven archeological teeth from the Basel- Spitalfriedhof collection (patients died between 1845 and 1868 in the city hospital) were selected for the μCT experiments. This collection is considered a unique worldwide reference series in the anthropological science community, due to the high level of documented life history data in the medical files and the additionally collected and verified birth history by genealogists. The results demonstrate that the conventional μCT is complementary to the SRμCT allowing to prescreen the teeth using conventional μCT to identify the appropriate specimens and areas for the SRμCT measurements. SRμCT displayed cementum ring structure corresponding to the ILs in the microscope view in archeological teeth in a non-invasive fashion with the potential for more accurate assessments of ILs compared to conventional techniques. The ILs were mainly clearly visible, and it was possible to count them for age-at-death assessment and identify qualitatively irregular ILs which could constitute stress markers.
Improving Simulated Annealing by Recasting it as a Non-Cooperative Game
NASA Technical Reports Server (NTRS)
Wolpert, David; Bandari, Esfandiar; Tumer, Kagan
2001-01-01
The game-theoretic field of COllective INtelligence (COIN) concerns the design of computer-based players engaged in a non-cooperative game so that as those players pursue their self-interests, a pre-specified global goal for the collective computational system is achieved "as a side-effect". Previous implementations of COIN algorithms have outperformed conventional techniques by up to several orders of magnitude, on domains ranging from telecommunications control to optimization in congestion problems. Recent mathematical developments have revealed that these previously developed game-theory-motivated algorithms were based on only two of the three factors determining performance. Consideration of only the third factor would instead lead to conventional optimization techniques like simulated annealing that have little to do with non-cooperative games. In this paper we present an algorithm based on all three terms at once. This algorithm can be viewed as a way to modify simulated annealing by recasting it as a non-cooperative game, with each variable replaced by a player. This recasting allows us to leverage the intelligent behavior of the individual players to substantially improve the exploration step of the simulated annealing. Experiments are presented demonstrating that this recasting improves simulated annealing by several orders of magnitude for spin glass relaxation and bin-packing.
Impact of smoking cessation aids and mass media among recent quitters.
Biener, Lois; Reimer, Rebecca L; Wakefield, Melanie; Szczypka, Glen; Rigotti, Nancy A; Connolly, Gregory
2006-03-01
Although studies have addressed the effectiveness of conventional smoking aids such as quit-smoking programs and pharmaceutical therapy, few studies have assessed their likely impact on cessation at the population level relative to the impact of mass media anti-tobacco advertisements. A random digit dial telephone survey of 6739 Massachusetts residents conducted in 2001-2002 yielded a subsample of 787 individuals who had quit-smoking within the past 2 years. Measures included the types of cessation aids used and perceptions of their helpfulness. Rates of population impact were estimated. Multinomial logistic regression determined the predictors of being helped by conventional aids, by TV advertisements only, or having no help. Analyses conducted in 2004-2005 showed that advertisements were the most frequently mentioned source of help among recent quitters. Older more dependent smokers were most likely to find conventional aids helpful. Younger respondents and those who had remained abstinent for more than 6 months were most likely to report being helped by TV ads. The most helpful ads were those that depicted illness due to smoking or provided inspirational quit tips. Anti-tobacco media campaigns are a vital component of the National Action Plan for Tobacco Cessation. It is essential that such a campaign be implemented, both to support the National Quit Line and to provide assistance to those smokers who find no other form of aid helpful.
Zoufaly, Alexander; Cozzi-Lepri, Alessandro; Reekie, Joanne; Kirk, Ole; Lundgren, Jens; Reiss, Peter; Jevtovic, Djordje; Machala, Ladislav; Zangerle, Robert; Mocroft, Amanda; Van Lunzen, Jan
2014-01-01
The impact of immunosuppression despite virological suppression (immuno-virological discordance, ID) on the risk of developing fatal and non-fatal AIDS/non-AIDS events is unclear and remains to be elucidated. Patients in EuroSIDA starting at least 1 new antiretroviral drug with CD4<350 cells/µl and viral load (VL)>500 copies/mL were followed-up from the first day of VL< = 50 copies/ml until a new fatal/non-fatal non-AIDS/AIDS event. Considered non-AIDS events included non-AIDS malignancies, pancreatitis, severe liver disease with hepatic encephalopathy (>grade 3), cardio- and cerebrovascular events, and end-stage renal disease. Patients were classified over time according to whether current CD4 count was above (non-ID) or below (ID) baseline level. Relative rates (RR) of events were calculated for ID vs. non-ID using adjusted Poisson regression models. 2,913 patients contributed 11,491 person-years for the analysis of non-AIDS. 241 pre-specified non-AIDS events (including 84 deaths) and 89 AIDS events (including 10 deaths) occurred. The RR of developing pre-specified non-AIDS events for ID vs. non-ID was 1.96 (95% CI 1.37-2.81, p<0.001) in unadjusted analysis and 1.43 (0.94-2.17, p = 0.095) after controlling for current CD4 count. ID was not associated with the risk of AIDS events (aRR 0.76, 95% CI 0.41-1.38, p = 0.361). Compared to CD4 responders, patients with immuno-virological discordance may be at increased risk of developing non-AIDS events. Further studies are warranted to establish whether in patients with ID, strategies to directly modify CD4 count response may be needed besides the use of ART.
Computer-aided design development transition for IPAD environment
NASA Technical Reports Server (NTRS)
Owens, H. G.; Mock, W. D.; Mitchell, J. C.
1980-01-01
The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.
CAD/CAE Integration Enhanced by New CAD Services Standard
NASA Technical Reports Server (NTRS)
Claus, Russell W.
2002-01-01
A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.
Investigations in Computer-Aided Instruction and Computer-Aided Controls. Final Report.
ERIC Educational Resources Information Center
Rosenberg, R.C.; And Others
These research projects, designed to delve into certain relationships between humans and computers, are focused on computer-assisted instruction and on man-computer interaction. One study demonstrates that within the limits of formal engineering theory, a computer simulated laboratory (Dynamic Systems Laboratory) can be built in which freshmen…
ERIC Educational Resources Information Center
Sinn, John W.
This instructional manual contains five learning activity packets for use in a workshop on computer numerical control for computer-aided manufacturing. The lessons cover the following topics: introduction to computer-aided manufacturing, understanding the lathe, using the computer, computer numerically controlled part programming, and executing a…
Software and resources for computational medicinal chemistry
Liao, Chenzhong; Sitzmann, Markus; Pugliese, Angelo; Nicklaus, Marc C
2011-01-01
Computer-aided drug design plays a vital role in drug discovery and development and has become an indispensable tool in the pharmaceutical industry. Computational medicinal chemists can take advantage of all kinds of software and resources in the computer-aided drug design field for the purposes of discovering and optimizing biologically active compounds. This article reviews software and other resources related to computer-aided drug design approaches, putting particular emphasis on structure-based drug design, ligand-based drug design, chemical databases and chemoinformatics tools. PMID:21707404
Ronit, Andreas; Haissman, Judith; Kirkegaard-Klitbo, Ditte Marie; Kristensen, Thomas Skårup; Lebech, Anne-Mette; Benfield, Thomas; Gerstoft, Jan; Ullum, Henrik; Køber, Lars; Kjær, Andreas; Kofoed, Klaus; Vestbo, Jørgen; Nordestgaard, Børge; Lundgren, Jens; Nielsen, Susanne Dam
2016-11-26
Modern combination antiretroviral therapy (cART) has improved survival for people living with HIV (PLWHIV). Non-AIDS comorbidities have replaced opportunistic infections as leading causes of mortality and morbidity, and are becoming a key health concern as this population continues to age. The aim of this study is to estimate the prevalence and incidence of non-AIDS comorbidity among PLWHIV in Denmark in the cART era and to determine risk factors contributing to the pathogenesis. The study primarily targets cardiovascular, respiratory, and hepatic non-AIDS comorbidity. The Copenhagen comorbidity in HIV-infection (COCOMO) study is an observational, longitudinal cohort study. The study was initiated in 2015 and recruitment is ongoing with the aim of including 1500 PLWHIV from the Copenhagen area. Follow-up examinations after 2 and 10 years are planned. Uninfected controls are derived from the Copenhagen General Population Study (CGPS), a cohort study including 100,000 uninfected participants from the same geographical region. Physiological and biological measures including blood pressure, ankle-brachial index, electrocardiogram, spirometry, exhaled nitric oxide, transient elastography of the liver, computed tomography (CT) angiography of the heart, unenhanced CT of the chest and upper abdomen, and a number of routine biochemical analysis are uniformly collected in participants from the COCOMO study and the CGPS. Plasma, serum, buffy coat, peripheral blood mononuclear cells (PBMC), urine, and stool samples are collected in a biobank for future studies. Data will be updated through periodical linking to national databases. As life expectancy for PLWHIV improves, it is essential to study long-term impact of HIV and cART. We anticipate that findings from this cohort study will increase knowledge on non-AIDS comorbidity in PLWHIV and identify targets for future interventional trials. Recognizing the demographic, clinical and pathophysiological characteristics of comorbidity in PLWHIV may help inform development of new guidelines and enable us to move forward to a more personalized HIV care. ClinicalTrials.gov: NCT02382822 .
Yang, J; Feng, H L
2018-04-09
With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.
Yu, Q
2018-04-09
Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.
Computer-oriented synthesis of wide-band non-uniform negative resistance amplifiers
NASA Technical Reports Server (NTRS)
Branner, G. R.; Chan, S.-P.
1975-01-01
This paper presents a synthesis procedure which provides design values for broad-band amplifiers using non-uniform negative resistance devices. Employing a weighted least squares optimization scheme, the technique, based on an extension of procedures for uniform negative resistance devices, is capable of providing designs for a variety of matching network topologies. It also provides, for the first time, quantitative results for predicting the effects of parameter element variations on overall amplifier performance. The technique is also unique in that it employs exact partial derivatives for optimization and sensitivity computation. In comparison with conventional procedures, significantly improved broad-band designs are shown to result.
The effect of feature selection methods on computer-aided detection of masses in mammograms
NASA Astrophysics Data System (ADS)
Hupse, Rianne; Karssemeijer, Nico
2010-05-01
In computer-aided diagnosis (CAD) research, feature selection methods are often used to improve generalization performance of classifiers and shorten computation times. In an application that detects malignant masses in mammograms, we investigated the effect of using a selection criterion that is similar to the final performance measure we are optimizing, namely the mean sensitivity of the system in a predefined range of the free-response receiver operating characteristics (FROC). To obtain the generalization performance of the selected feature subsets, a cross validation procedure was performed on a dataset containing 351 abnormal and 7879 normal regions, each region providing a set of 71 mass features. The same number of noise features, not containing any information, were added to investigate the ability of the feature selection algorithms to distinguish between useful and non-useful features. It was found that significantly higher performances were obtained using feature sets selected by the general test statistic Wilks' lambda than using feature sets selected by the more specific FROC measure. Feature selection leads to better performance when compared to a system in which all features were used.
ERIC Educational Resources Information Center
Wilkinson-Riddle, G. J.; Patel, Ashok
1998-01-01
Discusses courseware development, including intelligent tutoring systems, under the Teaching and Learning Technology Programme and the Byzantium project that was designed to define computer-aided learning performance standards suitable for numerate business subjects; examine reasons to use computer-aided learning; and improve access to educational…
Enhancing Engineering Computer-Aided Design Education Using Lectures Recorded on the PC
ERIC Educational Resources Information Center
McGrann, Roy T. R.
2006-01-01
Computer-Aided Engineering (CAE) is a course that is required during the third year in the mechanical engineering curriculum at Binghamton University. The primary objective of the course is to educate students in the procedures of computer-aided engineering design. The solid modeling and analysis program Pro/Engineer[TM] (PTC[R]) is used as the…
VanderBurgh, D; Jamieson, R; Beardy, J; Ritchie, S D; Orkin, A
2014-01-01
Community-based first aid training is the collaborative development of locally relevant emergency response training. The Sachigo Lake Wilderness Emergency Response Education Initiative was developed, delivered, and evaluated through two intensive 5-day first aid courses. Sachigo Lake First Nation is a remote Aboriginal community of 450 people in northern Ontario, Canada, with no local paramedical services. These courses were developed in collaboration with the community, with a goal of building community capacity to respond to medical emergencies. Most first aid training programs rely on standardized curriculum developed for urban and rural contexts with established emergency response systems. Delivering effective community-based first aid training in a remote Aboriginal community required specific adaptations to conventional first aid educational content and pedagogy. Three key lessons emerged during this program that used collaborative principles to adapt conventional first aid concepts and curriculum: (1) standardized approaches may not be relevant nor appropriate; (2) relationships between course participants and the people they help are relevant and important; (3) curriculum must be attentive to existing informal and formal emergency response systems. These lessons may be instructive for the development of other programs in similar settings.
Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter
New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified. All study participants were present for the 1-year examination (n = 20 patients, 41 implants, 32 superstructures), and no complications or failures with any implants or superstructures were revealed. The peri-implant bone loss was less than 1 mm for all implants. Within the limitations of this trial, the prototype device provided placement of dental implants without adverse events.
Lalande, David; Hodd, Jeffrey A; Brousseau, John S; Ramos, Van; Dunham, Daniel; Rueggeberg, Frederick
2017-10-14
Because crowns with open margins are a well-known problem and can lead to complications, it is important to assess the accuracy of margins resulting from the use of a new technique. Currently, data regarding the marginal fit of computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate a complete gold crown (CGC) from a castable acrylate resin polymer block are lacking. The purpose of this in vitro study was to compare marginal discrepancy widths of CGCs fabricated by using either conventional hand waxing or acrylate resin polymer blocks generated by using CAD-CAM technology. A plastic model of a first mandibular molar was prepared by using a 1-mm, rounded chamfer margin on the entire circumference of the tooth. The master die was duplicated 30 times, and 15 wax patterns were fabricated by using a manual waxing technique, and 15 were fabricated by using CAD-CAM technology. All patterns were invested and cast, and resulting CGCs were cemented on their respective die by using resin-modified glass ionomer cement. The specimens were then embedded in acrylic resin and sectioned buccolingually. The buccal and lingual marginal discrepancies of each sectioned portion were measured by using microscopy at ×50 magnification. Data were subjected to repeated measures 2-way ANOVA, by using the Tukey post hoc pairwise comparison test (α=.05). The factor of "technique" had no significant influence on marginal discrepancy measurement (P=.431), but a significant effect of "margin location" (P=.019) was noted. The confounding combination of factors was found to be significantly lower marginal discrepancy dimensions of the lingual margin discrepancy than on the buccal side by using CAD-CAM technology. The marginal discrepancy of CAD-CAM acrylate resin crowns was not significantly different from those made with a conventional manual method; however, lingual margin discrepancies present from CAD-CAM-prepared crowns were significantly less than those measured on the respective buccal surface. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Key Issues in Instructional Computer Graphics.
ERIC Educational Resources Information Center
Wozny, Michael J.
1981-01-01
Addresses key issues facing universities which plan to establish instructional computer graphics facilities, including computer-aided design/computer aided manufacturing systems, role in curriculum, hardware, software, writing instructional software, faculty involvement, operations, and research. Thirty-seven references and two appendices are…
Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal
2016-01-01
Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455
NASA Astrophysics Data System (ADS)
Tang, Li; Kwon, Young H.; Alward, Wallace L. M.; Greenlee, Emily C.; Lee, Kyungmoo; Garvin, Mona K.; Abràmoff, Michael D.
2010-03-01
The shape of the optic nerve head (ONH) is reconstructed automatically using stereo fundus color images by a robust stereo matching algorithm, which is needed for a quantitative estimate of the amount of nerve fiber loss for patients with glaucoma. Compared to natural scene stereo, fundus images are noisy because of the limits on illumination conditions and imperfections of the optics of the eye, posing challenges to conventional stereo matching approaches. In this paper, multi scale pixel feature vectors which are robust to noise are formulated using a combination of both pixel intensity and gradient features in scale space. Feature vectors associated with potential correspondences are compared with a disparity based matching score. The deep structures of the optic disc are reconstructed with a stack of disparity estimates in scale space. Optical coherence tomography (OCT) data was collected at the same time, and depth information from 3D segmentation was registered with the stereo fundus images to provide the ground truth for performance evaluation. In experiments, the proposed algorithm produces estimates for the shape of the ONH that are close to the OCT based shape, and it shows great potential to help computer-aided diagnosis of glaucoma and other related retinal diseases.
Zirconia in dentistry: part 2. Evidence-based clinical breakthrough.
Koutayas, Spiridon Oumvertos; Vagkopoulou, Thaleia; Pelekanos, Stavros; Koidis, Petros; Strub, Jörg Rudolf
2009-01-01
An ideal all-ceramic restoration that conforms well and demonstrates enhanced biocompatibility, strength, fit, and esthetics has always been desirable in clinical dentistry. However, the inherent brittleness, low flexural strength, and fracture toughness of conventional glass and alumina ceramics have been the main obstacles for extensive use. The recent introduction of zirconia-based ceramics as a restorative dental material has generated considerable interest in the dental community, which has been expressed with extensive industrial, clinical, and research activity. Contemporary zirconia powder technology contributes to the fabrication of new biocompatible all-ceramic restorations with improved physical properties for a wide range of promising clinical applications. Especially with the development of computer-aided design (CAD)/computer-aided manufacturing (CAM) systems, high-strength zirconia frameworks can be viable for the fabrication of full and partial coverage crowns, fixed partial dentures, veneers, posts and/or cores, primary double crowns, implant abutments, and implants. Data from laboratory and clinical studies are promising regarding their performance and survival. However, clinical data are considered insufficient and the identified premature complications should guide future research. In addition, different zirconia-based dental auxiliary components (i.e., cutting burs and surgical drills, extra-coronal attachments and orthodontic brackets) can also be technologically feasible. This review aims to present and discuss zirconia manufacturing methods and their potential for successful clinical application in dentistry.
Computer Programming Languages and Expertise Needed by Practicing Engineers.
ERIC Educational Resources Information Center
Doelling, Irvin
1980-01-01
Discussed is the present engineering computer environment of a large aerospace company recognized as a leader in the application and development of computer-aided design and computer-aided manufacturing techniques. A review is given of the exposure spectrum of engineers to the world of computing, the computer languages used, and the career impacts…
Rosenkrantz, Andrew B; Doshi, Ankur M; Ginocchio, Luke A; Aphinyanaphongs, Yindalon
2016-12-01
This study aimed to assess the performance of a text classification machine-learning model in predicting highly cited articles within the recent radiological literature and to identify the model's most influential article features. We downloaded from PubMed the title, abstract, and medical subject heading terms for 10,065 articles published in 25 general radiology journals in 2012 and 2013. Three machine-learning models were applied to predict the top 10% of included articles in terms of the number of citations to the article in 2014 (reflecting the 2-year time window in conventional impact factor calculations). The model having the highest area under the curve was selected to derive a list of article features (words) predicting high citation volume, which was iteratively reduced to identify the smallest possible core feature list maintaining predictive power. Overall themes were qualitatively assigned to the core features. The regularized logistic regression (Bayesian binary regression) model had highest performance, achieving an area under the curve of 0.814 in predicting articles in the top 10% of citation volume. We reduced the initial 14,083 features to 210 features that maintain predictivity. These features corresponded with topics relating to various imaging techniques (eg, diffusion-weighted magnetic resonance imaging, hyperpolarized magnetic resonance imaging, dual-energy computed tomography, computed tomography reconstruction algorithms, tomosynthesis, elastography, and computer-aided diagnosis), particular pathologies (prostate cancer; thyroid nodules; hepatic adenoma, hepatocellular carcinoma, non-alcoholic fatty liver disease), and other topics (radiation dose, electroporation, education, general oncology, gadolinium, statistics). Machine learning can be successfully applied to create specific feature-based models for predicting articles likely to achieve high influence within the radiological literature. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Adebayo, D; Bjarnason, I
2006-03-01
The side effects of conventional non-steroidal anti-inflammatory drugs (NSAIDs) on the stomach is undoubtedly a serious public health problem contributing significantly to the morbidity and mortality of patients receiving these drugs. However, the damage of NSAIDs is not confined to the stomach. Indeed the short term and long term damage of NSAIDs on the small bowel (NSAID enteropathy) is more frequent than NSAID gastropathy. Furthermore, NSAID enteropathy is associated with complications (bleeding and protein loss). While many of these are mild, the serious events (significant bleeding, perforation, obstruction, and sudden death) are frequent as that reported for NSAID gastropathy. The diagnosis of NSAID enteropathy has been greatly aided by the introduction of wireless capsule enteroscopy.
NASA Astrophysics Data System (ADS)
Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.
2017-05-01
Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.
Gómez, Sandra L; Montoya, Yesid; Garcia, Nora L; Virgen, Ana L; Botero, Javier E
2016-09-01
The aim of this study was to compare frictional resistance among conventional, passive and active selfligating brackets using Finite Elements Analysis (FEA). Seventynine (79) slide tests were performed by combining an upper first bicuspid conventional bracket, 0.018" stainless steel wires and 0.010" ligature by means of an INSTRON 3345 load system to obtain average maximum static frictional resistance (MSFR). This value was compared to the FR (frictional resistance) obtained by simulation of a slide of the same combination by FEA following conventional bracket modeling by means of Computer Aided Design (CAD). Once the FEA was validated, bracket CADs were designed (upper right first bicuspid conventional, active and passive selfligating bracket) and bracket properties calculated. MSFR was compared among conventional, active and passive selfligating brackets with different alloys and archwire cross sections such as 0.018", 0.019" x 0.025"and 0.020" x 0.020". Passive selfligating brackets had the lowest MSFR, followed by conventional brackets and active selfligating brackets. In conventional brackets, a 0.018" archwire produced a linear pattern of stress with maximum concentration at the center. Conversely, stress in 0.020 x 0.020" and 0.019 x 0.025" archwires was distributed across the width of the slot. The highest normal forces were 1.53 N for the 0.018" archwire, 4.85 N for the 0.020 x 0.020" archwire and 8.18 N for the 0.019 x 0.025" archwire. Passive selfligating brackets presented less frictional resistance than conventional and active selfligating brackets. Regardless of bracket type, greater contact area between the slot and the archwire and the spring clip increased frictional resistance. Sociedad Argentina de Pediatría.
A Study to Determine the Need for a Standard Limiting the Horsepower of Recreational Boats.
1978-09-01
Acceptance Number of Number Fatal Accidents Non -Fatal Accidents - (Lost control ) 1 93 2 :No attempt to avoid collision) 1 19 72 fAttempted to avoic, not enough...base, and an explanation of the computer SModel designed to aid in organizing and analyzing the data are presented with the results of the analyses. An...Standard 75 S 3.2 Non -Powering Related Accident Sample 76 3.3 Coded Information and Coding Form 77 • - 3.4 Effectiveness Evaluation of the Current
Computer Assisted Instructional Design for Computer-Based Instruction. Final Report. Working Papers.
ERIC Educational Resources Information Center
Russell, Daniel M.; Pirolli, Peter
Recent advances in artificial intelligence and the cognitive sciences have made it possible to develop successful intelligent computer-aided instructional systems for technical and scientific training. In addition, computer-aided design (CAD) environments that support the rapid development of such computer-based instruction have also been recently…
A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.
Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus
2016-11-01
Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.
Software For Computer-Aided Design Of Control Systems
NASA Technical Reports Server (NTRS)
Wette, Matthew
1994-01-01
Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.
NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering |
lithium-ion (Li-ion) batteries, known as a multi-scale multi-domain (GH-MSMD) model framework, was News | NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering March 16, 2016 NREL researcher looks across
Defense Acquisitions Acronyms and Terms
2012-12-01
Computer-Aided Design CADD Computer-Aided Design and Drafting CAE Component Acquisition Executive; Computer-Aided Engineering CAIV Cost As an...Radiation to Ordnance HFE Human Factors Engineering HHA Health Hazard Assessment HNA Host-Nation Approval HNS Host-Nation Support HOL High -Order...Engineering Change Proposal VHSIC Very High Speed Integrated Circuit VLSI Very Large Scale Integration VOC Volatile Organic Compound W WAN Wide
[The automatic iris map overlap technology in computer-aided iridiagnosis].
He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan
2002-11-01
In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.
New Paradigms for Computer Aids to Invention.
ERIC Educational Resources Information Center
Langston, M. Diane
Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…
Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis
NASA Astrophysics Data System (ADS)
Nan, Song
2018-03-01
Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.
Three-Dimensional Computational Fluid Dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haworth, D.C.; O'Rourke, P.J.; Ranganathan, R.
1998-09-01
Computational fluid dynamics (CFD) is one discipline falling under the broad heading of computer-aided engineering (CAE). CAE, together with computer-aided design (CAD) and computer-aided manufacturing (CAM), comprise a mathematical-based approach to engineering product and process design, analysis and fabrication. In this overview of CFD for the design engineer, our purposes are three-fold: (1) to define the scope of CFD and motivate its utility for engineering, (2) to provide a basic technical foundation for CFD, and (3) to convey how CFD is incorporated into engineering product and process design.
Feng, Zhi-hong; Dong, Yan; Bai, Shi-zhu; Wu, Guo-feng; Bi, Yun-peng; Wang, Bo; Zhao, Yi-min
2010-01-01
The aim of this article was to demonstrate a novel approach to designing facial prostheses using the transplantation concept and computer-assisted technology for extensive, large, maxillofacial defects that cross the facial midline. The three-dimensional (3D) facial surface images of a patient and his relative were reconstructed using data obtained through optical scanning. Based on these images, the corresponding portion of the relative's face was transplanted to the patient's where the defect was located, which could not be rehabilitated using mirror projection, to design the virtual facial prosthesis without the eye. A 3D model of an artificial eye that mimicked the patient's remaining one was developed, transplanted, and fit onto the virtual prosthesis. A personalized retention structure for the artificial eye was designed on the virtual facial prosthesis. The wax prosthesis was manufactured through rapid prototyping, and the definitive silicone prosthesis was completed. The size, shape, and cosmetic appearance of the prosthesis were satisfactory and matched the defect area well. The patient's facial appearance was recovered perfectly with the prosthesis, as determined through clinical evaluation. The optical 3D imaging and computer-aided design/computer-assisted manufacturing system used in this study can design and fabricate facial prostheses more precisely than conventional manual sculpturing techniques. The discomfort generally associated with such conventional methods was decreased greatly. The virtual transplantation used to design the facial prosthesis for the maxillofacial defect, which crossed the facial midline, and the development of the retention structure for the eye were both feasible.
2018-05-18
AIDS-Related Burkitt Lymphoma; AIDS-Related Diffuse Large B-cell Lymphoma; AIDS-Related Plasmablastic Lymphoma; AIDS-Related Primary Effusion Lymphoma; HIV Infection; AIDS Related Non-Hodgkin Lymphoma
The utility of ERTS-1 data for applications in land use classification. [Texas Gulf Coast
NASA Technical Reports Server (NTRS)
Dornbach, J. E.; Mckain, G. E.
1974-01-01
A comprehensive study has been undertaken to determine the extent to which conventional image interpretation and computer-aided (spectral pattern recognition) analysis techniques using ERTS-1 data could be used to detect, identify (classify), locate, and measure current land use over large geographic areas. It can be concluded that most of the level 1 and 2 categories in the USGS Circular no. 671 can be detected in the Houston-Gulf Coast area using a combination of both techniques for analysis. These capabilities could be exercised over larger geographic areas, however, certain factors such as different vegetative cover, topography, etc. may have to be considered in other geographic regions. The best results in identification (classification), location, and measurement of level 1 and 2 type categories appear to be obtainable through automatic data processing of multispectral scanner computer compatible tapes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... will provide you with appropriate aids such as readers or print magnifiers. The Department will make copies of the notice available, upon request, in large print and as an electronic file on computer disk.... v. Sec'y of Labor, 713 F.3d 1080 (11th Cir. 2013) (holding that the Department of Labor lacks...
ERIC Educational Resources Information Center
Insolia, Gerard
This document contains course outlines in computer-aided manufacturing developed for a business-industry technology resource center for firms in eastern Pennsylvania by Northampton Community College. The four units of the course cover the following: (1) introduction to computer-assisted design (CAD)/computer-assisted manufacturing (CAM); (2) CAM…
ERIC Educational Resources Information Center
Meloy, Jim; And Others
1990-01-01
The relationship between computer-aided design (CAD), computer-aided manufacturing (CAM), and computer numerical control (CNC) computer applications is described. Tips for helping educate the CAM buyer on what to look for and what to avoid when searching for the most appropriate instructional CAM package are provided. (KR)
Zhang, Lei; Shen, Shunyao; Yu, Hongbo; Shen, Steve Guofang; Wang, Xudong
2015-07-01
The aim of this study was to investigate the use of computer-aided design and computer-aided manufacturing hydroxyapatite (HA)/epoxide acrylate maleic (EAM) compound construction artificial implants for craniomaxillofacial bone defects. Computed tomography, computer-aided design/computer-aided manufacturing and three-dimensional reconstruction, as well as rapid prototyping were performed in 12 patients between 2008 and 2013. The customized HA/EAM compound artificial implants were manufactured through selective laser sintering using a rapid prototyping machine into the exact geometric shapes of the defect. The HA/EAM compound artificial implants were then implanted during surgical reconstruction. Color-coded superimpositions demonstrated the discrepancy between the virtual plan and achieved results using Geomagic Studio. As a result, the HA/EAM compound artificial bone implants were perfectly matched with the facial areas that needed reconstruction. The postoperative aesthetic and functional results were satisfactory. The color-coded superimpositions demonstrated good consistency between the virtual plan and achieved results. The three-dimensional maximum deviation is 2.12 ± 0.65 mm and the three-dimensional mean deviation is 0.27 ± 0.07 mm. No facial nerve weakness or pain was observed at the follow-up examinations. Only 1 implant had to be removed 2 months after the surgery owing to severe local infection. No other complication was noted during the follow-up period. In conclusion, computer-aided, individually fabricated HA/EAM compound construction artificial implant was a good craniomaxillofacial surgical technique that yielded improved aesthetic results and functional recovery after reconstruction.
NASA Astrophysics Data System (ADS)
Pereira, Manuel S.; Ambrosio, Jorge A. C.
1993-07-01
During the last few years, major scientific progress has been achieved in fields related to computer aided analysis of multibody systems. In view of this progress and recent developments of computer hardware and general purpose software, there is a need to access the current state of art and results from different schools of thought, with the objective of focussing trends in future research. Going back to 1983 when an important NATO-NSF-ARO Advanced Study Institute on Computer Aided Analysis and Optimization of Mechanical Systems was held at the University of Iowa, one may notice that less then 10 years ago the state of art was mainly dwelling on rigid body dynamics. The interest in the dynamic simulation of mechanical systems has steadily increased in recent years coming mainly from the aerospace and automative industries. The development of multibody system analysis formulations have been more recently motivated with the need to include several features such as: real-time simulation capabilities, highly non-linear control devices, work space path planing, active control of machine flexibilities and reliability and accuracy in the analysis results. The need for accurate and efficient analysis tools for design of large and lightweight mechanical systems has driven many research groups in the challenging problem of flexible systems with an increasing interaction with finite element methodologies. Basic approaches to mechanical systems dynamic analysis have recently been presented in several new text books. These publications demonstrate that both recursive and absolute methods still have their proponents to resolve the redundancy encountered in most mechanical systems.
A Review of Developments in Computer-Based Systems to Image Teeth and Produce Dental Restorations
Rekow, E. Dianne; Erdman, Arthur G.; Speidel, T. Michael
1987-01-01
Computer-aided design and manufacturing (CAD/CAM) make it possible to automate the creation of dental restorations. Currently practiced techniques are described. Three automated systems currently under development are described and compared. Advances in computer-aided design and computer-aided manufacturing (CAD/CAM) provide a new option for dentistry, creating an alternative technique for producing dental restorations. It is possible to create dental restorations that are automatically produced and meet or exceed current requirements for fit and occlusion.
Photogrammetry and computer-aided piping design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keneflick, J.F.; Chirillo, R.D.
1985-02-18
Three-dimensional measurements taken from photographs of a plant model can be digitized and linked with computer-aided piping design. This can short-cut the design and construction of new plants and expedite repair and retrofitting projects. Some designers bridge the gap between model and computer by digitizing from orthographic prints obtained via orthography or the laser scanning of model sections. Such valve or fitting then processed is described in this paper. The marriage of photogrammetry and computer-aided piping design can economically produce such numerical drawings.
Integration of the Execution Support System for the Computer-Aided Prototyping System (CAPS)
1990-09-01
SUPPORT SYSTEM FOR THE COMPUTER -AIDED PROTOTYPING SYSTEM (CAPS) by Frank V. Palazzo September 1990 Thesis Advisor: Luq± Approved for public release...ZATON REPOR ,,.VBE (, 6a NAME OF PERPORMING ORGAN ZAT7ON 6b OFF:CE SYVBOL 7a NAME OF MONITORINC O0-CA’Za- ON Computer Science Department (if applicable...Include Security Classification) Integration of the Execution Support System for the Computer -Aided Prototyping System (C S) 12 PERSONAL AUTHOR(S) Frank V
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, Joshua J.; Taplin, Stephen H.; Carney, Patricia A.; Abraham, Linn; Sickles, Edward A.; D'Orsi, Carl; Berns, Eric A.; Cutter, Gary; Hendrick, R. Edward; Barlow, William E.; Elmore, Joann G.
2011-01-01
Background Computer-aided detection identifies suspicious findings on mammograms to assist radiologists. Since the Food and Drug Administration approved the technology in 1998, it has been disseminated into practice, but its effect on the accuracy of interpretation is unclear. Methods We determined the association between the use of computer-aided detection at mammography facilities and the performance of screening mammography from 1998 through 2002 at 43 facilities in three states. We had complete data for 222,135 women (a total of 429,345 mammograms), including 2351 women who received a diagnosis of breast cancer within 1 year after screening. We calculated the specificity, sensitivity, and positive predictive value of screening mammography with and without computer-aided detection, as well as the rates of biopsy and breast-cancer detection and the overall accuracy, measured as the area under the receiver-operating-characteristic (ROC) curve. Results Seven facilities (16%) implemented computer-aided detection during the study period. Diagnostic specificity decreased from 90.2% before implementation to 87.2% after implementation (P<0.001), the positive predictive value decreased from 4.1% to 3.2% (P = 0.01), and the rate of biopsy increased by 19.7% (P<0.001). The increase in sensitivity from 80.4% before implementation of computer-aided detection to 84.0% after implementation was not significant (P = 0.32). The change in the cancer-detection rate (including invasive breast cancers and ductal carcinomas in situ) was not significant (4.15 cases per 1000 screening mammograms before implementation and 4.20 cases after implementation, P = 0.90). Analyses of data from all 43 facilities showed that the use of computer-aided detection was associated with significantly lower overall accuracy than was nonuse (area under the ROC curve, 0.871 vs. 0.919; P = 0.005). Conclusions The use of computer-aided detection is associated with reduced accuracy of interpretation of screening mammograms. The increased rate of biopsy with the use of computer-aided detection is not clearly associated with improved detection of invasive breast cancer. PMID:17409321
Challenges & Roadmap for Beyond CMOS Computing Simulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodrigues, Arun F.; Frank, Michael P.
Simulating HPC systems is a difficult task and the emergence of “Beyond CMOS” architectures and execution models will increase that difficulty. This document presents a “tutorial” on some of the simulation challenges faced by conventional and non-conventional architectures (Section 1) and goals and requirements for simulating Beyond CMOS systems (Section 2). These provide background for proposed short- and long-term roadmaps for simulation efforts at Sandia (Sections 3 and 4). Additionally, a brief explanation of a proof-of-concept integration of a Beyond CMOS architectural simulator is presented (Section 2.3).
Beyond the political model of reporting: nonspecific symptoms in media communication about AIDS.
Check, W A
1987-01-01
Mass media have functioned well in transmitting much of the basic information about the AIDS epidemic; however, media coverage of AIDS has been flawed. In many ways these flaws have resulted from the limitations and conventions of traditional journalism, especially the need to appeal to a large mainstream audience and a reliance on authorities as sources and validators of information. News stories typically rely on a single articulate authority, and articles that involve conspiracy or controversy or have a high entertainment value are favored. Although coverage of politics and social issues is not distorted by these journalistic conventions, coverage of science suffers. Analysis of news coverage of AIDS shows that mass media often respond to sensationalism rather than to important scientific developments. In addition, scientific disagreements are better adjudicated by evidence than by appeals to authority. As a result, media coverage often obscures the process of scientific deliberation. Public health officials need to consider setting up a special channel of communications to clarify information about AIDS.
Computer-aided Instructional System for Transmission Line Simulation.
ERIC Educational Resources Information Center
Reinhard, Erwin A.; Roth, Charles H., Jr.
A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…
Proceedings of the Workshop on Computational Aspects in the Control of Flexible Systems, part 1
NASA Technical Reports Server (NTRS)
Taylor, Lawrence W., Jr. (Compiler)
1989-01-01
Control/Structures Integration program software needs, computer aided control engineering for flexible spacecraft, computer aided design, computational efficiency and capability, modeling and parameter estimation, and control synthesis and optimization software for flexible structures and robots are among the topics discussed.
Computer aided field editing in the DHS context: the Turkey experiment.
Cushing, J; Loaiza, E
1994-01-01
"In this study two types of field editing used during the Turkey Demographic and Health Survey are compared. These two types of editing are computer aided field editing and manual editing. It is known that manual editing by field editors is a tedious job in which errors especially on skip questions can be missed; however, with the aid of computers field editors could quickly find all occasions on which an interviewer incorrectly followed a skip instruction. At the end of the experiment it has been found...that the field editing done with the aid of a notebook computer was consistently better than that done in the standard manual manner." (SUMMARY IN TUR) excerpt
A Discriminative Approach to EEG Seizure Detection
Johnson, Ashley N.; Sow, Daby; Biem, Alain
2011-01-01
Seizures are abnormal sudden discharges in the brain with signatures represented in electroencephalograms (EEG). The efficacy of the application of speech processing techniques to discriminate between seizure and non-seizure states in EEGs is reported. The approach accounts for the challenges of unbalanced datasets (seizure and non-seizure), while also showing a system capable of real-time seizure detection. The Minimum Classification Error (MCE) algorithm, which is a discriminative learning algorithm with wide-use in speech processing, is applied and compared with conventional classification techniques that have already been applied to the discrimination between seizure and non-seizure states in the literature. The system is evaluated on 22 pediatric patients multi-channel EEG recordings. Experimental results show that the application of speech processing techniques and MCE compare favorably with conventional classification techniques in terms of classification performance, while requiring less computational overhead. The results strongly suggests the possibility of deploying the designed system at the bedside. PMID:22195192
Kitayama, Shuzo; Pilecki, Peter; Nasser, Nasser A; Bravis, Theodora; Wilson, Ron F; Nikaido, Toru; Tagami, Junji; Watson, Timothy F; Foxton, Richard M
2009-08-01
This study investigated the effect of resin coating and occlusal loading on adhesion and microleakage of all-ceramic crowns. Molars were prepared for an all-ceramic crown and were divided into two groups: non-coated (control) and resin-coated with Clearfil Tri-S Bond. Crowns were fabricated using CEREC 3 and cemented using Clearfil Esthetic Cement. After 24 h of storage in water, the restored teeth in each group were divided into two subgroups: unloaded, or loaded while stored in water. Mechanical loading was achieved with an axial force of 80 N at 2.5 cycles s(-1) for 250,000 cycles. After immersion in Rhodamine B, the specimens were sectioned and processed for microleakage evaluation by confocal microscopy, which was followed by further sectioning for microtensile bond testing. Loading had no significant effect on microleakage in either the resin-coated or non-resin-coated groups. Resin coating did not reduce the microleakage at the dentine interface but increased the microleakage at the enamel interface. All the beams fractured during slicing when non-coated and loaded. The bond strengths of non-coated and unloaded, resin-coated and unloaded, and resin-coated and loaded groups were 15.82 +/- 4.22, 15.17 +/- 5.24, and 12.97 +/- 5.82 MPa, respectively. Resin coating with Clearfil Tri-S Bond improved the bonding of resin cement to dentine for loaded specimens. However, it was not effective in reducing the microleakage, regardless of whether it was loaded or unloaded.
Human immunodeficiency virus and acquired immunodeficiency syndrome: correlation but not causation.
Duesberg, P H
1989-01-01
AIDS is an acquired immunodeficiency syndrome defined by a severe depletion of T cells and over 20 conventional degenerative and neoplastic diseases. In the U.S. and Europe, AIDS correlates to 95% with risk factors, such as about 8 years of promiscuous male homosexuality, intravenous drug use, or hemophilia. Since AIDS also correlates with antibody to a retrovirus, confirmed in about 40% of American cases, it has been hypothesized that this virus causes AIDS by killing T cells. Consequently, the virus was termed human immunodeficiency virus (HIV), and antibody to HIV became part of the definition of AIDS. The hypothesis that HIV causes AIDS is examined in terms of Koch's postulates and epidemiological, biochemical, genetic, and evolutionary conditions of viral pathology. HIV does not fulfill Koch's postulates: (i) free virus is not detectable in most cases of AIDS; (ii) virus can only be isolated by reactivating virus in vitro from a few latently infected lymphocytes among millions of uninfected ones; (iii) pure HIV does not cause AIDS upon experimental infection of chimpanzees or accidental infection of healthy humans. Further, HIV violates classical conditions of viral pathology. (i) Epidemiological surveys indicate that the annual incidence of AIDS among antibody-positive persons varies from nearly 0 to over 10%, depending critically on nonviral risk factors. (ii) HIV is expressed in less than or equal to 1 of every 10(4) T cells it supposedly kills in AIDS, whereas about 5% of all T cells are regenerated during the 2 days it takes the virus to infect a cell. (iii) If HIV were the cause of AIDS, it would be the first virus to cause a disease only after the onset of antiviral immunity, as detected by a positive "AIDS test." (iv) AIDS follows the onset of antiviral immunity only after long and unpredictable asymptomatic intervals averaging 8 years, although HIV replicates within 1 to 2 days and induces immunity within 1 to 2 months. (v) HIV supposedly causes AIDS by killing T cells, although retroviruses can only replicate in viable cells. In fact, infected T cells grown in culture continue to divide. (vi) HIV is isogenic with all other retroviruses and does not express a late, AIDS-specific gene. (vii) If HIV were to cause AIDS, it would have a paradoxical, country-specific pathology, causing over 90% Pneumocystis pneumonia and Kaposi sarcoma in the U.S. but over 90% slim disease, fever, and diarrhea in Africa.(viii) It is highly improbable that within the last few years two viruses (HIV-1 and HIV-2) that are only 40% sequence-related would have evolved that could both cause the newly defined syndrome AIDS. Also, viruses are improbable that kill their only natural host with efficiencies of 50-100%, as is claimed for HIVs. It is concluded that HIV is not sufficient for AIDS and that it may not even be necessary for AIDS because its activity is just as low in symptomatic carriers as in asymptomatic carriers. The correlation between antibody to HIV and AIDS does not prove causation, because otherwise indistinguishable diseases are now set apart only on the basis of this antibody. I propose that AIDS is not a contagious syndrome caused by one conventional virus or microbe. No such virus or microbe would require almost a decade to cause primary disease, nor could it cause the diverse collection of AIDS diseases. Neither would its host range be as selective as that of AIDS, nor could it survive if it were as inefficiently transmitted as AIDS. Since AIDS is defined by new combinations of conventional diseases, it may be caused by new combinations of conventional pathogens, including acute viral or microbial infections and chronic drug use and malnutrition. The long and unpredictable intervals between infection with HIV and AIDS would then reflect the thresholds for these pathogenic factors to cause AIDS diseases, instead of an unlikely mechanism of HIV pathogenesis. PMID:2644642
2001-03-01
characteristics shown in Table 1 are based upon a conventional armoured formation, and implicitly at divisional level or above, they could also apply at lower...widely dispersed Ease of Physical big/hot mid-size/cool small/cold targeting Camouflage scrimmed draped visual full/thermal EMCON 4 3 2 1 Visibility...line of sight occulting/obscured non line of sight Contact static FLOT fluid confused melée Armour soft semi-hard hard defensive aids Protection
Quality indexing with computer-aided lexicography
NASA Technical Reports Server (NTRS)
Buchan, Ronald L.
1992-01-01
Indexing with computers is a far cry from indexing with the first indexing tool, the manual card sorter. With the aid of computer-aided lexicography, both indexing and indexing tools can provide standardization, consistency, and accuracy, resulting in greater quality control than ever before. A brief survey of computer activity in indexing is presented with detailed illustrations from NASA activity. Applications from techniques mentioned, such as Retrospective Indexing (RI), can be made to many indexing systems. In addition to improving the quality of indexing with computers, the improved efficiency with which certain tasks can be done is demonstrated.
3D Displays And User Interface Design For A Radiation Therapy Treatment Planning CAD Tool
NASA Astrophysics Data System (ADS)
Mosher, Charles E.; Sherouse, George W.; Chaney, Edward L.; Rosenman, Julian G.
1988-06-01
The long term goal of the project described in this paper is to improve local tumor control through the use of computer-aided treatment design methods that can result in selection of better treatment plans compared with conventional planning methods. To this end, a CAD tool for the design of radiation treatment beams is described. Crucial to the effectiveness of this tool are high quality 3D display techniques. We have found that 2D and 3D display methods dramatically improve the comprehension of the complex spatial relationships between patient anatomy, radiation beams, and dose distributions. In order to take full advantage of these displays, an intuitive and highly interactive user interface was created. If the system is to be used by physicians unfamiliar with computer systems, it is essential that a user interface is incorporated that allows the user to navigate through each step of the design process in a manner similar to what they are used to. Compared with conventional systems, we believe our display and CAD tools will allow the radiotherapist to achieve more accurate beam targetting leading to a better radiation dose configuration to the tumor volume. This would result in a reduction of the dose to normal tissue.
COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS
The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...
Statistical image reconstruction from correlated data with applications to PET
Alessio, Adam; Sauer, Ken; Kinahan, Paul
2008-01-01
Most statistical reconstruction methods for emission tomography are designed for data modeled as conditionally independent Poisson variates. In reality, due to scanner detectors, electronics and data processing, correlations are introduced into the data resulting in dependent variates. In general, these correlations are ignored because they are difficult to measure and lead to computationally challenging statistical reconstruction algorithms. This work addresses the second concern, seeking to simplify the reconstruction of correlated data and provide a more precise image estimate than the conventional independent methods. In general, correlated variates have a large non-diagonal covariance matrix that is computationally challenging to use as a weighting term in a reconstruction algorithm. This work proposes two methods to simplify the use of a non-diagonal covariance matrix as the weighting term by (a) limiting the number of dimensions in which the correlations are modeled and (b) adopting flexible, yet computationally tractable, models for correlation structure. We apply and test these methods with simple simulated PET data and data processed with the Fourier rebinning algorithm which include the one-dimensional correlations in the axial direction and the two-dimensional correlations in the transaxial directions. The methods are incorporated into a penalized weighted least-squares 2D reconstruction and compared with a conventional maximum a posteriori approach. PMID:17921576
Mamdani Fuzzy System for Indoor Autonomous Mobile Robot
NASA Astrophysics Data System (ADS)
Khan, M. K. A. Ahamed; Rashid, Razif; Elamvazuthi, I.
2011-06-01
Several control algorithms for autonomous mobile robot navigation have been proposed in the literature. Recently, the employment of non-analytical methods of computing such as fuzzy logic, evolutionary computation, and neural networks has demonstrated the utility and potential of these paradigms for intelligent control of mobile robot navigation. In this paper, Mamdani fuzzy system for an autonomous mobile robot is developed. The paper begins with the discussion on the conventional controller and then followed by the description of fuzzy logic controller in detail.
Linssen, Anouk M; Joore, Manuela A; Minten, Rianne K H; van Leeuwen, Yvonne D; Anteunis, Lucien J C
2013-10-01
Up to a quarter of the adults who own hearing aids never use them. To provide these 'non-users' with the best help, hearing care professionals need to have an in-depth understanding of the non-users' beliefs and feelings with regard to the non-use. This qualitative study explored these beliefs and feelings in order to increase our understanding of hearing aid non-users. Individual face-to-face semi-structured interviews were completed. Eleven hearing aid owners (aged 54-80 years) who reported that they never or hardly ever used their hearing aids. The participants expressed a variety of feelings towards their non-use, including indifference, self-annoyance, frustration, powerlessness, shame, and guilt. Their feelings were related to beliefs about: (1) the severity of their hearing handicap with and without hearing aids, (2) whom or what was responsible for the non-use, and (3) the attitudes of significant others towards the non-use. Hearing-aid non-users differ in their beliefs and feelings towards the non-use. A patient-centred approach is needed.
Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.
Liedlgruber, Michael; Uhl, Andreas
2011-01-01
Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.
2014-01-01
Background Patient decision aids (PtDA) are developed to facilitate informed, value-based decisions about health. Research suggests that even when informed with necessary evidence and information, cognitive errors can prevent patients from choosing the option that is most congruent with their own values. We sought to utilize principles of behavioural economics to develop a computer application that presents information from conventional decision aids in a way that reduces these errors, subsequently promoting higher quality decisions. Method The Dynamic Computer Interactive Decision Application (DCIDA) was developed to target four common errors that can impede quality decision making with PtDAs: unstable values, order effects, overweighting of rare events, and information overload. Healthy volunteers were recruited to an interview to use three PtDAs converted to the DCIDA on a computer equipped with an eye tracker. Participants were first used a conventional PtDA, and then subsequently used the DCIDA version. User testing was assessed based on whether respondents found the software both usable: evaluated using a) eye-tracking, b) the system usability scale, and c) user verbal responses from a ‘think aloud’ protocol; and useful: evaluated using a) eye-tracking, b) whether preferences for options were changed, and c) and the decisional conflict scale. Results Of the 20 participants recruited to the study, 11 were male (55%), the mean age was 35, 18 had at least a high school education (90%), and 8 (40%) had a college or university degree. Eye-tracking results, alongside a mean system usability scale score of 73 (range 68–85), indicated a reasonable degree of usability for the DCIDA. The think aloud study suggested areas for further improvement. The DCIDA also appeared to be useful to participants wherein subjects focused more on the features of the decision that were most important to them (21% increase in time spent focusing on the most important feature). Seven subjects (25%) changed their preferred option when using DCIDA. Conclusion Preliminary results suggest that DCIDA has potential to improve the quality of patient decision-making. Next steps include larger studies to test individual components of DCIDA and feasibility testing with patients making real decisions. PMID:25084808
Real science at the petascale.
Saksena, Radhika S; Boghosian, Bruce; Fazendeiro, Luis; Kenway, Owain A; Manos, Steven; Mazzeo, Marco D; Sadiq, S Kashif; Suter, James L; Wright, David; Coveney, Peter V
2009-06-28
We describe computational science research that uses petascale resources to achieve scientific results at unprecedented scales and resolution. The applications span a wide range of domains, from investigation of fundamental problems in turbulence through computational materials science research to biomedical applications at the forefront of HIV/AIDS research and cerebrovascular haemodynamics. This work was mainly performed on the US TeraGrid 'petascale' resource, Ranger, at Texas Advanced Computing Center, in the first half of 2008 when it was the largest computing system in the world available for open scientific research. We have sought to use this petascale supercomputer optimally across application domains and scales, exploiting the excellent parallel scaling performance found on up to at least 32 768 cores for certain of our codes in the so-called 'capability computing' category as well as high-throughput intermediate-scale jobs for ensemble simulations in the 32-512 core range. Furthermore, this activity provides evidence that conventional parallel programming with MPI should be successful at the petascale in the short to medium term. We also report on the parallel performance of some of our codes on up to 65 636 cores on the IBM Blue Gene/P system at the Argonne Leadership Computing Facility, which has recently been named the fastest supercomputer in the world for open science.
Computer-assisted photogrammetric mapping systems for geologic studies-A progress report
Pillmore, C.L.; Dueholm, K.S.; Jepsen, H.S.; Schuch, C.H.
1981-01-01
Photogrammetry has played an important role in geologic mapping for many years; however, only recently have attempts been made to automate mapping functions for geology. Computer-assisted photogrammetric mapping systems for geologic studies have been developed and are currently in use in offices of the Geological Survey of Greenland at Copenhagen, Denmark, and the U.S. Geological Survey at Denver, Colorado. Though differing somewhat, the systems are similar in that they integrate Kern PG-2 photogrammetric plotting instruments and small desk-top computers that are programmed to perform special geologic functions and operate flat-bed plotters by means of specially designed hardware and software. A z-drive capability, in which stepping motors control the z-motions of the PG-2 plotters, is an integral part of both systems. This feature enables the computer to automatically position the floating mark on computer-calculated, previously defined geologic planes, such as contacts or the base of coal beds, throughout the stereoscopic model in order to improve the mapping capabilities of the instrument and to aid in correlation and tracing of geologic units. The common goal is to enhance the capabilities of the PG-2 plotter and provide a means by which geologists can make conventional geologic maps more efficiently and explore ways to apply computer technology to geologic studies. ?? 1981.
Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun
2013-12-01
Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-02
... Controls for Conventional Arms and Dual-Use Goods and Technologies is a group of 41 like-minded states... specified and packaged as medical products, are not subject to control. ECCN 1C008 (Non-Fluorinated... technology and computer system design have made control of fault tolerance neither warranted nor feasible...
Wind tunnel and numerical data on the ventilation performance of windcatcher with wing wall.
Nejat, Payam; Calautit, John Kaiser; Abd Majid, Muhd Zaimi; Hughes, Ben Richard; Zeynali, Iman; Jomehzadeh, Fatemeh
2016-12-01
The data presented in this article were the basis for the study reported in the research articles entitled "Evaluation of a two-sided windcatcher integrated with wing wall (as a new design) and comparison with a conventional windcatcher" (P. Nejat, J.K. Calautit, M.Z.A. Majid, B.R. Hughes, I. Zeynali, F. Jomehzadeh, 2016) [1] which presents the effect of wing wall on the air flow distribution under using the windcatchers as a natural ventilation equipment. Here, we detail the wind tunnel testing and numerical set-up used for obtaining the data on ventilation rates and indoor airflow distribution inside a test room with a two-sided windcatcher and wing wall. Three models were integrated with wing wall angled at 30°, 45° and 60° and another windcatcher was a conventional two-sided device. The computer-aided design (CAD) three-dimensional geometries which were produced using Solid Edge modeler are also included in the data article.
Mendenhall, Jeffrey; Meiler, Jens
2016-02-01
Dropout is an Artificial Neural Network (ANN) training technique that has been shown to improve ANN performance across canonical machine learning (ML) datasets. Quantitative Structure Activity Relationship (QSAR) datasets used to relate chemical structure to biological activity in Ligand-Based Computer-Aided Drug Discovery pose unique challenges for ML techniques, such as heavily biased dataset composition, and relatively large number of descriptors relative to the number of actives. To test the hypothesis that dropout also improves QSAR ANNs, we conduct a benchmark on nine large QSAR datasets. Use of dropout improved both enrichment false positive rate and log-scaled area under the receiver-operating characteristic curve (logAUC) by 22-46 % over conventional ANN implementations. Optimal dropout rates are found to be a function of the signal-to-noise ratio of the descriptor set, and relatively independent of the dataset. Dropout ANNs with 2D and 3D autocorrelation descriptors outperform conventional ANNs as well as optimized fingerprint similarity search methods.
Mendenhall, Jeffrey; Meiler, Jens
2016-01-01
Dropout is an Artificial Neural Network (ANN) training technique that has been shown to improve ANN performance across canonical machine learning (ML) datasets. Quantitative Structure Activity Relationship (QSAR) datasets used to relate chemical structure to biological activity in Ligand-Based Computer-Aided Drug Discovery (LB-CADD) pose unique challenges for ML techniques, such as heavily biased dataset composition, and relatively large number of descriptors relative to the number of actives. To test the hypothesis that dropout also improves QSAR ANNs, we conduct a benchmark on nine large QSAR datasets. Use of dropout improved both Enrichment false positive rate (FPR) and log-scaled area under the receiver-operating characteristic curve (logAUC) by 22–46% over conventional ANN implementations. Optimal dropout rates are found to be a function of the signal-to-noise ratio of the descriptor set, and relatively independent of the dataset. Dropout ANNs with 2D and 3D autocorrelation descriptors outperform conventional ANNs as well as optimized fingerprint similarity search methods. PMID:26830599
2018-03-30
ARL-TR-8336 ● MAR 2018 US Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational...so designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official endorsement or approval of...Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational Requirements-based Casualty Assessment Model within
Increasing productivity of the McAuto CAD/CAE system by user-specific applications programming
NASA Technical Reports Server (NTRS)
Plotrowski, S. M.; Vu, T. H.
1985-01-01
Significant improvements in the productivity of the McAuto Computer-Aided Design/Computer-Aided Engineering (CAD/CAE) system were achieved by applications programming using the system's own Graphics Interactive Programming language (GRIP) and the interface capabilities with the main computer on which the system resides. The GRIP programs for creating springs, bar charts, finite element model representations and aiding management planning are presented as examples.
Possible Computer Vision Systems and Automated or Computer-Aided Edging and Trimming
Philip A. Araman
1990-01-01
This paper discusses research which is underway to help our industry reduce costs, increase product volume and value recovery, and market more accurately graded and described products. The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or computer controlled processing. This paper...
Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses.
Syrowatka, Ania; Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn
2016-01-26
Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than others. Integration of content control improved quality of decision making (SMD 0.59 vs 0.23 for knowledge; SMD 0.39 vs 0.29 for decisional conflict). In contrast, tailoring reduced quality of decision making (SMD 0.40 vs 0.71 for knowledge; SMD 0.25 vs 0.52 for decisional conflict). Similarly, patient narratives also reduced quality of decision making (SMD 0.43 vs 0.65 for knowledge; SMD 0.17 vs 0.46 for decisional conflict). Results were varied for different types of explicit values clarification, feedback, and social support. Integration of media rich or interactive features into computer-based decision aids can improve quality of preference-sensitive decision making. However, this is an emerging field with limited evidence to guide use. The systematic review and thematic synthesis identified features that have been integrated into available computer-based decision aids, in an effort to facilitate reporting of these features and to promote integration of such features into decision aids. The meta-analyses and associated subgroup analyses provide preliminary evidence to support integration of specific features into future decision aids. Further research can focus on clarifying independent contributions of specific features through experimental designs and refining the designs of features to improve effectiveness.
Computer Skill Acquisition and Retention: The Effects of Computer-Aided Self-Explanation
ERIC Educational Resources Information Center
Chi, Tai-Yin
2016-01-01
This research presents an experimental study to determine to what extent computer skill learners can benefit from generating self-explanation with the aid of different computer-based visualization technologies. Self-explanation was stimulated with dynamic visualization (Screencast), static visualization (Screenshot), or verbal instructions only,…
Computer aided design of extrusion forming tools for complex geometry profiles
NASA Astrophysics Data System (ADS)
Goncalves, Nelson Daniel Ferreira
In the profile extrusion, the experience of the die designer is crucial for obtaining good results. In industry, it is quite usual the need of several experimental trials for a specific extrusion die before a balanced flow distribution is obtained. This experimental based trial-and-error procedure is time and money consuming, but, it works, and most of the profile extrusion companies rely on such method. However, the competition is forcing the industry to look for more effective procedures and the design of profile extrusion dies is not an exception. For this purpose, computer aided design seems to be a good route. Nowadays, the available computational rheology numerical codes allow the simulation of complex fluid flows. This permits the die designer to evaluate and to optimize the flow channel, without the need to have a physical die and to perform real extrusion trials. In this work, a finite volume based numerical code was developed, for the simulation of non-Newtonian (inelastic) fluid and non-isothermal flows using unstructured meshes. The developed code is able to model the forming and cooling stages of profile extrusion, and can be used to aid the design of forming tools used in the production of complex profiles. For the code verification three benchmark problems were tested: flow between parallel plates, flow around a cylinder, and the lid driven cavity flow. The code was employed to design two extrusion dies to produce complex cross section profiles: a medical catheter die and a wood plastic composite profile for decking applications. The last was experimentally validated. Simple extrusion dies used to produced L and T shaped profiles were studied in detail, allowing a better understanding of the effect of the main geometry parameters on the flow distribution. To model the cooling stage a new implicit formulation was devised, which allowed the achievement of better convergence rates and thus the reduction of the computation times. Having in mind the solution of large dimension problems, the code was parallelized using graphics processing units (GPUs). Speedups of ten times could be obtained, drastically decreasing the time required to obtain results.
Saringer, W; Nöbauer-Huhmann, I; Knosp, E
2002-11-01
The authors present a new method for the reconstruction of large or complex-formed cranial bone defects using prefabricated, computer-generated, individual CFRP (carbon fibre reinforced plastics) medical grade implants. CFRP is a composite material containing carbon fibres embedded in an epoxy resin matrix. It is radiolucent, heat-resistant, extremely strong and light (its weight is 20% that of steel), has a modulus of elasticity close to that of bone, and an established biocompatibility. The utilisation of a CAD/CAM (computer aided design/computer aided manufacture) technique based on digitised computed tomography (CT) data, with stereolithographic modelling as intermediate step, enabled the production of individual, prefabricated CFRP medical grade implants with an arithmetical maximum aberration in extension of less than +/-0.25 mm. Between 1995 and February 2002, 29 patients (15 men and 14 women; mean age, 39.9 years; range, 16 to 67 years) underwent cranioplasty with CFRP medical grade implants at the neurosurgical department of the University of Vienna. Twenty-four patients were repaired secondarily (delayed cranioplasty) while 5 were repaired immediately following craniectomy (single stage cranioplasty). All cases were assessed for the accuracy of the intra-operative fit of the implant, restoration of the natural skull contour and aesthetics and adverse symptoms. The intra-operative fit was excellent in 93.1% and good in 6.9% of the implants. In two cases minor adjustments of the bony margin of the defect were required. The operating time for insertion ranged from 16 to 38 minutes, median 21 minutes. Postoperatively, 86.2% of the patients graded the restoration of their natural skull shape and symmetry as excellent while 13.8% termed it good. In one patient a non-space occupying subdural hygroma was found at the follow-up, but required no intervention. Two patients experienced atrophy of the frontal portion of the temporal muscle while one patient had a transient palsy of the frontal branch of the facial nerve. Over the mean follow-up period of 3.3 years (range, 0.08 to 6.8 years), there were no adverse reactions and no plate had to be removed. Individual, prefabricated CFRP medical grade implants may be considered as an alternative to conventionally utilised materials for cranioplasty, in particular in the challenging group of patients with extensive cranial defects or more complex-formed defects of the fronto-orbital or temporo-zygomatic region, guaranteeing short operating times and excellent functional and aesthetic results, which justifies the expense of their production.
Probing non-Hermitian physics with flying atoms
NASA Astrophysics Data System (ADS)
Wen, Jianming; Xiao, Yanhong; Peng, Peng; Cao, Wanxia; Shen, Ce; Qu, Weizhi; Jiang, Liang
2016-05-01
Non-Hermtian optical systems with parity-time (PT) symmetry provide new means for light manipulation and control. To date, most of experimental demonstrations on PT symmetry rely on advanced nanotechnologies and sophisticated fabrication techniques to manmade solid-state materials. Here, we report the first experimental realization of optical anti-PT symmetry, a counterpart of conventional PT symmetry, in a warm atomic-vapor cell. By exploiting rapid coherence transport via flying atoms, we observe essential features of anti-PT symmetry with an unprecedented precision on phase-transition threshold. Moreover, our system allows nonlocal interference of two spatially-separated fields as well as anti-PT assisted four-wave mixing. Besides, another intriguing feature offered by the system is refractionless (or unit-refraction) light propagation. Our results thus represent a significant advance in non-Hermitian physics by bridging a firm connection with the AMO field, where novel phenomena and applications in quantum and nonlinear optics aided by (anti-)PT symmetry can be anticipated.
WINCADRE (COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed ...
Shin, Younghak; Lee, Seungchan; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan; Lee, Heung-No
2015-11-01
One of the main problems related to electroencephalogram (EEG) based brain-computer interface (BCI) systems is the non-stationarity of the underlying EEG signals. This results in the deterioration of the classification performance during experimental sessions. Therefore, adaptive classification techniques are required for EEG based BCI applications. In this paper, we propose simple adaptive sparse representation based classification (SRC) schemes. Supervised and unsupervised dictionary update techniques for new test data and a dictionary modification method by using the incoherence measure of the training data are investigated. The proposed methods are very simple and additional computation for the re-training of the classifier is not needed. The proposed adaptive SRC schemes are evaluated using two BCI experimental datasets. The proposed methods are assessed by comparing classification results with the conventional SRC and other adaptive classification methods. On the basis of the results, we find that the proposed adaptive schemes show relatively improved classification accuracy as compared to conventional methods without requiring additional computation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin
2013-09-01
There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee.
Program Aids In Printing FORTRAN-Coded Output
NASA Technical Reports Server (NTRS)
Akian, Richard A.
1993-01-01
FORPRINT computer program prints FORTRAN-coded output files on most non-Postscript printers with such extra features as control of fonts for Epson and Hewlett Packard printers. Rewrites data to printer and inserts correct printer-control codes. Alternative uses include ability to separate data or ASCII file during printing by use of editing software to insert "1" in first column of data line that starts new page. Written in FORTRAN 77.
Ran, Changyan; Cheng, Xianghong
2016-01-01
This paper presents a direct and non-singular approach based on an unscented Kalman filter (UKF) for the integration of strapdown inertial navigation systems (SINSs) with the aid of velocity. The state vector includes velocity and Euler angles, and the system model contains Euler angle kinematics equations. The measured velocity in the body frame is used as the filter measurement. The quaternion nonlinear equality constraint is eliminated, and the cross-noise problem is overcome. The filter model is simple and easy to apply without linearization. Data fusion is performed by an UKF, which directly estimates and outputs the navigation information. There is no need to process navigation computation and error correction separately because the navigation computation is completed synchronously during the filter time updating. In addition, the singularities are avoided with the help of the dual-Euler method. The performance of the proposed approach is verified by road test data from a land vehicle equipped with an odometer aided SINS, and a singularity turntable test is conducted using three-axis turntable test data. The results show that the proposed approach can achieve higher navigation accuracy than the commonly-used indirect approach, and the singularities can be efficiently removed as the result of dual-Euler method. PMID:27598169
Microhardness evaluations of CAD/CAM ceramics irradiated with CO2 or Nd:YAP laser
Rocca, Jean Paul; Fornaini, Carlo; Medioni, Etienne; Brulat-Bouchard, Nathalie
2017-01-01
Background and aims The aim of this study was to measure the microhardness values of irradiated computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics surfaces before and after thermal treatment. Materials and Methods Sixty CAD/CAM ceramic discs were prepared and grouped by material, i.e. lithium disilicate ceramic (Emax CAD) and zirconia ceramic (Emax ZirCAD). Laser irradiation at the material surface was performed with a carbon dioxide laser at 5 Watt (W) or 10 W power in continuous mode (CW mode), or with a neodymium:yttrium aluminum perovskite (Nd:YAP) laser at 10 W on graphite and non-graphite surfaces. Vickers hardness was tested at 0.3 kgf for lithium disilicate and 1 kgf for zirconia. Results Emax CAD irradiated with CO2 at 5 W increased microhardness by 6.32 GPa whereas Emax ZirCAD irradiated with Nd:YAP decreased microhardness by 17.46 GPa. Conclusion CO2 laser effectively increases the microhardness of lithium disilicate ceramics (Emax CAD). PMID:28740324
Twellmann, Thorsten; Meyer-Baese, Anke; Lange, Oliver; Foo, Simon; Nattkemper, Tim W.
2008-01-01
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important tool in breast cancer diagnosis, but evaluation of multitemporal 3D image data holds new challenges for human observers. To aid the image analysis process, we apply supervised and unsupervised pattern recognition techniques for computing enhanced visualizations of suspicious lesions in breast MRI data. These techniques represent an important component of future sophisticated computer-aided diagnosis (CAD) systems and support the visual exploration of spatial and temporal features of DCE-MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogeneity of cancerous tissue, these techniques reveal signals with malignant, benign and normal kinetics. They also provide a regional subclassification of pathological breast tissue, which is the basis for pseudo-color presentations of the image data. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging. PMID:19255616
Viability of Bioprinted Cellular Constructs Using a Three Dispenser Cartesian Printer.
Dennis, Sarah Grace; Trusk, Thomas; Richards, Dylan; Jia, Jia; Tan, Yu; Mei, Ying; Fann, Stephen; Markwald, Roger; Yost, Michael
2015-09-22
Tissue engineering has centralized its focus on the construction of replacements for non-functional or damaged tissue. The utilization of three-dimensional bioprinting in tissue engineering has generated new methods for the printing of cells and matrix to fabricate biomimetic tissue constructs. The solid freeform fabrication (SFF) method developed for three-dimensional bioprinting uses an additive manufacturing approach by depositing droplets of cells and hydrogels in a layer-by-layer fashion. Bioprinting fabrication is dependent on the specific placement of biological materials into three-dimensional architectures, and the printed constructs should closely mimic the complex organization of cells and extracellular matrices in native tissue. This paper highlights the use of the Palmetto Printer, a Cartesian bioprinter, as well as the process of producing spatially organized, viable constructs while simultaneously allowing control of environmental factors. This methodology utilizes computer-aided design and computer-aided manufacturing to produce these specific and complex geometries. Finally, this approach allows for the reproducible production of fabricated constructs optimized by controllable printing parameters.
Quantitative diagnosis of tongue cancer from histological images in an animal model
NASA Astrophysics Data System (ADS)
Lu, Guolan; Qin, Xulei; Wang, Dongsheng; Muller, Susan; Zhang, Hongzheng; Chen, Amy; Chen, Zhuo G.; Fei, Baowei
2016-03-01
We developed a chemically-induced oral cancer animal model and a computer aided method for tongue cancer diagnosis. The animal model allows us to monitor the progress of the lesions over time. Tongue tissue dissected from mice was sent for histological processing. Representative areas of hematoxylin and eosin stained tissue from tongue sections were captured for classifying tumor and non-tumor tissue. The image set used in this paper consisted of 214 color images (114 tumor and 100 normal tissue samples). A total of 738 color, texture, morphometry and topology features were extracted from the histological images. The combination of image features from epithelium tissue and its constituent nuclei and cytoplasm has been demonstrated to improve the classification results. With ten iteration nested cross validation, the method achieved an average sensitivity of 96.5% and a specificity of 99% for tongue cancer detection. The next step of this research is to apply this approach to human tissue for computer aided diagnosis of tongue cancer.
Signal and noise extraction from analog memory elements for neuromorphic computing.
Gong, N; Idé, T; Kim, S; Boybat, I; Sebastian, A; Narayanan, V; Ando, T
2018-05-29
Dense crossbar arrays of non-volatile memory (NVM) can potentially enable massively parallel and highly energy-efficient neuromorphic computing systems. The key requirements for the NVM elements are continuous (analog-like) conductance tuning capability and switching symmetry with acceptable noise levels. However, most NVM devices show non-linear and asymmetric switching behaviors. Such non-linear behaviors render separation of signal and noise extremely difficult with conventional characterization techniques. In this study, we establish a practical methodology based on Gaussian process regression to address this issue. The methodology is agnostic to switching mechanisms and applicable to various NVM devices. We show tradeoff between switching symmetry and signal-to-noise ratio for HfO 2 -based resistive random access memory. Then, we characterize 1000 phase-change memory devices based on Ge 2 Sb 2 Te 5 and separate total variability into device-to-device variability and inherent randomness from individual devices. These results highlight the usefulness of our methodology to realize ideal NVM devices for neuromorphic computing.
Non-electronic communication aids for people with complex communication needs.
Iacono, Teresa; Lyon, Katie; West, Denise
2011-10-01
Non-electronic communication aids provide one form of augmentative and alternative communication (AAC) for people with complex communication needs. The aim here was to explore non-electronic communication aids as one AAC option and research challenges. This aim was addressed by reviewing funding for the provision of AAC systems, data from an Australian pilot project providing non-electronic communication aids, an audit of aided AAC published studies (2000-2009), and discussion of the review literature. Combined, these sources indicate that although there is great demand for non-electronic communication aids, funding schemes, both in Australia and internationally, have focused on electronic communication aids. Such funding has usually failed to meet the total device costs and has not provided for adequate speech-language pathology support. Data from the pilot indicated the demand for non-electronic communication aids, and patterns suggest potential factors that govern the types selected. Despite the high demand for non-electronic aids, the research literature has tended to focus on electronic communication aids, including within intervention studies and addressing design features and long-term outcomes. Concerns about ensuring that AAC systems are chosen according to the assessed needs of individuals are discussed within the context of limitations in outcomes research and appropriate outcome measures.
NASA Technical Reports Server (NTRS)
Litvin, Faydor L.; Tsay, Chung-Biau
1987-01-01
The authors have proposed a method for the generation of circular arc helical gears which is based on the application of standard equipment, worked out all aspects of the geometry of the gears, proposed methods for the computer aided simulation of conditions of meshing and bearing contact, investigated the influence of manufacturing and assembly errors, and proposed methods for the adjustment of gears to these errors. The results of computer aided solutions are illustrated with computer graphics.
Han, K S; Choi, H J; Jung, D C; Park, S; Cho, K S; Joung, J Y; Seo, H K; Chung, J; Lee, K H
2011-03-01
To evaluate the diagnostic accuracy of conventional cystography for the detection of urine leakage at the vesicourethral anastomosis (VUA) site after radical prostatectomy based on computed tomography (CT) cystography. Patients who underwent radical prostatectomies at a single tertiary cancer centre were prospectively enrolled. Conventional cystography was routinely performed on postoperative day 7. Non-enhanced pelvic CT images were obtained after retrograde instillation of the same contrast material for a reference standard of urine leakage at the VUA site. Urine leakage was classified as follows: none; a plication abnormality; mild; moderate; and excessive. One hundred and twenty consecutive patients were enrolled. Conventional cystography detected 14 urine leakages, but CT cystography detected 40 urine leakages, which consisted of 28 mild and 12 moderate urine leakages. When using CT cystography as the standard measurement, conventional cystography showed a diagnostic accuracy of 17.8% (5/28) for mild urine leakage and 75% (9/12) for moderate leakage. Of nine patients diagnosed with mild leakage on conventional cystography, four (44.4%) had complicated moderate urine leakages based on CT cystography, requiring prolonged catheterization. The sensitivity, specificity, positive and negative predictive values, and accuracy of conventional cystography were 35, 100, 100, 75.4, and 78.3%, respectively. Conventional cystography is less accurate than CT cystography for diagnosing urine leakage at the VUA site after a radical prostatectomy. The present results suggest that CT cystography is a good choice for diagnostic imaging of urine leakage after radical prostatectomy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Computer-aided drug discovery.
Bajorath, Jürgen
2015-01-01
Computational approaches are an integral part of interdisciplinary drug discovery research. Understanding the science behind computational tools, their opportunities, and limitations is essential to make a true impact on drug discovery at different levels. If applied in a scientifically meaningful way, computational methods improve the ability to identify and evaluate potential drug molecules, but there remain weaknesses in the methods that preclude naïve applications. Herein, current trends in computer-aided drug discovery are reviewed, and selected computational areas are discussed. Approaches are highlighted that aid in the identification and optimization of new drug candidates. Emphasis is put on the presentation and discussion of computational concepts and methods, rather than case studies or application examples. As such, this contribution aims to provide an overview of the current methodological spectrum of computational drug discovery for a broad audience.
Computer-aided detection of bladder wall thickening in CT urography (CTU)
NASA Astrophysics Data System (ADS)
Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon Z.; Gordon, Marshall N.; Samala, Ravi K.
2018-02-01
We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). Bladder wall thickening is a manifestation of bladder cancer and its detection is more challenging than the detection of bladder masses. We first segmented the inner and outer bladder walls using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential lesions. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify regions of wall thickening candidates. Volume-based features of the wall thickening candidates were analyzed with linear discriminant analysis (LDA) to differentiate bladder wall thickenings from false positives. A data set of 112 patients, 87 with wall thickening and 25 with normal bladders, was collected retrospectively with IRB approval, and split into independent training and test sets. Of the 57 training cases, 44 had bladder wall thickening and 13 were normal. Of the 55 test cases, 43 had wall thickening and 12 were normal. The LDA classifier was trained with the training set and evaluated with the test set. FROC analysis showed that the system achieved sensitivities of 93.2% and 88.4% for the training and test sets, respectively, at 0.5 FPs/case.
Computer-Aided Engineering Education at the K.U. Leuven.
ERIC Educational Resources Information Center
Snoeys, R.; Gobin, R.
1987-01-01
Describes some recent initiatives and developments in the computer-aided design program in the engineering faculty of the Katholieke Universiteit Leuven (Belgium). Provides a survey of the engineering curriculum, the computer facilities, and the main software packages available. (TW)
Software Tools for Shipbuilding Productivity
1984-12-01
shipbuilding, is that design, manufacturing and robotic technology applications to shipbuilding have been proven. all aspects of shipbuilding is now a task...technical information about the process of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) effectively has been a problem of serious and...Design (CAD) 3.4.1 CAD System Components 3.4.2 CAD System Benefits 3.4.3 New and Future CAD Technologies Computer Aided Manufacturing (CAM) 3.5.1 CAM
Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip
2014-05-01
Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.
Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y
2015-11-01
To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.
Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes
2013-09-01
The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.
Computer Simulated Visual and Tactile Feedback as an Aid to Manipulator and Vehicle Control,
1981-05-08
STATEMENT ........................ 8 Artificial Intellegence Versus Supervisory Control ....... 8 Computer Generation of Operator Feedback...operator. Artificial Intelligence Versus Supervisory Control The use of computers to aid human operators can be divided into two catagories: artificial ...operator. Artificial intelligence ( A. I. ) attempts to give the computer maximum intelligence and to replace all operator functions by the computer
Falster, Kathleen; Choi, Jun Yong; Donovan, Basil; Duncombe, Chris; Mulhall, Brian; Sowden, David; Zhou, Jialun; Law, Matthew G
2009-11-13
Although studies have shown reductions in mortality from AIDS after the introduction of combination antiretroviral treatment (cART), little is known about cause-specific mortality in low-income settings in the cART era. We explored predictors of AIDS and non-AIDS mortality and compared cause-specific mortality across high-income and low-income settings in the Asia-Pacific region. We followed patients in the Asia Pacific HIV Observational Database from the date they started cART (or cohort enrolment if cART initiation was identified retrospectively), until the date of death or last follow-up visit. Competing risks methods were used to estimate the cumulative incidence, and to investigate predictors, of AIDS and non-AIDS mortality. Of 4252 patients, 215 died; 89 from AIDS, 97 from non-AIDS causes and 29 from unknown causes. Age more than 50 years [hazard ratio 4.29; 95% confidence interval (CI) 2.10-8.79] and CD4 cell counts less than or equal to 100 cells/microl (hazard ratio 8.59; 95% CI 5.66-13.03) were associated with an increased risk of non-AIDS mortality. Risk factors for AIDS mortality included CD4 cell counts less than or equal to 100 cells/microl (hazard ratio 34.97; 95% CI 18.01-67.90) and HIV RNA 10 001 or more (hazard ratio 4.21; 95% CI 2.07-8.55). There was some indication of a lower risk of non-AIDS mortality in Asian high-income, and possibly low-income, countries compared to Australia. Immune deficiency is associated with an increased risk of AIDS and non-AIDS mortality. Older age predicts non-AIDS mortality in the cART era. Less conclusive was the association between country-income level and cause-specific mortality because of the relatively high proportion of unknown causes of death in low-income settings.
Virtual Reality versus Computer-Aided Exposure Treatments for Fear of Flying
ERIC Educational Resources Information Center
Tortella-Feliu, Miquel; Botella, Cristina; Llabres, Jordi; Breton-Lopez, Juana Maria; del Amo, Antonio Riera; Banos, Rosa M.; Gelabert, Joan M.
2011-01-01
Evidence is growing that two modalities of computer-based exposure therapies--virtual reality and computer-aided psychotherapy--are effective in treating anxiety disorders, including fear of flying. However, they have not yet been directly compared. The aim of this study was to analyze the efficacy of three computer-based exposure treatments for…
The Implications of Cognitive Psychology for Computer-Based Learning Tools.
ERIC Educational Resources Information Center
Kozma, Robert B.
1987-01-01
Defines cognitive computer tools as software programs that use the control capabilities of computers to amplify, extend, or enhance human cognition; suggests seven ways in which computers can aid learning; and describes the "Learning Tool," a software package for the Apple Macintosh microcomputer that is designed to aid learning of…
Artificial Intelligence and Computer Assisted Instruction. CITE Report No. 4.
ERIC Educational Resources Information Center
Elsom-Cook, Mark
The purpose of the paper is to outline some of the major ways in which artificial intelligence research and techniques can affect usage of computers in an educational environment. The role of artificial intelligence is defined, and the difference between Computer Aided Instruction (CAI) and Intelligent Computer Aided Instruction (ICAI) is…
Electronic Circuit Analysis Language (ECAL)
NASA Astrophysics Data System (ADS)
Chenghang, C.
1983-03-01
The computer aided design technique is an important development in computer applications and it is an important component of computer science. The special language for electronic circuit analysis is the foundation of computer aided design or computer aided circuit analysis (abbreviated as CACD and CACA) of simulated circuits. Electronic circuit analysis language (ECAL) is a comparatively simple and easy to use circuit analysis special language which uses the FORTRAN language to carry out the explanatory executions. It is capable of conducting dc analysis, ac analysis, and transient analysis of a circuit. Futhermore, the results of the dc analysis can be used directly as the initial conditions for the ac and transient analyses.
NASA Astrophysics Data System (ADS)
Alam, Mahtab; Truong, Dennis Q.; Khadka, Niranjan; Bikson, Marom
2016-06-01
Transcranial direct current stimulation (tDCS) is a non-invasive neuromodulation technique that applies low amplitude current via electrodes placed on the scalp. Rather than directly eliciting a neuronal response, tDCS is believed to modulate excitability—enhancing or suppressing neuronal activity in regions of the brain depending on the polarity of stimulation. The specificity of tDCS to any therapeutic application derives in part from how electrode configuration determines the brain regions that are stimulated. Conventional tDCS uses two relatively large pads (>25 cm2) whereas high-definition tDCS (HD-tDCS) uses arrays of smaller electrodes to enhance brain targeting. The 4 × 1 concentric ring HD-tDCS (one center electrode surrounded by four returns) has been explored in application where focal targeting of cortex is desired. Here, we considered optimization of concentric ring HD-tDCS for targeting: the role of electrodes in the ring and the ring’s diameter. Finite element models predicted cortical electric field generated during tDCS. High resolution MRIs were segmented into seven tissue/material masks of varying conductivities. Computer aided design (CAD) model of electrodes, gel, and sponge pads were incorporated into the segmentation. Volume meshes were generated and the Laplace equation (\
Iyatomi, Hitoshi; Oka, Hiroshi; Saito, Masataka; Miyake, Ayako; Kimoto, Masayuki; Yamagami, Jun; Kobayashi, Seiichiro; Tanikawa, Akiko; Hagiwara, Masafumi; Ogawa, Koichi; Argenziano, Giuseppe; Soyer, H Peter; Tanaka, Masaru
2006-04-01
The aims of this study were to provide a quantitative assessment of the tumour area extracted by dermatologists and to evaluate computer-based methods from dermoscopy images for refining a computer-based melanoma diagnostic system. Dermoscopic images of 188 Clark naevi, 56 Reed naevi and 75 melanomas were examined. Five dermatologists manually drew the border of each lesion with a tablet computer. The inter-observer variability was evaluated and the standard tumour area (STA) for each dermoscopy image was defined. Manual extractions by 10 non-medical individuals and by two computer-based methods were evaluated with STA-based assessment criteria: precision and recall. Our new computer-based method introduced the region-growing approach in order to yield results close to those obtained by dermatologists. The effectiveness of our extraction method with regard to diagnostic accuracy was evaluated. Two linear classifiers were built using the results of conventional and new computer-based tumour area extraction methods. The final diagnostic accuracy was evaluated by drawing the receiver operating curve (ROC) of each classifier, and the area under each ROC was evaluated. The standard deviations of the tumour area extracted by five dermatologists and 10 non-medical individuals were 8.9% and 10.7%, respectively. After assessment of the extraction results by dermatologists, the STA was defined as the area that was selected by more than two dermatologists. Dermatologists selected the melanoma area with statistically smaller divergence than that of Clark naevus or Reed naevus (P = 0.05). By contrast, non-medical individuals did not show this difference. Our new computer-based extraction algorithm showed superior performance (precision, 94.1%; recall, 95.3%) to the conventional thresholding method (precision, 99.5%; recall, 87.6%). These results indicate that our new algorithm extracted a tumour area close to that obtained by dermatologists and, in particular, the border part of the tumour was adequately extracted. With this refinement, the area under the ROC increased from 0.795 to 0.875 and the diagnostic accuracy showed an increase of approximately 20% in specificity when the sensitivity was 80%. It can be concluded that our computer-based tumour extraction algorithm extracted almost the same area as that obtained by dermatologists and provided improved computer-based diagnostic accuracy.
Malta Barbosa, João; Tovar, Nick; A Tuesta, Pablo; Hirata, Ronaldo; Guimarães, Nuno; Romanini, José C; Moghadam, Marjan; Coelho, Paulo G; Jahangiri, Leila
2017-07-08
This work aims to present a pilot study of a non-destructive dental histo-anatomical analysis technique as well as to push the boundaries of the presently available restorative workflows for the fabrication of highly customized ceramic restorations. An extracted human maxillary central incisor was subject to a micro computed tomography scan and the acquired data was transferred into a workstation, reconstructed, segmented, evaluated and later imported into a Computer-Aided Design/Computer-Aided Manufacturing software for the fabrication of a ceramic resin-bonded prosthesis. The obtained prosthesis presented an encouraging optical behavior and was used clinically as final restoration. The digitally layered restorative replication of natural tooth morphology presents today as a clear possibility. New clinical and laboratory-fabricated, biologically inspired digital restorative protocols are to be expected in the near future. The digitally layered restorative replication of natural tooth morphology presents today as a clear possibility. This pilot study may represent a stimulus for future research and applications of digital imaging as well as digital restorative workflows in service of esthetic dentistry. © 2017 Wiley Periodicals, Inc.
WINCADRE INORGANIC (WINDOWS COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed in...
Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis
2016-01-01
Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356
Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis
2016-01-01
Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.
Vendemia, Nicholas; Chao, Jerry; Ivanidze, Jana; Sanelli, Pina; Spinelli, Henry M
2011-01-01
Medpor (Porex Surgical, Inc, Newnan, GA) is composed of porous polyethylene and is commonly used in craniofacial reconstruction. When complications such as seroma or abscess formation arise, diagnostic modalities are limited because Medpor is radiolucent on conventional radiologic studies. This poses a problem in situations where imaging is necessary to distinguish the implant from surrounding tissues. To present a clinically useful method for imaging Medpor with conventional computed tomographic (CT) scanning. Eleven patients (12 total implants) who have undergone reconstructive surgery with Medpor were included in the study. A retrospective review of CT scans done between 1 and 16 months postoperatively was performed using 3 distinct CT window settings. Measurements of implant dimensions and Hounsfield units were recorded and qualitatively assessed. Of the 3 distinct window settings studied, namely, "bone" (W1100/L450), "soft tissue"; (W500/L50), and "implant" (W800/L200), the implant window proved the most ideal, allowing the investigators to visualize and evaluate Medpor in all cases. Qualitative analysis revealed that Medpor implants were able to be distinguished from surrounding tissue in both the implant and soft tissue windows, with a density falling between that of fat and fluid. In 1 case, Medpor could not be visualized in the soft tissue window, although it could be visualized in the implant window. Quantitative analysis demonstrated a mean (SD) density of -38.7 (7.4) Hounsfield units. Medpor may be optimally visualized on conventional CT scans using the implant window settings W800/L200, which can aid in imaging Medpor and diagnosing implant-related complications.
Chronic Recurrent Non-specific Parotitis: A Case Report and Review.
Mahalakshmi, Saibaba; Kandula, Srinivas; Shilpa, Patil; Kokila, Ganganna
2017-01-01
Chronic recurrent non-specific parotitis is characterized by recurrent episodes of swelling and pain of unknown etiology in the parotid gland. Sialography is a hallmark in the diagnosis of salivary gland disorders; newer imaging modalities like CT-Sialography, sialoendoscopy and MRI can be used. Various treatment modalities have been tried, from conservative approach to surgical excision depending on the recurrence rate and severity of the condition. Although symptomatic treatment with antibiotics and analgesic, injection of intraductal medicament, aggressive treatment like duct ligation or excision of gland are some of the treatment modalities, there is no established algorithm as to which treatment method should be opted in such clinical situation. A 20 years old male patient reported with pain and salty taste in the mouth that had began before a week. Examination revealed an elevated right parotid papilla; ropy, cloudy appearing saliva was oozing out on milking the gland. Unstimulated and stimulated whole salivary flow rate was assessed using drooling method. Sialography was used as a diagnostic and a therapeutic aid. In our case, sialography as a treatment showed a good response with no recurrence after two years of follow-up. We highlighted the role of sialography as a therapeutic aid. Recurrent attacks significantly affect the quality of life and also lead to progressive gland destruction. Preventing or reducing the frequency of recurrence remains the goal of therapeutic procedure. Hence, conventional sialography is useful in the diagnosis and also effective as a therapeutic aid in recurrent parotitis.
Assistive technology use and human rights enjoyment: a cross-sectional study in Bangladesh.
Borg, Johan; Larsson, Stig; Ostergren, Per-Olof; Rahman, Asm Atiqur; Bari, Nazmul; Khan, Ahm Noman
2012-09-19
About half a billion people with disabilities in developing countries have limited access to assistive technology. The Convention on the Rights of persons with Disabilities requires governments to take measures to ensure provision of such technologies. To guide implementation of these measures there is a need for understanding health outcomes from a human rights perspective. The objective of this study was therefore to explore the relation between assistive technology use and enjoyment of human rights in a low-income country. Data was collected in eight districts of Bangladesh through interviews of people with hearing impairments using and not using hearings aids, and people with ambulatory impairments using and not using manual wheelchairs (N = 583). Using logistic regression, self-reported outcomes on standard of living, health, education, work, receiving information and movement were analyzed. The adjusted likelihood of reporting greater enjoyment of human rights was significantly higher among people using hearing aids compared to non-users for all outcomes except working status. Compared to non-users, users of wheelchairs reported a significantly higher adjusted likelihood of good ambulatory performance and a significantly lower adjusted likelihood of reporting a positive working status. Further analyses indicated that physical accessibility to working places and duration of wheelchair use had a statistically significant impact on the likelihood of reporting positive work outcomes. The findings support the notion that assistive technology use increases the likelihood of human rights enjoyment, particularly hearing aid use. Physical accessibility should always be addressed in wheelchair provision.
Semi-Infinite Geology Modeling Algorithm (SIGMA): a Modular Approach to 3D Gravity
NASA Astrophysics Data System (ADS)
Chang, J. C.; Crain, K.
2015-12-01
Conventional 3D gravity computations can take up to days, weeks, and even months, depending on the size and resolution of the data being modeled. Additional modeling runs, due to technical malfunctions or additional data modifications, only compound computation times even further. We propose a new modeling algorithm that utilizes vertical line elements to approximate mass, and non-gridded (point) gravity observations. This algorithm is (1) magnitudes faster than conventional methods, (2) accurate to less than 0.1% error, and (3) modular. The modularity of this methodology means that researchers can modify their geology/terrain or gravity data, and only the modified component needs to be re-run. Additionally, land-, sea-, and air-based platforms can be modeled at their observation point, without having to filter data into a synthesized grid.
Joda, Tim; Brägger, Urs
2015-01-01
To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.
Van Hemelen, Geert; Van Genechten, Maarten; Renier, Lieven; Desmedt, Maria; Verbruggen, Elric; Nadjmi, Nasser
2015-07-01
Throughout the history of computing, shortening the gap between the physical and digital world behind the screen has always been strived for. Recent advances in three-dimensional (3D) virtual surgery programs have reduced this gap significantly. Although 3D assisted surgery is now widely available for orthognathic surgery, one might still argue whether a 3D virtual planning approach is a better alternative to a conventional two-dimensional (2D) planning technique. The purpose of this study was to compare the accuracy of a traditional 2D technique and a 3D computer-aided prediction method. A double blind randomised prospective study was performed to compare the prediction accuracy of a traditional 2D planning technique versus a 3D computer-aided planning approach. The accuracy of the hard and soft tissue profile predictions using both planning methods was investigated. There was a statistically significant difference between 2D and 3D soft tissue planning (p < 0.05). The statistically significant difference found between 2D and 3D planning and the actual soft tissue outcome was not confirmed by a statistically significant difference between methods. The 3D planning approach provides more accurate soft tissue planning. However, the 2D orthognathic planning is comparable to 3D planning when it comes to hard tissue planning. This study provides relevant results for choosing between 3D and 2D planning in clinical practice. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Analysis of computer-aided techniques for virtual planning in nasoalveolar moulding.
Loeffelbein, D J; Ritschl, L M; Rau, A; Wolff, K-D; Barbarino, M; Pfeifer, S; Schönberger, M; Wintermantel, E
2015-05-01
We compared two methods of planning virtual alveolar moulding as the first step in nasoalveolar moulding to provide the basis for an automated process to fabricate nasoalveolar moulding appliances by using computer-assisted design and computer-aided manufacturing (CAD/CAM). First, the initial intraoral casts taken from seven newborn babies with complete unilateral cleft lip and palate were digitised. This was repeated for the target models after conventional nasoalveolar moulding had been completed. The initial digital model for each patient was then virtually modified by two different modelling techniques to achieve the corresponding target model: parametric and freeform modelling with the software Geomagic(®). The digitally-remodelled casts were quantitatively compared with the actual target model for each patient, and the comparison between the two modified models and the target model showed that freeform modelling of the initial cast was successful (mean (SD) deviation n=7, +0.723 (0.148) to -0.694 (0.157)mm) but needed continuous orientation and was difficult to automate. The results from the parametric modelling (mean (SD) deviation, n=7, +1.168 (0.185) to -1.067 (0.221)mm) were not as good as those from freeform modelling. During parametric modelling, we found some irregularities on the surface, and transverse growth of the maxilla was not accounted for. However, this method seems to be the right one as far as automation is concerned. In addition, an external algorithm must be implemented because the function of the commercial software is limited. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Time-Of-Flight Camera, Optical Tracker and Computed Tomography in Pairwise Data Registration.
Pycinski, Bartlomiej; Czajkowska, Joanna; Badura, Pawel; Juszczyk, Jan; Pietka, Ewa
2016-01-01
A growing number of medical applications, including minimal invasive surgery, depends on multi-modal or multi-sensors data processing. Fast and accurate 3D scene analysis, comprising data registration, seems to be crucial for the development of computer aided diagnosis and therapy. The advancement of surface tracking system based on optical trackers already plays an important role in surgical procedures planning. However, new modalities, like the time-of-flight (ToF) sensors, widely explored in non-medical fields are powerful and have the potential to become a part of computer aided surgery set-up. Connection of different acquisition systems promises to provide a valuable support for operating room procedures. Therefore, the detailed analysis of the accuracy of such multi-sensors positioning systems is needed. We present the system combining pre-operative CT series with intra-operative ToF-sensor and optical tracker point clouds. The methodology contains: optical sensor set-up and the ToF-camera calibration procedures, data pre-processing algorithms, and registration technique. The data pre-processing yields a surface, in case of CT, and point clouds for ToF-sensor and marker-driven optical tracker representation of an object of interest. An applied registration technique is based on Iterative Closest Point algorithm. The experiments validate the registration of each pair of modalities/sensors involving phantoms of four various human organs in terms of Hausdorff distance and mean absolute distance metrics. The best surface alignment was obtained for CT and optical tracker combination, whereas the worst for experiments involving ToF-camera. The obtained accuracies encourage to further develop the multi-sensors systems. The presented substantive discussion concerning the system limitations and possible improvements mainly related to the depth information produced by the ToF-sensor is useful for computer aided surgery developers.
The Role of Nicotine Dependence in E-Cigarettes' Potential for Smoking Reduction.
Selya, Arielle S; Dierker, Lisa; Rose, Jennifer S; Hedeker, Donald; Mermelstein, Robin J
2017-07-07
E-cigarettes (Electronic Nicotine Delivery Systems, or ENDS) are an increasingly popular tobacco product among youth. Some evidence suggests that e-cigarettes may be effective for harm reduction and smoking cessation, although these claims remain controversial. Little is known about how nicotine dependence may contribute to e-cigarettes' effectiveness in reducing or quitting conventional smoking. A cohort of young adults were surveyed over 4 years (approximately ages 19-23). Varying-coefficient models (VCMs) were used to examine the relationship between e-cigarette use and conventional smoking frequency, and how this relationship varies across users with different nicotine dependence levels. Lifetime, but not recent, e-cigarette use was associated with less frequent concurrent smoking of conventional cigarettes among those with high levels of nicotine dependence. However, nondependent e-cigarette users smoked conventional cigarettes slightly more frequently than those who had never used e-cigarettes. Nearly half of ever e-cigarette users reported using them to quit smoking at the last measurement wave. For those who used e-cigarettes in a cessation attempt, the frequency of e-cigarette use was not associated with reductions in future conventional smoking frequency. These findings offer possible support that e-cigarettes may act as a smoking reduction method among highly nicotine-dependent young adult cigarette smokers. However, the opposite was found in non-dependent smokers, suggesting that e-cigarette use should be discouraged among novice tobacco users. Additionally, although a substantial proportion of young adults used e-cigarettes to help them quit smoking, these self-initiated quit attempts with e-cigarettes were not associated with future smoking reduction or cessation. This study offers potential support for e-cigarettes as a smoking reduction tool among highly nicotine-dependent young adult conventional smokers, although the extent and nature of this remains unclear. The use of e-cigarettes as a quit aid was not associated with reductions in conventional smoking, consistent with most other quit aids in this sample except for nicotine replacement therapy, which was only effective for the most dependent smokers. Notably, these findings highlight the necessity of accounting for smokers' nicotine dependence levels when examining tobacco use patterns. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Marques do Carmo, Diego; Costa, Márcio Holsbach
2018-04-01
This work presents an online approximation method for the multichannel Wiener filter (MWF) noise reduction technique with preservation of the noise interaural level difference (ILD) for binaural hearing-aids. The steepest descent method is applied to a previously proposed MWF-ILD cost function to both approximate the optimal linear estimator of the desired speech and keep the subjective perception of the original acoustic scenario. The computational cost of the resulting algorithm is estimated in terms of multiply and accumulate operations, whose number can be controlled by setting the number of iterations at each time frame. Simulation results for the particular case of one speech and one-directional noise source show that the proposed method increases the signal-to-noise ratio SNR of the originally acquired speech by up to 16.9 dB in the assessed scenarios. As compared to the online implementation of the conventional MWF technique, the proposed technique provides a reduction of up to 7 dB in the noise ILD error at the price of a reduction of up 3 dB in the output SNR. Subjective experiments with volunteers complement these objective measures with psychoacoustic results, which corroborate the expected spatial preservation of the original acoustic scenario. The proposed method allows practical online implementation of the MWF-ILD noise reduction technique under constrained computational resources. Predicted SNR improvements from 12 dB to 16.9 dB can be obtained in application-specific integrated circuits for hearing-aids and state-of-the-art digital signal processors. Copyright © 2018 Elsevier Ltd. All rights reserved.
Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography
NASA Astrophysics Data System (ADS)
Einarsdóttir, Hildur; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Hellbach, Katharina; Auweter, Sigrid; Yildirim, Önder; Meinel, Felix G.; Eickelberg, Oliver; Reiser, Maximilian; Larsen, Rasmus; Kjær Ersbøll, Bjarne; Pfeiffer, Franz
2015-12-01
In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63 ± 3.65%, Dice Similarity Coefficient (DSC) 89.74 ± 8.84% and Jaccard Similarity Coefficient 82.39 ± 12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected.
Advances in computer-aided well-test interpretation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horne, R.N.
1994-07-01
Despite the feeling expressed several times over the past 40 years that well-test analysis had reached it peak development, an examination of recent advances shows continuous expansion in capability, with future improvement likely. The expansion in interpretation capability over the past decade arose mainly from the development of computer-aided techniques, which, although introduced 20 years ago, have come into use only recently. The broad application of computer-aided interpretation originated with the improvement of the methodologies and continued with the expansion in computer access and capability that accompanied the explosive development of the microcomputer industry. This paper focuses on the differentmore » pieces of the methodology that combine to constitute a computer-aided interpretation and attempts to compare some of the approaches currently used. Future directions of the approach are also discussed. The separate areas discussed are deconvolution, pressure derivatives, model recognition, nonlinear regression, and confidence intervals.« less
Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses
Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn
2016-01-01
Background Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. Objective The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Methods Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Results Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than others. Integration of content control improved quality of decision making (SMD 0.59 vs 0.23 for knowledge; SMD 0.39 vs 0.29 for decisional conflict). In contrast, tailoring reduced quality of decision making (SMD 0.40 vs 0.71 for knowledge; SMD 0.25 vs 0.52 for decisional conflict). Similarly, patient narratives also reduced quality of decision making (SMD 0.43 vs 0.65 for knowledge; SMD 0.17 vs 0.46 for decisional conflict). Results were varied for different types of explicit values clarification, feedback, and social support. Conclusions Integration of media rich or interactive features into computer-based decision aids can improve quality of preference-sensitive decision making. However, this is an emerging field with limited evidence to guide use. The systematic review and thematic synthesis identified features that have been integrated into available computer-based decision aids, in an effort to facilitate reporting of these features and to promote integration of such features into decision aids. The meta-analyses and associated subgroup analyses provide preliminary evidence to support integration of specific features into future decision aids. Further research can focus on clarifying independent contributions of specific features through experimental designs and refining the designs of features to improve effectiveness. PMID:26813512
Towards a 'siliconeural computer': technological successes and challenges.
Hughes, Mark A; Shipston, Mike J; Murray, Alan F
2015-07-28
Electronic signals govern the function of both nervous systems and computers, albeit in different ways. As such, hybridizing both systems to create an iono-electric brain-computer interface is a realistic goal; and one that promises exciting advances in both heterotic computing and neuroprosthetics capable of circumventing devastating neuropathology. 'Neural networks' were, in the 1980s, viewed naively as a potential panacea for all computational problems that did not fit well with conventional computing. The field bifurcated during the 1990s into a highly successful and much more realistic machine learning community and an equally pragmatic, biologically oriented 'neuromorphic computing' community. Algorithms found in nature that use the non-synchronous, spiking nature of neuronal signals have been found to be (i) implementable efficiently in silicon and (ii) computationally useful. As a result, interest has grown in techniques that could create mixed 'siliconeural' computers. Here, we discuss potential approaches and focus on one particular platform using parylene-patterned silicon dioxide.
Students’ Spatial Ability through Open-Ended Approach Aided by Cabri 3D
NASA Astrophysics Data System (ADS)
Priatna, N.
2017-09-01
The use of computer software such as Cabri 3D for learning activities is very unlimited. Students can adjust their learning speed according to their level of ability. Open-ended approach strongly supports the use of computer software in learning, because the goal of open-ended learning is to help developing creative activities and mathematical mindset of students through problem solving simultaneously. In other words, creative activities and mathematical mindset of students should be developed as much as possible in accordance with the ability of spatial ability of each student. Spatial ability is the ability of students in constructing and representing geometry models. This study aims to determine the improvement of spatial ability of junior high school students who obtained learning with open-ended approach aided by Cabri 3D. It adopted a quasi-experimental method with the non-randomized control group pretest-posttest design and the 2×3 factorial model. The instrument of the study is spatial ability test. Based on analysis of the data, it is found that the improvement of spatial ability of students who received open-ended learning aided by Cabri 3D was greater than students who received expository learning, both as a whole and based on the categories of students’ initial mathematical ability.
Digital Michigan splint - from intraoral scanning to plasterless manufacturing.
Dedem, Philipp; Türp, Jens C
2016-01-01
To investigate whether the fully digital, plasterless fabrication of clinically usable Michigan splints can be accomplished in a time- and cost-efficient manner. Digital scans of the maxillary and mandibular arches of 10 subjects were acquired with an intraoral scanner (3Shape, Copenhagen) and used to generate virtual models of the dental arches. Jaw relation records were made using jigs placed on the subjects' anterior teeth, and silicone registration material was referenced to the jaw models. The data sets were then sent via the company's online portal to the dental laboratory, where computer-aided design (CAD) of the Michigan-type maxillary splints was performed. After receiving the designs, the splints were milled in-office using computer-aided manufacturing (CAM) software, and finished manually. During try-in, the splints where checked for fit, retention quality, and occlusal contacts of the mandibular teeth on the splint surfaces in static and dynamic occlusion. Fit and retention were clinically acceptable in 10 splints and 9 splints, respectively. The number of initial occlusal contacts on the splint surfaces ranged from 4 to 16. The question addressed in this study can be answered in the affirmative. Some of the main advantages of digital manufacturing of Michigan splints over traditional, conventional, impression-based manufacturing are the time-efficient manufacturing process, the high material quality, and the possibility of manufacturing duplicate splints.
Developing an Intelligent Computer-Aided Trainer
NASA Technical Reports Server (NTRS)
Hua, Grace
1990-01-01
The Payload-assist module Deploys/Intelligent Computer-Aided Training (PD/ICAT) system was developed as a prototype for intelligent tutoring systems with the intention of seeing PD/ICAT evolve and produce a general ICAT architecture and development environment that can be adapted by a wide variety of training tasks. The proposed architecture is composed of a user interface, a domain expert, a training session manager, a trainee model and a training scenario generator. The PD/ICAT prototype was developed in the LISP environment. Although it has been well received by its peers and users, it could not be delivered toe its end users for practical use because of specific hardware and software constraints. To facilitate delivery of PD/ICAT to its users and to prepare for a more widely accepted development and delivery environment for future ICAT applications, we have ported this training system to a UNIX workstation and adopted use of a conventional language, C, and a C-based rule-based language, CLIPS. A rapid conversion of the PD/ICAT expert system to CLIPS was possible because the knowledge was basically represented as a forward chaining rule base. The resulting CLIPS rule base has been tested successfully in other ICATs as well. Therefore, the porting effort has proven to be a positive step toward our ultimate goal of building a general purpose ICAT development environment.
Computer-aided sperm analysis: a useful tool to evaluate patient's response to varicocelectomy.
Ariagno, Julia I; Mendeluk, Gabriela R; Furlan, María J; Sardi, M; Chenlo, P; Curi, Susana M; Pugliese, Mercedes N; Repetto, Herberto E; Cohen, Mariano
2017-01-01
Preoperative and postoperative sperm parameter values from infertile men with varicocele were analyzed by computer-aided sperm analysis (CASA) to assess if sperm characteristics improved after varicocelectomy. Semen samples of men with proven fertility (n = 38) and men with varicocele-related infertility (n = 61) were also analyzed. Conventional semen analysis was performed according to WHO (2010) criteria and a CASA system was employed to assess kinetic parameters and sperm concentration. Seminal parameters values in the fertile group were very far above from those of the patients, either before or after surgery. No significant improvement in the percentage normal sperm morphology (P = 0.10), sperm concentration (P = 0.52), total sperm count (P = 0.76), subjective motility (%) (P = 0.97) nor kinematics (P = 0.30) was observed after varicocelectomy when all groups were compared. Neither was significant improvement found in percentage normal sperm morphology (P = 0.91), sperm concentration (P = 0.10), total sperm count (P = 0.89) or percentage motility (P = 0.77) after varicocelectomy in paired comparisons of preoperative and postoperative data. Analysis of paired samples revealed that the total sperm count (P = 0.01) and most sperm kinetic parameters: curvilinear velocity (P = 0.002), straight-line velocity (P = 0.0004), average path velocity (P = 0.0005), linearity (P = 0.02), and wobble (P = 0.006) improved after surgery. CASA offers the potential for accurate quantitative assessment of each patient's response to varicocelectomy.
van Zelst, J C M; Tan, T; Platel, B; de Jong, M; Steenbakkers, A; Mourits, M; Grivegnee, A; Borelli, C; Karssemeijer, N; Mann, R M
2017-04-01
To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n=40) with >1year of follow up, benign (n=30) lesions that were either biopsied or remained stable, and malignant lesions (n=20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p=0.001). Sensitivity of all readers improved (range 5.2-10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4-5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer. Copyright © 2017 Elsevier B.V. All rights reserved.
A first experience with digital complete overdentures.
Bajunaid, Salwa Omar
2016-07-01
The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.
Lannsjö, Marianne; Raininko, Raili; Bustamante, Mariana; von Seth, Charlotta; Borg, Jörgen
2013-09-01
To explore brain pathology after mild traumatic brain injury by repeated magnetic resonance examination. A prospective follow-up study. Nineteen patients with mild traumatic brain injury presenting with Glasgow Coma Scale (GCS) 14-15. The patients were examined on day 2 or 3 and 3-7 months after the injury. The magnetic resonance protocol comprised conventional T1- and T2-weighted sequences including fluid attenuated inversion recovery (FLAIR), two susceptibility-weighted sequences to reveal haemorrhages, and diffusion-weighted sequences. Computer-aided volume comparison was performed. Clinical outcome was assessed by the Rivermead Post-Concussion Symptoms Questionnaire (RPQ), Hospital Anxiety and Depression Scale (HADS) and Glasgow Outcome Scale Extended (GOSE). At follow-up, 7 patients (37%) reported ≥ 3 symptoms in RPQ, 5 reported some anxiety and 1 reported mild depression. Fifteen patients reported upper level of good recovery and 4 patients lower level of good recovery (GOSE 8 and 7, respectively). Magnetic resonance pathology was found in 1 patient at the first examination, but 4 patients (21%) showed volume loss at the second examination, at which 3 of them reported < 3 symptoms and 1 ≥ 3 symptoms, all exhibiting GOSE scores of 8. Loss of brain volume, demonstrated by computer-aided magnetic resonance imaging volumetry, may be a feasible marker of brain pathology after mild traumatic brain injury.
Deep ensemble learning of virtual endoluminal views for polyp detection in CT colonography
NASA Astrophysics Data System (ADS)
Umehara, Kensuke; Näppi, Janne J.; Hironaka, Toru; Regge, Daniele; Ishida, Takayuki; Yoshida, Hiroyuki
2017-03-01
Robust training of a deep convolutional neural network (DCNN) requires a very large number of annotated datasets that are currently not available in CT colonography (CTC). We previously demonstrated that deep transfer learning provides an effective approach for robust application of a DCNN in CTC. However, at high detection accuracy, the differentiation of small polyps from non-polyps was still challenging. In this study, we developed and evaluated a deep ensemble learning (DEL) scheme for reviewing of virtual endoluminal images to improve the performance of computer-aided detection (CADe) of polyps in CTC. Nine different types of image renderings were generated from virtual endoluminal images of polyp candidates detected by a conventional CADe system. Eleven DCNNs that represented three types of publically available pre-trained DCNN models were re-trained by transfer learning to identify polyps from the virtual endoluminal images. A DEL scheme that determines the final detected polyps by a review of the nine types of VE images was developed by combining the DCNNs using a random forest classifier as a meta-classifier. For evaluation, we sampled 154 CTC cases from a large CTC screening trial and divided the cases randomly into a training dataset and a test dataset. At 3.9 falsepositive (FP) detections per patient on average, the detection sensitivities of the conventional CADe system, the highestperforming single DCNN, and the DEL scheme were 81.3%, 90.7%, and 93.5%, respectively, for polyps ≥6 mm in size. For small polyps, the DEL scheme reduced the number of false positives by up to 83% over that of using a single DCNN alone. These preliminary results indicate that the DEL scheme provides an effective approach for improving the polyp detection performance of CADe in CTC, especially for small polyps.
ERIC Educational Resources Information Center
Lintz, Larry M.; And Others
This study investigated the feasibility of a low cost computer-aided instruction/computer-managed instruction (CAI/CMI) system. Air Force instructors and training supervisors were surveyed to determine the potential payoffs of various CAI and CMI functions. Results indicated that a wide range of capabilities had potential for resident technical…
ERIC Educational Resources Information Center
Pollard, Jim
This report reviews software packages for Apple Macintosh and Apple II computers available to secondary schools to teach computer-aided drafting (CAD). Products for the report were gathered through reviews of CAD periodicals, computers in education periodicals, advertisements, and teacher recommendations. The first section lists the primary…
A novel productivity-driven logic element for field-programmable devices
NASA Astrophysics Data System (ADS)
Marconi, Thomas; Bertels, Koen; Gaydadjiev, Georgi
2014-06-01
Although various techniques have been proposed for power reduction in field-programmable devices (FPDs), they are still all based on conventional logic elements (LEs). In the conventional LE, the output of the combinational logic (e.g. the look-up table (LUT) in many field-programmable gate arrays (FPGAs)) is connected to the input of the storage element; while the D flip-flop (DFF) is always clocked even when not necessary. Such unnecessary transitions waste power. To address this problem, we propose a novel productivity-driven LE with reduced number of transitions. The differences between our LE and the conventional LE are in the FFs-type used and the internal LE organisation. In our LEs, DFFs have been replaced by T flip-flops with the T input permanently connected to logic value 1. Instead of connecting the output of the combinational logic to the FF input, we use it as the FF clock. The proposed LE has been validated via Simulation Program with Integrated Circuit Emphasis (SPICE) simulations for a 45-nm Complementary Metal-Oxide-Semiconductor (CMOS) technology as well as via a real Computer-Aided Design (CAD) tools on a real FPGA using the standard Microelectronic Center of North Carolina (MCNC) benchmark circuits. The experimental results show that FPDs using our proposal not only have 48% lower total power but also run 17% faster than conventional FPDs on average.
Computer Aided Drug Design: Success and Limitations.
Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho
2016-01-01
Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.
NASA Astrophysics Data System (ADS)
Christensen, Gary E.; Williamson, Jeffrey F.; Chao, K. S. C.; Miller, Michael I.; So, F. B.; Vannier, Michael W.
1997-10-01
This paper describes a new method to register serial, volumetric x-ray computed tomography (CT) data sets for tracking soft-tissue deformation caused by insertion of intracavity brachytherapy applicators to treat cervical cancer. 3D CT scans collected from the same patient with and without a brachytherapy applicator are registered to aid in computation of the radiation dose to tumor and normal tissue. The 3D CT image volume of pelvic anatomy with the applicator. Initial registration is accomplished by rigid alignment of the pelvic bones and non-rigid alignment of gray scale CT data and hand segmentations of the vagina, cervix, bladder, and rectum. A viscous fluid transformation model is used for non-rigid registration to allow for local, non-linear registration of the vagina, cervix, bladder, and rectum without disturbing the rigid registration of the bony pelvis and adjacent structures. Results are presented in which two 3D CT data sets of the same patient - imaged with and without a brachytherapy applicator - are registered.
Web-Based Learning in the Computer-Aided Design Curriculum.
ERIC Educational Resources Information Center
Sung, Wen-Tsai; Ou, S. C.
2002-01-01
Applies principles of constructivism and virtual reality (VR) to computer-aided design (CAD) curriculum, particularly engineering, by integrating network, VR and CAD technologies into a Web-based learning environment that expands traditional two-dimensional computer graphics into a three-dimensional real-time simulation that enhances user…
Integrated Computer-Aided Drafting Instruction (ICADI).
ERIC Educational Resources Information Center
Chen, C. Y.; McCampbell, David H.
Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…
A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics
2006-05-01
Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography
Computer-aided design of the RF-cavity for a high-power S-band klystron
NASA Astrophysics Data System (ADS)
Kant, D.; Bandyopadhyay, A. K.; Pal, D.; Meena, R.; Nangru, S. C.; Joshi, L. M.
2012-08-01
This article describes the computer-aided design of the RF-cavity for a S-band klystron operating at 2856 MHz. State-of-the-art electromagnetic simulation tools SUPERFISH, CST Microwave studio, HFSS and MAGIC have been used for cavity design. After finalising the geometrical details of the cavity through simulation, it has been fabricated and characterised through cold testing. Detailed results of the computer-aided simulation and cold measurements are presented in this article.
Computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems
NASA Astrophysics Data System (ADS)
Ku, Walter H.; Gang, Guan-Wan; He, J. Q.; Ichitsubo, I.
1988-05-01
This final technical report presents results on the computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems. New results include analytical and computer aided device models of GaAs MESFETs and HEMTs or MODFETs, new synthesis techniques for monolithic feedback and distributed amplifiers and a new nonlinear CAD program for MIMIC called CADNON. This program incorporates the new MESFET and HEMT model and has been successfully applied to the design of monolithic millimeter-wave mixers.
An Interactive Computer Aided Design and Analysis Package.
1986-03-01
Al-A167 114 AN INTERACTIVE COMPUTER AIDED DESIGN MUD ANAILYSIS 1/ PACKAGE(U) NAVAL POSTGRADUATE SCHOOL NONTEREY CA T L EUALD "AR 86 UNCLSSIFIED F... SCHOOL Monterey, California DTIC .LECTE MAYOS THESIS AN INTERACTIVE COMPUTER AIDED DESIGN AND ANALYSIS PACKAGE by Terrence L. Ewald March 1986 jThesis...ORGANIZATION Naval Postgraduate School (if dAp90h81111) Naval Postgraduate School . 62A 6C. ADDRESS (0ty. State, and ZIP Code) 7b. ADDRESS (City State. and
Enk, D; Enk, E
1995-11-01
Various in vitro models have been introduced for comparative examinations of post-dural-puncture trauma and measurement of liquor leakage through puncture sites. These models allow simulation of subarachnoid, but not of peridural, pressure. A new two-chamber-model realizes the simulation of both subarachnoid and peridural pressure and allows observation of in vitro punctures with video-documentation. Frame grabbing and (computer-aided) image analysis show new aspects of spinal puncture effects. Therefore, post-dural-puncture trauma and retraction can be objectively visualized by this method, which has not previously been demonstrated. Two-chamber-model consists of two short aluminium cylinders. Native human dura patches (8X8 mm) from fresh cadavers are put (correctly oriented) between two special polyamide seals. Mounted between the upper and lower cylinder, these seals stretch the dura patch, which remains flexible and even in all directions. After filling of the lower (subarachnoid) and upper (peridural) chamber with Ringer lactate solution, positive or negative physiological pressure can be adjusted by way of two (Ringer lactate solution filled) infusion lines in each chamber. Puncturing is performed at an angle of 57 degrees to the dura. The model allows examination with epi-illumination and transmitted (polarized) light. In vitro punctures are observed through an inverted camera lens with an CCD-Hi8 video camera (Canon UC1HI) looking into the peridural chamber and documented by means of an S-VHS video recorder (Panasonic NV-FS200EG). After true-colour frame grabbing by a video digitizer (Fast Screen Machine II), single video frames can be optimized and analysed with a 486-66 MHz computer and conventional software (Corel Draw 3.0, Photostyler 1.1a, DDL Aequitas 1.00b). Punctures demonstrated in this paper have been done under simulation of a transdural gradient of 20 cm water similar to the situation of a recumbent patient (15 cm water in the subarachnoid and -5 cm water in the peridural chamber). The punctures were followed by short-time observation for up to 10 minutes. By making it possible to obtains a picture of the puncture site at 20-ms intervals (because of the PAL norm of 50 half-frames/s), video-documentation has become accepted as superior to conventional photography. When the Ringer lactate solution in the subarachnoid chamber is stained with methylene blue, transdural leakage can easily be observed. The result of this documentation technique demonstrate that not dural puncture can be atraumatic, when a 29-G Quincke needle is used. Calculation on the difference between a digitized video frame before and after the puncture clearly illustrates the dural trauma. Owing to their non-cutting tip, as expected, pencil-point needles leave diffuse changes across the dura patch, whereas a more local trauma was observed after puncturing with cutting-tip needles. The same computer calculation between two video frames allows examination of post-puncture-dural retraction of the puncture site. In this connection, we found that relevant dural retraction is a phenomenon limited to the first minute after puncture. Thin spinal needles with so-called modern tips (e.g. Whitacre, Atraucan) can minimize the post-dural-puncture trauma, whereas thicker, conventional, spinal needles (Quincke) leave considerable dural defects. The two-chamber-model presented allows easy simulation of physiological subarachnoid and peridural pressure. The Ringer lactate solution in the subarachnoid chamber corresponds to the liquor, whereas that in the peridural chamber corresponds to the intercellular (peridural) space. The tension of the dural patch between the polyamide seals is similar to the situation in an anotomical model observed by spinaloscopy (in an earlier study). With the video documentation and computer-aided analysis technique introduced, dural trauma and retraction of the puncture site can be examined and demo
ERIC Educational Resources Information Center
Proctor, Tony
1988-01-01
Explores the conceptual components of a computer program designed to enhance creative thinking and reviews software that aims to stimulate creative thinking. Discusses BRAIN and ORACLE, programs intended to aid in creative problem solving. (JOW)
Prerequisites for Computer-Aided Cognitive Rehabilitation.
ERIC Educational Resources Information Center
Legrand, Colette
1989-01-01
This paper describes computer-aided cognitive rehabilitation for mentally deficient persons. It lists motor, cognitive, emotional, and educational prerequisites to such rehabilitation and states advantages and disadvantages in using the prerequisites. (JDD)
Computer-aided detection of bladder masses in CT urography (CTU)
NASA Astrophysics Data System (ADS)
Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Samala, Ravi K.
2017-03-01
We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced and the non-contrastenhanced regions of the bladder individually. In this study, we investigated methods for detection of bladder masses within the entire bladder. The bladder was segmented using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates in a prescreening step. The candidates were mapped back to the 3D CT volume and segmented using our auto-initialized cascaded level set (AI-CALS) segmentation method. Twenty-seven morphological features were extracted for each candidate. A data set of 57 patients with 71 biopsy-proven bladder lesions was used, which was split into independent training and test sets: 42 training cases with 52 lesions, and 15 test cases with 19 lesions. Using the training set, feature selection was performed and a linear discriminant (LDA) classifier was designed to merge the selected features for classification of bladder lesions and false positives. The trained classifier was evaluated with the test set. FROC analysis showed that the system achieved a sensitivity of 86.5% at 3.3 FPs/case for the training set, and 84.2% at 3.7 FPs/case for the test set.
Computer-aided detection of bladder mass within non-contrast-enhanced region of CT Urography (CTU)
NASA Astrophysics Data System (ADS)
Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Zhou, Chuan
2016-03-01
We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced region of the bladder. In this study, we investigated methods for detection of bladder masses within the non-contrast enhanced region. The bladder was first segmented using a newly developed deep-learning convolutional neural network in combination with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensityprojection- based method. The non-contrast region was smoothed and a gray level threshold was employed to segment the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates as a prescreening step. The lesion candidates were segmented using our autoinitialized cascaded level set (AI-CALS) segmentation method, and 27 morphological features were extracted for each candidate. Stepwise feature selection with simplex optimization and leave-one-case-out resampling were used for training and validation of a false positive (FP) classifier. In each leave-one-case-out cycle, features were selected from the training cases and a linear discriminant analysis (LDA) classifier was designed to merge the selected features into a single score for classification of the left-out test case. A data set of 33 cases with 42 biopsy-proven lesions in the noncontrast enhanced region was collected. During prescreening, the system obtained 83.3% sensitivity at an average of 2.4 FPs/case. After feature extraction and FP reduction by LDA, the system achieved 81.0% sensitivity at 2.0 FPs/case, and 73.8% sensitivity at 1.5 FPs/case.
ERIC Educational Resources Information Center
Attinasi, Louis C., Jr.; Fenske, Robert H.
1988-01-01
Two computer models used at Arizona State University recognize the tendency of students from low-income and minority backgrounds to apply for assistance late in the funding cycle. They permit administrators to project the amount of aid needed by such students. The Financial Aid Computerized Tracking System is described. (Author/MLW)
ERIC Educational Resources Information Center
Stevenson, Kimberly
This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…
Lippert, Adam M
2015-01-01
To examine the sociodemographic traits of adolescent e-cigarette users and whether e-cigarettes are used as cessation aids among adolescent smokers. The study had a cross-sectional design. Study setting was the United States. A probability sample of 15,264 adolescents in grades 6 through 12 was used. The study measured self-reported lifetime e-cigarette use and recent conventional cigarette use, desire to quit, and number of recent quit attempts (among conventional cigarette smokers), and factors hypothesized to be related to e-cigarette use (e.g., race/ethnicity, age, friendships with smokers). Logistic regression was used to assess e-cigarette use among (1) all adolescents and (2) conventional cigarette smokers as a function of quit desire and attempts. Descriptive analyses show 3.2% of respondents had used e-cigarettes. E-cigarette use is significantly lower for females (adjusted odds ratio [OR], .70), non-Hispanic black youth (adjusted OR, .37), and Mexican-American youth (adjusted OR, .56), and higher for those who smoke conventional cigarettes (adjusted OR, 58.44) or have friends who smoke (adjusted OR, 2.38). Among conventional cigarette smokers, neither desire to quit nor recent quit attempts is significantly associated with e-cigarette use. E-cigarette use is more common among certain adolescent subgroups than others and does not appear to be part of a cessation regimen among conventional cigarette smokers wishing to quit. More regulatory and prevention efforts are needed, especially for certain adolescent subpopulations.
ERIC Educational Resources Information Center
Yetter, Carol J.
2009-01-01
This hearing aid primer is designed to define the differences among the three levels of hearing instrument technology: conventional analog circuit technology (most basic), digitally programmable/analog circuit technology (moderately advanced), and fully digital technology (most advanced). Both moderate and advanced technologies mean that hearing…
Sivanandam, S E; Mathew, Georgie; Bhat, Sanjay H
2009-07-01
Persistent hematuria is one of the most dreaded complications following percutanous nephrolithotomy (PCNL). Although invasive, a catheter-based angiogram is usually used to localize the bleeding vessel and subsequently embolize it. Advances in imaging technology have now made it possible to use a non invasive multi-detector computed tomography (MDCT) angiogram with 3-D reconstruction to establish the diagnosis. We report a case of post-PCNL hemorrhage due to a pseudo aneurysm that was missed by a conventional angiogram and subsequently detected on MDCT angiogram.
Incorporation of CAD/CAM Restoration Into Navy Dentistry
2017-09-26
CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct
ERIC Educational Resources Information Center
Aksakalli, Ayhan; Turgut, Umit; Salar, Riza
2016-01-01
This research aims to investigate the ways in which pre-service physics teachers interact with computers, which, as an indispensable means of today's technology, are of major value in education and training, and to identify any misconceptions said teachers may have about computer-aided instruction. As part of the study, computer-based physics…
Student Performance in Computer-Assisted Instruction in Programming.
ERIC Educational Resources Information Center
Friend, Jamesine E.; And Others
A computer-assisted instructional system to teach college students the computer language, AID (Algebraic Interpretive Dialogue), two control programs, and data collected by the two control programs are described. It was found that although first response errors were often those of AID syntax, such errors were easily corrected. Secondly, while…
Cooperation Support in Computer-Aided Authoring and Learning.
ERIC Educational Resources Information Center
Muhlhauser, Max; Rudebusch, Tom
This paper discusses the use of Computer Supported Cooperative Work (CSCW) techniques for computer-aided learning (CAL); the work was started in the context of project Nestor, a joint effort of German universities about cooperative multimedia authoring/learning environments. There are four major categories of cooperation for CAL: author/author,…
Computer-Assisted Instruction: One Aid for Teachers of Reading.
ERIC Educational Resources Information Center
Rauch, Margaret; Samojeden, Elizabeth
Computer assisted instruction (CAI), an instructional system with direct interaction between the student and the computer, can be a valuable aid for presenting new concepts, for reinforcing of selective skills, and for individualizing instruction. The advantages CAI provides include self-paced learning, more efficient allocation of classroom time,…
NASA Technical Reports Server (NTRS)
Abbott, Kathy H.; Schutte, Paul C.
1989-01-01
A development status evaluation is presented for the NASA-Langley Intelligent Cockpit Aids research program, which encompasses AI, human/machine interfaces, and conventional automation. Attention is being given to decision-aiding concepts for human-centered automation, with emphasis on inflight subsystem fault management, inflight mission replanning, and communications management. The cockpit envisioned is for advanced commercial transport aircraft.
Reid, John A; Mollica, Peter A; Johnson, Garett D; Ogle, Roy C; Bruno, Robert D; Sachs, Patrick C
2016-06-07
The precision and repeatability offered by computer-aided design and computer-numerically controlled techniques in biofabrication processes is quickly becoming an industry standard. However, many hurdles still exist before these techniques can be used in research laboratories for cellular and molecular biology applications. Extrusion-based bioprinting systems have been characterized by high development costs, injector clogging, difficulty achieving small cell number deposits, decreased cell viability, and altered cell function post-printing. To circumvent the high-price barrier to entry of conventional bioprinters, we designed and 3D printed components for the adaptation of an inexpensive 'off-the-shelf' commercially available 3D printer. We also demonstrate via goal based computer simulations that the needle geometries of conventional commercially standardized, 'luer-lock' syringe-needle systems cause many of the issues plaguing conventional bioprinters. To address these performance limitations we optimized flow within several microneedle geometries, which revealed a short tapered injector design with minimal cylindrical needle length was ideal to minimize cell strain and accretion. We then experimentally quantified these geometries using pulled glass microcapillary pipettes and our modified, low-cost 3D printer. This systems performance validated our models exhibiting: reduced clogging, single cell print resolution, and maintenance of cell viability without the use of a sacrificial vehicle. Using this system we show the successful printing of human induced pluripotent stem cells (hiPSCs) into Geltrex and note their retention of a pluripotent state 7 d post printing. We also show embryoid body differentiation of hiPSC by injection into differentiation conducive environments, wherein we observed continuous growth, emergence of various evaginations, and post-printing gene expression indicative of the presence of all three germ layers. These data demonstrate an accessible open-source 3D bioprinter capable of serving the needs of any laboratory interested in 3D cellular interactions and tissue engineering.
Power, discourse, and resistance: Poststructuralist influences in nursing.
Holmes, Dave; Gagnon, Marilou
2018-01-01
Based on our respective research programs (psychiatry, forensic psychiatry, public health, HIV/AIDS, harm reduction) this article aims to use purposely non-conventional means to present the substantial contribution of poststructuralist perspectives to knowledge development in nursing science in general and in our current research in particular. More specifically, we call on the work of Michel Foucault and Deleuze & Guattari to politicize nursing science using examples from our empirical research programs with marginal and often highly marginalized populations. We discuss the concepts of power, discourse, and resistance to illustrate the essential contribution of poststructuralism to marginal, even "nomadic", nursing research. © 2017 John Wiley & Sons Ltd.
2013-01-01
Background Breast cancer is the leading cause of both incidence and mortality in women population. For this reason, much research effort has been devoted to develop Computer-Aided Detection (CAD) systems for early detection of the breast cancers on mammograms. In this paper, we propose a new and novel dictionary configuration underpinning sparse representation based classification (SRC). The key idea of the proposed algorithm is to improve the sparsity in terms of mass margins for the purpose of improving classification performance in CAD systems. Methods The aim of the proposed SRC framework is to construct separate dictionaries according to the types of mass margins. The underlying idea behind our method is that the separated dictionaries can enhance the sparsity of mass class (true-positive), leading to an improved performance for differentiating mammographic masses from normal tissues (false-positive). When a mass sample is given for classification, the sparse solutions based on corresponding dictionaries are separately solved and combined at score level. Experiments have been performed on both database (DB) named as Digital Database for Screening Mammography (DDSM) and clinical Full Field Digital Mammogram (FFDM) DBs. In our experiments, sparsity concentration in the true class (SCTC) and area under the Receiver operating characteristic (ROC) curve (AUC) were measured for the comparison between the proposed method and a conventional single dictionary based approach. In addition, a support vector machine (SVM) was used for comparing our method with state-of-the-arts classifier extensively used for mass classification. Results Comparing with the conventional single dictionary configuration, the proposed approach is able to improve SCTC of up to 13.9% and 23.6% on DDSM and FFDM DBs, respectively. Moreover, the proposed method is able to improve AUC with 8.2% and 22.1% on DDSM and FFDM DBs, respectively. Comparing to SVM classifier, the proposed method improves AUC with 2.9% and 11.6% on DDSM and FFDM DBs, respectively. Conclusions The proposed dictionary configuration is found to well improve the sparsity of dictionaries, resulting in an enhanced classification performance. Moreover, the results show that the proposed method is better than conventional SVM classifier for classifying breast masses subject to various margins from normal tissues. PMID:24564973
Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.
Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T
2018-01-01
Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The asymptotic spectra of banded Toeplitz and quasi-Toeplitz matrices
NASA Technical Reports Server (NTRS)
Beam, Richard M.; Warming, Robert F.
1991-01-01
Toeplitz matrices occur in many mathematical, as well as, scientific and engineering investigations. This paper considers the spectra of banded Toeplitz and quasi-Toeplitz matrices with emphasis on non-normal matrices of arbitrarily large order and relatively small bandwidth. These are the type of matrices that appear in the investigation of stability and convergence of difference approximations to partial differential equations. Quasi-Toeplitz matrices are the result of non-Dirichlet boundary conditions for the difference approximations. The eigenvalue problem for a banded Toeplitz or quasi-Toeplitz matrix of large order is, in general, analytically intractable and (for non-normal matrices) numerically unreliable. An asymptotic (matrix order approaches infinity) approach partitions the eigenvalue analysis of a quasi-Toeplitz matrix into two parts, namely the analysis for the boundary condition independent spectrum and the analysis for the boundary condition dependent spectrum. The boundary condition independent spectrum is the same as the pure Toeplitz matrix spectrum. Algorithms for computing both parts of the spectrum are presented. Examples are used to demonstrate the utility of the algorithms, to present some interesting spectra, and to point out some of the numerical difficulties encountered when conventional matrix eigenvalue routines are employed for non-normal matrices of large order. The analysis for the Toeplitz spectrum also leads to a diagonal similarity transformation that improves conventional numerical eigenvalue computations. Finally, the algorithm for the asymptotic spectrum is extended to the Toeplitz generalized eigenvalue problem which occurs, for example, in the stability of Pade type difference approximations to differential equations.
Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon
2016-03-01
The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, p<0.001). The five- and 10-year survival rates were 97.1% and 89.6%, respectively. No difference was detected in nine-year survival rates (p=0.369) between the two groups, although the clinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.
Computer-aided design of high-frequency transistor amplifiers.
NASA Technical Reports Server (NTRS)
Hsieh, C.-C.; Chan, S.-P.
1972-01-01
A systematic step-by-step computer-aided procedure for designing high-frequency transistor amplifiers is described. The technique makes it possible to determine the optimum source impedance which gives a minimum noise figure.
NASA Astrophysics Data System (ADS)
An, Chan-Ho; Yang, Janghoon; Jang, Seunghun; Kim, Dong Ku
In this letter, a pre-processed lattice reduction (PLR) scheme is developed for the lattice reduction aided (LRA) detection of multiple input multiple-output (MIMO) systems in spatially correlated channel. The PLR computes the LLL-reduced matrix of the equivalent matrix, which is the product of the present channel matrix and unimodular transformation matrix for LR of spatial correlation matrix, rather than the present channel matrix itself. In conjunction with PLR followed by recursive lattice reduction (RLR) scheme [7], pre-processed RLR (PRLR) is shown to efficiently carry out the LR of the channel matrix, especially for the burst packet message in spatially and temporally correlated channel while matching the performance of conventional LRA detection.
A Succinct Naming Convention for Lengthy Hexadecimal Numbers
NASA Technical Reports Server (NTRS)
Grant, Michael S.
1997-01-01
Engineers, computer scientists, mathematicians and others must often deal with lengthy hexadecimal numbers. As memory requirements for software increase, the associated memory address space for systems necessitates the use of longer and longer strings of hexadecimal characters to describe a given number. For example, the address space of some digital signal processors (DSP's) now ranges in the billions of words, requiring eight hexadecimal characters for many of the addresses. This technical memorandum proposes a simple grouping scheme for more clearly representing lengthy hexadecimal numbers in written material, as well as a "code" for naming and more quickly verbalizing such numbers. This should facilitate communications among colleagues in engineering and related fields, and aid in comprehension and temporary memorization of important hexadecimal numbers during design work.
Subsonic Wing Optimization for Handling Qualities Using ACSYNT
NASA Technical Reports Server (NTRS)
Soban, Danielle Suzanne
1996-01-01
The capability to accurately and rapidly predict aircraft stability derivatives using one comprehensive analysis tool has been created. The PREDAVOR tool has the following capabilities: rapid estimation of stability derivatives using a vortex lattice method, calculation of a longitudinal handling qualities metric, and inherent methodology to optimize a given aircraft configuration for longitudinal handling qualities, including an intuitive graphical interface. The PREDAVOR tool may be applied to both subsonic and supersonic designs, as well as conventional and unconventional, symmetric and asymmetric configurations. The workstation-based tool uses as its model a three-dimensional model of the configuration generated using a computer aided design (CAD) package. The PREDAVOR tool was applied to a Lear Jet Model 23 and the North American XB-70 Valkyrie.
Three-dimensional surgical simulation.
Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael
2010-09-01
In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
A hybrid multi-objective evolutionary algorithm for wind-turbine blade optimization
NASA Astrophysics Data System (ADS)
Sessarego, M.; Dixon, K. R.; Rival, D. E.; Wood, D. H.
2015-08-01
A concurrent-hybrid non-dominated sorting genetic algorithm (hybrid NSGA-II) has been developed and applied to the simultaneous optimization of the annual energy production, flapwise root-bending moment and mass of the NREL 5 MW wind-turbine blade. By hybridizing a multi-objective evolutionary algorithm (MOEA) with gradient-based local search, it is believed that the optimal set of blade designs could be achieved in lower computational cost than for a conventional MOEA. To measure the convergence between the hybrid and non-hybrid NSGA-II on a wind-turbine blade optimization problem, a computationally intensive case was performed using the non-hybrid NSGA-II. From this particular case, a three-dimensional surface representing the optimal trade-off between the annual energy production, flapwise root-bending moment and blade mass was achieved. The inclusion of local gradients in the blade optimization, however, shows no improvement in the convergence for this three-objective problem.
Space Spurred Computer Graphics
NASA Technical Reports Server (NTRS)
1983-01-01
Dicomed Corporation was asked by NASA in the early 1970s to develop processing capabilities for recording images sent from Mars by Viking spacecraft. The company produced a film recorder which increased the intensity levels and the capability for color recording. This development led to a strong technology base resulting in sophisticated computer graphics equipment. Dicomed systems are used to record CAD (computer aided design) and CAM (computer aided manufacturing) equipment, to update maps and produce computer generated animation.
Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret
2008-01-01
The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.
Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng
2018-02-15
To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.
Hoque, Dewan Md Emdadul; Islam, Md Irteja; Sharmin Salam, Shumona; Rahman, Qazi Sadeq-Ur; Agrawal, Priyanka; Rahman, Aminur; Rahman, Fazlur; El-Arifeen, Shams; Hyder, Adnan A; Alonge, Olakunle
2017-07-12
Non-fatal injuries have a significant impact on disability, productivity, and economic cost, and first-aid can play an important role in improving non-fatal injury outcomes. Data collected from a census conducted as part of a drowning prevention project in Bangladesh was used to quantify the impact of first-aid provided by trained and untrained providers on non-fatal injuries. The census covered approximately 1.2 million people from 7 sub-districts of Bangladesh. Around 10% individuals reported an injury event in the six-month recall period. The most common injuries were falls (39%) and cuts injuries (23.4%). Overall, 81.7% of those with non-fatal injuries received first aid from a provider of whom 79.9% were non-medically trained. Individuals who received first-aid from a medically trained provider had more severe injuries and were 1.28 times more likely to show improvement or recover compared to those who received first-aid from an untrained provider. In Bangladesh, first-aid for non-fatal injuries are primarily provided by untrained providers. Given the large number of untrained providers and the known benefits of first aid to overcome morbidities associated with non-fatal injuries, public health interventions should be designed and implemented to train and improve skills of untrained providers.
Islam, Md Irteja; Sharmin Salam, Shumona; Rahman, Qazi Sadeq-ur; Rahman, Aminur; Rahman, Fazlur; El-Arifeen, Shams; Hyder, Adnan A.; Alonge, Olakunle
2017-01-01
Non-fatal injuries have a significant impact on disability, productivity, and economic cost, and first-aid can play an important role in improving non-fatal injury outcomes. Data collected from a census conducted as part of a drowning prevention project in Bangladesh was used to quantify the impact of first-aid provided by trained and untrained providers on non-fatal injuries. The census covered approximately 1.2 million people from 7 sub-districts of Bangladesh. Around 10% individuals reported an injury event in the six-month recall period. The most common injuries were falls (39%) and cuts injuries (23.4%). Overall, 81.7% of those with non-fatal injuries received first aid from a provider of whom 79.9% were non-medically trained. Individuals who received first-aid from a medically trained provider had more severe injuries and were 1.28 times more likely to show improvement or recover compared to those who received first-aid from an untrained provider. In Bangladesh, first-aid for non-fatal injuries are primarily provided by untrained providers. Given the large number of untrained providers and the known benefits of first aid to overcome morbidities associated with non-fatal injuries, public health interventions should be designed and implemented to train and improve skills of untrained providers. PMID:28704972
ERIC Educational Resources Information Center
Warr, Jeremy G.
1998-01-01
National Vocational Qualifications (NVQs) were used to train 17 nurses' aides. Compared to conventionally trained aides, the NVQ group performed considerably better and in some cases outperformed qualified nurses in the quality of patient care. (SK)
Training Needs Analysis: Weaknesses in the Conventional Approach.
ERIC Educational Resources Information Center
Leat, Michael James; Lovel, Murray Jack
1997-01-01
Identification of the training and development needs of administrative support staff is not aided by conventional performance appraisal, which measures summary or comparative effectiveness. Meaningful diagnostic evaluation integrates three levels of analysis (organization, task, and individual), using behavioral expectation scales. (SK)
Model-based spectral estimation of Doppler signals using parallel genetic algorithms.
Solano González, J; Rodríguez Vázquez, K; García Nocetti, D F
2000-05-01
Conventional spectral analysis methods use a fast Fourier transform (FFT) on consecutive or overlapping windowed data segments. For Doppler ultrasound signals, this approach suffers from an inadequate frequency resolution due to the time segment duration and the non-stationarity characteristics of the signals. Parametric or model-based estimators can give significant improvements in the time-frequency resolution at the expense of a higher computational complexity. This work describes an approach which implements in real-time a parametric spectral estimator method using genetic algorithms (GAs) in order to find the optimum set of parameters for the adaptive filter that minimises the error function. The aim is to reduce the computational complexity of the conventional algorithm by using the simplicity associated to GAs and exploiting its parallel characteristics. This will allow the implementation of higher order filters, increasing the spectrum resolution, and opening a greater scope for using more complex methods.
Effect of Computer-Presented Organizational/Memory Aids on Problem Solving Behavior.
ERIC Educational Resources Information Center
Steinberg, Esther R.; And Others
This research studied the effects of computer-presented organizational/memory aids on problem solving behavior. The aids were either matrix or verbal charts shown on the display screen next to the problem. The 104 college student subjects were randomly assigned to one of the four conditions: type of chart (matrix or verbal chart) and use of charts…
ERIC Educational Resources Information Center
Schulz, Russel E.; And Others
This Programming Design Guide (PDG) was developed to permit the offline Job Aid for Selecting Instructional Setting, which is one of 13 job aids presently available for use with the Instructional Systems Development (ISD) model, to be available in an inquiry-type, online version. It is intended to provide computer programmers with all of the…
Neuromorphic Computing – From Materials Research to Systems Architecture Roundtable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuller, Ivan K.; Stevens, Rick; Pino, Robinson
2015-10-29
Computation in its many forms is the engine that fuels our modern civilization. Modern computation—based on the von Neumann architecture—has allowed, until now, the development of continuous improvements, as predicted by Moore’s law. However, computation using current architectures and materials will inevitably—within the next 10 years—reach a limit because of fundamental scientific reasons. DOE convened a roundtable of experts in neuromorphic computing systems, materials science, and computer science in Washington on October 29-30, 2015 to address the following basic questions: Can brain-like (“neuromorphic”) computing devices based on new material concepts and systems be developed to dramatically outperform conventional CMOS basedmore » technology? If so, what are the basic research challenges for materials sicence and computing? The overarching answer that emerged was: The development of novel functional materials and devices incorporated into unique architectures will allow a revolutionary technological leap toward the implementation of a fully “neuromorphic” computer. To address this challenge, the following issues were considered: The main differences between neuromorphic and conventional computing as related to: signaling models, timing/clock, non-volatile memory, architecture, fault tolerance, integrated memory and compute, noise tolerance, analog vs. digital, and in situ learning New neuromorphic architectures needed to: produce lower energy consumption, potential novel nanostructured materials, and enhanced computation Device and materials properties needed to implement functions such as: hysteresis, stability, and fault tolerance Comparisons of different implementations: spin torque, memristors, resistive switching, phase change, and optical schemes for enhanced breakthroughs in performance, cost, fault tolerance, and/or manufacturability.« less
Teaching Advance Care Planning to Medical Students with a Computer-Based Decision Aid
Levi, Benjamin H.
2013-01-01
Discussing end-of-life decisions with cancer patients is a crucial skill for physicians. This article reports findings from a pilot study evaluating the effectiveness of a computer-based decision aid for teaching medical students about advance care planning. Second-year medical students at a single medical school were randomized to use a standard advance directive or a computer-based decision aid to help patients with advance care planning. Students' knowledge, skills, and satisfaction were measured by self-report; their performance was rated by patients. 121/133 (91%) of students participated. The Decision-Aid Group (n=60) outperformed the Standard Group (n=61) in terms of students´ knowledge (p<0.01), confidence in helping patients with advance care planning (p<0.01), knowledge of what matters to patients (p=0.05), and satisfaction with their learning experience (p<0.01). Likewise, patients in the Decision Aid Group were more satisfied with the advance care planning method (p<0.01) and with several aspects of student performance. Use of a computer-based decision aid may be an effective way to teach medical students how to discuss advance care planning with cancer patients. PMID:20632222
Computational modelling of the impact of AIDS on business.
Matthews, Alan P
2007-07-01
An overview of computational modelling of the impact of AIDS on business in South Africa, with a detailed description of the AIDS Projection Model (APM) for companies, developed by the author, and suggestions for further work. Computational modelling of the impact of AIDS on business in South Africa requires modelling of the epidemic as a whole, and of its impact on a company. This paper gives an overview of epidemiological modelling, with an introduction to the Actuarial Society of South Africa (ASSA) model, the most widely used such model for South Africa. The APM produces projections of HIV prevalence, new infections, and AIDS mortality on a company, based on the anonymous HIV testing of company employees, and projections from the ASSA model. A smoothed statistical model of the prevalence test data is computed, and then the ASSA model projection for each category of employees is adjusted so that it matches the measured prevalence in the year of testing. FURTHER WORK: Further techniques that could be developed are microsimulation (representing individuals in the computer), scenario planning for testing strategies, and models for the business environment, such as models of entire sectors, and mapping of HIV prevalence in time and space, based on workplace and community data.
Jürgens, Tim; Clark, Nicholas R; Lecluyse, Wendy; Meddis, Ray
2016-01-01
To use a computer model of impaired hearing to explore the effects of a physiologically-inspired hearing-aid algorithm on a range of psychoacoustic measures. A computer model of a hypothetical impaired listener's hearing was constructed by adjusting parameters of a computer model of normal hearing. Absolute thresholds, estimates of compression, and frequency selectivity (summarized to a hearing profile) were assessed using this model with and without pre-processing the stimuli by a hearing-aid algorithm. The influence of different settings of the algorithm on the impaired profile was investigated. To validate the model predictions, the effect of the algorithm on hearing profiles of human impaired listeners was measured. A computer model simulating impaired hearing (total absence of basilar membrane compression) was used, and three hearing-impaired listeners participated. The hearing profiles of the model and the listeners showed substantial changes when the test stimuli were pre-processed by the hearing-aid algorithm. These changes consisted of lower absolute thresholds, steeper temporal masking curves, and sharper psychophysical tuning curves. The hearing-aid algorithm affected the impaired hearing profile of the model to approximate a normal hearing profile. Qualitatively similar results were found with the impaired listeners' hearing profiles.
Example-Based Super-Resolution Fluorescence Microscopy.
Jia, Shu; Han, Boran; Kutz, J Nathan
2018-04-23
Capturing biological dynamics with high spatiotemporal resolution demands the advancement in imaging technologies. Super-resolution fluorescence microscopy offers spatial resolution surpassing the diffraction limit to resolve near-molecular-level details. While various strategies have been reported to improve the temporal resolution of super-resolution imaging, all super-resolution techniques are still fundamentally limited by the trade-off associated with the longer image acquisition time that is needed to achieve higher spatial information. Here, we demonstrated an example-based, computational method that aims to obtain super-resolution images using conventional imaging without increasing the imaging time. With a low-resolution image input, the method provides an estimate of its super-resolution image based on an example database that contains super- and low-resolution image pairs of biological structures of interest. The computational imaging of cellular microtubules agrees approximately with the experimental super-resolution STORM results. This new approach may offer potential improvements in temporal resolution for experimental super-resolution fluorescence microscopy and provide a new path for large-data aided biomedical imaging.
Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve
NASA Astrophysics Data System (ADS)
Hafizah Mokhtar, N.; Abas, Aizat
2018-05-01
In this work, two different designs of artificial heart valve were devised and then compared by considering the thrombosis, wear and valve orifice to anatomical orifice ratio of each mechanical heart valve. These different design configurations of bi-leaflet mechanical heart valves model are created through the use of Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. Design 1 is based on existing conventional bi-leaflet valve and design 2 based on modified bi-leaflet respectively. The flow pattern, velocity, vorticity and stress analysis have been done to justify the best design. Based on results, both of the designs show a Doppler velocity index of less than the allowable standard of 2.2 which is safe to be used as replacement of the human heart valve. However, design 2 shows that it has a lower possibility of cavitation issue which will lead to lower thrombosis and provide good central flow area of blood as compared to design 1.
Song, Seung-Joon; Choi, Jaesoon; Park, Yong-Doo; Lee, Jung-Joo; Hong, So Young; Sun, Kyung
2010-11-01
Bioprinting is an emerging technology for constructing tissue or bioartificial organs with complex three-dimensional (3D) structures. It provides high-precision spatial shape forming ability on a larger scale than conventional tissue engineering methods, and simultaneous multiple components composition ability. Bioprinting utilizes a computer-controlled 3D printer mechanism for 3D biological structure construction. To implement minimal pattern width in a hydrogel-based bioprinting system, a study on printing characteristics was performed by varying printer control parameters. The experimental results showed that printing pattern width depends on associated printer control parameters such as printing flow rate, nozzle diameter, and nozzle velocity. The system under development showed acceptable feasibility of potential use for accurate printing pattern implementation in tissue engineering applications and is another example of novel techniques for regenerative medicine based on computer-aided biofabrication system. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Implant alignment in total elbow arthroplasty: conventional vs. navigated techniques
NASA Astrophysics Data System (ADS)
McDonald, Colin P.; Johnson, James A.; King, Graham J. W.; Peters, Terry M.
2009-02-01
Incorrect selection of the native flexion-extension axis during implant alignment in elbow replacement surgery is likely a significant contributor to failure of the prosthesis. Computer and image-assisted surgery is emerging as a useful surgical tool in terms of improving the accuracy of orthopaedic procedures. This study evaluated the accuracy of implant alignment using an image-based navigation technique compared against a conventional non-navigated approach. Implant alignment error was 0.8 +/- 0.3 mm in translation and 1.1 +/- 0.4° in rotation for the navigated alignment, compared with 3.1 +/- 1.3 mm and 5.0 +/- 3.8° for the non-navigated alignment. Five (5) of the 11 non-navigated alignments were malaligned greater than 5° while none of the navigated alignments were placed with an error of greater than 2.0°. It is likely that improved implant positioning will lead to reduced implant loading and wear, resulting in fewer implantrelated complications and revision surgeries.
Program Aids Specification Of Multiple-Block Grids
NASA Technical Reports Server (NTRS)
Sorenson, R. L.; Mccann, K. M.
1993-01-01
3DPREP computer program aids specification of multiple-block computational grids. Highly interactive graphical preprocessing program designed for use on powerful graphical scientific computer workstation. Divided into three main parts, each corresponding to principal graphical-and-alphanumerical display. Relieves user of some burden of collecting and formatting many data needed to specify blocks and grids, and prepares input data for NASA's 3DGRAPE grid-generating computer program.