Science.gov

Sample records for computer-aided dispatching system

  1. Computer-aided dispatching system design specification

    SciTech Connect

    Briggs, M.G.

    1997-12-16

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP).

  2. Computer-Aided dispatching system design specification

    SciTech Connect

    Briggs, M.G.

    1996-05-03

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol emergency response. This system is defined as a Commercial-Off the-Shelf computer dispatching system providing both text and graphical display information while interfacing with the diverse reporting system within the Hanford Facility. This system also provided expansion capabilities to integrate Hanford Fire and the Occurrence Notification Center and provides back-up capabilities for the Plutonium Processing Facility.

  3. Computer-Aided dispatching system design specification

    SciTech Connect

    Briggs, M.G.

    1996-09-27

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol emergency response. This document outlines the negotiated requirements as agreed to by GTE Northwest during technical contract discussions. This system defines a commercial off-the-shelf computer dispatching system providing both test and graphic display information while interfacing with diverse alarm reporting system within the Hanford Site. This system provided expansion capability to integrate Hanford Fire and the Occurrence Notification Center. The system also provided back-up capability for the Plutonium Processing Facility (PFP).

  4. Computer-aided radio dispatch system streamlines operations

    SciTech Connect

    Meck, G.L.

    1985-10-01

    This paper describes a computer-aided radio dispatch system (CARDS) used by The East Ohio Gas Company to help improve customer satisfaction and the already high level of performance in customer service operations. East Ohio decided to develop its own system after establishing certain criteria. The heart of the Cards unit is the DEC microcomputer LSI-11 where data is transmitted between it and the dispatch centers at 1,200 baud. The large number of job functions that the system helps fulfill are discussed in this paper.

  5. Application of computer-aided dispatch in law enforcement: An introductory planning guide

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.; Gurfield, R. M.; Garcia, E. A.; Fielding, J. E.

    1975-01-01

    A set of planning guidelines for the application of computer-aided dispatching (CAD) to law enforcement is presented. Some essential characteristics and applications of CAD are outlined; the results of a survey of systems in the operational or planning phases are summarized. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Detailed descriptions of typical law enforcement CAD systems, and a list of vendor sources, are given in appendixes.

  6. The NASA/Baltimore Applications Project (BAP). Computer aided dispatch and communications system for the Baltimore Fire Department: A case study of urban technology application

    NASA Technical Reports Server (NTRS)

    Levine, A. L.

    1981-01-01

    An engineer and a computer expert from Goddard Space Flight Center were assigned to provide technical assistance in the design and installation of a computer assisted system for dispatching and communicating with fire department personnel and equipment in Baltimore City. Primary contributions were in decision making and management processes. The project is analyzed from four perspectives: (1) fire service; (2) technology transfer; (3) public administration; and (5) innovation. The city benefitted substantially from the approach and competence of the NASA personnel. Given the proper conditions, there are distinct advantages in having a nearby Federal laboratory provide assistance to a city on a continuing basis, as is done in the Baltimore Applications Project.

  7. Computer-aided system design

    NASA Technical Reports Server (NTRS)

    Walker, Carrie K.

    1991-01-01

    A technique has been developed for combining features of a systems architecture design and assessment tool and a software development tool. This technique reduces simulation development time and expands simulation detail. The Architecture Design and Assessment System (ADAS), developed at the Research Triangle Institute, is a set of computer-assisted engineering tools for the design and analysis of computer systems. The ADAS system is based on directed graph concepts and supports the synthesis and analysis of software algorithms mapped to candidate hardware implementations. Greater simulation detail is provided by the ADAS functional simulator. With the functional simulator, programs written in either Ada or C can be used to provide a detailed description of graph nodes. A Computer-Aided Software Engineering tool developed at the Charles Stark Draper Laboratory (CSDL CASE) automatically generates Ada or C code from engineering block diagram specifications designed with an interactive graphical interface. A technique to use the tools together has been developed, which further automates the design process.

  8. CAESY - COMPUTER AIDED ENGINEERING SYSTEM

    NASA Technical Reports Server (NTRS)

    Wette, M. R.

    1994-01-01

    Many developers of software and algorithms for control system design have recognized that current tools have limits in both flexibility and efficiency. Many forces drive the development of new tools including the desire to make complex system modeling design and analysis easier and the need for quicker turnaround time in analysis and design. Other considerations include the desire to make use of advanced computer architectures to help in control system design, adopt new methodologies in control, and integrate design processes (e.g., structure, control, optics). CAESY was developed to provide a means to evaluate methods for dealing with user needs in computer-aided control system design. It is an interpreter for performing engineering calculations and incorporates features of both Ada and MATLAB. It is designed to be reasonably flexible and powerful. CAESY includes internally defined functions and procedures, as well as user defined ones. Support for matrix calculations is provided in the same manner as MATLAB. However, the development of CAESY is a research project, and while it provides some features which are not found in commercially sold tools, it does not exhibit the robustness that many commercially developed tools provide. CAESY is written in C-language for use on Sun4 series computers running SunOS 4.1.1 and later. The program is designed to optionally use the LAPACK math library. The LAPACK math routines are available through anonymous ftp from research.att.com. CAESY requires 4Mb of RAM for execution. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. CAESY was developed in 1993 and is a copyrighted work with all copyright vested in NASA.

  9. Computer Aided Control System Design (CACSD)

    NASA Technical Reports Server (NTRS)

    Stoner, Frank T.

    1993-01-01

    The design of modern aerospace systems relies on the efficient utilization of computational resources and the availability of computational tools to provide accurate system modeling. This research focuses on the development of a computer aided control system design application which provides a full range of stability analysis and control design capabilities for aerospace vehicles.

  10. A rule based computer aided design system

    NASA Technical Reports Server (NTRS)

    Premack, T.

    1986-01-01

    A Computer Aided Design (CAD) system is presented which supports the iterative process of design, the dimensional continuity between mating parts, and the hierarchical structure of the parts in their assembled configuration. Prolog, an interactive logic programming language, is used to represent and interpret the data base. The solid geometry representing the parts is defined in parameterized form using the swept volume method. The system is demonstrated with a design of a spring piston.

  11. RASCAL: A Rudimentary Adaptive System for Computer-Aided Learning.

    ERIC Educational Resources Information Center

    Stewart, John Christopher

    Both the background of computer-assisted instruction (CAI) systems in general and the requirements of a computer-aided learning system which would be a reasonable assistant to a teacher are discussed. RASCAL (Rudimentary Adaptive System for Computer-Aided Learning) is a first attempt at defining a CAI system which would individualize the learning…

  12. Software For Computer-Aided Design Of Control Systems

    NASA Technical Reports Server (NTRS)

    Wette, Matthew

    1994-01-01

    Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.

  13. PLAID- A COMPUTER AIDED DESIGN SYSTEM

    NASA Technical Reports Server (NTRS)

    Brown, J. W.

    1994-01-01

    PLAID is a three-dimensional Computer Aided Design (CAD) system which enables the user to interactively construct, manipulate, and display sets of highly complex geometric models. PLAID was initially developed by NASA to assist in the design of Space Shuttle crewstation panels, and the detection of payload object collisions. It has evolved into a more general program for convenient use in many engineering applications. Special effort was made to incorporate CAD techniques and features which minimize the users workload in designing and managing PLAID models. PLAID consists of three major modules: the Primitive Object Generator (BUILD), the Composite Object Generator (COG), and the DISPLAY Processor. The BUILD module provides a means of constructing simple geometric objects called primitives. The primitives are created from polygons which are defined either explicitly by vertex coordinates, or graphically by use of terminal crosshairs or a digitizer. Solid objects are constructed by combining, rotating, or translating the polygons. Corner rounding, hole punching, milling, and contouring are special features available in BUILD. The COG module hierarchically organizes and manipulates primitives and other previously defined COG objects to form complex assemblies. The composite object is constructed by applying transformations to simpler objects. The transformations which can be applied are scalings, rotations, and translations. These transformations may be defined explicitly or defined graphically using the interactive COG commands. The DISPLAY module enables the user to view COG assemblies from arbitrary viewpoints (inside or outside the object) both in wireframe and hidden line renderings. The PLAID projection of a three-dimensional object can be either orthographic or with perspective. A conflict analysis option enables detection of spatial conflicts or collisions. DISPLAY provides camera functions to simulate a view of the model through different lenses. Other

  14. Toward Computer-Aided Affective Learning Systems: A Literature Review

    ERIC Educational Resources Information Center

    Moridis, C. N.; Economides, A. A.

    2008-01-01

    The aim of this survey is to provide an overview of the various components of "computer aided affective learning systems." The research is classified into 3 main scientific areas that are integral parts of the development of these kinds of systems. The three main scientific areas are: i) emotions and their connection to learning; ii) affect…

  15. Computer-aided Instructional System for Transmission Line Simulation.

    ERIC Educational Resources Information Center

    Reinhard, Erwin A.; Roth, Charles H., Jr.

    A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…

  16. Computer-Aided Personalized System of Instruction: A Program Evaluation.

    ERIC Educational Resources Information Center

    Pear, Joseph J.; Novak, Mark

    1996-01-01

    Presents an evaluation of a computer-aided personalized system of instruction program in two undergraduate psychology courses. The computer presented short essay tests and arranged for students who had completed various assignments satisfactorily to help evaluate other students' mastery of those assignments. Student response generally was…

  17. Space systems computer-aided design technology

    NASA Technical Reports Server (NTRS)

    Garrett, L. B.

    1984-01-01

    The interactive Design and Evaluation of Advanced Spacecraft (IDEAS) system is described, together with planned capability increases in the IDEAS system. The system's disciplines consist of interactive graphics and interactive computing. A single user at an interactive terminal can create, design, analyze, and conduct parametric studies of earth-orbiting satellites, which represents a timely and cost-effective method during the conceptual design phase where various missions and spacecraft options require evaluation. Spacecraft concepts evaluated include microwave radiometer satellites, communication satellite systems, solar-powered lasers, power platforms, and orbiting space stations.

  18. Computer-aided protective system (CAPS)

    SciTech Connect

    Squire, R.K.

    1988-01-01

    A method of improving the security of materials in transit is described. The system provides a continuously monitored position location system for the transport vehicle, an internal computer-based geographic delimiter that makes continuous comparisons of actual positions with the preplanned routing and schedule, and a tamper detection/reaction system. The position comparison is utilized to institute preprogrammed reactive measures if the carrier is taken off course or schedule, penetrated, or otherwise interfered with. The geographic locater could be an independent internal platform or an external signal-dependent system utilizing GPS, Loran or similar source of geographic information; a small (micro) computer could provide adequate memory and computational capacity; the insurance of integrity of the system indicates the need for a tamper-proof container and built-in intrusion sensors. A variant of the system could provide real-time transmission of the vehicle position and condition to a central control point for; such transmission could be encrypted to preclude spoofing.

  19. Integrated computer-aided retinal photocoagulation system

    NASA Astrophysics Data System (ADS)

    Barrett, Steven F.; Wright, Cameron H. G.; Oberg, Erik D.; Rockwell, Benjamin A.; Cain, Clarence P.; Jerath, Maya R.; Rylander, Henry G., III; Welch, Ashley J.

    1996-05-01

    Successful retinal tracking subsystem testing results in vivo on rhesus monkeys using an argon continuous wave laser and an ultra-short pulse laser are presented. Progress on developing an integrated robotic retinal laser surgery system is also presented. Several interesting areas of study have developed: (1) 'doughnut' shaped lesions that occur under certain combinations of laser power, spot size, and irradiation time complicating measurements of central lesion reflectance, (2) the optimal retinal field of view to achieve simultaneous tracking and lesion parameter control, and (3) a fully digital versus a hybrid analog/digital tracker using confocal reflectometry integrated system implementation. These areas are investigated in detail in this paper. The hybrid system warrants a separate presentation and appears in another paper at this conference.

  20. Computer-Aided Fabrication System Implementation

    DTIC Science & Technology

    1988-09-30

    expanded to include Lisp interface routines in addition to C interface routines by Ken lshii. Mike Ruf has completed his S.M. thesis proposal, " Management ...System," was completed by Nazhin S. Zarghamee in May, 1988. This software provides a schema display so as to allow lab managers and users to provide more...these is a prototype Simulation Manager , which has as a key component a translator from the PFL representation of the process to the input required by

  1. A Computer Aided Statistical Covariance Program for Missile System Analysis

    DTIC Science & Technology

    1974-04-01

    ENGINEERING RESEARCH OKLAHOMA STATE UNIVERSITY A COMPUTER AIDED STATISTICAL COVARIANCE PROGRAM FOR MISSILE SYSTEM ANALYSI. TO D JN2 U. S. Army Missile...ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK AREA & WORK UNIT NUMBERS Office of Engineering Rsch, Oklahoma State Univ Agiculture...ANALYSIS by James R. Rowland and V. M. Gupta School of Electrical Engineering V Approved for public release; distribution unlimited. Office of Engineering

  2. Computer-Aided Final Design Cost Estimating System Overview.

    DTIC Science & Technology

    1977-05-01

    laboratory _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ /1— COMPUTER-AIDED FINAL DESIGN • COST ESTIMATING SYSTEM OVERVIEW © by...PROJECT . TASKAAEA~~ WORK UNIT NUMBERSCONSTRUCTION ENGINEERING RESEARCH LABORATORY ~~~~~~~~~ .• . — P.O. Box 4005 ~~ 4A7627~ %T4fldt11 Champa ign , IL 61820...Construction Division (FA), U.S. Army Construction Engineering Re- search Laboratory (CERL), Champaign , IL. The Principal Investigator was Mr. Michael

  3. Computer-aided auscultation learning system for nursing technique instruction.

    PubMed

    Hou, Chun-Ju; Chen, Yen-Ting; Hu, Ling-Chen; Chuang, Chih-Chieh; Chiu, Yu-Hsien; Tsai, Ming-Shih

    2008-01-01

    Pulmonary auscultation is a physical assessment skill learned by nursing students for examining the respiratory system. Generally, a sound simulator equipped mannequin is used to group teach auscultation techniques via classroom demonstration. However, nursing students cannot readily duplicate this learning environment for self-study. The advancement of electronic and digital signal processing technologies facilitates simulating this learning environment. This study aims to develop a computer-aided auscultation learning system for assisting teachers and nursing students in auscultation teaching and learning. This system provides teachers with signal recording and processing of lung sounds and immediate playback of lung sounds for students. A graphical user interface allows teachers to control the measuring device, draw lung sound waveforms, highlight lung sound segments of interest, and include descriptive text. Effects on learning lung sound auscultation were evaluated for verifying the feasibility of the system. Fifteen nursing students voluntarily participated in the repeated experiment. The results of a paired t test showed that auscultative abilities of the students were significantly improved by using the computer-aided auscultation learning system.

  4. Computer aided systems human engineering: A hypermedia tool

    NASA Technical Reports Server (NTRS)

    Boff, Kenneth R.; Monk, Donald L.; Cody, William J.

    1992-01-01

    The Computer Aided Systems Human Engineering (CASHE) system, Version 1.0, is a multimedia ergonomics database on CD-ROM for the Apple Macintosh II computer, being developed for use by human system designers, educators, and researchers. It will initially be available on CD-ROM and will allow users to access ergonomics data and models stored electronically as text, graphics, and audio. The CASHE CD-ROM, Version 1.0 will contain the Boff and Lincoln (1988) Engineering Data Compendium, MIL-STD-1472D and a unique, interactive simulation capability, the Perception and Performance Prototyper. Its features also include a specialized data retrieval, scaling, and analysis capability and the state of the art in information retrieval, browsing, and navigation.

  5. A handheld computer-aided diagnosis system and simulated analysis

    NASA Astrophysics Data System (ADS)

    Su, Mingjian; Zhang, Xuejun; Liu, Brent; Su, Kening; Louie, Ryan

    2016-03-01

    This paper describes a Computer Aided Diagnosis (CAD) system based on cellphone and distributed cluster. One of the bottlenecks in building a CAD system for clinical practice is the storage and process of mass pathology samples freely among different devices, and normal pattern matching algorithm on large scale image set is very time consuming. Distributed computation on cluster has demonstrated the ability to relieve this bottleneck. We develop a system enabling the user to compare the mass image to a dataset with feature table by sending datasets to Generic Data Handler Module in Hadoop, where the pattern recognition is undertaken for the detection of skin diseases. A single and combination retrieval algorithm to data pipeline base on Map Reduce framework is used in our system in order to make optimal choice between recognition accuracy and system cost. The profile of lesion area is drawn by doctors manually on the screen, and then uploads this pattern to the server. In our evaluation experiment, an accuracy of 75% diagnosis hit rate is obtained by testing 100 patients with skin illness. Our system has the potential help in building a novel medical image dataset by collecting large amounts of gold standard during medical diagnosis. Once the project is online, the participants are free to join and eventually an abundant sample dataset will soon be gathered enough for learning. These results demonstrate our technology is very promising and expected to be used in clinical practice.

  6. A computer-aided diagnostic system for kidney disease

    PubMed Central

    Jahantigh, Farzad Firouzi; Malmir, Behnam; Avilaq, Behzad Aslani

    2017-01-01

    Background Disease diagnosis is complicated since patients may demonstrate similar symptoms but physician may diagnose different diseases. There are a few number of investigations aimed to create a fuzzy expert system, as a computer aided system for disease diagnosis. Methods In this research, a cross-sectional descriptive study conducted in a kidney clinic in Tehran, Iran in 2012. Medical diagnosis fuzzy rules applied, and a set of symptoms related to the set of considered diseases defined. The input case to be diagnosed defined by assigning a fuzzy value to each symptom and then three physicians asked about each suspected diseases. Then comments of those three physicians summarized for each disease. The fuzzy inference applied to obtain a decision fuzzy set for each disease, and crisp decision values attained to determine the certainty of existence for each disease. Results Results indicated that, in the diagnosis of seven cases of kidney disease by examining 21 indicators using fuzzy expert system, kidney stone disease with 63% certainty was the most probable, renal tubular was at the lowest level with 15%, and other kidney diseases were at the other levels. The most remarkable finding of this study was that results of kidney disease diagnosis (e.g., kidney stone) via fuzzy expert system were fully compatible with those of kidney physicians. Conclusion The proposed fuzzy expert system is a valid, reliable, and flexible instrument to diagnose several typical input cases. The developed system decreases the effort of initial physical checking and manual feeding of input symptoms. PMID:28392995

  7. Computer aided production planning - SWZ system of order verification

    NASA Astrophysics Data System (ADS)

    Krenczyk, D.; Skolud, B.

    2015-11-01

    SWZ (System of order verification) is a computer implementation of the methodology that support fast decision making on the acceptability of a production order, which allows to determine not the best possible solution, but admissible solution that is possible to find in an acceptable time (feasible solution) and acceptable due to the existing constraints. The methodology uses the propagation of constraints techniques and reduced to test a sequence of arbitrarily selected conditions. Fulfilment of all the conditions (the conjunction) provides the ability to perform production orders. In the paper examples of the application of SWZ system comprising the steps of planning and control is presented. The obtained results allowing the determination of acceptable production flow in the system - determination of the manufacturing system parameters those that ensure execution of orders in time under the resource constraints. SWZ also allows to generate the dispatching rules as a sequence of processing operations for each production resource, performed periodically during the production flow in the system. Furthermore the example of SWZ and simulation system integration is shown. SWZ has been enhanced with a module generating files containing the script code of the system model using the internal language of simulation and visualization system.

  8. A Learning Health Care System Using Computer-Aided Diagnosis.

    PubMed

    Cahan, Amos; Cimino, James J

    2017-03-08

    Physicians intuitively apply pattern recognition when evaluating a patient. Rational diagnosis making requires that clinical patterns be put in the context of disease prior probability, yet physicians often exhibit flawed probabilistic reasoning. Difficulties in making a diagnosis are reflected in the high rates of deadly and costly diagnostic errors. Introduced 6 decades ago, computerized diagnosis support systems are still not widely used by internists. These systems cannot efficiently recognize patterns and are unable to consider the base rate of potential diagnoses. We review the limitations of current computer-aided diagnosis support systems. We then portray future diagnosis support systems and provide a conceptual framework for their development. We argue for capturing physician knowledge using a novel knowledge representation model of the clinical picture. This model (based on structured patient presentation patterns) holds not only symptoms and signs but also their temporal and semantic interrelations. We call for the collection of crowdsourced, automatically deidentified, structured patient patterns as means to support distributed knowledge accumulation and maintenance. In this approach, each structured patient pattern adds to a self-growing and -maintaining knowledge base, sharing the experience of physicians worldwide. Besides supporting diagnosis by relating the symptoms and signs with the final diagnosis recorded, the collective pattern map can also provide disease base-rate estimates and real-time surveillance for early detection of outbreaks. We explain how health care in resource-limited settings can benefit from using this approach and how it can be applied to provide feedback-rich medical education for both students and practitioners.

  9. A Learning Health Care System Using Computer-Aided Diagnosis

    PubMed Central

    Cimino, James J

    2017-01-01

    Physicians intuitively apply pattern recognition when evaluating a patient. Rational diagnosis making requires that clinical patterns be put in the context of disease prior probability, yet physicians often exhibit flawed probabilistic reasoning. Difficulties in making a diagnosis are reflected in the high rates of deadly and costly diagnostic errors. Introduced 6 decades ago, computerized diagnosis support systems are still not widely used by internists. These systems cannot efficiently recognize patterns and are unable to consider the base rate of potential diagnoses. We review the limitations of current computer-aided diagnosis support systems. We then portray future diagnosis support systems and provide a conceptual framework for their development. We argue for capturing physician knowledge using a novel knowledge representation model of the clinical picture. This model (based on structured patient presentation patterns) holds not only symptoms and signs but also their temporal and semantic interrelations. We call for the collection of crowdsourced, automatically deidentified, structured patient patterns as means to support distributed knowledge accumulation and maintenance. In this approach, each structured patient pattern adds to a self-growing and -maintaining knowledge base, sharing the experience of physicians worldwide. Besides supporting diagnosis by relating the symptoms and signs with the final diagnosis recorded, the collective pattern map can also provide disease base-rate estimates and real-time surveillance for early detection of outbreaks. We explain how health care in resource-limited settings can benefit from using this approach and how it can be applied to provide feedback-rich medical education for both students and practitioners. PMID:28274905

  10. Integrated Energy System Dispatch Optimization

    SciTech Connect

    Firestone, Ryan; Stadler, Michael; Marnay, Chris

    2006-06-16

    On-site cogeneration of heat and electricity, thermal and electrical storage, and curtailing/rescheduling demand options are often cost-effective to commercial and industrial sites. This collection of equipment and responsive consumption can be viewed as an integrated energy system(IES). The IES can best meet the sites cost or environmental objectives when controlled in a coordinated manner. However, continuously determining this optimal IES dispatch is beyond the expectations for operators of smaller systems. A new algorithm is proposed in this paper to approximately solve the real-time dispatch optimization problem for a generic IES containing an on-site cogeneration system subject to random outages, limited curtailment opportunities, an intermittent renewable electricity source, and thermal storage. An example demonstrates how this algorithm can be used in simulation to estimate the value of IES components.

  11. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system.

    PubMed

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T = 62.6 ± 65.2 μm ; MC = 60.4 ± 38.4 μm; PMC = 58.1 ± 38.0 μm, and RI = 89.8 ± 62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T = 71.5%, RI = 49.2%, MC = 69.6%, and PMC = 71.2%. The percentages of horizontal overextension were T = 8.5%, RI = 0%, MC = 0.8%, and PMC = 3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  12. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    NASA Astrophysics Data System (ADS)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  13. Expert validation of the knowledge base for E-CAD - a pre-hospital dispatch triage decision support system.

    PubMed

    Mirza, Muzna; Saini, Devashish; Brown, Todd B; Orthner, Helmuth F; Mazza, Giovanni; Battles, Marcie M

    2007-10-11

    The knowledge base (KB) for E-CAD (Enhanced Computer-Aided Dispatch), a triage decision support system for Emergency Medical Dispatch (EMD) of medical resources in trauma cases, is being evaluated. We aim to achieve expert consensus for validation and refinement of the E-CAD KB using the modified Delphi technique. Evidence-based, expert-validated and refined KB will provide improved EMD practice guidelines and may facilitate acceptance of the E-CAD by state-wide professionals.

  14. Study on computer-aided alignment method of reflective zoom systems

    NASA Astrophysics Data System (ADS)

    Zhou, Jide; Chang, Jun; Xie, Guijuan; Zhang, Ke

    2015-08-01

    Computer-aided alignment is an effective method to improve the imaging quality of high-precision, complex, and off-axis optical systems. However, how to determine the misalignment quickly, exactly and constantly is essential to the technology of computer-aided alignment. Owing to the varying optical characteristics of a zoom system, sensitivity matrices are used in the alignment rather than a single matrix. Thus, the processing of sensitivity matrices is important for the computer-aided alignment of the reflective zoom system. So, the total least squares is proposed in order to solve the problems of the numerical instability and the result inaccuracy which result from the solution of the least squares method directly. Finally, the simulant calculation is processed using the numerical analysis model established in the essay. The results demonstrate that the computation method is rational and effective.

  15. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    ERIC Educational Resources Information Center

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  16. Experience gained at ZAO Ural Turbine Works with the use of computer-aided design systems

    NASA Astrophysics Data System (ADS)

    Kortenko, V. V.; Valamin, A. E.; Shanturov, D. N.; Sokolov, E. V.; Toibich, S. V.; Glushchenko, A. N.

    2008-08-01

    The results of work accomplished in the field of computer-aided design at ZAO Ural Turbine Works (UTZ) are presented. A concept is described following which the tasks for a specialist’s workstations being developed at the UTZ are solved. Results from solution of problems with the use of modern numerical simulation computer programs for analyzing gas dynamic processes, casting, welding, and strength of complex structures are given. An example is given to show efficient use of a computer-aided design system for shifting an enterprise to a modern level of automation.

  17. Persons with Alzheimer's Disease Make Phone Calls Independently Using a Computer-Aided Telephone System

    ERIC Educational Resources Information Center

    Perilli, Viviana; Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Cassano, Germana; Cordiano, Noemi; Pinto, Katia; Minervini, Mauro G.; Oliva, Doretta

    2012-01-01

    This study assessed whether four patients with a diagnosis of Alzheimer's disease could make independent phone calls via a computer-aided telephone system. The study was carried out according to a non-concurrent multiple baseline design across participants. All participants started with baseline during which the telephone system was not available,…

  18. Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.

    PubMed

    Liedlgruber, Michael; Uhl, Andreas

    2011-01-01

    Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.

  19. A Computer-Aided Self-Testing System for Biological Psychology.

    ERIC Educational Resources Information Center

    Leiblum, M. D.; And Others

    1994-01-01

    Describes the production of a computer-aided, self-testing system for university students enrolled in a first-year course in biological psychology. Project aspects described include selection, acquisition and description of software; question banks and test structures; modes of use (computer or printed version); evaluation; and future plans. (11…

  20. Implementation and Evaluation of Computer-Aided Mandarin Phonemes Training System for Hearing-Impaired Students

    ERIC Educational Resources Information Center

    Yang, Hui-Jen; Lay, Yun-Long

    2005-01-01

    A computer-aided Mandarin phonemes training (CAMPT) system was developed and evaluated for training hearing-impaired students in their pronunciation of Mandarin phonemes. Deaf or hearing-impaired people have difficulty hearing their own voice, hence most of them cannot learn how to speak. Phonemes are the basis for learning to read and speak in…

  1. Minnesota Computer Aided Library System (MCALS); University of Minnesota Subsystem Cost/Benefits Analysis.

    ERIC Educational Resources Information Center

    Lourey, Eugene D., Comp.

    The Minnesota Computer Aided Library System (MCALS) provides a basis of unification for library service program development in Minnesota for eventual linkage to the national information network. A prototype plan for communications functions is illustrated. A cost/benefits analysis was made to show the cost/effectiveness potential for MCALS. System…

  2. Performance Measures in Courses Using Computer-Aided Personalized System of Instruction

    ERIC Educational Resources Information Center

    Springer, C. R.; Pear, J. J.

    2008-01-01

    Archived data from four courses taught with computer-aided personalized system of instruction (CAPSI)--an online, self-paced, instructional program--were used to explore the relationship between objectively rescored final exam grades, peer reviewing, and progress rate--i.e., the rate at which students completed unit tests. There was a strong…

  3. Computer-Aided Personalized System of Instruction for the Virtual Classroom.

    ERIC Educational Resources Information Center

    Kinser, W.; Pear, J. J.

    1988-01-01

    Describes a computer-aided personalized system of instruction (CAPSI) and its implementations for both on-campus and off-campus teaching at the University of Manitoba. Highlights include electronic mail, student reactions, the use of data that are saved throughout the course, and future possibilities. (Author/LRW)

  4. Computer-aided design and computer-aided manufacture (CAD/CAM) system for construction of spinal orthosis for patients with adolescent idiopathic scoliosis.

    PubMed

    Wong, M S

    2011-01-01

    ABSTRACT Spinal orthoses are commonly prescribed to patients with moderate adolescent idiopathic scoliosis (AIS) for prevention of further curve deterioration. In conventional manufacturing method, plaster bandages are used to obtain the patient's body contour and then the plaster cast is rectified manually. With computer-aided design and computer-aided manufacture (CAD/CAM) system, a series of automated processes from body scanning to digital rectification and milling of the positive model can be performed in a fast and accurate fashion. The purpose of this manuscript is to introduce the application of CAD/CAM system to the construction of spinal orthosis for patients with AIS. Based on evidence within the literature, CAD/CAM method can achieve similar clinical outcomes but with higher efficiency than the conventional fabrication method. Therefore, CAD/CAM method should be considered a substitute to the conventional method in fabrication of spinal orthoses for patients with AIS.

  5. Computer Aided Method for System Safety and Reliability Assessments

    DTIC Science & Technology

    2008-09-01

    instruction, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information...aspects of safety within the constraints of operational effectiveness, time and cost throughout all phases of the system life cycle.” Often there...contributes to systems engineering objectives by applying a set of safety design requirements throughout all life cycle phases of a system, whether

  6. Computer-aided-analysis of linear control system robustness

    NASA Technical Reports Server (NTRS)

    Stengel, Robert F.; Ray, Laura R.

    1990-01-01

    Stochastic robustness is a simple technique used to estimate the stability and performance robustness of linear, time-invariant systems. The use of high-speed graphics workstations and control system design software in stochastic robustness analysis is discussed and demonstrated. It is shown that stochastic robustness makes good use of modern computational and graphic tools, and it is easily implemented using commercial control system design and analysis software.

  7. Computer aided design of jet engine test cell exhaust systems

    SciTech Connect

    Collings, D.

    1982-01-01

    A computerized design procedure that provides a multi-directional analysis of available data is a proven method of developing accurate cost models and performing system trade-offs. The application to the engineering of exhaust silencing systems for jet engine test cells is discused.

  8. Web-Based Computer-Aided Personalized System of Instruction

    ERIC Educational Resources Information Center

    Pear, Joseph J.; Schnerch, Gabriel J.; Silva, Kathleen M.; Svenningsen, Louis; Lambert, Jody

    2011-01-01

    In the last two decades, there has been a proliferation of Web-based course-management systems designed to facilitate postsecondary teaching (for example, WebCT, Blackboard, Desire2Learn, Moodle). In general, these systems provide analogs for delivering lectures, holding class discussions, giving quizzes and examinations (typically multiple…

  9. Computer-Aided Communication Satellite System Analysis and Optimization.

    ERIC Educational Resources Information Center

    Stagl, Thomas W.; And Others

    Various published computer programs for fixed/broadcast communication satellite system synthesis and optimization are discussed. The rationale for selecting General Dynamics/Convair's Satellite Telecommunication Analysis and Modeling Program (STAMP) in modified form to aid in the system costing and sensitivity analysis work in the Program on…

  10. Computer-aided communication satellite system analysis and optimization

    NASA Technical Reports Server (NTRS)

    Stagl, T. W.; Morgan, N. H.; Morley, R. E.; Singh, J. P.

    1973-01-01

    The capabilities and limitations of the various published computer programs for fixed/broadcast communication satellite system synthesis and optimization are discussed. A satellite Telecommunication analysis and Modeling Program (STAMP) for costing and sensitivity analysis work in application of communication satellites to educational development is given. The modifications made to STAMP include: extension of the six beam capability to eight; addition of generation of multiple beams from a single reflector system with an array of feeds; an improved system costing to reflect the time value of money, growth in earth terminal population with time, and to account for various measures of system reliability; inclusion of a model for scintillation at microwave frequencies in the communication link loss model; and, an updated technological environment.

  11. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, M.S.

    1998-08-18

    A computer system for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments are improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area and sample sequences in another area on a display device. 27 figs.

  12. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, Mark S.

    1999-10-26

    A computer system (1) for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments may be improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area (814) and sample sequences in another area (816) on a display device (3).

  13. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, Mark S.

    1998-08-18

    A computer system for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments are improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area and sample sequences in another area on a display device.

  14. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, Mark S.

    2001-06-05

    A computer system (1) for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments may be improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area (814) and sample sequences in another area (816) on a display device (3).

  15. Computer aided differential diagnosis in emergency situations (CADDIES) system

    SciTech Connect

    NOEL,WILLIAM P.

    2000-03-01

    This report presents an idea for a portable computerized differential diagnosis tool that could be utilized by a health care provider during an emergency situation. This radio frequency, networked, menu driven system would analyze various patient assessment parameters and make recommendations regarding possible diagnoses/treatment options outside the scope of suspicion of the health care provider. This system would serve as a repository for initial epidemiological data and assist the health care provider with spotting emerging trends.

  16. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, Mark S.; Wang, Chunwei; Jevons, Luis C.; Bernhart, Derek H.; Lipshutz, Robert J.

    2004-05-11

    A computer system for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments are improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area and sample sequences in another area on a display device.

  17. Computer-aided visualization and analysis system for sequence evaluation

    DOEpatents

    Chee, Mark S.

    2003-08-19

    A computer system for analyzing nucleic acid sequences is provided. The computer system is used to perform multiple methods for determining unknown bases by analyzing the fluorescence intensities of hybridized nucleic acid probes. The results of individual experiments may be improved by processing nucleic acid sequences together. Comparative analysis of multiple experiments is also provided by displaying reference sequences in one area and sample sequences in another area on a display device.

  18. CATIA - A computer aided design and manufacturing tridimensional system

    NASA Astrophysics Data System (ADS)

    Bernard, F.

    A properietary computer graphics-aided, three-dimensional interactive application (CATIA) design system is described. CATIA employs approximately 100 graphics displays, which are used by some 500 persons engaged in the definition of aircraft structures, structural strength analyses, the kinematic analysis of mobile elements, aerodynamic calculations, the choice of tooling in the machining of aircraft elements, and the programming of robotics. CATIA covers these diverse fields with a single data base. After a description of salient aspects of the system's hardware and software, graphics examples are given of the definition of curves, surfaces, complex volumes, and analytical tasks.

  19. Computer aided optimal design of compressed air energy storage systems

    NASA Astrophysics Data System (ADS)

    Ahrens, F. W.; Sharma, A.; Ragsdell, K. M.

    1980-07-01

    An automated procedure for the design of Compressed Air Energy Storage (CAES) systems is presented. The procedure relies upon modern nonlinear programming algorithms, decomposition theory, and numerical models of the various system components. Two modern optimization methods are employed; BIAS, a Method of Multipliers code and OPT, a Generalized Reduced Gradient code. The procedure is demonstrated by the design of a CAES facility employing the Media, Illinois Galesville aquifer as the reservoir. The methods employed produced significant reduction in capital and operating cost, and in number of aquifer wells required.

  20. A Hypermedia Computer-Aided Parasitology Tutoring System.

    ERIC Educational Resources Information Center

    Theodoropoulos, Georgios; Loumos, Vassili

    A hypermedia tutoring system for teaching parasitology to college students was developed using an object oriented software development tool, Knowledge Pro. The program was designed to meet four objectives: knowledge incorporation, tutoring, indexing of key words for Boolean search, and random generation of quiz questions with instant scoring. The…

  1. A computer-aided drug discovery system for chemistry teaching.

    PubMed

    Gledhill, Robert; Kent, Sarah; Hudson, Brian; Richards, W Graham; Essex, Jonathan W; Frey, Jeremy G

    2006-01-01

    The Schools Malaria Project (http://emalaria.soton.ac.uk/) brings together school students with university researchers in the hunt for a new antimalaria drug. The design challenge being offered to students is to use a distributed drug search and selection system to design potential antimalaria drugs. The system is accessed via a Web interface. This e-science project displays the results of the trials in an accessible manner, giving students an opportunity for discussion and debate both with peers and with the university contacts. The project has been implemented by using distributed computing techniques, spreading computer load over a network of machines that cross institutional boundaries, forming a grid. This provides access to greater computing power and allows a much more complex and detailed formulation of the drug design problem to be tackled for research, teaching, and learning.

  2. Intelligent Embedded Instruction for Computer-Aided Design (CAD) systems

    DTIC Science & Technology

    1988-10-01

    8217 convenience and according to their individual learning preferences. This benefit is extremely valuable for adult professionals whose needs may be highly...solving problems. Adult designers tend to develop their own personal ways of using CAD software which can optimize a system’s use. This ability has been...average age for subjects with more than 1 year of computer experience was 34 whereas those with less than 2 months of experience averaged 41 years old

  3. Graphical Input Methodology for Computer Aided Analysis of Control Systems.

    DTIC Science & Technology

    1979-12-01

    Control Data Corporation (CDC) CYBER series computer (Ref 4,8). It is designed to run as an INTERCOM job under the NOS/BE operating system (Ref 1,3,5,9...19147-3, Contract- 5- -7. Seattle, Washington, Boeing Areospace Company, 1979. 8. Control Data Corporation . Fortran Extended Version 4 Reference...Manual. Pub. No. 614978%0, Revsion D. Sunnyvale,-California: Publications and Graphics n Division, 1978. 9. Control Data Corporation . INTERCOM Version 4

  4. An Interactive Computer Aiding System for Group Decision Making

    DTIC Science & Technology

    1979-05-01

    In addition, system evaluation studies will continue. The specific items of work for the next period include: (1) Operational testing of the color...Aid with other DDF decision aids; and (3) continuation of full scale experimental studies of the Group Decision Aid. The following specific tasks were...experimental studies are in progress at Perceptronics’ California office. The previously completed experimental hypotheses and the CACI-developed scenario

  5. Computer-aided intelligent system for diagnosing pediatric asthma.

    PubMed

    Zolnoori, Maryam; Fazel Zarandi, Mohammad Hossein; Moin, Mostafa; Heidarnezhad, Hassan; Kazemnejad, Anoshirvan

    2012-04-01

    Asthma is a lung chronic inflammatory disorder estimated between 1.4% and 27.1% in different area of the world. Result of various studies show that asthma is usually underdiagnosed especially in developing countries, because of limitations on access to medical specialists and laboratory facilities. In this paper, we report on the development and evaluation of a novel patient-based fuzzy system that promotes the diagnosis method of asthma. The design of this application addresses five critical issues included: 1) modular representation of asthma diagnostic variables regard to patients' perception of the disease, 2) algorithmic approaches conducting inference of diagnosing based on patient's response to questions, 4) front-end mechanism for capturing data from patient, 5) output for both patient and physician regard to asthma possibility. for the system output score (0-10) the efficacy of this system calculated in the study sample included 139 asthmatic patients and 139 non-asthmatic patients (age range 6-18) reinforce the sensitivity of 88% and specificity of 100% for cut off value 0.7.

  6. [PIV: a computer-aided portal image verification system].

    PubMed

    Fu, Weihua; Zhang, Hongzhi; Wu, Jing

    2002-12-01

    Portal image verification (PIV) is one of the key actions in QA procedure for sophisticated accurate radiotherapy. The purpose of this study was to develop a PIV software as a tool for improving the accuracy and visualization of portal field verification and computing field placement errors. PIV was developed in the visual C++ integrated environment under Windows 95 operating system. It can improve visualization by providing tools for image processing and multimode images display. Semi-automatic register methods make verification more accurate than view-box method. It can provide useful quantitative errors for regular fields. PIV is flexible and accurate. It is an effective tool for portal field verification.

  7. Evolution of facility layout requirements and CAD (computer-aided design) system development

    SciTech Connect

    Jones, M. )

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described.

  8. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  9. Analysis of proctor marking accuracy in a computer-aided personalized system of instruction course.

    PubMed

    Martin, Toby L; Pear, Joseph J; Martin, Garry L

    2002-01-01

    In a computer-aided version of Keller's personalized system of instruction (CAPSI), students within a course were assigned by a computer to be proctors for tests. Archived data from a CAPSI-taught behavior modification course were analyzed to assess proctor accuracy in marking answers as correct or incorrect. Overall accuracy was increased by having each test marked independently by two proctors, and was higher on incorrect answers when the degree of incorrectness was larger.

  10. Unit cell-based computer-aided manufacturing system for tissue engineering.

    PubMed

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-03-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.

  11. Computer-aided diagnosis workstation and database system for chest diagnosis based on multihelical CT images

    NASA Astrophysics Data System (ADS)

    Sato, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki; Ohmatsu, Hironobu; Kakinuma, Ryutaro; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2004-04-01

    Lung cancer is the most common cause, accounting for about 20% of all cancer deaths for males in Japan. Myocardial infarction is also known as a most fearful adult disease. Recently, multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for screening examination. This screening examination requires a considerable number of images to be read. It is this time-consuming step that makes the use of multi-helical CT for mass screening. To overcome this problem, our group has developed a computer-aided diagnosis algorithm to automatically detect suspicious regions of lung cancer and coronary calcifications in chest CT images, so far. And in this time, our group has developed a newly computer-aided diagnosis workstation and database. These consist in three. First, it is an image processing system to automatically detect suspicious bronchial regions, pulmonary artery regions, plumonary vein regions and myocardial infarction regions at high speed. Second, they are two 1600 x 1200 matrix black and white liquid crystal monitor. Third, it is a terminal of image storage. These are connected mutually on the network. This makes it much easier to read images, since the 3D image of suspicious regions and shadow of suspicious regions can be displayed simultaneously on two 1600 x 1200 matrix liquid crystal monitor. The experimental results indicate that a newly computer-aided diagnosis workstation and database system can be effectively used in clinical practice to increase the speed and accuracy of routine diagnosis.

  12. Water system modeling for dispatcher training simulators

    SciTech Connect

    Rajagopal, S.; Sigari, P.G. ); Allen, J.E.; Assadian, M. )

    1993-08-01

    This paper addresses the existing need for training dispatchers in the operation of power systems where it involves managing large water systems. The problem formulation and implementation of water system modeling for the Dispatcher Training Simulators (DTS) are presented in this paper. The method systematically builds the water network descriptions. The model periodically calculates the water system flows, storage values, and currently available hydro generation capacities. The model is controllable by the instructor and provides the simulated telemetry of water system data to the control center functions in the DTS. The water system modeling enhances the power system modeling subsystem of the DTS. The method is validated on a large water system and power system data. The results and the benefits of water system modeling are discussed.

  13. Methods and software tools for computer-aided design of the spacecraft guidance, navigation and control systems

    NASA Astrophysics Data System (ADS)

    Somov, Yevgeny; Oparin, Gennady

    2017-01-01

    We shortly present results on development and employment of the software systems for computer-aided design of the spacecraft guidance. navigation and control systems - modeling, synthesis, nonlinear analysis, simulation and graphic mapping of dynamic processes.

  14. Biomedical informatics for computer-aided decision support systems: a survey.

    PubMed

    Belle, Ashwin; Kon, Mark A; Najarian, Kayvan

    2013-01-01

    The volumes of current patient data as well as their complexity make clinical decision making more challenging than ever for physicians and other care givers. This situation calls for the use of biomedical informatics methods to process data and form recommendations and/or predictions to assist such decision makers. The design, implementation, and use of biomedical informatics systems in the form of computer-aided decision support have become essential and widely used over the last two decades. This paper provides a brief review of such systems, their application protocols and methodologies, and the future challenges and directions they suggest.

  15. Biomedical Informatics for Computer-Aided Decision Support Systems: A Survey

    PubMed Central

    Belle, Ashwin; Kon, Mark A.; Najarian, Kayvan

    2013-01-01

    The volumes of current patient data as well as their complexity make clinical decision making more challenging than ever for physicians and other care givers. This situation calls for the use of biomedical informatics methods to process data and form recommendations and/or predictions to assist such decision makers. The design, implementation, and use of biomedical informatics systems in the form of computer-aided decision support have become essential and widely used over the last two decades. This paper provides a brief review of such systems, their application protocols and methodologies, and the future challenges and directions they suggest. PMID:23431259

  16. IDEAS: A multidisciplinary computer-aided conceptual design system for spacecraft

    NASA Technical Reports Server (NTRS)

    Ferebee, M. J., Jr.

    1984-01-01

    During the conceptual development of advanced aerospace vehicles, many compromises must be considered to balance economy and performance of the total system. Subsystem tradeoffs may need to be made in order to satisfy system-sensitive attributes. Due to the increasingly complex nature of aerospace systems, these trade studies have become more difficult and time-consuming to complete and involve interactions of ever-larger numbers of subsystems, components, and performance parameters. The current advances of computer-aided synthesis, modeling and analysis techniques have greatly helped in the evaluation of competing design concepts. Langley Research Center's Space Systems Division is currently engaged in trade studies for a variety of systems which include advanced ground-launched space transportation systems, space-based orbital transfer vehicles, large space antenna concepts and space stations. The need for engineering analysis tools to aid in the rapid synthesis and evaluation of spacecraft has led to the development of the Interactive Design and Evaluation of Advanced Spacecraft (IDEAS) computer-aided design system. The ADEAS system has been used to perform trade studies of competing technologies and requirements in order to pinpoint possible beneficial areas for research and development. IDEAS is presented as a multidisciplinary tool for the analysis of advanced space systems. Capabilities range from model generation and structural and thermal analysis to subsystem synthesis and performance analysis.

  17. Dispatcher Recognition of Stroke Using the National Academy Medical Priority Dispatch System

    PubMed Central

    Buck, Brian H; Starkman, Sidney; Eckstein, Marc; Kidwell, Chelsea S; Haines, Jill; Huang, Rainy; Colby, Daniel; Saver, Jeffrey L

    2009-01-01

    Background Emergency Medical Dispatchers (EMDs) play an important role in optimizing stroke care if they are able to accurately identify calls regarding acute cerebrovascular disease. This study was undertaken to assess the diagnostic accuracy of the current national protocol guiding dispatcher questioning of 911 callers to identify stroke, QA Guide v 11.1 of the National Academy Medical Priority Dispatch System (MPDS). Methods We identified all Los Angeles Fire Department paramedic transports of patients to UCLA Medical Center during the 12 month period from January to December 2005 in a prospectively maintained database. Dispatcher-assigned MPDS codes for each of these patient transports were abstracted from the paramedic run sheets and compared to final hospital discharge diagnosis. Results Among 3474 transported patients, 96 (2.8%) had a final diagnosis of stroke or transient ischemic attack. Dispatchers assigned a code of potential stroke to 44.8% of patients with a final discharge diagnosis of stroke or TIA. Dispatcher identification of stroke showed a sensitivity of 0.41, specificity of 0.96, positive predictive value of 0.45, and negative predictive value of 0.95. Conclusions Dispatcher recognition of stroke calls using the widely employed MPDS algorithm is suboptimal, with failure to identify more than half of stroke patients as likely stroke. Revisions to the current national dispatcher structured interview and complaint identification algorithm for stroke may facilitate more accurate recognition of stroke by EMDs. PMID:19390065

  18. Computer-aided design and distributed system technology development for large space structures

    NASA Technical Reports Server (NTRS)

    Armstrong, Ernest S.; Joshi, Suresh M.

    1986-01-01

    Proposed large space structures have many characteristics that make them difficult to analyze and control. They are highly flexible, with components mathematically modeled by partial differential equations or very large systems of ordinary differential equations. They have many resonant frequencies, typically low and closely spaced. Natural damping may be low and/or improperly modeled. Coupled with stringent operational requirements of orientation, shape control, and vibration suppression, and the inability to perform adequate ground testing, these characteristics present an unconventional identification and control design problem to the systems theorist. Some of the research underway within Langley's Spacecraft Control Branch, Guidance and Control Division aimed at developing theory and algorithms to treat large space structures systems identification and control problems is described. The research areas to be considered are computer-aided design algorithms, and systems identification and control of distributed systems.

  19. Computer-Aided Diagnosis System for Alzheimer's Disease Using Different Discrete Transform Techniques.

    PubMed

    Dessouky, Mohamed M; Elrashidy, Mohamed A; Taha, Taha E; Abdelkader, Hatem M

    2016-05-01

    The different discrete transform techniques such as discrete cosine transform (DCT), discrete sine transform (DST), discrete wavelet transform (DWT), and mel-scale frequency cepstral coefficients (MFCCs) are powerful feature extraction techniques. This article presents a proposed computer-aided diagnosis (CAD) system for extracting the most effective and significant features of Alzheimer's disease (AD) using these different discrete transform techniques and MFCC techniques. Linear support vector machine has been used as a classifier in this article. Experimental results conclude that the proposed CAD system using MFCC technique for AD recognition has a great improvement for the system performance with small number of significant extracted features, as compared with the CAD system based on DCT, DST, DWT, and the hybrid combination methods of the different transform techniques.

  20. The development of expertise using an intelligent computer-aided training system

    NASA Technical Reports Server (NTRS)

    Johnson, Debra Steele

    1991-01-01

    An initial examination was conducted of an Intelligent Tutoring System (ITS) developed for use in industry. The ITS, developed by NASA, simulated a satellite deployment task. More specifically, the PD (Payload Assist Module Deployment)/ICAT (Intelligent Computer Aided Training) System simulated a nominal Payload Assist Module (PAM) deployment. The development of expertise on this task was examined using three Flight Dynamics Officer (FDO) candidates who has no previous experience with this task. The results indicated that performance improved rapidly until Trial 5, followed by more gradual improvements through Trial 12. The performance dimensions measured included performance speed, actions completed, errors, help required, and display fields checked. Suggestions for further refining the software and for deciding when to expose trainees to more difficult task scenarios are discussed. Further, the results provide an initial demonstration of the effectiveness of the PD/ICAT system in training the nominal PAM deployment task and indicate the potential benefits of using ITS's for training other FDO tasks.

  1. Towards Building a Computer Aided Education System for Special Students Using Wearable Sensor Technologies.

    PubMed

    Mehmood, Raja Majid; Lee, Hyo Jong

    2017-02-08

    Human computer interaction is a growing field in terms of helping people in their daily life to improve their living. Especially, people with some disability may need an interface which is more appropriate and compatible with their needs. Our research is focused on similar kinds of problems, such as students with some mental disorder or mood disruption problems. To improve their learning process, an intelligent emotion recognition system is essential which has an ability to recognize the current emotional state of the brain. Nowadays, in special schools, instructors are commonly use some conventional methods for managing special students for educational purposes. In this paper, we proposed a novel computer aided method for instructors at special schools where they can teach special students with the support of our system using wearable technologies.

  2. Computer Aided Diagnostic Support System for Skin Cancer: A Review of Techniques and Algorithms

    PubMed Central

    Masood, Ammara; Al-Jumaily, Adel Ali

    2013-01-01

    Image-based computer aided diagnosis systems have significant potential for screening and early detection of malignant melanoma. We review the state of the art in these systems and examine current practices, problems, and prospects of image acquisition, pre-processing, segmentation, feature extraction and selection, and classification of dermoscopic images. This paper reports statistics and results from the most important implementations reported to date. We compared the performance of several classifiers specifically developed for skin lesion diagnosis and discussed the corresponding findings. Whenever available, indication of various conditions that affect the technique's performance is reported. We suggest a framework for comparative assessment of skin cancer diagnostic models and review the results based on these models. The deficiencies in some of the existing studies are highlighted and suggestions for future research are provided. PMID:24575126

  3. Harnessing Polypharmacology with Computer-Aided Drug Design and Systems Biology.

    PubMed

    Wathieu, Henri; Issa, Naiem T; Byers, Stephen W; Dakshanamurthy, Sivanesan

    2016-01-01

    The ascent of polypharmacology in drug development has many implications for disease therapy, most notably in the efforts of drug discovery, drug repositioning, precision medicine and combination therapy. The single- target approach to drug development has encountered difficulties in predicting drugs that are both clinically efficacious and avoid toxicity. By contrast, polypharmacology offers the possibility of a controlled distribution of effects on a biological system. This review addresses possibilities and bottlenecks in the efficient computational application of polypharmacology. The two major areas we address are the discovery and prediction of multiple protein targets using the tools of computer-aided drug design, and the use of these protein targets in predicting therapeutic potential in the context of biological networks. The successful application of polypharmacology to systems biology and pharmacology has the potential to markedly accelerate the pace of development of novel therapies for multiple diseases, and has implications for the intellectual property landscape, likely requiring targeted changes in patent law.

  4. Towards Building a Computer Aided Education System for Special Students Using Wearable Sensor Technologies

    PubMed Central

    Mehmood, Raja Majid; Lee, Hyo Jong

    2017-01-01

    Human computer interaction is a growing field in terms of helping people in their daily life to improve their living. Especially, people with some disability may need an interface which is more appropriate and compatible with their needs. Our research is focused on similar kinds of problems, such as students with some mental disorder or mood disruption problems. To improve their learning process, an intelligent emotion recognition system is essential which has an ability to recognize the current emotional state of the brain. Nowadays, in special schools, instructors are commonly use some conventional methods for managing special students for educational purposes. In this paper, we proposed a novel computer aided method for instructors at special schools where they can teach special students with the support of our system using wearable technologies. PMID:28208734

  5. Large Advanced Space Systems (LASS) computer-aided design program additions

    NASA Technical Reports Server (NTRS)

    Farrell, C. E.

    1982-01-01

    The LSS preliminary and conceptual design requires extensive iteractive analysis because of the effects of structural, thermal, and control intercoupling. A computer aided design program that will permit integrating and interfacing of required large space system (LSS) analyses is discussed. The primary objective of this program is the implementation of modeling techniques and analysis algorithms that permit interactive design and tradeoff studies of LSS concepts. Eight software modules were added to the program. The existing rigid body controls module was modified to include solar pressure effects. The new model generator modules and appendage synthesizer module are integrated (interfaced) to permit interactive definition and generation of LSS concepts. The mass properties module permits interactive specification of discrete masses and their locations. The other modules permit interactive analysis of orbital transfer requirements, antenna primary beam n, and attitude control requirements.

  6. Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS), phase 1

    NASA Technical Reports Server (NTRS)

    Kim, S.; Lee, J.; Cho, B. H.; Lee, F. C.

    1986-01-01

    The large-signal behaviors of a regulator depend largely on the type of power circuit topology and control. Thus, for maximum flexibility, it is best to develop models for each functional block a independent modules. A regulator can then be configured by collecting appropriate pre-defined modules for each functional block. In order to complete the component model generation for a comprehensive spacecraft power system, the following modules were developed: solar array switching unit and control; shunt regulators; and battery discharger. The capability of each module is demonstrated using a simplified Direct Energy Transfer (DET) system. Large-signal behaviors of solar array power systems were analyzed. Stability of the solar array system operating points with a nonlinear load is analyzed. The state-plane analysis illustrates trajectories of the system operating point under various conditions. Stability and transient responses of the system operating near the solar array's maximum power point are also analyzed. The solar array system mode of operation is described using the DET spacecraft power system. The DET system is simulated for various operating conditions. Transfer of the software program CAMAPPS (Computer Aided Modeling and Analysis of Power Processing Systems) to NASA/GSFC (Goddard Space Flight Center) was accomplished.

  7. Computer-Aided Personalized System of Instruction: An Effective and Economical Method for Short- and Long-Distance Education.

    ERIC Educational Resources Information Center

    Pear, Joseph J.; Kinsner, W.

    1988-01-01

    Describes a computer program based on Keller's Personalized System of Instruction that has been used for on-campus and off-campus teaching by the University of Manitoba. Highlights include electronic mail, student attitudes and roles, costs, suggestions for future research, and examples from computer-aided personalized system of instruction…

  8. Effects of Computer-Aided Personalized System of Instruction in Developing Knowledge and Critical Thinking in Blended Learning Courses

    ERIC Educational Resources Information Center

    Svenningsen, Louis; Pear, Joseph J.

    2011-01-01

    Two experiments were conducted to assess an online version of Keller's personalized system of instruction, called computer-aided personalized system of instruction (CAPSI), as part of a blended learning design with regard to course knowledge and critical thinking development. In Experiment 1, two lecture sections of an introduction to University…

  9. Computer-aided diagnosis system for coronary artery stenosis using a neural network

    NASA Astrophysics Data System (ADS)

    Suzuki, Kenji; Horiba, Isao; Sugie, Noboru; Nanki, Michio

    2001-07-01

    We have developed a new computer-aided diagnosis system for coronary artery stenosis, which can learn medical doctors' clinical experiences and medical knowledge. In order to develop such a system, we have employed a multilayer neural network (NN). The NN has the capability to learn experts' experiences and knowledge. The proposed system consists of (a) automatic vessel tracking, (b) automatically extraction of the edges of the vessel, and (c) estimation of stenosis based on the NN. In order to evaluate the performance of the proposed system, two experiments with the phantoms and clinical images were performed. The stenoses estimated by the proposed system agreed well with not only the stenoses based on the actual measurement of the phantoms but also those diagnosed by a medical specialist from coronary arteriograms. The experimental results have shown that the proposed system has the capability to learn medical doctors' clinical experiences and medical knowledge. The proposed system has been proved to be useful to aid to diagnose coronary artery stenosis.

  10. Effect of a computer-aided diagnosis system on radiologists' performance in grading gliomas with MRI

    PubMed Central

    Hsieh, Kevin Li-Chun; Tsai, Ruei-Je; Teng, Yu-Chuan

    2017-01-01

    The effects of a computer-aided diagnosis (CAD) system based on quantitative intensity features with magnetic resonance (MR) imaging (MRI) were evaluated by examining radiologists' performance in grading gliomas. The acquired MRI database included 71 lower-grade gliomas and 34 glioblastomas. Quantitative image features were extracted from the tumor area and combined in a CAD system to generate a prediction model. The effect of the CAD system was evaluated in a two-stage procedure. First, a radiologist performed a conventional reading. A sequential second reading was determined with a malignancy estimation by the CAD system. Each MR image was regularly read by one radiologist out of a group of three radiologists. The CAD system achieved an accuracy of 87% (91/105), a sensitivity of 79% (27/34), a specificity of 90% (64/71), and an area under the receiver operating characteristic curve (Az) of 0.89. In the evaluation, the radiologists’ Az values significantly improved from 0.81, 0.87, and 0.84 to 0.90, 0.90, and 0.88 with p = 0.0011, 0.0076, and 0.0167, respectively. Based on the MR image features, the proposed CAD system not only performed well in distinguishing glioblastomas from lower-grade gliomas but also provided suggestions about glioma grading to reinforce radiologists’ confidence rating. PMID:28158235

  11. Effect of a computer-aided diagnosis system on radiologists' performance in grading gliomas with MRI.

    PubMed

    Hsieh, Kevin Li-Chun; Tsai, Ruei-Je; Teng, Yu-Chuan; Lo, Chung-Ming

    2017-01-01

    The effects of a computer-aided diagnosis (CAD) system based on quantitative intensity features with magnetic resonance (MR) imaging (MRI) were evaluated by examining radiologists' performance in grading gliomas. The acquired MRI database included 71 lower-grade gliomas and 34 glioblastomas. Quantitative image features were extracted from the tumor area and combined in a CAD system to generate a prediction model. The effect of the CAD system was evaluated in a two-stage procedure. First, a radiologist performed a conventional reading. A sequential second reading was determined with a malignancy estimation by the CAD system. Each MR image was regularly read by one radiologist out of a group of three radiologists. The CAD system achieved an accuracy of 87% (91/105), a sensitivity of 79% (27/34), a specificity of 90% (64/71), and an area under the receiver operating characteristic curve (Az) of 0.89. In the evaluation, the radiologists' Az values significantly improved from 0.81, 0.87, and 0.84 to 0.90, 0.90, and 0.88 with p = 0.0011, 0.0076, and 0.0167, respectively. Based on the MR image features, the proposed CAD system not only performed well in distinguishing glioblastomas from lower-grade gliomas but also provided suggestions about glioma grading to reinforce radiologists' confidence rating.

  12. Computer-aided modelling and analysis of PV systems: a comparative study.

    PubMed

    Koukouvaos, Charalambos; Kandris, Dionisis; Samarakou, Maria

    2014-01-01

    Modern scientific advances have enabled remarkable efficacy for photovoltaic systems with regard to the exploitation of solar energy, boosting them into having a rapidly growing position among the systems developed for the production of renewable energy. However, in many cases the design, analysis, and control of photovoltaic systems are tasks which are quite complex and thus difficult to be carried out. In order to cope with this kind of problems, appropriate software tools have been developed either as standalone products or parts of general purpose software platforms used to model and simulate the generation, transmission, and distribution of solar energy. The utilization of this kind of software tools may be extremely helpful to the successful performance evaluation of energy systems with maximum accuracy and minimum cost in time and effort. The work presented in this paper aims on a first level at the performance analysis of various configurations of photovoltaic systems through computer-aided modelling. On a second level, it provides a comparative evaluation of the credibility of two of the most advanced graphical programming environments, namely, Simulink and LabVIEW, with regard to their application in photovoltaic systems.

  13. Computer-Aided Modelling and Analysis of PV Systems: A Comparative Study

    PubMed Central

    Koukouvaos, Charalambos

    2014-01-01

    Modern scientific advances have enabled remarkable efficacy for photovoltaic systems with regard to the exploitation of solar energy, boosting them into having a rapidly growing position among the systems developed for the production of renewable energy. However, in many cases the design, analysis, and control of photovoltaic systems are tasks which are quite complex and thus difficult to be carried out. In order to cope with this kind of problems, appropriate software tools have been developed either as standalone products or parts of general purpose software platforms used to model and simulate the generation, transmission, and distribution of solar energy. The utilization of this kind of software tools may be extremely helpful to the successful performance evaluation of energy systems with maximum accuracy and minimum cost in time and effort. The work presented in this paper aims on a first level at the performance analysis of various configurations of photovoltaic systems through computer-aided modelling. On a second level, it provides a comparative evaluation of the credibility of two of the most advanced graphical programming environments, namely, Simulink and LabVIEW, with regard to their application in photovoltaic systems. PMID:24772007

  14. Flight evaluation of a computer aided low-altitude helicopter flight guidance system

    NASA Technical Reports Server (NTRS)

    Swenson, Harry N.; Jones, Raymond D.; Clark, Raymond

    1993-01-01

    The Flight Systems Development branch of the U.S. Army's Avionics Research and Development Activity (AVRADA) and NASA Ames Research Center developed for flight testing a Computer Aided Low-Altitude Helicopter Flight (CALAHF) guidance system. The system includes a trajectory-generation algorithm which uses dynamic programming and a helmet-mounted display (HMD) presentation of a pathway-in-the-sky, a phantom aircraft, and flight-path vector/predictor guidance symbology. The trajectory-generation algorithm uses knowledge of the global mission requirements, a digital terrain map, aircraft performance capabilities, and precision navigation information to determine a trajectory between mission waypoints that seeks valleys to minimize threat exposure. This system was developed and evaluated through extensive use of piloted simulation and has demonstrated a 'pilot centered' concept of automated and integrated navigation and terrain mission planning flight guidance. This system has shown a significant improvement in pilot situational awareness, and mission effectiveness as well as a decrease in training and proficiency time required for a near terrain, nighttime, adverse weather system.

  15. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2007-03-01

    Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.

  16. Computer-aided bone age assessment for ethnically diverse older children using integrated fuzzy logic system

    NASA Astrophysics Data System (ADS)

    Ma, Kevin; Moin, Paymann; Zhang, Aifeng; Liu, Brent

    2010-03-01

    Bone Age Assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on the left hand x-ray radiograph. The current BAA standard in the US is using the Greulich & Pyle (G&P) Hand Atlas, which was developed fifty years ago and was only based on Caucasian population from the Midwest US. To bring the BAA procedure up-to-date with today's population, a Digital Hand Atlas (DHA) consisting of 1400 hand images of normal children of different ethnicities, age, and gender. Based on the DHA and to solve inter- and intra-observer reading discrepancies, an automatic computer-aided bone age assessment system has been developed and tested in clinical environments. The algorithm utilizes features extracted from three regions of interests: phalanges, carpal, and radius. The features are aggregated into a fuzzy logic system, which outputs the calculated bone age. The previous BAA system only uses features from phalanges and carpal, thus BAA result for children over age of 15 is less accurate. In this project, the new radius features are incorporated into the overall BAA system. The bone age results, calculated from the new fuzzy logic system, are compared against radiologists' readings based on G&P atlas, and exhibits an improvement in reading accuracy for older children.

  17. Computer-aided system for measuring the mandibular cortical width on panoramic radiographs in osteoporosis diagnosis

    NASA Astrophysics Data System (ADS)

    Arifin, Agus Zainal; Asano, Akira; Taguchi, Akira; Nakamoto, Takashi; Ohtsuka, Masahiko; Tanimoto, Keiji

    2005-04-01

    Osteoporotic fractures are associated with substantial morbidity, increased medical cost and high mortality risk. Several equipments of bone assessment have been developed to identify individuals, especially postmenopausal women, with high risk of osteoporotic fracture; however, a large segment of women with low skeletal bone mineral density (BMD), namely women with high risk of osteoporotic fractures, cannot be identified sufficiently because osteoporosis is asymptomatic. Recent studies have been demonstrating that mandibular inferior cortical width manually measured on panoramic radiographs may be useful for the identification of women with low BMD. Automatic measurement of cortical width may enable us to identify a large number of asymptomatic women with low BMD. The purpose of this study was to develop a computer-aided system for measuring the mandibular cortical width on panoramic radiographs. Initially, oral radiologists determined the region of interest based on the position of mental foramen. Some enhancing image techniques were applied so as to measure the cortical width at the best point. Panoramic radiographs of 100 women who had BMD assessments of the lumbar spine and femoral neck were used to confirm the efficacy of our new system. Cortical width measured with our system was compared with skeletal BMD. There were significant correlation between cortical width measured with our system and skeletal BMD. These correlations were similar with those between cortical width manually measured by the dentist and skeletal BMD. Our results suggest that our new system may be useful for mass screening of osteoporosis.

  18. Straddle Carrier Interface and Dispatching System

    SciTech Connect

    2012-09-13

    SCIDS is the Data Dispatching and Transfer Point (DDTP) component of a straddle carrier-based radiation detection system developed for the DOE Megaports Initiative for scanning shipping containers in transshipment ports. Its purpose is to communicate with a Radiation Detection Straddle Carrier (RDSC) developed by Detector Networks International, sending commands to the RDSC and receiving sensor data from the RDSC. Incoming sensor and status data from the RDSC is forwarded to a back-end data storage and display system that is external to SCIDS. SCIDS provides a graphical user interface for port operations personnel that displays location and status of the RDSC and status of each container in the port, and accepts commands from the operator directing the scanning operations of the RDSC.

  19. Computer-aided design of control systems to meet many requirements

    NASA Technical Reports Server (NTRS)

    Schy, A. A.; Adams, W. M., Jr.; Johnson, K. G.

    1974-01-01

    A method is described for using nonlinear programing in the computer-aided design of airplane control systems. It is assumed that the quality of such systems depends on many criteria. These criteria are included in the constraints vector (instead of attempting to combine them into a single scalar criterion, as is usually done), and the design proceeds through a sequence of nonlinear programing solutions in which the designer varies the specification of sets of requirements levels. The method is applied to design of a lateral stability augmentation system (SAS) for a fighter airplane, in which the requirements vector is chosen from the official handling qualities specifications. Results are shown for several simple SAS configurations designed to obtain desirable handling qualities over all design flight conditions with minimum feedback gains. The choice of the final design for each case is not unique but depends on the designer's decision as to which achievable set of requirements levels represents the best for that system. Results indicate that it may be possible to design constant parameter SAS which can satisfy the most stringent handling qualities requirements for fighter airplanes in all flight conditions. The role of the designer as a decision maker, interacting with the computer program, is discussed. Advantages of this type of designer-computer interaction are emphasized. Desirable extensions of the method are indicated.

  20. Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies

    PubMed Central

    El-Baz, Ayman; Beache, Garth M.; Gimel'farb, Georgy; Suzuki, Kenji; Okada, Kazunori; Elnakib, Ahmed; Soliman, Ahmed; Abdollahi, Behnoush

    2013-01-01

    This paper overviews one of the most important, interesting, and challenging problems in oncology, the problem of lung cancer diagnosis. Developing an effective computer-aided diagnosis (CAD) system for lung cancer is of great clinical importance and can increase the patient's chance of survival. For this reason, CAD systems for lung cancer have been investigated in a huge number of research studies. A typical CAD system for lung cancer diagnosis is composed of four main processing steps: segmentation of the lung fields, detection of nodules inside the lung fields, segmentation of the detected nodules, and diagnosis of the nodules as benign or malignant. This paper overviews the current state-of-the-art techniques that have been developed to implement each of these CAD processing steps. For each technique, various aspects of technical issues, implemented methodologies, training and testing databases, and validation methods, as well as achieved performances, are described. In addition, the paper addresses several challenges that researchers face in each implementation step and outlines the strengths and drawbacks of the existing approaches for lung cancer CAD systems. PMID:23431282

  1. A Computer-Aided Telephone System to Enable Five Persons with Alzheimer's Disease to Make Phone Calls Independently

    ERIC Educational Resources Information Center

    Perilli, Viviana; Lancioni, Giulio E.; Laporta, Dominga; Paparella, Adele; Caffo, Alessandro O.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Oliva, Doretta

    2013-01-01

    This study extended the assessment of a computer-aided telephone system to enable five patients with a diagnosis of Alzheimer's disease to make phone calls independently. The patients were divided into two groups and exposed to intervention according to a non-concurrent multiple baseline design across groups. All patients started with baseline in…

  2. Computer-aided detection of breast masses on mammograms: performance improvement using a dual system

    NASA Astrophysics Data System (ADS)

    Wei, Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Helvie, Mark A.; Roubidoux, Marilyn A.; Petrick, Nicholas; Ge, Jun; Zhou, Chuan

    2005-04-01

    We have developed a computer-aided detection (CAD) system for breast masses on mammograms. In this study, our purpose was to improve the performance of our mass detection system by using a new dual system approach which combines a CAD system optimized with "average" masses with another CAD system optimized with subtle masses. The latter system is trained to provide high sensitivity in detecting subtle masses. For an unknown mammogram, the two systems are used in parallel to detect suspicious objects. A feed-forward backpropagation neural network trained to merge the scores of the two linear discriminant analysis (LDA) classifiers from the two systems makes the final decision in differentiation of true masses from normal tissue. A data set of 86 patients containing 172 mammograms with biopsy-proven masses was partitioned into a training set and an independent test set. This data set is referred to as the average data set. A second data set of 214 prior mammograms was used for training the second CAD system for detection of subtle masses. When the single CAD system trained on the average data set was applied to the test set, the Az for false positive (FP) classification was 0.81 and the FP rates were 2.1, 1.5 and 1.3 FPs/image at the case-based sensitivities of 95%, 90% and 85%, respectively. With the dual CAD system, the Az was 0.85 and the FP rates were improved to 1.7, 1.2 and 0.8 FPs/image at the same case-based sensitivities. Our results indicate that the dual CAD system can improve the performance of mass detection on mammograms.

  3. Flight evaluation of a computer aided low-altitude helicopter flight guidance system

    NASA Technical Reports Server (NTRS)

    Swenson, Harry N.; Jones, Raymond D.; Clark, Raymond

    1993-01-01

    The Flight Systems Development branch of the U.S. Army's Avionics Research and Development Activity (AVRADA) and NASA Ames Research Center have developed for flight testing a Computer Aided Low-Altitude Helicopter Flight (CALAHF) guidance system. The system includes a trajectory-generation algorithm which uses dynamic programming and a helmet-mounted display (HMD) presentation of a pathway-in-the-sky, a phantom aircraft, and flight-path vector/predictor guidance symbology. The trajectory-generation algorithm uses knowledge of the global mission requirements, a digital terrain map, aircraft performance capabilities, and precision navigation information to determine a trajectory between mission way points that seeks valleys to minimize threat exposure. This system was developed and evaluated through extensive use of piloted simulation and has demonstrated a 'pilot centered' concept of automated and integrated navigation and terrain mission planning flight guidance. This system has shown a significant improvement in pilot situational awareness, and mission effectiveness as well as a decrease in training and proficiency time required for a near terrain, nighttime, adverse weather system. AVRADA's NUH-60A STAR (Systems Testbed for Avionics Research) helicopter was specially modified, in house, for the flight evaluation of the CALAHF system. The near terrain trajectory generation algorithm runs on a multiprocessor flight computer. Global Positioning System (GPS) data are integrated with Inertial Navigation Unit (INU) data in the flight computer to provide a precise navigation solution. The near-terrain trajectory and the aircraft state information are passed to a Silicon Graphics computer to provide the graphical 'pilot centered' guidance, presented on a Honeywell Integrated Helmet And Display Sighting System (IHADSS). The system design, piloted simulation, and initial flight test results are presented.

  4. CATOS (Computer Aided Training/Observing System): Automating animal observation and training.

    PubMed

    Oh, Jinook; Fitch, W Tecumseh

    2017-02-01

    In animal behavioral biology, an automated observing/training system may be useful for several reasons: (a) continuous observation of animals for documentation of specific, irregular events, (b) long-term intensive training of animals in preparation for behavioral experiments, (c) elimination of potential cues and biases induced by humans during training and testing. Here, we describe an open-source-based system named CATOS (Computer Aided Training/Observing System) developed for such situations. There are several notable features in this system. CATOS is flexible and low cost because it is based on free open-source software libraries, common hardware parts, and open-system electronics based on Arduino. Automated video condensation is applied, leading to significantly reduced video data storage compared to the total active hours of the system. A data-viewing utility program helps a user browse recorded data quickly and more efficiently. With these features, CATOS has the potential to be applied to many different animal species in various environments such as laboratories, zoos, or even private homes. Also, an animal's free access to the device without constraint, and a gamified learning process, enhance the animal's welfare and enriches their environment. As a proof of concept, the system was built and tested with two different species. Initially, the system was tested for approximately 10 months with a domesticated cat. The cat was successfully and fully automatically trained to discriminate three different spoken words. Then, in order to test the system's adaptability to other species and hardware components, we used it to train a laboratory rat for 3 weeks.

  5. Utilization of computer-aided detection system in diagnosing unilateral maxillary sinusitis on panoramic radiographs

    PubMed Central

    Ohashi, Yasufumi; Katsumata, Akitoshi; Fujita, Hiroshi; Nakayama, Miwa; Fukuda, Motoki; Nozawa, Michihito; Ariji, Eiichiro

    2016-01-01

    Objectives: It is unclear whether computer-aided detection (CAD) systems for panoramic radiography can help inexperienced dentists to diagnose maxillary sinusitis. The aim of this study was to clarify whether a CAD system for panoramic radiography can contribute to improved diagnostic performance for maxillary sinusitis by inexperienced dentists. Methods: The panoramic radiographs of 49 patients with maxillary sinusitis and 49 patients with healthy sinuses were evaluated in this study. The diagnostic performance of the CAD system was determined. 12 inexperienced dentists and 4 expert oral and maxillofacial radiologists observed the total of 98 panoramic radiographs and judged the presence or absence of maxillary sinusitis, under conditions with and without the support of the CAD system. The receiver operating characteristic curves of the two groups were compared. Results: The CAD system provided sensitivity of 77.6%, specificity of 69.4% and accuracy of 73.5%. The diagnostic performance of the inexperienced dentists increased with the support of the CAD system. When the inexperienced dentists diagnosed maxillary sinusitis with CAD support, the area under the curve (AUC) was significantly higher than that without CAD support. When the focus was only on panoramic radiographs in which CAD support led to a correct diagnosis, the AUC of the inexperienced dentists increased to an equivalent level to that of the experienced radiologists. Conclusions: The CAD system supported the inexperienced dentists in diagnosing maxillary sinusitis on the panoramic radiographs. If the accuracy of the CAD system can be increased, the benefits of CAD support will be further enhanced. PMID:26837670

  6. Computer-aided detection system for lung cancer in computed tomography scans: Review and future prospects

    PubMed Central

    2014-01-01

    Introduction The goal of this paper is to present a critical review of major Computer-Aided Detection systems (CADe) for lung cancer in order to identify challenges for future research. CADe systems must meet the following requirements: improve the performance of radiologists providing high sensitivity in the diagnosis, a low number of false positives (FP), have high processing speed, present high level of automation, low cost (of implementation, training, support and maintenance), the ability to detect different types and shapes of nodules, and software security assurance. Methods The relevant literature related to “CADe for lung cancer” was obtained from PubMed, IEEEXplore and Science Direct database. Articles published from 2009 to 2013, and some articles previously published, were used. A systemic analysis was made on these articles and the results were summarized. Discussion Based on literature search, it was observed that many if not all systems described in this survey have the potential to be important in clinical practice. However, no significant improvement was observed in sensitivity, number of false positives, level of automation and ability to detect different types and shapes of nodules in the studied period. Challenges were presented for future research. Conclusions Further research is needed to improve existing systems and propose new solutions. For this, we believe that collaborative efforts through the creation of open source software communities are necessary to develop a CADe system with all the requirements mentioned and with a short development cycle. In addition, future CADe systems should improve the level of automation, through integration with picture archiving and communication systems (PACS) and the electronic record of the patient, decrease the number of false positives, measure the evolution of tumors, evaluate the evolution of the oncological treatment, and its possible prognosis. PMID:24713067

  7. Computer-Aided System Engineering and Analysis (CASE/A) Programmer's Manual, Version 5.0

    NASA Technical Reports Server (NTRS)

    Knox, J. C.

    1996-01-01

    The Computer Aided System Engineering and Analysis (CASE/A) Version 5.0 Programmer's Manual provides the programmer and user with information regarding the internal structure of the CASE/A 5.0 software system. CASE/A 5.0 is a trade study tool that provides modeling/simulation capabilities for analyzing environmental control and life support systems and active thermal control systems. CASE/A has been successfully used in studies such as the evaluation of carbon dioxide removal in the space station. CASE/A modeling provides a graphical and command-driven interface for the user. This interface allows the user to construct a model by placing equipment components in a graphical layout of the system hardware, then connect the components via flow streams and define their operating parameters. Once the equipment is placed, the simulation time and other control parameters can be set to run the simulation based on the model constructed. After completion of the simulation, graphical plots or text files can be obtained for evaluation of the simulation results over time. Additionally, users have the capability to control the simulation and extract information at various times in the simulation (e.g., control equipment operating parameters over the simulation time or extract plot data) by using "User Operations (OPS) Code." This OPS code is written in FORTRAN with a canned set of utility subroutines for performing common tasks. CASE/A version 5.0 software runs under the VAX VMS(Trademark) environment. It utilizes the Tektronics 4014(Trademark) graphics display system and the VTIOO(Trademark) text manipulation/display system.

  8. Impact of Computer-Aided Detection Systems on Radiologist Accuracy With Digital Mammography

    PubMed Central

    Cole, Elodia B.; Zhang, Zheng; Marques, Helga S.; Hendrick, R. Edward; Yaffe, Martin J.; Pisano, Etta D.

    2014-01-01

    OBJECTIVE The purpose of this study was to assess the impact of computer-aided detection (CAD) systems on the performance of radiologists with digital mammograms acquired during the Digital Mammographic Imaging Screening Trial (DMIST). MATERIALS AND METHODS Only those DMIST cases with proven cancer status by biopsy or 1-year follow-up that had available digital images were included in this multireader, multicase ROC study. Two commercially available CAD systems for digital mammography were used: iCAD SecondLook, version 1.4; and R2 ImageChecker Cenova, version 1.0. Fourteen radiologists interpreted, without and with CAD, a set of 300 cases (150 cancer, 150 benign or normal) on the iCAD SecondLook system, and 15 radiologists interpreted a different set of 300 cases (150 cancer, 150 benign or normal) on the R2 ImageChecker Cenova system. RESULTS The average AUC was 0.71 (95% CI, 0.66–0.76) without and 0.72 (95% CI, 0.67–0.77) with the iCAD system (p = 0.07). Similarly, the average AUC was 0.71 (95% CI, 0.66–0.76) without and 0.72 (95% CI 0.67–0.77) with the R2 system (p = 0.08). Sensitivity and specificity differences without and with CAD for both systems also were not significant. CONCLUSION Radiologists in our studies rarely changed their diagnostic decisions after the addition of CAD. The application of CAD had no statistically significant effect on radiologist AUC, sensitivity, or specificity performance with digital mammograms from DMIST. PMID:25247960

  9. Modeling uncertainty in classification design of a computer-aided detection system

    NASA Astrophysics Data System (ADS)

    Hosseini, Rahil; Dehmeshki, Jamshid; Barman, Sarah; Mazinani, Mahdi; Qanadli, Salah

    2010-03-01

    A computerized image analysis technology suffers from imperfection, imprecision and vagueness of the input data and its propagation in all individual components of the technology including image enhancement, segmentation and pattern recognition. Furthermore, a Computerized Medical Image Analysis System (CMIAS) such as computer aided detection (CAD) technology deals with another source of uncertainty that is inherent in image-based practice of medicine. While there are several technology-oriented studies reported in developing CAD applications, no attempt has been made to address, model and integrate these types of uncertainty in the design of the system components, even though uncertainty issues directly affect the performance and its accuracy. In this paper, the main uncertainty paradigms associated with CAD technologies are addressed. The influence of the vagueness and imprecision in the classification of the CAD, as a second reader, on the validity of ROC analysis results is defined. In order to tackle the problem of uncertainty in the classification design of the CAD, two fuzzy methods are applied and evaluated for a lung nodule CAD application. Type-1 fuzzy logic system (T1FLS) and an extension of it, interval type-2 fuzzy logic system (IT2FLS) are employed as methods with high potential for managing uncertainty issues. The novelty of the proposed classification methods is to address and handle all sources of uncertainty associated with a CAD system. The results reveal that IT2FLS is superior to T1FLS for tackling all sources of uncertainty and significantly, the problem of inter and intra operator observer variability.

  10. A computer aided diagnosis system for thyroid disease using extreme learning machine.

    PubMed

    Li, Li-Na; Ouyang, Ji-Hong; Chen, Hui-Ling; Liu, Da-You

    2012-10-01

    In this paper, we present an effective and efficient computer aided diagnosis (CAD) system based on principle component analysis (PCA) and extreme learning machine (ELM) to assist the task of thyroid disease diagnosis. The CAD system is comprised of three stages. Focusing on dimension reduction, the first stage applies PCA to construct the most discriminative new feature set. After then, the system switches to the second stage whose target is model construction. ELM classifier is explored to train an optimal predictive model whose parameters are optimized. As we known, the number of hidden neurons has an important role in the performance of ELM, so we propose an experimental method to hunt for the optimal value. Finally, the obtained optimal ELM model proceeds to perform the thyroid disease diagnosis tasks using the most discriminative new feature set and the optimal parameters. The effectiveness of the resultant CAD system (PCA-ELM) has been rigorously estimated on a thyroid disease dataset which is taken from UCI machine learning repository. We compare it with other related methods in terms of their classification accuracy. Experimental results demonstrate that PCA-ELM outperforms other ones reported so far by 10-fold cross-validation method, with the mean accuracy of 97.73% and with the maximum accuracy of 98.1%. Besides, PCA-ELM performs much faster than support vector machines (SVM) based CAD system. Consequently, the proposed method PCA-ELM can be considered as a new powerful tools for diagnosing thyroid disease with excellent performance and less time.

  11. An interactive system for computer-aided diagnosis of breast masses.

    PubMed

    Wang, Xingwei; Li, Lihua; Liu, Wei; Xu, Weidong; Lederman, Dror; Zheng, Bin

    2012-10-01

    Although mammography is the only clinically accepted imaging modality for screening the general population to detect breast cancer, interpreting mammograms is difficult with lower sensitivity and specificity. To provide radiologists "a visual aid" in interpreting mammograms, we developed and tested an interactive system for computer-aided detection and diagnosis (CAD) of mass-like cancers. Using this system, an observer can view CAD-cued mass regions depicted on one image and then query any suspicious regions (either cued or not cued by CAD). CAD scheme automatically segments the suspicious region or accepts manually defined region and computes a set of image features. Using content-based image retrieval (CBIR) algorithm, CAD searches for a set of reference images depicting "abnormalities" similar to the queried region. Based on image retrieval results and a decision algorithm, a classification score is assigned to the queried region. In this study, a reference database with 1,800 malignant mass regions and 1,800 benign and CAD-generated false-positive regions was used. A modified CBIR algorithm with a new function of stretching the attributes in the multi-dimensional space and decision scheme was optimized using a genetic algorithm. Using a leave-one-out testing method to classify suspicious mass regions, we compared the classification performance using two CBIR algorithms with either equally weighted or optimally stretched attributes. Using the modified CBIR algorithm, the area under receiver operating characteristic curve was significantly increased from 0.865 ± 0.006 to 0.897 ± 0.005 (p < 0.001). This study demonstrated the feasibility of developing an interactive CAD system with a large reference database and achieving improved performance.

  12. Multi-Input/Multi-Output Designated Eigenstructure (MODES): A Computer-Aided Control System Design Program.

    DTIC Science & Technology

    1987-03-01

    must. introduce some tools. The first of these is known as Newton’s Formulas ( Uspensky , 1948: 261). oA 4-32 ’ */ Newton’s Formulas relate the...Academic Press, Inc., 1976. Uspensky , J.V. Theory of Equations. New York: McGraw- Hill Book Company, 1948. Walker, Robert A., et al. "Computer-Aided

  13. CASTLE3D - A Computer Aided System for Labelling Archaeological Excavations in 3D

    NASA Astrophysics Data System (ADS)

    Houshiar, H.; Borrmann, D.; Elseberg, J.; Nüchter, A.; Näth, F.; Winkler, S.

    2015-08-01

    Documentation of archaeological excavation sites with conventional methods and tools such as hand drawings, measuring tape and archaeological notes is time consuming. This process is prone to human errors and the quality of the documentation depends on the qualification of the archaeologist on site. Use of modern technology and methods in 3D surveying and 3D robotics facilitate and improve this process. Computer-aided systems and databases improve the documentation quality and increase the speed of data acquisition. 3D laser scanning is the state of the art in modelling archaeological excavation sites, historical sites and even entire cities or landscapes. Modern laser scanners are capable of data acquisition of up to 1 million points per second. This provides a very detailed 3D point cloud of the environment. 3D point clouds and 3D models of an excavation site provide a better representation of the environment for the archaeologist and for documentation. The point cloud can be used both for further studies on the excavation and for the presentation of results. This paper introduces a Computer aided system for labelling archaeological excavations in 3D (CASTLE3D). Consisting of a set of tools for recording and georeferencing the 3D data from an excavation site, CASTLE3D is a novel documentation approach in industrial archaeology. It provides a 2D and 3D visualisation of the data and an easy-to-use interface that enables the archaeologist to select regions of interest and to interact with the data in both representations. The 2D visualisation and a 3D orthogonal view of the data provide cuts of the environment that resemble the traditional hand drawings. The 3D perspective view gives a realistic view of the environment. CASTLE3D is designed as an easy-to-use on-site semantic mapping tool for archaeologists. Each project contains a predefined set of semantic information that can be used to label findings in the data. Multiple regions of interest can be joined under

  14. Hybrid robust predictive optimization method of power system dispatch

    DOEpatents

    Chandra, Ramu Sharat; Liu, Yan; Bose, Sumit; de Bedout, Juan Manuel

    2011-08-02

    A method of power system dispatch control solves power system dispatch problems by integrating a larger variety of generation, load and storage assets, including without limitation, combined heat and power (CHP) units, renewable generation with forecasting, controllable loads, electric, thermal and water energy storage. The method employs a predictive algorithm to dynamically schedule different assets in order to achieve global optimization and maintain the system normal operation.

  15. A novel computer-aided detection system for pulmonary nodule identification in CT images

    NASA Astrophysics Data System (ADS)

    Han, Hao; Li, Lihong; Wang, Huafeng; Zhang, Hao; Moore, William; Liang, Zhengrong

    2014-03-01

    Computer-aided detection (CADe) of pulmonary nodules from computer tomography (CT) scans is critical for assisting radiologists to identify lung lesions at an early stage. In this paper, we propose a novel approach for CADe of lung nodules using a two-stage vector quantization (VQ) scheme. The first-stage VQ aims to extract lung from the chest volume, while the second-stage VQ is designed to extract initial nodule candidates (INCs) within the lung volume. Then rule-based expert filtering is employed to prune obvious FPs from INCs, and the commonly-used support vector machine (SVM) classifier is adopted to further reduce the FPs. The proposed system was validated on 100 CT scans randomly selected from the 262 scans that have at least one juxta-pleural nodule annotation in the publicly available database - Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI). The two-stage VQ only missed 2 out of the 207 nodules at agreement level 1, and the INCs detection for each scan took about 30 seconds in average. Expert filtering reduced FPs more than 18 times, while maintaining a sensitivity of 93.24%. As it is trivial to distinguish INCs attached to pleural wall versus not on wall, we investigated the feasibility of training different SVM classifiers to further reduce FPs from these two kinds of INCs. Experiment results indicated that SVM classification over the entire set of INCs was in favor of, where the optimal operating of our CADe system achieved a sensitivity of 89.4% at a specificity of 86.8%.

  16. Development of a Computer-Aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2007-06-01

    system (C) Development of image processing techniques for improvement of mass detection on prior mammograms ( D ) Continue to develop a two-view...increase the overall accuracy for detection of subtle early-stage breast cancers. 13 ( D ) Continuation of Development of a Two-view Information Fusion...Petrick, B. Sahiner, S. C. B. Lo, M. Freedman, D . Adler, J. Bailey, et al., "Sensitivity of noncommercial computer-aided detection system for

  17. Validation of a computer-aided diagnosis system for the automatic identification of carotid atherosclerosis.

    PubMed

    Bonanno, Lilla; Marino, Silvia; Bramanti, Placido; Sottile, Fabrizio

    2015-02-01

    Carotid atherosclerosis represents one of the most important causes of brain stroke. The degree of carotid stenosis is, up to now, considered one of the most important features for determining the risk of brain stroke. Ultrasound (US) is a non-invasive, relatively inexpensive, portable technique, which has an excellent temporal resolution. Computer-aided diagnosis (CAD) has become one of the major research fields in medical and diagnostic imaging. We studied US images of 44 patients, 22 patients with and 22 without carotid artery stenosis, by using US examination and applying a CAD system, an automatic prototype software to detect carotid plaques. We obtained 287 regions: 60 were classified as plaques, with an average signal echogenicity of 244.1 ± 20.0 and 227 were classified as non-plaques, with an average signal echogenicity of 193.8 ± 38.6 compared with the opinion of an expert neurologist (golden test). The receiver operating characteristic (ROC) analysis revealed a highly significant area under the ROC curve difference from 0.5 (null hypothesis) in the discrimination between plaques and non-plaques; the diagnostic accuracy was 89% (95% CI: 0.85-0.92), with an appropriate cut-off value of 236.8, sensitivity was 83% and specificity reached a value of 85%. The experimental results showed that the proposed method is feasible and has a good agreement with the expert neurologist. Without the need of any user-interaction, this method generates a detection out-put that may be useful in second opinion.

  18. A computer-aided diagnosis system to detect pathologies in temporal subtraction images of chest radiographs

    NASA Astrophysics Data System (ADS)

    Looper, Jared; Harrison, Melanie; Armato, Samuel G.

    2016-03-01

    Radiologists often compare sequential radiographs to identify areas of pathologic change; however, this process is prone to error, as human anatomy can obscure the regions of change, causing the radiologists to overlook pathology. Temporal subtraction (TS) images can provide enhanced visualization of regions of change in sequential radiographs and allow radiologists to better detect areas of change in radiographs. Not all areas of change shown in TS images, however, are actual pathology. The purpose of this study was to create a computer-aided diagnostic (CAD) system that identifies which regions of change are caused by pathology and which are caused by misregistration of the radiographs used to create the TS image. The dataset used in this study contained 120 images with 74 pathologic regions on 54 images outlined by an experienced radiologist. High and low ("light" and "dark") gray-level candidate regions were extracted from the images using gray-level thresholding. Then, sampling techniques were used to address the class imbalance problem between "true" and "false" candidate regions. Next, the datasets of light candidate regions, dark candidate regions, and the combined set of light and dark candidate regions were used as training and testing data for classifiers by using five-fold cross validation. Of the classifiers tested (support vector machines, discriminant analyses, logistic regression, and k-nearest neighbors), the support vector machine on the combined candidates using synthetic minority oversampling technique (SMOTE) performed best with an area under the receiver operating characteristic curve value of 0.85, a sensitivity of 85%, and a specificity of 84%.

  19. A novel computer-aided lung nodule detection system for CT images

    SciTech Connect

    Tan, Maxine; Deklerck, Rudi; Jansen, Bart; Bister, Michel; Cornelis, Jan

    2011-10-15

    Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items

  20. Computer Aided Detection (CAD) Systems for Mammography and the Use of GRID in Medicine

    NASA Astrophysics Data System (ADS)

    Lauria, Adele

    It is well known that the most effective way to defeat breast cancer is early detection, as surgery and medical therapies are more efficient when the disease is diagnosed at an early stage. The principal diagnostic technique for breast cancer detection is X-ray mammography. Screening programs have been introduced in many European countries to invite women to have periodic radiological breast examinations. In such screenings, radiologists are often required to examine large numbers of mammograms with a double reading, that is, two radiologists examine the images independently and then compare their results. In this way an increment in sensitivity (the rate of correctly identified images with a lesion) of up to 15% is obtained.1,2 In most radiological centres, it is a rarity to find two radiologists to examine each report. In recent years different Computer Aided Detection (CAD) systems have been developed as a support to radiologists working in mammography: one may hope that the "second opinion" provided by CAD might represent a lower cost alternative to improve the diagnosis. At present, four CAD systems have obtained the FDA approval in the USA. † Studies3,4 show an increment in sensitivity when CAD systems are used. Freer and Ulissey in 2001 5 demonstrated that the use of a commercial CAD system (ImageChecker M1000, R2 Technology) increases the number of cancers detected up to 19.5% with little increment in recall rate. Ciatto et al.,5 in a study simulating a double reading with a commercial CAD system (SecondLook‡), showed a moderate increment in sensitivity while reducing specificity (the rate of correctly identified images without a lesion). Notwithstanding these optimistic results, there is an ongoing debate to define the advantages of the use of CAD as second reader: the main limits underlined, e.g., by Nishikawa6 are that retrospective studies are considered much too optimistic and that clinical studies must be performed to demonstrate a statistically

  1. Clinical application of a novel computer-aided detection system based on three-dimensional CT images on pulmonary nodule.

    PubMed

    Zeng, Jian-Ye; Ye, Hai-Hong; Yang, Shi-Xiong; Jin, Ren-Chao; Huang, Qi-Liang; Wei, Yong-Chu; Huang, Si-Guang; Wang, Bin-Qiang; Ye, Jia-Zhou; Qin, Jian-Ying

    2015-01-01

    The aim of this study was to investigate the clinical application effects of a novel computer-aided detection (CAD) system based on three-dimensional computed tomography (CT) images on pulmonary nodule. 98 cases with pulmonary nodule (PN) in our hospital from Jun, 2009 to Jun, 2013 were analysed in this study. All cases underwent PN detection both by the simple spiral CT scan and by the computer-aided system based on 3D CT images, respectively. Postoperative pathological results were considered as the "gold standard", for both two checking methods, the diagnostic accuracies for determining benign and malignant PN were calculated. Under simple spiral CT scan method, 63 cases is malignant, including 50 true positive cases and 13 false positive cases from the "gold standard"; 35 cases is benign, 16 true negative case and 19 false negative cases, the Sensitivity 1 (Se1)=0.725, Specificity1 (Sp1)=0.448, Agreement rate1 (Kappa 1)=0.673, J1 (Youden's index 1)=0.173, LR(+)1=1.616, LR(-)1=0.499. Kappa 1=0.673 between the 0.4 and 0.75, has a moderate consistency. Underwent computer-aided detection (CAD) based on 3D CT method, 67cases is malignant, including 62 true positive cases and 7 false positive cases; 31 cases is benign, 24 true negative case and 7 false negative cases, Sensitivity 2 (Se2)=0.899, Specificity2 (Sp2)=0.828, Agreement rate (Kappa 2)=0.877, J2 (Youden's index 2)=0.727, LR(+)2=5.212, LR(-)2=0.123. Kappa 2=0.877 >0.75, has a good consistency. Computer-aided PN detecting system based on 3D CT images has better clinical application value, and can help doctor carry out early diagnosis of lung disease (such as cancer, etc.) through CT images.

  2. Quality assurance and training procedures for computer-aided detection and diagnosis systems in clinical use.

    PubMed

    Huo, Zhimin; Summers, Ronald M; Paquerault, Sophie; Lo, Joseph; Hoffmeister, Jeffrey; Armato, Samuel G; Freedman, Matthew T; Lin, Jesse; Lo, Shih-Chung Ben; Petrick, Nicholas; Sahiner, Berkman; Fryd, David; Yoshida, Hiroyuki; Chan, Heang-Ping

    2013-07-01

    Computer-aided detection/diagnosis (CAD) is increasingly used for decision support by clinicians for detection and interpretation of diseases. However, there are no quality assurance (QA) requirements for CAD in clinical use at present. QA of CAD is important so that end users can be made aware of changes in CAD performance both due to intentional or unintentional causes. In addition, end-user training is critical to prevent improper use of CAD, which could potentially result in lower overall clinical performance. Research on QA of CAD and user training are limited to date. The purpose of this paper is to bring attention to these issues, inform the readers of the opinions of the members of the American Association of Physicists in Medicine (AAPM) CAD subcommittee, and thus stimulate further discussion in the CAD community on these topics. The recommendations in this paper are intended to be work items for AAPM task groups that will be formed to address QA and user training issues on CAD in the future. The work items may serve as a framework for the discussion and eventual design of detailed QA and training procedures for physicists and users of CAD. Some of the recommendations are considered by the subcommittee to be reasonably easy and practical and can be implemented immediately by the end users; others are considered to be "best practice" approaches, which may require significant effort, additional tools, and proper training to implement. The eventual standardization of the requirements of QA procedures for CAD will have to be determined through consensus from members of the CAD community, and user training may require support of professional societies. It is expected that high-quality CAD and proper use of CAD could allow these systems to achieve their true potential, thus benefiting both the patients and the clinicians, and may bring about more widespread clinical use of CAD for many other diseases and applications. It is hoped that the awareness of the need

  3. NEXUS/NASCAD- NASA ENGINEERING EXTENDIBLE UNIFIED SOFTWARE SYSTEM WITH NASA COMPUTER AIDED DESIGN

    NASA Technical Reports Server (NTRS)

    Purves, L. R.

    1994-01-01

    NEXUS, the NASA Engineering Extendible Unified Software system, is a research set of computer programs designed to support the full sequence of activities encountered in NASA engineering projects. This sequence spans preliminary design, design analysis, detailed design, manufacturing, assembly, and testing. NEXUS primarily addresses the process of prototype engineering, the task of getting a single or small number of copies of a product to work. Prototype engineering is a critical element of large scale industrial production. The time and cost needed to introduce a new product are heavily dependent on two factors: 1) how efficiently required product prototypes can be developed, and 2) how efficiently required production facilities, also a prototype engineering development, can be completed. NEXUS extendibility and unification are achieved by organizing the system as an arbitrarily large set of computer programs accessed in a common manner through a standard user interface. The NEXUS interface is a multipurpose interactive graphics interface called NASCAD (NASA Computer Aided Design). NASCAD can be used to build and display two and three-dimensional geometries, to annotate models with dimension lines, text strings, etc., and to store and retrieve design related information such as names, masses, and power requirements of components used in the design. From the user's standpoint, NASCAD allows the construction, viewing, modification, and other processing of data structures that represent the design. Four basic types of data structures are supported by NASCAD: 1) three-dimensional geometric models of the object being designed, 2) alphanumeric arrays to hold data ranging from numeric scalars to multidimensional arrays of numbers or characters, 3) tabular data sets that provide a relational data base capability, and 4) procedure definitions to combine groups of system commands or other user procedures to create more powerful functions. NASCAD has extensive abilities to

  4. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  5. A hybrid fuzzy-neural system for computer-aided diagnosis of ultrasound kidney images using prominent features.

    PubMed

    Bommanna Raja, K; Madheswaran, M; Thyagarajah, K

    2008-02-01

    The objective of this work is to develop and implement a computer-aided decision support system for an automated diagnosis and classification of ultrasound kidney images. The proposed method distinguishes three kidney categories namely normal, medical renal diseases and cortical cyst. For the each pre-processed ultrasound kidney image, 36 features are extracted. Two types of decision support systems, optimized multi-layer back propagation network and hybrid fuzzy-neural system have been developed with these features for classifying the kidney categories. The performance of the hybrid fuzzy-neural system is compared with the optimized multi-layer back propagation network in terms of classification efficiency, training and testing time. The results obtained show that fuzzy-neural system provides higher classification efficiency with minimum training and testing time. It has also been found that instead of using all 36 features, ranking the features enhance classification efficiency. The outputs of the decision support systems are validated with medical expert to measure the actual efficiency. The overall discriminating capability of the systems is accessed with performance evaluation measure, f-score. It has been observed that the performance of fuzzy-neural system is superior compared to optimized multi-layer back propagation network. Such hybrid fuzzy-neural system with feature extraction algorithms and pre-processing scheme helps in developing computer-aided diagnosis system for ultrasound kidney images and can be used as a secondary observer in clinical decision making.

  6. A Short Review of Chemical Reaction Database Systems, Computer-Aided Synthesis Design, Reaction Prediction and Synthetic Feasibility.

    PubMed

    Warr, Wendy A

    2014-06-01

    This article is the text for a pedagogical lecture to be given at the Strasbourg Summer School in Chemoinformatics in June 2104. It covers a very wide range of reaction topics including structure and reaction representation, reaction centers, atom-to-atom mapping, reaction retrieval systems, computer-aided synthesis design, retrosynthesis, reaction prediction and synthetic feasibility. In the time available the coverage of each topic can only be cursory; the main usefulness of this article to the research community is the extensive bibliography.

  7. NEXUS/NASCAD- NASA ENGINEERING EXTENDIBLE UNIFIED SOFTWARE SYSTEM WITH NASA COMPUTER AIDED DESIGN

    NASA Technical Reports Server (NTRS)

    Purves, L. R.

    1994-01-01

    NEXUS, the NASA Engineering Extendible Unified Software system, is a research set of computer programs designed to support the full sequence of activities encountered in NASA engineering projects. This sequence spans preliminary design, design analysis, detailed design, manufacturing, assembly, and testing. NEXUS primarily addresses the process of prototype engineering, the task of getting a single or small number of copies of a product to work. Prototype engineering is a critical element of large scale industrial production. The time and cost needed to introduce a new product are heavily dependent on two factors: 1) how efficiently required product prototypes can be developed, and 2) how efficiently required production facilities, also a prototype engineering development, can be completed. NEXUS extendibility and unification are achieved by organizing the system as an arbitrarily large set of computer programs accessed in a common manner through a standard user interface. The NEXUS interface is a multipurpose interactive graphics interface called NASCAD (NASA Computer Aided Design). NASCAD can be used to build and display two and three-dimensional geometries, to annotate models with dimension lines, text strings, etc., and to store and retrieve design related information such as names, masses, and power requirements of components used in the design. From the user's standpoint, NASCAD allows the construction, viewing, modification, and other processing of data structures that represent the design. Four basic types of data structures are supported by NASCAD: 1) three-dimensional geometric models of the object being designed, 2) alphanumeric arrays to hold data ranging from numeric scalars to multidimensional arrays of numbers or characters, 3) tabular data sets that provide a relational data base capability, and 4) procedure definitions to combine groups of system commands or other user procedures to create more powerful functions. NASCAD has extensive abilities to

  8. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  9. Computer-Aided Reliability Estimation

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.

    1986-01-01

    CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.

  10. Robust computer-aided synthesis and optimization of linear multivariable control systems with varying plant dynamics via AUTOCON

    NASA Technical Reports Server (NTRS)

    Lefkowitz, C. P.; Tekawy, J. A.; Pujara, P. K.; Safonov, M. G.

    1989-01-01

    AUTOCON is an automated computer-aided design tool for the synthesis and optimization of linear multivariable control systems based upon user-defined control parameter optimization. Violations in stability and performance requirements are computed from constraints on Single Input/Single Output (SISO) open- and closed-loop transfer function frequency responses, and from constraints on the singular-value frequency responses of Multiple Input/Multiple Output (MIMO) transfer functions, for all critical plant variations. Optimum nonlinear programming algorithms are used in the search for local constrained solutions in which violations in stability and performance are caused either to vanish or be minimized for a proper selection of the control parameters. Classical control system stability and performance design can, in this way, be combined with modern multivariable robustness methods to offer general frequency response loop-shaping via a computer-aided design tool. Complete Nichols, Nyquist, Bode, singular-value Bode magnitude and transient response plots are produced, including user-defined boundary responses. AUTOCON is used to synthesize and optimize the lateral/directional flight control system for a typical high-performance aircraft.

  11. Ischemic Stroke Detection System with a Computer-Aided Diagnostic Ability Using an Unsupervised Feature Perception Enhancement Method

    PubMed Central

    Tyan, Yeu-Sheng; Wu, Ming-Chi; Chin, Chiun-Li; Kuo, Yu-Liang; Lee, Ming-Sian; Chang, Hao-Yan

    2014-01-01

    We propose an ischemic stroke detection system with a computer-aided diagnostic ability using a four-step unsupervised feature perception enhancement method. In the first step, known as preprocessing, we use a cubic curve contrast enhancement method to enhance image contrast. In the second step, we use a series of methods to extract the brain tissue image area identified during preprocessing. To detect abnormal regions in the brain images, we propose using an unsupervised region growing algorithm to segment the brain tissue area. The brain is centered on a horizontal line and the white matter of the brain's inner ring is split into eight regions. In the third step, we use a coinciding regional location method to find the hybrid area of locations where a stroke may have occurred in each cerebral hemisphere. Finally, we make corrections and mark the stroke area with red color. In the experiment, we tested the system on 90 computed tomography (CT) images from 26 patients, and, with the assistance of two radiologists, we proved that our proposed system has computer-aided diagnostic capabilities. Our results show an increased stroke diagnosis sensitivity of 83% in comparison to 31% when radiologists use conventional diagnostic images. PMID:25610453

  12. Ischemic stroke detection system with a computer-aided diagnostic ability using an unsupervised feature perception enhancement method.

    PubMed

    Tyan, Yeu-Sheng; Wu, Ming-Chi; Chin, Chiun-Li; Kuo, Yu-Liang; Lee, Ming-Sian; Chang, Hao-Yan

    2014-01-01

    We propose an ischemic stroke detection system with a computer-aided diagnostic ability using a four-step unsupervised feature perception enhancement method. In the first step, known as preprocessing, we use a cubic curve contrast enhancement method to enhance image contrast. In the second step, we use a series of methods to extract the brain tissue image area identified during preprocessing. To detect abnormal regions in the brain images, we propose using an unsupervised region growing algorithm to segment the brain tissue area. The brain is centered on a horizontal line and the white matter of the brain's inner ring is split into eight regions. In the third step, we use a coinciding regional location method to find the hybrid area of locations where a stroke may have occurred in each cerebral hemisphere. Finally, we make corrections and mark the stroke area with red color. In the experiment, we tested the system on 90 computed tomography (CT) images from 26 patients, and, with the assistance of two radiologists, we proved that our proposed system has computer-aided diagnostic capabilities. Our results show an increased stroke diagnosis sensitivity of 83% in comparison to 31% when radiologists use conventional diagnostic images.

  13. Computer Aided Drafting. Instructor's Guide.

    ERIC Educational Resources Information Center

    Henry, Michael A.

    This guide is intended for use in introducing students to the operation and applications of computer-aided drafting (CAD) systems. The following topics are covered in the individual lessons: understanding CAD (CAD versus traditional manual drafting and care of software and hardware); using the components of a CAD system (primary and other input…

  14. Towards a computer-aided diagnosis system for colon motility dysfunctions

    NASA Astrophysics Data System (ADS)

    Glocker, Ben; Buhmann, Sonja; Kirchhoff, Chlodwig; Mussack, Thomas; Reiser, Maximilian; Navab, Nassir

    2007-03-01

    Colon motility disorders are a very common problem. A precise diagnosis with current methods is almost unachievable. This makes it extremely difficult for the clinical experts to decide for the right intervention such as colon resection. The use of cine MRI for visualizing the colon motility is a very promising technique. In addition, if image segmentation and qualitative motion analysis provide the necessary tools, it could provide the appropriate diagnostic solution. In this work we defined necessary steps in the image processing workflow to gain valuable measurements for a computer aided diagnosis of colon motility disorders. For each step, we developed methods to deal with the dynamic image data. There is need for compensating the breathing motion since no respiratory gating could be used. We segment the colon using a graph cuts approach in 2D and 3D for further analysis and visualization. The analysis of the large bowel motility is done by tracking the extension of the colon during a propagating peristaltic wave. The main objective of this work is to extract a motion model to define a clinical index that can be used in diagnosis of large bowel motility dysfunction. We aim at the classification and localization of such pathologies.

  15. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of...

  16. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of...

  17. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of...

  18. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of...

  19. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of...

  20. Computer aided engineering analysis of automotive bumpers

    SciTech Connect

    Glance, P.M.

    1984-01-01

    This paper presents a description of a general purpose, computer-aided engineering design methodology which has been employed in the design of automotive bumper systems. A comparison of computer-aided analysis predictions with actual test data is presented. Two case histories of bumper system designs are discussed.

  1. Computer Aided Design in Engineering Education.

    ERIC Educational Resources Information Center

    Gobin, R.

    1986-01-01

    Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)

  2. Issues in Expanding the Software Base Management System Supporting the Computer Aided Prototyping System

    DTIC Science & Technology

    1990-06-01

    and deficient in their stated requirements. The problem involves not only the high cost of software development, but also in the poor quality of...to improving software development productivity and quality [Ref. 4]. It also has the most potential in the short term to show tangible benefits in a...real-time embedded systems [Ref. 5]. This system differs in its approach from most other prototyping systems in its approach to software generation from

  3. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    NASA Astrophysics Data System (ADS)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  4. A web-based computer aided system for liver surgery planning: initial implementation on RayPlus

    NASA Astrophysics Data System (ADS)

    Luo, Ming; Yuan, Rong; Sun, Zhi; Li, Tianhong; Xie, Qingguo

    2016-03-01

    At present, computer aided systems for liver surgery design and risk evaluation are widely used in clinical all over the world. However, most systems are local applications that run on high-performance workstations, and the images have to processed offline. Compared with local applications, a web-based system is accessible anywhere and for a range of regardless of relative processing power or operating system. RayPlus (http://rayplus.life.hust.edu.cn), a B/S platform for medical image processing, was developed to give a jump start on web-based medical image processing. In this paper, we implement a computer aided system for liver surgery planning on the architecture of RayPlus. The system consists of a series of processing to CT images including filtering, segmentation, visualization and analyzing. Each processing is packaged into an executable program and runs on the server side. CT images in DICOM format are processed step by to interactive modeling on browser with zero-installation and server-side computing. The system supports users to semi-automatically segment the liver, intrahepatic vessel and tumor from the pre-processed images. Then, surface and volume models are built to analyze the vessel structure and the relative position between adjacent organs. The results show that the initial implementation meets satisfactorily its first-order objectives and provide an accurate 3D delineation of the liver anatomy. Vessel labeling and resection simulation are planned to add in the future. The system is available on Internet at the link mentioned above and an open username for testing is offered.

  5. Intelligent computer aided training systems in the real world: Making the technology accessible to the educational mainstream

    NASA Technical Reports Server (NTRS)

    Kovarik, Madeline

    1993-01-01

    Intelligent computer aided training systems hold great promise for the application of this technology to mainstream education and training. Yet, this technology, which holds such a vast potential impact for the future of education and training, has had little impact beyond the enclaves of government research labs. This is largely due to the inaccessibility of the technology to those individuals in whose hands it can have the greatest impact, teachers and educators. Simply throwing technology at an educator and expecting them to use it as an effective tool is not the answer. This paper provides a background into the use of technology as a training tool. MindLink, developed by HyperTech Systems, provides trainers with a powerful rule-based tool that can be integrated directly into a Windows application. By embedding expert systems technology it becomes more accessible and easier to master.

  6. Transmission dispatch and congestion management in open market systems

    NASA Astrophysics Data System (ADS)

    Fang, Risheng

    This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally

  7. Computer aided reliability, availability, and safety modeling for fault-tolerant computer systems with commentary on the HARP program

    NASA Technical Reports Server (NTRS)

    Shooman, Martin L.

    1991-01-01

    Many of the most challenging reliability problems of our present decade involve complex distributed systems such as interconnected telephone switching computers, air traffic control centers, aircraft and space vehicles, and local area and wide area computer networks. In addition to the challenge of complexity, modern fault-tolerant computer systems require very high levels of reliability, e.g., avionic computers with MTTF goals of one billion hours. Most analysts find that it is too difficult to model such complex systems without computer aided design programs. In response to this need, NASA has developed a suite of computer aided reliability modeling programs beginning with CARE 3 and including a group of new programs such as: HARP, HARP-PC, Reliability Analysts Workbench (Combination of model solvers SURE, STEM, PAWS, and common front-end model ASSIST), and the Fault Tree Compiler. The HARP program is studied and how well the user can model systems using this program is investigated. One of the important objectives will be to study how user friendly this program is, e.g., how easy it is to model the system, provide the input information, and interpret the results. The experiences of the author and his graduate students who used HARP in two graduate courses are described. Some brief comparisons were made with the ARIES program which the students also used. Theoretical studies of the modeling techniques used in HARP are also included. Of course no answer can be any more accurate than the fidelity of the model, thus an Appendix is included which discusses modeling accuracy. A broad viewpoint is taken and all problems which occurred in the use of HARP are discussed. Such problems include: computer system problems, installation manual problems, user manual problems, program inconsistencies, program limitations, confusing notation, long run times, accuracy problems, etc.

  8. Image-based retrieval system and computer-aided diagnosis system for renal cortical scintigraphy images

    NASA Astrophysics Data System (ADS)

    Mumcuoğlu, Erkan; Nar, Fatih; Uğur, Omer; Bozkurt, M. Fani; Aslan, Mehmet

    2008-03-01

    Cortical renal (kidney) scintigraphy images are 2D images (256x256) acquired in three projection angles (posterior, right-posterior-oblique and left-posterior-oblique). These images are used by nuclear medicine specialists to examine the functional morphology of kidney parenchyma. The main visual features examined in reading the images are: size, location, shape and activity distribution (pixel intensity distribution within the boundary of each kidney). Among the above features, activity distribution (in finding scars if any) was found to have the least interobserver reproducibility. Therefore, in this study, we developed an image-based retrieval (IBR) and a computer-based diagnosis (CAD) system, focused on this feature in particular. The developed IBR and CAD algorithms start with automatic segmentation, boundary and landmark detection. Then, shape and activity distribution features are computed. Activity distribution feature is obtained using the acquired image and image set statistics of the normal patients. Active Shape Model (ASM) technique is used for more accurate kidney segmentation. In the training step of ASM, normal patient images are used. Retrieval performance is evaluated by calculating precision and recall. CAD performance is evaluated by specificity and sensitivity. To our knowledge, this paper is the first IBR or CAD system reported in the literature on renal cortical scintigraphy images.

  9. Evaluation of a stand-alone computer-aided detection system for acute intra-cranial hemorrhage in emergency environments

    NASA Astrophysics Data System (ADS)

    Fernandez, James; Deshpande, Ruchi; Wang, Ximing; Liu, Brent; Brazaitis, Michael; Munter, Fletcher; Liu, Margaret

    2011-03-01

    Acute intra-cranial hemorrhage (AIH) may result from traumatic brain injury (TBI). Successful management of AIH depends heavily on the speed and accuracy of diagnosis. Timely diagnosis in emergency environments in both civilian and military settings is difficult primarily due to severe time restraints and lack of resources. Often, diagnosis is performed by emergency physicians rather than trained radiologists. As a result, added support in the form of computer-aided detection (CAD) would greatly enhance the decision-making process and help in providing faster and more accurate diagnosis of AIH. This paper discusses the implementation of a CAD system in an emergency environment, and its efficacy in aiding in the detection of AIH.

  10. Dispatch Strategy Development for Grid-tied Household Energy Systems

    NASA Astrophysics Data System (ADS)

    Cardwell, Joseph

    The prevalence of renewable generation will increase in the next several decades and offset conventional generation more and more. Yet this increase is not coming without challenges. Solar, wind, and even some water resources are intermittent and unpredictable, and thereby create scheduling challenges due to their inherent "uncontrolled" nature. To effectively manage these distributed renewable assets, new control algorithms must be developed for applications including energy management, bridge power, and system stability. This can be completed through a centralized control center though efforts are being made to parallel the control architecture with the organization of the renewable assets themselves--namely, distributed controls. Building energy management systems are being employed to control localized energy generation, storage, and use to reduce disruption on the net utility load. One such example is VOLTTRONTM, an agent-based platform for building energy control in real time. In this thesis, algorithms developed in VOLTTRON simulate a home energy management system that consists of a solar PV array, a lithium-ion battery bank, and the grid. Dispatch strategies are implemented to reduce energy charges from overall consumption (/kWh) and demand charges (/kW). Dispatch strategies for implementing storage devices are tuned on a month-to-month basis to provide a meaningful economic advantage under simulated scenarios to explore algorithm sensitivity to changing external factors. VOLTTRON agents provide automated real-time optimization of dispatch strategies to efficiently manage energy supply and demand, lower consumer costs associated with energy usage, and reduce load on the utility grid.

  11. Computer Aided Manufacturing.

    ERIC Educational Resources Information Center

    Insolia, Gerard

    This document contains course outlines in computer-aided manufacturing developed for a business-industry technology resource center for firms in eastern Pennsylvania by Northampton Community College. The four units of the course cover the following: (1) introduction to computer-assisted design (CAD)/computer-assisted manufacturing (CAM); (2) CAM…

  12. Computer Aided Art Major.

    ERIC Educational Resources Information Center

    Gibson, Jim

    The Computer Aided Art program offered at Northern State State University (Aberdeen, South Dakota), is coordinated with the traditional art major. The program is designed to familiarize students with a wide range of art-related computer hardware and software and their applications and to prepare students for problem-solving with unfamiliar…

  13. Incorporating texture features in a computer-aided breast lesion diagnosis system for automated three-dimensional breast ultrasound.

    PubMed

    Liu, Haixia; Tan, Tao; van Zelst, Jan; Mann, Ritse; Karssemeijer, Nico; Platel, Bram

    2014-07-01

    We investigated the benefits of incorporating texture features into an existing computer-aided diagnosis (CAD) system for classifying benign and malignant lesions in automated three-dimensional breast ultrasound images. The existing system takes into account 11 different features, describing different lesion properties; however, it does not include texture features. In this work, we expand the system by including texture features based on local binary patterns, gray level co-occurrence matrices, and Gabor filters computed from each lesion to be diagnosed. To deal with the resulting large number of features, we proposed a combination of feature-oriented classifiers combining each group of texture features into a single likelihood, resulting in three additional features used for the final classification. The classification was performed using support vector machine classifiers, and the evaluation was done with 10-fold cross validation on a dataset containing 424 lesions (239 benign and 185 malignant lesions). We compared the classification performance of the CAD system with and without texture features. The area under the receiver operating characteristic curve increased from 0.90 to 0.91 after adding texture features ([Formula: see text]).

  14. Incorporating texture features in a computer-aided breast lesion diagnosis system for automated three-dimensional breast ultrasound

    PubMed Central

    Liu, Haixia; Tan, Tao; van Zelst, Jan; Mann, Ritse; Karssemeijer, Nico; Platel, Bram

    2014-01-01

    Abstract. We investigated the benefits of incorporating texture features into an existing computer-aided diagnosis (CAD) system for classifying benign and malignant lesions in automated three-dimensional breast ultrasound images. The existing system takes into account 11 different features, describing different lesion properties; however, it does not include texture features. In this work, we expand the system by including texture features based on local binary patterns, gray level co-occurrence matrices, and Gabor filters computed from each lesion to be diagnosed. To deal with the resulting large number of features, we proposed a combination of feature-oriented classifiers combining each group of texture features into a single likelihood, resulting in three additional features used for the final classification. The classification was performed using support vector machine classifiers, and the evaluation was done with 10-fold cross validation on a dataset containing 424 lesions (239 benign and 185 malignant lesions). We compared the classification performance of the CAD system with and without texture features. The area under the receiver operating characteristic curve increased from 0.90 to 0.91 after adding texture features (p<0.001). PMID:26158036

  15. Building a computer-aided design capability using a standard time share operating system

    NASA Technical Reports Server (NTRS)

    Sobieszczanski, J.

    1975-01-01

    The paper describes how an integrated system of engineering computer programs can be built using a standard commercially available operating system. The discussion opens with an outline of the auxiliary functions that an operating system can perform for a team of engineers involved in a large and complex task. An example of a specific integrated system is provided to explain how the standard operating system features can be used to organize the programs into a simple and inexpensive but effective system. Applications to an aircraft structural design study are discussed to illustrate the use of an integrated system as a flexible and efficient engineering tool. The discussion concludes with an engineer's assessment of an operating system's capabilities and desirable improvements.

  16. Design Considerations in Development of Minicomputer-Based Computer Aided Instructional Hardware Systems.

    ERIC Educational Resources Information Center

    Wells, C. H.

    A minicomputer-based computer-assisted instructional (CAI) system was designed at the University of Texas Medical Branch in an attempt to lower both the excessive hardware costs and the inordinate amount of time required for the preparation of each hour of instructional material associated with traditional CAI systems. A prototype system with an…

  17. Computer-Aided Decisions in Human Services: Expert Systems and Multivariate Models.

    ERIC Educational Resources Information Center

    Sicoly, Fiore

    1989-01-01

    This comparison of two approaches to the development of computerized supports for decision making--expert systems and multivariate models--focuses on computerized systems that assist professionals with tasks related to diagnosis or classification in human services. Validation of both expert systems and statistical models is emphasized. (39…

  18. Development and Evaluation of Computer-Aided Music-Learning System for the Hearing Impaired

    ERIC Educational Resources Information Center

    Yang, H.-J.; Lay, Y.-L.; Liou, Y.-C.; Tsao, W.-Y.; Lin, C.-K.

    2007-01-01

    A computer-assisted music-learning system (CAMLS) has been developed to help the hearing impaired practice playing a musical melody. The music-learning performance is evaluated to test the usability of the system. This system can be a computer-supported learning tool for the hearing impaired to help them understand what pitch and tempo are, and…

  19. Independent Component Analysis-Support Vector Machine-Based Computer-Aided Diagnosis System for Alzheimer's with Visual Support.

    PubMed

    Khedher, Laila; Illán, Ignacio A; Górriz, Juan M; Ramírez, Javier; Brahim, Abdelbasset; Meyer-Baese, Anke

    2017-05-01

    Computer-aided diagnosis (CAD) systems constitute a powerful tool for early diagnosis of Alzheimer's disease (AD), but limitations on interpretability and performance exist. In this work, a fully automatic CAD system based on supervised learning methods is proposed to be applied on segmented brain magnetic resonance imaging (MRI) from Alzheimer's disease neuroimaging initiative (ADNI) participants for automatic classification. The proposed CAD system possesses two relevant characteristics: optimal performance and visual support for decision making. The CAD is built in two stages: a first feature extraction based on independent component analysis (ICA) on class mean images and, secondly, a support vector machine (SVM) training and classification. The obtained features for classification offer a full graphical representation of the images, giving an understandable logic in the CAD output, that can increase confidence in the CAD support. The proposed method yields classification results up to 89% of accuracy (with 92% of sensitivity and 86% of specificity) for normal controls (NC) and AD patients, 79% of accuracy (with 82% of sensitivity and 76% of specificity) for NC and mild cognitive impairment (MCI), and 85% of accuracy (with 85% of sensitivity and 86% of specificity) for MCI and AD patients.

  20. Development of the engineering design integration (EDIN) system: A computer aided design development

    NASA Technical Reports Server (NTRS)

    Glatt, C. R.; Hirsch, G. N.

    1977-01-01

    The EDIN (Engineering Design Integration) System which provides a collection of hardware and software, enabling the engineer to perform man-in-the-loop interactive evaluation of aerospace vehicle concepts, was considered. Study efforts were concentrated in the following areas: (1) integration of hardware with the Univac Exec 8 System; (2) development of interactive software for the EDIN System; (3) upgrading of the EDIN technology module library to an interactive status; (4) verification of the soundness of the developing EDIN System; (5) support of NASA in design analysis studies using the EDIN System; (6) provide training and documentation in the use of the EDIN System; and (7) provide an implementation plan for the next phase of development and recommendations for meeting long range objectives.

  1. Computer-aided cluster expansion: An efficient algebraic approach for open quantum many-particle systems

    NASA Astrophysics Data System (ADS)

    Foerster, A.; Leymann, H. A. M.; Wiersig, J.

    2017-03-01

    We introduce an equation of motion approach that allows for an approximate evaluation of the time evolution of a quantum system, where the algebraic work to derive the equations of motion is done by the computer. The introduced procedures offer a variety of different types of approximations applicable for finite systems with strong coupling as well as for arbitrary large systems where augmented mean-field theories like the cluster expansion can be applied.

  2. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, Earl A.; Lipshutz, Robert J.; Morris, Macdonald S.; Winkler, James L.

    1997-01-01

    An improved set of computer tools for forming arrays. According to one aspect of the invention, a computer system is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files to design and/or generate lithographic masks.

  3. [Development of a computer-aided system for augmentation mammaplasty simulation].

    PubMed

    Li, Xiao-Jian; Jun, Feng; Gao, Jian-Hu; Li, Shi-Heng; Cao, Lei

    2007-10-01

    A method for developing a three-dimensional visual system for simulating augmentation mammaplasty based on OpenGL is proposed. The 3D reconstruction of breast surface using NURBS, reality simulation of the breast surface, parametric design of mammary prosthesis, and simulation of postoperative effect are described. The system may provide a means for better communication between the surgeons and patients.

  4. Computer-aided operations engineering with integrated models of systems and operations

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.; Ryan, Dan; Fleming, Land

    1994-01-01

    CONFIG 3 is a prototype software tool that supports integrated conceptual design evaluation from early in the product life cycle, by supporting isolated or integrated modeling, simulation, and analysis of the function, structure, behavior, failures and operation of system designs. Integration and reuse of models is supported in an object-oriented environment providing capabilities for graph analysis and discrete event simulation. Integration is supported among diverse modeling approaches (component view, configuration or flow path view, and procedure view) and diverse simulation and analysis approaches. Support is provided for integrated engineering in diverse design domains, including mechanical and electro-mechanical systems, distributed computer systems, and chemical processing and transport systems. CONFIG supports abstracted qualitative and symbolic modeling, for early conceptual design. System models are component structure models with operating modes, with embedded time-related behavior models. CONFIG supports failure modeling and modeling of state or configuration changes that result in dynamic changes in dependencies among components. Operations and procedure models are activity structure models that interact with system models. CONFIG is designed to support evaluation of system operability, diagnosability and fault tolerance, and analysis of the development of system effects of problems over time, including faults, failures, and procedural or environmental difficulties.

  5. Development of a computer-aided detection system for lung cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Suzuki, Hideo; Inaoka, Noriko; Takabatake, Hirotsugu; Mori, Masaki; Sasaoka, Soichi; Natori, Hiroshi; Suzuki, Akira

    1992-06-01

    This paper describes a modified system for automatic detection of lung nodules by means of chest x ray image processing techniques. The objective of the system is to help radiologists to improve their accuracy in cancer detection. It is known from retrospective studies of chest x- ray images that radiologists fail to detect about 30 percent of lung cancer cases. A computerized method for detecting lung nodules would be very useful for decreasing the proportion of such oversights. Our proposed system consists of five sub-systems, for image input, lung region determination, nodule detection, rule-based false-positive elimination, and statistical false-positive elimination. In an experiment with the modified system, using 30 lung cancer cases and 78 normal control cases, we obtained figures of 73.3 percent and 89.7 percent for the sensitivity and specificity of the system, respectively. The system has been developed to run on the IBM* PS/55* and IBM RISC System/6000* (RS/6000), and we give the processing time for each platform.

  6. The development of computer-aided system for tissue scaffolds (CASTS) system for functionally graded tissue-engineering scaffolds.

    PubMed

    Sudarmadji, Novella; Chua, Chee Kai; Leong, Kah Fai

    2012-01-01

    Computer-aided system for tissue scaffolds (CASTS) is an in-house parametric library of polyhedral units that can be assembled into customized tissue scaffolds. Thirteen polyhedral configurations are available to select, depending on the biological and mechanical requirements of the target tissue/organ. Input parameters include the individual polyhedral units and overall scaffold block as well as the scaffold strut diameter. Taking advantage of its repeatability and reproducibility, the scaffold file is then converted into .STL file and fabricated using selective laser sintering, a rapid prototyping system. CASTS seeks to fulfill anatomical, biological, and mechanical requirements of the target tissue/organ. Customized anatomical scaffold shape is achieved through a Boolean operation between the scaffold block and the tissue defect image. Biological requirements, such as scaffold pore size and porosity, are unique for different type of cells. Matching mechanical properties, such as stiffness and strength, between the scaffold and target organ is very important, particularly in the regeneration of load-bearing organ, i.e., bone. This includes mimicking the compressive stiffness variation across the bone to prevent stress shielding and ensuring that the scaffold can withstand the load normally borne by the bone. The stiffness variation is tailored by adjusting the scaffold porosity based on the porosity-stiffness relationship of the CASTS scaffolds. Two types of functional gradients based on the gradient direction include radial and axial/linear gradient. Radial gradient is useful in the case of regenerating a section of long bones while the gradient in linear direction can be used in short or irregular bones. Stiffness gradient in the radial direction is achieved by using cylindrical unit cells arranged in a concentric manner, in which the porosity decreases from the center of the structure toward the outside radius, making the scaffold stiffer at the outer radius

  7. CASE/A - COMPUTER AIDED SYSTEM ENGINEERING AND ANALYSIS, ECLSS/ATCS SERIES

    NASA Technical Reports Server (NTRS)

    Bacskay, A.

    1994-01-01

    Design and analysis of Environmental Control and Life Support Systems (ECLSS) and Active Thermal Control Systems (ATCS) for spacecraft missions requires powerful software that is flexible and responsive to the demands of particular projects. CASE/A is an interactive trade study and analysis tool designed to increase productivity during all phases of systems engineering. The graphics-based command-driven package provides a user-friendly environment in which the engineer can analyze the performance and interface characteristics of an ECLS/ATC system. The package is useful during all phases of a spacecraft design program, from initial conceptual design trade studies to the actual flight, including pre-flight prediction and in-flight anomaly analysis. The CASE/A program consists of three fundamental parts: 1) the schematic management system, 2) the database management system, and 3) the simulation control and execution system. The schematic management system allows the user to graphically construct a system model by arranging icons representing system components and connecting the components with physical fluid streams. Version 4.1 contains 51 fully coded and documented default component routines. New components can be added by the user through the "blackbox" component option. The database management system supports the storage and manipulation of component data, output data, and solution control data through interactive edit screens. The simulation control and execution system initiates and controls the iterative solution process, displaying time status and any necessary diagnostic messages. In addition to these primary functions, the program provides three other important functional areas: 1) model output management, 2) system utility commands, and 3) user operations logic capacity. The model output management system provides tabular and graphical output capability. Complete fluid constituent mass fraction and properties data (mass flow, pressure, temperature

  8. CASE/A - COMPUTER AIDED SYSTEM ENGINEERING AND ANALYSIS, ECLSS/ATCS SERIES

    NASA Technical Reports Server (NTRS)

    Bacskay, A.

    1994-01-01

    Design and analysis of Environmental Control and Life Support Systems (ECLSS) and Active Thermal Control Systems (ATCS) for spacecraft missions requires powerful software that is flexible and responsive to the demands of particular projects. CASE/A is an interactive trade study and analysis tool designed to increase productivity during all phases of systems engineering. The graphics-based command-driven package provides a user-friendly environment in which the engineer can analyze the performance and interface characteristics of an ECLS/ATC system. The package is useful during all phases of a spacecraft design program, from initial conceptual design trade studies to the actual flight, including pre-flight prediction and in-flight anomaly analysis. The CASE/A program consists of three fundamental parts: 1) the schematic management system, 2) the database management system, and 3) the simulation control and execution system. The schematic management system allows the user to graphically construct a system model by arranging icons representing system components and connecting the components with physical fluid streams. Version 4.1 contains 51 fully coded and documented default component routines. New components can be added by the user through the "blackbox" component option. The database management system supports the storage and manipulation of component data, output data, and solution control data through interactive edit screens. The simulation control and execution system initiates and controls the iterative solution process, displaying time status and any necessary diagnostic messages. In addition to these primary functions, the program provides three other important functional areas: 1) model output management, 2) system utility commands, and 3) user operations logic capacity. The model output management system provides tabular and graphical output capability. Complete fluid constituent mass fraction and properties data (mass flow, pressure, temperature

  9. Operator Station Design System - A computer aided design approach to work station layout

    NASA Technical Reports Server (NTRS)

    Lewis, J. L.

    1979-01-01

    The Operator Station Design System is resident in NASA's Johnson Space Center Spacecraft Design Division Performance Laboratory. It includes stand-alone minicomputer hardware and Panel Layout Automated Interactive Design and Crew Station Assessment of Reach software. The data base consists of the Shuttle Transportation System Orbiter Crew Compartment (in part), the Orbiter payload bay and remote manipulator (in part), and various anthropometric populations. The system is utilized to provide panel layouts, assess reach and vision, determine interference and fit problems early in the design phase, study design applications as a function of anthropometric and mission requirements, and to accomplish conceptual design to support advanced study efforts.

  10. Computer-aided multiple-head 3D printing system for printing of heterogeneous organ/tissue constructs

    PubMed Central

    Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo

    2016-01-01

    Recently, much attention has focused on replacement or/and enhancement of biological tissues via the use of cell-laden hydrogel scaffolds with an architecture that mimics the tissue matrix, and with the desired three-dimensional (3D) external geometry. However, mimicking the heterogeneous tissues that most organs and tissues are formed of is challenging. Although multiple-head 3D printing systems have been proposed for fabricating heterogeneous cell-laden hydrogel scaffolds, to date only the simple exterior form has been realized. Here we describe a computer-aided design and manufacturing (CAD/CAM) system for this application. We aim to develop an algorithm to enable easy, intuitive design and fabrication of a heterogeneous cell-laden hydrogel scaffolds with a free-form 3D geometry. The printing paths of the scaffold are automatically generated from the 3D CAD model, and the scaffold is then printed by dispensing four materials; i.e., a frame, two kinds of cell-laden hydrogel and a support. We demonstrated printing of heterogeneous tissue models formed of hydrogel scaffolds using this approach, including the outer ear, kidney and tooth tissue. These results indicate that this approach is particularly promising for tissue engineering and 3D printing applications to regenerate heterogeneous organs and tissues with tailored geometries to treat specific defects or injuries. PMID:26899876

  11. Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    PubMed

    Gopinath, Balasubramanian; Shanthi, Natesan

    2013-06-01

    An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foreground cell objects in cytological images using mathematical morphology and watershed transform segmentation methods. Subsequently, statistical features are extracted using two-level discrete wavelet transform (DWT) decomposition, gray level co-occurrence matrix (GLCM) and Gabor filter based methods. The classifiers k-nearest neighbor (k-NN), Elman neural network (ENN) and support vector machine (SVM) are tested for classifying benign and malignant thyroid nodules. The combination of watershed segmentation, GLCM features and k-NN classifier results a lowest diagnostic accuracy of 60 %. The highest diagnostic accuracy of 93.33 % is achieved by ENN classifier trained with the statistical features extracted by Gabor filter bank from the images segmented by morphology and watershed transform segmentation methods. It is also observed that SVM classifier results its highest diagnostic accuracy of 90 % for DWT and Gabor filter based features along with morphology and watershed transform segmentation methods. The experimental results suggest that the developed system with multi-stained thyroid FNAB images would be useful for identifying thyroid cancer irrespective of staining protocol used.

  12. A New Era for Cancer Target Therapies: Applying Systems Biology and Computer-Aided Drug Design to Cancer Therapies.

    PubMed

    Wong, Yung-Hao; Chiu, Chia-Chiun; Lin, Chih-Lung; Chen, Ting-Shou; Jheng, Bo-Ren; Lee, Yu-Ching; Chen, Jeremy; Chen, Bor-Sen

    In recent years, many systems biology approaches have been used with various cancers. The materials described here can be used to build bases to discover novel cancer therapy targets in connection with computer-aided drug design (CADD). A deeper understanding of the mechanisms of cancer will provide more choices and correct strategies in the development of multiple target drug therapies, which is quite different from the traditional cancer single target therapy. Targeted therapy is one of the most powerful strategies against cancer and can also be applied to other diseases. Due to the large amount of progress in computer hardware and the theories of computational chemistry and physics, CADD has been the main strategy for developing novel drugs for cancer therapy. In contrast to traditional single target therapies, in this review we will emphasize the future direction of the field, i.e., multiple target therapies. Structure-based and ligand-based drug designs are the two main topics of CADD. The former needs both 3D protein structures and ligand structures, while the latter only needs ligand structures. Ordinarily it is estimated to take more than 14 years and 800 million dollars to develop a new drug. Many new CADD software programs and techniques have been developed in recent decades. We conclude with an example where we combined and applied systems biology and CADD to the core networks of four cancers and successfully developed a novel cocktail for drug therapy that treats multiple targets.

  13. Computer-aided multiple-head 3D printing system for printing of heterogeneous organ/tissue constructs

    NASA Astrophysics Data System (ADS)

    Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo

    2016-02-01

    Recently, much attention has focused on replacement or/and enhancement of biological tissues via the use of cell-laden hydrogel scaffolds with an architecture that mimics the tissue matrix, and with the desired three-dimensional (3D) external geometry. However, mimicking the heterogeneous tissues that most organs and tissues are formed of is challenging. Although multiple-head 3D printing systems have been proposed for fabricating heterogeneous cell-laden hydrogel scaffolds, to date only the simple exterior form has been realized. Here we describe a computer-aided design and manufacturing (CAD/CAM) system for this application. We aim to develop an algorithm to enable easy, intuitive design and fabrication of a heterogeneous cell-laden hydrogel scaffolds with a free-form 3D geometry. The printing paths of the scaffold are automatically generated from the 3D CAD model, and the scaffold is then printed by dispensing four materials; i.e., a frame, two kinds of cell-laden hydrogel and a support. We demonstrated printing of heterogeneous tissue models formed of hydrogel scaffolds using this approach, including the outer ear, kidney and tooth tissue. These results indicate that this approach is particularly promising for tissue engineering and 3D printing applications to regenerate heterogeneous organs and tissues with tailored geometries to treat specific defects or injuries.

  14. Computer-aided multiple-head 3D printing system for printing of heterogeneous organ/tissue constructs.

    PubMed

    Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo

    2016-02-22

    Recently, much attention has focused on replacement or/and enhancement of biological tissues via the use of cell-laden hydrogel scaffolds with an architecture that mimics the tissue matrix, and with the desired three-dimensional (3D) external geometry. However, mimicking the heterogeneous tissues that most organs and tissues are formed of is challenging. Although multiple-head 3D printing systems have been proposed for fabricating heterogeneous cell-laden hydrogel scaffolds, to date only the simple exterior form has been realized. Here we describe a computer-aided design and manufacturing (CAD/CAM) system for this application. We aim to develop an algorithm to enable easy, intuitive design and fabrication of a heterogeneous cell-laden hydrogel scaffolds with a free-form 3D geometry. The printing paths of the scaffold are automatically generated from the 3D CAD model, and the scaffold is then printed by dispensing four materials; i.e., a frame, two kinds of cell-laden hydrogel and a support. We demonstrated printing of heterogeneous tissue models formed of hydrogel scaffolds using this approach, including the outer ear, kidney and tooth tissue. These results indicate that this approach is particularly promising for tissue engineering and 3D printing applications to regenerate heterogeneous organs and tissues with tailored geometries to treat specific defects or injuries.

  15. An Intelligent Computer-aided Training System (CAT) for Diagnosing Adult Illiterates: Integrating NASA Technology into Workplace Literacy

    NASA Technical Reports Server (NTRS)

    Yaden, David B., Jr.

    1991-01-01

    An important part of NASA's mission involves the secondary application of its technologies in the public and private sectors. One current application being developed is The Adult Literacy Evaluator, a simulation-based diagnostic tool designed to assess the operant literacy abilities of adults having difficulties in learning to read and write. Using Intelligent Computer-Aided Training (ICAT) system technology in addition to speech recognition, closed-captioned television (CCTV), live video and other state-of-the-art graphics and storage capabilities, this project attempts to overcome the negative effects of adult literacy assessment by allowing the client to interact with an intelligent computer system which simulates real-life literacy activities and materials and which measures literacy performance in the actual context of its use. The specific objectives of the project are as follows: (1) to develop a simulation-based diagnostic tool to assess adults' prior knowledge about reading and writing processes in actual contexts of application; (2) to provide a profile of readers' strengths and weaknesses; and (3) to suggest instructional strategies and materials which can be used as a beginning point for remediation. In the first and development phase of the project, descriptions of literacy events and environments are being written and functional literacy documents analyzed for their components. From these descriptions, scripts are being generated which define the interaction between the student, an on-screen guide and the simulated literacy environment.

  16. Feedback and its effectiveness in a computer-aided personalized system of instruction course.

    PubMed

    Martin, Toby L; Pear, Joseph J; Martin, Garry L

    2002-01-01

    In a computer-managed version of Keller's personalized system of instruction, students received frequent feedback from more advanced students within the course. Overall accuracy of student-provided feedback was 87%, and students complied with 61% of the feedback.

  17. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, Earl A.; Morris, MacDonald S.; Winkler, James L.

    1999-01-05

    An improved set of computer tools for forming arrays. According to one aspect of the invention, a computer system (100) is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files (104) to design and/or generate lithographic masks (110).

  18. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, E.A.; Morris, M.S.; Winkler, J.L.

    1996-11-05

    An improved set of computer tools for forming arrays is disclosed. According to one aspect of the invention, a computer system is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files to design and/or generate lithographic masks. 14 figs.

  19. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, Earl A.; Morris, MacDonald S.; Winkler, James L.

    1996-01-01

    An improved set of computer tools for forming arrays. According to one aspect of the invention, a computer system (100) is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files (104) to design and/or generate lithographic masks (110).

  20. Computer-Aided Mission Planning System (CAMPS) Test 1-82.

    DTIC Science & Technology

    1982-07-23

    biective6 To assess the marginal value off addin4-g Eb-erimenta. ?enetration and Analysis Support Sys-tem SPASS) tyrpe canabi !lities to the :A,,!S. .3.7...Objective To assess t-he user’s overall omnion off the .ZA.’S/:?PASS system as a mission planning tool. 1 .3.8 Objecti-,e 3 To com- oile a list off

  1. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, E.A.; Lipshutz, R.J.; Morris, M.S.; Winkler, J.L.

    1997-01-14

    An improved set of computer tools for forming arrays is disclosed. According to one aspect of the invention, a computer system is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files to design and/or generate lithographic masks. 14 figs.

  2. Computer-aided engineering system for design of sequence arrays and lithographic masks

    DOEpatents

    Hubbell, E.A.; Morris, M.S.; Winkler, J.L.

    1999-01-05

    An improved set of computer tools for forming arrays is disclosed. According to one aspect of the invention, a computer system is used to select probes and design the layout of an array of DNA or other polymers with certain beneficial characteristics. According to another aspect of the invention, a computer system uses chip design files to design and/or generate lithographic masks. 14 figs.

  3. An Intelligent computer-aided tutoring system for diagnosing anomalies of spacecraft in operation

    NASA Technical Reports Server (NTRS)

    Rolincik, Mark; Lauriente, Michael; Koons, Harry C.; Gorney, David

    1993-01-01

    A new rule-based, expert system for diagnosing spacecraft anomalies is under development. The knowledge base consists of over two-hundred (200) rules and provides links to historical and environmental databases. Environmental causes considered are bulk charging, single event upsets (SEU), surface charging, and total radiation dose. The system's driver translates forward chaining rules into a backward chaining sequence, prompting the user for information pertinent to the causes considered. When the user selects the novice mode, the system automatically gives detailed explanations and descriptions of terms and reasoning as the session progresses, in a sense teaching the user. As such it is an effective tutoring tool. The use of heuristics frees the user from searching through large amounts of irrelevant information and allows the user to input partial information (varying degrees of confidence in an answer) or 'unknown' to any question. The system is available on-line and uses C Language Integrated Production System (CLIPS), an expert shell developed by the NASA Johnson Space Center AI Laboratory in Houston.

  4. Computer-aided system for morphometric mandibular index computation (Using dental panoramic radiographs)

    PubMed Central

    Álvarez-López, Jose M.; Jané-Salas, Enrique; Estrugo-Devesa, Albert; Ayuso-Montero, Raul; Velasco-Ortega, Eugenio; Segura-Egea, Juan J.

    2012-01-01

    Objective: We propose and validate a computer—aided system to measure three different mandibular indexes: cortical width, panoramic mandibular index and, mandibular alveolar bone resorption index. Study Design: Repeatability and reproducibility of the measurements are analyzed and compared to the manual estimation of the same indexes. Results: The proposed computerized system exhibits superior repeatability and reproducibility rates compared to standard manual methods. Moreover, the time required to perform the measurements using the proposed method is negligible compared to perform the measurements manually. Conclusions: We have proposed a very user friendly computerized method to measure three different morphometric mandibular indexes. From the results we can conclude that the system provides a practical manner to perform these measurements. It does not require an expert examiner and does not take more than 16 seconds per analysis. Thus, it may be suitable to diagnose osteoporosis using dental panoramic radiographs. Key words:Osteoporosis, panoramic mandibular index, cortical width, mandibular alveolar bone resorption index. PMID:22322489

  5. Virtual environment and computer-aided technologies used for system prototyping and requirements development

    NASA Technical Reports Server (NTRS)

    Logan, Cory; Maida, James; Goldsby, Michael; Clark, Jim; Wu, Liew; Prenger, Henk

    1993-01-01

    The Space Station Freedom (SSF) Data Management System (DMS) consists of distributed hardware and software which monitor and control the many onboard systems. Virtual environment and off-the-shelf computer technologies can be used at critical points in project development to aid in objectives and requirements development. Geometric models (images) coupled with off-the-shelf hardware and software technologies were used in The Space Station Mockup and Trainer Facility (SSMTF) Crew Operational Assessment Project. Rapid prototyping is shown to be a valuable tool for operational procedure and system hardware and software requirements development. The project objectives, hardware and software technologies used, data gained, current activities, future development and training objectives shall be discussed. The importance of defining prototyping objectives and staying focused while maintaining schedules are discussed along with project pitfalls.

  6. Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS). Phase 1: Users handbook

    NASA Technical Reports Server (NTRS)

    Kim, S.; Lee, J.; Cho, B. H.; Lee, F. C.

    1986-01-01

    The EASY5 macro component models developed for the spacecraft power system simulation are described. A brief explanation about how to use the macro components with the EASY5 Standard Components to build a specific system is given through an example. The macro components are ordered according to the following functional group: converter power stage models, compensator models, current-feedback models, constant frequency control models, load models, solar array models, and shunt regulator models. Major equations, a circuit model, and a program listing are provided for each macro component.

  7. A prototype computer-aided modelling tool for life-support system models

    NASA Technical Reports Server (NTRS)

    Preisig, H. A.; Lee, Tae-Yeong; Little, Frank

    1990-01-01

    Based on the canonical decomposition of physical-chemical-biological systems, a prototype kernel has been developed to efficiently model alternative life-support systems. It supports (1) the work in an interdisciplinary group through an easy-to-use mostly graphical interface, (2) modularized object-oriented model representation, (3) reuse of models, (4) inheritance of structures from model object to model object, and (5) model data base. The kernel is implemented in Modula-II and presently operates on an IBM PC.

  8. Interactive and Multimedia Contents Associated with a System for Computer-Aided Assessment

    ERIC Educational Resources Information Center

    Paiva, Rui C.; Ferreira, Milton S.; Mendes, Ana G.; Eusébio, Augusto M. J.

    2015-01-01

    This article presents a research study addressing the development, implementation, evaluation, and use of Interactive Modules for Online Training (MITO) of mathematics in higher education. This work was carried out in the context of the MITO project, which combined several features of the learning and management system Moodle, the computer-aided…

  9. Computer-Aided Authoring System (AUTHOR) User's Guide. Volume I. Final Report.

    ERIC Educational Resources Information Center

    Guitard, Charles R.

    This user's guide for AUTHOR, an automatic authoring system which produces programmed texts for teaching symbol recognition, provides detailed instructions to help the user construct and enter the information needed to create the programmed text, run the AUTHOR program, and edit the automatically composed paper. Major sections describe steps in…

  10. Manned space station environmental control and life support system computer-aided technology assessment program

    NASA Technical Reports Server (NTRS)

    Hall, J. B., Jr.; Pickett, S. J.; Sage, K. H.

    1984-01-01

    A computer program for assessing manned space station environmental control and life support systems technology is described. The methodology, mission model parameters, evaluation criteria, and data base for 17 candidate technologies for providing metabolic oxygen and water to the crew are discussed. Examples are presented which demonstrate the capability of the program to evaluate candidate technology options for evolving space station requirements.

  11. Computer-Aided Systems Engineering for Flight Research Projects Using a Workgroup Database

    NASA Technical Reports Server (NTRS)

    Mizukami, Masahi

    2004-01-01

    An online systems engineering tool for flight research projects has been developed through the use of a workgroup database. Capabilities are implemented for typical flight research systems engineering needs in document library, configuration control, hazard analysis, hardware database, requirements management, action item tracking, project team information, and technical performance metrics. Repetitive tasks are automated to reduce workload and errors. Current data and documents are instantly available online and can be worked on collaboratively. Existing forms and conventional processes are used, rather than inventing or changing processes to fit the tool. An integrated tool set offers advantages by automatically cross-referencing data, minimizing redundant data entry, and reducing the number of programs that must be learned. With a simplified approach, significant improvements are attained over existing capabilities for minimal cost. By using a workgroup-level database platform, personnel most directly involved in the project can develop, modify, and maintain the system, thereby saving time and money. As a pilot project, the system has been used to support an in-house flight experiment. Options are proposed for developing and deploying this type of tool on a more extensive basis.

  12. [Computer-aided implantology: Contribution of the Robodent(®) passive robotic system.

    PubMed

    Armand, S; Legac, O; Galibourg, A

    2013-08-02

    The use of the Robodent(®) passive robotic system improves the accuracy of implant placement and thus allows extending the field of indications for flapless surgical technique. Surgery can be performed with a greater operative safety and peroperative modification of the surgical protocol is possible.

  13. Performance evaluation using SYSTID time domain simulation. [computer-aid design and analysis for communication systems

    NASA Technical Reports Server (NTRS)

    Tranter, W. H.; Ziemer, R. E.; Fashano, M. J.

    1975-01-01

    This paper reviews the SYSTID technique for performance evaluation of communication systems using time-domain computer simulation. An example program illustrates the language. The inclusion of both Gaussian and impulse noise models make accurate simulation possible in a wide variety of environments. A very flexible postprocessor makes possible accurate and efficient performance evaluation.

  14. AESOP: A computer-aided design program for linear multivariable control systems

    NASA Technical Reports Server (NTRS)

    Lehtinen, B.; Geyser, L. C.

    1982-01-01

    An interactive computer program (AESOP) which solves quadratic optimal control and is discussed. The program can also be used to perform system analysis calculations such as transient and frequency responses, controllability, observability, etc., in support of the control and filter design computations.

  15. The Development of Computer-Aided Careers Guidance Systems: A Response to Closs.

    ERIC Educational Resources Information Center

    Pierce-Price, R. P.; Corscaden, J. S.

    1994-01-01

    Responds to Closs' (1994) article concerning the project management concerns of the UK PROSPECT system. Suggests that the problems encountered in the implementation of UK PROSPECT were not caused by project management, but were, as suggested by Watts (1993), economic and political in nature. (JPS)

  16. Designing Intelligent Computer Aided Instruction Systems with Integrated Knowledge Representation Schemes

    DTIC Science & Technology

    1990-06-01

    for De- velopment of ICAI," Computers in Human Behavior , v. 3, 1987. Seidel, R. J., Park, 0.., and Perez, R. S., "Expertise of ICAI. Development...Require- ments," Computers in Human Behavior , v. 4, 1988. Sleeman, D., "Intellhent Tutoring Systems: A Review," School of Education and De- partment of

  17. Computer-aided detection of lung cancer: combining pulmonary nodule detection systems with a tumor risk prediction model

    NASA Astrophysics Data System (ADS)

    Setio, Arnaud A. A.; Jacobs, Colin; Ciompi, Francesco; van Riel, Sarah J.; Winkler Wille, Mathilde M.; Dirksen, Asger; van Rikxoort, Eva M.; van Ginneken, Bram

    2015-03-01

    Computer-Aided Detection (CAD) has been shown to be a promising tool for automatic detection of pulmonary nodules from computed tomography (CT) images. However, the vast majority of detected nodules are benign and do not require any treatment. For effective implementation of lung cancer screening programs, accurate identification of malignant nodules is the key. We investigate strategies to improve the performance of a CAD system in detecting nodules with a high probability of being cancers. Two strategies were proposed: (1) combining CAD detections with a recently published lung cancer risk prediction model and (2) the combination of multiple CAD systems. First, CAD systems were used to detect the nodules. Each CAD system produces markers with a certain degree of suspicion. Next, the malignancy probability was automatically computed for each marker, given nodule characteristics measured by the CAD system. Last, CAD degree of suspicion and malignancy probability were combined using the product rule. We evaluated the method using 62 nodules which were proven to be malignant cancers, from 180 scans of the Danish Lung Cancer Screening Trial. The malignant nodules were considered as positive samples, while all other findings were considered negative. Using a product rule, the best proposed system achieved an improvement in sensitivity, compared to the best individual CAD system, from 41.9% to 72.6% at 2 false positives (FPs)/scan and from 56.5% to 88.7% at 8 FPs/scan. Our experiment shows that combining a nodule malignancy probability with multiple CAD systems can increase the performance of computerized detection of lung cancer.

  18. Computer-Aided Design and Analysis of Digital Guidance and Control Systems.

    DTIC Science & Technology

    1983-07-01

    Relationship Between a and z For continuous systems, one often associates certain behavior for different pole locations in the s-plane: oscillatory...eST relationship in the denominators of all the table entries. Figure 2.2 shows the mapping of lines of constant damping, , and natural frequency, w...plane represents many frequencies separated by w . Physically, this is because many different signals can have the same samples and mathematically

  19. Concept Study of the Computer-Aided ARTEP (Army Training and Evaluation Program) Production System (CAPS)

    DTIC Science & Technology

    1985-07-01

    PRODUCTION SYSTEM (CAPS) 6. PERFORMING ORG . REPORT NUMBER 7. AUTHOR(.) a. CONTRACT OR GRANT NUMBER(&) Bloedorn, G. W., Crooks, W. H., Merrill, M. D...rll j:; ItrlCCT Keg: Primar i.~ISxNCn ~i!~iiii~ii~iL~;i!Jii TTin i RNN FIGRE55 CPSItraiv Ipat iara SM S~xST d 130 x IT < - - - - -. - Primary Data Entry

  20. An Expert System in C for Computer-Aided Digital Circuit Design.

    DTIC Science & Technology

    1989-06-01

    is reported in Wagner’s thesis (Wagner,87). 2 - 4 Current Technology The current technology available in the market is limited. Wagner pointed out two...suitable to be used in codification of an expert system. The commercial packages available in the market do not fill the needs of AFIT, due in part to...B.S.) degree and from ITA - Instituto Tecnologico de Aeronautica ( Aeronautical Institute of Technology), Sao Paulo, Brazil in 1983 with a B.S degree

  1. CADS - A Computer Aided Design System. Volume 3. Program Maintenance Manal.

    DTIC Science & Technology

    1986-10-01

    from our mailing list, or if the addressee is no longer employed by your organization please notify AFWAL/ FIBRA , W-PAFB, OH 45433 to help us maintain...Wright Aeronautical Laboratories Rockwell International Air Force Systems Command (AFWAL/ FIBRA ) 6c ADDRESS t(i. State and /I1 Code) 7b. ADDRESS (City...SPONSORING Sb. OFFICE SYMBOL 9. PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (if applicable) Flight Dynamics Laboratory AFWAL/ FIBRA F33615-81-C

  2. CADS - A Computer Aided Design System. Volume 1. Final Summary Report.

    DTIC Science & Technology

    1985-12-01

    employed by your organization please notify AFWAL/ FIBRA , W-PAFB, OH 45433 to help us maintain a current mailing list". Copies of this report should not be...Systems Command (AFWAL/ FIBRA ) 6c. ADDRESS (City. State and ZIP Code) 7b. ADDRESS (City. State and ZIP Code) North American Aircraft Operations (NAAO...NUMBER ORGANIZATION (if appliaoble) Flight Dynamics Laboratory AFWAL/ FIBRA F33615-81-C-3229 -c. ADDRESS (City. State and ZIP Code) 10. SOURCE OF

  3. Development of a Shipboard Damage Control Fire Team Leader Intelligent Computer Aided Instructional Tutoring System.

    DTIC Science & Technology

    1986-06-20

    hunter, one must know about logic, probability, decision theory, and geometry [Ref. 3: p. 261]. GUIDON , teaches students diagnostic problem-solving such...using the overlay model include GUIDON [Ref. 3: p. 2671, and WEST * ( Ref. 3: p. 2541. The Fire system’s expert fire fighting knowledge is the...Handbok f Ari a Intelliaence, V.2, William KTaufmann, Inc., 4. Clancey, W.J., GUIDON , Stanford University, Palo Alto, California. 5. University of

  4. A novel computer-aided diagnosis system for breast MRI based on feature selection and ensemble learning.

    PubMed

    Lu, Wei; Li, Zhe; Chu, Jinghui

    2017-03-06

    Breast cancer is a common cancer among women. With the development of modern medical science and information technology, medical imaging techniques have an increasingly important role in the early detection and diagnosis of breast cancer. In this paper, we propose an automated computer-aided diagnosis (CADx) framework for magnetic resonance imaging (MRI). The scheme consists of an ensemble of several machine learning-based techniques, including ensemble under-sampling (EUS) for imbalanced data processing, the Relief algorithm for feature selection, the subspace method for providing data diversity, and Adaboost for improving the performance of base classifiers. We extracted morphological, various texture, and Gabor features. To clarify the feature subsets' physical meaning, subspaces are built by combining morphological features with each kind of texture or Gabor feature. We tested our proposal using a manually segmented Region of Interest (ROI) data set, which contains 438 images of malignant tumors and 1898 images of normal tissues or benign tumors. Our proposal achieves an area under the ROC curve (AUC) value of 0.9617, which outperforms most other state-of-the-art breast MRI CADx systems. Compared with other methods, our proposal significantly reduces the false-positive classification rate.

  5. COMPUTER-Aided-Control Engineering (CACE) PRimitives for Robust and Adaptive control Systems.

    DTIC Science & Technology

    1987-10-12

    factorization approach ! [see, e.g., Desoer et al. (1980), Zames (1981), Vidyasagar (1985), Doyle (1985)], which has xmade it possible to formulate and solve...34A Kalman Filtering Approach to Short- Time Fourier Analysis", ANU Report, Canberra, Australia, Feb. 1984. C.A. Desoer , i{.W. Liu, J. Murray and R...399-412, June 1980. C.A. Desoer and M. Vidyasagar, Feedback Systems: Input-Output Properties, Academic Press, 1975. J.C. Doyle and C.C. Chu (1985

  6. Digital Mammography: Development of an Advanced Computer-Aided Diagnosis System for Breast Cancer Detection

    DTIC Science & Technology

    2005-05-01

    mammography system using a 1.8 X magnification geometry. A phantom -shift method equivalent to a stereo shift angle of ±3’ relative to a central axis...determine whether spiculations are present. Therefore, ste- method for phantoms and specimens in which the object is reomammography has the potential of...crimination of crossing fibrils in stereo phantom images.4’ 5’ 10 detector distance in the object-shift geometry because the Medical Physics, Vol. 32, No. 4

  7. The adult literacy evaluator: An intelligent computer-aided training system for diagnosing adult illiterates

    NASA Technical Reports Server (NTRS)

    Yaden, David B., Jr.

    1992-01-01

    An important part of NASA's mission involves the secondary application of its technologies in the public and private sectors. One current application being developed is The Adult Literacy Evaluator, a simulation-based diagnostic tool designed to assess the operant literacy abilities of adults having difficulties in learning to read and write. Using ICAT system technology in addition to speech recognition, closed-captioned television (CCTV), live video and other state-of-the art graphics and storage capabilities, this project attempts to overcome the negative effects of adult literacy assessment by allowing the client to interact with an intelligent computer system which simulates real-life literacy activities and materials and which measures literacy performance in the actual context of its use. The specific objectives of the project are as follows: (1) To develop a simulation-based diagnostic tool to assess adults' prior knowledge about reading and writing processes in actual contexts of application; (2) to provide a profile of readers' strengths and weaknesses; and (3) to suggest instructional strategies and materials which can be used as a beginning point for remediation. In the first and developmental phase of the project, descriptions of literacy events and environments are being written and functional literacy documents analyzed for their components. Examples of literacy events and situations being considered included interactions with environmental print (e.g., billboards, street signs, commercial marquees, storefront logos, etc.), functional literacy materials (e.g., newspapers, magazines, telephone books, bills, receipts, etc.) and employment related communication (i.e., job descriptions, application forms, technical manuals, memorandums, newsletters, etc.). Each of these situations and materials is being analyzed for its literacy requirements in terms of written display (i.e., knowledge of printed forms and conventions), meaning demands (i

  8. An application of computer aided requirements analysis to a real time deep space system

    NASA Technical Reports Server (NTRS)

    Farny, A. M.; Morris, R. V.; Hartsough, C.; Callender, E. D.; Teichroew, D.; Chikofsky, E.

    1981-01-01

    The entire procedure of incorporating the requirements and goals of a space flight project into integrated, time ordered sequences of spacecraft commands, is called the uplink process. The Uplink Process Control Task (UPCT) was created to examine the uplink process and determine ways to improve it. The Problem Statement Language/Problem Statement Analyzer (PSL/PSA) designed to assist the designer/analyst/engineer in the preparation of specifications of an information system is used as a supporting tool to aid in the analysis. Attention is given to a definition of the uplink process, the definition of PSL/PSA, the construction of a PSA database, the value of analysis to the study of the uplink process, and the PSL/PSA lessons learned.

  9. Development of a Computer-aided Diagnosis System for Early Detection of Masses Using Retrospectively Detected Cancers on Prior Mammograms

    DTIC Science & Technology

    2009-06-01

    Computer-aided diagnosis of masses with full-field digital mammography,” Acad. Radiol. 9, 4–12 2002. 34D. Gur, J. S. Stalder, L. A. Hardesty , B. Zheng, J...A. Hardesty , W. R. Poller, R. Shah, and L. Wallace, “Changes in breast cancer detection and mammography recall rates after the introduction of a...Stalder, L. A. Hardesty , B. Zheng, J. H. Sumkin, D. M. Chough, B. E. Shindel, and H. E. Rockette, “Computer-aided detection performance in mammographic

  10. Computer aided approximation of flow rate through systemic-pulmonary arterial shunts (SPAS).

    PubMed

    Vennemann, Peter; Montag, Michael; Peters, Franz; Merzkirch, Wolfgang

    2012-02-22

    The discrimination of flow rates through bronchial arteries that are affected by pathological SPAS today still happens solely qualitatively. A reproducible quantification of flow rates, however, would enable the comprehension of phenomena like the intensified shunt perfusion seen in cases of chronic inflammations or the characterization of SPAS that may cause cardiovascular problems. A computational program is developed, that allows the modeling of individual bronchial arteries on the basis of the information provided by angiography. Angiographic images are available from the standard clinical assessment of SPAS. The flow through continuous and geometrically measurable vessel segments and SPAS is given by the law of Hagen-Poiseuille. The discharge through healthy branches is calculated by means of allometric scaling laws. The simulation results are verified by flow experiments in artificial vessel networks made of glass and PE tubing. The experimental set-up mimics realistic, pulsating pressure and flow conditions. When applied to the artificial vessel networks, the model described herein provides results for the volumetric flow rate that differ from values measured in laboratory experiments by <6%. The computer model is also applied to real angiographic images. Due to inaccuracies during the deduction of the geometry and due to necessary simplifications of the model, we expect significant deviations between calculated and real flow rates in bronchial systems. Nevertheless, the presented method enables the physician to objectively estimate the order of magnitude of volumetric flow through individual SPAS fairly independently from his experience and without the need of measurements additional to the mandatory angiography.

  11. Computer Aided Design of Microwave Front-End Components and Antennas for Ultrawideband Systems

    NASA Astrophysics Data System (ADS)

    Almalkawi, Mohammad J.

    order to maintain high performance of conventional rectangular waveguides in planar form, substrate integrated waveguide (SIW) technology was utilized. A design of single-band dual-mode SIW filters with improved upper stopband performance and a design of dual-band dual mode SIW filters are introduced. Compact evanescent-mode SIW filters are also realized for low frequency applications and for better stopband performance. In addition, a novel tuning solution for planar SIW reconfigurable filters is also presented. Tunablity of the reconfigurable filter is achieved by adjusting dc-magnetic bias applied to the ferrite material. The new tuning technique leads to a dramatic reduction in complexity for the external control system.

  12. Computer-Aided Remote Driving

    NASA Technical Reports Server (NTRS)

    Wilcox, Brian H.

    1994-01-01

    System for remote control of robotic land vehicle requires only small radio-communication bandwidth. Twin video cameras on vehicle create stereoscopic images. Operator views cross-polarized images on two cathode-ray tubes through correspondingly polarized spectacles. By use of cursor on frozen image, remote operator designates path. Vehicle proceeds to follow path, by use of limited degree of autonomous control to cope with unexpected conditions. System concept, called "computer-aided remote driving" (CARD), potentially useful in exploration of other planets, military surveillance, firefighting, and clean-up of hazardous materials.

  13. To Propose a Reviewer Dispatching Algorithm for Networked Peer Assessment System.

    ERIC Educational Resources Information Center

    Liu, Eric Zhi-Feng

    2005-01-01

    Despite their increasing availability on the Internet, networked peer assessment systems (1-5) lack feasible automatic dispatching algorithm of student's assignments and ultimately inhibit the effectiveness of peer assessment. Therefore, this study presents a reviewer dispatching algorithm capable of supporting networked peer assessment system in…

  14. Measurement of myocardial perfusion and infarction size using computer-aided diagnosis system for myocardial contrast echocardiography.

    PubMed

    Du, Guo-Qing; Xue, Jing-Yi; Guo, Yanhui; Chen, Shuang; Du, Pei; Wu, Yan; Wang, Yu-Hang; Zong, Li-Qiu; Tian, Jia-Wei

    2015-09-01

    Proper evaluation of myocardial microvascular perfusion and assessment of infarct size is critical for clinicians. We have developed a novel computer-aided diagnosis (CAD) approach for myocardial contrast echocardiography (MCE) to measure myocardial perfusion and infarct size. Rabbits underwent 15 min of coronary occlusion followed by reperfusion (group I, n = 15) or 60 min of coronary occlusion followed by reperfusion (group II, n = 15). Myocardial contrast echocardiography was performed before and 7 d after ischemia/reperfusion, and images were analyzed with the CAD system on the basis of eliminating particle swarm optimization clustering analysis. The myocardium was quickly and accurately detected using contrast-enhanced images, myocardial perfusion was quantitatively calibrated and a color-coded map calibrated by contrast intensity and automatically produced by the CAD system was used to outline the infarction region. Calibrated contrast intensity was significantly lower in infarct regions than in non-infarct regions, allowing differentiation of abnormal and normal myocardial perfusion. Receiver operating characteristic curve analysis documented that -54-pixel contrast intensity was an optimal cutoff point for the identification of infarcted myocardium with a sensitivity of 95.45% and specificity of 87.50%. Infarct sizes obtained using myocardial perfusion defect analysis of original contrast images and the contrast intensity-based color-coded map in computerized images were compared with infarct sizes measured using triphenyltetrazolium chloride staining. Use of the proposed CAD approach provided observers with more information. The infarct sizes obtained with myocardial perfusion defect analysis, the contrast intensity-based color-coded map and triphenyltetrazolium chloride staining were 23.72 ± 8.41%, 21.77 ± 7.8% and 18.21 ± 4.40% (% left ventricle) respectively (p > 0.05), indicating that computerized myocardial contrast echocardiography can

  15. Computer-aided diagnosis workstation and teleradiology network system for chest diagnosis using the web medical image conference system with a new information security solution

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2010-03-01

    Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis

  16. Computer aided surface representation

    SciTech Connect

    Barnhill, R.E.

    1989-02-09

    The central research problem of this project is the effective representation and display of surfaces, interpolating to given information, in three or more dimensions. In a typical problem, we wish to create a surface from some discrete information. If this information is itself on another surface, the problem is to determine a surface defined on a surface,'' which is discussed below. Often, properties of an already constructed surface are desired: such geometry processing'' is described below. The Summary of Proposed Research from our original proposal describes the aims of this research project. This Summary and the Table of Contents from the original proposal are enclosed as an Appendix to this Progress Report. The broad sweep from constructive mathematics through algorithms and computer graphics displays is utilized in the research. The wide range of activity, directed in both theory and applications, makes this project unique. Last month in the first Ardent Titan delivered in the State of Arizona came to our group, funded by the DOE and Arizona State University. Although the Titan is a commercial product, its newness requires our close collaboration with Ardent to maximize results. During the past year, four faculty members and several graduate research assistants have worked on this DOE project. The gaining of new professionals is an important aspect of this project. A listing of the students and their topics is given in the Appendix. The most significant publication during the past year is the book, Curves and Surfaces for Computer Aided Geometric Design, by Dr. Gerald Farin. This 300 page volume helps fill a considerable gap in the subject and includes many new results on Bernstein-Bezier curves and surfaces.

  17. Integrated Computer-Aided Drafting Instruction (ICADI).

    ERIC Educational Resources Information Center

    Chen, C. Y.; McCampbell, David H.

    Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…

  18. Computer-Aided Design in Further Education.

    ERIC Educational Resources Information Center

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  19. Reliability of a Swedish pre-hospital dispatch system in prioritizing patients.

    PubMed

    Ek, Bosse; Edström, Pontus; Toutin, Anders; Svedlund, Marianne

    2013-04-01

    The need of emergency help often begins with a call to a dispatch center. The operator uses a medical index to prioritize dispatches. Since the resources of ambulances are limited, it is important that the priority grading decided by the operator at the dispatch center is as adequate as possible. In the county of Jamtland in Sweden, a system for triage named METTS-A (Medical Emergency Triage and Treatment System-A) has been in use since 2009, when the patient is coded according to priority level. The aim of this study was to analyse the sensitivity and specificity of the priority grading made by the dispatch center in comparison with the METTS-A priority assessed by the ambulance nurse. Statistics from a data-base in northern Sweden were analyzed. The material covered every ambulance that was dispatched, 6986 times during the period of data collecting. The results show a high sensitivity but low specificity in the dispatch system. The results also indicate that over prioritization exists since most of the patients with a high acute need of an ambulance are correctly identified, while many patients without that need are also given a high priority ambulance service. Therefore the conclusions were that both over- and under prioritizations were made.

  20. Computer Aided Modeling and Post Processing with NASTRAN Analysis

    NASA Technical Reports Server (NTRS)

    Boroughs, R. R.

    1984-01-01

    Computer aided engineering systems are invaluable tools in performing NASTRAN finite element analysis. These techniques are implemented in both the pre-processing and post-processing phases of the NASTRAN analysis. The finite element model development, or pre-processing phase, was automated with a computer aided modeling program called Supertabl, and the review and interpretation of the results of the NASTRAN analysis, or post-processing phase, was automated with a computer aided plotting program called Output Display. An intermediate program, Nasplot, which was developed in-house, has also helped to cut down on the model checkout time and reduce errors in the model. An interface has been established between the finite element computer aided engineering system and the Learjet computer aided design system whereby data can be transferred back and forth between the two. These systems have significantly improved productivity and the ability to perform NASTRAN analysis in response to product development requests.

  1. Optimal Real-time Dispatch for Integrated Energy Systems

    SciTech Connect

    Firestone, Ryan Michael

    2007-05-31

    This report describes the development and application of a dispatch optimization algorithm for integrated energy systems (IES) comprised of on-site cogeneration of heat and electricity, energy storage devices, and demand response opportunities. This work is intended to aid commercial and industrial sites in making use of modern computing power and optimization algorithms to make informed, near-optimal decisions under significant uncertainty and complex objective functions. The optimization algorithm uses a finite set of randomly generated future scenarios to approximate the true, stochastic future; constraints are included that prevent solutions to this approximate problem from deviating from solutions to the actual problem. The algorithm is then expressed as a mixed integer linear program, to which a powerful commercial solver is applied. A case study of United States Postal Service Processing and Distribution Centers (P&DC) in four cities and under three different electricity tariff structures is conducted to (1) determine the added value of optimal control to a cogeneration system over current, heuristic control strategies; (2) determine the value of limited electric load curtailment opportunities, with and without cogeneration; and (3) determine the trade-off between least-cost and least-carbon operations of a cogeneration system. Key results for the P&DC sites studied include (1) in locations where the average electricity and natural gas prices suggest a marginally profitable cogeneration system, optimal control can add up to 67% to the value of the cogeneration system; optimal control adds less value in locations where cogeneration is more clearly profitable; (2) optimal control under real-time pricing is (a) more complicated than under typical time-of-use tariffs and (b) at times necessary to make cogeneration economic at all; (3) limited electric load curtailment opportunities can be more valuable as a compliment to the cogeneration system than alone; and

  2. Bridging the integration gap between imaging and information systems: a uniform data concept for content-based image retrieval in computer-aided diagnosis.

    PubMed

    Welter, Petra; Riesmeier, Jörg; Fischer, Benedikt; Grouls, Christoph; Kuhl, Christiane; Deserno, Thomas M

    2011-01-01

    It is widely accepted that content-based image retrieval (CBIR) can be extremely useful for computer-aided diagnosis (CAD). However, CBIR has not been established in clinical practice yet. As a widely unattended gap of integration, a unified data concept for CBIR-based CAD results and reporting is lacking. Picture archiving and communication systems and the workflow of radiologists must be considered for successful data integration to be achieved. We suggest that CBIR systems applied to CAD should integrate their results in a picture archiving and communication systems environment such as Digital Imaging and Communications in Medicine (DICOM) structured reporting documents. A sample DICOM structured reporting template adaptable to CBIR and an appropriate integration scheme is presented. The proposed CBIR data concept may foster the promulgation of CBIR systems in clinical environments and, thereby, improve the diagnostic process.

  3. Proceedings of the NATO-Advanced Study Institute on Computer Aided Analysis of Rigid and Flexible Mechanical Systems. Volume 1: Main lectures

    NASA Astrophysics Data System (ADS)

    Pereira, Manuel S.; Ambrosio, Jorge A. C.

    1993-07-01

    During the last few years, major scientific progress has been achieved in fields related to computer aided analysis of multibody systems. In view of this progress and recent developments of computer hardware and general purpose software, there is a need to access the current state of art and results from different schools of thought, with the objective of focussing trends in future research. Going back to 1983 when an important NATO-NSF-ARO Advanced Study Institute on Computer Aided Analysis and Optimization of Mechanical Systems was held at the University of Iowa, one may notice that less then 10 years ago the state of art was mainly dwelling on rigid body dynamics. The interest in the dynamic simulation of mechanical systems has steadily increased in recent years coming mainly from the aerospace and automative industries. The development of multibody system analysis formulations have been more recently motivated with the need to include several features such as: real-time simulation capabilities, highly non-linear control devices, work space path planing, active control of machine flexibilities and reliability and accuracy in the analysis results. The need for accurate and efficient analysis tools for design of large and lightweight mechanical systems has driven many research groups in the challenging problem of flexible systems with an increasing interaction with finite element methodologies. Basic approaches to mechanical systems dynamic analysis have recently been presented in several new text books. These publications demonstrate that both recursive and absolute methods still have their proponents to resolve the redundancy encountered in most mechanical systems.

  4. A Computer-Aided Diagnosis System for Dynamic Contrast-Enhanced MR Images Based on Level Set Segmentation and ReliefF Feature Selection

    PubMed Central

    Zhu, Dongmei; Li, Li

    2015-01-01

    This study established a fully automated computer-aided diagnosis (CAD) system for the classification of malignant and benign masses via breast magnetic resonance imaging (BMRI). A breast segmentation method consisting of a preprocessing step to identify the air-breast interfacing boundary and curve fitting for chest wall line (CWL) segmentation was included in the proposed CAD system. The Chan-Vese (CV) model level set (LS) segmentation method was adopted to segment breast mass and demonstrated sufficiently good segmentation performance. The support vector machine (SVM) classifier with ReliefF feature selection was used to merge the extracted morphological and texture features into a classification score. The accuracy, sensitivity, and specificity measurements for the leave-half-case-out resampling method were 92.3%, 98.2%, and 76.2%, respectively. For the leave-one-case-out resampling method, the measurements were 90.0%, 98.7%, and 73.8%, respectively. PMID:25628755

  5. Computer-Aided Writing.

    DTIC Science & Technology

    1988-04-01

    Adapter IBM ............. International Business Machines K ............... Kilo (thousand) LAN ............. Local Area Network M ............... Mega ...and Review Software ................. 18 Other ................................................ 19 Communications and Networking Systems...Defense Data Network DOS ............. Disk Operating System DTP ............. Desktop Publishing EGA ............. Enhanced Graphics

  6. Optimal Dispatch of Unreliable Electric Grid-Connected Diesel Generator-Battery Power Systems

    NASA Astrophysics Data System (ADS)

    Xu, D.; Kang, L.

    2015-06-01

    Diesel generator (DG)-battery power systems are often adopted by telecom operators, especially in semi-urban and rural areas of developing countries. Unreliable electric grids (UEG), which have frequent and lengthy outages, are peculiar to these regions. DG-UEG-battery power system is an important kind of hybrid power system. System dispatch is one of the key factors to hybrid power system integration. In this paper, the system dispatch of a DG-UEG-lead acid battery power system is studied with the UEG of relatively ample electricity in Central African Republic (CAR) and UEG of poor electricity in Congo Republic (CR). The mathematical models of the power system and the UEG are studied for completing the system operation simulation program. The net present cost (NPC) of the power system is the main evaluation index. The state of charge (SOC) set points and battery bank charging current are the optimization variables. For the UEG in CAR, the optimal dispatch solution is SOC start and stop points 0.4 and 0.5 that belong to the Micro-Cycling strategy and charging current 0.1 C. For the UEG in CR, the optimal dispatch solution is of 0.1 and 0.8 that belongs to the Cycle-Charging strategy and 0.1 C. Charging current 0.1 C is suitable for both grid scenarios compared to 0.2 C. It makes the dispatch strategy design easier in commercial practices that there are a few very good candidate dispatch solutions with system NPC values close to that of the optimal solution for both UEG scenarios in CAR and CR.

  7. Computer-aided modeling and prediction of performance of the modified Lundell class of alternators in space station solar dynamic power systems

    NASA Technical Reports Server (NTRS)

    Demerdash, Nabeel A. O.; Wang, Ren-Hong

    1988-01-01

    The main purpose of this project is the development of computer-aided models for purposes of studying the effects of various design changes on the parameters and performance characteristics of the modified Lundell class of alternators (MLA) as components of a solar dynamic power system supplying electric energy needs in the forthcoming space station. Key to this modeling effort is the computation of magnetic field distribution in MLAs. Since the nature of the magnetic field is three-dimensional, the first step in the investigation was to apply the finite element method to discretize volume, using the tetrahedron as the basic 3-D element. Details of the stator 3-D finite element grid are given. A preliminary look at the early stage of a 3-D rotor grid is presented.

  8. Computer-Aided Geometry Modeling

    NASA Technical Reports Server (NTRS)

    Shoosmith, J. N. (Compiler); Fulton, R. E. (Compiler)

    1984-01-01

    Techniques in computer-aided geometry modeling and their application are addressed. Mathematical modeling, solid geometry models, management of geometric data, development of geometry standards, and interactive and graphic procedures are discussed. The applications include aeronautical and aerospace structures design, fluid flow modeling, and gas turbine design.

  9. Computer Aided Tests.

    ERIC Educational Resources Information Center

    Steinke, Elisabeth

    An approach to using the computer to assemble German tests is described. The purposes of the system would be: (1) an expansion of the bilingual lexical memory bank to list and store idioms of all degrees of difficulty, with frequency data and with complete and sophisticated retrieval possibility for assembly; (2) the creation of an…

  10. Computer aided manipulator control

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.; Zawacki, R. L.

    1980-01-01

    This paper describes the hardware and software system of a dedicated mini- and microcomputer network developed at the JPL teleoperator project to aid the operator in real-time control of remote manipulators. The operator can be in series or in parallel with the control computer during operation. The purpose of the project is to develop, demonstrate and evaluate advanced supervisory control concepts and techniques for space applications. The paper concludes with a brief outline of future development plans and issues.

  11. Issues of a Computer-Aided Design of Hydraulic Jacks

    NASA Astrophysics Data System (ADS)

    Averchenkov, V. I.; Averchenkov, A. V.; Kolyakinand, V. V.; Orekhov, O. D.

    2016-04-01

    The article deals with the issues of a computer-aided design of hydraulic equipment, namely hydraulic jacks. Design principles of the hydraulic jack CAD system are described. In addition, the possibilities for the system improvement and expansion are considered.

  12. Assessing the performance of four different categories of histological criteria in brain tumours grading by means of a computer-aided diagnosis image analysis system.

    PubMed

    Kostopoulos, S; Konstandinou, C; Sidiropoulos, K; Ravazoula, P; Kalatzis, I; Asvestas, P; Cavouras, D; Glotsos, D

    2015-10-01

    Brain tumours are considered one of the most lethal and difficult to treat forms of cancer, with unknown aetiology and lack of any realistic screening. In this study, we examine, whether the combination of descriptive criteria, used by expert histopathologists in assessing histologic tissue samples, and quantitative image analysis features may improve the diagnostic accuracy of brain tumour grading. Data comprised 61 cases of brain cancers (astrocytomas, oligodendrogliomas, meningiomas) collected from the archives of the University Hospital of Patras, Greece. Incorporating physician's descriptive criteria and image analysis's quantitative features into a discriminant function, a computer-aided diagnosis system was designed for discriminating low-grade from high-grade brain tumours. Physician's descriptive features, when solely used in the system, proved of high discrimination accuracy (93.4%). When verbal descriptive features were combined with quantitative image analysis features in the system, discrimination accuracy improved to 98.4%. The generalization of the proposed system to unseen data converged to an overall prediction accuracy of 86.7% ± 5.4%. Considering that histological grading affects treatment selection and diagnostic errors may be notable in clinical practice, the utilization of the proposed system may safeguard against diagnostic misinterpretations in every day clinical practice.

  13. Computer-aided design development transition for IPAD environment

    NASA Technical Reports Server (NTRS)

    Owens, H. G.; Mock, W. D.; Mitchell, J. C.

    1980-01-01

    The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.

  14. Computer-aided screening system for cervical precancerous cells based on field emission scanning electron microscopy and energy dispersive x-ray images and spectra

    NASA Astrophysics Data System (ADS)

    Jusman, Yessi; Ng, Siew-Cheok; Hasikin, Khairunnisa; Kurnia, Rahmadi; Osman, Noor Azuan Bin Abu; Teoh, Kean Hooi

    2016-10-01

    The capability of field emission scanning electron microscopy and energy dispersive x-ray spectroscopy (FE-SEM/EDX) to scan material structures at the microlevel and characterize the material with its elemental properties has inspired this research, which has developed an FE-SEM/EDX-based cervical cancer screening system. The developed computer-aided screening system consisted of two parts, which were the automatic features of extraction and classification. For the automatic features extraction algorithm, the image and spectra of cervical cells features extraction algorithm for extracting the discriminant features of FE-SEM/EDX data was introduced. The system automatically extracted two types of features based on FE-SEM/EDX images and FE-SEM/EDX spectra. Textural features were extracted from the FE-SEM/EDX image using a gray level co-occurrence matrix technique, while the FE-SEM/EDX spectra features were calculated based on peak heights and corrected area under the peaks using an algorithm. A discriminant analysis technique was employed to predict the cervical precancerous stage into three classes: normal, low-grade intraepithelial squamous lesion (LSIL), and high-grade intraepithelial squamous lesion (HSIL). The capability of the developed screening system was tested using 700 FE-SEM/EDX spectra (300 normal, 200 LSIL, and 200 HSIL cases). The accuracy, sensitivity, and specificity performances were 98.2%, 99.0%, and 98.0%, respectively.

  15. Survey of Intelligent Computer-Aided Training

    NASA Technical Reports Server (NTRS)

    Loftin, R. B.; Savely, Robert T.

    1992-01-01

    Intelligent Computer-Aided Training (ICAT) systems integrate artificial intelligence and simulation technologies to deliver training for complex, procedural tasks in a distributed, workstation-based environment. Such systems embody both the knowledge of how to perform a task and how to train someone to perform that task. This paper briefly reviews the antecedents of ICAT systems and describes the approach to their creation developed at the NASA Lyndon B. Johnson Space Center. In addition to the general ICAT architecture, specific ICAT applications that have been or are currently under development are discussed. ICAT systems can offer effective solutions to a number of training problems of interest to the aerospace community.

  16. The adaptive computer-aided diagnosis system based on tumor sizes for the classification of breast tumors detected at screening ultrasound.

    PubMed

    Moon, Woo Kyung; Chen, I-Ling; Chang, Jung Min; Shin, Sung Ui; Lo, Chung-Ming; Chang, Ruey-Feng

    2017-04-01

    Screening ultrasound (US) is increasingly used as a supplement to mammography in women with dense breasts, and more than 80% of cancers detected by US alone are 1cm or smaller. An adaptive computer-aided diagnosis (CAD) system based on tumor size was proposed to classify breast tumors detected at screening US images using quantitative morphological and textural features. In the present study, a database containing 156 tumors (78 benign and 78 malignant) was separated into two subsets of different tumor sizes (<1cm and ⩾1cm) to explore the improvement in the performance of the CAD system. After adaptation, the accuracies, sensitivities, specificities and Az values of the CAD for the entire database increased from 73.1% (114/156), 73.1% (57/78), 73.1% (57/78), and 0.790 to 81.4% (127/156), 83.3% (65/78), 79.5% (62/78), and 0.852, respectively. In the data subset of tumors larger than 1cm, the performance improved from 66.2% (51/77), 68.3% (28/41), 63.9% (23/36), and 0.703 to 81.8% (63/77), 85.4% (35/41), 77.8% (28/36), and 0.855, respectively. The proposed CAD system can be helpful to classify breast tumors detected at screening US.

  17. Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics.

    PubMed

    Patrizi, Alfredo; Pennestrì, Ettore; Valentini, Pier Paolo

    2016-01-01

    The paper deals with the comparison between a high-end marker-based acquisition system and a low-cost marker-less methodology for the assessment of the human posture during working tasks. The low-cost methodology is based on the use of a single Microsoft Kinect V1 device. The high-end acquisition system is the BTS SMART that requires the use of reflective markers to be placed on the subject's body. Three practical working activities involving object lifting and displacement have been investigated. The operational risk has been evaluated according to the lifting equation proposed by the American National Institute for Occupational Safety and Health. The results of the study show that the risk multipliers computed from the two acquisition methodologies are very close for all the analysed activities. In agreement to this outcome, the marker-less methodology based on the Microsoft Kinect V1 device seems very promising to promote the dissemination of computer-aided assessment of ergonomics while maintaining good accuracy and affordable costs. PRACTITIONER’S SUMMARY: The study is motivated by the increasing interest for on-site working ergonomics assessment. We compared a low-cost marker-less methodology with a high-end marker-based system. We tested them on three different working tasks, assessing the working risk of lifting loads. The two methodologies showed comparable precision in all the investigations.

  18. A schema for knowledge representation and its implementation in a computer-aided design and manufacturing system

    SciTech Connect

    Tamir, D.E.

    1989-01-01

    Modularity in the design and implementation of expert systems relies upon cooperation among the expert systems and communication of knowledge between them. A prerequisite for an effective modular approach is some standard for knowledge representation to be used by the developers of the different modules. In this work the author presents a schema for knowledge representation, and apply this schema in the design of a rule-based expert system. He also implements a cooperative expert system using the proposed knowledge representation method. A knowledge representation schema is a formal specification of the internal, conceptual, and external components of a knowledge base, each specified in a separate schema. The internal schema defines the structure of a knowledge base, the conceptual schema defines the concepts, and the external schema formalizes the pragmatics of a knowledge base. The schema is the basis for standardizing knowledge representation systems and it is used in the various phases of design and specification of the knowledge base. A new model of knowledge representation based on a pattern recognition interpretation of implications is developed. This model implements the concept of linguistic variables and can, therefore, emulate human reasoning with linguistic imprecision. The test case for the proposed schema of knowledge representation is a system is a cooperative expert system composed of two expert systems. This system applies a pattern recognition interpretation of a generalized one-variable implication with linguistic variables.

  19. Computer-aided laser-optoelectronic OPTEL 3D measurement systems of complex-shaped object geometry

    NASA Astrophysics Data System (ADS)

    Galiulin, Ravil M.; Galiulin, Rishat M.; Bakirov, J. M.; Bogdanov, D. R.; Shulupin, C. O.; Khamitov, D. H.; Khabibullin, M. G.; Pavlov, A. F.; Ryabov, M. S.; Yamaliev, K. N.

    1996-03-01

    Technical characteristics, advantages and applications of automated optoelectronic measuring systems designed at the Regional Interuniversity Optoelectronic Systems Laboratory ('OPTEL') of Ufa State Aviation Technical University are given. The suggested range of systems is the result of the long-term scientific and research experiments, work on design and introduction work. The system can be applied in industrial development and research, in the field of high precision measurement of geometrical parameters in aerospace, robotic, etc., where non-contact and fast measurements of complicated shape objects made of various materials including brittle and plastic articles are required.

  20. Design analysis and computer-aided performance evaluation of shuttle orbiter electrical power system. Volume 2: SYSTID user's guide

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The manual for the use of the computer program SYSTID under the Univac operating system is presented. The computer program is used in the simulation and evaluation of the space shuttle orbiter electric power supply. The models described in the handbook are those which were available in the original versions of SYSTID. The subjects discussed are: (1) program description, (2) input language, (3) node typing, (4) problem submission, and (5) basic and power system SYSTID libraries.

  1. Solving rational matrix equations in the state space with applications to computer-aided control-system design

    NASA Technical Reports Server (NTRS)

    Packard, A. K.; Sastry, S. S.

    1986-01-01

    A method of solving a class of linear matrix equations over various rings is proposed, using results from linear geometric control theory. An algorithm, successfully implemented, is presented, along with non-trivial numerical examples. Applications of the method to the algebraic control system design methodology are discussed.

  2. [Evaluation of a Computer-Aided Microscope System and Its Anti-Nuclear Antibody Test Kit for Indirect Immunofluorescence Assay].

    PubMed

    Hayashi, Nobuhide; Saegusa, Jun; Uto, Kenichi; Oyabu, Chinami; Saito, Toshiharu; Sato, Itsuko; Kawano, Seiji; Kumagai, Shunichi

    2016-02-01

    Antinuclear antibody (ANA) testing is indispensable for diagnosing and understanding clinical conditions of autoimmune diseases. The indirect immunofluorescence assay (IFA) is the gold standard for ANA screening, and it can detect more than 100 different antibodies, such as anti-PCNA as well as anti-cytoplasmic antibodies. However, complicated procedures of conventional IFA and visual interpretation require highly skilled laboratory staff. This study evaluates the capability, characteristics, and applicability of the recently developed ANA detection system (EUROPattern Cosmic IFA System, EPA) using HEp20-10 cells and the automated pattern recognition microscope. Findings using EPA and conventional methods were compared in 282 sera obtained from connective tissue disease patients and 250 sera from healthy individuals. The concordance of the positivity rate, antibody titer (within +/- 1 tube difference), and the accurate recognition rate of ANA patterns between the automated EPA method and the microscopic judgement of the EPA image by eye was 98.9, 97.4, and 55.3%, respectively. The EPA method showed concordance of the positivity rate as high as 93.3% and concordance of the antibody titer as high as 94.0% (within +/- 1 titer) compared with the conventional method. Regarding the four typical patterns of ANA (homogeneous, speckled, nucleolar, and centromere), large differences between the EPA and conventional methods were not observed, and the rate of concordance between the final EPA result and the conventional method was from 94.1 to 100%. The positivity rate of ANA using the EPA and conventional methods showed marked agreement among the six connective tissue diseases (SLE, MCTD, SSc, PM/DM, and SS) and healthy individuals. Although the EPA system is not considered a complete system and laboratory staff should verify the results, it is a useful system for routine ANA analysis because it contributes to ANA standardization and an efficient workflow.

  3. Investigation of CPD and HMDS sample preparation techniques for cervical cells in developing computer-aided screening system based on FE-SEM/EDX.

    PubMed

    Jusman, Yessi; Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system.

  4. Design analysis and computer-aided performance evaluation of shuttle orbiter electrical power system. Volume 1: Summary

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Studies were conducted to develop appropriate space shuttle electrical power distribution and control (EPDC) subsystem simulation models and to apply the computer simulations to systems analysis of the EPDC. A previously developed software program (SYSTID) was adapted for this purpose. The following objectives were attained: (1) significant enhancement of the SYSTID time domain simulation software, (2) generation of functionally useful shuttle EPDC element models, and (3) illustrative simulation results in the analysis of EPDC performance, under the conditions of fault, current pulse injection due to lightning, and circuit protection sizing and reaction times.

  5. A computer-aided diagnosis system using artificial intelligence for the diagnosis and characterization of thyroid nodules on ultrasound: initial clinical assessment.

    PubMed

    Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, YoungKee; Lee, Jeong Hyun

    2017-01-10

    Background We describe an initial clinical assessment of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and evaluate its performance in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Methods This prospective study protocol was reviewed and approved by the institutional review board. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant on the basis of cytopathologic or US results, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. We compared the diagnostic performance and agreement of US characteristics between experienced radiologist and the CAD system. Results In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (sensitivity: 90.7% versus 88.4%, P>0.99), but a lower specificity, and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% versus 94.9%, P=0.002; AUROC: 0.83 versus 0.92, P=0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (kappa=0.659, 0.740, 0.733, and 0.658, respectively), while margin definition showed a fair agreement (kappa=0.239). Conclusion The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the

  6. A prostate cancer computer-aided diagnosis system using multimodal magnetic resonance imaging and targeted biopsy labels

    NASA Astrophysics Data System (ADS)

    Liu, Peter; Wang, Shijun; Turkbey, Baris; Grant, Kinzya; Pinto, Peter; Choyke, Peter; Wood, Bradford J.; Summers, Ronald M.

    2013-02-01

    We propose a new method for prostate cancer classification based on supervised statistical learning methods by integrating T2-weighted, diffusion-weighted, and dynamic contrast-enhanced MRI images with targeted prostate biopsy results. In the first step of the method, all three imaging modalities are registered based on the image coordinates encoded in the DICOM images. In the second step, local statistical features are extracted in each imaging modality to capture intensity, shape, and texture information at every biopsy target. Finally, using support vector machines, supervised learning is conducted with the biopsy results to train a classification system that predicts the pathology of suspicious cancer lesions. The algorithm was tested with a dataset of 54 patients that underwent 164 targeted biopsies (58 positive, 106 negative). The proposed tri-modal MRI algorithm shows significant improvement over a similar approach that utilizes only T2-weighted MRI images (p= 0.048). The areas under the ROC curve for these methods were 0.82 (95% CI: [0.71, 0.93]) and 0.73 (95% CI: [0.55, 0.84]), respectively.

  7. Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems.

    PubMed

    Karataşli, Ozge; Kursoğlu, Pinar; Capa, Nuray; Kazazoğlu, Ender

    2011-01-01

    In this study, marginal adaptations of different copings fabricated with CAD/CAM or MAD/CAM were analysed. Celay and Zirkonzahn groups were fabricated by MAD/CAM, LAVA and DC-Zircon groups were fabricated by CAD/CAM. Casting metal copings were used as the control group. An implant abutment that was embedded in octagonal acrylic block was used to prepare the copings. Sixteen previously established points were marked and the measurements were performed with the stereomicroscope (at × 150). The marginal fit of the samples were evaluated by calculating the mean measurements of each 16 points. The statistical analysis was performed by Tukey multiple comparisons test at 95% confidence interval. The groups can be summarized as follows in terms of marginal gap, from the lowest to highest: LAVA (24.6 ± 14.0 µm)systems may not be the most important factor for marginal adaptation.

  8. Quality indexing with computer-aided lexicography

    NASA Technical Reports Server (NTRS)

    Buchan, Ronald L.

    1992-01-01

    Indexing with computers is a far cry from indexing with the first indexing tool, the manual card sorter. With the aid of computer-aided lexicography, both indexing and indexing tools can provide standardization, consistency, and accuracy, resulting in greater quality control than ever before. A brief survey of computer activity in indexing is presented with detailed illustrations from NASA activity. Applications from techniques mentioned, such as Retrospective Indexing (RI), can be made to many indexing systems. In addition to improving the quality of indexing with computers, the improved efficiency with which certain tasks can be done is demonstrated.

  9. Integrated computer-aided design using minicomputers

    NASA Technical Reports Server (NTRS)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  10. Effectiveness of a computer-aided neuroanatomy program for entry-level physical therapy students: anatomy and clinical examination of the dorsal column-medial lemniscal system.

    PubMed

    McKeough, D Michael; Mattern-Baxter, Katrin; Barakatt, Edward

    2010-01-01

    The purpose of this study was to determine if a computer-aided instruction learning module improves students' knowledge of the neuroanatomy/physiology and clinical examination of the dorsal column-medial lemniscal (DCML) system. Sixty-one physical therapy students enrolled in a clinical neurology course in entry-level PT educational programs at two universities participated in the study. Students from University-1 (U1;) had not had a previous neuroanatomy course, while students from University-2 (U2;) had taken a neuroanatomy course in the previous semester. Before and after working with the learning module, students took a paper-and-pencil test on the neuroanatomy/physiology and clinical examination of the DCML system. Kruskal-Wallis one-way ANOVA and Mann-Whitney tests were used to determine if differences existed between neuroanatomy/physiology examination scores and clinical examination scores before and after taking the learning module, and between student groups based on university attended. For students from U1, neuroanatomy/physiology post-test scores improved significantly over pre-test scores (p < 0.001), while post-test scores of students from U2 did not (p = 0.60). Neuroanatomy/physiology pre-test scores from U2 were significantly better than those from U1 (p < 0.001); there was no significant difference in post-test scores (p = 0.062). Clinical examination pre-test and post-test scores from U2 were significantly better than those from U1 (p < 0.001). Clinical examination post-test scores improved significantly from the pre-test scores for both U1 (p < 0.001) and U2 (p < 0.001).

  11. Computer aided control of a mechanical arm

    NASA Technical Reports Server (NTRS)

    Derocher, W. L., Jr.; Zermuehlen, r. O.

    1979-01-01

    A method for computer-aided remote control of a six-degree-of-freedom manipulator arm involved in the on-orbit servicing of a spacecraft is presented. The control configuration features a supervisory type of control in which each of the segments of a module exchange trajectory is controlled automatically under human supervision, with manual commands to proceed to the next step and in the event of a failure or undesirable outcome. The implementation of the supervisory system is discussed in terms of necessary onboard and ground- or Orbiter-based hardware and software, and a one-g demonstration system built to allow further investigation of system operation is described. Possible applications of the system include the construction of satellite solar power systems, environmental testing and the control of heliostat solar power stations.

  12. Development of a first-responder dispatch system using a smartphone.

    PubMed

    Yonekawa, Chikara; Suzukawa, Masayuki; Yamashita, Keisuke; Kubota, Katsuaki; Yasuda, Yasuharu; Kobayashi, Akihiro; Matsubara, Hiroki; Toyokuni, Yoshiki

    2014-03-01

    We constructed a prototype community first responder (CFR) dispatch system. The system sends incident information, including a map, to the chosen CFR's mobile phone. We tested it in a simulation of 30 out-of-hospital cardiac arrest incidents which had occurred in the town of Motegi during the previous year. Thirty off-duty firefighters acted as CFRs and were sent to the same locations. The mean response time (from the CFR receiving dispatch information to arrival at the scene) was 3 min 37s faster than the actual response time in the corresponding historical control, i.e. the response time was reduced by 36% (P < 0.01). The median travel distance of the CFRs was 3.4 km and there was a positive correlation between response time and travel distance. The study showed that interactive communication between dispatcher and CFR was important for effective operation and that CFRs could reach an OHCA patient before the Emergency Medical Service arrives.

  13. Evaluation of computer-aided system design tools for SDI (Strategic Defense Initiative) Battle Management/C3 (command, control and communications) architecture development. Final report

    SciTech Connect

    Fife, D.W.; Campbell, K.; Chludzinski, J.; Corcoran, N.; Gonzalez, C.

    1987-10-01

    This IDA paper was prepared at the request of the Strategic Defense Initiative Organization. The paper documents findings of an evaluation on the capabilities of certain computer software/computer-aided software engineering (CASE) tools to provide computer-aided graphic design of Battle Management/C3 for the SDIO. Each tool (of the five selected on the basis of the best available at this time), was installed at IDA. After training by vendor tool staff, an IDA team, using a hands-on design experience determined the merits of the tools for SDI application. A comparative summary of the tools is given relative to envisaged SDI requirements and an extensive questionnaire is answered for each.

  14. Mathematical modelling in the computer-aided process planning

    NASA Astrophysics Data System (ADS)

    Mitin, S.; Bochkarev, P.

    2016-04-01

    This paper presents new approaches to organization of manufacturing preparation and mathematical models related to development of the computer-aided multi product process planning (CAMPP) system. CAMPP system has some peculiarities compared to the existing computer-aided process planning (CAPP) systems: fully formalized developing of the machining operations; a capacity to create and to formalize the interrelationships among design, process planning and process implementation; procedures for consideration of the real manufacturing conditions. The paper describes the structure of the CAMPP system and shows the mathematical models and methods to formalize the design procedures.

  15. Emergency Management Computer-Aided Trainer (EMCAT)

    NASA Technical Reports Server (NTRS)

    Rodriguez, R. C.; Johnson, R. P.

    1986-01-01

    The Emergency Management Computer-Aided Trainer (EMCAT) developed by Essex Corporation or NASA and the Federal Emergency Management Administration's (FEMA) National Fire Academy (NFA) is described. It is a computer based training system for fire fighting personnel. A prototype EMCAT system was developed by NASA first using video tape images and then video disk images when the technology became available. The EMCAT system is meant to fill the training needs of the fire fighting community with affordable state-of-the-art technologies. An automated real time simulation of the fire situation was needed to replace the outdated manual training methods currently being used. In order to be successful, this simulator had to provide realism, be user friendly, be affordable, and support multiple scenarios. The EMCAT system meets these requirements and therefore represents an innovative training tool, not only for the fire fighting community, but also for the needs of other disciplines.

  16. An Expert Assistant for Computer Aided Parallelization

    NASA Technical Reports Server (NTRS)

    Jost, Gabriele; Chun, Robert; Jin, Haoqiang; Labarta, Jesus; Gimenez, Judit

    2004-01-01

    The prototype implementation of an expert system was developed to assist the user in the computer aided parallelization process. The system interfaces to tools for automatic parallelization and performance analysis. By fusing static program structure information and dynamic performance analysis data the expert system can help the user to filter, correlate, and interpret the data gathered by the existing tools. Sections of the code that show poor performance and require further attention are rapidly identified and suggestions for improvements are presented to the user. In this paper we describe the components of the expert system and discuss its interface to the existing tools. We present a case study to demonstrate the successful use in full scale scientific applications.

  17. The Preemptive Stocker Dispatching Rule of Automatic Material Handling System in 300 mm Semiconductor Manufacturing Factories

    NASA Astrophysics Data System (ADS)

    Wang, C. N.; Lin, H. S.; Hsu, H. P.; Wang, Yen-Hui; Chang, Y. P.

    2016-04-01

    The integrated circuit (IC) manufacturing industry is one of the biggest output industries in this century. The 300mm wafer fabs is the major fab size of this industry. The automatic material handling system (AMHS) has become one of the most concerned issues among semiconductor manufacturers. The major lot delivery of 300mm fabs is used overhead hoist transport (OHT). The traffic jams are happened frequently due to the wide variety of products and big amount of OHTs moving in the fabs. The purpose of this study is to enhance the delivery performance of automatic material handling and reduce the delay and waiting time of product transportation for both hot lots and normal lots. Therefore, this study proposes an effective OHT dispatching rule: preemptive stocker dispatching (PSD). Simulation experiments are conducted and one of the best differentiated preemptive rule, differentiated preemptive dispatching (DPD), is used for comparison. Compared with DPD, The results indicated that PSD rule can reduce average variable delivery time of normal lots by 13.15%, decreasing average variable delivery time of hot lots by 17.67%. Thus, the PSD rule can effectively reduce the delivery time and enhance productivity in 300 mm wafer fabs.

  18. CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) Highlights.

    DTIC Science & Technology

    1984-10-01

    AD-Aift 532 CAD/CAN (COMPUTER-AIDED DESIGN /COMPUTER-ADD D7 MANUFACTURING) HIGHLIGHTSMU ARMY INDUSTRIAL BASE ENGINEERING ACTIVITY ROCK ISLAND IL D L...1985 B DISCLAIMER This document presents information for the US Army Materiel Command (AMC) Computer-Alded Design /Computer-Aided Manufacturing...contains summaries of Army Computer-Aided Design (CAD) and . Computer-Aided Manufacturing (CAM) efforts that are either completed or ongoing. The Army CAD

  19. User-Centered Computer Aided Language Learning

    ERIC Educational Resources Information Center

    Zaphiris, Panayiotis, Ed.; Zacharia, Giorgos, Ed.

    2006-01-01

    In the field of computer aided language learning (CALL), there is a need for emphasizing the importance of the user. "User-Centered Computer Aided Language Learning" presents methodologies, strategies, and design approaches for building interfaces for a user-centered CALL environment, creating a deeper understanding of the opportunities and…

  20. Computer Aided Battery Engineering Consortium

    SciTech Connect

    Pesaran, Ahmad

    2016-06-07

    A multi-national lab collaborative team was assembled that includes experts from academia and industry to enhance recently developed Computer-Aided Battery Engineering for Electric Drive Vehicles (CAEBAT)-II battery crush modeling tools and to develop microstructure models for electrode design - both computationally efficient. Task 1. The new Multi-Scale Multi-Domain model framework (GH-MSMD) provides 100x to 1,000x computation speed-up in battery electrochemical/thermal simulation while retaining modularity of particles and electrode-, cell-, and pack-level domains. The increased speed enables direct use of the full model in parameter identification. Task 2. Mechanical-electrochemical-thermal (MECT) models for mechanical abuse simulation were simultaneously coupled, enabling simultaneous modeling of electrochemical reactions during the short circuit, when necessary. The interactions between mechanical failure and battery cell performance were studied, and the flexibility of the model for various batteries structures and loading conditions was improved. Model validation is ongoing to compare with test data from Sandia National Laboratories. The ABDT tool was established in ANSYS. Task 3. Microstructural modeling was conducted to enhance next-generation electrode designs. This 3- year project will validate models for a variety of electrodes, complementing Advanced Battery Research programs. Prototype tools have been developed for electrochemical simulation and geometric reconstruction.

  1. Intelligent computer-aided training authoring environment

    NASA Technical Reports Server (NTRS)

    Way, Robert D.

    1994-01-01

    Although there has been much research into intelligent tutoring systems (ITS), there are few authoring systems available that support ITS metaphors. Instructional developers are generally obliged to use tools designed for creating on-line books. We are currently developing an authoring environment derived from NASA's research on intelligent computer-aided training (ICAT). The ICAT metaphor, currently in use at NASA has proven effective in disciplines from satellite deployment to high school physics. This technique provides a personal trainer (PT) who instructs the student using a simulated work environment (SWE). The PT acts as a tutor, providing individualized instruction and assistance to each student. Teaching in an SWE allows the student to learn tasks by doing them, rather than by reading about them. This authoring environment will expedite ICAT development by providing a tool set that guides the trainer modeling process. Additionally, this environment provides a vehicle for distributing NASA's ICAT technology to the private sector.

  2. Geometric modeling for computer aided design

    NASA Technical Reports Server (NTRS)

    Schwing, James L.

    1992-01-01

    The goal was the design and implementation of software to be used in the conceptual design of aerospace vehicles. Several packages and design studies were completed, including two software tools currently used in the conceptual level design of aerospace vehicles. These tools are the Solid Modeling Aerospace Research Tool (SMART) and the Environment for Software Integration and Execution (EASIE). SMART provides conceptual designers with a rapid prototyping capability and additionally provides initial mass property analysis. EASIE provides a set of interactive utilities that simplify the task of building and executing computer aided design systems consisting of diverse, stand alone analysis codes that result in the streamlining of the exchange of data between programs, reducing errors and improving efficiency.

  3. From Phonomecanocardiography to Phonocardiography computer aided

    NASA Astrophysics Data System (ADS)

    Granados, J.; Tavera, F.; López, G.; Velázquez, J. M.; Hernández, R. T.; López, G. A.

    2017-01-01

    Due to lack of training doctors to identify many of the disorders in the heart by conventional listening, it is necessary to add an objective and methodological analysis to support this technique. In order to obtain information of the performance of the heart to be able to diagnose heart disease through a simple, cost-effective procedure by means of a data acquisition system, we have obtained Phonocardiograms (PCG), which are images of the sounds emitted by the heart. A program of acoustic, visual and artificial vision recognition was elaborated to interpret them. Based on the results of previous research of cardiologists a code of interpretation of PCG and associated diseases was elaborated. Also a site, within the university campus, of experimental sampling of cardiac data was created. Phonocardiography computer-aided is a viable and low cost procedure which provides additional medical information to make a diagnosis of complex heart diseases. We show some previous results.

  4. Computer-aided design of LSI topology

    NASA Astrophysics Data System (ADS)

    Seliutin, V. A.

    The problems and methods of the computer-aided design of the topology of LSI circuits and computer-aided manufacture of LSI templates are reviewed. Topics discussed include algorithms for the layout of cells and circuit units, algorithms for tracing connections, the design of the topology of matrix LSI, and the topology of functional LSI circuit units based on MIS structures. The discussion also covers the design of the layout of LSI circuits with single-layer commutation, application examples, and the main trends in the computer-aided design of LSI circuits.

  5. Decentralized Optimal Dispatch of Photovoltaic Inverters in Residential Distribution Systems

    SciTech Connect

    Dall'Anese, Emiliano; Dhople, Sairaj V.; Johnson, Brian B.; Giannakis, Georgios B.

    2015-10-05

    Summary form only given. Decentralized methods for computing optimal real and reactive power setpoints for residential photovoltaic (PV) inverters are developed in this paper. It is known that conventional PV inverter controllers, which are designed to extract maximum power at unity power factor, cannot address secondary performance objectives such as voltage regulation and network loss minimization. Optimal power flow techniques can be utilized to select which inverters will provide ancillary services, and to compute their optimal real and reactive power setpoints according to well-defined performance criteria and economic objectives. Leveraging advances in sparsity-promoting regularization techniques and semidefinite relaxation, this paper shows how such problems can be solved with reduced computational burden and optimality guarantees. To enable large-scale implementation, a novel algorithmic framework is introduced - based on the so-called alternating direction method of multipliers - by which optimal power flow-type problems in this setting can be systematically decomposed into sub-problems that can be solved in a decentralized fashion by the utility and customer-owned PV systems with limited exchanges of information. Since the computational burden is shared among multiple devices and the requirement of all-to-all communication can be circumvented, the proposed optimization approach scales favorably to large distribution networks.

  6. An Elective Course on Computer-Aided Process Design.

    ERIC Educational Resources Information Center

    Sommerfeld, Jude T.

    1979-01-01

    Describes an undergraduate chemical engineering course which has been offered at the Georgia Institute of Technology. The objectives, structure, instructional materials and content of this course, which emphasizes the structure and usage of computer-aided design systems, are also included. (HM)

  7. Computer-Aided Instruction for Adult Professionals: A Research Report.

    ERIC Educational Resources Information Center

    Shaw, Doris Smith

    1992-01-01

    Discusses computer-aided instruction (CAI) for adult learners and describes research conducted at the U.S. Army Construction Engineering Research Laboratory to study the impact of CAI on design professionals, i.e., architects and engineers. Attitudes of adult professionals are examined, and design requirements for a CAI system for professionals…

  8. The Journal of Computer- Aided Molecular Design: a bibliometric note

    NASA Astrophysics Data System (ADS)

    Willett, Peter

    2012-01-01

    Summarizes the articles in, and the citations to, volumes 2-24 of the Journal of Computer- Aided Molecular Design. The citations to the journal come from almost 2000 different sources that span a very wide range of academic subjects, with the most heavily cited articles being descriptions of software systems and of computational methods.

  9. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    PubMed

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  10. Intelligent computer-aided training and tutoring

    NASA Technical Reports Server (NTRS)

    Loftin, R. Bowen; Savely, Robert T.

    1991-01-01

    Specific autonomous training systems based on artificial intelligence technology for use by NASA astronauts, flight controllers, and ground-based support personnel that demonstrate an alternative to current training systems are described. In addition to these specific systems, the evolution of a general architecture for autonomous intelligent training systems that integrates many of the features of traditional training programs with artificial intelligence techniques is presented. These Intelligent Computer-Aided Training (ICAT) systems would provide, for the trainee, much of the same experience that could be gained from the best on-the-job training. By integrating domain expertise with a knowledge of appropriate training methods, an ICAT session should duplicate, as closely as possible, the trainee undergoing on-the-job training in the task environment, benefitting from the full attention of a task expert who is also an expert trainer. Thus, the philosophy of the ICAT system is to emulate the behavior of an experienced individual devoting his full time and attention to the training of a novice - proposing challenging training scenarios, monitoring and evaluating the actions of the trainee, providing meaningful comments in response to trainee errors, responding to trainee requests for information, giving hints (if appropriate), and remembering the strengths and weaknesses displayed by the trainee so that appropriate future exercises can be designed.

  11. Coordination of Economic Load Dispatch and Load Frequency Control for Interconnected Power System

    NASA Astrophysics Data System (ADS)

    Shankar, R.; Chatterjee, K.; Chatterjee, T. K.

    2015-03-01

    This paper deals with the coordination of economic load dispatch and load frequency control concepts of the interconnected power system. The total change in the particular control area is shared by each unit according to their participation factor obtained from the calculation of the economic load dispatch. In this work, two control areas are considered, the first control area contains the combination of hydro, thermal and gas generating unit and in the second control area, it contains the combination of the thermal and hydro generating units. Integral controller is used for secondary controller for load frequency control mechanism. A digital simulation is used in conjunction with the genetic algorithm (GA) technique to determine the optimum parameters of the individual gain of integral controller. Three different types of performance indices are considered to measure the appropriateness of the proposed controller. The optimum values of the gains improve the dynamic performance of the controller and reduce the overshoot and maximum frequency deviation and net tie-line power flow deviation error for a particular load change. To show the effectiveness of the proposed controller, simulation result is shown in result and discussion section.

  12. Computer Aided Design: Instructional Manual. The North Dakota High Technology Mobile Laboratory Project.

    ERIC Educational Resources Information Center

    Cheng, Wan-Lee

    This instructional manual contains 12 learning activity packets for use in a workshop in computer-aided design and drafting (CADD). The lessons cover the following topics: introduction to computer graphics and computer-aided design/drafting; coordinate systems; advance space graphics hardware configuration and basic features of the IBM PC…

  13. The Analytic Process Model for System Design and Measurement: A computer-Aided Tool for Analyzing Training Systems and other Human-Machine Systems

    DTIC Science & Technology

    1985-02-01

    performance measurement; effective- ness measurement; system populations; Bradley Infantry . Fighting Vehicle; BIFV; Analytic Process Model; APM...process model (APM) was developed from earlier models, applied in sample fashions to an existing system (the Bradley Infantry Fighting Vehicle) and...liradley Infantry Fighting Vehicle (Carrier Team Subsystem) 11 6. Example of a System Hierarchical Structure 14 7. Guidelines for Identifying

  14. Modeling, control, and dispatch of photovoltaic-based power distribution systems

    NASA Astrophysics Data System (ADS)

    Carrasco, Miguel

    Small-scale generators, also called distributed generators (DGs), are primed to play a central role in future distribution systems. If properly integrated, DGs present two main advantages: (i) they help decongest existing transmission grids; and (ii) CO2 emissions are reduced since most DGs are based on renewables like wind and solar. Their integration into distribution systems is one of the main challenges the power industry will be facing in the coming years. Photovoltaic (PV) power generation represents a key technology for realizing the DG concept. In this dissertation, technical solutions are developed that enable an increased penetration of PV systems, while improving the efficiency, reliability, and power quality of power distribution grids. The presented research spans from PV array modeling, parameter identification and estimation methods, through advanced control strategies for the power electronic interfaces, to system--level optimal dispatch strategies. Simulation-based and experimental validation results show the performance of the proposed techniques.

  15. Advances in computer-aided design and computer-aided manufacture technology.

    PubMed

    Calamia, J R

    1994-01-01

    Although the development of computer-aided design (CAD) and computer-aided manufacture (CAM) technology and the benefits of increased productivity became obvious in the automobile and aerospace industries in the 1970s, investigations of this technology's application in the field of dentistry did not begin until the 1980s. Only now are we beginning to see the fruits of this work with the commercial availability of some systems; the potential for this technology seems boundless. This article reviews the recent literature with emphasis on the period from June 1992 to May 1993. This review should familiarize the reader with some of the latest developments in this technology, including a brief description of some systems currently available and the clinical and economical rationale for their acceptance into the dental mainstream. This article concentrates on a particular system, the Cerec (Siemens/Pelton and Crane, Charlotte, NC) system, for three reasons: first, this system has been available since 1985 and, as a result, has a track record of almost 7 years of data. Most of the data have just recently been released and consequently, much of this year's literature on CAD-CAM is monopolized by studies using this system. Second, this system was developed as a mobile, affordable, direct chairside CAD-CAM restorative method. As such, it is of special interest to the dentist who will offer this new technology directly to the patient, providing a one-visit restoration. Third, the author is currently engaged in research using this particular system and has a working knowledge of this system's capabilities.

  16. Computer aids for integrated circuit design at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Brown, G. W.

    A general framework for a hierarchical computer-aided design (CAD) system for VLSI design is described. The system supports both functional and physical design in the area of initial design specification, system synthesis, simulation, mask layout, verification, and documentation. The system is being implemented in phases within a user environment on a DECsystem 20-VAX 11/780 computer network. It supports evolutionary changes as new technologies, design strategies, and application programs are developed.

  17. Hybrid Geo-Energy Systems for Energy Storage and Dispatchable Renewable and Low-Carbon Electricity

    NASA Astrophysics Data System (ADS)

    Buscheck, Thomas; Bielicki, Jeffrey; Ogland-Hand, Jonathan; Hao, Yue; Sun, Yunwei; Randolph, Jimmy; Saar, Martin

    2015-04-01

    Three primary challenges for energy systems are to (1) reduce the amount of carbon dioxide (CO2) being emitted to the atmosphere, (2) increase the penetration of renewable energy technologies, and (3) reduce the water intensity of energy production. Integrating variable renewable energy sources (wind, sunlight) into electric grids requires advances in energy storage approaches, which are currently expensive, and tend to have limited capacity and/or geographic deployment potential. Our approach uses CO2, that would otherwise be emitted to the atmosphere, to generate electricity from geothermal resources, to store excess energy from variable (wind, solar photovoltaic) and thermal (nuclear, fossil, concentrated solar power) sources, and to thus enable increased penetration of renewable energy technologies. We take advantage of the enormous fluid and thermal storage capacity of the subsurface to harvest, store, and dispatch energy. Our approach uses permeable geologic formations that are vertically bounded by impermeable layers to constrain pressure and the migration of buoyant CO2 and heated brine. Supercritical CO2 captured from fossil power plants is injected into these formations as a cushion gas to store pressure (bulk energy), provide an heat efficient extraction fluid for efficient power conversion in Brayton Cycle turbines, and generate artesian flow of brine -- which can be used to cool power plants and/or pre-heated (thermal storage) prior to re-injection. Concentric rings of injection and production wells create a hydraulic divide to store pressure, CO2, and thermal energy. The system is pressurized and/or heated when power supply exceeds demand and depressurized when demand exceeds supply. Time-shifting the parasitic loads from pressurizing and injecting brine and CO2 provides bulk energy storage over days to months, whereas time-shifting thermal-energy supply provides dispatchable power and addresses seasonal mismatches between supply and demand. These

  18. Computer aided diagnosis of diabetic peripheral neuropathy

    NASA Astrophysics Data System (ADS)

    Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang

    2014-03-01

    Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.

  19. Computer-aided control in nonround process

    NASA Astrophysics Data System (ADS)

    Fu, Guangjie; Huang, Shenghua

    1995-11-01

    Currently, un-round process (such as piston in internal-combustion engine etc.) is mainly realized by hard contact turning and ellipse milling. This paper introduces the computer-aided control in non-round process, using a high speed voice coil motor which can move to and fro in straight line to drive the cutting tool directly and so as to realize the un-round process under the control of computer. The precision can reach 1 micrometer. It exemplifies the process on convex varying elliptical piston. The best process curve is deduced. Double-CPUs are adopted to realize high speed detection and curve imitation in on-line process. IGBT is selected to drive the motor, optics grid decoder with the resolution of 0.25 micrometer for position detection. The self-adaptive control and feed forward control of sliding model on varying structure assures the request on system's dynamic response and stability. The simulation results reach the expected goal of system design.

  20. Geometric modeling for computer aided design

    NASA Technical Reports Server (NTRS)

    Schwing, James L.; Olariu, Stephen

    1995-01-01

    The primary goal of this grant has been the design and implementation of software to be used in the conceptual design of aerospace vehicles particularly focused on the elements of geometric design, graphical user interfaces, and the interaction of the multitude of software typically used in this engineering environment. This has resulted in the development of several analysis packages and design studies. These include two major software systems currently used in the conceptual level design of aerospace vehicles. These tools are SMART, the Solid Modeling Aerospace Research Tool, and EASIE, the Environment for Software Integration and Execution. Additional software tools were designed and implemented to address the needs of the engineer working in the conceptual design environment. SMART provides conceptual designers with a rapid prototyping capability and several engineering analysis capabilities. In addition, SMART has a carefully engineered user interface that makes it easy to learn and use. Finally, a number of specialty characteristics have been built into SMART which allow it to be used efficiently as a front end geometry processor for other analysis packages. EASIE provides a set of interactive utilities that simplify the task of building and executing computer aided design systems consisting of diverse, stand-alone, analysis codes. Resulting in a streamlining of the exchange of data between programs reducing errors and improving the efficiency. EASIE provides both a methodology and a collection of software tools to ease the task of coordinating engineering design and analysis codes.

  1. Accuracy of emergency medical dispatchers' subjective ability to identify when higher dispatch levels are warranted over a Medical Priority Dispatch System automated protocol's recommended coding based on paramedic outcome data

    PubMed Central

    Clawson, Jeff; Olola, Christopher H O; Heward, Andy; Scott, Greg; Patterson, Brett

    2007-01-01

    Objectives To establish the accuracy of the emergency medical dispatcher's (EMD's) decisions to override the automated Medical Priority Dispatch System (MPDS) logic‐based response code recommendations based on at‐scene paramedic‐applied transport acuity determinations (blue‐in) and cardiac arrest (CA) findings. Methods A retrospective study of a 1 year dataset from the London Ambulance Service (LAS) National Health Service (NHS) Trust was undertaken. We compared all LAS “bluing in” frequency (BIQ) and cardiac arrest quotient (CAQ) outcomes of the incidents automatically recommended and accepted as CHARLIE‐level codes, to those receiving EMD DELTA‐overrides from the auto‐recommended CHARLIE‐level. We also compared the recommended DELTA‐level outcomes to those in the higher ECHO‐override cases. Results There was no significant association between outcome (CA/Blue‐in) and the determinant codes (DELTA‐override and CHARLIE‐level) for both CA (odds ratio (OR) 0, 95% confidence interval (CI) 0 to 41.14; p = 1.000) and Blue‐in categories (OR 0.89, 95% CI 0.34 to 2.33; p = 1.000). Similar patterns were observed between outcome and all DELTA‐level and ECHO‐override codes for both CA (OR 0, 95% CI 0 to 70.05; p = 1.000) and Blue‐in categories (OR 1.17, 95% CI 0 to 7.12; p = 0.597). Conclusion This study contradicts the belief that EMDs can accurately perceive when a patient or situation requires more resources than the MPDS's structured interrogation process logically indicates. This further strengthens the concept that automated, protocol‐based call taking is more accurate and consistent than the subjective, anecdotal or experience‐based determinations made by individual EMDs. PMID:17652678

  2. Engineering Technology Programs Courses Guide for Computer Aided Design and Computer Aided Manufacturing.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Div. of Vocational Education.

    This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…

  3. Radiological technologists' performance for the detection of malignant microcalcifications in digital mammograms without and with a computer-aided detection system.

    PubMed

    Tanaka, Rie; Takamori, Miho; Uchiyama, Yoshikazu; Shiraishi, Junji

    2015-04-01

    The aim of this study was to investigate the diagnostic performance of radiological technologists (RTs) in the detection of malignant microcalcifications and to evaluate how much computer-aided detection (CADe) improved their performances compared with those by expert breast radiologists (BRs). Six board-certified breast RTs and four board-certified BRs participated in a free-response receiver operating characteristic observer study. The dataset consisted of 75 cases (25 malignant, 25 benign, and 25 normal cases) of digital mammograms, selected from the digital database for screening mammography provided by the University of South Florida. Average figure of merit (FOM) of the RTs' performances was statistically analyzed using jack-knife free-response receiver operating characteristic and compared with that of expert BRs. The detection performance of RTs was significantly improved by using CADe; average sensitivity was increased from 46.7% to 56.7%, with a decrease in the average number of false positives per case from 0.19 to 0.13. Detection accuracy of an average FOM was improved from 0.680 to 0.816 ([Formula: see text]) and the difference in FOMs between RTs and radiologists failed to reach statistical significance. RTs' performances for the identification of malignant microcalcifications on digital mammography were sufficiently high and comparable to those of radiologists by using CADe.

  4. Detailed Analysis of Prehospital Interventions in Medical Priority Dispatch System Determinants

    PubMed Central

    Sporer, Karl A.; Johnson, Nicholas J.

    2011-01-01

    Background: Medical Priority Dispatch System (MPDS) is a type of Emergency Medical Dispatch (EMD) system used to prioritize 9-1-1 calls and optimize resource allocation. Dispatchers use a series of scripted questions to assign determinants to calls based on chief complaint and acuity. Objective: We analyzed the prehospital interventions performed on patients with MPDS determinants for breathing problems, chest pain, unknown problem (man down), seizures, fainting (unconscious) and falls for transport status and interventions. Methods: We matched all prehospital patients in complaint-based categories for breathing problems, chest pain, unknown problem (man down), seizures, fainting (unconscious) and falls from January 1, 2004, to December 31, 2006, with their prehospital record. Calls were queried for the following prehospital interventions: Basic Life Support care only, intravenous line placement only, medication given, procedures or non-transport. We defined Advanced Life Support (ALS) interventions as the administration of a medication or a procedure. Results: Of the 77,394 MPDS calls during this period, 31,318 (40%) patients met inclusion criteria. Breathing problems made up 12.2%, chest pain 6%, unknown problem 1.4%, seizures 3%, falls 9% and unconscious/fainting 9% of the total number of MPDS calls. Patients with breathing problem had a low rate of procedures (0.7%) and cardiac arrest medications (1.6%) with 38% receiving some medication. Chest pain patients had a similar distribution; procedures (0.5%), cardiac arrest medication (1.5%) and any medication (64%). Unknown problem: procedures (1%), cardiac arrest medication (1.3%), any medication (18%). Patients with Seizures had a low rate of procedures (1.1%) and cardiac arrest medications (0.6%) with 20% receiving some medication. Fall patients had a lower rate of severe illness with more medication, mostly morphine: procedures (0.2%), cardiac arrest medication (0.2%), all medications (28%). Unconscious

  5. Computer-Aided Video Differential Planimetry

    NASA Astrophysics Data System (ADS)

    Tobin, Michael; Djoleto, Ben D.

    1984-08-01

    THE VIDEO DIFFERENTIAL PLANIMETER (VDP)1 is a re-mote sensing instrument that can measure minute changes in the area of any object seen by an optical scanning system. The composite video waveforms obtained by scanning the object against a contrasting back-ground are amplified and shaped to yield a sequence of constant amplitude pulses whose polarity distinguishes the studied area from its background and whose varying widths reflect the dynamics of the viewed object. These pulses are passed through a relatively long time-constant capacitor-resistor circuit and are then fed into an integrator. The net integration voltage resulting from the most recent sequence of object-background time pulses is recorded and the integrator is returned to zero at the end of each video frame. If the object's area remains constant throughout the following frame, the integrator's summation will also remain constant. However, if the object's area varies, the positive and negative time pulses entering the integrator will change, and the integrator's summation will vary proportionately. The addition of a computer interface and a video recorder enhances the versatility and the resolving power of the VDP by permitting the repeated study and analysis of selected portions of the recorded data, thereby uncovering the major sources of the object's dynamics. Among the medical and biological procedures for which COMPUTER-AIDED VIDEO DIFFERENTIAL PLANIMETRY is suitable are Ophthalmoscopy, Endoscopy, Microscopy, Plethysmography, etc. A recent research study in Ophthalmoscopy2 will be cited to suggest a useful application of Video Differential Planimetry.

  6. Computer Aided Drug Design: Success and Limitations.

    PubMed

    Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho

    2016-01-01

    Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.

  7. Photogrammetry and computer-aided piping design

    SciTech Connect

    Keneflick, J.F.; Chirillo, R.D.

    1985-02-18

    Three-dimensional measurements taken from photographs of a plant model can be digitized and linked with computer-aided piping design. This can short-cut the design and construction of new plants and expedite repair and retrofitting projects. Some designers bridge the gap between model and computer by digitizing from orthographic prints obtained via orthography or the laser scanning of model sections. Such valve or fitting then processed is described in this paper. The marriage of photogrammetry and computer-aided piping design can economically produce such numerical drawings.

  8. A computer-aided regulator design.

    NASA Technical Reports Server (NTRS)

    Karmarkar, J. S.; Siljak, D. D.

    1972-01-01

    A unified computer-aided method for the design of linear and nonlinear regulators is discussed. The general mathematical programming approach considered involves the determination of a vector that solves the problem of minimizing the objective function subject to constraints. Classical design problems stated are related to stability design, dominant mode design, and comprehensive design. A computer algorithm is also developed.

  9. Computer-Aided Corrosion Program Management

    NASA Technical Reports Server (NTRS)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  10. New Paradigms for Computer Aids to Invention.

    ERIC Educational Resources Information Center

    Langston, M. Diane

    Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…

  11. Computer-Aided Medical Diagnosis. Literature Review

    DTIC Science & Technology

    1978-12-15

    BOUCKAERT, A., Computer-aided diagnosis of goitres in a cancer department, Int. J. Bio-’Med. Comput., 3 (1972) p. 3. BOYLE, J. A., GREIG, W. R., FRANKLIN, D...toxic goitre , Q. J. Med., 35 (1966) p. 565. Bricetti, A. B. and Bleich, H. L., A computer program that evaluates patients with hypercalcemia, J

  12. Computer-Aided Instruction and Communication Skills.

    ERIC Educational Resources Information Center

    Euler, Dieter

    1990-01-01

    Investigates effect of computer-aided instruction (CAI) on acquisition of communication skills. Sketches a tutorial of the basic communication structure. Recommends confining CAI to cognitive learning because CAI cannot advance communication skills. Maintains that integrating CAI in social arrangements will allow the computer to remain an…

  13. Computer Aided Learning of Mathematics: Software Evaluation

    ERIC Educational Resources Information Center

    Yushau, B.; Bokhari, M. A.; Wessels, D. C. J.

    2004-01-01

    Computer Aided Learning of Mathematics (CALM) has been in use for some time in the Prep-Year Mathematics Program at King Fahd University of Petroleum & Minerals. Different kinds of software (both locally designed and imported) have been used in the quest of optimizing the recitation/problem session hour of the mathematics classes. This paper…

  14. Computer Aided Grid Interface: An Interactive CFD Pre-Processor

    NASA Technical Reports Server (NTRS)

    Soni, Bharat K.

    1996-01-01

    NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the Computer Aided Grid Interface system (CAGI). The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and / or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.

  15. Computer Aided Grid Interface: An Interactive CFD Pre-Processor

    NASA Technical Reports Server (NTRS)

    Soni, Bharat K.

    1997-01-01

    NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the CAGI: Computer Aided Grid Interface system. The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and/or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.

  16. Computer aided coordination of line protection schemes IEEE committee report

    SciTech Connect

    Postforoosh, J.M.; Akamine, J.; Banerjee, H.N.; Cornelison, J.R.; Enns, M.K.; Grier, S.E.; Hass, R.W.; Hasenwinkle, I.O.; Johnson, R.W.; Mozina, C.J.; Ramaswami, R.; Smith, H.S.; Taylor, R.P.; Turley, J.R.; Zipp, J.A.

    1991-04-01

    IEEE PSRC working group on Computer Aided Coordination of Line Protection Schemes was established in 1985 to investigate the application of computers to the task of setting and verifying the setting of line protective devices. This report provides the findings of the working group regarding functional requirements of the data base, software, and hardware for this system as well as the methods of presenting the results to the protection engineer.

  17. Computer-aided design and computer science technology

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Voigt, S. J.

    1976-01-01

    A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.

  18. CADEE: Computer-Aided Directed Evolution of Enzymes.

    PubMed

    Amrein, Beat Anton; Steffen-Munsberg, Fabian; Szeler, Ireneusz; Purg, Miha; Kulkarni, Yashraj; Kamerlin, Shina Caroline Lynn

    2017-01-01

    The tremendous interest in enzymes as biocatalysts has led to extensive work in enzyme engineering, as well as associated methodology development. Here, a new framework for computer-aided directed evolution of enzymes (CADEE) is presented which allows a drastic reduction in the time necessary to prepare and analyze in silico semi-automated directed evolution of enzymes. A pedagogical example of the application of CADEE to a real biological system is also presented in order to illustrate the CADEE workflow.

  19. CADEE: Computer-Aided Directed Evolution of Enzymes

    PubMed Central

    Amrein, Beat Anton; Steffen-Munsberg, Fabian; Szeler, Ireneusz; Purg, Miha; Kamerlin, Shina Caroline Lynn

    2017-01-01

    The tremendous interest in enzymes as biocatalysts has led to extensive work in enzyme engineering, as well as associated methodology development. Here, a new framework for computer-aided directed evolution of enzymes (CADEE) is presented which allows a drastic reduction in the time necessary to prepare and analyze in silico semi-automated directed evolution of enzymes. A pedagogical example of the application of CADEE to a real biological system is also presented in order to illustrate the CADEE workflow. PMID:28250941

  20. Application of Particle Swarm Optimization in Computer Aided Setup Planning

    NASA Astrophysics Data System (ADS)

    Kafashi, Sajad; Shakeri, Mohsen; Abedini, Vahid

    2011-01-01

    New researches are trying to integrate computer aided design (CAD) and computer aided manufacturing (CAM) environments. The role of process planning is to convert the design specification into manufacturing instructions. Setup planning has a basic role in computer aided process planning (CAPP) and significantly affects the overall cost and quality of machined part. This research focuses on the development for automatic generation of setups and finding the best setup plan in feasible condition. In order to computerize the setup planning process, three major steps are performed in the proposed system: a) Extraction of machining data of the part. b) Analyzing and generation of all possible setups c) Optimization to reach the best setup plan based on cost functions. Considering workshop resources such as machine tool, cutter and fixture, all feasible setups could be generated. Then the problem is adopted with technological constraints such as TAD (tool approach direction), tolerance relationship and feature precedence relationship to have a completely real and practical approach. The optimal setup plan is the result of applying the PSO (particle swarm optimization) algorithm into the system using cost functions. A real sample part is illustrated to demonstrate the performance and productivity of the system.

  1. Computer-aided dental prostheses construction using reverse engineering.

    PubMed

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  2. Microstereolithography-based computer-aided manufacturing for tissue engineering.

    PubMed

    Cho, Dong-Woo; Kang, Hyun-Wook

    2012-01-01

    Various solid freeform fabrication technologies have been introduced for constructing three-dimensional (3-D) freeform structures. Of these, microstereolithography (MSTL) technology performs the best in 3-D space because it not only has high resolution, but also fast fabrication speed. Using this technology, 3-D structures with mesoscale size and microscale resolution are achievable. Many researchers have been trying to apply this technology to tissue engineering to construct medically applicable scaffolds, which require a 3-D shape that fits a defect with a mesoscale size and microscale inner architecture for efficient regeneration of artificial tissue. This chapter introduces the principles of MSTL technology and representative systems. It includes fabrication and computer-aided design/computer-aided manufacturing (CAD/CAM) processes to show the automation process by which measurements from medical images are used to fabricate the required 3-D shape. Then, various tissue engineering applications based on MSTL are summarized.

  3. Method of computer-aided measurement in a shooting range

    NASA Astrophysics Data System (ADS)

    Liu, Chanlao; Zhang, Yun; Xiong, Rensheng; Sun, Yishang

    2000-10-01

    In the view of the blindness of photoelectric measurement scheme argument and the danger of live shell measurement in shooting range, this paper provided a computer aided measurement method guiding the measurement scheme argument and equipment researching and producing and driving the measurement process visiblization and standardization. The computer aided measurement in shooting range can be divided into the mathematical simulation of targets moving, the mathematical simulation of measurement method, the mathematical simulation of photoelectric system, the animated displaying of measurement process, and so on. By adding random jamming, Gaussian white noise and so on, the live measurement environment and condition was built. By using mathematical discretization, the time series pictures was obtained. By controlling the time changing and time unifying of several equipment, the animated displaying of measurement process was built. The programming language was MATLAB. The method was proved through simulating the intersection measurement trajectory of antiaircraft gun's shell successfully.

  4. Discriminating coastal rangeland production and improvements with computer aided techniques

    NASA Technical Reports Server (NTRS)

    Reeves, C. A.; Faulkner, D. P.

    1975-01-01

    The feasibility and utility of using satellite data and computer-aided remote sensing analysis techniques to conduct range inventories were tested. This pilot study was focused over a 250,000 acre site in Galveston and Brazoria Counties along the Texas Gulf Coast. Rectified enlarged aircraft color infrared photographs of this site were used as the ground truth base. The different land categories were identified, delineated, and measured. Multispectral scanner (MSS) bulk data from LANDSAT-1 was received and analyzed with the Image 100 pattern recognition system. Features of interest were delineated on the image console giving the number of picture elements classified; the picture elements were converted to acreages and the accuracy of the technique was evaluated by comparison with data base results for three test sites. The accuracies for computer aided classification of coastal marshes ranged from 89% to 96%.

  5. Letter regarding 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics' by Patrizi et al. and research reproducibility.

    PubMed

    2017-04-01

    The reporting of research in a manner that allows reproduction in subsequent investigations is important for scientific progress. Several details of the recent study by Patrizi et al., 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics', are absent from the published manuscript and make reproduction of findings impossible. As new and complex technologies with great promise for ergonomics develop, new but surmountable challenges for reporting investigations using these technologies in a reproducible manner arise. Practitioner Summary: As with traditional methods, scientific reporting of new and complex ergonomics technologies should be performed in a manner that allows reproduction in subsequent investigations and supports scientific advancement.

  6. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    SciTech Connect

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  7. Teleradiology network system and computer-aided diagnosis workstation using the web medical image conference system with a new information security solution

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2011-03-01

    We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of RAID. With RAID technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. We can safely share the screen of workstation to which the medical image of Data Center is displayed from two or more web conference terminals at the same time. Moreover, Real time biometric face authentication system is connected with Data Center. Real time biometric face authentication system analyzes the feature of the face image of which it takes a picture in 20 seconds with the camera and defends the safety of the medical information. We propose a new information transmission method and a new information storage method with a new information security solution.

  8. Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature

    PubMed Central

    Baroudi, Kusai; Ibraheem, Shukran Nasser

    2015-01-01

    Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082

  9. Computer aided nonlinear electrical networks analysis

    NASA Technical Reports Server (NTRS)

    Slapnicar, P.

    1977-01-01

    Techniques used in simulating an electrical circuit with nonlinear elements for use in computer-aided circuit analysis programs are described. Elements of the circuit include capacitors, resistors, inductors, transistors, diodes, and voltage and current sources (constant or time varying). Simulation features are discussed for dc, ac, and/or transient circuit analysis. Calculations are based on the model approach of formulating the circuit equations. A particular solution of transient analysis for nonlinear storage elements is described.

  10. Continuing education through computer-aided instruction

    SciTech Connect

    Fox, J.

    1981-01-01

    Computer-aided and managed instruction has been incorporated into the continuing education program in the Electronics Division of the Los Alamos National Laboratory. Two Control Data Corporation PLATO terminals have been installed in the learning center, and have been providing individualized instruction to the employees for approximately 2 years. Reactions from users and total usage figures indicate that there are unique advantages to computer-aided instruction. User interaction with a computer assures individual response from a student. The learner must be actively involved in the course and cannot passively allow content to flow by. Complex simulations can be programed and used in the learning process; thus, expensive equipment can be spared the wear and tear attributed to learners. The breadth of course topics included in the on-line library assures that PLATO has a continuing education offering for most employees. New lessons appear on line at the rate of three or four per week; PLATO cost effectiveness is thus certified. Comparisons of courses taken on the terminal to the same or similar courses offered elsewhere indicate that PLATO is advantageous. Computer-aided instruction is available when the learner is ready for initial instruction and later for reviews. At Los Alamos, the demand for PLATO service is growing. The Laboratory will have eight terminals installed and operating by April 1981. 8 tables.

  11. Computer-aided periodontal disease diagnosis using computer vision.

    PubMed

    Juan, M C; Alcañiz, M; Monserrat, C; Grau, V; Knoll, C

    1999-01-01

    Periodontal diseases are the major cause of tooth loss. The study of the evolution of these diseases is crucial to achieve adequate planning and treatment. Depth probing is essential to know the periodontal disease stage. In this paper we present a new system for Computer-Aided Periodontal Disease Diagnosis using computer vision. The system automates the depth probing and incorporates a colour camera fitted together with a plastic probe that automatically and exactly obtains the depth probing measure. The system has been tested by several periodontists and with 125 teeth of different patients. The differences between the values taken by the system and two periodontists have not been significant.

  12. The Computer-Aided Analytic Process Model. Operations Handbook for the APM (Analytic Process Model) Demonstration Package. Appendix

    DTIC Science & Technology

    1986-01-01

    The Analytic Process Model for System Design and Measurement: A Computer-Aided Tool for Analyzing Training Systems and Other Human-Machine Systems. A...separate companion volume--The Computer-Aided Analytic Process Model : Operations Handbook for the APM Demonstration Package is also available under

  13. A Multiobjective Interval Programming Model for Wind-Hydrothermal Power System Dispatching Using 2-Step Optimization Algorithm

    PubMed Central

    Jihong, Qu

    2014-01-01

    Wind-hydrothermal power system dispatching has received intensive attention in recent years because it can help develop various reasonable plans to schedule the power generation efficiency. But future data such as wind power output and power load would not be accurately predicted and the nonlinear nature involved in the complex multiobjective scheduling model; therefore, to achieve accurate solution to such complex problem is a very difficult task. This paper presents an interval programming model with 2-step optimization algorithm to solve multiobjective dispatching. Initially, we represented the future data into interval numbers and simplified the object function to a linear programming problem to search the feasible and preliminary solutions to construct the Pareto set. Then the simulated annealing method was used to search the optimal solution of initial model. Thorough experimental results suggest that the proposed method performed reasonably well in terms of both operating efficiency and precision. PMID:24895663

  14. A multiobjective interval programming model for wind-hydrothermal power system dispatching using 2-step optimization algorithm.

    PubMed

    Ren, Kun; Jihong, Qu

    2014-01-01

    Wind-hydrothermal power system dispatching has received intensive attention in recent years because it can help develop various reasonable plans to schedule the power generation efficiency. But future data such as wind power output and power load would not be accurately predicted and the nonlinear nature involved in the complex multiobjective scheduling model; therefore, to achieve accurate solution to such complex problem is a very difficult task. This paper presents an interval programming model with 2-step optimization algorithm to solve multiobjective dispatching. Initially, we represented the future data into interval numbers and simplified the object function to a linear programming problem to search the feasible and preliminary solutions to construct the Pareto set. Then the simulated annealing method was used to search the optimal solution of initial model. Thorough experimental results suggest that the proposed method performed reasonably well in terms of both operating efficiency and precision.

  15. A new Self-Adaptive disPatching System for local clusters

    NASA Astrophysics Data System (ADS)

    Kan, Bowen; Shi, Jingyan; Lei, Xiaofeng

    2015-12-01

    The scheduler is one of the most important components of a high performance cluster. This paper introduces a self-adaptive dispatching system (SAPS) based on Torque[1] and Maui[2]. It promotes cluster resource utilization and improves the overall speed of tasks. It provides some extra functions for administrators and users. First of all, in order to allow the scheduling of GPUs, a GPU scheduling module based on Torque and Maui has been developed. Second, SAPS analyses the relationship between the number of queueing jobs and the idle job slots, and then tunes the priority of users’ jobs dynamically. This means more jobs run and fewer job slots are idle. Third, integrating with the monitoring function, SAPS excludes nodes in error states as detected by the monitor, and returns them to the cluster after the nodes have recovered. In addition, SAPS provides a series of function modules including a batch monitoring management module, a comprehensive scheduling accounting module and a real-time alarm module. The aim of SAPS is to enhance the reliability and stability of Torque and Maui. Currently, SAPS has been running stably on a local cluster at IHEP (Institute of High Energy Physics, Chinese Academy of Sciences), with more than 12,000 cpu cores and 50,000 jobs running each day. Monitoring has shown that resource utilization has been improved by more than 26%, and the management work for both administrator and users has been reduced greatly.

  16. A computer-aided approach to nonlinear control systhesis

    NASA Technical Reports Server (NTRS)

    Wie, Bong; Anthony, Tobin

    1988-01-01

    The major objective of this project is to develop a computer-aided approach to nonlinear stability analysis and nonlinear control system design. This goal is to be obtained by refining the describing function method as a synthesis tool for nonlinear control design. The interim report outlines the approach by this study to meet these goals including an introduction to the INteractive Controls Analysis (INCA) program which was instrumental in meeting these study objectives. A single-input describing function (SIDF) design methodology was developed in this study; coupled with the software constructed in this study, the results of this project provide a comprehensive tool for design and integration of nonlinear control systems.

  17. Interfacing Computer Aided Parallelization and Performance Analysis

    NASA Technical Reports Server (NTRS)

    Jost, Gabriele; Jin, Haoqiang; Labarta, Jesus; Gimenez, Judit; Biegel, Bryan A. (Technical Monitor)

    2003-01-01

    When porting sequential applications to parallel computer architectures, the program developer will typically go through several cycles of source code optimization and performance analysis. We have started a project to develop an environment where the user can jointly navigate through program structure and performance data information in order to make efficient optimization decisions. In a prototype implementation we have interfaced the CAPO computer aided parallelization tool with the Paraver performance analysis tool. We describe both tools and their interface and give an example for how the interface helps within the program development cycle of a benchmark code.

  18. Removal of Supernumerary Teeth Utilizing a Computer-Aided Design/Computer-Aided Manufacturing Surgical Guide.

    PubMed

    Jo, Chanwoo; Bae, Doohwan; Choi, Byungho; Kim, Jihun

    2016-11-12

    Supernumerary teeth need to be removed because they can cause various complications. Caution is needed because their removal can cause damage to permanent teeth or tooth germs in the local vicinity. Surgical guides have recently been used in maxillofacial surgery. Because surgical guides are designed through preoperative analysis by computer-aided design software and fabricated using a 3-dimensional printer applying computer-aided manufacturing technology, they increase the accuracy and predictability of surgery. This report describes 2 cases of removal of a mesiodens-1 from a child and 1 from an adolescent-using a surgical guide; these would have been difficult to remove with conventional surgical methods.

  19. Computer-Aided Tomographic Analysis of Interstitial Lung Disease (ILD) in Patients with Systemic Sclerosis (SSc). Correlation with Pulmonary Physiologic Tests and Patient-Centred Measures of Perceived Dyspnea and Functional Disability

    PubMed Central

    Salaffi, Fausto; Carotti, Marina; Di Donato, Eleonora; Di Carlo, Marco; Ceccarelli, Luca; Giuseppetti, Gianmarco

    2016-01-01

    Objectives This study was designed (a) to evaluate an improved quantitative lung fibrosis score based on a computer-aided diagnosis (CaM) system in patients with systemic sclerosis (SSc),—related interstitial lung disease (SSc-ILD), (b) to investigate the relationship between physiologic parameters (forced vital capacity [FVC] and single-breath diffusing capacity for carbon monoxide [DLCO]), patient-centred measures of dyspnea and functional disability and CaM and visual reader-based (CoVR) methods, and (c) to identify potential surrogate measures from quantitative and visual HRCT measurement. Methods 126 patients with SSc underwent chest radiography, HRCT and PFTs. The following patient-centred measures were obtained: modified Borg Dyspnea Index (Borg score), VAS for breathing, and Health Assessment Questionnaire-Disability Index (HAQ-DI). HRCT abnormalities were scored according to the conventional visual reader-based score (CoVR) and by a CaM. The relationships among the HRCT scores, physiologic parameters (FVC and DLCO, % predicted) results and patient-centred measures, were calculated using linear regression analysis and Pearson’s correlation. Multivariate regression models were performed to identify the predictor variables on severity of pulmonary fibrosis. Results Subjects with limited cutaneous SSc had lower HAQ-DI scores than subjects with diffuse cutaneous SSc (p <0.001). CaM and CoVR scores were similar in the 2 groups. In univariate analysis, a strong correlation between CaM and CoVR was observed (p <0.0001). In multivariate analysis the CaM and CoVR scores were predicted by DLco, FVC, Borg score and HAQ-DI. Age, sex, disease duration, anti-topoisomerase antibodies and mRSS were not significantly associated with severity of pulmonary fibrosis on CaM- and CoVR methods. Conclusions Although a close correlation between CaM score results and CoVR total score was found, CaM analysis showed a more significant correlation with DLco (more so than the FVC

  20. Retrospective indexing (RI) - A computer-aided indexing technique

    NASA Technical Reports Server (NTRS)

    Buchan, Ronald L.

    1990-01-01

    An account is given of a method for data base-updating designated 'computer-aided indexing' (CAI) which has been very efficiently implemented at NASA's Scientific and Technical Information Facility by means of retrospective indexing. Novel terms added to the NASA Thesaurus will therefore proceed directly into both the NASA-RECON aerospace information system and its portion of the ESA-Information Retrieval Service, giving users full access to material thus indexed. If a given term appears in the title of a record, it is given special weight. An illustrative graphic representation of the CAI search strategy is presented.

  1. WEMAP - A computer aided instructional tool for electromagnetics

    SciTech Connect

    Garg, V.K.; Ware, L.E.; Bogden, F.J.; DelVecchio, R.M.; Ashkin, M.; Woodward, W.S.

    1989-05-01

    The recent advances in computer technology and associated software have introduced new concepts and techniques into the traditional classroom environment of engineering education. WEMAP, an electromagnetic analysis computer code, is a part of a new breed of computer aided engineering tools for teaching electromagnetics to power engineering students. WEMAP is a stand-alone interactive graphics system for electromagnetic analysis, which includes electrostatics, magnetostatics, eddy currents (time harmonic as well as transient), and permanent magnet fields. These capabilities are described in this paper and examples are given to illustrate how this program enhances the classroom presentation of some of the electromagnetic phenomena.

  2. NALDA (Naval Aviation Logistics Data Analysis) CAI (computer aided instruction)

    SciTech Connect

    Handler, B.H. ); France, P.A.; Frey, S.C.; Gaubas, N.F.; Hyland, K.J.; Lindsey, A.M.; Manley, D.O. ); Hunnum, W.H. ); Smith, D.L. )

    1990-07-01

    Data Systems Engineering Organization (DSEO) personnel developed a prototype computer aided instruction CAI system for the Naval Aviation Logistics Data Analysis (NALDA) system. The objective of this project was to provide a CAI prototype that could be used as an enhancement to existing NALDA training. The CAI prototype project was performed in phases. The task undertaken in Phase I was to analyze the problem and the alternative solutions and to develop a set of recommendations on how best to proceed. The findings from Phase I are documented in Recommended CAI Approach for the NALDA System (Duncan et al., 1987). In Phase II, a structured design and specifications were developed, and a prototype CAI system was created. A report, NALDA CAI Prototype: Phase II Final Report, was written to record the findings and results of Phase II. NALDA CAI: Recommendations for an Advanced Instructional Model, is comprised of related papers encompassing research on computer aided instruction CAI, newly developing training technologies, instructional systems development, and an Advanced Instructional Model. These topics were selected because of their relevancy to the CAI needs of NALDA. These papers provide general background information on various aspects of CAI and give a broad overview of new technologies and their impact on the future design and development of training programs. The paper within have been index separately elsewhere.

  3. Industrial Technology Modernization Program. Appendix 1. User Software Documentation. Appendix 2. Program Documentation, Category 2 Project. Computer Aided Processing System (CAPS)

    DTIC Science & Technology

    1987-03-20

    VAX Auto-Insertion Program. . . . . 55 12.6 The VAX Auto-Insertion Program. . . . . . . . 56 12.6.1 Enter Program Manager . . . . . . . . 57 12.6.2 Edit...by identifying which method codes are affected, and which assemblies use those method codes. Additionally, CAPS greatly reduces the risk of human...system manager . The following message should then appear: Password: Now enter you password, also supplied by the system manager . To preserve security

  4. Computer-aided detection system for clustered microcalcifications in digital breast tomosynthesis using joint information from volumetric and planar projection images

    NASA Astrophysics Data System (ADS)

    Samala, Ravi K.; Chan, Heang-Ping; Lu, Yao; Hadjiiski, Lubomir M.; Wei, Jun; Helvie, Mark A.

    2015-11-01

    We propose a novel approach for the detection of microcalcification clusters (MCs) using joint information from digital breast tomosynthesis (DBT) volume and planar projection (PPJ) image. A data set of 307 DBT views was collected with IRB approval using a prototype DBT system. The system acquires 21 projection views (PVs) from a wide tomographic angle of 60° (60°-21PV) at about twice the dose of a digital mammography (DM) system, which allows us the flexibility of simulating other DBT acquisition geometries using a subset of the PVs. In this study, we simulated a 30° DBT geometry using the central 11 PVs (30°-11PV). The narrower tomographic angle is closer to DBT geometries commercially available or under development and the dose is matched approximately to that of a DM. We developed a new joint-CAD system for detection of clustered microcalcifications. The DBT volume was reconstructed with a multiscale bilateral filtering regularized method and a PPJ image was generated from the reconstructed volume. Task-specific detection strategies were designed to combine information from the DBT volume and the PPJ image. The data set was divided into a training set (127 views with MCs) and an independent test set (104 views with MCs and 76 views without MCs). The joint-CAD system outperformed the individual CAD systems for DBT volume or PPJ image alone; the differences in the test performances were statistically significant (p  <  0.05) using JAFROC analysis.

  5. CAGI: Computer Aided Grid Interface. A work in progress

    NASA Technical Reports Server (NTRS)

    Soni, Bharat K.; Yu, Tzu-Yi; Vaughn, David

    1992-01-01

    Progress realized in the development of a Computer Aided Grid Interface (CAGI) software system in integrating CAD/CAM geometric system output and/or Interactive Graphics Exchange Standard (IGES) files, geometry manipulations associated with grid generation, and robust grid generation methodologies is presented. CAGI is being developed in a modular fashion and will offer fast, efficient and economical response to geometry/grid preparation, allowing the ability to upgrade basic geometry in a step-by-step fashion interactively and under permanent visual control along with minimizing the differences between the actual hardware surface descriptions and corresponding numerical analog. The computer code GENIE is used as a basis. The Non-Uniform Rational B-Splines (NURBS) representation of sculptured surfaces is utilized for surface grid redistribution. The computer aided analysis system, PATRAN, is adapted as a CAD/CAM system. The progress realized in NURBS surface grid generation, the development of IGES transformer, and geometry adaption using PATRAN will be presented along with their applicability to grid generation associated with rocket propulsion applications.

  6. Evaluation of Computer-Aided System Design Tools for SDI (Strategic Defense Initiative) Battle Management/C3 (Command, Control and Communications) Architecture Development

    DTIC Science & Technology

    1987-10-01

    Ft. Meade, MD 20755-6000 Lee Cooper 1 copy Advanced Technology 2121 Crystal Drive, Suite 200 Arlington, VA 22202 Larry Cox I copy TRW 1950 Sunwest...Richmond Street Providence, RI 02903 " - Mr. Larry Christina, Jr. 1 copy Technology Branch, CSSD-H-SBY Battle Management Division U.S. Army Strategic...copy ’_ Advanced System Architectures Johnson House 73-79 Park Street GU 15 3PE, United Kingdom s. - .%° N. % S CSED Review Panel Dr. Dan Alpert

  7. A Computer Aided Design for the Generation of Test Transactions and Test Databases and for the Benchmarking of Parallel, Multiple Backend Database Systems.

    DTIC Science & Technology

    1986-06-01

    performance claims, a benchmarking methodolgy has been formulated in the Naval Postgraduate Thesis. "A Performance Measurement Methodology for Software...is a research effort conducted jointly by the Naval Postgraduate School and Ohio State University with the sponsorship of the STARS foundation. The...systems. To verify the aforementioned capacity growth and performance claims, a benchmarking methodology has been formulated in the Naval Postgraduate

  8. Rapid Geometry Creation for Computer-Aided Engineering Parametric Analyses: A Case Study Using ComGeom2 for Launch Abort System Design

    NASA Technical Reports Server (NTRS)

    Hawke, Veronica; Gage, Peter; Manning, Ted

    2007-01-01

    ComGeom2, a tool developed to generate Common Geometry representation for multidisciplinary analysis, has been used to create a large set of geometries for use in a design study requiring analysis by two computational codes. This paper describes the process used to generate the large number of configurations and suggests ways to further automate the process and make it more efficient for future studies. The design geometry for this study is the launch abort system of the NASA Crew Launch Vehicle.

  9. An online real-time DICOM web-based computer-aided diagnosis system for bone age assessment of children in a PACS environment

    NASA Astrophysics Data System (ADS)

    Ma, Kevin C.; Zhang, Aifeng; Moin, Paymann; Fleshman, Mariam; Vachon, Linda; Liu, Brent; Huang, H. K.

    2009-02-01

    Bone age assessment is a radiological procedure to evaluate a child's bone age based on his or her left-hand x-ray image. The current standard is to match patient's hand with Greulich & Pyle hand atlas, which is outdated by 50 years and only uses subjects from one region and one ethnicity. To improve bone age assessment accuracy for today's children, an automated race- and gender-specific bone age assessment (BAA) system has been developed in IPILab. 1390 normal left-hand x-ray images have been collected at Children's Hospital of Los Angeles (CHLA) to form the digital hand atlas (DHA). DHA includes both male and female children of ages one to eighteen and of four ethnic groups: African American, Asian American, Caucasian, and Hispanic. In order to apply DHA and BAA CAD into a clinical environment, a web-based BAA CAD system and graphical user interface (GUI) has been implemented in Women and Children's Hospital at Los Angeles County (WCH-LAC). A CAD server has been integrated in WCH's PACS environment, and a clinical validation workflow has been designed for radiologists, who compare CAD readings with G&P readings and determine which reading is more suited for a certain case. Readings are logged in database and analyzed to assess BAA CAD performance in a clinical setting. The result is a successful installation of web-based BAA CAD system in a clinical setting.

  10. Computer-Aided Quantification of Interstitial Lung Disease from High Resolution Computed Tomography Images in Systemic Sclerosis: Correlation with Visual Reader-Based Score and Physiologic Tests

    PubMed Central

    Salaffi, Fausto; Carotti, Marina; Bosello, Silvia; Bichisecchi, Elisabetta; Giuseppetti, Gianmarco; Ferraccioli, Gianfranco

    2015-01-01

    Objective. To evaluate the performance of a computerized-aided method (CaM) for quantification of interstitial lung disease (ILD) in patients with systemic sclerosis and to determine its correlation with the conventional visual reader-based score (CoVR) and the pulmonary function tests (PFTs). Methods. Seventy-nine patients were enrolled. All patients underwent chest high resolution computed tomography (HRCT) scored by two radiologists adopting the CoVR. All HRCT images were then analysed by a CaM using a DICOM software. The relationships among the lung segmentation analysis, the readers, and the PFTs results were calculated using linear regression analysis and Pearson's correlation. Receiver operating curve analysis was performed for determination of CaM extent threshold. Results. A strong correlation between CaM and CoVR was observed (P < 0.0001). The CaM showed a significant negative correlation with forced vital capacity (FVC) (P < 0.0001) and the single breath carbon monoxide diffusing capacity of the lung (DLco) (P < 0.0001). A CaM optimal extent threshold of 20% represented the best compromise between sensitivity (75.6%) and specificity (97.4%). Conclusions. CaM quantification of SSc-ILD can be useful in the assessment of extent of lung disease and may provide reliable tool in daily clinical practice and clinical trials. PMID:25629053

  11. In Vitro Comparison of Raypex 6 and Endopilot Using a Novel, Computer-Aided Measurement System, for Determining the Working Length

    PubMed Central

    Christofzik, David; Schwendicke, Falk; Flörke, Christian; Härtl, Alexander; Dörfer, Christof; Größner-Schreiber, Birte

    2015-01-01

    Introduction Experimental evaluation of endometric devices usually relies on visual, subjective detection of the apical constriction to determine the accuracy of measurements. The aim of the present study was to analyze the accuracy of measurements of Raypex 6 and EndoPilot using a novel, objective image-analysis system. Methods Onehundred and twenty teeth were randomized and allocated to three groups: After coronal flaring, either Raypex 6 or EndoPilot were used to determine the endodontic working length during instrumentation using manual files (RPM and EPM group respectively). In addition, EndoPilot was used for continuous, automatic measurement during rotating instrumentation (EPA group). If the working length had been reached according to endometric results, the files were fixed in place. Tooth and file were then embedded and prepared for analysis. Subsequently, the distance between the tip of the file and the apical constriction (DAC) or the apical foramen (DAF) was calculated using trigonometric analysis and the position of the file relative to AC and AF was analyzed. Results Both inter- and intra-examiner-reliability of the trigonometric analysis were nearly perfect (ICC = 0.999, p<0.001). DAC was not significantly different between groups (p>0.05, t-test). DAF was significantly decreased when EPA had been used compared to EPM (p<0.05, Exact-test). EPA resulted in files being positioned beyond AF significantly more often than the other two methods (p<0.01). Conclusions All methods allowed reliable detection of AC. However, EPA significantly increased the risk of overpreparation. Objective, digital assessment based on image analysis was suitable to compare the accuracy of different endometric devices. PMID:26237310

  12. Geometric modeling for computer aided design

    NASA Technical Reports Server (NTRS)

    Schwing, James L.

    1993-01-01

    Over the past several years, it has been the primary goal of this grant to design and implement software to be used in the conceptual design of aerospace vehicles. The work carried out under this grant was performed jointly with members of the Vehicle Analysis Branch (VAB) of NASA LaRC, Computer Sciences Corp., and Vigyan Corp. This has resulted in the development of several packages and design studies. Primary among these are the interactive geometric modeling tool, the Solid Modeling Aerospace Research Tool (smart), and the integration and execution tools provided by the Environment for Application Software Integration and Execution (EASIE). In addition, it is the purpose of the personnel of this grant to provide consultation in the areas of structural design, algorithm development, and software development and implementation, particularly in the areas of computer aided design, geometric surface representation, and parallel algorithms.

  13. Computer-aided tissue engineering: overview, scope and challenges.

    PubMed

    Sun, Wei; Darling, Andrew; Starly, Binil; Nam, Jae

    2004-02-01

    Advances in computer-aided technology and its application with biology, engineering and information science to tissue engineering have evolved a new field of computer-aided tissue engineering (CATE). This emerging field encompasses computer-aided design (CAD), image processing, manufacturing and solid free-form fabrication (SFF) for modelling, designing, simulation and manufacturing of biological tissue and organ substitutes. The present Review describes some salient advances in this field, particularly in computer-aided tissue modeling, computer-aided tissue informatics and computer-aided tissue scaffold design and fabrication. Methodologies of development of CATE modelling from high-resolution non-invasive imaging and image-based three-dimensional reconstruction, and various reconstructive techniques for CAD-based tissue modelling generation will be described. The latest development in SFF to tissue engineering and a framework of bio-blueprint modelling for three-dimensional cell and organ printing will also be introduced.

  14. Implementing a nationwide criteria-based emergency medical dispatch system: A register-based follow-up study

    PubMed Central

    2013-01-01

    Background A criteria-based nationwide Emergency Medical Dispatch (EMD) system was recently implemented in Denmark. We described the system and studied its ability to triage patients according to the severity of their condition by analysing hospital admission and case-fatality risks. Methods This was a register-based follow-up study of all 1-1-2 calls in a 6-month period that were triaged according to the Danish Index – the new criteria-based dispatch protocol. Danish Index data were linked with hospital and vital status data from national registries. Confidence intervals (95%) for proportions with binomial data were computed using exact methods. To test for trend the Wald test was used. Results Information on level of emergency according to the Danish Index rating was available for 67,135 patients who received ambulance service. Emergency level A (urgent cases) accounted for 51.4% (n = 34,489) of patients, emergency level B for 46.3% (n = 31,116), emergency level C for 2.1% (n = 1,391) and emergency level D for 0.2% (n = 139). For emergency level A, the median time from call receipt to ambulance dispatch was 2 min 1 s, and the median time to arrival was 6 min 11 s. Data concerning admission and case fatality was available for 55,270 patients. The hospital admission risk for emergency level A patients was 64.4% (95% CI = 63.8-64.9). There was a significant trend (p < 0.001) towards lower admission risks for patients with lower levels of emergency. The case fatality risk for emergency level A patients on the same day as the 1-1-2 call was 4.4% (95% CI = 4.1-4.6). The relative case-fatality risk among emergency level A patients compared to emergency level B–D patients was 14.3 (95% CI: 11.5-18.0). Conclusion The majority of patients were assessed as Danish Index emergency level A or B. Case fatality and hospital admission risks were substantially higher for emergency level A patients than for emergency level B–D patients. Thus

  15. Washington DC Area Computer Aided Surgery Society Monthly Meetings

    DTIC Science & Technology

    2009-03-01

    05-1-0072 TITLE: Washington DC Area Computer Aided Surgery Society Monthly Meetings PRINCIPAL INVESTIGATOR: Kevin R. Cleary, Ph.D...Feb 2005-21 Feb 2009 4. Title and Subtitle Washington DC Area Computer Aided Surgery Society Monthly Meetings 5. Award Number W81XWH-05-1-0072...Area Computer-Aided Surgery Society (WashCAS) has become the major vehicle in the Washington/Baltimore area for exploring the issues in the emerging

  16. Demand Response Dispatch Tool

    SciTech Connect

    2012-08-31

    The Demand Response (DR) Dispatch Tool uses price profiles to dispatch demand response resources and create load modifying profiles. These annual profiles are used as inputs to production cost models and regional planning tools (e.g., PROMOD). The tool has been effectively implemented in transmission planning studies conducted by the Western Electricity Coordinating Council via its Transmission Expansion Planning and Policy Committee. The DR Dispatch Tool can properly model the dispatch of DR resources for both reliability and economic conditions.

  17. Computer-Aided Fabrication System Implementation

    DTIC Science & Technology

    1988-03-31

    Another unique feature in the Taguchi method is the having the greatest generality and range of application, however, simultaneous use of "inner" and...today’s practice, the three methods of model building, Perhaps the most distinct feature of the Taguchi method is experimental, experiential, and...opposed to the nine experiments used in the number of experiments. There are two commonly used Taguchi method . methodologies for experimental design

  18. Computer-Aided Fabrication System Implementation

    DTIC Science & Technology

    1987-03-31

    Sutardja, Y. Shacham-Diamand, and W. Oldham, "Simulation of Stress Effects on the Reaction Kinectics and Oxidant Diffusion in Silicon Oxidation...a2(t) (6) Suppose the constraints for uj and V2 depend on some random processes (e.g. the machine state). We must determine Ui and U2 based on...19) If J(x, a, t) is known, then the optimal routing and scheduling policy y satisfies m_ yeü{. 3J, in jT-fy’ + y1 1 + £-( v2 + y2 1 (20

  19. Computer-aided light sheet flow visualization using photogrammetry

    NASA Technical Reports Server (NTRS)

    Stacy, Kathryn; Severance, Kurt; Childers, Brooks A.

    1994-01-01

    A computer-aided flow visualization process has been developed to analyze video images acquired from rotating and translating light sheet visualization systems. The computer process integrates a mathematical model for image reconstruction, advanced computer graphics concepts, and digital image processing to provide a quantitative and a visual analysis capability. The image reconstruction model, based on photogrammetry, uses knowledge of the camera and light sheet locations and orientations to project two-dimensional light sheet video images into three-dimensional space. A sophisticated computer visualization package, commonly used to analyze computational fluid dynamics (CFD) results, was chosen to interactively display the reconstructed light sheet images with the numerical surface geometry for the model or aircraft under study. The photogrammetric reconstruction technique and the image processing and computer graphics techniques and equipment are described. Results of the computer-aided process applied to both a wind tunnel translating light sheet experiment and an in-flight rotating light sheet experiment are presented. The capability to compare reconstructed experimental light sheet images with CFD solutions in the same graphics environment is also demonstrated.

  20. Computer-aided diagnosis of lumbar stenosis conditions

    NASA Astrophysics Data System (ADS)

    Koompairojn, Soontharee; Hua, Kathleen; Hua, Kien A.; Srisomboon, Jintavaree

    2010-03-01

    Computer-aided diagnosis (CAD) systems are indispensable tools for patients' healthcare in modern medicine. Nevertheless, the only fully automatic CAD system available for lumbar stenosis today is for X-ray images. Its performance is limited due to the limitations intrinsic to X-ray images. In this paper, we present a system for magnetic resonance images. It employs a machine learning classification technique to automatically recognize lumbar spine components. Features can then be extracted from these spinal components. Finally, diagnosis is done by applying a Multilayer Perceptron. This classification framework can learn the features of different spinal conditions from the training images. The trained Perceptron can then be applied to diagnose new cases for various spinal conditions. Our experimental studies based on 62 subjects indicate that the proposed system is reliable and significantly better than our older system for X-ray images.

  1. PACS-Based Computer-Aided Detection and Diagnosis

    NASA Astrophysics Data System (ADS)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  2. Computer aided lytic bone metastasis detection using regular CT images

    NASA Astrophysics Data System (ADS)

    Yao, Jianhua; O'Connor, Stacy D.; Summers, Ronald

    2006-03-01

    This paper presents a computer aided detection system to find lytic bone metastases in the spine. The CAD system is designed to run on routine chest and/or abdominal CT exams (5mm slice thickness) obtained during a patient's evaluation for other indications. The system can therefore serve as a background procedure to detect bone metastases. The spine is first automatically extracted based on adaptive thresholding, morphological operation, and region growing. The spinal cord is then traced from thoracic spine to lumbar spine using a dynamic graph search to set up a local spine coordinate system. A watershed algorithm is then applied to detect potential lytic bone lesions. A set of 26 quantitative features (density, shape and location) are computed for each detection. After a filter on the features, Support Vector Machines (SVM) are used as classifiers to determine if a detection is a true lesion. The SVM was trained using ground truth segmentation manually defined by experts.

  3. Fracture resistance of computer-aided design/computer-aided manufacturing-generated composite resin-based molar crowns.

    PubMed

    Harada, Akio; Nakamura, Keisuke; Kanno, Taro; Inagaki, Ryoichi; Örtengren, Ulf; Niwano, Yoshimi; Sasaki, Keiichi; Egusa, Hiroshi

    2015-04-01

    The aim of this study was to investigate whether different fabrication processes, such as the computer-aided design/computer-aided manufacturing (CAD/CAM) system or the manual build-up technique, affect the fracture resistance of composite resin-based crowns. Lava Ultimate (LU), Estenia C&B (EC&B), and lithium disilicate glass-ceramic IPS e.max press (EMP) were used. Four types of molar crowns were fabricated: CAD/CAM-generated composite resin-based crowns (LU crowns); manually built-up monolayer composite resin-based crowns (EC&B-monolayer crowns); manually built-up layered composite resin-based crowns (EC&B-layered crowns); and EMP crowns. Each type of crown was cemented to dies and the fracture resistance was tested. EC&B-layered crowns showed significantly lower fracture resistance compared with LU and EMP crowns, although there was no significant difference in flexural strength or fracture toughness between LU and EC&B materials. Micro-computed tomography and fractographic analysis showed that decreased strength probably resulted from internal voids in the EC&B-layered crowns introduced by the layering process. There was no significant difference in fracture resistance among LU, EC&B-monolayer, and EMP crowns. Both types of composite resin-based crowns showed fracture loads of >2000 N, which is higher than the molar bite force. Therefore, CAD/CAM-generated crowns, without internal defects, may be applied to molar regions with sufficient fracture resistance.

  4. Analysis of dispatching rules in a stochastic dynamic job shop manufacturing system with sequence-dependent setup times

    NASA Astrophysics Data System (ADS)

    Sharma, Pankaj; Jain, Ajai

    2014-12-01

    Stochastic dynamic job shop scheduling problem with consideration of sequence-dependent setup times are among the most difficult classes of scheduling problems. This paper assesses the performance of nine dispatching rules in such shop from makespan, mean flow time, maximum flow time, mean tardiness, maximum tardiness, number of tardy jobs, total setups and mean setup time performance measures viewpoint. A discrete event simulation model of a stochastic dynamic job shop manufacturing system is developed for investigation purpose. Nine dispatching rules identified from literature are incorporated in the simulation model. The simulation experiments are conducted under due date tightness factor of 3, shop utilization percentage of 90% and setup times less than processing times. Results indicate that shortest setup time (SIMSET) rule provides the best performance for mean flow time and number of tardy jobs measures. The job with similar setup and modified earliest due date (JMEDD) rule provides the best performance for makespan, maximum flow time, mean tardiness, maximum tardiness, total setups and mean setup time measures.

  5. A Suggested Computer Aided Drafting Curriculum (Dacum Based).

    ERIC Educational Resources Information Center

    Pedras, Melvin J.; Hoggard, David

    Computer-aided drawing can bring new technology into the drafting classroom. One approach to computer-aided drafting (CAD) involves use of a personal computer and purchased software. Existing school computers could be shared to reduce costs. Following this narrative introduction, a suggested curriculum for the teaching of CAD is presented in…

  6. Computer-Aided Parallelizer and Optimizer

    NASA Technical Reports Server (NTRS)

    Jin, Haoqiang

    2011-01-01

    The Computer-Aided Parallelizer and Optimizer (CAPO) automates the insertion of compiler directives (see figure) to facilitate parallel processing on Shared Memory Parallel (SMP) machines. While CAPO currently is integrated seamlessly into CAPTools (developed at the University of Greenwich, now marketed as ParaWise), CAPO was independently developed at Ames Research Center as one of the components for the Legacy Code Modernization (LCM) project. The current version takes serial FORTRAN programs, performs interprocedural data dependence analysis, and generates OpenMP directives. Due to the widely supported OpenMP standard, the generated OpenMP codes have the potential to run on a wide range of SMP machines. CAPO relies on accurate interprocedural data dependence information currently provided by CAPTools. Compiler directives are generated through identification of parallel loops in the outermost level, construction of parallel regions around parallel loops and optimization of parallel regions, and insertion of directives with automatic identification of private, reduction, induction, and shared variables. Attempts also have been made to identify potential pipeline parallelism (implemented with point-to-point synchronization). Although directives are generated automatically, user interaction with the tool is still important for producing good parallel codes. A comprehensive graphical user interface is included for users to interact with the parallelization process.

  7. Computer-aided design for metabolic engineering.

    PubMed

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes.

  8. Computer-Aided Socket Design For Amputees

    NASA Astrophysics Data System (ADS)

    Novicov, Aleksey; Foort, James

    1983-07-01

    The fitting of sockets and artificial legs to amputees' stumps is a difficult and lengthy process that can take numerous trials. It has been proposed that most amputees can be fitted with a standard socket shape with minimal changes to the socket. To perform this task, a procedure is being developed at the Medical Engineering Resource Unit for computer aided socket design for amputees. An interactive PASCAL program, operating on a microcomputer, will prompt the operator (or prosthetist) by asking him to determine the condition of the stump. While the operator is inputing this information into the computer, together with a few critical anatomical measurements, a standard socket shape, viewed on the video monitor, will begin to change. Throughout the "shape fitting" procedure, the operator will have the ability to modify the socket shape on the screen with the use of a light pen. It will also be possible to view various cross-sections and different perspectives. The shape fitting procedure continues until a suitable socket shape is designed. Future efforts will focus on transferring the computer designed socket into a physical socket. The overall goal is to provide amputees with a better fit in less time and to objectify socket fitting so that new prosthetists may be easily taught.

  9. Computer-Aided Drug Design Methods.

    PubMed

    Yu, Wenbo; MacKerell, Alexander D

    2017-01-01

    Computational approaches are useful tools to interpret and guide experiments to expedite the antibiotic drug design process. Structure-based drug design (SBDD) and ligand-based drug design (LBDD) are the two general types of computer-aided drug design (CADD) approaches in existence. SBDD methods analyze macromolecular target 3-dimensional structural information, typically of proteins or RNA, to identify key sites and interactions that are important for their respective biological functions. Such information can then be utilized to design antibiotic drugs that can compete with essential interactions involving the target and thus interrupt the biological pathways essential for survival of the microorganism(s). LBDD methods focus on known antibiotic ligands for a target to establish a relationship between their physiochemical properties and antibiotic activities, referred to as a structure-activity relationship (SAR), information that can be used for optimization of known drugs or guide the design of new drugs with improved activity. In this chapter, standard CADD protocols for both SBDD and LBDD will be presented with a special focus on methodologies and targets routinely studied in our laboratory for antibiotic drug discoveries.

  10. On computer-aided design of aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Sobieszczanski, J. E.; Voigt, S. J.; Fulton, R. E.

    1974-01-01

    Digital computers are being used in many engineering activities to support design work. This paper provides an overview of some of this work as it relates to the design of aerospace vehicles. Discussions are given of some of the complexities of the design process which lead to large design costs and time. A number of important but disjointed computer capabilities have evolved over the years in analysis, optimization, and graphics, and such capabilities aid in addressing the problem of design complexity. Examples of existing computer-aided design (CAD) systems are given and trends for future CAD systems are indicated, as well as their relationship to pertinent data management technology. It is suggested that major gains in design capability will occur through continued development of CAD methodology and that these gains may be accelerated through a large focused effort.

  11. Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models

    NASA Technical Reports Server (NTRS)

    Jones, William T.; Lazzara, David; Haimes, Robert

    2010-01-01

    The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.

  12. The Computer Aided Aircraft-design Package (CAAP)

    NASA Technical Reports Server (NTRS)

    Yalif, Guy U.

    1994-01-01

    The preliminary design of an aircraft is a complex, labor-intensive, and creative process. Since the 1970's, many computer programs have been written to help automate preliminary airplane design. Time and resource analyses have identified, 'a substantial decrease in project duration with the introduction of an automated design capability'. Proof-of-concept studies have been completed which establish 'a foundation for a computer-based airframe design capability', Unfortunately, today's design codes exist in many different languages on many, often expensive, hardware platforms. Through the use of a module-based system architecture, the Computer aided Aircraft-design Package (CAAP) will eventually bring together many of the most useful features of existing programs. Through the use of an expert system, it will add an additional feature that could be described as indispensable to entry level engineers and students: the incorporation of 'expert' knowledge into the automated design process.

  13. Computer-aided boundary delineation of agricultural lands

    NASA Technical Reports Server (NTRS)

    Cheng, Thomas D.; Angelici, Gary L.; Slye, Robert E.; Ma, Matt

    1989-01-01

    The National Agricultural Statistics Service of the United States Department of Agriculture (USDA) presently uses labor-intensive aerial photographic interpretation techniques to divide large geographical areas into manageable-sized units for estimating domestic crop and livestock production. Prototype software, the computer-aided stratification (CAS) system, was developed to automate the procedure, and currently runs on a Sun-based image processing system. With a background display of LANDSAT Thematic Mapper and United States Geological Survey Digital Line Graph data, the operator uses a cursor to delineate agricultural areas, called sampling units, which are assigned to strata of land-use and land-cover types. The resultant stratified sampling units are used as input into subsequent USDA sampling procedures. As a test, three counties in Missouri were chosen for application of the CAS procedures. Subsequent analysis indicates that CAS was five times faster in creating sampling units than the manual techniques were.

  14. Computers in engineering 1983; Proceedings of the International Conference and Exhibit, Chicago, IL, August 7-11, 1983. Volume 1 - Computer-aided design, manufacturing, and simulation

    NASA Astrophysics Data System (ADS)

    Cokonis, T. J.

    The papers presented in this volume provide examples of the impact of computers on present engineering practice and indicate some future trends in computer-aided design, manufacturing, and simulation. Topics discussed include computer-aided design of turbine cycle configuration, managing and development of engineering computer systems, computer-aided manufacturing with robots in the automotive industry, and computer-aided design/analysis techniques of composite materials in the cure phase. Papers are also presented on computer simulation of vehicular propulsion systems, the performance of a hydraulic system simulator in a CAD environment, and computer simulation of hovercraft heave dynamics and control.

  15. Computer-aided diagnosis of alcoholism-related EEG signals.

    PubMed

    Acharya, U Rajendra; S, Vidya; Bhat, Shreya; Adeli, Hojjat; Adeli, Amir

    2014-12-01

    Alcoholism is a severe disorder that affects the functionality of neurons in the central nervous system (CNS) and alters the behavior of the affected person. Electroencephalogram (EEG) signals can be used as a diagnostic tool in the evaluation of subjects with alcoholism. The neurophysiological interpretation of EEG signals in persons with alcoholism (PWA) is based on observation and interpretation of the frequency and power in their EEGs compared to EEG signals from persons without alcoholism. This paper presents a review of the known features of EEGs obtained from PWA and proposes that the impact of alcoholism on the brain can be determined by computer-aided analysis of EEGs through extracting the minute variations in the EEG signals that can differentiate the EEGs of PWA from those of nonaffected persons. The authors advance the idea of automated computer-aided diagnosis (CAD) of alcoholism by employing the EEG signals. This is achieved through judicious combination of signal processing techniques such as wavelet, nonlinear dynamics, and chaos theory and pattern recognition and classification techniques. A CAD system is cost-effective and efficient and can be used as a decision support system by physicians in the diagnosis and treatment of alcoholism especially those who do not specialize in alcoholism or neurophysiology. It can also be of great value to rehabilitation centers to assess PWA over time and to monitor the impact of treatment aimed at minimizing or reversing the effects of the disease on the brain. A CAD system can be used to determine the extent of alcoholism-related changes in EEG signals (low, medium, high) and the effectiveness of therapeutic plans.

  16. Computer aided analysis, simulation and optimisation of thermal sterilisation processes.

    PubMed

    Narayanan, C M; Banerjee, Arindam

    2013-04-01

    Although thermal sterilisation is a widely employed industrial process, little work is reported in the available literature including patents on the mathematical analysis and simulation of these processes. In the present work, software packages have been developed for computer aided optimum design of thermal sterilisation processes. Systems involving steam sparging, jacketed heating/cooling, helical coils submerged in agitated vessels and systems that employ external heat exchangers (double pipe, shell and tube and plate exchangers) have been considered. Both batch and continuous operations have been analysed and simulated. The dependence of del factor on system / operating parameters such as mass or volume of substrate to be sterilised per batch, speed of agitation, helix diameter, substrate to steam ratio, rate of substrate circulation through heat exchanger and that through holding tube have been analysed separately for each mode of sterilisation. Axial dispersion in the holding tube has also been adequately accounted for through an appropriately defined axial dispersion coefficient. The effect of exchanger characteristics/specifications on the system performance has also been analysed. The multiparameter computer aided design (CAD) software packages prepared are thus highly versatile in nature and they permit to make the most optimum choice of operating variables for the processes selected. The computed results have been compared with extensive data collected from a number of industries (distilleries, food processing and pharmaceutical industries) and pilot plants and satisfactory agreement has been observed between the two, thereby ascertaining the accuracy of the CAD softwares developed. No simplifying assumptions have been made during the analysis and the design of associated heating / cooling equipment has been performed utilising the most updated design correlations and computer softwares.

  17. Single-tooth dento-osseous osteotomy with a computer-aided design/computer-aided manufacturing surgical guide.

    PubMed

    Kang, Sang-Hoon; Kim, Moon-Key; Lee, Ji-Yeon

    2016-04-01

    This clinical note introduces a method to assist surgeons in performing single-tooth dento-osseous osteotomy. For use in this method, a surgical guide was manufactured using computer-aided design/computer-aided manufacturing technology and was based on preoperative surgical simulation data. This method was highly conducive to successful single-tooth dento-osseous segmental osteotomy.

  18. CAD/CAM (Computer Aided Design/Computer Aided Manufacture). A Brief Guide to Materials in the Library of Congress.

    ERIC Educational Resources Information Center

    Havas, George D.

    This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…

  19. Retrofitting a crown to a sleep apnea device by using computer-aided design and computer-aided milling technology.

    PubMed

    Biethman, Rick; Land, Martin F; Hruskocy, Heather; Colgin, Bruce

    2014-07-01

    Retrofitting a new crown to an existing dental device is challenging. The continued evolution of computer-aided design and computer-aided manufacturing (CAD/CAM) significantly simplifies the process. This article demonstrates retrofitting a gold crown to an existing sleep apnea device.

  20. Single-tooth dento-osseous osteotomy with a computer-aided design/computer-aided manufacturing surgical guide

    PubMed Central

    2016-01-01

    This clinical note introduces a method to assist surgeons in performing single-tooth dento-osseous osteotomy. For use in this method, a surgical guide was manufactured using computer-aided design/computer-aided manufacturing technology and was based on preoperative surgical simulation data. This method was highly conducive to successful single-tooth dento-osseous segmental osteotomy. PMID:27162756

  1. Pilot decision making in a computer-aided flight management situation

    NASA Technical Reports Server (NTRS)

    Chu, Y. Y.; Rouse, W. B.

    1978-01-01

    An experimental representation of a computer-aided multi-task flight management situation has been developed. A computer aiding program was implemented to serve as a back-up decision maker. An experiment was conducted with a balanced design of several subject runs for different workload levels. This was achieved using three levels of subsystem event arrival rates, three levels of control task involvement, and three levels of availability of computer aiding. Experimental results compared quite favorably with those from a computer simulation which employed a queueing model. It was shown that the aiding had enhanced system performance as well as subjective ratings, and that the adaptive aiding policy further reduced subsystem delay.

  2. Decision trees and integrated features for computer aided mammographic screening

    SciTech Connect

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  3. Computer Aided Design Of Electrical Machines For Variable Speed Applications.

    NASA Astrophysics Data System (ADS)

    Krishnan, R.; Aravind, S.; Materu, P.

    1987-10-01

    In recent years, the product life cycle has decreased and demands for new products have emerged due to competition, modern industrial needs and rapidly changing technology. This has necessitated changes in design, development and manufacturing processes so as to improve quality and efficiency as well as reducing costs. Computer Aided Design (CAD) helps to meet this challenge in the design evaluation and final product design stages. This paper presents the development of an interactive software for the optimal design of a motor intended for variable speed applications. The use of finite element analysis methods is proposed as an indispensable part of the CAD system for electrical machine design. An illustration of the method is given for the design of a switched reluctance motor.

  4. Computer-Aided Air-Traffic Control In The Terminal Area

    NASA Technical Reports Server (NTRS)

    Erzberger, Heinz

    1995-01-01

    Developmental computer-aided system for automated management and control of arrival traffic at large airport includes three integrated subsystems. One subsystem, called Traffic Management Advisor, another subsystem, called Descent Advisor, and third subsystem, called Final Approach Spacing Tool. Data base that includes current wind measurements and mathematical models of performances of types of aircraft contributes to effective operation of system.

  5. The Computer-Aided Analytic Process Model. Operations Handbook for the Analytic Process Model Demonstration Package

    DTIC Science & Technology

    1986-01-01

    Research Note 86-06 THE COMPUTER-AIDED ANALYTIC PROCESS MODEL : OPERATIONS HANDBOOK FOR THE ANALYTIC PROCESS MODEL DE ONSTRATION PACKAGE Ronald G...ic Process Model ; Operations Handbook; Tutorial; Apple; Systems Taxonomy Mod--l; Training System; Bradl1ey infantry Fighting * Vehicle; BIFV...8217. . . . . . . .. . . . . . . . . . . . . . . . * - ~ . - - * m- .. . . . . . . item 20. Abstract -continued companion volume-- "The Analytic Process Model for

  6. Data Management Standards in Computer-aided Acquisition and Logistic Support (CALS)

    NASA Technical Reports Server (NTRS)

    Jefferson, David K.

    1990-01-01

    Viewgraphs and discussion on data management standards in computer-aided acquisition and logistic support (CALS) are presented. CALS is intended to reduce cost, increase quality, and improve timeliness of weapon system acquisition and support by greatly improving the flow of technical information. The phase 2 standards, industrial environment, are discussed. The information resource dictionary system (IRDS) is described.

  7. The Power of Computer-aided Tomography to Investigate Marine Benthic Communities

    EPA Science Inventory

    Utilization of Computer-aided-Tomography (CT) technology is a powerful tool to investigate benthic communities in aquatic systems. In this presentation, we will attempt to summarize our 15 years of experience in developing specific CT methods and applications to marine benthic co...

  8. Telephone CPR Instructions in Emergency Dispatch Systems: Qualitative Survey of 911 Call Centers

    PubMed Central

    Sutter, John; Panczyk, Micah; Spaite, Daniel W.; Ferrer, Jose Maria E.; Roosa, Jason; Dameff, Christian; Langlais, Blake; Murphy, Ryan A.; Bobrow, Bentley J.

    2015-01-01

    Introduction Out-of-hospital cardiac arrest (OHCA) is a leading cause of death. The 2010 American Heart Association Emergency Cardiovascular Care (ECC) Guidelines recognize emergency dispatch as an integral component of emergency medical service response to OHCA and call for all dispatchers to be trained to provide telephone cardiopulmonary resuscitation (T-CPR) pre-arrival instructions. To begin to measure and improve this critical intervention, this study describes a nationwide survey of public safety answering points (PSAPs) focusing on the current practices and resources available to provide T-CPR to callers with the overall goal of improving survival from OHCA. Methods We conducted this survey in 2010, identifying 5,686 PSAPs; 3,555 had valid e-mail addresses and were contacted. Each received a preliminary e-mail announcing the survey, an e-mail with a link to the survey, and up to three follow-up e-mails for non-responders. The survey contained 23 primary questions with sub-questions depending on the response selected. Results Of the 5,686 identified PSAPs in the United States, 3,555 (63%) received the survey, with 1,924/3,555 (54%) responding. Nearly all were public agencies (n=1,888, 98%). Eight hundred seventy-eight (46%) responding agencies reported that they provide no instructions for medical emergencies, and 273 (14%) reported that they are unable to transfer callers to another facility to provide T-CPR. Of the 1,924 respondents, 975 (51%) reported that they provide pre-arrival instructions for OHCA: 67 (3%) provide compression-only CPR instructions, 699 (36%) reported traditional CPR instructions (chest compressions with rescue breathing), 166 (9%) reported some other instructions incorporating ventilations and compressions, and 92 (5%) did not specify the type of instructions provided. A validation follow up showed no substantial difference in the provision of instructions for OHCA by non-responders to the survey. Conclusion This is the first large

  9. Microcomputed tomography marginal fit evaluation of computer-aided design/computer-aided manufacturing crowns with different methods of virtual model acquisition.

    PubMed

    das Neves, Flavio Domingues; do Prado, Celio Jesus; Prudente, Marcel Santana; Carneiro, Thiago Almeida Prado Naves; Zancope, Karla; Davi, Leticia Resende; Mendonca, Gustavo; Cooper, Lyndon; Soares, Carlos Jose

    2015-01-01

    This in vitro study used microcomputed tomography to evaluate the marginal fit of crowns fabricated using a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with different methods of virtual model acquisition. Crowns were fabricated to fit in a cast containing a single human premolar. Four methods of virtual model acquisition were used: Group 1 (control), digital impressioning of a typodont; Group 2, digital impressioning of a powdered typodont; Group 3, digital impressioning of a regular impression; and Group 4, digital impressioning of a master cast. Statistically significant differences were found between the marginal gap of Group 2 and the other groups (P < 0.05); no differences were found among Groups 1, 3, and 4. The results showed that crowns fabricated using the chairside CAD/CAM system exhibited significantly smaller vertical misfit when a thin layer of powder was applied over the typodont before digital impressioning.

  10. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    PubMed Central

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  11. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  12. Electromagnetic tracking for abdominal interventions in computer aided surgery.

    PubMed

    Zhang, Hui; Banovac, Filip; Lin, Ralph; Glossop, Neil; Wood, Bradford J; Lindisch, David; Levy, Elliot; Cleary, Kevin

    2006-05-01

    Electromagnetic tracking has great potential for assisting physicians in precision placement of instruments during minimally invasive interventions in the abdomen, since electromagnetic tracking is not limited by the line-of-sight restrictions of optical tracking. A new generation of electromagnetic tracking has recently become available, with sensors small enough to be included in the tips of instruments. To fully exploit the potential of this technology, our research group has been developing a computer aided, image-guided system that uses electromagnetic tracking for visualization of the internal anatomy during abdominal interventions. As registration is a critical component in developing an accurate image-guided system, we present three registration techniques: 1) enhanced paired-point registration (time-stamp match registration and dynamic registration); 2) orientation-based registration; and 3) needle shape-based registration. Respiration compensation is another important issue, particularly in the abdomen, where respiratory motion can make precise targeting difficult. To address this problem, we propose reference tracking and affine transformation methods. Finally, we present our prototype navigation system, which integrates the registration, segmentation, path-planning and navigation functions to provide real-time image guidance in the clinical environment. The methods presented here have been tested with a respiratory phantom specially designed by our group and in swine animal studies under approved protocols. Based on these tests, we conclude that our system can provide quick and accurate localization of tracked instruments in abdominal interventions, and that it offers a user-friendly display for the physician.

  13. Computer-Aided Sensor Development Focused on Security Issues.

    PubMed

    Bialas, Andrzej

    2016-05-26

    The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  14. Computer-Aided Sensor Development Focused on Security Issues

    PubMed Central

    Bialas, Andrzej

    2016-01-01

    The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research. PMID:27240360

  15. Orthodontics: computer-aided diagnosis and treatment planning

    NASA Astrophysics Data System (ADS)

    Yi, Yaxing; Li, Zhongke; Wei, Suyuan; Deng, Fanglin; Yao, Sen

    2000-10-01

    The purpose of this article is to introduce the outline of our newly developed computer-aided 3D dental cast analyzing system with laser scanning, and its preliminary clinical applications. The system is composed of a scanning device and a personal computer as a scanning controller and post processor. The scanning device is composed of a laser beam emitter, two sets of linear CCD cameras and a table which is rotatable by two-degree-of-freedom. The rotating is controlled precisely by a personal computer. The dental cast is projected and scanned with a laser beam. Triangulation is applied to determine the location of each point. Generation of 3D graphics of the dental cast takes approximately 40 minutes. About 170,000 sets of X,Y,Z coordinates are store for one dental cast. Besides the conventional linear and angular measurements of the dental cast, we are also able to demonstrate the size of the top surface area of each molar. The advantage of this system is that it facilitates the otherwise complicated and time- consuming mock surgery necessary for treatment planning in orthognathic surgery.

  16. Multi-community command and control systems in law enforcement: An introductory planning guide

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.; Garcia, E. A.; Kennedy, R. D.

    1976-01-01

    A set of planning guidelines for multi-community command and control systems in law enforcement is presented. Essential characteristics and applications of these systems are outlined. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Program management techniques and joint powers agreements for multicommunity programs are discussed in detail. A description of a typical multi-community computer-aided dispatch system is appended.

  17. Accounting for the effects of power system controllers and stability on power dispatch and electricity market prices

    NASA Astrophysics Data System (ADS)

    Kodsi, Sameh K. M.

    Recently, the widespread use of power system controllers, such as PSS and FACTS controllers, has led to the analysis of their effect on the overall stability of power systems. Many studies have been conducted to allocate FACTS controllers so that they achieve optimal power flow conditions in the context of Optimal Power Flow (OPF) analysis. However, these studies usually do not examine the effect of these controllers on the voltage and angle stability of the entire system, considering that the types of these controllers and their control signals, such as reactive power, current, or voltage, have significant effect on the entire system stability. Due to the recent transition from government controlled to deregulated electricity markets, the relationship between power system controllers and electricity markets has added a new dimension, as the effect of these controllers on the overall power system stability has to be seen from an economic point of view. Studying the effect of adding and tuning these controllers on the pricing of electricity within the context of electricity markets is a significant and novel research area. Specifically, the link among stability, FACTS controllers and electricity pricing should be appropriately studied and modelled. Consequently, in this thesis, the focus is on proposing and describing of a novel OPF technique which includes a new stability constraint. This technique is compared with respect to existent OPF techniques, demonstrating that it provides an appropriate modelling of system controllers, and thus a better understanding of their effects on system stability and energy pricing. The proposed OPF technique offers a new methodology for pricing the dynamic services provided by the system's controllers. Moreover, the new OPF technique can be used to develop a novel tuning methodology for PSS and FACTS controllers to optimize power dispatch and price levels, as guaranteeing an adequate level of system security. All tests and

  18. Accelerating Battery Design Using Computer-Aided Engineering Tools: Preprint

    SciTech Connect

    Pesaran, A.; Heon, G. H.; Smith, K.

    2011-01-01

    Computer-aided engineering (CAE) is a proven pathway, especially in the automotive industry, to improve performance by resolving the relevant physics in complex systems, shortening the product development design cycle, thus reducing cost, and providing an efficient way to evaluate parameters for robust designs. Academic models include the relevant physics details, but neglect engineering complexities. Industry models include the relevant macroscopic geometry and system conditions, but simplify the fundamental physics too much. Most of the CAE battery tools for in-house use are custom model codes and require expert users. There is a need to make these battery modeling and design tools more accessible to end users such as battery developers, pack integrators, and vehicle makers. Developing integrated and physics-based CAE battery tools can reduce the design, build, test, break, re-design, re-build, and re-test cycle and help lower costs. NREL has been involved in developing various models to predict the thermal and electrochemical performance of large-format cells and has used in commercial three-dimensional finite-element analysis and computational fluid dynamics to study battery pack thermal issues. These NREL cell and pack design tools can be integrated to help support the automotive industry and to accelerate battery design.

  19. Computer-aided kidney segmentation on abdominal CT images.

    PubMed

    Lin, Daw-Tung; Lei, Chung-Chih; Hung, Siu-Wan

    2006-01-01

    In this paper, an effective model-based approach for computer-aided kidney segmentation of abdominal CT images with anatomic structure consideration is presented. This automatic segmentation system is expected to assist physicians in both clinical diagnosis and educational training. The proposed method is a coarse to fine segmentation approach divided into two stages. First, the candidate kidney region is extracted according to the statistical geometric location of kidney within the abdomen. This approach is applicable to images of different sizes by using the relative distance of the kidney region to the spine. The second stage identifies the kidney by a series of image processing operations. The main elements of the proposed system are: 1) the location of the spine is used as the landmark for coordinate references; 2) elliptic candidate kidney region extraction with progressive positioning on the consecutive CT images; 3) novel directional model for a more reliable kidney region seed point identification; and 4) adaptive region growing controlled by the properties of image homogeneity. In addition, in order to provide different views for the physicians, we have implemented a visualization tool that will automatically show the renal contour through the method of second-order neighborhood edge detection. We considered segmentation of kidney regions from CT scans that contain pathologies in clinical practice. The results of a series of tests on 358 images from 30 patients indicate an average correlation coefficient of up to 88% between automatic and manual segmentation.

  20. Computer-aided detection of colonic polyps using volume rendering

    NASA Astrophysics Data System (ADS)

    Hong, Wei; Qiu, Feng; Marino, Joseph; Kaufman, Arie

    2007-03-01

    This work utilizes a novel pipeline for the computer-aided detection (CAD) of colonic polyps, assisting radiologists in locating polyps when using a virtual colonoscopy system. Our CAD pipeline automatically detects polyps while reducing the number of false positives (FPs). It integrates volume rendering and conformal colon flattening with texture and shape analysis. The colon is first digitally cleansed, segmented, and extracted from the CT dataset of the abdomen. The colon surface is then mapped to a 2D rectangle using conformal mapping. Using this colon flattening method, the CAD problem is converted from 3D into 2D. The flattened image is rendered using a direct volume rendering of the 3D colon dataset with a translucent transfer function. Suspicious polyps are detected by applying a clustering method on the 2D volume rendered image. The FPs are reduced by analyzing shape and texture features of the suspicious areas detected by the clustering step. Compared with shape-based methods, ours is much faster and much more efficient as it avoids computing curvature and other shape parameters for the whole colon wall. We tested our method with 178 datasets and found it to be 100% sensitive to adenomatous polyps with a low rate of FPs. The CAD results are seamlessly integrated into a virtual colonoscopy system, providing the radiologists with visual cues and likelihood indicators of areas likely to contain polyps, and allowing them to quickly inspect the suspicious areas and further exploit the flattened colon view for easy navigation and bookmark placement.

  1. Computer Aided Detection of SARS Based on Radiographs Data Mining.

    PubMed

    Xuanyang, Xie; Yuchang, Gong; Shouhong, Wan; Xi, Li

    2005-01-01

    This paper introduces our work on how to use image mining techniques to detect SARS, the severe acute respiratory syndrome, automatically as the prototype of computer aided detection/diagnosis (CAD) system. Data used in this paper are digitalized PA(posterior anterior) X-ray images stored in the real-life picture archiving and communication system (PACS) of the 2nd Affiliation Hospital of Guangzhou Medical College. Association rule mining was applied first but results showed there was no significant difference between the locations of the lesions or infiltrate. Classification based on image textures was performed. A sample set contains both the pneumonia and SARS X-ray images was built in the first place. After modeling each sample by a feature vector, the sample set was partitioned to match the detection purpose: classification. Three methods were used: C4.5, neural network (NN) and CART. Final result shows that 70.94% SARS cases can be detected by CART. Data preparation, segmentation, feature extraction and data mining steps, with corresponding techniques are included in this paper. ROC charts and confusion matrix by all three methods are given and analyzed.

  2. Multi-Fluid Geothermal Energy Systems: Using CO2 for Dispatchable Renewable Power Generation and Grid Stabilization

    NASA Astrophysics Data System (ADS)

    Buscheck, T. A.; Bielicki, J. M.; Randolph, J.; Chen, M.; Hao, Y.; Sun, Y.

    2013-12-01

    Abstract We present an approach to use CO2 to (1) generate dispatchable renewable power that can quickly respond to grid fluctuations and be cost-competitive with natural gas, (2) stabilize the grid by efficiently storing large quantities of energy, (3) enable seasonal storage of solar thermal energy for grid integration, (4) produce brine for power-plant cooling, all which (5) increase CO2 value, rendering CO2 capture to be commerically viable, while (6) sequestering huge quantities of CO2. These attributes reduce carbon intensity of electric power, and enable cost-competitive, dispatchable power from major sources of renewable energy: wind, solar, and geothermal. Conventional geothermal power systems circulate brine as the working fluid to extract heat, but the parasitic power load for this circulation can consume a large portion of gross power output. Recently, CO2 has been considered as a working fluid because its advantageous properties reduce this parasitic loss. We expand on this idea by using multiple working fluids: brine, CO2, and N2. N2 can be separated from air at lower cost than captured CO2, it is not corrosive, and it will not react with the formation. N2 also can improve the economics of energy production and enable energy storage, while reducing operational risk. Extracting heat from geothermal reservoirs often requires submersible pumps to lift brine, but these pumps consume much of the generated electricity. In contrast, our approach drives fluid circulation by injecting supplemental, compressible fluids (CO2, and N2) with high coefficients of thermal expansion. These fluids augment reservoir pressure, produce artesian flow at the producers, and reduce the parasitic load. Pressure augmentation is improved by the thermosiphon effect that results from injecting cold/dense CO2 and N2. These fluids are heated to reservoir temperature, greatly expand, and increase the artesian flow of brine and supplemental fluid at the producers. Rather than using

  3. The future of computer-aided sperm analysis

    PubMed Central

    Mortimer, Sharon T; van der Horst, Gerhard; Mortimer, David

    2015-01-01

    Computer-aided sperm analysis (CASA) technology was developed in the late 1980s for analyzing sperm movement characteristics or kinematics and has been highly successful in enabling this field of research. CASA has also been used with great success for measuring semen characteristics such as sperm concentration and proportions of progressive motility in many animal species, including wide application in domesticated animal production laboratories and reproductive toxicology. However, attempts to use CASA for human clinical semen analysis have largely met with poor success due to the inherent difficulties presented by many human semen samples caused by sperm clumping and heavy background debris that, until now, have precluded accurate digital image analysis. The authors review the improved capabilities of two modern CASA platforms (Hamilton Thorne CASA-II and Microptic SCA6) and consider their current and future applications with particular reference to directing our focus towards using this technology to assess functional rather than simple descriptive characteristics of spermatozoa. Specific requirements for validating CASA technology as a semi-automated system for human semen analysis are also provided, with particular reference to the accuracy and uncertainty of measurement expected of a robust medical laboratory test for implementation in clinical laboratories operating according to modern accreditation standards. PMID:25926614

  4. CART V: recent advancements in computer-aided camouflage assessment

    NASA Astrophysics Data System (ADS)

    Müller, Thomas; Müller, Markus

    2011-05-01

    In order to facilitate systematic, computer aided improvements of camouflage and concealment assessment methods, the software system CART (Camouflage Assessment in Real-Time) was built up for the camouflage assessment of objects in multispectral image sequences (see contributions to SPIE 2007-2010 [1], [2], [3], [4]). It comprises a semi-automatic marking of target objects (ground truth generation) including their propagation over the image sequence and the evaluation via user-defined feature extractors as well as methods to assess the object's movement conspicuity. In this fifth part in an annual series at the SPIE conference in Orlando, this paper presents the enhancements over the recent year and addresses the camouflage assessment of static and moving objects in multispectral image data that can show noise or image artefacts. The presented methods fathom the correlations between image processing and camouflage assessment. A novel algorithm is presented based on template matching to assess the structural inconspicuity of an object objectively and quantitatively. The results can easily be combined with an MTI (moving target indication) based movement conspicuity assessment function in order to explore the influence of object movement to a camouflage effect in different environments. As the results show, the presented methods contribute to a significant benefit in the field of camouflage assessment.

  5. Computer Aided Setup Planning Using Tolerance Analysis for Prismatic Components

    NASA Astrophysics Data System (ADS)

    Vahid, Abedini; Mohsen, Shakeri; Sajad, Kafashi

    2011-01-01

    Computer aided process planning (CAPP) is the bridge between CAD and CAM. Setup planning is the major key to transform design concept into manufacturing domain, which is mainly experience based activity in modern manufacturing industry. Setup planning is a complicated non-linear task constrained by many factors such as tool approach direction, geometric feature relationship, fixturing constrain, tolerance requirement and manufacturing practice. The objective of setup planning is to determine the number of setup needed, the orientation of the workpiece and the machining surfaces in each setup. This paper focuses on the development of a formalized procedure for automatic generation of setup plan. Tolerance relations are used as critical constraints for setup planning. The tasks that are performed are: (a) identifying groups of features that can be machined in a single setup, (b) determining a suitable work piece orientation, i.e. the suitable datum planes for each setup, (c) determining all the feasible setup plans to machine the given set of features of prismatic parts, and (d) evaluating the feasible setup plans on the basis of technological conditions. Trial runs with industrial parts indicate that the system is applicable for industrial use.

  6. Computer aided lung cancer diagnosis with deep learning algorithms

    NASA Astrophysics Data System (ADS)

    Sun, Wenqing; Zheng, Bin; Qian, Wei

    2016-03-01

    Deep learning is considered as a popular and powerful method in pattern recognition and classification. However, there are not many deep structured applications used in medical imaging diagnosis area, because large dataset is not always available for medical images. In this study we tested the feasibility of using deep learning algorithms for lung cancer diagnosis with the cases from Lung Image Database Consortium (LIDC) database. The nodules on each computed tomography (CT) slice were segmented according to marks provided by the radiologists. After down sampling and rotating we acquired 174412 samples with 52 by 52 pixel each and the corresponding truth files. Three deep learning algorithms were designed and implemented, including Convolutional Neural Network (CNN), Deep Belief Networks (DBNs), Stacked Denoising Autoencoder (SDAE). To compare the performance of deep learning algorithms with traditional computer aided diagnosis (CADx) system, we designed a scheme with 28 image features and support vector machine. The accuracies of CNN, DBNs, and SDAE are 0.7976, 0.8119, and 0.7929, respectively; the accuracy of our designed traditional CADx is 0.7940, which is slightly lower than CNN and DBNs. We also noticed that the mislabeled nodules using DBNs are 4% larger than using traditional CADx, this might be resulting from down sampling process lost some size information of the nodules.

  7. A digital patient for computer-aided prosthesis design

    PubMed Central

    Colombo, Giorgio; Facoetti, Giancarlo; Rizzi, Caterina

    2013-01-01

    This article concerns the design of lower limb prosthesis, both below and above knee. It describes a new computer-based design framework and a digital model of the patient around which the prosthesis is designed and tested in a completely virtual environment. The virtual model of the patient is the backbone of the whole system, and it is based on a biomechanical general-purpose model customized with the patient's characteristics (e.g. anthropometric measures). The software platform adopts computer-aided and knowledge-guided approaches with the goal of replacing the current development process, mainly hand made, with a virtual one. It provides the prosthetics with a set of tools to design, configure and test the prosthesis and comprehends two main environments: the prosthesis modelling laboratory and the virtual testing laboratory. The first permits the three-dimensional model of the prosthesis to be configured and generated, while the second allows the prosthetics to virtually set up the artificial leg and simulate the patient's postures and movements, validating its functionality and configuration. General architecture and modelling/simulation tools for the platform are described as well as main aspects and results of the experimentation. PMID:24427528

  8. A survey on computer aided diagnosis for ocular diseases

    PubMed Central

    2014-01-01

    Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough. PMID:25175552

  9. Bone tissue engineering scaffolding: computer-aided scaffolding techniques.

    PubMed

    Thavornyutikarn, Boonlom; Chantarapanich, Nattapon; Sitthiseripratip, Kriskrai; Thouas, George A; Chen, Qizhi

    Tissue engineering is essentially a technique for imitating nature. Natural tissues consist of three components: cells, signalling systems (e.g. growth factors) and extracellular matrix (ECM). The ECM forms a scaffold for its cells. Hence, the engineered tissue construct is an artificial scaffold populated with living cells and signalling molecules. A huge effort has been invested in bone tissue engineering, in which a highly porous scaffold plays a critical role in guiding bone and vascular tissue growth and regeneration in three dimensions. In the last two decades, numerous scaffolding techniques have been developed to fabricate highly interconnective, porous scaffolds for bone tissue engineering applications. This review provides an update on the progress of foaming technology of biomaterials, with a special attention being focused on computer-aided manufacturing (Andrade et al. 2002) techniques. This article starts with a brief introduction of tissue engineering (Bone tissue engineering and scaffolds) and scaffolding materials (Biomaterials used in bone tissue engineering). After a brief reviews on conventional scaffolding techniques (Conventional scaffolding techniques), a number of CAM techniques are reviewed in great detail. For each technique, the structure and mechanical integrity of fabricated scaffolds are discussed in detail. Finally, the advantaged and disadvantage of these techniques are compared (Comparison of scaffolding techniques) and summarised (Summary).

  10. Quantitative analysis of ultrasound images for computer-aided diagnosis

    PubMed Central

    Wu, Jie Ying; Tuomi, Adam; Beland, Michael D.; Konrad, Joseph; Glidden, David; Grand, David; Merck, Derek

    2016-01-01

    Abstract. We propose an adaptable framework for analyzing ultrasound (US) images quantitatively to provide computer-aided diagnosis using machine learning. Our preliminary clinical targets are hepatic steatosis, adenomyosis, and craniosynostosis. For steatosis and adenomyosis, we collected US studies from 288 and 88 patients, respectively, as well as their biopsy or magnetic resonanceconfirmed diagnosis. Radiologists identified a region of interest (ROI) on each image. We filtered the US images for various texture responses and use the pixel intensity distribution within each ROI as feature parameterizations. Our craniosynostosis dataset consisted of 22 CT-confirmed cases and 22 age-matched controls. One physician manually measured the vectors from the center of the skull to the outer cortex at every 10 deg for each image and we used the principal directions as shape features for parameterization. These parameters and the known diagnosis were used to train classifiers. Testing with cross-validation, we obtained 72.74% accuracy and 0.71 area under receiver operating characteristics curve for steatosis (p<0.0001), 77.27% and 0.77 for adenomyosis (p<0.0001), and 88.63% and 0.89 for craniosynostosis (p=0.0006). Our framework is able to detect a variety of diseases with high accuracy. We hope to include it as a routinely available support system in the clinic. PMID:26835502

  11. Formal design methods for reliable computer-aided diagnosis: a review.

    PubMed

    Faust, Oliver; Acharya, U Rajendra; Tamura, Toshiyo

    2012-01-01

    Physiological signals, medical images, and biosystems can be used to access the health of a subject and they can support clinicians by improving the diagnosis for treatment purposes. Computer-aided diagnosis (CAD) in healthcare applications can help in automated decision making, visualization and extraction of hidden complex features to aid in the clinical diagnosis. These CAD systems focus on improving the quality of patient care with a minimum of fault due to device failures. In this paper, we argue that a formal and model driven design methodology can lead to systems which meet this requirement. Modeling is not new to CAD, but modeling for systems design is less explored. Therefore, we discuss selected systems design techniques and provide a more concrete design example on computer-aided diagnosis and automated decision making.

  12. Analysis of energy-saving dispatch based on energy efficiency for power system with large scale wind power integration

    NASA Astrophysics Data System (ADS)

    Zou, Lanqing; Zhou, Peng; Li, Shitong; Lin, Li

    2017-01-01

    With the increasing of wind generators and the scale of wind farm, the utilization rate of wind power decreases continually, it is essential to develop an energy-saving dispatching model for the purpose of energy conservation and emission reduction. Firstly, considering some main factors, such as generator operating costs, start-up unit costs, shutdown unit costs, oil consumption and pollutant emission, establish an energy efficiency model. Then, based on the principle of energy-saving dispatch, a model is established which objective is maximizing the energy efficiency. Moreover, in order to realize the priority dispatching of wind power, another model is established which objective is minimizing the wind power shedding. Finally, under the conditions of different installed wind power capacities being integrated into a real region grid, two models are compared and analyzed from perspectives of the society, thermal power enterprise and wind power enterprise.

  13. PCACE-Personal-Computer-Aided Cabling Engineering

    NASA Technical Reports Server (NTRS)

    Billitti, Joseph W.

    1987-01-01

    PCACE computer program developed to provide inexpensive, interactive system for learning and using engineering approach to interconnection systems. Basically database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. Directly emulates typical manual engineering methods of handling data, thus making interface between user and program very natural. Apple version written in P-Code Pascal and IBM PC version of PCACE written in TURBO Pascal 3.0

  14. Intelligent computer-aided instruction in statics

    SciTech Connect

    Richardson, R.C.

    1986-01-01

    An expert system was developed to model the problem solving knowledge of Dr. J.L. Meriam from his text Engineering Mechanics Volume I, Statics. The rules of heuristics for solving two-dimensional truss problems were then implemented in the MRS language. The expert system was then validated by solving problems from the text in the same manner as Meriam. Linked to the expert system were three learning-style modules. The learning styles modeled in this study were drill-and-practice, learning-by-example, and a new style called buddy-study. The buddy-state learning style represents an implementation of the Whimbley-pairs technique for computer-based learning. The learning system comprising the expert system, learning-style modules, and associated support programs were then tested for correctness and completeness. Results of the expert system validation demonstrated a system capable of solving problems within the domain as Meriam did. The learning-style module testing showed procedures commensurate with accepted classroom uses of the styles. The buddy-study method demonstrated a computer-learning strategy that places the expert system and the student user as colleagues in a problem-solving environment.

  15. General purpose architecture for intelligent computer-aided training

    NASA Technical Reports Server (NTRS)

    Loftin, R. Bowen (Inventor); Wang, Lui (Inventor); Baffes, Paul T. (Inventor); Hua, Grace C. (Inventor)

    1994-01-01

    An intelligent computer-aided training system having a general modular architecture is provided for use in a wide variety of training tasks and environments. It is comprised of a user interface which permits the trainee to access the same information available in the task environment and serves as a means for the trainee to assert actions to the system; a domain expert which is sufficiently intelligent to use the same information available to the trainee and carry out the task assigned to the trainee; a training session manager for examining the assertions made by the domain expert and by the trainee for evaluating such trainee assertions and providing guidance to the trainee which are appropriate to his acquired skill level; a trainee model which contains a history of the trainee interactions with the system together with summary evaluative data; an intelligent training scenario generator for designing increasingly complex training exercises based on the current skill level contained in the trainee model and on any weaknesses or deficiencies that the trainee has exhibited in previous interactions; and a blackboard that provides a common fact base for communication between the other components of the system. Preferably, the domain expert contains a list of 'mal-rules' which typifies errors that are usually made by novice trainees. Also preferably, the training session manager comprises an intelligent error detection means and an intelligent error handling means. The present invention utilizes a rule-based language having a control structure whereby a specific message passing protocol is utilized with respect to tasks which are procedural or step-by-step in structure. The rules can be activated by the trainee in any order to reach the solution by any valid or correct path.

  16. Effectiveness of computer aided detection for solitary pulmonary nodules

    NASA Astrophysics Data System (ADS)

    Yan, Jiayong; Li, Wenjie; Du, Xiangying; Lu, Huihai; Xu, Jianrong; Xu, Mantao; Rong, Dongdong

    2009-02-01

    This study is to investigate the incremental effect of using a high performance computer-aided detection (CAD) system in detection of solitary pulmonary nodules in chest radiographs. The Kodak Chest CAD system was evaluated by a panel of six radiologists at different levels of experience. The observer study consisted of two independent phases: readings without CAD and readings with assistance of CAD. The study was conducted over a set of chest radiographs comprising 150 cancer cases and 150 cancer-free cases. The actual sensitivity of the CAD system is 72% with 3.7 false positives per case. Receiver operating characteristic (ROC) analysis was used to assess the overall observer performance. The AUZ (area under ROC curve) showed a significantly improvement (P=0.0001) from 0.844 to 0.884 after using CAD. The ROC analysis was also applied for observer performances on nodules in different sizes and visibilities. The average AUZs are improved from 0.798 to 0.835 (P=0.0003) for 5-10mm nodules, 0.853 to 0.907 (P=0.001) for 10-15mm nodules, 0.864 to 0.897 (P=0.051) for 15-20 mm nodules and 0.859 to 0.896 (P=0.0342) for 20-30mm nodules, respectively. For different visibilities, the average AUZs are improved from 0.886 to 0.915 (P=0.0337), 0.803 to 0.840 (P=0.063), 0.830 to 0.893 (P=0.0001), and 0.813 to 0.847 (P=0.152), for nodules clearly visible, hidden by ribs, partially overlap with ribs, and overlap with other structures, respectively. These results showed that observer performance could be greatly improved when the CAD system is employed as a second reader, especially for small nodules and nodules occluded by ribs.

  17. Computer-aided quantitative bone scan assessment of prostate cancer treatment response

    PubMed Central

    Brown, Matthew S.; Chu, Gregory H.; Kim, Hyun J.; Allen-Auerbach, Martin; Poon, Cheryce; Bridges, Juliette; Vidovic, Adria; Ramakrishna, Bharath; Ho, Judy; Morris, Michael J.; Larson, Steven M.; Scher, Howard I.; Goldin, Jonathan G.

    2012-01-01

    Objective The development and evaluation of a computer-aided bone scan analysis technique to quantify changes in tumor burden and assess treatment effects in prostate cancer clinical trials. Methods We have developed and report on a commercial fully automated computer-aided detection system. Using this system, scan images were intensity normalized, then lesions identified and segmented by anatomic region-specific intensity thresholding. Detected lesions were compared against expert markings to assess the accuracy of the computer-aided detection system. The metrics Bone Scan Lesion Area, Bone Scan Lesion Intensity, and Bone Scan Lesion Count were calculated from identified lesions, and their utility in assessing treatment effects was evaluated by analyzing before and after scans from metastatic castration-resistant prostate cancer patients: 10 treated and 10 untreated. In this study, patients were treated with cabozantinib, a MET/VEGF inhibitor resulting in high rates of resolution of bone scan abnormalities. Results Our automated computer-aided detection system identified bone lesion pixels with 94% sensitivity, 89% specificity, and 89% accuracy. Significant differences in changes from baseline were found between treated and untreated groups in all assessed measurements derived by our system. The most significant measure, Bone Scan Lesion Area, showed a median (interquartile range) change from baseline at week 6 of 7.13% (27.61) in the untreated group compared with −73.76% (45.38) in the cabozantinib-treated group (P = 0.0003). Conclusions Our system accurately and objectively identified and quantified metastases in bone scans, allowing for interpatient and intrapatient comparison. It demonstrates potential as an objective measurement of treatment effects, laying the foundation for validation against other clinically relevant outcome measures. PMID:22367858

  18. On the convergence of nanotechnology and Big Data analysis for computer-aided diagnosis.

    PubMed

    Rodrigues, Jose F; Paulovich, Fernando V; de Oliveira, Maria Cf; de Oliveira, Osvaldo N

    2016-04-01

    An overview is provided of the challenges involved in building computer-aided diagnosis systems capable of precise medical diagnostics based on integration and interpretation of data from different sources and formats. The availability of massive amounts of data and computational methods associated with the Big Data paradigm has brought hope that such systems may soon be available in routine clinical practices, which is not the case today. We focus on visual and machine learning analysis of medical data acquired with varied nanotech-based techniques and on methods for Big Data infrastructure. Because diagnosis is essentially a classification task, we address the machine learning techniques with supervised and unsupervised classification, making a critical assessment of the progress already made in the medical field and the prospects for the near future. We also advocate that successful computer-aided diagnosis requires a merge of methods and concepts from nanotechnology and Big Data analysis.

  19. Research on computer aided testing of pilot response to critical in-flight events

    NASA Technical Reports Server (NTRS)

    Giffin, W. C.; Rockwell, T. H.; Smith, P. J.

    1984-01-01

    Experiments on pilot decision making are described. The development of models of pilot decision making in critical in flight events (CIFE) are emphasized. The following tests are reported on the development of: (1) a frame system representation describing how pilots use their knowledge in a fault diagnosis task; (2) assessment of script norms, distance measures, and Markov models developed from computer aided testing (CAT) data; and (3) performance ranking of subject data. It is demonstrated that interactive computer aided testing either by touch CRT's or personal computers is a useful research and training device for measuring pilot information management in diagnosing system failures in simulated flight situations. Performance is dictated by knowledge of aircraft sybsystems, initial pilot structuring of the failure symptoms and efficient testing of plausible causal hypotheses.

  20. Program for computer aided reliability estimation

    NASA Technical Reports Server (NTRS)

    Mathur, F. P. (Inventor)

    1972-01-01

    A computer program for estimating the reliability of self-repair and fault-tolerant systems with respect to selected system and mission parameters is presented. The computer program is capable of operation in an interactive conversational mode as well as in a batch mode and is characterized by maintenance of several general equations representative of basic redundancy schemes in an equation repository. Selected reliability functions applicable to any mathematical model formulated with the general equations, used singly or in combination with each other, are separately stored. One or more system and/or mission parameters may be designated as a variable. Data in the form of values for selected reliability functions is generated in a tabular or graphic format for each formulated model.

  1. The Rise of Computer-Aided Discovery in Geoscience

    NASA Astrophysics Data System (ADS)

    Pankratius, V.; Blair, D. M.; Gowanlock, M.; Lind, F. D.; Erickson, P. J.

    2015-12-01

    Next-generation Geoscience will need to handle rapidly growing data volumes and exploration of complex phenomena challenging human cognitive limits. With instruments digitizing large amounts of sensor data from many sources, the scientific discovery process becomes a large-scale search process. However, insight generation is still a key problem and is especially complex in Geoscience, particularly when exploratory studies involve fusion of large data from various instruments in a manual labor-intensive manner. We propose an approach for a computer-aided discovery infrastructure that automatically explores the connection between physics models and empirical data to accelerate the pace of new discoveries. The approach uses (1) A system engaging scientists to programmatically express hypothesized Geoscience scenarios, constraints, and model variations, so as to automatically explore and evaluate the combinatorial search space of possible explanations in parallel on a variety of data sets. This automated system employs machine learning to support algorithmic choice and workflow reconfiguration allowing systematic pruning of the search space of applied algorithms and parameters based on historical results. (2) A cloud-based environment allowing scientists to conduct powerful exploratory analyses on large data sets that reside in data centers. Various search modes are provided, including a mode where scientists can iteratively guide the search based on intermediate results. This functionality directs the system to identify more Geospace features that are analogous or related in various ways. (3) Scientist input is used to configure programmable crawlers that automate and scale the search for interesting phenomena on cloud-based infrastructures. We discuss various application scenarios to show the impact of workflow configuration on scientific feature detection. Acknowledgements. We acknowledge support from NSF ACI-1442997 and NASA AIST NNX15AG84G (PI: V. Pankratius).

  2. Application of infrared thermography in computer aided diagnosis

    NASA Astrophysics Data System (ADS)

    Faust, Oliver; Rajendra Acharya, U.; Ng, E. Y. K.; Hong, Tan Jen; Yu, Wenwei

    2014-09-01

    The invention of thermography, in the 1950s, posed a formidable problem to the research community: What is the relationship between disease and heat radiation captured with Infrared (IR) cameras? The research community responded with a continuous effort to find this crucial relationship. This effort was aided by advances in processing techniques, improved sensitivity and spatial resolution of thermal sensors. However, despite this progress fundamental issues with this imaging modality still remain. The main problem is that the link between disease and heat radiation is complex and in many cases even non-linear. Furthermore, the change in heat radiation as well as the change in radiation pattern, which indicate disease, is minute. On a technical level, this poses high requirements on image capturing and processing. On a more abstract level, these problems lead to inter-observer variability and on an even more abstract level they lead to a lack of trust in this imaging modality. In this review, we adopt the position that these problems can only be solved through a strict application of scientific principles and objective performance assessment. Computing machinery is inherently objective; this helps us to apply scientific principles in a transparent way and to assess the performance results. As a consequence, we aim to promote thermography based Computer-Aided Diagnosis (CAD) systems. Another benefit of CAD systems comes from the fact that the diagnostic accuracy is linked to the capability of the computing machinery and, in general, computers become ever more potent. We predict that a pervasive application of computers and networking technology in medicine will help us to overcome the shortcomings of any single imaging modality and this will pave the way for integrated health care systems which maximize the quality of patient care.

  3. Computer-aided ionogram reduction: Software structure

    NASA Astrophysics Data System (ADS)

    Emeljanov, G. M.; Zukovsky, I. U.; Smirnov, N. I.

    Special software has been developed in view of an automated ionogram reduction and statistical handling of relevant data. Requirement for such software are formulated and possible ways to satisfy these are shown. Distinguishing different levels, a detailed description of system levels and terminal maintenance is given. Much attention is paid to the different needs for tabular data output by interactive control; the function of application modules is checked. The user is provided with simple and effective means for checking the system operation at different levels.

  4. Evaluation and Assessment of a Biomechanics Computer-Aided Instruction.

    ERIC Educational Resources Information Center

    Washington, N.; Parnianpour, M.; Fraser, J. M.

    1999-01-01

    Describes the Biomechanics Tutorial, a computer-aided instructional tool that was developed at Ohio State University to expedite the transition from lecture to application for undergraduate students. Reports evaluation results that used statistical analyses and student questionnaires to show improved performance on posttests as well as positive…

  5. National Survey of Computer Aided Manufacturing in Industrial Technology Programs.

    ERIC Educational Resources Information Center

    Heidari, Farzin

    The current status of computer-aided manufacturing in the 4-year industrial technology programs in the United States was studied. All industrial technology department chairs were mailed a questionnaire divided into program information, equipment information, and general comments sections. The questionnaire was designed to determine the subjects…

  6. Research in Computer-Aided Performance Training. Final Report.

    ERIC Educational Resources Information Center

    Rigney, Joseph W.; Towne, Douglas M.

    The principal emphasis of this three-year research program was on developing better ways to utilize the power of the digital computer in computer-aided performance training. Two large programs, collectively called TASKTEACH, were developed and tested. These programs combined simulation and gaming techniques. The dialog with the student is…

  7. De novo computer-aided design of novel antiviral agents.

    PubMed

    Massarotti, Alberto; Coluccia, Antonio; Sorba, Giovanni; Silvestri, Romano; Brancale, Andrea

    2012-01-01

    Computer-aided drug design techniques have become an integral part of the drug discovery process. In particular, de novo methodologies can be useful to identify putative ligands for a specific target relying only on the structural information of the target itself. Here we discuss the basic de novo approaches available and their application in antiviral drug design.:

  8. How Effective Is Feedback in Computer-Aided Assessments?

    ERIC Educational Resources Information Center

    Gill, Mundeep; Greenhow, Martin

    2008-01-01

    Computer-Aided Assessments (CAAs) have been used increasingly at Brunel University for over 10 years to test students' mathematical abilities. Recently, we have focussed on providing very rich feedback to the students; given the work involved in designing and coding such feedback, it is important to study the impact of the interaction between…

  9. Computer Aided Evaluation of Higher Education Tutors' Performance

    ERIC Educational Resources Information Center

    Xenos, Michalis; Papadopoulos, Thanos

    2007-01-01

    This article presents a method for computer-aided tutor evaluation: Bayesian Networks are used for organizing the collected data about tutors and for enabling accurate estimations and predictions about future tutor behavior. The model provides indications about each tutor's strengths and weaknesses, which enables the evaluator to exploit strengths…

  10. Does Computer-Aided Formative Assessment Improve Learning Outcomes?

    ERIC Educational Resources Information Center

    Hannah, John; James, Alex; Williams, Phillipa

    2014-01-01

    Two first-year engineering mathematics courses used computer-aided assessment (CAA) to provide students with opportunities for formative assessment via a series of weekly quizzes. Most students used the assessment until they achieved very high (>90%) quiz scores. Although there is a positive correlation between these quiz marks and the final…

  11. COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS

    EPA Science Inventory

    The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...

  12. WINCADRE INORGANIC (WINDOWS COMPUTER-AIDED DATA REVIEW AND EVALUATION)

    EPA Science Inventory

    WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed in...

  13. WINCADRE (COMPUTER-AIDED DATA REVIEW AND EVALUATION)

    EPA Science Inventory

    WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed ...

  14. Special Computer Aided Education Using Multimedia.

    ERIC Educational Resources Information Center

    San, Lei Chu; Hong, Io Hio

    1998-01-01

    Discusses the use of computer-assisted instruction with multimedia for people with disabilities. Considers the needs of children with disabilities and learning difficulties, and presents an example of a voice-assistant system for blind people. Further applications are also discussed. (LRW)

  15. TARGET: Research in Computer Aids for Translators.

    ERIC Educational Resources Information Center

    McCracken, Donald; Strazds, Andris E.

    1980-01-01

    Reviews the background of the "TARGET Project for Aids to Translation," its current facilities, and its goals. Describes the system's central feature as an interactive, multilingual terminology database intended to eliminate time wasted in researching unknown terms and to facilitate final document production, study of person-machine…

  16. Computer aided detection of endobronchial valves

    NASA Astrophysics Data System (ADS)

    Ochs, Robert A.; Goldin, Jonathan G.; Abtin, Fereidoun; Ghurabi, Raffi; Rao, Ajay; Ahmad, Shama; da Costa, Irene; Brown, Matthew

    2008-03-01

    The ability to automatically detect and monitor implanted devices may serve an important role in patient care and the evaluation of device and treatment efficacy. The purpose of this research was to develop a system for the automated detection of one-way endobronchial valves implanted as part of a clinical trial for less invasive lung volume reduction. Volumetric thin section CT data was obtained for 275 subjects; 95 subjects implanted with 246 devices were used for system development and 180 subjects implanted with 354 devices were reserved for testing. The detection process consisted of pre-processing, pattern-recognition based detection, and a final device selection. Following the pre-processing, a set of classifiers were trained using AdaBoost to discriminate true devices from false positives (such as calcium deposits). The classifiers in the cascade used simple features (the mean or max attenuation) computed near control points relative to a template model of the valve. Visual confirmation of the system output served as the gold standard. FROC analysis was performed for the evaluation; the system could be set so the mean sensitivity was 96.5% with a mean of 0.18 false positives per subject. These generic device modeling and detection techniques may be applicable to other devices and useful for monitoring the placement and function of implanted devices.

  17. Geometric modeling for computer aided design

    NASA Technical Reports Server (NTRS)

    Schwing, James L.

    1988-01-01

    Research focused on two major areas. The first effort addressed the design and implementation of a technique that allows for the visualization of the real time variation of physical properties. The second effort focused on the design and implementation of an on-line help system with components designed for both authors and users of help information.

  18. Computer Aided Management for Information Processing Projects.

    ERIC Educational Resources Information Center

    Akman, Ibrahim; Kocamustafaogullari, Kemal

    1995-01-01

    Outlines the nature of information processing projects and discusses some project management programming packages. Describes an in-house interface program developed to utilize a selected project management package (TIMELINE) by using Oracle Data Base Management System tools and Pascal programming language for the management of information system…

  19. Computer-Aided Engineering Of Cabling

    NASA Technical Reports Server (NTRS)

    Billitti, Joseph W.

    1989-01-01

    Program generates data sheets, drawings, and other information on electrical connections. DFACS program, centered around single data base, has built-in menus providing easy input of, and access to, data for all personnel involved in system, subsystem, and cabling. Enables parallel design of circuit-data sheets and drawings of harnesses. Also recombines raw information to generate automatically various project documents and drawings, including index of circuit-data sheets, list of electrical-interface circuits, lists of assemblies and equipment, cabling trees, and drawings of cabling electrical interfaces and harnesses. Purpose of program to provide engineering community with centralized data base for putting in, and gaining access to, functional definition of system as specified in terms of details of pin connections of end circuits of subsystems and instruments and data on harnessing. Primary objective to provide instantaneous single point of interchange of information, thus avoiding

  20. Computer-aided software development process design

    NASA Technical Reports Server (NTRS)

    Lin, Chi Y.; Levary, Reuven R.

    1989-01-01

    The authors describe an intelligent tool designed to aid managers of software development projects in planning, managing, and controlling the development process of medium- to large-scale software projects. Its purpose is to reduce uncertainties in the budget, personnel, and schedule planning of software development projects. It is based on dynamic model for the software development and maintenance life-cycle process. This dynamic process is composed of a number of time-varying, interacting developmental phases, each characterized by its intended functions and requirements. System dynamics is used as a modeling methodology. The resulting Software LIfe-Cycle Simulator (SLICS) and the hybrid expert simulation system of which it is a subsystem are described.

  1. Integrating aerodynamic surface modeling for computational fluid dynamics with computer aided structural analysis, design, and manufacturing

    NASA Technical Reports Server (NTRS)

    Thorp, Scott A.

    1992-01-01

    This presentation will discuss the development of a NASA Geometry Exchange Specification for transferring aerodynamic surface geometry between LeRC systems and grid generation software used for computational fluid dynamics research. The proposed specification is based on a subset of the Initial Graphics Exchange Specification (IGES). The presentation will include discussion of how the NASA-IGES standard will accommodate improved computer aided design inspection methods and reverse engineering techniques currently being developed. The presentation is in viewgraph format.

  2. Proceedings of the 1993 Conference on Intelligent Computer-Aided Training and Virtual Environment Technology

    NASA Technical Reports Server (NTRS)

    Hyde, Patricia R.; Loftin, R. Bowen

    1993-01-01

    The volume 2 proceedings from the 1993 Conference on Intelligent Computer-Aided Training and Virtual Environment Technology are presented. Topics discussed include intelligent computer assisted training (ICAT) systems architectures, ICAT educational and medical applications, virtual environment (VE) training and assessment, human factors engineering and VE, ICAT theory and natural language processing, ICAT military applications, VE engineering applications, ICAT knowledge acquisition processes and applications, and ICAT aerospace applications.

  3. Local pulmonary structure classification for computer-aided nodule detection

    NASA Astrophysics Data System (ADS)

    Bahlmann, Claus; Li, Xianlin; Okada, Kazunori

    2006-03-01

    We propose a new method of classifying the local structure types, such as nodules, vessels, and junctions, in thoracic CT scans. This classification is important in the context of computer aided detection (CAD) of lung nodules. The proposed method can be used as a post-process component of any lung CAD system. In such a scenario, the classification results provide an effective means of removing false positives caused by vessels and junctions thus improving overall performance. As main advantage, the proposed solution transforms the complex problem of classifying various 3D topological structures into much simpler 2D data clustering problem, to which more generic and flexible solutions are available in literature, and which is better suited for visualization. Given a nodule candidate, first, our solution robustly fits an anisotropic Gaussian to the data. The resulting Gaussian center and spread parameters are used to affine-normalize the data domain so as to warp the fitted anisotropic ellipsoid into a fixed-size isotropic sphere. We propose an automatic method to extract a 3D spherical manifold, containing the appropriate bounding surface of the target structure. Scale selection is performed by a data driven entropy minimization approach. The manifold is analyzed for high intensity clusters, corresponding to protruding structures. Techniques involve EMclustering with automatic mode number estimation, directional statistics, and hierarchical clustering with a modified Bhattacharyya distance. The estimated number of high intensity clusters explicitly determines the type of pulmonary structures: nodule (0), attached nodule (1), vessel (2), junction (>3). We show accurate classification results for selected examples in thoracic CT scans. This local procedure is more flexible and efficient than current state of the art and will help to improve the accuracy of general lung CAD systems.

  4. Computer-aided pulmonary image analysis in small animal models

    PubMed Central

    Xu, Ziyue; Bagci, Ulas; Mansoor, Awais; Kramer-Marek, Gabriela; Luna, Brian; Kubler, Andre; Dey, Bappaditya; Foster, Brent; Papadakis, Georgios Z.; Camp, Jeremy V.; Jonsson, Colleen B.; Bishai, William R.; Jain, Sanjay; Udupa, Jayaram K.; Mollura, Daniel J.

    2015-01-01

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases. PMID:26133591

  5. Computer-aided pulmonary image analysis in small animal models

    SciTech Connect

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J.; Bagci, Ulas; Kramer-Marek, Gabriela; Luna, Brian; Kubler, Andre; Dey, Bappaditya; Jain, Sanjay; Foster, Brent; Papadakis, Georgios Z.; Camp, Jeremy V.; Jonsson, Colleen B.; Bishai, William R.; Udupa, Jayaram K.

    2015-07-15

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

  6. Computer Aided Conceptual Design of Submarines

    DTIC Science & Technology

    1984-06-01

    many people’s work and support in addition to my own. Mr. Richard Salter, of Computervision Corporation , was instrumental in *2 providing unlimited...McDonnell-Douglas Automation Division, and others. For this thesis, Computervision Corporation , of Bedford, Massachusetts, offered free system time...3t0! Ytl )-RANS 311! XL-XL-LINT 312! 1-1-1 313!UNTILI1.0?. 131) 314!XI 132)-LOlA 31!,!Y( 1321-0 316!IIPENPW ti.-01T.P01lNrS- 3! 7!J-1 31W!REPEAT 310!&X

  7. PCACE- PERSONAL COMPUTER AIDED CABLING ENGINEERING

    NASA Technical Reports Server (NTRS)

    Billitti, J. W.

    1994-01-01

    A computerized interactive harness engineering program has been developed to provide an inexpensive, interactive system which is designed for learning and using an engineering approach to interconnection systems. PCACE is basically a database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. This directly emulates the typical manual engineering methods of data handling, thus making the user interface to the program very natural. Data files can be created, viewed, manipulated, or printed in real time. The printed ouput is in a form ready for use by fabrication and engineering personnel. PCACE also contains a wide variety of error-checking routines including connector contact checks during hardcopy generation. The user may edit existing harness data files or create new files. In creating a new file, the user is given the opportunity to insert all the connector and harness boiler plate data which would be part of a normal connector wiring diagram. This data includes the following: 1) connector reference designator, 2) connector part number, 3) backshell part number, 4) cable reference designator, 5) cable part number, 6) drawing revision, 7) relevant notes, 8) standard wire gauge, and 9) maximum circuit count. Any item except the maximum circuit count may be left blank, and any item may be changed at a later time. Once a file is created and organized, the user is directed to the main menu and has access to the file boiler plate, the circuit wiring records, and the wiring records index list. The organization of a file is such that record zero contains the connector/cable boiler plate, and all other records contain circuit wiring data. Each wiring record will handle a circuit with as many as nine wires in the interface. The record stores the circuit name and wire count and the following data for each wire: 1) wire identifier, 2) contact, 3) splice, 4) wire gauge if different from standard

  8. Computer aided selection of candidate vaccine antigens

    PubMed Central

    2010-01-01

    Immunoinformatics is an emergent branch of informatics science that long ago pullulated from the tree of knowledge that is bioinformatics. It is a discipline which applies informatic techniques to problems of the immune system. To a great extent, immunoinformatics is typified by epitope prediction methods. It has found disappointingly limited use in the design and discovery of new vaccines, which is an area where proper computational support is generally lacking. Most extant vaccines are not based around isolated epitopes but rather correspond to chemically-treated or attenuated whole pathogens or correspond to individual proteins extract from whole pathogens or correspond to complex carbohydrate. In this chapter we attempt to review what progress there has been in an as-yet-underexplored area of immunoinformatics: the computational discovery of whole protein antigens. The effective development of antigen prediction methods would significantly reduce the laboratory resource required to identify pathogenic proteins as candidate subunit vaccines. We begin our review by placing antigen prediction firmly into context, exploring the role of reverse vaccinology in the design and discovery of vaccines. We also highlight several competing yet ultimately complementary methodological approaches: sub-cellular location prediction, identifying antigens using sequence similarity, and the use of sophisticated statistical approaches for predicting the probability of antigen characteristics. We end by exploring how a systems immunomics approach to the prediction of immunogenicity would prove helpful in the prediction of antigens. PMID:21067543

  9. A Computer-Aided Distinction Method of Borderline Grades of Oral Cancer

    NASA Astrophysics Data System (ADS)

    Sami, Mustafa M.; Saito, Masahisa; Muramatsu, Shogo; Kikuchi, Hisakazu; Saku, Takashi

    We have developed a new computer-aided diagnostic system for differentiating oral borderline malignancies in hematoxylin-eosin stained microscopic images. Epithelial dysplasia and carcinoma in-situ (CIS) of oral mucosa are two different borderline grades similar to each other, and it is difficult to distinguish between them. A new image processing and analysis method has been applied to a variety of histopathological features and shows the possibility for differentiating the oral cancer borderline grades automatically. The method is based on comparing the drop-shape similarity level in a particular manually selected pair of neighboring rete ridges. It was found that the considered similarity level in dysplasia was higher than those in epithelial CIS, of which pathological diagnoses were conventionally made by pathologists. The developed image processing method showed a good promise for the computer-aided pathological assessment of oral borderline malignancy differentiation in clinical practice.

  10. Freedom and necessity in computer aided composition: A thinking framework and its application

    NASA Astrophysics Data System (ADS)

    Kretz, Johannes

    This paper presents some of the author's experiences with computer aided composition (CAC): the modeling of physical movements is used to obtain plausible musical gestures in interaction with constraint programming (rule based expert systems) in order to achieve precisely structured, consistent musical material with strong inner logic and syntax in pitch material. The "Constraints Engine" by Michael Laurson implemented in OpenMusic (IRCAM) or PWGL (Sibelius Academy) can be used to set up an interactive framework for composition, which offers a balance of freedom (allowing chance operations and arbitrary decisions of the composer) and necessity (through strict rules as well as through criteria for optimization). Computer Aided Composition is moving far beyond being "algorithmic" or "mechanical". This paper proposes an approach based on evolutionary epistemology (by the Austrian biologist and philosopher Rupert Riedl). The aim is a holistic synthesis of artistic freedom and coherent structures similar to the grown order of nature.

  11. Computer-aided analysis and design of the shape rolling process for producing turbine engine airfoils

    NASA Technical Reports Server (NTRS)

    Lahoti, G. D.; Akgerman, N.; Altan, T.

    1978-01-01

    Mild steel (AISI 1018) was selected as model cold rolling material and Ti-6A1-4V and Inconel 718 were selected as typical hot rolling and cold rolling alloys, respectively. The flow stress and workability of these alloys were characterized and friction factor at the roll/workpiece interface was determined at their respective working conditions by conducting ring tests. Computer-aided mathematical models for predicting metal flow and stresses, and for simulating the shape rolling process were developed. These models utilized the upper bound and the slab methods of analysis, and were capable of predicting the lateral spread, roll separating force, roll torque, and local stresses, strains and strain rates. This computer-aided design system was also capable of simulating the actual rolling process, and thereby designing the roll pass schedule in rolling of an airfoil or a similar shape.

  12. Computer-aided diagnosis and artificial intelligence in clinical imaging.

    PubMed

    Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio

    2011-11-01

    Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and

  13. Computer-Aided Construction of Chemical Kinetic Models

    SciTech Connect

    Green, William H.

    2014-12-31

    The combustion chemistry of even simple fuels can be extremely complex, involving hundreds or thousands of kinetically significant species. The most reasonable way to deal with this complexity is to use a computer not only to numerically solve the kinetic model, but also to construct the kinetic model in the first place. Because these large models contain so many numerical parameters (e.g. rate coefficients, thermochemistry) one never has sufficient data to uniquely determine them all experimentally. Instead one must work in “predictive” mode, using theoretical rather than experimental values for many of the numbers in the model, and as appropriate refining the most sensitive numbers through experiments. Predictive chemical kinetics is exactly what is needed for computer-aided design of combustion systems based on proposed alternative fuels, particularly for early assessment of the value and viability of proposed new fuels before those fuels are commercially available. This project was aimed at making accurate predictive chemical kinetics practical; this is a challenging goal which requires a range of science advances. The project spanned a wide range from quantum chemical calculations on individual molecules and elementary-step reactions, through the development of improved rate/thermo calculation procedures, the creation of algorithms and software for constructing and solving kinetic simulations, the invention of methods for model-reduction while maintaining error control, and finally comparisons with experiment. Many of the parameters in the models were derived from quantum chemistry calculations, and the models were compared with experimental data measured in our lab or in collaboration with others.

  14. Computer-Aided Design and Computer-Aided Manufacturing Hydroxyapatite/Epoxide Acrylate Maleic Compound Construction for Craniomaxillofacial Bone Defects.

    PubMed

    Zhang, Lei; Shen, Shunyao; Yu, Hongbo; Shen, Steve Guofang; Wang, Xudong

    2015-07-01

    The aim of this study was to investigate the use of computer-aided design and computer-aided manufacturing hydroxyapatite (HA)/epoxide acrylate maleic (EAM) compound construction artificial implants for craniomaxillofacial bone defects. Computed tomography, computer-aided design/computer-aided manufacturing and three-dimensional reconstruction, as well as rapid prototyping were performed in 12 patients between 2008 and 2013. The customized HA/EAM compound artificial implants were manufactured through selective laser sintering using a rapid prototyping machine into the exact geometric shapes of the defect. The HA/EAM compound artificial implants were then implanted during surgical reconstruction. Color-coded superimpositions demonstrated the discrepancy between the virtual plan and achieved results using Geomagic Studio. As a result, the HA/EAM compound artificial bone implants were perfectly matched with the facial areas that needed reconstruction. The postoperative aesthetic and functional results were satisfactory. The color-coded superimpositions demonstrated good consistency between the virtual plan and achieved results. The three-dimensional maximum deviation is 2.12 ± 0.65  mm and the three-dimensional mean deviation is 0.27 ± 0.07  mm. No facial nerve weakness or pain was observed at the follow-up examinations. Only 1 implant had to be removed 2 months after the surgery owing to severe local infection. No other complication was noted during the follow-up period. In conclusion, computer-aided, individually fabricated HA/EAM compound construction artificial implant was a good craniomaxillofacial surgical technique that yielded improved aesthetic results and functional recovery after reconstruction.

  15. Dispatchability Maximization for Co-Optimized Energy and Reserve Dispatch With Explicit Reliability Guarantee

    SciTech Connect

    Wei, Wei; Wang, Jianhui; Mei, Shengwei

    2016-09-23

    In this paper, we consider dispatchability as the set of all admissible nodal wind power injections that will not cause infeasibility in real-time dispatch (RTD). Our work reveals that the dispatchability of the affine policy based RTD (AF-RTD) is a polytope whose coefficients are linear functions of the generation schedule and the gain matrix of affine policy. Two mathematical formulations of the dispatchability maximized energy and reserve dispatch (DM-ERD) are proposed. The first one maximizes the distance from the forecast to the boundaries of the dispatchability polytope subject to the available production cost or reserve cost. Provided the forecast value and variance of wind power, the generalized Gauss inequality (GGI) is adopted to evaluate the probability of infeasible RTD without the exact probability distribution of wind power. Combining the first formulation and the GGI approach, the second one minimizes the total cost subject to a desired reliability level through dispatchability maximization. Efficient convex optimization based algorithms are developed to solve these two models. Different from the conventional robust optimization method, our model does not rely on the specific uncertainty set of wind generation and directly optimizes the uncertainty accommodation capability of the power system. The proposed method is also compared with the affine policy based robust energy and reserve dispatch (AR-ERD). Case studies on the PJM 5-bus system illustrate the proposed concept and method. Experiments on the IEEE 118-bus system demonstrate the applicability of our method on moderate sized systems and its scalability to large dimensional uncertainty.

  16. Emergency medical dispatch.

    PubMed

    Dunford, James V

    2002-11-01

    EMD will always remain somewhat of an imprecise science by nature. 911 is, after all, the access point for lifesaving assistance, and citizens must have absolute freedom to this service. The consequence of having the freedom to request help from any location at any time is that some individuals will use it for the wrong reasons. Present-day dispatchers must serve ever-broadening communities with multiple languages, cultural diversity, and unique health needs. Along with other essential personnel that make up the fabric of the public safety net, emergency medical dispatchers have now become essential to the provision of time-critical skills and compassion for perceived medical emergency.

  17. Microgrid management architecture considering optimal battery dispatch

    NASA Astrophysics Data System (ADS)

    Paul, Tim George

    Energy management and economic operation of microgrids with energy storage systems at the distribution level have attracted significant research interest in recent years. One of the challenges in this area has been the coordination of energy management functions with decentralized and centralized dispatch. In this thesis a distributed dispatch algorithm for a microgrid consisting of a photovoltaic source with energy storage which can work with a centralized dispatch algorithm that ensure stability of the microgrid is proposed. To this end, first a rule based dispatch algorithm is formulated which is based on maximum resource utilization and can work in both off grid and grid connected mode. Then a fixed horizon optimization algorithm which minimizes the cost of power taken from the grid is developed. In order to schedule the battery based on changes in the PV farm a predictive horizon methodology based optimization is designed. Further, the rule based and optimization based dispatch methodologies is linked to optimize the voltage deviations at the microgrid Point of Common Coupling (PCC). The main advantage of the proposed method is that, an optimal active power dispatch considering the nominal voltage bandwidth can be initiated for the microgrid in both grid connected or off grid mode of operation. Also, the method allows the grid operator to consider cost based optimal renewable generation scheduling and/or the maximum power extraction based modes of operation simultaneously or separately based on grid operating conditions and topologies. Further, the methods allows maintaining PCC voltage within the limits during these modes of operation and at the same time ensure that the battery dispatch is optimal.

  18. Development of a computer-aided procedure for the national program of inspection of dams

    NASA Technical Reports Server (NTRS)

    1973-01-01

    An effort was undertaken to determine the utility of ERTS-1 MSS data, together with automatic data processing (ADP) techniques, to detect and locate surface water, and transfer the related technology to the Texas Water Rights Commission (TWRC). A test site was selected, ERTS-1 MSS and ancillary data obtained, and existent ADP classification programs applied. During the course of this effort a linear discriminant function was developed. The results were evaluated for potential candidates for a transferable procedure. A computer-aided technique using a linear discriminant function was selected and recommended, for inclusion in an operational system, which met detection and location criteria. Specifically, evaluation of the selected computer-aided procedure for the test site resulted in the detection of 100 percent of areas of surface water 10 acres or greater in areal extent and the geographic location of areas classified as water to a positional accuracy of 1000 feet or closer. The procedure was recommended for inclusion in an operational computer-aided procedure for transfer to TWRC.

  19. Resource Planning Model: An Integrated Resource Planning and Dispatch Tool for Regional Electric Systems

    SciTech Connect

    Mai, T.; Drury, E.; Eurek, K.; Bodington, N.; Lopez, A.; Perry, A.

    2013-01-01

    This report introduces a new capacity expansion model, the Resource Planning Model (RPM), with high spatial and temporal resolution that can be used for mid- and long-term scenario planning of regional power systems. Although RPM can be adapted to any geographic region, the report describes an initial version of the model adapted for the power system in Colorado. It presents examples of scenario results from the first version of the model, including an example of a 30%-by-2020 renewable electricity penetration scenario.

  20. Systematic Evaluation of Stochastic Methods in Power System Scheduling and Dispatch with Renewable Energy

    SciTech Connect

    Wang, Yishen; Zhou, Zhi; Liu, Cong; Botterud, Audun

    2016-08-01

    As more wind power and other renewable resources are being integrated into the electric power grid, the forecast uncertainty brings operational challenges for the power system operators. In this report, different operational strategies for uncertainty management are presented and evaluated. A comprehensive and consistent simulation framework is developed to analyze the performance of different reserve policies and scheduling techniques under uncertainty in wind power. Numerical simulations are conducted on a modified version of the IEEE 118-bus system with a 20% wind penetration level, comparing deterministic, interval, and stochastic unit commitment strategies. The results show that stochastic unit commitment provides a reliable schedule without large increases in operational costs. Moreover, decomposition techniques, such as load shift factor and Benders decomposition, can help in overcoming the computational obstacles to stochastic unit commitment and enable the use of a larger scenario set to represent forecast uncertainty. In contrast, deterministic and interval unit commitment tend to give higher system costs as more reserves are being scheduled to address forecast uncertainty. However, these approaches require a much lower computational effort Choosing a proper lower bound for the forecast uncertainty is important for balancing reliability and system operational cost in deterministic and interval unit commitment. Finally, we find that the introduction of zonal reserve requirements improves reliability, but at the expense of higher operational costs.

  1. Computer-aided surgery: concepts and applications in vascular surgery

    PubMed Central

    Kaladji, Adrien; Lucas, Antoine; Cardon, Alain; Haigron, Pascal

    2012-01-01

    Computer-aided surgery makes use of a variety of technologies and information sources. The challenge over the last ten years has been to apply these methods to tissues that deform, as do vessels when relatively rigid flexible objects are introduced into them (Lunderquist rigid guidewire, aortic prosthesis, etc.) Three stages of computer-aided endovascular surgery are examined: sizing, planning and intra-operative assistance. Our work shows that an approach based on optimized use of the imaging data acquired during the various observation phases (pre and intra-operative), involving only lightweight computer equipment that is relatively transparent for the user, makes it possible to provide useful (i.e. necessary and sufficient) information at the appropriate moment, in order to aid decision-making and enhance the security of endovascular procedures. PMID:22513982

  2. A computer aided teaching course on corrosion of concrete structures

    SciTech Connect

    Ramesht, M.H.; Cottis, R.A.

    1996-10-01

    Computers provide a powerful opportunity for the development of teaching materials. They provide a rich interactive environment to stimulate and engage the student. The advent of computers with multimedia capabilities allows the constructor of teaching materials to show the student material from many sources; text, chart, audio, video, animation, simulation, sound or photographs. When these are combined with interactivity, a powerful learning environment is created. There is currently no CAL (Computer Aided Learning) or CBT (Computer Based Training) material available on the subject of corrosion and corrosion protection in concrete structures for civil engineering students. This paper will describe a Computer Aided Learning package intended to introduce students to the environmental degradation of concrete structures.

  3. Computer-aided design of polymers and composites

    NASA Technical Reports Server (NTRS)

    Kaelble, D. H.

    1985-01-01

    This book on computer-aided design of polymers and composites introduces and discusses the subject from the viewpoint of atomic and molecular models. Thus, the origins of stiffness, strength, extensibility, and fracture toughness in composite materials can be analyzed directly in terms of chemical composition and molecular structure. Aspects of polymer composite reliability are considered along with characterization techniques for composite reliability, relations between atomic and molecular properties, computer aided design and manufacture, polymer CAD/CAM models, and composite CAD/CAM models. Attention is given to multiphase structural adhesives, fibrous composite reliability, metal joint reliability, polymer physical states and transitions, chemical quality assurance, processability testing, cure monitoring and management, nondestructive evaluation (NDE), surface NDE, elementary properties, ionic-covalent bonding, molecular analysis, acid-base interactions, the manufacturing science, and peel mechanics.

  4. Incorporating Wind Generation Forecast Uncertainty into Power System Operation, Dispatch, and Unit Commitment Procedures

    SciTech Connect

    Makarov, Yuri V.; Etingov, Pavel V.; Huang, Zhenyu; Ma, Jian; Subbarao, Krishnappa

    2010-10-19

    In this paper, an approach to evaluate the uncertainties of the balancing capacity, ramping capability, and ramp duration requirements is proposed. The approach includes three steps: forecast data acquisition, statistical analysis of retrospective information, and prediction of grid balancing requirements for a specified time horizon and a given confidence level. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on histogram analysis, incorporating sources of uncertainty of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the "flying-brick" technique is developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation process is used to validate the accuracy of the confidence intervals. To demonstrate the validity of the developed uncertainty assessment methods and its impact on grid operation, a framework for integrating the proposed methods with an EMS system is developed. Demonstration through integration with an EMS system illustrates the applicability of the proposed methodology and the developed tool for actual grid operation and paves the road for integration with EMS systems from other vendors.

  5. VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITEWIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITE-WIDE FIRE ALARM SIGNALS, INCLUDING ALL FIRE PHONES, FIRE PULL BOXES, HEAT AND SMOKE DETECTORS, AND SUPPRESSION SYSTEM FLOW ALARMS, ARE TRANSMITTED TO THE BUILDING 331 DISPATCHER'S OFFICE. (3/77) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO

  6. View west of load dispatch model board; section covers substations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  7. RAMCAD (Reliability, Availability and Maintainability in Computer-Aided Design)

    DTIC Science & Technology

    1992-11-01

    documents the Reliability, Availability, and Maintainability in Computer-Aided Design (RAMCAD) Software Development Program which was started in July 1986 ...by General Dynamics Convair Division under a Program Research and Development Announcement (PRDA 86-16-PMRS). This PRDA was issued on May 15, 1986 ...PRDA 86-16-PMRS) was issued on May 15, 1986 , by the Air Force Human Resources ..aboratory (AFHRL, changed to Armstrong Laboratory, Human Resources

  8. Analysis of Interval Changes on Mammograms for Computer Aided Diagnosis

    DTIC Science & Technology

    2000-05-01

    research groups are in the process of developing computer-aided diagnosis (CAD) methods which can provide a second opinion to the radiologist for the...benign lesions. 3- 8 Knowledge from di- features between current and previous mammograms of the verse areas such as signal and image processing , pattern...December 1999 2673 Sanjay-Gopal et al: A regional registration technique 26732673-p i n- iimages . The 74 temporal image pairs were comprised of 43 Cj

  9. Hardware synthesis from DDL. [Digital Design Language for computer aided design and test of LSI

    NASA Technical Reports Server (NTRS)

    Shah, A. M.; Shiva, S. G.

    1981-01-01

    The details of the digital systems can be conveniently input into the design automation system by means of Hardware Description Languages (HDL). The Computer Aided Design and Test (CADAT) system at NASA MSFC is used for the LSI design. The Digital Design Language (DDL) has been selected as HDL for the CADAT System. DDL translator output can be used for the hardware implementation of the digital design. This paper addresses problems of selecting the standard cells from the CADAT standard cell library to realize the logic implied by the DDL description of the system.

  10. Incorporating Uncertainty of Wind Power Generation Forecast into Power System Operation, Dispatch, and Unit Commitment Procedures

    SciTech Connect

    Makarov, Yuri V.; Etingov, Pavel V.; Ma, Jian; Huang, Zhenyu; Subbarao, Krishnappa

    2011-06-23

    An approach to evaluate the uncertainties of the balancing capacity, ramping capability, and ramp duration requirements is proposed. The approach includes three steps: forecast data acquisition, statistical analysis of retrospective information, and prediction of grid balancing requirements for a specified time horizon and a given confidence level. An assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on histogram analysis, incorporating sources of uncertainty - both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures). A new method called the 'flying-brick' technique is developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation process is used to validate the accuracy of the confidence intervals. To demonstrate the validity of the developed uncertainty assessment methods and its impact on grid operation, a framework for integrating the proposed methods with an EMS system is developed. Demonstration through EMS integration illustrates the applicability of the proposed methodology and the developed tool for actual grid operation and paves the road for integration with EMS systems in control rooms.

  11. Vascular tissue engineering by computer-aided laser micromachining.

    PubMed

    Doraiswamy, Anand; Narayan, Roger J

    2010-04-28

    Many conventional technologies for fabricating tissue engineering scaffolds are not suitable for fabricating scaffolds with patient-specific attributes. For example, many conventional technologies for fabricating tissue engineering scaffolds do not provide control over overall scaffold geometry or over cell position within the scaffold. In this study, the use of computer-aided laser micromachining to create scaffolds for vascular tissue networks was investigated. Computer-aided laser micromachining was used to construct patterned surfaces in agarose or in silicon, which were used for differential adherence and growth of cells into vascular tissue networks. Concentric three-ring structures were fabricated on agarose hydrogel substrates, in which the inner ring contained human aortic endothelial cells, the middle ring contained HA587 human elastin and the outer ring contained human aortic vascular smooth muscle cells. Basement membrane matrix containing vascular endothelial growth factor and heparin was to promote proliferation of human aortic endothelial cells within the vascular tissue networks. Computer-aided laser micromachining provides a unique approach to fabricate small-diameter blood vessels for bypass surgery as well as other artificial tissues with complex geometries.

  12. The Mathematics of Dispatchability, Revisited

    NASA Technical Reports Server (NTRS)

    Morris, Paul

    2016-01-01

    Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently, it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, dispatchability has considerable theoretical as well as practical significance. One thing that hampers further work in this area is the underdeveloped theory. Moreover, the existing foundation is inadequate in certain respects. In this paper, we develop a new mathematical theory of dispatchability and its relationship to execution. We also provide several characterizations of dispatchability, including characterizations in terms of the structural properties of the STN graph. This facilitates the potential application of the theory to other areas.

  13. The Mathematics of Dispatchability Revisited

    NASA Technical Reports Server (NTRS)

    Morris, Paul

    2016-01-01

    Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, the dispatchability property has both theoretical and practical interest. One thing that hampers further work in this area is the underdeveloped theory. The existing definitions are expressed in terms of algorithms, and are less suitable for mathematical proofs. In this paper, we develop a new formal theory of dispatchability in terms of execution sequences. We exploit this to prove a characterization of dispatchability involving the structural properties of the STN graph. This facilitates the potential application of the theory to uncertainty reasoning.

  14. Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

    PubMed

    Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip

    2014-05-01

    Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.

  15. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    PubMed

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  16. Project-Based Teaching-Learning Computer-Aided Engineering Tools

    ERIC Educational Resources Information Center

    Simoes, J. A.; Relvas, C.; Moreira, R.

    2004-01-01

    Computer-aided design, computer-aided manufacturing, computer-aided analysis, reverse engineering and rapid prototyping are tools that play an important key role within product design. These are areas of technical knowledge that must be part of engineering and industrial design courses' curricula. This paper describes our teaching experience of…

  17. Novel method based on DDE technology for computer-aided alignment

    NASA Astrophysics Data System (ADS)

    Huang, Yifan; Li, Lin

    2008-03-01

    A new method based on Dynamic Data Exchange (DDE) technology for computer-aided alignment is put forward in this paper. It is adopted to realize the automatic data transferring between Matlab and Zemax optical software. Based on the analysis of CAA and its procedure, a self-made program is developed to perform all the CAA steps under Matlab environment. Flow process of this program is shown in this paper. A Gregorian system is adopted as an example to verify the feasibility of the program. Comparisons of the image quality between the misaligned system and the post-aligned system are presented. Results show that this program is very effective.

  18. Computer-aided methods for analysis and synthesis of supersonic cruise aircraft structures

    NASA Technical Reports Server (NTRS)

    Giles, G. L.

    1976-01-01

    Computer-aided methods are reviewed which are being developed by Langley Research Center in-house work and by related grants and contracts. Synthesis methods to size structural members to meet strength and stiffness (flutter) requirements are emphasized and described. Because of the strong interaction among the aerodynamic loads, structural stiffness, and member sizes of supersonic cruise aircraft structures, these methods are combined into systems of computer programs to perform design studies. The approaches used in organizing these systems to provide efficiency, flexibility of use in an iterative process, and ease of system modification are discussed.

  19. Computer-Aided Detection and diagnosis for prostate cancer based on mono and multi-parametric MRI: a review.

    PubMed

    Lemaître, Guillaume; Martí, Robert; Freixenet, Jordi; Vilanova, Joan C; Walker, Paul M; Meriaudeau, Fabrice

    2015-05-01

    Prostate cancer is the second most diagnosed cancer of men all over the world. In the last few decades, new imaging techniques based on Magnetic Resonance Imaging (MRI) have been developed to improve diagnosis. In practise, diagnosis can be affected by multiple factors such as observer variability and visibility and complexity of the lesions. In this regard, computer-aided detection and computer-aided diagnosis systems have been designed to help radiologists in their clinical practice. Research on computer-aided systems specifically focused for prostate cancer is a young technology and has been part of a dynamic field of research for the last 10 years. This survey aims to provide a comprehensive review of the state-of-the-art in this lapse of time, focusing on the different stages composing the work-flow of a computer-aided system. We also provide a comparison between studies and a discussion about the potential avenues for future research. In addition, this paper presents a new public online dataset which is made available to the research community with the aim of providing a common evaluation framework to overcome some of the current limitations identified in this survey.

  20. Physician staffed helicopter emergency medical service dispatch via centralised control or directly by crew – case identification rates and effect on the Sydney paediatric trauma system

    PubMed Central

    2012-01-01

    Background Severe paediatric trauma patients benefit from direct transport to dedicated Paediatric Trauma Centres (PTC). Parallel case identification systems utilising paramedics from a centralised dispatch centre versus the crew of a physician staffed Helicopter Emergency Medical Service (HEMS) allowed comparison of the two systems for case identification rates and subsequent timeliness of direct transfer to a PTC. Methods Paediatric trauma patients over a two year period from the Sydney region with an Injury Severity Score (ISS) > 15 were retrospectively identified from a state wide trauma registry. Overall paediatric trauma system performance was assessed by comparisons of the availability of the physician staffed HEMS for patient characteristics, transport mode (direct versus indirect) and the times required for the patient to arrive at the paediatric trauma centre. The proportion of patients transported directly to a PTC was compared between the times that the HEMS service was available versus the time that it was unavailable to determine if the HEMS system altered the rate of direct transport to a PTC. Analysis of variance was used to compare the identifying systems for various patient characteristics when the HEMS was available. Results Ninety nine cases met the inclusion criteria, 44 when the HEMS system was operational. Patients identified for physician response by the HEMS system were significantly different to those that were not identified with higher median ISS (25 vs 18, p = 0.011), and shorter times to PTC (67 vs 261mins, p = 0.015) and length of intensive care unit stays (2 vs 0 days, p = 0.045). Of the 44 cases, 21 were not identified, 3 were identified by the paramedic system and 20 were identified by the HEMS system, (P < 0.001). Direct transport to a PTC was more likely to occur when the HEMS dispatch system was available (RR 1.81, 95% CI 1.20-2.73). The median time (minutes) to arrival at the PTC was shorter when HEMS

  1. Computer aided detection of surgical retained foreign object for prevention

    SciTech Connect

    Hadjiiski, Lubomir Marentis, Theodore C.; Rondon, Lucas; Chan, Heang-Ping; Chaudhury, Amrita R.; Chronis, Nikolaos

    2015-03-15

    Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10{sup 9} annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96

  2. Computer-aided structural design of a lunar radio telescope

    NASA Technical Reports Server (NTRS)

    Akgul, Ferhat; Gerstle, Walter H.; Johnson, Stewart W.

    1990-01-01

    This paper describes a computer-aided structural design of the main reflector of a fully steerable radio telescope to be located (in the 21st century) on the moon, and presents the results of the structural analysis of the reflector. The reflector is a paraboloid with a surface area of 12,660 sq m and a focal ratio of 0.42. The reflector's surface will be covered by a 5.08 cm-thick sandwich panel made of thin-walled aluminum cells filled with low-density foam. The low weight of the design will be achieved by using graphite-epoxy as the structural material.

  3. Computer Aided Antenna Design and Frequency Selection for HF Communications.

    DTIC Science & Technology

    1984-06-01

    EESIGN ON THE ADPE-.- NIF (GREEN MACHINE) ... .... . . . . . . . 57 E. COMPUTER AIDED DESIGN USING ECAC1S ACCESSIBIE ANTENNA PACKAGE . . . . . . .. 57 F...8217 C8 L4 E-4 W 3a ’H 1 H -g I) - 4 ’ 0-4 =2 E-4 V. E-4 b. m 0 m 4 =- v- -4 3 4 E’- 4 = P4 H - ofC. I- 1 4 = W P4 w 4 I = N = V rq I 0-4 ~ to H W4

  4. Three-Dimensional Computer Aided Design of a Vertical Winnower

    NASA Astrophysics Data System (ADS)

    Bao, Yumei; Lin, Saijia; Weng, Lijie

    The research states home and abroad of the winnowing technology and winnowers are reviewed in brief. For the air duct, the core component of the winnower, the relevant technical parameters in the winnowing process are calculated based on the winnowing principle. The three-dimensional computer aided design (3D-CAD) software Solidworks is applied. The designed vertical winnower is able to separate different raw materials by adjusting the air speed and has been put into practical production to separate the Chinese traditional medicine with high separating effect.

  5. Computer aided design and analysis of gear tooth geometry

    NASA Technical Reports Server (NTRS)

    Chang, S. H.; Huston, R. L.

    1987-01-01

    A simulation method for gear hobbing and shaping of straight and spiral bevel gears is presented. The method is based upon an enveloping theory for gear tooth profile generation. The procedure is applicable in the computer aided design of standard and nonstandard tooth forms. An inverse procedure for finding a conjugate gear tooth profile is presented for arbitrary cutter geometry. The kinematic relations for the tooth surfaces of straight and spiral bevel gears are proposed. The tooth surface equations for these gears are formulated in a manner suitable for their automated numerical development and solution.

  6. Computer-aided design of bevel gear tooth surfaces

    NASA Technical Reports Server (NTRS)

    Shuo, Hung Chang; Huston, Ronald L.; Coy, John J.

    1989-01-01

    This paper presents a computer-aided design procedure for generating bevel gears. The development is based on examining a perfectly plastic, cone-shaped gear blank rolling over a cutting tooth on a plane crown rack. The resulting impression on the plastic gear blank is the envelope of the cutting tooth. This impression and envelope thus form a conjugate tooth surface. Equations are presented for the locus of points on the tooth surface. The same procedures are then extended to simulate the generation of a spiral bevel gear. The corresponding governing equations are presented.

  7. Computer aided design of bevel gear tooth surfaces

    NASA Technical Reports Server (NTRS)

    Chang, S. H.; Huston, R. L.; Coy, J. J.

    1989-01-01

    This paper presents a computer-aided design procedure for generating bevel gears. The development is based on examining a perfectly plastic, cone-shaped gear blank rolling over a cutting tooth on a plane crown rack. The resulting impression on the plastic gear blank is the envelope of the cutting tooth. This impression and envelope thus form a conjugate tooth surface. Equations are presented for the locus of points on the tooth surface. The same procedures are then extended to simulate the generation of a spiral bevel gear. The corresponding governing equations are presented.

  8. SNL Mechanical Computer Aided Design (MCAD) guide 2007.

    SciTech Connect

    Moore, Brandon; Pollice, Stephanie L.; Martinez, Jack R.

    2007-12-01

    This document is considered a mechanical design best-practice guide to new and experienced designers alike. The contents consist of topics related to using Computer Aided Design (CAD) software, performing basic analyses, and using configuration management. The details specific to a particular topic have been leveraged against existing Product Realization Standard (PRS) and Technical Business Practice (TBP) requirements while maintaining alignment with sound engineering and design practices. This document is to be considered dynamic in that subsequent updates will be reflected in the main title, and each update will be published on an annual basis.

  9. Central Police Dispatch: An Exemplary Project.

    ERIC Educational Resources Information Center

    McDonnell, John J.

    The document presents a description of the Central Police Dispatch (PCD) system of Muskegon County, Michigan. The CPD, a civilian-staffed organization, is concerned with the regionalization of police services and improved police communications. The development of the CPD is traced from the Muskegon Interlocal Public Agency (1969-72) to the present…

  10. Research on Computer Aided Innovation Model of Weapon Equipment Requirement Demonstration

    NASA Astrophysics Data System (ADS)

    Li, Yong; Guo, Qisheng; Wang, Rui; Li, Liang

    Firstly, in order to overcome the shortcoming of using only AD or TRIZ solely, and solve the problems currently existed in weapon equipment requirement demonstration, the paper construct the method system of weapon equipment requirement demonstration combining QFD, AD, TRIZ, FA. Then, we construct a CAI model frame of weapon equipment requirement demonstration, which include requirement decomposed model, requirement mapping model and requirement plan optimization model. Finally, we construct the computer aided innovation model of weapon equipment requirement demonstration, and developed CAI software of equipment requirement demonstration.

  11. Computer Aided Design of Computer Generated Holograms for electron beam fabrication

    NASA Technical Reports Server (NTRS)

    Urquhart, Kristopher S.; Lee, Sing H.; Guest, Clark C.; Feldman, Michael R.; Farhoosh, Hamid

    1989-01-01

    Computer Aided Design (CAD) systems that have been developed for electrical and mechanical design tasks are also effective tools for the process of designing Computer Generated Holograms (CGHs), particularly when these holograms are to be fabricated using electron beam lithography. CAD workstations provide efficient and convenient means of computing, storing, displaying, and preparing for fabrication many of the features that are common to CGH designs. Experience gained in the process of designing CGHs with various types of encoding methods is presented. Suggestions are made so that future workstations may further accommodate the CGH design process.

  12. Computer-aided testing of pilot response to critical in-flight events

    NASA Technical Reports Server (NTRS)

    Giffin, W. C.; Rockwell, T. H.

    1984-01-01

    This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.

  13. Flexible structure control experiments using a real-time workstation for computer-aided control engineering

    NASA Technical Reports Server (NTRS)

    Stieber, Michael E.

    1989-01-01

    A Real-Time Workstation for Computer-Aided Control Engineering has been developed jointly by the Communications Research Centre (CRC) and Ruhr-Universitaet Bochum (RUB), West Germany. The system is presently used for the development and experimental verification of control techniques for large space systems with significant structural flexibility. The Real-Time Workstation essentially is an implementation of RUB's extensive Computer-Aided Control Engineering package KEDDC on an INTEL micro-computer running under the RMS real-time operating system. The portable system supports system identification, analysis, control design and simulation, as well as the immediate implementation and test of control systems. The Real-Time Workstation is currently being used by CRC to study control/structure interaction on a ground-based structure called DAISY, whose design was inspired by a reflector antenna. DAISY emulates the dynamics of a large flexible spacecraft with the following characteristics: rigid body modes, many clustered vibration modes with low frequencies and extremely low damping. The Real-Time Workstation was found to be a very powerful tool for experimental studies, supporting control design and simulation, and conducting and evaluating tests withn one integrated environment.

  14. Computer-aided subsite mapping of α-amylases.

    PubMed

    Mótyán, János A; Gyémánt, Gyöngyi; Harangi, János; Bagossi, Péter

    2011-02-15

    Subsite mapping is a crucial procedure in the characterization of α-amylases (EC 3.2.1.1), which are extensively used in starch-based industries and in diagnosis of pancreatic and salivary glands disorders. A computer-aided method has been developed for subsite mapping of α-amylases, which substitutes the difficult, expensive, and time-consuming experimental determination of action patterns to crystal structures based energy calculations. Interaction energies between enzymes and carbohydrate substrates were calculated after short energy minimization by a molecular mechanics program. A training set of wild type and mutant amylases with known experimental action patterns of 13 enzymes of wide range of origin was used to set up the procedure. Calculations for training set resulted in good correlation in case of subsite binding energies (r(2)=0.827-0.929) and bond cleavage frequencies (r(2)=0.727-0.835). A set of eight novel barley amylase 1 mutants was used to test our model. Subsite binding energies were predicted with r(2)=0.502 correlation coefficient, while bond cleavage frequency prediction resulted in r(2)=0.538. Our computer-aided procedure may supplement the experimental subsite mapping methods to predict and understand characteristic features of α-amylases.

  15. Computer-aided tissue engineering of a human vertebral body.

    PubMed

    Wettergreen, M A; Bucklen, B S; Sun, W; Liebschner, M A K

    2005-10-01

    Tissue engineering is developing into a less speculative science involving the careful interplay of numerous design parameters and multidisciplinary professionals. Problem solving abilities and state of the art research tools are required to develop solutions for a wide variety of clinical issues. One area of particular interest is orthopedic biomechanics, a field that is responsible for the treatment of over 700,000 vertebral fractures in the United States alone last year. Engineers are currently lacking the technology and knowledge required to govern the subsistence of cells in vivo, let alone the knowledge to create a functional tissue replacement for a whole organ. Despite this, advances in computer-aided tissue engineering are continually growing. Using a combinatory approach to scaffold design, patient-specific implants may be constructed. Computer-aided design, optimization of geometry using voxel finite element models or other optimization routines, creation of a library of architectures with specific material properties, rapid prototyping, and determination of a defect site using imaging modalities highlight the current availability of design resources. This study proposes a novel methodology from start to finish which could, in the future, be used to design a tissue-engineered construct for the replacement of an entire vertebral body.

  16. Methodology for Benefit Analysis of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) in USN Shipyards.

    DTIC Science & Technology

    1984-03-01

    D-Ri38 398 METHODOLOGY FOR BENEFIT ANALYSIS OF CAD/CAM / (COMPUTER-HIDED DESIGN/COMPUTER-AIDED MANUFACTURING) IN USN SHIPYARDS(U) NAVAL POSTGRADUATE...Monterey, California DT I ~" t • EB3 1984 THESIS METHODOLOGY FOR BENEFIT ANALYSIS OF CAD/CAM IN USN SHIPYARDS by Richard B. Grahlman March 1984 Thesis...REPORT & PERIOD COVERED Methodology for Benefit Analysis of CAD/CAM Mastrch 1984 i in UM Sipyads. PERFORMIANG ORG. REPORT NUM8ER 7- AUHOW11111 4

  17. Multi-Fluid Geo-Energy Systems for Bulk and Thermal Energy Storage and Dispatchable Renewable and Low-Carbon Electricity

    NASA Astrophysics Data System (ADS)

    Buscheck, T. A.; Randolph, J.; Saar, M. O.; Hao, Y.; Sun, Y.; Bielicki, J. M.

    2014-12-01

    Integrating renewable energy sources into electricity grids requires advances in bulk and thermal energy storage technologies, which are currently expensive and have limited capacity. We present an approach that uses the huge fluid and thermal storage capacity of the subsurface to harvest, store, and dispatch energy from subsurface (geothermal) and surface (solar, nuclear, fossil) thermal resources. CO2 captured from fossil-energy systems and N2 separated from air are injected into permeable formations to store pressure, generate artesian flow of brine, and provide additional working fluids. These enable efficient fluid recirculation, heat extraction, and power conversion, while adding operational flexibility. Our approach can also store and dispatch thermal energy, which can be used to levelize concentrating solar power and mitigate variability of wind and solar power. This may allow low-carbon, base-load power to operate at full capacity, with the stored excess energy being available to addresss diurnal and seasonal mismatches between supply and demand. Concentric rings of horizontal injection and production wells are used to create a hydraulic divide to store pressure, CO2, N2, and thermal energy. Such storage can take excess power from the grid and excess thermal energy, and dispatch that energy when it is demanded. The system is pressurized and/or heated when power supply exceeds demand and depressurized when demand exceeds supply. Supercritical CO2 and N2 function as cushion gases to provide enormous pressure-storage capacity. Injecting CO2 and N2 displaces large quantities of brine, reducing the use of fresh water. Geologic CO2 storage is a crucial option for reducing CO2 emissions, but valuable uses for CO2 are needed to justify capture costs. The initial "charging" of our system requires permanently isolating large volumes of CO2 from the atmosphere and thus creates a market for its disposal. Our approach is designed for locations where a permeable

  18. Improved Foundry Castings Utilizing CAD/CAM (Computer Aided Design/ Computer Aided Manufacture). Volume 1. Overview

    DTIC Science & Technology

    1988-06-30

    several organizations. Members of the project staffs at the University of Pittsburgh, Battelle Columbus Laboratories, Blaw - Knox Foundry and Mill...with the University of Pittsburgh, James Echlin, Blaw - Knox , and A. Roulet, General Dynamics. Computing facilities on the DEC 10 system were made...Akgerman, A. Badawy, C. Wilson, and T. Altan. The project staff at Blaw - Knox included Mssrs. R. Nariman, KI Fahey, and S. Miller. Mr. W. Northey

  19. Using old technology to implement modern computer-aided decision support for primary diabetes care.

    PubMed Central

    Hunt, D. L.; Haynes, R. B.; Morgan, D.

    2001-01-01

    BACKGROUND: Implementation rates of interventions known to be beneficial for people with diabetes mellitus are often suboptimal. Computer-aided decision support systems (CDSSs) can improve these rates. The complexity of establishing a fully integrated electronic medical record that provides decision support, however, often prevents their use. OBJECTIVE: To develop a CDSS for diabetes care that can be easily introduced into primary care settings and diabetes clinics. THE SYSTEM: The CDSS uses fax-machine-based optical character recognition software for acquiring patient information. Simple, 1-page paper forms, completed by patients or health practitioners, are faxed to a central location. The information is interpreted and recorded in a database. This initiates a routine that matches the information against a knowledge base so that patient-specific recommendations can be generated. These are formatted and faxed back within 4-5 minutes. IMPLEMENTATION: The system is being introduced into 2 diabetes clinics. We are collecting information on frequency of use of the system, as well as satisfaction with the information provided. CONCLUSION: Computer-aided decision support can be provided in any setting with a fax machine, without the need for integrated electronic medical records or computerized data-collection devices. PMID:11825194

  20. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    PubMed

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p < 0.001). Significant differences in mean costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p < 0.001). Significant differences were also obtained between the costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit.

  1. Computer-aided analysis and design of the shape rolling process for producing turbine engine airfoils

    NASA Technical Reports Server (NTRS)

    Lahoti, G. D.; Akgerman, N.; Altan, T.

    1978-01-01

    Mild steel (AISI 1018) was selected as model cold-rolling material and Ti-6Al-4V and INCONEL 718 were selected as typical hot-rolling and cold-rolling alloys, respectively. The flow stress and workability of these alloys were characterized and friction factor at the roll/workpiece interface was determined at their respective working conditions by conducting ring tests. Computer-aided mathematical models for predicting metal flow and stresses, and for simulating the shape-rolling process were developed. These models utilize the upper-bound and the slab methods of analysis, and are capable of predicting the lateral spread, roll-separating force, roll torque and local stresses, strains and strain rates. This computer-aided design (CAD) system is also capable of simulating the actual rolling process and thereby designing roll-pass schedule in rolling of an airfoil or similar shape. The predictions from the CAD system were verified with respect to cold rolling of mild steel plates. The system is being applied to cold and hot isothermal rolling of an airfoil shape, and will be verified with respect to laboratory experiments under controlled conditions.

  2. Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations

    PubMed Central

    Lee, Ki-Hong; Yeo, In-Sung; Wu, Benjamin M.; Yang, Jae-Ho; Han, Jung-Suk; Kim, Sung-Hun; Yi, Yang-Jin; Kwon, Taek-Ka

    2015-01-01

    Purpose. The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. Materials and Methods. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan's post hoc test were used for data analysis at the significance level of 0.05. Results. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P < 0.001).  Conclusions. Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy. PMID:26557681

  3. Cancellations of (helicopter-transported) mobile medical team dispatches in the Netherlands

    PubMed Central

    Lubbers, Wouter D.; Christiaans, Herman M. T.; van Exter, Pieternel; Bet, Piet; Hugen, Paul J. C.; Innemee, Gerard; Schubert, Edo; de Lange-Klerk, Elly S. M.; Goslings, J. Carel; Jukema, Gerrolt N.

    2010-01-01

    Background The trauma centre of the Trauma Center Region North-West Netherlands (TRNWN) has consensus criteria for Mobile Medical Team (MMT) scene dispatch. The MMT can be dispatched by the EMS-dispatch centre or by the on-scene ambulance crew and is transported by helicopter or ground transport. Although much attention has been paid to improve the dispatch criteria, the MMT is often cancelled after being dispatched. The aim of this study was to assess the cancellation rate and the noncompliant dispatches of our MMT and to identify factors associated with this form of primary overtriage. Methods By retrospective analysis of all MMT dispatches in the period from 1 July 2006 till 31 December 2006 using chart review, we conducted a consecutive case review of 605 dispatches. Four hundred and sixty seven of these were included for our study, collecting data related to prehospital triage, patient’s condition on-scene and hospital course. Results Average age was 35.9 years; the majority of the patients were male (65.3%). Four hundred and thirty patients were victims of trauma, sustaining injuries in most cases from blunt trauma (89.3%). After being dispatched, the MMT was cancelled 203 times (43.5%). Statistically significant differences between assists and cancellations were found for overall mortality, mean RTS, GCS and ISS, mean hospitalization, length and amount of ICU admissions (p < 0.001). All dispatches were evaluated by using the MMT-dispatch criteria and mission appropriateness criteria. Almost 26% of all dispatches were neither appropriate, nor met the dispatch criteria. Fourteen missions were appropriate, but did not meet the dispatch criteria. The remaining 318 dispatches had met the dispatch criteria, of which 135 (30.3%) were also appropriate. The calculated additional costs of the cancelled dispatches summed up to a total of € 34,448, amounting to 2.2% of the total MMT costs during the study period. Conclusion In our trauma system, the MMT

  4. Comparative study viruses with computer-aided phase microscope AIRYSCAN

    NASA Astrophysics Data System (ADS)

    Tychinsky, Vladimir P.; Koufal, Georgy E.; Perevedentseva, Elena V.; Vyshenskaia, Tatiana V.

    1996-12-01

    Traditionally viruses are studied with scanning electron microscopy (SEM) after complicated procedure of sample preparation without the possibility to study it under natural conditions. We obtained images of viruses (Vaccinia virus, Rotavirus) and rickettsias (Rickettsia provazekii, Coxiella burnetti) in native state with computer-aided phase microscope airyscan -- the interference microscope of Linnik layout with phase modulation of the reference wave with dissector image tube as coordinate-sensitive photodetector and computer processing of phase image. A light source was the He-Ne laser. The main result is coincidence of dimensions and shape of phase images with available information concerning their morphology obtained with SEM and other methods. The fine structure of surface and nuclei is observed. This method may be applied for virus recognition and express identification, investigation of virus structure and the analysis of cell-virus interaction.

  5. Shape Signatures: speeding up computer aided drug discovery.

    PubMed

    Meek, Peter J; Liu, ZhiWei; Tian, LiFeng; Wang, Ching Y; Welsh, William J; Zauhar, Randy J

    2006-10-01

    Identifying potential lead molecules is becoming a more automated process. We review Shape Signatures, a tool that is effective and easy to use compared with most computer aided drug design techniques. Laboratory researchers can apply this in silico technique cost-effectively without the need for specialized computer backgrounds. Identifying a potential lead molecule requires database screening, and this becomes rate-limiting once the database becomes too large. The use of Shape Signatures eliminates this concern and offers molecule screening rates that are in advance of any currently available method. Shape Signatures provides a conduit for researchers to conduct rapid identification of potential active molecules, and studies with this tool can be initiated with only one bioactive lead or receptor site.

  6. Application of artificial neural networks in computer-aided diagnosis.

    PubMed

    Liu, Bei

    2015-01-01

    Computer-aided diagnosis is a diagnostic procedure in which a radiologist uses the outputs of computer analysis of medical images as a second opinion in the interpretation of medical images, either to help with lesion detection or to help determine if the lesion is benign or malignant. Artificial neural networks (ANNs) are usually employed to formulate the statistical models for computer analysis. Receiver operating characteristic curves are used to evaluate the performance of the ANN alone, as well as the diagnostic performance of radiologists who take into account the ANN output as a second opinion. In this chapter, we use mammograms to illustrate how an ANN model is trained, tested, and evaluated, and how a radiologist should use the ANN output as a second opinion in CAD.

  7. Computer-aided optimization of phosphinic inhibitors of bacterial ureases.

    PubMed

    Vassiliou, Stamatia; Kosikowska, Paulina; Grabowiecka, Agnieszka; Yiotakis, Athanasios; Kafarski, Paweł; Berlicki, Lukasz

    2010-08-12

    Urease inhibitors can be considered as a tool to control the damaging effect of ureolytic bacteria infections in humans which occur commonly in the developed countries. Computer-aided optimization of the aminomethylphosphinate structures by modifying both their N- and P-termini led to the invention of a novel group of inhibitors of bacterial ureases. Introduction of P-hydroxymethyl group into the molecule resulted in considerable increase of the inhibitory activity against enzymes purified from Bacillus pasteurii and Proteus vulgaris as compared with their P-methyl counterparts described previously. The designed compounds represent a competitive reversible class of urease inhibitors. The most potent, N-methyl-aminomethyl-P-hydroxymethylphosphinic acid, displayed K(i) = 360 nM against P. vulgaris enzyme.

  8. Does computer-aided formative assessment improve learning outcomes?

    NASA Astrophysics Data System (ADS)

    Hannah, John; James, Alex; Williams, Phillipa

    2014-02-01

    Two first-year engineering mathematics courses used computer-aided assessment (CAA) to provide students with opportunities for formative assessment via a series of weekly quizzes. Most students used the assessment until they achieved very high (>90%) quiz scores. Although there is a positive correlation between these quiz marks and the final exam marks, spending time on the CAA component of the course was negatively correlated with final exam performance. Students across the ability spectrum reduced their time commitment to CAA in their second semester, with weaker students achieving lower quiz totals, but with more able students' quiz marks hardly affected. Despite this lower quiz performance, the weaker students still improved their final exam marks in the second semester.

  9. Computer-aided detection of polyps in optical colonoscopy images

    NASA Astrophysics Data System (ADS)

    Nadeem, Saad; Kaufman, Arie

    2016-03-01

    We present a computer-aided detection algorithm for polyps in optical colonoscopy images. Polyps are the precursors to colon cancer. In the US alone, 14 million optical colonoscopies are performed every year, mostly to screen for polyps. Optical colonoscopy has been shown to have an approximately 25% polyp miss rate due to the convoluted folds and bends present in the colon. In this work, we present an automatic detection algorithm to detect these polyps in the optical colonoscopy images. We use a machine learning algorithm to infer a depth map for a given optical colonoscopy image and then use a detailed pre-built polyp profile to detect and delineate the boundaries of polyps in this given image. We have achieved the best recall of 84.0% and the best specificity value of 83.4%.

  10. Virus structure using the computer-aided phase microscope Airyscan

    NASA Astrophysics Data System (ADS)

    Tychinsky, Vladimir P.; Kaverin, Nikolai V.; Perevedentseva, Elena V.; Vyshenskaia, Tatiana V.; Kufal, Georgy E.

    1997-04-01

    Investigation of features and functions of some small biological objects (smaller than 500 nm), in particular, viruses, with conventional optical microscopy is practically impossible. Usually their images are obtained with methods of scanning electron microscopy (SEM), which precludes work with samples in a native state. We obtained images of different viruses including influenza A virus in native state with computer-aided phase microscope (CPM) Airyscan, in which an He-Ne laser is used as a light source. The main purpose of this work was to show the possibility to obtain adequate structure images of influenza viruses with diameter about 100 nm in conditions quite close to native and to investigate different stages of influenza virus budding. We suppose that these results may be considered as a basis for further studies of cell-virus interaction.

  11. Computer-aided conceptual design of Air Cushion Vehicles

    NASA Astrophysics Data System (ADS)

    Band, E. G. U.; Lavis, D. R.

    This paper describes the development and use of a computer-aided design tool which has been used to explore preferred options for amphibious Air-Cushion Vehicle (ACV) and Surface-Effect Ship (SES) designs in support of U.S. Navy and U.S. Army programs. The tool, referred to as the ACV Design Synthesis Model (ADSM), is an interactive computer program which provides a description of feasible ACV or SES concepts that could be developed, by a competent design team, to perform the mission described by the input parameters. The paper discusses how the program was used to explore parametrically the design of a range of self-propelled hoverbarges to meet requirements of the U.S. Army Logistics Over the Shore (LOTS) phases of an amphibious landing. Examples of results are presented to illustrate the method used in determining design and performance trade-offs.

  12. Computer-aided dosage in oral anticoagulation therapy using phenprocoumon. Problems and approaches.

    PubMed

    Cromme, L; Völler, H; Gäbler, F; Salzwedel, A; Taborski, U

    2010-11-01

    Oral anticoagulation using vitamin K antagonists has been established for over 50 years. Although it is highly effective in preventing thromboembolic incidents, its therapeutic control still remains problematic. Therefore, a computer-aided approach is recommended for deriving dosages. Up to now, the dosage is often based on the visual inspection of previous INR measurements, average weekly doses, and the INR target range. Statistical variations of measurement results and time-delayed effects of dosages, however, frequently result in the misinterpretation of data and suggest pseudo-trends. Treating physicians are not only responsible for determining the patient-specific maintenance dose, but must also respond to deviating INR values, overdosage or underdosage, initiate the oral anticoagulation therapy, and control the INR level in case of a new target range (bridging). Instructive examples are provided to illustrate the described difficulties. A computer-aided expert system is currently developed to ensure the therapeutic safety under the specified conditions. We present preliminary results from a study designed to validate mathematical models underlying such expert systems.

  13. Fatigue analysis of computer-aided design/computer-aided manufacturing resin-based composite vs. lithium disilicate glass-ceramic.

    PubMed

    Ankyu, Shuhei; Nakamura, Keisuke; Harada, Akio; Hong, Guang; Kanno, Taro; Niwano, Yoshimi; Örtengren, Ulf; Egusa, Hiroshi

    2016-08-01

    Resin-based composite molar crowns made by computer-aided design/computer-aided manufacturing (CAD/CAM) systems have been proposed as an inexpensive alternative to metal-ceramic or all-ceramic crowns. However, there is a lack of scientific information regarding fatigue resistance. This study aimed to analyze the fatigue behavior of CAD/CAM resin-based composite compared with lithium disilicate glass-ceramic. One-hundred and sixty bar-shaped specimens were fabricated using resin-based composite blocks [Lava Ultimate (LU); 3M/ESPE] and lithium disilicate glass-ceramic [IPS e.max press (EMP); Ivoclar/Vivadent]. The specimens were divided into four groups: no treatment (NT); thermal cycling (TC); mechanical cycling (MC); and thermal cycling followed by mechanical cycling (TCMC). Thermal cycling was performed by alternate immersion in water baths of 5°C and 55°C for 5 × 10(4) cycles. Mechanical cycling was performed in a three-point bending test, with a maximum load of 40 N, for 1.2 × 10(6) cycles. In addition, LU and EMP molar crowns were fabricated and subjected to fatigue treatments followed by load-to-failure testing. The flexural strength of LU was not severely reduced by the fatigue treatments. The fatigue treatments did not significantly affect the fracture resistance of LU molar crowns. The results demonstrate the potential of clinical application of CAD/CAM-generated resin-based composite molar crowns in terms of fatigue resistance.

  14. The application of computer-aided technologies in automotive styling design

    NASA Astrophysics Data System (ADS)

    Zheng, Ze-feng; Zhang, Ji; Zheng, Ying

    2012-04-01

    In automotive industry, outline design is its life and creative design is its soul indeed. Computer-aided technology has been widely used in the automotive industry and more and more attention has been paid. This paper chiefly introduce the application of computer-aided technologies including CAD, CAM and CAE, analyses the process of automotive structural design and describe the development tendency of computer-aided design.

  15. Converting Between PLY and Ballistic Research Laboratory-Computer-Aided Design (BRL-CAD) File Formats

    DTIC Science & Technology

    2015-02-01

    Converting Between PLY and Ballistic Research Laboratory–Computer-Aided Design (BRL-CAD) File Formats by Rishub Jain ARL-CR-0760...0760 February 2015 Converting Between PLY and Ballistic Research Laboratory–Computer-Aided Design (BRL-CAD) File Formats Rishub Jain US...and Ballistic Research Laboratory–Computer-Aided Design (BRL-CAD) File Formats 5a. CONTRACT NUMBER W911NF-10-2-0076 5b. GRANT NUMBER 5c. PROGRAM

  16. Target Impact Detection Algorithm Using Computer-aided Design (CAD) Model Geometry

    DTIC Science & Technology

    2014-09-01

    UNCLASSIFIED AD-E403 558 Technical Report ARMET-TR-13024 TARGET IMPACT DETECTION ALGORITHM USING COMPUTER-AIDED DESIGN ( CAD ...DETECTION ALGORITHM USING COMPUTER-AIDED DESIGN ( CAD ) MODEL GEOMETRY 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...This report documents a method and algorithm to export geometry from a three-dimensional, computer-aided design ( CAD ) model in a format that can be

  17. Proceedings of the NATO-Advanced Study Institute on Computer Aided Analysis of Rigid and Flexible Mechanical Systems Held in Troia, Portugal on 27 Jun-9 Jul, 1993. Volume 2. Contributed Papers

    DTIC Science & Technology

    1993-07-09

    possibility and several alternatives have been proposed iS The relative linear velocity measured at the points Q, and Q. can be defined by’ =ui+ 4e +o = o’ (2...jointsis taken into account In the formulation by Introducing the explicit constraint equations an open-loop system subject to the constraint equations of... account several efficiency issues. The algontm is as follows. I2 L__.. . 1. Define the topology of the mulubody system and label all the bodies. joints

  18. CAMEO-Valdez: A user's perspective. [Computer-Aided Management of Emergency Operations

    SciTech Connect

    Haas, T.J.

    1990-01-11

    On the morning of March 24, 1989, the tanker EXXON VALDEZ ran aground on Bligh Reef in Alaska's Prince William Sound. The vessel was carrying over 53 million gallons of North Slope crude oil of which almost 11 million gallons were spilled in the water. The immediately impacted area included most of the western part of the Sound, but eventually, the area expanded to include parts of Seward, Homer, and Kodiak. This event constituted the worst oil spill in the history of this country, and was identified as a 'spill of national significance.' A major response to clean up the oil by EXXON, which was closely monitored by Federal and State agencies and various interest groups, was necessary. Early in the response it was obvious to the Federal On-Scene Coordinator (FOSC) that a computer-aided management system was necessary to monitor the progress of the spill clean-up operations. This paper will describe CAMEO (Computer-Aided Management of Emergency Operations) - Valdez, developed for the FOSC by the National Oceanographic and Atmospheric Administration acting in its role as the Scientific Support Coordinator (SSC). A discussion of how CAMEO was used and an evaluation of its effectiveness will also be presented.

  19. Computer-aided Detection of Prostate Cancer with MRI: Technology and Applications.

    PubMed

    Liu, Lizhi; Tian, Zhiqiang; Zhang, Zhenfeng; Fei, Baowei

    2016-08-01

    One in six men will develop prostate cancer in his lifetime. Early detection and accurate diagnosis of the disease can improve cancer survival and reduce treatment costs. Recently, imaging of prostate cancer has greatly advanced since the introduction of multiparametric magnetic resonance imaging (mp-MRI). Mp-MRI consists of T2-weighted sequences combined with functional sequences including dynamic contrast-enhanced MRI, diffusion-weighted MRI, and magnetic resonance spectroscopy imaging. Because of the big data and variations in imaging sequences, detection can be affected by multiple factors such as observer variability and visibility and complexity of the lesions. To improve quantitative assessment of the disease, various computer-aided detection systems have been designed to help radiologists in their clinical practice. This review paper presents an overview of literatures on computer-aided detection of prostate cancer with mp-MRI, which include the technology and its applications. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application.

  20. Miscellaneous Topics in Computer-Aided Drug Design: Synthetic Accessibility and GPU Computing, and Other Topics

    PubMed Central

    Fukunishi, Yoshifumi; Mashimo, Tadaaki; Misoo, Kiyotaka; Wakabayashi, Yoshinori; Miyaki, Toshiaki; Ohta, Seiji; Nakamura, Mayu; Ikeda, Kazuyoshi

    2016-01-01

    Abstract: Background Computer-aided drug design is still a state-of-the-art process in medicinal chemistry, and the main topics in this field have been extensively studied and well reviewed. These topics include compound databases, ligand-binding pocket prediction, protein-compound docking, virtual screening, target/off-target prediction, physical property prediction, molecular simulation and pharmacokinetics/pharmacodynamics (PK/PD) prediction. Message and Conclusion: However, there are also a number of secondary or miscellaneous topics that have been less well covered. For example, methods for synthesizing and predicting the synthetic accessibility (SA) of designed compounds are important in practical drug development, and hardware/software resources for performing the computations in computer-aided drug design are crucial. Cloud computing and general purpose graphics processing unit (GPGPU) computing have been used in virtual screening and molecular dynamics simulations. Not surprisingly, there is a growing demand for computer systems which combine these resources. In the present review, we summarize and discuss these various topics of drug design. PMID:27075578