Sample records for computer software angle

  1. Development of a software package for solid-angle calculations using the Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Zhang, Jie; Chen, Xiulian; Zhang, Changsheng; Li, Gang; Xu, Jiayun; Sun, Guangai

    2014-02-01

    Solid-angle calculations play an important role in the absolute calibration of radioactivity measurement systems and in the determination of the activity of radioactive sources, which are often complicated. In the present paper, a software package is developed to provide a convenient tool for solid-angle calculations in nuclear physics. The proposed software calculates solid angles using the Monte Carlo method, in which a new type of variance reduction technique was integrated. The package, developed under the environment of Microsoft Foundation Classes (MFC) in Microsoft Visual C++, has a graphical user interface, in which, the visualization function is integrated in conjunction with OpenGL. One advantage of the proposed software package is that it can calculate the solid angle subtended by a detector with different geometric shapes (e.g., cylinder, square prism, regular triangular prism or regular hexagonal prism) to a point, circular or cylindrical source without any difficulty. The results obtained from the proposed software package were compared with those obtained from previous studies and calculated using Geant4. It shows that the proposed software package can produce accurate solid-angle values with a greater computation speed than Geant4.

  2. Research in Varying Burner Tilt Angle to Reduce Rear Pass Temperature in Coal Fired Boiler

    NASA Astrophysics Data System (ADS)

    Thrangaraju, Savithry K.; Munisamy, Kannan M.; Baskaran, Saravanan

    2017-04-01

    This research shows the investigation conducted on one of techniques that is used in Manjung 700 MW tangentially fired coal power plant. The investigation conducted in this research is finding out the right tilt angle for the burners in the boiler that causes an efficient temperature distribution and combustion gas flow pattern in the boiler especially at the rear pass section. The main outcome of the project is to determine the right tilt angle for the burner to create an efficient temperature distribution and combustion gas flow pattern that able to increase the efficiency of the boiler. The investigation is carried out by using Computational Fluid Dynamics method to obtain the results by varying the burner tilt angle. The boiler model is drawn by using designing software which is called Solid Works and Fluent from Computational Fluid Dynamics is used to conduct the analysis on the boiler model. The analysis is to imitate the real combustion process in the real Manjung 700 MW boiler. The expected results are to determine the right burner tilt angle with a computational fluid analysis by obtaining the temperature distribution and combustion gas flow pattern for each of the three angles set for the burner tilt angle in FLUENT software. Three burner tilt angles are selected which are burner tilt angle at (0°) as test case 1, burner tilt angle at (+10°) as test case 2 and burner tilt angle at (-10°) as test case 3. These entire three cases were run in CFD software and the results of temperature distribution and velocity vector were obtained to find out the changes on the three cases at the furnace and rear pass section of the boiler. The results are being compared in analysis part by plotting graphs to determine the right tilting angle that reduces the rear pass temperature.

  3. Orbits: Computer simulation

    NASA Technical Reports Server (NTRS)

    Muszynska, A.

    1985-01-01

    In rotating machinery dynamics an orbit (Lissajous curve) represents the dynamic path of the shaft centerline motion during shaft rotation and resulting precession. The orbit can be observed with an oscilloscope connected to XY promixity probes. The orbits can also be simulated by a computer. The software for HP computer simulates orbits for two cases: (1) Symmetric orbit with four frequency components with different radial amplitudes and relative phase angles; and (2) Nonsymmetric orbit with two frequency components with two different vertical/horizontal amplitudes and two different relative phase angles. Each orbit carries a Keyphasor mark (one-per-turn reference). The frequencies, amplitudes, and phase angles, as well as number of time steps for orbit computation, have to be chosen and introduced to the computer by the user. The orbit graphs can be observed on the computer screen.

  4. Formulation of additional observables for ENTREE

    NASA Technical Reports Server (NTRS)

    Findlay, J. T.; Heck, M. L.

    1980-01-01

    The S-band X and Y angles, SAMS, and TACAN range and bearing were incorporated into the ENTREE software for use by experimenters at LaRC for entry trajectory reconstruction purposes. Background discussions present the need for this added capability. Formulations for the various observables are presented. Both north-south and east-west antenna mounts were provided for in the S-band angle computations. Sub-vehicle terrain height variations are included in the SAMS model. Local magnetic variations were incorporated for the TACAN bearing computations. Observable formulations are discussed in detail along with the partial computations.

  5. Evaluation of the discrete vortex wake cross flow model using vector computers. Part 1: Theory and application

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The current program had the objective to modify a discrete vortex wake method to efficiently compute the aerodynamic forces and moments on high fineness ratio bodies (f approximately 10.0). The approach is to increase computational efficiency by structuring the program to take advantage of new computer vector software and by developing new algorithms when vector software can not efficiently be used. An efficient program was written and substantial savings achieved. Several test cases were run for fineness ratios up to f = 16.0 and angles of attack up to 50 degrees.

  6. HolT Hunter: Software for Identifying and Characterizing Low-Strain DNA Holliday Triangles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman W. B.

    2012-06-05

    Synthetic DNA nanostructures are most commonly held together via Holliday junctions. These junctions allow for a wide variety of different angles between the double helices they connect. Nevertheless, only constructs with a very limited selection of angles have been built, to date, because of the computational complexity of identifying structures that fit together with low strain at odd angles. I have developed an algorithm that finds over 95% of the possible solutions by breaking the problem down into two portions. First, there is a problem of how smooth rods can form triangles by lying across one another. This problem ismore » easily handled by numerical computation. Second, there is the question of how distorted DNA double helices would need to be to fit onto the rod structure. This strain is calculated directly. The algorithm has been implemented in a Mathematica 8 notebook called Holliday Triangle Hunter. A large database of solutions has been identified. Additional interface software is available to facilitate drawing and viewing models.« less

  7. Inviscid Flow Computations of Several Aeroshell Configurations for a '07 Mars Lander

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    2001-01-01

    This report documents the results of an inviscid computational study conducted on several candidate aeroshell configurations for a proposed '07 Mars lander. Eleven different configurations were considered, and the aerodynamic characteristics of each of these were computed for a Mach number of 23.7 at 10, 15, and 20 degree angles of attack. The unstructured grid software FELISA with the equilibrium Mars gas option was used for these computations. The pitching moment characteristics and the lift-to-drag ratios at trim angle of attack of each of these configurations were examined to make a selection. The criterion for selection was that the configuration should be longitudinally stable, and should trim at an angle of attack where the L/D is -0.25. Based on the present study, two configurations were selected for further study

  8. Inviscid Flow Computations of the Shuttle Orbiter for Mach 10 and 15 and Angle of Attack 40 to 60 Degrees

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Sutton, Kenneth (Technical Monitor)

    2001-01-01

    This report documents the results of a computational study done to compute the inviscid longitudinal aerodynamic characteristics of the Space Shuttle Orbiter for Mach numbers 10 and 15 at angles of attack of 40, 50, 55, and 60 degrees. These computations were done to provide limited aerodynamic data in support of the Orbiter contingency abort task. The Orbiter had all the control surfaces in the undeflected position. The unstructured grid software FELISA was used for these computations with the equilibrium air option. Normal and axial force coefficients and pitching moment coefficients were computed. The hinge moment coefficients of the body flap and the inboard and outboard elevons were also computed. These results were compared with Orbiter Air Data Book (OADB) data and those computed using GASP. The comparison with the GASP results showed very good agreement in Cm and Ca at all the points. The computed axial force coefficients were smaller than those computed by GASP. There were noticeable differences between the present results and those in the OADB at angles of attack greater than 50 degrees.

  9. A Fast Algorithm to Compute Conical Pockets in Proteins. Application to the Structural Characterization of γ-Carbonic Anhydrases.

    PubMed

    Petitjean, Michel

    2017-10-01

    Some major proteins families, such as carbonic anhydrases (CAs), have a conical cavity at the active site. No algorithm was available to compute conical cavities, so we needed to design one. The fast algorithm we designed let us show on a set of 717 CAs extracted from the PDB database that γ-CAs are characterized by active site cavity cone angles significantly larger than those of α-CAs and β-CAs: the generatrix-axis angles are greater than 60° for the γ-CAs while they are smaller than 50° for the other CAs. Free binaries of the CONICA software implementing the algorithm are available through a software repository at http://petitjeanmichel.free.fr/itoweb.petitjean.freeware.html. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Comparison of Computational and Experimental Results for a Transonic Variable-Speed Power-Turbine Blade Operating with Low Inlet Turbulence Levels

    NASA Technical Reports Server (NTRS)

    Booth, David; Flegel, Ashlie

    2015-01-01

    A computational assessment of the aerodynamic performance of the midspan section of a variable-speed power-turbine blade is described. The computation comprises a periodic single blade that represents the 2-D Midspan section VSPT blade that was tested in the NASA Glenn Research Center Transonic Turbine Blade Cascade Facility. A commercial, off-the-shelf (COTS) software package, Pointwise and CFD++, was used for the grid generation and RANS and URANS computations. The CFD code, which offers flexibility in terms of turbulence and transition modeling options, was assessed in terms of blade loading, loss, and turning against test data from the transonic tunnel. Simulations were assessed at positive and negative incidence angles that represent the turbine cruise and take-off design conditions. The results indicate that the secondary flow induced at the positive incidence cruise condition results in a highly loaded case and transitional flow on the blade is observed. The negative incidence take-off condition is unloaded and the flow is very two-dimensional. The computational results demonstrate the predictive capability of the gridding technique and COTS software for a linear transonic turbine blade cascade with large incidence angle variation.

  11. Comparison of Computational and Experimental Results for a Transonic Variable-speed Power-Turbine Blade Operating with Low Inlet Turbulence Levels

    NASA Technical Reports Server (NTRS)

    Booth, David T.; Flegel, Ashlie B.

    2015-01-01

    A computational assessment of the aerodynamic performance of the midspan section of a variable-speed power-turbine blade is described. The computation comprises a periodic single blade that represents the 2-D Midspan section VSPT blade that was tested in the NASA Glenn Research Center Transonic Turbine Blade Cascade Facility. A commercial, off-the-shelf (COTS) software package, Pointwise and CFD++, was used for the grid generation and RANS and URANS computations. The CFD code, which offers flexibility in terms of turbulence and transition modeling options, was assessed in terms of blade loading, loss, and turning against test data from the transonic tunnel. Simulations were assessed at positive and negative incidence angles that represent the turbine cruise and take-off design conditions. The results indicate that the secondary flow induced at the positive incidence cruise condition results in a highly loaded case and transitional flow on the blade is observed. The negative incidence take-off condition is unloaded and the flow is very two-dimensional. The computational results demonstrate the predictive capability of the gridding technique and COTS software for a linear transonic turbine blade cascade with large incidence angle variation.

  12. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools.

    PubMed

    Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo

    2014-02-06

    Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL.

  13. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools

    PubMed Central

    2014-01-01

    Background Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Methods Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. Results There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2–T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson’s coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Conclusion Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino-pelvic measurement in T2-T5, PT, PI, SS, and LL. PMID:24502397

  14. Software for Testing Electroactive Structural Components

    NASA Technical Reports Server (NTRS)

    Moses, Robert W.; Fox, Robert L.; Dimery, Archie D.; Bryant, Robert G.; Shams, Qamar

    2003-01-01

    A computer program generates a graphical user interface that, in combination with its other features, facilitates the acquisition and preprocessing of experimental data on the strain response, hysteresis, and power consumption of a multilayer composite-material structural component containing one or more built-in sensor(s) and/or actuator(s) based on piezoelectric materials. This program runs in conjunction with Lab-VIEW software in a computer-controlled instrumentation system. For a test, a specimen is instrumented with appliedvoltage and current sensors and with strain gauges. Once the computational connection to the test setup has been made via the LabVIEW software, this program causes the test instrumentation to step through specified configurations. If the user is satisfied with the test results as displayed by the software, the user activates an icon on a front-panel display, causing the raw current, voltage, and strain data to be digitized and saved. The data are also put into a spreadsheet and can be plotted on a graph. Graphical displays are saved in an image file for future reference. The program also computes and displays the power and the phase angle between voltage and current.

  15. Inviscid Flow Computations of the Orbital Sciences X-34 Over a Mach Number Range of 1.25 to 6.0

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    2001-01-01

    This report documents the results of an inviscid computational study conducted on the Orbital Sciences X-34 vehicle to compute its inviscid longitudinal aerodynamic characteristics over a Mach number range of 1.25 to 6.0. The unstructured grid software FELISA was used and th e aerodynamic characteristics were computed at Mach numbers 1.25, 1.6, 2.5, 4.0, 4.63, and 6.0, and an angle of attack range of -4 to 32 degrees. These results were compared with available aerodynamic data from wind tunnel test on X-34 models. The comparison showed excellent agreement in C(sub N). The computed pitching moment compared well at Mach numbers 2.5 and higher, and at angles of attack of up to 12 deg. The agreement was not good at higher angles of attack possibly due to viscous effects. At lower Mach numbers there were significant differences between computed and measured C(sub m) values. This could not be explained. Since the present computations are inviscid, the computed C(sub A) was consistently lower than the measured values as expected.

  16. Angle Measurement System (AMS) for Establishing Model Pitch and Roll Zero, and Performing Single Axis Angle Comparisons

    NASA Technical Reports Server (NTRS)

    Crawford, Bradley L.

    2007-01-01

    The angle measurement system (AMS) developed at NASA Langley Research Center (LaRC) is a system for many uses. It was originally developed to check taper fits in the wind tunnel model support system. The system was further developed to measure simultaneous pitch and roll angles using 3 orthogonally mounted accelerometers (3-axis). This 3-axis arrangement is used as a transfer standard from the calibration standard to the wind tunnel facility. It is generally used to establish model pitch and roll zero and performs the in-situ calibration on model attitude devices. The AMS originally used a laptop computer running DOS based software but has recently been upgraded to operate in a windows environment. Other improvements have also been made to the software to enhance its accuracy and add features. This paper will discuss the accuracy and calibration methodologies used in this system and some of the features that have contributed to its popularity.

  17. Evaluation of mandibular angle ostectomy using three-dimensional finite element analysis.

    PubMed

    Song, Jian; Zhu, Songsong; Luo, En; Hu, Jing; Feng, Ge

    2014-07-01

    This study was designed to investigate the stress and the displacement distributions of the mandible after mandibular angle ostectomy (MAO) by means of three-dimensional finite element analysis. On the basis of a female patient with a prominent angle of the mandible, the finite element models were generated by helical computed tomography and related software and were analyzed under muscle forces and 3 kinds of biting conditions, including intercuspal position (ICP), incisal clenching (INC), and right unilateral molar clenching (RMOL). The mandibular stress and displacement distributions were analyzed by Abaqus software. In the model of MAO, the increased stress and the decreased displacement was found in ICP, INC, and RMOL at the area of mandibular angle. The stress and the displacement increased in ICP and RMOL, whereas the others remained unchanged in INC at the area of mandibular condylar neck. The results of this study have shown that MAO could alter biomechanical characteristics in the operated mandible, which suggested that a greater hit on face may lead to a higher incidence rate of condyle fracture and a lower incidence rate of angle fracture after MAO.

  18. Atomistic modelling of scattering data in the Collaborative Computational Project for Small Angle Scattering (CCP-SAS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, Stephen J.; Wright, David W.; Zhang, Hailiang

    2016-10-14

    The capabilities of current computer simulations provide a unique opportunity to model small-angle scattering (SAS) data at the atomistic level, and to include other structural constraints ranging from molecular and atomistic energetics to crystallography, electron microscopy and NMR. This extends the capabilities of solution scattering and provides deeper insights into the physics and chemistry of the systems studied. Realizing this potential, however, requires integrating the experimental data with a new generation of modelling software. To achieve this, the CCP-SAS collaboration (http://www.ccpsas.org/) is developing open-source, high-throughput and user-friendly software for the atomistic and coarse-grained molecular modelling of scattering data. Robust state-of-the-artmore » molecular simulation engines and molecular dynamics and Monte Carlo force fields provide constraints to the solution structure inferred from the small-angle scattering data, which incorporates the known physical chemistry of the system. The implementation of this software suite involves a tiered approach in whichGenAppprovides the deployment infrastructure for running applications on both standard and high-performance computing hardware, andSASSIEprovides a workflow framework into which modules can be plugged to prepare structures, carry out simulations, calculate theoretical scattering data and compare results with experimental data.GenAppproduces the accessible web-based front end termedSASSIE-web, andGenAppandSASSIEalso make community SAS codes available. Applications are illustrated by case studies: (i) inter-domain flexibility in two- to six-domain proteins as exemplified by HIV-1 Gag, MASP and ubiquitin; (ii) the hinge conformation in human IgG2 and IgA1 antibodies; (iii) the complex formed between a hexameric protein Hfq and mRNA; and (iv) synthetic `bottlebrush' polymers.« less

  19. Atomistic modelling of scattering data in the Collaborative Computational Project for Small Angle Scattering (CCP-SAS).

    PubMed

    Perkins, Stephen J; Wright, David W; Zhang, Hailiang; Brookes, Emre H; Chen, Jianhan; Irving, Thomas C; Krueger, Susan; Barlow, David J; Edler, Karen J; Scott, David J; Terrill, Nicholas J; King, Stephen M; Butler, Paul D; Curtis, Joseph E

    2016-12-01

    The capabilities of current computer simulations provide a unique opportunity to model small-angle scattering (SAS) data at the atomistic level, and to include other structural constraints ranging from molecular and atomistic energetics to crystallography, electron microscopy and NMR. This extends the capabilities of solution scattering and provides deeper insights into the physics and chemistry of the systems studied. Realizing this potential, however, requires integrating the experimental data with a new generation of modelling software. To achieve this, the CCP-SAS collaboration (http://www.ccpsas.org/) is developing open-source, high-throughput and user-friendly software for the atomistic and coarse-grained molecular modelling of scattering data. Robust state-of-the-art molecular simulation engines and molecular dynamics and Monte Carlo force fields provide constraints to the solution structure inferred from the small-angle scattering data, which incorporates the known physical chemistry of the system. The implementation of this software suite involves a tiered approach in which GenApp provides the deployment infrastructure for running applications on both standard and high-performance computing hardware, and SASSIE provides a workflow framework into which modules can be plugged to prepare structures, carry out simulations, calculate theoretical scattering data and compare results with experimental data. GenApp produces the accessible web-based front end termed SASSIE-web , and GenApp and SASSIE also make community SAS codes available. Applications are illustrated by case studies: (i) inter-domain flexibility in two- to six-domain proteins as exemplified by HIV-1 Gag, MASP and ubiquitin; (ii) the hinge conformation in human IgG2 and IgA1 antibodies; (iii) the complex formed between a hexameric protein Hfq and mRNA; and (iv) synthetic 'bottlebrush' polymers.

  20. The leaf angle distribution of natural plant populations: assessing the canopy with a novel software tool.

    PubMed

    Müller-Linow, Mark; Pinto-Espinosa, Francisco; Scharr, Hanno; Rascher, Uwe

    2015-01-01

    Three-dimensional canopies form complex architectures with temporally and spatially changing leaf orientations. Variations in canopy structure are linked to canopy function and they occur within the scope of genetic variability as well as a reaction to environmental factors like light, water and nutrient supply, and stress. An important key measure to characterize these structural properties is the leaf angle distribution, which in turn requires knowledge on the 3-dimensional single leaf surface. Despite a large number of 3-d sensors and methods only a few systems are applicable for fast and routine measurements in plants and natural canopies. A suitable approach is stereo imaging, which combines depth and color information that allows for easy segmentation of green leaf material and the extraction of plant traits, such as leaf angle distribution. We developed a software package, which provides tools for the quantification of leaf surface properties within natural canopies via 3-d reconstruction from stereo images. Our approach includes a semi-automatic selection process of single leaves and different modes of surface characterization via polygon smoothing or surface model fitting. Based on the resulting surface meshes leaf angle statistics are computed on the whole-leaf level or from local derivations. We include a case study to demonstrate the functionality of our software. 48 images of small sugar beet populations (4 varieties) have been analyzed on the base of their leaf angle distribution in order to investigate seasonal, genotypic and fertilization effects on leaf angle distributions. We could show that leaf angle distributions change during the course of the season with all varieties having a comparable development. Additionally, different varieties had different leaf angle orientation that could be separated in principle component analysis. In contrast nitrogen treatment had no effect on leaf angles. We show that a stereo imaging setup together with the appropriate image processing tools is capable of retrieving the geometric leaf surface properties of plants and canopies. Our software package provides whole-leaf statistics but also a local estimation of leaf angles, which may have great potential to better understand and quantify structural canopy traits for guided breeding and optimized crop management.

  1. Automated CFD Database Generation for a 2nd Generation Glide-Back-Booster

    NASA Technical Reports Server (NTRS)

    Chaderjian, Neal M.; Rogers, Stuart E.; Aftosmis, Michael J.; Pandya, Shishir A.; Ahmad, Jasim U.; Tejmil, Edward

    2003-01-01

    A new software tool, AeroDB, is used to compute thousands of Euler and Navier-Stokes solutions for a 2nd generation glide-back booster in one week. The solution process exploits a common job-submission grid environment using 13 computers located at 4 different geographical sites. Process automation and web-based access to the database greatly reduces the user workload, removing much of the tedium and tendency for user input errors. The database consists of forces, moments, and solution files obtained by varying the Mach number, angle of attack, and sideslip angle. The forces and moments compare well with experimental data. Stability derivatives are also computed using a monotone cubic spline procedure. Flow visualization and three-dimensional surface plots are used to interpret and characterize the nature of computed flow fields.

  2. An Inviscid Computational Study of an X-33 Configuration at Hypersonic Speeds

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    1999-01-01

    This report documents the results of a study conducted to compute the inviscid longitudinal aerodynamic characteristics of a simplified X-33 configuration. The major components of the X-33 vehicle, namely the body, the canted fin, the vertical fin, and the body-flap, were simulated in the CFD (Computational Fluid Dynamic) model. The rear-ward facing surfaces at the base including the aerospike engine surfaces were not simulated. The FELISA software package consisting of an unstructured surface and volume grid generator and two inviscid flow solvers was used for this study. Computations were made for Mach 4.96, 6.0, and 10.0 with perfect gas air option, and for Mach 10 with equilibrium air option with flow condition of a typical point on the X-33 flight trajectory. Computations were also made with CF4 gas option at Mach 6.0 to simulate the CF4 tunnel flow condition. An angle of attack range of 12 to 48 deg was covered. The CFD results were compared with available wind tunnel data. Comparison was good at low angles of attack; at higher angles of attack (beyond 25 deg) some differences were found in the pitching moment. These differences progressively increased with increase in angle of attack, and are attributed to the viscous effects. However, the computed results showed the trends exhibited by the wind tunnel data.

  3. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  4. Development of digital interactive processing system for NOAA satellites AVHRR data

    NASA Astrophysics Data System (ADS)

    Gupta, R. K.; Murthy, N. N.

    The paper discusses the digital image processing system for NOAA/AVHRR data including Land applications - configured around VAX 11/750 host computer supported with FPS 100 Array Processor, Comtal graphic display and HP Plotting devices; wherein the system software for relational Data Base together with query and editing facilities, Man-Machine Interface using form, menu and prompt inputs including validation of user entries for data type and range; preprocessing software for data calibration, Sun-angle correction, Geometric Corrections for Earth curvature effect and Earth rotation offsets and Earth location of AVHRR image have been accomplished. The implemented image enhancement techniques such as grey level stretching, histogram equalization and convolution are discussed. The software implementation details for the computation of vegetative index and normalized vegetative index using NOAA/AVHRR channels 1 and 2 data together with output are presented; scientific background for such computations and obtainability of similar indices from Landsat/MSS data are also included. The paper concludes by specifying the further software developments planned and the progress envisaged in the field of vegetation index studies.

  5. Assessment of morphological and anatomical characteristics of mental foramen using cone beam computed tomography.

    PubMed

    Goyushov, Samir; Tözüm, Melek Didem; Tözüm, Tolga Fikret

    2018-05-25

    To determine the shape, position, vertical height, surrounding bone characteristics, and opening angle of mental foramen (MF) using dental cone beam computed tomography (CBCT). A retrospective study was performed on 663 patients. CBCT records analyzed for the shape, position, and surrounding bone measurements of the MF using Simplant 3D software (Hasselt, Belgium). Opening angle of MF was also assessed. Kruskal-Wallis and Mann-Whitney U tests were employed to test significant differences between parameters, genders and ages. All mental foramina were visualized. Regarding location, 49.2% of the MFs were located between first and second premolars, 7.7 distal and 39.7% coincident to the apex of the mandibular second premolar. The mean MF opening angle was 45.4° on the right side, and 45.9° on the left. There were no statistically differences between gender groups with regard to the opening angle degrees. This study may provide useful information about variations in the position, shape and size, angle of mental foramen, which may help the practitioners to perform safer mental nerve blocks and surgical procedures.

  6. SPICE: A Geometry Information System Supporting Planetary Mapping, Remote Sensing and Data Mining

    NASA Technical Reports Server (NTRS)

    Acton, C.; Bachman, N.; Semenov, B.; Wright, E.

    2013-01-01

    SPICE is an information system providing space scientists ready access to a wide assortment of space geometry useful in planning science observations and analyzing the instrument data returned therefrom. The system includes software used to compute many derived parameters such as altitude, LAT/LON and lighting angles, and software able to find when user-specified geometric conditions are obtained. While not a formal standard, it has achieved widespread use in the worldwide planetary science community

  7. Quantitative validation of a computer-aided maxillofacial planning system, focusing on soft tissue deformations.

    PubMed

    Nadjmi, Nasser; Defrancq, Ellen; Mollemans, Wouter; Hemelen, Geert Van; Bergé, Stefaan

    2014-01-01

    The aim of this study was to evaluate the accuracy of 3D soft tissue predictions generated by a computer-aided maxillofacial planning system in patients undergoing orthognathic surgery. Twenty patients with dentofacial dysmorphosis were treated with orthognathic surgery after a preoperative orthodontic treatment. Fourteen patients had an Angle Class II malocclusion; three patients had an Angle class III malocclusion, and three patients had an Angle Class I malocclusion. Skeletal asymmetry was observed in six patient. The surgeries were planned using the Maxilim software. Computer assisted surgical planning was transferred to the patient by digitally generated splints. The validation procedures were performed in the following steps: (1) Standardized registration of the pre- and postoperative Cone Beam CT volumes; (2) Automated adjustment of the bone-related planning to the actual operative bony displacement; (3) Simulation of soft tissue changes; (4) Calculation of the soft tissue differences between the predicted and the postoperative results by distance mapping. Eighty four percent of the mapped distances between the predicted and actual postoperative results measured between -2 mm and +2 mm. The mean absolute linear measurements between the predicted and actual postoperative surface was 1.18. Our study shows the overall prediction was dependent on neither the surgical procedures nor the dentofacial deformity type. Despite some shortcomings in the prediction of the final position of the lower lip and cheek area, this software promises a clinically acceptable soft tissue prediction for orthognathic surgical procedures.

  8. Proposals for the implementation of the variants of automatic control of the telescope AZT-2

    NASA Astrophysics Data System (ADS)

    Shavlovskyi, V. I.; Puha, S. P.; Vidmachenko, A. P.; Volovyk, D. V.; Puha, G. P.; Obolonskyi, V. O.; Kratko, O. O.; Stefurak, M. V.

    2018-05-01

    Based on the experience of astronomical observations, structural features and results of the review of the technical state of the mechanism of the telescope AZT-2 in the Main Astronomical Observatory of NAS of Ukraine, in 2012 it was decided to carry out works on its modernization. To this end, it was suggested that the telescope control system should consist of angle sensors on the time axis "alpha" and the axis "delta", personal computer (PC), corresponding software, power control unit, and rotation system of telescope. The angle sensor should be absolute, with a resolution of better than 10 angular minutes. The PC should perform the functions of data processing from the angle sensor, and control the power node. The developed software allows the operator to direct the telescope in an automatic mode, and to set the necessary parameters of the system. With using of PC, the power control node will directly control the engine of the rotation system.

  9. Development of spectral analysis math models and software program and spectral analyzer, digital converter interface equipment design

    NASA Technical Reports Server (NTRS)

    Hayden, W. L.; Robinson, L. H.

    1972-01-01

    Spectral analyses of angle-modulated communication systems is studied by: (1) performing a literature survey of candidate power spectrum computational techniques, determining the computational requirements, and formulating a mathematical model satisfying these requirements; (2) implementing the model on UNIVAC 1230 digital computer as the Spectral Analysis Program (SAP); and (3) developing the hardware specifications for a data acquisition system which will acquire an input modulating signal for SAP. The SAP computational technique uses extended fast Fourier transform and represents a generalized approach for simple and complex modulating signals.

  10. Application of computer-aided design osteotomy template for treatment of cubitus varus deformity in teenagers: a pilot study.

    PubMed

    Zhang, Yuan Z; Lu, Sheng; Chen, Bin; Zhao, Jian M; Liu, Rui; Pei, Guo X

    2011-01-01

    Treatment of cubitus varus deformity from a malunited fracture is a challenge. Anatomically accurate correction is the key to obtaining good functional outcomes after corrective osteotomy. The aim of this study was to attempt to increase the accuracy of treatment by use of 3-dimensional (3D) computer-aided design. We describe a novel method for ensuring an accurate osteotomy method in the treatment of cubitus varus deformity in teenagers by means of 3D reconstruction and reverse engineering. Between January 2006 and May 2008, 12 male and 6 female patients with cubitus varus deformities underwent scanning with spiral computed tomography (CT) preoperatively. The mean age was 15.7 years, ranging from 13 to 19 years. Three-dimensional CT image data of the affected and contralateral normal bones of cubitus were transferred to a computer workstation. Three-dimensional models of cubitus were reconstructed by use of MIMICS software. The 3D models were then processed by Imageware software. An osteotomy template that best fitted the angle and range of osteotomy was "reversely" built from the 3D model. These templates were manufactured by a rapid prototyping machine. The osteotomy templates guide the osteotomy of cubitus. An accurate angle of osteotomy was confirmed by postoperative radiography. After 12 to 24 months' follow-up, the mean postoperative carrying angle in 18 patients with cubitus varus deformity was 7.3° (range, 5° to 11°), with a mean correction of 21.9° (range, 12° to 41°). The patient-specific template technique is easy to use, can simplify the surgical act, and generates highly accurate osteotomy in cubitus varus deformity in teenagers. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Multiple-Flat-Panel System Displays Multidimensional Data

    NASA Technical Reports Server (NTRS)

    Gundo, Daniel; Levit, Creon; Henze, Christopher; Sandstrom, Timothy; Ellsworth, David; Green, Bryan; Joly, Arthur

    2006-01-01

    The NASA Ames hyperwall is a display system designed to facilitate the visualization of sets of multivariate and multidimensional data like those generated in complex engineering and scientific computations. The hyperwall includes a 77 matrix of computer-driven flat-panel video display units, each presenting an image of 1,280 1,024 pixels. The term hyperwall reflects the fact that this system is a more capable successor to prior computer-driven multiple-flat-panel display systems known by names that include the generic term powerwall and the trade names PowerWall and Powerwall. Each of the 49 flat-panel displays is driven by a rack-mounted, dual-central-processing- unit, workstation-class personal computer equipped with a hig-hperformance graphical-display circuit card and with a hard-disk drive having a storage capacity of 100 GB. Each such computer is a slave node in a master/ slave computing/data-communication system (see Figure 1). The computer that acts as the master node is similar to the slave-node computers, except that it runs the master portion of the system software and is equipped with a keyboard and mouse for control by a human operator. The system utilizes commercially available master/slave software along with custom software that enables the human controller to interact simultaneously with any number of selected slave nodes. In a powerwall, a single rendering task is spread across multiple processors and then the multiple outputs are tiled into one seamless super-display. It must be noted that the hyperwall concept subsumes the powerwall concept in that a single scene could be rendered as a mosaic image on the hyperwall. However, the hyperwall offers a wider set of capabilities to serve a different purpose: The hyperwall concept is one of (1) simultaneously displaying multiple different but related images, and (2) providing means for composing and controlling such sets of images. In place of elaborate software or hardware crossbar switches, the hyperwall concept substitutes reliance on the human visual system for integration, synthesis, and discrimination of patterns in complex and high-dimensional data spaces represented by the multiple displayed images. The variety of multidimensional data sets that can be displayed on the hyperwall is practically unlimited. For example, Figure 2 shows a hyperwall display of surface pressures and streamlines from a computational simulation of airflow about an aerospacecraft at various Mach numbers and angles of attack. In this display, Mach numbers increase from left to right and angles of attack increase from bottom to top. That is, all images in the same column represent simulations at the same Mach number, while all images in the same row represent simulations at the same angle of attack. The same viewing transformations and the same mapping from surface pressure to colors were used in generating all the images.

  12. A fast and accurate surface plasmon resonance system

    NASA Astrophysics Data System (ADS)

    Espinosa Sánchez, Y. M.; Luna Moreno, D.; Noé Arias, E.; Garnica Campos, G.

    2012-10-01

    In this work we propose a Surface Plasmon Resonance (SPR) system driven by Labview software which produces a fast, simple and accuracy measurements of samples. The system takes 2000 data in a range of 20 degrees in 20 seconds and 0.01 degrees of resolution. All the information is sent from the computer to the microcontroller as an array of bytes in hexadecimal format to be analyzed. Besides to using the system in SPR measurement is possible to make measurement of the critic angle, and Brewster angle using the Abeles method.

  13. A Software Architecture for a Small Autonomous Underwater Vehicle Navigation System

    DTIC Science & Technology

    1993-06-01

    angle consistent with system accuracy objectives for the interim SANS system must be quantified. 12 DEPTH CHAC oCLIMB ANGLE HORIZONTAL DISTANCE Figure...Figure 4.1 illustrates the hardware interface. COMPUTER (ESP-8o80) D IG IT A L B I N A R GYRO SIGNAL BINARY BINARY HEADING DATA "\\DATA DEPTH /RS-232...Mode 3 of the 82C54 provides a square wave through any of the 3 counters in the 82C54. An initial count N is written to the counter control register

  14. A feasability study of color flow doppler vectorization for automated blood flow monitoring.

    PubMed

    Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D

    2017-12-01

    An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.

  15. The combined control algorithm for large-angle maneuver of HITSAT-1 small satellite

    NASA Astrophysics Data System (ADS)

    Zhaowei, Sun; Yunhai, Geng; Guodong, Xu; Ping, He

    2004-04-01

    The HITSAT-1 is the first small satellite developed by Harbin Institute of Technology (HIT) whose mission objective is to test several pivotal techniques. The large angle maneuver control is one of the pivotal techniques of HITSAT-1 and the instantaneous Eulerian axis control algorithm (IEACA) has been applied. Because of using the reaction wheels and magnetorquer as the control actuators, the combined control algorithm has been adopted during the large-angle maneuver course. The computer simulation based on the MATRIX×6.0 software has finished and the results indicated that the combined control algorithm reduced the reaction wheel speeds obviously, and the IEACA algorithm has the advantages of simplicity and efficiency.

  16. Computer-aided evaluation of low-dose and low-contrast agent third-generation dual-source CT angiography prior to transcatheter aortic valve implantation (TAVI).

    PubMed

    Dankerl, Peter; Hammon, Matthias; Seuss, Hannes; Tröbs, Monique; Schuhbaeck, Annika; Hell, Michaela M; Cavallaro, Alexander; Achenbach, Stephan; Uder, Michael; Marwan, Mohamed

    2017-05-01

    To evaluate the performance of computer-aided evaluation software for a comprehensive workup of patients prior to transcatheter aortic valve implantation (TAVI) using low-contrast agent and low radiation dose third-generation dual-source CT angiography. We evaluated 30 consecutive patients scheduled for TAVI. All patients underwent ECG-triggered high-pitch dual-source CT angiography of the aortic root and aorta with a standardized contrast agent volume (30 ml Imeron350, flow rate 4 ml/s) and low-dose (100 kv/350 mAs) protocol. An expert (10 years of experience) manually evaluated aortic root and iliac access dimensions (distance between coronary ostia and aortic annulus, minimal/maximal diameters and area-derived diameter of the aortic annulus) and best CT-predicted fluoroscopic projection angle as the reference standard. Utilizing computer-aided software (syngo.via), the same pre-TAVI workup was performed and compared to the reference standard. Mean CTDI[Formula: see text] was 3.46 mGy and mean DLP 217.6 ± 12.1 mGy cm, corresponding to a mean effective dose of 3.7 ± 0.2 mSv. Computer-aided evaluation was successful in all but one patient. Compared to the reference standard, Bland-Altman analysis indicated very good agreement for the distances between aortic annulus and coronary ostia (RCA: mean difference 0.8 mm; 95 % CI 0.4-1.2 mm; LM: mean difference 0.9 mm; 95 % CI 0.5-1.3 mm); however, we demonstrated a systematic overestimation of annulus- derived diameter using the software (mean difference 44.4 mm[Formula: see text]; 95 % CI 30.4-58.3 mm[Formula: see text]). Based on respective annulus dimensions, the recommended prosthesis size (Edwards SAPIEN 3) matched in 26 out of the 29 patients (90 %). CT-derived fluoroscopic projection angles showed an excellent agreement for both methods. Out of 58 iliac arteries, 15 (25 %) arteries could not be segmented by the software. Preprocessing time of the software was 71 ± 11 s (range 51-96 s), and reading time with the software was 118 ± 31 s (range 68-201 s). In the workup of pre-TAVI CT angiography, computer-aided evaluation of low-contrast, low-dose examinations is feasible with good agreement and quick reading time. However, a systematic overestimation of the aortic annulus area is observed.

  17. Predicting broadband noise from a stator vane of a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Hanson, Donald B. (Inventor)

    2002-01-01

    A computer-implemented model of fan section of a gas turbine engine accounts for the turbulence in the gas flow emanating from the rotor assembly and impinging upon an inlet to the stator vane cascade. The model allows for user-input variations in the sweep and/or lean angles for the stator vanes. The model determines the resulting acoustic response of the fan section as a function of the turbulence and the lean and/or sweep angles of the vanes. The model may be embodied in software that is rapidly executed in a computer. This way, an optimum arrangement in terms of fan noise reduction is quickly determined for the stator vane lean and sweep physical positioning in the fan section of a gas turbine engine.

  18. Adjoint Airfoil Optimization of Darrieus-Type Vertical Axis Wind Turbine

    NASA Astrophysics Data System (ADS)

    Fuchs, Roman; Nordborg, Henrik

    2012-11-01

    We present the feasibility of using an adjoint solver to optimize the torque of a Darrieus-type vertical axis wind turbine (VAWT). We start with a 2D cross section of a symmetrical airfoil and restrict us to low solidity ratios to minimize blade vortex interactions. The adjoint solver of the ANSYS FLUENT software package computes the sensitivities of airfoil surface forces based on a steady flow field. Hence, we find the torque of a full revolution using a weighted average of the sensitivities at different wind speeds and angles of attack. The weights are computed analytically, and the range of angles of attack is given by the tip speed ratio. Then the airfoil geometry is evolved, and the proposed methodology is evaluated by transient simulations.

  19. Three-dimensional perspective software for representation of digital imagery data. [Olympic National Park, Washington

    NASA Technical Reports Server (NTRS)

    Junkin, B. G.

    1980-01-01

    A generalized three dimensional perspective software capability was developed within the framework of a low cost computer oriented geographically based information system using the Earth Resources Laboratory Applications Software (ELAS) operating subsystem. This perspective software capability, developed primarily to support data display requirements at the NASA/NSTL Earth Resources Laboratory, provides a means of displaying three dimensional feature space object data in two dimensional picture plane coordinates and makes it possible to overlay different types of information on perspective drawings to better understand the relationship of physical features. An example topographic data base is constructed and is used as the basic input to the plotting module. Examples are shown which illustrate oblique viewing angles that convey spatial concepts and relationships represented by the topographic data planes.

  20. Testing of CMA-2000 Microwave Landing System (MLS) airborne receiver

    NASA Astrophysics Data System (ADS)

    Labreche, L.; Murfin, A. J.

    1989-09-01

    Microwave landing system (MLS) is a precision approach and landing guidance system which provides position information and various air to ground data. Position information is provided on a wide coverage sector and is determined by an azimuth angle measurement, an elevation angle measurement, and a range measurement. MLS performance standards and testing of the MLS airborne receiver is mainly governed by Technical Standard Order TSO-C104 issued by the Federal Aviation Administration. This TSO defines detailed test procedures for use in determining the required performance under standard and stressed conditions. It also imposes disciplines on software development and testing procedures. Testing performed on the CMA-2000 MLS receiver and methods used in its validation are described. A computer automated test system has been developed to test for compliance with RTCA/DO-177 Minimum Operation Performance Standards. Extensive software verification and traceability tests designed to ensure compliance with RTCA/DO-178 are outlined.

  1. A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bharoto; Putra, Edy Giri Rachman

    2010-06-22

    The original main control system of the 36 meter small-angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two-directional movement of a neutron beam stopper, forward-backward movement of a 2Dmore » position sensitive detector (2D-PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user-friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.« less

  2. A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bharoto,; Putra, Edy Giri Rachman

    2010-06-22

    The original main control system of the 36 meter small‐angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two‐directional movement of a neutron beam stopper, forward‐backward movement of a 2Dmore » position sensitive detector (2D‐PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user‐friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.« less

  3. Assessment of lumbosacral kyphosis in spondylolisthesis: a computer-assisted reliability study of six measurement techniques

    PubMed Central

    Glavas, Panagiotis; Mac-Thiong, Jean-Marc; Parent, Stefan; de Guise, Jacques A.

    2008-01-01

    Although recognized as an important aspect in the management of spondylolisthesis, there is no consensus on the most reliable and optimal measure of lumbosacral kyphosis (LSK). Using a custom computer software, four raters evaluated 60 standing lateral radiographs of the lumbosacral spine during two sessions at a 1-week interval. The sample size consisted of 20 normal, 20 low and 20 high grade spondylolisthetic subjects. Six parameters were included for analysis: Boxall’s slip angle, Dubousset’s lumbosacral angle (LSA), the Spinal Deformity Study Group’s (SDSG) LSA, dysplastic SDSG LSA, sagittal rotation (SR), kyphotic Cobb angle (k-Cobb). Intra- and inter-rater reliability for all parameters was assessed using intra-class correlation coefficients (ICC). Correlations between parameters and slip percentage were evaluated with Pearson coefficients. The intra-rater ICC’s for all the parameters ranged between 0.81 and 0.97 and the inter-rater ICC’s were between 0.74 and 0.98. All parameters except sagittal rotation showed a medium to large correlation with slip percentage. Dubousset’s LSA and the k-Cobb showed the largest correlations (r = −0.78 and r = −0.50, respectively). SR was associated with the weakest correlation (r = −0.10). All other parameters had medium correlations with percent slip (r = 0.31–0.43). All measurement techniques provided excellent inter- and intra-rater reliability. Dubousset’s LSA showed the strongest correlation with slip grade. This parameter can be used in the clinical setting with PACS software capabilities to assess LSK. A computer-assisted technique is recommended in order to increase the reliability of the measurement of LSK in spondylolisthesis. PMID:19015898

  4. Computational Study of a McDonnell Douglas Single-Stage-to-Orbit Vehicle Concept for Aerodynamic Analysis

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    1996-01-01

    This paper presents the results of a computational flow analysis of the McDonnell Douglas single-stage-to-orbit vehicle concept designated as the 24U. This study was made to determine the aerodynamic characteristics of the vehicle with and without body flaps over an angle of attack range of 20-40 deg. Computations were made at a flight Mach number of 20 at 200,000 ft. altitude with equilibrium air, and a Mach number of 6 with CF4 gas. The software package FELISA (Finite Element Langley imperial College Sawansea Ames) was used for all the computations. The FELISA software consists of unstructured surface and volume grid generators, and inviscid flow solvers with (1) perfect gas option for subsonic, transonic, and low supersonic speeds, and (2) perfect gas, equilibrium air, and CF4 options for hypersonic speeds. The hypersonic flow solvers with equilibrium air and CF4 options were used in the present studies. Results are compared with other computational results and hypersonic CF4 tunnel test data.

  5. Modeling Magnetic Properties in EZTB

    NASA Technical Reports Server (NTRS)

    Lee, Seungwon; vonAllmen, Paul

    2007-01-01

    A software module that calculates magnetic properties of a semiconducting material has been written for incorporation into, and execution within, the Easy (Modular) Tight-Binding (EZTB) software infrastructure. [EZTB is designed to model the electronic structures of semiconductor devices ranging from bulk semiconductors, to quantum wells, quantum wires, and quantum dots. EZTB implements an empirical tight-binding mathematical model of the underlying physics.] This module can model the effect of a magnetic field applied along any direction and does not require any adjustment of model parameters. The module has thus far been applied to study the performances of silicon-based quantum computers in the presence of magnetic fields and of miscut angles in quantum wells. The module is expected to assist experimentalists in fabricating a spin qubit in a Si/SiGe quantum dot. This software can be executed in almost any Unix operating system, utilizes parallel computing, can be run as a Web-portal application program. The module has been validated by comparison of its predictions with experimental data available in the literature.

  6. Visual comparison testing of automotive paint simulation

    NASA Astrophysics Data System (ADS)

    Meyer, Gary; Fan, Hua-Tzu; Seubert, Christopher; Evey, Curtis; Meseth, Jan; Schnackenberg, Ryan

    2015-03-01

    An experiment was performed to determine whether typical industrial automotive color paint comparisons made using real physical samples could also be carried out using a digital simulation displayed on a calibrated color television monitor. A special light booth, designed to facilitate evaluation of the car paint color with reflectance angle, was employed in both the real and virtual color comparisons. Paint samples were measured using a multi-angle spectrophotometer and were simulated using a commercially available software package. Subjects performed the test quicker using the computer graphic simulation, and results indicate that there is only a small difference between the decisions made using the light booth and the computer monitor. This outcome demonstrates the potential of employing simulations to replace some of the time consuming work with real physical samples that still characterizes material appearance work in industry.

  7. Tokamak-independent software analysis suite for multi-spectral line-polarization MSE diagnostics

    DOE PAGES

    Scott, S. D.; Mumgaard, R. T.

    2016-07-20

    A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (mse) diagnostics. The software supports multi-spectral line-polarization mse diagnostics which simultaneously measure emission at the mse σ and π lines as well as at two "background" wavelengths that are displaced from the mse spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially polarized background light at the σ and π wavelengths even in situations where the background light changes rapidly in time and space, a distinct improvement over traditional "time-interpolation" background estimation. The signal amplitude at many frequencies is computed using amore » numerical-beat algorithm which allows the retardance of the mse photo-elastic modulators (pem's) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to pem retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the mse diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge. As a result, the software suite is modular, parallelized, and portable to other facilities.« less

  8. Tokamak-independent software analysis suite for multi-spectral line-polarization MSE diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, S. D.; Mumgaard, R. T.

    A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (mse) diagnostics. The software supports multi-spectral line-polarization mse diagnostics which simultaneously measure emission at the mse σ and π lines as well as at two "background" wavelengths that are displaced from the mse spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially polarized background light at the σ and π wavelengths even in situations where the background light changes rapidly in time and space, a distinct improvement over traditional "time-interpolation" background estimation. The signal amplitude at many frequencies is computed using amore » numerical-beat algorithm which allows the retardance of the mse photo-elastic modulators (pem's) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to pem retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the mse diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge. As a result, the software suite is modular, parallelized, and portable to other facilities.« less

  9. Accuracy of three-dimensional soft tissue prediction for Le Fort I osteotomy using Dolphin 3D software: a pilot study.

    PubMed

    Resnick, C M; Dang, R R; Glick, S J; Padwa, B L

    2017-03-01

    Three-dimensional (3D) soft tissue prediction is replacing two-dimensional analysis in planning for orthognathic surgery. The accuracy of different computational models to predict soft tissue changes in 3D, however, is unclear. A retrospective pilot study was implemented to assess the accuracy of Dolphin 3D software in making these predictions. Seven patients who had a single-segment Le Fort I osteotomy and had preoperative (T 0 ) and >6-month postoperative (T 1 ) cone beam computed tomography (CBCT) scans and 3D photographs were included. The actual skeletal change was determined by subtracting the T 0 from the T 1 CBCT. 3D photographs were overlaid onto the T 0 CBCT and virtual skeletal movements equivalent to the achieved repositioning were applied using Dolphin 3D planner. A 3D soft tissue prediction (T P ) was generated and differences between the T P and T 1 images (error) were measured at 14 points and at the nasolabial angle. A mean linear prediction error of 2.91±2.16mm was found. The mean error at the nasolabial angle was 8.1±5.6°. In conclusion, the ability to accurately predict 3D soft tissue changes after Le Fort I osteotomy using Dolphin 3D software is limited. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Use of the iPhone for radiographic evaluation of hallux valgus.

    PubMed

    Ege, Tolga; Kose, Ozkan; Koca, Kenan; Demiralp, Bahtiyar; Basbozkurt, Mustafa

    2013-02-01

    The purpose of this study was to compare the measurements made using a smartphone accelerometer and computerized measurements as a reference in a series of 32 hallux valgus patients. Two observers used an iPhone to measure the hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (of anteroposterior foot radiographs in 32 patients with symptomatic hallux valgus on a computer screen. Digital angular measurements on the computer were set as the reference standard for analysis and comparison. The difference between computerized measurements and all iPhone measurements, and the difference between the first and second iPhone measurements for each observer were calculated. Inter- and intraobserver reliability of the smartphone measurement method was also tested. The variability of all measurements was similar for the iPhone and the computer-assisted techniques. The concordance between iPhone and computer-assisted angular measurements was excellent for the HVA, IMA, and DMAA. The maximum mean difference between the two techniques was 1.25 ± 1.02° for HVA, 0.92 ± 0.92° for IMA, and 1.10 ± 0.82° for DMAA. The interobserver reliability was excellent for HVA, IMA, and DMAA. The maximum mean difference between observers was 1.31 ± 0.89° for HVA, 0.90 ± 0.92° for IMA, and 0.78 ± 0.87° for DMAA. The intraobserver reliability was excellent for HVA, IMA, and DMAA. We conclude that the Hallux Angles software for the iPhone can be used for measurement of hallux valgus angles in clinical practice and even for research purposes. It is an accurate and reproducible method.

  11. Introducing Quantum Mechanics into General Chemistry

    NASA Astrophysics Data System (ADS)

    Popkowski, Iwona; Bascal, Hafed

    2008-10-01

    Periodicity has long been recognized as the tool that chemists can use to bring some order to investigating the chemistry of more than one hundred elements. Such studies provide useful tools for understanding a wide array of chemical principles. The advances in computational chemistry make it possible to study and teach such trends with hands on approach. In this study we utilize recently acquired software Spartan Pro to illustrate theoretical measurements of bond length, bond angle and dipole as compared to experimental data. We constructed a matrix of values obtained from the theoretical calculations and obtained trends in bond length, bond angle and dipoles for the several periodic groups.

  12. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    PubMed

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and ≤5.3° for the sacral angles. The variability in the linear measurements (distances) was <4 mm. The variance of the measures was 1.7 and 2.6 times greater, respectively, for the angular and linear measures between the inter- and intrameasurer reliability. The image quality positively influenced the intermeasurer reliability especially for the proximal thoracic Cobb angle, T10-L2 lordosis, sacral slope and L5 seating. The accuracy study revealed that on average the difference in the angular measures was < 2° for the Cobb angles, and < 4° for the other angles, except T2-T12 kyphosis (5.3°). The linear measures were all <3.5 mm difference on average. The majority of the measures, which were analyzed in this study demonstrated good to excellent reliability and accuracy. The novel semiautomatic measurement software can be recommended for use for clinical, research or multicenter study purposes.

  13. Inviscid Flow Computations of Two '07 Mars Lander Aeroshell Configurations Over a Mach Number Range of 2 to 24

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    2001-01-01

    This report documents the results of an inviscid computational study conducted on two aeroshell configurations for a proposed '07 Mars Lander. The aeroshell configurations are asymmetric due to the presence of the tabs at the maximum diameter location. The purpose of these tabs was to change the pitching moment characteristics so that the aeroshell will trim at a non-zero angle of attack and produce a lift-to-drag ratio of approximately -0.25. This is required in the guidance of the vehicle on its trajectory. One of the two configurations is called the shelf and the other is called the tab. The unstructured grid software FELISA with the equilibrium Mars gas option was used for these computations. The computations were done for six points on a preliminary trajectory of the '07 Mars Lander at nominal Mach numbers of 2, 3, 5, 10, 15, and 24. Longitudinal aerodynamic characteristics namely lift, drag, and pitching moment were computed for 10, 15, and 20 degrees angles of attack. The results indicated that the two configurations have aerodynamic characteristics that have very similar aerodynamic characteristics, and provide the desired trim LID of approximately -0.25.

  14. A precise goniometer/tensiometer using a low cost single-board computer

    NASA Astrophysics Data System (ADS)

    Favier, Benoit; Chamakos, Nikolaos T.; Papathanasiou, Athanasios G.

    2017-12-01

    Measuring the surface tension and the Young contact angle of a droplet is extremely important for many industrial applications. Here, considering the booming interest for small and cheap but precise experimental instruments, we have constructed a low-cost contact angle goniometer/tensiometer, based on a single-board computer (Raspberry Pi). The device runs an axisymmetric drop shape analysis (ADSA) algorithm written in Python. The code, here named DropToolKit, was developed in-house. We initially present the mathematical framework of our algorithm and then we validate our software tool against other well-established ADSA packages, including the commercial ramé-hart DROPimage Advanced as well as the DropAnalysis plugin in ImageJ. After successfully testing for various combinations of liquids and solid surfaces, we concluded that our prototype device would be highly beneficial for industrial applications as well as for scientific research in wetting phenomena compared to the commercial solutions.

  15. Real-time distortion correction for visual inspection systems based on FPGA

    NASA Astrophysics Data System (ADS)

    Liang, Danhua; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin

    2008-03-01

    Visual inspection is a kind of new technology based on the research of computer vision, which focuses on the measurement of the object's geometry and location. It can be widely used in online measurement, and other real-time measurement process. Because of the defects of the traditional visual inspection, a new visual detection mode -all-digital intelligent acquisition and transmission is presented. The image processing, including filtering, image compression, binarization, edge detection and distortion correction, can be completed in the programmable devices -FPGA. As the wide-field angle lens is adopted in the system, the output images have serious distortion. Limited by the calculating speed of computer, software can only correct the distortion of static images but not the distortion of dynamic images. To reach the real-time need, we design a distortion correction system based on FPGA. The method of hardware distortion correction is that the spatial correction data are calculated first under software circumstance, then converted into the address of hardware storage and stored in the hardware look-up table, through which data can be read out to correct gray level. The major benefit using FPGA is that the same circuit can be used for other circularly symmetric wide-angle lenses without being modified.

  16. Changes in Pelvic Incidence, Pelvic Tilt, and Sacral Slope in Situations of Pelvic Rotation.

    PubMed

    Jin, Hai-Ming; Xu, Dao-Liang; Xuan, Jun; Chen, Jiao-Xiang; Chen, Kai; Goswami, Amit; Chen, Yu; Kong, Qiu-Yan; Wang, Xiang-Yang

    2017-08-01

    Digitally reconstructed radiograph-based study. Using a computer-based method to determine what degree of pelvic rotation is acceptable for measuring the pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). The effectiveness of a geometrical formula used to calculate the angle of pelvic rotation proposed in a previous article was assessed. It is unclear whether PI, PT, and SS are valid with pelvic rotation while acquiring a radiograph. Ten 3-dimensionally reconstructed models were established with software and placed in a neutral orientation to orient all of the bones in a standing position. Next, 140 digitally reconstructed radiographs were obtained by rotating the models around the longitudinal axis of each pelvis in the software from 0 to 30 degrees at 2.5-degree intervals. PI, PT, and SS were measured. The rotation angle was considered to be acceptable when the change in the measured angle (compared with the "correct" position) was <6 degrees. The rotation angle (α) on the images was calculated by a geometrical formula. Consistency between the measured value and the set angle was assessed. The acceptable maximum angle of rotation for reliable measurements of PI was 17.5 degrees, and the changes in PT and SS were within an acceptable range (<6 degrees) when the pelvic rotation increased from 0 to 30 degrees. The effectiveness of the geometrical formula was shown by the consistency between the set and the calculated rotation angles of the pelvis (intraclass correlation coefficient=0.99). Our study provides insight into the influence of pelvic rotation on the PI, PT, and SS. PI changes with pelvic rotation. The acceptable maximum angle for reliable values of PI, PT, and SS was 17.5 degrees, and the rotation angle of the pelvis on a lateral spinopelvic radiograph can be calculated reliably.

  17. Establishing cephalometric landmarks for the translational study of Le Fort-based facial transplantation in Swine: enhanced applications using computer-assisted surgery and custom cutting guides.

    PubMed

    Santiago, Gabriel F; Susarla, Srinivas M; Al Rakan, Mohammed; Coon, Devin; Rada, Erin M; Sarhane, Karim A; Shores, Jamie T; Bonawitz, Steven C; Cooney, Damon; Sacks, Justin; Murphy, Ryan J; Fishman, Elliot K; Brandacher, Gerald; Lee, W P Andrew; Liacouras, Peter; Grant, Gerald; Armand, Mehran; Gordon, Chad R

    2014-05-01

    Le Fort-based, maxillofacial allotransplantation is a reconstructive alternative gaining clinical acceptance. However, the vast majority of single-jaw transplant recipients demonstrate less-than-ideal skeletal and dental relationships, with suboptimal aesthetic harmony. The purpose of this study was to investigate reproducible cephalometric landmarks in a large-animal model, where refinement of computer-assisted planning, intraoperative navigational guidance, translational bone osteotomies, and comparative surgical techniques could be performed. Cephalometric landmarks that could be translated into the human craniomaxillofacial skeleton, and that would remain reliable following maxillofacial osteotomies with midfacial alloflap inset, were sought on six miniature swine. Le Fort I- and Le Fort III-based alloflaps were harvested in swine with osteotomies, and all alloflaps were either autoreplanted or transplanted. Cephalometric analyses were performed on lateral cephalograms preoperatively and postoperatively. Critical cephalometric data sets were identified with the assistance of surgical planning and virtual prediction software and evaluated for reliability and translational predictability. Several pertinent landmarks and human analogues were identified, including pronasale, zygion, parietale, gonion, gnathion, lower incisor base, and alveolare. Parietale-pronasale-alveolare and parietale-pronasale-lower incisor base were found to be reliable correlates of sellion-nasion-A point angle and sellion-nasion-B point angle measurements in humans, respectively. There is a set of reliable cephalometric landmarks and measurement angles pertinent for use within a translational large-animal model. These craniomaxillofacial landmarks will enable development of novel navigational software technology, improve cutting guide designs, and facilitate exploration of new avenues for investigation and collaboration.

  18. Applications of cone-beam computed tomography to assess the effects of labial crown morphologies and collum angles on torque for maxillary anterior teeth.

    PubMed

    Kong, Wei-Dong; Ke, Jun-Yu; Hu, Xiang-Quan; Zhang, Wu; Li, Shu-Shu; Feng, Yi

    2016-11-01

    Currently, cone-beam computed tomography (CBCT) has been widely used because of its capacity to evaluate the anatomic structures of the maxilla, mandible, and teeth in 3 dimensions. However, articles about the use of CBCT to evaluate the relationships between the morphology of individual teeth and torque expression remain rare. In this study, we aimed to determine the influence of labial crown morphologies and collum angles on torque for maxillary anterior teeth using CBCT. A total of 206 extracted maxillary anterior teeth were selected to establish scanning models using dental wax, and they were scanned by CBCT. Three-dimensionally reconstructed images and median sagittal sections of the teeth were digitized and analyzed with AutoCAD software (Autodesk, San Rafael, Calif). The angle α, formed by the intersection of the tangent at a certain vertical height on the labial surface from the incisal edge with the crown long axis, and the collum angle, were measured. The variations in angle α at different heights from the incisal edge for the same type of tooth were statistically significantly different (P <0.001). Moreover, the variations between collum angles and 0° for any type of maxillary anterior tooth were statistically significant (P <0.01). This study suggested that there are great differences in labial crown morphologies and collum angles for maxillary anterior teeth between persons, indicating that the morphologies of these teeth do play important roles in torque variations. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  19. Three-dimensional path planning software-assisted transjugular intrahepatic portosystemic shunt: a technical modification.

    PubMed

    Tsauo, Jiaywei; Luo, Xuefeng; Ye, Linchao; Li, Xiao

    2015-06-01

    This study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS). 3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate the angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients. Failure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures. Adjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.

  20. Computational Analysis of Human Blood Flow

    NASA Astrophysics Data System (ADS)

    Panta, Yogendra; Marie, Hazel; Harvey, Mark

    2009-11-01

    Fluid flow modeling with commercially available computational fluid dynamics (CFD) software is widely used to visualize and predict physical phenomena related to various biological systems. In this presentation, a typical human aorta model was analyzed assuming the blood flow as laminar with complaint cardiac muscle wall boundaries. FLUENT, a commercially available finite volume software, coupled with Solidworks, a modeling software, was employed for the preprocessing, simulation and postprocessing of all the models.The analysis mainly consists of a fluid-dynamics analysis including a calculation of the velocity field and pressure distribution in the blood and a mechanical analysis of the deformation of the tissue and artery in terms of wall shear stress. A number of other models e.g. T branches, angle shaped were previously analyzed and compared their results for consistency for similar boundary conditions. The velocities, pressures and wall shear stress distributions achieved in all models were as expected given the similar boundary conditions. The three dimensional time dependent analysis of blood flow accounting the effect of body forces with a complaint boundary was also performed.

  1. 2015 USAFA Research Report: Discover Falcon Innovation

    DTIC Science & Technology

    2015-01-01

    delivery system deployed from a canister. Their solution allows the canister to release hundreds of the sensors at the right angle and in waves so that...Computer Science at the Air Force Academy. The center develops sensors for the aircraft – it uses commercially available UAVs known as Haulers – to allow... sensors and software development, said Tim McCarthy, one of the co-founders of Aspect Robotics. During the last semester, Academy cadets in the

  2. BAM/DASS: Data Analysis Software for Sub-Microarcsecond Astrometry Device

    NASA Astrophysics Data System (ADS)

    Gardiol, D.; Bonino, D.; Lattanzi, M. G.; Riva, A.; Russo, F.

    2010-12-01

    The INAF - Osservatorio Astronomico di Torino is part of the Data Processing and Analysis Consortium (DPAC) for Gaia, a cornerstone mission of the European Space Agency. Gaia will perform global astrometry by means of two telescopes looking at the sky along two different lines of sight oriented at a fixed angle, also called basic angle. Knowledge of the basic angle fluctuations at the sub-microarcsecond level over periods of the order of the minute is crucial to reach the mission goals. A specific device, the Basic Angle Monitoring, will be dedicated to this purpose. We present here the software system we are developing to analyze the BAM data and recover the basic angle variations. This tool is integrated into the whole DPAC data analysis software.

  3. Scalp marking for a craniotomy using a laser pointer during preoperative computed tomographic imaging: technical note.

    PubMed

    Kubo, S; Nakata, H; Sugauchi, Y; Yokota, N; Yoshimine, T

    2000-05-01

    The preoperative localization of superficial intracranial lesions is often necessary for accurate burr hole placement or craniotomy siting. It is not always easy, however, to localize the lesions over the scalp working only from computed tomographic images. We developed a simple method for such localization using a laser pointer during the preoperative computed tomographic examination. The angle of incidence, extending from a point on the scalp to the center of the computed tomographic image, is measured by the software included with the scanner. In the gantry, at the same angle as on the image, a laser is beamed from a handmade projector onto the patient's scalp toward the center of the gantry. The point illuminated on the patient's head corresponds to that on the image. The device and the method are described in detail herein. We applied this technique to mark the area for the craniotomy before surgery in five patients with superficial brain tumors. At the time of surgery, it was confirmed that the tumors were circumscribed precisely. The technique is easy to perform and useful in the preoperative planning for a craniotomy. In addition, the device is easily constructed and inexpensive.

  4. Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsauo, Jiaywei, E-mail: 80732059@qq.com; Luo, Xuefeng, E-mail: luobo-913@126.com; Ye, Linchao, E-mail: linchao.ye@siemens.com

    2015-06-15

    PurposeThis study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS).Methods3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate themore » angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients.ResultsFailure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures.ConclusionsAdjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.« less

  5. Structural elucidation of antihemorrhage drug molecule Diethylammonium 2,5-dihydroxybenzene sulfonate - an insilico approach

    NASA Astrophysics Data System (ADS)

    Kumar, S. Anil; Bhaskar, BL

    2018-02-01

    Ab-initio computational study of antihemorrhage drug molecule diethylammonium 2,5-dihydroxybenzene sulfonate, popularly known as ethamsylate, has been attempted using Gaussian 09. The optimized molecular geometry has been envisaged using density functional theory method at B3LYP/6-311 basis set. Different geometrical parameters like bond lengths and bond angles were computed and compared against the experimental results available in literature. Fourier transform infrared scanning of the title molecule was performed and vibrational frequencies were also computed using Gaussian software. The presence of O-H---O hydrogen bonds between C6H5O5S- anions and N-H---O hydrogen bonds between anion and cation is evident in the computational studies also. In general, satisfactory agreement of concordance has been observed between computational and experimental results.

  6. Design, Fabrication, and Testing of a Hopper Spacecraft Simulator

    NASA Astrophysics Data System (ADS)

    Mucasey, Evan Phillip Krell

    A robust test bed is needed to facilitate future development of guidance, navigation, and control software for future vehicles capable of vertical takeoff and landings. Specifically, this work aims to develop both a hardware and software simulator that can be used for future flight software development for extra-planetary vehicles. To achieve the program requirements of a high thrust to weight ratio with large payload capability, the vehicle is designed to have a novel combination of electric motors and a micro jet engine is used to act as the propulsion elements. The spacecraft simulator underwent several iterations of hardware development using different materials and fabrication methods. The final design used a combination of carbon fiber and fiberglass that was cured under vacuum to serve as the frame of the vehicle which provided a strong, lightweight platform for all flight components and future payloads. The vehicle also uses an open source software development platform, Arduino, to serve as the initial flight computer and has onboard accelerometers, gyroscopes, and magnetometers to sense the vehicles attitude. To prevent instability due to noise, a polynomial kalman filter was designed and this fed the sensed angles and rates into a robust attitude controller which autonomously control the vehicle' s yaw, pitch, and roll angles. In addition to the hardware development of the vehicle itself, both a software simulation and a real time data acquisition interface was written in MATLAB/SIMULINK so that real flight data could be taken and then correlated to the simulation to prove the accuracy of the analytical model. In result, the full scale vehicle was designed and own outside of the lab environment and data showed that the software model accurately predicted the flight dynamics of the vehicle.

  7. Image analysis software as a strategy to improve the radiographic determination of fracture healing.

    PubMed

    Duryea, Jeffrey; Evans, Christopher; Glatt, Vaida

    2018-05-28

    To develop and validate an unbiased, accurate, convenient and inexpensive means of determining when an osseous defect has healed and recovered sufficient strength to allow weight-bearing. A novel image processing software algorithm was created to analyze the radiographic images and produce a metric designed to reflect the bone strength. We used a rat femoral segmental defect model that provides a range of healing responses from complete union to non-union. Femora were examined by X-ray, micro-computed tomography (µCT) and mechanical testing. Accurate simulated radiographic images at different incident X-ray beam angles were produced from the µCT data files. The software-generated metric (SC) showed high levels of correlation with both the mechanical strength (τMech) and the polar moment of inertia (pMOI), with the mechanical testing data having the highest association. The optimization analysis yielded optimal oblique angles θB of 125° for τMech and 50° for pMOI. The Pearson's R values for the optimized model were 0.71 and 0.64 for τMech and pMOI, respectively. Further validation using true radiographs also demonstrated that the metric was accurate, and that the simulations were realistic. The preliminary findings suggest a very promising methodology to assess bone fracture healing using conventional radiography. With radiographs acquired at appropriate incident angles, it proved possible to calculate accurately the degree of healing and the mechanical strength of the bone. Further research is necessary to refine this approach and determine whether it translates to the human clinical setting.

  8. Common Ada (tradename) Missile Package (CAMP) Project. Missile Software Parts. Volume 8. Detail Design Document

    DTIC Science & Technology

    1988-03-01

    PACKAGE BODY ) TLCSC P661 (CATALOG #P106-0) This package contains the CAMP parts required to do the vaypoint steering portion of navigation. The...3.3.4.1.6 PROCESSING The following describes the processing performed by this part: package body WaypointSteering is package body ...Steering_Vector_Operations is separate; package body Steering_Vector_Operations_with_Arcsin is separate; procedure Compute Turn_Angle_and Direction (UnitNormal C

  9. Software Impact of Selected En Route ATC Computer Replacement Strategies.

    DTIC Science & Technology

    1979-12-01

    Compare 188 SDG Duplicate Flight Plan Search 558 SDU Amendment Output Initiator 3,094 SHA Heading Angle Correction 22 STB Chained -Table Management 278...communications) 1would be required in both systems. However the uses of MK in the two systems to supply information to the two copies of SBB would be...this, all current use of Commniand Chaining -11- and Program Controlled Interrupts will have to be deleted from the existing 9020 programs. For the

  10. Ship Air Wake Detection Using a Small Fixed Wing Unmanned Aerial Vehicle

    NASA Astrophysics Data System (ADS)

    Phelps, David M.

    A ship's air wake is dynamically detected using an airborne inertial measurement unit (IMU) and global positioning system (GPS) attached to a fixed wing unmanned aerial system. A fixed wing unmanned aerial system (UAS) was flown through the air wake created by an underway 108 ft (32.9m) long research vessel in pre designated flight paths. The instrumented aircraft was used to validate computational fluid dynamic (CFD) simulations of naval ship air wakes. Computer models of the research ship and the fixed wing UAS were generated and gridded using NASA's TetrUSS software. Simulations were run using Kestrel, a Department of Defense CFD software to validate the physical experimental data collection method. Air wake simulations were run at various relative wind angles and speeds. The fixed wing UAS was subjected to extensive wind tunnel testing to generate a table of aerodynamic coefficients as a function of control surface deflections, angle of attack and sideslip. The wind tunnel experimental data was compared against similarly structured CFD experiments to validate the grid and model of fixed wing UAS. Finally, a CFD simulation of the fixed wing UAV flying through the generated wake was completed. Forces on the instrumented aircraft were calculated from the data collected by the IMU. Comparison of experimental and simulation data showed that the fixed wing UAS could detect interactions with the ship air wake.

  11. The polyGeVero® software for fast and easy computation of 3D radiotherapy dosimetry data

    NASA Astrophysics Data System (ADS)

    Kozicki, Marek; Maras, Piotr

    2015-01-01

    The polyGeVero® software package was elaborated for calculations of 3D dosimetry data such as the polymer gel dosimetry. It comprises four workspaces designed for: i) calculating calibrations, ii) storing calibrations in a database, iii) calculating dose distribution 3D cubes, iv) comparing two datasets e.g. a measured one with a 3D dosimetry with a calculated one with the aid of a treatment planning system. To accomplish calculations the software was equipped with a number of tools such as the brachytherapy isotopes database, brachytherapy dose versus distance calculation based on the line approximation approach, automatic spatial alignment of two 3D dose cubes for comparison purposes, 3D gamma index, 3D gamma angle, 3D dose difference, Pearson's coefficient, histograms calculations, isodoses superimposition for two datasets, and profiles calculations in any desired direction. This communication is to briefly present the main functions of the software and report on the speed of calculations performed by polyGeVero®.

  12. Simulating Effects of High Angle of Attack on Turbofan Engine Performance

    NASA Technical Reports Server (NTRS)

    Liu, Yuan; Claus, Russell W.; Litt, Jonathan S.; Guo, Ten-Huei

    2013-01-01

    A method of investigating the effects of high angle of attack (AOA) flight on turbofan engine performance is presented. The methodology involves combining a suite of diverse simulation tools. Three-dimensional, steady-state computational fluid dynamics (CFD) software is used to model the change in performance of a commercial aircraft-type inlet and fan geometry due to various levels of AOA. Parallel compressor theory is then applied to assimilate the CFD data with a zero-dimensional, nonlinear, dynamic turbofan engine model. The combined model shows that high AOA operation degrades fan performance and, thus, negatively impacts compressor stability margins and engine thrust. In addition, the engine response to high AOA conditions is shown to be highly dependent upon the type of control system employed.

  13. Automatic AVHRR image navigation software

    NASA Technical Reports Server (NTRS)

    Baldwin, Dan; Emery, William

    1992-01-01

    This is the final report describing the work done on the project entitled Automatic AVHRR Image Navigation Software funded through NASA-Washington, award NAGW-3224, Account 153-7529. At the onset of this project, we had developed image navigation software capable of producing geo-registered images from AVHRR data. The registrations were highly accurate but required a priori knowledge of the spacecraft's axes alignment deviations, commonly known as attitude. The three angles needed to describe the attitude are called roll, pitch, and yaw, and are the components of the deviations in the along scan, along track and about center directions. The inclusion of the attitude corrections in the navigation software results in highly accurate georegistrations, however, the computation of the angles is very tedious and involves human interpretation for several steps. The technique also requires easily identifiable ground features which may not be available due to cloud cover or for ocean data. The current project was motivated by the need for a navigation system which was automatic and did not require human intervention or ground control points. The first step in creating such a system must be the ability to parameterize the spacecraft's attitude. The immediate goal of this project was to study the attitude fluctuations and determine if they displayed any systematic behavior which could be modeled or parameterized. We chose a period in 1991-1992 to study the attitude of the NOAA 11 spacecraft using data from the Tiros receiving station at the Colorado Center for Astrodynamic Research (CCAR) at the University of Colorado.

  14. Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test.

    PubMed

    Muller, Bart; Hofbauer, Marcus; Rahnemai-Azar, Amir Ata; Wolf, Megan; Araki, Daisuke; Hoshino, Yuichi; Araujo, Paulo; Debski, Richard E; Irrgang, James J; Fu, Freddie H; Musahl, Volker

    2016-01-01

    The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 45°. Average percent error during anterior translation of the lateral knee compartment of 6mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.

  15. Assessing Uncertainties in Boundary Layer Transition Predictions for HIFiRE-1 at Non-zero Angles of Attack

    NASA Technical Reports Server (NTRS)

    Marek, Lindsay C.

    2011-01-01

    Boundary layer stability was analyzed for the HIFiRE-1 flight vehicle geometry for ground tests conducted at the CUBRC LENS I hypersonic shock test facility and the Langley Research Center (LaRC) 20- inch Mach 6 Tunnel. Boundary layer stability results were compared to transition onset location obtained from discrete heat transfer measurements from thin film gauges during the CUBRC test and spatially continuous heat transfer measurements from thermal phosphor paint data during the LaRC test. The focus of this analysis was on conditions at non-zero angles of attack as stability analysis has already been performed at zero degrees angle of attack. Also, the transition onset data obtained during flight testing was at nonzero angles of attack, so this analysis could be expanded in the future to include the results of the flight test data. Stability analysis was performed using the 2D parabolized stability software suite STABL (Stability and Transition Analysis for Hypersonic Boundary Layers) developed at the University of Minnesota and the mean flow solutions were computed using the DPLR finite volume Navier-Stokes computational fluid dynamics (CFD) solver. A center line slice of the 3D mean flow solution was used for the stability analysis to incorporate the angle of attack effects while still taking advantage of the 2D STABL software suite. The N-factors at transition onset and the value of Re(sub theta)/M(sub e), commonly used to predict boundary layer transition onset, were compared for all conditions analyzed. Ground test data was analyzed at Mach 7.2 and Mach 6.0 and angles of attack of 1deg, 3deg and 5deg. At these conditions, the flow was found to be second mode dominant for the HIFiRE-1 slender cone geometry. On the leeward side of the vehicle, a strong trend of transition onset location with angle of attack was observed as the boundary layer on the leeward side of the vehicle developed inflection points at streamwise positions on the vehicle that correlated to angle of attack. Inflection points are a strong instability mechanism that lead to rapid breakdown and transition to turbulence. The transition onset location on the windward side of the vehicle displayed no trend with angle of attack or freestream Reynolds number and transition was observed farther down the vehicle than observed on the leeward side of the vehicle. In analysis of both windward and leeward sides of the vehicle, use of the N factor methodology to develop trends to predict boundary layer transition onset showed improvements over the Re(sub theta)/M(sub e) empirical correlation methodology. Stronger correlations and less scatter in the data were observed when using the N factor method for these cases.

  16. Using Microsoft PowerPoint as an Astronomical Image Analysis Tool

    NASA Astrophysics Data System (ADS)

    Beck-Winchatz, Bernhard

    2006-12-01

    Engaging students in the analysis of authentic scientific data is an effective way to teach them about the scientific process and to develop their problem solving, teamwork and communication skills. In astronomy several image processing and analysis software tools have been developed for use in school environments. However, the practical implementation in the classroom is often difficult because the teachers may not have the comfort level with computers necessary to install and use these tools, they may not have adequate computer privileges and/or support, and they may not have the time to learn how to use specialized astronomy software. To address this problem, we have developed a set of activities in which students analyze astronomical images using basic tools provided in PowerPoint. These include measuring sizes, distances, and angles, and blinking images. In contrast to specialized software, PowerPoint is broadly available on school computers. Many teachers are already familiar with PowerPoint, and the skills developed while learning how to analyze astronomical images are highly transferable. We will discuss several practical examples of measurements, including the following: -Variations in the distances to the sun and moon from their angular sizes -Magnetic declination from images of shadows -Diameter of the moon from lunar eclipse images -Sizes of lunar craters -Orbital radii of the Jovian moons and mass of Jupiter -Supernova and comet searches -Expansion rate of the universe from images of distant galaxies

  17. Recent advances in the UltraScan SOlution MOdeller (US-SOMO) hydrodynamic and small-angle scattering data analysis and simulation suite.

    PubMed

    Brookes, Emre; Rocco, Mattia

    2018-03-28

    The UltraScan SOlution MOdeller (US-SOMO) is a comprehensive, public domain, open-source suite of computer programs centred on hydrodynamic modelling and small-angle scattering (SAS) data analysis and simulation. We describe here the advances that have been implemented since its last official release (#3087, 2017), which are available from release #3141 for Windows, Linux and Mac operating systems. A major effort has been the transition from the legacy Qt3 cross platform software development and user interface library to the modern Qt5 release. Apart from improved graphical support, this has allowed the direct implementation of the newest, almost two-orders of magnitude faster version of the ZENO hydrodynamic computation algorithm for all operating systems. Coupled with the SoMo-generated bead models with overlaps, ZENO provides the most accurate translational friction computations from atomic-level structures available (Rocco and Byron Eur Biophys J 44:417-431, 2015a), with computational times comparable with or faster than those of other methods. In addition, it has allowed us to introduce the direct representation of each atom in a structure as a (hydrated) bead, opening interesting new modelling possibilities. In the small-angle scattering (SAS) part of the suite, an indirect Fourier transform Bayesian algorithm has been implemented for the computation of the pairwise distance distribution function from SAS data. Finally, the SAS HPLC module, recently upgraded with improved baseline correction and Gaussian decomposition of not baseline-resolved peaks and with advanced statistical evaluation tools (Brookes et al. J Appl Cryst 49:1827-1841, 2016), now allows automatic top-peak frame selection and averaging.

  18. 48 CFR 227.7203-15 - Subcontractor rights in computer software or computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... computer software or computer software documentation. 227.7203-15 Section 227.7203-15 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-15 Subcontractor rights in computer software or computer software documentation. (a...

  19. 48 CFR 227.7203-15 - Subcontractor rights in computer software or computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... computer software or computer software documentation. 227.7203-15 Section 227.7203-15 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-15 Subcontractor rights in computer software or computer software documentation. (a...

  20. 48 CFR 227.7203-15 - Subcontractor rights in computer software or computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computer software or computer software documentation. 227.7203-15 Section 227.7203-15 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-15 Subcontractor rights in computer software or computer software documentation. (a...

  1. 48 CFR 227.7203-15 - Subcontractor rights in computer software or computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... computer software or computer software documentation. 227.7203-15 Section 227.7203-15 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-15 Subcontractor rights in computer software or computer software documentation. (a...

  2. 48 CFR 227.7203-15 - Subcontractor rights in computer software or computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... computer software or computer software documentation. 227.7203-15 Section 227.7203-15 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-15 Subcontractor rights in computer software or computer software documentation. (a...

  3. 48 CFR 227.7202 - Commercial computer software and commercial computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software and commercial computer software documentation. 227.7202 Section 227.7202 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202 Commercial computer software and commercial computer software documentation. ...

  4. 48 CFR 227.7203 - Noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software and noncommercial computer software documentation. 227.7203 Section 227.7203 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203 Noncommercial computer software and noncommercial computer software documentation. ...

  5. 48 CFR 227.7203 - Noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software and noncommercial computer software documentation. 227.7203 Section 227.7203 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203 Noncommercial computer software and noncommercial computer software documentation. ...

  6. 48 CFR 227.7203 - Noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software and noncommercial computer software documentation. 227.7203 Section 227.7203 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203 Noncommercial computer software and noncommercial computer software documentation. ...

  7. 48 CFR 227.7202 - Commercial computer software and commercial computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software and commercial computer software documentation. 227.7202 Section 227.7202 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202 Commercial computer software and commercial computer software documentation. ...

  8. 48 CFR 227.7203 - Noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software and noncommercial computer software documentation. 227.7203 Section 227.7203 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203 Noncommercial computer software and noncommercial computer software documentation. ...

  9. 48 CFR 227.7202 - Commercial computer software and commercial computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software and commercial computer software documentation. 227.7202 Section 227.7202 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202 Commercial computer software and commercial computer software documentation. ...

  10. 48 CFR 227.7202 - Commercial computer software and commercial computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software and commercial computer software documentation. 227.7202 Section 227.7202 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202 Commercial computer software and commercial computer software documentation. ...

  11. 48 CFR 227.7202 - Commercial computer software and commercial computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software and commercial computer software documentation. 227.7202 Section 227.7202 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202 Commercial computer software and commercial computer software documentation. ...

  12. 48 CFR 227.7203 - Noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software and noncommercial computer software documentation. 227.7203 Section 227.7203 Federal Acquisition... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203 Noncommercial computer software and noncommercial computer software documentation. ...

  13. Monitoring system of multiple fire fighting based on computer vision

    NASA Astrophysics Data System (ADS)

    Li, Jinlong; Wang, Li; Gao, Xiaorong; Wang, Zeyong; Zhao, Quanke

    2010-10-01

    With the high demand of fire control in spacious buildings, computer vision is playing a more and more important role. This paper presents a new monitoring system of multiple fire fighting based on computer vision and color detection. This system can adjust to the fire position and then extinguish the fire by itself. In this paper, the system structure, working principle, fire orientation, hydrant's angle adjusting and system calibration are described in detail; also the design of relevant hardware and software is introduced. At the same time, the principle and process of color detection and image processing are given as well. The system runs well in the test, and it has high reliability, low cost, and easy nodeexpanding, which has a bright prospect of application and popularization.

  14. 48 CFR 227.7202-3 - Rights in commercial computer software or commercial computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computer software or commercial computer software documentation. 227.7202-3 Section 227.7202-3 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-3 Rights in commercial computer software or commercial computer software documentation...

  15. 48 CFR 227.7202-3 - Rights in commercial computer software or commercial computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... computer software or commercial computer software documentation. 227.7202-3 Section 227.7202-3 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-3 Rights in commercial computer software or commercial computer software documentation...

  16. 48 CFR 227.7203-2 - Acquisition of noncommercial computer software and computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... noncommercial computer software and computer software documentation. 227.7203-2 Section 227.7203-2 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-2 Acquisition of noncommercial computer software and computer software documentation. (a...

  17. 48 CFR 227.7203-2 - Acquisition of noncommercial computer software and computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... noncommercial computer software and computer software documentation. 227.7203-2 Section 227.7203-2 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-2 Acquisition of noncommercial computer software and computer software documentation. (a...

  18. 48 CFR 227.7203-2 - Acquisition of noncommercial computer software and computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... noncommercial computer software and computer software documentation. 227.7203-2 Section 227.7203-2 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-2 Acquisition of noncommercial computer software and computer software documentation. (a...

  19. 48 CFR 227.7203-10 - Contractor identification and marking of computer software or computer software documentation to...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and marking of computer software or computer software documentation to be furnished with restrictive... Rights in Computer Software and Computer Software Documentation 227.7203-10 Contractor identification and marking of computer software or computer software documentation to be furnished with restrictive markings...

  20. 48 CFR 227.7203-2 - Acquisition of noncommercial computer software and computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... noncommercial computer software and computer software documentation. 227.7203-2 Section 227.7203-2 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-2 Acquisition of noncommercial computer software and computer software documentation. (a...

  1. 48 CFR 227.7202-3 - Rights in commercial computer software or commercial computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... computer software or commercial computer software documentation. 227.7202-3 Section 227.7202-3 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-3 Rights in commercial computer software or commercial computer software documentation...

  2. 48 CFR 227.7203-10 - Contractor identification and marking of computer software or computer software documentation to...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and marking of computer software or computer software documentation to be furnished with restrictive... Rights in Computer Software and Computer Software Documentation 227.7203-10 Contractor identification and marking of computer software or computer software documentation to be furnished with restrictive markings...

  3. 48 CFR 227.7202-3 - Rights in commercial computer software or commercial computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... computer software or commercial computer software documentation. 227.7202-3 Section 227.7202-3 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-3 Rights in commercial computer software or commercial computer software documentation...

  4. 48 CFR 227.7203-10 - Contractor identification and marking of computer software or computer software documentation to...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and marking of computer software or computer software documentation to be furnished with restrictive... Rights in Computer Software and Computer Software Documentation 227.7203-10 Contractor identification and marking of computer software or computer software documentation to be furnished with restrictive markings...

  5. 48 CFR 227.7202-3 - Rights in commercial computer software or commercial computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... computer software or commercial computer software documentation. 227.7202-3 Section 227.7202-3 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-3 Rights in commercial computer software or commercial computer software documentation...

  6. 48 CFR 227.7203-10 - Contractor identification and marking of computer software or computer software documentation to...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and marking of computer software or computer software documentation to be furnished with restrictive... Rights in Computer Software and Computer Software Documentation 227.7203-10 Contractor identification and marking of computer software or computer software documentation to be furnished with restrictive markings...

  7. 48 CFR 227.7203-10 - Contractor identification and marking of computer software or computer software documentation to...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and marking of computer software or computer software documentation to be furnished with restrictive... Rights in Computer Software and Computer Software Documentation 227.7203-10 Contractor identification and marking of computer software or computer software documentation to be furnished with restrictive markings...

  8. 48 CFR 227.7203-2 - Acquisition of noncommercial computer software and computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... noncommercial computer software and computer software documentation. 227.7203-2 Section 227.7203-2 Federal... CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-2 Acquisition of noncommercial computer software and computer software documentation. (a...

  9. SU-G-BRC-04: Collimator Angle Optimization in Volumetric Modulated Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, A; Johnson, C; Bartlett, G

    2016-06-15

    Purpose: Volumetric modulated arc therapy (VMAT) has revolutionized radiation treatment by decreasing treatment time and monitor units, thus reducing scattered and whole body radiation dose. As the collimator angle changes the apparent leaf gap becomes larger which can impact plan quality, organ at risk (OAR) sparing as well as IMRT QA passing rate which is investigated. Methods: Two sites (prostate and head and neck) that have maximum utilization of VMAT were investigated. Two previously treated VMAT patients were chosen. For each patient 10 plans were created by maintaining constant optimization constraints while varying collimator angles from 0-90 deg at anmore » interval of 10 degrees for the first arc and the appropriate complimentary angle for the second arc. Plans were created with AAA algorithm using 6 MV beam on a Varian IX machine with Millennium 120 MLC. The dose-volume histogram (DVH) for each plan was exported and dosimetric parameters (D98, D95, D50, D2) as well homogeneity index (HI) and conformity index (CI) were computed. Each plan was validated for QA using ArcCheck with gamma index passing criteria of 2%/2 mm and 3%/3 mm. Additionally, normal tissue complication probability (NTCP) for each OAR was computed using Uzan-Nahum software. Results: The CI values for both sites had no impact as target volume coverage in every collimator angle were the same since it was optimized for adequate coverage. The HI which is representative of DVH gradient or dose uniformity in PTV showed a clear trend in both sites. The NTCP for OAR (brain and cochlea) in H&N plan and (bladder and rectum) in prostate plan showed a distinct superiority for collimator angles between 15-30 deg. The gamma passing rates were not correlated with angle. Conclusion: Based on CI, HI, NTCP and gamma passing index, it can be concluded that collimator angles should be maintained within 15–30 deg.« less

  10. 48 CFR 227.7203-16 - Providing computer software or computer software documentation to foreign governments, foreign...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software or computer software documentation to foreign governments, foreign contractors, or international... Rights in Computer Software and Computer Software Documentation 227.7203-16 Providing computer software or computer software documentation to foreign governments, foreign contractors, or international...

  11. 48 CFR 227.7203-16 - Providing computer software or computer software documentation to foreign governments, foreign...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software or computer software documentation to foreign governments, foreign contractors, or international... Rights in Computer Software and Computer Software Documentation 227.7203-16 Providing computer software or computer software documentation to foreign governments, foreign contractors, or international...

  12. 48 CFR 227.7203-16 - Providing computer software or computer software documentation to foreign governments, foreign...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software or computer software documentation to foreign governments, foreign contractors, or international... Rights in Computer Software and Computer Software Documentation 227.7203-16 Providing computer software or computer software documentation to foreign governments, foreign contractors, or international...

  13. 48 CFR 227.7203-16 - Providing computer software or computer software documentation to foreign governments, foreign...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software or computer software documentation to foreign governments, foreign contractors, or international... Rights in Computer Software and Computer Software Documentation 227.7203-16 Providing computer software or computer software documentation to foreign governments, foreign contractors, or international...

  14. 48 CFR 227.7203-16 - Providing computer software or computer software documentation to foreign governments, foreign...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software or computer software documentation to foreign governments, foreign contractors, or international... Rights in Computer Software and Computer Software Documentation 227.7203-16 Providing computer software or computer software documentation to foreign governments, foreign contractors, or international...

  15. Analysis of forward scattering of an acoustical zeroth-order Bessel beam from rigid complicated (aspherical) structures

    NASA Astrophysics Data System (ADS)

    Li, Wei; Chai, Yingbin; Gong, Zhixiong; Marston, Philip L.

    2017-10-01

    The forward scattering from rigid spheroids and endcapped cylinders with finite length (even with a large aspect ratio) immersed in a non-viscous fluid under the illumination of an idealized zeroth-order acoustical Bessel beam (ABB) with arbitrary angles of incidence is calculated and analyzed in the implementation of the T-matrix method (TTM). Based on the present method, the incident coefficients of expansion for the incident ABB are derived and simplifying methods are proposed for the numerical accuracy and computational efficiency according to the geometrical symmetries. A home-made MATLAB software package is constructed accordingly, and then verified and validated for the ABB scattering from rigid aspherical obstacles. Several numerical examples are computed for the forward scattering from both rigid spheroids and finite cylinder, with particular emphasis on the aspect ratios, the half-cone angles of ABBs, the incident angles and the dimensionless frequencies. The rectangular patterns of target strength in the (β, θs) domain (where β is the half-cone angle of the ABB and θs is the scattered polar angle) and local/total forward scattering versus dimensionless frequency are exhibited, which could provide new insights into the physical mechanisms of Bessel beam scattering by rigid spheroids and finite cylinders. The ray diagrams in geometrical models for the scattering in the forward half-space and the optical cross-section theorem help to interpret the scattering mechanisms of ABBs. This research work may provide an alternative for the partial wave series solution under certain circumstances interacting with ABBs for complicated obstacles and benefit some related works in optics and electromagnetics.

  16. 48 CFR 227.7203-3 - Early identification of computer software or computer software documentation to be furnished to...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computer software or computer software documentation to be furnished to the Government with restrictions on..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-3 Early identification of computer software or computer software documentation to be furnished to the Government with...

  17. 48 CFR 227.7203-3 - Early identification of computer software or computer software documentation to be furnished to...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... computer software or computer software documentation to be furnished to the Government with restrictions on..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-3 Early identification of computer software or computer software documentation to be furnished to the Government with...

  18. 48 CFR 227.7203-3 - Early identification of computer software or computer software documentation to be furnished to...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... computer software or computer software documentation to be furnished to the Government with restrictions on..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-3 Early identification of computer software or computer software documentation to be furnished to the Government with...

  19. 48 CFR 227.7203-3 - Early identification of computer software or computer software documentation to be furnished to...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... computer software or computer software documentation to be furnished to the Government with restrictions on..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-3 Early identification of computer software or computer software documentation to be furnished to the Government with...

  20. 48 CFR 227.7203-3 - Early identification of computer software or computer software documentation to be furnished to...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... computer software or computer software documentation to be furnished to the Government with restrictions on..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-3 Early identification of computer software or computer software documentation to be furnished to the Government with...

  1. [Inferring landmark displacements from changes in cephalometric angles].

    PubMed

    Xu, T; Baumrind, S

    2001-07-01

    To investigate the appropriateness of using changes in angular measurements to reflect the actually profile changes. The sample consists of 48 growing malocclusion patients, contained 24 Class I and 24 Class II subjects, treated by an experienced orthodontist using Edgewise technique. Landmark and superimpositional data were extracted from the previously prepared numerical database. Three pairs of angular and linear measures were computed by the Craniofacial Software Package. Although the associations between all three angular measures and their corresponding linear measures are statistically significant at the 0.001 level, the disagreement between these three pairs of measures are 10.4%, 22.9% and 37.5% respectively in this sample. The direction of displacement of anterior facial landmarks during growth and treatment cannot reliably be inferred merely from changes in cephalometric Angles.

  2. Evaluation of SLAR and thematic mapper MSS data for forest cover mapping using computer-aided analysis techniques

    NASA Technical Reports Server (NTRS)

    Hoffer, R. M. (Principal Investigator)

    1980-01-01

    The column normalizing technique was used to adjust the data for variations in the amplitude of the signal due to look angle effects with respect to solar zenith angle along the scan lines (i.e., across columns). Evaluation of the data set containing the geometric and radiometric adjustments, indicates that the data set should be satisfactory for further processing and analysis. Software was developed for degrading the spatial resolution of the aircraft data to produce a total of four data sets for further analysis. The quality of LANDSAT 2 CCT data for the test site is good for channels four, five, and six. Channel seven was not present on the tape. The data received were reformatted and analysis of the test site area was initiated.

  3. 48 CFR 227.7203-14 - Conformity, acceptance, and warranty of computer software and computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., and warranty of computer software and computer software documentation. 227.7203-14 Section 227.7203-14... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-14 Conformity, acceptance, and warranty of computer software and computer...

  4. 48 CFR 227.7203-14 - Conformity, acceptance, and warranty of computer software and computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and warranty of computer software and computer software documentation. 227.7203-14 Section 227.7203-14... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-14 Conformity, acceptance, and warranty of computer software and computer...

  5. 48 CFR 227.7203-14 - Conformity, acceptance, and warranty of computer software and computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., and warranty of computer software and computer software documentation. 227.7203-14 Section 227.7203-14... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-14 Conformity, acceptance, and warranty of computer software and computer...

  6. 48 CFR 227.7203-14 - Conformity, acceptance, and warranty of computer software and computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., and warranty of computer software and computer software documentation. 227.7203-14 Section 227.7203-14... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-14 Conformity, acceptance, and warranty of computer software and computer...

  7. 48 CFR 227.7203-14 - Conformity, acceptance, and warranty of computer software and computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., and warranty of computer software and computer software documentation. 227.7203-14 Section 227.7203-14... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-14 Conformity, acceptance, and warranty of computer software and computer...

  8. Construction of a three-dimensional interactive model of the skull base and cranial nerves.

    PubMed

    Kakizawa, Yukinari; Hongo, Kazuhiro; Rhoton, Albert L

    2007-05-01

    The goal was to develop an interactive three-dimensional (3-D) computerized anatomic model of the skull base for teaching microneurosurgical anatomy and for operative planning. The 3-D model was constructed using commercially available software (Maya 6.0 Unlimited; Alias Systems Corp., Delaware, MD), a personal computer, four cranial specimens, and six dry bones. Photographs from at least two angles of the superior and lateral views were imported to the 3-D software. Many photographs were needed to produce the model in anatomically complex areas. Careful dissection was needed to expose important structures in the two views. Landmarks, including foramen, bone, and dura mater, were used as reference points. The 3-D model of the skull base and related structures was constructed using more than 300,000 remodeled polygons. The model can be viewed from any angle. It can be rotated 360 degrees in any plane using any structure as the focal point of rotation. The model can be reduced or enlarged using the zoom function. Variable transparencies could be assigned to any structures so that the structures at any level can be seen. Anatomic labels can be attached to the structures in the 3-D model for educational purposes. This computer-generated 3-D model can be observed and studied repeatedly without the time limitations and stresses imposed by surgery. This model may offer the potential to create interactive surgical exercises useful in evaluating multiple surgical routes to specific target areas in the skull base.

  9. 48 CFR 227.7203-8 - Deferred delivery and deferred ordering of computer software and computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... deferred ordering of computer software and computer software documentation. 227.7203-8 Section 227.7203-8... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-8 Deferred delivery and deferred ordering of computer software and computer...

  10. 48 CFR 227.7203-8 - Deferred delivery and deferred ordering of computer software and computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... deferred ordering of computer software and computer software documentation. 227.7203-8 Section 227.7203-8... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-8 Deferred delivery and deferred ordering of computer software and computer...

  11. 48 CFR 227.7203-8 - Deferred delivery and deferred ordering of computer software and computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... deferred ordering of computer software and computer software documentation. 227.7203-8 Section 227.7203-8... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-8 Deferred delivery and deferred ordering of computer software and computer...

  12. 48 CFR 227.7203-8 - Deferred delivery and deferred ordering of computer software and computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... deferred ordering of computer software and computer software documentation. 227.7203-8 Section 227.7203-8... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-8 Deferred delivery and deferred ordering of computer software and computer...

  13. 48 CFR 227.7203-8 - Deferred delivery and deferred ordering of computer software and computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... deferred ordering of computer software and computer software documentation. 227.7203-8 Section 227.7203-8... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-8 Deferred delivery and deferred ordering of computer software and computer...

  14. 48 CFR 252.227-7014 - Rights in noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... computer software and noncommercial computer software documentation. 252.227-7014 Section 252.227-7014... Rights in noncommercial computer software and noncommercial computer software documentation. As prescribed in 227.7203-6(a)(1), use the following clause. Rights in Noncommercial Computer Software and...

  15. 48 CFR 252.227-7014 - Rights in noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... computer software and noncommercial computer software documentation. 252.227-7014 Section 252.227-7014... Rights in noncommercial computer software and noncommercial computer software documentation. As prescribed in 227.7203-6(a)(1), use the following clause. Rights in Noncommercial Computer Software and...

  16. 48 CFR 252.227-7014 - Rights in noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... computer software and noncommercial computer software documentation. 252.227-7014 Section 252.227-7014... Rights in noncommercial computer software and noncommercial computer software documentation. As prescribed in 227.7203-6(a)(1), use the following clause. Rights in Noncommercial Computer Software and...

  17. 48 CFR 252.227-7014 - Rights in noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... computer software and noncommercial computer software documentation. 252.227-7014 Section 252.227-7014... Rights in noncommercial computer software and noncommercial computer software documentation. As prescribed in 227.7203-6(a)(1), use the following clause. Rights in Noncommercial Computer Software and...

  18. 48 CFR 252.227-7014 - Rights in noncommercial computer software and noncommercial computer software documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computer software and noncommercial computer software documentation. 252.227-7014 Section 252.227-7014... Rights in noncommercial computer software and noncommercial computer software documentation. As prescribed in 227.7203-6(a)(1), use the following clause. Rights in Noncommercial Computer Software and...

  19. 3D DEM analyses of the 1963 Vajont rock slide

    NASA Astrophysics Data System (ADS)

    Boon, Chia Weng; Houlsby, Guy; Utili, Stefano

    2013-04-01

    The 1963 Vajont rock slide has been modelled using the distinct element method (DEM). The open-source DEM code, YADE (Kozicki & Donzé, 2008), was used together with the contact detection algorithm proposed by Boon et al. (2012). The critical sliding friction angle at the slide surface was sought using a strength reduction approach. A shear-softening contact model was used to model the shear resistance of the clayey layer at the slide surface. The results suggest that the critical sliding friction angle can be conservative if stability analyses are calculated based on the peak friction angles. The water table was assumed to be horizontal and the pore pressure at the clay layer was assumed to be hydrostatic. The influence of reservoir filling was marginal, increasing the sliding friction angle by only 1.6˚. The results of the DEM calculations were found to be sensitive to the orientations of the bedding planes and cross-joints. Finally, the failure mechanism was investigated and arching was found to be present at the bend of the chair-shaped slope. References Boon C.W., Houlsby G.T., Utili S. (2012). A new algorithm for contact detection between convex polygonal and polyhedral particles in the discrete element method. Computers and Geotechnics, vol 44, 73-82, doi.org/10.1016/j.compgeo.2012.03.012. Kozicki, J., & Donzé, F. V. (2008). A new open-source software developed for numerical simulations using discrete modeling methods. Computer Methods in Applied Mechanics and Engineering, 197(49-50), 4429-4443.

  20. Pandora Operation and Analysis Software

    NASA Technical Reports Server (NTRS)

    Herman, Jay; Cede, Alexander; Abuhassan, Nader

    2012-01-01

    Pandora Operation and Analysis Software controls the Pandora Sun- and sky-pointing optical head and built-in filter wheels (neutral density, UV bandpass, polarization filters, and opaque). The software also controls the attached spectrometer exposure time and thermoelectric cooler to maintain the spectrometer temperature to within 1 C. All functions are available through a GUI so as to be easily accessible by the user. The data are automatically stored on a miniature computer (netbook) for automatic download to a designated server at user defined intervals (once per day, once per week, etc.), or to a USB external device. An additional software component reduces the raw data (spectrometer counts) to preliminary scientific products for quick-view purposes. The Pandora systems are built from off-the-shelf commercial parts and from mechanical parts machined using electronic machine shop drawings. The Pandora spectrometer system is designed to look at the Sun (tracking to within 0.1 ), or to look at the sky at any zenith or azimuth angle, to gather information about the amount of trace gases or aerosols that are present.

  1. Computer-based simulation of the Bielschowsky head-tilt test using the SEE++ software system.

    PubMed

    Kaltofen, Thomas; Buchberger, Michael; Priglinger, Siegfried

    2008-01-01

    Latest measurements of the vestibulo-ocular reflex (VOR) allowed the integration of the simulation of the Bielschowsky head-tilt test (BHTT) into the SEE++ software system. SEE++ realizes a biomechanical model of the human eye in order to simulate eye motility disorders and strabismus surgeries. With the addition of the BHTT it can now also be used for differential-diagnostic simulations of complex disorders (e.g., superior oblique palsies). In order to simulate the BHTT in SEE++, the user can freely choose the desired head-tilt angle from -45 degrees to +45 degrees. The chosen angle is shown in the 3D view with a human body model and is also used in the calculation of the Hess-Lancaster test. The integration of the BHTT offers an additional improvement of the possibilities for simulating eye motility disorders. Moreover, SEE++ allows the creation of a video of the "virtual patient" while tilting the head from one side to the other, which shows dynamic changes in the simulated Hess-diagrams. Comparisons of simulation results with patient-measured data showed a good correlation between the simulated and the measured data. Further comparisons with patient data are planned.

  2. Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study

    PubMed Central

    Mao, Keya; Xiao, Songhua; Liu, Zhengsheng; Zhang, Yonggang; Zhang, Xuesong; Wang, Zheng; Lu, Ning; Shourong, Zhu; Xifeng, Zhang; Geng, Cui; Baowei, Liu

    2010-01-01

    Surgical treatment of complex severe spinal deformity, involving a scoliosis Cobb angle of more than 90° and kyphosis or vertebral and rib deformity, is challenging. Preoperative two-dimensional images resulting from plain film radiography, computed tomography (CT) and magnetic resonance imaging provide limited morphometric information. Although the three-dimensional (3D) reconstruction CT with special software can view the stereo and rotate the spinal image on the screen, it cannot show the full-scale spine and cannot directly be used on the operation table. This study was conducted to investigate the application of computer-designed polystyrene models in the treatment of complex severe spinal deformity. The study involved 16 cases of complex severe spinal deformity treated in our hospital between 1 May 2004 and 31 December 2007; the mean ± SD preoperative scoliosis Cobb angle was 118° ± 27°. The CT scanning digital imaging and communication in medicine (DICOM) data sets of the affected spinal segments were collected for 3D digital reconstruction and rapid prototyping to prepare computer-designed polystyrene models, which were applied in the treatment of these cases. The computer-designed polystyrene models allowed 3D observation and measurement of the deformities directly, which helped the surgeon to perform morphological assessment and communicate with the patient and colleagues. Furthermore, the models also guided the choice and placement of pedicle screws. Moreover, the models were used to aid in virtual surgery and guide the actual surgical procedure. The mean ± SD postoperative scoliosis Cobb angle was 42° ± 32°, and no serious complications such as spinal cord or major vascular injury occurred. The use of computer-designed polystyrene models could provide more accurate morphometric information and facilitate surgical correction of complex severe spinal deformity. PMID:20213294

  3. Use of three-dimensional computer graphic animation to illustrate cleft lip and palate surgery.

    PubMed

    Cutting, C; Oliker, A; Haring, J; Dayan, J; Smith, D

    2002-01-01

    Three-dimensional (3D) computer animation is not commonly used to illustrate surgical techniques. This article describes the surgery-specific processes that were required to produce animations to teach cleft lip and palate surgery. Three-dimensional models were created using CT scans of two Chinese children with unrepaired clefts (one unilateral and one bilateral). We programmed several custom software tools, including an incision tool, a forceps tool, and a fat tool. Three-dimensional animation was found to be particularly useful for illustrating surgical concepts. Positioning the virtual "camera" made it possible to view the anatomy from angles that are impossible to obtain with a real camera. Transparency allows the underlying anatomy to be seen during surgical repair while maintaining a view of the overlaying tissue relationships. Finally, the representation of motion allows modeling of anatomical mechanics that cannot be done with static illustrations. The animations presented in this article can be viewed on-line at http://www.smiletrain.org/programs/virtual_surgery2.htm. Sophisticated surgical procedures are clarified with the use of 3D animation software and customized software tools. The next step in the development of this technology is the creation of interactive simulators that recreate the experience of surgery in a safe, digital environment. Copyright 2003 Wiley-Liss, Inc.

  4. Indoor Navigation using Direction Sensor and Beacons

    NASA Technical Reports Server (NTRS)

    Shields, Joel; Jeganathan, Muthu

    2004-01-01

    A system for indoor navigation of a mobile robot includes (1) modulated infrared beacons at known positions on the walls and ceiling of a room and (2) a cameralike sensor, comprising a wide-angle lens with a position-sensitive photodetector at the focal plane, mounted in a known position and orientation on the robot. The system also includes a computer running special-purpose software that processes the sensor readings to obtain the position and orientation of the robot in all six degrees of freedom in a coordinate system embedded in the room.

  5. An Inviscid Computational Study of the Space Shuttle Orbiter and Several Damaged Configurations

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Merski, N. Ronald (Technical Monitor)

    2004-01-01

    Inviscid aerodynamic characteristics of the Space Shuttle Orbiter were computed in support of the Columbia Accident Investigation. The unstructured grid software FELISA was used and computations were done using freestream conditions corresponding to those in the NASA Langley 20-Inch Mach 6 CF4 tunnel test section. The angle of attack was held constant at 40 degrees. The baseline (undamaged) configuration and a large number of damaged configurations of the Orbiter were studied. Most of the computations were done on a half model. However, one set of computations was done using the full-model to study the effect of sideslip. The differences in the aerodynamic coefficients for the damaged and the baseline configurations were computed. Simultaneously with the computation reported here, tests were being done on a scale model of the Orbiter in the 20-Inch Mach 6 CF4 tunnel to measure the deltas . The present computations complemented the CF4 tunnel test, and provided aerodynamic coefficients of the Orbiter as well as its components. Further, they also provided details of the flow field.

  6. A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bharoto,; Suparno, Nadi; Putra, Edy Giri Rachman

    In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card)more » for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.« less

  7. A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

    NASA Astrophysics Data System (ADS)

    Bharoto, Suparno, Nadi; Putra, Edy Giri Rachman

    2015-04-01

    In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.

  8. Study between anb angle and wits appraisal in cone beam computed tomography (cbct)

    PubMed Central

    Cibrián, Rosa; Gandia, Jose L.; Paredes, Vanessa

    2013-01-01

    Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying the sample according to the anteroposterior relationship, the values obtained of ANB (Class I: 53%; Class II: 37%; Class III: 10%) and Wits (Class I: 35%; Class II: 56%; Class III: 9%) did not coincide, except for the Class III group. However, of the patients classified differently (Class I and Class II patients) by ANB and Wits, a high percentage of individuals (n=22; 49%), had a mesofacial pattern with a mandibular plane angle within normal values. A correlation has been found between ANB and Wits (r=0,262), occlusal plane angle and ANB (r=0,426), and mandibular plane angle and Wits (r=0,242). No correlation was found between either Wits or ANB in relation with the age of the individuals. Conclusions: ANB and Wits must be included in 3D cephalometric analyses as both are necessary to undertake a more accurate diagnosis of the maxillo-mandibular relationship of the patients. Key words:Cone beam computed tomography, ANB, Wits, cephalometrics. PMID:23722136

  9. Design of a projection display screen with vanishing color shift for rear-projection HDTV

    NASA Astrophysics Data System (ADS)

    Liu, Xiu; Zhu, Jin-lin

    1996-09-01

    Using bi-convex cylinder lens with matrix structure, the transmissive projection display screen with high contrast and wider viewing angle has been widely used in large rear projection TV and video projectors, it obtained a inhere color shift and puzzled the designer of display screen for RGB projection tube in-line adjustment. Based on the method of light beam racing, the general software of designing projection display screen has been developed and the computer model of vanishing color shift for rear projection HDTV has bee completed. This paper discussed the practical designing method to vanish the defect of color shift and mentioned the relations between the primary optical parameters of display screen and relative geometry sizes of lens' surface. The distributions of optical gain to viewing angle and the influences on engineering design are briefly analyzed.

  10. 48 CFR 227.7202-4 - Contract clause.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software and Computer Software Documentation 227.7202-4 Contract clause. A specific contract clause governing the Government's rights in commercial computer software or commercial computer software..., release, perform, display, or disclose computer software or computer software documentation shall be...

  11. 48 CFR 227.7202-4 - Contract clause.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software and Computer Software Documentation 227.7202-4 Contract clause. A specific contract clause governing the Government's rights in commercial computer software or commercial computer software..., release, perform, display, or disclose computer software or computer software documentation shall be...

  12. 48 CFR 227.7202-4 - Contract clause.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software and Computer Software Documentation 227.7202-4 Contract clause. A specific contract clause governing the Government's rights in commercial computer software or commercial computer software..., release, perform, display, or disclose computer software or computer software documentation shall be...

  13. 48 CFR 227.7202-4 - Contract clause.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software and Computer Software Documentation 227.7202-4 Contract clause. A specific contract clause governing the Government's rights in commercial computer software or commercial computer software..., release, perform, display, or disclose computer software or computer software documentation shall be...

  14. 48 CFR 227.7202-4 - Contract clause.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software and Computer Software Documentation 227.7202-4 Contract clause. A specific contract clause governing the Government's rights in commercial computer software or commercial computer software..., release, perform, display, or disclose computer software or computer software documentation shall be...

  15. Uses of megavoltage digital tomosynthesis in radiotherapy

    NASA Astrophysics Data System (ADS)

    Sarkar, Vikren

    With the advent of intensity modulated radiotherapy, radiation treatment plans are becoming more conformal to the tumor with the decreasing margins. It is therefore of prime importance that the patient be positioned correctly prior to treatment. Therefore, image guided treatment is necessary for intensity modulated radiotherapy plans to be implemented successfully. Current advanced imaging devices require costly hardware and software upgrade, and radiation imaging solutions, such as cone beam computed tomography, may introduce extra radiation dose to the patient in order to acquire better quality images. Thus, there is a need to extend current existing imaging device ability and functions while reducing cost and radiation dose. Existing electronic portal imaging devices can be used to generate computed tomography-like tomograms through projection images acquired over a small angle using the technique of cone-beam digital tomosynthesis. Since it uses a fraction of the images required for computed tomography reconstruction, use of this technique correspondingly delivers only a fraction of the imaging dose to the patient. Furthermore, cone-beam digital tomosynthesis can be offered as a software-only solution as long as a portal imaging device is available. In this study, the feasibility of performing digital tomosynthesis using individually-acquired megavoltage images from a charge coupled device-based electronic portal imaging device was investigated. Three digital tomosynthesis reconstruction algorithms, the shift-and-add, filtered back-projection, and simultaneous algebraic reconstruction technique, were compared considering the final image quality and radiation dose during imaging. A software platform, DART, was created using a combination of the Matlab and C++ languages. The platform allows for the registration of a reference Cone Beam Digital Tomosynthesis (CBDT) image against a daily acquired set to determine how to shift the patient prior to treatment. Finally, the software was extended to investigate if the digital tomosynthesis dataset could be used in an adaptive radiotherapy regimen through the use of the Pinnacle treatment planning software to recalculate dose delivered. The feasibility study showed that the megavoltage CBDT visually agreed with corresponding megavoltage computed tomography images. The comparative study showed that the best compromise between imaging quality and imaging dose is obtained when 11 projection images, acquired over an imaging angle of 40°, are used with the filtered back-projection algorithm. DART was successfully used to register reference and daily image sets to within 1 mm in-plane and 2.5 mm out of plane. The DART platform was also effectively used to generate updated files that the Pinnacle treatment planning system used to calculate updated dose in a rigidly shifted patient. These doses were then used to calculate a cumulative dose distribution that could be used by a physician as reference to decide when the treatment plan should be updated. In conclusion, this study showed that a software solution is possible to extend existing electronic portal imaging devices to function as cone-beam digital tomosynthesis devices and achieve daily requirement for image guided intensity modulated radiotherapy treatments. The DART platform also has the potential to be used as a part of adaptive radiotherapy solution.

  16. Fast simulation of Proton Induced X-Ray Emission Tomography using CUDA

    NASA Astrophysics Data System (ADS)

    Beasley, D. G.; Marques, A. C.; Alves, L. C.; da Silva, R. C.

    2013-07-01

    A new 3D Proton Induced X-Ray Emission Tomography (PIXE-T) and Scanning Transmission Ion Microscopy Tomography (STIM-T) simulation software has been developed in Java and uses NVIDIA™ Common Unified Device Architecture (CUDA) to calculate the X-ray attenuation for large detector areas. A challenge with PIXE-T is to get sufficient counts while retaining a small beam spot size. Therefore a high geometric efficiency is required. However, as the detector solid angle increases the calculations required for accurate reconstruction of the data increase substantially. To overcome this limitation, the CUDA parallel computing platform was used which enables general purpose programming of NVIDIA graphics processing units (GPUs) to perform computations traditionally handled by the central processing unit (CPU). For simulation performance evaluation, the results of a CPU- and a CUDA-based simulation of a phantom are presented. Furthermore, a comparison with the simulation code in the PIXE-Tomography reconstruction software DISRA (A. Sakellariou, D.N. Jamieson, G.J.F. Legge, 2001) is also shown. Compared to a CPU implementation, the CUDA based simulation is approximately 30× faster.

  17. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    PubMed

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  18. 48 CFR 12.212 - Computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Computer software. 12.212... software. (a) Commercial computer software or commercial computer software documentation shall be acquired... required to— (1) Furnish technical information related to commercial computer software or commercial...

  19. 48 CFR 12.212 - Computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Computer software. 12.212... software. (a) Commercial computer software or commercial computer software documentation shall be acquired... required to— (1) Furnish technical information related to commercial computer software or commercial...

  20. 48 CFR 12.212 - Computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Computer software. 12.212... software. (a) Commercial computer software or commercial computer software documentation shall be acquired... required to— (1) Furnish technical information related to commercial computer software or commercial...

  1. 48 CFR 12.212 - Computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Computer software. 12.212... software. (a) Commercial computer software or commercial computer software documentation shall be acquired... required to— (1) Furnish technical information related to commercial computer software or commercial...

  2. 48 CFR 12.212 - Computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Computer software. 12.212... software. (a) Commercial computer software or commercial computer software documentation shall be acquired... required to— (1) Furnish technical information related to commercial computer software or commercial...

  3. Optimal approach for complete liver tumor ablation using radiofrequency ablation: a simulation study.

    PubMed

    Givehchi, Sogol; Wong, Yin How; Yeong, Chai Hong; Abdullah, Basri Johan Jeet

    2018-04-01

    To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation. The RFA of a spherical tumor of 2.0 cm diameter along with 0.5 cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90° to +90° with 30° increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor. Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles. Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.

  4. Association between third molar agenesis and craniofacial structure development.

    PubMed

    Ramiro-Verdugo, Jara; De Vicente-Corominas, Elena; Montiel-Company, José María; Gandía-Franco, José Luís; Bellot-Arcís, Carlos

    2015-11-01

    The aim of this investigation was to study the relationship between third molar agenesis-including the number of ageneses-and craniofacial structure growth. We reviewed 305 clinical histories of patients treated at the Orthodontics Unit of the Faculty of Medicine and Dentistry at the University of Valencia in Spain. This included radiographic records of optimal quality. Of these, 40 patients who had agenesis of at least 1 third molar were included in the study group. A control group was formed with another 40 patients with all 4 third molars present. For both groups, a further criterion for inclusion was cone-beam computed tomography records. The cephalometric analysis was performed with NemoCeph 3D software (version 11.3.1.38; Nemotec, Madrid, Spain). The only significant differences between the 2 groups were in the total gonial angle and the upper gonial angle (P ≤0.05), both of which were smaller in the study group. Third molar agenesis is associated with a reduction in Jarabak's gonial angle and upper gonial angle, characteristic of patients with a more horizontal or brachyfacial skeletal pattern. No significant differences were found in other measurements. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. Further Refinement of the LEWICE SLD Model

    NASA Technical Reports Server (NTRS)

    Wright, William B.

    2006-01-01

    A research project is underway at NASA Glenn Research Center to produce computer software that can accurately predict ice growth for any meteorological conditions for any aircraft surface. This report will present results from version 3.2 of this software, which is called LEWICE. This version differs from previous releases in that it incorporates additional thermal analysis capabilities, a pneumatic boot model, interfaces to external computational fluid dynamics (CFD) flow solvers and has an empirical model for the supercooled large droplet (SLD) regime. An extensive comparison against the database of ice shapes and collection efficiencies that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has also been performed. The complete set of data used for this comparison will eventually be available in a contractor report. This paper will show the differences in collection efficiency and ice shape between LEWICE 3.2 and experimental data. This report will first describe the LEWICE 3.2 SLD model. A semi-empirical approach was used to incorporate first order physical effects of large droplet phenomena into icing software. Comparisons are then made to every two-dimensional case in the water collection database and the ice shape database. Each collection efficiency condition was run using the following four assumptions: 1) potential flow, no splashing; 2) potential flow, with splashing; 3) Navior-Stokes, no splashing; 4) Navi r-Stokes, with splashing. All cases were run with 21 bin drop size distributions and a lift correction (angle of attack adjustment). Quantitative comparisons are shown for impingement limit, maximum water catch, and total collection efficiency. Due to the large number of ice shape cases, comprehensive comparisons were limited to potential flow cases with and without splashing. Quantitative comparisons are shown for horn height, horn angle, icing limit, area, and leading edge thickness. The results show that the predicted results for both ice shape and water collection are within the accuracy limits of the experimental data for the majority of cases.

  6. Automated analysis of angle closure from anterior chamber angle images.

    PubMed

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  7. Effects of Different Angles of the Traction Table on Lumbar Spine Ligaments: A Finite Element Study.

    PubMed

    Farajpour, Hekmat; Jamshidi, Nima

    2017-12-01

    The traction bed is a noninvasive device for treating lower back pain caused by herniated intervertebral discs. In this study, we investigated the impact of the traction bed on the lower back as a means of increasing the disc height and creating a gap between facet joints. Computed tomography (CT) images were obtained from a female volunteer and a three-dimensional (3D) model was created using software package MIMICs 17.0. Afterwards, the 3D model was analyzed in an analytical software (Abaqus 6.14). The study was conducted under the following traction loads: 25%, 45%, 55%, and 85% of the whole body weight in different angles. Results indicated that the loading angle in the L3-4 area had 36.8%, 57.4%, 55.32%, 49.8%, and 52.15% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 32.3%, 10.6%, 53.4%, 56.58%, and 57.35%. Also, the body weight had 63.2%, 42.6%, 44.68%, 50.2%, and 47.85% effect on the anterior longitudinal ligament, posterior longitudinal ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament, respectively. The respective values for the L4-5 area were 67.7%, 89.4%, 46.6%, 43.42% and 42.65%. The authenticity of results was checked by comparing with the experimental data. The results show that traction beds are highly effective for disc movement and lower back pain relief. Also, an optimal angle for traction can be obtained in a 3D model analysis using CT or magnetic resonance imaging images. The optimal angle would be different for different patients and thus should be determined based on the decreased height of the intervertebral disc, weight and height of patients.

  8. Developing a cosmic ray muon sampling capability for muon tomography and monitoring applications

    NASA Astrophysics Data System (ADS)

    Chatzidakis, S.; Chrysikopoulou, S.; Tsoukalas, L. H.

    2015-12-01

    In this study, a cosmic ray muon sampling capability using a phenomenological model that captures the main characteristics of the experimentally measured spectrum coupled with a set of statistical algorithms is developed. The "muon generator" produces muons with zenith angles in the range 0-90° and energies in the range 1-100 GeV and is suitable for Monte Carlo simulations with emphasis on muon tomographic and monitoring applications. The muon energy distribution is described by the Smith and Duller (1959) [35] phenomenological model. Statistical algorithms are then employed for generating random samples. The inverse transform provides a means to generate samples from the muon angular distribution, whereas the Acceptance-Rejection and Metropolis-Hastings algorithms are employed to provide the energy component. The predictions for muon energies 1-60 GeV and zenith angles 0-90° are validated with a series of actual spectrum measurements and with estimates from the software library CRY. The results confirm the validity of the phenomenological model and the applicability of the statistical algorithms to generate polyenergetic-polydirectional muons. The response of the algorithms and the impact of critical parameters on computation time and computed results were investigated. Final output from the proposed "muon generator" is a look-up table that contains the sampled muon angles and energies and can be easily integrated into Monte Carlo particle simulation codes such as Geant4 and MCNP.

  9. Computation of Femoral Canine Morphometric Parameters in Three-Dimensional Geometrical Models.

    PubMed

    Savio, Gianpaolo; Baroni, Teresa; Concheri, Gianmaria; Baroni, Ermenegildo; Meneghello, Roberto; Longo, Federico; Isola, Maurizio

    2016-11-01

    To define and validate a method for the measurement of 3-dimensional (3D) morphometric parameters in polygonal mesh models of canine femora. Ex vivo/computerized model. Sixteen femora from 8 medium to large-breed canine cadavers (mean body weight 28.3 kg, mean age 5.3 years). Femora were measured with a 3D scanner, obtaining 3D meshes. A computer-aided design-based (CAD) software tool was purposely developed, which allowed automatic calculation of morphometric parameters on a mesh model. Anatomic and mechanical lateral proximal femoral angles (aLPFA and mLPFA), anatomic and mechanical lateral distal femoral angles (aLDFA and mLDFA), femoral neck angle (FNA), femoral torsion angle (FTA), and femoral varus angle (FVA) were measured in 3D space. Angles were also measured onto projected planes and radiographic images. Mean (SD) femoral angles (degrees) measured in 3D space were: aLPFA 115.2 (3.9), mLPFA 105.5 (4.2), aLDFA 88.6 (4.5), mLDFA 93.4 (3.9), FNA 129.6 (4.3), FTA 45 (4.5), and FVA -1.4 (4.5). Onto projection planes, aLPFA was 103.7 (5.9), mLPFA 98.4 (5.3), aLDFA 88.3 (5.5), mLDFA 93.6 (4.2), FNA 132.1 (3.5), FTA 19.1 (5.7), and FVA -1.7 (5.5). With radiographic imaging, aLPFA was 109.6 (5.9), mLPFA 105.3 (5.2), aLDFA 92.6 (3.8), mLDFA 96.9 (2.9), FNA 120.2 (8.0), FTA 30.2 (5.7), and FVA 2.6 (3.8). The proposed method gives reliable and consistent information about 3D bone conformation. Results are obtained automatically and depend only on femur morphology, avoiding any operator-related bias. Angles in 3D space are different from those measured with standard radiographic methods, mainly due to the different definition of femoral axes. © Copyright 2016 by The American College of Veterinary Surgeons.

  10. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials.

    PubMed

    DeLong, R; Pintado, M R; Ko, C C; Hodges, J S; Douglas, W H

    2001-06-01

    Future growth in dental practice lies in digital imaging enhancing many chairside procedures and functions. This revolution requires the fast, accurate, and 3D digitizing of clinical records. One such clinical record is the chairside impression. This study investigated how surface angle and surface roughness affect the digitizing of vinyl polysiloxane impression materials. Seventeen vinyl polysiloxane impression materials were digitized with a white light optical digitizing system. Each sample was digitized at 3 different angles: 0 degrees, 22.5 degrees, and 45 degrees, and 2 digitizer camera f-stops. The digitized images were rendered on a computer monitor using custom software developed under NIH/NIDCR grant DE12225. All the 3D images were rotated to the 0 degrees position, cropped using Corel Photo-Paint 8 (Corel Corp, Ottawa, Ontario, Canada), then saved in the TIFF file format. The impression material area that was successfully digitized was calculated as a percentage of the total sample area, using Optimas 5.22 image processing software (Media Cybernetics, LP, Silver Spring, MD). The dependent variable was a Performance Value calculated for each material by averaging the percentage of area that digitized over the 3 angles. New samples with smooth and rough surfaces were made using the 7 impression materials with the largest Performance Values. These samples were tested as before, but with the additional angle of 60 degrees. Silky-Rock die stone (Whip Mix Corp, Louisville, KY) was used as a control. The Performance Values for the 17 impression materials ranged from 0% to 100%. The Performance Values for the 7 best materials were equivalent to the control at f/11 out to a surface angle of 45 degrees; however, only Examix impression material (GC America Inc, Alsip, IL) was equivalent to the control at f/11/\\16. At the 60 degrees surface angle with f/11/\\16, the Performance Values were 0% for all the impression materials, whereas that for the control was 90%. The difference in the Performance Values for the smooth and rough surface textures was 7%, which was not significant. The digitizing performance of vinyl polysiloxane impression materials is highly material and surface angle-dependent and is significantly lower than the die stone control when angles to 60 degrees are included. It is affected to a lesser extent by surface texture. Copyright 2001 by The American College of Prosthodontists.

  11. Determining Angle of Humeral Torsion Using Image Software Technique.

    PubMed

    Patil, Sachin; Sethi, Madhu; Vasudeva, Neelam

    2016-10-01

    Several researches have been done on the measurement of angles of humeral torsion in different parts of the world. Previously described methods were more complicated, not much accurate, cumbersome or required sophisticated instruments. The present study was conducted with the aim to determine the angles of humeral torsion with a newer simple technique using digital images and image tool software. A total of 250 dry normal adult human humeri were obtained from the bone bank of Department of Anatomy. The length and mid-shaft circumference of each bone was measured with the help of measuring tape. The angle of humeral torsion was measured directly from the digital images by the image analysis using Image Tool 3.0 software program. The data was analysed statistically with SPSS version 17 using unpaired t-test and Spearman's rank order correlation coefficient. The mean angle of torsion was 64.57°±7.56°. On the right side it was 66.84°±9.69°, whereas, on the left side it was found to be 63.31±9.50°. The mean humeral length was 31.6 cm on right side and 30.33 cm on left side. Mid shaft circumference was 5.79 on right side and 5.63 cm on left side. No statistical differences were seen in angles between right and left humeri (p>0.001). From our study, it was concluded that circumference of shaft is inversely proportional to angle of humeral torsion. The length and side of humerus has no relation with the humeral torsion. With advancement of digital technology, it is better to use new image softwares for anatomical studies.

  12. Wildlife software: procedures for publication of computer software

    USGS Publications Warehouse

    Samuel, M.D.

    1990-01-01

    Computers and computer software have become an integral part of the practice of wildlife science. Computers now play an important role in teaching, research, and management applications. Because of the specialized nature of wildlife problems, specific computer software is usually required to address a given problem (e.g., home range analysis). This type of software is not usually available from commercial vendors and therefore must be developed by those wildlife professionals with particular skill in computer programming. Current journal publication practices generally prevent a detailed description of computer software associated with new techniques. In addition, peer review of journal articles does not usually include a review of associated computer software. Thus, many wildlife professionals are usually unaware of computer software that would meet their needs or of major improvements in software they commonly use. Indeed most users of wildlife software learn of new programs or important changes only by word of mouth.

  13. Fostering Students' Development of the Concept of Angles Using Technology

    ERIC Educational Resources Information Center

    Richardson, Sue Ellen; Koyunkaya, Melike Yigit

    2017-01-01

    We have used "GeoGebra," a dynamic geometry software environment, to explore how Year 4 students understand definitions of angles. Seven students defined angle and then completed several activities adapted for the dynamic environment. Afterward, students again shared their definitions of angles. We found that even a short investigation…

  14. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters

    PubMed Central

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915measuredsamples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rateand heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08. PMID:26624613

  15. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters.

    PubMed

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915 measured samples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rate and heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08.

  16. 48 CFR 227.7203-17 - Overseas contracts with foreign sources.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-17 Overseas contracts with foreign sources. (a) The clause at 252.227-7032, Rights in Technical Data and Computer Software... Noncommercial Computer Software and Noncommercial Computer Software Documentation, when the Government requires...

  17. 48 CFR 227.7203-17 - Overseas contracts with foreign sources.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-17 Overseas contracts with foreign sources. (a) The clause at 252.227-7032, Rights in Technical Data and Computer Software... Noncommercial Computer Software and Noncommercial Computer Software Documentation, when the Government requires...

  18. 48 CFR 227.7203-17 - Overseas contracts with foreign sources.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-17 Overseas contracts with foreign sources. (a) The clause at 252.227-7032, Rights in Technical Data and Computer Software... Noncommercial Computer Software and Noncommercial Computer Software Documentation, when the Government requires...

  19. 48 CFR 227.7203-17 - Overseas contracts with foreign sources.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-17 Overseas contracts with foreign sources. (a) The clause at 252.227-7032, Rights in Technical Data and Computer Software... Noncommercial Computer Software and Noncommercial Computer Software Documentation, when the Government requires...

  20. 48 CFR 227.7203-17 - Overseas contracts with foreign sources.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-17 Overseas contracts with foreign sources. (a) The clause at 252.227-7032, Rights in Technical Data and Computer Software... Noncommercial Computer Software and Noncommercial Computer Software Documentation, when the Government requires...

  1. WAMDII: The Wide Angle Michelson Doppler Imaging Interferometer

    NASA Technical Reports Server (NTRS)

    1992-01-01

    As part of an effort to learn more about the upper atmosphere and how it is linked to the weather experienced each day, NASA and NRCC are jointly sponsoring the Wide Angle Michelson Doppler Imaging Interferometer (WAMDII) Mission. WAMDII will measure atmospheric temperature and wind speed in the upper atmosphere. In addition to providing data on the upper atmosphere, the wind speed and temperature readings WAMDII takes will also be highly useful in developing and updating computer simulated models of the upper atmosphere. These models are used in the design and testing of equipment and software for Shuttles, satellites, and reentry vehicles. In making its wind speed and temperature measurements, WAMDII examines the Earth's airglow, a faint photochemical luminescence caused by the influx of solar ultraviolet energy into the upper atmosphere. During periods of high solar flare activity, the amount of this UV energy entering the upper atmosphere increases, and this increase may effect airglow emissions.

  2. Modification of silicon nitride surfaces with GOPES and APTES for antibody immobilization: computational and experimental studies

    NASA Astrophysics Data System (ADS)

    Dien To, Thien; Nguyen, Anh Tuan; Nhat Thanh Phan, Khoa; Thu Thi Truong, An; Doan, Tin Chanh Duc; Mau Dang, Chien

    2015-12-01

    Chemical modification of silicon nitride (SiN) surfaces by silanization has been widely studied especially with 3-(aminopropyl)triethoxysilane (APTES) and 3-(glycidyloxypropyl) dimethylethoxysilane (GOPES). However few reports performed the experimental and computational studies together. In this study, surface modification of SiN surfaces with GOPES and APTES covalently bound with glutaraldehyde (GTA) was investigated for antibody immobilization. The monoclonal anti-cytokeratin-FITC (MACF) antibody was immobilized on the modified SiN surfaces. The modified surfaces were characterized by water contact angle measurements, atomic force microscopy and fluorescence microscopy. The FITC-fluorescent label indicated the existence of MACF antibody on the SiN surfaces and the efficiency of the silanization reaction. Absorption of APTES and GOPES on the oxidized SiN surfaces was computationally modeled and calculated by Materials Studio software. The computational and experimental results showed that modification of the SiN surfaces with APTES and GTA was more effective than the modification with GOPES.

  3. Monitoring and Controlling an Underwater Robotic Arm

    NASA Technical Reports Server (NTRS)

    Haas, John; Todd, Brian Keith; Woodcock, Larry; Robinson, Fred M.

    2009-01-01

    The SSRMS Module 1 software is part of a system for monitoring an adaptive, closed-loop control of the motions of a robotic arm in NASA s Neutral Buoyancy Laboratory, where buoyancy in a pool of water is used to simulate the weightlessness of outer space. This software is so named because the robot arm is a replica of the Space Shuttle Remote Manipulator System (SSRMS). This software is distributed, running on remote joint processors (RJPs), each of which is mounted in a hydraulic actuator comprising the joint of the robotic arm and communicating with a poolside processor denoted the Direct Control Rack (DCR). Each RJP executes the feedback joint-motion control algorithm for its joint and communicates with the DCR. The DCR receives joint-angular-velocity commands either locally from an operator or remotely from computers that simulate the flight like SSRMS and perform coordinated motion calculations based on hand-controller inputs. The received commands are checked for validity before they are transmitted to the RJPs. The DCR software generates a display of the statuses of the RJPs for the DCR operator and can shut down the hydraulic pump when excessive joint-angle error or failure of a RJP is detected.

  4. Optical system design, analysis, and production; Proceedings of the Meeting, Geneva, Switzerland, April 19-22, 1983

    NASA Astrophysics Data System (ADS)

    Rogers, P. J.; Fischer, R. E.

    1983-01-01

    Topics considered include: optical system requirements, analysis, and system engineering; optical system design using microcomputers and minicomputers; optical design theory and computer programs; optical design methods and computer programs; optical design methods and philosophy; unconventional optical design; diffractive and gradient index optical system design; optical production and system integration; and optical systems engineering. Particular attention is given to: stray light control as an integral part of optical design; current and future directions of lens design software; thin-film technology in the design and production of optical systems; aspherical lenses in optical scanning systems; the application of volume phase holograms to avionic displays; the effect of lens defects on thermal imager performance; and a wide angle zoom for the Space Shuttle.

  5. AGAMA: Action-based galaxy modeling framework

    NASA Astrophysics Data System (ADS)

    Vasiliev, Eugene

    2018-05-01

    The AGAMA library models galaxies. It computes gravitational potential and forces, performs orbit integration and analysis, and can convert between position/velocity and action/angle coordinates. It offers a framework for finding best-fit parameters of a model from data and self-consistent multi-component galaxy models, and contains useful auxiliary utilities such as various mathematical routines. The core of the library is written in C++, and there are Python and Fortran interfaces. AGAMA may be used as a plugin for the stellar-dynamical software packages galpy (ascl:1411.008), AMUSE (ascl:1107.007), and NEMO (ascl:1010.051).

  6. FT-IR, Laser-Raman spectra and computational analysis of 5-Methyl-3-phenylisoxazole-4-carboxylic acid.

    PubMed

    Sert, Yusuf; Mahendra, M; Keskinoğlu, S; Chandra; Srikantamurthy, N; Umesha, K B; Çırak, Ç

    2015-03-15

    In this study the experimental and theoretical vibrational frequencies of a newly synthesized anti-tumor, antiviral, hypoglycemic, antifungal and anti-HIV agent namely, 5-Methyl-3-phenylisoxazole-4-carboxylic acid has been investigated. The experimental FT-IR (4000-400 cm(-1)) and Laser-Raman spectra (4000-100 cm(-1)) of the molecule in solid phase have been recorded. The theoretical vibrational frequencies and optimized geometric parameters (bond lengths, bond angles and torsion angles) have been calculated by using density functional theory (DFT/B3LYP: Becke, 3-parameter, Lee-Yang-Parr and DFT/M06-2X: highly parametrized, empirical exchange correlation function) with 6-311++G(d,p) basis set by Gaussian 09W software, for the first time. The assignments of the vibrational frequencies have been done by potential energy distribution (PED) analysis by using VEDA 4 software. The theoretical optimized geometric parameters and vibrational frequencies have been found to be in good agreement with the corresponding experimental data and results in the literature. In addition, the highest occupied molecular orbital (HOMO) energy, the lowest unoccupied molecular orbital (LUMO) energy and the other related molecular energy values of the compound have been investigated by using the same theoretical calculations. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. FT-IR, Laser-Raman spectra and computational analysis of 5-Methyl-3-phenylisoxazole-4-carboxylic acid

    NASA Astrophysics Data System (ADS)

    Sert, Yusuf; Mahendra, M.; Keskinoğlu, S.; Chandra; Srikantamurthy, N.; Umesha, K. B.; Çırak, Ç.

    2015-03-01

    In this study the experimental and theoretical vibrational frequencies of a newly synthesized anti-tumor, antiviral, hypoglycemic, antifungal and anti-HIV agent namely, 5-Methyl-3-phenylisoxazole-4-carboxylic acid has been investigated. The experimental FT-IR (4000-400 cm-1) and Laser-Raman spectra (4000-100 cm-1) of the molecule in solid phase have been recorded. The theoretical vibrational frequencies and optimized geometric parameters (bond lengths, bond angles and torsion angles) have been calculated by using density functional theory (DFT/B3LYP: Becke, 3-parameter, Lee-Yang-Parr and DFT/M06-2X: highly parametrized, empirical exchange correlation function) with 6-311++G(d,p) basis set by Gaussian 09W software, for the first time. The assignments of the vibrational frequencies have been done by potential energy distribution (PED) analysis by using VEDA 4 software. The theoretical optimized geometric parameters and vibrational frequencies have been found to be in good agreement with the corresponding experimental data and results in the literature. In addition, the highest occupied molecular orbital (HOMO) energy, the lowest unoccupied molecular orbital (LUMO) energy and the other related molecular energy values of the compound have been investigated by using the same theoretical calculations.

  8. A "Kane's Dynamics" Model for the Active Rack Isolation System Part Two: Nonlinear Model Development, Verification, and Simplification

    NASA Technical Reports Server (NTRS)

    Beech, G. S.; Hampton, R. D.; Rupert, J. K.

    2004-01-01

    Many microgravity space-science experiments require vibratory acceleration levels that are unachievable without active isolation. The Boeing Corporation's active rack isolation system (ARIS) employs a novel combination of magnetic actuation and mechanical linkages to address these isolation requirements on the International Space Station. Effective model-based vibration isolation requires: (1) An isolation device, (2) an adequate dynamic; i.e., mathematical, model of that isolator, and (3) a suitable, corresponding controller. This Technical Memorandum documents the validation of that high-fidelity dynamic model of ARIS. The verification of this dynamics model was achieved by utilizing two commercial off-the-shelf (COTS) software tools: Deneb's ENVISION(registered trademark), and Online Dynamics Autolev(trademark). ENVISION is a robotics software package developed for the automotive industry that employs three-dimensional computer-aided design models to facilitate both forward and inverse kinematics analyses. Autolev is a DOS-based interpreter designed, in general, to solve vector-based mathematical problems and specifically to solve dynamics problems using Kane's method. The simplification of this model was achieved using the small-angle theorem for the joint angle of the ARIS actuators. This simplification has a profound effect on the overall complexity of the closed-form solution while yielding a closed-form solution easily employed using COTS control hardware.

  9. Inverse Flush Air Data System (FADS) for Real Time Simulations

    NASA Astrophysics Data System (ADS)

    Madhavanpillai, Jayakumar; Dhoaya, Jayanta; Balakrishnan, Vidya Saraswathi; Narayanan, Remesh; Chacko, Finitha Kallely; Narayanan, Shyam Mohan

    2017-12-01

    Flush Air Data Sensing System (FADS) forms a mission critical sub system in future reentry vehicles. FADS makes use of surface pressure measurements from the nose cap of the vehicle for deriving the air data parameters of the vehicle such as angle of attack, angle of sideslip, Mach number, etc. These parameters find use in the flight control and guidance systems, and also assist in the overall mission management. The FADS under consideration in this paper makes use of nine pressure ports located in the nose cap of a technology demonstrator vehicle. In flight, the air data parameters are obtained from the FADS estimation algorithm using the pressure data at the nine pressure ports. But, these pressure data will not be available, for testing the FADS package during ground simulation. So, an inverse software to FADS which estimates the pressure data at the pressure ports for a given flight condition is developed. These pressure data at the nine ports will go as input to the FADS package during ground simulation. The software is run to generate the pressure data for the descent phase trajectory of the technology demonstrator. This data is used again to generate the air data parameters from FADS algorithm. The computed results from FADS algorithm match well with the trajectory data.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flores, Alejandra Parra; Bravo, Oscar Martinez; Ibargueen, Humberto Salazar

    The purpose of this work is to show the results of the analysis of a library of synthetic data corresponding to Very Inclined Showers (i.e. those with a zenith angle between 60 and 80 degrees and energies from 50 EeV to 80 EeV). Simulations were performed using the Aires software and then analyzed to narrow down the arrival angles that allow us an efficient shower reconstruction using the Offline software.

  11. 48 CFR 252.227-7027 - Deferred ordering of technical data or computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... technical data or computer software. 252.227-7027 Section 252.227-7027 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(b), use the following clause: Deferred Ordering of Technical Data or Computer Software (APR 1988) In addition to technical data or computer software...

  12. 48 CFR 252.227-7027 - Deferred ordering of technical data or computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... technical data or computer software. 252.227-7027 Section 252.227-7027 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(b), use the following clause: Deferred Ordering of Technical Data or Computer Software (APR 1988) In addition to technical data or computer software...

  13. 48 CFR 252.227-7027 - Deferred ordering of technical data or computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... technical data or computer software. 252.227-7027 Section 252.227-7027 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(b), use the following clause: Deferred Ordering of Technical Data or Computer Software (APR 1988) In addition to technical data or computer software...

  14. 48 CFR 252.227-7027 - Deferred ordering of technical data or computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... technical data or computer software. 252.227-7027 Section 252.227-7027 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(b), use the following clause: Deferred Ordering of Technical Data or Computer Software (APR 1988) In addition to technical data or computer software...

  15. 48 CFR 252.227-7027 - Deferred ordering of technical data or computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technical data or computer software. 252.227-7027 Section 252.227-7027 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(b), use the following clause: Deferred Ordering of Technical Data or Computer Software (APR 1988) In addition to technical data or computer software...

  16. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

    PubMed

    Zhang, Yuan Z; Chen, Bin; Lu, Sheng; Yang, Yong; Zhao, Jian M; Liu, Rui; Li, Yan B; Pei, Guo X

    2011-12-01

    The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05). The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate location of prosthesis with a low cost-performance ratio without excessive technical workload on the surgical team. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Space Trajectory Error Analysis Program (STEAP) for halo orbit missions. Volume 2: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Byrnes, D. V.; Carney, P. C.; Underwood, J. W.; Vogt, E. D.

    1974-01-01

    The six month effort was responsible for the development, test, conversion, and documentation of computer software for the mission analysis of missions to halo orbits about libration points in the earth-sun system. The software consisting of two programs called NOMNAL and ERRAN is part of the Space Trajectories Error Analysis Programs. The program NOMNAL targets a transfer trajectory from earth on a given launch date to a specified halo orbit on a required arrival date. Either impulsive or finite thrust insertion maneuvers into halo orbit are permitted by the program. The transfer trajectory is consistent with a realistic launch profile input by the user. The second program ERRAN conducts error analyses of the targeted transfer trajectory. Measurements including range, doppler, star-planet angles, and apparent planet diameter are processed in a Kalman-Schmidt filter to determine the trajectory knowledge uncertainty.

  18. 48 CFR 227.7203-1 - Policy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-1 Policy. (a) DoD policy is to acquire only the computer software and computer software documentation, and the rights in such software or documentation, necessary...

  19. 48 CFR 227.7203-1 - Policy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-1 Policy. (a) DoD policy is to acquire only the computer software and computer software documentation, and the rights in such software or documentation, necessary...

  20. 48 CFR 227.7203-1 - Policy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-1 Policy. (a) DoD policy is to acquire only the computer software and computer software documentation, and the rights in such software or documentation, necessary...

  1. 48 CFR 227.7203-1 - Policy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-1 Policy. (a) DoD policy is to acquire only the computer software and computer software documentation, and the rights in such software or documentation, necessary...

  2. 48 CFR 227.7203-1 - Policy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-1 Policy. (a) DoD policy is to acquire only the computer software and computer software documentation, and the rights in such software or documentation, necessary...

  3. 48 CFR 227.7205 - Contracts for special works.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Computer Software and Computer Software Documentation 227.7205 Contracts for special works. (a) Use the... a specific need to control the distribution of computer software or computer software documentation..., modification, reproduction, release, performance, display, or disclosure of such software or documentation. Use...

  4. 48 CFR 227.7205 - Contracts for special works.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Computer Software and Computer Software Documentation 227.7205 Contracts for special works. (a) Use the... a specific need to control the distribution of computer software or computer software documentation..., modification, reproduction, release, performance, display, or disclosure of such software or documentation. Use...

  5. [Study of the relationship between congenital missing of the third molar and the development of the mandibular angle].

    PubMed

    Chen, Yan-Na; Zheng, Bo-Wen; Liu, Yi

    2017-02-01

    Based on the research of the congenital missing of the third molar and the missing number, the relationship beteen congenital missing of the third molar and the development of the mandibular angle was evaluated. Patients were divided into experimental group and control group, the experimental group included 227 patients, each had at least one of the third molars congenital lost; 227 patients who had four third molar were selected as control group. Winceph software was used to measure the lateral cephalograms. SPSS17.0 software package was used to perform statistical analysis. Gonial angle, upper Gonial angle and lower Gonial angle between the experimental group and the control group showed significant difference and the values in the experimental group were significantly smaller than in the control group, but there was no gender difference between the two groups.There was no difference between Gonial angle, upper Gonial angle,lower Gonial angle and the missing number of the third molar. There is a close relationship between congenital missing third molar and Gonial angle, upper Gonial angle, lower Gonial angle, but there is no significant association with gender and the patients with congenital missing third molar have shorter craniofacial structure. Congenital missing number of the third molar has no significant association with Gonial angle, upper Gonial angle and lower Gonial angle.

  6. 48 CFR 227.7203-6 - Contract clauses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software and Computer Software Documentation 227.7203-6 Contract clauses. (a)(1) Use the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, in solicitations and contracts when the successful offeror(s) will be required to deliver computer software or...

  7. 48 CFR 227.7203-6 - Contract clauses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software and Computer Software Documentation 227.7203-6 Contract clauses. (a)(1) Use the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, in solicitations and contracts when the successful offeror(s) will be required to deliver computer software or...

  8. 48 CFR 227.7203-6 - Contract clauses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software and Computer Software Documentation 227.7203-6 Contract clauses. (a)(1) Use the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, in solicitations and contracts when the successful offeror(s) will be required to deliver computer software or...

  9. 48 CFR 227.7203-6 - Contract clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software and Computer Software Documentation 227.7203-6 Contract clauses. (a)(1) Use the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, in solicitations and contracts when the successful offeror(s) will be required to deliver computer software or...

  10. 48 CFR 227.7203-6 - Contract clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software and Computer Software Documentation 227.7203-6 Contract clauses. (a)(1) Use the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, in solicitations and contracts when the successful offeror(s) will be required to deliver computer software or...

  11. Stochastic Evolutionary Algorithms for Planning Robot Paths

    NASA Technical Reports Server (NTRS)

    Fink, Wolfgang; Aghazarian, Hrand; Huntsberger, Terrance; Terrile, Richard

    2006-01-01

    A computer program implements stochastic evolutionary algorithms for planning and optimizing collision-free paths for robots and their jointed limbs. Stochastic evolutionary algorithms can be made to produce acceptably close approximations to exact, optimal solutions for path-planning problems while often demanding much less computation than do exhaustive-search and deterministic inverse-kinematics algorithms that have been used previously for this purpose. Hence, the present software is better suited for application aboard robots having limited computing capabilities (see figure). The stochastic aspect lies in the use of simulated annealing to (1) prevent trapping of an optimization algorithm in local minima of an energy-like error measure by which the fitness of a trial solution is evaluated while (2) ensuring that the entire multidimensional configuration and parameter space of the path-planning problem is sampled efficiently with respect to both robot joint angles and computation time. Simulated annealing is an established technique for avoiding local minima in multidimensional optimization problems, but has not, until now, been applied to planning collision-free robot paths by use of low-power computers.

  12. Wireless Orbiter Hang-Angle Inclinometer System

    NASA Technical Reports Server (NTRS)

    Lucena, Angel; Perotti, Jose; Green, Eric; Byon, Jonathan; Burns, Bradley; Mata, Carlos; Randazzo, John; Blalock, Norman

    2011-01-01

    A document describes a system to reliably gather the hang-angle inclination of the orbiter. The system comprises a wireless handheld master station (which contains the main station software) and a wireless remote station (which contains the inclinometer sensors, the RF transceivers, and the remote station software). The remote station is designed to provide redundancy to the system. It includes two RF transceivers, two power-management boards, and four inclinometer sensors.

  13. 48 CFR 52.227-14 - Rights in Data-General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software. Computer software—(1) Means (i) Computer programs that comprise a series of instructions, rules... or computer software documentation. Computer software documentation means owner's manuals, user's... medium, that explain the capabilities of the computer software or provide instructions for using the...

  14. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    PubMed

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. 48 CFR 227.7203-9 - Copyright.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software and Computer Software Documentation 227.7203-9 Copyright. (a) Copyright license. (1) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software... Government to reproduce the software or documentation, distribute copies, perform or display the software or...

  16. 48 CFR 227.7203-9 - Copyright.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software and Computer Software Documentation 227.7203-9 Copyright. (a) Copyright license. (1) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software... Government to reproduce the software or documentation, distribute copies, perform or display the software or...

  17. 48 CFR 227.7203-9 - Copyright.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software and Computer Software Documentation 227.7203-9 Copyright. (a) Copyright license. (1) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software... Government to reproduce the software or documentation, distribute copies, perform or display the software or...

  18. 48 CFR 227.7203-9 - Copyright.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software and Computer Software Documentation 227.7203-9 Copyright. (a) Copyright license. (1) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software... Government to reproduce the software or documentation, distribute copies, perform or display the software or...

  19. 48 CFR 227.7203-9 - Copyright.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software and Computer Software Documentation 227.7203-9 Copyright. (a) Copyright license. (1) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software... Government to reproduce the software or documentation, distribute copies, perform or display the software or...

  20. Image processing with cellular nonlinear networks implemented on field-programmable gate arrays for real-time applications in nuclear fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palazzo, S.; Vagliasindi, G.; Arena, P.

    2010-08-15

    In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested inmore » an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.« less

  1. Uncertainty Analysis for a Jet Flap Airfoil

    NASA Technical Reports Server (NTRS)

    Green, Lawrence L.; Cruz, Josue

    2006-01-01

    An analysis of variance (ANOVA) study was performed to quantify the potential uncertainties of lift and pitching moment coefficient calculations from a computational fluid dynamics code, relative to an experiment, for a jet flap airfoil configuration. Uncertainties due to a number of factors including grid density, angle of attack and jet flap blowing coefficient were examined. The ANOVA software produced a numerical model of the input coefficient data, as functions of the selected factors, to a user-specified order (linear, 2-factor interference, quadratic, or cubic). Residuals between the model and actual data were also produced at each of the input conditions, and uncertainty confidence intervals (in the form of Least Significant Differences or LSD) for experimental, computational, and combined experimental / computational data sets were computed. The LSD bars indicate the smallest resolvable differences in the functional values (lift or pitching moment coefficient) attributable solely to changes in independent variable, given just the input data points from selected data sets. The software also provided a collection of diagnostics which evaluate the suitability of the input data set for use within the ANOVA process, and which examine the behavior of the resultant data, possibly suggesting transformations which should be applied to the data to reduce the LSD. The results illustrate some of the key features of, and results from, the uncertainty analysis studies, including the use of both numerical (continuous) and categorical (discrete) factors, the effects of the number and range of the input data points, and the effects of the number of factors considered simultaneously.

  2. Evolutionary Computing Methods for Spectral Retrieval

    NASA Technical Reports Server (NTRS)

    Terrile, Richard; Fink, Wolfgang; Huntsberger, Terrance; Lee, Seugwon; Tisdale, Edwin; VonAllmen, Paul; Tinetti, Geivanna

    2009-01-01

    A methodology for processing spectral images to retrieve information on underlying physical, chemical, and/or biological phenomena is based on evolutionary and related computational methods implemented in software. In a typical case, the solution (the information that one seeks to retrieve) consists of parameters of a mathematical model that represents one or more of the phenomena of interest. The methodology was developed for the initial purpose of retrieving the desired information from spectral image data acquired by remote-sensing instruments aimed at planets (including the Earth). Examples of information desired in such applications include trace gas concentrations, temperature profiles, surface types, day/night fractions, cloud/aerosol fractions, seasons, and viewing angles. The methodology is also potentially useful for retrieving information on chemical and/or biological hazards in terrestrial settings. In this methodology, one utilizes an iterative process that minimizes a fitness function indicative of the degree of dissimilarity between observed and synthetic spectral and angular data. The evolutionary computing methods that lie at the heart of this process yield a population of solutions (sets of the desired parameters) within an accuracy represented by a fitness-function value specified by the user. The evolutionary computing methods (ECM) used in this methodology are Genetic Algorithms and Simulated Annealing, both of which are well-established optimization techniques and have also been described in previous NASA Tech Briefs articles. These are embedded in a conceptual framework, represented in the architecture of the implementing software, that enables automatic retrieval of spectral and angular data and analysis of the retrieved solutions for uniqueness.

  3. Computational Aerodynamic Analysis of Three-Dimensional Ice Shapes on a NACA 23012 Airfoil

    NASA Technical Reports Server (NTRS)

    Jun, GaRam; Oliden, Daniel; Potapczuk, Mark G.; Tsao, Jen-Ching

    2014-01-01

    The present study identifies a process for performing computational fluid dynamic calculations of the flow over full three-dimensional (3D) representations of complex ice shapes deposited on aircraft surfaces. Rime and glaze icing geometries formed on a NACA23012 airfoil were obtained during testing in the NASA Glenn Research Centers Icing Research Tunnel (IRT). The ice shape geometries were scanned as a cloud of data points using a 3D laser scanner. The data point clouds were meshed using Geomagic software to create highly accurate models of the ice surface. The surface data was imported into Pointwise grid generation software to create the CFD surface and volume grids. It was determined that generating grids in Pointwise for complex 3D icing geometries was possible using various techniques that depended on the ice shape. Computations of the flow fields over these ice shapes were performed using the NASA National Combustion Code (NCC). Results for a rime ice shape for angle of attack conditions ranging from 0 to 10 degrees and for freestream Mach numbers of 0.10 and 0.18 are presented. For validation of the computational results, comparisons were made to test results from rapid-prototype models of the selected ice accretion shapes, obtained from a separate study in a subsonic wind tunnel at the University of Illinois at Urbana-Champaign. The computational and experimental results were compared for values of pressure coefficient and lift. Initial results show fairly good agreement for rime ice accretion simulations across the range of conditions examined. The glaze ice results are promising but require some further examination.

  4. Computational Aerodynamic Analysis of Three-Dimensional Ice Shapes on a NACA 23012 Airfoil

    NASA Technical Reports Server (NTRS)

    Jun, Garam; Oliden, Daniel; Potapczuk, Mark G.; Tsao, Jen-Ching

    2014-01-01

    The present study identifies a process for performing computational fluid dynamic calculations of the flow over full three-dimensional (3D) representations of complex ice shapes deposited on aircraft surfaces. Rime and glaze icing geometries formed on a NACA23012 airfoil were obtained during testing in the NASA Glenn Research Center's Icing Research Tunnel (IRT). The ice shape geometries were scanned as a cloud of data points using a 3D laser scanner. The data point clouds were meshed using Geomagic software to create highly accurate models of the ice surface. The surface data was imported into Pointwise grid generation software to create the CFD surface and volume grids. It was determined that generating grids in Pointwise for complex 3D icing geometries was possible using various techniques that depended on the ice shape. Computations of the flow fields over these ice shapes were performed using the NASA National Combustion Code (NCC). Results for a rime ice shape for angle of attack conditions ranging from 0 to 10 degrees and for freestream Mach numbers of 0.10 and 0.18 are presented. For validation of the computational results, comparisons were made to test results from rapid-prototype models of the selected ice accretion shapes, obtained from a separate study in a subsonic wind tunnel at the University of Illinois at Urbana-Champaign. The computational and experimental results were compared for values of pressure coefficient and lift. Initial results show fairly good agreement for rime ice accretion simulations across the range of conditions examined. The glaze ice results are promising but require some further examination.

  5. Play dough as an educational tool for visualization of complicated cerebral aneurysm anatomy.

    PubMed

    Eftekhar, Behzad; Ghodsi, Mohammad; Ketabchi, Ebrahim; Ghazvini, Arman Rakan

    2005-05-10

    Imagination of the three-dimensional (3D) structure of cerebral vascular lesions using two-dimensional (2D) angiograms is one of the skills that neurosurgical residents should achieve during their training. Although ongoing progress in computer software and digital imaging systems has facilitated viewing and interpretation of cerebral angiograms enormously, these facilities are not always available. We have presented the use of play dough as an adjunct to the teaching armamentarium for training in visualization of cerebral aneurysms in some cases. The advantages of play dough are low cost, availability and simplicity of use, being more efficient and realistic in training the less experienced resident in comparison with the simple drawings and even angiographic views from different angles without the need for computers and similar equipment. The disadvantages include the psychological resistance of residents to the use of something in surgical training that usually is considered to be a toy, and not being as clean as drawings or computerized images. Although technology and computerized software using the patients' own imaging data seems likely to become more advanced in the future, use of play dough in some complicated cerebral aneurysm cases may be helpful in 3D reconstruction of the real situation.

  6. 48 CFR 227.7203-13 - Government right to review, verify, challenge and validate asserted restrictions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227..., reproduce, release, or disclose computer software or computer software documentation do not, by themselves, determine the extent of the Government's rights in such software or documentation. The Government may...

  7. 48 CFR 227.7203-13 - Government right to review, verify, challenge and validate asserted restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227..., reproduce, release, or disclose computer software or computer software documentation do not, by themselves, determine the extent of the Government's rights in such software or documentation. The Government may...

  8. 48 CFR 227.7203-13 - Government right to review, verify, challenge and validate asserted restrictions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227..., reproduce, release, or disclose computer software or computer software documentation do not, by themselves, determine the extent of the Government's rights in such software or documentation. The Government may...

  9. 48 CFR 227.7203-13 - Government right to review, verify, challenge and validate asserted restrictions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227..., reproduce, release, or disclose computer software or computer software documentation do not, by themselves, determine the extent of the Government's rights in such software or documentation. The Government may...

  10. 48 CFR 227.7203-13 - Government right to review, verify, challenge and validate asserted restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227..., reproduce, release, or disclose computer software or computer software documentation do not, by themselves, determine the extent of the Government's rights in such software or documentation. The Government may...

  11. Reliability of a smartphone-based goniometer for knee joint goniometry.

    PubMed

    Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero

    2013-06-01

    The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

  12. Intrinsic, Transitional, and Extrinsic Morphological Factors Associated With Rupture of Intracranial Aneurysms.

    PubMed

    Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose

    2015-09-01

    As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.

  13. Computer software.

    PubMed

    Rosenthal, L E

    1986-10-01

    Software is the component in a computer system that permits the hardware to perform the various functions that a computer system is capable of doing. The history of software and its development can be traced to the early nineteenth century. All computer systems are designed to utilize the "stored program concept" as first developed by Charles Babbage in the 1850s. The concept was lost until the mid-1940s, when modern computers made their appearance. Today, because of the complex and myriad tasks that a computer system can perform, there has been a differentiation of types of software. There is software designed to perform specific business applications. There is software that controls the overall operation of a computer system. And there is software that is designed to carry out specialized tasks. Regardless of types, software is the most critical component of any computer system. Without it, all one has is a collection of circuits, transistors, and silicone chips.

  14. 48 CFR 227.7202-1 - Policy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-1 Policy. (a) Commercial computer software or commercial computer software documentation shall be acquired under the licenses customarily provided to the public...

  15. 48 CFR 227.7202-1 - Policy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-1 Policy. (a) Commercial computer software or commercial computer software documentation shall be acquired under the licenses customarily provided to the public...

  16. 48 CFR 227.7202-1 - Policy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-1 Policy. (a) Commercial computer software or commercial computer software documentation shall be acquired under the licenses customarily provided to the public...

  17. 48 CFR 227.7202-1 - Policy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-1 Policy. (a) Commercial computer software or commercial computer software documentation shall be acquired under the licenses customarily provided to the public...

  18. 48 CFR 227.7202-1 - Policy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7202-1 Policy. (a) Commercial computer software or commercial computer software documentation shall be acquired under the licenses customarily provided to the public...

  19. 77 FR 50726 - Software Requirement Specifications for Digital Computer Software and Complex Electronics Used in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... Computer Software and Complex Electronics Used in Safety Systems of Nuclear Power Plants AGENCY: Nuclear...-1209, ``Software Requirement Specifications for Digital Computer Software and Complex Electronics used... Electronics Engineers (ANSI/IEEE) Standard 830-1998, ``IEEE Recommended Practice for Software Requirements...

  20. Modular preoperative planning software for computer-aided oral implantology and the application of a novel stereolithographic template: a pilot study.

    PubMed

    Chen, Xiaojun; Yuan, Jianbing; Wang, Chengtao; Huang, Yuanliang; Kang, Lu

    2010-09-01

    In the field of oral implantology, there is a trend toward computer-aided implant surgery, especially the application of computerized tomography (CT)-derived surgical templates. However, because of relatively unsatisfactory match between the templates and receptor sites, conventional surgical templates may not be accurate enough for the severely resorbed edentulous cases during the procedure of transferring the preoperative plan to the actual surgery. The purpose of this study is to introduce a novel bone-tooth-combined-supported surgical guide, which is designed by utilizing a special modular software and fabricated via stereolithography technique using both laser scanning and CT imaging, thus improving the fit accuracy and reliability. A modular preoperative planning software was developed for computer-aided oral implantology. With the introduction of dynamic link libraries and some well-known free, open-source software libraries such as Visualization Toolkit (Kitware, Inc., New York, USA) and Insight Toolkit (Kitware, Inc.) a plug-in evolutive software architecture was established, allowing for expandability, accessibility, and maintainability in our system. To provide a link between the preoperative plan and the actual surgery, a novel bone-tooth-combined-supported surgical template was fabricated, utilizing laser scanning, image registration, and rapid prototyping. Clinical studies were conducted on four partially edentulous cases to make a comparison with the conventional bone-supported templates. The fixation was more stable than tooth-supported templates because laser scanning technology obtained detailed dentition information, which brought about the unique topography between the match surface of the templates and the adjacent teeth. The average distance deviations at the coronal and apical point of the implant were 0.66 mm (range: 0.3-1.2) and 0.86 mm (range: 0.4-1.2), and the average angle deviation was 1.84 degrees (range: 0.6-2.8 degrees ). This pilot study proves that the novel combined-supported templates are superior to the conventional ones. However, more clinical cases will be conducted to demonstrate their feasibility and reliability.

  1. 48 CFR 227.7207 - Contractor data repositories.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Computer Software and Computer Software Documentation 227.7207 Contractor data repositories. Follow 227.7108 when it is in the Government's interests to have a data repository include computer software or to have a separate computer software repository. Contractual instruments establishing the repository...

  2. 48 CFR 227.7200 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7200 Scope of subpart. This subpart— (a) Prescribes policies and procedures for the acquisition of computer software and computer software documentation, and the...

  3. 48 CFR 227.7200 - Scope of subpart.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7200 Scope of subpart. This subpart— (a) Prescribes policies and procedures for the acquisition of computer software and computer software documentation, and the...

  4. 48 CFR 227.7200 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7200 Scope of subpart. This subpart— (a) Prescribes policies and procedures for the acquisition of computer software and computer software documentation, and the...

  5. 48 CFR 227.7207 - Contractor data repositories.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Computer Software and Computer Software Documentation 227.7207 Contractor data repositories. Follow 227.7108 when it is in the Government's interests to have a data repository include computer software or to have a separate computer software repository. Contractual instruments establishing the repository...

  6. 48 CFR 227.7207 - Contractor data repositories.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Computer Software and Computer Software Documentation 227.7207 Contractor data repositories. Follow 227.7108 when it is in the Government's interests to have a data repository include computer software or to have a separate computer software repository. Contractual instruments establishing the repository...

  7. 48 CFR 227.7200 - Scope of subpart.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7200 Scope of subpart. This subpart— (a) Prescribes policies and procedures for the acquisition of computer software and computer software documentation, and the...

  8. 48 CFR 227.7207 - Contractor data repositories.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Computer Software and Computer Software Documentation 227.7207 Contractor data repositories. Follow 227.7108 when it is in the Government's interests to have a data repository include computer software or to have a separate computer software repository. Contractual instruments establishing the repository...

  9. 48 CFR 227.7200 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7200 Scope of subpart. This subpart— (a) Prescribes policies and procedures for the acquisition of computer software and computer software documentation, and the...

  10. User Interface Developed for Controls/CFD Interdisciplinary Research

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The NASA Lewis Research Center, in conjunction with the University of Akron, is developing analytical methods and software tools to create a cross-discipline "bridge" between controls and computational fluid dynamics (CFD) technologies. Traditionally, the controls analyst has used simulations based on large lumping techniques to generate low-order linear models convenient for designing propulsion system controls. For complex, high-speed vehicles such as the High Speed Civil Transport (HSCT), simulations based on CFD methods are required to capture the relevant flow physics. The use of CFD should also help reduce the development time and costs associated with experimentally tuning the control system. The initial application for this research is the High Speed Civil Transport inlet control problem. A major aspect of this research is the development of a controls/CFD interface for non-CFD experts, to facilitate the interactive operation of CFD simulations and the extraction of reduced-order, time-accurate models from CFD results. A distributed computing approach for implementing the interface is being explored. Software being developed as part of the Integrated CFD and Experiments (ICE) project provides the basis for the operating environment, including run-time displays and information (data base) management. Message-passing software is used to communicate between the ICE system and the CFD simulation, which can reside on distributed, parallel computing systems. Initially, the one-dimensional Large-Perturbation Inlet (LAPIN) code is being used to simulate a High Speed Civil Transport type inlet. LAPIN can model real supersonic inlet features, including bleeds, bypasses, and variable geometry, such as translating or variable-ramp-angle centerbodies. Work is in progress to use parallel versions of the multidimensional NPARC code.

  11. Virtual tool mark generation for efficient striation analysis in forensic science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekstrand, Laura

    In 2009, a National Academy of Sciences report called for investigation into the scienti c basis behind tool mark comparisons (National Academy of Sciences, 2009). Answering this call, Chumbley et al. (2010) attempted to prove or disprove the hypothesis that tool marks are unique to a single tool. They developed a statistical algorithm that could, in most cases, discern matching and non-matching tool marks made at di erent angles by sequentially numbered screwdriver tips. Moreover, in the cases where the algorithm misinterpreted a pair of marks, an experienced forensics examiner could discern the correct outcome. While this research served tomore » con rm the basic assumptions behind tool mark analysis, it also suggested that statistical analysis software could help to reduce the examiner's workload. This led to a new tool mark analysis approach, introduced in this thesis, that relies on 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. These scans are carefully cleaned to remove noise from the data acquisition process and assigned a coordinate system that mathematically de nes angles and twists in a natural way. The marking process is then simulated by using a 3D graphics software package to impart rotations to the tip and take the projection of the tip's geometry in the direction of tool travel. The edge of this projection, retrieved from the 3D graphics software, becomes a virtual tool mark. Using this method, virtual marks are made at increments of 5 and compared to a scan of the evidence mark. The previously developed statistical package from Chumbley et al. (2010) performs the comparison, comparing the similarity of the geometry of both marks to the similarity that would occur due to random chance. The resulting statistical measure of the likelihood of the match informs the examiner of the angle of the best matching virtual mark, allowing the examiner to focus his/her mark analysis on a smaller range of angles. Preliminary results are quite promising. In a study with both sides of 6 screwdriver tips and 34 corresponding marks, the method distinguished known matches from known non-matches with zero false positive matches and only two matches mistaken for non-matches. For matches, it could predict the correct marking angle within 5-10 . Moreover, on a standard desktop computer, the virtual marking software is capable of cleaning 3D tip and plate scans in minutes and producing a virtual mark and comparing it to a real mark in seconds. These results support several of the professional conclusions of the tool mark analysis com- munity, including the idea that marks produced by the same tool only match if they are made at similar angles. The method also displays the potential to automate part of the comparison process, freeing the examiner to focus on other tasks, which is important in busy, backlogged crime labs. Finally, the method o ers the unique chance to directly link an evidence mark to the tool that produced it while reducing potential damage to the evidence.« less

  12. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  13. 48 CFR 212.212 - Computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Computer software. 212.212... Acquisition of Commercial Items 212.212 Computer software. (1) Departments and agencies shall identify and... technology development), opportunities for the use of commercial computer software and other non...

  14. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  15. 48 CFR 212.212 - Computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Computer software. 212.212... Acquisition of Commercial Items 212.212 Computer software. (1) Departments and agencies shall identify and... technology development), opportunities for the use of commercial computer software and other non...

  16. 48 CFR 212.212 - Computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Computer software. 212.212... Acquisition of Commercial Items 212.212 Computer software. (1) Departments and agencies shall identify and... technology development), opportunities for the use of commercial computer software and other non...

  17. 48 CFR 212.212 - Computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Computer software. 212.212... Acquisition of Commercial Items 212.212 Computer software. (1) Departments and agencies shall identify and... technology development), opportunities for the use of commercial computer software and other non...

  18. 48 CFR 212.212 - Computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Computer software. 212.212... Acquisition of Commercial Items 212.212 Computer software. (1) Departments and agencies shall identify and... technology development), opportunities for the use of commercial computer software and other non...

  19. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  20. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  1. 48 CFR 227.7203-11 - Contractor procedures and records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Rights in Computer Software and Computer Software Documentation 227.7203-11 Contractor procedures and records. (a) The clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation, requires a contractor, and its subcontractors or suppliers that will...

  2. Field Test of Route Planning Software for Lunar Polar Missions

    NASA Astrophysics Data System (ADS)

    Horchler, A. D.; Cunningham, C.; Jones, H. L.; Arnett, D.; Fang, E.; Amoroso, E.; Otten, N.; Kitchell, F.; Holst, I.; Rock, G.; Whittaker, W.

    2017-10-01

    A novel field test paradigm has been developed to demonstrate and validate route planning software in the stark low-angled light and sweeping shadows a rover would experience at the poles of the Moon. Software, ConOps, and test results are presented.

  3. Exoskeleton for gait rehabilitation of children: Conceptual design.

    PubMed

    Cornejo, Jorge L; Santana, Jesus F; Salinas, Sergio A

    2017-07-01

    This paper presents the conceptual design of an exoskeleton for gait rehabilitation of children. This system has electronics, mechanicals and software sections, which are implemented and tested using a mannequin of a child. The prototype uses servomotors to move robotic joints that are attached to simulated patient's legs. The design has 4 DOF (degrees of freedom) two for hip joints and other two for knee joints, in the sagittal plane. A microcontroller measures sensor signals, controls motors and exchanges data with a computer. The user interacts with a graphical interface to configure, control and monitor the exoskeleton activities. The laboratory tests show soften movements in joint angle tracking.

  4. Three-dimensional scanner based on fringe projection

    NASA Astrophysics Data System (ADS)

    Nouri, Taoufik

    1995-07-01

    This article presents a way of scanning 3D objects using noninvasive and contact loss techniques. The principle is to project parallel fringes on an object and then to record the object at two viewing angles. With an appropriate treatment one can reconstruct the 3D object even when it has no symmetry planes. The 3D surface data are available immediately in digital form for computer visualization and for analysis software tools. The optical setup for recording the object, the data extraction and treatment, and the reconstruction of the object are reported and commented on. Application is proposed for reconstructive/cosmetic surgery, CAD, animation, and research.

  5. Unconstrained paving and plastering method for generating finite element meshes

    DOEpatents

    Staten, Matthew L.; Owen, Steven J.; Blacker, Teddy D.; Kerr, Robert

    2010-03-02

    Computer software for and a method of generating a conformal all quadrilateral or hexahedral mesh comprising selecting an object with unmeshed boundaries and performing the following while unmeshed voids are larger than twice a desired element size and unrecognizable as either a midpoint subdividable or pave-and-sweepable polyhedra: selecting a front to advance; based on sizes of fronts and angles with adjacent fronts, determining which adjacent fronts should be advanced with the selected front; advancing the fronts; detecting proximities with other nearby fronts; resolving any found proximities; forming quadrilaterals or unconstrained columns of hexahedra where two layers cross; and establishing hexahedral elements where three layers cross.

  6. Virtual Reality Modelling Simulation of the Re-entry Motion of an Axialsymmetric Vehicle

    NASA Astrophysics Data System (ADS)

    Guidi, A.; Chu, Q.. P.; Mulder, J. A.

    This work started during the stability analysis of the Delft Aerospace Re-entry Test demonstrator (DART) which is a small axisymmetric ballistic re-entry vehicle. The dynamic stability evaluation of an axisymmetric re-entry vehicle is especially concerned on the behaviour of its angle of attack during the flight through the atmosphere. The variation in the angle of attack is essential for prediction of the trajectory of the vehicle and for heating requirement of the structure of the vehicle. The concept of the total angle of attack and the windward meridian plane are introduced. The position of the centre of pressure can be a crucial point in the stability of the vehicle. Although the simpleness of an axisymmetric shape, the re-entry of such a vehicle is characterised by several complex phenomenologies that were analysed with the aid of the flight simulator and of a 3D virtual reality modeling simulator. Simulations were performed with a 25° AOA initial condition in order to simulate the response of the vehicle to a disturbance that may occur during the flight causing a variation in attitude from its Trim . Certain aspects of re-entry vehicle motion are conveniently described in the terms of Euler angles. Using the Eulerian angle it is possible to generate a tridimensional animation of the output of the Flight Simulator. This tridimensional analysis is of great importance in order to understand the mentioned complex motions. Furthermore with growing in computer power it is possible to generate online visualisation of the simulations. The output of the flight simulator was used in a software written in Virtual Reality Modelling Language (VRML). With VRML this software was possible the visualisation of the re-entry motion of the vehicle. With this option the animation can run on-line during the with the flight simulator and can be also easily published on the internet or send to other users in very small file size. (the VRLM simulation of the re-entry, can be seen at the official DART internet site: www.dart-project.com)

  7. 48 CFR 212.7003 - Technical data and computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... computer software. 212.7003 Section 212.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION... data and computer software. For purposes of establishing delivery requirements and license rights for technical data under 227.7102 and for computer software under 227.7202, there shall be a rebuttable...

  8. 48 CFR 212.7003 - Technical data and computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... computer software. 212.7003 Section 212.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION... data and computer software. For purposes of establishing delivery requirements and license rights for technical data under 227.7102 and for computer software under 227.7202, there shall be a rebuttable...

  9. 48 CFR 212.7003 - Technical data and computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... computer software. 212.7003 Section 212.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION... data and computer software. For purposes of establishing delivery requirements and license rights for technical data under 227.7102 and for computer software under 227.7202, there shall be a rebuttable...

  10. 48 CFR 212.7003 - Technical data and computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... computer software. 212.7003 Section 212.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION... data and computer software. For purposes of establishing delivery requirements and license rights for technical data under 227.7102 and for computer software under 227.7202, there shall be a rebuttable...

  11. 48 CFR 212.7003 - Technical data and computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computer software. 212.7003 Section 212.7003 Federal Acquisition Regulations System DEFENSE ACQUISITION... data and computer software. For purposes of establishing delivery requirements and license rights for technical data under 227.7102 and for computer software under 227.7202, there shall be a rebuttable...

  12. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  13. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  14. 48 CFR 227.7203-4 - License rights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software and Computer Software Documentation 227.7203-4 License rights. (a) Grant of license. The Government obtains rights in computer software or computer software documentation, including a copyright license, under an irrevocable license granted or obtained by the contractor which developed the software...

  15. 48 CFR 227.7203-4 - License rights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software and Computer Software Documentation 227.7203-4 License rights. (a) Grant of license. The Government obtains rights in computer software or computer software documentation, including a copyright license, under an irrevocable license granted or obtained by the contractor which developed the software...

  16. 48 CFR 227.7203-4 - License rights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software and Computer Software Documentation 227.7203-4 License rights. (a) Grant of license. The Government obtains rights in computer software or computer software documentation, including a copyright license, under an irrevocable license granted or obtained by the contractor which developed the software...

  17. 48 CFR 227.7203-4 - License rights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software and Computer Software Documentation 227.7203-4 License rights. (a) Grant of license. The Government obtains rights in computer software or computer software documentation, including a copyright license, under an irrevocable license granted or obtained by the contractor which developed the software...

  18. 48 CFR 227.7203-4 - License rights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software and Computer Software Documentation 227.7203-4 License rights. (a) Grant of license. The Government obtains rights in computer software or computer software documentation, including a copyright license, under an irrevocable license granted or obtained by the contractor which developed the software...

  19. Reliability and scientific use of a surgical planning software for anterior cervical discectomy and fusion (ACDF).

    PubMed

    Barth, Martin; Weiß, Christel; Brenke, Christopher; Schmieder, Kirsten

    2017-04-01

    Software-based planning of a spinal implant inheres in the promise of precision and superior results. The purpose of the study was to analyze the measurement reliability, prognostic value, and scientific use of a surgical planning software in patients receiving anterior cervical discectomy and fusion (ACDF). Lateral neutral, flexion, and extension radiographs of patients receiving tailored cages as suggested by the planning software were available for analysis. Differences of vertebral wedging angles and segmental height of all cervical segments were determined at different timepoints using intraclass correlation coefficients (ICC). Cervical lordosis (C2/C7), segmental heights, global, and segmental range of motion (ROM) were determined at different timepoints. Clinical and radiological variables were correlated 12 months after surgery. 282 radiographs of 35 patients with a mean age of 53.1 ± 12.0 years were analyzed. Measurement of segmental height was highly accurate with an ICC near to 1, but angle measurements showed low ICC values. Likewise, the ICCs of the prognosticated values were low. Postoperatively, there was a significant decrease of segmental height (p < 0.0001) and loss of C2/C7 ROM (p = 0.036). ROM of unfused segments also significantly decreased (p = 0.016). High NDI was associated with low subsidence rates. The surgical planning software showed high accuracy in the measurement of height differences and lower accuracy values with angle measurements. Both the prognosticated height and angle values were arbitrary. Global ROM, ROM of the fused and intact segments, is restricted after ACDF.

  20. Balloon Design Software

    NASA Technical Reports Server (NTRS)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  1. SwarmSight: Real-time Tracking of Insect Antenna Movements and Proboscis Extension Reflex Using a Common Preparation and Conventional Hardware

    PubMed Central

    Birgiolas, Justas; Jernigan, Christopher M.; Gerkin, Richard C.; Smith, Brian H.; Crook, Sharon M.

    2017-01-01

    Many scientifically and agriculturally important insects use antennae to detect the presence of volatile chemical compounds and extend their proboscis during feeding. The ability to rapidly obtain high-resolution measurements of natural antenna and proboscis movements and assess how they change in response to chemical, developmental, and genetic manipulations can aid the understanding of insect behavior. By extending our previous work on assessing aggregate insect swarm or animal group movements from natural and laboratory videos using the video analysis software SwarmSight, we developed a novel, free, and open-source software module, SwarmSight Appendage Tracking (SwarmSight.org) for frame-by-frame tracking of insect antenna and proboscis positions from conventional web camera videos using conventional computers. The software processes frames about 120 times faster than humans, performs at better than human accuracy, and, using 30 frames per second (fps) videos, can capture antennal dynamics up to 15 Hz. The software was used to track the antennal response of honey bees to two odors and found significant mean antennal retractions away from the odor source about 1 s after odor presentation. We observed antenna position density heat map cluster formation and cluster and mean angle dependence on odor concentration. PMID:29364251

  2. MOLSIM: A modular molecular simulation software

    PubMed Central

    Jurij, Reščič

    2015-01-01

    The modular software MOLSIM for all‐atom molecular and coarse‐grained simulations is presented with focus on the underlying concepts used. The software possesses four unique features: (1) it is an integrated software for molecular dynamic, Monte Carlo, and Brownian dynamics simulations; (2) simulated objects are constructed in a hierarchical fashion representing atoms, rigid molecules and colloids, flexible chains, hierarchical polymers, and cross‐linked networks; (3) long‐range interactions involving charges, dipoles and/or anisotropic dipole polarizabilities are handled either with the standard Ewald sum, the smooth particle mesh Ewald sum, or the reaction‐field technique; (4) statistical uncertainties are provided for all calculated observables. In addition, MOLSIM supports various statistical ensembles, and several types of simulation cells and boundary conditions are available. Intermolecular interactions comprise tabulated pairwise potentials for speed and uniformity and many‐body interactions involve anisotropic polarizabilities. Intramolecular interactions include bond, angle, and crosslink potentials. A very large set of analyses of static and dynamic properties is provided. The capability of MOLSIM can be extended by user‐providing routines controlling, for example, start conditions, intermolecular potentials, and analyses. An extensive set of case studies in the field of soft matter is presented covering colloids, polymers, and crosslinked networks. © 2015 The Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc. PMID:25994597

  3. 5m RPV for Exploring Joined Wing Gust Response

    DTIC Science & Technology

    2009-12-01

    an outer layer of light glass scrim used as the first layer. Varying layers of carbon cloth are used and then the core material is added. In this...for various angles of attack and sideslip angles. A parametric model is developed using Phoenix Integration’s Model Center Software (MC). This model...by the ground control software and finally a piece of real-time footage taken from the on-board, gimbaled camera. 2009 Progress Report 27

  4. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    PubMed

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. 48 CFR 227.7203-12 - Government right to establish conformity of markings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-12... identified in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. All other markings are nonconforming markings. An authorized marking that...

  6. 48 CFR 227.7203-12 - Government right to establish conformity of markings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-12... identified in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. All other markings are nonconforming markings. An authorized marking that...

  7. 48 CFR 227.7203-12 - Government right to establish conformity of markings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-12... identified in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. All other markings are nonconforming markings. An authorized marking that...

  8. 48 CFR 227.7203-12 - Government right to establish conformity of markings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-12... identified in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. All other markings are nonconforming markings. An authorized marking that...

  9. 48 CFR 227.7203-12 - Government right to establish conformity of markings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7203-12... identified in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. All other markings are nonconforming markings. An authorized marking that...

  10. Alteration of maxillary and mandibular growth of adult patients with unoperated isolated cleft palate.

    PubMed

    Yang, Yunqiang; Wu, Yeke; Gu, Yifei; Yang, Qijian; Shi, Bing; Zheng, Qian; Wang, Yan

    2013-07-01

    The objective of this study was to investigate the effects of cleft palate itself on the growth of maxilla and mandible. Fifty-two adult female patients with unoperated isolated cleft palate and 52 adult female individuals with normal occlusion were included in our study. Computer software was used for lateral cephalometry measurement. Manual measurement was performed for dental cast measurements, and sample t test analysis was applied to analyze the differences between the 2 groups using SPSS 17.0. The sella-nasion-subspinale point angle, subspinale-nasion-supramentale point angle, and maxillary arch length of the cleft group were significantly smaller than those of the control group (P < 0.01). Both maxillary and mandibular posterior dental arch widths of the cleft group were significantly larger compared with the control group (P < 0.01), whereas the sella-nasion-supramentale point angle, mandible arch length, palate height, and palate shelf inclination did not differ between the 2 groups. The measurements did not differ between the submucosal cleft and the overt cleft patients. Cleft palate itself has adverse effects on the maxilla growth with shorter maxillary arch length and wider posterior dental arch width.

  11. Exploring the Process of Adult Computer Software Training Using Andragogy, Situated Cognition, and a Minimalist Approach

    ERIC Educational Resources Information Center

    Hurt, Andrew C.

    2007-01-01

    With technology advances, computer software becomes increasingly difficult to learn. Adults often rely on software training to keep abreast of these changes. Instructor-led software training is frequently used to teach adults new software skills; however there is limited research regarding the best practices in adult computer software training.…

  12. 48 CFR 252.227-7032 - Rights in technical data and computer software (foreign).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and computer software (foreign). 252.227-7032 Section 252.227-7032 Federal Acquisition Regulations... computer software (foreign). As prescribed in 227.7103-17, use the following clause: Rights in Technical Data and Computer Software (Foreign) (JUN 1975) The United States Government may duplicate, use, and...

  13. 48 CFR 252.227-7032 - Rights in technical data and computer software (foreign).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and computer software (foreign). 252.227-7032 Section 252.227-7032 Federal Acquisition Regulations... computer software (foreign). As prescribed in 227.7103-17, use the following clause: Rights in Technical Data and Computer Software (Foreign) (JUN 1975) The United States Government may duplicate, use, and...

  14. 75 FR 6185 - Information Collection Requirement; Defense Federal Acquisition Regulation Supplement; Rights in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-08

    ...; Defense Federal Acquisition Regulation Supplement; Rights in Technical Data and Computer Software (OMB... 227.72, Rights in Computer Software and Computer Software Documentation, and related provisions and... rights in technical data and computer software. DoD needs this information to implement 10 U.S.C. 2320...

  15. 14 CFR 415.123 - Computing systems and software.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Computing systems and software. 415.123... Launch Vehicle From a Non-Federal Launch Site § 415.123 Computing systems and software. (a) An applicant's safety review document must describe all computing systems and software that perform a safety...

  16. 14 CFR 415.123 - Computing systems and software.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Computing systems and software. 415.123... Launch Vehicle From a Non-Federal Launch Site § 415.123 Computing systems and software. (a) An applicant's safety review document must describe all computing systems and software that perform a safety...

  17. 48 CFR 252.227-7032 - Rights in technical data and computer software (foreign).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and computer software (foreign). 252.227-7032 Section 252.227-7032 Federal Acquisition Regulations... computer software (foreign). As prescribed in 227.7103-17, use the following clause: Rights in Technical Data and Computer Software (Foreign) (JUN 1975) The United States Government may duplicate, use, and...

  18. 48 CFR 252.227-7032 - Rights in technical data and computer software (foreign).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and computer software (foreign). 252.227-7032 Section 252.227-7032 Federal Acquisition Regulations... computer software (foreign). As prescribed in 227.7103-17, use the following clause: Rights in Technical Data and Computer Software (Foreign) (JUN 1975) The United States Government may duplicate, use, and...

  19. 48 CFR 252.227-7032 - Rights in technical data and computer software (foreign).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and computer software (foreign). 252.227-7032 Section 252.227-7032 Federal Acquisition Regulations... computer software (foreign). As prescribed in 227.7103-17, use the following clause: Rights in Technical Data and Computer Software (Foreign) (JUN 1975) The United States Government may duplicate, use, and...

  20. 78 FR 30898 - Information Collection Requirement; Defense Federal Acquisition Regulation Supplement; Rights in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ... Data and Computer Software AGENCY: Defense Acquisition Regulations System; Department of Defense (DoD... in Technical Data, and Subpart 227.72, Rights in Computer Software and Computer Software... are associated with rights in technical data and computer software. DoD needs this information to...

  1. 14 CFR 415.123 - Computing systems and software.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Computing systems and software. 415.123... Launch Vehicle From a Non-Federal Launch Site § 415.123 Computing systems and software. (a) An applicant's safety review document must describe all computing systems and software that perform a safety...

  2. 14 CFR 415.123 - Computing systems and software.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Computing systems and software. 415.123... Launch Vehicle From a Non-Federal Launch Site § 415.123 Computing systems and software. (a) An applicant's safety review document must describe all computing systems and software that perform a safety...

  3. 14 CFR 415.123 - Computing systems and software.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Computing systems and software. 415.123... Launch Vehicle From a Non-Federal Launch Site § 415.123 Computing systems and software. (a) An applicant's safety review document must describe all computing systems and software that perform a safety...

  4. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  5. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  6. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  7. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... public domain computer software. (a) General. This section prescribes the procedures for submission of legal documents pertaining to computer shareware and the deposit of public domain computer software...

  8. BioXTAS RAW: improvements to a free open-source program for small-angle X-ray scattering data reduction and analysis.

    PubMed

    Hopkins, Jesse Bennett; Gillilan, Richard E; Skou, Soren

    2017-10-01

    BioXTAS RAW is a graphical-user-interface-based free open-source Python program for reduction and analysis of small-angle X-ray solution scattering (SAXS) data. The software is designed for biological SAXS data and enables creation and plotting of one-dimensional scattering profiles from two-dimensional detector images, standard data operations such as averaging and subtraction and analysis of radius of gyration and molecular weight, and advanced analysis such as calculation of inverse Fourier transforms and envelopes. It also allows easy processing of inline size-exclusion chromatography coupled SAXS data and data deconvolution using the evolving factor analysis method. It provides an alternative to closed-source programs such as Primus and ScÅtter for primary data analysis. Because it can calibrate, mask and integrate images it also provides an alternative to synchrotron beamline pipelines that scientists can install on their own computers and use both at home and at the beamline.

  9. 78 FR 47804 - Verification, Validation, Reviews, and Audits for Digital Computer Software Used in Safety...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ..., ``Configuration Management Plans for Digital Computer Software used in Safety Systems of Nuclear Power Plants... Digital Computer Software Used in Safety Systems of Nuclear Power Plants AGENCY: Nuclear Regulatory..., Reviews, and Audits for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This...

  10. 48 CFR 27.404-2 - Limited rights data and restricted computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... restricted computer software. 27.404-2 Section 27.404-2 Federal Acquisition Regulations System FEDERAL... Copyrights 27.404-2 Limited rights data and restricted computer software. (a) General. The basic clause at 52... restricted computer software by withholding the data from the Government and instead delivering form, fit...

  11. 48 CFR 252.227-7026 - Deferred delivery of technical data or computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technical data or computer software. 252.227-7026 Section 252.227-7026 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(a), use the following clause: Deferred Delivery of Technical Data or Computer Software (APR 1988) The Government shall have the right to require, at...

  12. 48 CFR 27.404-2 - Limited rights data and restricted computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... restricted computer software. 27.404-2 Section 27.404-2 Federal Acquisition Regulations System FEDERAL... Copyrights 27.404-2 Limited rights data and restricted computer software. (a) General. The basic clause at 52... restricted computer software by withholding the data from the Government and instead delivering form, fit...

  13. 48 CFR 52.227-15 - Representation of Limited Rights Data and Restricted Computer Software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Rights Data and Restricted Computer Software. 52.227-15 Section 52.227-15 Federal Acquisition Regulations... Computer Software. As prescribed in 27.409(c), insert the following provision: Representation of Limited Rights Data and Restricted Computer Software (DEC 2007) (a) This solicitation sets forth the Government's...

  14. 48 CFR 252.227-7025 - Limitations on the use or disclosure of government-furnished information marked with restrictive...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... contracts in which the Government will furnish the Contractor with computer software or computer software... rights” are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. (3) For Small Business Innovation Research program contracts, the...

  15. 48 CFR 27.404-2 - Limited rights data and restricted computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... restricted computer software. 27.404-2 Section 27.404-2 Federal Acquisition Regulations System FEDERAL... Copyrights 27.404-2 Limited rights data and restricted computer software. (a) General. The basic clause at 52... restricted computer software by withholding the data from the Government and instead delivering form, fit...

  16. 48 CFR 52.227-15 - Representation of Limited Rights Data and Restricted Computer Software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Rights Data and Restricted Computer Software. 52.227-15 Section 52.227-15 Federal Acquisition Regulations... Computer Software. As prescribed in 27.409(c), insert the following provision: Representation of Limited Rights Data and Restricted Computer Software (DEC 2007) (a) This solicitation sets forth the Government's...

  17. 48 CFR 252.227-7019 - Validation of asserted restrictions-Computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... restrictions-Computer software. 252.227-7019 Section 252.227-7019 Federal Acquisition Regulations System...—Computer software. As prescribed in 227.7104(e)(3) or 227.7203-6(c), use the following clause: Validation of Asserted Restrictions—Computer Software (JUN 1995) (a) Definitions. (1) As used in this clause...

  18. 48 CFR 52.227-15 - Representation of Limited Rights Data and Restricted Computer Software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Rights Data and Restricted Computer Software. 52.227-15 Section 52.227-15 Federal Acquisition Regulations... Computer Software. As prescribed in 27.409(c), insert the following provision: Representation of Limited Rights Data and Restricted Computer Software (DEC 2007) (a) This solicitation sets forth the Government's...

  19. 48 CFR 252.227-7019 - Validation of asserted restrictions-Computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... restrictions-Computer software. 252.227-7019 Section 252.227-7019 Federal Acquisition Regulations System...—Computer software. As prescribed in 227.7104(e)(3) or 227.7203-6(c), use the following clause: Validation of Asserted Restrictions—Computer Software (SEP 2011) (a) Definitions. (1) As used in this clause...

  20. 48 CFR 252.227-7026 - Deferred delivery of technical data or computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... technical data or computer software. 252.227-7026 Section 252.227-7026 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(a), use the following clause: Deferred Delivery of Technical Data or Computer Software (APR 1988) The Government shall have the right to require, at...

  1. 48 CFR 252.227-7025 - Limitations on the Use or Disclosure of Government-Furnished Information Marked with Restrictive...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... contracts in which the Government will furnish the Contractor with computer software or computer software... rights” are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. (3) For Small Business Innovation Research program contracts, the...

  2. 48 CFR 252.227-7019 - Validation of asserted restrictions-Computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... restrictions-Computer software. 252.227-7019 Section 252.227-7019 Federal Acquisition Regulations System...—Computer software. As prescribed in 227.7104(e)(3) or 227.7203-6(c), use the following clause: Validation of Asserted Restrictions—Computer Software (SEP 2011) (a) Definitions. (1) As used in this clause...

  3. 48 CFR 52.227-15 - Representation of Limited Rights Data and Restricted Computer Software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Rights Data and Restricted Computer Software. 52.227-15 Section 52.227-15 Federal Acquisition Regulations... Computer Software. As prescribed in 27.409(c), insert the following provision: Representation of Limited Rights Data and Restricted Computer Software (DEC 2007) (a) This solicitation sets forth the Government's...

  4. 48 CFR 27.404-2 - Limited rights data and restricted computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... restricted computer software. 27.404-2 Section 27.404-2 Federal Acquisition Regulations System FEDERAL... Copyrights 27.404-2 Limited rights data and restricted computer software. (a) General. The basic clause at 52... restricted computer software by withholding the data from the Government and instead delivering form, fit...

  5. 48 CFR 52.227-15 - Representation of Limited Rights Data and Restricted Computer Software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Rights Data and Restricted Computer Software. 52.227-15 Section 52.227-15 Federal Acquisition Regulations... Computer Software. As prescribed in 27.409(c), insert the following provision: Representation of Limited Rights Data and Restricted Computer Software (DEC 2007) (a) This solicitation sets forth the Government's...

  6. 48 CFR 252.227-7026 - Deferred delivery of technical data or computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... technical data or computer software. 252.227-7026 Section 252.227-7026 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(a), use the following clause: Deferred Delivery of Technical Data or Computer Software (APR 1988) The Government shall have the right to require, at...

  7. 48 CFR 252.227-7025 - Limitations on the use or disclosure of government-furnished information marked with restrictive...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... contracts in which the Government will furnish the Contractor with computer software or computer software... rights” are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. (3) For Small Business Innovation Research program contracts, the...

  8. 48 CFR 252.227-7019 - Validation of asserted restrictions-Computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... restrictions-Computer software. 252.227-7019 Section 252.227-7019 Federal Acquisition Regulations System...—Computer software. As prescribed in 227.7104(e)(3) or 227.7203-6(c), use the following clause: Validation of Asserted Restrictions—Computer Software (SEP 2011) (a) Definitions. (1) As used in this clause...

  9. 48 CFR 252.227-7026 - Deferred delivery of technical data or computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... technical data or computer software. 252.227-7026 Section 252.227-7026 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(a), use the following clause: Deferred Delivery of Technical Data or Computer Software (APR 1988) The Government shall have the right to require, at...

  10. 48 CFR 252.227-7025 - Limitations on the Use or Disclosure of Government-Furnished Information Marked with Restrictive...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... contracts in which the Government will furnish the Contractor with computer software or computer software... rights” are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and Noncommercial Computer Software Documentation. (3) For Small Business Innovation Research program contracts, the...

  11. 48 CFR 252.227-7019 - Validation of asserted restrictions-Computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... restrictions-Computer software. 252.227-7019 Section 252.227-7019 Federal Acquisition Regulations System...—Computer software. As prescribed in 227.7104(e)(3) or 227.7203-6(c), use the following clause: Validation of Asserted Restrictions—Computer Software (SEP 2011) (a) Definitions. (1) As used in this clause...

  12. 48 CFR 252.227-7026 - Deferred delivery of technical data or computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... technical data or computer software. 252.227-7026 Section 252.227-7026 Federal Acquisition Regulations... data or computer software. As prescribed at 227.7103-8(a), use the following clause: Deferred Delivery of Technical Data or Computer Software (APR 1988) The Government shall have the right to require, at...

  13. 48 CFR 27.404-2 - Limited rights data and restricted computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... restricted computer software. 27.404-2 Section 27.404-2 Federal Acquisition Regulations System FEDERAL... Copyrights 27.404-2 Limited rights data and restricted computer software. (a) General. The basic clause at 52... restricted computer software by withholding the data from the Government and instead delivering form, fit...

  14. Geomagnetic main field modeling with DMSP

    NASA Astrophysics Data System (ADS)

    Alken, P.; Maus, S.; Lühr, H.; Redmon, R. J.; Rich, F.; Bowman, B.; O'Malley, S. M.

    2014-05-01

    The Defense Meteorological Satellite Program (DMSP) launches and maintains a network of satellites to monitor the meteorological, oceanographic, and solar-terrestrial physics environments. In the past decade, geomagnetic field modelers have focused much attention on magnetic measurements from missions such as CHAMP, Ørsted, and SAC-C. With the completion of the CHAMP mission in 2010, there has been a multiyear gap in satellite-based vector magnetic field measurements available for main field modeling. In this study, we calibrate the special sensor magnetometer instrument on board DMSP to create a data set suitable for main field modeling. These vector field measurements are calibrated to compute instrument timing shifts, scale factors, offsets, and nonorthogonality angles of the fluxgate magnetometer cores. Euler angles are then computed to determine the orientation of the vector magnetometer with respect to a local coordinate system. We fit a degree 15 main field model to the data set and compare with the World Magnetic Model and Ørsted scalar measurements. We call this model DMSP-MAG-1, and its coefficients and software are available for download at http://geomag.org/models/dmsp.html. Our results indicate that the DMSP data set will be a valuable source for main field modeling for the years between CHAMP and the recently launched Swarm mission.

  15. Angular selective window systems: Assessment of technical potential for energy savings

    DOE PAGES

    Fernandes, Luis L.; Lee, Eleanor S.; McNeil, Andrew; ...

    2014-10-16

    Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAEmore » 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.« less

  16. The development of mathematics courseware for learning line and angle

    NASA Astrophysics Data System (ADS)

    Halim, Noor Dayana Abd; Han, Ong Boon; Abdullah, Zaleha; Yusup, Junaidah

    2015-05-01

    Learning software is a teaching aid which is often used in schools to increase students' motivation, attract students' attention and also improve the quality of teaching and learning process. However, the development of learning software should be followed the phases in Instructional Design (ID) Model, therefore the process can be carried out systematic and orderly. Thus, this concept paper describes the application of ADDIE model in the development of mathematics learning courseware for learning Line and Angle named CBL-Math. ADDIE model consists of five consecutive phases which are Analysis, Design, Development, Implementation and Evaluation. Each phase must be properly planned in order to achieve the objectives stated. Other than to describe the processes occurring in each phase, this paper also demonstrating how cognitive theory of multimedia learning principles are integrated in the developed courseware. The principles that applied in the courseware reduce the students' cognitive load while learning the topic of line and angle. With well prepared development process and the integration of appropriate principles, it is expected that the developed software can help students learn effectively and also increase students' achievement in the topic of Line and Angle.

  17. Computer-based test-bed for clinical assessment of hand/wrist feed-forward neuroprosthetic controllers using artificial neural networks.

    PubMed

    Luján, J L; Crago, P E

    2004-11-01

    Neuroprosthestic systems can be used to restore hand grasp and wrist control in individuals with C5/C6 spinal cord injury. A computer-based system was developed for the implementation, tuning and clinical assessment of neuroprosthetic controllers, using off-the-shelf hardware and software. The computer system turned a Pentium III PC running Windows NT into a non-dedicated, real-time system for the control of neuroprostheses. Software execution (written using the high-level programming languages LabVIEW and MATLAB) was divided into two phases: training and real-time control. During the training phase, the computer system collected input/output data by stimulating the muscles and measuring the muscle outputs in real-time, analysed the recorded data, generated a set of training data and trained an artificial neural network (ANN)-based controller. During real-time control, the computer system stimulated the muscles using stimulus pulsewidths predicted by the ANN controller in response to a sampled input from an external command source, to provide independent control of hand grasp and wrist posture. System timing was stable, reliable and capable of providing muscle stimulation at frequencies up to 24Hz. To demonstrate the application of the test-bed, an ANN-based controller was implemented with three inputs and two independent channels of stimulation. The ANN controller's ability to control hand grasp and wrist angle independently was assessed by quantitative comparison of the outputs of the stimulated muscles with a set of desired grasp or wrist postures determined by the command signal. Controller performance results were mixed, but the platform provided the tools to implement and assess future controller designs.

  18. The Regulation of Medical Computer Software as a “Device” under the Food, Drug, and Cosmetic Act

    PubMed Central

    Brannigan, Vincent

    1986-01-01

    Recent developments in computer software have raised the possibility that federal regulators may claim to control medical computer software as a “device” under the Food, Drug and Cosmetic Act. The purpose of this paper is to analyze the FDCA to determine whether computer software is included in the statutory scheme, examine constitutional arguments relating to computer software, and discuss regulatory principles that should be taken into account when deciding appropriate regulation. This paper is limited to computer program output used by humans in deciding appropriate medical therapy for a patient.

  19. Angular position of the cleat according to torsional parameters of the cyclist's lower limb.

    PubMed

    Ramos-Ortega, Javier; Domínguez, Gabriel; Castillo, José Manuel; Fernández-Seguín, Lourdes; Munuera, Pedro V

    2014-05-01

    The aim of this work was to study the relationship of torsional and rotational parameters of the lower limb with a specific angular position of the cleat to establish whether these variables affect the adjustment of the cleat. Correlational study. Motion analysis laboratory. Thirty-seven male cyclists of high performance. The variables studied of the cyclist's lower limb were hip rotation (internal and external), tibial torsion angle, Q angle, and forefoot adductus angle. The cleat angle was measured through a photograph of the sole and with an Rx of this using the software AutoCAD 2008. The variables were photograph angle (photograph), the variable denominated cleat-tarsus minor angle, and a variable denominated cleat-second metatarsal angle (Rx). Analysis included the intraclass correlation coefficient for the reliability of the measurements, Student's t test performed on the dependent variables to compare side, and the multiple linear regression models were calculated using the software SPSS 15.0 for Windows. The Student's t test performed on the dependent variables to compare side showed no significant differences (P = 0.209 for the photograph angle, P = 0.735 for the cleat-tarsus minor angle, and P = 0.801 for the cleat-second metatarsal angle). Values of R and R2 for the photograph angle model were 0.303 and 0.092 (P = 0.08), the cleat/tarsus minor angle model were 0.683 and 0.466 (P < 0.001), and the cleat/second metatarsal angle model were 0.618 and 0.382, respectively (P < 0.001). The equation given by the model was cleat-tarsus minor angle = 75.094 - (0.521 × forefoot adductus angle) + (0.116 × outward rotation of the hips) + (0.220 × Q angle).

  20. Does hemipelvis structure and position influence acetabulum orientation?

    PubMed

    Musielak, Bartosz; Jóźwiak, Marek; Rychlik, Michał; Chen, Brian Po-Jung; Idzior, Maciej; Grzegorzewski, Andrzej

    2016-03-16

    Although acetabulum orientation is well established anatomically and radiographically, its relation to the innominate bone has rarely been addressed. If explored, it could open the discussion on patomechanisms of such complex disorders as femoroacetabular impingement (FAI). We therefore evaluated the influence of pelvic bone position and structure on acetabular spatial orientation. We describe this relation and its clinical implications. This retrospective study was based on computed tomography scanning of three-dimensional models of 31 consecutive male pelvises (62 acetabulums). All measurements were based on CT spatial reconstruction with the use of highly specialized software (Rhinoceros). Relations between acetabular orientation (inclination, tilt, anteversion angles) and pelvic structure were evaluated. The following parameters were evaluated to assess the pelvic structure: iliac opening angle, iliac tilt angle, interspinous distance (ISD), intertuberous distance (ITD), height of the pelvis (HP), and the ISD/ITD/HP ratio. The linear and nonlinear dependence of the acetabular angles and hemipelvic measurements were examined with Pearson's product - moment correlation and Spearman's rank correlation coefficient. Correlations different from 0 with p < 0.05 were considered statistically significant. Comparison of the axis position with pelvis structure with orientation in the horizontal plane revealed a significant positive correlation between the acetabular anteversion angle and the iliac opening angle (p = 0.041 and 0.008, respectively). In the frontal plane, there was a positive correlation between the acetabular inclination angle and the iliac tilt angle (p = 0.025 and 0.014, respectively) and the acetabular inclination angle and the ISD/ITD/HP ratio (both p = 0.048). There is a significant correlation of the hemipelvic structure and acetabular orientation under anatomic conditions, especially in the frontal and horizontal planes. In the anteroposterior view, the more tilted-down innominate bone causes a more caudally oriented acetabulum axis, whereas in the horizontal view this relation is reversed. This study may serve as a basis for the discussion on the role of the pelvis in common disorders of the hip.

  1. Modeling photopolarimetric characteristics of comet dust as a polydisperse mixture of polyshaped rough spheroids

    NASA Astrophysics Data System (ADS)

    Kolokolova, L.; Das, H.; Dubovik, O.; Lapyonok, T.

    2013-12-01

    It is widely recognized now that the main component of comet dust is aggregated particles that consist of submicron grains. It is also well known that cometary dust obey a rather wide size distribution with abundant particles whose size reaches dozens of microns. However, numerous attempts of computer simulation of light scattering by comet dust using aggregated particles have not succeeded to consider particles larger than a couple of microns due to limitations in the memory and speed of available computers. Attempts to substitute aggregates by polydisperse solid particles (spheres, spheroids, cylinders) could not consistently reproduce observed angular and spectral characteristics of comet brightness and polarization even in such a general case as polyshaped (i.e. containing particles of a variety of aspect ratios) mixture of spheroids (Kolokolova et al., In: Photopolarimetry in Remote Sensing, Kluwer Acad. Publ., 431, 2004). In this study we are checking how well cometary dust can be modeled using modeling tools for rough spheroids. With this purpose we use the software package described in Dubovik et al. (J. Geophys. Res., 111, D11208, doi:10.1029/2005JD006619d, 2006) that allows for a substantial reduction of computer time in calculating scattering properties of spheroid mixtures by means of using pre-calculated kernels - quadrature coefficients employed in the numerical integration of spheroid optical properties over size and shape. The kernels were pre-calculated for spheroids of 25 axis ratios, ranging from 0.3 to 3, and 42 size bins within the size parameter range 0.01 - 625. This software package has been recently expanded with the possibility of simulating not only smooth but also rough spheroids that is used in present study. We consider refractive indexes of the materials typical for comet dust: silicate, carbon, organics, and their mixtures. We also consider porous particles accounting on voids in the spheroids through effective medium approach. The roughness of the spheroids is considered as a normal distribution of particle surface slopes and can be of different degree depending on the standard deviation of the distribution, σ, where σ=0 corresponds to smooth surface and σ=0.5 describes severely rough surface (see Young et al., J. Atm. Sci., 70, 330, 2012). We perform computations for two wavelengths, typical for blue (447nm) and red (640nm) cometary continuum filters. We compare phase angle dependence of polarization and brightness and their spectral change obtained with the rough-spheroid model with those observed for comets (e.g. Kolokolova et al., In: Comets 2, Arizona Press, 577, 2004) to see how well rough spheroids can reproduce cometary low albedo, red color, red polarimetric color, negative polarization at small phase angles and polarization maximum at medium phase angles.

  2. Exploring the mechanisms of vehicle front-end shape on pedestrian head injuries caused by ground impact.

    PubMed

    Yin, Sha; Li, Jiani; Xu, Jun

    2017-09-01

    In pedestrian-vehicle accidents, pedestrians typically suffer from secondary impact with the ground after the primary contact with vehicles. However, information about the fundamental mechanism of pedestrian head injury from ground impact remains minimal, thereby hindering further improvement in pedestrian safety. This study addresses this issue by using multi-body modeling and computation to investigate the influence of vehicle front-end shape on pedestrian safety. Accordingly, a simulation matrix is constructed to vary bonnet leading-edge height, bonnet length, bonnet angle, and windshield angle. Subsequently, a set of 315 pedestrian-vehicle crash simulations are conducted using the multi-body simulation software MADYMO. Three vehicle velocities, i.e., 20, 30, and 40km/h, are set as the scenarios. Results show that the top governing factor is bonnet leading-edge height. The posture and head injury at the instant of head ground impact vary dramatically with increasing height because of the significant rise of the body bending point and the movement of the collision point. The bonnet angle is the second dominant factor that affects head-ground injury, followed by bonnet length and windshield angle. The results may elucidate one of the critical barriers to understanding head injury caused by ground impact and provide a solid theoretical guideline for considering pedestrian safety in vehicle design. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Cardiac MR in robotic heart surgery for preoperative identification of the target vessel and precise port placement--a theoretical model.

    PubMed

    Bergmann, P; Huber, S; Segl, H; Maechler, H; Reiter, U; Reiter, G; Rienmueller, R; Oberwalder, P; Rigler, B

    2003-08-01

    The identification of the ideal anastomosis site and the proper port placement are critical for the success of closed-chest robotic surgery. We investigated a new systematic procedure for precise port placement for TECABs. We used trigonometry and a human thoracic model to determine the optimal working angles between anastomotic plane, instruments, and endoscope. We then applied the results to seven human subjects as follows: 1. A navigation grid was located extrathoracically before cardiac MR examination. 2. The ideal anastomosis site was defined with the MR. Intrathoracic distances and angles were computed with cardiac MR software and projected onto the thorax. 3. The ideal port placement points were marked on the thorax. The optimal working angle between endoscope and instruments was 35 degrees. 0 degrees and 90 degrees angles were associated with a significant reduction in visualization, technical ease, quality and anastomosis time. The course of the LAD was identified in all seven volunteers with MR. Mean deviation of the endoscope port from the medioclavicular line was 4.3+/-2.1 cm and of the instrument ports from the anterior axillary line 8.4+/-2.4 cm. Cardiac MR in combination with the navigation grid proved suitable for the visualization of coronary vessels for individually calculating port placement points on the thorax.

  4. Investigating the geometry of pig airways using computed tomography

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Azad, Md Khurshidul; McMurray, Brandon; Henry, Brian; Royston, Thomas J.; Sandler, Richard H.

    2015-03-01

    Numerical modeling of sound propagation in the airways requires accurate knowledge of the airway geometry. These models are often validated using human and animal experiments. While many studies documented the geometric details of the human airways, information about the geometry of pig airways is scarcer. In addition, the morphology of animal airways can be significantly different from that of humans. The objective of this study is to measure the airway diameter, length and bifurcation angles in domestic pigs using computed tomography. After imaging the lungs of 3 pigs, segmentation software tools were used to extract the geometry of the airway lumen. The airway dimensions were then measured from the resulting 3 D models for the first 10 airway generations. Results showed that the size and morphology of the airways of different animals were similar. The measured airway dimensions were compared with those of the human airways. While the trachea diameter was found to be comparable to the adult human, the diameter, length and branching angles of other airways were noticeably different from that of humans. For example, pigs consistently had an early airway branching from the trachea that feeds the superior (top) right lung lobe proximal to the carina. This branch is absent in the human airways. These results suggested that the human geometry may not be a good approximation of the pig airways and may contribute to increasing the errors when the human airway geometric values are used in computational models of the pig chest.

  5. 48 CFR 352.227-14 - Rights in Data-Exceptional Circumstances.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....] Computer database or database means a collection of recorded information in a form capable of, and for the... databases or computer software documentation. Computer software documentation means owner's manuals, user's... nature (including computer databases and computer software documentation). This term does not include...

  6. 48 CFR 227.7203-5 - Government rights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software and Computer Software Documentation 227.7203-5 Government rights. The standard license rights in computer software that a licensor grants to the Government are unlimited rights, government purpose rights, or restricted rights. The standard license in computer software documentation conveys unlimited...

  7. 48 CFR 227.7203-5 - Government rights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software and Computer Software Documentation 227.7203-5 Government rights. The standard license rights in computer software that a licensor grants to the Government are unlimited rights, government purpose rights, or restricted rights. The standard license in computer software documentation conveys unlimited...

  8. 48 CFR 227.7203-5 - Government rights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software and Computer Software Documentation 227.7203-5 Government rights. The standard license rights in computer software that a licensor grants to the Government are unlimited rights, government purpose rights, or restricted rights. The standard license in computer software documentation conveys unlimited...

  9. 48 CFR 227.7203-5 - Government rights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software and Computer Software Documentation 227.7203-5 Government rights. The standard license rights in computer software that a licensor grants to the Government are unlimited rights, government purpose rights, or restricted rights. The standard license in computer software documentation conveys unlimited...

  10. 48 CFR 227.7203-5 - Government rights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software and Computer Software Documentation 227.7203-5 Government rights. The standard license rights in computer software that a licensor grants to the Government are unlimited rights, government purpose rights, or restricted rights. The standard license in computer software documentation conveys unlimited...

  11. Tables for Supersonic Flow Around Right Circular Cones at Small Angle of Attack

    NASA Technical Reports Server (NTRS)

    Sims, Joseph L.

    1964-01-01

    The solution of supersonic flow fields by the method of characteristics requires that starting conditions be known. Ferri, in reference 1, developed a method-of-characteristics solution for axially symmetric bodies of revolution at small angles of attack. With computing machinery that is now available, this has become a feasible method for computing the aerodynamic characteristics of bodies near zero angle of attack. For sharp-nosed bodies of revolution, the required starting line may be obtained by computing the flow field about a cone at a small angle of attack. This calculation is readily performed using Stone's theory in reference 2. Some solutions of this theory are available in reference 3. However, the manner in which these results are presented, namely in a wind-fixed coordinate system, makes their use somewhat cumbersome. Additionally, as pointed out in reference 4, the flow component perpendicular to the meridian planes was computed incorrectly. The results contained herein have been computed in the same basic manner as those of reference 3 with the correct velocity normal to the meridian planes. Also, all results have been transferred into the body-fixed coordinate system. Therefore, the values tabulated herein may be used, in conjunction with the respective zero-angle-of-attack results of reference 5, as starting conditions for the method-of-characteristics solution of the flow field about axially symmetric bodies of revolution at small angles of attack. As in the zero-angle-of-attack case (ref. 5) the present results have been computed using the ideal gas value of 1.4 for the ratio of the specific heats of air. Solutions are given for cone angles from 2.5 deg to 30 deg in increments of 2.5 deg. For each cone angle, results were computed for a constant series of free-stream Mach numbers from 1.5 to 20. In addition, a solution was computed which yielded the minimum free-stream Mach number for a completely supersonic conical flow field. For cone angles of 27.5 deg and 30 deg, this minimum free-stream Mach number was above 1.5. Consequently, solutions at this Mach number were not computed for these two cone angles.

  12. Torsional Angle Driver (TorAD) System for HyperChem/Excel

    NASA Astrophysics Data System (ADS)

    Starkey, Ronald

    1999-02-01

    The torsional angle driver system for HyperChem/Excel is a package of several Excel spreadsheets and macro programs to be used with HyperChem to obtain and plot information, such as total energy, for the conformations that result from a 360° rotation about a torsional angle system in a molecule. The TorAD system also includes several HyperChem scripts to facilitate its use. TorAD was developed for use in the undergraduate organic chemistry laboratory. The results obtained with TorAD could be obtained manually with HyperChem, but it would take considerable time and would not be instructive to the students. Use of the TorAD system allows students to spend their time on the more important aspect of conformation analysisinterpretation of results. The Excel spreadsheet/macro programs in TorAD include:

    · Tor_xl_a and tor_xl obtain and plot the total energy at 5° torsional-angle intervals. The calculation method, the torsional-angle restraint, and the structure to be used at each angle can be set by the user. The advanced version, tor_xl_a, which requires HyperChem 4.5 or later, also allows torsional-angle structures to be saved for later recall as individual structures or, using a HyperChem script, in a movie format. It also provides a rapid scan of the 360° rotation where only single-point calculations, rather than geometry optimizations, are performed. The tor_xl system will perform routine tasks in a manner suitable for most instructional settings. · Tor_Comp performs molecular mechanics optimizations at 5° intervals and obtains and plots four energy parameters (total, torsional, nonbonded, and bond [bend plus stretch] energy) as a function of torsional angle. The calculation method and the restraint can be specified. · TorDipol produces a plot of the total energy and the calculated dipole moment at 5° steps of the torsional angle. The default calculation is the semi-empirical AM1 method, but other methods can be used. The calculation method and the restraint can be specified. · Tor2_180 and Tor2_360 rotate two torsional angles to provide a 3D plot of the resulting total energy surface. Tor2_180 performs a 0 to 180° rotation, in 10° steps, on each of the two torsional angle systems (tor1 and tor2) selected. Tor2_360 will do a -180° to +180° (360° total) rotation of the two torsional angles in 20° steps.
    Both tor2_180 and tor2_360 provide an x, y, z plot (x = angle 1, y = angle 2, z = energy) and a topo plot (x = angle 1, y = angle 2, z = topo lines and color coding). The molecular mechanics method and the restraint can be specified. Hardware and Software Requirement Hardware and software requirements for Torsional Angle Driver (TorAD) are shown in Table 1. These programs require a version of HyperChem 4.0 or later that supports DDE. Also required is Microsoft Excel 5.0 or higher. HyperChem and Excel are not included with the issue.
    Ordering and Information JCE Software is a publication of the Journal of Chemical Education. There is an order form inserted in this issue that provides prices and other ordering information. If this card is not available or if you need additional information, contact: JCE Software, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706-1396 phone: 608/262-5153 or 800/991-5534 fax: 608/265-8094; email: jcesoft@chem.wisc.edu Information about all of our publications (including abstracts, descriptions, updates) is available from the JCE Software World Wide Web site.

  13. An automatic tooth preparation technique: A preliminary study

    NASA Astrophysics Data System (ADS)

    Yuan, Fusong; Wang, Yong; Zhang, Yaopeng; Sun, Yuchun; Wang, Dangxiao; Lyu, Peijun

    2016-04-01

    The aim of this study is to validate the feasibility and accuracy of a new automatic tooth preparation technique in dental healthcare. An automatic tooth preparation robotic device with three-dimensional motion planning software was developed, which controlled an ultra-short pulse laser (USPL) beam (wavelength 1,064 nm, pulse width 15 ps, output power 30 W, and repeat frequency rate 100 kHz) to complete the tooth preparation process. A total of 15 freshly extracted human intact first molars were collected and fixed into a phantom head, and the target preparation shapes of these molars were designed using customised computer-aided design (CAD) software. The accuracy of tooth preparation was evaluated using the Geomagic Studio and Imageware software, and the preparing time of each tooth was recorded. Compared with the target preparation shape, the average shape error of the 15 prepared molars was 0.05-0.17 mm, the preparation depth error of the occlusal surface was approximately 0.097 mm, and the error of the convergence angle was approximately 1.0°. The average preparation time was 17 minutes. These results validated the accuracy and feasibility of the automatic tooth preparation technique.

  14. An automatic tooth preparation technique: A preliminary study.

    PubMed

    Yuan, Fusong; Wang, Yong; Zhang, Yaopeng; Sun, Yuchun; Wang, Dangxiao; Lyu, Peijun

    2016-04-29

    The aim of this study is to validate the feasibility and accuracy of a new automatic tooth preparation technique in dental healthcare. An automatic tooth preparation robotic device with three-dimensional motion planning software was developed, which controlled an ultra-short pulse laser (USPL) beam (wavelength 1,064 nm, pulse width 15 ps, output power 30 W, and repeat frequency rate 100 kHz) to complete the tooth preparation process. A total of 15 freshly extracted human intact first molars were collected and fixed into a phantom head, and the target preparation shapes of these molars were designed using customised computer-aided design (CAD) software. The accuracy of tooth preparation was evaluated using the Geomagic Studio and Imageware software, and the preparing time of each tooth was recorded. Compared with the target preparation shape, the average shape error of the 15 prepared molars was 0.05-0.17 mm, the preparation depth error of the occlusal surface was approximately 0.097 mm, and the error of the convergence angle was approximately 1.0°. The average preparation time was 17 minutes. These results validated the accuracy and feasibility of the automatic tooth preparation technique.

  15. A determination of occlusal plane comparing different levels of the tragus to form ala-tragal line or Camper's line: A photographic study.

    PubMed

    Kumar, Sandeep; Garg, Sandeep; Gupta, Seema

    2013-02-01

    The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane (OT1-OP), Eye-Ear plane and ala-superior border of tragus (OT1-AT1), Eye-Ear plane and ala-middle border of tragus (OT1-AT2) and Eye-Ear plane and ala-inferior border of tragus (OT1-AT3) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane (OT1 or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane (OT1) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. The mean of base line angle i.e. OT1-OP angle (11.96 ± 4.36) was found to be close to OT1-AT2 angle (13.67 ± 1.93) and OT1-AT3 angle (10.31 ± 2.03), but OT1-OP angle was found to be more closer to OT1-AT3 angle. Comparison of mean angles showed that OT1-OP angle in both males (11.68) and females (12.51) is close to OT1-AT3 angle (males- 11.01, females- 11.95). The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane.

  16. A determination of occlusal plane comparing different levels of the tragus to form ala-tragal line or Camper's line: A photographic study

    PubMed Central

    Garg, Sandeep; Gupta, Seema

    2013-01-01

    PURPOSE The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. MATERIALS AND METHODS 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane (OT1-OP), Eye-Ear plane and ala-superior border of tragus (OT1-AT1), Eye-Ear plane and ala-middle border of tragus (OT1-AT2) and Eye-Ear plane and ala-inferior border of tragus (OT1-AT3) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane (OT1 or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane (OT1) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. RESULTS The mean of base line angle i.e. OT1-OP angle (11.96 ± 4.36) was found to be close to OT1-AT2 angle (13.67 ± 1.93) and OT1-AT3 angle (10.31 ± 2.03), but OT1-OP angle was found to be more closer to OT1-AT3 angle. Comparison of mean angles showed that OT1-OP angle in both males (11.68) and females (12.51) is close to OT1-AT3 angle (males- 11.01, females- 11.95). CONCLUSION The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane. PMID:23508203

  17. 48 CFR 27.405-3 - Commercial computer software.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software. 27.405-3 Section 27.405-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Commercial computer software. (a) When contracting other than from GSA's Multiple Award Schedule contracts for the acquisition of commercial computer software, no specific contract clause prescribed in this...

  18. 48 CFR 27.405-3 - Commercial computer software.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software. 27.405-3 Section 27.405-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Commercial computer software. (a) When contracting other than from GSA's Multiple Award Schedule contracts for the acquisition of commercial computer software, no specific contract clause prescribed in this...

  19. 48 CFR 27.405-3 - Commercial computer software.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software. 27.405-3 Section 27.405-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Commercial computer software. (a) When contracting other than from GSA's Multiple Award Schedule contracts for the acquisition of commercial computer software, no specific contract clause prescribed in this...

  20. 48 CFR 27.405-3 - Commercial computer software.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software. 27.405-3 Section 27.405-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Commercial computer software. (a) When contracting other than from GSA's Multiple Award Schedule contracts for the acquisition of commercial computer software, no specific contract clause prescribed in this...

  1. 48 CFR 27.405-3 - Commercial computer software.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software. 27.405-3 Section 27.405-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Commercial computer software. (a) When contracting other than from GSA's Multiple Award Schedule contracts for the acquisition of commercial computer software, no specific contract clause prescribed in this...

  2. Play dough as an educational tool for visualization of complicated cerebral aneurysm anatomy

    PubMed Central

    Eftekhar, Behzad; Ghodsi, Mohammad; Ketabchi, Ebrahim; Ghazvini, Arman Rakan

    2005-01-01

    Background Imagination of the three-dimensional (3D) structure of cerebral vascular lesions using two-dimensional (2D) angiograms is one of the skills that neurosurgical residents should achieve during their training. Although ongoing progress in computer software and digital imaging systems has facilitated viewing and interpretation of cerebral angiograms enormously, these facilities are not always available. Methods We have presented the use of play dough as an adjunct to the teaching armamentarium for training in visualization of cerebral aneurysms in some cases. Results The advantages of play dough are low cost, availability and simplicity of use, being more efficient and realistic in training the less experienced resident in comparison with the simple drawings and even angiographic views from different angles without the need for computers and similar equipment. The disadvantages include the psychological resistance of residents to the use of something in surgical training that usually is considered to be a toy, and not being as clean as drawings or computerized images. Conclusion Although technology and computerized software using the patients' own imaging data seems likely to become more advanced in the future, use of play dough in some complicated cerebral aneurysm cases may be helpful in 3D reconstruction of the real situation. PMID:15885141

  3. Trends in computer hardware and software.

    PubMed

    Frankenfeld, F M

    1993-04-01

    Previously identified and current trends in the development of computer systems and in the use of computers for health care applications are reviewed. Trends identified in a 1982 article were increasing miniaturization and archival ability, increasing software costs, increasing software independence, user empowerment through new software technologies, shorter computer-system life cycles, and more rapid development and support of pharmaceutical services. Most of these trends continue today. Current trends in hardware and software include the increasing use of reduced instruction-set computing, migration to the UNIX operating system, the development of large software libraries, microprocessor-based smart terminals that allow remote validation of data, speech synthesis and recognition, application generators, fourth-generation languages, computer-aided software engineering, object-oriented technologies, and artificial intelligence. Current trends specific to pharmacy and hospitals are the withdrawal of vendors of hospital information systems from the pharmacy market, improved linkage of information systems within hospitals, and increased regulation by government. The computer industry and its products continue to undergo dynamic change. Software development continues to lag behind hardware, and its high cost is offsetting the savings provided by hardware.

  4. 48 CFR 52.227-19 - Commercial Computer Software License.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Software License. 52.227-19 Section 52.227-19 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.227-19 Commercial Computer Software License. As prescribed in 27.409(g), insert the following clause: Commercial Computer Software License (DEC 2007) (a) Notwithstanding any contrary provisions...

  5. 48 CFR 52.227-19 - Commercial Computer Software License.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Software License. 52.227-19 Section 52.227-19 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.227-19 Commercial Computer Software License. As prescribed in 27.409(g), insert the following clause: Commercial Computer Software License (DEC 2007) (a) Notwithstanding any contrary provisions...

  6. 48 CFR 52.227-19 - Commercial Computer Software License.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Software License. 52.227-19 Section 52.227-19 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.227-19 Commercial Computer Software License. As prescribed in 27.409(g), insert the following clause: Commercial Computer Software License (DEC 2007) (a) Notwithstanding any contrary provisions...

  7. 48 CFR 52.227-19 - Commercial Computer Software License.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Software License. 52.227-19 Section 52.227-19 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.227-19 Commercial Computer Software License. As prescribed in 27.409(g), insert the following clause: Commercial Computer Software License (DEC 2007) (a) Notwithstanding any contrary provisions...

  8. 48 CFR 52.227-19 - Commercial Computer Software License.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Software License. 52.227-19 Section 52.227-19 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.227-19 Commercial Computer Software License. As prescribed in 27.409(g), insert the following clause: Commercial Computer Software License (DEC 2007) (a) Notwithstanding any contrary provisions...

  9. Automated computation of femoral angles in dogs from three-dimensional computed tomography reconstructions: Comparison with manual techniques.

    PubMed

    Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M

    2018-02-01

    The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. 10 CFR 961.11 - Text of the contract.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... program including information on cost projections, project plans and progress reports. 5. (a) Beginning on...-type documents or computer software (including computer programs, computer software data bases, and computer software documentation). Examples of technical data include research and engineering data...

  11. 10 CFR 961.11 - Text of the contract.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... program including information on cost projections, project plans and progress reports. 5. (a) Beginning on...-type documents or computer software (including computer programs, computer software data bases, and computer software documentation). Examples of technical data include research and engineering data...

  12. EOS MLS Level 1B Data Processing Software. Version 3

    NASA Technical Reports Server (NTRS)

    Perun, Vincent S.; Jarnot, Robert F.; Wagner, Paul A.; Cofield, Richard E., IV; Nguyen, Honghanh T.; Vuu, Christina

    2011-01-01

    This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.

  13. Microcomputer software development facilities

    NASA Technical Reports Server (NTRS)

    Gorman, J. S.; Mathiasen, C.

    1980-01-01

    A more efficient and cost effective method for developing microcomputer software is to utilize a host computer with high-speed peripheral support. Application programs such as cross assemblers, loaders, and simulators are implemented in the host computer for each of the microcomputers for which software development is a requirement. The host computer is configured to operate in a time share mode for multiusers. The remote terminals, printers, and down loading capabilities provided are based on user requirements. With this configuration a user, either local or remote, can use the host computer for microcomputer software development. Once the software is developed (through the code and modular debug stage) it can be downloaded to the development system or emulator in a test area where hardware/software integration functions can proceed. The microcomputer software program sources reside in the host computer and can be edited, assembled, loaded, and then downloaded as required until the software development project has been completed.

  14. Software For Computing Reliability Of Other Software

    NASA Technical Reports Server (NTRS)

    Nikora, Allen; Antczak, Thomas M.; Lyu, Michael

    1995-01-01

    Computer Aided Software Reliability Estimation (CASRE) computer program developed for use in measuring reliability of other software. Easier for non-specialists in reliability to use than many other currently available programs developed for same purpose. CASRE incorporates mathematical modeling capabilities of public-domain Statistical Modeling and Estimation of Reliability Functions for Software (SMERFS) computer program and runs in Windows software environment. Provides menu-driven command interface; enabling and disabling of menu options guides user through (1) selection of set of failure data, (2) execution of mathematical model, and (3) analysis of results from model. Written in C language.

  15. 48 CFR 239.101 - Policy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... See Subpart 208.74 when acquiring commercial software or software maintenance. See 227.7202 for policy on the acquisition of commercial computer software and commercial computer software documentation...

  16. 48 CFR 239.101 - Policy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... See Subpart 208.74 when acquiring commercial software or software maintenance. See 227.7202 for policy on the acquisition of commercial computer software and commercial computer software documentation...

  17. 48 CFR 239.101 - Policy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... See Subpart 208.74 when acquiring commercial software or software maintenance. See 227.7202 for policy on the acquisition of commercial computer software and commercial computer software documentation...

  18. 48 CFR 239.101 - Policy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... See Subpart 208.74 when acquiring commercial software or software maintenance. See 227.7202 for policy on the acquisition of commercial computer software and commercial computer software documentation...

  19. 48 CFR 239.101 - Policy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... See Subpart 208.74 when acquiring commercial software or software maintenance. See 227.7202 for policy on the acquisition of commercial computer software and commercial computer software documentation...

  20. 37 CFR 201.26 - Recordation of documents pertaining to computer shareware and donation of public domain computer...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pertaining to computer shareware and donation of public domain computer software. 201.26 Section 201.26... of public domain computer software. (a) General. This section prescribes the procedures for... software under section 805 of Public Law 101-650, 104 Stat. 5089 (1990). Documents recorded in the...

  1. 77 FR 50723 - Verification, Validation, Reviews, and Audits for Digital Computer Software Used in Safety...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... Digital Computer Software Used in Safety Systems of Nuclear Power Plants AGENCY: Nuclear Regulatory..., ``Verification, Validation, Reviews, and Audits for Digital Computer Software used in Safety Systems of Nuclear... NRC regulations promoting the development of, and compliance with, software verification and...

  2. 48 CFR 970.5227-1 - Rights in data-facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software. (2) Computer software, as used in this clause, means (i) computer programs which are data... software. The term “data” does not include data incidental to the administration of this contract, such as... this clause, means data, other than computer software, developed at private expense that embody trade...

  3. Factors leading to the computer vision syndrome: an issue at the contemporary workplace.

    PubMed

    Izquierdo, Juan C; García, Maribel; Buxó, Carmen; Izquierdo, Natalio J

    2007-01-01

    Vision and eye related problems are common among computer users, and have been collectively called the Computer Vision Syndrome (CVS). An observational study in order to identify the risk factors leading to the CVS was done. Twenty-eight participants answered a validated questionnaire, and had their workstations examined. The questionnaire evaluated personal, environmental, ergonomic factors, and physiologic response of computer users. The distance from the eye to the computers' monitor (A), the computers' monitor height (B), and visual axis height (C) were measured. The difference between B and C was calculated and labeled as D. Angles of gaze to the computer monitor were calculated using the formula: angle=tan-1(D/A). Angles were divided into two groups: participants with angles of gaze ranging from 0 degree to 13.9 degrees were included in Group 1; and participants gazing at angles larger than 14 degrees were included in Group 2. Statistical analysis of the evaluated variables was made. Computer users in both groups used more tear supplements (as part of the syndrome) than expected. This association was statistically significant (p < 0.10). Participants in Group 1 reported more pain than participants in Group 2. Associations between the CVS and other personal or ergonomic variables were not statistically significant. Our findings show that the most important factor leading to the syndrome is the angle of gaze at the computer monitor. Pain in computer users is diminished when gazing downwards at angles of 14 degrees or more. The CVS remains an under estimated and poorly understood issue at the workplace. The general public, health professionals, the government, and private industries need to be educated about the CVS.

  4. Factors leading to the Computer Vision Syndrome: an issue at the contemporary workplace.

    PubMed

    Izquierdo, Juan C; García, Maribel; Buxó, Carmen; Izquierdo, Natalio J

    2004-01-01

    Vision and eye related problems are common among computer users, and have been collectively called the Computer Vision Syndrome (CVS). An observational study in order to identify the risk factors leading to the CVS was done. Twenty-eight participants answered a validated questionnaire, and had their workstations examined. The questionnaire evaluated personal, environmental, ergonomic factors, and physiologic response of computer users. The distance from the eye to the computers' monitor (A), the computers' monitor height (B), and visual axis height (C) were measured. The difference between B and C was calculated and labeled as D. Angles of gaze to the computer monitor were calculated using the formula: angle=tan(-1)(D/ A). Angles were divided into two groups: participants with angles of gaze ranging from 0 degrees to 13.9 degrees were included in Group 1; and participants gazing at angles larger than 14 degrees were included in Group 2. Statistical analysis of the evaluated variables was made. Computer users in both groups used more tear supplements (as part of the syndrome) than expected. This association was statistically significant (p<0.10). Participants in Group 1 reported more pain than participants in Group 2. Associations between the CVS and other personal or ergonomic variables were not statistically significant. Our findings show that most important factor leading to the syndrome is the angle of gaze at the computer monitor. Pain in computer users is diminished when gazing downwards at angles of 14 degrees or more. The CVS remains an under estimated and poorly understood issue at the workplace. The general public, health professionals, the government, and private industries need to be educated about the CVS.

  5. Computation of the inviscid supersonic flow about cones at large angles of attack by a floating discontinuity approach

    NASA Technical Reports Server (NTRS)

    Daywitt, J.; Kutler, P.; Anderson, D.

    1977-01-01

    The technique of floating shock fitting is adapted to the computation of the inviscid flowfield about circular cones in a supersonic free stream at angles of attack that exceed the cone half-angle. The resulting equations are applicable over the complete range of free-stream Mach numbers, angles of attack and cone half-angles for which the bow shock is attached. A finite difference algorithm is used to obtain the solution by an unsteady relaxation approach. The bow shock, embedded cross-flow shock, and vortical singularity in the leeward symmetry plane are treated as floating discontinuities in a fixed computational mesh. Where possible, the flowfield is partitioned into windward, shoulder, and leeward regions with each region computed separately to achieve maximum computational efficiency. An alternative shock fitting technique which treats the bow shock as a computational boundary is developed and compared with the floating-fitting approach. Several surface boundary condition schemes are also analyzed.

  6. Geodetic Strain Analysis Tool

    NASA Technical Reports Server (NTRS)

    Kedar, Sharon; Baxter, Sean C.; Parker, Jay W.; Webb, Frank H.; Owen, Susan E.; Sibthorpe, Anthony J.; Dong, Danan

    2011-01-01

    A geodetic software analysis tool enables the user to analyze 2D crustal strain from geodetic ground motion, and create models of crustal deformation using a graphical interface. Users can use any geodetic measurements of ground motion and derive the 2D crustal strain interactively. This software also provides a forward-modeling tool that calculates a geodetic velocity and strain field for a given fault model, and lets the user compare the modeled strain field with the strain field obtained from the user s data. Users may change parameters on-the-fly and obtain a real-time recalculation of the resulting strain field. Four data products are computed: maximum shear, dilatation, shear angle, and principal components. The current view and data dependencies are processed first. The remaining data products and views are then computed in a round-robin fashion to anticipate view changes. When an analysis or display parameter is changed, the affected data products and views are invalidated and progressively re-displayed as available. This software is designed to facilitate the derivation of the strain fields from the GPS and strain meter data that sample it to facilitate the understanding of the strengths and weaknesses of the strain field derivation from continuous GPS (CGPS) and other geodetic data from a variety of tectonic settings, to converge on the "best practices" strain derivation strategy for the Solid Earth Science ESDR System (SESES) project given the CGPS station distribution in the western U.S., and to provide SESES users with a scientific and educational tool to explore the strain field on their own with user-defined parameters.

  7. Computer-aided analysis of cutting processes for brittle materials

    NASA Astrophysics Data System (ADS)

    Ogorodnikov, A. I.; Tikhonov, I. N.

    2017-12-01

    This paper is focused on 3D computer simulation of cutting processes for brittle materials and silicon wafers. Computer-aided analysis of wafer scribing and dicing is carried out with the use of the ANSYS CAE (computer-aided engineering) software, and a parametric model of the processes is created by means of the internal ANSYS APDL programming language. Different types of tool tip geometry are analyzed to obtain internal stresses, such as a four-sided pyramid with an included angle of 120° and a tool inclination angle to the normal axis of 15°. The quality of the workpieces after cutting is studied by optical microscopy to verify the FE (finite-element) model. The disruption of the material structure during scribing occurs near the scratch and propagates into the wafer or over its surface at a short range. The deformation area along the scratch looks like a ragged band, but the stress width is rather low. The theory of cutting brittle semiconductor and optical materials is developed on the basis of the advanced theory of metal turning. The fall of stress intensity along the normal on the way from the tip point to the scribe line can be predicted using the developed theory and with the verified FE model. The crystal quality and dimensions of defects are determined by the mechanics of scratching, which depends on the shape of the diamond tip, the scratching direction, the velocity of the cutting tool and applied force loads. The disunity is a rate-sensitive process, and it depends on the cutting thickness. The application of numerical techniques, such as FE analysis, to cutting problems enhances understanding and promotes the further development of existing machining technologies.

  8. Dynamic Right Triangles

    ERIC Educational Resources Information Center

    Koyunkaya, Melike Yigit; Kastberg, Signe; Quinlan, James; Edwards, Michael Todd; Keiser, Jane

    2015-01-01

    Right triangles play a significant role in mathematics. In this favorite lesson, the authors help students understand variant and invariant properties by considering relationships among angle measures and side lengths in right triangles. Students explore these relationships using interactive mathematics software, changing one angle and observing…

  9. The effect of cleft maxillary distraction osteogenesis on the levator veli palatini and velopharyngeal function.

    PubMed

    Chen, Philip Kuo-Ting; Por, Yong-Chen; Liou, Eric Jein-Wein; Chang, Frank Chun-Shin

    2015-05-01

    Le Fort I maxillary distraction with the rigid external distraction (RED) device is performed to correct severe midface retrusion in cleft patients, but it may adversely affect velopharyngeal function. This study aims to investigate the angular changes in the levator veli palatini (LVP) and its influence on velopharyngeal function after maxillary distraction using 3-dimensional computed tomography (3D CT) scan volume rendered images. This was a retrospective study of 12 patients. Group 1 had no velopharyngeal function deterioration and group 2 had velopharyngeal function deterioration. Preoperative and 1 year postoperative CT scans were analyzed with Mimics v10 software. Segmentation of the LVP and the nasopharyngeal airway was performed and volumetric images were obtained. Six measurements were made: (1) the angle between the levator plane and the Frankfort horizontal, (2) the angle between the levator plane and the soft palate plane, (3) the angle between the 2 LVP muscles, (4) the pharyngeal depth, and (5, 6) the movement of the inferior pharyngeal point with respect to the horizontal and vertical planes. The independent samples t test, Mann-Whitney test, and paired t tests were used for statistical analyses (P < 0.05). Group 2 had statistically significant reduction in the angle between the levator plane and Frankfort horizontal as well as the soft palate plane. Group 1 had a statistically significant increase in the pharyngeal depth and movement of the inferior pharyngeal point with respect to the horizontal plane. A decrease in the angle between the levator plane and the Frankfort horizontal or the soft palate plane was associated with velopharyngeal function deterioration.

  10. Agreement Between Face-to-Face and Free Software Video Analysis for Assessing Hamstring Flexibility in Adolescents.

    PubMed

    Moral-Muñoz, José A; Esteban-Moreno, Bernabé; Arroyo-Morales, Manuel; Cobo, Manuel J; Herrera-Viedma, Enrique

    2015-09-01

    The objective of this study was to determine the level of agreement between face-to-face hamstring flexibility measurements and free software video analysis in adolescents. Reduced hamstring flexibility is common in adolescents (75% of boys and 35% of girls aged 10). The length of the hamstring muscle has an important role in both the effectiveness and the efficiency of basic human movements, and reduced hamstring flexibility is related to various musculoskeletal conditions. There are various approaches to measuring hamstring flexibility with high reliability; the most commonly used approaches in the scientific literature are the sit-and-reach test, hip joint angle (HJA), and active knee extension. The assessment of hamstring flexibility using video analysis could help with adolescent flexibility follow-up. Fifty-four adolescents from a local school participated in a descriptive study of repeated measures using a crossover design. Active knee extension and HJA were measured with an inclinometer and were simultaneously recorded with a video camera. Each video was downloaded to a computer and subsequently analyzed using Kinovea 0.8.15, a free software application for movement analysis. All outcome measures showed reliability estimates with α > 0.90. The lowest reliability was obtained for HJA (α = 0.91). The preliminary findings support the use of a free software tool for assessing hamstring flexibility, offering health professionals a useful tool for adolescent flexibility follow-up.

  11. 1989-90 Statewide Computer Survey Report.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Instructional Technology.

    This report presents the findings from South Carolina's seventh statewide computer survey. The survey solicited information on computer equipment and software, and dealt with such issues as the instructional and administrative uses of computers and the availability and use of Software Evaluation Exchange Dissemination (SEED) software reviews and a…

  12. Pitch Angles Of Artificially Redshifted Galaxies

    NASA Astrophysics Data System (ADS)

    Shields, Douglas W.; Davis, B.; Johns, L.; Berrier, J. C.; Kennefick, D.; Kennefick, J.; Seigar, M.

    2012-05-01

    We present the pitch angles of several galaxies that have been artificially redshifted using Barden et al’s FERENGI software. The (central black hole mass)-(spiral arm pitch angle) relation has been used on a statistically complete sample of local galaxies to determine the black hole mass function of local spiral galaxies. We now measure the pitch angles at increasing redshifts by operating on the images pixel-by-pixel. The results will be compared to the pitch angle function as measured in the GOODS field. This research was funded in part by NASA / EPScOR.

  13. Non-developmental item computer systems and the malicious software threat

    NASA Technical Reports Server (NTRS)

    Bown, Rodney L.

    1991-01-01

    The following subject areas are covered: a DOD development system - the Army Secure Operating System; non-development commercial computer systems; security, integrity, and assurance of service (SI and A); post delivery SI and A and malicious software; computer system unique attributes; positive feedback to commercial computer systems vendors; and NDI (Non-Development Item) computers and software safety.

  14. 48 CFR 252.227-7028 - Technical data or computer software previously delivered to the government.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software previously delivered to the government. 252.227-7028 Section 252.227-7028 Federal Acquisition... computer software previously delivered to the government. As prescribed in 227.7103-6(d), 227.7104(f)(2), or 227.7203-6(e), use the following provision: Technical Data or Computer Software Previously...

  15. 48 CFR 252.227-7028 - Technical data or computer software previously delivered to the government.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software previously delivered to the government. 252.227-7028 Section 252.227-7028 Federal Acquisition... computer software previously delivered to the government. As prescribed in 227.7103-6(d), 227.7104(f)(2), or 227.7203-6(e), use the following provision: Technical Data or Computer Software Previously...

  16. 48 CFR 252.227-7028 - Technical data or computer software previously delivered to the government.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software previously delivered to the government. 252.227-7028 Section 252.227-7028 Federal Acquisition... computer software previously delivered to the government. As prescribed in 227.7103-6(d), 227.7104(f)(2), or 227.7203-6(e), use the following provision: Technical Data or Computer Software Previously...

  17. 48 CFR 252.227-7028 - Technical data or computer software previously delivered to the government.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software previously delivered to the government. 252.227-7028 Section 252.227-7028 Federal Acquisition... computer software previously delivered to the government. As prescribed in 227.7103-6(d), 227.7104(f)(2), or 227.7203-6(e), use the following provision: Technical Data or Computer Software Previously...

  18. 48 CFR 252.227-7028 - Technical data or computer software previously delivered to the government.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software previously delivered to the government. 252.227-7028 Section 252.227-7028 Federal Acquisition... computer software previously delivered to the government. As prescribed in 227.7103-6(d), 227.7104(f)(2), or 227.7203-6(e), use the following provision: Technical Data or Computer Software Previously...

  19. Computer Software: Copyright and Licensing Considerations for Schools and Libraries. ERIC Digest.

    ERIC Educational Resources Information Center

    Reed, Mary Hutchings

    This digest notes that the terms and conditions of computer software package license agreements control the use of software in schools and libraries, and examines the implications of computer software license agreements for classroom use and for library lending policies. Guidelines are provided for interpreting the Copyright Act, and insuring the…

  20. Computing angle of arrival of radio signals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borchardt, John J.; Steele, David K.

    Various technologies pertaining to computing angle of arrival of radio signals are described. A system that is configured for computing the angle of arrival of a radio signal includes a cylindrical sheath wrapped around a cylindrical object, where the cylindrical sheath acts as a ground plane. The system further includes a plurality of antennas that are positioned about an exterior surface of the cylindrical sheath, and receivers respectively coupled to the antennas. The receivers output measurements pertaining to the radio signal. A processing circuit receives the measurements and computes the angle of arrival of the radio signal based upon themore » measurements.« less

  1. Tools for Administration of a UNIX-Based Network

    NASA Technical Reports Server (NTRS)

    LeClaire, Stephen; Farrar, Edward

    2004-01-01

    Several computer programs have been developed to enable efficient administration of a large, heterogeneous, UNIX-based computing and communication network that includes a variety of computers connected to a variety of subnetworks. One program provides secure software tools for administrators to create, modify, lock, and delete accounts of specific users. This program also provides tools for users to change their UNIX passwords and log-in shells. These tools check for errors. Another program comprises a client and a server component that, together, provide a secure mechanism to create, modify, and query quota levels on a network file system (NFS) mounted by use of the VERITAS File SystemJ software. The client software resides on an internal secure computer with a secure Web interface; one can gain access to the client software from any authorized computer capable of running web-browser software. The server software resides on a UNIX computer configured with the VERITAS software system. Directories where VERITAS quotas are applied are NFS-mounted. Another program is a Web-based, client/server Internet Protocol (IP) address tool that facilitates maintenance lookup of information about IP addresses for a network of computers.

  2. 77 FR 50724 - Developing Software Life Cycle Processes for Digital Computer Software Used in Safety Systems of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Developing Software Life Cycle Processes for Digital... Software Life Cycle Processes for Digital Computer Software used in Safety Systems of Nuclear Power Plants... clarifications, the enhanced consensus practices for developing software life-cycle processes for digital...

  3. Software platform virtualization in chemistry research and university teaching

    PubMed Central

    2009-01-01

    Background Modern chemistry laboratories operate with a wide range of software applications under different operating systems, such as Windows, LINUX or Mac OS X. Instead of installing software on different computers it is possible to install those applications on a single computer using Virtual Machine software. Software platform virtualization allows a single guest operating system to execute multiple other operating systems on the same computer. We apply and discuss the use of virtual machines in chemistry research and teaching laboratories. Results Virtual machines are commonly used for cheminformatics software development and testing. Benchmarking multiple chemistry software packages we have confirmed that the computational speed penalty for using virtual machines is low and around 5% to 10%. Software virtualization in a teaching environment allows faster deployment and easy use of commercial and open source software in hands-on computer teaching labs. Conclusion Software virtualization in chemistry, mass spectrometry and cheminformatics is needed for software testing and development of software for different operating systems. In order to obtain maximum performance the virtualization software should be multi-core enabled and allow the use of multiprocessor configurations in the virtual machine environment. Server consolidation, by running multiple tasks and operating systems on a single physical machine, can lead to lower maintenance and hardware costs especially in small research labs. The use of virtual machines can prevent software virus infections and security breaches when used as a sandbox system for internet access and software testing. Complex software setups can be created with virtual machines and are easily deployed later to multiple computers for hands-on teaching classes. We discuss the popularity of bioinformatics compared to cheminformatics as well as the missing cheminformatics education at universities worldwide. PMID:20150997

  4. Software platform virtualization in chemistry research and university teaching.

    PubMed

    Kind, Tobias; Leamy, Tim; Leary, Julie A; Fiehn, Oliver

    2009-11-16

    Modern chemistry laboratories operate with a wide range of software applications under different operating systems, such as Windows, LINUX or Mac OS X. Instead of installing software on different computers it is possible to install those applications on a single computer using Virtual Machine software. Software platform virtualization allows a single guest operating system to execute multiple other operating systems on the same computer. We apply and discuss the use of virtual machines in chemistry research and teaching laboratories. Virtual machines are commonly used for cheminformatics software development and testing. Benchmarking multiple chemistry software packages we have confirmed that the computational speed penalty for using virtual machines is low and around 5% to 10%. Software virtualization in a teaching environment allows faster deployment and easy use of commercial and open source software in hands-on computer teaching labs. Software virtualization in chemistry, mass spectrometry and cheminformatics is needed for software testing and development of software for different operating systems. In order to obtain maximum performance the virtualization software should be multi-core enabled and allow the use of multiprocessor configurations in the virtual machine environment. Server consolidation, by running multiple tasks and operating systems on a single physical machine, can lead to lower maintenance and hardware costs especially in small research labs. The use of virtual machines can prevent software virus infections and security breaches when used as a sandbox system for internet access and software testing. Complex software setups can be created with virtual machines and are easily deployed later to multiple computers for hands-on teaching classes. We discuss the popularity of bioinformatics compared to cheminformatics as well as the missing cheminformatics education at universities worldwide.

  5. Whole earth modeling: developing and disseminating scientific software for computational geophysics.

    NASA Astrophysics Data System (ADS)

    Kellogg, L. H.

    2016-12-01

    Historically, a great deal of specialized scientific software for modeling and data analysis has been developed by individual researchers or small groups of scientists working on their own specific research problems. As the magnitude of available data and computer power has increased, so has the complexity of scientific problems addressed by computational methods, creating both a need to sustain existing scientific software, and expand its development to take advantage of new algorithms, new software approaches, and new computational hardware. To that end, communities like the Computational Infrastructure for Geodynamics (CIG) have been established to support the use of best practices in scientific computing for solid earth geophysics research and teaching. Working as a scientific community enables computational geophysicists to take advantage of technological developments, improve the accuracy and performance of software, build on prior software development, and collaborate more readily. The CIG community, and others, have adopted an open-source development model, in which code is developed and disseminated by the community in an open fashion, using version control and software repositories like Git. One emerging issue is how to adequately identify and credit the intellectual contributions involved in creating open source scientific software. The traditional method of disseminating scientific ideas, peer reviewed publication, was not designed for review or crediting scientific software, although emerging publication strategies such software journals are attempting to address the need. We are piloting an integrated approach in which authors are identified and credited as scientific software is developed and run. Successful software citation requires integration with the scholarly publication and indexing mechanisms as well, to assign credit, ensure discoverability, and provide provenance for software.

  6. 48 CFR 252.204-7014 - Limitations on the Use or Disclosure of Information by Litigation Support Contractors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Computer software does not include computer data bases or computer software documentation. Litigation... includes technical data and computer software, but does not include information that is lawfully, publicly available without restriction. Technical data means recorded information, regardless of the form or method...

  7. Analysis of Software Systems for Specialized Computers,

    DTIC Science & Technology

    computer) with given computer hardware and software . The object of study is the software system of a computer, designed for solving a fixed complex of...purpose of the analysis is to find parameters that characterize the system and its elements during operation, i.e., when servicing the given requirement flow. (Author)

  8. Application of a 3-dimensional printed navigation template in Bernese periacetabular osteotomies: A cadaveric study.

    PubMed

    Zhou, You; Kang, Xiaopeng; Li, Chuan; Xu, Xiaoshan; Li, Rong; Wang, Jun; Li, Wei; Luo, Haotian; Lu, Sheng

    2016-12-01

    The aim of the present study was to describe the application of 3D printed templates for intraoperative navigation and simulation of periacetabular osteotomies (PAOs) in a cadaveric model.Five cadaveric specimens (10 sides) underwent thin-slice computed tomographic scans of the ala of ilium downwards to the proximal end of femoral shaft. Bernese PAO was performed. Using Mimics v10.1 software (Materialise, Leuven, Belgium), 3D computed tomographic reconstructions were created and the 4 standard PAO bone cuts-ischial, pubic, anterior, and posterior aspects of the ilium-as well as rotation of the dislocated acetabular bone blocks were simulated for each specimen. Using these data, custom 3D printed bone-drilling templates of the pelvis were manufactured, to guide surgical placement of the PAO bone cuts. An angle fix wedge was designed and printed, to help accurately achieve the predetermined rotation angle of the acetabular bone block. Each specimen underwent a conventional PAO. Preoperative, postsimulation, and postoperative lateral center-edge angles, acetabular indices, extrusion indices, and femoral head coverage were measured and compared; P and t values were calculated for above-mentioned measurements while comparing preoperative and postoperative data, and also in postsimulation and postoperative data comparison.All 10 PAO osteotomies were successfully completed using the 3D printed bone-drilling template and angle fix wedge. No osteotomy entered the hip joint and a single posterior column fracture was observed. Comparison of preoperative and postoperative measurements of the 10 sides showed statistically significant changes, whereas no statistically significant differences between postsimulation and postoperative values were noted, demonstrating the accuracy and utility of the 3D printed templates.The application of patient-specific 3D printed bone-drilling and rotation templates in PAO is feasible and may facilitate improved clinical outcomes, through the use of precise presurgical planning and reduced surgical complications with the precisely guided bone drilling.

  9. Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

    NASA Technical Reports Server (NTRS)

    Cater, Christopher; Xiao, Xinran; Goldberg, Robert K.; Kohlman, Lee W.

    2015-01-01

    A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles of 0deg, 30deg, 45deg, 60deg and 90deg relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

  10. Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

    NASA Technical Reports Server (NTRS)

    Cater, Christopher; Xiao, Xinran; Goldberg, Robert K.; Kohlman, Lee W.

    2015-01-01

    A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles [0deg, 30deg, 45deg, 60deg and 90deg] relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

  11. Study on temperature measurement of gas turbine blade based on analysis of error caused by the reflected radiation and emission angle

    NASA Astrophysics Data System (ADS)

    Li, Dong; Feng, Chi; Gao, Shan; Chen, Liwei; Daniel, Ketui

    2018-06-01

    Accurate measurement of gas turbine blade temperature is of great significance as far as blade health monitoring is concerned. An important method for measuring this temperature is the use of a radiation pyrometer. In this research, error of the pyrometer caused by reflected radiation from the surfaces surrounding the target and the emission angle of the target was analyzed. Important parameters for this analysis were the view factor between interacting surfaces, spectral directional emissivity, pyrometer operating wavelength and the surface temperature distribution on the blades and the vanes. The interacting surface of the rotor blade and the vane models used were discretized using triangular surface elements from which contour integral was used to calculate the view factor between the surface elements. Spectral directional emissivities were obtained from an experimental setup of Ni based alloy samples. A pyrometer operating wavelength of 1.6 μm was chosen. Computational fluid dynamics software was used to simulate the temperature distribution of the rotor blade and the guide vane based on the actual gas turbine input parameters. Results obtained in this analysis show that temperature error introduced by reflected radiation and emission angle ranges from  ‑23 K to 49 K.

  12. Vertical-angle control system in the LLMC

    NASA Astrophysics Data System (ADS)

    Li, Binhua; Yang, Lei; Tie, Qiongxian; Mao, Wei

    2000-10-01

    A control system of the vertical angle transmission used in the Lower Latitude Meridian Circle (LLMC) is described in this paper. The transmission system can change the zenith distance of the tube quickly and precisely. It works in three modes: fast motion, slow motion and lock mode. The fast motion mode and the slow motion mode are that the tube of the instrument is driven by a fast motion stepper motor and a slow motion one separately. The lock mode is running for lock mechanism that is driven by a lock stepper motor. These three motors are controlled together by a single chip microcontroller, which is controlled in turn by a host personal computer. The slow motion mechanism and its rotational step angle are fully discussed because the mechanism is not used before. Then the hardware structure of this control system based on a microcontroller is described. Control process of the system is introduced during a normal observation, which is divided into eleven steps. All the steps are programmed in our control software in C++ and/or in ASM. The C++ control program is set up in the host PC, while the ASM control program is in the microcontroller system. Structures and functions of these rprograms are presented. Some details and skills for programming are discussed in the paper too.

  13. The spinal posture of computing adolescents in a real-life setting

    PubMed Central

    2014-01-01

    Background It is assumed that good postural alignment is associated with the less likelihood of musculoskeletal pain symptoms. Encouraging good sitting postures have not reported consequent musculoskeletal pain reduction in school-based populations, possibly due to a lack of clear understanding of good posture. Therefore this paper describes the variability of postural angles in a cohort of asymptomatic high-school students whilst working on desk-top computers in a school computer classroom and to report on the relationship between the postural angles and age, gender, height, weight and computer use. Methods The baseline data from a 12 month longitudinal study is reported. The study was conducted in South African school computer classrooms. 194 Grade 10 high-school students, from randomly selected high-schools, aged 15–17 years, enrolled in Computer Application Technology for the first time, asymptomatic during the preceding month, and from whom written informed consent were obtained, participated in the study. The 3D Posture Analysis Tool captured five postural angles (head flexion, neck flexion, cranio-cervical angle, trunk flexion and head lateral bend) while the students were working on desk-top computers. Height, weight and computer use were also measured. Individual and combinations of postural angles were analysed. Results 944 Students were screened for eligibility of which the data of 194 students are reported. Trunk flexion was the most variable angle. Increased neck flexion and the combination of increased head flexion, neck flexion and trunk flexion were significantly associated with increased weight and BMI (p = 0.0001). Conclusions High-school students sit with greater ranges of trunk flexion (leaning forward or reclining) when using the classroom computer. Increased weight is significantly associated with increased sagittal plane postural angles. PMID:24950887

  14. A Home Computer Primer.

    ERIC Educational Resources Information Center

    Stone, Antonia

    1982-01-01

    Provides general information on currently available microcomputers, computer programs (software), hardware requirements, software sources, costs, computer games, and programing. Includes a list of popular microcomputers, providing price category, model, list price, software (cassette, tape, disk), monitor specifications, amount of random access…

  15. Comparison of improved range of motion between cam-type femoroacetabular impingement and borderline developmental dysplasia of the hip -evaluation by virtual osteochondroplasty using computer simulation.

    PubMed

    Kubota, So; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Tezuka, Taro; Saito, Tomoyuki

    2017-10-16

    While cam resection is essential to achieve a good clinical result with respect to femoroacetabular impingement (FAI), it is unclear whether it should also be performed in cases of borderline developmental dysplasia of the hip (DDH) with a cam deformity. The aim of this study was to evaluate improvements in range of motion (ROM) in cases of cam-type FAI and borderline DDH after virtual osteochondroplasty using a computer impingement simulation. Thirty-eight symptomatic hips in 31 patients (11male and 20 female) diagnosed with cam-type FAI or borderline DDH were analyzed. There were divided into a cam-type FAI group (cam-FAI group: 15 hips), borderline DDH without cam group (DDH W/O cam group: 12 hips), and borderline DDH with cam group (DDH W/ cam group: 11 hips). The bony impingement point on the femoral head-neck junction at 90° flexion and maximum internal rotation of the hip joint was identified using ZedHip® software. Virtual osteochondroplasty of the impingement point was then performed in all cases. The maximum flexion angle and maximum internal rotation angle at 90° flexion were measured before and after virtual osteochondroplasty at two resection ranges (i.e., slight and sufficient). The mean improvement in the internal rotation angle in the DDH W/ cam group after slight resection was significantly greater than that in the DDH W/O cam group (P = 0.046). Furthermore, the mean improvement in the internal rotation angle in the DDH W/ cam and cam-FAI groups after sufficient resection was significantly greater than that in the DDH W/O cam group (DDH W/ cam vs DDH W/O cam: P = 0.002, cam-FAI vs DDH W/O cam: P = 0.043). Virtual osteochondroplasty resulted in a significant improvement in internal rotation angle in DDH W/ cam group but not in DDH W/O cam group. Thus, borderline DDH cases with cam deformity may be better to consider performing osteochondroplasty.

  16. SU-F-J-53: A 3D Printed Phantom for the Use of Daily Quality Assurance Alignment Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woods, K; Ayan, A; Woollard, J

    Purpose: To discuss experiences and results for a 3D printed QA phantom used for daily alignment purposes for a six degrees-of-freedom (6DoF) table Methods: A 3D model was created using a fused deposition modeling (FDM) printer using free online computer-aided design (CAD) software. The model has been under use for daily QA alignment tests for a 6DoF couch. An aligned and angled baseplate were also printed in order to introduce known angles for 6DoF corrections during image-guidance. Unique registration contours were created on the faces of the phantom in order to achieve a better cone-beam computed tomography (CBCT) match usingmore » an auto-registration algorithm. A BB was also introduced at the center of the phantom in order to deliver an integrated daily Winston-Lutz (WL) test. Translational, rotational, and WL results were tabulated over one month. Results: The ’honeycomb’ structure of the print was apparent in the EPID images for the WL test, which affected the results of the analysis software. This was fixed by inserting a cube made of polyoxymethylene within the 3D phantom that encompass the BB. Auto-registration results for the three translational and three rotational from a known offset to the BB isocenter consistently fell within 1 mm and 0.2°, respectively. WL tests resulted in an average of 0.71 ± 0.14 mm. Conclusion: 3D printed models allow for accurate builds that can be customized to a variety of clinical needs. Results from translational, rotational, and WL show consistent results over a month’s time. Given its relatively cheap and streamlined workflow, 3D printing could be implemented into any clinic looking to create customized phantoms.« less

  17. Radiographic angles in hallux valgus: differences between measurements made manually and with a computerized program.

    PubMed

    Piqué-Vidal, Carlos; Maled-García, Ignaci; Arabi-Moreno, Juanjo; Vila, Joan

    2006-03-01

    The objective of this study was to compare angular measurements in the evaluation of hallux valgus deformities using a goniometer and a computerized program to assess degree of concordance between the two methods and determine the reliability of manual measurements. Angles measured included the hallux valgus angle (HVA), the intermetatarsal angle (IMA), the distal metatarsal articular angle (DMAA), and the proximal phalangeal articular angle (PPAA), also called the hallux valgus interphalangeus angle or interphalangeal angle. Measurements were made on preoperative weightbearing radiographs in 176 patients with symptomatic hallux valgus. Manual measurements were made with a goniometer by an orthopaedic surgeon. An independent experienced technician used digitized images to perform angular measurements with the Autocad software program (Autodesk Inc., San Rafael, CA). HVA values obtained with the two techniques were similar. However, significantly higher mean values were obtained with the Autocad for the IMA and PPAA measurements, and higher mean values were obtained for the DMAA measurement with the manual technique. Whereas differences were more or less randomly distributed for the HVA, in the remaining patients, measurements were clearly related to the measurement technique, i.e., for the DMAA, the manual technique had a tendency to show higher values, and for the IMA and PPAA the manual technique showed lower values than the computer. Correlations between both techniques for the different angular measurements were as follows: HVA, -0.179 (p = 0.018); DMMA, -0.294 (p < 0.001); PPAA, -0.876 (p < 0.001); and IMA, -0.661 (p < 0.001). The intraclass correlation coefficient (ICC) showed that the concordance between manual and Autocad angular measurements was excellent for the HVA (ICC = 0.89) and DMAA (ICC = 0.80) and very poor for the PPAA (ICC = 0.11) and IMA (ICC = 0.42). Angular measurements made on weightbearing radiographs with the Autocad in patients with hallux valgus deformities were more reliable than those made with a goniometer. Although for large angles, such as HVA and DMAA, results obtained with both measurement techniques were similar. Manual measurements, however, may underestimate the true values of the smaller IMA and PPAA angles.

  18. The Use of Computer Software to Teach High Technology Skills to Vocational Students.

    ERIC Educational Resources Information Center

    Farmer, Edgar I.

    A study examined the type of computer software that is best suited to teach high technology skills to vocational students. During the study, 50 manufacturers of computer software and hardware were sent questionnaires designed to gather data concerning their recommendations in regard to: software to teach high technology skills to vocational…

  19. 34 CFR 464.42 - What limit applies to purchasing computer hardware and software?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... software? 464.42 Section 464.42 Education Regulations of the Offices of the Department of Education... computer hardware and software? Not more than ten percent of funds received under any grant under this part may be used to purchase computer hardware or software. (Authority: 20 U.S.C. 1208aa(f)) ...

  20. 34 CFR 464.42 - What limit applies to purchasing computer hardware and software?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... software? 464.42 Section 464.42 Education Regulations of the Offices of the Department of Education... computer hardware and software? Not more than ten percent of funds received under any grant under this part may be used to purchase computer hardware or software. (Authority: 20 U.S.C. 1208aa(f)) ...

  1. 34 CFR 464.42 - What limit applies to purchasing computer hardware and software?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... software? 464.42 Section 464.42 Education Regulations of the Offices of the Department of Education... computer hardware and software? Not more than ten percent of funds received under any grant under this part may be used to purchase computer hardware or software. (Authority: 20 U.S.C. 1208aa(f)) ...

  2. 34 CFR 464.42 - What limit applies to purchasing computer hardware and software?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... software? 464.42 Section 464.42 Education Regulations of the Offices of the Department of Education... computer hardware and software? Not more than ten percent of funds received under any grant under this part may be used to purchase computer hardware or software. (Authority: 20 U.S.C. 1208aa(f)) ...

  3. 34 CFR 464.42 - What limit applies to purchasing computer hardware and software?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... software? 464.42 Section 464.42 Education Regulations of the Offices of the Department of Education... computer hardware and software? Not more than ten percent of funds received under any grant under this part may be used to purchase computer hardware or software. (Authority: 20 U.S.C. 1208aa(f)) ...

  4. Copyright Protection for Computer Software: Is There a Need for More Protection?

    ERIC Educational Resources Information Center

    Ku, Linlin

    Because the computer industry's expansion has been much faster than has the development of laws protecting computer software and since the practice of software piracy seems to be alive and well, the issue of whether existing laws can provide effective protection for software needs further discussion. Three bodies of law have been used to protect…

  5. Development of simulation computer complex specification

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The Training Simulation Computer Complex Study was one of three studies contracted in support of preparations for procurement of a shuttle mission simulator for shuttle crew training. The subject study was concerned with definition of the software loads to be imposed on the computer complex to be associated with the shuttle mission simulator and the development of procurement specifications based on the resulting computer requirements. These procurement specifications cover the computer hardware and system software as well as the data conversion equipment required to interface the computer to the simulator hardware. The development of the necessary hardware and software specifications required the execution of a number of related tasks which included, (1) simulation software sizing, (2) computer requirements definition, (3) data conversion equipment requirements definition, (4) system software requirements definition, (5) a simulation management plan, (6) a background survey, and (7) preparation of the specifications.

  6. Bioinspired Surface Treatments for Improved Decontamination: Icephobic Surfaces

    DTIC Science & Technology

    2017-06-26

    standing droplets of water (left) and methyl salicylate (right) immediately following liquid application (top) and 5 min after liquid application...average of nine measurements for each liquid ). Geometric surface energy was calculated based on the water and ethylene glycol interactions using software...supporting platform angle was gradually increased up to 60°. Sliding angles for each of the liquids were identified as the angle for which movement

  7. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Baggs, Rhoda

    2007-01-01

    Safety-critical computer systems must be engineered to meet system and software safety requirements. For legacy safety-critical computer systems, software safety requirements may not have been formally specified during development. When process-oriented software safety requirements are levied on a legacy system after the fact, where software development artifacts don't exist or are incomplete, the question becomes 'how can this be done?' The risks associated with only meeting certain software safety requirements in a legacy safety-critical computer system must be addressed should such systems be selected as candidates for reuse. This paper proposes a method for ascertaining formally, a software safety risk assessment, that provides measurements for software safety for legacy systems which may or may not have a suite of software engineering documentation that is now normally required. It relies upon the NASA Software Safety Standard, risk assessment methods based upon the Taxonomy-Based Questionnaire, and the application of reverse engineering CASE tools to produce original design documents for legacy systems.

  8. Analyses and Comparison of Solar Air Heater with Various Rib Roughness using Computational Fluid Dynamics (CFD)

    NASA Astrophysics Data System (ADS)

    Kumar, K. Ravi; Cheepu, Muralimohan; Srinivas, B.; Venkateswarlu, D.; Pramod Kumar, G.; Shiva, Apireddi

    2018-03-01

    In solar air heater, artificial roughness on absorber plate become prominent technique to improving heat transfer rate of air flowing passage as a result of laminar sublayer. The selection of rib geometries plays important role on friction characteristics and heat transfer rate. Many researchers studying the roughness shapes over the years to investigate the effect of geometries on the performance of friction factor and heat transfer of the solar air heater. The present study made an attempt to develop the different rib shapes utilised for creating artificial rib roughness and its comparison to investigate higher performance of the geometries. The use of computational fluid dynamics software resulted in correlation of friction factor and heat transfer rate. The simulations studies were performed on 2D computational fluid dynamics model and analysed to identify the most effective parameters of relative roughness of the height, width and pitch on major considerations of friction factor and heat transfer. The Reynolds number is varied in a range from 3000 to 20000, in the current study and modelling has conducted on heat transfer and turbulence phenomena by using Reynolds number. The modelling results showed the formation of strong vortex in the main stream flow due to the right angle triangle roughness over the square, rectangle, improved rectangle and equilateral triangle geometries enhanced the heat transfer extension in the solar air heater. The simulation of the turbulence kinetic energy of the geometry suggests the local turbulence kinetic energy has been influenced strongly by the alignments of the right angle triangle.

  9. Product development: using a 3D computer model to optimize the stability of the Rocket powered wheelchair.

    PubMed

    Pinkney, S; Fernie, G

    2001-01-01

    A three-dimensional (3D) lumped-parameter model of a powered wheelchair was created to aid the development of the Rocket prototype wheelchair and to help explore the effect of innovative design features on its stability. The model was developed using simulation software, specifically Working Model 3D. The accuracy of the model was determined by comparing both its static stability angles and dynamic behavior as it passed down a 4.8-cm (1.9") road curb at a heading of 45 degrees with the performance of the actual wheelchair. The model's predictions of the static stability angles in the forward, rearward, and lateral directions were within 9.3, 7.1, and 3.8% of the measured values, respectively. The average absolute error in the predicted position of the wheelchair as it moved down the curb was 2.2 cm/m (0.9" per 3'3") traveled. The accuracy was limited by the inability to model soft bodies, the inherent difficulties in modeling a statically indeterminate system, and the computing time. Nevertheless, it was found to be useful in investigating the effect of eight design alterations on the lateral stability of the wheelchair. Stability was quantified by determining the static lateral stability angles and the maximum height of a road curb over which the wheelchair could successfully drive on a diagonal heading. The model predicted that the stability was more dependent on the configuration of the suspension system than on the dimensions and weight distribution of the wheelchair. Furthermore, for the situations and design alterations studied, predicted improvements in static stability were not correlated with improvements in dynamic stability.

  10. Computational fluid dynamics (CFD) simulation of a newly designed passive particle sampler.

    PubMed

    Sajjadi, H; Tavakoli, B; Ahmadi, G; Dhaniyala, S; Harner, T; Holsen, T M

    2016-07-01

    In this work a series of computational fluid dynamics (CFD) simulations were performed to predict the deposition of particles on a newly designed passive dry deposition (Pas-DD) sampler. The sampler uses a parallel plate design and a conventional polyurethane foam (PUF) disk as the deposition surface. The deposition of particles with sizes between 0.5 and 10 μm was investigated for two different geometries of the Pas-DD sampler for different wind speeds and various angles of attack. To evaluate the mean flow field, the k-ɛ turbulence model was used and turbulent fluctuating velocities were generated using the discrete random walk (DRW) model. The CFD software ANSYS-FLUENT was used for performing the numerical simulations. It was found that the deposition velocity increased with particle size or wind speed. The modeled deposition velocities were in general agreement with the experimental measurements and they increased when flow entered the sampler with a non-zero angle of attack. The particle-size dependent deposition velocity was also dependent on the geometry of the leading edge of the sampler; deposition velocities were more dependent on particle size and wind speeds for the sampler without the bend in the leading edge of the deposition plate, compared to a flat plate design. Foam roughness was also found to have a small impact on particle deposition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. 48 CFR 227.7201 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7201 Definitions. (a) As used in this subpart, unless... subpart are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and...

  12. 48 CFR 227.7201 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7201 Definitions. (a) As used in this subpart, unless... subpart are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and...

  13. 48 CFR 227.7201 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7201 Definitions. (a) As used in this subpart, unless... subpart are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and...

  14. 48 CFR 227.7201 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7201 Definitions. (a) As used in this subpart, unless... subpart are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and...

  15. 48 CFR 227.7201 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF DEFENSE GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Computer Software and Computer Software Documentation 227.7201 Definitions. (a) As used in this subpart, unless... subpart are defined in the clause at 252.227-7014, Rights in Noncommercial Computer Software and...

  16. 29 CFR 541.401 - Computer manufacture and repair.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., the use of computers and computer software programs (e.g., engineers, drafters and others skilled in computer-aided design software), but who are not primarily engaged in computer systems analysis and...

  17. 29 CFR 541.401 - Computer manufacture and repair.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., the use of computers and computer software programs (e.g., engineers, drafters and others skilled in computer-aided design software), but who are not primarily engaged in computer systems analysis and...

  18. 29 CFR 541.401 - Computer manufacture and repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., the use of computers and computer software programs (e.g., engineers, drafters and others skilled in computer-aided design software), but who are not primarily engaged in computer systems analysis and...

  19. 29 CFR 541.401 - Computer manufacture and repair.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., the use of computers and computer software programs (e.g., engineers, drafters and others skilled in computer-aided design software), but who are not primarily engaged in computer systems analysis and...

  20. Architecture independent environment for developing engineering software on MIMD computers

    NASA Technical Reports Server (NTRS)

    Valimohamed, Karim A.; Lopez, L. A.

    1990-01-01

    Engineers are constantly faced with solving problems of increasing complexity and detail. Multiple Instruction stream Multiple Data stream (MIMD) computers have been developed to overcome the performance limitations of serial computers. The hardware architectures of MIMD computers vary considerably and are much more sophisticated than serial computers. Developing large scale software for a variety of MIMD computers is difficult and expensive. There is a need to provide tools that facilitate programming these machines. First, the issues that must be considered to develop those tools are examined. The two main areas of concern were architecture independence and data management. Architecture independent software facilitates software portability and improves the longevity and utility of the software product. It provides some form of insurance for the investment of time and effort that goes into developing the software. The management of data is a crucial aspect of solving large engineering problems. It must be considered in light of the new hardware organizations that are available. Second, the functional design and implementation of a software environment that facilitates developing architecture independent software for large engineering applications are described. The topics of discussion include: a description of the model that supports the development of architecture independent software; identifying and exploiting concurrency within the application program; data coherence; engineering data base and memory management.

  1. Small-College Software Survey.

    ERIC Educational Resources Information Center

    Birch, Anthony D.

    1986-01-01

    Computers have a great number of potential uses at the small college. A survey of the role of software in the effective use of computers is described. Hardware characteristics, spreadsheets, purchasing or developing software, and software information are discussed. (Author/MLW)

  2. Software engineering methodologies and tools

    NASA Technical Reports Server (NTRS)

    Wilcox, Lawrence M.

    1993-01-01

    Over the years many engineering disciplines have developed, including chemical, electronic, etc. Common to all engineering disciplines is the use of rigor, models, metrics, and predefined methodologies. Recently, a new engineering discipline has appeared on the scene, called software engineering. For over thirty years computer software has been developed and the track record has not been good. Software development projects often miss schedules, are over budget, do not give the user what is wanted, and produce defects. One estimate is there are one to three defects per 1000 lines of deployed code. More and more systems are requiring larger and more complex software for support. As this requirement grows, the software development problems grow exponentially. It is believed that software quality can be improved by applying engineering principles. Another compelling reason to bring the engineering disciplines to software development is productivity. It has been estimated that productivity of producing software has only increased one to two percent a year in the last thirty years. Ironically, the computer and its software have contributed significantly to the industry-wide productivity, but computer professionals have done a poor job of using the computer to do their job. Engineering disciplines and methodologies are now emerging supported by software tools that address the problems of software development. This paper addresses some of the current software engineering methodologies as a backdrop for the general evaluation of computer assisted software engineering (CASE) tools from actual installation of and experimentation with some specific tools.

  3. Ground Software Maintenance Facility (GSMF) system manual

    NASA Technical Reports Server (NTRS)

    Derrig, D.; Griffith, G.

    1986-01-01

    The Ground Software Maintenance Facility (GSMF) is designed to support development and maintenance of spacelab ground support software. THE GSMF consists of a Perkin Elmer 3250 (Host computer) and a MITRA 125s (ATE computer), with appropriate interface devices and software to simulate the Electrical Ground Support Equipment (EGSE). This document is presented in three sections: (1) GSMF Overview; (2) Software Structure; and (3) Fault Isolation Capability. The overview contains information on hardware and software organization along with their corresponding block diagrams. The Software Structure section describes the modes of software structure including source files, link information, and database files. The Fault Isolation section describes the capabilities of the Ground Computer Interface Device, Perkin Elmer host, and MITRA ATE.

  4. Animation of multi-flexible body systems and its use in control system design

    NASA Technical Reports Server (NTRS)

    Juengst, Carl; Stahlberg, Ron

    1993-01-01

    Animation can greatly assist the structural dynamicist and control system analyst with better understanding of how multi-flexible body systems behave. For multi-flexible body systems, the structural characteristics (mode frequencies, mode shapes, and damping) change, sometimes dramatically with large angles of rotation between bodies. With computer animation, the analyst can visualize these changes and how the system responds to active control forces and torques. A characterization of the type of system we wish to animate is presented. The lack of clear understanding of the above effects was a key element leading to the development of a multi-flexible body animation software package. The resulting animation software is described in some detail here, followed by its application to the control system analyst. Other applications of this software can be determined on an individual need basis. A number of software products are currently available that make the high-speed rendering of rigid body mechanical system simulation possible. However, such options are not available for use in rendering flexible body mechanical system simulations. The desire for a high-speed flexible body visualization tool led to the development of the Flexible Or Rigid Mechanical System (FORMS) software. This software was developed at the Center for Simulation and Design Optimization of Mechanical Systems at the University of Iowa. FORMS provides interactive high-speed rendering of flexible and/or rigid body mechanical system simulations, and combines geometry and motion information to produce animated output. FORMS is designed to be both portable and flexible, and supports a number of different user interfaces and graphical display devices. Additional features have been added to FORMS that allow special visualization results related to the nature of the flexible body geometric representations.

  5. 77 FR 32996 - Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-769] Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof; Termination of the Investigation Based on... electronic computing devices, related software, and components thereof by reason of infringement of certain...

  6. 48 CFR 227.7207 - Contractor data repositories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... repositories. 227.7207 Section 227.7207 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS... Computer Software and Computer Software Documentation 227.7207 Contractor data repositories. Follow 227.7108 when it is in the Government's interests to have a data repository include computer software or to...

  7. Cloud Computing: A Free Technology Option to Promote Collaborative Learning

    ERIC Educational Resources Information Center

    Siegle, Del

    2010-01-01

    In a time of budget cuts and limited funding, purchasing and installing the latest software on classroom computers can be prohibitive for schools. Many educators are unaware that a variety of free software options exist, and some of them do not actually require installing software on the user's computer. One such option is cloud computing. This…

  8. 78 FR 47015 - Software Requirement Specifications for Digital Computer Software Used in Safety Systems of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Requirement Specifications for Digital Computer Software Used in Safety Systems of Nuclear Power Plants AGENCY: Nuclear Regulatory Commission... issuing a revised regulatory guide (RG), revision 1 of RG 1.172, ``Software Requirement Specifications for...

  9. Investigating the structure of a vortex flow in the closed polygonal containers

    NASA Astrophysics Data System (ADS)

    Podolskaya, I. Yu; Bakakin, G. V.; Naumov, I. V.

    2018-03-01

    The structure of confined vortex flow generated by a rotating lid in a closed container with polygonal cross-section geometry (eight, six and five angles) has been investigated numerically for different height/radius aspect ratios h from 3.0 to 4.5 and for Reynold numbers ranging from 1500 to 3000. The critical Reynolds numbers at which the flow becomes unsteady were determined numerically by STAR-CCM+ computational fluid dynamics software for pentagonal and hexagonal cross-section configurations. The obtained results were compared with the flow structure in the closed cylindrical container. The boundary of a nonstationarity in polygonal containers is found to shift to the region of smaller aspect ratio and smaller Reynolds numbers with a decrease in the number of angles in the cross-section of the container relative to the boundary in a cylindrical container. It is additionally established that the structure of the flow in the near-axis region remains similar to the vortex structure in the cylinder, therefore the shape of the container does not influence the near-axis region.

  10. Study of scattering from turbulence structure generated by propeller with FLUENT

    NASA Astrophysics Data System (ADS)

    Luo, Gen

    2017-07-01

    In this article, the turbulence structure generated by a propeller is simulated with the computational fluid dynamics (CFD) software FLUENT. With the method of moments, the backscattering radar cross sections (RCS) of the turbulence structure are calculated. The scattering results can reflect the turbulent intensity of the wave profiles. For the wake turbulence with low rotating speed, the scattering intensity of HH polarization is much smaller than VV polarization at large incident angles. When the turbulence becomes stronger with high rotating speed, the scattering intensity of HH polarization also becomes stronger at large incident angles, which is almost the same with VV polarization. And also, the bistatic scattering of the turbulence structure has the similar situation. These scattering results indicate that the turbulence structure can also give rise to an anomaly compared with traditional sea surface. The study of electromagnetic (EM) scattering from turbulence structure generated by the propeller can help in better understanding of the scattering from different kinds of waves and provide more bases to explain the anomalies of EM scattering from sea surfaces.

  11. Consistency of flow quantifications in tridirectional phase-contrast MRI

    NASA Astrophysics Data System (ADS)

    Unterhinninghofen, R.; Ley, S.; Dillmann, R.

    2009-02-01

    Tridirectionally encoded phase-contrast MRI is a technique to non-invasively acquire time-resolved velocity vector fields of blood flow. These may not only be used to analyze pathological flow patterns, but also to quantify flow at arbitrary positions within the acquired volume. In this paper we examine the validity of this approach by analyzing the consistency of related quantifications instead of comparing it with an external reference measurement. Datasets of the thoracic aorta were acquired from 6 pigs, 1 healthy volunteer and 3 patients with artificial aortic valves. Using in-house software an elliptical flow quantification plane was placed manually at 6 positions along the descending aorta where it was rotated to 5 different angles. For each configuration flow was computed based on the original data and data that had been corrected for phase offsets. Results reveal that quantifications are more dependent on changes in position than on changes in angle. Phase offset correction considerably reduces this dependency. Overall consistency is good with a maximum variation coefficient of 9.9% and a mean variation coefficient of 7.2%.

  12. Parallel computers - Estimate errors caused by imprecise data

    NASA Technical Reports Server (NTRS)

    Kreinovich, Vladik; Bernat, Andrew; Villa, Elsa; Mariscal, Yvonne

    1991-01-01

    A new approach to the problem of estimating errors caused by imprecise data is proposed in the context of software engineering. A software device is used to produce an ideal solution to the problem, when the computer is capable of computing errors of arbitrary programs. The software engineering aspect of this problem is to describe a device for computing the error estimates in software terms and then to provide precise numbers with error estimates to the user. The feasibility of the program capable of computing both some quantity and its error estimate in the range of possible measurement errors is demonstrated.

  13. Gravitational tree-code on graphics processing units: implementation in CUDA

    NASA Astrophysics Data System (ADS)

    Gaburov, Evghenii; Bédorf, Jeroen; Portegies Zwart, Simon

    2010-05-01

    We present a new very fast tree-code which runs on massively parallel Graphical Processing Units (GPU) with NVIDIA CUDA architecture. The tree-construction and calculation of multipole moments is carried out on the host CPU, while the force calculation which consists of tree walks and evaluation of interaction list is carried out on the GPU. In this way we achieve a sustained performance of about 100GFLOP/s and data transfer rates of about 50GB/s. It takes about a second to compute forces on a million particles with an opening angle of θ ≈ 0.5. The code has a convenient user interface and is freely available for use. http://castle.strw.leidenuniv.nl/software/octgrav.html

  14. Real time 3D scanner: investigations and results

    NASA Astrophysics Data System (ADS)

    Nouri, Taoufik; Pflug, Leopold

    1993-12-01

    This article presents a concept of reconstruction of 3-D objects using non-invasive and touch loss techniques. The principle of this method is to display parallel interference optical fringes on an object and then to record the object under two angles of view. According to an appropriated treatment one reconstructs the 3-D object even when the object has no symmetrical plan. The 3-D surface data is available immediately in digital form for computer- visualization and for analysis software tools. The optical set-up for recording the 3-D object, the 3-D data extraction and treatment, as well as the reconstruction of the 3-D object are reported and commented on. This application is dedicated for reconstructive/cosmetic surgery, CAD, animation and research purposes.

  15. Open-Source Software in Computational Research: A Case Study

    DOE PAGES

    Syamlal, Madhava; O'Brien, Thomas J.; Benyahia, Sofiane; ...

    2008-01-01

    A case study of open-source (OS) development of the computational research software MFIX, used for multiphase computational fluid dynamics simulations, is presented here. The verification and validation steps required for constructing modern computational software and the advantages of OS development in those steps are discussed. The infrastructure used for enabling the OS development of MFIX is described. The impact of OS development on computational research and education in gas-solids flow, as well as the dissemination of information to other areas such as geophysical and volcanology research, is demonstrated. This study shows that the advantages of OS development were realized inmore » the case of MFIX: verification by many users, which enhances software quality; the use of software as a means for accumulating and exchanging information; the facilitation of peer review of the results of computational research.« less

  16. Reliability of computer-assisted periacetabular osteotomy using a minimally invasive approach.

    PubMed

    De Raedt, Sepp; Mechlenburg, Inger; Stilling, Maiken; Rømer, Lone; Murphy, Ryan J; Armand, Mehran; Lepistö, Jyri; de Bruijne, Marleen; Søballe, Kjeld

    2018-06-06

    Periacetabular osteotomy (PAO) is the treatment of choice for younger patients with developmental hip dysplasia. The procedure aims to normalize the joint configuration, reduce the peak-pressure, and delay the development of osteoarthritis. The procedure is technically demanding and no previous study has validated the use of computer navigation with a minimally invasive transsartorial approach. Computer-assisted PAO was performed on ten patients. Patients underwent pre- and postoperative computed tomography (CT) scanning with a standardized protocol. Preoperative preparation consisted of outlining the lunate surface and segmenting the pelvis and femur from CT data. The Biomechanical Guidance System was used intra-operatively to automatically calculate diagnostic angles and peak-pressure measurements. Manual diagnostic angle measurements were performed based on pre- and postoperative CT. Differences in angle measurements were investigated with summary statistics, intraclass correlation coefficient, and Bland-Altman plots. The percentage postoperative change in peak-pressure was calculated. Intra-operative reported angle measurements show a good agreement with manual angle measurements with intraclass correlation coefficient between 0.94 and 0.98. Computer navigation reported angle measurements were significantly higher for the posterior sector angle ([Formula: see text], [Formula: see text]) and the acetabular anteversion angle ([Formula: see text], [Formula: see text]). No significant difference was found for the center-edge ([Formula: see text]), acetabular index ([Formula: see text]), and anterior sector angle ([Formula: see text]). Peak-pressure after PAO decreased by a mean of 13% and was significantly different ([Formula: see text]). We found that computer navigation can reliably be used with a minimally invasive transsartorial approach PAO. Angle measurements generally agree with manual measurements and peak-pressure was shown to decrease postoperatively. With further development, the system will become a valuable tool in the operating room for both experienced and less experienced surgeons performing PAO. Further studies with a larger cohort and follow-up will allow us to investigate the association with peak-pressure and postoperative outcome and pave the way to clinical introduction.

  17. Computer Software & Intellectual Property. Background Paper.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Office of Technology Assessment.

    This background paper reviews copyright, patent, and trade secret protections as these issues are related to computer software. Topics discussed include current issues regarding legal protection for computer software including the necessity for defining intellectual property, determining what should or should not be protected, commerical piracy,…

  18. Computer Software Reviews.

    ERIC Educational Resources Information Center

    Hawaii State Dept. of Education, Honolulu. Office of Instructional Services.

    Intended to provide guidance in the selection of the best computer software available to support instruction and to make optimal use of schools' financial resources, this publication provides a listing of computer software programs that have been evaluated according to their currency, relevance, and value to Hawaii's educational programs. The…

  19. High Energy Physics Forum for Computational Excellence: Working Group Reports (I. Applications Software II. Software Libraries and Tools III. Systems)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habib, Salman; Roser, Robert

    Computing plays an essential role in all aspects of high energy physics. As computational technology evolves rapidly in new directions, and data throughput and volume continue to follow a steep trend-line, it is important for the HEP community to develop an effective response to a series of expected challenges. In order to help shape the desired response, the HEP Forum for Computational Excellence (HEP-FCE) initiated a roadmap planning activity with two key overlapping drivers -- 1) software effectiveness, and 2) infrastructure and expertise advancement. The HEP-FCE formed three working groups, 1) Applications Software, 2) Software Libraries and Tools, and 3)more » Systems (including systems software), to provide an overview of the current status of HEP computing and to present findings and opportunities for the desired HEP computational roadmap. The final versions of the reports are combined in this document, and are presented along with introductory material.« less

  20. High Energy Physics Forum for Computational Excellence: Working Group Reports (I. Applications Software II. Software Libraries and Tools III. Systems)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habib, Salman; Roser, Robert; LeCompte, Tom

    2015-10-29

    Computing plays an essential role in all aspects of high energy physics. As computational technology evolves rapidly in new directions, and data throughput and volume continue to follow a steep trend-line, it is important for the HEP community to develop an effective response to a series of expected challenges. In order to help shape the desired response, the HEP Forum for Computational Excellence (HEP-FCE) initiated a roadmap planning activity with two key overlapping drivers -- 1) software effectiveness, and 2) infrastructure and expertise advancement. The HEP-FCE formed three working groups, 1) Applications Software, 2) Software Libraries and Tools, and 3)more » Systems (including systems software), to provide an overview of the current status of HEP computing and to present findings and opportunities for the desired HEP computational roadmap. The final versions of the reports are combined in this document, and are presented along with introductory material.« less

  1. Paradigm of Legal Protection of Computer Software Contracts in the United States: Brief Overview of “Principles of the Law of Software Contracts”

    NASA Astrophysics Data System (ADS)

    Furuya, Haruhisa; Hiratsuka, Mitsuyoshi

    This article overviews the historical transition of legal protection of Computer software contracts in the Unite States and presents how it should function under Uniform Commercial Code and its amended Article 2B, Uniform Computer Information Transactions Act, and also recently-approved “Principles of the Law of Software Contracts”.

  2. Computational measurement of joint space width and structural parameters in normal hips.

    PubMed

    Nishii, Takashi; Shiomi, Toshiyuki; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-05-01

    Joint space width (JSW) of hip joints on radiographs in normal population may vary by related factors, but previous investigations were insufficient due to limitations of sources of radiographs, inclusion of subjects with osteoarthritis, and manual measurement techniques. We investigated influential factors on JSW using semiautomatic computational software on pelvic radiographs in asymptomatic subjects without radiological osteoarthritic findings. Global and local JSW at the medial, middle, and lateral compartments, and the hip structural parameters were measured in asymptomatic, normal 150 cases (300 hips), using a customized computational software. Reliability of measurement in global and local JSWs was high with intraobserver reproducibility (intraclass correlation coefficient) ranging from 0.957 to 0.993 and interobserver reproducibility ranging from 0.925 to 0.985. There were significant differences among three local JSWs, with the largest JSW at the lateral compartment. Global and medial local JSWs were significantly larger in the right hip, and global, medial and middle local JSWs were significantly smaller in women. Global and local JSWs were inversely correlated with CE angle and positively correlated with horizontal distance of the head center, but not correlated with body mass index in men and women. They were positively correlated with age and inversely correlated with vertical distance of the head center only in men. There were interindividual variations of JSW in normal population, depending on sites of the weight-bearing area, side, gender, age, and hip structural parameters. For accurate diagnosis and assessment of hip osteoarthritis, consideration of those influential factors other than degenerative change is important.

  3. Fault-tolerant software - Experiment with the sift operating system. [Software Implemented Fault Tolerance computer

    NASA Technical Reports Server (NTRS)

    Brunelle, J. E.; Eckhardt, D. E., Jr.

    1985-01-01

    Results are presented of an experiment conducted in the NASA Avionics Integrated Research Laboratory (AIRLAB) to investigate the implementation of fault-tolerant software techniques on fault-tolerant computer architectures, in particular the Software Implemented Fault Tolerance (SIFT) computer. The N-version programming and recovery block techniques were implemented on a portion of the SIFT operating system. The results indicate that, to effectively implement fault-tolerant software design techniques, system requirements will be impacted and suggest that retrofitting fault-tolerant software on existing designs will be inefficient and may require system modification.

  4. Software Issues at the User Interface

    DTIC Science & Technology

    1991-05-01

    successful integration of parallel computers into mainstream scientific computing. Clearly a compiler is the most important software tool available to a...Computer Science University of Colorado Boulder, CO 80309 ABSTRACT We review software issues that are critical to the successful integration of parallel...The development of an optimizing compiler of this quality, addressing communicaton instructions as well as computational instructions is a major

  5. Using satellite communications for a mobile computer network

    NASA Technical Reports Server (NTRS)

    Wyman, Douglas J.

    1993-01-01

    The topics discussed include the following: patrol car automation, mobile computer network, network requirements, network design overview, MCN mobile network software, MCN hub operation, mobile satellite software, hub satellite software, the benefits of patrol car automation, the benefits of satellite mobile computing, and national law enforcement satellite.

  6. 48 CFR 1852.227-19 - Commercial computer software-Restricted rights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... software-Restricted rights. 1852.227-19 Section 1852.227-19 Federal Acquisition Regulations System NATIONAL... Provisions and Clauses 1852.227-19 Commercial computer software—Restricted rights. (a) As prescribed in 1827... regarding any computer software delivered under this contract/purchase order, the NASA Contracting Officer...

  7. 48 CFR 1852.227-19 - Commercial computer software-Restricted rights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... software-Restricted rights. 1852.227-19 Section 1852.227-19 Federal Acquisition Regulations System NATIONAL... Provisions and Clauses 1852.227-19 Commercial computer software—Restricted rights. (a) As prescribed in 1827... regarding any computer software delivered under this contract/purchase order, the NASA Contracting Officer...

  8. 48 CFR 1852.227-19 - Commercial computer software-Restricted rights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... software-Restricted rights. 1852.227-19 Section 1852.227-19 Federal Acquisition Regulations System NATIONAL... Provisions and Clauses 1852.227-19 Commercial computer software—Restricted rights. (a) As prescribed in 1827... regarding any computer software delivered under this contract/purchase order, the NASA Contracting Officer...

  9. 48 CFR 1852.227-19 - Commercial computer software-Restricted rights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... software-Restricted rights. 1852.227-19 Section 1852.227-19 Federal Acquisition Regulations System NATIONAL... Provisions and Clauses 1852.227-19 Commercial computer software—Restricted rights. (a) As prescribed in 1827... regarding any computer software delivered under this contract/purchase order, the NASA Contracting Officer...

  10. 48 CFR 1852.227-19 - Commercial computer software-Restricted rights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... software-Restricted rights. 1852.227-19 Section 1852.227-19 Federal Acquisition Regulations System NATIONAL... Provisions and Clauses 1852.227-19 Commercial computer software—Restricted rights. (a) As prescribed in 1827... regarding any computer software delivered under this contract/purchase order, the NASA Contracting Officer...

  11. Computer and control applications in a vegetable processing plant

    USDA-ARS?s Scientific Manuscript database

    There are many advantages to the use of computers and control in food industry. Software in the food industry takes 2 forms - general purpose commercial computer software and software for specialized applications, such as drying and thermal processing of foods. Many applied simulation models for d...

  12. IUWare and Computing Tools: Indiana University's Approach to Low-Cost Software.

    ERIC Educational Resources Information Center

    Sheehan, Mark C.; Williams, James G.

    1987-01-01

    Describes strategies for providing low-cost microcomputer-based software for classroom use on college campuses. Highlights include descriptions of the software (IUWare and Computing Tools); computing center support; license policies; documentation; promotion; distribution; staff, faculty, and user training; problems; and future plans. (LRW)

  13. 48 CFR 227.7103-7 - Use and non-disclosure agreement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... release, disclosure, or authorized use of technical data or computer software subject to special license... (b) of this subsection, technical data or computer software delivered to the Government with..., display, or disclose technical data subject to limited rights or computer software subject to restricted...

  14. 29 CFR 541.401 - Computer manufacture and repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DEFINING AND DELIMITING THE EXEMPTIONS FOR EXECUTIVE, ADMINISTRATIVE, PROFESSIONAL, COMPUTER AND OUTSIDE..., the use of computers and computer software programs (e.g., engineers, drafters and others skilled in computer-aided design software), but who are not primarily engaged in computer systems analysis and...

  15. [Measurement of intracranial hematoma volume by personal computer].

    PubMed

    DU, Wanping; Tan, Lihua; Zhai, Ning; Zhou, Shunke; Wang, Rui; Xue, Gongshi; Xiao, An

    2011-01-01

    To explore the method for intracranial hematoma volume measurement by the personal computer. Forty cases of various intracranial hematomas were measured by the computer tomography with quantitative software and personal computer with Photoshop CS3 software, respectively. the data from the 2 methods were analyzed and compared. There was no difference between the data from the computer tomography and the personal computer (P>0.05). The personal computer with Photoshop CS3 software can measure the volume of various intracranial hematomas precisely, rapidly and simply. It should be recommended in the clinical medicolegal identification.

  16. Synchronizing Photography For High-Speed-Engine Research

    NASA Technical Reports Server (NTRS)

    Chun, K. S.

    1989-01-01

    Light flashes when shaft reaches predetermined angle. Synchronization system facilitates visualization of flow in high-speed internal-combustion engines. Designed for cinematography and holographic interferometry, system synchronizes camera and light source with predetermined rotational angle of engine shaft. 10-bit resolution of absolute optical shaft encoder adapted, and 2 to tenth power combinations of 10-bit binary data computed to corresponding angle values. Pre-computed angle values programmed into EPROM's (erasable programmable read-only memories) to use as angle lookup table. Resolves shaft angle to within 0.35 degree at rotational speeds up to 73,240 revolutions per minute.

  17. Bringing Legacy Visualization Software to Modern Computing Devices via Application Streaming

    NASA Astrophysics Data System (ADS)

    Fisher, Ward

    2014-05-01

    Planning software compatibility across forthcoming generations of computing platforms is a problem commonly encountered in software engineering and development. While this problem can affect any class of software, data analysis and visualization programs are particularly vulnerable. This is due in part to their inherent dependency on specialized hardware and computing environments. A number of strategies and tools have been designed to aid software engineers with this task. While generally embraced by developers at 'traditional' software companies, these methodologies are often dismissed by the scientific software community as unwieldy, inefficient and unnecessary. As a result, many important and storied scientific software packages can struggle to adapt to a new computing environment; for example, one in which much work is carried out on sub-laptop devices (such as tablets and smartphones). Rewriting these packages for a new platform often requires significant investment in terms of development time and developer expertise. In many cases, porting older software to modern devices is neither practical nor possible. As a result, replacement software must be developed from scratch, wasting resources better spent on other projects. Enabled largely by the rapid rise and adoption of cloud computing platforms, 'Application Streaming' technologies allow legacy visualization and analysis software to be operated wholly from a client device (be it laptop, tablet or smartphone) while retaining full functionality and interactivity. It mitigates much of the developer effort required by other more traditional methods while simultaneously reducing the time it takes to bring the software to a new platform. This work will provide an overview of Application Streaming and how it compares against other technologies which allow scientific visualization software to be executed from a remote computer. We will discuss the functionality and limitations of existing application streaming frameworks and how a developer might prepare their software for application streaming. We will also examine the secondary benefits realized by moving legacy software to the cloud. Finally, we will examine the process by which a legacy Java application, the Integrated Data Viewer (IDV), is to be adapted for tablet computing via Application Streaming.

  18. NMRbox: A Resource for Biomolecular NMR Computation.

    PubMed

    Maciejewski, Mark W; Schuyler, Adam D; Gryk, Michael R; Moraru, Ion I; Romero, Pedro R; Ulrich, Eldon L; Eghbalnia, Hamid R; Livny, Miron; Delaglio, Frank; Hoch, Jeffrey C

    2017-04-25

    Advances in computation have been enabling many recent advances in biomolecular applications of NMR. Due to the wide diversity of applications of NMR, the number and variety of software packages for processing and analyzing NMR data is quite large, with labs relying on dozens, if not hundreds of software packages. Discovery, acquisition, installation, and maintenance of all these packages is a burdensome task. Because the majority of software packages originate in academic labs, persistence of the software is compromised when developers graduate, funding ceases, or investigators turn to other projects. To simplify access to and use of biomolecular NMR software, foster persistence, and enhance reproducibility of computational workflows, we have developed NMRbox, a shared resource for NMR software and computation. NMRbox employs virtualization to provide a comprehensive software environment preconfigured with hundreds of software packages, available as a downloadable virtual machine or as a Platform-as-a-Service supported by a dedicated compute cloud. Ongoing development includes a metadata harvester to regularize, annotate, and preserve workflows and facilitate and enhance data depositions to BioMagResBank, and tools for Bayesian inference to enhance the robustness and extensibility of computational analyses. In addition to facilitating use and preservation of the rich and dynamic software environment for biomolecular NMR, NMRbox fosters the development and deployment of a new class of metasoftware packages. NMRbox is freely available to not-for-profit users. Copyright © 2017 Biophysical Society. All rights reserved.

  19. TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutti, V; Morrow, A; Kim, S

    Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatmentmore » isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.« less

  20. Software for Real-Time Analysis of Subsonic Test Shot Accuracy

    DTIC Science & Technology

    2014-03-01

    used the C++ programming language, the Open Source Computer Vision ( OpenCV ®) software library, and Microsoft Windows® Application Programming...video for comparison through OpenCV image analysis tools. Based on the comparison, the software then computed the coordinates of each shot relative to...DWB researchers wanted to use the Open Source Computer Vision ( OpenCV ) software library for capturing and analyzing frames of video. OpenCV contains

  1. Software OT&E Guidelines. Volume 1. Software Test Manager’s Handbook

    DTIC Science & Technology

    1981-02-01

    on reverse side If neceeary and identify by block number) The Software OT&E Guidelines is a set of handbooks prepared by the Computer / Support Systems...is one of a set of handbooks prepared by the Computer /Support Systems Division of the Test and Evaluation Directorate, Air Force Test and Evaluation...15 E. Software Maintainability .. .. ........ ... 16 F. Standard Questionnaires. .. .. ....... .... 16 1. Operator- Computer Interface Evaluation

  2. Review of CAI Materials.

    ERIC Educational Resources Information Center

    McCrary, Ronald G.

    A discussion of computer software and courseware for second-language instruction outlines considerations for selecting software of various kinds and presents a list of selected computer programs. Suggestions are made for choosing text-specific software, non-text-specific software intended for language instruction, word processors intended for…

  3. [Registration technology for mandibular angle osteotomy based on augmented reality].

    PubMed

    Zhu, Ming; Chai, Gang; Zhang, Yan; Ma, Xiao-Fei; Yu, Zhe-Yuan; Zhu, Yi-Jia

    2010-12-01

    To establish an effective path to register the operative plan to the real model of mandible made by rapid prototyping (RP) technology. Computerize tomography (CT) was performed on 20 patients to create 3D images, and computer aided operation planning information can be merged with the 3D images. Then dental cast was used to fix the signal which can be recognized by the software. The dental cast was transformed to 3D data with a laser scanner and a programmer that run on a personal computer named Rapidform matching the dental cast and the mandible image to generate the virtual image. Then the registration was achieved by video monitoring system. By using this technology, the virtual image of mandible and the cutting planes both can overlay the real model of mandible made by RP. This study found an effective way for registration by using dental cast, and this way might be a powerful option for the registration of augmented reality. Supported by Program for Innovation Research Team of Shanghai Municipal Education Commission.

  4. Cylindrical surface profile and diameter measuring tool and method

    NASA Technical Reports Server (NTRS)

    Currie, James R. (Inventor); Kissel, Ralph R. (Inventor); Smith, Earnest C. (Inventor); Oliver, Charles E. (Inventor); Redmon, John W., Sr. (Inventor); Wallace, Charles C. (Inventor); Swanson, Charles P. (Inventor)

    1987-01-01

    A tool is shown having a cross beam assembly made of beams joined by a center box structure. The assembly is adapted to be mounted by brackets to the outer end of a cylindrical case. The center box structure has a vertical shaft rotatably mounted therein and extending beneath the assembly. Secured to the vertical shaft is a radius arm which is adapted to rotate with the shaft. On the longer end of the radius arm is a measuring tip which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm. An electric servomotor rotates the vertical shaft and an electronic resolver provides an electric signal representing the angle of rotation of the shaft. The electric signals are provided to a computer station which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

  5. The implications of free 3D scanning in the conservation state assessment of old wood painted icon

    NASA Astrophysics Data System (ADS)

    Munteanu, Marius; Sandu, Ion

    2016-06-01

    The present paper presents the conservation state and the making of a 3D model of a XVIII-th century orthodox icon on wood support, using free available software and cloud computing. In order to create the 3D model of the painting layer of the icon a number of 70 pictures were taken using a Nikon DSLR D3300, 24.2 MP in setup with a Hama Star 75 photo tripod, in loops 360° around the painting, at three different angles. The pictures were processed with Autodesk I23D Catch, which automatically finds and matches common features among all of the uploaded photographs in order to create the 3D scene, using the power and speed of cloud computing. The obtained 3D model was afterwards analyzed and processed in order to obtain a final version, which can now be use to better identify, to map and to prioritize the future conservation processes and finally can be shared online as an animation.

  6. Validation Results for LEWICE 3.0

    NASA Technical Reports Server (NTRS)

    Wright, William B.

    2005-01-01

    A research project is underway at NASA Glenn to produce computer software that can accurately predict ice growth under any meteorological conditions for any aircraft surface. This report will present results from version 3.0 of this software, which is called LEWICE. This version differs from previous releases in that it incorporates additional thermal analysis capabilities, a pneumatic boot model, interfaces to computational fluid dynamics (CFD) flow solvers and has an empirical model for the supercooled large droplet (SLD) regime. An extensive comparison of the results in a quantifiable manner against the database of ice shapes and collection efficiency that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has also been performed. The complete set of data used for this comparison will eventually be available in a contractor report. This paper will show the differences in collection efficiency between LEWICE 3.0 and experimental data. Due to the large amount of validation data available, a separate report is planned for ice shape comparison. This report will first describe the LEWICE 3.0 model for water collection. A semi-empirical approach was used to incorporate first order physical effects of large droplet phenomena into icing software. Comparisons are then made to every single element two-dimensional case in the water collection database. Each condition was run using the following five assumptions: 1) potential flow, no splashing; 2) potential flow, no splashing with 21 bin drop size distributions and a lift correction (angle of attack adjustment); 3) potential flow, with splashing; 4) Navier-Stokes, no splashing; and 5) Navier-Stokes, with splashing. Quantitative comparisons are shown for impingement limit, maximum water catch, and total collection efficiency. The results show that the predicted results are within the accuracy limits of the experimental data for the majority of cases.

  7. S-Genius, a universal software platform with versatile inverse problem resolution for scatterometry

    NASA Astrophysics Data System (ADS)

    Fuard, David; Troscompt, Nicolas; El Kalyoubi, Ismael; Soulan, Sébastien; Besacier, Maxime

    2013-05-01

    S-Genius is a new universal scatterometry platform, which gathers all the LTM-CNRS know-how regarding the rigorous electromagnetic computation and several inverse problem solver solutions. This software platform is built to be a userfriendly, light, swift, accurate, user-oriented scatterometry tool, compatible with any ellipsometric measurements to fit and any types of pattern. It aims to combine a set of inverse problem solver capabilities — via adapted Levenberg- Marquard optimization, Kriging, Neural Network solutions — that greatly improve the reliability and the velocity of the solution determination. Furthermore, as the model solution is mainly vulnerable to materials optical properties, S-Genius may be coupled with an innovative material refractive indices determination. This paper will a little bit more focuses on the modified Levenberg-Marquardt optimization, one of the indirect method solver built up in parallel with the total SGenius software coding by yours truly. This modified Levenberg-Marquardt optimization corresponds to a Newton algorithm with an adapted damping parameter regarding the definition domains of the optimized parameters. Currently, S-Genius is technically ready for scientific collaboration, python-powered, multi-platform (windows/linux/macOS), multi-core, ready for 2D- (infinite features along the direction perpendicular to the incident plane), conical, and 3D-features computation, compatible with all kinds of input data from any possible ellipsometers (angle or wavelength resolved) or reflectometers, and widely used in our laboratory for resist trimming studies, etching features characterization (such as complex stack) or nano-imprint lithography measurements for instance. The work about kriging solver, neural network solver and material refractive indices determination is done (or about to) by other LTM members and about to be integrated on S-Genius platform.

  8. Mars Relay Lander and Orbiter Overflight Profile Estimation

    NASA Technical Reports Server (NTRS)

    Wallick, Michael N.; Allard, Daniel A.; Gladden, Roy E.; Peterson, Corey L.

    2012-01-01

    This software allows science and mission operations to view graphs of geometric overflights of satellites and landers within the Mars (or other planetary) networks. It improves on the MaROS Web interface within any modern Web browser, in that it adds new capabilities to the MaROS suite. The profile for an overflight is an important element for selecting communication/ overflight opportunities between the landers and orbiters within the Mars network. Unfortunately, determining these estimates is very computationally expensive and difficult to compute by hand. This software allows the user to select different overflights (via the existing MaROS Web interface) and specify the smoothness of the estimation. Estimates for the geometric relationship between a lander and an orbiter are determined based upon the orbital conditions of the orbiter at the moment the orbiter rises above the horizon from the perspective of the lander. It utilizes 2-body orbital equations to propagate the trajectory through the duration of the view period, and returns profiles that represent the range between the two vehicles, and the elevation and azimuth angles of the orbiter as measured from the lander s position. The algorithms assume a 2-body relationship with an ideal, spherical planetary body, so therefore can see errors less than 2% at polar landing sites on Mars. These algorithms are being implemented to provide rough estimates rapidly for the geometry of a geometric view period where more complete data is unavailable, such as for planning purposes. While other software for this task exists, each at the time of this reporting has been contained within a much more complicated package. This tool allows science and mission operations to view the estimates with a few clicks of the mouse.

  9. Computers and Young Children. Storyboard Software: Flannel Boards in the Computer Age.

    ERIC Educational Resources Information Center

    Shade, Daniel D.

    1995-01-01

    Describes storyboard software as computer programs with which children can build a story using visuals. Notes the importance of such programs from preliterate or nonreading children. Describes a new storyboard program, "Wiggins in Storyland," and its features. Lists recommended storyboard software programs, with publishers and compatible…

  10. Browsing Software of the Visible Korean Data Used for Teaching Sectional Anatomy

    ERIC Educational Resources Information Center

    Shin, Dong Sun; Chung, Min Suk; Park, Hyo Seok; Park, Jin Seo; Hwang, Sung Bae

    2011-01-01

    The interpretation of computed tomographs (CTs) and magnetic resonance images (MRIs) to diagnose clinical conditions requires basic knowledge of sectional anatomy. Sectional anatomy has traditionally been taught using sectioned cadavers, atlases, and/or computer software. The computer software commonly used for this subject is practical and…

  11. Virus Alert: Ten Steps to Safe Computing.

    ERIC Educational Resources Information Center

    Gunter, Glenda A.

    1997-01-01

    Discusses computer viruses and explains how to detect them; discusses virus protection and the need to update antivirus software; and offers 10 safe computing tips, including scanning floppy disks and commercial software, how to safely download files from the Internet, avoiding pirated software copies, and backing up files. (LRW)

  12. 77 FR 50720 - Test Documentation for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Test Documentation for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1207, ``Test Documentation for Digital... practices for test documentation for software and computer systems as described in the Institute of...

  13. Using Flash Technology for Motivation and Assessment

    ERIC Educational Resources Information Center

    Deal, Walter F., III

    2004-01-01

    A visit to most any technology education laboratory or classroom will reveal that computers, software, and multimedia software are rapidly becoming a mainstay in learning about technology and technological literacy. Almost all technology labs have at least several computers dedicated to specialized software or hardware such as Computer-aided…

  14. Library and Classroom Use of Copyrighted Videotapes and Computer Software.

    ERIC Educational Resources Information Center

    Reed, Mary Hutchings; Stanek, Debra

    1986-01-01

    This pullout guide addresses issues regarding library use of copyrighted videotapes and computer software. Guidelines for videotapes cover in-classroom use, in-library use in public library, loan, and duplication. Guidelines for computer software cover purchase conditions, avoiding license restrictions, loaning, archival copies, and in-library and…

  15. Analysis of Five Instructional Methods for Teaching Sketchpad to Junior High Students

    ERIC Educational Resources Information Center

    Wright, Geoffrey; Shumway, Steve; Terry, Ronald; Bartholomew, Scott

    2012-01-01

    This manuscript addresses a problem teachers of computer software applications face today: What is an effective method for teaching new computer software? Technology and engineering teachers, specifically those with communications and other related courses that involve computer software applications, face this problem when teaching computer…

  16. Software design studies emphasizing Project LOGOS

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The results of a research project on the development of computer software are presented. Research funds of $200,000 were expended over a three year period for software design and projects in connection with Project LOGOS (computer-aided design and certification of computing systems). Abstracts of theses prepared during the project are provided.

  17. 78 FR 66865 - Acquisition Regulation: Patents, Data, and Copyrights

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... obligations under current law. The proposed changes include policy revisions for computer software developed.... Computer Software DOE's existing Rights in Technical Data-Technology Transfer clause at 970.5227-2 provides mechanisms by which computer software first produced by a DOE contractor may be made available to the public...

  18. 76 FR 13665 - The Mega Life & Health Ins. Co., a Subsidiary of Healthmarkets, Inc., Including Workers Whose...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... Computer Solutions and Software International, Inc., Dell Service Sales, Emdeon Business Services, KFORCE... workers from Computer Solutions and Software International, Inc., Dell Service Sales, Emdeon Business... from Computer Solutions and Software International, Inc., Dell Service Sales, Emdeon Business Services...

  19. Space Trajectory Error Analysis Program (STEAP) for halo orbit missions. Volume 1: Analytic and user's manual

    NASA Technical Reports Server (NTRS)

    Byrnes, D. V.; Carney, P. C.; Underwood, J. W.; Vogt, E. D.

    1974-01-01

    Development, test, conversion, and documentation of computer software for the mission analysis of missions to halo orbits about libration points in the earth-sun system is reported. The software consisting of two programs called NOMNAL and ERRAN is part of the Space Trajectories Error Analysis Programs (STEAP). The program NOMNAL targets a transfer trajectory from Earth on a given launch date to a specified halo orbit on a required arrival date. Either impulsive or finite thrust insertion maneuvers into halo orbit are permitted by the program. The transfer trajectory is consistent with a realistic launch profile input by the user. The second program ERRAN conducts error analyses of the targeted transfer trajectory. Measurements including range, doppler, star-planet angles, and apparent planet diameter are processed in a Kalman-Schmidt filter to determine the trajectory knowledge uncertainty. Execution errors at injection, midcourse correction and orbit insertion maneuvers are analyzed along with the navigation uncertainty to determine trajectory control uncertainties and fuel-sizing requirements. The program is also capable of generalized covariance analyses.

  20. Vibrational frequency analysis, FT-IR, DFT and M06-2X studies on tert-Butyl N-(thiophen-2yl)carbamate

    NASA Astrophysics Data System (ADS)

    Sert, Yusuf; Singer, L. M.; Findlater, M.; Doğan, Hatice; Çırak, Ç.

    2014-07-01

    In this study, the experimental and theoretical vibrational frequencies of a newly synthesized tert-Butyl N-(thiophen-2yl)carbamate have been investigated. The experimental FT-IR (4000-400 cm-1) spectrum of the molecule in the solid phase have been recorded. The theoretical vibrational frequencies and optimized geometric parameters (bond lengths and bond angles) have been calculated by using density functional theory (DFT/B3LYP: Becke, 3-parameter, Lee-Yang-Parr) and DFT/M06-2X (the highly parametrized, empirical exchange correlation function) quantum chemical methods with the 6-311++G(d,p) basis set by Gaussian 09W software, for the first time. The vibrational frequencies have been assigned using potential energy distribution (PED) analysis by using VEDA 4 software. The computational optimized geometric parameters and vibrational frequencies have been found to be in good agreement with the corresponding experimental data, and with related literature results. In addition, the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbital (LUMO) energies and the other related molecular energy values have been calculated and are depicted.

Top