Deterministic Computer-Controlled Polishing Process for High-Energy X-Ray Optics
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
A deterministic computer-controlled polishing process for large X-ray mirror mandrels is presented. Using tool s influence function and material removal rate extracted from polishing experiments, design considerations of polishing laps and optimized operating parameters are discussed
NASA Technical Reports Server (NTRS)
Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.
NASA Astrophysics Data System (ADS)
Schinhaerl, Markus; Schneider, Florian; Rascher, Rolf; Vogt, Christian; Sperber, Peter
2010-10-01
Magnetorheological finishing is a typical commercial application of a computer-controlled polishing process in the manufacturing of precision optical surfaces. Precise knowledge of the material removal characteristic of the polishing tool (influence function) is essential for controlling the material removal on the workpiece surface by the dwell time method. Results from the testing series with magnetorheological finishing have shown that a deviation of only 5% between the actual material removal characteristic of the polishing tool and that represented by the influence function caused a considerable reduction in the polishing quality. The paper discusses reasons for inaccuracies in the influence function and the effects on the polishing quality. The generic results of this research serve for the development of improved polishing strategies, and may be used in alternative applications of computer-controlled polishing processes that quantify the material removal characteristic by influence functions.
Development of a Computer-Controlled Polishing Process for X-Ray Optics
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian
2009-01-01
The future X-ray observatory missions require grazing-incidence x-ray optics with angular resolution of < 5 arcsec half-power diameter. The achievable resolution depends ultimately on the quality of polished mandrels from which the shells are replicated. With an aim to fabricate better shells, and reduce the cost/time of mandrel production, a computer-controlled polishing machine is developed for deterministic and localized polishing of mandrels. Cylindrical polishing software is also developed that predicts the surface residual errors under a given set of operating parameters and lap configuration. Design considerations of the polishing lap are discussed and the effects of nonconformance of the lap and the mandrel are presented.
Center removal amount control of magnetorheological finishing process by spiral polishing way
NASA Astrophysics Data System (ADS)
Wang, Yajun; He, Jianguo; Ji, Fang; Huang, Wen; Xiao, Hong; Luo, Qing; Zheng, Yongcheng
2010-10-01
Spiral polishing is a traditional process of computer-controlled optical surfacing. However, the additional polishing amount is great and the center polishing amount is difficult to control. At first, a simplified mathematics model is presented for magnetorheological finishing, which indicates that the center polishing amount and additional polishing amount are proportional to the length and peak value of magnetorheological finishing influence function, and are inversely proportional to pitch and rotation rate of spiral track, and the center polishing amount is much bigger than average polishing amount. Secondly, the relationships of "tool feed way and center polishing amount", "spiral pitch and calculation accuracy of influence matrix for dwell time function solution", "spiral pitch and center polishing amount" and "peak removal rate, dimensions of removal function and center removal amount" are studied by numerical computation by Archimedes spiral path. It shows that the center polishing amount is much bigger in feed stage than that in backhaul stage when the head of influence function is towards workpiece edge in feeding; and the bigger pitch, the bigger calculation error of influence matrix elements; and the bigger pitch, the smaller center polishing amount, and the smaller peak removal rate and dimensions of removal function, the smaller center removal amount. At last, the polishing results are given, which indicates that the center polishing amount is acceptable with a suitable polishing amount rate of feed stage and backhaul stage, and with a suitable spiral pitch during magnetorheological finishing procedure by spiral motion way.
Computer numeric control subaperture aspheric surface polishing-microroughness evaluation
NASA Astrophysics Data System (ADS)
Prochaska, Frantisek; Polak, Jaroslav; Matousek, Ondrej; Tomka, David
2014-09-01
The aim of this work was an investigation of surface microroughness and shape accuracy achieved on an aspheric lens by subaperture computer numeric control (CNC) polishing. Different optical substrates were polished (OHARA S-LAH 58, SF4, ZERODUR) using a POLITEX™ polishing pad, synthetic pitch, and the natural optical pitch. Surface roughness was measured by light interferometer. The best results were achieved on the S-LAH58 glass and the ZERODUR™ using the natural optical pitch. In the case of SF4 glass, the natural optical pitch showed a tendency to scratch the surface. Experiments also indicated a problem in surface form deterioration when using the natural optical pitch, regardless of the type of optical material.
Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
The future X-ray observatory missions, such as International X-ray Observatory, require grazing incidence replicated optics of extremely large collecting area (3 m2) in combination with angular resolution of less than 5 arcsec half-power diameter. The resolution of a mirror shell depends ultimately on the quality of the cylindrical mandrels from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation studies have been performed to optimize the operational parameters as well as the polishing lap configuration. Furthermore, depending upon the surface error profile, a model for localized polishing based on dwell time approach is developed. Using the inputs from the mathematical model, a mandrel, having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. We report our first experimental results and discuss plans for further improvements in the polishing process.
Computer-Controlled Cylindrical Polishing Process for Large X-Ray Mirror Mandrels
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
We are developing high-energy grazing incidence shell optics for hard-x-ray telescopes. The resolution of a mirror shells depends on the quality of cylindrical mandrel from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation software is developed to model the residual surface figure errors of a mandrel due to the polishing process parameters and the tools used, as well as to compute the optical performance of the optics. The study carried out using the developed software was focused on establishing a relationship between the polishing process parameters and the mid-spatial-frequency error generation. The process parameters modeled are the speeds of the lap and the mandrel, the tool s influence function, the contour path (dwell) of the tools, their shape and the distribution of the tools on the polishing lap. Using the inputs from the mathematical model, a mandrel having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. The preliminary results of a series of polishing experiments demonstrate a qualitative agreement with the developed model. We report our first experimental results and discuss plans for further improvements in the polishing process. The ability to simulate the polishing process is critical to optimize the polishing process, improve the mandrel quality and significantly reduce the cost of mandrel production
Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian D.
2009-01-01
This paper establishes a relationship between the polishing process parameters and the generation of mid spatial-frequency error. The consideration of the polishing lap design to optimize the process in order to keep residual errors to a minimum and optimization of the process (speeds, stroke, etc.) and to keep the residual mid spatial-frequency error to a minimum, is also presented.
Optimization and application of influence function in abrasive jet polishing.
Li, Zhaoze; Li, Shengyi; Dai, Yifan; Peng, Xiaoqiang
2010-05-20
We analyze the material removal mechanism of abrasive jet polishing (AJP) technology, based on the fluid impact dynamics theory. Combined with the computational fluid dynamics simulation and process experiments, influence functions at different impingement angles are obtained, which are not of a regular Gaussian shape and are unfit for the corrective figuring of optics. The influence function is then optimized to obtain an ideal Gaussian shape by rotating the oblique nozzle, and its stability is validated through a line scanning experiment. The fluctuation of the influence function can be controlled within +/-5%. Based on this, we build a computed numerically controlled experimental system for AJP, and one flat BK7 optical glass with a diameter of 20mm is polished. After two iterations of polishing, the peak-to-valley value decreases from 1.43lambda (lambda=632.8nm in this paper) to 0.294lambda, and the rms value decreases from 0.195lambda to 0.029lambda. The roughness of this polished surface is within 2nm. The experimental result indicates that the optimized influence function is suitable for precision optics figuring and polishing.
Fischer, Nicholas G.; Wong, Jeffrey; Cerutis, D. Roselyn
2017-01-01
Mucosal seal formation around dental abutments is critical to the successful integration of dental implants into the human oral cavity. No information exists for how clinically relevant polishing procedures for computer-aided design and computer-aided manufactured (CAD/CAM) zirconia abutments affects cellular responses important to mucosal seal formation. CAD/CAM zirconia was divided into four groups for clinically relevant polishing utilizing commercial polishing heads: control, coarse, coarse plus medium, and coarse plus medium plus fine. Surfaces were analyzed with scanning electron microscopy (SEM), atomic force microscopy (AFM), and optical profilometry (OP). Subsequently, human gingival fibroblasts (HGFs) were seeded onto the zirconia surfaces. Proliferation was measured via a quantitative SEM technique and focal adhesion kinase (FAK) phosphorylation status was measured by an enzyme-linked immunosorbent assay (ELISA). Results showed an increase in proliferation on all polished surfaces as compared to the control. Phosphorylation of FAK at tyrosine 397 (Y397) was up-modulated on the control surfaces. The associated cell adaptation is discussed. In all cases, FAK phosphorylation was greater at 24 h than 48 h. These results suggest that clinicians should be mindful of the effects of abutment polishing methodology, as this may have an impact on early mucosal seal formation. PMID:29186907
Rigidity controllable polishing tool based on magnetorheological effect
NASA Astrophysics Data System (ADS)
Wang, Jia; Wan, Yongjian; Shi, Chunyan
2012-10-01
A stable and predictable material removal function (MRF) plays a crucial role in computer controlled optical surfacing (CCOS). For physical contact polishing case, the stability of MRF depends on intimate contact between polishing interface and workpiece. Rigid laps maintain this function in polishing spherical surfaces, whose curvature has no variation with the position on the surface. Such rigid laps provide smoothing effect for mid-spatial frequency errors, but can't be used in aspherical surfaces for they will destroy the surface figure. Flexible tools such as magnetorheological fluid or air bonnet conform to the surface [1]. They lack rigidity and provide little natural smoothing effect. We present a rigidity controllable polishing tool that uses a kind of magnetorheological elastomers (MRE) medium [2]. It provides the ability of both conforming to the aspheric surface and maintaining natural smoothing effect. What's more, its rigidity can be controlled by the magnetic field. This paper will present the design, analysis, and stiffness variation mechanism model of such polishing tool [3].
NASA Astrophysics Data System (ADS)
Huang, Wei-Ren; Huang, Shih-Pu; Tsai, Tsung-Yueh; Lin, Yi-Jyun; Yu, Zong-Ru; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Young, Hong-Tsu
2017-09-01
Spherical lenses lead to forming spherical aberration and reduced optical performance. Consequently, in practice optical system shall apply a combination of spherical lenses for aberration correction. Thus, the volume of the optical system increased. In modern optical systems, aspherical lenses have been widely used because of their high optical performance with less optical components. However, aspherical surfaces cannot be fabricated by traditional full aperture polishing process due to their varying curvature. Sub-aperture computer numerical control (CNC) polishing is adopted for aspherical surface fabrication in recent years. By using CNC polishing process, mid-spatial frequency (MSF) error is normally accompanied during this process. And the MSF surface texture of optics decreases the optical performance for high precision optical system, especially for short-wavelength applications. Based on a bonnet polishing CNC machine, this study focuses on the relationship between MSF surface texture and CNC polishing parameters, which include feed rate, head speed, track spacing and path direction. The power spectral density (PSD) analysis is used to judge the MSF level caused by those polishing parameters. The test results show that controlling the removal depth of single polishing path, through the feed rate, and without same direction polishing path for higher total removal depth can efficiently reduce the MSF error. To verify the optical polishing parameters, we divided a correction polishing process to several polishing runs with different direction polishing paths. Compare to one shot polishing run, multi-direction path polishing plan could produce better surface quality on the optics.
Computer numeric control generation of toric surfaces
NASA Astrophysics Data System (ADS)
Bradley, Norman D.; Ball, Gary A.; Keller, John R.
1994-05-01
Until recently, the manufacture of toric ophthalmic lenses relied largely upon expensive, manual techniques for generation and polishing. Recent gains in computer numeric control (CNC) technology and tooling enable lens designers to employ single- point diamond, fly-cutting methods in the production of torics. Fly-cutting methods continue to improve, significantly expanding lens design possibilities while lowering production costs. Advantages of CNC fly cutting include precise control of surface geometry, rapid production with high throughput, and high-quality lens surface finishes requiring minimal polishing. As accessibility and affordability increase within the ophthalmic market, torics promise to dramatically expand lens design choices available to consumers.
Forces acting between polishing tool and workpiece surface in magnetorheological finishing
NASA Astrophysics Data System (ADS)
Schinhaerl, Markus; Vogt, Christian; Geiss, Andreas; Stamp, Richard; Sperber, Peter; Smith, Lyndon; Smith, Gordon; Rascher, Rolf
2008-08-01
Magnetorheological finishing is a computer-controlled polishing technique that is used mainly in the field of high-quality optical lens production. The process is based on the use of a magnetorheological polishing fluid that is able, in a reversible manner, to change its viscosity from a liquid state to a solid state under the control of a magnetic field. This outstanding characteristic facilitates rapid control (in milliseconds) of the yield stress, and thus the pressure applied to the workpiece surface to be polished. A three-axis dynamometer was used to measure the forces acting between the magnetorheological fluid and the workpiece surface during determination of the material removal characteristic of the polishing tool (influence function). The results of a testing series using a QED Q22-X MRF polishing machine with a 50 mm wheel assembly show that the normal forces range from about 2 to 20 N. Knowledge of the forces is essential, especially when thin workpieces are to be polished and distortion becomes significant. This paper discusses, and gives examples of, the variation in the parameters experienced during a programme of experiments, and provides examples of the value of this work.
Effects of Polishing Bur Application Force and Reuse on Sintered Zirconia Surface Topography.
Fischer, N G; Tsujimoto, A; Baruth, A G
2018-03-16
Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.
NASA Technical Reports Server (NTRS)
Wright, G.; Bryan, J. B.
1986-01-01
Faster production of large optical mirrors may result from combining single-point diamond crushing of the glass with polishing using a small area tool to smooth the surface and remove the damaged layer. Diamond crushing allows a surface contour accurate to 0.5 microns to be generated, and the small area computer-controlled polishing tool allows the surface roughness to be removed without destroying the initial contour. Final contours with an accuracy of 0.04 microns have been achieved.
Investigation of contact pressure and influence function model for soft wheel polishing.
Rao, Zhimin; Guo, Bing; Zhao, Qingliang
2015-09-20
The tool influence function (TIF) is critical for calculating the dwell-time map to improve form accuracy. We present the TIF for the process of computer-controlled polishing with a soft polishing wheel. In this paper, the static TIF was developed based on the Preston equation. The pressure distribution was verified by the real removal spot section profiles. According to the experiment measurements, the pressure distribution simulated by Hertz contact theory was much larger than the real contact pressure. The simulated pressure distribution, which was modeled by the Winkler elastic foundation for a soft polishing wheel, matched the real contact pressure. A series of experiments was conducted to obtain the removal spot statistical properties for validating the relationship between material removal and processing time and contact pressure and relative velocity, along with calculating the fitted parameters to establish the TIF. The developed TIF predicted the removal character for the studied soft wheel polishing.
NASA Astrophysics Data System (ADS)
Bechtold, Michael; Mohring, David; Fess, Edward
2007-05-01
OptiPro Systems has developed a new finishing process for the manufacturing of precision optical components. UltraForm Finishing (UFF) has evolved from a tire shaped tool with polishing material on its periphery, to its newest design, which incorporates a precision rubber wheel wrapped with a band of polishing material passing over it. Through our research we have developed a user friendly graphical interface giving the optician a deterministic path for finishing precision optical components. Complex UFF Algorithms combine the removal function and desired depth of removal into a motion controlled tool path which minimizes surface roughness and form errors. The UFF process includes 5 axes of computer controlled motion, (3 linear and 2 rotary) which provide the flexibility for finishing a variety of shapes including spheres, aspheres, and freeform optics. The long arm extension, along with a range of diameters for the "UltraWheel" provides a unique solution for the finishing of steep concave shapes such as ogives and domes. The UltraForm process utilizes, fixed and loose abrasives, in combination with our proprietary "UltraBelts" made of a range of materials such as polyurethane, felt, resin, diamond and others.
Hoyo, Javier Del; Choi, Heejoo; Burge, James H; Kim, Geon-Hee; Kim, Dae Wook
2017-06-20
The control of surface errors as a function of spatial frequency is critical during the fabrication of modern optical systems. A large-scale surface figure error is controlled by a guided removal process, such as computer-controlled optical surfacing. Smaller-scale surface errors are controlled by polishing process parameters. Surface errors of only a few millimeters may degrade the performance of an optical system, causing background noise from scattered light and reducing imaging contrast for large optical systems. Conventionally, the microsurface roughness is often given by the root mean square at a high spatial frequency range, with errors within a 0.5×0.5 mm local surface map with 500×500 pixels. This surface specification is not adequate to fully describe the characteristics for advanced optical systems. The process for controlling and minimizing mid- to high-spatial frequency surface errors with periods of up to ∼2-3 mm was investigated for many optical fabrication conditions using the measured surface power spectral density (PSD) of a finished Zerodur optical surface. Then, the surface PSD was systematically related to various fabrication process parameters, such as the grinding methods, polishing interface materials, and polishing compounds. The retraceable experimental polishing conditions and processes used to produce an optimal optical surface PSD are presented.
Masks For Deposition Of Aspherical Optical Surfaces
NASA Technical Reports Server (NTRS)
Rogers, John R.; Martin, John D.
1992-01-01
Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.
The role of robotics in computer controlled polishing of large and small optics
NASA Astrophysics Data System (ADS)
Walker, David; Dunn, Christina; Yu, Guoyu; Bibby, Matt; Zheng, Xiao; Wu, Hsing Yu; Li, Hongyu; Lu, Chunlian
2015-08-01
Following formal acceptance by ESO of three 1.4m hexagonal off-axis prototype mirror segments, one circular segment, and certification of our optical test facility, we turn our attention to the challenge of segment mass-production. In this paper, we focus on the role of industrial robots, highlighting complementarity with Zeeko CNC polishing machines, and presenting results using robots to provide intermediate processing between CNC grinding and polishing. We also describe the marriage of robots and Zeeko machines to automate currently manual operations; steps towards our ultimate vision of fully autonomous manufacturing cells, with impact throughout the optical manufacturing community and beyond.
Rapid fabrication of a silicon modification layer on silicon carbide substrate.
Bai, Yang; Li, Longxiang; Xue, Donglin; Zhang, Xuejun
2016-08-01
We develop a kind of magnetorheological (MR) polishing fluid for the fabrication of a silicon modification layer on a silicon carbide substrate based on chemical theory and actual polishing requirements. The effect of abrasive concentration in MR polishing fluid on material removal rate and removal function shape is investigated. We conclude that material removal rate will increase and tends to peak value as the abrasive concentration increases to 0.3 vol. %, and the removal function profile will become steep, which is a disadvantage to surface frequency error removal at the same time. The removal function stability is also studied and the results show that the prepared MR polishing fluid can satisfy actual fabrication requirements. An aspheric reflective mirror of silicon carbide modified by silicon is well polished by combining magnetorheological finishing (MRF) using two types of MR polishing fluid and computer controlled optical surfacing (CCOS) processes. The surface accuracy root mean square (RMS) is improved from 0.087λ(λ=632.8 nm) initially to 0.020λ(λ=632.8 nm) in 5.5 h total and the tool marks resulting from MRF are negligible. The PSD analysis results also shows that the final surface is uniformly polished.
Removal of single point diamond-turning marks by abrasive jet polishing.
Li, Z Z; Wang, J M; Peng, X Q; Ho, L T; Yin, Z Q; Li, S Y; Cheung, C F
2011-06-01
Single point diamond turning (SPDT) is highly controllable and versatile in producing axially symmetric forms, non-axially-symmetric forms, microstructured surfaces, and free forms. However, the fine SPDT marks left in the surface limit its performance, and they are difficult to reduce or eliminate. It is unpractical for traditional methods to remove the fine marks without destroying their forms, especially for the aspheres and free forms. This paper introduces abrasive jet polishing (AJP) for the posttreatment of diamond-turned surfaces to remove the periodic microstructures. Samples of diamond-turned electroless nickel plated plano mirror were used in the experiments. One sample with an original surface roughness of more than 400 nm decreased to 4 nm after two iterations abrasive jet polishing; the surface roughness of another sample went from 3.7 nm to 1.4 nm after polishing. The periodic signatures on both of the samples were removed entirely after polishing. Contrastive experimental research was carried out on electroless nickel mirror with magnetorheological finishing, computer controlled optical surfacing, and AJP. The experimental results indicate that AJP is more appropriate in removing the periodic SPDT marks. Also, a figure maintaining experiment was carried out with the AJP process; the uniform polishing process shows that the AJP process can remove the periodic turning marks without destroying the original form.
1978-10-11
REQUIREMENTS OF COMPUTER USERS Warsaw INFORMATYKA in Polish Vol 12 No 8, 1977 pp 12-14 CHELCHOWSKI, JERZY, Academy of Economics, Wroclaw [Abstract...Western. 11 E. Hardware POLAND SQUARE-LOOP FERRITE CORES IN THE WORKING STORAGE OF MODERN COMPUTERS Warsaw INFORMATYKA in Polish Vol 12 No 5...INDUSTRY PLANT Warsaw INFORMATYKA in Polish Vol 12 No 10, 1977 Pp 20-22 BERNATOWICZ, KRYSTYN [Text] Next to mines, steelworks and shipyards, The H
Computer Controlled Optical Surfacing With Orbital Tool Motion
NASA Astrophysics Data System (ADS)
Jones, Robert A.
1985-10-01
Asymmetric aspheric optical surfaces are very difficult to fabricate using classical techniques and laps the same size as the workpiece. Opticians can produce such surfaces by grinding and polishing, using small laps with orbital tool motion. However, hand correction is a time consuming process unsuitable for large optical elements. Itek has developed Computer Controlled Optical Surfacing (CCOS) for fabricating such aspheric optics. Automated equipment moves a nonrotating orbiting tool slowly over the workpiece surface. The process corrects low frequency surface errors by figuring. The velocity of the tool assembly over the workpiece surface is purposely varied. Since the amount of material removal is proportional to the polishing or grinding time, accurate control over material removal is achieved. The removal of middle and high frequency surface errors is accomplished by pad smoothing. For a soft pad material, the pad will compress to fit the workpiece surface producing greater pressure and more removal at the surface high areas. A harder pad will ride on only the high regions resulting in removal only for those locations.
Automated Figuring and Polishing of Replication Mandrels for X-Ray Telescopes
NASA Technical Reports Server (NTRS)
Krebs, Carolyn (Technical Monitor); Content, David; Fleetwood, Charles; Wright, Geraldine; Arsenovic, Petar; Collela, David; Kolos, Linette
2003-01-01
In support of the Constellation X mission the Optics Branch at Goddard Space Flight Center is developing technology for precision figuring and polishing of mandrels used to produce replicated mirrors that will be used in X-Ray telescopes. Employing a specially built machine controlled in 2 axes by a computer, we are doing automated polishing/figuring of 15 cm long, 20 cm diameter cylindrical, conical and Wolter mandrels. A battery of tests allow us to fully characterize all important aspects of the mandrels, including surface figure and finish, mid-frequency errors, diameters and cone angle. Parts are currently being produced with surface roughnesses at the .5nm RMS level, and half-power diameter slope error less than 2 arcseconds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gniazdowski, J.
1995-12-31
JOHNSON CONTROLS manufactures measuring and control equipment (800 types) and is as well a {open_quotes}turn-key{close_quotes} supplier of complete automatic controls systems for heating, air conditioning, ventilation and refrigerating engineering branches. The Company also supplies Buildings` Computer-Based Supervision and Monitoring Systems that may be applied in both small and large structures. Since 1990 the company has been performing full-range trade and contracting activities on the Polish market. We have our own well-trained technical staff and we collaborate with a series of designing and contracting enterprises that enable us to have our projects carried out all over Poland. The prices of ourmore » supplies and services correspond with the level of the Polish market.« less
Du, Hang; Song, Ci; Li, Shengyi; Xu, Mingjin; Peng, Xiaoqiang
2017-05-20
In the process of computer controlled optical surfacing (CCOS), the uncontrollable rolled edge restricts further improvements of the machining accuracy and efficiency. Two reasons are responsible for the rolled edge problem during small tool polishing. One is that the edge areas cannot be processed because of the orbit movement. The other is that changing the tool influence function (TIF) is difficult to compensate for in algorithms, since pressure step appears in the local pressure distribution at the surface edge. In this paper, an acentric tool influence function (A-TIF) is designed to remove the rolled edge after CCOS polishing. The model of A-TIF is analyzed theoretically, and a control point translation dwell time algorithm is used to verify that the full aperture of the workpiece can be covered by the peak removal point of the tool influence functions. Thus, surface residual error in the full aperture can be effectively corrected. Finally, the experiments are carried out. Two fused silica glass samples of 100 mm×100 mm are polished by traditional CCOS and the A-TIF method, respectively. The rolled edge was clearly produced in the sample polished by the traditional CCOS, while residual errors do not show this problem the sample polished by the A-TIF method. Therefore, the rolled edge caused by the traditional CCOS process is successfully suppressed during the A-TIF process. The ability to suppress the rolled edge of the designed A-TIF has been confirmed.
Composite adaptive control of belt polishing force for aero-engine blade
NASA Astrophysics Data System (ADS)
Zhsao, Pengbing; Shi, Yaoyao
2013-09-01
The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and significantly reduces the surface roughness.
Edge effect modeling of small tool polishing in planetary movement
NASA Astrophysics Data System (ADS)
Li, Qi-xin; Ma, Zhen; Jiang, Bo; Yao, Yong-sheng
2018-03-01
As one of the most challenging problems in Computer Controlled Optical Surfacing (CCOS), the edge effect greatly affects the polishing accuracy and efficiency. CCOS rely on stable tool influence function (TIF), however, at the edge of the mirror surface,with the grinding head out of the mirror ,the contact area and pressure distribution changes, which resulting in a non-linear change of TIF, and leads to tilting or sagging at the edge of the mirror. In order reduce the adverse effects and improve the polishing accuracy and efficiency. In this paper, we used the finite element simulation to analyze the pressure distribution at the mirror edge and combined with the improved traditional method to establish a new model. The new method fully considered the non-uniformity of pressure distribution. After modeling the TIFs in different locations, the description and prediction of the edge effects are realized, which has a positive significance on the control and suppression of edge effects
NASA Astrophysics Data System (ADS)
Sugawara, Jun; Kamiya, Tomohiro; Mikashima, Bumpei
2017-09-01
Ultra-low thermal expansion ceramics NEXCERATM is regarded as one of potential candidate materials crucial for ultralightweight and thermally-stable optical mirrors for space telescopes which are used in future optical missions satisfying extremely high observation specifications. To realize the high precision NEXCERA mirrors for space telescopes, it is important to develop a deterministic aspheric shape polishing and a precise figure correction polishing method for the NEXCERA. Magnetorheological finishing (MRF) was tested to the NEXCERA aspheric mirror from best fit sphere shape, because the MRF technology is regarded as the best suited process for a precise figure correction of the ultralightweight mirror with thin sheet due to its advantage of low normal force polishing. As using the best combination of material and MR fluid, the MRF was performed high precision figure correction and to induce a hyperbolic shape from a conventionally polished 100mm diameter sphere, and achieved the sufficient high figure accuracy and the high quality surface roughness. In order to apply the NEXCERA to a large scale space mirror, for the next step, a middle size solid mirror, 250 mm diameter concave parabola, was machined. It was roughly ground in the parabolic shape, and was lapped and polished by a computer-controlled polishing machine using sub-aperture polishing tools. It resulted in the smooth surface of 0.6 nm RMS and the figure accuracy of λ/4, being enough as pre-MRF surface. A further study of the NEXCERA space mirrors should be proceeded as a figure correction using the MRF to lightweight mirror with thin mirror sheet.
Computer Controlled Optical Surfacing With Orbital Tool Motion
NASA Astrophysics Data System (ADS)
Jones, Robert A.
1985-11-01
Asymmetric aspheric optical surfaces are very difficult to fabricate using classical techniques and laps the same size as the workpiece. Opticians can produce such surfaces by hand grinding and polishing, using small laps with orbital tool motion. However, this is a time consuming process unsuitable for large optical elements.
Optimization of removal function in computer controlled optical surfacing
NASA Astrophysics Data System (ADS)
Chen, Xi; Guo, Peiji; Ren, Jianfeng
2010-10-01
The technical principle of computer controlled optical surfacing (CCOS) and the common method of optimizing removal function that is used in CCOS are introduced in this paper. A new optimizing method time-sharing synthesis of removal function is proposed to solve problems of the removal function being far away from Gaussian type and slow approaching of the removal function error that encountered in the mode of planet motion or translation-rotation. Detailed time-sharing synthesis of using six removal functions is discussed. For a given region on the workpiece, six positions are selected as the centers of the removal function; polishing tool controlled by the executive system of CCOS revolves around each centre to complete a cycle in proper order. The overall removal function obtained by the time-sharing process is the ratio of total material removal in six cycles to time duration of the six cycles, which depends on the arrangement and distribution of the six removal functions. Simulations on the synthesized overall removal functions under two different modes of motion, i.e., planet motion and translation-rotation are performed from which the optimized combination of tool parameters and distribution of time-sharing synthesis removal functions are obtained. The evaluation function when optimizing is determined by an approaching factor which is defined as the ratio of the material removal within the area of half of the polishing tool coverage from the polishing center to the total material removal within the full polishing tool coverage area. After optimization, it is found that the optimized removal function obtained by time-sharing synthesis is closer to the ideal Gaussian type removal function than those by the traditional methods. The time-sharing synthesis method of the removal function provides an efficient way to increase the convergence speed of the surface error in CCOS for the fabrication of aspheric optical surfaces, and to reduce the intermediate- and high-frequency error.
New method to control form and texture on industrially-sized lenses
NASA Astrophysics Data System (ADS)
Walker, D. D.
2003-05-01
Summary This paper provides a progress-report on the development of the Precessions polishing process. This is a new small-tool polishing technique for producing aspheric forms and correcting spherical forms. Precessions polishing has been developed by Zeeko Ltd in collaboration with the Optical Science Laboratory at University College London and Loh Optikmaschinen. The Zeeko/Loh All machine (see figure below) has a capacity of 200mm diameter, and is targeted at industrial lenses and mirrors. The baseline of the PrecessionsTM process is a sub-diameter physical tool working the surface with a polishing slurry. Position and orientation of the tooling is controlled by a 7-axis CNC polishing machine that has been custom-designed for the purpose. The tool comprises an inflated, bulged, rubber-membrane (the 'bonnet'), covered with one of the usual proprietary flexible polishing surfaces familiar to opticians. The membrane moulds itself around the local asphere, keeping good contact everywhere. It is spun about its axis to give high removal-rates, and attacks the surface of the part working on the side of the bulged surface, rather than the classical pole-down configuration. The contact area and polishing pressure can be varied independently by changing the degree to which the bonnet is compressed, and the internal fluid pressure. The rotation axis is precessed around the local normal to the part, and this averages surface texture and achieves a near-Gaussian tool removal-profile (Influence function'). For axially-symmetric parts, the part is rotated and the tool moved radially, thereby creating a spiral tool-path. An off- line software application analyses i) the surface error-profile, and ii) experimental data on the tool influence functions for different spot-sizes. An iterative numerical optimisation method is then used to compute the dwell-time and spot- size for each zone of the spiral on the surface, to rectify the form error.
Development of hybrid fluid jet/float polishing process
NASA Astrophysics Data System (ADS)
Beaucamp, Anthony T. H.; Namba, Yoshiharu; Freeman, Richard R.
2013-09-01
On one hand, the "float polishing" process consists of a tin lap having many concentric grooves, cut from a flat by single point diamond turning. This lap is rotated above a hydrostatic bearing spindle of high rigidity, damping and rotational accuracy. The optical surface thus floats above a thin layer of abrasive particles. But whilst surface texture can be smoothed to ~0.1nm rms (as measured by atomic force microscopy), this process can only be used on flat surfaces. On the other hand, the CNC "fluid jet polishing" process consists of pumping a mixture of water and abrasive particles to a converging nozzle, thus generating a polishing spot that can be moved along a tool path with tight track spacing. But whilst tool path feed can be moderated to ultra-precisely correct form error on freeform optical surfaces, surface finish improvement is generally limited to ~1.5nm rms (with fine abrasives). This paper reports on the development of a novel finishing method, that combines the advantages of "fluid jet polishing" (i.e. freeform corrective capability) with "float polishing" (i.e. super-smooth surface finish of 0.1nm rms or less). To come up with this new "hybrid" method, computational fluid dynamic modeling of both processes in COMSOL is being used to characterize abrasion conditions and adapt the process parameters of experimental fluid jet polishing equipment, including: (1) geometrical shape of nozzle, (2) position relative to the surface, (3) control of inlet pressure. This new process is aimed at finishing of next generation X-Ray / Gamma Ray focusing optics.
Recent achievements using chemical vapor composite silicon carbide (CVC SiC)
NASA Astrophysics Data System (ADS)
Goodman, William A.; Tanaka, Clifford
2009-08-01
This annual review documents our progress towards inexpensive mass production of silicon carbide mirrors and optical structures. Results are provided for a NASA Small Business Technology Transfer (STTR) X-Ray Mirror project. Trex partnered with the University of Alabama-Huntsville Center for Advanced Optics (UAH-CAO) to develop fabrication methods for polished cylindrical and conical chemical vapor composite (CVCTM) SiC mandrels. These mandrels are envisioned as pre-forms for the replication of fused silica x-ray optics to be eventually used in the International X-Ray Observatory (IXO). CVC SiCTM offers superior high temperature stability, thermal and mechanical performance and polishability required for this precision replication process. In this program, Trex fabricated prototype mandrels with design diameters of 10.5cm, 20cm and 45cm. UAH-CAO was Trex's university partner in this effort and worked on polishing and metrology of the unusual x-ray mandrel geometries. UAH-CAO successfully developed an innovative interferometric method for measuring the CVC SiCTM x-ray mandrels based on a precision cylindrical lens system. UAH-CAO also developed finishing and polishing methods for CVC SiCTM that utilized a Zeeko IRP200 computer controlled polishing tool. The three technologies key technologies demonstrated in this program (near net shape forming of CVC SiCTM mandrels, the x-ray mandrel metrology and free-form polishing capability on CVC SiCTM) could enable cost-effective manufacture of the x-ray mandrels required for the International X-Ray Observatory (IXO).
Dong, Zhichao; Cheng, Haobo; Tam, Hon-Yuen
2015-02-10
The velocity-varying regime used in deterministic subaperture polishing employs a time-invariant tool influence function (TIF) to figure localized surface errors by varying the transverse velocities of polishing tools. Desired transverse velocities have to be truncated if they exceed the maximal velocity of computer numerical control (CNC) machines, which induces excessive material removal and reduces figuring efficiency (FE). A time-variant (TV) TIF regime is presented, in which a TIF serves as a variable to compensate for excessive material removal when the transverse velocities are truncated. Compared with other methods, the TV-TIF regime exhibits better performance in terms of convergence rate, FE, and versatility; its operability can also be strengthened by a TIF library. Comparative experiments were conducted on a magnetorheological finishing machine to validate the effectiveness of the TV-TIF regime. Without a TV-TIF, the tool made an unwished dent (depth of 76 nm) at the center because of the velocity truncation problem. Through compensation with a TV-TIF, the dent was completely removed by the second figuring process, and a TV-TIF improved the FE from 0.029 to 0.066 mm(3)/h.
Dong, Zhichao; Cheng, Haobo; Tam, Hon-Yuen
2014-04-10
Numerical simulation of subaperture tool influence functions (TIF) is widely known as a critical procedure in computer-controlled optical surfacing. However, it may lack practicability in engineering because the emulation TIF (e-TIF) has some discrepancy with the practical TIF (p-TIF), and the removal rate could not be predicted by simulations. Prior to the polishing of a formal workpiece, opticians have to conduct TIF spot experiments on another sample to confirm the p-TIF with a quantitative removal rate, which is difficult and time-consuming for sequential polishing runs with different tools. This work is dedicated to applying these e-TIFs into practical engineering by making improvements from two aspects: (1) modifies the pressure distribution model of a flat-pitch polisher by finite element analysis and least square fitting methods to make the removal shape of e-TIFs closer to p-TIFs (less than 5% relative deviation validated by experiments); (2) predicts the removal rate of e-TIFs by reverse calculating the material removal volume of a pre-polishing run to the formal workpiece (relative deviations of peak and volume removal rate were validated to be less than 5%). This can omit TIF spot experiments for the particular flat-pitch tool employed and promote the direct usage of e-TIFs in the optimization of a dwell time map, which can largely save on cost and increase fabrication efficiency.
Dwell time algorithm based on the optimization theory for magnetorheological finishing
NASA Astrophysics Data System (ADS)
Zhang, Yunfei; Wang, Yang; Wang, Yajun; He, Jianguo; Ji, Fang; Huang, Wen
2010-10-01
Magnetorheological finishing (MRF) is an advanced polishing technique capable of rapidly converging to the required surface figure. This process can deterministically control the amount of the material removed by varying a time to dwell at each particular position on the workpiece surface. The dwell time algorithm is one of the most important key techniques of the MRF. A dwell time algorithm based on the1 matrix equation and optimization theory was presented in this paper. The conventional mathematical model of the dwell time was transferred to a matrix equation containing initial surface error, removal function and dwell time function. The dwell time to be calculated was just the solution to the large, sparse matrix equation. A new mathematical model of the dwell time based on the optimization theory was established, which aims to minimize the 2-norm or ∞-norm of the residual surface error. The solution meets almost all the requirements of precise computer numerical control (CNC) without any need for extra data processing, because this optimization model has taken some polishing condition as the constraints. Practical approaches to finding a minimal least-squares solution and a minimal maximum solution are also discussed in this paper. Simulations have shown that the proposed algorithm is numerically robust and reliable. With this algorithm an experiment has been performed on the MRF machine developed by ourselves. After 4.7 minutes' polishing, the figure error of a flat workpiece with a 50 mm diameter is improved by PV from 0.191λ(λ = 632.8 nm) to 0.087λ and RMS 0.041λ to 0.010λ. This algorithm can be constructed to polish workpieces of all shapes including flats, spheres, aspheres, and prisms, and it is capable of improving the polishing figures dramatically.
Approach for axisymmetrical asphere polishing with full-area tools
NASA Astrophysics Data System (ADS)
Novi, Andrea; Melozzi, Mauro
1999-09-01
Aspherics up to 500 nm diameter in optical glass or in ceramic substrates have been fabricated using area- compensated polishing tools and conventional optical shop machines. The tool forms are derived starting from the actual shape of the part under figuring. The figure error is measured using an interferometer mounted on-line with the polishing machine. Measurements are taken after each polishing step to compute the new tool form. The process speeds up the fabrication of aspheres and it improves repeatability in the manufacturing of axisymmetrical optics using moderate cost equipment's up to astronomical requirements. In the paper we present some examples of polishing results using the above mentioned approach on different aspherics for space applications.
Grazing Incidence Optics Technology
NASA Technical Reports Server (NTRS)
Ramsey, Brian; Smith, W. Scott; Gubarev, Mikhail; McCracken, Jeff
2015-01-01
This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.
Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.
Goo, C L; Yap, Auj; Tan, Kbc; Fawzy, A S
2016-01-01
This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone followed by Shofu zirconia polishing kit; Group 2 (SZ)-Shofu zirconia polishing kit; Group 3 (CE)-Ceramiste porcelain polishers; Group 4 (CM)-Ceramaster porcelain polishers; and Group 5 (KZ)-Komet ZR zirconia polishers. All specimens were ground with a fine-grit diamond bur prior to polishing procedures to simulate clinical finishing. Baseline and post-polishing profilometric readings were recorded and delta Ra values (difference in mean surface roughness before and after polishing) were computed and analyzed using one-way analysis of variance and Scheffe post hoc test (p<0.05). Representative scanning electron microscopy (SEM) images of the ground but unpolished and polished specimens were acquired. Delta Ra values ranged from 0.146 for CE to 0.400 for KZ. Delta Ra values for KZ, WZ, and SZ were significantly greater than for CE. Significant differences in delta Ra values were also observed between KZ and CM. The SEM images obtained were consistent with the profilometric findings. Diamond-impregnated polishing systems were more effective than silica carbide-impregnated ones in reducing the surface roughness of ground monolithic zirconia.
1977-08-24
exceeded a million rubles. POLAND SOME METHODOLOGICAL REMARKS RELATING TO THE FORECASTING MODEL OF COMPUTER DEVELOPMENT Warsaw INFORMATYKA in...PROCESSING SYSTEMS Warsaw INFORMATYKA in Polish Vol 11 No 10, Oct 76 pp 19-20 SEKULA, ZOFIA, Wroclaw [Abstract] The author presents critical remarks...TO ODRA 1300 SYSTEM Warsaw INFORMATYKA in Polish Vol 11 No 9, Sep 76 pp 1-4 BZDULA, CZESLAW, Research and Development Center of MERA-ELWRO Digital
Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David
2016-01-01
Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.
Neuroengineering control and regulation of behavior
NASA Astrophysics Data System (ADS)
Wróbel, A.; Radzewicz, C.; Mankiewicz, L.; Hottowy, P.; Knapska, E.; Konopka, W.; Kublik, E.; Radwańska, K.; Waleszczyk, W. J.; Wójcik, D. K.
2014-11-01
To monitor neuronal circuits involved in emotional modulation of sensory processing we proposed a plan to establish novel research techniques combining recent biological, technical and analytical discoveries. The project was granted by National Science Center and we started to build a new experimental model for studying the selected circuits of genetically marked and behaviorally activated neurons. To achieve this goal we will combine the pioneering, interdisciplinary expertise of four Polish institutions: (i) the Nencki Institute of Experimental Biology (Polish Academy of Sciences) will deliver the expertise on genetically modified mice and rats, mapping of the neuronal circuits activated by behavior, monitoring complex behaviors measured in the IntelliCage system, electrophysiological brain activity recordings by multielectrodes in behaving animals, analysis and modeling of behavioral and electrophysiological data; (ii) the AGH University of Science and Technology (Faculty of Physics and Applied Computer Sciences) will use its experience in high-throughput electronics to build multichannel systems for recording the brain activity of behaving animals; (iii) the University of Warsaw (Faculty of Physics) and (iv) the Center for Theoretical Physics (Polish Academy of Sciences) will construct optoelectronic device for remote control of opto-animals produced in the Nencki Institute based on the unique experience in laser sources, studies of light propagation and its interaction with condensed media, wireless medical robotic systems, fast readout opto-electronics with control software and micromechanics.
Chen, Shaoshan; Li, Shengyi; Peng, Xiaoqiang; Hu, Hao; Tie, Guipeng
2015-02-20
A new nonaqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing a KDP crystal. MRF polishing is easy to result in the embedding of carbonyl iron (CI) powders; meanwhile, Fe contamination on the KDP crystal surface will affect the laser induced damage threshold seriously. This paper puts forward an appropriate MRF polishing process to avoid the embedding. Polishing results show that the embedding of CI powders can be avoided by controlling the polishing parameters. Furthermore, on the KDP crystal surface, magnetorheological fluids residua inevitably exist after polishing and in which the Fe contamination cannot be removed completely by initial ultrasonic cleaning. To solve this problem, a kind of ion beam figuring (IBF) polishing is introduced to remove the impurity layer. Then the content of Fe element contamination and the depth of impurity elements are measured by time of flight secondary ion mass spectrometry. The measurement results show that there are no CI powders embedding in the MRF polished surface and no Fe contamination after the IBF polishing process, respectively. That verifies the feasibility of MRF polishing-IBF polishing (cleaning) for processing a KDP crystal.
Research on the magnetorheological finishing (MRF) technology with dual polishing heads
NASA Astrophysics Data System (ADS)
Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang
2014-08-01
Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.
Estimation of the dietary acrylamide exposure of the Polish population.
Mojska, Hanna; Gielecińska, Iwona; Szponar, Lucjan; Ołtarzewski, Maciej
2010-01-01
The objective of our study was to determine acrylamide content in the Polish foods and to assess the average dietary acrylamide exposure of the Polish population. We analysed the acrylamide content in Polish food using GCQ-MS/MS method. The daily dietary acrylamide exposure was computed using a probabilistic approach for the total Polish population (1-96 years) and for the following age groups: 1-6, 7-18 and 19-96, using Monte Carlo simulation technique. To assess the Polish population exposure to acrylamide present in food, food consumption data was taken from the 'Household Food Consumption and Anthropometric Survey in Poland'. The mean content of acrylamide in tested 225 samples of foodstuffs taken randomly all over Poland, ranged widely from 11 to 3647 microg/kg of product. For the total Polish population (1-96 years) the estimated acrylamide mean exposure is 0.43 microg/kg of body weight per day. The main sources of dietary acrylamide in Polish population were as follow: bread--supplied 45% of total dietary acrylamide intake, French fries and potato crisps--23%, roasted coffee--19%. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O
2013-12-01
AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.
ERIC Educational Resources Information Center
Kozaczka, Stanley J.
This essay outlines the development, present condition, and future direction of the 20,000-volume Polish research collection at Alliance College, located in Cambridge Springs, Pennsylvania. Alliance College was founded in 1912 by the Polish National Alliance (PNA), a life insurance fraternal organization. In 1931 its entire library collection was…
Development of TIF based figuring algorithm for deterministic pitch tool polishing
NASA Astrophysics Data System (ADS)
Yi, Hyun-Su; Kim, Sug-Whan; Yang, Ho-Soon; Lee, Yun-Woo
2007-12-01
Pitch is perhaps the oldest material used for optical polishing, leaving superior surface texture, and has been used widely in the optics shop floor. However, for its unpredictable controllability of removal characteristics, the pitch tool polishing has been rarely analysed quantitatively and many optics shops rely heavily on optician's "feel" even today. In order to bring a degree of process controllability to the pitch tool polishing, we added motorized tool motions to the conventional Draper type polishing machine and modelled the tool path in the absolute machine coordinate. We then produced a number of Tool Influence Function (TIF) both from an analytical model and a series of experimental polishing runs using the pitch tool. The theoretical TIFs agreed well with the experimental TIFs to the profile accuracy of 79 % in terms of its shape. The surface figuring algorithm was then developed in-house utilizing both theoretical and experimental TIFs. We are currently undertaking a series of trial figuring experiments to prove the performance of the polishing algorithm, and the early results indicate that the highly deterministic material removal control with the pitch tool can be achieved to a certain level of form error. The machine renovation, TIF theory and experimental confirmation, figuring simulation results are reported together with implications to deterministic polishing.
NASA Astrophysics Data System (ADS)
Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming
2018-03-01
In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.
Ahmad, Rohana; Morgano, Steven M; Wu, Benjamin M; Giordano, Russell A
2005-11-01
Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry. The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists. A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 x 2.0 x 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (alpha=.05). Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025). Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaffney, P.W.; Wooten, J.W.
1980-05-01
Four software tools PFORT, DAVE, POLISH, and BRNANL, which may be used to ensure the standardization of FORTRAN software are introduced. First, FORTRAN computer programs are loosely classified into three groups. Then reasons are given why the program in two of these groups should adhere to a portable subset of the American National Standard (ANS) First FORTRAN 1966. Next, the software tools PFORT, DAVE, POLISH, and BRNANL, are briefly described, and an example of the output from PFORT, DAVE, and POLISH are given. Finally, the dissemination of information pertaining to the tools together with their availability is outlined. 11 figures.
Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic.
Boaventura, Juliana Maria Capelozza; Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi
2013-01-01
To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0-S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) RESULTS: All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic.
Zerodur polishing process for high surface quality and high efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tesar, A.; Fuchs, B.
1992-08-01
Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of
Heimer, Sina; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna
2017-03-01
Polyetheretherketone (PEEK) can be used as a framework material for fixed dental prostheses. However, information about laboratory and chairside polishing methods is still scarce. The purpose of this in vitro study was to determine the effects of laboratory and chairside polishing methods on the surface roughness (SR) and surface free energy (SFE) of PEEK, an autopolymerizing poly(methyl methacrylate), and a veneering composite resin. For each of the 3 materials, 80 specimens were prepared (N=240) and divided into 7 polishing groups and 1 control group (n=10). The 7 groups were split into 4 laboratory protocols: polishing paste (Abraso), a second polishing paste (Opal L), silicone polisher (Ceragum), and diamond grinder (Diagen-Turbo grinder). The other 3 groups were chairside protocols: rainbow technique (Super-Snap kit), polishing paste (Prisma gloss), and a polishing system (Enhance finishing). Machine polishing with SiC P4000 served as the control treatment. The protocols' average SRs and SFEs were measured, and their surface topographies were evaluated with scanning electron microscopy (SEM). The logarithmically transformed data were analyzed using covariance analysis, 2-way and 1-way ANOVA, and partial correlation (α=.05). The polishing protocol exerted the highest influence on SR and SFE values (P<.001; SR: partial eta squared η P 2 =.970; SFE: η P 2 =.450), followed by material group (P<.001, SR: η P 2 =.319; SFE: η P 2 =.429). The interaction effect of the binary combinations of the 2 independent parameters (polishing protocol and material group) was also significant (P<.001, SR: η P 2 =.681; SFE: η P 2 =.365). Chairside methods presented lower SR values than laboratory methods, and specimens polished using the 2-body mode showed higher SR than did specimens polished using the 3-body mode. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Design and development of thin quartz glass WFXT polynomial mirror shells by direct polishing
NASA Astrophysics Data System (ADS)
Proserpio, L.; Campana, S.; Citterio, O.; Civitani, M.; Combrinck, H.; Conconi, P.; Cotroneo, V.; Freeman, R.; Langstrof, P.; Mattaini, E.; Morton, R.; Oberle, B.; Pareschi, G.; Parodi, G.; Pels, C.; Schenk, C.; Stock, R.; Tagliaferri, G.
2010-07-01
The Wide Field X-ray Telescope (WFXT) is a medium class mission for X-ray surveys of the sky with an unprecedented area and sensitivity. In order to meet the effective area requirement, the design of the optical system is based on very thin mirror shells, with thicknesses in the 1-2 mm range. In order to get the desired angular resolution (10 arcsec requirement, 5 arcsec goal) across the entire 1x1 degree FOV (Field Of View), the design of the optical system is based on nested modified grazing incidence Wolter-I mirrors realized with polynomial profiles, focal plane curvature and plate scale corrections. This design guarantees an increased angular resolution at large off-axis angle with respect to the normally used Wolter I configuration, making WFXT ideal for survey purposes. The WFXT X-ray Telescope Assembly is composed by three identical mirror modules of 78 nested shells each, with diameter up to 1.1 m. The epoxy replication process with SiC shells has already been proved to be a valuable technology to meet the angular resolution requirement of 10 arcsec. To further mature the telescope manufacturing technology and to achieve the goal of 5 arcsec, a deterministic direct polishing method is under investigation. The direct polishing method has already been used for past missions (as Einstein, Rosat, Chandra): the technological challenge now is to apply it for almost ten times thinner shells. Under investigation is quartz glass (fused silica), a well-known material with good thermo-mechanical and polishability characteristics that could meet our goal in terms of mass and stiffness, with significant cost and time saving with respect to SiC. Our approach is based on two main steps: first quartz glass tubes available on the market are grinded to conical profiles, and second the obtained shells are polished to the required polynomial profiles by CNC (Computer Numerical Control) polishing machine. In this paper, the first results of the direct grinding and polishing of prototypes shells made by quartz glass with low thickness, representative of the WFXT optical design, are presented.
NASA Astrophysics Data System (ADS)
Cardenas, Nelson; Kyrish, Matthew; Taylor, Daniel; Fraelich, Margaret; Lechuga, Oscar; Claytor, Richard; Claytor, Nelson
2015-03-01
Electro-Chemical Polishing is routinely used in the anodizing industry to achieve specular surface finishes of various metals products prior to anodizing. Electro-Chemical polishing functions by leveling the microscopic peaks and valleys of the substrate, thereby increasing specularity and reducing light scattering. The rate of attack is dependent of the physical characteristics (height, depth, and width) of the microscopic structures that constitute the surface finish. To prepare the sample, mechanical polishing such as buffing or grinding is typically required before etching. This type of mechanical polishing produces random microscopic structures at varying depths and widths, thus the electropolishing parameters are determined in an ad hoc basis. Alternatively, single point diamond turning offers excellent repeatability and highly specific control of substrate polishing parameters. While polishing, the diamond tool leaves behind an associated tool mark, which is related to the diamond tool geometry and machining parameters. Machine parameters such as tool cutting depth, speed and step over can be changed in situ, thus providing control of the spatial frequency of the microscopic structures characteristic of the surface topography of the substrate. By combining single point diamond turning with subsequent electro-chemical etching, ultra smooth polishing of both rotationally symmetric and free form mirrors and molds is possible. Additionally, machining parameters can be set to optimize post polishing for increased surface quality and reduced processing times. In this work, we present a study of substrate surface finish based on diamond turning tool mark spatial frequency with subsequent electro-chemical polishing.
Heintze, Siegward Dietmar; Forjanic, Monika
2008-10-01
To evaluate the effect of the multiple-use of a three-step rubber-based polishing system on the polishing performance with and without a disinfection/sterilization protocol with prolonged disinfection (overnight). The three-step polishing system Astropol was applied under standardized contact pressure of 2 N on 320 grit pre-roughened flat composite specimens of Tetric EvoCeram for 10 seconds (F and P disc) and 30 seconds (HP disc) respectively. After each polishing step, the surface gloss and roughness were measured with a glossmeter and an optical sensor (FRT MicroProf), respectively. Material loss of the composite specimens and polishing instruments were measured after each step with a high precision digital scale. For all four variables (surface gloss, surface roughness, composite loss, loss of rubber material) the mean percentage of change compared to the reference was calculated. Already after the first use, the instruments which were used without disinfection or sterilization demonstrated a statistically significantly reduced polishing performance in all polishing steps compared to the reference (new polishing system) (t-test, P < 0.05). In addition, this loss in performance further increased with the second and third re-use. Especially the third component (Astropol HP) was affected by performance loss. By contrast, the multiple-use of the instruments which were subjected to prolonged disinfection did not result in a reduced polishing performance. For the P disc, a statistically significant improvement of the polishing performance could be observed throughout almost all multiple-use sessions (ANOVA, P < 0.05). The improved polishing performance was, however, accompanied by an increased loss of the silicone rubber material of the P and F polishing discs; the HP discs were not affected by this loss. Furthermore, particles of the rubber material also adhered to the composite. The polishing performance of the discs which were only subjected to the sterilization process was not statistically significantly different to the polishing performance of the control group in terms of surface roughness; but the surface gloss was worse than that of the control group. No loss of rubber material or adherence to the composite was observed in this group.
Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic
Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi
2013-01-01
Objective. To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Materials and methods. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0–S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) Results. All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. Conclusions. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic. PMID:22724660
Novel cavitation fluid jet polishing process based on negative pressure effects.
Chen, Fengjun; Wang, Hui; Tang, Yu; Yin, Shaohui; Huang, Shuai; Zhang, Guanghua
2018-04-01
Traditional abrasive fluid jet polishing (FJP) is limited by its high-pressure equipment, unstable material removal rate, and applicability to ultra-smooth surfaces because of the evident air turbulence, fluid expansion, and a large polishing spot in high-pressure FJP. This paper presents a novel cavitation fluid jet polishing (CFJP) method and process based on FJP technology. It can implement high-efficiency polishing on small-scale surfaces in a low-pressure environment. CFJP uses the purposely designed polishing equipment with a sealed chamber, which can generate a cavitation effect in negative pressure environment. Moreover, the collapse of cavitation bubbles can spray out a high-energy microjet and shock wave to enhance the material removal. Its feasibility is verified through researching the flow behavior and the cavitation results of the negative pressure cavitation machining of pure water in reversing suction flow. The mechanism is analyzed through a computational fluid dynamics simulation. Thus, its cavitation and surface removal mechanisms in the vertical CFJP and inclined CFJP are studied. A series of polishing experiments on different materials and polishing parameters are conducted to validate its polishing performance compared with FJP. The maximum removal depth increases, and surface roughness gradually decreases with increasing negative outlet pressures. The surface becomes smooth with the increase of polishing time. The experimental results confirm that the CFJP process can realize a high material removal rate and smooth surface with low energy consumption in the low-pressure environment, together with compatible surface roughness to FJP. Copyright © 2017 Elsevier B.V. All rights reserved.
Flury, Simon; Diebold, Elisabeth; Peutzfeldt, Anne; Lussi, Adrian
2017-06-01
Because of the different composition of resin-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) materials, their polishability and their micromechanical properties vary. Moreover, depending on the composition of the materials, their surface roughness and micromechanical properties are likely to change with time. The purpose of this in vitro study was to investigate the effect of artificial toothbrushing and water storage on the surface roughness (Ra and Rz) and the micromechanical properties, surface hardness (Vickers [VHN]) and indentation modulus (E IT ), of 5 different tooth-colored CAD-CAM materials when polished with 2 different polishing systems. Specimens (n=40 per material) were cut from a composite resin (Paradigm MZ100; 3M ESPE), a feldspathic ceramic (Vitablocs Mark II; Vita Zahnfabrik), a resin nanoceramic (Lava Ultimate; 3M ESPE), a hybrid dental ceramic (Vita Enamic; Vita Zahnfabrik), and a nanocomposite resin (Ambarino High-Class; Creamed). All specimens were roughened in a standardized manner and polished either with Sof-Lex XT discs or the Vita Polishing Set Clinical. Surface roughness, VHN, and E IT were measured after polishing and after storage for 6 months (tap water, 37°C) with periodic, artificial toothbrushing. The surface roughness, VHN, and E IT results were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and exact Wilcoxon rank sum tests (α=.05). Irrespective of polishing system and of artificial toothbrushing and storage, Lava Ultimate generally showed the lowest surface roughness and Vitablocs Mark II the highest. As regards micromechanical properties, the following ranking of the CAD-CAM materials was found (from highest VHN/E IT to lowest VHN/E IT ): Vitablocs Mark II > Vita Enamic > Paradigm MZ100 > Lava Ultimate > Ambarino High-Class. Irrespective of material and of artificial toothbrushing and storage, polishing with Sof-Lex XT discs resulted in lower surface roughness than the Vita Polishing Set Clinical (P≤.016). However, the polishing system generally had no influence on the micromechanical properties (P>.05). The effect of artificial toothbrushing and storage on surface roughness depended on the material and the polishing system: Ambarino High-Class was most sensitive to storage, Lava Ultimate and Vita Enamic were least sensitive. Artificial toothbrushing and storage generally resulted in a decrease in VHN and E IT for Paradigm MZ100, Lava Ultimate, and Ambarino High-Class but not for Vita Enamic and Vitablocs Mark II. Tooth-colored CAD-CAM materials with lower VHN and E IT generally showed better polishability. However, these materials were more prone to degradation by artificial toothbrushing and water storage than materials with higher VHN and E IT . Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Engineering hurdles in contact and intraocular lens lathe design: the view ahead
NASA Astrophysics Data System (ADS)
Bradley, Norman D.; Keller, John R.; Ball, Gary A.
1994-05-01
Current trends in and intraocular lens design suggest ever- increasing demand for aspheric lens geometries - multisurface and/or toric surfaces - in a variety of new materials. As computer numeric controls (CNC) lathes and mills continue to evolve with he ophthalmic market, engineering hurdles present themselves to designers: Can hardware based upon single-point diamond turning accommodate the demands of software-driven designs? What are the limits of CNC resolution and repeatability in high-throughput production? What are the controlling factors in lathed, polish-free surface production? Emerging technologies in the lathed biomedical optics field are discussed along with their limitations, including refined diamond tooling, vibrational control, automation, and advanced motion control systems.
Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.
Camboni, Sara; Donnet, Marcel
2016-03-01
To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.
The pressure control technology of the active stressed lap
NASA Astrophysics Data System (ADS)
Li, Ying; Wang, Daxing
2010-10-01
The active stressed lap polishing technology is a kind of new polishing technology that can actively deform the lap surface to become an off-axis asphere according to different lap position on mirror surface and different angle of lap. The pressure of the lap on the mirror is an important factor affecting the grinding efficiency of the optics mirror. The active stressed lap technology using dynamic pressure control solution in the process of polishing astronomical Aspheric Mirror with faster asphericity will provide the advantage like high polishing speed and natural smooth, etc. This article puts emphases on the pressure control technology of the active stressed lap technology. It requires that the active stressed lap keeps symmetrical vertical compression on the mirrors in the process of grinding mirrors. With a background of an active stressed lap 450mm in diameter, this article gives an outline of the pressure control organization, analyzes the principle of pressure control and proposes the limitations of the present pressure control organization and the relevant solutions, designs a digital pressure controller with C32-bit RISC embedded and gives the relevant experimental test result finally.
The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases
Alammari, Manal Rahma
2017-01-01
Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objective The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. Methods This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. Results One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Conclusion Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability. PMID:29238483
The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.
Alammari, Manal Rahma
2017-10-01
Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 <0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.
Mohammadibassir, Mahshid; Rezvani, Mohammad Bagher; Golzari, Hossein; Moravej Salehi, Elham; Fahimi, Mohammad Amin; Kharazi Fard, Mohammad Javad
2017-03-08
To evaluate the effect of overglazing and two polishing procedures on flexural strength and quality and quantity of surface roughness of a monolithic lithium disilicate ceramic computer-aided design (CAD) after grinding. This in vitro study was conducted on 52 partially crystalized bar-shaped specimens (16 × 4 × 1.6 mm) of monolithic lithium disilicate ceramic. The specimens were wet polished with 600-, 800-, and 1200-grit silicon carbide papers for 15 seconds using a grinding/polishing machine at a speed of 300 rpm. Then, the specimens were crystalized and glaze-fired in one step simultaneously and randomly divided into four groups of 13: (I) Glazing group (control); (II) Grinding-glazing group, subjected to grinding with red band finishing diamond bur (46 μm) followed by glazing; (III) Grinding-D+Z group, subjected to grinding and then polishing by coarse, medium, and fine diamond rubber points (D+Z); and (IV) Grinding-OptraFine group, subjected to grinding and then polishing with a two-step diamond rubber polishing system followed by a final polishing step with an OptraFine HP brush and diamond polishing paste. The surface roughness (Ra and Rz) values (μm) were measured by a profilometer, and the mean values were compared using one-way ANOVA and Tamhane's test (post hoc comparison). One specimen of each group was evaluated under a scanning electron microscope (SEM) for surface topography. The three-point flexural strength values of the bars were measured using a universal testing machine at a 0.5 mm/min crosshead speed and recorded. The data were analyzed using one-way ANOVA and Tamhane's test (α = 0.05). Statistically significant differences were noted among the experimental groups for Ra, Rz (p < 0.0001), and flexural strength values (p < 0.009). The lowest Ra and Rz values were found in the grinding-OptraFine group (0.465 ± 0.153), which were significantly lower than those in glazing (p < 0.03) and grinding-glazing (p < 0.001) groups. The Ra and Rz values were not significantly different between the two polishing systems (p = 0.23 and p = 0.25, respectively). The highest flexural strength was found in the glazing group (283.350 ± 49.854 MPa) without significant differences compared to grinding-glazing (p = 0.98) and grinding-OptraFine groups (p = 0.86). The lowest flexural strength was found in grinding-D+Z group (225.070 ± 17.299), which was significantly different from the value in glazing (p < 0.03) and grinding-glazing (p < 0.04) groups. SEM analysis of polished surfaces revealed regular morphology with some striations. The OptraFine system created smoother and more uniform surfaces in terms of quantity (p < 0.03 for Ra, p < 0.01 for Rz) and quality of roughness compared to glazing. The flexural strength of lithium disilicate ceramic after polishing with the OptraFine system was similar to that after glazing (p = 0.86). Despite similar surface roughness after polishing with the two systems, the D+Z system reduced the flexural strength of ceramic (p < 0.03). © 2017 by the American College of Prosthodontists.
Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna
2015-01-01
Background: It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. Materials and Methods: 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: Control group: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Results: Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Conclusion: Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level. PMID:26229373
Yang, Hao; Cheng, Haobo; Feng, Yunpeng; Jing, Xiaoli
2018-05-01
Subaperture polishing techniques usually produce rolled edges due to edge effect. The rolled edges, especially those in millimeter scale on small components, are difficult to eliminate using conventional polishing methods. Magnetorheological jet polishing (MJP) offers the possibility of the removal of these structures, owing to its small tool influence function (TIF) size. Hence, we investigate the removal characters of inclined MJP jetting models by means of computational fluid dynamics (CFD) simulations and polishing experiments. A discrete phase model (DPM) is introduced in the simulation to get the influence of abrasive particle concentration on the removal mechanism. Therefore, a more accurate model for MJP removal mechanisms is built. With several critical problems solved, a small bevel-cut-like TIF (B-TIF), which has fine acentric and unimodal characteristics, is obtained through inclined jetting. The B-TIF proves to have little edge effect and is applied in surface polishing of thin rolled edges. Finally, the RMS of the experimental section profile converges from 10.5 nm to 1.4 nm, and the rolled edges are successfully suppressed. Consequently, it is validated that the B-TIF has remarkable ability in the removal of millimeter-scale rolled edges.
Wan, Songlin; Zhang, Xiangchao; He, Xiaoying; Xu, Min
2016-12-20
Computer controlled optical surfacing requires an accurate tool influence function (TIF) for reliable path planning and deterministic fabrication. Near the edge of the workpieces, the TIF has a nonlinear removal behavior, which will cause a severe edge-roll phenomenon. In the present paper, a new edge pressure model is developed based on the finite element analysis results. The model is represented as the product of a basic pressure function and a correcting function. The basic pressure distribution is calculated according to the surface shape of the polishing pad, and the correcting function is used to compensate the errors caused by the edge effect. Practical experimental results demonstrate that the new model can accurately predict the edge TIFs with different overhang ratios. The relative error of the new edge model can be reduced to 15%.
Interferometric analysis of polishing surface with a petal tool
NASA Astrophysics Data System (ADS)
Salas-Sánchez, Alfonso; Leal-Cabrera, Irce; Percino Zacarias, Elizabeth; Granados-Agustín, Fermín S.
2011-09-01
In this work, we describe a phase shift interferometric monitoring of polishing processes produced by a petal tool over a spherical surface to obtain a parabolic surface. In the process, we used a commercial polishing machine; the purpose of this work is to have control of polishing time. To achieve this analysis, we used a Fizeau interferometer of ZYGO Company for optical shop testing, and the Durango software from Diffraction International Company. For data acquisition, simulation and evaluation of optical surfaces, we start polishing process with a spherical surface with 15.46 cm of diameter; a 59.9 cm of radius curvature and, with f/# 1.9.
Sugiyama, Toshiko; Kameyama, Atsushi; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki
2017-06-01
This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words: CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness.
Sugiyama, Toshiko; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki
2017-01-01
Background This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). Material and Methods After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Results Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Conclusions Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words:CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness. PMID:28638554
Design and control of a macro-micro robot for precise force applications
NASA Technical Reports Server (NTRS)
Wang, Yulun; Mangaser, Amante; Laby, Keith; Jordan, Steve; Wilson, Jeff
1993-01-01
Creating a robot which can delicately interact with its environment has been the goal of much research. Primarily two difficulties have made this goal hard to attain. The execution of control strategies which enable precise force manipulations are difficult to implement in real time because such algorithms have been too computationally complex for available controllers. Also, a robot mechanism which can quickly and precisely execute a force command is difficult to design. Actuation joints must be sufficiently stiff, frictionless, and lightweight so that desired torques can be accurately applied. This paper describes a robotic system which is capable of delicate manipulations. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system. Delicate force tasks such as polishing, finishing, cleaning, and deburring, are the target applications of the robot.
Zhou, Jianying; Deng, Jiupeng; Li, Jinyuan; Wang, Jide; Shen, Baolian
2016-05-01
To evaluate the influence of different polishing methods on marginal microleakage of zirconium dioxide full crown. Thirty extracted premolars were selected and randomly divided into three groups, A, B and C, with 10 in each group. Group A was prepared with MANI TF-13 bur completely without the treatment of shoulder. The shoulder of group B was polished with MANI TR13-EF bur after the preparation using MANI TF-13. The shoulder of group C was polished with the dental pneumatic ultrasonic hand-piece of KaVo SONICflex after the preparation using MANI TF-13 bur. Five specimens after preparation were selected in each group. Fifteen CAD/CAM zirconium dioxide full crowns have been made. The crowns were bonded using PULPDENT resin cement, and the root canals were sealed using nail polish, and apical foramen were closed using flow resin. The test-pieces have been immersed in a 3% solution of methylene blue for 24 h. The condition of shoulder marginal microleakage was observed using light stereomicroscopy and evaluated in classification index. The remaining specimens in each group were used for roughness test and scanning electron microscope(SEM) experiment. The marginal microleakage situations of specimens in three groups was analyzed by SPSS 17.0. The enamel surface of different polishing methods was observed using SEM. The specimens in group C demonstrated the least marginal microleakage, and those in group B showed an intermediate level of marginal microleakage, and those in group A characterized the most serious marginal microleakage (total, χ2=44.610, P<0.01; among the different groups, P<0.05). The roughness experiment showed that specimens in group C achieve the smoothest results ([0.27±0.03] μm). Preparation shoulder polished using the dental pneumatic ultrasonic hand-piece demonstrated the best result under the SEM among the three groups. The anti-microleakage effectiveness of dental pneumatic ultrasonic hand-piece in shoulder refinement is better than ordinary shoulder treatment.
Trends in the use of the Internet for health purposes in Poland.
Bujnowska-Fedak, Maria Magdalena
2015-02-27
In Poland, like in other European countries and in accordance with the global trend, the number of computer users and people who have access to the Internet has increased considerably. The study investigates trends and patterns of Polish health-related Internet use over a period of seven years. The main objective of the study was to estimate the change in the proportion of the population using Internet for health purposes and to show the potential trend in perceptions and preferences of Polish citizens in this respect as well as factors affecting their use. The study was based on three national surveys that were conducted in 2005, 2007, and 2012. A total of 3027 adult citizens were selected randomly from the Polish population. A sample collection was carried out by Polish opinion poll agencies by computer-assisted telephone interviews. The subjects were asked to respond to general questions about their Internet use and their Internet use for health-related purposes, as well as to express their opinions about various sources of medical information, frequency, and the need for direct communication with health professionals via the Internet and other interactive forms of online activities. The proportion of the Polish population that used the Internet for health-related purposes increased significantly (41.7% in 2005, 53.3% in 2007, and 66.7% in 2012). The Internet has become an important source of health information for almost half of Polish citizens, overtaking television, radio, press, and courses or lectures in the ranking list. As the medium matures, the use of interactive, health-related online services has also increased remarkably. However, while the main users of the Internet are certainly younger people, the largest growth potential has been observed among the elderly. The profile of the most likely Internet user and the citizen for whom the Internet is an important source of health information has been determined. The Internet offers enormous opportunities, particularly for providing and improving consumer information services with regard to health care. A sharply increasing trend regarding Internet use, Internet use for health purposes, and the interactive use of the Internet related to health has been observed among Polish citizens.
Chowdhary, Zoya; Mohan, Ranjana
2018-01-01
Tooth polishing is an integral part of clinical dentistry. The main purpose of polishing is to smoothen the surface of the tooth and minimize the deposition of plaque to allow a healthy periodontal maintenance postscaling. Today, polishing by different methods is available to a clinician. Traditional bristle brush and rubber-cup polishing are being widely practiced and gradually getting replaced by novel air polisher. Pros and cons of each method should be weighed before its clinical applications. To evaluate and compare the efficiency of three different polishing systems on enamel as well as on cementum surfaces by scanning electron microscope (SEM). A total of 120 samples were divided into three groups randomly - Group 1 (bristle brush), Group 2 (rubber cup), and Group 3 (air polisher) - with 20 samples each of enamel and cementum, which were subdivided into 10 control and 10 test group (subjected to polishing). The samples were analyzed by SEM at ×1000 magnification, and the data obtained were compiled and subjected to statistical analysis. Polishing with bristle brush demonstrated less surface roughness and debris when compared to air polisher at P = 0.58, P = 0.03 for enamel surface and P = 0.003, P = 0.21 for cementum, respectively. The surface roughness was reduced considerably by rubber cup at P = 0.03 for enamel and P = 0.003 for cementum, compared to air polisher at P = 0.99 and P = 0.21 for enamel and cementum, respectively. The results indicate that polishing with rubber cup was more effective and statistically significant when compared to bristle brush polishing and air polisher for the crown and root surface smoothening and debris removal.
NASA Astrophysics Data System (ADS)
Nie, Xuqing; Li, Shengyi; Song, Ci; Hu, Hao
2014-08-01
Due to the different curvature everywhere, the aspheric surface is hard to achieve high-precision accuracy by the traditional polishing process. Controlling of the mid-spatial frequency errors (MSFR), in particular, is almost unapproachable. In this paper, the combined fabrication process based on the smoothing polishing (SP) and magnetorheological finishing (MRF) is proposed. The pressure distribution of the rigid polishing lap and semi-flexible polishing lap is calculated. The shape preserving capacity and smoothing effect are compared. The feasibility of smoothing aspheric surface with the semi-flexible polishing lap is verified, and the key technologies in the SP process are discussed. Then, A K4 parabolic surface with the diameter of 500mm is fabricated based on the combined fabrication process. A Φ150 mm semi-flexible lap is used in the SP process to control the MSFR, and the deterministic MRF process is applied to figure the surface error. The root mean square (RMS) error of the aspheric surface converges from 0.083λ (λ=632.8 nm) to 0.008λ. The power spectral density (PSD) result shows that the MSFR are well restrained while the surface error has a great convergence.
NASA Astrophysics Data System (ADS)
Pareschi, G.; Campana, S.
The Wide Field X-ray Telescope (WFXT) is a medium class mission for X-ray surveys of the sky with an unprecedented area and sensitivity. In order to meet the effective area requirement, the design of the optical system is based on very thin mirror shells, with thicknesses in the 1-2 mm range. In order to get the desired angular resolution (10 arcsec requirement, 5 arcsec goal) across the entire 1× 1 degree FOV (Field Of View), the design of the optical system is based on nested modified grazing incidence Wolter-I mirrors realized with polynomial profiles, focal plane curvature and plate scale corrections. This design guarantees an increased angular resolution at large off-axis angle with respect to the normally used Wolter I configuration, making WFXT ideal for survey purposes. The WFXT X-ray Telescope Assembly is composed by three identical mirror modules of 78 nested shells each, with diameter up to 1.1 m. The epoxy replication process with SiC shells has already been proved to be a valuable technology to meet the angular resolution requirement of 10 arcsec. To further mature the telescope manufacturing technology and to achieve the goal of 5 arcsec, we are considering different materials for the mirror shells with particular care to quartz glass (fused silica), a well-known material with good thermo-mechanical and polishability characteristics that could meet our goal in terms of mass and stiffness, with significant cost and time saving with respect to SiC. To bring the mirror shells to the needed accuracy a deterministic direct polishing method for the mirror shells is under investigation. A direct polishing method has already been used for past missions (as Einstein, Rosat, Chandra): the technological challenge now is to apply it for almost ten times thinner shells. Our approach is based on two main steps: first quartz glass tubes available on the market are grinded to conical profiles, and second the obtained shells are polished to the required polynomial profiles by Computer Numerical Control (CNC) polishing machine.
Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna
2015-07-01
It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level.
A macro-micro robot for precise force applications
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Wang, Yulun
1993-01-01
This paper describes an 8 degree-of-freedom macro-micro robot capable of performing tasks which require accurate force control. Applications such as polishing, finishing, grinding, deburring, and cleaning are a few examples of tasks which need this capability. Currently these tasks are either performed manually or with dedicated machinery because of the lack of a flexible and cost effective tool, such as a programmable force-controlled robot. The basic design and control of the macro-micro robot is described in this paper. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system.
Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R
2015-12-01
To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.
Syrkiewicz-S Witała, Magdalena; Romaniuk, Piotr; Strzelecka, Agnieszka; Lar, Katarzyna; Holecki, Tomasz
2018-01-01
To investigate whether the Polish Marshal Offices use instruments for social media marketing activities in the field of health promotion. 14 Polish Marshal Offices participated. The Computer-Assisted Web Interview and Computer-Assisted Telephone Interview were used along with a proprietary questionnaire. Standard statistical methods were employed. The number of people using the Internet and social media in Poland is steadily growing. The majority of the offices (93%) performed health promotion activities. The authorities collaborated with other units of local government and non-governmental organizations in these activities. According to respondents, the most convincing form of health promotion is direct communication (46%). More than half of the surveyed offices (56%) did not use portals or social networking sites in health campaigns. The rest of the offices indicated using Facebook (25%) or YouTube (6%). Half of them did not apply the tools of social media marketing. The other half was involved in discussions on health-related online forums (moderation or consulting). Relatively few offices use social media and social media marketing in health promotion campaigns. The use of social media by the Marshal Offices may result in a potential increase in effectiveness of the pro-health campaigns. It is recommended that Polish Marshal Offices recognize the potential benefits of social media marketing campaign instruments in the field of health promotion in order to reach out the digital recipients.
Intelligent Manufacturing of Commercial Optics Final Report CRADA No. TC-0313-92
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, J. S.; Pollicove, H.
The project combined the research and development efforts of LLNL and the University of Rochester Center for Manufacturing Optics (COM), to develop a new generation of flexible computer controlled optics· grinding machines. COM's principal near term development effort is to commercialize the OPTICAM-SM, a new prototype spherical grinding machine. A crucial requirement for commercializing the OPTICAM-SM is the development of a predictable and repeatable material removal process ( deterministic micro-grinding) that yields high quality surfaces that minimize non-deterministic polishing. OPTICAM machine tools and the fabrication process development studies are part of COM' s response to the DOD (ARPA) request tomore » implement a modernization strategy for revitalizing the U.S. optics manufacturing base. This project was entered into in order to develop a new generation of :flexible, computer-controlled optics grinding machines.« less
Influence of surface finishing on fracture load and failure mode of glass ceramic crowns.
Mores, Rafael Tagliari; Borba, Márcia; Corazza, Pedro Henrique; Della Bona, Álvaro; Benetti, Paula
2017-10-01
Ceramic restorations often require adjustments using diamond rotary instruments, which damage the glazed surface. The effect of these adjustments on the fracture behavior of these restorations is unclear. The purpose of this in vitro study was to evaluate the influence of induced surface defects on the fracture load and mode of failure of lithium disilicate-based (LDS) glass ceramic restorations. Premolar crowns were obtained from LDS computer-aided design and computer-aided manufacturing blocks (n=60) and glazed. The crowns were bonded to dentin analog dies and divided into 5 groups (n=12), as follows: glaze; abrasion (diamond rotary instrument 2135); abrasion and reglaze; abrasion and polishing (diamond rotary instrument 2135F, 2135 FF, and polishing devices); and polishing. The topography of the crowns was examined by scanning electron microscopy, and roughness was measured. A compressive load (0.5 mm/min) was applied by a piston to the center of the lingual cusp until fracture. The fracture load was recorded and data were statistically analyzed by ANOVA and the Tukey HSD test (α=.05). Fractured crowns were examined to determine the fracture origin. Polishing and/or reglazing resulted in lower roughness than for the abraded group (P<.05), which did not affect the fracture loads (P=.696). Catastrophic fracture with origin at the intaglio surface was the mode of failure for all the crowns. The experiment design successfully submitted the crowns to a clinical stress state, resulting in a clinically relevant failure. Reglazing or polishing were effective in reducing surface defects. Surface treatments had no effect on the immediate catastrophic failure of LDS crowns. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Natesh, R.; Smith, J. M.; Bruce, T.; Oidwai, H. A.
1980-01-01
One hundred and seventy four silicon sheet samples were analyzed for twin boundary density, dislocation pit density, and grain boundary length. Procedures were developed for the quantitative analysis of the twin boundary and dislocation pit densities using a QTM-720 Quantitative Image Analyzing system. The QTM-720 system was upgraded with the addition of a PDP 11/03 mini-computer with dual floppy disc drive, a digital equipment writer high speed printer, and a field-image feature interface module. Three versions of a computer program that controls the data acquisition and analysis on the QTM-720 were written. Procedures for the chemical polishing and etching were also developed.
Microwave Photonics Systems Based on Whispering-gallery-mode Resonators
Coillet, Aurélien; Henriet, Rémi; Phan Huy, Kien; Jacquot, Maxime; Furfaro, Luca; Balakireva, Irina; Larger, Laurent; Chembo, Yanne K.
2013-01-01
Microwave photonics systems rely fundamentally on the interaction between microwave and optical signals. These systems are extremely promising for various areas of technology and applied science, such as aerospace and communication engineering, sensing, metrology, nonlinear photonics, and quantum optics. In this article, we present the principal techniques used in our lab to build microwave photonics systems based on ultra-high Q whispering gallery mode resonators. First detailed in this article is the protocol for resonator polishing, which is based on a grind-and-polish technique close to the ones used to polish optical components such as lenses or telescope mirrors. Then, a white light interferometric profilometer measures surface roughness, which is a key parameter to characterize the quality of the polishing. In order to launch light in the resonator, a tapered silica fiber with diameter in the micrometer range is used. To reach such small diameters, we adopt the "flame-brushing" technique, using simultaneously computer-controlled motors to pull the fiber apart, and a blowtorch to heat the fiber area to be tapered. The resonator and the tapered fiber are later approached to one another to visualize the resonance signal of the whispering gallery modes using a wavelength-scanning laser. By increasing the optical power in the resonator, nonlinear phenomena are triggered until the formation of a Kerr optical frequency comb is observed with a spectrum made of equidistant spectral lines. These Kerr comb spectra have exceptional characteristics that are suitable for several applications in science and technology. We consider the application related to ultra-stable microwave frequency synthesis and demonstrate the generation of a Kerr comb with GHz intermodal frequency. PMID:23963358
Microwave photonics systems based on whispering-gallery-mode resonators.
Coillet, Aurélien; Henriet, Rémi; Phan Huy, Kien; Jacquot, Maxime; Furfaro, Luca; Balakireva, Irina; Larger, Laurent; Chembo, Yanne K
2013-08-05
Microwave photonics systems rely fundamentally on the interaction between microwave and optical signals. These systems are extremely promising for various areas of technology and applied science, such as aerospace and communication engineering, sensing, metrology, nonlinear photonics, and quantum optics. In this article, we present the principal techniques used in our lab to build microwave photonics systems based on ultra-high Q whispering gallery mode resonators. First detailed in this article is the protocol for resonator polishing, which is based on a grind-and-polish technique close to the ones used to polish optical components such as lenses or telescope mirrors. Then, a white light interferometric profilometer measures surface roughness, which is a key parameter to characterize the quality of the polishing. In order to launch light in the resonator, a tapered silica fiber with diameter in the micrometer range is used. To reach such small diameters, we adopt the "flame-brushing" technique, using simultaneously computer-controlled motors to pull the fiber apart, and a blowtorch to heat the fiber area to be tapered. The resonator and the tapered fiber are later approached to one another to visualize the resonance signal of the whispering gallery modes using a wavelength-scanning laser. By increasing the optical power in the resonator, nonlinear phenomena are triggered until the formation of a Kerr optical frequency comb is observed with a spectrum made of equidistant spectral lines. These Kerr comb spectra have exceptional characteristics that are suitable for several applications in science and technology. We consider the application related to ultra-stable microwave frequency synthesis and demonstrate the generation of a Kerr comb with GHz intermodal frequency.
Tsarev, V N; Ippolitov, E V; Trefilov, A G; Arutiunov, S D; Pivovarov, A A
2014-01-01
Study the main surface parameters of milled polyacrylic materials using atomic force microscopy and primary microbial adhesion of periodontopathogenic group bacteria and Candida albicans fungi taking into consideration the method of sample polishing. Studied samples: mill-treated without polishing (control); ergobox polished; polished in dental laboratory conditions; polished by a rubber brush in dentists' office. Microbial strains belonging to periodontopathogenic species (clinical isolates) that had been isolated from periodontal pockets of periodontitis patients: Porphyromonas gingivalis, Fusobacterium nucleatum, Streptococcus sanguis, C. albicans fungi were used for modelling experiments of primary adhesion of microbes to the material samples. S. sanguis had the highest degree of adhesion to polymer after milling, P. gingivalis, C. albicans--medium, F. nucleatum--low. A significant reduction of adhesion is observed during polishing in dental laboratory conditions or ergobox, less significant--during polishing in dental office. The data obtained allow to make a conclusion that the samples from polymer materials for preparation of prosthesis basis have varying degree of intensity of microbial adhesion of members of periodontopathogenic microflora and C. albicans fungi that depends on the polishing method, that accordingly determined the differences in colonization resistance against formation of microbial biofilm during polymer use in clinical conditions. . ,
Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass
Suratwala, Tayyab; Steele, William; Wong, Lana; ...
2015-05-19
The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increasedmore » with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.« less
Complete wavefront and polarization control for ultrashort-pulse laser microprocessing.
Allegre, O J; Jin, Y; Perrie, W; Ouyang, J; Fearon, E; Edwardson, S P; Dearden, G
2013-09-09
We report on new developments in wavefront and polarization control for ultrashort-pulse laser microprocessing. We use two Spatial Light Modulators in combination to structure the optical fields of a picosecond-pulse laser beam, producing vortex wavefronts and radial or azimuthal polarization states. We also carry out the first demonstration of multiple first-order beams with vortex wavefronts and radial or azimuthal polarization states, produced using Computer Generated Holograms. The beams produced are used to nano-structure a highly polished metal surface. Laser Induced Periodic Surface Structures are observed and used to directly verify the state of polarization in the focal plane and help to characterize the optical properties of the setup.
Nasoohi, Negin; Hoorizad, Maryam
2017-01-01
Objectives: This study aimed to assess the effect of wet and dry finishing and polishing on microhardness and roughness of microhybrid and nanohybrid composites. Materials and Methods: Thirty samples were fabricated of each of the Polofil Supra and Aelite Aesthetic All-Purpose Body microhybrid and Grandio and Aelite Aesthetic Enamel nanohybrid composite resins. Each group (n=30) was divided into three subgroups of D, W and C (n=10). Finishing and polishing were performed dry in group D and under water coolant in group W. Group C served as the control group and did not receive finishing and polishing. Surface roughness of samples was measured by a profilometer and their hardness was measured by a Vickers hardness tester. Data were analyzed using two-way ANOVA (P<0.05). Results: The smoothest surfaces with the lowest microhardness were obtained under Mylar strip without finishing/polishing for all composites (P<0.0001). The highest surface roughness was recorded for dry finishing/polishing for all composites (P<0.0001). Dry finishing/polishing increased the microhardness of all composites (P<0.0001). Conclusions: Dry finishing and polishing increases the microhardness and surface roughness of microhybrid and nanohybrid composite resins. PMID:29104597
New perspectives in hydrodynamic radial polishing techniques for optical surfaces
NASA Astrophysics Data System (ADS)
Ruiz, Elfego; Sohn, Erika; Luna, Esteban; Salas, Luis; Cordero, Alberto; González, Jorge; Núñez, Manuel; Salinas, Javier; Cruz-González, Irene; Valdés, Jorge; Cabrera, Victor; Martínez, Benjamín
2004-09-01
In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.
Polish Teenage Students' Willingness to Engage in On-Line Intercultural Interactions
ERIC Educational Resources Information Center
Wach, Aleksandra
2013-01-01
Computer-based technologies, including various forms of computer-mediated communication (CMC), provide L2 users with opportunities to engage in intercultural interactions which may promote the development of their intercultural communicative competence. The article reports the findings of a study that investigated how beyond-the-classroom…
Zanatta, Fabricio Batistin; Pinto, Tatiana Militz; Kantorski, Karla Zanini; Rösing, Cassiano Kuchenbecker
2011-01-01
The aim of this study was to compare the effect of polishing after scaling and root planing on supragingival plaque, calculus formation, and gingival bleeding. The study was designed as a split-mouth randomised clinical trial. Seventy-six patients were submitted to supragingival scaling on the six mandibular anterior teeth with manual curettes until a smooth surface was achieved. Subsequently, quadrants were randomly selected to be polished (test) or not (control) with a rubber cup and pumice. One, two and three weeks following treatment, a blinded examiner evaluated the visible plaque index, gingival bleeding index and the presence of supragingival calculus on the lingual tooth surfaces. The results showed that unpolished surfaces exhibited higher mean percentages of visible plaque in the third week. No statistically significant differences were observed between unpolished and polished sites related to gingival bleeding. Calculus formation was higher on unpolished sites than on polished sites at 2 and 3 weeks. Dental polishing after supragingival scaling contributed to reducing plaque and calculus formation. Polishing exerts an inhibitory effect on plaque and calculus formation.
Yazici, A Ruya; Tuncer, Duygu; Antonson, Sibel; Onen, Alev; Kilinc, Evren
2010-01-01
The aim of this study was to investigate the effect of delayed finishing/polishing on the surface roughness, hardness and gloss of tooth-coloured restorative materials. Four different tooth-coloured restoratives: a flowable resin composite- Tetric Flow, a hybrid resin composite- Venus, a nanohybrid resin composite- Grandio, and a polyacid modified resin composite- Dyract Extra were used. 30 specimens were made for each material and randomly assigned into three groups. The first group was finished/polished immediately and the second group was finished/polished after 24 hours. The remaining 10 specimens served as control. The surface roughness of each sample was recorded using a laser profilometer. Gloss measurements were performed using a small-area glossmeter. Vickers microhardness measurements were performed from three locations on each specimen surface under 100g load and 10s dwell time. Data for surface roughness and hardness were analyzed by Kruskal Wallis test and data for gloss were subjected to one-way ANOVA and Tukey test (P <.05). The smoothest surfaces were obtained under Mylar strip for all materials. While there were no significant differences in surface roughness of immediate and delayed finished/polished Dyract Extra samples, immediately finished/polished Venus and Grandio samples showed significantly higher roughness than the delayed polished samples (P <.05). In Tetric Flow samples, immediately finishing/polishing provided smoother surface than delayed finishing/polishing (P <.05). The highest gloss values were recorded under Mylar strip for all materials. While delayed finishing/polishing resulted in a significantly higher gloss compared to immediate finishing/polishing in Venus samples (P <.05), no differences were observed between delayed or immediate finishing/polishing for the other materials (P>.05). The lowest hardness values were found under Mylar strip. Delayed finishing/polishing significantly increased the hardness of all materials. The effect of delayed finishing/polishing on surface roughness, gloss and hardness appears to be material dependent.
Szpakowski, Rafał; Zając, Patrycja W; Dykowska, Grażyna; Sienkiewicz, Zofia; Augustynowicz, Anna; Czerw, Aleksandra
2016-06-30
According to data from the Organisation for Economic Cooperation and Development, Poland has one of the lowest numbers of nurses (5.2) per 1000 inhabitants among 28 EU countries. The migration of nurses from Poland has particular importance in the context of scarce human resources in this professional group, especially given the increasingly ageing population in European societies, which will entail an increased demand for nursing and care services. The aim of the study was to obtain information on the intentions of Polish nurses to migrate for work to other countries in the European region. The study included 581 nurses, professionally active in Poland over the duration of the study. The Computer Assisted Web Interview technique was used to collect data. Nurses filled in a web-based questionnaire that was available from December 5, 2011, to March 5, 2012. The choice of respondents for the sample was based on the availability of data. An invitation to participate in the study could be viewed on selected websites from the Portal of Nurses and Midwives, the Supreme Chamber of Nurses and Midwives, and the Polish Nursing Society. The survey questionnaire was designed by the authors, which served as the primary research tool. Nearly one in three respondents intended to leave Poland for professional reasons. Overall, 12.4 % of respondents had already worked as a nurse abroad. The main destinations for migration included Germany, followed by England and Norway. The intended length of stay abroad ranged from 2-5 years. In the studied group of Polish nurses, there was great interest in seeking employment abroad. Nurses tend to go abroad mostly for long-term, repeated periods to the wealthiest countries nearest to Poland. In view of the low level of human resources in the Polish nursing sector, the migration of Polish nurses will probably have crucial implications for the quality of healthcare services in Poland in the coming years. Given the methodology applied, study findings refer solely to the study group.
A new polishing process for large-aperture and high-precision aspheric surface
NASA Astrophysics Data System (ADS)
Nie, Xuqing; Li, Shengyi; Dai, Yifan; Song, Ci
2013-07-01
The high-precision aspheric surface is hard to be achieved due to the mid-spatial frequency error in the finishing step. The influence of mid-spatial frequency error is studied through the simulations and experiments. In this paper, a new polishing process based on magnetorheological finishing (MRF), smooth polishing (SP) and ion beam figuring (IBF) is proposed. A 400mm aperture parabolic surface is polished with this new process. The smooth polishing (SP) is applied after rough machining to control the MSF error. In the middle finishing step, most of low-spatial frequency error is removed by MRF rapidly, then the mid-spatial frequency error is restricted by SP, finally ion beam figuring is used to finish the surface. The surface accuracy is improved from the initial 37.691nm (rms, 95% aperture) to the final 4.195nm. The results show that the new polishing process is effective to manufacture large-aperture and high-precision aspheric surface.
Electro-rheological finishing for optical surfaces
NASA Astrophysics Data System (ADS)
Cheng, Haobo; Wang, Peng
2009-05-01
Many polishing techniques such as fixed-abrasive polishing, abrasive-free polishing and magnetorheological finishing etc., have been developed. Meanwhile, a new technique is proposed using the mixture of the electro-rheological (Er) fluid with abrasives as polishing slurry, which is a special process does not require pad. Electrorheological fluid is a special suspension liquid, whose viscosity has an approximate proportional relation with the electric strength applied. When the field strength reaches a certain limit, the phase transition occurs and the liquid acquires a solid like character, and while the electric field is removed, the fluid regains its original viscosity during the order of milliseconds. In this research work, we employed the characteristics of viscosity change of Er fluid to hold the polishing particles for micromachining. A point-contact electro-rheological finishing (Erf) tool was designed with a tip diameter 0.5~1mm. Both the anode and the cathode of the electric field were combined in the tool. The electric field could be controllable. When the tool moves across the profile of the work piece, by controlling the electric field strength as well as the other manufacturing parameters we can assure the deterministic material removal. Furthermore, the electro-rheological finishing process has been planned in detailed.
Improving material removal determinacy based on the compensation of tool influence function
NASA Astrophysics Data System (ADS)
Zhong, Bo; Chen, Xian-hua; Deng, Wen-hui; Zhao, Shi-jie; Zheng, Nan
2018-03-01
In the process of computer-controlled optical surfacing (CCOS), the key of correcting the surface error of optical components is to ensure the consistency between the simulated tool influence function and the actual tool influence function (TIF). The existing removal model usually adopts the fixed-point TIF to remove the material with the planning path and velocity, and it considers that the polishing process is linear and time invariant. However, in the actual polishing process, the TIF is a function related to the feed speed. In this paper, the relationship between the actual TIF and the feed speed (i.e. the compensation relationship between static removal and dynamic removal) is determined by experimental method. Then, the existing removal model is modified based on the compensation relationship, to improve the conformity between simulated and actual processing. Finally, the surface error modification correction test are carried out. The results show that the fitting degree of the simulated surface and the experimental surface is better than 88%, and the surface correction accuracy can be better than 1/10 λ (Λ=632.8nm).
The Development of a Deflectometer for Accurate Surface Figure Metrology
NASA Technical Reports Server (NTRS)
Gubarev, Mikhail; Eberhardt, Andrew; Ramsey, Brian; Atkins, Carolyn
2015-01-01
Marshall Space Flight Center is developing the method of direct fabrication for high resolution full-shell x-ray optics. In this technique the x-ray optics axial profiles are figured and polished using a computer-controlled ZeekoIRP600X polishing machine. Based on the Chandra optics fabrication history about one third of the manufacturing time is spent on moving a mirror between fabrication and metrology sites, reinstallation and alignment with either the metrology or fabrication instruments. Also, the accuracy of the alignment significantly affects the ultimate accuracy of the resulting mirrors. In order to achieve higher convergence rate it is highly desirable to have a metrology technique capable of in situ surface figure measurements of the optics under fabrication, so the overall fabrication costs would be greatly reduced while removing the surface errors due to the re-alignment necessary after each metrology cycle during the fabrication. The goal of this feasibility study is to demonstrate if the Phase Measuring Deflectometry can be applied for in situ metrology of full shell x-ray optics. Examples of the full-shell mirror substrates suitable for the direct fabrication
The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics
Demirci, Tevfik; Demirci, Gamze; Sagsoz, Nurdan Polat; Yildiz, Mehmet
2016-01-01
PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics. PMID:28018558
NASA Astrophysics Data System (ADS)
Chen, Hua; Chen, Jihong; Wang, Baorui; Zheng, Yongcheng
2016-10-01
The Magnetorheological finishing (MRF) process, based on the dwell time method with the constant normal spacing for flexible polishing, would bring out the normal contour error in the fine polishing complex surface such as aspheric surface. The normal contour error would change the ribbon's shape and removal characteristics of consistency for MRF. Based on continuously scanning the normal spacing between the workpiece and the finder by the laser range finder, the novel method was put forward to measure the normal contour errors while polishing complex surface on the machining track. The normal contour errors was measured dynamically, by which the workpiece's clamping precision, multi-axis machining NC program and the dynamic performance of the MRF machine were achieved for the verification and security check of the MRF process. The unit for measuring the normal contour errors of complex surface on-machine was designed. Based on the measurement unit's results as feedback to adjust the parameters of the feed forward control and the multi-axis machining, the optimized servo control method was presented to compensate the normal contour errors. The experiment for polishing 180mm × 180mm aspherical workpiece of fused silica by MRF was set up to validate the method. The results show that the normal contour error was controlled in less than 10um. And the PV value of the polished surface accuracy was improved from 0.95λ to 0.09λ under the conditions of the same process parameters. The technology in the paper has been being applied in the PKC600-Q1 MRF machine developed by the China Academe of Engineering Physics for engineering application since 2014. It is being used in the national huge optical engineering for processing the ultra-precision optical parts.
Kim, Dae Wook; Kim, Sug-Whan
2005-02-07
We present a novel simulation technique that offers efficient mass fabrication strategies for 2m class hexagonal mirror segments of extremely large telescopes. As the first of two studies in series, we establish the theoretical basis of the tool influence function (TIF) for precessing tool polishing simulation for non-rotating workpieces. These theoretical TIFs were then used to confirm the reproducibility of the material removal foot-prints (measured TIFs) of the bulged precessing tooling reported elsewhere. This is followed by the reverse-computation technique that traces, employing the simplex search method, the real polishing pressure from the empirical TIF. The technical details, together with the results and implications described here, provide the theoretical tool for material removal essential to the successful polishing simulation which will be reported in the second study.
O'Brien, C; Charman, W N
2006-05-01
After a preliminary investigation of the effects of tool feed rate and spindle speed on the surface roughness of unhydrated, lathe-cut polymacon surfaces, a laboratory and clinical comparison was made between lenses with identical parameters except that the lathe-cut posterior surface was left unpolished in the "test" lenses and was polished in the "control" lenses. The lenses had moulded anterior surfaces. Laboratory comparisons included surface roughness, lens power and its uniformity across the surface. Double-blind clinical trials over 4-hour (27 subjects) and 1-month (10 subjects) periods, involved one eye of each subject wearing a "test" lens and the other, a "control" lens. No clinically significant differences were found between the results for the test and control lenses. It is concluded that today's lathing technology makes a final polishing stage unnecessary.
Apparatus and method for deterministic control of surface figure during full aperture polishing
Suratwala, Tayyab Ishaq; Feit, Michael Dennis; Steele, William Augustus
2013-11-19
A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. The first and second radial directions may be opposite directions.
In vitro cytotoxicity of traditional versus contemporary dental ceramics.
Messer, Regina L W; Lockwood, Petra E; Wataha, John C; Lewis, Jill B; Norris, Samuel; Bouillaguet, Serge
2003-11-01
The biocompatibility of new dental ceramics has not been assessed with the same scrutiny as has been applied to alloys and composites. Yet, the biocompatibility of ceramics is critical to the long-term success of dental prostheses because ceramics are in close contact with oral tissues for extended periods. Five dental ceramics (2 traditional feldspathic veneer porcelains [Vita Omega and Duceragold], 2 lithium disilicate pressable materials [Stylepress and Empress-2], and a pressable leucite-based material [Empress-1]) were tested for their ability to alter cellular mitochondrial dehydrogenase activity after fabrication using a tetrazolium assay, after aging for 2 weeks in a biologic solution and after post-aging polishing with either a fine diamond or diamond polishing paste. Cellular responses were compared with polytetrafluoroethylene controls (analysis of variance, Tukey pairwise post-hoc comparison, alpha=.05). The feldspathic porcelains caused only mild (<25% of controls) mitochondrial suppression regardless of aging or polishing. The pressable leucite-based material initially caused a 5% stimulation (not significant) of mitochondrial activity, which decreased significantly (P<.05) by 30% with aging to levels comparable to the feldspathic porcelains, and did not change with polishing. Both lithium disilicate materials caused an initial suppression of mitochondrial activity that decreased significantly with aging, but Empress-2 was severely cytotoxic initially (<20% of controls, P<.01), and became more cytotoxic again after polishing. Stylepress was less cytotoxic initially (85% of controls, not significant) and did not become cytotoxic again after polishing. Dental ceramics are not equivalent in their in vitro biologic effects, even within the same class of material, and biologic safety should not be assumed. Most ceramics caused only mild in vitro suppression of cell function to levels that would be acceptable on the basis of standards used to evaluate alloys and composites. However, 1 Li-disilicate material (Empress-2) exhibited cytotoxicity that would not be deemed biologically acceptable on the basis of prevailing empirical standards for dental alloys and composites.
Bonner, Brian C; Young, Linda; Smith, Patricia A; McCombes, Wendy; Clarkson, Jan E
2005-01-01
Background To investigate, within general dental practice, patients' and vocational dental practitioners' (VDP) attitudes towards the benefits and costs of a simple scale and polish and to compare the experience of using manual versus ultrasonic instruments to scale teeth. Methods 28 VDPs and 420 patients participated. Patients were randomly allocated to either group. Patients' and VDPs' attitudes towards, and experience of, the scale and polish were elicited by means of self-administered questionnaires. Results The majority of patients (99%) believed a scale and polish was beneficial. VDPs considered ultrasonic treatment to be appropriate on significantly more occasions than they did for manual scale and polish (P < 0.001). Patient discomfort: with ultrasonic scaling 69.2% felt 'a little uncomfortable' or worse compared with 60% of those undergoing manual treatment (P = 0.072). VDPs considered treatment charges were appropriate for 77% of patients. Conclusion Routine scaling and polishing is considered beneficial by both patients and vocational trainees. The majority of patients, regardless of treatment method, experience some degree of discomfort when undergoing a scale and polish. VDPs showed a preference for the ultrasonic treatment method. PMID:15975140
Riegel, Monika; Wierzba, Małgorzata; Wypych, Marek; Żurawski, Łukasz; Jednoróg, Katarzyna; Grabowska, Anna; Marchewka, Artur
2015-12-01
In the present article, we introduce the Nencki Affective Word List (NAWL), created in order to provide researchers with a database of 2,902 Polish words, including nouns, verbs, and adjectives, with ratings of emotional valence, arousal, and imageability. Measures of several objective psycholinguistic features of the words (frequency, grammatical class, and number of letters) are also controlled. The database is a Polish adaptation of the Berlin Affective Word List-Reloaded (BAWL-R; Võ et al., Behavior Research Methods 41:534-538, 2009), commonly used to investigate the affective properties of German words. Affective normative ratings were collected from 266 Polish participants (136 women and 130 men). The emotional ratings and psycholinguistic indexes provided by NAWL can be used by researchers to better control the verbal materials they apply and to adjust them to specific experimental questions or issues of interest. The NAWL is freely accessible to the scientific community for noncommercial use as supplementary material to this article.
He, Wanling; Shohag, M J I; Wei, Yanyan; Feng, Ying; Yang, Xiaoe
2013-12-15
The present study compared the effects of four different forms of foliar iron (Fe) fertilizers on Fe concentration, bioavailability and nutritional quality of polished rice. The results showed that foliar fertilisation at the anthesis stage was an effective way to promote Fe concentration and bioavailability of polished rice, especially in case of DTPA-Fe. Compared to the control, foliar application of DTPA-Fe increased sulphur concentration and the nutrition promoter cysteine content, whereas decreased phosphorus concentration and the antinutrient phytic acid content of polished rice, as a result increased 67.2% ferrtin formation in Caco-2 cell. Moreover, foliar DTPA-Fe application could maintain amylase, protein and minerals quality of polished rice. According to the current study, DTPA-Fe is recommended as an excellent foliar Fe form for Fe biofortification program. Copyright © 2013 Elsevier Ltd. All rights reserved.
Spontaneous Movements of a Computer Mouse Reveal Egoism and In-group Favoritism.
Maliszewski, Norbert; Wojciechowski, Łukasz; Suszek, Hubert
2017-01-01
The purpose of the project was to assess whether the first spontaneous movements of a computer mouse, when making an assessment on a scale presented on the screen, may express a respondent's implicit attitudes. In Study 1, the altruistic behaviors of 66 students were assessed. The students were led to believe that the task they were performing was also being performed by another person and they were asked to distribute earnings between themselves and the partner. The participants performed the tasks under conditions with and without distractors. With the distractors, in the first few seconds spontaneous mouse movements on the scale expressed a selfish distribution of money, while later the movements gravitated toward more altruism. In Study 2, 77 Polish students evaluated a painting by a Polish/Jewish painter on a scale. They evaluated it under conditions of full or distracted cognitive abilities. Spontaneous movements of the mouse on the scale were analyzed. In addition, implicit attitudes toward both Poles and Jews were measured with the Implicit Association Test (IAT). A significant association between implicit attitudes (IAT) and spontaneous evaluation of images using a computer mouse was observed in the group with the distractor. The participants with strong implicit in-group favoritism of Poles revealed stronger preference for the Polish painter's work in the first few seconds of mouse movement. Taken together, these results suggest that spontaneous mouse movements may reveal egoism (in-group favoritism), i.e., processes that were not observed in the participants' final decisions (clicking on the scale).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, Tayyab
The high level objectives of the this work were to: 1) scientifically understand critical phenomena affecting the surface figure during full aperture finishing; 2) utilize these fundamentals to more deterministically control the surface figure during finishing; 3) successfully polish under rogue particle-‘free’ environments during polishing by understanding/preventing key sources of rogue particles.
Sharan, Smitha; Kavitha, H R; Konde, Harish; Kalahasti, Deepthi
2012-05-01
To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.
Beltrami, Riccardo; Ceci, Matteo; De Pani, Gabriele; Vialba, Lodovico; Federico, Ricaldone; Poggio, Claudio; Colombo, Marco
2018-01-01
Objective: To evaluate the color stability of different esthetic restorative materials after surface finishing/polishing with different procedures. Materials and Methods: All materials were polymerized into silicone rubber rings to obtain specimens identical in size. Samples were randomly assigned into four groups (10 specimens of each composite for each group), and they were finished with different procedures: Control group (Group 1), three or two polishers interspersed with diamond grit (Groups 3 and 2, respectively), and one tungsten carbide bur + one polisher interspersed with diamond grit (Group 4). After staining process in coffee, a colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, and 28 days. Shapiro–Wilk test and Kruskal–Wallis analysis of variance were applied to assess significant differences among restorative materials. Means of the different polishing/finishing groups were compared with Scheffe's multiple comparison test at the 0.05 level of significance. Results: In control group, significant lower discolorations were recorded for Essentia, Admira Fusion, and Estelite. After finishing, Filtek Supreme XTE and Ceram.X Universal showed a significantly lower degree of staining. The finishing technique used for Group 4 produced higher color changes. Conclusions: Tungsten carbide burs produced the higher color variations; after finishing, the nanofilled composites showed lower discoloration than nanohybrid ones, and the time of exposure to the staining agent and the polishing/finishing technique influenced the color change. PMID:29657525
Subgingival air-polishing with erythritol during periodontal maintenance
Müller, Nada; Moëne, Raphaël; Cancela, José A; Mombelli, Andrea
2014-01-01
Objectives To evaluate repeated subgingival air-polishing in residual pockets with a new erythritol powder containing 0.3% chlorhexidine. Material and Methods Single-centre, examiner masked, randomized clinical trial of 12 months with a two-arm, within-subject parallel design. Fifty patients in periodontal maintenance were monitored in 3-month intervals. At months 0, 3, 6 and 9, all sites presenting with a probing depth (PD) >4 mm were subject to subgingival air-polishing (test side) or ultrasonic debridement (control side). The primary endpoint was presence/absence of PD >4 mm after 12 months. Results Totally 6918 sites were monitored at baseline, 457 of them had a PD >4 mm (range 5–9 mm). The number of pockets >4 mm per subject, PD and bleeding on probing were significantly lower at month 12. Differences between test and control were not significant. There was a significant difference in favour of air-polishing for the perception of pain/discomfort. Differences of frequencies at >1000 and >100,000 cells/ml of six microorganisms between baseline and month 12 were not significant. At month 12, test sites were less frequently positive for Aggregatibacter actinomycetemcomitans at >1000 cells/ml than controls, and counts never exceeded 100,000 cells/ml. Conclusions Repeated subgingival air-polishing reduced the number of pockets >4 mm similar to ultrasonic debridement. It was safe and induced less pain. PMID:25041441
Effects of air-polishing powders on color stability of composite resins.
Güler, Ahmet Umut; Duran, Ibrahim; Yücel, Ali Çağin; Ozkan, Pelin
2011-10-01
The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90°. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37°C. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p<0.05). According to the 2-way ANOVA results, composite resin restorative materials, air-polishing powders, and their interaction were statistically significant (p<0.05) For Aelite Aesthetic Enemal, Filtek Z250, Grandio, CeramX Mono, and Quixfil composite resin restorative materials, no significant difference was observed between Group-PS and Group-CP (p>.05) and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less ∆E* values than the other composite resins tested. The highest ∆E* values were observed in Quixfil. Except for Quixfil, all control groups of composite resins that were polished Sof-Lex exhibited clinically acceptable ∆E values (<3.7). Air-polishing applications increased the color change for all composite resin restorative materials tested. Composite restorations may require re-polishing after air-polishing.
Effects of air-polishing powders on color stability of composite resins
GÜLER, Ahmet Umut; DURAN, Ibrahim; YÜCEL, Ali Çagin; ÖZKAN, Pelin
2011-01-01
Objectives The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. Material and methods Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90º. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37ºC. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p≤0.05). Results According to the 2-way ANOVA results, composite resin restorative materials, air-polishing powders, and their interaction were statistically significant (p<0.05) For Aelite Aesthetic Enemal, Filtek Z250, Grandio, CeramX Mono, and Quixfil composite resin restorative materials, no significant difference was observed between Group-PS and Group-CP (p>.05) and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less ∆E* values than the other composite resins tested. The highest ∆E* values were observed in Quixfil. Conclusion Except for Quixfil, all control groups of composite resins that were polished Sof-Lex exhibited clinically acceptable ∆E values (<3.7). Air-polishing applications increased the color change for all composite resin restorative materials tested. Composite restorations may require re-polishing after air-polishing. PMID:21922122
Apparatus and method for deterministic control of surface figure during full aperture pad polishing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, Tayyab Ishaq; Feit, Michael Douglas; Steele, William Augustus
A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. Themore » first and second radial directions may be opposite directions.« less
Evaluation of surface roughness and polishing techniques for new ceramic materials.
Campbell, S D
1989-05-01
The surface roughness of crown and bridge materials should be minimized to obtain optimal biocompatability. This study used scanning electron microscopy to evaluate the effect of polishing procedures on two all-ceramic crown materials (Dicor and Cerestore). The "as formed," unpolished specimens of both Dicor and Cerestore materials presented a rough surface. It was found that any attempt to polish the Cerestore coping material resulted in an extremely rough surface. Finishing of the Dicor ceramic resulted in a smoother but pitted surface. Polishing of both ceramic materials resulted in a surface that was rougher than the glazed metal ceramic controls. The smoothest finish was obtained when the glazed veneer (Cerestore) and shading porcelain (Dicor) were applied to the all-ceramic materials.
Acar, Burcu; Egilmez, Ferhan
2018-04-01
To investigate and compare the effects of several polishing systems and thermal cycling on the surface roughness and color change of various polymer-based CAD/CAM materials. Bar-shaped specimens (GC CeraSmart, CS; Lava Ultimate, LU and Vita Enamic, VE) were prepared. All specimens were polished with SiC papers. The specimens in Group A served as control and no additional surface polishing was applied. Final polishing was performed using diamond polishing paste (Diapolisher Paste) in Group B. In Group C, aluminum oxide abrasive discs (Sof-Lex XT Pop on) were used. Group D was polished with diamond impregnated spiral polishing system (EVE Diacomp Plus Twist). In Group E, polishing was done with rubber-based silicon abrasives (Polydentia). Thereafter, the specimens were submitted to thermal cycling. The surface roughness and color measurements were performed. Kruskal-Wallis and the Mann-Whitney U tests were applied for the evaluation of ΔE₀₀ data. Ra data were evaluated using three-way ANOVA. Pearson's correlation between Ra and ΔE₀₀ was further investigated. Neither the CAD/CAM materials nor thermal cycling affected the Ra data (P> 0.05). In contrast, significant difference was found among the polishing methods (P< 0.001). On the other hand, VE showed the highest color change whereas LU showed the lowest (P< 0.05). Additionally, the specimens in Group D exhibited significantly higher color change than other tested groups (P< 0.05). A moderate positive correlation was seen between Ra and ΔE₀₀ data of LU (rho = 0.390, P= 0.01). The diamond impregnated two-stage polishing procedure may not be an appropriate method for the tested CAD/CAM materials, as it resulted in the highest color change. On the other hand, all tested materials exhibited visually perceptible, but clinically acceptable color changes following the different polishing techniques. Additionally, diamond paste polishing could be a clinically acceptable procedure in terms of surface roughness. Copyright©American Journal of Dentistry.
Dwell-time algorithm for polishing large optics.
Wang, Chunjin; Yang, Wei; Wang, Zhenzhong; Yang, Xu; Hu, Chenlin; Zhong, Bo; Guo, Yinbiao; Xu, Qiao
2014-07-20
The calculation of the dwell time plays a crucial role in polishing precision large optics. Although some studies have taken place, it remains a challenge to develop a calculation algorithm which is absolutely stable, together with a high convergence ratio and fast solution speed even for extremely large mirrors. For this aim, we introduced a self-adaptive iterative algorithm to calculate the dwell time in this paper. Simulations were conducted in bonnet polishing (BP) to test the performance of this method on a real 430 mm × 430 mm fused silica part with the initial surface error PV=1741.29 nm, RMS=433.204 nm. The final surface residual error in the clear aperture after two simulation steps turned out to be PV=11.7 nm, RMS=0.5 nm. The results confirm that this method is stable and has a high convergence ratio and fast solution speed even with an ordinary computer. It is notable that the solution time is usually just a few seconds even on a 1000 mm × 1000 mm part. Hence, we believe that this method is perfectly suitable for polishing large optics. And not only can it be applied to BP, but it can also be applied to other subaperture deterministic polishing processes.
Color stability of nanocomposites polished with one-step systems.
Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin
2008-01-01
This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.
Occupational factors and pancreatic cancer.
Norell, S; Ahlbom, A; Olin, R; Erwald, R; Jacobson, G; Lindberg-Navier, I; Wiechel, K L
1986-01-01
The relation between occupational factors and pancreatic cancer has been studied by two different approaches: a population based case-control study with two series of controls and a retrospective cohort study based on register data. With both approaches, some support was found for an association with occupational exposure to petroleum products. Associations were also indicated with exposure to paint thinner (case-control study) and work in painting and in paint and varnish factories (cohort study), for exposure to detergents, floor cleaning agents, or polish (case-control study) and with floor polishing or window cleaning (cohort study), and for exposure to refuse (case-control study) and work in refuse disposal plants (cohort study). PMID:3790458
Interruption as a test of the user-computer interface
NASA Technical Reports Server (NTRS)
Kreifeldt, J. G.; Mccarthy, M. E.
1981-01-01
In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.
Dynamic deformation measurement and analysis of active stressed lap using optical method
NASA Astrophysics Data System (ADS)
Zhang, Qican; Su, Xianyu; Liu, Yuankun; Xiang, Liqun
2007-12-01
The active stressed lap is the heart of polishing process. A novel non-contact optical method of dynamic deformation measurement and analysis of an active stressed lap is put forward. This method, based on structured illumination, is able to record full-field information of the bending and rotating stressed lap dynamically and continuously, while its profile is changed under computer control, and restore the whole process of lap deformation varied with time at different position and rotating angle. It has been verified by experiments that this proposed method will be helpful to the opticians to ensure the stressed lap as expected.
Introduction to Cosmology, Proceedings of the Polish Astronomical Society volume 4
NASA Astrophysics Data System (ADS)
Biernacka, Monika; Bajan, Katarzyna; Stachowski, Grzegorz; Pollo, Agnieszka
2016-07-01
On 11-23 July 2016, Jan Kochanowski University in Kielce was the host of the Second Cosmological School "Introduction to Cosmology". The main purpose of the School was to provide an introduction to a selection of the most interesting topics in modern cosmology, both in theory and observations. The program included a series of mini-workshops on cosmological simulations, Virtual Observatory database and tools and Spectral Energy Distribution tting. The School was intended for undergraduate, MSc and PhD students, as well as young postdoctoral researchers. The School was co-organized by the Polish Astronomical Society, the Jan Kochanowski University in Kielce, the Jagiellonian University in Cracow, the Nuclear Centre for Nuclear Research and the N. Copernicus Astronomical Center in Warsaw. The Interdisciplinary Centre for Mathematical and Computational Modeling kindly provided us with the possibility to remotely use their computing facilities.
Introduction to Cosmology, Proceedings of the Polish Astronomical Society volume 4
NASA Astrophysics Data System (ADS)
Biernacka, Monika; Bajan, Katarzyna; Stachowski, Grzegorz; Pollo, Agnieszka
2017-08-01
On 11-23 July 2016, Jan Kochanowski University in Kielce was the host of the Second Cosmological School "Introduction to Cosmology". The main purpose of the School was to provide an introduction to a selection of the most interesting topics in modern cosmology, both in theory and observations. The program included a series of mini-workshops on cosmological simulations, Virtual Observatory database and tools and Spectral Energy Distribution tting. The School was intended for undergraduate, MSc and PhD students, as well as young postdoctoral researchers. The School was co-organized by the Polish Astronomical Society, the Jan Kochanowski University in Kielce, the Jagiellonian University in Cracow, the Nuclear Centre for Nuclear Research and the N. Copernicus Astronomical Center in Warsaw. The Interdisciplinary Centre for Mathematical and Computational Modeling kindly provided us with the possibility to remotely use their computing facilities.
Ethical and Moral Education: A National Case Study of Poland.
ERIC Educational Resources Information Center
Janowski, Andrzej
This study explores the Polish experience in values education. Between the years 1944 and 1989 Polish education was often state controlled with the sole purpose of subjugating education to Marxist-Leninist ideology. Over the years the communist party's dictates varied in intensity. Despite the party's efforts to prescribe ethics, certain values…
The Educational System of Poland. Education around the World.
ERIC Educational Resources Information Center
Apanasewicz, Nellie
Polish education is described in terms of its history, structure, legal policies, and reforms. After having been controlled by various parties since the late 18th century, Polish education is now consolidated under two administrative bodies, one for elementary and secondary education and one for higher education. At all levels, education is free.…
Jang, J-H; Kim, H-Y; Shin, S-M; Lee, C-O; Kim, D S; Choi, K-K; Kim, S-Y
The aim of this randomized controlled clinical trial was to compare the clinical effectiveness of different polishing systems and self-etch adhesives in class V composite resin restorations. A total of 164 noncarious cervical lesions (NCCLs) from 35 patients were randomly allocated to one of four experimental groups, each of which used a combination of polishing systems and adhesives. The two polishing systems used were Sof-Lex XT (Sof), a multistep abrasive disc, and Enhance/Pogo (EP), a simplified abrasive-impregnated rubber instrument. The adhesive systems were Clearfil SE bond (CS), a two-step self-etch adhesive, and Xeno V (XE), a one-step self-etch adhesive. All NCCLs were restored with light-cured microhybrid resin composites (Z250). Restorations were evaluated at baseline and at 6, 12, 18, and 24 months by two blinded independent examiners using modified FDI criteria. The Fisher exact test and generalized estimating equation analysis considering repeated measurements were performed to compare the outcomes between the polishing systems and adhesives. Three restorations were dislodged: two in CS/Sof and one in CS/EP. None of the restorations required any repair or retreatment except those showing retention loss. Sof was superior to EP with regard to surface luster, staining, and marginal adaptation (p<0.05). CS and XE did not show differences in any criteria (p>0.05). Sof is clinically superior to EP for polishing performance in class V composite resin restoration. XE demonstrates clinically equivalent bonding performance to CS.
Dong, Hui; Wang, Lili; Gao, Wei; Li, Xiaoyuan; Wang, Chao; Ji, Fang; Pan, Jinlong; Wang, Baorui
2017-01-01
A novel functional KH2PO4 (KDP) aqueous solution-in-oil (KDP aq/O) microemulsion system for KDP crystal ultra-precision chemical-mechanical polishing (CMP) was prepared. The system, which consisted of decanol, Triton X-100, and KH2PO4 aqueous solution, was available at room temperature. The functional KDP aq/O microemulsion system was systematically studied and applied as polishing solution to KDP CMP technology. In this study, a controlled deliquescent mechanism was proposed for KDP polishing with the KDP aq/O microemulsion. KDP aqueous solution, the chemical etchant in the polishing process, was caged into the micelles in the microemulsion, leading to a limitation of the reaction between the KDP crystal and KDP aqueous solution only if the microemulsion was deformed under the effect of the external force. Based on the interface reaction dynamics, KDP aqueous solutions with different concentrations (cKDP) were applied to replace water in the traditional water-in-oil (W/O) microemulsion. The practicability of the controlled deliquescent mechanism was proved by the decreasing material removal rate (MRR) with the increasing of the cKDP. As a result, the corrosion pits on the KDP surface were avoided to some degree. Moreover, the roughnesses of KDP with KDP aq/O microemulsion (cKDP was changed from 10 mM to 100 mM) as polishing solutions were smaller than that with the W/O microemulsion. The smallest surface root-mean-square roughness of 1.5 nm was obtained at a 30 mmol/L KDP aq solution, because of the most appropriate deliquescent rate and MRR. PMID:28772632
Dong, Hui; Wang, Lili; Gao, Wei; Li, Xiaoyuan; Wang, Chao; Ji, Fang; Pan, Jinlong; Wang, Baorui
2017-03-09
A novel functional KH₂PO₄ (KDP) aqueous solution-in-oil (KDP aq/O) microemulsion system for KDP crystal ultra-precision chemical-mechanical polishing (CMP) was prepared. The system, which consisted of decanol, Triton X-100, and KH₂PO₄ aqueous solution, was available at room temperature. The functional KDP aq/O microemulsion system was systematically studied and applied as polishing solution to KDP CMP technology. In this study, a controlled deliquescent mechanism was proposed for KDP polishing with the KDP aq/O microemulsion. KDP aqueous solution, the chemical etchant in the polishing process, was caged into the micelles in the microemulsion, leading to a limitation of the reaction between the KDP crystal and KDP aqueous solution only if the microemulsion was deformed under the effect of the external force. Based on the interface reaction dynamics, KDP aqueous solutions with different concentrations ( c KDP ) were applied to replace water in the traditional water-in-oil (W/O) microemulsion. The practicability of the controlled deliquescent mechanism was proved by the decreasing material removal rate (MRR) with the increasing of the c KDP . As a result, the corrosion pits on the KDP surface were avoided to some degree. Moreover, the roughnesses of KDP with KDP aq/O microemulsion ( c KDP was changed from 10 mM to 100 mM) as polishing solutions were smaller than that with the W/O microemulsion. The smallest surface root-mean-square roughness of 1.5 nm was obtained at a 30 mmol/L KDP aq solution, because of the most appropriate deliquescent rate and MRR.
Investigation of aluminum gate CMP in a novel alkaline solution
NASA Astrophysics Data System (ADS)
Cuiyue, Feng; Yuling, Liu; Ming, Sun; Wenqian, Zhang; Jin, Zhang; Shuai, Wang
2016-01-01
Beyond 45 nm, due to the superior CMP performance requirements with the metal gate of aluminum in the advanced CMOS process, a novel alkaline slurry for an aluminum gate CMP with poly-amine alkali slurry is investigated. The aluminum gate CMP under alkaline conditions has two steps: stock polishing and fine polishing. A controllable removal rate, the uniformity of aluminum gate and low corrosion are the key challenges for the alkaline polishing slurry of the aluminum gate CMP. This work utilizes the complexation-soluble function of FA/O II and the preference adsorption mechanism of FA/O I nonionic surfactant to improve the uniformity of the surface chemistry function with the electrochemical corrosion research, such as OCP-TIME curves, Tafel curves and AC impedance. The result is that the stock polishing slurry (with SiO2 abrasive) contains 1 wt.% H2O2,0.5 wt.% FA/O II and 1.0 wt.% FA/O I nonionic surfactant. For a fine polishing process, 1.5 wt.% H2O2, 0.4 wt.% FA/O II and 2.0 wt.% FA/O I nonionic surfactant are added. The polishing experiments show that the removal rates are 3000 ± 50 Å/min and 1600 ± 60 Å/min, respectively. The surface roughnesses are 2.05 ± 0.128 nm and 1.59 ± 0.081 nm, respectively. A combination of the functions of FA/O II and FA/O I nonionic surfactant obtains a controllable removal rate and a better surface roughness in alkaline solution.
Li, Hongyu; Walker, David; Yu, Guoyu; Sayle, Andrew; Messelink, Wilhelmus; Evans, Rob; Beaucamp, Anthony
2013-01-14
Edge mis-figure is regarded as one of the most difficult technical issues for manufacturing the segments of extremely large telescopes, which can dominate key aspects of performance. A novel edge-control technique has been developed, based on 'Precessions' polishing technique and for which accurate and stable edge tool influence functions (TIFs) are crucial. In the first paper in this series [D. Walker Opt. Express 20, 19787-19798 (2012)], multiple parameters were experimentally optimized using an extended set of experiments. The first purpose of this new work is to 'short circuit' this procedure through modeling. This also gives the prospect of optimizing local (as distinct from global) polishing for edge mis-figure, now under separate development. This paper presents a model that can predict edge TIFs based on surface-speed profiles and pressure distributions over the polishing spot at the edge of the part, the latter calculated by finite element analysis and verified by direct force measurement. This paper also presents a hybrid-measurement method for edge TIFs to verify the simulation results. Experimental and simulation results show good agreement.
Active edge control in the precessions polishing process for manufacturing large mirror segments
NASA Astrophysics Data System (ADS)
Li, Hongyu; Zhang, Wei; Walker, David; Yu, Gouyo
2014-09-01
The segmentation of the primary mirror is the only promising solution for building the next generation of ground telescopes. However, manufacturing segmented mirrors presents its own challenges. The edge mis-figure impacts directly on the telescope's scientific output. The `Edge effect' significantly dominates the polishing precision. Therefore, the edge control is regarded as one of the most difficult technical issues in the segment production that needs to be addressed urgently. This paper reports an active edge control technique for the mirror segments fabrication using the Precession's polishing technique. The strategy in this technique requires that the large spot be selected on the bulk area for fast polishing, and the small spot is used for edge figuring. This can be performed by tool lift and optimizing the dell time to compensate for non-uniform material removal at the edge zone. This requires accurate and stable edge tool influence functions. To obtain the full tool influence function at the edge, we have demonstrated in previous work a novel hybrid-measurement method which uses both simultaneous phase interferometry and profilometry. In this paper, the edge effect under `Bonnet tool' polishing is investigated. The pressure distribution is analyzed by means of finite element analysis (FEA). According to the `Preston' equation, the shape of the edge tool influence functions is predicted. With this help, the multiple process parameters at the edge zone are optimized. This is demonstrated on a 200mm crosscorners hexagonal part with a result of PV less than 200nm for entire surface.
Spontaneous Movements of a Computer Mouse Reveal Egoism and In-group Favoritism
Maliszewski, Norbert; Wojciechowski, Łukasz; Suszek, Hubert
2017-01-01
The purpose of the project was to assess whether the first spontaneous movements of a computer mouse, when making an assessment on a scale presented on the screen, may express a respondent’s implicit attitudes. In Study 1, the altruistic behaviors of 66 students were assessed. The students were led to believe that the task they were performing was also being performed by another person and they were asked to distribute earnings between themselves and the partner. The participants performed the tasks under conditions with and without distractors. With the distractors, in the first few seconds spontaneous mouse movements on the scale expressed a selfish distribution of money, while later the movements gravitated toward more altruism. In Study 2, 77 Polish students evaluated a painting by a Polish/Jewish painter on a scale. They evaluated it under conditions of full or distracted cognitive abilities. Spontaneous movements of the mouse on the scale were analyzed. In addition, implicit attitudes toward both Poles and Jews were measured with the Implicit Association Test (IAT). A significant association between implicit attitudes (IAT) and spontaneous evaluation of images using a computer mouse was observed in the group with the distractor. The participants with strong implicit in-group favoritism of Poles revealed stronger preference for the Polish painter’s work in the first few seconds of mouse movement. Taken together, these results suggest that spontaneous mouse movements may reveal egoism (in-group favoritism), i.e., processes that were not observed in the participants’ final decisions (clicking on the scale). PMID:28163689
NASA Technical Reports Server (NTRS)
Vilnrotter, Victor A.
2012-01-01
The potential development of large aperture ground-based "photon bucket" optical receivers for deep space communications has received considerable attention recently. One approach currently under investigation proposes to polish the aluminum reflector panels of 34-meter microwave antennas to high reflectance, and accept the relatively large spotsize generated by even state-of-the-art polished aluminum panels. Here we describe the experimental effort currently underway at the Deep Space Network (DSN) Goldstone Communications Complex in California, to test and verify these concepts in a realistic operational environment. A custom designed aluminum panel has been mounted on the 34 meter research antenna at Deep-Space Station 13 (DSS-13), and a remotely controlled CCD camera with a large CCD sensor in a weather-proof container has been installed next to the subreflector, pointed directly at the custom polished panel. Using the planet Jupiter as the optical point-source, the point-spread function (PSF) generated by the polished panel has been characterized, the array data processed to determine the center of the intensity distribution, and expected communications performance of the proposed polished panel optical receiver has been evaluated.
A Computer Program which Uses an Expert Systems Approach to Identifying Minerals.
ERIC Educational Resources Information Center
Hart, Allan Bruce; And Others
1988-01-01
Described is a mineral identification program which uses a shell system for creating expert systems of a classification nature. Discusses identification of minerals in hand specimens, thin sections, and polished sections of rocks. (Author/CW)
Hmaidouch, Rim; Müller, Wolf-Dieter; Lauer, Hans-Christoph; Weigl, Paul
2014-12-01
The aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces.
Hmaidouch, Rim; Müller, Wolf-Dieter; Lauer, Hans-Christoph; Weigl, Paul
2014-01-01
The aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces. PMID:25059249
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, Tayyab
2016-09-22
In the follow study, we have developed a detailed understanding of the chemical and mechanical microscopic interactions that occur during polishing affecting the resulting surface microroughness of the workpiece. Through targeted experiments and modeling, the quantitative relationships of many important polishing parameters & characteristics affecting surface microroughness have been determined. These behaviors and phenomena have been described by a number of models including: (a) the Ensemble Hertzian Multi Gap (EHMG) model used to predict the removal rate and roughness at atomic force microscope (AFM) scale lengths as a function of various polishing parameters, (b) the Island Distribution Gap (IDG) modelmore » used to predict the roughness at larger scale lengths, (c) the Deraguin-Verwey-Landau-Overbeek (DLVO) 3-body electrostatic colloidal model used to predict the interaction of slurry particles at the interface and roughness behavior as a function of pH, and (d) a diffusion/chemical reaction rate model of the incorporation of impurities species into the polishing surface layer (called the Bielby layer). Based on this improved understanding, novel strategies to polish the workpiece have been developed simultaneously leading to both ultrasmooth surfaces and high material removal rates. Some of these strategies include: (a) use of narrow PSD slurries, (b) a novel diamond conditioning recipe of the lap to increase the active contact area between the workpiece and lap without destroying its surface figure, (c) proper control of pH for a given glass type to allow for a uniform distribution of slurry particles at the interface, and (d) increase in applied load just up to the transition between molecular to plastic removal regime for a single slurry particle. These techniques have been incorporated into a previously developed finishing process called Convergent Polishing leading to not just economical finishing process with improved surface figure control, but also simultaneously leading to low roughness surface with high removal rates.« less
Astronomia.pl: Ideas for the International Year of Astronomy 2009
NASA Astrophysics Data System (ADS)
Czart, K.; Pomierny, J.
2008-06-01
Astronomia.pl is an internet portal for Polish-speaking people. As a website, most of our activities in IYA2009 will focus on the internet and other electronic media. We will prepare a content-rich website, in cooperation with the Polish committee for IYA2009. We present some extended suggestions for ideas proposed by the IAU, like postage stamps or mobile phone wallpapers, ring tones and themes and some original propositions like naming a small Solar System body for each country, a computer game, a stadium as a solar clock, a media event with thousands of amateur astronomers in one place and a network of cities.
Samoliński, B; Fronczak, A; Kuna, P; Akdis, C A; Anto, J M; Bialoszewski, A Z; Burney, P G; Bush, A; Czupryniak, A; Dahl, R; Flood, B; Galea, G; Jutel, M; Kowalski, M L; Palkonen, S; Papadopoulos, N; Raciborski, F; Sienkiewicz, D; Tomaszewska, A; Mutius, E; Willman, D; Włodarczyk, A; Yusuf, O; Zuberbier, T; Bousquet, J; Niggemann, Bodo
2012-01-01
The leading priority for the Polish Presidency of the Council of the European Union was to reduce health inequalities across European societies, and, within its framework, prevention and control of respiratory diseases in children. This very important paper contain proposal of international cooperation on the prevention, early detection and monitoring of asthma and allergic diseases in childhood which will be undertaken by the EU member countries as a result of EU conclusion developed during the Polish Presidency of the Council of the European Union. This will result in collaboration in the field of chronic diseases, particularly respiratory diseases, together with the activity of the network of national institutions and NGOs in this area. Paper also contains extensive analysis of the socio-economic, political, epidemiological, technological and medical factors affecting the prevention and control of childhood asthma and allergy presented during Experts presidential conference organized in Warsaw-Ossa 21–22 September 2011. PMID:22540290
Olszowski, Tomasz; Adler, Grażyna; Janiszewska-Olszowska, Joanna; Safranow, Krzysztof; Chlubek, Dariusz
2015-01-01
The aim of the study was to examine the frequencies of the genotypes and alleles of ACE insertion/deletion (I/D) polymorphism and their association with dental caries in a sample of Polish children. The study subjects were 120 children with dental caries experience (cases) and 41 caries-free individuals (controls). The genotyping was performed using polymerase chain reaction. The genotype distributions of ACE I/D polymorphism were not statistically different between carious and control children. However, we found a borderline overrepresentation of the II + ID genotypes versus the DD genotype in the carious compared to the control group (69.2% and 51.2%, respectively, p = 0.057). Logistic regression analysis adjusted for age and sex revealed that I allele carriage was a significant predictor of dental caries susceptibility (OR = 2.14, 95% CI = 1.02-4.49, p = 0.041). In conclusion, the DD genotype of ACE I/D polymorphism might be protective against dental caries in Polish children. © 2015 S. Karger AG, Basel.
Particulate emission abatement for Krakow boiler houses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wysk, S.R.; Surowka, J.
1995-11-01
Environmental clean-up and pollution control are considered top priorities in Poland. The magnitude of environmental problems and public awareness of it has forced the Polish government to implement more aggressive regulatory controls. The extent of this condition has in fact prompted the government to designate pollution control a a top priority for foreign investment. During the past five years, Poland has also made significant progress in reorienting its central-planned economy to one based on open market principals. Efforts to decentralize has led to the privatization of many government-owned businesses with a concomitant shift in buying decisions to privately-owned enterprises. Thismore » movement toward privatizing the economy along with cleaning and protecting the environment has created numerous business opportunities for both Polish and foreign companies. As a result, there has been a drastic downsizing of large formerly state-owned companies. And, new startups and small businesses have become the main hope in reviving the Polish economy.« less
Nano-Filament Field Emission Cathode Development Final Report CRADA No. TSB-0731-93
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernhardt, Tony; Fahlen, Ted
At the time the CRADA was established, Silicon Video Corporation, of Cupertino, CA was a one-year-old rapidly growing start-up company. SVC was developing flat panel displays (FPDs) to replace Cathode Ray Terminals (CRTs) for personal computers, work stations and televisions. They planned to base their products on low cost and energy efficient field emission technology. It was universally recognized that the display was both the dominant cost item and differentiating feature of many products such as laptop computers and hand-held electronics and that control of the display technology through U.S. sources was essential to success in these markets. The purposemore » of this CRADA project was to determine if electrochemical planarization would be a viable, inexpensive alternative to current optical polishing techniques for planarizing the surface of a ceramic backplate of a thin film display.« less
NASA Astrophysics Data System (ADS)
He, Qiuwei; Lv, Xingming; Wang, Xin; Qu, Xingtian; Zhao, Ji
2017-01-01
Blade is the key component in the energy power equipment of turbine, aircraft engines and so on. Researches on the process and equipment for blade finishing become one of important and difficult point. To control precisely tool system of developed hybrid grinding and polishing machine tool for blade finishing, the tool system with changeable wheel for belt polishing is analyzed in this paper. Firstly, the belt length and wrap angle of each wheel in different position of tension wheel swing angle in the process of changing wheel is analyzed. The reasonable belt length is calculated by using MATLAB, and relationships between wrap angle of each wheel and cylinder expansion amount of contact wheel are obtained. Then, the control system for changeable wheel tool structure is developed. Lastly, the surface roughness of blade finishing is verified by experiments. Theoretical analysis and experimental results show that reasonable belt length and wheel wrap angle can be obtained by proposed analysis method, the changeable wheel tool system can be controlled precisely, and the surface roughness of blade after grinding meets the design requirements.
Advances in photonic MOEMS-MEMS device thinning and polishing
NASA Astrophysics Data System (ADS)
McAneny, James J.; Kennedy, Mark; McGroggan, Tom
2010-02-01
As devices continue to increase in density and complexity, ever more stringent specifications are placed on the wafer scale equipment manufacturers to produce higher quality and higher output. This results in greater investment and more resource being diverted into producing tools and processes which can meet the latest demanding criteria. Substrate materials employed in the fabrication process range from Silicon through InP and include GaAs, InSb and other optical networking or waveguide materials. With this diversity of substrate materials presented, controlling the geometries and surfaces grows progressively more challenging. This article highlights the key parameters which require close monitoring and control in order to produce highly precise wafers as part of the fabrication process. Several as cut and commercially available standard polished wafer materials were used in empirical trials to test tooling options in generating high levels of geometric control over the dimensions while producing high quality surface finishes. Specific attention was given to the measurement and control of: flatness; parallelism/TTV; surface roughness and final target thickness as common specifications required by the industry. By combining the process variables of: plate speed, download pressure, slurry flow rate and concentration, pad type and wafer travel path across the polish pad, the effect of altering these variables was recorded and analysed to realize the optimum process conditions for the materials under test. The results being then used to design improved methods and tooling for the thinning and polishing of photonic materials applied to MOEMS-MEMS device fabrication.
Torabi, Kianoosh; Rasaeipour, Sasan; Ghodsi, Safoura; Khaledi, Amir Ali Reza; Vojdani, Mahroo
2014-07-01
The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance. This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness of the fiber reinforced composite (FRC), overglazed, autoglazed, or polished porcelain specimens. For overglazed, autoglazed, polished ceramics and also FRC cylindrical specimens (n = 20 per group) were prepared. The specimens were stored in distilled water at 37°C for 48 hours prior to testing. Six samples from each group were selected randomly as negative controls which were stored in distilled water at 37°C that was changed daily. CP 38% was applied on the test specimens for 15 minutes, twice a day for 14 days. By using Knoop-microhardness tester microhardness testing for baseline, control and test specimens was conducted. Data were statistically analyzed using paired t-test, Mann-Whitney test, and Kruskal-Wallis test. Home bleaching significantly decreased the surface microhardness of all the test samples (p < 0.05), whereas the control groups did not show statistically significant changes after 2 weeks. The polished porcelain and polished composite specimens showed the most significant change in microhard-ness after bleaching process (p < 0.05). Although the type of surface preparation affects the susceptibility of the porcelain surface to the bleaching agent, no special preparation can preclude such adverse effects. The contact of home bleaching agents with esthetic restorative materials is unavoidable. Therefore protecting these restorations from bleaching agents and reglazing or at least polishing the restorations after bleaching is recommended.
Form control in atmospheric pressure plasma processing of ground fused silica
NASA Astrophysics Data System (ADS)
Li, Duo; Wang, Bo; Xin, Qiang; Jin, Huiliang; Wang, Jun; Dong, Wenxia
2014-08-01
Atmospheric Pressure Plasma Processing (APPP) using inductively coupled plasma has demonstrated that it can achieve comparable removal rate on the optical surface of fused silica under the atmosphere pressure and has the advantage of inducing no sub-surface damage for its non-contact and chemical etching mechanism. APPP technology is a cost effective way, compared with traditional mechanical polishing, magnetorheological finishing and ion beam figuring. Thus, due to these advantages, this technology is being tested to fabricate large aperture optics of fused silica to help shorten the polishing time in optics fabrication chain. Now our group proposes to use inductively coupled plasma processing technology to fabricate ground surface of fused silica directly after the grinding stage. In this paper, form control method and several processing parameters are investigated to evaluate the removal efficiency and the surface quality, including the robustness of removal function, velocity control mode and tool path strategy. However, because of the high heat flux of inductively coupled plasma, the removal depth with time can be non-linear and the ground surface evolvement will be affected. The heat polishing phenomenon is founded. The value of surface roughness is reduced greatly, which is very helpful to reduce the time of follow-up mechanical polishing. Finally, conformal and deterministic polishing experiments are analyzed and discussed. The form error is less 3%, before and after the APPP, when 10μm depth of uniform removal is achieved on a 60×60mm ground fused silica. Also, a basin feature is fabricated to demonstrate the figuring capability and stability. Thus, APPP is a promising technology in processing the large aperture optics.
Fabrication of low cost soft tissue prostheses with the desktop 3D printer
NASA Astrophysics Data System (ADS)
He, Yong; Xue, Guang-Huai; Fu, Jian-Zhong
2014-11-01
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.
Fabrication of low cost soft tissue prostheses with the desktop 3D printer
He, Yong; Xue, Guang-huai; Fu, Jian-zhong
2014-01-01
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods. PMID:25427880
Fabrication of low cost soft tissue prostheses with the desktop 3D printer.
He, Yong; Xue, Guang-huai; Fu, Jian-zhong
2014-11-27
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.
ERIC Educational Resources Information Center
Rosen, Seymour M.; Apanasewicz, Nellie
1964-01-01
The previously published "Higher Education in Poland, Part I: Organization and Administration," and the present volume constitute an Office of Education study on the Polish system of higher learning. Part II explains the functioning of Polish institutions under control of the Ministry of Higher Education and other ministries, and…
NASA Astrophysics Data System (ADS)
Zhang, Chupeng; Zhao, Huiying; Zhu, Xueliang; Zhao, Shijie; Jiang, Chunye
2018-01-01
The chemical mechanical polishing (CMP) is a key process during the machining route of plane optics. To improve the polishing efficiency and accuracy, a CMP model and machine tool were developed. Based on the Preston equation and the axial run-out error measurement results of the m circles on the tin plate, a CMP model that could simulate the material removal at any point on the workpiece was presented. An analysis of the model indicated that lower axial run-out error led to lower material removal but better polishing efficiency and accuracy. Based on this conclusion, the CMP machine was designed, and the ultraprecision gas hydrostatic guideway and rotary table as well as the Siemens 840Dsl numerical control system were incorporated in the CMP machine. To verify the design principles of machine, a series of detection and machining experiments were conducted. The LK-G5000 laser sensor was employed for detecting the straightness error of the gas hydrostatic guideway and the axial run-out error of the gas hydrostatic rotary table. A 300-mm-diameter optic was chosen for the surface profile machining experiments performed to determine the CMP efficiency and accuracy.
Berner, Włodzimierz
2008-01-01
Acute infectious diseases of high intensity, i.e. typhus fever, typhoid fever, dysentery, followed by scarlet fever, measles, malaria, relapsing fever, whooping cough, diphtheria, smallpox and Asiatic cholera spreading after the World War I in Poland posed one of the most significant problems in the reviving country. Their incidence resulted not only from bad living conditions of the population but also from poor personal and environmental hygiene and lack of access to bacteriologically healthy drinking water. The Polish-Bolshevik war (1919-1920) as well as repatriation of war prisoners and the Polish population from Russia (its territory was a reservoir of numerous infectious diseases) and the return of large groups of displaced people contributed to spread of epidemics. Morbidity rate of acute infectious diseases was the highest in the big Polish cities, especially in Warsaw, Lodz, Lvov, Cracow and Vilnius. The Bureau of Chief Emergency Commissar for fighting against epidemics, which closely cooperated with other Polish sanitary institutions and international organisations, rendered the greatest service to the control of infectious diseases. Until the year 1924, the largest foci of diseases were controlled and their incidence decreased, what was possible after formation of sanitary posts along the eastern border of Poland, organisation of infectious disease hospitals, bath and disinfection centres in the country, and implementation of protective vaccinations.
Evaluating Thin Client Computers for Use by the Polish Army
2006-06-01
43 Figure 15. Annual Electricity Cost and Savings for 5 to 100 Users (source: Thin Client Computing...50 percent in hard costs in the first year of thin client network deployment.20 However, the greatest savings come from the reduction in soft costs ...resources from both the classrooms and home. The thin client solution increased the reliability of the IT infrastructure and resulted in cost savings
Food additives used in meat processing according to the Polish and European Union legislation.
Uradziński, J; Weiner, M
2003-01-01
This paper presents the legal regulations related to the use of food additives in meat production in Poland and the European Union. The Polish legal definition of food additives is given as well as the classification of permitted food additives added to food and stimulants by their technological function. In addition, a definition of processing aids in the food industry is included. It shows that Polish legislation includes food additives used to ensure or improve food nutritional value, whereas in the EU legislation, these substances are not included in the list of food additives. Moreover, the Council Directives include food additive specific purity criteria, whereas the Polish regulations do not mention the legal regulations of this issue in practice. The European Union use mechanisms and procedures for the introduction of new food additives into internal markets as well as controlling the circulation of additives. The Polish legislation in practice, however, does not determine approval or methods for the introduction of new food additives to the market. Legal regulations on the monitoring of food additives no exist.
Ion beam figuring of Φ520mm convex hyperbolic secondary mirror
NASA Astrophysics Data System (ADS)
Meng, Xiaohui; Wang, Yonggang; Li, Ang; Li, Wenqing
2016-10-01
The convex hyperbolic secondary mirror is a Φ520-mm Zerodur lightweight hyperbolic convex mirror. Typically conventional methods like CCOS, stressed-lap polishing are used to manufacture this secondary mirror. Nevertheless, the required surface accuracy cannot be achieved through the use of conventional polishing methods because of the unpredictable behavior of the polishing tools, which leads to an unstable removal rate. Ion beam figuring is an optical fabrication method that provides highly controlled error of previously polished surfaces using a directed, inert and neutralized ion beam to physically sputter material from the optic surface. Several iterations with different ion beam size are selected and optimized to fit different stages of surface figure error and spatial frequency components. Before ion beam figuring, surface figure error of the secondary mirror is 2.5λ p-v, 0.23λ rms, and is improved to 0.12λ p-v, 0.014λ rms in several process iterations. The demonstration clearly shows that ion beam figuring can not only be used to the final correction of aspheric, but also be suitable for polishing the coarse surface of large, complex mirror.
Air-powder polishing on self-ligating brackets after clinical use: effects on debris levels.
Aragón, Mônica L S Castro; Lima, Leandro Santiago; Normando, David
2016-01-01
Debris buildup on brackets and arch surfaces is one of the main factors that can influence the intensity of friction between bracket and orthodontic wire. This study sought to evaluate the effect of air-powder polishing cleaning on debris levels of self-ligating ceramic brackets at the end of orthodontic treatment, compared to the behavior of conventional brackets. Debris levels were evaluated in metal conventional orthodontic brackets (n = 42) and ceramic self-ligating brackets (n = 42) on canines and premolars, arranged in pairs. There were brackets with and without air-powder polishing. At the end of orthodontic treatment, a hemiarch served as control and the contralateral hemiarch underwent prophylaxis with air-powder polishing. Debris buildup in bracket slots was assessed through images, and Wilcoxon test was used to analyze the results. The median debris levels were statistically lower in the conventional metal brackets compared to self-ligating ones (p = 0.02), regarding brackets not submitted to air-powder polishing. Polishing significantly reduced debris buildup to zero in both systems, without differences between groups. Ceramic self-ligating brackets have a higher debris buildup in comparison to conventional metal brackets in vivo, but prophylaxis with sodium bicarbonate jet was effective in reducing debris levels in self-ligating and also in conventional brackets.
Krassner, Ariye M.; Gartstein, Maria A.; Park, Curie; Dragan, Wojciech Ł.; Lecannelier, Felipe; Putnam, Samuel P.
2017-01-01
The present study examined toddler temperament across Chilean, South Korean, Polish, and US samples, providing an opportunity to examine both collectivist-individualist and East-West contrasts. The effect of culture on the three factor and 18 dimension scores provided by the Early Childhood Behavior Questionnaire were investigated. Results provide evidence of cross-cultural differences between the four samples. Chilean toddlers scored significantly higher than US, Polish, and South Korean children on the overall factor of Negative Affectivity, as well as higher than the Polish and South Korean samples on the Surgency factor. South Korean toddlers scored significantly higher on the factor of Effortful Control, and two related dimensions, than US, Polish, or Chilean samples. Results are discussed in terms of the apparent roles of individualism/collectivism and East-West distinctions in shaping temperament development. PMID:29333175
Krassner, Ariye M; Gartstein, Maria A; Park, Curie; Dragan, Wojciech Ł; Lecannelier, Felipe; Putnam, Samuel P
2017-01-01
The present study examined toddler temperament across Chilean, South Korean, Polish, and US samples, providing an opportunity to examine both collectivist-individualist and East-West contrasts. The effect of culture on the three factor and 18 dimension scores provided by the Early Childhood Behavior Questionnaire were investigated. Results provide evidence of cross-cultural differences between the four samples. Chilean toddlers scored significantly higher than US, Polish, and South Korean children on the overall factor of Negative Affectivity, as well as higher than the Polish and South Korean samples on the Surgency factor. South Korean toddlers scored significantly higher on the factor of Effortful Control, and two related dimensions, than US, Polish, or Chilean samples. Results are discussed in terms of the apparent roles of individualism/collectivism and East-West distinctions in shaping temperament development.
Effect of one-step polishing system on the color stability of nanocomposites.
Alawjali, S S; Lui, J L
2013-08-01
This study was to compare the effect of three different one-step polishing systems on the color stability of three different types of nanocomposites after immersion in coffee for one day and seven days and determine which nanocomposite material has the best color stability following polishing with each of the one-step polishing system. The nanocomposites tested were Tetric EvoCeram, Grandio and Herculite Précis. A total of 120 discs (40/nanocomposite, 8mm×2mm) were fabricated. Ten specimens for each nanocomposite cured under Mylar strips served as the control. The other specimens were polished with OptraPol, OneGloss and Occlubrush immersed in coffee (Nescafé) up to seven days. Color measurements were made with a spectrophotometer at baseline and after one and seven days. Two way repeated measure ANOVA, two way ANOVA and Bonferroni tests were used for statistical analyses (P<0.05). The immersion time was a significant factor in the discoloration of the nanocomposites. The effect of three one-step polishing systems on the color stability was also significant. The color change values of the materials cured against Mylar strips were the greatest. The lowest mean color change values were from the Occlubrush polished groups. The effect of the three different types of nanocomposite on the color change was significant. The highest color change values were with Tetric EvoCeram groups. The lowest color change values were with Herculite Précis groups. The color change of nanocomposite resins is affected by the type of composite, polishing procedure and the period of immersion in the staining agent. Copyright © 2012 Elsevier Ltd. All rights reserved.
Smoking characteristics of Polish immigrants in Dublin.
Kabir, Zubair; Clarke, Vanessa; Keogan, Sheila; Currie, Laura M; Zatonski, Witold; Clancy, Luke
2008-12-31
This study examined two main hypotheses: a) Polish immigrants' smoking estimates are greater than their Irish counterparts (b) Polish immigrants purchasing cigarettes from Poland smoke "heavier" (>/= 20 cigarettes a day) when compared to those purchasing cigarettes from Ireland. The study also set out to identify significant predictors of 'current' smoking (some days and everyday) among the Polish immigrants. Dublin residents of Polish origin (n = 1,545) completed a previously validated Polish questionnaire in response to an advertisement in a local Polish lifestyle magazine over 5 weekends (July-August, 2007). The Office of Tobacco Control telephone-based monthly survey data were analyzed for the Irish population in Dublin for the same period (n = 484). Age-sex adjusted smoking estimates were: 47.6% (95% Confidence Interval [CI]: 47.3%; 48.0%) among the Poles and 27.8% (95% CI: 27.2%; 28.4%) among the general Irish population (p < 0.001). Of the 57% of smokers (n = 345/606) who purchased cigarettes solely from Poland and the 33% (n = 198/606) who purchased only from Ireland, 42.6% (n = 147/345) and 41.4% (n = 82/198) were "heavy" smokers, respectively (p = 0.79). Employment (Odds Ratio [OR]: 2.89; 95% CI: 1.25-6.69), lower education (OR: 3.76; 95%CI: 2.46-5.74), and a longer stay in Ireland (>24 months) were significant predictors of current smoking among the Poles. An objective validation of the self-reported smoking history of a randomly selected sub-sample immigrant group, using expired carbon monoxide (CO) measurements, showed a highly significant correlation coefficient (r = 0.64) of expired CO levels with the reported number of cigarettes consumed (p < 0.0001). Polish immigrants' smoking estimates are higher than their Irish counterparts, and particularly if employed, with only primary-level education, and are overseas >2 years.
NASA Technical Reports Server (NTRS)
Vilnrotter, V.
2011-01-01
The potential development of large aperture ground?based "photon bucket" optical receivers for deep space communications has received considerable attention recently. One approach currently under investigation is to polish the aluminum reflector panels of 34?meter microwave antennas to high reflectance, and accept the relatively large spotsize generated by state of?the?art polished aluminum panels. Theoretical analyses of receiving antenna pointing, temporal synchronization and data detection have been addressed in previous papers. Here we describe the experimental effort currently underway at the Deep Space Network (DSN) Goldstone Communications Complex in California, to test and verify these concepts in a realistic operational environment. Two polished aluminum panels (a standard DSN panel polished to high reflectance, and a custom designed aluminum panel with much better surface quality) have been mounted on the 34 meter research antenna at Deep?Space Station 13 (DSS?13), and a remotely controlled CCD camera with a large CCD sensor in a weather?proof container has been installed next to the subreflector, pointed directly at the custom polished panel. The point?spread function (PSF) generated by the Vertex polished panel has been determined to be smaller than the sensor of the CCD camera, hence a detailed picture of the PSF can be obtained every few seconds, and the sensor array data processed to determine the center of the intensity distribution. In addition to estimating the center coordinates, expected communications performance can also been evaluated with the recorded data. The results of preliminary pointing experiments with the Vertex polished panel receiver using the planet Jupiter to simulate the PSF generated by a deep?space optical transmitter are presented and discussed in this paper.
Post Processing and Biological Evaluation of the Titanium Scaffolds for Bone Tissue Engineering.
Wysocki, Bartłomiej; Idaszek, Joanna; Szlązak, Karol; Strzelczyk, Karolina; Brynk, Tomasz; Kurzydłowski, Krzysztof J; Święszkowski, Wojciech
2016-03-15
Nowadays, post-surgical or post-accidental bone loss can be substituted by custom-made scaffolds fabricated by additive manufacturing (AM) methods from metallic powders. However, the partially melted powder particles must be removed in a post-process chemical treatment. The aim of this study was to investigate the effect of the chemical polishing with various acid baths on novel scaffolds' morphology, porosity and mechanical properties. In the first stage, Magics software (Materialise NV, Leuven, Belgium) was used to design a porous scaffolds with pore size equal to (A) 200 µm, (B) 500 µm and (C) 200 + 500 µm, and diamond cell structure. The scaffolds were fabricated from commercially pure titanium powder (CP Ti) using a SLM50 3D printing machine (Realizer GmbH, Borchen, Germany). The selective laser melting (SLM) process was optimized and the laser beam energy density in range of 91-151 J/mm³ was applied to receive 3D structures with fully dense struts. To remove not fully melted titanium particles the scaffolds were chemically polished using various HF and HF-HNO₃ acid solutions. Based on scaffolds mass loss and scanning electron (SEM) observations, baths which provided most uniform surface cleaning were proposed for each porosity. The pore and strut size after chemical treatments was calculated based on the micro-computed tomography (µ-CT) and SEM images. The mechanical tests showed that the treated scaffolds had Young's modulus close to that of compact bone. Additionally, the effect of pore size of chemically polished scaffolds on cell retention, proliferation and differentiation was studied using human mesenchymal stem cells. Small pores yielded higher cell retention within the scaffolds, which then affected their growth. This shows that in vitro cell performance can be controlled to certain extent by varying pore sizes.
Post Processing and Biological Evaluation of the Titanium Scaffolds for Bone Tissue Engineering
Wysocki, Bartłomiej; Idaszek, Joanna; Szlązak, Karol; Strzelczyk, Karolina; Brynk, Tomasz; Kurzydłowski, Krzysztof J.; Święszkowski, Wojciech
2016-01-01
Nowadays, post-surgical or post-accidental bone loss can be substituted by custom-made scaffolds fabricated by additive manufacturing (AM) methods from metallic powders. However, the partially melted powder particles must be removed in a post-process chemical treatment. The aim of this study was to investigate the effect of the chemical polishing with various acid baths on novel scaffolds’ morphology, porosity and mechanical properties. In the first stage, Magics software (Materialise NV, Leuven, Belgium) was used to design a porous scaffolds with pore size equal to (A) 200 µm, (B) 500 µm and (C) 200 + 500 µm, and diamond cell structure. The scaffolds were fabricated from commercially pure titanium powder (CP Ti) using a SLM50 3D printing machine (Realizer GmbH, Borchen, Germany). The selective laser melting (SLM) process was optimized and the laser beam energy density in range of 91–151 J/mm3 was applied to receive 3D structures with fully dense struts. To remove not fully melted titanium particles the scaffolds were chemically polished using various HF and HF-HNO3 acid solutions. Based on scaffolds mass loss and scanning electron (SEM) observations, baths which provided most uniform surface cleaning were proposed for each porosity. The pore and strut size after chemical treatments was calculated based on the micro-computed tomography (µ-CT) and SEM images. The mechanical tests showed that the treated scaffolds had Young’s modulus close to that of compact bone. Additionally, the effect of pore size of chemically polished scaffolds on cell retention, proliferation and differentiation was studied using human mesenchymal stem cells. Small pores yielded higher cell retention within the scaffolds, which then affected their growth. This shows that in vitro cell performance can be controlled to certain extent by varying pore sizes. PMID:28773323
NASA Astrophysics Data System (ADS)
Chao, Zhang; Shijie, Su; Yilin, Yang; Guofu, Wang; Chao, Wang
2017-11-01
Aiming at the static balance of the controllable pitch propeller (CPP), a high efficiency static balance method based on the double-layer structure of the measuring table and gantry robot is adopted to realize the integration of torque measurement and corrected polish for controllable pitch propeller blade. The control system was developed by Microsoft Visual Studio 2015, and a composite platform prototype was developed. Through this prototype, conduct an experiment on the complete process of torque measurement and corrected polish based on a 300kg class controllable pitch propeller blade. The results show that the composite platform can correct the static balance of blade with a correct, efficient and labor-saving operation, and can replace the traditional method on static balance of the blade.
Effect of different polishing systems on the surface roughness of nano-hybrid composites.
Patel, Brijesh; Chhabra, Naveen; Jain, Disha
2016-01-01
The study aimed to investigate the influence of different polishing systems on the surface roughness of nano-hybrid composite resins. Different shapes of polishing systems are available according to the site of work. To minimize variability, a new system with single shape is developed that can be utilized in both anterior as well as posterior teeth. Seventy composite discs were fabricated using Teflon well (10 mm × 3 mm). Two main group of nano-hybrid composite Group I - Filtek Z350 and Group II - Tetric N-Ceram were used (n = 35 for each group). Both groups were further divided into four subgroups. Subgroup a - OneGloss (n = 10), Subgroup b - PoGo (n = 10), Subgroup c - Sof-Lex spiral (n = 10), Subgroup d - Mylar strip (control, n = 5). Samples were polished according to the manufacturer's recommendations. Surface roughness test was performed using contact profilometer. The obtained data were analyzed using the one-way analysis of variance test. Tetric N-Ceram produced smoother surfaces than Filtek Z350 (P < 0.05). Mylar strip and "PoGo" created equally smooth surfaces, while significantly rougher surfaces were obtained after applications of "Sof-Lex spiral" and "OneGloss" (P < 0.05). Polishing ability of Tetric N-Ceram is better than Filtek Z350 XT. "PoGo" seems to be a better polishing system than "OneGloss" and "Sof-Lex Spiral."
Removing function model and experiments on ultrasonic polishing molding die
NASA Astrophysics Data System (ADS)
Huang, Qitai; Ni, Ying; Yu, Jingchi
2010-10-01
Low temperature glass molding technology is the main method on volume-producing high precision middle and small diameter optical cells in the future. While the accuracy of the molding die will effect the cell precision, so the high precision molding die development is one of the most important part of the low temperature glass molding technology. The molding die is manufactured from high rigid and crisp metal alloy, with the ultrasonic vibration character of high vibration frequency and concentrative energy distribution; abrasive particles will impact the rigid metal alloy surface with very high speed that will remove the material from the work piece. Ultrasonic can make the rigid metal alloy molding die controllable polishing and reduce the roughness and surface error. Different from other ultrasonic fabrication method, untouched ultrasonic polishing is applied on polish the molding die, that means the tool does not touch the work piece in the process of polishing. The abrasive particles vibrate around the balance position with high speed and frequency under the drive of ultrasonic vibration in the liquid medium and impact the workspace surface, the energy of abrasive particles come from ultrasonic vibration, while not from the direct hammer blow of the tool. So a nummular vibrator simple harmonic vibrates on an infinity plane surface is considered as a model of ultrasonic polishing working condition. According to Huygens theory the sound field distribution on a plane surface is analyzed and calculated, the tool removing function is also deduced from this distribution. Then the simple point ultrasonic polishing experiment is proceeded to certificate the theory validity.
Soft tissue adhesion of polished versus glazed lithium disilicate ceramic for dental applications.
Brunot-Gohin, C; Duval, J-L; Azogui, E-E; Jannetta, R; Pezron, I; Laurent-Maquin, D; Gangloff, S C; Egles, C
2013-09-01
Ceramics are widely used materials for prosthesis, especially in dental fields. Despite multiple biomedical applications, little is known about ceramic surface modifications and the resulting cell behavior at its contact. The aim of this study is to evaluate the biological response of polished versus glazed surface treatments on lithium disilicate dental ceramic. We studied a lithium disilicate ceramic (IPS e.max(®) Press, Ivoclar Vivadent) with 3 different surface treatments: raw surface treatment, hand polished surface treatment, and glazed surface treatment (control samples are Thermanox(®), Nunc). In order to evaluate the possible modulation of cell response at the surface of ceramic, we compared polished versus glazed ceramics using an organotypic culture model of chicken epithelium. Our results show that the surface roughness is not modified as demonstrated by equivalent Ra measurements. On the contrary, the contact angle θ in water is very different between polished (84°) and glazed (33°) samples. The culture of epithelial tissues allowed a very precise assessment of histocompatibility of these interfaces and showed that polished samples increased cell adhesion and proliferation as compared to glazed samples. Lithium disilicate polished ceramic provided better adhesion and proliferation than lithium disilicate glazed ceramic. Taken together, our results demonstrate for the first time, how it is possible to use simple surface modifications to finely modulate the adhesion of tissues. Our results will help dental surgeons to choose the most appropriate surface treatment for a specific clinical application, in particular for the ceramic implant collar. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Peak expiratory flow rate of children working in lock factories.
Singhal, S; Singhal, A; Singh, P N; Agarwal, D K; Gulati, R
2006-01-01
Peak expiratory flow rate (PEFR) of 106 children working in different units of lock factory was measured and compared with age and sex matched control group of same socio-economic status children. All the children worked for about ten hours per day. It was observed that there was a significant decrease in PEFR of children working in the different units of lock factories i.e. Hand press, Polishing, Lock fitting, Lock packing units as compared to control group (P>0.001). The reduction percentage of PEFR was maximum in children working in polishing unit (25.48%).
Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.
Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee
2013-09-01
Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.
Computer aided manufacturing for complex freeform optics
NASA Astrophysics Data System (ADS)
Wolfs, Franciscus; Fess, Ed; Johns, Dustin; LePage, Gabriel; Matthews, Greg
2017-10-01
Recently, the desire to use freeform optics has been increasing. Freeform optics can be used to expand the capabilities of optical systems and reduce the number of optics needed in an assembly. The traits that increase optical performance also present challenges in manufacturing. As tolerances on freeform optics become more stringent, it is necessary to continue to improve methods for how the grinding and polishing processes interact with metrology. To create these complex shapes, OptiPro has developed a computer aided manufacturing package called PROSurf. PROSurf generates tool paths required for grinding and polishing freeform optics with multiple axes of motion. It also uses metrology feedback for deterministic corrections. ProSurf handles 2 key aspects of the manufacturing process that most other CAM systems struggle with. The first is having the ability to support several input types (equations, CAD models, point clouds) and still be able to create a uniform high-density surface map useable for generating a smooth tool path. The second is to improve the accuracy of mapping a metrology file to the part surface. To perform this OptiPro is using 3D error maps instead of traditional 2D maps. The metrology error map drives the tool path adjustment applied during processing. For grinding, the error map adjusts the tool position to compensate for repeatable system error. For polishing, the error map drives the relative dwell times of the tool across the part surface. This paper will present the challenges associated with these issues and solutions that we have created.
Pinto, Gustavo Da Col dos Santos; Dias, Kleber Campioni; Cruvinel, Diogo Rodrigues; Garcia, Lucas da Fonseca Roberti; Consani, Simonides; Pires-De-Souza, Fernanda de Carvalho Panzeri
2013-01-01
To assess the influence of finishing/polishing procedure on color stability (ΔE ) and surface roughness (R(a)) of composites (Heliomolar and Tetric - color A2) submitted to accelerated artificial aging (AAA). Sixty test specimens were made of each composite (12 mm × 2 mm) and separated into six groups (n = 10), according to the type of finishing/polishing to which they were submitted: C, control; F, tip 3195 F; FF, tip 3195 FF; FP, tip 3195 F + diamond paste; FFP, tip 3195 FF + diamond paste; SF, Sof-Lex discs. After polishing, controlled by an electromechanical system, initial color (spectrophotometer PCB 6807 BYK GARDNER) and R(a) (roughness meter Surfcorder SE 1700, cut-off 0.25 mm) readings were taken. Next, the test specimens were submitted to the AAA procedure (C-UV Comexim) for 384 hours, and at the end of this period, new color readings and R(a) were taken. Statistical analysis [2-way analysis of variance (ANOVA), Bonferroni, P < 0.05] showed that all composites demonstrated ΔE alteration above the clinically acceptable limits, with the exception of Heliomolar composite in FP. The greatest ΔE alteration occurred for Tetric composite in SF (13.38 ± 2.10) statistically different from F and FF (P < 0.05). For R(a), Group F showed rougher samples than FF with statistically significant difference (P < 0.05). In spite of the surface differences, the different finishing/polishing procedures were not capable of providing color stability within the clinically acceptable limits.
Researchers' Expectations Regarding the Online Presence of Academic Libraries
ERIC Educational Resources Information Center
Mierzecka, Anna; Kisilowska, Malgorzata; Suminas, Andrius
2017-01-01
The article reports the results of a survey conducted among the Polish and Lithuanian academics concerning their information needs and expectations regarding academic library websites. The survey was realized using the technique of Computer-Assisted Web Interviewing (CAWI) on a group of scholars representing sciences and humanities or social…
Project Triunfe, 1987-88. OREA Report.
ERIC Educational Resources Information Center
Berney, Tomi D.; Watson, Heriberto
In its fifth year of funding, Project TRIUNFE served 413 limited-English-proficient speakers of Spanish, French/Haitian Creole, Asian languages, and Polish at John Jay High School in Brooklyn. The program's aim was to supplement the high school's transitional bilingual education program, emphasizing computer instruction, partial English immersion,…
Wagner, Monica; Shafer, Valerie L.; Martin, Brett; Steinschneider, Mitchell
2013-01-01
The effect of exposure to the contextual features of the /pt/ cluster was investigated in native-English and native-Polish listeners using behavioral and event-related potential (ERP) methodology. Both groups experience the /pt/ cluster in their languages, but only the Polish group experiences the cluster in the context of word onset examined in the current experiment. The /st/ cluster was used as an experimental control. ERPs were recorded while participants identified the number of syllables in the second word of nonsense word pairs. The results found that only Polish listeners accurately perceived the /pt/ cluster and perception was reflected within a late positive component of the ERP waveform. Furthermore, evidence of discrimination of /pt/ and /pǝt/ onsets in the neural signal was found even for non-native listeners who could not perceive the difference. These findings suggest that exposure to phoneme sequences in highly specific contexts may be necessary for accurate perception. PMID:22867752
X-ray Computed Tomography Assessment of Air Void Distribution in Concrete
NASA Astrophysics Data System (ADS)
Lu, Haizhu
Air void size and spatial distribution have long been regarded as critical parameters in the frost resistance of concrete. In cement-based materials, entrained air void systems play an important role in performance as related to durability, permeability, and heat transfer. Many efforts have been made to measure air void parameters in a more efficient and reliable manner in the past several decades. Standardized measurement techniques based on optical microscopy and stereology on flat cut and polished surfaces are widely used in research as well as in quality assurance and quality control applications. Other more automated methods using image processing have also been utilized, but still starting from flat cut and polished surfaces. The emergence of X-ray computed tomography (CT) techniques provides the capability of capturing the inner microstructure of materials at the micrometer and nanometer scale. X-ray CT's less demanding sample preparation and capability to measure 3D distributions of air voids directly provide ample prospects for its wider use in air void characterization in cement-based materials. However, due to the huge number of air voids that can exist within a limited volume, errors can easily arise in the absence of a formalized data processing procedure. In this study, air void parameters in selected types of cement-based materials (lightweight concrete, structural concrete elements, pavements, and laboratory mortars) have been measured using micro X-ray CT. The focus of this study is to propose a unified procedure for processing the data and to provide solutions to deal with common problems that arise when measuring air void parameters: primarily the reliable segmentation of objects of interest, uncertainty estimation of measured parameters, and the comparison of competing segmentation parameters.
Optical properties and light irradiance of monolithic zirconia at variable thicknesses.
Sulaiman, Taiseer A; Abdulmajeed, Aous A; Donovan, Terrence E; Ritter, André V; Vallittu, Pekka K; Närhi, Timo O; Lassila, Lippo V
2015-10-01
The aims of this study were to: (1) estimate the effect of polishing on the surface gloss of monolithic zirconia, (2) measure and compare the translucency of monolithic zirconia at variable thicknesses, and (3) determine the effect of zirconia thickness on irradiance and total irradiant energy. Four monolithic partially stabilized zirconia (PSZ) brands; Prettau® (PRT, Zirkonzahn), Bruxzir® (BRX, Glidewell), Zenostar® (ZEN, Wieland), Katana® (KAT, Noritake), and one fully stabilized zirconia (FSZ); Prettau Anterior® (PRTA, Zirkonzahn) were used to fabricate specimens (n=5/subgroup) with different thicknesses (0.5, 0.7, 1.0, 1.2, 1.5, and 2.0mm). Zirconia core material ICE® Zircon (ICE, Zirkonzahn) was used as a control. Surface gloss and translucency were evaluated using a reflection spectrophotometer. Irradiance and total irradiant energy transmitted through each specimen was quantified using MARC® Resin Calibrator. All specimens were then subjected to a standardized polishing method and the surface gloss, translucency, irradiance, and total irradiant energy measurements were repeated. Statistical analysis was performed using two-way ANOVA and post-hoc Tukey's tests (p<0.05). Surface gloss was significantly affected by polishing (p<0.05), regardless of brand and thickness. Translucency values ranged from 5.65 to 20.40 before polishing and 5.10 to 19.95 after polishing. The ranking from least to highest translucent (after polish) was: BRX=ICE=PRT
Smoking characteristics of Polish immigrants in Dublin
Kabir, Zubair; Clarke, Vanessa; Keogan, Sheila; Currie, Laura M; Zatonski, Witold; Clancy, Luke
2008-01-01
Background This study examined two main hypotheses: a) Polish immigrants' smoking estimates are greater than their Irish counterparts (b) Polish immigrants purchasing cigarettes from Poland smoke "heavier" (≥ 20 cigarettes a day) when compared to those purchasing cigarettes from Ireland. The study also set out to identify significant predictors of 'current' smoking (some days and everyday) among the Polish immigrants. Methods Dublin residents of Polish origin (n = 1,545) completed a previously validated Polish questionnaire in response to an advertisement in a local Polish lifestyle magazine over 5 weekends (July–August, 2007). The Office of Tobacco Control telephone-based monthly survey data were analyzed for the Irish population in Dublin for the same period (n = 484). Results Age-sex adjusted smoking estimates were: 47.6% (95% Confidence Interval [CI]: 47.3%; 48.0%) among the Poles and 27.8% (95% CI: 27.2%; 28.4%) among the general Irish population (p < 0.001). Of the57% of smokers (n = 345/606) who purchased cigarettes solely from Poland and the 33% (n = 198/606) who purchased only from Ireland, 42.6% (n = 147/345) and 41.4% (n = 82/198) were "heavy" smokers, respectively (p = 0.79). Employment (Odds Ratio [OR]: 2.89; 95% CI: 1.25–6.69), lower education (OR: 3.76; 95%CI: 2.46–5.74), and a longer stay in Ireland (>24 months) were significant predictors of current smoking among the Poles. An objective validation of the self-reported smoking history of a randomly selected sub-sample immigrant group, using expired carbon monoxide (CO) measurements, showed a highly significant correlation coefficient (r = 0.64) of expired CO levels with the reported number of cigarettes consumed (p < 0.0001). Conclusion Polish immigrants' smoking estimates are higher than their Irish counterparts, and particularly if employed, with only primary-level education, and are overseas >2 years. PMID:19117510
Kocaagaoglu, H; Aslan, T; Gürbulak, A; Albayrak, H; Taşdemir, Z; Gumus, H
2017-05-01
Different polishing kits may have different effects on the composite resin surfaces. The aim of this study was to evaluate the surface roughness and color stability of four different composites which was applied different polishing technique. Thirty specimens were made for each composite resin group (nanohybrid, GrandioSo-GS; nanohybrid, Clearfil Majesty Esthetic-CME; hybrid, Valux Plus-VP; micro-hybrid, Ruby Comp-RC; [15 mm in diameter and 2 mm height]), with the different monomer composition and particle size from a total of 120 specimens. Each composite group was divided into three subgroups (n = 10). The first subgroup of the each composite subgroups served as control (C) and had no surface treatment. The second subgroup of the each composite resin groups was polished with finishing discs (Bisco Finishing Discs; Bisco Inc., Schaumburg, IL, USA). The third subgroup of the each composite resin was polished with polishing wheel (Enhance and PoGo, Dentsply, Konstanz, Germany). The surface roughness and the color differences measurement of the specimens were made and recorded. The data were compared using Kruskal-Wallis test, and regression analysis was used in order to examine the correlation between surface roughness and color differences of the specimens (α = 0.05). The Kruskal-Wallis test indicated significant difference among the composite resins in terms of ΔE (P < 0.05), and there was no statistically significant difference among composite resins in terms of surface roughness (P > 0.05). Result of the regression analysis indicated statistically significant correlation between Ra and ΔE values (P < 0.05, r2 = 0.74). The findings of the present study have clinical relevance in the choice of polishing kits used.
Abrasive wear of resin composites as related to finishing and polishing procedures.
Turssi, Cecilia P; Ferracane, Jack L; Serra, Mônica C
2005-07-01
Finishing and polishing procedures may cause topographical changes and introduce subsurface microcracks in dental composite restoratives. Since both of these effects may contribute toward the kinetics of wear, the purpose of this study was to assess and correlate the wear and surface roughness of minifilled and nanofilled composites finished and polished by different methods. Specimens (n=10) made of a minifilled and a nanofilled composite were finished and polished with one of the four sequences: (1) tungsten carbide burs plus Al(2)O(3)-impregnated brush (CbBr) or (2) tungsten carbide burs plus diamond-impregnated cup (CbCp), (3) diamond burs plus brush (DmBr) or (4) diamond burs plus cup (DmCp). As a control, abrasive papers were used. After surface roughness had been quantified, three-body abrasion was simulated using the OHSU wear machine. The wear facets were then scanned to measure wear depth and post-testing roughness. All sets of data were subjected to ANOVA and Tukey's tests (alpha=0.05). Pearson's correlation test was applied to check for the existence of a relationship between pre-testing roughness and wear. Significantly smoother surfaces were attained with the sequences CbBr and CbCp, whereas DmCp yielded the roughest surface. Regardless of the finishing/polishing technique, the nanofilled composite exhibited the lowest pre-testing roughness and wear. There was no correlation between the surface roughness achieved after finishing/polishing procedures and wear (p=0.3899). Nano-sized materials may have improved abrasive wear resistance over minifilled composites. The absence of correlation between wear and surface roughness produced by different finishing/polishing methods suggests that the latter negligibly influences material loss due to three-body abrasion.
Bacáková, L; Starý, V; Kofronová, O; Lisá, V
2001-03-15
Carbon fiber-reinforced carbon composites (CFRC) are considered to be promising materials for orthopedic and dental surgery. Their mechanical properties can be tailored to be similar to those of bone, and their chemical composition (close to pure carbon) promises that they will be tolerated well by the surrounding tissue. In this study, CFRC composites were fabricated from phenolic resin and unidirectionally oriented Torayca carbon fibers by carbonization (1000 degrees C) and graphitization (2500 degrees C). The material then was cut with a diamond saw into sheets of 8 x 10 x 3 mm, and the upper surface was polished by colloidal SiO2 and/or covered with a carbon-titanium (C:Ti) layer (3.3 microm) using the plasma-enhanced physical vapor deposition method. Three different kinds of modified samples were prepared: polished only, covered only, and polished + covered. Untreated samples served as a control. The surface roughness of these samples, measured by a Talysurf profilometer, decreased significantly after polishing but usually did not decrease after coating with a C:Ti layer. On all three modified surfaces, human osteoblast-like cells of the MG63 line and rat vascular smooth muscle cells (both cultured in a Dulbecco's minimum essential medium with 10% fetal bovine serum) adhered at higher numbers (by 21-87% on day 1 after seeding) and exhibited a shorter population doubling time (by 13-40%). On day 4 after seeding, these cells attained higher population densities (by 61-378%), volume (by 18-37%), and protein content (by 16-120%). These results were more pronounced in VSMC than in MG63 cells and in both groups of C:Ti-covered samples than in the polished only samples. The release of carbon particles from the CFRC composites was significantly decreased--by 8 times in the polished only, 24 times in the covered only, and 42 times in the polished + covered samples. These results show that both polishing and carbon-titanium covering significantly improve the biocompatibility of CFRC composites in vitro, especially when these two modifications are combined.
Mechanistic, kinetic, and processing aspects of tungsten chemical mechanical polishing
NASA Astrophysics Data System (ADS)
Stein, David
This dissertation presents an investigation into tungsten chemical mechanical polishing (CMP). CMP is the industrially predominant unit operation that removes excess tungsten after non-selective chemical vapor deposition (CVD) during sub-micron integrated circuit (IC) manufacture. This work explores the CMP process from process engineering and fundamental mechanistic perspectives. The process engineering study optimized an existing CMP process to address issues of polish pad and wafer carrier life. Polish rates, post-CMP metrology of patterned wafers, electrical test data, and synergy with a thermal endpoint technique were used to determine the optimal process. The oxidation rate of tungsten during CMP is significantly lower than the removal rate under identical conditions. Tungsten polished without inhibition during cathodic potentiostatic control. Hertzian indenter model calculations preclude colloids of the size used in tungsten CMP slurries from indenting the tungsten surface. AFM surface topography maps and TEM images of post-CMP tungsten do not show evidence of plow marks or intergranular fracture. Polish rate is dependent on potassium iodate concentration; process temperature is not. The colloid species significantly affects the polish rate and process temperature. Process temperature is not a predictor of polish rate. A process energy balance indicates that the process temperature is predominantly due to shaft work, and that any heat of reaction evolved during the CMP process is negligible. Friction and adhesion between alumina and tungsten were studied using modified AFM techniques. Friction was constant with potassium iodate concentration, but varied with applied pressure. This corroborates the results from the energy balance. Adhesion between the alumina and the tungsten was proportional to the potassium iodate concentration. A heuristic mechanism, which captures the relationship between polish rate, pressure, velocity, and slurry chemistry, is presented. In this mechanism, the colloid reacts with the chemistry of the slurry to produce active sites. These active sites become inactive by removing tungsten from the film. The process repeats when then inactive sites are reconverted to active sites. It is shown that the empirical form of the heuristic mechanism fits all of the data obtained. The mechanism also agrees with the limiting cases that were investigated.
Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.
Zhai, Ke; He, Qing; Li, Liang; Ren, Yi
2017-09-01
Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head was calculated and designed. Silicon wafers are polished by megasonic assisted chemical mechanical polishing and traditional chemical mechanical polishing respectively, both coarse polishing and precision polishing experiments were carried out. With the use of megasonic vibration, the surface roughness values Ra reduced from 22.260nm to 17.835nm in coarse polishing, and the material removal rate increased by approximately 15-25% for megasonic assisted chemical mechanical polishing relative to traditional chemical mechanical polishing. Average Surface roughness values Ra reduced from 0.509nm to 0.387nm in precision polishing. The results show that megasonic assisted chemical mechanical polishing is a feasible method to improve polishing efficiency and surface quality. The material removal and finishing mechanisms of megasonic vibration assisted polishing are investigated too. Copyright © 2017 Elsevier B.V. All rights reserved.
Effect of different polishing systems on the surface roughness of nano-hybrid composites
Patel, Brijesh; Chhabra, Naveen; Jain, Disha
2016-01-01
Objective: The study aimed to investigate the influence of different polishing systems on the surface roughness of nano-hybrid composite resins. Background: Different shapes of polishing systems are available according to the site of work. To minimize variability, a new system with single shape is developed that can be utilized in both anterior as well as posterior teeth. Materials and Methods: Seventy composite discs were fabricated using Teflon well (10 mm × 3 mm). Two main group of nano-hybrid composite Group I — Filtek Z350 and Group II — Tetric N-Ceram were used (n = 35 for each group). Both groups were further divided into four subgroups. Subgroup a — OneGloss (n = 10), Subgroup b - PoGo (n = 10), Subgroup c — Sof-Lex spiral (n = 10), Subgroup d - Mylar strip (control, n = 5). Samples were polished according to the manufacturer's recommendations. Surface roughness test was performed using contact profilometer. The obtained data were analyzed using the one-way analysis of variance test. Result: Tetric N-Ceram produced smoother surfaces than Filtek Z350 (P < 0.05). Mylar strip and “PoGo” created equally smooth surfaces, while significantly rougher surfaces were obtained after applications of “Sof-Lex spiral” and “OneGloss” (P < 0.05). Conclusion: Polishing ability of Tetric N-Ceram is better than Filtek Z350 XT. “PoGo” seems to be a better polishing system than “OneGloss” and “Sof-Lex Spiral.” PMID:26957791
Reduced cost and improved figure of sapphire optical components
NASA Astrophysics Data System (ADS)
Walters, Mark; Bartlett, Kevin; Brophy, Matthew R.; DeGroote Nelson, Jessica; Medicus, Kate
2015-10-01
Sapphire presents many challenges to optical manufacturers due to its high hardness and anisotropic properties. Long lead times and high prices are the typical result of such challenges. The cost of even a simple 'grind and shine' process can be prohibitive. The high precision surfaces required by optical sensor applications further exacerbate the challenge of processing sapphire thereby increasing cost further. Optimax has demonstrated a production process for such windows that delivers over 50% time reduction as compared to traditional manufacturing processes for sapphire, while producing windows with less than 1/5 wave rms figure error. Optimax's sapphire production process achieves significant improvement in cost by implementation of a controlled grinding process to present the best possible surface to the polishing equipment. Following the grinding process is a polishing process taking advantage of chemical interactions between slurry and substrate to deliver excellent removal rates and surface finish. Through experiments, the mechanics of the polishing process were also optimized to produce excellent optical figure. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. Through specially developed polishing slurries, the peak-to-valley figure error of spherical sapphire parts is reduced by over 80%.
Torabi, Kianoosh; Rasaeipour, Sasan; Khaledi, Amir Alireza; Vojdani, Mahroo; Ghodsi, Safoura
2014-05-01
Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied. The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness of the polished fiber reinforced composite (FRC), overglazed, autoglazed, or polished ceramic samples. Twenty standardized cylindrical specimens were made of each of the following groups: over-glazed, autoglazed, polished porcelain and also FRC. The test specimens exposed to the CP 38%, 15 minutes, twice a day for 2 weeks according to the manufacturer's recommendation. Six samples from each group were selected randomly to form negative controls. Surface roughness measurements (Ra, micrometer) for baseline, test and control specimens were performed by use of a profilometer. Paired t-test, Mann-Whitney test, and Kruskal-Wallis test were used for statistical analyses. The data showed that bleaching with CP 38% significantly increased the surface roughness of all the test samples (p < 0.05). The type of surface preparation caused significant differences between the susceptibility of porcelain subgroups to bleaching (p < 0.05). The polished porcelain specimens showed the highest changes after bleaching. CP 38% significantly increases the surface roughness of the porcelains and FRC. The type of surface condition affects the amenability of the porcelain surface to the bleaching agent. Glazed porcelains were more resistant to roughness than the polished porcelains and also the composite. Roughening of porcelain and FRC occur following bleaching procedure. No special surface preparation of indirect esthetic restorative materials can completely preserve these materials from adverse effects of bleaching agents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakurai, Tatsuyuki; Kohmura, Yoshiki; Takeuchi, Akihisa
2007-01-19
When beryllium is used in transmission X-ray optical elements for spatially coherent beams, speckles are usually observed in the transmission images. These speckles seem to be caused by defects either inside or on the surface of beryllium foil. We measured highly polished beryllium foil using two methods, X-ray computed tomography and X-ray shearing interferometry. The results indicate that observed speckle pattern is caused by many voids inside beryllium or inner low-density regions.
Mohammadi-Bassir, Mahshid; Babasafari, Mansoure; Rezvani, Mohammad Bagher; Jamshidian, Mahdieh
2017-11-01
Limited information is available for the best polishing systems and methods to obtain minimally abrasive monolithic zirconia surfaces after contouring and occlusal adjustment. The purpose of this in vitro study was to evaluate the effect of grinding and polishing procedures on the flexural strength, quality and quantity of surface roughness, topography, and phase transformation of a zirconia-based ceramic system. Fifty bar-shaped yttrium-stabilized zirconium oxide specimens (20×4×2 mm) were cut from presintered zirconia blanks. The specimens were wet-polished and divided into 5 groups (n=10): standard polishing without any surface treatment (group SP); grinding with a diamond rotary instrument (group Gr); grinding with a diamond rotary instrument (DRI) and over-glazing (group Gl); grinding with a DRI and polishing with an intraoral zirconia polishing kit in a 2-step procedure (group BP); and grinding with a DRI and polishing with an intraoral polishing kit (group MP). The Ra and Rz surface roughness values (μm) were measured with a profilometer. One specimen of each group was subjected to x-ray diffraction (XRD) to estimate the monoclinic phase and evaluated using scanning electron microscopy (SEM) for surface topography. The 3-point flexural strength of the bars was measured in a universal testing machine at a crosshead speed of 0.5 mm/min. The mean flexural strength (MPa) and surface roughness values were calculated, and the results were analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Statistically significant differences were noted among the experimental groups for Ra, Rz (P<.001), and flexural strength values (P<.001). The highest Ra and Rz values were found in group Gr (P<.001) and the lowest in group Gl, which were significantly lower than the values in group Gr (P<.001). The 2 polishing systems (BP and MP) were not significantly different in terms of Ra and Rz values (P=.755 for Ra and P=.319 for Rz). The highest flexural strength was found in group Gr (283.35 ±49.85 MPa) without significant differences from those of MP and BP (P=.958 for BP and P=.404 for MP). The lowest flexural strength was found in Gl, which had no significant differences from those of the control group (P=1.000). In XRD the monoclinic phase was observed in Gr (26%), BP (24%), and MP (23%) groups. However, groups Gl and SP did not have any monoclinic phase. SEM showed deep unidirectional scratches after grinding that were smoothened by glazing and polishing. Roughness increased significantly after grinding, but polishing and glazing similarly diminished it. Glazing after grinding significantly decreased the flexural strength values, but polishing did not. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Vilnrotter, Victor A.
2012-01-01
Initial optical communications experiments with a Vertex polished aluminum panel have been described. The polished panel was mounted on the main reflector of the DSN's research antenna at DSS-13. The PSF was recorded via remotely controlled digital camera mounted on the subreflector structure. Initial PSF generated by Jupiter showed significant tilt error and some mechanical deformation. After upgrades, the PSF improved significantly, leading to much better concentration of light. Communications performance of the initial and upgraded panel structure were compared. After the upgrades, simulated PPM symbol error probability decreased by six orders of magnitude. Work is continuing to demonstrate closed-loop tracking of sources from zenith to horizon, and better characterize communications performance in realistic daytime background environments.
Conservative restoration of a traumatically involved central incisor.
Bassett, Joyce
2012-04-01
The use of a direct composite material known for excellent polishability, polish retention, and wear resistance is described in this case of a fractured central incisor restoration. The method used enabled the clinician to conserve tooth structure and maintain full control of the outcome while creating an esthetically imperceptible, reliable, and durable restoration for a young male patient. Emphasized in this case are the techniques of layering, contouring, and polishing of a nanocomposite used to maximize esthetics and meet patient expectations. To further ensure imperceptibility, the author recommends first facilitating color shade selection for both body and dentin-especially in two-shade or multiple-shade restorations-by placing the composite in its planned area of the restoration and curing it in its proper thickness to allow a preview and recipe map.
Characterizing optical polishing pitch
NASA Astrophysics Data System (ADS)
Varshneya, Rupal; DeGroote, Jessica E.; Gregg, Leslie L.; Jacobs, Stephen D.
2003-05-01
Characterization data for five experimental optical polishing pitch products were compared to those for corresponding standard commercial optical polishing pitches. The experimental pitches were tested for three physical properties: hardness, viscosity at 90°C, and softening point. A Shore A Durometer test was used to measure hardness. Viscosity data were collected using a Stony Brook Scientific falling needle viscometer. Softening point was determined using the ASTM D3104-97 method. Results demonstrate that the softest and the hardest batches of the experimental grades of optical pitch are comparable to the industry-accepted standards, while the other grades of pitch are not. The experimental methodology followed in this research may allow opticians to rapidly compare different brands of pitch to help identify batch-to-batch differences and control pitch quality before use.
Characterizing optical polishing pitch
NASA Astrophysics Data System (ADS)
Varshneya, Rupal
2003-05-01
Characterization data for five experimental optical polishing pitch products were compared to those for corresponding standard commercial optical polishing pitches. The experimental pitches were tested for three physical properties: hardness, viscosity at 90°C, and softening point. A Shore A Durometerl test was used to measure hardness. Viscosity data were collected using a Stony Brook Scientific' falling needle viscometer. Softening point was determined using the ASTM D3104-97 method. Results demonstrate that the softest and the hardest batches of the experimental grades of optical pitch are comparable to the industry-accepted standards, while the other grades of pitch are not. The experimental methodology followed in this research may allow opticians to rapidly compare different brands of pitch to help identify batch- to- batch differences and control pitch quality before use.
First Giant Mirror for the ESO VLT Ready at REOSC
NASA Astrophysics Data System (ADS)
1995-11-01
The REOSC Contract In 1989, the European Southern Observatory (ESO), the European Organisation for Astronomy, awarded to REOSC, a subsidiary of the SFIM Group and located in Saint Pierre du Perray (France), a comprehensive contract for the polishing of four 8.2-metre diameter mirrors for the unit telescopes of the ESO Very Large Telescope (VLT) project. These mirrors are the largest ever manufactured and polished. This contract comprises not only the polishing and high-precision optical testing of each giant mirror, but also the safe condition of transportation of the blanks which were manufactured by Schott Glaswerke in Mainz (Germany). In order to fulfill the contract, REOSC conceived, built and equipped a novel, high-tech workshop which would allow to polish and test the mirrors, each of which has a surface area of more than 50 square metres. First 8.2-Metre Mirror is Ready and within Specifications The REOSC polishing facility for giant mirrors was built in Saint Pierre du Perray, just south of Paris. It is equipped with two machines: one for grinding and the other for polishing the mirrors, and both with 150-actuator systems that support the thin and flexible mirrors. All equipment is computer controlled. State-of-the-art interferometers probe the accuracy of the mirror surface as the polishing proceeds; they are installed at the top level of the facility in a 30-metre high tower, at the centre of the mirror's radius of curvature. The success of the work at REOSC is now evident by the fact that careful measurements of the first mirror earlier this month have shown that the final optical surface is correct to within 0.00005 millimetres. For illustration, this corresponds to an accuracy of only 1 millimetre deviation over a surface with a diameter of 165 kilometres (equivalent to the entire Paris area)! ESO Receives the First VLT Mirror After having been carefully placed in a special transport box designed by REOSC, the first mirror blank, weighing 23.5 tons and with a replacement value of about 20 million DEM, was transported from Mainz to Saint Pierre du Perray in July 1993. The shaping and polishing phases lasted two years and were completed in October 1995. After one month's hard work, dedicated to optical and mechanical verifications by ESO and REOSC, the mirror's various characteristics have now been found to be in accordance with the contract specifications. Following the technical acceptance, the first mirror was re-installed in its transport container on November 13, 1995. It will thereafter be formally handed over to ESO during a ceremony at REOSC on Tuesday, November 21, 1995. The mirror will be stored at the REOSC facility until its future departure to ESO's VLT Observatory on Cerro Paranal, a 2650 m high summit in the Andean Cordillera in northern Chile. Here it will be installed in the first VLT unit telescope, soon after the assembly of the mechanical parts has been completed. Future Plans at REOSC The polishing of the second VLT mirror, as well as the grinding of the third mirror which was transported from Mainz to Saint Pierre du Perray at the beginning of October 1995, have already started. The transport of the fourth blank will take place in March 1996. With the construction, in a subsequent phase, of a workshop of more than 6000 square metres and mostly dedicated to space and astronomy, the SFIM group will have invested more than 50 million French Francs at the Saint Pierre du Perray site alone. The group is also involved in the contract related to the actuator support system; this is a clear indication of its determination to maintain its position within this scientific-technological market. In addition to the ESO VLT mirrors, REOSC will also polish the two 8.2-metre diameter mirrors of the Gemini programme of the Association of Universities for Research in Astronomy (AURA) in the United States. This important work was entrusted REOSC, following an international call for tenders, in which also US firms participated. How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../). ESO Press Photos may be reproduced, if credit is given to the European Southern Observatory.
NASA Astrophysics Data System (ADS)
Zhang, Huifang; Yang, Minghong; Xu, Xueke; Wu, Lunzhe; Yang, Weiguang; Shao, Jianda
2017-10-01
The surface figure control of the conventional annular polishing system is realized ordinarily by the interaction between the conditioner and the lap. The surface profile of the pitch lap corrected by the marble conditioner has been measured and analyzed as a function of kinematics, loading conditions, and polishing time. The surface profile measuring equipment of the large lap based on laser alignment was developed with the accuracy of about 1μm. The conditioning mechanism of the conditioner is simply determined by the kinematics and fully fitting principle, but the unexpected surface profile deviation of the lap emerged frequently due to numerous influencing factors including the geometrical relationship, the pressure distribution at the conditioner/lap interface. Both factors are quantitatively evaluated and described, and have been combined to develop a spatial and temporal model to simulate the surface profile evolution of pitch lap. The simulations are consistent with the experiments. This study is an important step toward deterministic full-aperture annular polishing, providing a beneficial guidance for the surface profile correction of the pitch lap.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, D. D., E-mail: dandan.wang@globalfoundries.com; Huang, Y. M.; Tan, P. K.
2015-12-15
Presently two major limiting factors are hindering the failure analysis (FA) development during the semiconductor manufacturing process and technology improvement: (1) Impossibility of manual polishing on the edge dies due to the amenability of layer peeling off; (2) Abundant demand of multi-locations FA, especially focusing different levels of layers simultaneously. Aiming at resolving these limitations, here we demonstrate two unique high precision polishing methods by using focused ion beam (FIB) technique. One is the vertical top down chemical etching at the aimed location; the other one is the planar top down slicing. Using the FIB for delayering not only solvesmore » these problems mentioned above, but also offers significant advantages over physical planar polishing methods such as: (1) having a better control of the delayering progress, (2) enabling precisely milling at a region of interest, (3) providing the prevention of over-delayering and (4) possessing capability to capture images at the region of interest simultaneously and cut into the die directly to expose the exact failure without damaging other sections of the specimen.« less
Surface roughness of novel resin composites polished with one-step systems.
Ergücü, Z; Türkün, L S
2007-01-01
This study: 1) analyzed the surface roughness of five novel resin composites that contain nanoparticles after polishing with three different one-step systems and 2) evaluated the effectiveness of these polishers and their possible surface damage using scanning electron microscope (SEM) analysis. The resin composites evaluated in this study include CeramX, Filtek Supreme XT, Grandio, Premise and Tetric EvoCeram. A total of 100 discs (20/resin composites, 10 x 2 mm) were fabricated. Five specimens/resin composites cured under Mylar strips served as the control. The samples were polished for 30 seconds with PoGo, OptraPol and One Gloss discs at 15,000 rpm using a slow speed handpiece. The surfaces were tested for roughness (Ra) with a surface roughness tester and examined with SEM. One-way ANOVA was used for statistical analysis (p = 0.05). For all the composites tested, differences between the polishing systems were found to be significant (p < 0.05). For Filtek Supreme XT, Mylar and PoGo created equally smooth surfaces, while significantly rougher surfaces were obtained after OptraPol and One Gloss applications. For Grandio, Mylar and PoGo created equally smooth surfaces, while OptraPol and One Gloss produced equally rougher surfaces. Tetric EvoCeram exhibited the roughest surface with OptraPol, while no significant differences were found between Premise and CeramX. According to SEM images, OptraPol and One Gloss scratched and plucked the particles away from the surface, while PoGo created a uniform finish, although the roughness values were not the same for each composite. Effectiveness of the polishers seems to be material dependent.
Organization and Development of Bone Marrow Donation and Transplantation in Poland.
Filipiak, Jagoda; Dudkiewicz, Małgorzata; Czerwiński, Jarosław; Kosmala, Karolina; Łęczycka, Anna; Malanowski, Piotr; Żalikowska-Hołoweńko, Jolanta; Małkowski, Piotr; Danielewicz, Roman
2015-10-01
This paper describes bone marrow donation and transplantation in Poland in terms of its history, current state, and information on the quality control system. Based on data gathered from the informatics systems of the Polish Central Unrelated Potential Bone Marrow Donor and Cord Blood Registry and the Polish transplant registries, as well as World Marrow Donor Association statistics, we performed an overview study to collect and compare numbers on hematopoietic stem cells donations and transplantations in Poland in the years 2010-2014. In the last 5 years, the number of registered potential hematopoietic stem cells donors in Poland increased by more than 4 times, from about 146,000 to over 750,000. During the same period, the number of patients qualified to hematopoietic stem cells transplantation from unrelated donor increased from 557 in 2010 to 817 in 2014. We observed a striking change in the percentage of transplantations performed in Polish centers using material collected from national donors--from 24% to 60%. This shift was also evident in the number of search procedures closed with acceptation of Polish donors--from 27% in 2010 to 58% in 2014. Another consequence of Polish registry growth is the increasing number of donations from Polish donors for international patients. Between 2010 and 2014, the percent of donation for non-national patient increased from 33% to 76%, placing Poland in 6th place in the ranking of the HSC "exporters" worldwide. Growth of transplantation rates involves standardization process, which is a natural way of development for national organizations in the field of HSCT because of its international character.
Prediction of a nail polish colour applied on a nail.
Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M
2018-02-01
The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Adrenal incidentaloma in adults - management recommendations by the Polish Society of Endocrinology.
Bednarczuk, Tomasz; Bolanowski, Marek; Sworczak, Krzysztof; Górnicka, Barbara; Cieszanowski, Andrzej; Otto, Maciej; Ambroziak, Urszula; Pachucki, Janusz; Kubicka, Eliza; Babińska, Anna; Koperski, Łukasz; Januszewicz, Andrzej; Prejbisz, Aleksander; Górska, Maria; Jarząb, Barbara; Hubalewska-Dydejczyk, Alicja; Glinicki, Piotr; Ruchała, Marek; Kasperlik-Załuska, Anna
2016-01-01
A wide use of imaging techniques results in more frequent diagnosis of adrenal incidenataloma. To analyse the current state of knowledge on adrenal incidentaloma in adults in order to prepare practical management recommendations. Following a discussion, the Polish Society of Endocrinology expert working group have analysed the available data and summarised the analysis results in the form of recommendations. Unenhanced adrenal computed tomography (CT) may be recommended as an initial assessment examination helpful in the differentiation between adenomas and "non-adenomatous" lesions. In the case of density > 10 Hounsfield units, CT with contrast medium washout assessment or MRI are recommended. However, in all patients with adrenal incidentaloma, hormonal assessment is recommended in order to exclude pheochromocytoma and hypercortisolism, notwithstanding the clinical picture or concomitant diseases. In addition, examination to exclude primary hyperaldosteronism is suggested in patients with diagnosed hypertension or hypokalaemia. Surgical treatment should be recommended in patients with adrenal incidentaloma, where imaging examinations suggest a malignant lesion (oncological indication) or with confirmed hormonal activity (endocrinological indication). The basis of the surgical treatment is laparoscopic adrenalectomy. Patients with suspected pheochromocytoma must be pharmacologically prepared prior to surgery. In patients not qualified for surgery, control examinations (imaging and laboratory tests) should be established individually, taking into consideration such features as the size, image, and growth dynamics of the tumour, clinical symptoms, hormonal tests results, and concomitant diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frolov, Vladimir; Backhaus, Scott N.; Chertkov, Michael
2014-01-14
In a companion manuscript, we developed a novel optimization method for placement, sizing, and operation of Flexible Alternating Current Transmission System (FACTS) devices to relieve transmission network congestion. Specifically, we addressed FACTS that provide Series Compensation (SC) via modification of line inductance. In this manuscript, this heuristic algorithm and its solutions are explored on a number of test cases: a 30-bus test network and a realistically-sized model of the Polish grid (~2700 nodes and ~3300 lines). The results on the 30-bus network are used to study the general properties of the solutions including non-locality and sparsity. The Polish grid ismore » used as a demonstration of the computational efficiency of the heuristics that leverages sequential linearization of power flow constraints and cutting plane methods that take advantage of the sparse nature of the SC placement solutions. Using these approaches, the algorithm is able to solve an instance of Polish grid in tens of seconds. We explore the utility of the algorithm by analyzing transmission networks congested by (a) uniform load growth, (b) multiple overloaded configurations, and (c) sequential generator retirements« less
Holliday, S L; Scouten, A J; Beuchat, L R
2001-10-01
Alfalfa seeds are sometimes subjected to a scarification treatment to enhance water uptake, which results in more rapid and uniform germination during sprout production. It has been hypothesized that this mechanical abrasion treatment diminishes the efficacy of chemical treatments used to kill or remove pathogenic bacteria from seeds. A study was done to compare the effectiveness of chlorine (20,000 ppm), H2O, (8%), Ca(OH)2 (1%), Ca(OH)2 (1%) plus Tween 80 (1%), and Ca(OH)2 (1%) plus Span 20 (1%) treatments in killing Salmonella and Escherichia coli O157:H7 inoculated onto control, scarified, and polished alfalfa seeds obtained from two suppliers. The influence of the presence of organic material in the inoculum carrier on the efficacy of sanitizers was investigated. Overall, treatment with 1% Ca(OH)2 was the most effective in reducing populations of the pathogens. Reduction in populations of pathogens on seeds obtained from supplier I indicate that chemical treatments are less efficacious in eliminating the pathogens on scarified seeds compared to control seeds. However, the effectiveness of chemical treatment in removing Salmonella and E. coli O157:H7 from seeds obtained from supplier 2 was not markedly affected by scarification or polishing. The presence of organic material in the inoculum carrier did not have a marked influence on the efficacy of chemicals in reducing populations of test pathogens. Additional lots of control, scarified, and polished alfalfa seeds of additional varieties need to be tested before conclusions can be drawn concerning the impact of mechanical abrasion on the efficacy of chemical treatment in removing or killing Salmonella and E. coli O157:H7.
Effect of grinding and polishing on roughness and strength of zirconia.
Khayat, Waad; Chebib, Najla; Finkelman, Matthew; Khayat, Samer; Ali, Ala
2018-04-01
The clinical applications of high-translucency monolithic zirconia restorations have increased. Chairside and laboratory adjustments of these restorations are inevitable, which may lead to increased roughness and reduced strength. The influence of grinding and polishing on high-translucency zirconia has not been investigated. The purpose of this in vitro study was to compare the roughness averages (Ra) of ground and polished zirconia and investigate whether roughness influenced strength after aging. High-translucency zirconia disks were milled, sintered, and glazed according to the manufacturer's recommendations. Specimens were randomized to 4 equal groups. Group G received only grinding; groups GPB and GPK received grinding and polishing with different polishing systems; and group C was the (unground) control group. All specimens were subjected to hydrothermal aging in an autoclave at 134°C at 200 kPa for 3 hours. Roughness average was measured using a 3-dimensional (3D) optical interferometer at baseline (Ra1), after grinding and polishing (Ra2), and after aging (Ra3). A biaxial flexural strength test was performed at a rate of 0.5 mm/min. Statistical analyses were performed using commercial software (α=.05). Group G showed a significantly higher mean value of Ra3 (1.96 ±0.32 μm) than polished and glazed groups (P<.001), which showed no statistically significant difference among them (GPB, 1.12 ±0.31 µm; GPK, 0.88 ±0.31 µm; C: 0.87 ±0.25 μm) (P>.05). Compared with baseline, the roughness of groups G and GPB increased significantly after surface treatments and after aging, whereas aging did not significantly influence the roughness of groups GPK or C. Group G showed the lowest mean value of biaxial flexural strength (879.01 ±157.99 MPa), and the highest value was achieved by group C (962.40 ±113.84 MPa); no statistically significant differences were found among groups (P>.05). Additionally, no significant correlation was detected between the Ra and flexural strength of zirconia. Grinding increased the roughness of zirconia restorations, whereas proper polishing resulted in smoothness comparable with glazed surfaces. The results provide no evidence that grinding and polishing affect the flexural strength of zirconia after aging. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Automated Boiler Combustion Controls for Emission Reduction and Efficiency Improvement
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1998-12-02
In the late 1980s, then President Bush visited Krakow, Poland. The terrible air quality theremotivated him to initiate a USAID-funded program, managed by DOE, entitled "Krakow Clean Fossil Fuels and Energy Efficiency Program." The primary objective of this program was to encourage the formation of commercial ventures between U.S. and Polish firms to provide equipment and/or services to reduce pollution from low-emission sources in Krakow, Poland. This program led to the award of a number of cooperative agreements, including one to Control Techtronics International. The technical objective of CTI's cooperative agreement is to apply combustion controls to existing boiler plantsmore » in Krakow and transfer knowledge and technology through a joint U.S. and Polish commercial venture. CTI installed automatic combustion controls on five coal boilers for the district heating system in Krakow. Three of these were for domestic hot-water boilers, and two were for steam for industrial boilers. The following results have occurred due to the addition of CTI's combustion controls on these five existing boilers: ! 25% energy savings ! 85% reduction in particulate emissions The joint venture company CTI-Polska was then established. Eleven additional technical and costing proposals were initiated to upgrade other coal boilers in Krakow. To date, no co-financing has been made available on the Polish side. CTI-Polska continues in operation, serving customers in Russia and Ukraine. Should the market in Poland materialize, the joint venture company is established there to provide equipment and service.« less
Attack polish for nickel-base alloys and stainless steels
Steeves, Arthur F.; Buono, Donald P.
1983-01-01
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Method of polishing nickel-base alloys and stainless steels
Steeves, Arthur F.; Buono, Donald P.
1981-01-01
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Effect of Air-Polishing on Titanium Surfaces, Biofilm Removal, and Biocompatibility: A Pilot Study
Bennani, Vincent; Hwang, Linda; Tawse-Smith, Andrew; Dias, George J.; Cannon, Richard D.
2015-01-01
Purpose. The aims of this in vitro study were to evaluate morphological changes induced by glycine powder air-polishing on titanium surfaces, biofilm removal, and biocompatibility. Material and Methods. Titanium grade IV discs were allocated into two groups: (1) discs without biofilm and (2) discs for Streptococcus mutans biofilm formation. Discs in each group were further subdivided into (a) no treatment and (b) air-polishing treatment with glycine powder. Discs were characterized by scanning electron microscopy (SEM), electron-dispersive spectroscopy (EDS), and confocal microscopy. Bacterial biofilms were quantified using a crystal violet dye-binding assay. Biocompatibility was evaluated by measuring the coverage and viability of L929 fibroblast cells cultured on the discs. Results. Air-polishing increased the roughness of treated discs (P < 0.05). EDS analysis did not show significant differences in the chemical composition of treated and nontreated discs. The amount of residual biofilm on treated discs was 8.6-fold lower than untreated controls (P < 0.05). Coverage of treated discs by fibroblasts was half that of untreated discs (P < 0.05) although both groups had the same cell viability. Conclusions. Air-polishing removed a significant amount of biofilm from titanium surfaces. The “polishing” was accompanied by increased surface roughness, but there were no changes in chemical and elemental compositions, nor the biocompatibility. PMID:26881198
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanford, G.A.
1980-02-12
An oil well pump drive is disclosed including a drive unit that is hydraulically actuated by a double-acting hydraulic cylinder to reciprocate vertically. An endless chain is entrained over vertically spaced sprockets carried by the unit, with one flight of the chain anchored against vertical movement and the other flight is secured to the pump polish rod so that the vertical motion imparted to the polish rod is double that hydraulically imparted to the drive unit. The polish rod load on the chain is opposed by a counterweight connected thereto by a chain extending over an elevated pulley. The outputmore » of the hydraulic pump supplying the hydraulic cylinder is cam controlled so that the motion of the drive unit is smoothly decelerated and accelerated as the unit approaches and moves from the upper and lower limits of its movement.« less
Li, Ya; Pang, Hai-Dong; He, Lin-Yan; Wang, Qi; Sheng, Xia-Fang
2017-04-01
Two metal-resistant Bacillus megaterium H3 and Neorhizobium huautlense T1-17 were investigated for their immobilization of Cd in solution and tissue Cd accumulation of rice (Oryza sativa wuyun-23) in the Cd-contaminated soil. Strains H3 and T1-17 decreased 79-96% of water-soluble Cd in solution and increased grain biomass in the high Cd-contaminated soil. Inoculation with H3 and T1-17 significantly decreased the root (ranging from 25% to 58%), above-ground tissue (ranging from 13% to 34%), and polished rice (ranging from 45% to 72%) Cd contents as well as Cd bioconcentration factor of the rice compared to the controls. Furthermore, H3 and T1-17 significantly reduced the exchangeable Cd content of the rhizosphere soils compared with the controls. Notably, strain T1-17 had significantly higher ability to reduce Cd bioconcentration factor and polished rice Cd uptake than strain H3. The results demonstrated that H3 and T1-17 decreased the tissue (especially polished rice) Cd uptake by decreasing Cd availability in soil and Cd bioconcentration factor and the effect on the reduced polished rice Cd uptake was dependent on the strains. The results may provide an effective synergistic bioremediation of Cd-contaminated soils in the bacteria and rice plants and bacterial-assisted safe production of rice in Cd-contaminated soils. Copyright © 2016 Elsevier Inc. All rights reserved.
Xie, Pusheng; Ouyang, Hanbin; Deng, Yuping; Yang, Yang; Xu, Jing; Huang, Wenhua
2017-09-02
Additive manufacturing (AM) technology has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. But the application of direct metal laser sintering (DMLS) bone plate is quite limited due to the indeterminate mechanical property. The purposes of this study were to characterize the biomechanical properties of the polished DMLS reconstruction plate and to compare these with the properties of commonly applied implants and to find whether the mechanical performance of DMLS plate meets the requirements for clinical application. In this study, we fabricated two groups of plates by DMLS and computer numerical control (CNC) techniques. After that, we polished all samples and investigated their roughness, components, hardness, static bending, and torsional performance. Moreover, cyclic bending tests and fractographic analysis were conducted. Statistical comparisons of the group by means of monotonic test data were made, and a qualitative comparison was performed to assess failures in fatigue. We found no differences in surface roughness or components after polishing, but the DMLS plate hardness is 7.42% (p < 0.01) greater than that of the CNC plates. Compared with the CNC plates, the DMLS plate static bending and torsional performance were significantly greater. In a dynamic test, the DMLS plates survived 10 6 , 10 6 , 32,731, and 33,264 cycles under 0.6, 0.8, 0.9, and 1 kN cyclic loads, respectively, while the CNC plates survived 10 6 , 10 6 , 10 6 , and 283,714 cycles. These results indicate that the mechanical performances of the DMLS plate are stronger, and the strength under fatigue tests is sufficient. DMLS implant has great potential and may become a better choice for clinical use in the future. However, direct application of these AM instruments in the operating room requires further validation including animal and clinical experiment.
Discoloration of various CAD/CAM blocks after immersion in coffee.
Lauvahutanon, Sasipin; Shiozawa, Maho; Takahashi, Hidekazu; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J; Arksornnukit, Mansuang
2017-02-01
This study evaluated color differences (Δ E s) and translucency parameter changes (Δ TP s) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L * a * b * values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds ( n = 6). The Δ E s and Δ TP s of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The Δ E s after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. After one month in coffee, Δ E s of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and Δ TP s decreased. The ANOVA of Δ E s and Δ TP s revealed significant differences in two main factors, immersion periods and media, and their interaction except for Δ E s of TEL (Telio CAD, Ivoclar Vivadent). The Δ E s significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between Δ E s and water sorption or solubility in water. The Δ E s of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, N.; Miyamaru, K.
1995-03-01
The new TEPCO BWR`s are capable of having the occupational radiation exposure controlled successfully at a low level by selecting low cobalt steel, using corrosion-resistant steel, employing dual condensate polishing systems, and controlling Ni/Fe ratio during operation. The occupational radiation exposure of the old BWR`s, on the other hand, remains high though reduced substantially through the use of low cobalt replacement steel and the partial addition of a filter in the condensate polishing system. Currently under review is the overall decontamination procedure for the old BWR`s to find out to measures needed to reduce the amount of crud that ismore » and has been carried over into the nuclear reactor. The current status of decontamination is reported below.« less
Kakaboura, A; Vougiouklakis, G; Argiri, G
1989-01-01
Finishing and polishing an amalgam restoration, is considered as an important and necessary step of the restorative procedure. Various polishing techniques have been recommended to success a smooth amalgam surface. The aim of this study was to investigate the influence of three different polishing treatments on the marginal integrity and surface smoothness of restorations made of three commercially available amalgams and a glass-cermet cement. The materials used were the amalgams, Amalcap (Vivadent), Dispersalloy (Johnson and Johnson), Duralloy (Degussa) and the glass-cermet Katac-Silver (ESPE). The occlusal surfaces of the restorations were polished by the methods: I) round bur, No4-rubber cup-zinc oxide paste in a small brush, II) round bur No 4-bur-brown, green and super green (Shofu) polishing cups and points successively and III) amalgam polishing bur of 12-blades-smooth amalgam polishing bur. Photographs from unpolished and polished surfaces of the restorations, were taken with scanning electron microscope, to evaluate the polishing techniques. An improvement of marginal integrity and surface smoothness of all amalgam restorations was observed after the specimens had been polished with the three techniques. Method II, included Shofu polishers, proved the best results in comparison to the methods I and III. Polishing of glass-cermet cement was impossible with the examined techniques.
Hyzy, Sharon L; Cheng, Alice; Cohen, David J; Yatzkaier, Gustavo; Whitehead, Alexander J; Clohessy, Ryan M; Gittens, Rolando A; Boyan, Barbara D; Schwartz, Zvi
2016-08-01
The purpose of this study was to compare the biological effects in vivo of hierarchical surface roughness on laser sintered titanium-aluminum-vanadium (Ti-6Al-4V) implants to those of conventionally machined implants on osteoblast response in vitro and osseointegration. Laser sintered disks were fabricated to have micro-/nano-roughness and wettability. Control disks were computer numerical control (CNC) milled and then polished to be smooth (CNC-M). Laser sintered disks were polished smooth (LST-M), grit blasted (LST-B), or blasted and acid etched (LST-BE). LST-BE implants or implants manufactured by CNC milling and grit blasted (CNC-B) were implanted in the femurs of male New Zealand white rabbits. Most osteoblast differentiation markers and local factors were enhanced on rough LST-B and LST-BE surfaces in comparison to smooth CNC-M or LST-M surfaces for MG63 and normal human osteoblast cells. To determine if LST-BE implants were osteogenic in vivo, we compared them to implant surfaces used clinically. LST-BE implants had a unique surface with combined micro-/nano-roughness and higher wettability than conventional CNC-B implants. Histomorphometric analysis demonstrated a significant improvement in cortical bone-implant contact of LST-BE implants compared to CNC-B implants after 3 and 6 weeks. However, mechanical testing revealed no differences between implant pullout forces at those time points. LST surfaces enhanced osteoblast differentiation and production of local factors in vitro and improved the osseointegration process in vivo. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2086-2098, 2016. © 2016 Wiley Periodicals, Inc.
Walker, David; Yu, Guoyu; Li, Hongyu; Messelink, Wilhelmus; Evans, Rob; Beaucamp, Anthony
2012-08-27
Segment-edges for extremely large telescopes are critical for observations requiring high contrast and SNR, e.g. detecting exo-planets. In parallel, industrial requirements for edge-control are emerging in several applications. This paper reports on a new approach, where edges are controlled throughout polishing of the entire surface of a part, which has been pre-machined to its final external dimensions. The method deploys compliant bonnets delivering influence functions of variable diameter, complemented by small pitch tools sized to accommodate aspheric mis-fit. We describe results on witness hexagons in preparation for full size prototype segments for the European Extremely Large Telescope, and comment on wider applications of the technology.
Rutkowski, Marcin; Zdrojewski, Tomasz; Bandosz, Piotr; Wierucki, Lukasz; Piwoński, Jerzy; Piwońska, Aleksandra; Narkiewicz, Krzysztof; Opolski, Grzegorz; Drygas, Wojciech; Korewicki, Jerzy; Wyrzykowski, Bogdan
2007-05-01
Cardiovascular diseases are the most common cause of mortality in Poland. To improve the situation in this area, a national cardiovascular preventive project is necessary, and it can be done by close cooperation between medical and political agencies. To present the current epidemiological situation in Poland to political and key opinion leaders and also to assess individual cardiovascular risk among Members of Polish Parliament. The Project was carried out on 23-24 May 2006 in the residence of the Polish Parliament. Anthropometric, blood pressure and cholesterol measurements and a short questionnaire were performed. Survey and educational programme were carried out on 310 out of 460 Members of the Polish Parliament (females 59, males 251). Awareness of one's own blood pressure was declared by 70% of subjects, 39% declared earlier detected arterial hypertension, 21% had new detected elevated blood pressure, 31% declared earlier detected elevated cholesterol level and 32% had new detected elevated cholesterol level. Obesity was found in 40%, smoking was declared by 16.5%. The results were compared with those obtained in corresponding age-groups in the general population. 1. The results of screening survey in the Polish Parliament in 2006 indicate that, in comparison with nationwide adult population and Parliament Members examined in the year of 2000, present Parliament Members are more often diagnosed with obesity. However, they present with a better awareness of their own blood pressure and better control of arterial hypertension, as well as much lower percentage of those who admit smoking cigarettes. 2. Drawing Parliament Members attention to the problem of high prevalence and insufficient control of cardiovascular risk factors should result in positive outcome of future legislation process and make the battle with the epidemic of heart attacks and strokes in Poland more successful.
Knowledge of chronic total occlusion among Polish interventional cardiologists.
Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek
2015-01-01
Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Questionnaire survey performed during two major Polish invasive cardiology workshops. In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient.
Effects of the gap slope on the distribution of removal rate in Belt-MRF.
Wang, Dekang; Hu, Haixiang; Li, Longxiang; Bai, Yang; Luo, Xiao; Xue, Donglin; Zhang, Xuejun
2017-10-30
Belt magnetorheological finishing (Belt-MRF) is a promising tool for large-optics processing. However, before using a spot, its shape should be designed and controlled by the polishing gap. Previous research revealed a remarkably nonlinear relationship between the removal function and normal pressure distribution. The pressure is nonlinearly related to the gap geometry, precluding prediction of the removal function given the polishing gap. Here, we used the concepts of gap slope and virtual ribbon to develop a model of removal profiles in Belt-MRF. Between the belt and the workpiece in the main polishing area, a gap which changes linearly along the flow direction was created using a flat-bottom magnet box. The pressure distribution and removal function were calculated. Simulations were consistent with experiments. Different removal functions, consistent with theoretical calculations, were obtained by adjusting the gap slope. This approach allows to predict removal functions in Belt-MRF.
NASA Astrophysics Data System (ADS)
Yang, Minghong; Qi, Hongji; Zhao, Yuanan; Yi, Kui
2012-01-01
The 355 nm laser-induced damage thresholds (LIDTs) of polished fused silica with and without the residual subsurface cracks were explored. HF based wet etching and magnetorheological finishing was used to remove the subsurface cracks. To isolate the effect of subsurface cracks, chemical leaching was used to eliminate the photoactive impurities in the polishing layer. Results show that the crack number density decreased from~103 to <1cm-2, and the LIDT was improved as high as 2.8-fold with both the subsurface cracks and the polishing layer being removed. Subsurface cracks play a significant role in laser damage at fluencies between 15~31 J/cm2 (355nm, 8ns). HF Etching of the cracks was shown to increase the damage performance as nearly high as that of the samples in which subsurface cracks are well controlled.
Influence of copper morphology in forming nucleation seeds for graphene growth.
Han, Gang Hee; Güneş, Fethullah; Bae, Jung Jun; Kim, Eun Sung; Chae, Seung Jin; Shin, Hyeon-Jin; Choi, Jae-Young; Pribat, Didier; Lee, Young Hee
2011-10-12
We report that highly crystalline graphene can be obtained from well-controlled surface morphology of the copper substrate. Flat copper surface was prepared by using a chemical mechanical polishing method. At early growth stage, the density of graphene nucleation seeds from polished Cu film was much lower and the domain sizes of graphene flakes were larger than those from unpolished Cu film. At later growth stage, these domains were stitched together to form monolayer graphene, where the orientation of each domain crystal was unexpectedly not much different from each other. We also found that grain boundaries and intentionally formed scratched area play an important role for nucleation seeds. Although the best monolayer graphene was grown from polished Cu with a low sheet resistance of 260 Ω/sq, a small portion of multilayers were also formed near the impurity particles or locally protruded parts.
Investigation of Al Coated Mg for Biomedical Applications
NASA Astrophysics Data System (ADS)
Elmrabet, Nabila; Roe, Martin; Neate, Nigel; Grant, David M.; Brown, Paul D.
The corrosion resistant properties of 1-2 μm thick Al coatings deposited by radio frequency magnetron sputtering on polished Mg surfaces, within Ar and Ar/H2 environments, have been appraised. The coatings were heat-treated at 300°C for 5 h to induce the formation of bioinert Al2O3, and samples were corroded within phosphate buffered saline solution at 37°C to mimic the biological environment. Both the as-deposited and heat-treated coatings were found to delay the onset of corrosion, but showed higher initial corrosion rates, once established, as compared with polished Mg surfaces. Slightly improved performance of the coatings was achieved through the addition of H2 to the system which acted to inhibit Al-Mg alloying and MgO formation. However, localized accelerated corrosion associated with substrate polishing damage emphasized the need for improved process control and coating uniformity.
Suratwala, Tayyab; Steele, Rusty; Feit, Michael; Dylla-Spears, Rebecca; Desjardin, Richard; Mason, Dan; Wong, Lana; Geraghty, Paul; Miller, Phil; Shen, Nan
2014-01-01
Convergent Polishing is a novel polishing system and method for finishing flat and spherical glass optics in which a workpiece, independent of its initial shape (i.e., surface figure), will converge to final surface figure with excellent surface quality under a fixed, unchanging set of polishing parameters in a single polishing iteration. In contrast, conventional full aperture polishing methods require multiple, often long, iterative cycles involving polishing, metrology and process changes to achieve the desired surface figure. The Convergent Polishing process is based on the concept of workpiece-lap height mismatch resulting in pressure differential that decreases with removal and results in the workpiece converging to the shape of the lap. The successful implementation of the Convergent Polishing process is a result of the combination of a number of technologies to remove all sources of non-uniform spatial material removal (except for workpiece-lap mismatch) for surface figure convergence and to reduce the number of rogue particles in the system for low scratch densities and low roughness. The Convergent Polishing process has been demonstrated for the fabrication of both flats and spheres of various shapes, sizes, and aspect ratios on various glass materials. The practical impact is that high quality optical components can be fabricated more rapidly, more repeatedly, with less metrology, and with less labor, resulting in lower unit costs. In this study, the Convergent Polishing protocol is specifically described for fabricating 26.5 cm square fused silica flats from a fine ground surface to a polished ~λ/2 surface figure after polishing 4 hr per surface on a 81 cm diameter polisher. PMID:25489745
Visible light scatter measurements of the Advanced X-ray Astronomical Facility /AXAF/ mirror samples
NASA Technical Reports Server (NTRS)
Griner, D. B.
1981-01-01
NASA is studying the properties of mirror surfaces for X-ray telescopes, the data of which will be used to develop the telescope system for the Advanced X-ray Astronomical Facility. Visible light scatter measurements, using a computer controlled scanner, are made of various mirror samples to determine surface roughness. Total diffuse scatter is calculated using numerical integration techniques and used to estimate the rms surface roughness. The data measurements are then compared with X-ray scatter measurements of the same samples. A summary of the data generated is presented, along with graphs showing changes in scatter on samples before and after cleaning. Results show that very smooth surfaces can be polished on the common substrate materials (from 2 to 10 Angstroms), and nickel appears to give the lowest visible light scatter.
Biocompatibility and hemocompatibility of surface-modified NiTi alloys.
Armitage, David A; Parker, Terry L; Grant, David M
2003-07-01
Nickel titanium (NiTi) shape memory alloys have been investigated for several years with regard to biomedical applications. However, little is known about the influences of surface modifications on the biocompatibility of these alloys. The effects of a range of surface treatments were investigated. Cytotoxicity and cytocompatibility studies with both fibroblast and endothelial cells showed no differences in the biocompatibility of any of the NiTi surfaces. The cytotoxicity and cytocompatibility of all surfaces were favorable compared to the controls. The hemolysis caused by a range of NiTi surfaces was no different from that caused by polished 316L stainless steel or polished titanium surfaces. The spreading of platelets has been linked to the thrombogenicity of materials. Platelet studies here showed a significant increase in thrombogenicity on polished NiTi surfaces compared to 316L stainless steel and pure titanium surfaces. Heat treatment of NiTi was found to significantly reduce thrombogenicity, to the level of the control. The XPS results showed a significant decrease in the concentration of surface nickel with heat treatment and changes in the surface nickel itself from a metallic to an oxide state. This correlates with the observed reduction in thrombogenicity. Copyright 2003 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Menezes, Pradeep L.; Kishore; Kailas, Satish V.; Lovell, Michael R.
2015-01-01
Surface texture influences friction during sliding contact conditions. In the present investigation, the effect of surface texture and roughness of softer and harder counter materials on friction during sliding was analyzed using an inclined scratch testing system. In the experiments, two test configurations, namely (a) steel balls against aluminum alloy flats of different surface textures and (b) aluminum alloy pins against steel flats of different surface textures, are utilized. The surface textures were classified into unidirectionally ground, 8-ground, and randomly polished. For a given texture, the roughness of the flat surfaces was varied using grinding or polishing methods. Optical profilometer and scanning electron microscope were used to characterize the contact surfaces before and after the experiments. Experimental results showed that the surface textures of both harder and softer materials are important in controlling the frictional behavior. The softer material surface textures showed larger variations in friction between ground and polished surfaces. However, the harder material surface textures demonstrated a better control over friction among the ground surfaces. Although the effect of roughness on friction was less significant when compared to textures, the harder material roughness showed better correlations when compared to the softer material roughness.
Attack polish for nickel-base alloys and stainless steels
Not Available
1980-05-28
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels is described. The chemical attack polich comprises FeNO/sub 3/, concentrated CH/sub 3/COOH, concentrated H/sub 2/SO/sub 4/ and H/sub 2/O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Uchmanowicz, Izabella; Wleklik, Marta
According to the guidelines of the European Society of Cardiology, education in heart failure (HF) should focus on preparing the patient for self-control and self-care. Only systematic assessment of the level of self-care in HF enables the optimisation and adaptation of education to meet the patient's needs. The research tool commonly used to assess self-care in HF patients is the nine-item European Heart Failure Self-care Behaviour Scale (9-EHFScBS). To test the reliability of the Polish version of the 9-EHFScBS. A standard guideline was used for the translation and cultural adaptation of the English version of the 9-EHFScBS into Polish. The study included 110 Polish patients (mean age 66.0 ± 11.4 years); 51 men and 59 women. Cronbach's alpha was used for the analysis of the internal consistency of the 9-EHFScBS. The mean overall level of self-care in the study group was 27.65 points (SD 7.13 points). Good or satisfactory levels of self-care were found in three out of nine analysed variables. The reliability of the self-care scale was alpha = 0.787. The value of Cronbach's alpha after the exclusion of individual statements ranged from 0.75 to 0.81. The 9-EHFScBS questionnaire is a reliable research tool in assessing the level of self-care among patients with HF in the Polish population.
Optimization of a mainstream nitritation-denitritation process and anammox polishing.
Regmi, Pusker; Holgate, Becky; Fredericks, Dana; Miller, Mark W; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B
2015-01-01
This paper deals with an almost 1-year long pilot study of a nitritation-denitritation process that was followed by anammox polishing. The pilot plant treated real municipal wastewater at ambient temperatures. The effluent of high-rate activated sludge process (hydraulic retention time, HRT=30 min, solids retention time=0.25 d) was fed to the pilot plant described in this paper, where a constant temperature of 23 °C was maintained. The nitritation-denitritation process was operated to promote nitrite oxidizing bacteria out-selection in an intermittently aerated reactor. The intermittent aeration pattern was controlled using a strategy based on effluent ammonia and nitrate+nitrite concentrations. The unique feature of this aeration control was that fixed dissolved oxygen set-point was used and the length of aerobic and anoxic durations were changed based on the effluent ammonia and nitrate+nitrite concentrations. The anaerobic ammonia oxidation (anammox) bacteria were adapted in mainstream conditions by allowing the growth on the moving bed bioreactor plastic media in a fully anoxic reactor. The total inorganic nitrogen (TIN) removal performance of the entire system was 75±15% during the study at a modest influent chemical oxygen demand (COD)/NH4+-N ratio of 8.9±1.8 within the HRT range of 3.1-9.4 h. Anammox polishing contributed 11% of overall TIN removal. Therefore, this pilot-scale study demonstrates that application of the proposed nitritation-denitritation system followed by anammox polishing is capable of relatively high nitrogen removal without supplemental carbon and alkalinity at a low HRT.
Neutral ion sources in precision manufacturing
NASA Technical Reports Server (NTRS)
Fawcett, Steven C.; Drueding, Thomas W.
1994-01-01
Ion figuring of optical components is a relatively new technology that can alleviate some of the problems associated with traditional contact polishing. Because the technique is non contacting, edge distortions and rib structure print through do not occur. This initial investigation was aimed at determining the effect of ion figuring on surface roughness of previously polished or ductile ground ceramic optical samples. This is the first step in research directed toward the combination of a pre-finishing process (ductile grinding or polishing) with ion figuring to produce finished ceramic mirrors. The second phase of the project is focusing on the development of mathematical algorithms that will deconvolve the ion beam profile from the surface figure errors so that these errors can be successfully removed from the optical components. In the initial phase of the project, multiple, chemical vapor deposited silicon carbide (CVD SiC) samples were polished or ductile ground to specular or near-specular roughness. These samples were then characterized to determine topographic surface information. The surface evaluation consisted of stylus profilometry, interferometry, and optical and scanning electron microscopy. The surfaces, were ion machined to depths from 0-5 microns. The finished surfaces were characterized to evaluate the effects of the ion machining process with respect to the previous processing methods and the pre-existing subsurface damage. The development of the control algorithms for figuring optical components has been completed. These algorithms have been validated with simulations and future experiments have been planned to verify the methods. This paper will present the results of the initial surface finish experiments and the control algorithms simulations.
Simultaneous ion sputter polishing and deposition
NASA Technical Reports Server (NTRS)
Rutledge, S.; Banks, B.; Brdar, M.
1981-01-01
Results of experiments to study ion beam sputter polishing in conjunction with simultaneous deposition as a mean of polishing copper surfaces are presented. Two types of simultaneous ion sputter polishing and deposition were used in these experiments. The first type utilized sputter polishing simultaneous with vapor deposition, and the second type utilized sputter polishing simultaneous with sputter deposition. The etch and deposition rates of both techniques were studied, as well as the surface morphology and surface roughness.
Super-polishing of Zerodur aspheres by means of conventional polishing technology
NASA Astrophysics Data System (ADS)
Polak, Jaroslav; Klepetková, Eva; Pošmourný, Josef; Šulc, Miroslav; Procháska, František; Tomka, David; Matoušek, Ondřej; Poláková, Ivana; Šubert, Eduard
2015-01-01
This paper describes a quest to find simple technique to superpolish Zerodur asphere (55μm departure from best fit sphere) that could be employed on old fashion way 1-excenter optical polishing machine. The work focuses on selection of polishing technology, study of different polishing slurries and optimization of polishing setup. It is demonstrated that either by use of fine colloidal CeO2 slurry or by use of bowl-feed polishing setup with CeO2 charged pitch we could reach 0.4nm RMS roughness while removing <30nm of surface layer. This technique, although not optimized, was successfully used to improve surface roughness on already prepolished Zerodur aspheres without necessity to involve sophisticated super-polishing technology and highly trained manpower.
Diagnostics and Treatment of Thyroid Carcinoma.
Jarząb, Barbara; Dedecjus, Marek; Handkiewicz-Junak, Daria; Lange, Dariusz; Lewiński, Andrzej; Nasierowska-Guttmejer, Anna; Ruchała, Marek; Słowińska-Klencka, Dorota; Nauman, Janusz; Adamczewski, Zbigniew; Bagłaj, Maciej; Bałdys-Waligórska, Agata; Barczyński, Marcin; Bednarczuk, Tomasz; Cichocki, Andrzej; Czarniecka, Agnieszka; Czepczyński, Rafał; Gawlik, Aneta; Hubalewska-Dydejczyk, Alicja; Jażdżewski, Krystian; Kamiński, Grzegorz; Karbownik-Lewińska, Małgorzata; Kos-Kudła, Beata; Kułakowski, Andrzej; Kuzdak, Krzysztof; Łącka, Katarzyna; Małecka-Tendera, Ewa; Niedziela, Marek; Pomorski, Lech; Sporny, Stanisław; Stojcev, Zoran; Syrenicz, Anhelli; Włoch, Jan; Krajewska, Jolanta; Szpak-Ulczok, Sylwia; Kalemba, Michal; Buziak-Bereza, Monika
2016-01-01
Revised Guidelines of Polish National Societies Prepared on the initiative of the Polish Group for Endocrine Tumours approved in their final version between November 16th and 28th, 2015 by the Scientific Committee of the V Conference "Thyroid Cancer and other malignancies of endocrine glands" organised between November 14th and 17th, 2015 in Wisla, Poland; called by the following Societies: Polish Endocrine Society, Polish Society of Oncology, Polish Thyroid Association, Polish Society of Pathologists, Society of Polish Surgeons, Polish Society of Surgical Oncology, Polish Society of Clinical Oncology, Polish Society of Radiation Oncology, Polish Society of Nuclear Medicine, Polish Society of Paediatric Endocrinology, Polish Society of Paediatric Surgeons, Polish Society of Ultrasonography Gliwice-Wisła, 2015 DECLARATION: These recommendations are created by the group of delegates of the National Societies, which declare their willingness to participate in the preparation of the revised version of the Polish Guidelines. The members of the Working Group have been chosen from the specialists involved in medical care of patients with thyroid carcinoma. Directly before the preparation of the Polish national recommendations the American Thyroid Association (ATA) published its own guidelines together with a wide comment fulfilling evidence-based medicine (EBM) criteria. ATA Guidelines are consistent with National Comprehensive Cancer Network (NCCN) Recommendation. According to the members of the Working Group, it is necessary to adapt them to both the specific Polish epidemiological situation as well as to the rules referring to the Polish health system. Therefore, the Polish recommendations constitute a consensus of the experts' group, based on ATA information. The experts analysed previous Polish Guidelines, published in 2010, and other available data, and after discussion summed up the results in the form of these guidelines. It should be added that Part II, which constitutes a pathological part, has been available at the website of the Polish Society of Pathologists for acceptance of the members of the Society, and no essential comments have been proposed. The Members of the Group decided that a subgroup elected from among them would update the Guidelines, according to EBM rules, every year. The Revised Guidelines should help physicians to make reasonable choices in their daily practice; however, the final decision concerning an individual patient should be made by the caring physician responsible for treatment, or optimally by a therapeutic tumour board together with the patient, and should take into consideration the patient's health condition. It should be emphasised that the recommendations may not constitute a strict standard of clinical management imposed on medical staff. The data from clinical trials concerning numerous clinical situations are scarce. In such moments the opinion of the management may differ from the recommendations after considering possible benefits and disadvantages for the patient.
Centre for Research Infrastructure of Polish GNSS Data - response and possible contribution to EPOS
NASA Astrophysics Data System (ADS)
Araszkiewicz, Andrzej; Rohm, Witold; Bosy, Jaroslaw; Szolucha, Marcin; Kaplon, Jan; Kroszczynski, Krzysztof
2017-04-01
In the frame of the first call under Action 4.2: Development of modern research infrastructure of the science sector in the Smart Growth Operational Programme 2014-2020 in the late of 2016 the "EPOS-PL" project has launched. Following institutes are responsible for the implementation of this project: Institute of Geophysics, Polish Academy of Sciences - Project Leader, Academic Computer Centre Cyfronet AGH University of Science and Technology, Central Mining Institute, the Institute of Geodesy and Cartography, Wrocław University of Environmental and Life Sciences, Military University of Technology. In addition, resources constituting entrepreneur's own contribution will come from the Polish Mining Group. Research Infrastructure EPOS-PL will integrate both existing and newly built National Research Infrastructures (Theme Centre for Research Infrastructures), which, under the premise of the program EPOS, are financed exclusively by the national founds. In addition, the e-science platform will be developed. The Centre for Research Infrastructure of GNSS Data (CIBDG - Task 5) will be built based on the experience and facilities of two institutions: Military University of Technology and Wrocław University of Environmental and Life Sciences. The project includes the construction of the National GNNS Repository with data QC procedures and adaptation of two Regional GNNS Analysis Centres for rapid and long-term geodynamical monitoring.
Total Internal Reflection Microscopy (TIRM) as a nondestructive surface damage assessment tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liao, Z.M.; Cohen, S.J.; Taylor, J.R.
1994-10-01
An easy to use, nondestructive, method for evaluating subsurface damage in polished substrates has been established at LLNL. Subsurface damage has been related to laser damage in coated optical components used in high power, high repetition rate laser systems. Total Internal Reflection Microscopy (TIRM) has been shown to be a viable nondestructive technique in analyzing subsurface damage in optical components. A successful TIRM system has been established for evaluating subsurface damage on fused silica components. Laser light scattering from subsurface damage sites is collected through a Nomarski microscope. These images are then captured by a CCD camera for analysis onmore » a computer. A variety of optics, including components with intentional subsurface damage due to grinding and polishing, have been analyzed and their TIRM images compared to an existing destructive etching method. Methods for quantitative measurement of subsurface damage are also discussed.« less
Manufacture of a combined primary and tertiary mirror for the Large Synoptic Survey Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Burge, J. H.; Cuerden, B.; Davison, W. B.; Kingsley, J. S.; Lutz, R. D.; Miller, S. M.; Tuell, M.
2008-07-01
The Large Synoptic Survey Telescope uses a unique optomechanical design that places the primary and tertiary mirrors on a single glass substrate. The honeycomb sandwich mirror blank was formed in March 2008 by spin-casting. The surface is currently a paraboloid with a 9.9 m focal length matching the primary. The deeper curve of the tertiary mirror will be produced when the surfaces are generated. Both mirrors will be lapped and polished using stressed laps and other tools on an 8.4 m polishing machine. The highly aspheric primary mirror will be measured through a refractive null lens, and a computer-generated hologram will be used to validate the null lens. The tertiary mirror will be measured through a diffractive null corrector, also validated with a separate hologram. The holograms for the two tests provide alignment references that will be used to make the axes of the two surfaces coincide.
[Surface characteristics of the acrylic resins according to the polishing methods].
Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia
2011-01-01
The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.
Kim, Dong-Woo; Cho, Myeong-Woo; Seo, Tae-Il; Shin, Young-Jae
2008-01-01
Recently, the magnetorheological (MR) polishing process has been examined as a new ultra-precision polishing technology for micro parts in MEMS applications. In the MR polishing process, the magnetic force plays a dominant role. This method uses MR fluids which contains micro abrasives as a polishing media. The objective of the present research is to shed light onto the material removal mechanism under various slurry conditions for polishing and to investigate surface characteristics, including shape analysis and surface roughness measurement, of spots obtained from the MR polishing process using alumina abrasives. A series of basic experiments were first performed to determine the optimum polishing conditions for BK7 glass using prepared slurries by changing the process parameters, such as wheel rotating speed and electric current. Using the obtained results, groove polishing was then performed and the results are investigated. Outstanding surface roughness of Ra=3.8nm was obtained on the BK7 glass specimen. The present results highlight the possibility of applying this polishing method to ultra-precision micro parts production, especially in MEMS applications. PMID:27879705
Pabel, Anne-Kathrin; Rödiger, Matthias
2016-01-01
The chairside fabrication of a monolithic partial crown using a zirconia-reinforced lithium silicate (ZLS) ceramic is described. The fully digitized model-free workflow in a dental practice is possible due to the use of a powder-free intraoral scanner and the computer-aided design/computer-assisted manufacturing (CAD/CAM) of the restorations. The innovative ZLS material offers a singular combination of fracture strength (>370 Mpa), optimum polishing characteristics, and excellent optical properties. Therefore, this ceramic is an interesting alternative material for monolithic restorations produced in a digital workflow. PMID:27042362
Subaperture metrology technologies extend capabilities in optics manufacturing
NASA Astrophysics Data System (ADS)
Tricard, Marc; Forbes, Greg; Murphy, Paul
2005-10-01
Subaperture polishing technologies have radically changed the landscape of precision optics manufacturing and enabled the production of higher precision optics with increasingly difficult figure requirements. However, metrology is a critical piece of the optics fabrication process, and the dependence on interferometry is especially acute for computer-controlled, deterministic finishing. Without accurate full-aperture metrology, figure correction using subaperture polishing technologies would not be possible. QED Technologies has developed the Subaperture Stitching Interferometer (SSI) that extends the effective aperture and dynamic range of a phase measuring interferometer. The SSI's novel developments in software and hardware improve the capacity and accuracy of traditional interferometers, overcoming many of the limitations previously faced. The SSI performs high-accuracy automated measurements of spheres, flats, and mild aspheres up to 200 mm in diameter by stitching subaperture data. The system combines a six-axis precision workstation, a commercial Fizeau interferometer of 4" or 6" aperture, and dedicated software. QED's software automates the measurement design, data acquisition, and mathematical reconstruction of the full-aperture phase map. The stitching algorithm incorporates a general framework for compensating several types of errors introduced by the interferometer and stage mechanics. These include positioning errors, viewing system distortion, the system reference wave error, etc. The SSI has been proven to deliver the accurate and flexible metrology that is vital to precision optics fabrication. This paper will briefly review the capabilities of the SSI as a production-ready, metrology system that enables costeffective manufacturing of precision optical surfaces.
Nowicki, Roman; Trzeciak, Magdalena; Wilkowska, Aleksandra; Sokołowska-Wojdyło, Małgorzata; Ługowska-Umer, Hanna; Barańska-Rybak, Wioletta; Kaczmarski, Maciej; Kowalewski, Cezary; Kruszewski, Jerzy; Maj, Joanna; Silny, Wojciech; Śpiewak, Radosław; Petranyuk, Andriy
2015-08-01
Atopic dermatitis (AD) is a condition frequently encountered in medical practices across the country. More than 60% of children with AD are at risk to develop allergic rhinitis or asthma (the atopic march). Patients with AD have a unique predisposition to colonization or infection by Staphylococcus aureus. Treatments for AD need to rapidly control symptoms of the disease, improve quality of life and prevent exacerbations. Given the chronic and relapsing nature of the disease, therapies need to encourage good compliance and be well tolerated.
Health Information in Polish (polski)
... Tools You Are Here: Home → Multiple Languages → Polish (polski) URL of this page: https://medlineplus.gov/languages/polish.html Health Information in Polish (polski) To use the sharing features on this page, ...
Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne
2016-09-01
Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Jankowski, Piotr; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek
2015-01-01
Chronic total occlusions (CTO) are diagnosed in about 20% of patients with significant coronary artery disease. A disproportion between the high prevalence of CTOs and low rate of invasive treatment still exists. Technical difficulties, clinical uncertainties whether patients benefit from recanalisation, and a lack of knowledge of CTO may be responsible for this fact. To assess the knowledge of coronary arteries CTO among Polish interventional cardiologists. A self-designed questionnaire was used during two major Polish invasive cardiology workshops held in 2014. The study included 113 physicians, mostly cardiologists certified as independent operators. Average self-declared efficacy of CTO recanalisation was 63.5%. Most of the respondents agreed that the operator involved in the CTO recanalisation program should perform at least 30-50 procedures per year. Only 67% stated that before CTO revascularisation the evaluation of myocardial viability should be performed with dobutamine stress echocardiography as a preferred test. One third of the physicians agreed that CTO percutaneous coronary intervention (PCI) should not be performed directly after diagnostic angiography, and 51.5% believed that in patients with multi-vessel coronary artery disease PCI of CTO should be performed first. Multi-slice spiral computed tomography during the qualification and planning of the CTO revascularisation, in the opinion of 91% of the responders, should not be used before each procedure but could be useful in selected cases. Polish interventional cardiologists remains in compliance with current opinions about recanalisation of chronic coronary artery occlusions and the consensus of the EuroCTO Club, but there is still an unceasing need for further education and promotion of knowledge about CTOs.
Effects of different preparation procedures during tooth whitening on enamel bonding.
Wilson, Dustin; Xu, Changqi; Hong, Liang; Wang, Yong
2009-04-01
The objective of this study was to assess effects of some clinically related preparation procedures during tooth whitening on enamel bonding properties. Sixty-two extracted human teeth were cleaned and divided into four groups. Forty-two of the teeth were left with their natural surface intact while 20 teeth were polished to form a flat surface. Half of the tooth served as the experimental side and received one of the two whitening products: Opalescence (10% carbamide peroxide) and Crest Whitestrips (6.5% hydrogen peroxide), for 2 weeks. Post-bleaching intervals included: 1 day, 1 week, and 2 weeks. On these days, tooth (10 mm x 1.5 mm x 1.5 mm) sections were evaluated using Raman spectroscopy, scanning electron microscopy and tensile bond strength tests. T-test, ANOVA test, and mixed model regression analysis were used to assess the differences. No significant difference existed between natural surface and polished surface teeth for all groups at both Day One and Week Two (P > 0.05). On Day One, both treated groups had significant lower bond strength than the control group (P = 0.002). After 2 weeks, no significant difference existed between any group (P = 0.381). SEM indicated that resin-enamel interfaces in bleached enamel exhibited more defects in granular formations when compared to the control. Raman results indicated a lower degree of polymerization (DP) of adhesive at the interface for treated teeth surfaces. In summary, pre-bleaching surface treatments such as polish or non-polish, had no effect on bond strength. Bleaching significantly decreased bond strength initially, but after 2 weeks, bleaching had no significant effect on bond strength. Storage time had significant effect on Opalescence treated enamel, but not on control and Whitestrip treated enamel. The decrease of bond strength may be related to interfacial defects and low DP due to oxygen release after bleaching.
Strain-free polished channel-cut crystal monochromators: a new approach and results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasman, Elina; Montgomery, Jonathan; Huang, XianRong
The use of channel-cut crystal monochromators has been traditionally limited to applications that can tolerate the rough surface quality from wet etching without polishing. We have previously presented and discussed the motivation for producing channel cut crystals with strain-free polished surfaces [1]. Afterwards, we have undertaken an effort to design and implement an automated machine for polishing channel-cut crystals. The initial effort led to inefficient results. Since then, we conceptualized, designed, and implemented a new version of the channel-cut polishing machine, now called C-CHiRP (Channel-Cut High Resolution Polisher), also known as CCPM V2.0. The new machine design no longer utilizesmore » Figure-8 motion that mimics manual polishing. Instead, the polishing is achieved by a combination of rotary and linear functions of two coordinated motion systems. Here we present the new design of C-CHiRP, its capabilities and features. Multiple channel-cut crystals polished using the C-CHiRP have been deployed into several beamlines at the Advanced Photon Source (APS). We present the measurements of surface finish, flatness, as well as topography results obtained at 1-BM of APS, as compared with results typically achieved when polishing flat-surface monochromator crystals using conventional polishing processes. Limitations of the current machine design, capabilities and considerations for strain-free polishing of highly complex crystals are also discussed, together with an outlook for future developments and improvements.« less
Wang, Yu-guang; Xing, Yan-xi; Sun, Yu-chun; Zhao, Yi-jiao; Lü, Pei-jun; Wang, Yong
2013-06-01
To evaluate clinical effects of computer aided design and computer aided manufacturing (CAD/CAM) milled zirconia crown in three aspects: aesthetic, contact wear and fracture. Sixty patients were divided into two groups.In one group, 35 full contour CAD/CAM zirconia crown were made on molars of 30 patients. The manufacturing process of zirconia crown was as follow. First, the three dimensional(3-D) data of working models, antagonist impression and check records were acquired by 3-D laser scanning Dental wings S50. Then full contour zirconia crowns, which had functional occlusal contacts with antagonistic teeth, and appropriate contact with adjacent teeth were designed with Zeno-CAD(V4.2.5.5.12919) software. ZENOSTAR Zr pure zirconia material was milled in digital controlled machine WIELAND 4030 M1.In the end, the zirconia crown were completed with the method of second sintering and polishing. After clinical try-in, the crown was cemented.In the control group, thirty gold alloy full crown were made and cemented on molars of 30 patients. According to the modified U S Public Health Service Criteria(USPHS) evaluation standard, all crowns were evaluated on the same day, at three months, half a year, one year and two years following delivery. There were three aspects we were focusing on in the evaluation: aesthetic, contact wear(restoration and antagonist), and fracture. In all the prosthesis we evaluated during the 24 months, no fracture was found. Contact wear of crowns varies according to different antagonist teeth. The zirconia crowns show privilege in aesthesis, toughness and anti-wearing.However, there is contact wear on antagonistic natural teeth. Thus it is a good choice when full zirconia crowns are indicated on two antagonistic teeth in both jaws.
Alp, Gulce; Subasi, Meryem Gulce; Johnston, William M; Yilmaz, Burak
2018-03-15
The effects of surface treatments and coffee thermocycling on the color and relative translucency of a recently introduced computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic glass-ceramic are unknown. The purpose of this in vitro study was to evaluate the effect of coffee thermocycling on the color and relative translucency parameter (RTP) of CAD-CAM monolithic glass-ceramics after different surface treatments. Specimens (1.5-mm-thick) were sectioned from zirconia-reinforced lithium silicate glass-ceramic (ZLS) (n=18) and lithium disilicate glass-ceramic (LDS) blocks (n=18). Two different types of surface treatments (glazing or polishing) were applied to the specimens. The specimens were subjected to 5000 thermocycles in a coffee solution. The color coordinates of specimens were measured before and after coffee thermocycling by using a spectroradiometer, and color differences and relative translucency values were calculated by using CIEDE2000 color difference and RTP formulas. ANOVA was used to analyze the color difference and relative translucency values by using maximum likelihood estimation and the Satterthwaite degrees of freedom methods. Any significant interaction between surface subgroups was further analyzed by using the Tukey-Kramer adjustment (α=.05). Material type had a significant effect on color difference (P=.018). All color difference values of all materials were smaller than the clinical acceptability threshold (<1.8 units). For relative translucency, material (P<.001) and coffee thermocycling had a significant effect (P=.014), and an interaction was found between the surface treatments and materials (P<.001). The Tukey-Kramer test revealed significant differences between glazed and polished subgroups of LDS material, except for ZLS-glazed and ZLS-polished subgroups. Different surface treatments of CAD-CAM monolithic zirconia-reinforced lithium silicate and lithium disilicate glass-ceramics resulted in clinically acceptable color changes after coffee thermocycling. The color changes in all groups, except for LDS-polished, were not perceivable. Lithium disilicate was more translucent than zirconia-reinforced lithium silicate before and after coffee thermocycling. Coffee thermocycling decreased the translucency of both of the materials. Different surface treatments affected the translucency of only lithium disilicate for tested thickness. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Jaroszynska-Kirchmann, Anna D.
2008-01-01
"Ameryka-Echo" was one of the most popular Polish-language weeklies, published in the United States between 1889 and 1972. Its founder and owner, Antoni A. Paryski, consciously sought to transplant ideas of Polish Positivism to the Polish-American immigrant communities in the United States. Reading was a central concept of…
Perceptions of and Attitudes towards Regional Varieties of Polish: Views from Two Polish Provinces
ERIC Educational Resources Information Center
Milobog, Magdalena; Garrett, Peter
2011-01-01
This paper reports a study of perceptions and attitudes relating to regional varieties of Polish. The methodology followed folk linguistic approaches to attitudes research. Respondents in two Polish provinces were asked to draw on a map of Poland where they thought the main regional varieties of Polish were spoken, and then to name and…
Madhyastha, Prashanthi Sampath; Hegde, Shreya; Srikant, N; Kotian, Ravindra; Iyer, Srividhya Sriraman
2017-01-01
Surface roughness associated with improper finishing/polishing of restorations can result in plaque accumulation, gingival irritation, surface staining, and poor esthetic of restored teeth. The study aimed to evaluate the efficiency of various finishing and polishing systems and time using various procedures on surface roughness of some esthetic restorative materials. In this in vitro study, samples of two composite materials, compomer and glass ionomer cement (GIC) materials, were fabricated. Finishing and polishing were done immediately ( n = 40) and after 1 week ( n = 40) using four systems (diamond bur + soflex discs; diamond bur + Astropol polishing brush; tungsten carbide bur + soflex discs; tungsten carbide bur + Astropol polishing brush). Surface roughness was measured using surface profilometer. Data were statistically analyzed by t -test (for each material and time period) and one-way analysis of variance followed by Tukey's post hoc (for finishing and polishing systems) at a significant level of P < 0.05. Analysis of time period, irrespective of finishing and polishing system showed that Ra values were greater ( P < 0.05) in delayed polishing in GIC > Z100 > Filtek P90 > Dyract AP, suggesting immediate polishing is better. Among the materials, Filtek P90 had the least Ra values indicating the smoothest surface among all materials, followed by Z100, Dyract AP, and GIC. Comparison of polishing and finishing systems irrespective of materials showed that Ra values were lower ( P > 0.05) in diamond + Astropol combination whereas diamond + soflex had the greatest Ra values. It might be concluded that: (i) Filtek P90 showed least Ra values followed by < Z100 < Dyract < GIC; (ii) immediate (24 h) finishing/polishing of materials is better than delayed; and (iii) among all these polishing systems, diamond bur-Astropol and Astrobrush showed good surface finish.
Knowledge of chronic total occlusion among Polish interventional cardiologists
Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek
2015-01-01
Introduction Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. Aim An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Material and methods Questionnaire survey performed during two major Polish invasive cardiology workshops. Results In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Conclusions Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient. PMID:26161099
Kurzawińska, Grażyna; Barlik, Magdalena; Drews, Krzysztof; Różycka, Agata; Seremak-Mrozikiewicz, Agnieszka; Ożarowski, Marcin; Klejewski, Andrzej; Czerny, Bogusław; Wolski, Hubert
2016-01-01
Recurrent miscarriage (RM) is one of the most common obstetric complications. Numerous studies have suggested that genetic variants leading to an impaired balance between coagulation and fibrinolysis may contribute to elevated risk of pregnancy loss. The aim of the study was to investigate a possible association between angiotensin-converting enzyme (ACE, rs1799752) I/D and plasminogen activator inhibitor type 1 (PAI-1, rs1799768) 4G/5G polymorphisms with RM among Polish women. DNA was extracted from peripheral blood samples of 152 women with a history of ≥ 2 consecutive pregnancy losses before 22 weeks of gestation, and 180 healthy controls with at least 1 live birth at term and no history of pregnancy loss. Polymerase chain reaction (PCR) and restriction fragment length polymorphism (RFLP) were used to identify the polymorphisms. No statistically significant differences were found in genotype and allele frequencies of the studied polymorphisms. The most relevant difference between the study group and controls was found for the ID genotype distribution of the ACE gene (52.6 vs. 46.7%, OR = 1.27, p = 0.28). The analysis of genotype coexistence revealed a higher incidence of the combination of the ACE II and the PAI-1 4G/4G genotypes in the control group (10.0 vs.5.9% in control group; p = 0.17). The obtained results suggest no apparent association between the ACE I/D, PAI-1 4G/5G polymorphisms and increased RM susceptibility in the analyzed Polish population.
The Incidence of Hypogonadotropic Hypogonadism in Type 2 Diabetic Men in Polish Population
Rabijewski, Michał; Zgliczyński, Wojciech; Piątkiewicz, Paweł
2013-01-01
The aim of this study was to investigate the incidence of hypogonadotropic hypogonadism (HH) in type 2 diabetic men (T2DM) in population of Polish men and examine the possible influence of estradiol levels and glycemic control. We evaluated TT, cfT, estradiol, and glycemic control (HbA1c) in 184 diabetic men and in 149 nondiabetic control group. The mean HbA1c was 8.6 ± 0.2% and 6.1 ± 0.3% and cfT concentration was 0.315 ± 0.08 nmol/L and 0.382 ± 0.07 nmol/L, respectively. T2DM had higher E2 concentration than nonobese control men (29.4 ± 3.7 pg/mL versus 24.5 ± 2.9 pg/mL). Forty-six percent of T2DM were hypogonadal and 93% had HH. We observed inverse relationship between BMI and cfT (r = −0.341, P < 0.01) and positive between BMI and E2 (r = 0.329, P < 0.01). E2 concentration was higher in T2DM with HH versus T2DM with normal TT/cfT concentration (34.5 ± 5.2 versus 27.4 ± 3.4 pg/mL). We observed negative correlation between HbA1c and cfT (r = −0.336, P < 0.005) but positive between HbA1c and E2 levels (r = 0.337, P < 0.002). The prevalence of obesity, hypertension, and CVD was higher in men with hypogonadism. High incidence of hypogonadotropic hypogonadism in type 2 diabetic men in Polish population is associated with poor glycemic control and can be secondary to an increase in estradiol concentrations. PMID:24222915
[Mental health of Polish immigrants compared to that of the Polish and German populations].
Morawa, Eva; Senf, Wolfgang; Erim, Yesim
2013-01-01
This survey examines the mental health of immigrants of Polish origin compared to samples from the Polish and German populations. In a sample of 513 subjects (261 persons with Polish migration background and 252 autochthone Poles) depression (BDI), anxiety (BAI), and somatic complaints (GBB-24) were measured. Immigrants of Polish origin showed a significantly higher level of anxiety as well as somatic complaints but only a tendency toward higher depressiveness than the German normvalue, but not than that of the native Poles. Female immigrants showed an overall higher number of symptoms in the three domains in question compared to German women and - except for depressiveness - also compared to male immigrants. Persons with a Polish migration background present levels of mental distress higher than the general German population, but similar to the population of their country of origin. Further research is needed to clarify the special structure of the mental morbidity in Polish immigrants.
The Military Technology of the Polish People’s Army, 30 Years of Development,
1983-12-20
armed with light self - propelled cannon mounted on tracked vehicles (adapted also to transport aircraft) as well as recoilless guns with...with radar-computers, mounted on self propelled tracked vehicles . The modernization of artillery has led to the expansion of technical-repair...light tracked vehicles and on self propelled areal vehicles . 4 . , A very important factor influencing the improvement of the effectiveness of artillery
Kemaloglu, Hande; Karacolak, Gamze; Turkun, L Sebnem
2017-02-01
The aim of this study was to evaluate the effects of various finishing and polishing systems on the final surface roughness of a resin composite. Hypotheses tested were: (1) reduced-step polishing systems are as effective as multiple-step systems on reducing the surface roughness of a resin composite and (2) the number of application steps in an F/P system has no effect on reducing surface roughness. Ninety discs of a nano-hybrid resin composite were fabricated and divided into nine groups (n = 10). Except the control, all of the specimens were roughened prior to be polished by: Enamel Plus Shiny, Venus Supra, One-gloss, Sof-Lex Wheels, Super-Snap, Enhance/PoGo, Clearfil Twist Dia, and rubber cups. The surface roughness was measured and the surfaces were examined under scanning electron microscope. Results were analyzed with analysis of variance and Holm-Sidak's multiple comparisons test (p < 0.05). Significant differences were found among the surface roughness of all groups (p < 0.05). The smoothest surfaces were obtained under Mylar strips and the results were not different than Super-Snap, Enhance/PoGo, and Sof-Lex Spiral Wheels. The group that showed the roughest surface was the rubber cup group and these results were similar to those of the One-gloss, Enamel Plus Shiny, and Venus Supra groups. (1) The number of application steps has no effect on the performance of F/P systems. (2) Reduced-step polishers used after a finisher can be preferable to multiple-step systems when used on nanohybrid resin composites. (3) The effect of F/P systems on surface roughness seems to be material-dependent rather than instrument- or system-dependent. Reduced-step systems used after a prepolisher can be an acceptable alternative to multiple-step systems on enhancing the surface smoothness of a nanohybrid composite; however, their effectiveness depends on the materials' properties. (J Esthet Restor Dent 29:31-40, 2017). © 2016 Wiley Periodicals, Inc.
Wujcicka, Wioletta; Wilczyński, Jan; Nowakowska, Dorota
2017-09-01
The research was conducted to evaluate the role of genotypes, haplotypes and multiple-SNP variants in the range of TLR2, TLR4 and TLR9 single nucleotide polymorphisms (SNPs) in the development of Toxoplasma gondii infection among Polish pregnant women. The study was performed for 116 Polish pregnant women, including 51 patients infected with T. gondii, and 65 age-matched control pregnant individuals. Genotypes in TLR2 2258 G>A, TLR4 896 A>G, TLR4 1196 C>T and TLR9 2848 G>A SNPs were estimated by self-designed, nested PCR-RFLP assays. Randomly selected PCR products, representative for distinct genotypes in the studied polymorphisms, were confirmed by sequencing. All the genotypes were calculated for Hardy-Weinberg (H-W) equilibrium and TLR4 variants were tested for linkage disequilibrium. Relationships were assessed between alleles, genotypes, haplotypes or multiple-SNP variants in TLR polymorphisms and the occurrence of T. gondii infection in pregnant women, using a logistic regression model. All the analyzed genotypes preserved the H-W equilibrium among the studied groups of patients (P>0.050). Similar distribution of distinct alleles and individual genotypes in TLR SNPs, as well as of haplotypes in TLR4 polymorphisms, were observed in T. gondii infected and control uninfected pregnant women. However, the GACG multiple-SNP variant, within the range of all the four studied polymorphisms, was correlated with a decreased risk of the parasitic infection (OR 0.52, 95% CI 0.28-0.97; P≤0.050). The polymorphisms, located within TLR2, TLR4 and TLR9 genes, may be involved together in occurrence of T. gondii infection among Polish pregnant women. Copyright © 2017 Medical University of Bialystok. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Menapace, Joseph A.
2010-11-01
Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm2 at 1053 nm), visible (>18 J/cm2 at 527 nm), and ultraviolet (>10 J/cm2 at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chain or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture largeaperture damage resistant optics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A
2010-10-27
Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm{sup 2} at 1053 nm), visible (>18 J/cm{sup 2} at 527 nm), and ultraviolet (>10 J/cm{sup 2} at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chainmore » or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large-aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture large-aperture damage resistant optics.« less
Effect of the Polishing Procedures on Color Stability and Surface Roughness of Composite Resins
Schmitt, Vera Lucia; Puppin-Rontani, Regina Maria; Naufel, Fabiana Scarparo; Nahsan, Flávia Pardo Salata; Alexandre Coelho Sinhoreti, Mário; Baseggio, Wagner
2011-01-01
Objectives. To evaluate the polishing procedures effect on color stability and surface roughness of composite resins. Methods. Specimens were distributed into 6 groups: G1: Filtek Supreme XT + PoGo; G2: Filtek Supreme XT + Sof-Lex; G3: Filtek Supreme XT + no polishing; G4: Amelogen + PoGo; G5: Amelogen + Sof-Lex.; G6: Amelogen + no polishing. Initial color values were evaluated using the CIELab scale. After polishing, surface roughness was evaluated and the specimens were stored in coffee solution at 37°C for 7 days. The final color measurement and roughness were determined. Results. Sof-Lex resulted in lower staining. Amelogen showed the highest roughness values than Filtek Supreme on baseline and final evaluations regardless of the polishing technique. Filtek Supreme polished with PoGo showed the lowest roughness values. All groups presented discoloration after storage in coffee solution, regardless of the polishing technique. Conclusion. Multiple-step polishing technique provided lower degree of discoloration for both composite resins. The final surface texture is material and technique dependent. PMID:21991483
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Hui; Endo, Katsuyoshi; Yamamura, Kazuya, E-mail: yamamura@upst.eng.osaka-u.ac.jp
2015-08-03
Chemical mechanical polishing (CMP) combined with atmospheric-pressure plasma pretreatment was applied to a GaN (0001) substrate. The irradiation of a CF{sub 4}-containing plasma was proven to be very useful for modifying the surface of GaN. When CMP was conducted on a plasma-irradiated surface, a modified layer of GaF{sub 3} acted as a protective layer on GaN by preventing the formation of etch pits. Within a short duration (8 min) of CMP using a commercially available CeO{sub 2} slurry, an atomically flat surface with a root mean square (rms) roughness of 0.11 nm was obtained. Moreover, etch pits, which are inevitably introduced inmore » conventional CMP, could not be observed at the dislocation sites on the polished GaN surface. It was revealed that CMP combined with the plasma pretreatment was very effective for obtaining a pit-free and atomically flat GaN surface.« less
Tuomi, Jukka T; Björkstrand, Roy V; Pernu, Mikael L; Salmi, Mika V J; Huotilainen, Eero I; Wolff, Jan E H; Vallittu, Pekka K; Mäkitie, Antti A
2017-03-01
Custom-designed patient-specific implants and reconstruction plates are to date commonly manufactured using two different additive manufacturing (AM) technologies: direct metal laser sintering (DMLS) and electron beam melting (EBM). The purpose of this investigation was to characterize the surface structure and to assess the cytotoxicity of titanium alloys processed using DMLS and EBM technologies as the existing information on these issues is scarce. "Processed" and "polished" DMLS and EBM disks were assessed. Microscopic examination revealed titanium alloy particles and surface flaws on the processed materials. These surface flaws were subsequently removed by polishing. Surface roughness of EBM processed titanium was higher than that of DMLS processed. The cytotoxicity results of the DMLS and EBM discs were compared with a "gold standard" commercially available titanium mandible reconstruction plate. The mean cell viability for all discs was 82.6% (range, 77.4 to 89.7) and 83.3% for the control reconstruction plate. The DMLS and EBM manufactured titanium plates were non-cytotoxic both in "processed" and in "polished" forms.
Effect of bleaching agent and topical fluoride application on color and gloss of dental ceramics.
Pires-de-Souza, Fernanda de Carvalho Panzeri; Contente, Marta Maria Martins Giamatei; Alandia-Román, Carla Cecilia; Vicente, Sergio Augusto de Freitas; Tonani, Rafaella
2016-01-01
The aim of this study was to evaluate the effect of 16% carbamide peroxide and 1.23% acidulated phosphate fluoride application and their association with a change in color (ΔE*) and brightness of dental ceramic submitted to different finishing procedures. A total of 120 test specimens were fabricated and randomly divided into 3 groups (n = 40) according to the type of finishing: glazing; polishing; or polishing and glazing. Initial color and brightness readouts were taken, and the finished specimens were divided into groups (n = 10) according to the treatment to which they were submitted: fluoride; bleaching; bleaching and fluoride; or control. After this, final color and brightness readouts were taken. The type of polishing had no influence on ΔE* or brightness (P > 0.05). Regardless of which solution was used, a decrease in brightness occurred only for the group treated with bleach and fluoride (P < 0.05). The results showed the use of fluoride after bleaching may interfere with the esthetics of a restoration.
Removing Silicon Monoxide From Nickel Mirrors
NASA Technical Reports Server (NTRS)
Zaniewski, John J.
1987-01-01
Combination of polishing tool and polishing mixture used to remove adherent fragments of silicon monoxide protective coatings from nickel/aluminum mirrors without altering shapes or harming polishes of mirror surfaces. Polishing technique developed to prepare stained mirrors for recoating to restore high reflectance.
ERIC Educational Resources Information Center
Miekisz, Aneta; Haman, Ewa; Luniewska, Magdalena; Kus, Katarzyna; O'Toole, Ciara; Katsos, Napoleon
2017-01-01
The expressive lexical skills of 53 Polish bilinguals aged 24-36 months living in the UK and Ireland were assessed using Polish and British English adaptations of the MacArthur-Bates Communicative Development Inventories. Polish vocabulary scores were compared to those of 53 Polish monolinguals matched for age, gender and parental education. The…
Cancer morbidity among polishers.
Järvholm, B; Thiringer, G; Axelson, O
1982-01-01
The mortality pattern among 86 men was determined to investigate the possible hazards of polishing steel. The men had polished steel with polishing paste for at least five years. The polishing pastes had contained tallow, beeswax, carnauba wax, alundum, carborundum, ferric oxide, and chalk. A total of 18 men had died compared with 13.3 expected. Four had died of stomach cancer compared with 0.44 expected (p less than 0.005). The mortality for other causes of death was not increased. The study does not permit any definite conclusion but indicates a possible cancer hazard among polishers. PMID:7066237
Bacterial carriage on the fingernails of OR nurses.
Wynd, C A; Samstag, D E; Lapp, A M
1994-11-01
This study provides statistically significant data that demonstrate that chipped fingernail polish or fingernail polish worn longer than four days fosters increased numbers of bacteria on the fingernails of OR nurses after surgical hand scrubs. There were no significant correlations between fingernail length and the numbers of bacterial colonies on the fingernails of the study groups tested after performing a standard surgical hand scrub. A convenience sample of 102 perioperative nurses with either freshly polished fingernails; chipped fingernail polish; or natural, polish-free fingernails participated. The data suggest OR nurses can wear fresh fingernail polish on healthy fingernails without risking increased bacterial counts.
NASA Astrophysics Data System (ADS)
Shi, Feng; Shu, Yong; Dai, Yifan; Peng, Xiaoqiang; Li, Shengyi
2013-07-01
Based on the elastic-plastic deformation theory, status between abrasives and workpiece in magnetorheological finishing (MRF) process and the feasibility of elastic polishing are analyzed. The relationship among material removal mechanism and particle force, removal efficiency, and surface topography are revealed through a set of experiments. The chemical dominant elastic super-smooth polishing can be fulfilled by changing the components of magnetorheological (MR) fluid and optimizing polishing parameters. The MR elastic super-smooth finishing technology can be applied in polishing high-power laser-irradiated components with high efficiency, high accuracy, low damage, and high laser-induced damage threshold (LIDT). A 430×430×10 mm fused silica (FS) optic window is polished and surface error is improved from 538.241 nm [peak to valley (PV)], 96.376 nm (rms) to 76.372 nm (PV), 8.295 nm (rms) after 51.6 h rough polishing, 42.6 h fine polishing, and 54.6 h super-smooth polishing. A 50×50×10 mm sample is polished with exactly the same parameters. The roughness is improved from 1.793 nm [roughness average (Ra)] to 0.167 nm (Ra) and LIDT is improved from 9.77 to 19.2 J/cm2 after MRF elastic polishing.
Hatamleh, Muhanad M; Wu, Xiaohong; Alnazzawi, Ahmad; Watson, Jason; Watts, David
2018-04-01
Surface and mechanical properties of titanium alloys are integral for their use in restoring bone defects of skull and face regions. These properties are affected by the method of constructing and surface treatment of the titanium implant. This study aimed to investigate the effects of titanium finishing protocols on the surface morphology, hardness and biocompatibility of TiAl6V4. Square shaped TiAl6V4 specimens (ASTM F68) (10×10×0.5mm) were divided into seven groups of different surface treatments (n=10). The treatments included mechanical polishing, sandblasting with AL 2 O 3 (50μm), immersion in different acids, and/or electro-chemical anodization. Weight loss %; 3D micro-roughness; Knoop micro-hardness, and osteoblast cell attachment and proliferation (after 3 days) were determined for each specimen. Data was analysed using one way ANOVA and Dunett T3 post-hoc tests, and t-test (p<0.05). Weight loss % was in the range of 1.70-5.60 as mechanical polishing produced the highest weight loss, followed by sandblasting, and combined protocol of mechanical polishing and acid treatment (p<0.05). Micro-roughness values (μm) were in the range of 2.81-16.68. It was the highest for control specimens (p<0.05), and smoothest surfaces after combined mechanical polishing and acid treatment; or after electro-chemical treatment (p<0.05). Micro-hardness values (MPa) ranged 170.90-442.15 as sandblasting with/without acid treatment caused statically significantly the highest values (p<0.05) while control and mechanically polished specimens had the lowest values (p<0.05). All treatments produced equally biocompatible surfaces (p>0.05) after 1h or 3 days. Furthermore, osteoblast cell proliferation statistically significantly increased after 3days among each surface treatment (p<0.05). Different finishing treatments have variable effect on cranioplasty titanium surface loss, micro-roughness and micro-hardness but constant improved biocompatibility effect. Electro-chemical treatment caused less material loss and produced biocompatible smoothest surface of comparable hardness; hence it can be suitable for cranioplasty titanium surface finishing. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jin, Zhang; Yuling, Liu; Chenqi, Yan; Yangang, He; Baohong, Gao
2016-04-01
The replacement metal gate (RMG) defectivity performance control is very challenging in high-k metal gate (HKMG) chemical mechanical polishing (CMP). In this study, three major defect types, including fall-on particles, micro-scratch and corrosion have been investigated. The research studied the effects of polishing pad, pressure, rotating speed, flow rate and post-CMP cleaning on the three kinds of defect, which finally eliminated the defects and achieved good surface morphology. This study will provide an important reference value for the future research of aluminum metal gate CMP. Project supported by the Major National Science and Technology Special Projects (No. 2009ZX02308), the Natural Science Foundation for the Youth of Hebei Province (Nos. F2012202094, F2015202267), and the Outstanding Youth Science and Technology Innovation Fund of Hebei University of Technology (No. 2013010).
Multiwavelength digital holography for polishing tool shape measurement
NASA Astrophysics Data System (ADS)
Lédl, Vít.; Psota, Pavel; Václavík, Jan; Doleček, Roman; Vojtíšek, Petr
2013-09-01
Classical mechano-chemical polishing is still a valuable technique, which gives unbeatable results for some types of optical surfaces. For example, optics for high power lasers requires minimized subsurface damage, very high cosmetic quality, and low mid spatial frequency error. One can hardly achieve this with use of subaperture polishing. The shape of the polishing tool plays a crucial role in achieving the required form of the optical surface. Often the shape of the polishing tool or pad is not known precisely enough during the manufacturing process. The tool shape is usually premachined and later is changed during the polishing procedure. An experienced worker could estimate the shape of the tool indirectly from the shape of the polished element, and that is why he can achieve the required shape in few reasonably long iterative steps. Therefore the lack of the exact tool shape knowledge is tolerated. Sometimes, this indirect method is not feasible even if small parts are considered. Moreover, if processes on machines like planetary (continuous) polishers are considered, the incorrect shape of the polishing pad could extend the polishing times extremely. Every iteration step takes hours. Even worse, polished piece could be wasted if the pad has a poor shape. The ability of the tool shape determination would be very valuable in those types of lengthy processes. It was our primary motivation to develop a contactless measurement method for large diffusive surfaces and demonstrate its usability. The proposed method is based on application of multiwavelength digital holographic interferometry with phase shift.
Polishing parameter optimization for end-surface of chalcogenide glass fiber connector
NASA Astrophysics Data System (ADS)
Guo, Fangxia; Dai, Shixun; Tang, Junzhou; Wang, Xunsi; Li, Xing; Xu, Yinsheng; Wu, Yuehao; Liu, Zijun
2017-11-01
We have investigated the optimization parameters for polishing end-surface of chalcogenide glass fiber connector in the paper. Six SiC abrasive particles of different sizes were used to polish the fiber in order of size from large to small. We analyzed the effects of polishing parameters such as particle sizes, grinding speeds and polishing durations on the quality of the fiber end surface and determined the optimized polishing parameters. We found that, high-quality fiber end surface can be achieved using only three different SiC abrasives. The surface roughness of the final ChG fiber end surface is about 48 nm without any scratches, spots and cracks. Such polishing processes could reduce the average insertion loss of the connector to about 3.4 dB.
Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.
Rodrigues-Junior, S A; Chemin, P; Piaia, P P; Ferracane, J L
2015-01-01
This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were manually finished with #400 sandpaper and polished by a single operator using three multistep systems (Superfix, Diamond Pro, and Sof-lex), one two-step system (Polidores DFL), and one one-step system (Enhance), following the manufacturer's instructions. The average surface roughness (μm) was measured with a surface profilometer (TR 200 Surface Roughness Tester), and gloss was measured using a small-area glossmeter (Novo-Curve, Rhopoint Instrumentation, East Sussex, UK). Data were analyzed by two-way analysis of variance and Tukey's test (α=0.05). Statistically significant differences in surface roughness were identified by varying the polishing systems (p<0.0001) and by the interaction between polishing system and composite (p<0.0001). Pairwise comparisons revealed higher surface roughness for Grandio when polished with Sof-Lex and Filtek Z250 and Opallis when polished with Enhance. Gloss was influenced by the composites (p<0.0001), the polishing systems (p<0.0001), and the interaction between them (p<0.0001). The one-step system, Enhance, produced the lowest gloss for all composites. Surface roughness and gloss were affected by composites and polishing systems. The interaction between both also influenced these surface characteristics, meaning that a single polishing system will not behave similarly for all composites. The multistep systems produced higher gloss, while the one-step system produced the highest surface roughness and the lowest gloss of all.
Steiner, René; Beier, Ulrike S; Heiss-Kisielewsky, Irene; Engelmeier, Robert; Dumfahrt, Herbert; Dhima, Matilda
2015-06-01
During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Examination of the polished surface character of fused silica.
Tesar, A A; Fuchs, B A; Hed, P P
1992-12-01
Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.
Examination of the polished surface character of fused silica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tesar, A.A.; Fuchs, B.A.; Hed, P.P.
1992-12-01
Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.
Influence of polishing on surface roughness following toothbrushing wear of composite resins.
Dalla-Vecchia, Karine Battestin; Taborda, Talita Damas; Stona, Deborah; Pressi, Heloísa; Burnett Júnior, Luiz Henrique; Rodrigues-Junior, Sinval Adalberto
2017-01-01
This study aimed to evaluate the influence of different polishing systems on the surface roughness of composite resins following procedures to simulate the effects of toothbrushing over time. Four currently available commercial composites were used to make 128 cylindrical specimens. The specimens were randomly allocated to polishing with a 1-step polisher or 1 of 3 multistep polishers (n = 8 per group). The baseline surface roughness was measured, and the specimens were submitted to 5000, 10,000, and 20,000 brushing cycles to represent toothbrushing throughout 6, 12, and 24 months, respectively. Results showed that surface roughness was influenced by the type of composite and polishing system and was not influenced by the simulated toothbrushing time. However, the surface roughness, as challenged by toothbrushing wear, was affected by the interaction among the composite, the polisher, and the toothbrushing time. The 1-step polisher produced the highest surface roughness and influenced toothbrushing wear resistance of some composites.
Al-Haj Husain, Nadin; Camilleri, Josette; Özcan, Mutlu
2016-12-01
Polishing procedures might alter monolithic zirconia (MZ) surface resulting in phase changes that can be deleterious for clinical performance and antagonist tooth wear. This study investigated the topographical features and phase transformation in MZ after polishing with different regimens simulating the clinical workflow. MZ specimens (Katana Zirconia HT, Kuraray-Noritake) (12×12×1.8 mm(3)) were grinded and polished using one of the five systems assessed: BG: Silicone carbide polishers (Brownie, Greenie, Super Greenie); CG: Diamond impregnated ceramic polisher kit (Ceragloss); EV: Synthetically bonded grinder interspersed with diamond (EVE Kit); SL: Urethane coated paper with aluminium oxide grits (Soflex Finishing and Polishing System Kit) and DB: Diamond bur (8 µm). Polished specimens were initially roughened with 220 µm diamond burs (Grinding Bur-GB) (10 s, 160.000160,000 rpm) and considered for baseline measurements. Polishing regimens were performed for 10 s using a slow-speed hand piece under water-cooling except for SL, in a custom made device (750 g; 5000 and 75,000 rpm). Surface roughnesses, phase changes (XRD) were assessed, surface characterization was performed (SEM, EDS). The highest roughness was obtained with the EV system (1.11 µm) compared to those of other systems (0.13-0.4 µm) (pθ and minor peak at 34.94°2θ. While GB, CG, EV, SL and DB exhibited a peak shift to the left, BG demonstrated a right peak shift on the 2θ scale. Monoclinic phase change was not noted in any of the groups. All polishing methods, except BG, exhibited a peak shift towards the lower angles of the 2-theta scale. Since the peak shifts were in the order of fractions of an angle they are attributed to stress formation rather than a phase change in the material. Thus, all polishing systems tested may not be detrimental for the phase transformation of MZ. EV system resulted in the highest roughness and none of the polishing regimens restored the polishability to the baseline level. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pseudo-random tool paths for CNC sub-aperture polishing and other applications.
Dunn, Christina R; Walker, David D
2008-11-10
In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.
Saiki, Osamu; Koizumi, Hiroyasu; Akazawa, Nobutaka; Kodaira, Akihisa; Okamura, Kentaro; Matsumura, Hideo
2016-01-01
This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).
Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics.
Fraga, Sara; Amaral, Marina; Bottino, Marco Antônio; Valandro, Luiz Felipe; Kleverlaan, Cornelis Johannes; May, Liliana Gressler
2017-11-01
To assess the effect of machining on the flexural fatigue strength and on the surface roughness of different computer-aided design, computer-aided manufacturing (CAD/CAM) ceramics by comparing machined and polished after machining specimens. Disc-shaped specimens of yttria-stabilized polycrystalline tetragonal zirconia (Y-TZP), leucite-, and lithium disilicate-based glass ceramics were prepared by CAD/CAM machining, and divided into two groups: machining (M) and machining followed by polishing (MP). The surface roughness was measured and the flexural fatigue strength was evaluated by the step-test method (n=20). The initial load and the load increment for each ceramic material were based on a monotonic test (n=5). A maximum of 10,000 cycles was applied in each load step, at 1.4Hz. Weibull probability statistics was used for the analysis of the flexural fatigue strength, and Mann-Whitney test (α=5%) to compare roughness between the M and MP conditions. Machining resulted in lower values of characteristic flexural fatigue strength than machining followed by polishing. The greatest reduction in flexural fatigue strength from MP to M was observed for Y-TZP (40%; M=536.48MPa; MP=894.50MPa), followed by lithium disilicate (33%; M=187.71MPa; MP=278.93MPa) and leucite (29%; M=72.61MPa; MP=102.55MPa). Significantly higher values of roughness (Ra) were observed for M compared to MP (leucite: M=1.59μm and MP=0.08μm; lithium disilicate: M=1.84μm and MP=0.13μm; Y-TZP: M=1.79μm and MP=0.18μm). Machining negatively affected the flexural fatigue strength of CAD/CAM ceramics, indicating that machining of partially or fully sintered ceramics is deleterious to fatigue strength. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Bladder cancer and occupation: a case-control study in northern Italy.
Porru, S; Aulenti, V; Donato, F; Boffetta, P; Fazioli, R; Cosciani Cunico, S; Alessio, L
1996-01-01
OBJECTIVES--A hospital based case-control study was conducted between 1992 and 1993 in the province of Brescia, a highly industrialised area in northern Italy, to evaluate occupational risk factors of bladder cancer. METHODS--The study evaluated 355 histologically confirmed cases of bladder cancer (275 men, 80 women) and 579 controls affected by urological non-neoplastic diseases (397 men, 182 women). Lifetime occupational history, smoking and drinking habits, and sociodemographic characteristics were recorded by means of a structured questionnaire. Odds ratios (ORs) were computed with adjustment for age, smoking, alcohol and coffee consumption, education, and place of residence. RESULTS--A significant (P < 0.05) increase of risk of bladder cancer were found in men for labourers in the construction industry (OR 2.1, 95% confidence interval (95% CI) 1.1-3.9) and for recreational and cultural services (OR 5.0, 95% CI 1.3-18.9). Increased risks, although not significant, were found for various other occupations and industries such as machinery mechanics, metal processers and polishers, blacksmiths, gunsmiths, painters; for transport workers, an increased risk with increasing duration of employment was found. CONCLUSIONS--Occupational exposures seem to contribute to bladder cancer risk in the area under study. PMID:8563860
Polish Higher Education: Intersectoral Distinctiveness
ERIC Educational Resources Information Center
Musial, Joanna
2014-01-01
This study analyzes degrees of differences between the private and public sectors of Polish higher education. It finds them to be strong: Polish private institutions function very differently from Polish public institutions and these differences correspond with those found in the literature on higher education elsewhere in the world. Polish…
ERIC Educational Resources Information Center
Bidwell, Charles E.
This volume, one of a series of concise but relatively exhaustive descriptions of the grammatical structures of the principal standard Slavic languages, contains an outline of Polish morphology. The four major sections are morphophonemics, nominal inflection, the Polish verb (Part 1--stem alternation and conjugation, and the Polish verb (Part…
A Force-Controllable Macro-Micro Manipulator and its Application to Medical Robotics
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Uecker, Darrin R.; Wang, Yulun
1993-01-01
This paper describes an 8-degrees-of-freedom macro-micro robot. This robot is capable of performing tasks that require accurate force control, such as polishing, finishing, grinding, deburring, and cleaning. The design of the macro-micro mechanism, the control algorithms, and the hardware/sofware implemtation of the algotithms are described in this paper. Initial experimental results are reported.
... of illegal drugs Carbon monoxide from gas appliances Household products, such as laundry powder or furniture polish Pesticides ... products exactly as their labels say. Keep dangerous products where children ... call your local poison control center at 1-800-222-1222 right away.
Optimization of IBF parameters based on adaptive tool-path algorithm
NASA Astrophysics Data System (ADS)
Deng, Wen Hui; Chen, Xian Hua; Jin, Hui Liang; Zhong, Bo; Hou, Jin; Li, An Qi
2018-03-01
As a kind of Computer Controlled Optical Surfacing(CCOS) technology. Ion Beam Figuring(IBF) has obvious advantages in the control of surface accuracy, surface roughness and subsurface damage. The superiority and characteristics of IBF in optical component processing are analyzed from the point of view of removal mechanism. For getting more effective and automatic tool path with the information of dwell time, a novel algorithm is proposed in this thesis. Based on the removal functions made through our IBF equipment and the adaptive tool-path, optimized parameters are obtained through analysis the residual error that would be created in the polishing process. A Φ600 mm plane reflector element was used to be a simulation instance. The simulation result shows that after four combinations of processing, the surface accuracy of PV (Peak Valley) value and the RMS (Root Mean Square) value was reduced to 4.81 nm and 0.495 nm from 110.22 nm and 13.998 nm respectively in the 98% aperture. The result shows that the algorithm and optimized parameters provide a good theoretical for high precision processing of IBF.
Automatic flatness detection system for micro part
NASA Astrophysics Data System (ADS)
Luo, Yi; Wang, Xiaodong; Shan, Zhendong; Li, Kehong
2016-01-01
An automatic flatness detection system for micro rings is developed. It is made up of machine vision module, ring supporting module and control system. An industry CCD camera with the resolution of 1628×1236 pixel, a telecentric with magnification of two, and light sources are used to collect the vision information. A rotary stage with a polished silicon wafer is used to support the ring. The silicon wafer provides a mirror image and doubles the gap caused by unevenness of the ring. The control system comprise an industry computer and software written in LabVIEW Get Kernel and Convolute Function are selected to reduce noise and distortion, Laplacian Operator is used to sharp the image, and IMAQ Threshold function is used to separate the target object from the background. Based on this software, system repeating precision is 2.19 μm, less than one pixel. The designed detection system can easily identify the ring warpage larger than 5 μm, and if the warpage is less than 25 μm, it can be used in ring assembly and satisfied the final positionary and perpendicularity error requirement of the component.
The advancement of the high precision stress polishing
NASA Astrophysics Data System (ADS)
Li, Chaoqiang; Lei, Baiping; Han, Yu
2016-10-01
The stress polishing is a kind of large-diameter aspheric machining technology with high efficiency. This paper focuses on the principle, application in the processing of large aspheric mirror, and the domestic and foreign research status of stress polishing, aimed at the problem of insufficient precision of mirror surface deformation calculated by some traditional theories and the problem that the output precision and stability of the support device in stress polishing cannot meet the requirements. The improvement methods from these three aspects are put forward, the characterization method of mirror's elastic deformation in stress polishing, the deformation theory of influence function and the calculation of correction force, the design of actuator's mechanical structure. These improve the precision of stress polishing and provide theoretical basis for the further application of stress polishing in large-diameter aspheric machining.
Surface geometry of three packable and one hybrid composite after polishing.
Jung, Martin; Bruegger, Hilka; Klimek, Joachim
2003-01-01
This study evaluated the surface quality of four composite materials after polishing with six different polishing techniques. Eighty specimens were made using three packable composites (Definite/Degussa, SureFil/ Dentsply and Solitaire/Heraeus-Kulzer) and one hybrid composite (Herculite XRV/Kerr). Five specimens of each material were polished using flexible Sof-Lex discs. The remaining 75 specimens of each composite were prepared using three finishing protocols: a single 30 microm diamond (n = 25), two finishing diamonds (30/20 microm; n = 25) and a 30 microm diamond followed by a tungsten carbide finishing bur (n = 25). Final polishing of each of the three finishing groups was accomplished with SuperBuff, Diafix-oral, OneGloss, Astropol and HaWe Composite Polishers (n = 5, each). Surface roughness was evaluated quantitatively by laser-stylus profilometry. Average roughness (R(a)) was calculated; statistical analysis of the data was performed with two-way ANOVA and Scheffé post-hoc tests. The polished surfaces were examined qualitatively by SEM. The results showed significant effects on surface roughness from the different composites (p = 0.011) and polishing systems (p < 0.001). After polishing, the Solitaire surfaces (R(a) = 0.72 microm) were smoother than Definite (R(a) = 0.87 microm) and SureFil (R(a) = 0.89 microm) and significantly smoother than Herculite (R(a) = 0.92 microm; p = 0.011). Three of the polishing methods (SuperBuff, Diafix-oral and Astropol) achieved lower R(a)-values than Sof-Lex discs. The polishing quality of the one-step systems SuperBuff and Diafix-oral was strongly affected by the initial finishing protocol.
Polishing mechanism of light-initiated dental composite: Geometric optics approach.
Chiang, Yu-Chih; Lai, Eddie Hsiang-Hua; Kunzelmann, Karl-Heinz
2016-12-01
For light-initiated dental hybrid composites, reinforcing particles are much stiffer than the matrix, which makes the surface rugged after inadequate polish and favors bacterial adhesion and biofilm redevelopment. The aim of the study was to investigate the polishing mechanism via the geometric optics approach. We defined the polishing abilities of six instruments using the obtained gloss values through the geometric optics approach (micro-Tri-gloss with 20°, 60°, and 85° measurement angles). The surface texture was validated using a field emission scanning electron microscope (FE-SEM). Based on the gloss values, we sorted polishing tools into three abrasive levels, and proposed polishing sequences to test the hypothesis that similar abrasive levels would leave equivalent gloss levels on dental composites. The three proposed, tested polishing sequences included: S1, Sof-Lex XT coarse disc, Sof-Lex XT fine disc, and OccluBrush; S2, Sof-Lex XT coarse disc, Prisma Gloss polishing paste, and OccluBrush; and S3, Sof-Lex XT coarse disc, Enhance finishing cups, and OccluBrush. S1 demonstrated significantly higher surface gloss than the other procedures (p < 0.05). The surface textures (FE-SEM micrographs) correlated well with the obtained gloss values. Nominally similar abrasive abilities did not result in equivalent polish levels, indicating that the polishing tools must be evaluated and cannot be judged based on their compositions or abrasive sizes. The geometric optic approach is an efficient and nondestructive method to characterize the polished surface of dental composites. Copyright © 2015. Published by Elsevier B.V.
Active Mirror Predictive and Requirements Verification Software (AMP-ReVS)
NASA Technical Reports Server (NTRS)
Basinger, Scott A.
2012-01-01
This software is designed to predict large active mirror performance at various stages in the fabrication lifecycle of the mirror. It was developed for 1-meter class powered mirrors for astronomical purposes, but is extensible to other geometries. The package accepts finite element model (FEM) inputs and laboratory measured data for large optical-quality mirrors with active figure control. It computes phenomenological contributions to the surface figure error using several built-in optimization techniques. These phenomena include stresses induced in the mirror by the manufacturing process and the support structure, the test procedure, high spatial frequency errors introduced by the polishing process, and other process-dependent deleterious effects due to light-weighting of the mirror. Then, depending on the maturity of the mirror, it either predicts the best surface figure error that the mirror will attain, or it verifies that the requirements for the error sources have been met once the best surface figure error has been measured. The unique feature of this software is that it ties together physical phenomenology with wavefront sensing and control techniques and various optimization methods including convex optimization, Kalman filtering, and quadratic programming to both generate predictive models and to do requirements verification. This software combines three distinct disciplines: wavefront control, predictive models based on FEM, and requirements verification using measured data in a robust, reusable code that is applicable to any large optics for ground and space telescopes. The software also includes state-of-the-art wavefront control algorithms that allow closed-loop performance to be computed. It allows for quantitative trade studies to be performed for optical systems engineering, including computing the best surface figure error under various testing and operating conditions. After the mirror manufacturing process and testing have been completed, the software package can be used to verify that the underlying requirements have been met.
Guo, Shaolong; Zhang, Feihu; Zhang, Yong; Luan, Dianrong
2014-01-01
Through the polishing experiments of potassium dihydrogen phosphate (KDP) crystals based on deliquescent action, the effect of several major factors, including crystal's initial surface state, polishing time, and revolution of polishing plate, on material removal was researched. Under certain experimental conditions, the rules of material removal were reached, and experimental results are discussed, which lays the foundation for popularization and application of polishing technology for KDP crystals based on deliquescent action.
Study of Mechano-Chemical Machining of Ceramics and the Effect on Thin Film Behavior.
1981-06-01
polished 7 dry on nylon using NaCI 3 Photomicrographs of the etched surfaces of MgO polished 8 .wet on glass using NaCl 4 Surface profile and Nomarski ...micrograph of a Si wafer 10 taken before mechano-chemical polishing 5 Surface profile and Nomarski micrograph of a Si wafer 11 taken after mechano... Nomarski micrographs of mechano-chemically-polished 21 sapphire and tape-cast alumina 14 Surface profiles of mechano-chemically-polished sapphire 22
Study on optical polishing experiment of zerodur mirror
NASA Astrophysics Data System (ADS)
Wang, Huijun; Li, Hang; Wang, Peng; Guo, Wen; Wang, Yonggang; Du, Yan; Dong, Huiwen
2014-08-01
A zerodur mirror whose aperture is 900mm is chosen to be the primary mirror of an optical system. The mirror is polished by rapid polishing and precision polishing methods relatively. The final surface figures of the mirror are as follows: the peak-to-valley value (P-V value) is 0.204λ (λ=632.8nm), and the root-mean-square value (RMS value) is 0.016λ, which meet the requirement of the optical system. The results show that the polishing process is feasible.
Surface polishing of niobium for superconducting radio frequency (SRF) cavity applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Liang
2014-08-01
Niobium cavities are important components in modern particle accelerators based on superconducting radio frequency (SRF) technology. The interior of SRF cavities are cleaned and polished in order to produce high accelerating field and low power dissipation on the cavity wall. Current polishing methods, buffered chemical polishing (BCP) and electro-polishing (EP), have their advantages and limitations. We seek to improve current methods and explore laser polishing (LP) as a greener alternative of chemical methods. The topography and removal rate of BCP at different conditions (duration, temperature, sample orientation, flow rate) was studied with optical microscopy, scanning electron microscopy (SEM), and electronmore » backscatter diffraction (EBSD). Differential etching on different crystal orientations is the main contributor to fine grain niobium BCP topography, with gas evolution playing a secondary role. The surface of single crystal and bi-crystal niobium is smooth even after heavy BCP. The topography of fine grain niobium depends on total removal. The removal rate increases with temperature and surface acid flow rate within the rage of 0~20 °C, with chemical reaction being the possible dominate rate control mechanism. Surface flow helps to regulate temperature and avoid gas accumulation on the surface. The effect of surface flow rate on niobium EP was studied with optical microscopy, atomic force microscopy (AFM), and power spectral density (PSD) analysis. Within the range of 0~3.7 cm/s, no significant difference was found on the removal rate and the macro roughness. Possible improvement on the micro roughness with increased surface flow rate was observed. The effect of fluence and pulse accumulation on niobium topography during LP was studied with optical microscopy, SEM, AFM, and PSD analysis. Polishing on micro scale was achieved within fluence range of 0.57~0.90 J/cm2, with pulse accumulation adjusted accordingly. Larger area treatment was proved possible by overlapping laser tracks at proper ratio. Comparison of topography and PSD indicates that LP smooths the surface in a way similar to EP. The optimized LP parameters were applied to different types of niobium surfaces representing different stages in cavity fabrication. LP reduces the sharpness on rough surfaces effectively, while doing no harm to smooth surfaces. Secondary ion mass spectrometer (SIMS) analysis showed that LP reduces the oxide layer slightly and no contamination occurred from LP. EBSD showed no significant change on crystal structure after LP.« less
Paradowska-Stankiewicz, Iwona; Korczyńska, Monika R; Cieślak, Katarzyna; Kowalczyk, Dorota; Szymański, Karol; Brydak, Lidia B
2018-01-01
Influenza vaccination is the best measure available to prevent seasonal influenza infection. The majority of studies on vaccine effectiveness in the 2015/16 season conducted in the European I-MOVE+ Project, show that a match between the circulating influenza strains in the general public and those included in the vaccine for the Northern Hemisphere was low to moderate. As part of I-MOVE+, Poland has implemented a case control negative study design and molecular biology methods, such as real time RT-PCR, to assess the vaccine match and effectiveness. The research described herein consisted of two major influenza vaccine effectiveness investigations conducted in Poland in the 2015/16 season. The general practice part of the study included 228 cases consisting of 159 type A, 65 type B, and 4 coinfections (types A + B), and 312 negative control cases. The hospital study part included 26 cases consisting of 21 type A, 2 type B, and 3 coinfections, and 13 negative control cases. The data were collected from patients of all ages recruited by 46 volunteering doctors in 15 Poland's provinces and three hospitals, respectively. In both study parts, only were seven patients and 12 control subjects vaccinated. Low vaccine coverage, a major limitation of the Polish study, makes the calculation of vaccine effectiveness for the Polish population hardly applicable statistically. Despite the crudeness of data, they were included into the common European analysis. The overall vaccine effectiveness amounted to 21.0% (95% CI: 74-122). It was somehow better for type B virus: 53.9% (95% CI: 47-87) and type A virus: 23.6% (95% CI: 83-185). A larger sample size is needed to achieve a desired interpretation of results on influenza vaccine effectiveness in Poland.
NASA Astrophysics Data System (ADS)
Wang, W. J.; Yung, K. C.; Choy, H. S.; Xiao, T. Y.; Cai, Z. X.
2018-06-01
Laser polishing of 3D printed metal components has drawn great interest in view of its potential applications in the dental implant industries. In this study, corrosion resistance, surface composition and crystalline structure of CoCr alloys were investigated. The corrosion resistance, micromorphology, composition, phase transformations and crystalline structures of samples were characterized using an electrochemical analyzer, scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and transmission electron microscope (TEM), respectively. The results indicate that high laser powers and low object distances within a certain range can facilitate the formation of complex oxide films, which exhibits high corrosion resistance. Further, object distances have a significant influence on cooling rates during the solidification of the melt pool in laser polishing, and fast cooling generates vast amounts of vacancies and defects, which result in the crystalline phase transformation from γ to ε. Consequently, the formed oxides play an important role in corrosion resistance on the outer layer, and inner layer with γ phase also helps keep the CoCr alloys in a stable structure with high resistant to corrosion. The two process parameters in laser polishing, laser power and object distances, are demonstrated as being important for controlling the surface microstructures and corrosion resistance of the additive manufactured CoCr alloy components.
McLucas, E; Moran, M T; Rochev, Y; Carroll, W M; Smith, T J
2006-01-01
The surface properties of vascular devices dictate the initial postimplantation reactions that occur and thus the efficacy of the implantation procedure. Over the last number of years, a number of different stent designs have emerged and stents are generally polished to a mirror finish during the manufacturing procedure. This study sought to investigate the effect of stainless steel surface roughness on endothelial cell gene expression using an appropriate cell culture in vitro assay system. Stainless steel discs were roughened by shot blasting or polished by mechanical polishing. The surface roughness of the treated and untreated discs was determined by atomic force microscopy (AFM). Cells were seeded on collagen type 1 gels and left to attach for 24 h. Stainless steel discs of varying roughness were then placed in contact with the cells and incubated for 24 h. RNA extractions and quantitative real-time reverse transcriptase-polymerase chain reaction (RT-PCR) was then performed to determine the expression levels of candidate genes in the treated cells compared to suitable control cells. E-selectin and vascular cellular adhesion molecule (VCAM-1) were found to be significantly up-regulated in cells incubated with polished and roughened samples, indicating endothelial cell activation and inflammation. This study indicates that the surface roughness of stainless steel is an important surface property in the development of vascular stents.
The Effect of Prophylactic Polishing Pastes on Surface Roughness of Indirect Restorative Materials
Can Say, Esra; Yurdagüven, Haktan; Malkondu, Özlem; Ünlü, Nimet; Soyman, Mübin; Kazazoğlu, Ender
2014-01-01
The purpose of this study was to evaluate the influence of prophylactic polishing pastes (PPP; Detartrine (DT), Topex (TP)) on surface roughness (R a) of indirect composites (IRC; Tescera (TES), Gradia (GRD), and Estenia C&B (EST)), a glass ceramic (Empress 2 layering (E2)), and a leucite reinforced glass ceramic (Empress Esthetic (EE)) with two different (glazed (G); polished (P)) surface preparations. A total of 90 IRC and 120 ceramic discs, 8 mm in diameter and 2 mm thick, were prepared. E2 and EE specimens were randomly divided into two groups (n = 30). One group was glazed (GE2; GEE), while the other group was polished (PE2; PEE) the same as the IRCs. The specimens in each group were subsequently divided into three subgroups: control (C), DT, and TP. R a (μm) was evaluated with a profilometer. Data were analyzed by Kruskal Wallis, followed by the Dunn's multiple comparison tests (P < 0.05). DT and TP resulted in significant surface roughening for TES, GRD, and EST, while no significant differences were detected between DT and TP (P > 0.05). PE2 and PEE were not affected by DT or TP (P > 0.05), while GE2 and GEE exhibited significant roughening after TP (P < 0.05). Surface roughness of IRCs and glazed ceramics can be affected by PPP applications. PMID:24729757
Polish system of education in maritime health care and medical assistance for seafarers.
Chodnik, Tomasz; Jeżewska, Maria; Jaremin, Bogdan; Kotłowski, Andrzej; Leszczyńska, Irena; Grubman-Nowak, Marta
2013-01-01
The Polish public awareness of the crucial importance of the own maritime economy to the very existenceof the national state has its historical reasons. The Polish maritime involvement has seen several dramaticcrises, but the Polish nationals have become an established group in the global marine trade workforceand are entitled to the proper health care. In this paper the main maritime health issues are mentioned.To meet the issues, also the national education system provides the opportunities for both seafarers andmedical professionals. The Polish doctors can specialise in the maritime medicine. In many cases the generalmedicine students formations include these topics as well. The psychological aspects are also takeninto account, both of the education of the seafarers and the organisational structure of the Polish healthcare system. Some recent aspects of the Polish participation in the international cooperation in the fieldof the medical support of the maritime economy are also described.
NASA Astrophysics Data System (ADS)
Suzuki, Hirofumi; Kawamori, Ryota; Yamamoto, Yuji; Miyabara, Mitsuru; Okino, Tadashi; Hijikata, Yoshio; Moriwaki, Toshimichi
2005-05-01
Micro aspherical glass lenses are required for electronic devices, optical devices and advanced optical fiber transmission equipments. The glass lenses are manufactured by glass molding method by using micro ceramics dies such as tungsten carbide or silicon carbide (1). Therefore molding dies are most important and they were ground by ultra-precision grinding method with diamond wheel. Recently, the wavelength of used laser is becoming shorter and then the accuracies of the micro molding die are required to be much more precise (2). In this paper, ultrasonic assisted polishing methods/systems were developed in order to finish micro aspherical dies that were ground with micro diamond wheel. In the polishing experiments, the molding die of tungsten carbide was polished with diamond abrasives to test the basic polishing characteristics and the aspheric die was polished with proposed ultrasonic assisted polishing method.
Electrochemical Polishing Applications and EIS of a Novel Choline Chloride-Based Ionic Liquid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.
2013-06-01
Minimal surface roughness is a critical feature for high-field superconducting radio frequency (SRF) cavities used to engineer particle accelerators. Current methods for polishing Niobium cavities typically utilize solutions containing a mixture of concentrated sulfuric and hydrofluoric acid. Polishing processes such as these are effective, yet there are many hazards and costs associated with the use (and safe disposal) of the concentrated acid solutions. An alternative method for electrochemical polishing of the cavities was explored using a novel ionic liquid solution containing choline chloride. Potentiostatic electrochemical impedance spectroscopy (EIS) was used to analyze the ionic polishing solution. Final surface roughness ofmore » the Nb was found to be comparable to that of the acid-polishing method, as assessed by atomic force microscopy (AFM). This indicates that ionic liquid-based electrochemical polishing of Nb is a viable replacement for acid-based methods for preparation of SRF cavities.« less
Internet Use of Polish by Polish Melburnians: Implications for Maintenance and Teaching
ERIC Educational Resources Information Center
Fitzgerald, Michael; Debski, Robert
2006-01-01
The Internet has become an important communication medium and it is having a significant impact on language use. The present study takes a "snapshot" of how the Polish language is currently used with modern communications technologies by Polish-Australians living in Melbourne. Through a questionnaire, it surveys which communications…
The Relationship between Polish and Other Slavic Languages.
ERIC Educational Resources Information Center
Birkenmayer, Sigmund S.
This paper discusses the relationship of Polish to the other languages considered to be within the Slavic group. The comparison is mainly phonological and considers the Proto-Slavic features still preserved in Polish as well as the distinctive features of Polish which have developed from Proto-Slavic. The development of vowels and consonants is…
Polish Migrant Parents of Secondary School Boys in the United Kingdom
ERIC Educational Resources Information Center
Tkacz, Daria; McGhee, Derek
2016-01-01
This article focuses on the parents of secondary school Polish boys and their capacity to realise their educational and professional aspirations for their children. Our primary finding is that although many Polish parents face considerable challenges in manoeuvring through the educational system, some Polish parents display a level of agency…
Subsurface Damage in Polishing Process of Silicon Carbide Ceramic
Gu, Yan; Zhu, Wenhui; Lin, Jieqiong; Lu, Mingming; Kang, Mingshuo
2018-01-01
Subsurface damage (SSD) in the polishing process of silicon carbide (SiC) ceramic presents one of the most significant challenges for practical applications. In this study, the theoretical models of SSD depth are established on the basis of the material removal mechanism and indentation fracture mechanics in the SiC ceramic polishing process. In addition, the three-dimensional (3D) models of single grit polishing are also developed by using the finite element simulation; thereby, the dynamic effects of different process parameters on SSD depth are analyzed. The results demonstrate that the material removal was mainly in brittle mode when the cutting depth was larger than the critical depth of the brittle material. The SSD depth increased as the polishing depth and abrasive grain size increased, and decreased with respect to the increase in polishing speed. The experimental results suggested a good agreement with the theoretical simulation results in terms of SSD depth as a function of polishing depth, spindle speed, and abrasive grain size. This study provides a mechanistic insight into the dependence of SSD on key operational parameters in the polishing process of SiC ceramic. PMID:29584694
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; ...
2017-09-11
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less
NASA Astrophysics Data System (ADS)
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.
2017-09-01
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.
The influence of the level formants on the perception of synthetic vowel sounds
NASA Astrophysics Data System (ADS)
Kubzdela, Henryk; Owsianny, Mariuz
A computer model of a generator of periodic complex sounds simulating consonants was developed. The system makes possible independent regulation of the level of each of the formants and instant generation of the sound. A trapezoid approximates the curve of the spectrum within the range of the formant. In using this model, each person in a group of six listeners experimentally selected synthesis parameters for six sounds that to him seemed optimal approximations of Polish consonants. From these, another six sounds were selected that were identified by a majority of the six persons and several additional listeners as being best qualified to serve as prototypes of Polish consonants. These prototypes were then used to randomly create sounds with various combinations at the level of the second and third formant and these were presented to seven listeners for identification. The results of the identifications are presented in table form in three variants and are described from the point of view of the requirements of automatic recognition of consonants in continuous speech.
Gloss and Stain Resistance of Ceramic-Polymer CAD/CAM Restorative Blocks.
Lawson, Nathaniel C; Burgess, John O
2016-03-01
To evaluate the gloss and stain resistance of several new ceramic-polymer CAD/CAM blocks Specimens (4 mm) were sectioned from: Enamic (polymer-infused ceramic), LAVA Ultimate (nano-ceramic reinforced polymer), e.max (lithium disilicate), Paradigm C (porcelain), and Paradigm MZ100 (composite). Specimens were wet polished on a polishing wheel to either 320 grit silicon paper (un-polished, N = 8) or 2000 grit silicon carbide papers followed by a 0.05 μm alumina slurry (polished, N = 8). Initial gloss and color (L*a*b*) values were measured. Specimens were stored in a staining solution at 37°C in darkness for 12 days (simulating 1 year). After storage, L*a*b* values re-measured. Change in color was reported as ΔE00 based on the CIEDE2000 formula. Gloss and ΔE00 were analyzed by two-way analysis of variance (ANOVA) (alpha = .05). Separate one-way ANOVA and Tukey post-hoc analyses were performed for both polish conditions and all materials. Two-way ANOVA showed that factors material, polish and their interaction were significant for both gloss and ΔE00 (p < .01). Post-hoc analysis reveals that polished specimens had significantly less color change than un-polished specimens for Paradigm C and LAVA Ultimate. E.max had significantly higher gloss and less color change than all other materials. The composition and polish of CAD/CAM materials affects gloss and stain resistance. Ceramic-polymer hybrid materials can achieve the high gloss required for esthetic restorations. These materials should be polished in order to minimize staining. If polished, all of the tested materials exhibited clinically acceptable color changes at 1 year of simulated staining. (J Esthet Restor Dent 28:S40-S45, 2016). © 2015 Wiley Periodicals, Inc.
Yoon, Hyung-In; Noh, Hyo-Mi; Park, Eun-Jin
2017-06-01
This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P <.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P <.05). Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.
Noh, Hyo-Mi
2017-01-01
PURPOSE This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P<.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P<.05). CONCLUSION Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate. PMID:28680550
Ferraris, Federico; Conti, Alessandro
2014-01-01
The following study asks three principle questions relative to composite finishing and composite polishing: 1) Will the superficial roughness of different restoration surfaces have different values, utilizing the same polishing system (multistep), after finishing with the tungsten carbide or diamond bur? 2) Under the same conditions of finishing and polishing sequences, will the composite surfaces (C), the composite-enamel (CE) and composite-dentin (CD) interfaces show different roughness values? 3) Will the surface roughness of composites of different translucency in the various phases of finishing and polishing, and on different interfaces, have different results? The null hypothesis is represented by the fact that there are no significant differences on roughness of composite restorations when polishing, after finishing with tungsten carbide or diamond burs. Furthermore, the null hypothesis is that there are no significant differences on roughness between polishing on composite surface, composite-enamel and composite-dentin interfaces, and finally there are no differences on roughness after finishing and polishing of two composite with different translucency. For the study, 56 class V cavities were prepared on extracted teeth. Restorations were done in nanofilled composite Filtek XTE (3M Espe) in a standard fashion, and then finished and polished. The 28 buccal cavities were restored on the surface with composite enamel and the 28 palatals with composite body. Finishing was done with fine toothing burs in tungsten carbide (16 blades) or fine grit diamond burs (46 μm), and made by the same manufacturer (Komet). The second phase of finishing was done with burs (with the same form as already mentioned) ultrafine toothing tungsten carbide (30 blades) or with extra and ultrafine grit diamond (25 and 8 μm). The polishing phase for both of the earlier sequences was done with the application of three rubber tips with decreasing abrasiveness and an application with a self-polishing brush. All measurements were taken from surfaces C, and interfaces CE and CD. Statistical analyses were carried out with c2 test (a = 0.05). 1) There were no relevant differences of surface roughness on the different surfaces if the polishing was done after finishing with tungsten carbide or diamond burs. 2) Keeping the same sequence of finishing and polishing, a difference was noticed between C, CE and CD, where the latter showed greater roughness. 3) Analyzing the data in all the phases of finishing and polishing on every interface, it can be concluded that the composite enamel and the composite body did not show different levels of superficial roughness. The clinical relevance could be resumed as follows: no difference after polishing, which is preceded by tungsten carbide or diamond finishing burs. The less favorable interface to be polished is CD, compared to CE and C. Considering two composites with different translucency, no difference on roughness after finishing and polishing were detected.
Ageing and Learning Experiences: The Perspective of a Polish Senior Immigrant in Sweden
ERIC Educational Resources Information Center
Rawinski, Malgorzata Malec
2017-01-01
The general aim of this paper is to present some insights into Polish senior immigrants in Sweden. In particular, it seeks to identify and illustrate the important contribution of previous generations of Polish senior immigrants in building on the diverse culture, traditions and values of the Polish community (Polonia) in Sweden. The paper…
Higher Magnification Imaging of the Polished Aluminum Collector Returned from the Genesis Mission
NASA Technical Reports Server (NTRS)
Rodriquez, Melissa C.; Burkett, P. J.; Allton, J. H.
2011-01-01
The polished aluminum collector (previously referred to as the polished aluminum kidney) was intended for noble gas analysis for the Gene-sis mission. The aluminum collector, fabricated from alloy 6061T, was polished for flight with alumina, then diamond paste. Final cleaning was performed by soak-ing and rinsing with hexane, then isopropanol, and last-ly megasonically energized ultrapure water prior to installation. It was mounted inside the collector canister on the thermal shield at JSC in 2000. The polished aluminum collector was not surveyed microscopically prior to flight.
Method of fabricating a whispering gallery mode resonator
NASA Technical Reports Server (NTRS)
Savchenkov, Anatoliy A. (Inventor); Matkso, Andrey B. (Inventor); Iltchenko, Vladimir S. (Inventor); Maleki, Lute (Inventor)
2011-01-01
A method of fabricating a whispering gallery mode resonator (WGMR) is provided. The WGMR can be fabricated from a particular material, annealed, and then polished. The WGMR can be repeatedly annealed and then polished. The repeated polishing of the WGMR can be carried out using an abrasive slurry. The abrasive slurry can have a predetermined, constant grain size. Each subsequent polishing of the WGMR can use an abrasive slurry having a grain size that is smaller than the grain size of the abrasive slurry of the previous polishing iteration.
Paul-Samojedny, Monika; Kowalczyk, Malgorzata; Suchanek, Renata; Owczarek, Aleksander; Fila-Danilow, Anna; Szczygiel, Aleksandra; Kowalski, Jan
2010-09-01
Schizophrenia is a multifactorial disease with changes in immunological system. Such changes are the result of cytokine-level disturbances connected with cytokine gene polymorphisms. However, research about cytokine gene polymorphisms in schizophrenia has been surprisingly limited and ambiguous. The aim of the study was to identify whether polymorphisms of interleukin (IL)-6 and IL-10 are risk factors for the development of paranoid schizophrenia in case-control study. IL-6 (-174G/C; rs 1800795) and IL-10 (-1082G/A; rs 1800896) promoter polymorphisms in patients with paranoid schizophrenia and healthy individuals were genotyped using polymerase chain reaction-restriction fragment length polymorphism method. Differences in IL-6 and IL-10 promoter haplotypes may play an important role in determining the transcription level for IL-6 and IL-10 genes in schizophrenic patients. The presence of allele C at position -174 of IL-6 promoter sequence may correlate with increasing risk of paranoid schizophrenia in the Polish population, but research on a broadened group of people is needed. The presence of allele G at position -1082 of IL-10 promoter sequence correlates with increasing risk of paranoid schizophrenia in the Polish population. The coexistence of genotype GG at position -1082 of IL-10 promoter sequence and genotype GC at position -174 of IL-6 promoter sequence correlates with increasing risk of paranoid schizophrenia in the Polish population.
The Discovery Channel Telescope: Construction and Design Progress, January 2007
NASA Astrophysics Data System (ADS)
Bida, Thomas A.; Millis, R. L.; Smith, B. W.; Dunham, E. W.; Marshall, H.
2006-12-01
The Discovery Channel Telescope (DCT) is a 4.2m telescope under construction in northern Arizona. The DCT is located at a new site near Happy Jack at 2361m elevation, which was selected following a lengthy site testing campaign that demonstrated DIMM-characterized median ground-level seeing of 0.84-arcsec FWHM. The DCT science mission includes targeted studies of astrophysical and solar system objects utilizing RC and Nasmyth-mounted imaging and spectroscopic instrumentation, and wide-field surveys of KBO’s, NEA’s, and astrophysical objects with a 2-degree FOV prime focus camera. The DCT facility enclosure and control buildings will be completed soon, including the telescope mount and dome supports, major machinery infrastructure, the instrument laboratory, control and computer rooms, and the auxiliary building for the mirror coating plant. Meanwhile, the effort for final figuring and polishing of the 4.3m ULE meniscus primary mirror blank began in August 2006 at the University of Arizona College of Optical Sciences. The primary mirror and its design support, and the integrated telescope mount model, were finite-element analyzed to optimize the design of the mirror and top-end support configurations. The primary mirror axial and tangential actuators will be fabricated in early 2007 and utilized in the final figure and polish cycle. The prime focus camera design has been refined to achieve atmospheric dispersion-compensated 0.25-arcsec images at 1-degree field radius, from B to I-band, at reduced cost through simplification of glasses to standard types and utilization of spheres on all but two lens surfaces. The Discovery Channel Telescope is a project of the Lowell Observatory with major financial support from Discovery Communications, Inc. (DCI). DCI plans ongoing television programming featuring the construction of the telescope and the research ultimately conducted with the DCT. Lowell Observatory and Discovery Communications are actively seeking additional partners in the project; interested parties should contact R. L. Millis, Director.
Effect of slurry composition on the chemical mechanical polishing of thin diamond films
Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.
2017-01-01
Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films’ various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones. PMID:29057022
Effect of slurry composition on the chemical mechanical polishing of thin diamond films
NASA Astrophysics Data System (ADS)
Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.
2017-12-01
Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films' various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones.
Cross-cultural sex differences in situational triggers of aggressive responses.
Zajenkowska, Anna; Mylonas, Kostas; Lawrence, Claire; Konopka, Karolina; Rajchert, Joanna
2014-10-01
This paper examines male and female individual differences in situational triggers of aggressive responses (STAR) in three countries as well as cross-cultural sex differences in trait aggression (aggression questionnaire, AQ). Convenience sampling was employed (university students) for the descriptive correlational study (Poland N = 300, 63% female, mean age 21.86, SD = 2.12; UK N = 196, 60% female, mean age 20.48, SD = 3.79; Greece N = 299, 57% female, mean age 20.71, SD = 4.42). The results showed that the STAR scale is an equivalent construct across all three countries. Overall, females were more sensitive to both provocation (SP) and frustration (SF) than males. When controlling for trait aggression, Polish and Greek females scored similarly in SP and higher than UK females. No sex differences in SP or SF were found in the UK sample. Additionally, Polish participants scored the highest in SP. Furthermore, when trait aggression was removed, the Greek participants were most sensitive to frustration, whereas Polish and English participants' SF did not differ. We discuss the results with regard to intercultural differences between investigated countries. © 2014 International Union of Psychological Science.
Pulsed laser deposited ZnO film on side-polished fiber as a gas sensing element.
Dikovska, Anna Og; Atanasov, Petar A; Stoyanchov, Toshko R; Andreev, Andrey T; Karakoleva, Elka I; Zafirova, Blagovesta S
2007-05-01
A simple sensor element consisting of a side-polished single-mode fiber and a planar metal oxide waveguide is described. The thin ZnO planar waveguide was produced on the polished fiber surface by pulsed laser deposition at optimized processing parameters. A measurement scheme for in situ control of the film thickness during the deposition process was developed and used. X-ray diffraction measurements and scanning electron microscopy were used to characterize the structure and the surface morphology of the planar waveguide, respectively. The numerical evaluation of the sensor sensitivity predicts the possibility to detect refractive index changes of less than 10(-4). Furthermore, preliminary gas sensor tests were performed by using a mixture of 1.5% butane diluted in N(2) and pure butane. A shift of the spectral position of the resonance points was observed from 3 to 5 s after gas exposure, which corresponds to refractive index changes of 3 x 10(-5) and 1.2 x 10(-3) for 1.5% butane and for pure butane, respectively.
A new photocatalytic reactor for trace contaminant control: a water polishing system.
Gonzalez-Martin, A; Kim, J; Van Hyfte, J; Rutherford, L A; Andrews, C
2001-01-01
In spacecraft water recovery systems there is a need to develop a postprocessor water polishing system to remove organic impurities to levels below 250 micrograms/L (ppb) with a minimum use of expendables. This article addresses the development of a photocatalytic process as a postprocessor water polishing system that is microgravity compatible, operates at room temperature, and requires only a minimal use of both oxygen gas (or air) and electrical power for low energy UV-A (315-400 nm) lamps. In the photocatalytic process, organic contaminants are degraded to benign end products on semiconductor surfaces, usually TiO2. Some challenging issues related to the use of TiO2 for the degradation of organic contaminants have been addressed. These include: i) efficient and stable catalytic material; ii) immobilization of the catalyst to produce a high surface area material that can be used in packed-bed reactors, iii) effective light penetration, iv) effective, microgravity-compatible, oxidant delivery; v) reduced pressure drop, and vi) minimum retention time. The research and development performed on this photocatalytic process is presented in detail. Grant numbers: NAS9-97182.
Study of Profile Changes during Mechanical Polishing using Relocation Profilometry
NASA Astrophysics Data System (ADS)
Kumaran, S. Chidambara; Shunmugam, M. S.
2017-10-01
Mechanical polishing is a finishing process practiced conventionally to enhance quality of surface. Surface finish is improved by mechanical cutting action of abrasive particles on work surface. Polishing is complex in nature and research efforts have been focused on understanding the polishing mechanism. Study of changes in profile is a useful method of understanding behavior of the polishing process. Such a study requires tracing same profile at regular process intervals, which is a tedious job. An innovative relocation technique is followed in the present work to study profile changes during mechanical polishing of austenitic stainless steel specimen. Using special locating fixture, micro-indentation mark and cross-correlation technique, the same profile is traced at certain process intervals. Comparison of different parameters of profiles shows the manner in which metal removal takes place in the polishing process. Mass removal during process estimated by the same relocation technique is checked with that obtained using weight measurement. The proposed approach can be extended to other micro/nano finishing processes and favorable process conditions can be identified.
Hämmerle, C H; Brägger, U; Bürgin, W; Lang, N P
1996-06-01
In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implant the apical border of the polished surface was placed approximately 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and "attachment" levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p < 0.05) was found between test and control implants with the test implants being placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p < 0.05; control 0.58 mm, p < 0.05). However, only the test implants significantly lost clinical bone height from 4-12 months (test 1.04 mm, p < 0.05; control 0.45 mm, p = 0.08). Overall, the test implants lost 2.26 mm and the control implants 1.02 mm of bone height during the first year of service. On the average, the test implants demonstrated a bone level of 0.38 mm lower than the controls at 12 months. Except for the modified gingival index at 4 months (mean difference 0.21, SD 0.19, p < 0.05), no clinical parameters yielded significant differences between test and control implants at any time. It is concluded that in addition to the crestal bone resorption occurring at implants placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. From a biological point of view, the placement of the border between the rough and the smooth surfaces into a subcrestal location should not be recommended.
NASA Astrophysics Data System (ADS)
Rastegar, Vahid
Nanoscale finishing and planarization are integral process steps in multilevel metallization designs for integrated circuit (IC) manufacturing since it is necessary to ensure local and global surface planarization at each metal layer before depositing the next layer. Chemical mechanical planarization (CMP) has been widely recognized as the most promising technology to eliminate topographic variation and has allowed the construction of multilevel interconnection structures with a more regularly stacked sequence, resulting in better device performance [1]. Understanding fundamental of the CMP mechanisms can offer guidance to the control and optimization of the polishing processes. CMP kinematics based on slurry distribution and particle trajectories have a significant impact on MRR profiles. In this work a mathematical model to describe particle trajectories during chemical mechanical polishing was developed and extended to account for the effect of larger particles, particle location changes due to slurry dispensing and in-situ conditioning. Material removal rate (MRR) and within wafer non-uniformity (WIWNU) were determined based on the calculated particle trajectory densities. Rotary dynamics and reciprocating motion were optimized to obtain best MRR uniformity. Edge-fast MRR profile was discussed based on mechanical aspect of CMP. Using the model, we also investigated the effect of variable rotational speeds of wafer and pad, and of large particles on WIWNU and scratch growth. It was shown that the presence of even a small portion of large particles can deteriorate the WIWNU significantly and also lead to more scratches. Furthermore, it was shown that the in-situ conditioning improves the uniformity of the polished wafers. Furthermore, a combined experimental and computational study of fibrous filters for removal of larger abrasive particles from aqueous dispersions, essential to minimize defects during chemical mechanical polishing, was performed. Dilute aqueous suspensions of colloidal ceria particles, of known size distribution, were filtered at different flow rates and the filter efficiencies were measured for different particle sizes and pH, then converted to single fiber efficiencies. The particle size distributions were also measured for the influent and effluent streams. In a series of numerical simulations, the Navier-Stokes equation was solved for a single fiber using the ANSYS-FLUENT computational fluid dynamics commercial package. For dilute suspensions, the motion of the dispersed particles in the size range of 35-600 nm and zeta potential range of -50 to 50 mV was tracked in the Lagrangian reference frame including the effects of hydrodynamic drag, lift, gravity, hydrodynamic retardation, Brownian, van der Waals and electric double layer forces. The electric double layer and van der Waals forces were incorporated in the calculations by developing a user defined function. Particular attention was given to the effects of Brownian excitations, as well as the electric double layer and van der Waals forces that have been neglected in many of the previous models on the overall fiber collection efficiency for different particle sizes and charges. Moreover, the effect of flow velocity on the fiber capture efficiency and residence time was investigated. The effect of velocity on minimum collection efficiency and most penetrating particle size was investigated. It was also shown that the CFD results are in a good agreement with the experimental results.
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
Enclosed Cutting-And-Polishing Apparatus
NASA Technical Reports Server (NTRS)
Rossier, R. N.; Bicknell, B.
1989-01-01
Proposed apparatus cuts and polishes specimens while preventing contamination of outside environment or of subsequent specimens processed in it. Designed for use in zero gravity but also includes features useful in cutting and polishing of toxic or otherwise hazardous materials on Earth. Includes remote manipulator for handling specimens, cutting and polishing wire, inlets for gas and liquid, and outlets for waste liquid and gas. Replaceable plastic liner surrounds working space.
[Polish historical collection at the University of Edinburgh].
Tomaszewski, W
1995-01-01
The Polish School of Medicine, a joint Scottish-Polish academic enterprise, established in 1941 at the University of Edinburgh for soldiers-students in the Polish Forces, ceased its activity in 1949, four years after the end of the war. Owing to the stalinist terror in occupied Poland most of the 227 graduates remained in the West. There was a deep feeling of gratitude towards the University on the part of the graduates of the Polish School. The 25th anniversary of the School in 1966 was an opportunity to convoke in Edinburgh a world reunion of the graduates. At the academic ceremony two gold medals were presented to the University. The warm reception extended by the University, prompted the resolution to hold quinquennial world reunions in Edinburgh. Since then world reunions were held in Edinburgh every 5 years with meetings with the University authorities and presentation of gifts. By 1980 the number of gifts accumulated to such extent that the seminar room in the Erskine Medical Library was selected for the permanent display of the gifts; this served to intensify the collection of exhibits. Gifts were chosen to remind of certain events in the Polish history of medicine, especially items reflecting Polish links with Scotland. The highest achievement in the Scottish-Polish links, was of course the creation of the Polish School of Medicine. The official opening of the Historical Collection took place in June 1986 on the occasion of a world reunion on the 45th anniversary of the School. It was marked by the unveiling of a memorial plaque. On this ocasion another venture was also initiated: the opening of the Polish School of Medicine Memorial Fund at the University of Edinburgh. It was funded by the graduates to provide scholarship for young doctors from Poland. Another venture was the creation of the "Professor Antoni Jurasz lectureship" for Edinburgh professors to lecture in Medical Academies in Poland. The Historical Collection of the Polish School of Medicine at the University of Edinburgh is a permanent memorial to the magnanimity of the University left by the graduates. It is at the same time a windowshow of a 300 years old Scottish-Polish history of medicine.
Akar, Gülcan Coşkun; Pekkan, Gürel; Çal, Ebru; Eskitaşçıoğlu, Gürcan; Özcan, Mutlu
2014-08-01
Surface-finishing protocols have a mechanical impact on ceramic surfaces that could eventually affect surface topography and light scattering. An optimum protocol is needed to avoid damaging the optical properties of ceramics. The purpose of this study was to determine the effects of different surface-finishing protocols on the surface roughness, color change, and translucency of ceramic and metal ceramic restorations. Standardized disk-shaped specimens (1.5 × 10 mm, n=128) were fabricated from 3 different ceramic core materials (aluminum oxide [Al2O3]-AL, zirconium oxide [ZrO2]-ZR, lithium disilicate [Li2Si2O5]-LIT), veneered (V) with dentin ceramics (n=32 per group), and placed in the following groups: ALV, ZRV, and LITV. The metal ceramic group acted as the control (n=32). Four different surface-finishing methods were tested. Airborne-particle abrasion with 50 μm Al2O3, polishing with adjustment kit, polishing with adjustment kit plus diamond polishing paste, and autoglazing (n=8 subgroup) were applied on the veneering ceramics. The specimens were analyzed with a profilometer for surface roughness, and color change and translucency were measured with a clinical spectrophotometer. Statistical analyses were performed with 1-way ANOVA and the Tukey honest significant difference tests (α=.05). Specimens treated with the airborne particle abrasion method showed significantly higher mean profilometer for surface roughness values in all groups (P<.05). The polishing with adjustment kit and autoglazing methods revealed statistically similar surface roughness values in all groups (P>.05). With the diamond polishing paste method, lower surface roughness values were achieved in the ZRV and metal ceramic groups acted as the control groups. Different surface-finishing methods affected the color change of the ceramic systems, except for ZRV. Surface-finishing protocols significantly affected the translucency values of the ALV, LITV, and metal ceramic groups (P<.05). No single surface-finishing protocol can be recommended to obtain the smoothest surface and the least color change without affecting translucency for the ceramics tested. The airborne-particle abrasion protocol created rougher surfaces and decreased translucency, and color change in zirconia was not affected by the finishing protocols. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yashchuk, Valeriy V.; Centers, Gary; Tyurin, Yuri N.; Tyurina, Anastasia
2016-09-01
Recently, an original method for the statistical modeling of surface topography of state-of-the-art mirrors for usage in xray optical systems at light source facilities and for astronomical telescopes [Opt. Eng. 51(4), 046501, 2012; ibid. 53(8), 084102 (2014); and ibid. 55(7), 074106 (2016)] has been developed. In modeling, the mirror surface topography is considered to be a result of a stationary uniform stochastic polishing process and the best fit time-invariant linear filter (TILF) that optimally parameterizes, with limited number of parameters, the polishing process is determined. The TILF model allows the surface slope profile of an optic with a newly desired specification to be reliably forecast before fabrication. With the forecast data, representative numerical evaluations of expected performance of the prospective mirrors in optical systems under development become possible [Opt. Eng., 54(2), 025108 (2015)]. Here, we suggest and demonstrate an analytical approach for accounting the imperfections of the used metrology instruments, which are described by the instrumental point spread function, in the TILF modeling. The efficacy of the approach is demonstrated with numerical simulations for correction of measurements performed with an autocollimator based surface slope profiler. Besides solving this major metrological problem, the results of the present work open an avenue for developing analytical and computational tools for stitching data in the statistical domain, obtained using multiple metrology instruments measuring significantly different bandwidths of spatial wavelengths.
Production of primary mirror segments for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Allen, R. G.; Burge, J. H.; Davis, J. M.; Davison, W. B.; Johns, M.; Kim, D. W.; Kingsley, J. S.; Law, K.; Lutz, R. D.; Strittmatter, P. A.; Su, P.; Tuell, M. T.; West, S. C.; Zhou, P.
2014-07-01
Segment production for the Giant Magellan Telescope is well underway, with the off-axis Segment 1 completed, off-axis Segments 2 and 3 already cast, and mold construction in progress for the casting of Segment 4, the center segment. All equipment and techniques required for segment fabrication and testing have been demonstrated in the manufacture of Segment 1. The equipment includes a 28 m test tower that incorporates four independent measurements of the segment's figure and geometry. The interferometric test uses a large asymmetric null corrector with three elements including a 3.75 m spherical mirror and a computer-generated hologram. For independent verification of the large-scale segment shape, we use a scanning pentaprism test that exploits the natural geometry of the telescope to focus collimated light to a point. The Software Configurable Optical Test System, loosely based on the Hartmann test, measures slope errors to submicroradian accuracy at high resolution over the full aperture. An enhanced laser tracker system guides the figuring through grinding and initial polishing. All measurements agree within the expected uncertainties, including three independent measurements of radius of curvature that agree within 0.3 mm. Segment 1 was polished using a 1.2 m stressed lap for smoothing and large-scale figuring, and a set of smaller passive rigid-conformal laps on an orbital polisher for deterministic small-scale figuring. For the remaining segments, the Mirror Lab is building a smaller, orbital stressed lap to combine the smoothing capability with deterministic figuring.
Paravina, Rade D; Roeder, Leslie; Lu, Huan; Vogel, Karin; Powers, John M
2004-08-01
To evaluate the effects of different finishing and polishing procedures on surface roughness, gloss and color of five resin composites: two experimental microhybrid composites - FZ-Dentin (FZD) and FZ-Enamel (FZE), one commercial microhybrid composite - Esthet-X (EX), and two microfilled composites - Heliomolar (HM) and Renamel Microfill (RM). Surface roughness, gloss and color of the disc-shaped specimens (10 mm in diameter and 2-mm thick) were measured as Mylar (baseline), 16-fluted carbide bur and polishing were completed. Sixteen specimens of each composite were randomized to four groups of four. After finishing with a 16-fluted finishing bur, each group was polished by a different system: 1. Astropol (A), 2. Sof-lex disc (S), 3. Po-Go (P), 4. Enhance (E). Average surface roughness (Ra) was measured with a profilometer. Gloss measurements were performed using small-area glossmeter, while color coordinate values were recorded using a spectrophotometer. A deltaE*ab< or =1 was considered to be the limit of perceptibility. The order of surface roughness ranked according to polishing system (for all five composites together) was: P < S < E < A. The order of surface roughness ranked according to composites was: RM < FZD < FZ < HM < EX. The order of gloss ranked according to polishing system (for all five composites together) was: P > E > A > S. The order of gloss values for the polished composites (for each of four polishing systems) was: RM > FZD > FZE > HM > EX. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of surface roughness among five composites and four polishing systems were 0.01 and 0.01 microm, respectively. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of gloss among five composites and four polishing systems were 6 and 5 GU, respectively. Color differences (deltaE*ab) among five composites and four polishing methods were found to range from 0.2 to 1.1.
Krusinska, Beata; Hawrysz, Iwona; Wadolowska, Lidia; Slowinska, Malgorzata Anna; Biernacki, Maciej; Czerwinska, Anna; Golota, Janusz Jacek
2018-04-11
Lung cancer in men and breast cancer in women are the most commonly diagnosed cancers in Poland and worldwide. Results of studies involving dietary patterns (DPs) and breast or lung cancer risk in European countries outside the Mediterranean Sea region are limited and inconclusive. This study aimed to develop a 'Polish-adapted Mediterranean Diet' ('Polish-aMED') score, and then study the associations between the 'Polish-aMED' score and a posteriori -derived dietary patterns with breast or lung cancer risk in adult Poles. This pooled analysis of two case-control studies involved 560 subjects (280 men, 280 women) aged 40-75 years from Northeastern Poland. Diagnoses of breast cancer in 140 women and lung cancer in 140 men were found. The food frequency consumption of 21 selected food groups was collected using a 62-item Food Frequency Questionnaire (FFQ)-6. The 'Polish-adapted Mediterranean Diet' score which included eight items-vegetables, fruit, whole grain, fish, legumes, nuts and seeds-as well as the ratio of vegetable oils to animal fat and red and processed meat was developed (range: 0-8 points). Three DPs were identified in a Principal Component Analysis: 'Prudent', 'Non-healthy', 'Dressings and sweetened-low-fat dairy'. In a multiple logistic regression analysis, two models were created: crude, and adjusted for age, sex, type of cancer, Body Mass Index (BMI), socioeconomic status (SES) index, overall physical activity, smoking status and alcohol abuse. The risk of breast or lung cancer was lower in the average (3-5 points) and high (6-8 points) levels of the 'Polish-aMED' score compared to the low (0-2 points) level by 51% (odds ratio (OR): 0.49; 95% confidence interval (Cl): 0.30-0.80; p < 0.01; adjusted) and 63% (OR: 0.37; 95% Cl: 0.21-0.64; p < 0.001; adjusted), respectively. In the middle and upper tertiles compared to the bottom tertile of the 'Prudent' DP, the risk of cancer was lower by 38-43% (crude) but was not significant after adjustment for confounders. In the upper compared to the bottom tertile of the 'Non-healthy' DP, the risk of cancer was higher by 65% (OR: 1.65; 95% Cl: 1.05-2.59; p < 0.05; adjusted). In conclusion, the Polish adaptation of the Mediterranean diet could be considered for adults living in non-Mediterranean countries for the prevention of the breast or lung cancers. Future studies should explore the role of a traditional Mediterranean diet fitted to local dietary patterns of non-Mediterranean Europeans in cancer prevention.
Krusinska, Beata; Hawrysz, Iwona; Wadolowska, Lidia; Slowinska, Malgorzata Anna; Biernacki, Maciej; Czerwinska, Anna; Golota, Janusz Jacek
2018-01-01
Lung cancer in men and breast cancer in women are the most commonly diagnosed cancers in Poland and worldwide. Results of studies involving dietary patterns (DPs) and breast or lung cancer risk in European countries outside the Mediterranean Sea region are limited and inconclusive. This study aimed to develop a ‘Polish-adapted Mediterranean Diet’ (‘Polish-aMED’) score, and then study the associations between the ‘Polish-aMED’ score and a posteriori-derived dietary patterns with breast or lung cancer risk in adult Poles. This pooled analysis of two case-control studies involved 560 subjects (280 men, 280 women) aged 40–75 years from Northeastern Poland. Diagnoses of breast cancer in 140 women and lung cancer in 140 men were found. The food frequency consumption of 21 selected food groups was collected using a 62-item Food Frequency Questionnaire (FFQ)-6. The ‘Polish-adapted Mediterranean Diet’ score which included eight items—vegetables, fruit, whole grain, fish, legumes, nuts and seeds—as well as the ratio of vegetable oils to animal fat and red and processed meat was developed (range: 0–8 points). Three DPs were identified in a Principal Component Analysis: ‘Prudent’, ‘Non-healthy’, ‘Dressings and sweetened-low-fat dairy’. In a multiple logistic regression analysis, two models were created: crude, and adjusted for age, sex, type of cancer, Body Mass Index (BMI), socioeconomic status (SES) index, overall physical activity, smoking status and alcohol abuse. The risk of breast or lung cancer was lower in the average (3–5 points) and high (6–8 points) levels of the ‘Polish-aMED’ score compared to the low (0–2 points) level by 51% (odds ratio (OR): 0.49; 95% confidence interval (Cl): 0.30–0.80; p < 0.01; adjusted) and 63% (OR: 0.37; 95% Cl: 0.21–0.64; p < 0.001; adjusted), respectively. In the middle and upper tertiles compared to the bottom tertile of the ‘Prudent’ DP, the risk of cancer was lower by 38–43% (crude) but was not significant after adjustment for confounders. In the upper compared to the bottom tertile of the ‘Non-healthy’ DP, the risk of cancer was higher by 65% (OR: 1.65; 95% Cl: 1.05–2.59; p < 0.05; adjusted). In conclusion, the Polish adaptation of the Mediterranean diet could be considered for adults living in non-Mediterranean countries for the prevention of the breast or lung cancers. Future studies should explore the role of a traditional Mediterranean diet fitted to local dietary patterns of non-Mediterranean Europeans in cancer prevention. PMID:29641468
Da Costa, Juliana; Ferracane, Jack; Paravina, Rade D; Mazur, Rui Fernando; Roeder, Leslie
2007-01-01
The purpose of this in vitro study was to evaluate the surface finish and gloss of five direct resin composites polished with six polishing systems. One hundred and fifty disk-shaped composite specimens (D=10.0 mm, 2-mm-thick, N=30 per material) were made. One side of each specimen was finished with a 16-fluted carbide finishing bur and then polished. Five specimens of each resin composite were randomly assigned to one of the six polishing systems. The surface roughness and gloss were measured with a surface profilometer and a glossmeter. The results were analyzed by two-way analysis of variance and Tukey's t-test (p
[The life of Polish students at the Polish School of Medicine at the University of Edinburgh].
Gebertt, S
1994-01-01
The article has been written by a former student of the Polish School of Medicine at the University of Edinburgh, a member of the Polish Forces in Britain. The reminiscences concentrate on day to day life of others, like himself, seconded from the Forces to continue their medical studies. Statistical data concerning the activities of Polish School of Medicine are presented and analysed. Detailed mention is made of various routes by which Polish students reached Great Britain from the time of defeat and partition of Poland between Germany and Soviet Union. The various phases of relationship and attitudes between Polish Armed Forces and the body of students are described and illustrated by extracts from personal memoirs. The number of other topics is presented and discussed: The difficulties and problems encountered in living and studying amongst people, who although sympathetic, but whose language, culture and customs were completely foreign to the Poles. The ways in which individuals and groups of students tried and in many instances managed to overcome these obstacles, forging links with their Scottish colleagues and population at large. The participation in various joint activities like Settlement Day, work in agricultural camps, sports, Scottish students Unions and Representative Councils etc. are described. "Inner life" of Polish students concentrated in "Bursa" (an equivalent of University Residence) is presented in a light-hearted way. Large detachments of a foreign army, living, amongst albeit friendly population, are bound to cause, sometimes serious, friction. Very much in relation to this problem the role of Polish students as ambassadors of Poland and Polish Causes are presented and their value assessed.
Freddo, Rafael Augusto; Kapczinski, Myriam Pereira; Kinast, Eder Julio; de Souza Junior, Oswaldo Baptista; Rivaldo, Elken Gomes; da Fontoura Frasca, Luis Carlos
2016-10-01
To evaluate, by means of pin-on-disk testing, the wear potential of different dental ceramic systems as it relates to friction parameters, surface finish, and microhardness. Three groups of different ceramic systems (Noritake EX3, Eris, Empress II) with 20 disks each (10 glazed, 10 polished) were used. Vickers microhardness (Hv) was determined with a 200-g load for 30 seconds. Friction coefficients (μ) were determined by pin-on-disk testing (5 N load, 600 seconds, and 120 rpm). Wear patterns were assessed by scanning electron microscopy (SEM). The results were analyzed using one-way ANOVA and Tukey's test, with the significance level set at α = 0.05. The coefficients of friction were as follows: Noritake EX3 0.28 ± 0.12 (polished), 0.33 ± 0.08 (glazed); Empress II 0.38 ± 0.08 (polished), 0.45 ± 0.05 (glazed); Eris 0.49 ± 0.05 (polished), 0.49 ± 0.06 (glazed). Microhardness measurements were as follows: Noritake EX3 530.7 ± 8.7 (polished), 525.9 ± 6.2 (glazed); Empress II 534.1 ± 8 (polished), 534.7 ± 4.5 (glazed); Eris, 511.7 ± 6.5 (polished), 519.5 ± 4.1 (glazed). The polished and glazed Noritake EX3 and polished and glazed Eris specimens showed statistically different friction coefficients. SEM image analysis revealed more surface changes, such as small cracks and grains peeling off, in glazed ceramics. Wear potential may be related to the coefficient of friction in Noritake ceramics, which had a lower coefficient than Eris ceramics. Within-group analysis showed no differences in polished or glazed specimens. The differences observed were not associated with microhardness. © 2015 by the American College of Prosthodontists.
Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata
2016-01-01
Introduction Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. Material and methods We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. Results The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish (p > 0.05). Conclusions More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication. PMID:29593808
Glinkowski, Wojciech M; Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata
2018-03-01
Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish ( p > 0.05). More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication.
Optimized method for manufacturing large aspheric surfaces
NASA Astrophysics Data System (ADS)
Zhou, Xusheng; Li, Shengyi; Dai, Yifan; Xie, Xuhui
2007-12-01
Aspheric optics are being used more and more widely in modern optical systems, due to their ability of correcting aberrations, enhancing image quality, enlarging the field of view and extending the range of effect, while reducing the weight and volume of the system. With optical technology development, we have more pressing requirement to large-aperture and high-precision aspheric surfaces. The original computer controlled optical surfacing (CCOS) technique cannot meet the challenge of precision and machining efficiency. This problem has been thought highly of by researchers. Aiming at the problem of original polishing process, an optimized method for manufacturing large aspheric surfaces is put forward. Subsurface damage (SSD), full aperture errors and full band of frequency errors are all in control of this method. Lesser SSD depth can be gained by using little hardness tool and small abrasive grains in grinding process. For full aperture errors control, edge effects can be controlled by using smaller tools and amendment model with material removal function. For full band of frequency errors control, low frequency errors can be corrected with the optimized material removal function, while medium-high frequency errors by using uniform removing principle. With this optimized method, the accuracy of a K9 glass paraboloid mirror can reach rms 0.055 waves (where a wave is 0.6328μm) in a short time. The results show that the optimized method can guide large aspheric surface manufacturing effectively.
Lenarczyk, Radosław; Mitręga, Katarzyna; Mazurek, Michał; Janion, Marianna; Opolski, Grzegorz; Drożdż, Jarosław; Streb, Witold; Fuglewicz, Artur; Sokal, Adam; Laroche, Cécile; Lip, Gregory Y H; Kalarus, Zbigniew
2016-01-01
Despite continued efforts of the European Society of Cardiology (ESC) to unify management of patients with atrial fibrillation (AF) across Europe, interregional differences in guideline adherence are likely. The aim of the study was to compare treatment strategies depending on baseline characteristics of AF patients between Poland and other members of the European Union (EU). We analyzed the baseline data and treatment strategies in participants of the ESC registry: the EURObservational Research Programme-Atrial Fibrillation General Registry Pilot Phase. A total of 3119 consecutive patients with AF diagnosed within the last year were included in 67 centers from 9 countries, including 419 patients enrolled in 15 Polish centers. A rhythm control strategy was more frequent in Poland than in other EU countries (20.8% vs 11.9%; P <0.0001). Catheter ablation for AF was also used more frequently in Polish cardiology wards (13.9% vs 8.3%; P = 0.0017), while amiodarone at discharge was used less frequently (12.0% vs 22.7%; P <0.0001). In-hospital use of vitamin K antagonists (VKAs) and non-VKA anticoagulants was less frequent in Polish patients with a CHA2DS2-VASc score of 2 or higher than in patients from other EU countries (61.1% vs 79.0%; P <0.0001), but overall anticoagulation rates at discharge were similar to those in other countries (83.3% vs 82.6%). A rhythm control-oriented strategy in patients with AF with the use of ablation in cardiology wards is more frequent in Poland than in other EU countries. Similar to other EU countries, compliance with the ESC guidelines regarding anticoagulation in AF patients is suboptimal in Poland. Undertreatment was observed in a significant proportion of patients at high risk of stroke, while a large group of low-risk patients are overtreated. Differences between the types of recruiting centers in Poland and other EU countries might have influenced the results.
Schmidlin, Patrick R; Fujioka-Kobayashi, Masako; Mueller, Heinz-Dieter; Sculean, Anton; Lussi, Adrian; Miron, Richard J
2017-06-01
The aim of this study is to examine morphological changes of dentin surfaces following air polishing or amino acid buffered hypochlorite solution application and to assess their influence on periodontal ligament (PDL) cell survival, attachment, and spreading to dentin discs in vitro. Bovine dentin discs were treated with either (i) Classic, (ii) Plus, or (iii) Perio powder (EMS). Furthermore, Perisolv® a hypochlorite solution buffered with various amino acids was investigated. Untreated dentin discs served as controls. Morphological changes to dentin discs were assessed using scanning electron microscopy (SEM). Human PDL cells were seeded onto the respectively treated discs, and samples were then investigated for PDL cell survival, attachment, and spreading using a live/dead assay, adhesion assay, and SEM imaging, respectively. Both control and Perisolv®-rinsed dentin discs demonstrated smooth surfaces at low and high magnifications. The Classic powders demonstrated the thickest coating followed by the Powder Plus. The Perio powder demonstrated marked alterations of dentin discs by revealing the potential to open dentinal tubules even before rinsing. Seeding of PDL cells demonstrated an almost 100 % survival rate on all samples demonstrating very high biocompatibility for all materials. Significantly higher PDL cell numbers were observed on samples treated with the Perio powder and the Perisolv® solution (approximately 40 % more cells; p < 0.05). SEM imaging revealed the potential for PDL cells to attach and spread on all surfaces. The results from the present study demonstrate that cell survival and spreading of PDL cells on root surfaces is possible following either air polishing or application with Perisolv®. Future in vitro and animal testing is necessary to further characterize the beneficial effects of either system in a clinical setting. The use of air polishing or application with Perisolv amino acid buffered hypochlorite solution was effective in treating root surfaces and allowed for near 100 % PDL cell survival, attachment, and spreading onto all root surfaces.
Williamson Polishing & Plating Site
Williamson Polishing & Plating Co. Inc. was a plating shop located in the Martindale-Brightwood neighborhood of Indianapolis. The facility conducted job shop polishing and electroplating services. The vacant site contains a 14,651-square-foot building.
NASA Astrophysics Data System (ADS)
Wang, Guilian; Zhou, Xiaoqin; Ma, Peiqun; Wang, Rongqi; Meng, Guangwei; Yang, Xu
2018-01-01
The vibration assisted polishing has widely application fields because of higher machining frequency and better polishing quality, especially the polishing with the non-resonant mode that is regarded as a kind of promising polishing method. This paper reports a novel vibration assisted polishing device, consisting of the flexible hinge mechanism driven by the piezoelectric actuators, which is suitable for polishing planes or curve surfaces with slow curvature. Firstly, the generation methods of vibration trajectory are investigated for the same frequency and different frequency signals' inputs, respectively, and then the types of elliptic and Lissajous's vibration trajectories are generated respectively. Secondly, a flexural mechanism consisting of the right circular flexible hinges and the leaf springs is developed to produce two-dimensional vibration trajectory. Statics and dynamics investigating of this flexible mechanism are finished in detail. The analytical models about input and output compliances of the flexural mechanism are established according to the matrix-based compliance modeling, and the dynamic model of the flexural mechanism based on the Euler-Lagrange equation is also presented. The finite element model of the flexural mechanism was established to carry out the numerical simulation in order to testify the rationality of device design. Finally, the polishing experiment is carried out to prove the effectiveness of the vibration device. The experimental results show that this novel vibration assisted polishing device developed in this study can remove more effectively the cutting marks left by last process and obviously reduce the workpiece surface roughness.
Butler, Samuel D; Nauyoks, Stephen E; Marciniak, Michael A
2015-06-01
Of the many classes of bidirectional reflectance distribution function (BRDF) models, two popular classes of models are the microfacet model and the linear systems diffraction model. The microfacet model has the benefit of speed and simplicity, as it uses geometric optics approximations, while linear systems theory uses a diffraction approach to compute the BRDF, at the expense of greater computational complexity. In this Letter, nongrazing BRDF measurements of rough and polished surface-reflecting materials at multiple incident angles are scaled by the microfacet cross section conversion term, but in the linear systems direction cosine space, resulting in great alignment of BRDF data at various incident angles in this space. This results in a predictive BRDF model for surface-reflecting materials at nongrazing angles, while avoiding some of the computational complexities in the linear systems diffraction model.
Cipora, Krzysztof; Szczygieł, Monika; Willmes, Klaus; Nuerk, Hans-Christoph
2015-01-01
Math anxiety has an important impact on mathematical development and performance. However, although math anxiety is supposed to be a transcultural trait, assessment instruments are scarce and are validated mainly for Western cultures so far. Therefore, we aimed at examining the transcultural generality of math anxiety by a thorough investigation of the validity of math anxiety assessment in Eastern Europe. We investigated the validity and reliability of a Polish adaptation of the Abbreviated Math Anxiety Scale (AMAS), known to have very good psychometric characteristics in its original, American-English version as well as in its Italian and Iranian adaptations. We also observed high reliability, both for internal consistency and test-retest stability of the AMAS in the Polish sample. The results also show very good construct, convergent and discriminant validity: The factorial structure in Polish adult participants (n = 857) was very similar to the one previously found in other samples; AMAS scores correlated moderately in expected directions with state and trait anxiety, self-assessed math achievement and skill as well temperamental traits of emotional reactivity, briskness, endurance, and perseverance. Average scores obtained by participants as well as gender differences and correlations with external measures were also similar across cultures. Beyond the cultural comparison, we used path model analyses to show that math anxiety relates to math grades and self-competence when controlling for trait anxiety. The current study shows transcultural validity of math anxiety assessment with the AMAS. PMID:26648893
Cipora, Krzysztof; Szczygieł, Monika; Willmes, Klaus; Nuerk, Hans-Christoph
2015-01-01
Math anxiety has an important impact on mathematical development and performance. However, although math anxiety is supposed to be a transcultural trait, assessment instruments are scarce and are validated mainly for Western cultures so far. Therefore, we aimed at examining the transcultural generality of math anxiety by a thorough investigation of the validity of math anxiety assessment in Eastern Europe. We investigated the validity and reliability of a Polish adaptation of the Abbreviated Math Anxiety Scale (AMAS), known to have very good psychometric characteristics in its original, American-English version as well as in its Italian and Iranian adaptations. We also observed high reliability, both for internal consistency and test-retest stability of the AMAS in the Polish sample. The results also show very good construct, convergent and discriminant validity: The factorial structure in Polish adult participants (n = 857) was very similar to the one previously found in other samples; AMAS scores correlated moderately in expected directions with state and trait anxiety, self-assessed math achievement and skill as well temperamental traits of emotional reactivity, briskness, endurance, and perseverance. Average scores obtained by participants as well as gender differences and correlations with external measures were also similar across cultures. Beyond the cultural comparison, we used path model analyses to show that math anxiety relates to math grades and self-competence when controlling for trait anxiety. The current study shows transcultural validity of math anxiety assessment with the AMAS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olofinjana, Bolutife; Lorenzo-Martin, Cinta; Ajayi, Oyelayo O.
Surface texturing or topographical design is one of the primary techniques to control friction and wear performance of surfaces in tribological contact. Laser surface texturing (LST), whereby a laser beam is used to produce regular arrays of dimples on a surface, has been demonstrated to reduce friction in conformal lubricated contacts. Friction and wear behavior under boundary lubrication is also known to be dependent on the formation and durability of the tribochemical film formed from lubricant additives. In this paper, the effects of LST on the formation and durability of tribochemical films and its consequent impacts on friction and wearmore » behavior in various lubrication regimes were evaluated. Friction and wear tests that cycled through different lubrication regimes were conducted with both polished and LST treated surfaces using a synthetic lubricant with and without model additives of ZDDP and MoDTC mixture. In the base oil without additives, LST produced noticeable reduction in friction in all lubrication regimes. However, with low-friction model additives, friction was higher in tests with LST due to significant differences in the tribochemical film formation in the polished and LST surfaces, as well as the sliding counterface. Continuous tribo-films were formed on ball conterface rubbed against polished surfaces while the films were streaky and discontinuous in ball rubbed against LST surfaces. LST produced more wear on the ball counterface in both base and additized oils. Lastly, no measurable wear was observed in both the polished and LST flat specimens.« less
Uppal, Mudit; Ganesh, Arathi; Balagopal, Suresh; Kaur, Gurleen
2013-07-01
To evaluate the effect of three polishing protocols that could be implemented at recall on the surface roughness of two direct esthetic restorative materials. Specimens (n = 40) measuring 8 mm (length) × 5 mm (width) × 4 mm (height) were fabricated in an acrylic mold using two light-cured resin-based materials (microfilled composite and microhybrid composite). After photopolymerization, all specimens were finished and polished with one of three polishing protocols (Enhance, One Gloss, and Sof-Lex polishing systems). The average surface roughness of each treated specimen was determined using 3D optical profilometer. Next all specimens were brushed 60,000 times with nylon bristles at 7200 rpm using crosshead brushing device with equal parts of toothpaste and water used as abrasive medium. The surface roughness of each specimen was measured after brushing followed by repolishing with one of three polishing protocols, and then, the final surface roughness values were determined. The data were analyzed using one-way and two-factor analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD). Significant difference (P < 0.05) in surface roughness was observed. Simulated brushing following initial polishing procedure significantly roughened the surface of restorative material (P < 0.05). Polishing protocols can be used to restore a smooth surface on esthetic restorative materials following simulated tooth brushing.
Gloss and surface roughness produced by polishing kits on resin composites.
Sadidzadeh, Ramtin; Cakir, Deniz; Ramp, Lance C; Burgess, John O
2010-08-01
To compare in vitro the surface roughness (Ra) and gloss (G) produced by three conventional and one experimental polishing kits on four resin composites. 24 discs were prepared (d = 12 mm, t = 4 mm) for each resin composite: Filtek Supreme Plus Body/A2 (FSB), Yellow Translucent (FST), Heliomolar/A2 (HM), and EsthetX/A2 (EX) following the manufacturers' instructions. They were finished with 320 grit silicon carbide paper for 80 seconds each. Polishing systems: Sof-Lex, Enhance-Pogo, Astropol and Experimental Discs/EXL-695, were applied following manufacturers' instructions. Each specimen was ultrasonically cleaned with distilled water and dried. Gloss and Ra were measured with a small area glossmeter (Novo-curve) and non-contact profilometer (Proscan 2000) following ISO 4288, respectively. The results were evaluated by two-way ANOVA followed by separate one-way ANOVA and Tukey/Kramer test (P = 0.05). There was a significant interaction of surface roughness and gloss between the composites and polishing systems (P < 0.05). The lowest surface roughness was recorded for FST polished with the Experimental kit. The highest gloss was obtained for FSB composite polished with the Experimental kit. The experimental polishing system produced smoothest surfaces (P < 0.05). The Enhance-Pogo and the experimental polishing kit produced highest gloss (P < 0.05).
Fabrication of an optical component
Nichols, Michael A.; Aikens, David M.; Camp, David W.; Thomas, Ian M.; Kiikka, Craig; Sheehan, Lynn M.; Kozlowski, Mark R.
2000-01-01
A method for forming optical parts used in laser optical systems such as high energy lasers, high average power lasers, semiconductor capital equipment and medical devices. The optical parts will not damage during the operation of high power lasers in the ultra-violet light range. A blank is first ground using a fixed abrasive grinding method to remove the subsurface damage formed during the fabrication of the blank. The next step grinds and polishes the edges and forms bevels to reduce the amount of fused-glass contaminants in the subsequent steps. A loose abrasive grind removes the subsurface damage formed during the fixed abrasive or "blanchard" removal process. After repolishing the bevels and performing an optional fluoride etch, the surface of the blank is polished using a zirconia slurry. Any subsurface damage formed during the loose abrasive grind will be removed during this zirconia polish. A post polish etch may be performed to remove any redeposited contaminants. Another method uses a ceria polishing step to remove the subsurface damage formed during the loose abrasive grind. However, any residual ceria may interfere with the optical properties of the finished part. Therefore, the ceria and other contaminants are removed by performing either a zirconia polish after the ceria polish or a post ceria polish etch.
NASA Astrophysics Data System (ADS)
Sun, Zhiyuan; Guo, Bing; Rao, Zhimin; Zhao, Qingliang
2014-08-01
In consideration of the excellent property of SiC, the ground micro-structured surface quality is hard to meet the requirement - consequently the ultrasonic vibration assisted polishing (UVAP) of micro-structures of molds is proposed in this paper. Through the orthogonal experiment, the parameters of UVAP of micro-structures were optimized. The experimental results show that, abrasive polishing process, the effect of the workpiece feed rate on the surface roughness (Ra), groove tip radius (R) and material removal rate (MRR) of micro-structures is significant. While, the UVAP, the most significant effect factor for Ra, R and MRR is the ultrasonic amplitude of the ultrasonic vibration. In addition, within the scope of the polishing process parameters selected by preliminary experiments, ultrasonic amplitude of 2.5μm, polishing force of 0.5N, workpiece feed rate of 5 mm·min-1, polishing wheel rotational speed of 50rpm, polishing time of 35min, abrasive size of 100nm and the polishing liquid concentration of 15% is the best technology of UVAP of micro-structures. Under the optimal parameters, the ground traces on the micro-structured surface were removed efficiently and the integrity of the edges of the micro-structure after grinding was maintained efficiently.
ERIC Educational Resources Information Center
Tobacyk, Jerome J.; Tobacyk, Zofia Socha
1992-01-01
Uses Social Learning Theory to compare 149 university students from Poland with 136 university students from the southern United States for belief-based personality constructs and personality correlates of paranormal beliefs. As hypothesized, Poles reported a more external locus of control and significantly greater endorsement of irrational…
The Cerrito Site (AR-4): A Piedra Lumbre Phase Settlement at Abiquiu Reservoir,
1979-11-01
entirely or partially with well-polished slip and * which were not painted. Diffeential firing and smudging techniques render the vessels red, black, gray...collapsed. The single carbon-14 date is rendered suspicious because of the Suess effect (Samon et al. 1974). However, the influence of this effect in the...dates of 0 A.D. 1107 and A.D. 792. The 2 oldest readings from the lithic areas (specimens 5621 and 5632) are rendered suspicious when computed with the
Electrochemical Polishing Applications and EIS of a Vitamin B{sub 4}-Based Ionic Liquid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.
2013-01-01
Modern particle accelerators require minimal interior surface roughness for Niobium superconducting radio frequency (SRF) cavities. Polishing of the Nb is currently achieved via electrochemical polishing with concentrated mixtures of sulfuric and hydrofluoric acids. This acid-based approach is effective at reducing the surface roughness to acceptable levels for SRF use, but due to acid-related hazards and extra costs (including safe disposal of used polishing solutions), an acid-free method would be preferable. This study focuses on an alternative electrochemical polishing method for Nb, using a novel ionic liquid solution containing choline chloride, also known as Vitamin B{sub 4} (VB{sub 4}). Potentiostatic electrochemicalmore » impedance spectroscopy (EIS) was also performed on the VB4-based system. Nb polished using the VB4-based method was found to have a final surface roughness comparable to that achieved via the acid-based method, as assessed by atomic force microscopy (AFM). These findings indicate that acid-free VB{sub 4}-based electrochemical polishing of Nb represents a promising replacement for acid-based methods of SRF cavity preparation.« less
Laser polishing of additive manufactured Ti alloys
NASA Astrophysics Data System (ADS)
Ma, C. P.; Guan, Y. C.; Zhou, W.
2017-06-01
Laser-based additive manufacturing has attracted much attention as a promising 3D printing method for metallic components in recent years. However, surface roughness of additive manufactured components has been considered as a challenge to achieve high performance. In this work, we demonstrate the capability of fiber laser in polishing rough surface of additive manufactured Ti-based alloys as Ti-6Al-4V and TC11. Both as-received surface and laser-polished surfaces as well as cross-section subsurfaces were analyzed carefully by White-Light Interference, Confocal Microscope, Focus Ion Beam, Scanning Electron Microscopy, Energy Dispersive Spectrometer, and X-ray Diffraction. Results revealed that as-received Ti-based alloys with surface roughness more than 5 μm could be reduce to less than 1 μm through laser polishing process. Moreover, microstructure, microhardness and wear resistance of laser-polished zone was investigated in order to examine the thermal effect of laser polishing processing on the substrate of additive manufactured Ti alloys. This proof-of-concept process has the potential to effectively improve the surface roughness of additive manufactured metallic alloy by local polishing method without damage to the substrate.
Cieśla, Elżbieta; Mleczko, Edward; Bergier, Józef; Markowska, Małgorzata; Nowak-Starz, Grażyna
2014-01-01
The objective of the study was determination of the effect of various forms of physical activity, BMI, and time devoted to computer games on the level of Health-Related Physical Fitness (H-RF) in 6-7-year-old children from Polish rural areas. The study covered 25,816 children aged 6-7: 12,693 girls and 13,123 boys. The evaluations included body height and weight, and 4 H-RF fitness components (trunk strength, explosive leg power, arm strength and flexibility). The BMI was calculated for each child. The Questionnaire directed to parents was designed to collect information concerning the time devoted by children to computer games, spontaneous and additional physical activity. The strength of the relationships between dependent and independent variables was determined using the Spearman's rank correlation (RSp), and the relationship by using the regression analysis. The BMI negatively affected the level of all the H-RF components analysed (p=0.000). The negative effect of computer games revealed itself only with respect to flexibility (p=0.000), explosive leg power (p=0.000) and trunk muscle strength (p=0.000). A positive effect of spontaneous activity was observed for flexibility (p=0.047), explosive leg power (p=0.000), and arm strength (p=0.000). Additional activity showed a positive relationship with trunk muscles strength (p=0.000), and explosive leg power (p=0.000). The results of studies suggest that it is necessary to pay attention to the prevention of diseases related with the risk of obesity and overweight among Polish rural children as early as at pre-school age. There is also a need during education for shaping in these children the awareness of concern about own body, and the need for active participation in various forms of physical activity.
Weight discrepancy and body appreciation among women in Poland and Britain.
Taylor, Donna; Szpakowska, Ilona; Swami, Viren
2013-09-01
Previous studies have suggested that the process of transmigration has detrimental effects on the body image of migrants relative to women in the country of origin. In the present work, we examined the body image of Polish migrants in Britain (n=153), Polish women in Poland (n=153), and a comparison group of British White women (n=110). Participants completed a measure of actual-ideal weight discrepancy and the Body Appreciation Scale (BAS). Contrary to hypotheses, our results showed that Polish women in Poland had significantly higher weight discrepancy than their counterparts in Britain. Further analyses showed that the BAS reduced to two dimensions among Polish participants, with Polish participants in Poland having significantly lower body appreciation than Polish migrants. We suggest that the sociocultural changes that have taken place in Eastern Europe may place women in that region at relatively high risk for developing negative body image. Copyright © 2013 Elsevier Ltd. All rights reserved.
Samochowiec, Agnieszka; Chęć, Magdalena; Kopaczewska, Edyta; Samochowiec, Jerzy; Lesch, Otto; Grochans, Elżbieta; Jasiewicz, Andrzej; Bienkowski, Przemyslaw; Łukasz, Kołodziej; Grzywacz, Anna
2015-01-01
Background: The aim of this study was to examine the association between the MAOA-uVNTR gene polymorphism in a homogeneous subgroups of patients with alcohol dependence categorized according to Lesch’s typology. Methods: DNA was provided from alcohol dependent (AD) patients (n = 370) and healthy control subjects (n = 168) all of Polish descent. The history of alcoholism was obtained using the Polish version of the Semi-Structured Assessment for the Genetics of Alcoholism (SSAGA). Samples were genotyped using PCR methods. Results: We found no association between alcohol dependence and MAOA gene polymorphism. Conclusions: Lesch typology is a clinical consequence of the disease and its phenotypic description is too complex for a simple genetic analysis. PMID:25809512
Paziewska, Agnieszka; Cukrowska, Bozena; Dabrowska, Michalina; Goryca, Krzysztof; Piatkowska, Magdalena; Kluska, Anna; Mikula, Michal; Karczmarski, Jakub; Oralewska, Beata; Rybak, Anna; Socha, Jerzy; Balabas, Aneta; Zeber-Lubecka, Natalia; Ambrozkiewicz, Filip; Konopka, Ewa; Trojanowska, Ilona; Zagroba, Malgorzata; Szperl, Malgorzata; Ostrowski, Jerzy
2015-01-01
Assessment of non-HLA variants alongside standard HLA testing was previously shown to improve the identification of potential coeliac disease (CD) patients. We intended to identify new genetic variants associated with CD in the Polish population that would improve CD risk prediction when used alongside HLA haplotype analysis. DNA samples of 336 CD and 264 unrelated healthy controls were used to create DNA pools for a genome wide association study (GWAS). GWAS findings were validated with individual HLA tag single nucleotide polymorphism (SNP) typing of 473 patients and 714 healthy controls. Association analysis using four HLA-tagging SNPs showed that, as was found in other populations, positive predicting genotypes (HLA-DQ2.5/DQ2.5, HLA-DQ2.5/DQ2.2, and HLA-DQ2.5/DQ8) were found at higher frequencies in CD patients than in healthy control individuals in the Polish population. Both CD-associated SNPs discovered by GWAS were found in the CD susceptibility region, confirming the previously-determined association of the major histocompatibility (MHC) region with CD pathogenesis. The two most significant SNPs from the GWAS were rs9272346 (HLA-dependent; localized within 1 Kb of DQA1) and rs3130484 (HLA-independent; mapped to MSH5). Specificity of CD prediction using the four HLA-tagging SNPs achieved 92.9%, but sensitivity was only 45.5%. However, when a testing combination of the HLA-tagging SNPs and the MSH5 SNP was used, specificity decreased to 80%, and sensitivity increased to 74%. This study confirmed that improvement of CD risk prediction sensitivity could be achieved by including non-HLA SNPs alongside HLA SNPs in genetic testing.
Fila-Danilow, Anna; Kucia, Krzysztof; Kowalczyk, Malgorzata; Owczarek, Aleksander; Paul-Samojedny, Monika; Borkowska, Paulina; Suchanek, Renata; Kowalski, Jan
2012-08-01
Changes in immunological system are one of dysfunctions reported in schizophrenia. Some changes based on an imbalance between Th1 and Th2 cytokines results from cytokine gene polymorphisms. Interleukin-4 gene (IL4) is considered as a potential candidate gene in schizophrenia association studies. The aim of the current case-control study was to examine whether the -590C/T (rs2243250) and -33C/T (rs2070874) IL4 gene polymorphisms are implicated in paranoid schizophrenia development in the Polish population. Genotyping of polymorphisms was performed by using PCR-RFLP technique. The genotypes and alleles distribution of both SNPs were analysed in patients (n = 182) and healthy individuals constituted the control group (n = 215). The connection between some clinical variables and studied polymorphisms has been examined as well. We did not revealed any association between the -590C/T and -33C/T polymorphisms and paranoid schizophrenia. In case of both SNPs the homozygous TT genotype was extremely rare. Both polymorphic sites of the IL4 gene were found to be in a very strong linkage disequilibrium. However we did not identify a haplotype predispose to paranoid schizophrenia. No associations were also observed between the clinical course and psychopathology of the disease and the genotypes of both analysed polymorphisms. Our results suggest that the polymorphisms -590C/T in IL4 gene promoter region and -33C/T in the 5'-UTR are not involved in the pathophysiology of paranoid schizophrenia in Polish residents.
Fundamental studies on silicon dioxide chemical mechanical polishing
NASA Astrophysics Data System (ADS)
Mahajan, Uday
Chemical Mechanical Polishing (CMP) has lately been adopted on a large scale by the semiconductor industry for planarizing and patterning metal and dielectric films. Additionally, CMP has been used for hundreds of years for optical polishing. Still, several aspects of this process remain poorly understood. In this study, some results on CMP of SiO2 are presented with a view to characterizing the effects of abrasive properties and slurry chemistry on the polishing process. Additionally, some results from a novel in-situ friction force measuring instrument are also presented. The friction force results showed the effect of several parameters such as surface roughness, solution pH and ionic strength on wafer-pad interactions. Additionally, monitoring the friction as a function of velocity showed that the transition from boundary lubrication to full fluid-film lubrication depends on the roughness (conditioning) of the polishing pad. The parameters investigated in the polishing experiments include abrasive size and concentration. From the experimental results, it was found that an optimum concentration exists for each abrasive size, which shifts to lower values and becomes narrower as particle size increases. From calculations, this was attributed to a decreased ability of the large particles to chemically modify the surface of the SiO2 films. The smaller particles, having a much larger surface area, are able to better adsorb dissolution and abrasion products at high concentrations, thus leading to high removal rates under those conditions. Studies on the effect of slurry ionic strength showed that the ability of a metal ion to shield the surface charge on the surfaces interacting during polishing is what determined removal rate. This was due to the reduced electrostatic repulsion between the surfaces, which resulted in better contact and thus higher polishing rates. These results were corroborated by the earlier friction force measurements. Finally, the influence of particle density on polishing was shown, with denser alumina particles being able to polish SiO2 much more effectively. Some preliminary results on polishing with different abrasives as a function of slurry pH indicate that the material properties of the abrasives seem to change around their Iso-electric Points (IEP), resulting in almost no polishing, and severe particle contamination on the SiO2 surface.
Thin Shell Manufacturing for large Wavefront correctors
NASA Astrophysics Data System (ADS)
Ruch, Eric; Poutriquet, Florence
2011-09-01
One of the major key elements in large adaptive optical systems is the thin shell, used as a deformable mirror. Although the optical prescriptions are relaxed with respect to a passive mirror, especially in the low spatial frequency domain, other requirements, such as the cosmetic defects (scratch & dig), the tight control of the thickness uniformity and of course the fragility of the piece having an aspect ratio up to 1000:1, generate new problems during the manufacturing, testing and handling of such optics. Moreover, the optical surface has to be tested in two different ways: a classical optical test bench allows us to create a surface map of the mirror. This map is then computed to determine the force required by the actuators to flatten the mirror and this becomes also a specification for polishing and implies a good interaction with the voice coil manufacturer. More than twenty years ago Sagem - Reosc developed the first meter class thin shell for early adaptive optics experiments. Since then, large thin shell have been used as the optical part in composite mirrors and more recently the aspheric shell for the VLT Deformable Secondary Mirror has been polished and prototypes, up to scale 1, of the E-ELT M4 Adaptive Mirror have been delivered to ESO in 2010. This paper will present some recent results in the manufacturing and testing technologies of large this shell, especially focusing on the development of the 1,1 meter convex aspherical shell for the VLT M2 mirror and on the results obtained on the largest thin shell produced so far (2,5 meter in diameter) developed as a demonstrator for the future E-ELT M4.
Ion beam figuring of silicon aspheres
NASA Astrophysics Data System (ADS)
Demmler, Marcel; Zeuner, Michael; Luca, Alfonz; Dunger, Thoralf; Rost, Dirk; Kiontke, Sven; Krüger, Marcus
2011-03-01
Silicon lenses are widely used for infrared applications. Especially for portable devices the size and weight of the optical system are very important factors. The use of aspherical silicon lenses instead of spherical silicon lenses results in a significant reduction of weight and size. The manufacture of silicon lenses is more challenging than the manufacture of standard glass lenses. Typically conventional methods like diamond turning, grinding and polishing are used. However, due to the high hardness of silicon, diamond turning is very difficult and requires a lot of experience. To achieve surfaces of a high quality a polishing step is mandatory within the manufacturing process. Nevertheless, the required surface form accuracy cannot be achieved through the use of conventional polishing methods because of the unpredictable behavior of the polishing tools, which leads to an unstable removal rate. To overcome these disadvantages a method called Ion Beam Figuring can be used to manufacture silicon lenses with high surface form accuracies. The general advantage of the Ion Beam Figuring technology is a contactless polishing process without any aging effects of the tool. Due to this an excellent stability of the removal rate without any mechanical surface damage is achieved. The related physical process - called sputtering - can be applied to any material and is therefore also applicable to materials of high hardness like Silicon (SiC, WC). The process is realized through the commercially available ion beam figuring system IonScan 3D. During the process, the substrate is moved in front of a focused broad ion beam. The local milling rate is controlled via a modulated velocity profile, which is calculated specifically for each surface topology in order to mill the material at the associated positions to the target geometry. The authors will present aspherical silicon lenses with very high surface form accuracies compared to conventionally manufactured lenses.
Sobański, Jerzy A; Klasa, Katarzyna; Rutkowski, Krzysztof; Dembińska, Edyta; Müldner-Nieckowski, Łukasz; Cyranka, Katarzyna
2013-01-01
Assessment of reliability, cross-validity and usefulness in everyday clinical practice of two related tools: Social Avoidance and Distress Scale (SAD) and Fear of Negative Evaluation Scale (FNE). Analysis of tests results of 453 females and 172 males diagnosed in the years 2008-2010 in the Outpatient Clinic for Neurotic and Behavioral Disorders of the Cracow University Hospital, including, inter alia, results of the questionnaires SAD and FNE. The scales have been, with the consent of their authors (R. Friend) and the copyright holder (APA), translated into Polish and back-translated. Subjects also completed the symptom checklist KO '0'(n = 512), and neurotic personality questionnaire KON-2006 (n = 505), as well as the NEO-PI-R personality inventory (n = 46). The reliability and cross-validity coefficients of Polish versions were assessed in the patient population and their results were compared with those of the group of 75 medical students. The translation was verified by retranslation. The reliability coefficients of Polish version of the SAD and FNE scales turned out to be high--Cronbach's alpha coefficient was 0.94 for both scales, Guttman's split-half reliability coefficient 0.93. Correlations with symptom checklist KO '0 'and neurotic personality questionnaire KON-2006, as well as with the NEO -PI-R personality inventory were significant and indicate a good cross-validity of the analyzed tools. The average results in the patient population for both scales were significantly higher than the results in the preliminary control group of medical students. Polish versions of SAD and FNE questionnaires, like their other translations from English, proved to be reliable and have a high cross-validity with other original Polish tools used in the diagnosis of neurotic disorders, which allows to recommend them to be used in further studies, also in comparing healthy persons with those suffering from a variety of neurotic disorders.
Trobos, Margarita; Johansson, Martin Lars; Jonhede, Sofia; Peters, Hanna; Hoffman, Maria; Omar, Omar; Thomsen, Peter; Hultcrantz, Malou
2018-06-01
In this prospective clinical pilot study, abutments with different topologies (machined versus polished) were compared with respect to the clinical outcome and the microbiological profile. Furthermore, three different sampling methods (retrieval of abutment, collection of peri-abutment exudate using paper-points, and a small peri-abutment soft-tissue biopsy) were evaluated for the identification and quantification of colonising bacteria. Twelve patients, seven with machined abutment and five with polished abutment, were included in the analysis. Three different sampling procedures were employed for the identification and quantification of colonising bacteria from baseline up to 12 months, using quantitative culturing. Clinical outcome measures (Holgers score, hygiene, pain, numbness and implant stability) were investigated. The clinical parameters, and total viable bacteria per abutment or in tissue biopsies did not differ significantly between the polished and machined abutments. The total CFU/mm 2 abutment and CFU/peri-abutment fluid space of anaerobes, aerobes and staphylococci were significantly higher for the polished abutment. Anaerobic bacteria were detected in the tissue biopsies before BAHS implantation. Anaerobes and Staphylococcus spp. were detected in all three compartments after BAHS installation. For most patients (10/12), the same staphylococcal species were found in at least two of the three compartments at the same time-point. The common skin coloniser Staphylococcus epidermidis was identified in all patients but one (11/12), whereas the pathogen Staphylococcus aureus was isolated in five of the patients. Several associations between clinical and microbiological parameters were found. There was no difference in the clinical outcome with the use of polished versus machined abutment at 3 and 12 months after implantation. The present pilot trial largely confirmed a suitable study design, sampling and analytical methodology to determine the effects of modified BAHS abutment properties. 2. Controlled prospective comparative study.
Jadhav, Sonali S; Mahajan, Neerja; Sethuraman, Rajesh
2018-01-01
Heat cure acrylic resin material with reduced monomer content is generally recommended for clinical usage as it leads to improved mechanical, physical, and biocompatibility properties. The purpose of the present study was to evaluate and compare the amount of the residual monomer in the conventional and three different groups of deep-frozen heat cure polymethylmethacrylate (PMMA) acrylic resin. Totally 40 Specimens of heat cure PMMA acrylic resin (DPI India) (10 conventional heat cure and 30 deep frozen) were made using two disc-shaped stainless steel molds and invested into type II dental stone using compression molding technique. Each group contained 10 specimens ( n = 10). Group 1: Control group of conventional polished PMMA specimen stored in water for 24 h at +37°C (10 specimens), Group 2: Deep frozen unpolished PMMA (10 specimens), Group 3: Deep frozen polished PMMA (10 specimens), and Group 4: Deep frozen polished PMMA specimen stored in water for 24 h at +37°C (10 specimens). Amount of the residual monomer content in all the specimens was measured using high-performance liquid chromatography. Data were analyzed using One-Way Analysis of Variance and multiple comparison Tukey's post hoc test (α = 0.05). Least residual monomer content was found in Group 4 (0.12 wt%) followed by Group 3 (0.19 wt%), Group 2 (0.23 wt%), and Group 1 (0.26 wt%). Statistically significant difference ( P < 0.05) was found in residual monomer content for all the four groups tested. Post hoc test for intergroup comparison also showed a significant difference between groups. The amount of the residual monomer was found to be least in deep-frozen polished PMMA specimen stored in water for 24 h at +37°C (Group 4). Thus, it can be concluded that deep freezing, polishing, and storing in water can reduce the residual monomer content.
The role of questionnaires in the assessment of asthma control.
Przybyszowski, Marek; Bochenek, Grażyna
2015-01-01
The achievement and the maintenance of asthma control is currently considered the main goal of asthma treatment. Recent guidelines recommend regular assessment of asthma control and indicate questionnaires as important tools that can facilitate its evaluation. Questionnaires relate to GINA or NAEPP guidelines. Questionnaires constitute complex numerical or categorical scales and consist of several to over a dozen questions relating to the patient's symptoms of asthma, limitations in daily activities and usage of rescue medications within a period of time. Each questionnaire is characterized by the features that affect its reliability and usefulness. In the following paper we discuss most of the questionnaires which assess asthma control. We focus on the items they include and present the results of studies that prove the effectiveness of individual questionnaires in assessment of asthma control. Attention was drawn to the patient groups to which the questionnaires are addressed. We list the features of the questionnaire which should be considered before choosing a test, so that it satisfies both the doctor's and the patient's needs. The role of questionnaires as the easy-to-use tools is growing steadily. Unfortunately, not all are available in Polish language. Conducting appropriate validation studies may allow to use many of them in Polish conditions.
Rao, Duggineni Chalapathi; Kalavathy, N; Mohammad, H S; Hariprasad, A; Kumar, C Ravi
2015-01-01
Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.
Effects of chemo-mechanical polishing on CdZnTe X-ray and gamma-ray detectors
Egarievwe, Stephen E.; Hossain, Anwar; Okwechime, Ifechukwude O.; ...
2015-06-23
Here, mechanically polishing cadmium zinc telluride (CdZnTe) wafers for x-ray and gamma-ray detectors often is inadequate in removing surface defects caused by cutting them from the ingots. Fabrication-induced defects, such as surface roughness, dangling bonds, and nonstoichiometric surfaces, often are reduced through polishing and etching the surface. In our earlier studies of mechanical polishing with alumina powder, etching with hydrogen bromide in hydrogen peroxide solution, and chemomechanical polishing with bromine–methanol–ethylene glycol solution, we found that the chemomechanical polishing process produced the least surface leakage current. In this research, we focused on using two chemicals to chemomechanically polish CdZnTe wafers aftermore » mechanical polishing, viz. bromine–methanol–ethylene glycol (BME) solution, and hydrogen bromide (HBr) in a hydrogen peroxide and ethylene–glycol solution. We used x-ray photoelectron spectroscopy (XPS), current–voltage (I–V) measurements, and Am-241 spectral response measurements to characterize and compare the effects of each solution. The results show that the HBr-based solution produced lower leakage current than the BME solution. Results from using the same chemomechanical polishing solution on two samples confirmed that the surface treatment affects the measured bulk current (a combination of bulk and surface currents). XPS results indicate that the tellurium oxide to tellurium peak ratios for the mechanical polishing process were reduced significantly by chemomechanical polishing using the BME solution (78.9% for Te 3d 5/2O 2 and 76.7% for Te 3d 3/2O 2) compared with the HBr-based solution (27.6% for Te 3d 5/2O 2 and 35.8% for Te 3d 3/2O 2). Spectral response measurements showed that the 59.5-keV peak of Am-241 remained under the same channel number for all three CdZnTe samples. While the BME-based solution gave a better performance of 7.15% full-width at half-maximum (FWHM) compared with 7.59% FWHM for the HBr-based solution, the latter showed a smaller variation in performance of 0.39% FWHM over 7 days compared with 0.69% for the BME-based solution.« less
Meningococcal Infections - Multiple Languages
... Pohnpeian (Mahsen en Pohnpei) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Samoan (Gagana Samoa) Somali ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...
Meningitis - Multiple Languages
... Pohnpeian (Mahsen en Pohnpei) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Samoan (Gagana Samoa) Somali ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...
[Fifty years of the Polish School of Medicine at the University of Edinburgh (1941-1991)].
Tomaszewski, W
1994-01-01
The Polish School of Medicine at the University of Edinburgh started in 1941 on the initiative of the University. It was destined for soldier-students in the Polish Forces in Great Britain. This academic institution, unique in the history of universities, was a joint Scottish-Polish enterprise. An Agreement was concluded between the Polish Government in London and the University of Edinburgh. The School was an independent Polish academic institution and, at the same time, an integral part of the University of Edinburgh. The students matriculated at the University. The University provided all the laboratory and clinical facilities necessary for teaching. Due to a lack of Polish professors for some chairs a few of them were held by Scottish professors. Attached to them were Polish lecturers but the examinations were then held in English. The diploma, originally valid only in Poland, became recognised in Great Britain following an Act of Parliament in 1947. There were 337 students, a number of them women. 227 obtained the degree M.B., Ch.B. The war ended in 1945. The School continued up till 1949. Poland was not free. The Nazi occupation of Poland was replaced by Soviet domination which was to last for over 40 years. Only 22 of the graduates returned home, about 100 settled in G. Britain, another 100 dispersed world wide. The "magnanimous gesture" of the University of Edinburgh was thereafter remembered with gratitude by the members of the Polish School. In 1961, on the occasion of the 20th anniversary of the School, the first reunion of the graduates was organised in Birmingham for those settled in Gr. Britain. The success of the reunion prompted decision on organising annual "English" gatherings of the Polish graduates in Gr. Britain. The first world reunion of the graduates took place in Edinburgh in 1966, attracting a large number of participants on this occasion of the 25th anniversary of the School. That immensely successful anniversary of the Polish School which was celebrated by the University, influenced the participants to organise regular quinquennial world reunions in Edinburgh. A later, particularly memorable event, was the world reunion in 1976 on the occasion of the 250th anniversary of the Medical Faculty of the University; it was celebrated jointly, as it coincided with the 35th anniversary of the Polish School. The 45th anniversary of the School in 1986 was marked by the opening of the "Polish School of Medicine Historical Collection" in the Polish Room of the Erskine Medical Library of the University of Edinburgh. Also a Polish School of Medicine Memorial Fund, founded on contributions from the graduates, was inaugurated at the University of Edinburgh to provide scholarships for research workers from Poland. Another venture was the "Professor Antoni Jurasz Lectureship" for professors of the Edinburgh Medical Faculty to promote contact with Medical Schools in Poland by delivering lectures. An ardent desire was expressed by the original organisers of the School to continue into the future the academic links in medicine between the University and Poland. Political and ideological factors which devided the post-war Europe did not favor such a fulfillment of this plan. The members of the School who remained in the West, maintained links with the University and prepared funds to put the plans of co-operation into action. With the end of the political division of Europe the future of a productive Scottish-Polish collaboration can be viewed with hope and confidence.
Polishers around the globe: an overview on the market of large astronomical mirrors
NASA Astrophysics Data System (ADS)
Döhring, Thorsten
2014-07-01
Astronomical mirrors are key elements in modern optical telescopes, their dimensions are usually large and their specifications are demanding. Only a limited number of skilled companies respectively institutions around the world are able to master the challenge to polish an individual astronomical mirror, especially in dimensions above one meter. This paper presents an overview on the corresponding market including a listing of polishers around the globe. Therefore valuable information is provided to the astronomical community: Polishers may use the information as a global competitor database, astronomers and project managers may get more transparency on potential suppliers, and suppliers of polishing equipment may learn about unknown potential customers in other parts of the world. An evaluation of the historical market demand on large monolithic astronomical mirrors is presented. It concluded that this is still a niche market with a typical mean rate of 1-2 mirrors per year. Polishing of such mirrors is an enabling technology with impact on the development of technical know-how, public relation, visibility and reputation of the supplier. Within a corresponding technical discussion different polishing technologies are described. In addition it is demonstrated that strategic aspects and political considerations are influencing the selection of the optical finisher.
Jiang, Hong; Lv, Da; Liu, Kailei; Zhang, Weisheng; Yao, Yao; Liao, Chuhong
2014-05-01
To compare the surface roughness of nanofilled dental composite resin and microhybrid composite resins after curing and polishing. A nanofilled composite (Z350) and 4 microhybrid composites (P60, Z250, Spectrum, and AP-X) were fabricated from the lateral to the medial layers to prepare 8 mm×8 mm×5 mm cubical specimens. The 4 lateral surfaces of each specimens were polished with abrasive disks (Super-Snap). Profilometer was used to test the mean surface roughness (Ra) after polishing. P60 had the lowest Ra (0.125∓0.030 µm) followed by Z250 and Spectrum. The Ra of Z350 (0.205∓0.052 µm) was greater than that of the other 3 resins, and AP-X had the roughest surfaces. Under scanning electron microscope, the polished faces of P60 resin were characterized by minor, evenly distributed particles with fewer scratches; the polished faces of Z350 presented with scratches where defects of the filling material could be seen. The nanofilled composite Z350 has smooth surface after polishing by abrasive disks, but its smoothness remains inferior to that of other micro-hybrid composite resins.
NASA Astrophysics Data System (ADS)
Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo
2015-04-01
Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.
Regional ionospheric model for improvement of navigation position with EGNOS
NASA Astrophysics Data System (ADS)
Swiatek, Anna; Tomasik, Lukasz; Jaworski, Leszek
The problem of insufficient accuracy of EGNOS correction for the territory of Poland, located at the edge of EGNOS range is well known. The EEI PECS project (EGNOS EUPOS Integration) assumed improving the EGNOS correction by using the GPS observations from Polish ASG-EUPOS stations. A ionospheric delay parameter is a part of EGNOS correction. The comparative analysis of TEC values obtained from EGNOS and regional permanent GNSS stations showed the systematic shift. The TEC from EGNOS correction is underestimated related to computed regional TEC value. The new-‘improved’ corrections computed based on regional model were substituted for the EGNOS correction for suitable message. Dynamic measurements managed using the Mobile GPS Laboratory (MGL), showed the improvement of navigation position with TEC regional model.
Mechanized Polishing of Optical Rod and Fiber Ends
NASA Technical Reports Server (NTRS)
Gum, J. S.
1987-01-01
Workpiece holder for standard grinding and polishing machine makes it easier to produce optical finish and shape on end of metal or glass rod or bundle of optical fibers. Previously, glass parts lapped and polished manually, time-consuming procedure calling for considerable skill.
POLISHING EFFLUENT FROM A PERCHLORATE-REDUCING ANAEROBIC BIOLOGICAL CONTACTOR
The U.S. Environmental Protection Agency undertook at 3 ½ year pilot-scale biological perchlorate treatment study that included two long (311 and 340 days) examinations of anaerobic effluent polishing. The polishing system consisted of hydrogen peroxide addition and aeration, fo...
Rediscovery of Polish meteorites
NASA Astrophysics Data System (ADS)
Tymiński, Z.; Stolarz, M.; Żołądek, P.; Wiśniewski, M.; Olech, A.
2016-01-01
The total number of Polish registered meteorites (by July 2016) including the meteoritical artifacts as Czestochowa Raków I and II is 22. Most of them are described by the pioneer of Polish Meteoritics Jerzy Pokrzywnicki who also identified the meteorite fall locations. In recent years prospectors found impressive specimens of known Polish meteorites such as Morasko: 34 kg, 50 kg, 164 kg, 174 kg and 261 kg or Pultusk: 1578 g, 1576 g, 1510 g, 610 g and 580 g expanding and determining precisely the known meteorite strewn fields.
Steinebach, Fabian; Müller-Späth, Thomas; Morbidelli, Massimo
2016-09-01
The economic advantages of continuous processing of biopharmaceuticals, which include smaller equipment and faster, efficient processes, have increased interest in this technology over the past decade. Continuous processes can also improve quality assurance and enable greater controllability, consistent with the quality initiatives of the FDA. Here, we discuss different continuous multi-column chromatography processes. Differences in the capture and polishing steps result in two different types of continuous processes that employ counter-current column movement. Continuous-capture processes are associated with increased productivity per cycle and decreased buffer consumption, whereas the typical purity-yield trade-off of classical batch chromatography can be surmounted by continuous processes for polishing applications. In the context of continuous manufacturing, different but complementary chromatographic columns or devices are typically combined to improve overall process performance and avoid unnecessary product storage. In the following, these various processes, their performances compared with batch processing and resulting product quality are discussed based on a review of the literature. Based on various examples of applications, primarily monoclonal antibody production processes, conclusions are drawn about the future of these continuous-manufacturing technologies. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gramaglia, C; Brytek-Matera, A; Rogoza, R; Zeppegno, P
2017-02-21
Orthorexia nervosa (ON) is defined as pathological healthful eating. The aim of this study was to investigate whether there is any difference in orthorexic behaviours between clinical and non-clinical groups, and in different cultural contexts. . Recruitment involved both female patients with anorexia nervosa (AN) and healthy controls (HC) from Italy and Poland (N = 23 and N = 35 AN patients; and N = 39 and N = 39 HCs, in Italy and Poland, respectively). Assessment of orthorexic behaviours was performed with the ORTO-15 test. Statistically significant differences were found between Italian women in the AN and HC group, whereas no difference between Polish women in the AN and HC group was found. Both Italian groups scored significantly higher than the Polish ones on the ORTO-15. Differences have been found between the Italian and Polish samples, both in the percentage of individuals with orthorexic behaviours as suggested by an ORTO 15 score below the cutoff, and in the mean ORTO 15 scores in the AN and HC groups, suggesting cross-cultural differences in orthorexic behaviours, whose meaning is currently difficult to understand.
NASA Astrophysics Data System (ADS)
Hooper, Abigail R.; Boffa, Christopher C.; Sarkas, Harry W.; Cureton, Kevin
2015-08-01
When building an optical system, optical fabricators and designers meticulously choose the glass types for their application knowing that each one will have different chemical, thermal and mechanical properties. As the requirements for new optical systems have grown more demanding, the range of available glass types has vastly expanded and the specifications on the produced products have grown tighter. In an attempt to simplify processes and streamline consumable purchases, optical polishing houses often rely on one polishing slurry to manage these vast array of glass types. An unforeseen consequence of these practices can be a reduction in productivity by reduced removal rate, poor yields and frequent rework all translating into higher costs and reduced profitability. In this paper, the authors will examine the impact slurry pH has on glass types of different compositions and chemical, thermal and mechanical properties when using a double-sided polishing process. Experiments will use material removal rate, surface quality, and surface figure to provide insight into improving process control for differing glass types. Further guidance will be provided on how simple on-site monitoring and adjustment can deliver improved profitability on challenging substrates.
Zhang, Yifan; Dai, Yifan; Tie, Guipeng; Hu, Hao
2016-10-10
As a kind of important nonlinear optical element, KDP crystal has great demand in the inertial confinement fusion system. Based on the dissolution mechanism of solid materials, the factors that affect the material removal rate of KDP crystal in magnetorheological (MR) water-dissolution polishing are investigated to improve the machining efficiency. It is found that the material removal rate is proportional to the product of the saturation concentration and diffusion coefficient, and the relationship between the removal efficiency and the temperature meets the unilateral Gaussian function. Polishing experiments are carried out on a magnetorheological finishing (MRF) machine with self-designed MRF fluid heating devices. The experimental results show that practical efficiency-temperature curve is consistent with the theoretical curve, and the maximum machining efficiency increases by about 50% with the rise of temperature from 294 to 302 K. Meanwhile, when the MR fluid temperature is lower than 308 K, the crystal surface quality and surface roughness in different processing temperatures have no remarkable difference with constant crystal temperature (294 K). This research indicates that it is feasible to drastically improve KDP crystal MRF efficiency by controlling the processing temperature.
Yap, Adrian U J; Yap, W Y; Yeo, Egwin J C; Tan, Jane W S; Ong, Debbie S B
2003-01-01
This study investigated the effect of finishing/polishing techniques on the microleakage of resin-modified glass ionomer restorations. Class V preparations were made on the buccal and lingual/palatal surfaces of freshly extracted teeth. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]) according to manufacturers' instructions. Immediately after light-polymerization, gross finishing was done with eight-fluted tungsten carbide burs. The teeth were then randomly divided into four groups and finishing/polishing was done with one of the following systems: (a) Robot Carbides (RC); (b) Super-Snap system (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each material-finishing/polishing system combination was eight. After finishing/polishing, the teeth were stored in distilled water at 37 degrees C for one week. The root apices were then sealed with acrylic and two coats of varnish was applied 1 mm beyond the restoration margins. The teeth were subsequently subjected to dye penetration testing (0.5% basic fuchsin), sectioned and scored. Data was analyzed using Kruskal-Wallis and Mann-Whitney U tests at a significance level of 0.05. Results of statistical analysis were as follows: Enamel margins: PF-OG
NASA Astrophysics Data System (ADS)
Jacobs, Stephen D.
2011-10-01
Deterministic final polishing of high precision optics using sub-aperture processing with magnetorheological finishing (MRF) is an accepted practice throughout the world. A wide variety of materials can be successfully worked with aqueous (pH 10), magnetorheological (MR) fluids, using magnetic carbonyl iron (CI) and either ceria or nanodiamond nonmagnetic abrasives. Polycrystalline materials like zinc sulfide (ZnS) and zinc selenide (ZnSe) are difficult to polish at pH 10 with MRF, due to their grain size and the relatively low stiffness of the MR fluid lap. If microns of material are removed, the grain structure of the material begins to appear. In 2005, Kozhinova et al. (Appl. Opt. 44 4671-4677) demonstrated that lowering pH could improve MRF of ZnS. However, magnetic CI particle corrosion rendered their low pH approach unstable and unsuitable for commercial implementation. In 2009, Shafrir et al. described a sol-gel coating process for manufacturing a zirconia-coated CI particle that protects the magnetic core from aqueous corrosion (Appl. Opt .48 6797-6810). The coating process produces free nanozirconia polishing abrasives during the coating procedure, thereby creating an MR polishing powder that is "self-charged" with the polishing abrasive. By simply adding water, it was possible to polish optical glasses and ceramics with good stability at pH 8 for three weeks. The development of a corrosion resistant, MR polishing powder, opens up the possibility for polishing additional materials, wherein the pH may be adjusted to optimize effectiveness. In this paper we describe the CI coating process, the characterization of the coated powder, and procedures for making stable MR fluids with adjustable pH, giving polishing results for a variety of optical glasses and crystalline ceramics.
High quality optically polished aluminum mirror and process for producing
NASA Technical Reports Server (NTRS)
Lyons, III, James J. (Inventor); Zaniewski, John J. (Inventor)
2005-01-01
A new technical advancement in the field of precision aluminum optics permits high quality optical polishing of aluminum monolith, which, in the field of optics, offers numerous benefits because of its machinability, lightweight, and low cost. This invention combines diamond turning and conventional polishing along with india ink, a newly adopted material, for the polishing to accomplish a significant improvement in surface precision of aluminum monolith for optical purposes. This invention guarantees the precise optical polishing of typical bare aluminum monolith to surface roughness of less than about 30 angstroms rms and preferably about 5 angstroms rms while maintaining a surface figure accuracy in terms of surface figure error of not more than one-fifteenth of wave peak-to-valley.
High quality optically polished aluminum mirror and process for producing
NASA Technical Reports Server (NTRS)
Lyons, III, James J. (Inventor); Zaniewski, John J. (Inventor)
2002-01-01
A new technical advancement in the field of precision aluminum optics permits high quality optical polishing of aluminum monolith, which, in the field of optics, offers numerous benefits because of its machinability, lightweight, and low cost. This invention combines diamond turning and conventional polishing along with india ink, a newly adopted material, for the polishing to accomplish a significant improvement in surface precision of aluminum monolith for optical purposes. This invention guarantees the precise optical polishing of typical bare aluminum monolith to surface roughness of less than about 30 angstroms rms and preferably about 5 angstroms rms while maintaining a surface figure accuracy in terms of surface figure error of not more than one-fifteenth of wave peak-to-valley.
Polish-made payload for the BRITE-PL 2 satellite Heweliusz
NASA Astrophysics Data System (ADS)
Zawistowski, Tomasz
2012-05-01
Two institutes of the Polish Academy of Sciences, Space Research Centre and Nicolaus Copernicus Astronomical Center cooperate on the project to build and place in orbit the first Polish scientific satellite. The BRITE (BRight Target Explorer) mission formed by Austria, Canada and Poland will send to space a constellation of six nanosatelites, two from each country. They will be observing star pulsations with fotometric methods gathering data that will verify thermodynamic models of bright, massive stars of our Galaxy, delivering information on their structure, formation and evolution. The first of two Polish satellites, "LEM", will closely resemble its international kin, while the second, "Heweliusz" will carry Polish flavor to space - delivering additional technological experiments. They will use commercial-off-the-shelf components.
Ultra-low roughness magneto-rheological finishing for EUV mask substrates
NASA Astrophysics Data System (ADS)
Dumas, Paul; Jenkins, Richard; McFee, Chuck; Kadaksham, Arun J.; Balachandran, Dave K.; Teki, Ranganath
2013-09-01
EUV mask substrates, made of titania-doped fused silica, ideally require sub-Angstrom surface roughness, sub-30 nm flatness, and no bumps/pits larger than 1 nm in height/depth. To achieve the above specifications, substrates must undergo iterative global and local polishing processes. Magnetorheological finishing (MRF) is a local polishing technique which can accurately and deterministically correct substrate figure, but typically results in a higher surface roughness than the current requirements for EUV substrates. We describe a new super-fine MRF® polishing fluid whichis able to meet both flatness and roughness specifications for EUV mask blanks. This eases the burden on the subsequent global polishing process by decreasing the polishing time, and hence the defectivity and extent of figure distortion.
Searching the Polish Medical Bibliography (Polska Bibliografia Lekarska) for trials.
Almerie, Muhammad Qutayba; Matar, Hosam El-Din; Jones, Vicki; Kumar, Ajit; Wright, Judith; Wlostowska, Ewa; Adams, Clive E
2007-12-01
The Polish Medical Bibliography (Polska Bibliografia Lekarska) contains 350 000 records dating from 1979. These records from the fields of medicine, nursing, dentistry, health care systems and preclinical sciences are from nearly 300 biomedical journals published in Poland. We systematically searched the Polish Medical Bibliography Part II (1996-2006) CD-ROM (July 2006) using both English and Polish phrases for randomized trials, manually checked results and, for the trials identified in this way, sought these on medline and embase. Systematic searching identified records of 680 randomized trials from all areas of health care. Nearly 40% of these were not found on either medline or embase. The Polish Medical Bibliography should be of interest to health care information specialists concerned with comprehensive searches for trials.
Effects of nail polish on microbial growth of fingernails. Dispelling sacred cows.
Baumgardner, C A; Maragos, C S; Walz, J; Larson, E
1993-07-01
Nail polish worn on short, healthy nails does not appear to be associated with increased microbial counts on the fingernails. Additional studies to examine the effect of wearing nail polish on other aspects of hand hygiene may be warranted, however.
Zirconia coated carbonyl iron particle-based magnetorheological fluid for polishing
NASA Astrophysics Data System (ADS)
Shafrir, Shai N.; Romanofsky, Henry J.; Skarlinski, Michael; Wang, Mimi; Miao, Chunlin; Salzman, Sivan; Chartier, Taylor; Mici, Joni; Lambropoulos, John C.; Shen, Rui; Yang, Hong; Jacobs, Stephen D.
2009-08-01
Aqueous magnetorheological (MR) polishing fluids used in magnetorheological finishing (MRF) have a high solids concentration consisting of magnetic carbonyl iron particles and nonmagnetic polishing abrasives. The properties of MR polishing fluids are affected over time by corrosion of CI particles. Here we report on MRF spotting experiments performed on optical glasses using a zirconia coated carbonyl iron (CI) particle-based MR fluid. The zirconia coated magnetic CI particles were prepared via sol-gel synthesis in kg quantities. The coating layer was ~50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long term stability against aqueous corrosion. "Free" nano-crystalline zirconia polishing abrasives were co-generated in the coating process, resulting in an abrasivecharged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses over a period of 3 weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.
Polishing and toothbrushing alters the surface roughness and gloss of composite resins.
Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu; Kanehira, Masafumi; Finger, Werner J
2014-01-01
This study aimed to investigate the surface roughness and gloss of composite resins after using two polishing systems and toothbrushing. Six composite resins (Durafill VS, Filtek Z250, Filtek Z350 XT, Kalore, Venus Diamond, and Venus Pearl) were evaluated after polishing with two polishing systems (Sof-Lex, Venus Supra) and after toothbrushing up to 40,000 cycles. Surface roughness (Ra) and gloss were determined for each composite resin group (n=6) after silicon carbide paper grinding, polishing, and toothbrushing. Two-way ANOVA indicated significant differences in both Ra and gloss between measuring stages for the composite resins tested, except Venus Pearl, which showed significant differences only in gloss. After polishing, the Filtek Z350 XT, Kalore, and Venus Diamond showed significant increases in Ra, while all composite resin groups except the Filtek Z350 XT and Durafill VS with Sof-Lex showed increases in gloss. After toothbrushing, all composite resin demonstrated increases in Ra and decreases in gloss.
Consensus Conference Findings on Supragingival and Subgingival Air Polishing.
Cobb, Charles M; Daubert, Diane M; Davis, Karen; Deming, Jodi; Flemmig, Thomas F; Pattison, Anna; Roulet, Jean-François; Stambaugh, Roger V
2017-02-01
A consensus conference was convened to evaluate and address issues of safety and efficacy when using glycine powder in an air-powder jet device for supra- and subgingival applications during dental prophylaxis and periodontal maintenance. The conference reported the following conclusions: 1) Supra- and subgingival air polishing using glycine powder is safe and effective for removal of biofilms from natural tooth structure and restorative materials; 2) there is no evidence of soft-tissue abrasion when using glycine powder in an air-polishing device; 3) in periodontal probing depths of 1 mm to 4 mm, glycine-powder air polishing, using a standard air-polishing nozzle, is more effective at removing subgingival biofilm than manual or ultrasonic instruments; and 4) at probing depths of 5 mm to 9 mm, using a subgingival nozzle, glycine powder air polishing is more effective at removing subgingival biofilm than manual or ultrasonic instrumentation. This conference statement, supported by an industry grant, was drafted by a panel of distinguished dental professionals.
Worldwide Report, Arms Control
1986-02-28
NACHRICHTEN , 18 Oct 85) 39 Presummit Polish Reporting on SDI Issues (Warsaw RZECZPOSPOLITA, 19-20 Oct 85; Warsaw ZYCIE WARSZAWY, 15 Oct 85) 42...28 February 1986 SDI AND SPACE ARMS MEETING REVEALS SOME SUPPORT FOR EUREKA LINK TO MILITARY Puesseldbrf VDI NACHRICHTEN in German 18 Oct 85 p 10
Olofinjana, Bolutife; Lorenzo-Martin, Cinta; Ajayi, Oyelayo O.; ...
2015-06-06
Surface texturing or topographical design is one of the primary techniques to control friction and wear performance of surfaces in tribological contact. Laser surface texturing (LST), whereby a laser beam is used to produce regular arrays of dimples on a surface, has been demonstrated to reduce friction in conformal lubricated contacts. Friction and wear behavior under boundary lubrication is also known to be dependent on the formation and durability of the tribochemical film formed from lubricant additives. In this paper, the effects of LST on the formation and durability of tribochemical films and its consequent impacts on friction and wearmore » behavior in various lubrication regimes were evaluated. Friction and wear tests that cycled through different lubrication regimes were conducted with both polished and LST treated surfaces using a synthetic lubricant with and without model additives of ZDDP and MoDTC mixture. In the base oil without additives, LST produced noticeable reduction in friction in all lubrication regimes. However, with low-friction model additives, friction was higher in tests with LST due to significant differences in the tribochemical film formation in the polished and LST surfaces, as well as the sliding counterface. Continuous tribo-films were formed on ball conterface rubbed against polished surfaces while the films were streaky and discontinuous in ball rubbed against LST surfaces. LST produced more wear on the ball counterface in both base and additized oils. Lastly, no measurable wear was observed in both the polished and LST flat specimens.« less
Ciurzyński, Michał; Kurzyna, Marcin; Kopeć, Grzegorz; Błaszczak, Piotr; Chrzanowski, Łukasz; Kamiński, Karol; Mizia-Stec, Katarzyna; Mularek-Kubzdela, Tatiana; Mroczek, Ewa; Biederman, Andrzej; Pruszczyk, Piotr; Torbicki, Adam
2017-01-01
Both pharmacological and invasive treatment of chronic thromboembolic pulmonary hypertension (CTEPH) is now available in Poland and the awareness of the disease among physicians is growing. Thus, the Polish Cardiac Society's Working Group on Pulmonary Circulation in cooperation with independent experts in this field, have launched the statement on algorithm to guide a CTEPH diagnosis in patients with previous acute pulmonary embolism (APE). In Poland, every year this disease affects about 250 patients. CTEPH should be suspected in individuals after APE with dyspnea, despite at least 3 months period of effective anticoagulation, particularly when specified risk factors are present. Echocardiography is a main screening tool. The authors suggest that a diagnostic process of patients with significant clinical suspicion of CTEPH and right ventricle overload in echocardiography should be performed in reference centres. The document contains a list of Polish centres diagnosing patients with suspected CTEPH. Pulmonary scintigraphy is a safe and highly sensitive screening test for CTEPH. Multi-detector computed tomography with precise detection of thromboembolic residues in pulmonary circulation is important for planning of pulmonary endarterectomy. Right heart catheterisation definitely confirms the presence of pulmonary hypertension and direct pulmonary angiography allows for identification of lesions suitable for thromboendarterectomy or pulmonary balloon angioplasty. In this document a diagnostic algorithm in patients with suspected CTEPH is also proposed. With individualised sequential diagnostic strategy each patient can be finally qualified for a particular mode of therapy by dedicated CTEPH Heart Team. Moreover the document contains short information for the primary care physician about the management of patients after APE.
Sudha, Vasudevan; Spiegelman, Donna; Hong, Biling; Malik, Vasanti; Jones, Clara; Wedick, Nicole M; Hu, Frank B; Willett, Walter; Bai, Mookambika Ramya; Ponnalagu, Muthu Mariyammal; Arumugam, Kokila; Mohan, Viswanathan
2013-01-01
To study consumer acceptance of unmilled brown and undermilled rice among urban south Indians. Overweight and normal weight adults living in slum and nonslum residences in Chennai participated (n = 82). Bapatla (BPT) and Uma (red pigmented) rice varieties were chosen. These rice varieties were dehusked (unmilled, 0% polish) and further milled to 2.3% and 4.4% polishing (undermilled). Thus, 9 rice samples in both raw and parboiled forms were provided for consumer tasting over a period of 3 days. A 7-point hedonic scale was used to rate consumer preferences. A validated questionnaire was used to collect demographic, anthropometric, medical history, physical activity, dietary intake data, and willingness of the consumers to switch over to brown rice. Consumers reported that the color, appearance, texture, taste, and overall quality of the 4.4% polished rice was strongly preferred in both varieties and forms. Ratings for 0% polished (brown rice) were substantially lower than those of 2.3% polished rice, which were intermediate in ratings between 0% and 4.4% polishing. However, most of the consumers (93%) expressed a willingness to substitute brown or 2.3% polished rice, if affordable, after the taste tests and education on nutritional and health benefits of whole grains. Though most consumers preferred polished white rice, education regarding health benefits may help this population switch to brown or undermilled rice. Cooking quality and appearance of the grains were perceived as the most important factors to consider when purchasing rice among Chennai urban adults.
1991-09-11
signal did not vary on side B when the laser beam was incident on different regions of the surface. The absorption was the same when examining a...silica and zerodur I have been polished using this technique. Float polished substrates have a typical surface roughness of approximately 2 A, with a
ERIC Educational Resources Information Center
Defense Language Inst., Washington, DC.
These 15 volumes of the Basic Polish Course, prepared for use in the Defense Language Institute's intensive language program, comprise Lessons 1-124. They are disigned to train native English language speakers to Level 3 proficiency in comprehension, speaking, reading, and writing Polish. (Level 5 is native-speaker fluency.) The phonological…
Section of Cybernetics in Mining of Mining Committee of Polish Academy of Sciences - Pro Memoria
NASA Astrophysics Data System (ADS)
Wojaczek, Antoni; Miśkiewicz, Kazimierz
2017-09-01
Section of Cybernetics in Mining of Mining Committee of Polish Academy of Science (PAN) has been created by PAN Mining Committee in 1969. It was a section in Mining Committee of PAN, whose operation range included widely understood issues of automation, telecommunication and informatics in mining industry. The main operation method of the Section was to organize the periodic conferences dedicated to issues of control systems in mining. The first conference took place in 1971 in Katowice. Together with new (the current one) term of office of Mining Committee of PAN this Section ceased to exist. The paper presents (pro memoria) over 40 year long conference output of this Section that functioned within the scope of operation of Mining Committee of PAN up to 12th January 2016.
NASA Technical Reports Server (NTRS)
1994-01-01
Lewis Research Center (LEW) has assisted The Cleveland Museum of Art (CMA) in analyzing the museum's paintings. Because of the many layers of paint that are often involved, this is a complex process. The cross-section of a paint chip must be scanned with a microscope to determine whether a paint layer is original or a restoration. The paint samples, however, are rarely flat enough for high magnification viewing and are frequently scratched. LEW devised an automated method that produces intact, flat, polished paint cross-sections. A sophisticated microprocessor-controlled grinding and polishing machine was manually employed in preparation of exotic samples for aerospace research was a readily adaptable technique. It produced perfectly flat samples with clearly defined layers. The process has been used successfully on a number of paintings, and LEW and CMA are considering additional applications.
From the History of Conferences on the Machine and Mechanism Science
NASA Astrophysics Data System (ADS)
Wojnarowski, J.
2016-08-01
In the course of the past sixty years of the Polish Committee for the Theory of Machines and Mechanisms (PC TMM) 24 scientific and didactic conferences have been held. The subject matter of these conferences, generally organized every other year, comprised problems of the classification, analysis and synthesis of mechanisms, the dynamics of machine systems, investigations concerning self-excited vibrations, the stability of the systems, the control of machines and biomechanics. The numbers of submitted papers as well as the number of participants substantiate the need of organizing such conferences, their importance and the activity of the Polish Committee of TMM for the purpose of creating a platform for the presentation and discussion of new research methods in the domain of mechanisms, machines, biomechanics and mechatronics.
Polish Americans. Second, Revised Edition.
ERIC Educational Resources Information Center
Lopata, Helen Znaniecka
This book examines Polonia, the Polish ethnic community in America created by three giant waves of immigration between 1880 and 1990. The complicated history of this ethnic group is reflected in the lives of increasing numbers of Polish Americans, including recent immigrants brought by political and economic changes, as they achieve middle class…
This abstract describes a pilot-scale evaluation of anaerobic biological perchlorate (C1O4) removal followed by aerobic effluent polishing. The anaerobic biological contactor operated for 3.5 years. During that period, two effluent polishing evaluations, lasting 311 an...
This abstract describes a pilot-scale evaluation of anaerobic biological perchlorate (C1O4) removal followed by aerobic effluent polishing. The anaerobic biological contactor operated for 3.5 years. During that period, two effluent polishing evaluations, lasting 311 an...
Takizawa, Ken; Beaucamp, Anthony
2017-09-18
A new category of circular pseudo-random paths is proposed in order to suppress repetitive patterns and improve surface waviness on ultra-precision polished surfaces. Random paths in prior research had many corners, therefore deceleration of the polishing tool affected the surface waviness. The new random path can suppress velocity changes of the polishing tool and thus restrict degradation of the surface waviness, making it suitable for applications with stringent mid-spatial-frequency requirements such as photomask blanks for EUV lithography.
Evaluating a vessel for suitability for containing fluid
Barefield, II, James E.; Judge, Elizabeth J.; Le, Loan A.; Lopez, Leon N.; Beveridge, Andrew C.; Chapman, Daniel R.; Taylor, Seth T.
2017-05-30
A method for evaluating a vessel for suitability to contain a fluid includes providing a vessel and forming a polished surface portion of the vessel by removing oxidation and/or contaminants from a portion of the vessel. The method further includes applying a focused laser to the polished surface portion to form plasma on the polished surface portion, and determining whether the vessel is suitable for containing a fluid based on silicon content of the polished surface portion. The silicon content is estimated based on light emitted from the plasma.
NASA Astrophysics Data System (ADS)
Jianxiu, Su; Xiqu, Chen; Jiaxi, Du; Renke, Kang
2010-05-01
Distribution forms of abrasives in the chemical mechanical polishing (CMP) process are analyzed based on experimental results. Then the relationships between the wafer, the abrasive and the polishing pad are analyzed based on kinematics and contact mechanics. According to the track length of abrasives on the wafer surface, the relationships between the material removal rate and the polishing velocity are obtained. The analysis results are in accord with the experimental results. The conclusion provides a theoretical guide for further understanding the material removal mechanism of wafers in CMP.
Reel-to-reel substrate tape polishing system
Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei
2005-06-21
Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.
Improvement of magnetorheological finishing surface quality by nanoparticle jet polishing
NASA Astrophysics Data System (ADS)
Peng, Wenqiang; Li, Shengyi; Guan, Chaoliang; Shen, Xinmin; Dai, Yifan; Wang, Zhuo
2013-04-01
Nanoparticle jet polishing (NJP) is presented as a posttreatment to remove magnetorheological finishing (MRF) marks. In the NJP process the material is removed by chemical impact reaction, and the material removal rate of convex part is larger than that of the concave part. Smoothing thus can progress automatically in the NJP process. In the experiment, a silica glass sample polished by MRF was polished by NJP. Experiment results showed the MRF marks were removed clearly. The uniform polishing process shows that the NJP process can remove the MRF marks without destroying the original surface figure. The surface root-mean-square roughness is improved from 0.72 to 0.41 nm. power spectral density analysis indicates the surface quality is improved, and the experimental result validates effective removal of MRF marks by NJP.
Syroka, Bozena Płonka
2006-01-01
The issue of presence of doctors of Jewish origin in Polish medical community is the subject of research presented in this article. The author describes the most important personalities originating from this national group, who had the biggest contribution to Polish modern times medical life. The process of Jewish minority assimilation to Polish culture in 18th and 19th centuries is outlined, as well as its effects in reborn Poland. Also, the Jewish minority situation during the Second World War is describes, and the harm they suffered then. Against this background the author shows the anti-Semitic trends visible in Polish political life in times of Polish People's Republic, especially during the 1968 upheavals, which greatly contributed to the fact that many doctors of medicine of Jewish origin emigrated from Poland for political reasons.
Sierpińska, Lidia
2013-09-01
The Authentic Leadership Questionnaire (ALQ) is a standardized research instrument for the evaluation of individual elements of leader's conduct which contribute to the authentic leadership. The application of this questionnaire in Polish conditions required to carry out the validation process. The aim of the study was to evaluate of validity and reliability of the Polish version of the American research instrument for the needs of evaluation of authenticity of leadership of the nursing management in Polish hospitals. The study covered 286 nurses (143 head nurses and 143 of their subordinates) employed in 45 hospitals in Poland. Theoretical validity of the instrument was evaluated using Fisher's transformation (r-Person correlation coefficient), while the criterion validity of the ALQ was evaluated using rho-Spearman correlation coefficient and the BOHIPSZO questionnaire. The reliability of the ALQ was assessed by means of the Cronbach-alpha coefficient. The ALQ questionnaire applied for the evaluation of authenticity of leadership of the nursing management in Polish hospital wards shows an acceptable theoretical and criterion validity and reliability (Cronbach-alpha coefficient 0.80). The Polish version of the ALQ is valid and reliable, and may be applied in studies concerning the evaluation of authenticity of leadership of the nursing management in Polish hospital wards.
Peano-like paths for subaperture polishing of optical aspherical surfaces.
Tam, Hon-Yuen; Cheng, Haobo; Dong, Zhichao
2013-05-20
Polishing can be more uniform if the polishing path provides uniform coverage of the surface. It is known that Peano paths can provide uniform coverage of planar surfaces. Peano paths also contain short path segments and turns: (1) all path segments have the same length, (2) path segments are mutually orthogonal at the turns, and (3) path segments and turns are uniformity distributed over the domain surface. These make Peano paths an attractive candidate among polishing tool paths because they enhance multidirectional approaches of the tool to each surface location. A method for constructing Peano paths for uniform coverage of aspherical surfaces is proposed in this paper. When mapped to the aspherical surface, the path also contains short path segments and turns, and the above attributes are approximately preserved. Attention is paid so that the path segments are still well distributed near the vertex of the surface. The proposed tool path was used in the polishing of a number of parabolic BK7 specimens using magnetorheological finishing (MRF) and pitch with cerium oxide. The results were rather good for optical lenses and confirm that a Peano-like path was useful for polishing, for MRF, and for pitch polishing. In the latter case, the surface roughness achieved was 0.91 nm according to WYKO measurement.
NASA Astrophysics Data System (ADS)
Menapace, J. A.; Ehrmann, P. R.; Bickel, R. C.
2009-10-01
Over the past year we have been working on specialized MR fluids for polishing KDP crystals. KDP is an extremely difficult material to conventionally polish due to its water solubility, low hardness, and temperature sensitivity. Today, KDP crystals are finished using single-point diamond turning (SPDT) tools and nonaqueous lubricants/coolants. KDP optics fabricated using SPDT, however, are limited to surface corrections due to tool/method characteristics with surface quality driven by microroughness from machine pitch, speed, force, and diamond tool character. MRF polishing offers a means to circumvent many of these issues since it is deterministic which makes the technique practical for surface and transmitted wavefront correction, is low force, and is temperature independent. What is lacking is a usable nonaqueous MR fluid that is chemically and physically compatible with KDP which can be used for polishing and subsequently cleaned from the optical surface. In this study, we will present the fluid parameters important in the design and development of nonaqueous MR fluid formulations capable of polishing KDP and how these parameters affect MRF polishing. We will also discuss requirements peculiar to successful KDP polishing and how they affect optical figure/finish and laser damage performance at 1064 nm and 532 nm.
USDA-ARS?s Scientific Manuscript database
Importance: Infantile beriberi, a potentially fatal disease caused by thiamin deficiency, remains a public health concern in Cambodia and regions where B-vitamin poor, polished white rice is a staple food. Low maternal thiamin intake reduces breast milk thiamin concentrations, placing breastfed infa...
1990-01-23
PM0512141589 Gdansk DZIENNIK BALTYCKI in Polish 17 Nov 89 p 3 [Interview with Navy Commander Vice Admiral Piotr Kolodziejczyk by Adam Schmidt—date... Brzezinski , the former U.S. presidential adviser, had to say: "Poland is situated here and not in the West, and this is something that is also of
... Oromoo) Pashto (Pax̌tō / پښتو ) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Somali (Af-Soomaali ) Spanish ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...
Muthukrishnan, Thirumahal; Dobretsov, Sergey; De Stefano, Mario; Abed, Raeid M M; Kidd, Barry; Finnie, Alistair A
2017-08-01
Little is known about the effect of commercial biocidal fouling control coatings on fouling diatom communities and their growth forms after long periods of exposure in the marine tropical environment. The current study investigated the abundance and composition of fouling diatom communities developed on 11 commercially available biocidal antifouling coatings, covering the three main technology types in recent historic use (Self-Polishing Copolymers, Self-Polishing Hybrid and Controlled Depletion Polymers) after one year of static immersion at two locations in Muscat, Oman (Marina Shangri La and Marina Bandar Rowdha). Light microscopy demonstrated that the total abundance of diatoms and the relative abundance of growth forms were significantly affected by the choice of biocidal antifouling coating and experimental location. Using scanning electron microscopy, a total of 21 diatom genera were identified which were grouped into adnate, motile, plocon and erect growth forms. The adnate growth forms, mainly the genera Amphora, Cocconeis and Mastogloia, dominated the other growth forms in terms of their relative abundance. Current results revealed the importance of exposure location and choice of biocidal antifouling coating on the relative abundance of diatom growth forms. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wasilewska, Marta
2017-10-01
This paper presents the comparison of skid resistance of wearing course made of SMA (Stone Mastic Asphalt) mixtures which differ in resistance to polishing of coarse aggregate. Dolomite, limestone, granite and trachybasalt were taken for investigation. SMA mixtures have the same nominal size of aggregate (11 mm) and very similar aggregate particle-size distribution in mineral mixtures. Tested SMA11 mixtures were designed according to EN 13108-5 and Polish National Specification WT-2: 2014. Evaluation of the skid resistance has been performed using the FAP (Friction After Polishing) test equipment also known as the Wehner/Schulze machine. Laboratory method enables to compare the skid resistance of different types of mixtures under specified conditions simulating polishing processes. Tests were performed on both the specimens made of each coarse aggregate and SMA11 mixtures containing these aggregates. Measuring of friction coefficient μm was conducted before and during polishing process up to 180 0000 passes of polishing head. Comparison of the results showed differences in sensitivity to polishing among particular mixtures which depend on the petrographic properties of rock used to produce aggregate. Limestone and dolomite tend to have a fairly uniform texture with low hardness which makes these rock types susceptible to rapid polishing. This caused lower coefficient of friction for SMA11 mixtures with limestone and dolomite in comparison with other test mixtures. These significant differences were already registered at the beginning of the polishing process. Limestone aggregate had lower value of μm before starting the process than trachybasalt and granite aggregate after its completion. Despite the differences in structure and mineralogical composition between the granite and trachybasalt, slightly different values of the friction coefficient at the end of polishing were obtained. Images of the surface were taken with the optical microscope for better understanding of the phenomena occurring on the surface of specimen. Results may be valuable information when selecting aggregate to asphalt mixtures at the stage of its design and maintenance of existing road pavements.
Sensory factors affecting female consumers' acceptability of nail polish.
Sun, C; Koppel, K; Adhikari, K
2015-12-01
The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different sensory attributes, could help a nail polish manufacturer modify or improve their nail polish formulas. Nail polish manufacturers could use the consumer cluster information to improve their marketing strategies for specific categories of their products and to target their advertising on particular consumer groups. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
NASA Technical Reports Server (NTRS)
Chan, Q. H. S.; Zolensky, M. E.
2015-01-01
We have previously observed the magnetite plaquettes in carbonaceous chondrites using scanning electron microscope (SEM) imaging, examined the crystal orientation of the polished surfaces of magnetite plaquettes in CI Orgueil using electron backscattered diffraction (EBSD) analysis, and concluded that these magnetite plaquettes are likely naturally asymmetric materials. In this study, we expanded our EBSD observation to other magnetite plaquettes in Orgueil, and further examined the internal structure of these remarkable crystals with the use of X-ray computed microtomography.
NASA Astrophysics Data System (ADS)
Kuska, Michalina; Augustyńska, Beata; Mikołajewska, Emilia; Mikołajewski, Dariusz
2017-11-01
Mobile solutions (smartphones, tablet computers, smartwatches, smartbands, gps locallzators, and associated software) become normal part of our daily activities. Thus novel part of e-commerce named m-tourism is developing rapidly. It may maximise profitability across national boundaries and make tourism easier, quicker and cheaper than before. We should be prepared to associated changes and novel economics. Aim of the article is to investigate factors associated with m-tourism experiences, and the association between use of e-services and tourism experiences and subsequent satisfaction.
Bertoldo, Carlos; Lima, Debora; Fragoso, Larissa; Ambrosano, Glaucia; Aguiar, Flavio; Lovadino, Jose
2014-01-01
The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.
Lay beliefs on Polish oncology in the evaluation of healthy individuals.
Synowiec-Piłat, Małgorzata
2017-12-23
Poland is among the countries which reported the highest rates of mortality from cancer. The health behaviours of people are influenced, among other things, by their beliefs about cancer, but their evaluation of oncological institutions and specialists seems also to be of great importance. Objectives. 1. How the respondents evaluate Polish oncology: a) the conditions of treatment in oncology hospitals, b) access to oncological medical services, c) the competence of oncologists. 2. What are the socio-cultural factors of the assessment of Polish oncology? 3. What is the influence of the grade level of the assessment of Polish oncology on the degree of fear and the knowledge about cancer? The study was carried out with a sample of 910 adult residents of Wroclaw in south-west Poland. Quota sampling was used. An interview questionnaire was used as the method. Analysis of the data showed a negative image of Polish oncology, according to the study participants: dissatisfaction with both treatment conditions and with access to medical services. Assessment of Polish oncology depends primarily on education, age and economic situation, as well as 'family history of cancer', and attitude towards doctors. The lower the rating of Polish oncology, the lower the medical knowledge, and the higher the level of fear of cancer. Negative assessment of Polish oncology perpetuates the fear of cancer in society. There is a need for constant improvement of the quality of medical oncology services, for building public trust in physicians, to fight inequalities in health, and to take into account the lay perspectives in developing strategies to combat cancer.
Buss, Tomasz; Kruk, Agnieszka; Wiśniewski, Piotr; Modlinska, Aleksandra; Janiszewska, Justyna; Lichodziejewska-Niemierko, Monika
2014-10-01
Multidimensional questionnaires estimating cancer-related fatigue (CRF) as a symptom cluster or a clinical syndrome primarily have been used and validated in English-speaking populations. However, cultural issues and language peculiarities can affect CRF assessment The main aims of this study were to evaluate the psychometric properties of the Polish version of the Multidimensional Fatigue Inventory-20 (MFI-20) and to deliver to clinicians a multidimensional tool for CRF assessment in Polish-speaking patients with cancer. After forward-backward translation procedures, the Polish version of MFI-20 was administered to 340 cancer patients. The Polish MFI-20 was appraised in terms of acceptability, reliability, and validity. Internal consistency was assessed by calculating Cronbach's alpha coefficients. Structural validity was evaluated with confirmatory factor analysis. The translated MFI-20 was well accepted; 90% of subjects fully completed the questionnaire. The overall Cronbach's alpha coefficient was 0.9, ranging from 0.57 to 0.81. All correlation coefficients among Numeric Rating Scale-fatigue, fatigue-related items from the European Organization for Research and Treatment of Cancer Quality of Life Core-30 questionnaire, and the MFI--20 were statistically significant (P < 0.001). Confirmatory factor analysis demonstrated good structural validity and revealed only three dimensions in the Polish version of the MFI-20-physical and mental fatigue as well as reduced motivation. The Polish version of the MFI-20 is well accepted by patients, reliable, and a valid instrument to assess CRF in Polish cancer patients. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Sudha, Vasudevan; Spiegelman, Donna; Hong, Biling; Malik, Vasanti; Jones, Clara; Wedick, Nicole M.; Hu, Frank B.; Willett, Walter; Bai, Mookambika Ramya; Ponnalagu, Muthu Mariyammal; Arumugam, Kokila; Mohan, Viswanathan
2013-01-01
Objectives To study consumer acceptance of unmilled brown and under milled rice among urban south Indians. Methods Overweight and normal weight adults living in slum and non-slum residences in Chennai participated (n=82). Bapatla (BPT) and Uma (red pigmented) rice varieties were chosen. These rice varieties were dehusked (unmilled, 0% polish) and further milled to 2.3% and 4.4% polishing (under milled). Thus nine rice samples in both raw and parboiled forms were provided for consumer tasting over a period of three days. A hedonic 7-point scale was used to rate the consumer preferences. A validated questionnaire was used to collect demographic, anthropometric, medical history, physical activity, dietary intake data and willingness of the consumers to switch over to brown rice. Results Consumers reported that the color, appearance, texture, taste and overall quality of the 4.4% polished rice was strongly preferred in both varieties and forms. Ratings for 0% polished (brown rice) were substantially lower than those of 2.3% polished rice, which were intermediate in ratings between 0% and 4.4% polishing. However, most of the consumers (93%) expressed willingness to substitute brown or 2.3% polished rice if affordable after the taste tests and education on nutritional and health benefits of whole grains. Conclusion While most consumers’ preferred polished white rice, education regarding health benefits may help this population switch to brown or under milled rice. Cooking quality and appearance of the grains were perceived as the most important factors to consider when purchasing rice among Chennai urban adults. PMID:24015699
Evolution of surface characteristics in material removal simulation with subaperture tools
NASA Astrophysics Data System (ADS)
Kim, Sug-Whan; Jee, Myung-Kook
2002-02-01
Over the last decade, we have witnessed that the fabrication of 200 - 2000 mm scale have received relatively little attention from the fabrication technology development, compared to those of smaller than 200 mm and of larger than 2000 mm in diameter. As a result, the optical surfaces of these scales are still predominantly completed by small optics shops where opticians apply the traditional technique for polishing. Lack of tools in aiding opticians for planning, executing and analyzing their polishing work is a root cause for long and, sometimes, unpredictable delivery and high manufacturing cost for such optical surfaces. We present the on-going development of a software simulation environment called Surface Analysis and Fabrication Environment (SAFE). It is primarily intended to increase the throughput of polishing and testing cycles by allowing opticians to simulate the resulting surface form and roughness with input polishing variables. A brief review of current polishing techniques and their target optics clarifies the need for such simulation tool. This is followed by the development targets and a preliminary simulation plan using the developmental version of SAFE. Among many polishing variables, two removal assumptions and three different types of removal functions we used for the polishing simulation presented. The simulations show that the Gaussian removal function with the proportional removal assumption resulted in the fastest, though marginal, convergence to a super-polished surface of 0.56 micron Peat- to-Valley in form accuracy and of 0.02 nanometer in surface roughness Ra. Other meaningful results and their implications are also presented.
[The profile of WISC-R scores in children with high-functioning autism].
Zielinska, Monika; Sterczynski, Radoslaw; Baginska, Aneta
2014-01-01
The aim of the study was to define the intellectual profile of Polish children suffering from autism. Our study was based on the results of previous research, mostly conducted in English-speaking countries. Although these earlier studies documented the intellectual profile of an autistic child, they also identified some discrepancies. Therefore, we decided to complement the discussion on autism with our data on intellectual functioning of autistic Polish children examined with a translated version of the intelligence test. The study followed a matching design. From among 191 children with autism and 1 400 without this diagnosis, we selected 34 pairs based on gender and age, and not differing by more than 10 points in terms of intelligence quotient. The intellectual profile of the studied children was determined with the WISC-R scale. As expected, the intellectual profile of children with autism proved more variable than that of healthy controls. Children with autism scored lower on "Comprehension" scale and (at a threshold of statistical significance) on "Object assembly" scale, and achieved higher results on "Information" and "Block design" scales. The results of our study confirmed the most typical observations from previous research conducted among an English-speaking population of autistic children. Polish autistic children did not differ significantly in terms of their quotients of verbal and non-verbal intelligence. However, the intellectual profile of autistic children showed higher variance compared to normally developing controls. Children with autism were more likely to score the lowest in the "Comprehension" subtest and the highest in the "Block design" subtest.
Dalley, B K; Seliger, W G
1980-05-01
A simple and rapid technique is described for the screening of Epon embedded organ slices for the location, isolation, and removal of small specific sites for ultrastructural study with the transmission electron microscope. This procedure consists of perfusion fixation followed by making 1 to 21/2 mm thick slices of relatively large pieces of the organs, control of the degree and evenness of the osmium staining by addition of 3% sodium iodate, and infiltration with a fluorescent dye prior to embedment in Epon. Tissue slices are embedded in wafer-shaped blocks, generally with several slices in one "wafer", and are examined in a controlled manner using a rapid form of serial surface polishing. Each level of the polished wafer is examined using an epi-illuminated fluorescence microscope, and selected sites are chosen at each level for ultrastructural study. Methods are also described for marking each selected site using a conventional slide marker, and for the removal of the selected site in the form of a small disc of Epon, after which the Epon wafer can be further serially polished and the examination continued. Areas to be thin-sectioned are removed using a core drill mounted on a model-maker's drill press. The technique is simple, does not require the destruction of remaining tissues to evaluate more critically a single small site, allows for the easy maintenance of tissue orientation, and the most time-consuming portions of the technique can be quickly taught to a person with no previous histological training.
ERIC Educational Resources Information Center
Tonakiewicz-Kolosowska, Anna; Socik, Iwona; Gajewska, Monika
2016-01-01
The authors present the development and perspectives of improving the quality of Information Literacy programmes in Polish technical universities, considering the Bologna Process and the general conditions of the Polish higher education system. The survey conducted in selected technical and medical universities provided an overview of changes…
On the Inclusive and Exclusive Functions of the "Other" Language in Family Talk
ERIC Educational Resources Information Center
Ogiermann, Eva
2013-01-01
The present study analyses bilingual conversations taking place in binational families living in the UK. The focus is on two Polish/English stepfamilies, where the Polish mothers' concern with preserving and developing their children's linguistic and cultural identity collides with the English partner's limited knowledge of Polish. While the paper…
Guide and Bibliography for Integrating Polish Studies into the Public School Curriculum.
ERIC Educational Resources Information Center
Wozniak, Albin S.
This bibliography contains citations to general and specific works on Polish Americans, their cultural and social roots, their history, literature and arts, and ethnic identity. A series of anthologies which deal with adaptation problems and the acculturation of Polish American groups are included. There are also references that provide guidelines…
Holocaust Education in Polish Public Schools: Between Remembrance and Civic Education
ERIC Educational Resources Information Center
Milerski, Boguslaw
2010-01-01
This article analyzes the historical and political context of Holocaust education, and its implementation in Polish schools. Perceptions of the Holocaust continue to change, influenced by Poland's social and political situation. The Polish historical context is quite specific; it includes the long history of Poles and Jews as neighbors, with local…
ERIC Educational Resources Information Center
Butler, Norman L.; Davidson, Barry S.; Pachocinski, Ryszard; Griffith, Kimberly Grantham; Kritsonis, William Allan
2007-01-01
This study compares Polish post-secondary vocational institutions with Canadian community colleges using an information technology conceptual framework. The research concentrated upon programs in information technology delivered by one Polish school Cracow School of Information Technology and two Canadian community colleges Durham (Oshawa,…
The Polish School System. Some Social and Historical Aspects.
ERIC Educational Resources Information Center
Holmberg, Carl, Ed.; Wojtowicz, Wit J., Ed.
A description of the Polish school-system and current educational research at the University of Gdansk (Poland) are included in this document. Articles included focus on two perspectives: (1) the social context in which schooling takes place; and (2) a historical outlook of the Polish system of education. Articles in this volume include:…
BEGINNING POLISH, VOLUME ONE. YALE LINGUISTIC SERIES.
ERIC Educational Resources Information Center
SCHENKER, ALEXANDER M.
BASED ON A MODERN LINGUISTIC ANALYSIS OF THE POLISH LANGUAGE, THIS TWO-VOLUME TEXT IS APPROPRIATE FOR A ONE-YEAR INTENSIVE COURSE. VOLUME I INCLUDES 25 LESSONS, EACH DIVIDED INTO--SENTENCES (DIALOGS), GRAMMAR, EXERCISES, AND VOCABULARY LISTS. THE INTRODUCTION PRESENTS A BRIEF CONTRASTIVE ANALYSIS OF POLISH AND RUSSIAN, AND THERE IS INCLUDED A…
Initial polishing time affects gloss retention in resin composites.
Waheeb, Nehal; Silikas, Nick; Watts, David
2012-10-01
To determine the effect of finishing and polishing time on the surface gloss of various resin-composites before and after simulated toothbrushing. Eight representative resin-composites (Ceram X mono, Ceram X duo, Tetric EvoCeram, Venus Diamond, EsteliteSigma Quick, Esthet.X HD, Filtek Supreme XT and Spectrum TPH) were used to prepare 80 disc-shaped (12 mm x 2 mm) specimens. The two step system Venus Supra was used for polishing the specimens for 3 minutes (Group A) and 10 minutes (Group B). All specimens were subjected to 16,000 cycles of simulated toothbrushing. The surface gloss was measured after polishing and after brushing using the gloss meter. Results were evaluated using one way ANOVA, two ways ANOVA and Dennett's post hoc test (P = 0.05). Group B (10-minute polishing) resulted in higher gloss values (GV) for all specimens compared to Group A (3 minutes). Also Group B showed better gloss retention compared to Group A after simulated toothbrushing. In each group, there was a significant difference between the polished composite resins (P < 0.05). For all specimens there was a decrease in gloss after the simulated toothbrushing.
Acoustic Correlates of Focus Marking in Czech and Polish.
Hamlaoui, Fatima; Żygis, Marzena; Engelmann, Jonas; Wagner, Michael
2018-05-01
Languages vary in the type of contexts that affect prosodic prominence. This paper reports on a production study investigating how different types of foci influence prosody in Polish and Czech noun phrases. The results show that in both languages, focus and givenness are marked prosodically, with pitch and intensity as the main acoustic correlates. Like Germanic languages, Polish and Czech patterns show prosodic focus marking in a broad range of contexts and differ in this regard from other fixed-word-stress languages such as French. This suggests that (a) Polish and Czech are similar to Germanic languages and are unlike Romance languages in marking a variety of types of focus prosodically; (b) there is no close correlation between fixed word stress and lack of prosodic focus marking because Polish, which has fixed stress on the penult, shows prosodic focus marking for all types of focus; and (c) there is no straightforward relationship between flexible word order and whether focus and givenness are prosodically marked, contrary to earlier claims, because both Czech and Polish, with their relatively flexible word order, are more similar to English than Romance languages.
[Cr-Ti-Al-N complex coating on titanium to strengthen Ti/porcelain bonding].
Zhang, Hui; Guo, Tian-wen; Li, Jun-ming; Pan, Jing-guang; Dang, Yong-gang; Tong, Yu
2006-02-01
To study the feasibility of magnetron sputtering Cr-Ti-Al-N complex coating as an interlayer on titanium to enhance the titanium-ceramic binding strength. With a three-point bending test according to ISO 9693, the binding strength of Duceratin (Degussa) to titanium substrate prepared with 4 different surface treatments (polishing, polishing and megnetron sputtering Cr, Ti, Al, and N complex coating, sandblasting, sandblasting and coating) was evaluated. Ti/porcelain interface and fractured Ti surface were examined using scanning electron microscopy with energy-dispersive spectrometry (EDS). The binding strength of polished and coated titanium/Duceratin was significantly higher than polished titanium group (P<0.05). The binding strength of sandblasted and coated titanium/Duceratin did not differ significantly from that of sandblasted titanium group (P>0.05), and the strength in the two sandblasted titanium groups was significantly higher than that in polished and coated titanium group (P<0.05). Megnetron sputtering Cr-Ti-Al-N complex on polished titanium can increase the titanium/porcelain binding strength. Megnetron sputtering coating is a promising Ti/porcelain interlayer.
Drago, Lorenzo; Del Fabbro, Massimo; Bortolin, Monica; Vassena, Christian; De Vecchi, Elena; Taschieri, Silvio
2014-11-01
Biofilm removal plays a central role in the prevention of periodontal and peri-implant diseases associated with microbial infections. Plaque debridement may be accomplished by air polishing using abrasive powders. In this study, a new formulation consisting of erythritol and chlorhexidine is compared with the standard glycine powder used in air-polishing devices. Their in vitro antimicrobial and antibiofilm effects on Staphylococcus aureus, Bacteroides fragilis, and Candida albicans are investigated. Biofilm was allowed to grow on sandblasted titanium disks and air polished with glycine or erythritol-chlorhexidine powders. A semiquantitative analysis of biofilm by spectrophotometric assay was performed. A qualitative analysis was also carried out by confocal laser scanning microscopy. Minimum inhibitory concentrations and minimum microbicidal concentrations were evaluated, together with the microbial recovery from the residual biofilm after air-polishing treatment. The combination of erythritol and chlorhexidine displayed stronger antimicrobial and antibiofilm activity than glycine against all microbial strains tested. Air polishing with erythritol-chlorhexidine seems to be a viable alternative to the traditional glycine treatment for biofilm removal.
Chen, Nan-Kuang; Lee, Cheng-Ling; Chi, Sien
2007-12-24
We demonstrate tunable highly wavelength-selective filter based on a 2 x 2 asymmetric side-polished fiber coupler with dispersive interlayer in one of the coupling arms. The asymmetric fiber coupler is made of two side-polished fibers using identical single-mode fibers and one of the polished fibers is further chemically etched at the central evanescent coupling region to gain closer to the core. An optical liquid with different dispersion characteristics than that of silica fiber is used to fill up the etched hollow and therefore the propagation constant for the polished fiber with dispersive liquid becomes more dispersive and crosses with that of another untreated polished fiber. The location of the cross point and the cross angle between two propagation constant curves determine the coupling wavelength and coupling bandwidth as well as channel wavelength separation, respectively. The coupling wavelength can be tuned at least wider than 84 nm (1.326-1.410 microm) under index variation of 0.004 and with coupling ratios of higher than 30 dB.
The role of food in the Polish migrant adjustment journey.
Brown, Lorraine; Paszkiewicz, Irena
2017-02-01
In 2015, there were 916,000 Poles living in the UK, making them the largest group of non-UK nationals at 16.5 percent of the population. Though increasingly research has focused on the consequences of this migration for both migrants themselves and the receiving country, little research has looked at food habits. This paper will explore the role of food in the Polish migrant adjustment journey. A qualitative approach was adopted, involving semi-structured interviews with nine Polish migrants. In this study, Polish migrants described the move to a new culture as a time of stress and loneliness. Due to a lack of money, they were forced to eat local food, which exacerbated their unease, as they found it to be tasteless and unhealthy. As soon as their financial situation improved, they reverted to a Polish diet, relying on ingredients brought from home, from London, or more recently, purchased from local Polish shops. This gave them comfort, and all participants acknowledged the vital role of food in their adjustment to life in a new culture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yet one more dwell time algorithm
NASA Astrophysics Data System (ADS)
Haberl, Alexander; Rascher, Rolf
2017-06-01
The current demand of even more powerful and efficient microprocessors, for e.g. deep learning, has led to an ongoing trend of reducing the feature size of the integrated circuits. These processors are patterned with EUV-lithography which enables 7 nm chips [1]. To produce mirrors which satisfy the needed requirements is a challenging task. Not only increasing requirements on the imaging properties, but also new lens shapes, such as aspheres or lenses with free-form surfaces, require innovative production processes. However, these lenses need new deterministic sub-aperture polishing methods that have been established in the past few years. These polishing methods are characterized, by an empirically determined TIF and local stock removal. Such a deterministic polishing method is ion-beam-figuring (IBF). The beam profile of an ion beam is adjusted to a nearly ideal Gaussian shape by various parameters. With the known removal function, a dwell time profile can be generated for each measured error profile. Such a profile is always generated pixel-accurately to the predetermined error profile, with the aim always of minimizing the existing surface structures up to the cut-off frequency of the tool used [2]. The processing success of a correction-polishing run depends decisively on the accuracy of the previously computed dwell-time profile. So the used algorithm to calculate the dwell time has to accurately reflect the reality. But furthermore the machine operator should have no influence on the dwell-time calculation. Conclusively there mustn't be any parameters which have an influence on the calculation result. And lastly it should take a minimum of machining time to get a minimum of remaining error structures. Unfortunately current dwell time algorithm calculations are divergent, user-dependent, tending to create high processing times and need several parameters to bet set. This paper describes an, realistic, convergent and user independent dwell time algorithm. The typical processing times are reduced to about 80 % up to 50 % compared to conventional algorithms (Lucy-Richardson, Van-Cittert …) as used in established machines. To verify its effectiveness a plane surface was machined on an IBF.
Tooth polishing: The current status
Sawai, Madhuri Alankar; Bhardwaj, Ashu; Jafri, Zeba; Sultan, Nishat; Daing, Anika
2015-01-01
Healthy teeth and gums make a person feel confident and fit. As people go about their daily routines and with different eating and drinking habits, the tooth enamel turns yellowish or gets stained. Polishing traditionally has been associated with the prophylaxis procedure in most dental practices, which patients know and expect. However, with overzealous use of polishing procedure, there is wearing of the superficial tooth structure. This would lead to more accumulation of local deposits. Also, it takes a long time for the formation of the fluoride-rich layer of the tooth again. Hence, now-a-days, polishing is not advised as a part of routine oral prophylaxis procedure but is done selectively based on the patients’ need. The article here, gives an insight on the different aspects of the polishing process along with the different methods and agents used for the same. PMID:26392683
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hubregsen, J.
1999-03-01
In the process of optical polishing, a new method has been developed called Magnetorheological Finishing, or MRF. This process utilizes both mechanical and chemical effects to remove material during polishing. To more fully understand the fundamental mechanisms of MR polishing the authors have successfully separated mechanical scratching from chemical softening in glass polishing with MRF by removing the water from the MR fluid. The addition of water initiates the chemical effects by hydrating the glass surface and changing the amplitude of the scratches. In addition, this study has found that the mechanical removal by scratching is related to the hardnessmore » of the magnetic carbonyl iron particles, and the hardness and type of the glass being polished.« less
Detection of paint polishing defects
NASA Astrophysics Data System (ADS)
Rebeggiani, S.; Wagner, M.; Mazal, J.; Rosén, B.-G.; Dahlén, M.
2018-06-01
Surface finish plays a major role on perceived product quality, and is the first thing a potential buyer sees. Today end-of-line repairs of the body of cars and trucks are inevitably to secure required surface quality. Defects that occur in the paint shop, like dust particles, are eliminated by manual sanding/polishing which lead to other types of defects when the last polishing step is not performed correctly or not fully completed. One of those defects is known as ‘polishing roses’ or holograms, which are incredibly hard to detect in artificial light but are clearly visible in sunlight. This paper will present the first tests with a measurement set-up newly developed to measure and analyse polishing roses. The results showed good correlations to human visual evaluations where repaired panels were estimated based on the defects’ intensity, severity and viewing angle.
Erickson, Robert P.; Larson-Thome, Katherine; Weberg, Lyndon; Szybinska, Aleksandra; Mossakowska, Malgorzata; Styczynska, Maria; Barcikowska, Maria; Kuznicki, Jacek
2008-01-01
There is abundant evidence that cholesterol metabolism, especially as mediated by the intercellular transporter APOE, is involved in the pathogenesis of sporadic, late-onset Alzheimer disease (SLAD). Identification of other genes involved in SLAD pathogenesis has been hampered since gene association studies, whether individual or genome-wide, experience difficulty in finding appropriate controls in as much as 25% or more of normal adults will develop SLAD. Using 152 centenarians as additional controls and 120 “regular,” 65- to 75-year-old controls, we show an association of genetic variation in NPC1 with SLAD and/or aging. In this preliminary study, we find gradients of two non-synonymous SNP’s allele frequencies in NPC1 from centenarians through normal controls to SLAD in this non-stratified Polish population. An intervening intronic SNP is not in Hardy-Weinberg equilibria and differs between centenarians and controls/SLAD. Haplotypes frequencies determined by fastPHASE were somewhat different, and the predicted genotype frequencies were very different between the 3 groups. These findings can also be interpreted as indicating a role for NPC1 in aging, a role also suggested by NPC1’s role in Dauer formation (hibernation, a longevity state) in C. elegans. PMID:18834923
Ereifej, N S; Oweis, Y G; Eliades, G
2013-01-01
The aim of this study was to compare surface roughness and gloss of resin composites polished using different polishing systems. Five resin composites were investigated: Filtek Silorane (FS), IPS Empress Direct (IP), Clearfil Majesty Posterior (CM), Premise (PM), and Estelite Sigma (ES). Twenty-five disk specimens were prepared from each material, divided into five groups, each polished with one of the following methods: Opti1Step (OS), OptiDisc (OD), Kenda CGI (KD), Pogo (PG), or metallurgical polishing (ML). Gloss and roughness parameters (Sa, Sz, Sq, and St) were evaluated by 60°-angle glossimetry and white-light interferometric profilometry. Two-way analysis of variance was used to detect differences in different materials and polishing techniques. Regression and correlation analyses were performed to examine correlations between roughness and gloss. Significant differences in roughness parameters and gloss were found according to the material, type of polishing, and material/polishing technique (p< 0.05). The highest roughness was recorded when KD was used (Sa: 581.8 [62.1] for FS/KD, Sq: 748.7 [55.6] for FS/KD, Sz: 17.7 [2.7] for CM/KD, and St: 24.6 [6.8] for FS/KD), while the lowest was recorded after ML (Sa: 133.6 [68.9] for PM/ML, Sq: 256.5 [53.5] for ES/ML, Sz: 4.0 [1.3] for ES/ML, and St: 7.1 [0.7] for ES/ML). The highest gloss was recorded for PM/ML (88.4 [2.3]) and lowest for FS/KD (30.3 [5.7]). All roughness parameters were significantly correlated with gloss (r= 0.871, 0.846, 0.713, and 0.707 for Sa, Sq, Sz, St, and gloss, respectively). It was concluded that the polishing procedure and the type of composite can have significant impacts on surface roughness and gloss of resin composites.
An evaluation of wear when enamel is opposed by various ceramic materials and gold.
Elmaria, Asmaa; Goldstein, Gary; Vijayaraghavan, Therizhandur; Legeros, Raquel Z; Hittelman, Eugene L
2006-11-01
Ceramic restorations have been known to cause wear of opposing enamel. The purpose of this study was to evaluate enamel wear caused by 3 ceramic substrates in the glazed and polished conditions. Sixty ceramic discs (10 x 2 mm)-20 each of Finesse, All-Ceram, and IPS-Empress-were prepared and glazed. Each group of 20 was divided into 2 groups of 10. The surfaces of one group were ground and polished using a porcelain polishing kit (Dialite). The remaining 10 were left as glazed. Ten specimens of a type III gold alloy were cast into rectangular shapes of 10 x 12 x 2 mm and polished. Seventy human cusps were prepared from sound, caries-free, extracted teeth and abraded against the substrates in a wear machine for a total of 10,000 cycles. The cusp height loss was traced before and after the wear test using a profile projector. Mean surface roughness (R(a)) values for the substrates were also recorded with a profilometer before testing. Differences in R(a) were evaluated using 1- and 2-way ANOVA and the Scheffe post hoc test (alpha = .05). One-way ANOVA indicated that enamel height loss was significantly different by material (P < .001) and surface condition (glazed and polished or glazed; P < .05). Gold, polished Finesse, and polished All-Ceram were the least abrasive, whereas glazed IPS-Empress was the most abrasive. There was no significant interaction effect between substrate type and surface condition. Significant differences were found when R(a) of the substrate condition was compared with enamel wear (P < .01). Gold, polished Finesse, and polished All-Ceram caused the least enamel wear, whereas IPS-Empress caused the most wear. Cast gold was significantly different than glazed IPS-Empress (P < .05), whereas other groups overlapped. There was significant correlation between R(a) and enamel wear (P < .01).
Chwastyk-Kowalczyk, Jolanta
2015-01-01
This article presents the history of establishment, functioning and the role of "Science and Technology"--quarterly of the Association of Polish Engineers in Great Britain--in shaping Polish technical thought in the environment of Polish engineers and technicians living in exile. The analysis of the content of the journal published in London in the years 1958-2008 made it evident that this official scientific organ of Polish technical intelligentsia edited in 500 copies reaches members of engineering, technical and scientific milieu across many continents. Despite the fact that Polish language dominates in the articles and thanks to the interdisciplinary character of their content - science and technology, biology, the humanities, sociology and others--the journal makes it possible for the reader to participate in an intellectual adventure. "Science and Technology" was created in 1958 on the initiative of Eng. Prof. Roman Wajda in Great Britain, with support of other Polish technical associations abroad, and embraced the achievements and organisational life of the Polish technical milieu dispersed around the world. On the basis of the London Society's archive materials and old annual volumes of the journal, the author listed editors-in-chief, composition of editorial committees, collaborators, determined editing costs, changeable periodicity, successive print shops, seats of editorial office that always followed the Association in Great Britain. She also showed the effort of a handful of members of editorial committees, working on a voluntary basis to obtain materials for the journal; the role of the journal linking Polish engineers and technicians in exile and its function as a link with the Country, as well as its role in the sphere of information and propaganda. Finally, the author made an analysis of the journal's content, focusing on categories of articles published in "Science and Technology" in the years 1958-2008. Methods used by the author in the article: archival, analysis of the press content: qualitative and quantitative.
Measuring Skew in Average Surface Roughness as a Function of Surface Preparation
NASA Technical Reports Server (NTRS)
Stahl, Mark
2015-01-01
Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.
Method for producing smooth inner surfaces
Cooper, Charles A.
2016-05-17
The invention provides a method for preparing superconducting cavities, the method comprising causing polishing media to tumble by centrifugal barrel polishing within the cavities for a time sufficient to attain a surface smoothness of less than 15 nm root mean square roughness over approximately a 1 mm.sup.2 scan area. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media bound to a carrier to tumble within the cavities. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media in a slurry to tumble within the cavities.
Hunt, N P; Cunningham, S J; Golden, C G; Sheriff, M
1999-10-01
The purpose of this study was to investigate the effect of surface roughness on the relative corrosion rates of wires of four alloys-stainless steel, nickel titanium, cobalt chromium, and beta titanium. Batches of wire were divided into two groups. Wires in one group were industrially polished to provide a uniform surface finish; wires in the other group were left for comparison "as received." Wire diameter, hardness, and relative corrosion rates were compared within groups before and after polishing. Comparisons were also made across the four groups of alloys. The samples of as-received wires showed variations in surface finish, with beta titanium having the roughest appearance and cobalt chromium the smoothest. Nickel titanium and stainless steel surfaces were similar. Polishing provided a more uniform finish, but significantly reduced the diameter of the wires. Microhardness testing of wire surfaces of each alloy indicated that no significant work-hardening occurred as a result of polishing. The relative corrosion rates (expressed in terms of corrosion current density) in a 0.9% sodium chloride solution were estimated using the electrochemical technique of polarization resistance. Nickel titanium wires exhibited the greatest corrosion current density in the as-received state. Polishing significantly reduced the corrosion rate of nickel titanium, such that comparison between the four alloys in the polished state revealed no significant difference in their relative corrosion rate/corrosion current density.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A; Ehrmann, P R; Bickel, R C
2009-11-05
Over the past year we have been working on specialized MR fluids for polishing KDP crystals. KDP is an extremely difficult material to conventionally polish due to its water solubility, low hardness, and temperature sensitivity. Today, KDP crystals are finished using single-point diamond turning (SPDT) tools and nonaqueous lubricants/coolants. KDP optics fabricated using SPDT, however, are limited to surface corrections due to tool/method characteristics with surface quality driven by microroughness from machine pitch, speed, force, and diamond tool character. MRF polishing offers a means to circumvent many of these issues since it is deterministic which makes the technique practical formore » surface and transmitted wavefront correction, is low force, and is temperature independent. What is lacking is a usable nonaqueous MR fluid that is chemically and physically compatible with KDP which can be used for polishing and subsequently cleaned from the optical surface. In this study, we will present the fluid parameters important in the design and development of nonaqueous MR fluid formulations capable of polishing KDP and how these parameters affect MRF polishing. We will also discuss requirements peculiar to successful KDP polishing and how they affect optical figure/finish and laser damage performance at 1064 nm and 532 nm.« less
Rahal, Juliana Saab; Mesquita, Marcelo Ferraz; Henriques, Guilherme Elias Pessanha; Nóbilo, Mauro Antonio Arruda
2004-01-01
Influence of polishing methods on water sorption and solubility of denture base acrylic resins was studied. Eighty samples were divided into groups: Classico (CL), and QC 20 (QC) - hot water bath cured; Acron MC (AC), and Onda Cryl (ON) - microwave cured; and submitted to mechanical polishing (MP) - pumice slurry, chalk powder, soft brush and felt cone in a bench vise; or chemical polishing (CP) - heated monomer fluid in a chemical polisher. The first desiccation process was followed by storage in distilled water at 37 +/- 1 degrees C for 1 h, 1 day, 1, 2, 3 and 4 weeks. Concluding each period, water sorption was measured. After the fourth week, a second desiccation process was done to calculate solubility. Data were submitted to analysis of variance, followed by Tukey test (p
Global Citizenship Education in School Curricula. A Polish Perspective
ERIC Educational Resources Information Center
Leek, Joanna
2016-01-01
The purpose of this study is to present global citizenship education from a Polish perspective. Analyzing the issue, the first part of this paper presents the development of citizenship education, followed by the current status of global citizenship education in Polish schools. In the second part of the study I draw attention to national curricula…
The Ranking of Global Environmental Issues and Problems by Polish Secondary Students and Teachers.
ERIC Educational Resources Information Center
Robinson, Michael; Trojok, Tomasz; Norwisz, Jan
1997-01-01
Identifies and discusses Polish student and teacher priorities of Bybee's 12 environmental problems in two cities in Katowice Province. Provides pertinent background on the Polish educational system. Presents reasons why the current science teaching model must be changed if the science curriculum is to provide more understanding of Bybee's 12…
Holding fixture for metallographic mount polishing
Barth, Clyde H.; Cramer, Charles E.
1997-01-01
A fixture for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface.
ERIC Educational Resources Information Center
Clark, Lynn; Schleef, Erik
2010-01-01
In order to achieve full native-like competence in a second language, speakers must also acquire sociolinguistic awareness in that language. This paper reports the results of a study investigating the acquisition of sociolinguistic awareness among immigrant Polish adolescents learning English in the UK. This paper asks whether Polish-born…
Reading Function and Content Words in Subtitled Videos
ERIC Educational Resources Information Center
Krejtz, Izabela; Szarkowska, Agnieszka; Loginska, Maria
2016-01-01
In this study, we examined how function and content words are read in intra- and interlingual subtitles. We monitored eye movements of a group of 39 deaf, 27 hard of hearing, and 56 hearing Polish participants while they viewed English and Polish videos with Polish subtitles. We found that function words and short content words received less…
Anthology of Polish Poetry. Fulbright-Hays Summer Seminars Abroad Program, 1998 (Hungary/Poland).
ERIC Educational Resources Information Center
Smith, Thomas A.
This anthology, of more than 225 short poems by Polish authors, was created to be used in world literature classes in a high school with many first-generation Polish students. The following poets are represented in the anthology: Jan Kochanowski; Franciszek Dionizy Kniaznin; Elzbieta Druzbacka; Antoni Malczewski; Adam Mickiewicz; Juliusz Slowacki;…
ERIC Educational Resources Information Center
Dabrowska, Ewa; Tomasello, Michael
2008-01-01
Rapid acquisition of linguistic categories or constructions is sometimes regarded as evidence of innate knowledge. In this paper, we examine Polish children's early understanding of an idiosyncratic, language-specific construction involving the instrumental case--which could not be due to innate knowledge. Thirty Polish-speaking children aged 2; 6…
Word Boundaries in L2 Speech: Evidence from Polish Learners of English
ERIC Educational Resources Information Center
Schwartz, Geoffrey
2016-01-01
Acoustic and perceptual studies investgate B2-level Polish learners' acquisition of second language (L2) English word-boundaries involving word-initial vowels. In production, participants were less likely to produce glottalization of phrase-medial initial vowels in L2 English than in first language (L1) Polish. Perception studies employing word…
ERIC Educational Resources Information Center
Chalasinski, Jozef
Diaries of rural youth writing during the transformation period of the Polish Peoples Republic (1950-1960's) were analyzed in terms of: individual autonomization and historical processes; identification with the Polish Peoples Republic and self-awareness (direct experience and historical awareness); youth and the revolutionary spirit of…
Evaluating DLAB as a Predictor of Foreign Language Learning
2012-05-01
JT - Italian KP - Korean ML - Malay NE - Nepalese NR - Norwegian PF - Persian-Iranian PG - Persian-Afghan PJ - Punjabi PL - Polish...Lithuanian NR - Norwegian PF - Persian-Iranian PG - Persian-Afghan PJ - Punjabi PL - Polish PQ - Portuguese-Brazilian PT - Portuguese...Lithuanian NR - Norwegian PF - Persian-Iranian PG - Persian-Afghan PJ - Punjabi PL - Polish PQ - Portuguese-Brazilian PT - Portuguese-European
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zerka, M.
1998-07-01
The main objective of this presentation is to describe the current reform of the Polish electric power sector being under the transition from a state-owned and controlled system to the broadly liberalized, competitive and market-oriented industry structure. The Polish electric power system integration with Western European systems (UCPTE) in 1995, and the process of Poland accession to EU brings closer the issue of international competition, which the sector must be ready to face very soon. In the context of Polish aspiration for membership in the European Union, the electric power sector has many attributes that give one grounds to assumemore » that it is capable of meeting challenges posed by integration and may also facilitate the indispensable transformation in other areas of the Polish economy. Among the most important attributes the following should be mentioned: the implementation of new competition-promoting Energy Law determining the separation of three functions (creation of energy policy, regulation and ownership activities); implementation of the principle of regulated third party access to the grid ensuring the complete deregulation of electricity market; restructuring of the electric power sector with transparent determination of functioning of electric power sub sectors : generation, transmission and distribution; electricity market organization (determination of the position of PSE SA as the future Transmission System Operator and Pool Operator); determination of principles for the development of electricity generation sub sector with licensing procedures; co-operation with UCPTE and the development of co-operation within the CENTREL group (new CENTREL ad hoc group on hadronization of electricity markets).« less
Spina, Denis Roberto Falcão; Grossi, João Ricardo Almeida; Cunali, Rafael Schlögel; Baratto Filho, Flares; da Cunha, Leonardo Fernandes; Gonzaga, Carla Castiglia; Correr, Gisele Maria
2015-01-01
The aim of this study was to evaluate the discoloration effects of water, cola-based soft drink, coffee, and wine on resin composites used in restorative dentistry and the possibility of removing the stain with chair side manual polishing. The A2 shade of three materials was tested. Disc specimens were prepared. A spectrophotometer was used to measure the baseline CIE-Lab color parameters of each material (n=10) 24 hours after sample preparation. Samples were then immersed in a cola-based soft drink, coffee, or wine for 1 hour every day, for 30 days. For the remaining hours, the specimens were stored in distilled water. In the control group, the specimens were immersed in water for the whole period. The color differences (ΔE) were calculated after 7 and 30 days of storage, and after polishing with coarse Sof-Lex discs, and analyzed by two-way ANOVA with repeated measures and Tukey's HSD test (α=0.05). Luna presented higher ΔE values (3.41)a followed by Durafill (2.82)b and Herculite (2.24)c. For the drink solutions, ΔE values were higher for wine (4.40)a followed by coffee (2.59)b and for cola-based soft drink (2.23)c and water (2.13)c which were statistically similar. For time, ΔE values were higher for 30 days (3.97)a and then for 7 days (2.48)b and after polishing (2.04)c. The results indicate that color stability is material dependent. The types of drinks that patients consume also influence the color stability of restorative materials. PMID:27347551
Jankowski, Konrad S
2016-05-15
The study aimed to elucidate previously observed associations between morningness-eveningness and depressive symptomatology in university students. Relations between components of depressive symptomatology and morningness-eveningness were analysed. Nine hundred and seventy-four university students completed Polish versions of the Centre for Epidemiological Studies - Depression scale (CES-D; Polish translation appended to this paper) and the Composite Scale of Morningness. Principal component analysis (PCA) was used to test the structure of depressive symptoms. Pearson and partial correlations (with age and sex controlled), along with regression analyses with morning affect (MA) and circadian preference as predictors, were used. PCA revealed three components of depressive symptoms: depressed/somatic affect, positive affect, interpersonal relations. Greater MA was related to less depressive symptoms in three components. Morning circadian preference was related to less depressive symptoms in depressed/somatic and positive affects and unrelated to interpersonal relations. Both morningness-eveningness components exhibited stronger links with depressed/somatic and positive affects than with interpersonal relations. Three CES-D components exhibited stronger links with MA than with circadian preference. In regression analyses only MA was statistically significant for positive affect and better interpersonal relations, whereas more depressed/somatic affect was predicted by lower MA and morning circadian preference (relationship reversed compared to correlations). Self-report assessment. There are three groups of depressive symptoms in Polish university students. Associations of MA with depressed/somatic and positive affects are primarily responsible for the observed links between morningness-eveningness and depressive symptoms in university students. People with evening circadian preference whose MA is not lowered have less depressed/somatic affect. Copyright © 2016 Elsevier B.V. All rights reserved.
Simulation of Magnetic Field Assisted Finishing (MFAF) Process Utilizing Smart MR Polishing Tool
NASA Astrophysics Data System (ADS)
Barman, Anwesa; Das, Manas
2017-02-01
Magnetic field assisted finishing process is an advanced finishing process. This process is capable of producing nanometer level surface finish. In this process magnetic field is applied to control the finishing forces using magnetorheological polishing medium. In the current study, permanent magnet is used to provide the required magnetic field in the finishing zone. The working gap between the workpiece and the magnet is filled with MR fluid which is used as the polishing brush to remove surface undulations from the top surface of the workpiece. In this paper, the distribution of magnetic flux density on the workpiece surface and behaviour of MR polishing medium during finishing are analyzed using commercial finite element packages (Ansys Maxwell® and Comsol®). The role of magnetic force in the indentation of abrasive particles on the workpiece surface is studied. A two-dimensional simulation study of the steady, laminar, and incompressible MR fluid flow behaviour during finishing process is carried out. The material removal and surface roughness modelling of the finishing process are also presented. The indentation force by a single active abrasive particle on the workpiece surface is modelled during simulation. The velocity profile of MR fluid with and without application of magnetic field is plotted. It shows non-Newtonian property without application of magnetic field. After that the total material displacement due to one abrasive particle is plotted. The simulated roughness profile is in a good agreement with the experimental results. The conducted study will help in understanding the fluid behavior and the mechanism of finishing during finishing process. Also, the modelling and simulation of the process will help in achieving better finishing performance.
Jagiełło, Władysław; Marina, Jagiełło; Maciej, Kalina Roman; Jan, Barczyński Bartłomiej; Artur, Litwiniuk; Jarosław, Klimczak
2017-12-01
Fencing is a combat sport whose form of direct confrontation involves hitting the opponent with a weapon. The purpose of the study was to determine the properties of body composition of female representatives of the Polish national fencing team. The study involved 11 female athletes of the Polish national fencing team. Their age was 16-22 years (19±2.32), body weight 52-78 kg (59.7±7.4), body height 158-183 cm (167.46±6.10) and the training experience 7.64±3.47 years. The reference group consisted of 153 students of Warsaw University of Technology (Poland). Twenty basic somatic characteristics were measured. The following indices were calculated: slenderness, Rohrer's, BMI, Manouvrier's, and pelvic-shoulder indices. Density of the body, total body fat, active tissue, the overall profile of body composition and internal proportions of the body were determined. Analysis of internal proportions of factors of the athletes' body composition revealed significant differences in particular groups of features. The total size of the athletes' bodies is due to less-than-average magnitude of the length and stoutness characteristics and a high magnitude of adiposity (M = 0.63) in the Polish female national team of fencers (sabre) calculated from the normalized values for the control group. The proportions of features within the analysed factors revealed a significant advantage of the length of the upper extremity over the lower one and a distinct advantage of forearm musculature. The specific profile of body composition of female athletes practising sabre fencing is most likely due to long-term effects of training as well as the system of selection of persons with specific somatic prerequisites developed in the course of many years of training practice.
Grzybowski, Tomasz; Malyarchuk, Boris A; Derenko, Miroslava V; Perkova, Maria A; Bednarek, Jarosław; Woźniak, Marcin
2007-06-01
Mitochondrial DNA sequence variation was examined by the control region sequencing (HVS I and HVS II) and RFLP analysis of haplogroup-diagnostic coding region sites in 570 individuals from four regional populations of Poles and two Russian groups from northwestern part of the country. Additionally, sequences of complete mitochondrial genomes representing K1a1b1a subclade in Polish and Polish Roma populations have been determined. Haplogroup frequency patterns revealed in Poles and Russians are similar to those characteristic of other Europeans. However, there are several features of Slavic mtDNA pools seen on the level of regional populations which are helpful in the understanding of complex interactions of the Eastern and Western Slavic populations with other European groups. One of the most important is the presence of subhaplogroups U5b1b1, D5, Z1 and U8a with simultaneous scarcity of haplogroup K in populations of northwestern Russia suggesting the participation of Finno-Ugrian tribes in the formation of mtDNA pools of Russians from this region. The results of genetic structure analyses suggest that Russians from Velikii Novgorod area (northwestern Russia) and Poles from Suwalszczyzna (northeastern Poland) differ from all remaining Polish and Russian samples. Simultaneously, northwestern Russians and northeastern Poles bear some similarities to Baltic (Latvians) and Finno-Ugrian groups (Estonians) of northeastern Europe, especially on the level of U5 haplogroup frequencies. The occurrence of K1a1b1a subcluster in Poles and Polish Roma is one of the first direct proofs of the presence of Ashkenazi-specific mtDNA lineages in non-Jewish European populations.
The prevalence of overweight and obesity among Polish pre-school-aged children.
Kułaga, Zbigniew; Gurzkowska, Beata; Grajda, Aneta; Wojtyło, Małgorzata; Góźdź, Magdalena; Litwin, Mieczysław
2016-01-01
The aim of this study is to estimate the prevalence of overweight and obesity in a current, nationally representative, random sample of pre-school-aged children in Poland and to compare their overweight and obesity rates with their peers from the US and Norway. The height and weight were measured in a total of 5026 randomly sampled children aged 2-6 years and their Body Mass Index was calculated. The prevalence of overweight including obesity was determined using three definitions, i.e. those formulated by the International Obesity Task Force (IOTF), the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC). The overall prevalence of overweight including obesity in boys was 12.2%, 12.2%, 17.2% and in girls 15.0%, 10.0%, 19.1% according to the IOTF, WHO, CDC definition, respectively, and did not significantly differ in comparison with their US and Norwegian peers. The overall prevalence of obesity in boys was: 4.4%, 4.9%, 8.9% and in girls: 3.8%, 3.4%, 7.6%, according to the IOTF, WHO, CDC definition, respectively. Among Polish girls the obesity rate was higher compared to the female US peers. The obesity rate was higher in Polish boys compared to their Norwegian peers. The estimates of the prevalence of overweight and obesity varied substantially by age group, gender and depending on the definition used. Obesity rates among Polish girls and boys were higher compared to their American and Norwegian peers. The influence of overweight definitions should be taken into account when studying childhood overweight and obesity. Overweight and obesity preventive programs should be implemented at preschool age.
The Krakow clean fossil fuels and energy efficiency program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feibus, H.
1995-12-31
The joint effort by Polish and American organizations in Krakow has accomplished a great deal in just a few years. In particular, the low emission sources program has had major successes. Poland and America have a lot to learn from each other in the clean and economical use of coal. Both our countries are major producers and users of coal. Both have had to deal with the emissions of particulate and organics from coal combustion. We were fortunate, since our free market economy and democratic government helped us deal with a lot of these problems in the 1950s. In Poland,more » the freedom to solve these problems has evolved only in the last few years. In the first phase of the program, Polish and American engineers ran combustion tests on boilers and stoves in Krakow. They also performed analyses on the cost and feasibility of various equipment changes. The results of the first phase were used in refining the spreadsheet model to give better estimates of costs emissions. The first phase also included analyses of incentives for proceeding with needed changes. These analyses identified actions needed to create a market for the goods and services which control pollution. Such actions could include privatization, regulation, or financial incentives. The second phase of the program consisted of public meetings in Chicago, Washington, and Krakow. The purpose of the meetings was to inform U.S. and Polish firms about the results of phase 1 and to encourage them to compete to take part in phase 3. The third phase currently underway consists of the commercial ventures that were competitively selected. These ventures were consistent with recommendations unanimously made by the BSC. The three phases of the Polish-American program are discussed.« less
Andysz, Aleksandra; Jacukowicz, Aleksandra; Stańczak, Aleksander; Drabek, Marcin
2016-01-01
Polish Labour Code provides employees with a range of solutions (benefits) supporting them in achieving balance between work and private life. This paper was aimed at indicating availability and the use of legal benefits supporting work-life balance (WLB) among Polish workers of small and medium enterprises. The study sample included 219 respondents, aged 22-64, working in small and medium enterprises and employed on the basis of employment contracts for at least a year. The respondents completed a questionnaire on availability and the use of benefits guaranteed by the Polish Labour Code, referring to their current workplaces. Most frequently the studied employees took sick leave because of one's own illness and leave on demand. In our sample, 45% of the women took maternity leave and 26% of the men took paternity leave. The respondents took educational and parental leave the least frequently. More than half of the respondents (58%) did not return to the same position after leave devoted to childcare, even though they had such a possibility. In fact, most of work-life balance benefits guaranteed by law were available to the employees of small and medium enterprises, regardless of their gender. Availability and the use of the majority of benefits were similar among the women and men. Availability of benefits depended on the specificity of industry and a profession, thus, future research on work-life balance policy should control for variables related to the character of work. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Competency in ECG Interpretation Among Medical Students
Kopeć, Grzegorz; Magoń, Wojciech; Hołda, Mateusz; Podolec, Piotr
2015-01-01
Background Electrocardiogram (ECG) is commonly used in diagnosis of heart diseases, including many life-threatening disorders. We aimed to assess skills in ECG interpretation among Polish medical students and to analyze the determinants of these skills. Material/Methods Undergraduates from all Polish medical schools were asked to complete a web-based survey containing 18 ECG strips. Questions concerned primary ECG parameters (rate, rhythm, and axis), emergencies, and common ECG abnormalities. Analysis was restricted to students in their clinical years (4th–6th), and students in their preclinical years (1st–3rd) were used as controls. Results We enrolled 536 medical students (females: n=299; 55.8%), aged 19 to 31 (23±1.6) years from all Polish medical schools. Most (72%) were in their clinical years. The overall rate of good response was better in students in years 4th–5th than those in years 1st–3rd (66% vs. 56%; p<0.0001). Competency in ECG interpretation was higher in students who reported ECG self-learning (69% vs. 62%; p<0.0001) but no difference was found between students who attended or did not attend regular ECG classes (66% vs. 66%; p=0.99). On multivariable analysis (p<0.0001), being in clinical years (OR: 2.45 [1.35–4.46] and self-learning (OR: 2.44 [1.46–4.08]) determined competency in ECG interpretation. Conclusions Polish medical students in their clinical years have a good level of competency in interpreting the primary ECG parameters, but their ability to recognize ECG signs of emergencies and common heart abnormalities is low. ECG interpretation skills are determined by self-education but not by attendance at regular ECG classes. Our results indicate qualitative and quantitative deficiencies in teaching ECG interpretation at medical schools. PMID:26541993
Mullan, F; Mylonas, P; Parkinson, C; Bartlett, D; Austin, R S
2018-03-01
To assess the precision of optical profilometry for characterising the 3D surface roughness of natural and polished human enamel in order to reliably quantify acid mediated surface roughness changes in human enamel. Forty-two enamel samples were prepared from extracted human molars and either polished flat or left unmodified. To investigate precision, the variability of thirty repeated measurements of five areas of one polished and one natural enamel sample was assessed using 655nm Confocal Laser Profilometry. Remaining samples were subjected to forty-five minutes orange juice erosion and microstructural changes were analysed using Sa roughness change (μm) and qualitatively using surface/subsurface confocal microscopy. Enamel surface profilometry from the selected areas revealed maximal precision of 5nm for polished enamel and 23nm for natural enamel. After erosion, the polished enamel revealed a 48% increase in mean (SD) Sa roughness of 0.10 (0.07)μm (P<0.05), whereas in contrast the natural enamel revealed a 45% decrease in mean (SD) roughness of -0.32 (0.42)μm (P<0.05). These data were supported by qualitative confocal images of the surface/subsurface enamel. This study demonstrates a method for precise surface texture measurement of natural human enamel. Measurement precision was superior for polished flat enamel in contrast to natural enamel however, natural enamel responds very differently to polished enamel when exposed to erosion challenges. Therefore, thus future studies characterising enamel surface changes following erosion on natural enamel may provide more clinically relevant responses in comparison to polished enamel. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
[The study of ultra-fine diamond powder used in magnetic head polishing slurry].
Jin, Hong-Yun; Hou, Shu-En; Pan, Yong; Xiao, Hong-Yan
2008-05-01
In the present paper, atomic absorption spectrometry(AAS), inductively-coupled plasma mass spectrometry (ICP-MS), transmission electron microscopy (TEM), X-ray diffraction (XRD) and laser Raman spectroscopy (RM) were employed to study the commercial ultra-fine diamond powders prepared by the static pressure-catalyst method and used in magnetic head polishing slurry. The results of AAS and ICP-MS indicated that there were silicon oxide, Fe, Ni, Al and some other metal elements in the ultra-fine powders. XRD patterns showed the peaks of SiO2 at 2theta = 35.6 degrees, 39.4 degrees and 59.7 degrees and diamond sharp peaks in agreement with the results above. Diamond sharp peaks implied perfect crystal and high-hardness beneficial to high-efficiency in polishing. The broader Raman band of graphite at 1 592 cm(-1) observed by Raman analysis proved graphite existing in the diamond powders. In the TEM images, the size of ultra-fine powders was estimated between 0.1 and 0.5 microm distributed in a wide scope, however, sharp edges of the powder particles was useful to polish. The ultra-fine diamond powders have many advantages, for example, high-hardness, well abrasion performance, high-polishing efficiency and being useful in magnetic head polishing slurry. But, the impurities influence the polishing efficiency, shortening its service life and the wide distribution reduces the polishing precision. Consequently, before use the powders must be purified and classified. The purity demands is 99.9% and trace silicon oxide under 0.01% should be reached. The classification demands that the particle distribution should be in a narrower scope, with the mean size of 100 nm and the percentage of particles lager than 200 nm not over 2%.
Proportion of refractive errors in a Polish immigrant population in Chicago.
Allison, Christine L
2010-08-01
This retrospective record review was conducted to investigate the proportion of patients with refractive error in a Polish immigrant population residing in an urban environment. Illinois has more than 1 million people of Polish descent as citizens, and Chicago is considered to have the second largest population of Polish descent in the world, outside of Warsaw, Poland. Six hundred seventy-five records (271 men/404 women) of Polish immigrants were reviewed from a practice with >92% Polish immigrants in the patient base. The patients ranged in age from 3 to 94 years. Refractive status for each eye, and the existence of any strabismus or amblyopia, was recorded. The proportion of myopia [spherical equivalent at least -0.75 diopter (D)] was found to be 35.1%, whereas the proportion of hyperopia (spherical equivalent > or =+0.75 D) was found to be 38.4%. Fifteen percent of the patients exhibited astigmatism > or =1.00 D. Amblyopia was present in 9% of the patients, whereas the prevalence of strabismus was found to be 3%, with 76% of the strabismics exhibiting esotropia. In the 0- to 18-year age range and the 19- to 45-year age range, the most common refractive error was low myopia (43.9 and 36.9%), whereas in the patients >45 years of age, it was low hyperopia (31.2%). Refractive error data are presented for a population base that has not been previously reported, although Polish Americans comprise 3% of the US population. Myopia is more common in young Polish patients than in the general US population. The strong hyperopic shift in older patients may either be normal aging or the product of increased near work in the young. The high rates of amblyopia call for more aggressive education and treatment.
Nd:YOV4 laser polishing on WC-Co HVOF coating
NASA Astrophysics Data System (ADS)
Giorleo, L.; Ceretti, E.; Montesano, L.; La Vecchia, G. M.
2017-10-01
WC/Co coatings are widely applied to different types of components due to their extraordinary performance properties including high hardness and wear properties. In industrial applications High Velocity Oxy-Fuel (HVOF) technique is extensively used to deposit hard metal coatings. The main advantage of HVOF compared to other thermal spray techniques is the ability to accelerate the melted powder particles of the feedstock material at a relatively high velocity, leading to obtain good adhesion and low porosity level. However, despite the mentioned benefits, the surface finish quality of WC-Co HVOF coatings results to be poor (Ra higher than 5 µm) thus a mechanical polishing process is often needed. The main problem is that the high hardness of coating leads the polishing process expensive in terms of time and tool wear; moreover polishing becomes difficult and not always possible in case of limited accessibility of a part, micro dimensions or undercuts. Nowadays a different technique available to improve surface roughness is the laser polishing process. The polishing principle is based on focused radiation of a laser beam that melts a microscopic layer of surface material. Compared to conventional polishing process (as grinding) it ensures the possibility of avoiding tool wear, less pollution (no abrasive or liquids), no debris, less machining time and coupled with a galvo system it results to be more suitable in case of 3D complex workpieces. In this paper laser polishing process executed with a Nd:YOV4 Laser was investigated: the effect of different process parameters as initial coating morphology, laser scan speed and loop cycles were tested. Results were compared by a statistical approach in terms of average roughness along with a morphological analysis carried out by Scanning Electron Microscope (SEM) investigation coupled with EDS spectra.
Research on high-efficiency polishing technology of photomask substrate
NASA Astrophysics Data System (ADS)
Zhao, Shijie; Xie, Ruiqing; Zhou, Lian; Liao, Defeng; Chen, Xianhua; Wang, Jian
2018-03-01
A method of photomask substrate fabrication is demonstrated ,that the surface figure and roughness of fused silica will converge to target precision rapidly with the full aperture polishing. Surface figure of optical flats in full aperture polishing processes is primarily dependent on the surface profile of polishing pad, therefor, a improved function of polishing mechanism was put forward based on two axis lapping machine and technology experience, and the pad testing based on displacement sensor and the active conditioning method of the pad is applied in this research. Moreover , the clamping deformation of the thin glass is solved by the new pitch dispensing method. The experimental results show that the surface figure of the 152mm×152mm×6.35mm optical glass is 0.25λ(λ=633nm) and the roughness is 0.32nm ,which has meet the requirements of mask substrate for 90 45nm nodes.
Removal rate model for magnetorheological finishing of glass.
Degroote, Jessica E; Marino, Anne E; Wilson, John P; Bishop, Amy L; Lambropoulos, John C; Jacobs, Stephen D
2007-11-10
Magnetorheological finishing (MRF) is a deterministic subaperture polishing process. The process uses a magnetorheological (MR) fluid that consists of micrometer-sized, spherical, magnetic carbonyl iron (CI) particles, nonmagnetic polishing abrasives, water, and stabilizers. Material removal occurs when the CI and nonmagnetic polishing abrasives shear material off the surface being polished. We introduce a new MRF material removal rate model for glass. This model contains terms for the near surface mechanical properties of glass, drag force, polishing abrasive size and concentration, chemical durability of the glass, MR fluid pH, and the glass composition. We introduce quantitative chemical predictors for the first time, to the best of our knowledge, into an MRF removal rate model. We validate individual terms in our model separately and then combine all of the terms to show the whole MRF material removal model compared with experimental data. All of our experimental data were obtained using nanodiamond MR fluids and a set of six optical glasses.
Electrochemical and mechanical polishing and shaping method and system
NASA Technical Reports Server (NTRS)
Engelhaupt, Darell E. (Inventor); Gubarev, Mikhail V. (Inventor); Jones, William David (Inventor); Ramsey, Brian D. (Inventor); Benson, Carl M. (Inventor)
2011-01-01
A method and system are provided for the shaping and polishing of the surface of a material selected from the group consisting of electrically semi-conductive materials and conductive materials. An electrically non-conductive polishing lap incorporates a conductive electrode such that, when the polishing lap is placed on the material's surface, the electrode is placed in spaced-apart juxtaposition with respect to the material's surface. A liquid electrolyte is disposed between the material's surface and the electrode. The electrolyte has an electrochemical stability constant such that cathodic material deposition on the electrode is not supported when a current flows through the electrode, the electrolyte and the material. As the polishing lap and the material surface experience relative movement, current flows through the electrode based on (i) adherence to Faraday's Law, and (ii) a pre-processing profile of the surface and a desired post-processing profile of the surface.
Chao, E.C.T.
1976-01-01
Recently discovered mineral-produced, deeply incised striae and mirror-like polish on broken surfaces of limestone fragments from the sedimentary ejecta of the Ries impact crater of southern Germany are described. The striae and polish were produced under high confining pressures during high-velocity nonballistic transport of the ejecta mass within the time span of the cratering event (measured in terms of seconds). The striae on these fragments were produced by scouring by small mineral grains embedded in the surrounding clay matrix, and the polish was formed under the same condition, by movements of relatively fragment-free clay against the fragment surfaces. The occurrence of these striae and polish is key evidence for estimating the distribution and determining the relative importance of nonballistic and ballistic transport of ejecta from the shallow Ries stony meteorite impact crater.
History of pediatric neurology in Poland.
Steinborn, Barbara; Józwiak, Sergiusz
2010-02-01
This review presents the past and the present of pediatric neurology in Poland. Pediatric neurology has its roots in Polish general neurology represented by many outstanding scientists. The founder of Polish school of neurology at the end of 19th century was Edward Flatau, known as the author of Flatau's law. The most famous Polish neurologist was Joseph Babiński, recognized for the first description of pathological plantar reflex. First Polish publication related to child neurology was Brudziński's report on a new meningeal symptom (the flexion of lower limbs during passive neck flexion with pain in neck). Contemporary child neurology in Poland was created by Professor Zofia Majewska after the Second World War. Now 10 academic centers of child neurology exist in Poland fulfilling educational, scientific, and therapeutic roles. Polish Society of Child Neurology was established in 1991 and now there are about 580 members, including 300 child neurologists.
Lysenko affair and Polish botany.
Köhler, Piotr
2011-01-01
This article describes the slight impact of Lysenkoism upon Polish botany. I begin with an account of the development of plant genetics in Poland, as well as the attitude of scientists and the Polish intelligentsia toward Marxist philosophy prior to the World War II. Next I provide a short history of the introduction and demise of Lysenkoism in Polish science, with a focus on events in botany, in context with key events in Polish science from 1939 to 1958. The article outlines the little effects of Lysenkoism upon botanists and their research, as well as how botanists for the most part rejected what was often termed the "new biology." My paper shows that though Lysenko's theories received political support, and were actively promoted by a small circle of scientists and Communist party activists, they were never accepted by most botanists. Once the political climate in Poland altered after the events of 1956, Lysenko's theories were immediately abandoned.
Pressure distribution under flexible polishing tools. I - Conventional aspheric optics
NASA Astrophysics Data System (ADS)
Mehta, Pravin K.; Hufnagel, Robert E.
1990-10-01
The paper presents a mathematical model, based on Kirchoff's thin flat plate theory, developed to determine polishing pressure distribution for a flexible polishing tool. A two-layered tool in which bending and compressive stiffnesses are equal is developed, which is formulated as a plate on a linearly elastic foundation. An equivalent eigenvalue problem and solution for a free-free plate are created from the plate formulation. For aspheric, anamorphic optical surfaces, the tool misfit is derived; it is defined as the result of movement from the initial perfect fit on the optic to any other position. The Polisher Design (POD) software for circular tools on aspheric optics is introduced. NASTRAN-based finite element analysis results are compared with the POD software, showing high correlation. By employing existing free-free eigenvalues and eigenfunctions, the work may be extended to rectangular polishing tools as well.