Sample records for computer-assisted image analysis

  1. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.

    PubMed

    Handels, H; Ehrhardt, J

    2009-01-01

    Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or operation planning is a complex interdisciplinary process. Image computing methods enable new insights into the patient's image data and have the future potential to improve medical diagnostics and patient treatment.

  2. Computer Assisted Thermography And Its Application In Ovulation Detection

    NASA Astrophysics Data System (ADS)

    Rao, K. H.; Shah, A. V.

    1984-08-01

    Hardware and software of a computer-assisted image analyzing system used for infrared images in medical applications are discussed. The application of computer-assisted thermography (CAT) as a complementary diagnostic tool in centralized diagnostic management is proposed. The authors adopted 'Computer Assisted Thermography' to study physiological changes in the breasts related to the hormones characterizing the menstrual cycle of a woman. Based on clinical experi-ments followed by thermal image analysis, they suggest that 'differential skin temperature (DST)1 be measured to detect the fertility interval in the menstrual cycle of a woman.

  3. Quantitative Enzymatic and Immunologic Histophotometry of Diseased Human Kid-Ney Tissues Using Tv-Camera and Computer Assisted Image Processing Systems.

    NASA Astrophysics Data System (ADS)

    Heinert, G.; Mondorf, W.

    1982-11-01

    High speed image processing was used to analyse morphologic and metabolic characteristics of clinically relevant kidney tissue alterations.Qualitative computer-assisted histophotometry was performed to measure alterations in levels of the enzymes alkaline phosphatase (Ap),alanine aminopeptidase (AAP),g-glutamyltranspepti-dase (GGTP) and A-glucuronidase (B-G1) and AAP and GGTP immunologically determined in prepared renal and cancer tissue sections. A "Mioro-Videomat 2" image analysis system with a "Tessovar" macroscope,a computer-assisted "Axiomat" photomicroscope and an "Interactive Image Analysis System (IBAS)" were employed for analysing changes in enzyme activities determined by changes in absorbance or transmission.Diseased kidney as well as renal neoplastic tissues could be distinguished by significantly (wilcoxon test,p<0,05) decreased enzyme concentrations as compared to those found in normal human kidney tissues.This image analysis techniques might be of potential use in diagnostic and prognostic evaluation of renal cancer and diseased kidney tissues.

  4. Histopathological Image Analysis: A Review

    PubMed Central

    Gurcan, Metin N.; Boucheron, Laura; Can, Ali; Madabhushi, Anant; Rajpoot, Nasir; Yener, Bulent

    2010-01-01

    Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches to radiological data. With the recent advent of whole slide digital scanners, tissue histopathology slides can now be digitized and stored in digital image form. Consequently, digitized tissue histopathology has now become amenable to the application of computerized image analysis and machine learning techniques. Analogous to the role of computer-assisted diagnosis (CAD) algorithms in medical imaging to complement the opinion of a radiologist, CAD algorithms have begun to be developed for disease detection, diagnosis, and prognosis prediction to complement to the opinion of the pathologist. In this paper, we review the recent state of the art CAD technology for digitized histopathology. This paper also briefly describes the development and application of novel image analysis technology for a few specific histopathology related problems being pursued in the United States and Europe. PMID:20671804

  5. Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.

    PubMed

    Kemp, Pavlina S; VanderVeen, Deborah K

    2016-01-01

    The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding the presence of plus disease, an important criterion in deciding the necessity of treatment of vision-threatening retinopathy of prematurity. A review of literature found that several techniques have been published examining the process and role of computer aided analysis of plus disease in retinopathy of prematurity. These techniques use semiautomated image analysis techniques to evaluate retinal vascular dilation and tortuosity, using calculated parameters to evaluate presence or absence of plus disease. These values are then compared with expert consensus. The study concludes that computer-aided image analysis has the potential to use quantitative and objective criteria to act as a supplemental tool in evaluating for plus disease in the setting of retinopathy of prematurity.

  6. Computer-assisted image analysis to quantify daily growth rates of broiler chickens.

    PubMed

    De Wet, L; Vranken, E; Chedad, A; Aerts, J M; Ceunen, J; Berckmans, D

    2003-09-01

    1. The objective was to investigate the possibility of detecting daily body weight changes of broiler chickens with computer-assisted image analysis. 2. The experiment included 50 broiler chickens reared under commercial conditions. Ten out of 50 chickens were randomly selected and video recorded (upper view) 18 times during the 42-d growing period. The number of surface and periphery pixels from the images was used to derive a relationship between body dimension and live weight. 3. The relative error in weight estimation, expressed in terms of the standard deviation of the residuals from image surface data was 10%, while it was found to be 15% for the image periphery data. 4. Image-processing systems could be developed to assist the farmer in making important management and marketing decisions.

  7. Ki-67 reactivity in breast carcinoma analyzed by a computer-assisted image system: preliminary results.

    PubMed Central

    Mir, R.; Johnson, H.; Mathur, R.; Wise, L.; Kahn, L. B.

    1995-01-01

    The proliferative index of 63 breast carcinomas was measured on Ki-67 immunostained frozen tissue sections with a computer-assisted image analysis system. The mean proliferative index in estrogen-positive breast carcinomas was lower than in estrogen-negative carcinomas. An inverse relationship between proliferative index and short-term disease-free survival was noted. Images Figure 1 Figure 2 PMID:7674345

  8. Plasma cell quantification in bone marrow by computer-assisted image analysis.

    PubMed

    Went, P; Mayer, S; Oberholzer, M; Dirnhofer, S

    2006-09-01

    Minor and major criteria for the diagnosis of multiple meloma according to the definition of the WHO classification include different categories of the bone marrow plasma cell count: a shift from the 10-30% group to the > 30% group equals a shift from a minor to a major criterium, while the < 10% group does not contribute to the diagnosis. Plasma cell fraction in the bone marrow is therefore critical for the classification and optimal clinical management of patients with plasma cell dyscrasias. The aim of this study was (i) to establish a digital image analysis system able to quantify bone marrow plasma cells and (ii) to evaluate two quantification techniques in bone marrow trephines i.e. computer-assisted digital image analysis and conventional light-microscopic evaluation. The results were compared regarding inter-observer variation of the obtained results. Eighty-seven patients, 28 with multiple myeloma, 29 with monoclonal gammopathy of undetermined significance, and 30 with reactive plasmocytosis were included in the study. Plasma cells in H&E- and CD138-stained slides were quantified by two investigators using light-microscopic estimation and computer-assisted digital analysis. The sets of results were correlated with rank correlation coefficients. Patients were categorized according to WHO criteria addressing the plasma cell content of the bone marrow (group 1: 0-10%, group 2: 11-30%, group 3: > 30%), and the results compared by kappa statistics. The degree of agreement in CD138-stained slides was higher for results obtained using the computer-assisted image analysis system compared to light microscopic evaluation (corr.coeff. = 0.782), as was seen in the intra- (corr.coeff. = 0.960) and inter-individual results correlations (corr.coeff. = 0.899). Inter-observer agreement for categorized results (SM/PW: kappa 0.833) was in a high range. Computer-assisted image analysis demonstrated a higher reproducibility of bone marrow plasma cell quantification. This might be of critical importance for diagnosis, clinical management and prognostics when plasma cell numbers are low, which makes exact quantifications difficult.

  9. A comparative study between xerographic, computer-assisted overlay generation and animated-superimposition methods in bite mark analyses.

    PubMed

    Tai, Meng Wei; Chong, Zhen Feng; Asif, Muhammad Khan; Rahmat, Rabiah A; Nambiar, Phrabhakaran

    2016-09-01

    This study was to compare the suitability and precision of xerographic and computer-assisted methods for bite mark investigations. Eleven subjects were asked to bite on their forearm and the bite marks were photographically recorded. Alginate impressions of the subjects' dentition were taken and their casts were made using dental stone. The overlays generated by xerographic method were obtained by photocopying the subjects' casts and the incisal edge outlines were then transferred on a transparent sheet. The bite mark images were imported into Adobe Photoshop® software and printed to life-size. The bite mark analyses using xerographically generated overlays were done by comparing an overlay to the corresponding printed bite mark images manually. In computer-assisted method, the subjects' casts were scanned into Adobe Photoshop®. The bite mark analyses using computer-assisted overlay generation were done by matching an overlay and the corresponding bite mark images digitally using Adobe Photoshop®. Another comparison method was superimposing the cast images with corresponding bite mark images employing the Adobe Photoshop® CS6 and GIF-Animator©. A score with a range of 0-3 was given during analysis to each precision-determining criterion and the score was increased with better matching. The Kruskal Wallis H test showed significant difference between the three sets of data (H=18.761, p<0.05). In conclusion, bite mark analysis using the computer-assisted animated-superimposition method was the most accurate, followed by the computer-assisted overlay generation and lastly the xerographic method. The superior precision contributed by digital method is discernible despite the human skin being a poor recording medium of bite marks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Quantitative morphometrical characterization of human pronuclear zygotes.

    PubMed

    Beuchat, A; Thévenaz, P; Unser, M; Ebner, T; Senn, A; Urner, F; Germond, M; Sorzano, C O S

    2008-09-01

    Identification of embryos with high implantation potential remains a challenge in in vitro fertilization (IVF). Subjective pronuclear (PN) zygote scoring systems have been developed for that purpose. The aim of this work was to provide a software tool that enables objective measuring of morphological characteristics of the human PN zygote. A computer program was created to analyse zygote images semi-automatically, providing precise morphological measurements. The accuracy of this approach was first validated by comparing zygotes from two different IVF centres with computer-assisted measurements or subjective scoring. Computer-assisted measurement and subjective scoring were then compared for their ability to classify zygotes with high and low implantation probability by using a linear discriminant analysis. Zygote images coming from the two IVF centres were analysed with the software, resulting in a series of precise measurements of 24 variables. Using subjective scoring, the cytoplasmic halo was the only feature which was significantly different between the two IVF centres. Computer-assisted measurements revealed significant differences between centres in PN centring, PN proximity, cytoplasmic halo and features related to nucleolar precursor bodies distribution. The zygote classification error achieved with the computer-assisted measurements (0.363) was slightly inferior to that of the subjective ones (0.393). A precise and objective characterization of the morphology of human PN zygotes can be achieved by the use of an advanced image analysis tool. This computer-assisted analysis allows for a better morphological characterization of human zygotes and can be used for classification.

  11. Tissue classification for laparoscopic image understanding based on multispectral texture analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Wirkert, Sebastian J.; Iszatt, Justin; Kenngott, Hannes; Wagner, Martin; Mayer, Benjamin; Stock, Christian; Clancy, Neil T.; Elson, Daniel S.; Maier-Hein, Lena

    2016-03-01

    Intra-operative tissue classification is one of the prerequisites for providing context-aware visualization in computer-assisted minimally invasive surgeries. As many anatomical structures are difficult to differentiate in conventional RGB medical images, we propose a classification method based on multispectral image patches. In a comprehensive ex vivo study we show (1) that multispectral imaging data is superior to RGB data for organ tissue classification when used in conjunction with widely applied feature descriptors and (2) that combining the tissue texture with the reflectance spectrum improves the classification performance. Multispectral tissue analysis could thus evolve as a key enabling technique in computer-assisted laparoscopy.

  12. Political leaders and the media. Can we measure political leadership images in newspapers using computer-assisted content analysis?

    PubMed

    Aaldering, Loes; Vliegenthart, Rens

    Despite the large amount of research into both media coverage of politics as well as political leadership, surprisingly little research has been devoted to the ways political leaders are discussed in the media. This paper studies whether computer-aided content analysis can be applied in examining political leadership images in Dutch newspaper articles. It, firstly, provides a conceptualization of political leader character traits that integrates different perspectives in the literature. Moreover, this paper measures twelve political leadership images in media coverage, based on a large-scale computer-assisted content analysis of Dutch media coverage (including almost 150.000 newspaper articles), and systematically tests the quality of the employed measurement instrument by assessing the relationship between the images, the variance in the measurement, the over-time development of images for two party leaders and by comparing the computer results with manual coding. We conclude that the computerized content analysis provides a valid measurement for the leadership images in Dutch newspapers. Moreover, we find that the dimensions political craftsmanship, vigorousness, integrity, communicative performances and consistency are regularly applied in discussing party leaders, but that portrayal of party leaders in terms of responsiveness is almost completely absent in Dutch newspapers.

  13. Retinal imaging analysis based on vessel detection.

    PubMed

    Jamal, Arshad; Hazim Alkawaz, Mohammed; Rehman, Amjad; Saba, Tanzila

    2017-07-01

    With an increase in the advancement of digital imaging and computing power, computationally intelligent technologies are in high demand to be used in ophthalmology cure and treatment. In current research, Retina Image Analysis (RIA) is developed for optometrist at Eye Care Center in Management and Science University. This research aims to analyze the retina through vessel detection. The RIA assists in the analysis of the retinal images and specialists are served with various options like saving, processing and analyzing retinal images through its advanced interface layout. Additionally, RIA assists in the selection process of vessel segment; processing these vessels by calculating its diameter, standard deviation, length, and displaying detected vessel on the retina. The Agile Unified Process is adopted as the methodology in developing this research. To conclude, Retina Image Analysis might help the optometrist to get better understanding in analyzing the patient's retina. Finally, the Retina Image Analysis procedure is developed using MATLAB (R2011b). Promising results are attained that are comparable in the state of art. © 2017 Wiley Periodicals, Inc.

  14. Computer-Assisted Microscopy in Science Teaching and Research.

    ERIC Educational Resources Information Center

    Radice, Gary P.

    1997-01-01

    Describes a technological approach to teaching the relationships between biological form and function. Computer-assisted image analysis was integrated into a microanatomy course. Students spend less time memorizing and more time observing, measuring, and interpreting, building technical and analytical skills. Appendices list hardware and software…

  15. Computer-assisted adjuncts for aneurysmal morphologic assessment: toward more precise and accurate approaches

    NASA Astrophysics Data System (ADS)

    Rajabzadeh-Oghaz, Hamidreza; Varble, Nicole; Davies, Jason M.; Mowla, Ashkan; Shakir, Hakeem J.; Sonig, Ashish; Shallwani, Hussain; Snyder, Kenneth V.; Levy, Elad I.; Siddiqui, Adnan H.; Meng, Hui

    2017-03-01

    Neurosurgeons currently base most of their treatment decisions for intracranial aneurysms (IAs) on morphological measurements made manually from 2D angiographic images. These measurements tend to be inaccurate because 2D measurements cannot capture the complex geometry of IAs and because manual measurements are variable depending on the clinician's experience and opinion. Incorrect morphological measurements may lead to inappropriate treatment strategies. In order to improve the accuracy and consistency of morphological analysis of IAs, we have developed an image-based computational tool, AView. In this study, we quantified the accuracy of computer-assisted adjuncts of AView for aneurysmal morphologic assessment by performing measurement on spheres of known size and anatomical IA models. AView has an average morphological error of 0.56% in size and 2.1% in volume measurement. We also investigate the clinical utility of this tool on a retrospective clinical dataset and compare size and neck diameter measurement between 2D manual and 3D computer-assisted measurement. The average error was 22% and 30% in the manual measurement of size and aneurysm neck diameter, respectively. Inaccuracies due to manual measurements could therefore lead to wrong treatment decisions in 44% and inappropriate treatment strategies in 33% of the IAs. Furthermore, computer-assisted analysis of IAs improves the consistency in measurement among clinicians by 62% in size and 82% in neck diameter measurement. We conclude that AView dramatically improves accuracy for morphological analysis. These results illustrate the necessity of a computer-assisted approach for the morphological analysis of IAs.

  16. Physics and engineering aspects of cell and tissue imaging systems: microscopic devices and computer assisted diagnosis.

    PubMed

    Chen, Xiaodong; Ren, Liqiang; Zheng, Bin; Liu, Hong

    2013-01-01

    The conventional optical microscopes have been used widely in scientific research and in clinical practice. The modern digital microscopic devices combine the power of optical imaging and computerized analysis, archiving and communication techniques. It has a great potential in pathological examinations for improving the efficiency and accuracy of clinical diagnosis. This chapter reviews the basic optical principles of conventional microscopes, fluorescence microscopes and electron microscopes. The recent developments and future clinical applications of advanced digital microscopic imaging methods and computer assisted diagnosis schemes are also discussed.

  17. NiftyNet: a deep-learning platform for medical imaging.

    PubMed

    Gibson, Eli; Li, Wenqi; Sudre, Carole; Fidon, Lucas; Shakir, Dzhoshkun I; Wang, Guotai; Eaton-Rosen, Zach; Gray, Robert; Doel, Tom; Hu, Yipeng; Whyntie, Tom; Nachev, Parashkev; Modat, Marc; Barratt, Dean C; Ourselin, Sébastien; Cardoso, M Jorge; Vercauteren, Tom

    2018-05-01

    Medical image analysis and computer-assisted intervention problems are increasingly being addressed with deep-learning-based solutions. Established deep-learning platforms are flexible but do not provide specific functionality for medical image analysis and adapting them for this domain of application requires substantial implementation effort. Consequently, there has been substantial duplication of effort and incompatible infrastructure developed across many research groups. This work presents the open-source NiftyNet platform for deep learning in medical imaging. The ambition of NiftyNet is to accelerate and simplify the development of these solutions, and to provide a common mechanism for disseminating research outputs for the community to use, adapt and build upon. The NiftyNet infrastructure provides a modular deep-learning pipeline for a range of medical imaging applications including segmentation, regression, image generation and representation learning applications. Components of the NiftyNet pipeline including data loading, data augmentation, network architectures, loss functions and evaluation metrics are tailored to, and take advantage of, the idiosyncracies of medical image analysis and computer-assisted intervention. NiftyNet is built on the TensorFlow framework and supports features such as TensorBoard visualization of 2D and 3D images and computational graphs by default. We present three illustrative medical image analysis applications built using NiftyNet infrastructure: (1) segmentation of multiple abdominal organs from computed tomography; (2) image regression to predict computed tomography attenuation maps from brain magnetic resonance images; and (3) generation of simulated ultrasound images for specified anatomical poses. The NiftyNet infrastructure enables researchers to rapidly develop and distribute deep learning solutions for segmentation, regression, image generation and representation learning applications, or extend the platform to new applications. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Effects of Image Compression on Automatic Count of Immunohistochemically Stained Nuclei in Digital Images

    PubMed Central

    López, Carlos; Lejeune, Marylène; Escrivà, Patricia; Bosch, Ramón; Salvadó, Maria Teresa; Pons, Lluis E.; Baucells, Jordi; Cugat, Xavier; Álvaro, Tomás; Jaén, Joaquín

    2008-01-01

    This study investigates the effects of digital image compression on automatic quantification of immunohistochemical nuclear markers. We examined 188 images with a previously validated computer-assisted analysis system. A first group was composed of 47 images captured in TIFF format, and other three contained the same images converted from TIFF to JPEG format with 3×, 23× and 46× compression. Counts of TIFF format images were compared with the other three groups. Overall, differences in the count of the images increased with the percentage of compression. Low-complexity images (≤100 cells/field, without clusters or with small-area clusters) had small differences (<5 cells/field in 95–100% of cases) and high-complexity images showed substantial differences (<35–50 cells/field in 95–100% of cases). Compression does not compromise the accuracy of immunohistochemical nuclear marker counts obtained by computer-assisted analysis systems for digital images with low complexity and could be an efficient method for storing these images. PMID:18755997

  19. Liver CT image processing: a short introduction of the technical elements.

    PubMed

    Masutani, Y; Uozumi, K; Akahane, Masaaki; Ohtomo, Kuni

    2006-05-01

    In this paper, we describe the technical aspects of image analysis for liver diagnosis and treatment, including the state-of-the-art of liver image analysis and its applications. After discussion on modalities for liver image analysis, various technical elements for liver image analysis such as registration, segmentation, modeling, and computer-assisted detection are covered with examples performed with clinical data sets. Perspective in the imaging technologies is also reviewed and discussed.

  20. Computer-Assisted Analysis of Near-Bottom Photos for Benthic Habitat Studies

    DTIC Science & Technology

    2006-09-01

    navigated survey platform greatly increases the efficiency of image analysis and provides new insight about the relationships between benthic organisms...increase in the efficiency of image analysis for benthic habitat studies, and provides the opportunity to assess small scale spatial distribution of

  1. The computer treatment of remotely sensed data: An introduction to techniques which have geologic applications. [image enhancement and thematic classification in Brazil

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Paradella, W. R.; Vitorello, I.

    1982-01-01

    Several aspects of computer-assisted analysis techniques for image enhancement and thematic classification by which LANDSAT MSS imagery may be treated quantitatively are explained. On geological applications, computer processing of digital data allows, possibly, the fullest use of LANDSAT data, by displaying enhanced and corrected data for visual analysis and by evaluating and assigning each spectral pixel information to a given class.

  2. Image analysis in modern ophthalmology: from acquisition to computer assisted diagnosis and telemedicine

    NASA Astrophysics Data System (ADS)

    Marrugo, Andrés G.; Millán, María S.; Cristóbal, Gabriel; Gabarda, Salvador; Sorel, Michal; Sroubek, Filip

    2012-06-01

    Medical digital imaging has become a key element of modern health care procedures. It provides visual documentation and a permanent record for the patients, and most important the ability to extract information about many diseases. Modern ophthalmology thrives and develops on the advances in digital imaging and computing power. In this work we present an overview of recent image processing techniques proposed by the authors in the area of digital eye fundus photography. Our applications range from retinal image quality assessment to image restoration via blind deconvolution and visualization of structural changes in time between patient visits. All proposed within a framework for improving and assisting the medical practice and the forthcoming scenario of the information chain in telemedicine.

  3. Computer assisted analysis of medical x-ray images

    NASA Astrophysics Data System (ADS)

    Bengtsson, Ewert

    1996-01-01

    X-rays were originally used to expose film. The early computers did not have enough capacity to handle images with useful resolution. The rapid development of computer technology over the last few decades has, however, led to the introduction of computers into radiology. In this overview paper, the various possible roles of computers in radiology are examined. The state of the art is briefly presented, and some predictions about the future are made.

  4. Development and application of operational techniques for the inventory and monitoring of resources and uses for the Texas coastal zone

    NASA Technical Reports Server (NTRS)

    Harwood, P. (Principal Investigator); Malin, P.; Finley, R.; Mcculloch, S.; Murphy, D.; Hupp, B.; Schell, J. A.

    1977-01-01

    The author has identified the following significant results. Four LANDSAT scenes were analyzed for the Harbor Island area test sites to produce land cover and land use maps using both image interpretation and computer-assisted techniques. When evaluated against aerial photography, the mean accuracy for three scenes was 84% for the image interpretation product and 62% for the computer-assisted classification maps. Analysis of the fourth scene was not completed using the image interpretation technique, because of poor quality, false color composite, but was available from the computer technique. Preliminary results indicate that these LANDSAT products can be applied to a variety of planning and management activities in the Texas coastal zone.

  5. Low-cost digital image processing at the University of Oklahoma

    NASA Technical Reports Server (NTRS)

    Harrington, J. A., Jr.

    1981-01-01

    Computer assisted instruction in remote sensing at the University of Oklahoma involves two separate approaches and is dependent upon initial preprocessing of a LANDSAT computer compatible tape using software developed for an IBM 370/158 computer. In-house generated preprocessing algorithms permits students or researchers to select a subset of a LANDSAT scene for subsequent analysis using either general purpose statistical packages or color graphic image processing software developed for Apple II microcomputers. Procedures for preprocessing the data and image analysis using either of the two approaches for low-cost LANDSAT data processing are described.

  6. Promise of new imaging technologies for assessing ovarian function.

    PubMed

    Singh, Jaswant; Adams, Gregg P; Pierson, Roger A

    2003-10-15

    Advancements in imaging technologies over the last two decades have ushered a quiet revolution in research approaches to the study of ovarian structure and function. The most significant changes in our understanding of the ovary have resulted from the use of ultrasonography which has enabled sequential analyses in live animals. Computer-assisted image analysis and mathematical modeling of the dynamic changes within the ovary has permitted exciting new avenues of research with readily quantifiable endpoints. Spectral, color-flow and power Doppler imaging now facilitate physiologic interpretations of vascular dynamics over time. Similarly, magnetic resonance imaging (MRI) is emerging as a research tool in ovarian imaging. New technologies, such as three-dimensional ultrasonography and MRI, ultrasound-based biomicroscopy and synchrotron-based techniques each have the potential to enhance our real-time picture of ovarian function to the near-cellular level. Collectively, information available in ultrasonography, MRI, computer-assisted image analysis and mathematical modeling heralds a new era in our understanding of the basic processes of female and male reproduction.

  7. Radiomic analysis in prediction of Human Papilloma Virus status.

    PubMed

    Yu, Kaixian; Zhang, Youyi; Yu, Yang; Huang, Chao; Liu, Rongjie; Li, Tengfei; Yang, Liuqing; Morris, Jeffrey S; Baladandayuthapani, Veerabhadran; Zhu, Hongtu

    2017-12-01

    Human Papilloma Virus (HPV) has been associated with oropharyngeal cancer prognosis. Traditionally the HPV status is tested through invasive lab test. Recently, the rapid development of statistical image analysis techniques has enabled precise quantitative analysis of medical images. The quantitative analysis of Computed Tomography (CT) provides a non-invasive way to assess HPV status for oropharynx cancer patients. We designed a statistical radiomics approach analyzing CT images to predict HPV status. Various radiomics features were extracted from CT scans, and analyzed using statistical feature selection and prediction methods. Our approach ranked the highest in the 2016 Medical Image Computing and Computer Assisted Intervention (MICCAI) grand challenge: Oropharynx Cancer (OPC) Radiomics Challenge, Human Papilloma Virus (HPV) Status Prediction. Further analysis on the most relevant radiomic features distinguishing HPV positive and negative subjects suggested that HPV positive patients usually have smaller and simpler tumors.

  8. Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions.

    PubMed

    Zhang, Xue; Xiao, Yang; Zeng, Jie; Qiu, Weibao; Qian, Ming; Wang, Congzhi; Zheng, Rongqin; Zheng, Hairong

    2014-01-01

    To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (Az value) for the proposed method was higher than the Az value for visual assessment (0.96 vs. 0.93). Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Progress in analysis of computed tomography (CT) images of hardwood logs for defect detection

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2003-01-01

    This paper addresses the problem of automatically detecting internal defects in logs using computed tomography (CT) images. The overall purpose is to assist in breakdown optimization. Several studies have shown that the commercial value of resulting boards can be increased substantially if defect locations are known in advance, and if this information is used to make...

  10. Automated analysis and classification of melanocytic tumor on skin whole slide images.

    PubMed

    Xu, Hongming; Lu, Cheng; Berendt, Richard; Jha, Naresh; Mandal, Mrinal

    2018-06-01

    This paper presents a computer-aided technique for automated analysis and classification of melanocytic tumor on skin whole slide biopsy images. The proposed technique consists of four main modules. First, skin epidermis and dermis regions are segmented by a multi-resolution framework. Next, epidermis analysis is performed, where a set of epidermis features reflecting nuclear morphologies and spatial distributions is computed. In parallel with epidermis analysis, dermis analysis is also performed, where dermal cell nuclei are segmented and a set of textural and cytological features are computed. Finally, the skin melanocytic image is classified into different categories such as melanoma, nevus or normal tissue by using a multi-class support vector machine (mSVM) with extracted epidermis and dermis features. Experimental results on 66 skin whole slide images indicate that the proposed technique achieves more than 95% classification accuracy, which suggests that the technique has the potential to be used for assisting pathologists on skin biopsy image analysis and classification. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device.

    PubMed

    Burgreen, Greg W; Loree, Howard M; Bourque, Kevin; Dague, Charles; Poirier, Victor L; Farrar, David; Hampton, Edward; Wu, Z Jon; Gempp, Thomas M; Schöb, Reto

    2004-10-01

    The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of physiological operating conditions. The HeartMate III is a centrifugal flow pump with a magnetically suspended rotor. The complete pump was analyzed using computational fluid dynamics (CFD) analysis and experimental particle imaging flow visualization (PIFV). A comparison of CFD predictions to experimental imaging shows good agreement. Both CFD and experimental PIFV confirmed well-behaved flow fields in the main components of the HeartMate III pump: inlet, volute, and outlet. The HeartMate III is shown to exhibit clean flow features and good surface washing across its entire operating range.

  12. A comparative study of 2 computer-assisted methods of quantifying brightfield microscopy images.

    PubMed

    Tse, George H; Marson, Lorna P

    2013-10-01

    Immunohistochemistry continues to be a powerful tool for the detection of antigens. There are several commercially available software packages that allow image analysis; however, these can be complex, require relatively high level of computer skills, and can be expensive. We compared 2 commonly available software packages, Adobe Photoshop CS6 and ImageJ, in their ability to quantify percentage positive area after picrosirius red (PSR) staining and 3,3'-diaminobenzidine (DAB) staining. On analysis of DAB-stained B cells in the mouse spleen, with a biotinylated primary rat anti-mouse-B220 antibody, there was no significant difference on converting images from brightfield microscopy to binary images to measure black and white pixels using ImageJ compared with measuring a range of brown pixels with Photoshop (Student t test, P=0.243, correlation r=0.985). When analyzing mouse kidney allografts stained with PSR, Photoshop achieved a greater interquartile range while maintaining a lower 10th percentile value compared with analysis with ImageJ. A lower 10% percentile reflects that Photoshop analysis is better at analyzing tissues with low levels of positive pixels; particularly relevant for control tissues or negative controls, whereas after ImageJ analysis the same images would result in spuriously high levels of positivity. Furthermore comparing the 2 methods by Bland-Altman plot revealed that these 2 methodologies did not agree when measuring images with a higher percentage of positive staining and correlation was poor (r=0.804). We conclude that for computer-assisted analysis of images of DAB-stained tissue there is no difference between using Photoshop or ImageJ. However, for analysis of color images where differentiation into a binary pattern is not easy, such as with PSR, Photoshop is superior at identifying higher levels of positivity while maintaining differentiation of low levels of positive staining.

  13. The use of computer-assisted image analysis in the evaluation of the effect of management systems on changes in the color, chemical composition and texture of m. longissimus dorsi in pigs.

    PubMed

    Zapotoczny, Piotr; Kozera, Wojciech; Karpiesiuk, Krzysztof; Pawłowski, Rodian

    2014-08-01

    The effect of management systems on selected physical properties and chemical composition of m. longissimus dorsi was studied in pigs. Muscle texture parameters were determined by computer-assisted image analysis, and the color of muscle samples was evaluated using a spectrophotometer. Highly significant correlations were observed between chemical composition and selected texture variables in the analyzed images. Chemical composition was not correlated with color or spectral distribution. Subject to the applied classification methods and groups of variables included in the classification model, the experimental groups were identified correctly in 35-95%. No significant differences in the chemical composition of m. longissimus dorsi were observed between experimental groups. Significant differences were noted in color lightness (L*) and redness (a*). Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  15. Deep Learning in Medical Image Analysis.

    PubMed

    Shen, Dinggang; Wu, Guorong; Suk, Heung-Il

    2017-06-21

    This review covers computer-assisted analysis of images in the field of medical imaging. Recent advances in machine learning, especially with regard to deep learning, are helping to identify, classify, and quantify patterns in medical images. At the core of these advances is the ability to exploit hierarchical feature representations learned solely from data, instead of features designed by hand according to domain-specific knowledge. Deep learning is rapidly becoming the state of the art, leading to enhanced performance in various medical applications. We introduce the fundamentals of deep learning methods and review their successes in image registration, detection of anatomical and cellular structures, tissue segmentation, computer-aided disease diagnosis and prognosis, and so on. We conclude by discussing research issues and suggesting future directions for further improvement.

  16. Qualitative and quantitative interpretation of SEM image using digital image processing.

    PubMed

    Saladra, Dawid; Kopernik, Magdalena

    2016-10-01

    The aim of the this study is improvement of qualitative and quantitative analysis of scanning electron microscope micrographs by development of computer program, which enables automatic crack analysis of scanning electron microscopy (SEM) micrographs. Micromechanical tests of pneumatic ventricular assist devices result in a large number of micrographs. Therefore, the analysis must be automatic. Tests for athrombogenic titanium nitride/gold coatings deposited on polymeric substrates (Bionate II) are performed. These tests include microshear, microtension and fatigue analysis. Anisotropic surface defects observed in the SEM micrographs require support for qualitative and quantitative interpretation. Improvement of qualitative analysis of scanning electron microscope images was achieved by a set of computational tools that includes binarization, simplified expanding, expanding, simple image statistic thresholding, the filters Laplacian 1, and Laplacian 2, Otsu and reverse binarization. Several modifications of the known image processing techniques and combinations of the selected image processing techniques were applied. The introduced quantitative analysis of digital scanning electron microscope images enables computation of stereological parameters such as area, crack angle, crack length, and total crack length per unit area. This study also compares the functionality of the developed computer program of digital image processing with existing applications. The described pre- and postprocessing may be helpful in scanning electron microscopy and transmission electron microscopy surface investigations. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  17. Development of an assisting detection system for early infarct diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sim, K. S.; Nia, M. E.; Ee, C. S.

    2015-04-24

    In this paper, a detection assisting system for early infarct detection is developed. This new developed method is used to assist the medical practitioners to diagnose infarct from computed tomography images of brain. Using this assisting system, the infarct could be diagnosed at earlier stages. The non-contrast computed tomography (NCCT) brain images are the data set used for this system. Detection module extracts the pixel data from NCCT brain images, and produces the colourized version of images. The proposed method showed great potential in detecting infarct, and helps medical practitioners to make earlier and better diagnoses.

  18. Software phantom with realistic speckle modeling for validation of image analysis methods in echocardiography

    NASA Astrophysics Data System (ADS)

    Law, Yuen C.; Tenbrinck, Daniel; Jiang, Xiaoyi; Kuhlen, Torsten

    2014-03-01

    Computer-assisted processing and interpretation of medical ultrasound images is one of the most challenging tasks within image analysis. Physical phenomena in ultrasonographic images, e.g., the characteristic speckle noise and shadowing effects, make the majority of standard methods from image analysis non optimal. Furthermore, validation of adapted computer vision methods proves to be difficult due to missing ground truth information. There is no widely accepted software phantom in the community and existing software phantoms are not exible enough to support the use of specific speckle models for different tissue types, e.g., muscle and fat tissue. In this work we propose an anatomical software phantom with a realistic speckle pattern simulation to _ll this gap and provide a exible tool for validation purposes in medical ultrasound image analysis. We discuss the generation of speckle patterns and perform statistical analysis of the simulated textures to obtain quantitative measures of the realism and accuracy regarding the resulting textures.

  19. On the importance of mathematical methods for analysis of MALDI-imaging mass spectrometry data.

    PubMed

    Trede, Dennis; Kobarg, Jan Hendrik; Oetjen, Janina; Thiele, Herbert; Maass, Peter; Alexandrov, Theodore

    2012-03-21

    In the last decade, matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS), also called as MALDI-imaging, has proven its potential in proteomics and was successfully applied to various types of biomedical problems, in particular to histopathological label-free analysis of tissue sections. In histopathology, MALDI-imaging is used as a general analytic tool revealing the functional proteomic structure of tissue sections, and as a discovery tool for detecting new biomarkers discriminating a region annotated by an experienced histologist, in particular, for cancer studies. A typical MALDI-imaging data set contains 10⁸ to 10⁹ intensity values occupying more than 1 GB. Analysis and interpretation of such huge amount of data is a mathematically, statistically and computationally challenging problem. In this paper we overview some computational methods for analysis of MALDI-imaging data sets. We discuss the importance of data preprocessing, which typically includes normalization, baseline removal and peak picking, and hightlight the importance of image denoising when visualizing IMS data.

  20. On the Importance of Mathematical Methods for Analysis of MALDI-Imaging Mass Spectrometry Data.

    PubMed

    Trede, Dennis; Kobarg, Jan Hendrik; Oetjen, Janina; Thiele, Herbert; Maass, Peter; Alexandrov, Theodore

    2012-03-01

    In the last decade, matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS), also called as MALDI-imaging, has proven its potential in proteomics and was successfully applied to various types of biomedical problems, in particular to histopathological label-free analysis of tissue sections. In histopathology, MALDI-imaging is used as a general analytic tool revealing the functional proteomic structure of tissue sections, and as a discovery tool for detecting new biomarkers discriminating a region annotated by an experienced histologist, in particular, for cancer studies. A typical MALDI-imaging data set contains 108 to 109 intensity values occupying more than 1 GB. Analysis and interpretation of such huge amount of data is a mathematically, statistically and computationally challenging problem. In this paper we overview some computational methods for analysis of MALDI-imaging data sets. We discuss the importance of data preprocessing, which typically includes normalization, baseline removal and peak picking, and hightlight the importance of image denoising when visualizing IMS data.

  1. Diagnosis of cutaneous thermal burn injuries by multispectral imaging analysis

    NASA Technical Reports Server (NTRS)

    Anselmo, V. J.; Zawacki, B. E.

    1978-01-01

    Special photographic or television image analysis is shown to be a potentially useful technique to assist the physician in the early diagnosis of thermal burn injury. A background on the medical and physiological problems of burns is presented. The proposed methodology for burns diagnosis from both the theoretical and clinical points of view is discussed. The television/computer system constructed to accomplish this analysis is described, and the clinical results are discussed.

  2. Computer-assisted segmentation of white matter lesions in 3D MR images using support vector machine.

    PubMed

    Lao, Zhiqiang; Shen, Dinggang; Liu, Dengfeng; Jawad, Abbas F; Melhem, Elias R; Launer, Lenore J; Bryan, R Nick; Davatzikos, Christos

    2008-03-01

    Brain lesions, especially white matter lesions (WMLs), are associated with cardiac and vascular disease, but also with normal aging. Quantitative analysis of WML in large clinical trials is becoming more and more important. In this article, we present a computer-assisted WML segmentation method, based on local features extracted from multiparametric magnetic resonance imaging (MRI) sequences (ie, T1-weighted, T2-weighted, proton density-weighted, and fluid attenuation inversion recovery MRI scans). A support vector machine classifier is first trained on expert-defined WMLs, and is then used to classify new scans. Postprocessing analysis further reduces false positives by using anatomic knowledge and measures of distance from the training set. Cross-validation on a population of 35 patients from three different imaging sites with WMLs of varying sizes, shapes, and locations tests the robustness and accuracy of the proposed segmentation method, compared with the manual segmentation results from two experienced neuroradiologists.

  3. Developing Understanding of Image Formation by Lenses through Collaborative Learning Mediated by Multimedia Computer-Assisted Learning Programs

    ERIC Educational Resources Information Center

    Tao, Ping-Kee

    2004-01-01

    This article reports the use of a computer-based collaborative learning instruction designed to help students develop understanding of image formation by lenses. The study aims to investigate how students, working in dyads and mediated by multimedia computer-assisted learning (CAL) programs, construct shared knowledge and understanding. The…

  4. Personalized, relevance-based Multimodal Robotic Imaging and augmented reality for Computer Assisted Interventions.

    PubMed

    Navab, Nassir; Fellow, Miccai; Hennersperger, Christoph; Frisch, Benjamin; Fürst, Bernhard

    2016-10-01

    In the last decade, many researchers in medical image computing and computer assisted interventions across the world focused on the development of the Virtual Physiological Human (VPH), aiming at changing the practice of medicine from classification and treatment of diseases to that of modeling and treating patients. These projects resulted in major advancements in segmentation, registration, morphological, physiological and biomechanical modeling based on state of art medical imaging as well as other sensory data. However, a major issue which has not yet come into the focus is personalizing intra-operative imaging, allowing for optimal treatment. In this paper, we discuss the personalization of imaging and visualization process with particular focus on satisfying the challenging requirements of computer assisted interventions. We discuss such requirements and review a series of scientific contributions made by our research team to tackle some of these major challenges. Copyright © 2016. Published by Elsevier B.V.

  5. Multiscale hidden Markov models for photon-limited imaging

    NASA Astrophysics Data System (ADS)

    Nowak, Robert D.

    1999-06-01

    Photon-limited image analysis is often hindered by low signal-to-noise ratios. A novel Bayesian multiscale modeling and analysis method is developed in this paper to assist in these challenging situations. In addition to providing a very natural and useful framework for modeling an d processing images, Bayesian multiscale analysis is often much less computationally demanding compared to classical Markov random field models. This paper focuses on a probabilistic graph model called the multiscale hidden Markov model (MHMM), which captures the key inter-scale dependencies present in natural image intensities. The MHMM framework presented here is specifically designed for photon-limited imagin applications involving Poisson statistics, and applications to image intensity analysis are examined.

  6. Accessible microscopy workstation for students and scientists with mobility impairments.

    PubMed

    Duerstock, Bradley S

    2006-01-01

    An integrated accessible microscopy workstation was designed and developed to allow persons with mobility impairments to control all aspects of light microscopy with minimal human assistance. This system, named AccessScope, is capable of performing brightfield and fluorescence microscopy, image analysis, and tissue morphometry requisite for undergraduate science courses to graduate-level research. An accessible microscope is necessary for students and scientists with mobility impairments to be able to use a microscope independently to better understand microscopical imaging concepts and cell biology. This knowledge is not always apparent by simply viewing a catalog of histological images. The ability to operate a microscope independently eliminates the need to hire an assistant or rely on a classmate and permits one to take practical laboratory examinations by oneself. Independent microscope handling is also crucial for graduate students and scientists with disabilities to perform scientific research. By making a personal computer as the user interface for controlling AccessScope functions, different upper limb mobility impairments could be accommodated by using various computer input devices and assistive technology software. Participants with a range of upper limb mobility impairments evaluated the prototype microscopy workstation. They were able to control all microscopy functions including loading different slides without assistance.

  7. Computer-assisted liver graft steatosis assessment via learning-based texture analysis.

    PubMed

    Moccia, Sara; Mattos, Leonardo S; Patrini, Ilaria; Ruperti, Michela; Poté, Nicolas; Dondero, Federica; Cauchy, François; Sepulveda, Ailton; Soubrane, Olivier; De Momi, Elena; Diaspro, Alberto; Cesaretti, Manuela

    2018-05-23

    Fast and accurate graft hepatic steatosis (HS) assessment is of primary importance for lowering liver dysfunction risks after transplantation. Histopathological analysis of biopsied liver is the gold standard for assessing HS, despite being invasive and time consuming. Due to the short time availability between liver procurement and transplantation, surgeons perform HS assessment through clinical evaluation (medical history, blood tests) and liver texture visual analysis. Despite visual analysis being recognized as challenging in the clinical literature, few efforts have been invested to develop computer-assisted solutions for HS assessment. The objective of this paper is to investigate the automatic analysis of liver texture with machine learning algorithms to automate the HS assessment process and offer support for the surgeon decision process. Forty RGB images of forty different donors were analyzed. The images were captured with an RGB smartphone camera in the operating room (OR). Twenty images refer to livers that were accepted and 20 to discarded livers. Fifteen randomly selected liver patches were extracted from each image. Patch size was [Formula: see text]. This way, a balanced dataset of 600 patches was obtained. Intensity-based features (INT), histogram of local binary pattern ([Formula: see text]), and gray-level co-occurrence matrix ([Formula: see text]) were investigated. Blood-sample features (Blo) were included in the analysis, too. Supervised and semisupervised learning approaches were investigated for feature classification. The leave-one-patient-out cross-validation was performed to estimate the classification performance. With the best-performing feature set ([Formula: see text]) and semisupervised learning, the achieved classification sensitivity, specificity, and accuracy were 95, 81, and 88%, respectively. This research represents the first attempt to use machine learning and automatic texture analysis of RGB images from ubiquitous smartphone cameras for the task of graft HS assessment. The results suggest that is a promising strategy to develop a fully automatic solution to assist surgeons in HS assessment inside the OR.

  8. Deep Learning in Medical Image Analysis

    PubMed Central

    Shen, Dinggang; Wu, Guorong; Suk, Heung-Il

    2016-01-01

    The computer-assisted analysis for better interpreting images have been longstanding issues in the medical imaging field. On the image-understanding front, recent advances in machine learning, especially, in the way of deep learning, have made a big leap to help identify, classify, and quantify patterns in medical images. Specifically, exploiting hierarchical feature representations learned solely from data, instead of handcrafted features mostly designed based on domain-specific knowledge, lies at the core of the advances. In that way, deep learning is rapidly proving to be the state-of-the-art foundation, achieving enhanced performances in various medical applications. In this article, we introduce the fundamentals of deep learning methods; review their successes to image registration, anatomical/cell structures detection, tissue segmentation, computer-aided disease diagnosis or prognosis, and so on. We conclude by raising research issues and suggesting future directions for further improvements. PMID:28301734

  9. Evaluation of browning ratio in an image analysis of apple slices at different stages of instant controlled pressure drop-assisted hot-air drying (AD-DIC).

    PubMed

    Gao, Kun; Zhou, Linyan; Bi, Jinfeng; Yi, Jianyong; Wu, Xinye; Zhou, Mo; Wang, Xueyuan; Liu, Xuan

    2017-06-01

    Computer vision-based image analysis systems are widely used in food processing to evaluate quality changes. They are able to objectively measure the surface colour of various products since, providing some obvious advantages with their objectivity and quantitative capabilities. In this study, a computer vision-based image analysis system was used to investigate the colour changes of apple slices dried by instant controlled pressure drop-assisted hot air drying (AD-DIC). The CIE L* value and polyphenol oxidase activity in apple slices decreased during the entire drying process, whereas other colour indexes, including CIE a*, b*, ΔE and C* values, increased. The browning ratio calculated by image analysis increased during the drying process, and a sharp increment was observed for the DIC process. The change in 5-hydroxymethylfurfural (5-HMF) and fluorescent compounds (FIC) showed the same trend with browning ratio due to Maillard reaction. Moreover, the concentrations of 5-HMF and FIC both had a good quadratic correlation (R 2  > 0.998) with the browning ratio. Browning ratio was a reliable indicator of 5-HMF and FIC changes in apple slices during drying. The image analysis system could be used to monitor colour changes, 5-HMF and FIC in dehydrated apple slices during the AD-DIC process. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  10. Texture classification of lung computed tomography images

    NASA Astrophysics Data System (ADS)

    Pheng, Hang See; Shamsuddin, Siti M.

    2013-03-01

    Current development of algorithms in computer-aided diagnosis (CAD) scheme is growing rapidly to assist the radiologist in medical image interpretation. Texture analysis of computed tomography (CT) scans is one of important preliminary stage in the computerized detection system and classification for lung cancer. Among different types of images features analysis, Haralick texture with variety of statistical measures has been used widely in image texture description. The extraction of texture feature values is essential to be used by a CAD especially in classification of the normal and abnormal tissue on the cross sectional CT images. This paper aims to compare experimental results using texture extraction and different machine leaning methods in the classification normal and abnormal tissues through lung CT images. The machine learning methods involve in this assessment are Artificial Immune Recognition System (AIRS), Naive Bayes, Decision Tree (J48) and Backpropagation Neural Network. AIRS is found to provide high accuracy (99.2%) and sensitivity (98.0%) in the assessment. For experiments and testing purpose, publicly available datasets in the Reference Image Database to Evaluate Therapy Response (RIDER) are used as study cases.

  11. From computer-assisted intervention research to clinical impact: The need for a holistic approach.

    PubMed

    Ourselin, Sébastien; Emberton, Mark; Vercauteren, Tom

    2016-10-01

    The early days of the field of medical image computing (MIC) and computer-assisted intervention (CAI), when publishing a strong self-contained methodological algorithm was enough to produce impact, are over. As a community, we now have substantial responsibility to translate our scientific progresses into improved patient care. In the field of computer-assisted interventions, the emphasis is also shifting from the mere use of well-known established imaging modalities and position trackers to the design and combination of innovative sensing, elaborate computational models and fine-grained clinical workflow analysis to create devices with unprecedented capabilities. The barriers to translating such devices in the complex and understandably heavily regulated surgical and interventional environment can seem daunting. Whether we leave the translation task mostly to our industrial partners or welcome, as researchers, an important share of it is up to us. We argue that embracing the complexity of surgical and interventional sciences is mandatory to the evolution of the field. Being able to do so requires large-scale infrastructure and a critical mass of expertise that very few research centres have. In this paper, we emphasise the need for a holistic approach to computer-assisted interventions where clinical, scientific, engineering and regulatory expertise are combined as a means of moving towards clinical impact. To ensure that the breadth of infrastructure and expertise required for translational computer-assisted intervention research does not lead to a situation where the field advances only thanks to a handful of exceptionally large research centres, we also advocate that solutions need to be designed to lower the barriers to entry. Inspired by fields such as particle physics and astronomy, we claim that centralised very large innovation centres with state of the art technology and health technology assessment capabilities backed by core support staff and open interoperability standards need to be accessible to the wider computer-assisted intervention research community. Copyright © 2016. Published by Elsevier B.V.

  12. Radiology's Achilles' heel: error and variation in the interpretation of the Röntgen image.

    PubMed

    Robinson, P J

    1997-11-01

    The performance of the human eye and brain has failed to keep pace with the enormous technical progress in the first full century of radiology. Errors and variations in interpretation now represent the weakest aspect of clinical imaging. Those interpretations which differ from the consensus view of a panel of "experts" may be regarded as errors; where experts fail to achieve consensus, differing reports are regarded as "observer variation". Errors arise from poor technique, failures of perception, lack of knowledge and misjudgments. Observer variation is substantial and should be taken into account when different diagnostic methods are compared; in many cases the difference between observers outweighs the difference between techniques. Strategies for reducing error include attention to viewing conditions, training of the observers, availability of previous films and relevant clinical data, dual or multiple reporting, standardization of terminology and report format, and assistance from computers. Digital acquisition and display will probably not affect observer variation but the performance of radiologists, as measured by receiver operating characteristic (ROC) analysis, may be improved by computer-directed search for specific image features. Other current developments show that where image features can be comprehensively described, computer analysis can replace the perception function of the observer, whilst the function of interpretation can in some cases be performed better by artificial neural networks. However, computer-assisted diagnosis is still in its infancy and complete replacement of the human observer is as yet a remote possibility.

  13. Analysis of components of variance in multiple-reader studies of computer-aided diagnosis with different tasks

    NASA Astrophysics Data System (ADS)

    Beiden, Sergey V.; Wagner, Robert F.; Campbell, Gregory; Metz, Charles E.; Chan, Heang-Ping; Nishikawa, Robert M.; Schnall, Mitchell D.; Jiang, Yulei

    2001-06-01

    In recent years, the multiple-reader, multiple-case (MRMC) study paradigm has become widespread for receiver operating characteristic (ROC) assessment of systems for diagnostic imaging and computer-aided diagnosis. We review how MRMC data can be analyzed in terms of the multiple components of the variance (case, reader, interactions) observed in those studies. Such information is useful for the design of pivotal studies from results of a pilot study and also for studying the effects of reader training. Recently, several of the present authors have demonstrated methods to generalize the analysis of multiple variance components to the case where unaided readers of diagnostic images are compared with readers who receive the benefit of a computer assist (CAD). For this case it is necessary to model the possibility that several of the components of variance might be reduced when readers incorporate the computer assist, compared to the unaided reading condition. We review results of this kind of analysis on three previously published MRMC studies, two of which were applications of CAD to diagnostic mammography and one was an application of CAD to screening mammography. The results for the three cases are seen to differ, depending on the reader population sampled and the task of interest. Thus, it is not possible to generalize a particular analysis of variance components beyond the tasks and populations actually investigated.

  14. ImagePy: an open-source, Python-based and platform-independent software package for boimage analysis.

    PubMed

    Wang, Anliang; Yan, Xiaolong; Wei, Zhijun

    2018-04-27

    This note presents the design of a scalable software package named ImagePy for analysing biological images. Our contribution is concentrated on facilitating extensibility and interoperability of the software through decoupling the data model from the user interface. Especially with assistance from the Python ecosystem, this software framework makes modern computer algorithms easier to be applied in bioimage analysis. ImagePy is free and open source software, with documentation and code available at https://github.com/Image-Py/imagepy under the BSD license. It has been tested on the Windows, Mac and Linux operating systems. wzjdlut@dlut.edu.cn or yxdragon@imagepy.org.

  15. Neural networks: Application to medical imaging

    NASA Technical Reports Server (NTRS)

    Clarke, Laurence P.

    1994-01-01

    The research mission is the development of computer assisted diagnostic (CAD) methods for improved diagnosis of medical images including digital x-ray sensors and tomographic imaging modalities. The CAD algorithms include advanced methods for adaptive nonlinear filters for image noise suppression, hybrid wavelet methods for feature segmentation and enhancement, and high convergence neural networks for feature detection and VLSI implementation of neural networks for real time analysis. Other missions include (1) implementation of CAD methods on hospital based picture archiving computer systems (PACS) and information networks for central and remote diagnosis and (2) collaboration with defense and medical industry, NASA, and federal laboratories in the area of dual use technology conversion from defense or aerospace to medicine.

  16. Analysis of objects in binary images. M.S. Thesis - Old Dominion Univ.

    NASA Technical Reports Server (NTRS)

    Leonard, Desiree M.

    1991-01-01

    Digital image processing techniques are typically used to produce improved digital images through the application of successive enhancement techniques to a given image or to generate quantitative data about the objects within that image. In support of and to assist researchers in a wide range of disciplines, e.g., interferometry, heavy rain effects on aerodynamics, and structure recognition research, it is often desirable to count objects in an image and compute their geometric properties. Therefore, an image analysis application package, focusing on a subset of image analysis techniques used for object recognition in binary images, was developed. This report describes the techniques and algorithms utilized in three main phases of the application and are categorized as: image segmentation, object recognition, and quantitative analysis. Appendices provide supplemental formulas for the algorithms employed as well as examples and results from the various image segmentation techniques and the object recognition algorithm implemented.

  17. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model.

    PubMed

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole; Pedersen, Bodil Ginnerup; Andersen, Gratien; Høyer, Søren; Borre, Michael

    2017-08-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention, each animal was randomized to a postoperative follow-up period of 1, 2, or 4 weeks, after which computed tomography perfusion and magnetic resonance imaging scans were performed. Immediately after imaging, open bilateral nephrectomy was performed allowing for histopathological examination of the cryolesions. On computed tomography perfusion and magnetic resonance imaging examinations, rim enhancement was observed in the transition zone of the cryolesion 1week after laparoscopic-assisted cryoablation. This rim enhancement was found to subside after 2 and 4 weeks of follow-up, which was consistent with the microscopic examinations revealing of fibrotic scar tissue formation in the peripheral zone of the cryolesion. On T2 magnetic resonance imaging sequences, a thin hypointense rim surrounded the cryolesion, separating it from the adjacent renal parenchyma. Microscopic examinations revealed hemorrhage and later hemosiderin located in the peripheral zone. No nodular or diffuse contrast enhancement was found in the central zone of the cryolesions at any follow-up stage on neither computed tomography perfusion nor magnetic resonance imaging. On microscopic examinations, the central zone was found to consist of coagulative necrosis 1 week after laparoscopic-assisted cryoablation, which was partially replaced by fibrotic scar tissue 4 weeks following laparoscopic-assisted cryoablation. Both computed tomography perfusion and magnetic resonance imaging found the renal collecting system to be involved at all 3 stages of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings but with some differences, especially regarding the peripheral zone. Magnetic resonance imaging seems an attractive modality for early postoperative follow-up.

  18. [Basic concept in computer assisted surgery].

    PubMed

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  19. Fast Image Texture Classification Using Decision Trees

    NASA Technical Reports Server (NTRS)

    Thompson, David R.

    2011-01-01

    Texture analysis would permit improved autonomous, onboard science data interpretation for adaptive navigation, sampling, and downlink decisions. These analyses would assist with terrain analysis and instrument placement in both macroscopic and microscopic image data products. Unfortunately, most state-of-the-art texture analysis demands computationally expensive convolutions of filters involving many floating-point operations. This makes them infeasible for radiation- hardened computers and spaceflight hardware. A new method approximates traditional texture classification of each image pixel with a fast decision-tree classifier. The classifier uses image features derived from simple filtering operations involving integer arithmetic. The texture analysis method is therefore amenable to implementation on FPGA (field-programmable gate array) hardware. Image features based on the "integral image" transform produce descriptive and efficient texture descriptors. Training the decision tree on a set of training data yields a classification scheme that produces reasonable approximations of optimal "texton" analysis at a fraction of the computational cost. A decision-tree learning algorithm employing the traditional k-means criterion of inter-cluster variance is used to learn tree structure from training data. The result is an efficient and accurate summary of surface morphology in images. This work is an evolutionary advance that unites several previous algorithms (k-means clustering, integral images, decision trees) and applies them to a new problem domain (morphology analysis for autonomous science during remote exploration). Advantages include order-of-magnitude improvements in runtime, feasibility for FPGA hardware, and significant improvements in texture classification accuracy.

  20. Computer-assisted learning in anatomy at the international medical school in Debrecen, Hungary: a preliminary report.

    PubMed

    Kish, Gary; Cook, Samuel A; Kis, Gréta

    2013-01-01

    The University of Debrecen's Faculty of Medicine has an international, multilingual student population with anatomy courses taught in English to all but Hungarian students. An elective computer-assisted gross anatomy course, the Computer Human Anatomy (CHA), has been taught in English at the Anatomy Department since 2008. This course focuses on an introduction to anatomical digital images along with clinical cases. This low-budget course has a large visual component using images from magnetic resonance imaging and computer axial tomogram scans, ultrasound clinical studies, and readily available anatomy software that presents topics which run in parallel to the university's core anatomy curriculum. From the combined computer images and CHA lecture information, students are asked to solve computer-based clinical anatomy problems in the CHA computer laboratory. A statistical comparison was undertaken of core anatomy oral examination performances of English program first-year medical students who took the elective CHA course and those who did not in the three academic years 2007-2008, 2008-2009, and 2009-2010. The results of this study indicate that the CHA-enrolled students improved their performance on required anatomy core curriculum oral examinations (P < 0.001), suggesting that computer-assisted learning may play an active role in anatomy curriculum improvement. These preliminary results have prompted ongoing evaluation of what specific aspects of CHA are valuable and which students benefit from computer-assisted learning in a multilingual and diverse cultural environment. Copyright © 2012 American Association of Anatomists.

  1. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  2. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    PubMed Central

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  3. [The history and development of computer assisted orthopaedic surgery].

    PubMed

    Jenny, J-Y

    2006-10-01

    Computer assisted orthopaedic surgery (CAOS) was developed to improve the accuracy of surgical procedures. It has improved dramatically over the last years, being transformed from an experimental, laboratory procedure into a routine procedure theoretically available to every orthopaedic surgeon. The first field of application of computer assistance was neurosurgery. After the application of computer guided spinal surgery, the navigation of total hip and knee joints became available. Currently, several applications for computer assisted surgery are available. At the beginning of navigation, a preoperative CT-scan or several fluoroscopic images were necessary. The imageless systems allow the surgeon to digitize patient anatomy at the beginning of surgery without any preoperative imaging. The future of CAOS remains unknown, but there is no doubt that its importance will grow in the next 10 years, and that this technology will probably modify the conventional practice of orthopaedic surgery.

  4. Automated virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Hunt, Gordon W.; Hemler, Paul F.; Vining, David J.

    1997-05-01

    Virtual colonscopy (VC) is a minimally invasive alternative to conventional fiberoptic endoscopy for colorectal cancer screening. The VC technique involves bowel cleansing, gas distension of the colon, spiral computed tomography (CT) scanning of a patient's abdomen and pelvis, and visual analysis of multiplanar 2D and 3D images created from the spiral CT data. Despite the ability of interactive computer graphics to assist a physician in visualizing 3D models of the colon, a correct diagnosis hinges upon a physician's ability to properly identify small and sometimes subtle polyps or masses within hundreds of multiplanar and 3D images. Human visual analysis is time-consuming, tedious, and often prone to error of interpretation.We have addressed the problem of visual analysis by creating a software system that automatically highlights potential lesions in the 2D and 3D images in order to expedite a physician's interpretation of the colon data.

  5. Image Analysis Algorithms for Immunohistochemical Assessment of Cell Death Events and Fibrosis in Tissue Sections

    PubMed Central

    Krajewska, Maryla; Smith, Layton H.; Rong, Juan; Huang, Xianshu; Hyer, Marc L.; Zeps, Nikolajs; Iacopetta, Barry; Linke, Steven P.; Olson, Allen H.; Reed, John C.; Krajewski, Stan

    2009-01-01

    Cell death is of broad physiological and pathological importance, making quantification of biochemical events associated with cell demise a high priority for experimental pathology. Fibrosis is a common consequence of tissue injury involving necrotic cell death. Using tissue specimens from experimental mouse models of traumatic brain injury, cardiac fibrosis, and cancer, as well as human tumor specimens assembled in tissue microarray (TMA) format, we undertook computer-assisted quantification of specific immunohistochemical and histological parameters that characterize processes associated with cell death. In this study, we demonstrated the utility of image analysis algorithms for color deconvolution, colocalization, and nuclear morphometry to characterize cell death events in tissue specimens: (a) subjected to immunostaining for detecting cleaved caspase-3, cleaved poly(ADP-ribose)-polymerase, cleaved lamin-A, phosphorylated histone H2AX, and Bcl-2; (b) analyzed by terminal deoxyribonucleotidyl transferase–mediated dUTP nick end labeling assay to detect DNA fragmentation; and (c) evaluated with Masson's trichrome staining. We developed novel algorithm-based scoring methods and validated them using TMAs as a high-throughput format. The proposed computer-assisted scoring methods for digital images by brightfield microscopy permit linear quantification of immunohistochemical and histochemical stainings. Examples are provided of digital image analysis performed in automated or semiautomated fashion for successful quantification of molecular events associated with cell death in tissue sections. (J Histochem Cytochem 57:649–663, 2009) PMID:19289554

  6. Computer-aided diagnosis workstation and teleradiology network system for chest diagnosis using the web medical image conference system with a new information security solution

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2010-03-01

    Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our teleradiology network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  7. Development and application of operational techniques for the inventory and monitoring of resources and uses for the Texas coastal zone. Volume 1: Text

    NASA Technical Reports Server (NTRS)

    Harwood, P. (Principal Investigator); Finley, R.; Mcculloch, S.; Malin, P. A.; Schell, J. A.

    1977-01-01

    The author has identified the following significant results. Image interpretation and computer-assisted techniques were developed to analyze LANDSAT scenes in support of resource inventory and monitoring requirements for the Texas coastal region. Land cover and land use maps, at a scale of 1:125,000 for the image interpretation product and 1:24,000 for the computer-assisted product, were generated covering four Texas coastal test sites. Classification schemes which parallel national systems were developed for each procedure, including 23 classes for image interpretation technique and 13 classes for the computer-assisted technique. Results indicate that LANDSAT-derived land cover and land use maps can be successfully applied to a variety of planning and management activities on the Texas coast. Computer-derived land/water maps can be used with tide gage data to assess shoreline boundaries for management purposes.

  8. Computer-assisted detection of epileptiform focuses on SPECT images

    NASA Astrophysics Data System (ADS)

    Grzegorczyk, Dawid; Dunin-Wąsowicz, Dorota; Mulawka, Jan J.

    2010-09-01

    Epilepsy is a common nervous system disease often related to consciousness disturbances and muscular spasm which affects about 1% of the human population. Despite major technological advances done in medicine in the last years there was no sufficient progress towards overcoming it. Application of advanced statistical methods and computer image analysis offers the hope for accurate detection and later removal of an epileptiform focuses which are the cause of some types of epilepsy. The aim of this work was to create a computer system that would help to find and diagnose disorders of blood circulation in the brain This may be helpful for the diagnosis of the epileptic seizures onset in the brain.

  9. Slicing for Biology.

    ERIC Educational Resources Information Center

    Ekstrom, James

    2001-01-01

    Advocates using computer imaging technology to assist students in doing projects in which determining density is important. Students can study quantitative comparisons of masses, lengths, and widths using computer software. Includes figures displaying computer images of shells, yeast cultures, and the Aral Sea. (SAH)

  10. A novel mechatronic tool for computer-assisted arthroscopy.

    PubMed

    Dario, P; Carrozza, M C; Marcacci, M; D'Attanasio, S; Magnami, B; Tonet, O; Megali, G

    2000-03-01

    This paper describes a novel mechatronic tool for arthroscopy, which is at the same time a smart tool for traditional arthroscopy and the main component of a system for computer-assisted arthroscopy. The mechatronic arthroscope has a cable-actuated servomotor-driven multi-joint mechanical structure, is equipped with a position sensor measuring the orientation of the tip and with a force sensor detecting possible contact with delicate tissues in the knee, and incorporates an embedded microcontroller for sensor signal processing, motor driving and interfacing with the surgeon and/or the system control unit. When used manually, the mechatronic arthroscope enhances the surgeon's capabilities by enabling him/her to easily control tip motion and to prevent undesired contacts. When the tool is integrated in a complete system for computer-assisted arthroscopy, the trajectory of the arthroscope is reconstructed in real time by an optical tracking system using infrared emitters located in the handle, providing advantages in terms of improved intervention accuracy. The computer-assisted arthroscopy system comprises an image processing module for segmentation and three-dimensional reconstruction of preoperative computer tomography or magnetic resonance images, a registration module for measuring the position of the knee joint, tracking the trajectory of the operating tools, and matching preoperative and intra-operative images, and a human-machine interface that displays the enhanced reality scenario and data from the mechatronic arthroscope in a friendly and intuitive manner. By integrating preoperative and intra-operative images and information provided by the mechatronic arthroscope, the system allows virtual navigation in the knee joint during the planning phase and computer guidance by augmented reality during the intervention. This paper describes in detail the characteristics of the mechatronic arthroscope and of the system for computer-assisted arthroscopy and discusses experimental results obtained with a preliminary version of the tool and of the system.

  11. Computer-assisted semen analysis and its utility for profiling boar semen samples.

    PubMed

    Didion, B A

    2008-11-01

    Achieving and maintaining a successful swine AI program depends on a number of factors, including accurate semen evaluation, typically sperm motility, morphology and concentration. Computer-Assisted Semen Analysis or CASA (i.e., image analysis with a phase-contrast microscope and computer measurements of motion parameters) objectively evaluates sperm motion characteristics, morphology and concentration. A total of 3077 semen collections were evaluated with CASA (on the day of collection), and a semen dose subset was used for single-sire AI of 6266 females over 6 months. Fertility data from these inseminations were fitted with models including farm/stud, line, boar, parity, mating week, semen age at mating and boar age at mating. The residuals from these models showed no correlation for any CASA semen unique motion parameter, which could be due to the level of sperm concentration, the number of inseminations per estrus, and the low number of females mated per boar. Future studies to expand CASA/fertility analysis need to address these constraints and may include analysis of extended boar semen after storage for 1 week.

  12. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  13. Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.

    PubMed

    Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting

    2014-01-01

    This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.

  14. Using computer assisted image analysis to determine the optimal Ki67 threshold for predicting outcome of invasive breast cancer

    PubMed Central

    Tay, Timothy Kwang Yong; Thike, Aye Aye; Pathmanathan, Nirmala; Jara-Lazaro, Ana Richelia; Iqbal, Jabed; Sng, Adeline Shi Hui; Ye, Heng Seow; Lim, Jeffrey Chun Tatt; Koh, Valerie Cui Yun; Tan, Jane Sie Yong; Yeong, Joe Poh Sheng; Chow, Zi Long; Li, Hui Hua; Cheng, Chee Leong; Tan, Puay Hoon

    2018-01-01

    Background Ki67 positivity in invasive breast cancers has an inverse correlation with survival outcomes and serves as an immunohistochemical surrogate for molecular subtyping of breast cancer, particularly ER positive breast cancer. The optimal threshold of Ki67 in both settings, however, remains elusive. We use computer assisted image analysis (CAIA) to determine the optimal threshold for Ki67 in predicting survival outcomes and differentiating luminal B from luminal A breast cancers. Methods Quantitative scoring of Ki67 on tissue microarray (TMA) sections of 440 invasive breast cancers was performed using Aperio ePathology ImmunoHistochemistry Nuclear Image Analysis algorithm, with TMA slides digitally scanned via Aperio ScanScope XT System. Results On multivariate analysis, tumours with Ki67 ≥14% had an increased likelihood of recurrence (HR 1.941, p=0.021) and shorter overall survival (HR 2.201, p=0.016). Similar findings were observed in the subset of 343 ER positive breast cancers (HR 2.409, p=0.012 and HR 2.787, p=0.012 respectively). The value of Ki67 associated with ER+HER2-PR<20% tumours (Luminal B subtype) was found to be <17%. Conclusion Using CAIA, we found optimal thresholds for Ki67 that predict a poorer prognosis and an association with the Luminal B subtype of breast cancer. Further investigation and validation of these thresholds are recommended. PMID:29545924

  15. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    PubMed Central

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-01-01

    The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137

  16. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-12-15

    The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less

  17. The microcomputer in the dental office: a new diagnostic aid.

    PubMed

    van der Stelt, P F

    1985-06-01

    The first computer applications in the dental office were based upon standard accountancy procedures. Recently, more and more computer applications have become available to meet the specific requirements of dental practice. This implies not only business procedures, but also facilities to store patient records in the system and retrieve them easily. Another development concerns the automatic calculation of diagnostic data such as those provided in cephalometric analysis. Furthermore, growth and surgical results in the craniofacial area can be predicted by computerized extrapolation. Computers have been useful in obtaining the patient's anamnestic data objectively and for the making of decisions based on such data. Computer-aided instruction systems have been developed for undergraduate students to bridge the gap between textbook and patient interaction without the risks inherent in the latter. Radiology will undergo substantial changes as a result of the application of electronic imaging devices instead of the conventional radiographic films. Computer-assisted electronic imaging will enable image processing, image enhancement, pattern recognition and data transmission for consultation and storage purposes. Image processing techniques will increase image quality whilst still allowing low-dose systems. Standardization of software and system configuration and the development of 'user friendly' programs is the major concern for the near future.

  18. Computer Vision Assisted Virtual Reality Calibration

    NASA Technical Reports Server (NTRS)

    Kim, W.

    1999-01-01

    A computer vision assisted semi-automatic virtual reality (VR) calibration technology has been developed that can accurately match a virtual environment of graphically simulated three-dimensional (3-D) models to the video images of the real task environment.

  19. Interactive, computer-assisted tracking of speckle trajectories in fluorescence microscopy: application to actin polymerization and membrane fusion.

    PubMed

    Smith, Matthew B; Karatekin, Erdem; Gohlke, Andrea; Mizuno, Hiroaki; Watanabe, Naoki; Vavylonis, Dimitrios

    2011-10-05

    Analysis of particle trajectories in images obtained by fluorescence microscopy reveals biophysical properties such as diffusion coefficient or rates of association and dissociation. Particle tracking and lifetime measurement is often limited by noise, large mobilities, image inhomogeneities, and path crossings. We present Speckle TrackerJ, a tool that addresses some of these challenges using computer-assisted techniques for finding positions and tracking particles in different situations. A dynamic user interface assists in the creation, editing, and refining of particle tracks. The following are results from application of this program: 1), Tracking single molecule diffusion in simulated images. The shape of the diffusing marker on the image changes from speckle to cloud, depending on the relationship of the diffusion coefficient to the camera exposure time. We use these images to illustrate the range of diffusion coefficients that can be measured. 2), We used the program to measure the diffusion coefficient of capping proteins in the lamellipodium. We found values ∼0.5 μm(2)/s, suggesting capping protein association with protein complexes or the membrane. 3), We demonstrate efficient measuring of appearance and disappearance of EGFP-actin speckles within the lamellipodium of motile cells that indicate actin monomer incorporation into the actin filament network. 4), We marked appearance and disappearance events of fluorescently labeled vesicles to supported lipid bilayers and tracked single lipids from the fused vesicle on the bilayer. This is the first time, to our knowledge, that vesicle fusion has been detected with single molecule sensitivity and the program allowed us to perform a quantitative analysis. 5), By discriminating between undocking and fusion events, dwell times for vesicle fusion after vesicle docking to membranes can be measured. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Development of a Reference Image Collection Library for Histopathology Image Processing, Analysis and Decision Support Systems Research.

    PubMed

    Kostopoulos, Spiros; Ravazoula, Panagiota; Asvestas, Pantelis; Kalatzis, Ioannis; Xenogiannopoulos, George; Cavouras, Dionisis; Glotsos, Dimitris

    2017-06-01

    Histopathology image processing, analysis and computer-aided diagnosis have been shown as effective assisting tools towards reliable and intra-/inter-observer invariant decisions in traditional pathology. Especially for cancer patients, decisions need to be as accurate as possible in order to increase the probability of optimal treatment planning. In this study, we propose a new image collection library (HICL-Histology Image Collection Library) comprising 3831 histological images of three different diseases, for fostering research in histopathology image processing, analysis and computer-aided diagnosis. Raw data comprised 93, 116 and 55 cases of brain, breast and laryngeal cancer respectively collected from the archives of the University Hospital of Patras, Greece. The 3831 images were generated from the most representative regions of the pathology, specified by an experienced histopathologist. The HICL Image Collection is free for access under an academic license at http://medisp.bme.teiath.gr/hicl/ . Potential exploitations of the proposed library may span over a board spectrum, such as in image processing to improve visualization, in segmentation for nuclei detection, in decision support systems for second opinion consultations, in statistical analysis for investigation of potential correlations between clinical annotations and imaging findings and, generally, in fostering research on histopathology image processing and analysis. To the best of our knowledge, the HICL constitutes the first attempt towards creation of a reference image collection library in the field of traditional histopathology, publicly and freely available to the scientific community.

  1. Pathologists' Computer-Assisted Diagnosis: A Mock-up of a Prototype Information System to Facilitate Automation of Pathology Sign-out.

    PubMed

    Farahani, Navid; Liu, Zheng; Jutt, Dylan; Fine, Jeffrey L

    2017-10-01

    - Pathologists' computer-assisted diagnosis (pCAD) is a proposed framework for alleviating challenges through the automation of their routine sign-out work. Currently, hypothetical pCAD is based on a triad of advanced image analysis, deep integration with heterogeneous information systems, and a concrete understanding of traditional pathology workflow. Prototyping is an established method for designing complex new computer systems such as pCAD. - To describe, in detail, a prototype of pCAD for the sign-out of a breast cancer specimen. - Deidentified glass slides and data from breast cancer specimens were used. Slides were digitized into whole-slide images with an Aperio ScanScope XT, and screen captures were created by using vendor-provided software. The advanced workflow prototype was constructed by using PowerPoint software. - We modeled an interactive, computer-assisted workflow: pCAD previews whole-slide images in the context of integrated, disparate data and predefined diagnostic tasks and subtasks. Relevant regions of interest (ROIs) would be automatically identified and triaged by the computer. A pathologist's sign-out work would consist of an interactive review of important ROIs, driven by required diagnostic tasks. The interactive session would generate a pathology report automatically. - Using animations and real ROIs, the pCAD prototype demonstrates the hypothetical sign-out in a stepwise fashion, illustrating various interactions and explaining how steps can be automated. The file is publicly available and should be widely compatible. This mock-up is intended to spur discussion and to help usher in the next era of digitization for pathologists by providing desperately needed and long-awaited automation.

  2. RecceMan: an interactive recognition assistance for image-based reconnaissance: synergistic effects of human perception and computational methods for object recognition, identification, and infrastructure analysis

    NASA Astrophysics Data System (ADS)

    El Bekri, Nadia; Angele, Susanne; Ruckhäberle, Martin; Peinsipp-Byma, Elisabeth; Haelke, Bruno

    2015-10-01

    This paper introduces an interactive recognition assistance system for imaging reconnaissance. This system supports aerial image analysts on missions during two main tasks: Object recognition and infrastructure analysis. Object recognition concentrates on the classification of one single object. Infrastructure analysis deals with the description of the components of an infrastructure and the recognition of the infrastructure type (e.g. military airfield). Based on satellite or aerial images, aerial image analysts are able to extract single object features and thereby recognize different object types. It is one of the most challenging tasks in the imaging reconnaissance. Currently, there are no high potential ATR (automatic target recognition) applications available, as consequence the human observer cannot be replaced entirely. State-of-the-art ATR applications cannot assume in equal measure human perception and interpretation. Why is this still such a critical issue? First, cluttered and noisy images make it difficult to automatically extract, classify and identify object types. Second, due to the changed warfare and the rise of asymmetric threats it is nearly impossible to create an underlying data set containing all features, objects or infrastructure types. Many other reasons like environmental parameters or aspect angles compound the application of ATR supplementary. Due to the lack of suitable ATR procedures, the human factor is still important and so far irreplaceable. In order to use the potential benefits of the human perception and computational methods in a synergistic way, both are unified in an interactive assistance system. RecceMan® (Reconnaissance Manual) offers two different modes for aerial image analysts on missions: the object recognition mode and the infrastructure analysis mode. The aim of the object recognition mode is to recognize a certain object type based on the object features that originated from the image signatures. The infrastructure analysis mode pursues the goal to analyze the function of the infrastructure. The image analyst extracts visually certain target object signatures, assigns them to corresponding object features and is finally able to recognize the object type. The system offers him the possibility to assign the image signatures to features given by sample images. The underlying data set contains a wide range of objects features and object types for different domains like ships or land vehicles. Each domain has its own feature tree developed by aerial image analyst experts. By selecting the corresponding features, the possible solution set of objects is automatically reduced and matches only the objects that contain the selected features. Moreover, we give an outlook of current research in the field of ground target analysis in which we deal with partly automated methods to extract image signatures and assign them to the corresponding features. This research includes methods for automatically determining the orientation of an object and geometric features like width and length of the object. This step enables to reduce automatically the possible object types offered to the image analyst by the interactive recognition assistance system.

  3. PitScan: Computer-Assisted Feature Detection

    NASA Astrophysics Data System (ADS)

    Wagner, R. V.; Robinson, M. S.

    2018-04-01

    We developed PitScan to assist in searching the very large LROC image dataset for pits — unusual <200m wide vertical-walled holes in the Moon's surface. PitScan reduces analysts' workload by pre-filtering images to identify possible pits.

  4. The recognition of potato varieties using of neural image analysis method

    NASA Astrophysics Data System (ADS)

    Przybył, K.; Górna, K.; Wojcieszak, D.; Czekała, W.; Ludwiczak, A.; Przybylak, A.; Boniecki, P.; Koszela, K.; Zaborowicz, M.; Janczak, D.; Lewicki, A.

    2015-07-01

    The aim of this paper was to extract the representative features and generate an appropriate neural model for classification of varieties of edible potato. Potatoes of variety the Vineta and the Denar were the empirical object of this thesis. The main concept of the project was to develop and prepare an image database using the computer image analysis software. The choice of appropriate neural model the one which will have the greatest abilities to identify the selected variety. The aim of this project is ultimately to conduct assistance and accelerate work of the expert, who classifies and keeps different varieties of potatoes in heaps.

  5. Computer-assisted image processing to detect spores from the fungus Pandora neoaphidis.

    PubMed

    Korsnes, Reinert; Westrum, Karin; Fløistad, Erling; Klingen, Ingeborg

    2016-01-01

    This contribution demonstrates an example of experimental automatic image analysis to detect spores prepared on microscope slides derived from trapping. The application is to monitor aerial spore counts of the entomopathogenic fungus Pandora neoaphidis which may serve as a biological control agent for aphids. Automatic detection of such spores can therefore play a role in plant protection. The present approach for such detection is a modification of traditional manual microscopy of prepared slides, where autonomous image recording precedes computerised image analysis. The purpose of the present image analysis is to support human visual inspection of imagery data - not to replace it. The workflow has three components:•Preparation of slides for microscopy.•Image recording.•Computerised image processing where the initial part is, as usual, segmentation depending on the actual data product. Then comes identification of blobs, calculation of principal axes of blobs, symmetry operations and projection on a three parameter egg shape space.

  6. Medical imaging and registration in computer assisted surgery.

    PubMed

    Simon, D A; Lavallée, S

    1998-09-01

    Imaging, sensing, and computing technologies that are being introduced to aid in the planning and execution of surgical procedures are providing orthopaedic surgeons with a powerful new set of tools for improving clinical accuracy, reliability, and patient outcomes while reducing costs and operating times. Current computer assisted surgery systems typically include a measurement process for collecting patient specific medical data, a decision making process for generating a surgical plan, a registration process for aligning the surgical plan to the patient, and an action process for accurately achieving the goals specified in the plan. Some of the key concepts in computer assisted surgery applied to orthopaedics with a focus on the basic framework and underlying technologies is outlined. In addition, technical challenges and future trends in the field are discussed.

  7. The Use of Images in Intelligent Advisor Systems.

    ERIC Educational Resources Information Center

    Boulet, Marie-Michele

    This paper describes the intelligent advisor system, named CODAMA, used in teaching a university-level systems analysis and design course. The paper discusses: (1) the use of CODAMA to assist students to transfer theoretical knowledge to the practical; (2) details of how CODAMA is applied in conjunction with a computer-aided software engineering…

  8. Semi-Automated Identification of Rocks in Images

    NASA Technical Reports Server (NTRS)

    Bornstein, Benjamin; Castano, Andres; Anderson, Robert

    2006-01-01

    Rock Identification Toolkit Suite is a computer program that assists users in identifying and characterizing rocks shown in images returned by the Mars Explorer Rover mission. Included in the program are components for automated finding of rocks, interactive adjustments of outlines of rocks, active contouring of rocks, and automated analysis of shapes in two dimensions. The program assists users in evaluating the surface properties of rocks and soil and reports basic properties of rocks. The program requires either the Mac OS X operating system running on a G4 (or more capable) processor or a Linux operating system running on a Pentium (or more capable) processor, plus at least 128MB of random-access memory.

  9. Quantitative fibrosis parameters highly predict esophageal-gastro varices in primary biliary cirrhosis.

    PubMed

    Wu, Q-M; Zhao, X-Y; You, H

    2016-01-01

    Esophageal-gastro Varices (EGV) may develop in any histological stages of primary biliary cirrhosis (PBC). We aim to establish and validate quantitative fibrosis (qFibrosis) parameters in portal, septal and fibrillar areas as ideal predictors of EGV in PBC patients. PBC patients with liver biopsy, esophagogastroscopy and Second Harmonic Generation (SHG)/Two-photon Excited Fluorescence (TPEF) microscopy images were retrospectively enrolled in this study. qFibrosis parameters in portal, septal and fibrillar areas were acquired by computer-assisted SHG/TPEF imaging system. Independent predictor was identified using multivariate logistic regression analysis. PBC patients with liver biopsy, esophagogastroscopy and Second Harmonic Generation (SHG)/Two-photon Excited Fluorescence (TPEF) microscopy images were retrospectively enrolled in this study. qFibrosis parameters in portal, septal and fibrillar areas were acquired by computer-assisted SHG/TPEF imaging system. Independent predictor was identified using multivariate logistic regression analysis. Among the forty-nine PBC patients with qFibrosis images, twenty-nine PBC patients with both esophagogastroscopy data and qFibrosis data were selected out for EGV prognosis analysis and 44.8% (13/29) of them had EGV. The qFibrosis parameters of collagen percentage and number of crosslink in fibrillar area, short/long/thin strings number and length/width of the strings in septa area were associated with EGV (p < 0.05). Multivariate logistic analysis showed that the collagen percentage in fibrillar area ≥ 3.6% was an independent factor to predict EGV (odds ratio 6.9; 95% confidence interval 1.6-27.4). The area under receiver operating characteristic (ROC), diagnostic sensitivity and specificity was 0.9, 100% and 75% respectively. Collagen percentage in Collagen percentage in the fibrillar area as an independent predictor can highly predict EGV in PBC patients.

  10. Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system.

    PubMed

    Kuhl, Mitchell; Beimel, Claudia

    2016-10-01

    The goal of this study was to evaluate the ability of a novel computer assisted surgery system to guide ideal placement of a lag screw during cephalomedullary nailing and then accurately measure the tip-apex distance (TAD) measurement intraoperatively. Retrospective case review. Level II trauma hospital. The initial 98 consecutive clinical cases treated with a cephalomedullary nail in conjunction with a novel computer assisted surgery system were retrospectively reviewed. A novel computer assisted surgery system was utilized to enhance lag screw placement during cephalomedullary nailing procedures. The computer assisted surgery system calculates the TAD intraoperatively after final lag screw placement. The ideal TAD was considered to be within a range of 5mm-20mm. The ability of the computer assisted surgery system (CASS) to assist in placement of a lag screw within the ideal TAD was evaluated. Intraoperative TAD measurements provided by the computer assisted surgery system were then compared to standard postoperative TAD measurements on PACS (picture archiving and communication system) images to determine whether these measurements are equivalent. 79 cases (80.6%) were available with complete information for a retrospective review. All cases had CASS TAD and PACS TAD measurements >5mm and<20mm. In addition, no significant difference could be detected between the intraoperative CASS TAD and the postoperative PACS TAD (p=0.374, Wilcoxon Test; p=0.174, paired T-Test). A cut-out rate of 0% was observed in all patients who were treated with CASS in this case series (95% CI: 0 - 3.01%). The novel computer assisted surgery system tested here is an effective and reliable adjunct that can be utilized for optimal lag screw placement in cephalomedullary nailing procedures. The computer assisted surgery system provides an accurate intraoperative TAD measurement that is equivalent to the standard postoperative measurement utilizing PACS images. Therapeutic Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Quantitative immunohistochemistry of factor VIII-related antigen in breast carcinoma: a comparison of computer-assisted image analysis with established counting methods.

    PubMed

    Kohlberger, P D; Obermair, A; Sliutz, G; Heinzl, H; Koelbl, H; Breitenecker, G; Gitsch, G; Kainz, C

    1996-06-01

    Microvessel density in the area of the most intense neovascularization in invasive breast carcinoma is reported to be an independent prognostic factor. The established method of enumeration of microvessel density is to count the vessels using an ocular raster (counted microvessel density [CMVD]). The vessels were detected by staining endothelial cells using Factor VIII-related antigen. The aim of the study was to compare the CMVD results with the percentage of factor VIII-related antigen-stained area using computer-assisted image analysis. A true color red-green-blue (RGB) image analyzer based on a morphologically reduced instruction set computer processor was used to evaluate the area of stained endothelial cells. Sixty invasive breast carcinomas were included in the analysis. There was no significant correlation between the CMVD and the percentage of factor VIII-related antigen-stained area (Spearman correlation coefficient = 0.24, confidence interval = 0.02-0.46). Although high CMVD was significantly correlated with poorer recurrence free survival (P = .024), percentage of factor VIII-related antigen-stained area showed no prognostic value. Counted microvessel density and percentage of factor VIII-related antigen-stained area showed a highly significant correlation with vessel invasion (P = .0001 and P = .02, respectively). There was no correlation between CMVD and percentage of factor VIII-related antigen-stained area with other prognostic factors. In contrast to the CMVD within malignant tissue, the percentage of factor VIII-related antigen-stained area is not suitable as an indicator of prognosis in breast cancer patients.

  12. VRML Industry: Microcosms in the Making.

    ERIC Educational Resources Information Center

    Brown, Eric

    1998-01-01

    Discusses VRML (Virtual Reality Modeling Language) technology and some of its possible applications, including creating three-dimensional images on the Web, advertising, and data visualization in computer-assisted design and computer-assisted manufacturing (CAD/CAM). Future improvements are discussed, including streaming, database support, and…

  13. Image-based computer-assisted diagnosis system for benign paroxysmal positional vertigo

    NASA Astrophysics Data System (ADS)

    Kohigashi, Satoru; Nakamae, Koji; Fujioka, Hiromu

    2005-04-01

    We develop the image based computer assisted diagnosis system for benign paroxysmal positional vertigo (BPPV) that consists of the balance control system simulator, the 3D eye movement simulator, and the extraction method of nystagmus response directly from an eye movement image sequence. In the system, the causes and conditions of BPPV are estimated by searching the database for record matching with the nystagmus response for the observed eye image sequence of the patient with BPPV. The database includes the nystagmus responses for simulated eye movement sequences. The eye movement velocity is obtained by using the balance control system simulator that allows us to simulate BPPV under various conditions such as canalithiasis, cupulolithiasis, number of otoconia, otoconium size, and so on. Then the eye movement image sequence is displayed on the CRT by the 3D eye movement simulator. The nystagmus responses are extracted from the image sequence by the proposed method and are stored in the database. In order to enhance the diagnosis accuracy, the nystagmus response for a newly simulated sequence is matched with that for the observed sequence. From the matched simulation conditions, the causes and conditions of BPPV are estimated. We apply our image based computer assisted diagnosis system to two real eye movement image sequences for patients with BPPV to show its validity.

  14. Utility of fluorescence microscopy in embryonic/fetal topographical analysis.

    PubMed

    Zucker, R M; Elstein, K H; Shuey, D L; Ebron-McCoy, M; Rogers, J M

    1995-06-01

    For topographical analysis of developing embryos, investigators typically rely on scanning electron microscopy (SEM) to provide the surface detail not attainable with light microscopy. SEM is an expensive and time-consuming technique, however, and the preparation procedure may alter morphology and leave the specimen friable. We report that by using a high-resolution compound epifluorescence microscope with inexpensive low-power objectives and the fluorochrome acridine orange, we were able to obtain surface images of fixed or fresh whole rat embryos and fetal palates of considerably greater topographical detail than those obtained using routine light microscopy. Indeed the resulting high-resolution images afford not only superior qualitative documentation of morphological observations, but the capability for detailed morphometry via digitization and computer-assisted image analysis.

  15. CAD system for automatic analysis of CT perfusion maps

    NASA Astrophysics Data System (ADS)

    Hachaj, T.; Ogiela, M. R.

    2011-03-01

    In this article, authors present novel algorithms developed for the computer-assisted diagnosis (CAD) system for analysis of dynamic brain perfusion, computer tomography (CT) maps, cerebral blood flow (CBF), and cerebral blood volume (CBV). Those methods perform both quantitative analysis [detection and measurement and description with brain anatomy atlas (AA) of potential asymmetries/lesions] and qualitative analysis (semantic interpretation of visualized symptoms). The semantic interpretation (decision about type of lesion: ischemic/hemorrhagic, is the brain tissue at risk of infraction or not) of visualized symptoms is done by, so-called, cognitive inference processes allowing for reasoning on character of pathological regions based on specialist image knowledge. The whole system is implemented in.NET platform (C# programming language) and can be used on any standard PC computer with.NET framework installed.

  16. Asynchronous data acquisition and on-the-fly analysis of dose fractionated cryoEM images by UCSFImage

    PubMed Central

    Li, Xueming; Zheng, Shawn; Agard, David A.; Cheng, Yifan

    2015-01-01

    Newly developed direct electron detection cameras have a high image output frame rate that enables recording dose fractionated image stacks of frozen hydrated biological samples by electron cryomicroscopy (cryoEM). Such novel image acquisition schemes provide opportunities to analyze cryoEM data in ways that were previously impossible. The file size of a dose fractionated image stack is 20 ~ 60 times larger than that of a single image. Thus, efficient data acquisition and on-the-fly analysis of a large number of dose-fractionated image stacks become a serious challenge to any cryoEM data acquisition system. We have developed a computer-assisted system, named UCSFImage4, for semi-automated cryo-EM image acquisition that implements an asynchronous data acquisition scheme. This facilitates efficient acquisition, on-the-fly motion correction, and CTF analysis of dose fractionated image stacks with a total time of ~60 seconds/exposure. Here we report the technical details and configuration of this system. PMID:26370395

  17. Histology image analysis for carcinoma detection and grading

    PubMed Central

    He, Lei; Long, L. Rodney; Antani, Sameer; Thoma, George R.

    2012-01-01

    This paper presents an overview of the image analysis techniques in the domain of histopathology, specifically, for the objective of automated carcinoma detection and classification. As in other biomedical imaging areas such as radiology, many computer assisted diagnosis (CAD) systems have been implemented to aid histopathologists and clinicians in cancer diagnosis and research, which have been attempted to significantly reduce the labor and subjectivity of traditional manual intervention with histology images. The task of automated histology image analysis is usually not simple due to the unique characteristics of histology imaging, including the variability in image preparation techniques, clinical interpretation protocols, and the complex structures and very large size of the images themselves. In this paper we discuss those characteristics, provide relevant background information about slide preparation and interpretation, and review the application of digital image processing techniques to the field of histology image analysis. In particular, emphasis is given to state-of-the-art image segmentation methods for feature extraction and disease classification. Four major carcinomas of cervix, prostate, breast, and lung are selected to illustrate the functions and capabilities of existing CAD systems. PMID:22436890

  18. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    PubMed

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  19. Computer assisted analysis of auroral images obtained from high altitude polar satellites

    NASA Technical Reports Server (NTRS)

    Samadani, Ramin; Flynn, Michael

    1993-01-01

    Automatic techniques that allow the extraction of physically significant parameters from auroral images were developed. This allows the processing of a much larger number of images than is currently possible with manual techniques. Our techniques were applied to diverse auroral image datasets. These results were made available to geophysicists at NASA and at universities in the form of a software system that performs the analysis. After some feedback from users, an upgraded system was transferred to NASA and to two universities. The feasibility of user-trained search and retrieval of large amounts of data using our automatically derived parameter indices was demonstrated. Techniques based on classification and regression trees (CART) were developed and applied to broaden the types of images to which the automated search and retrieval may be applied. Our techniques were tested with DE-1 auroral images.

  20. [Computer-assisted image processing for quantifying histopathologic variables in the healing of colonic anastomosis in dogs].

    PubMed

    Novelli, M D; Barreto, E; Matos, D; Saad, S S; Borra, R C

    1997-01-01

    The authors present the experimental results of the computerized quantifying of tissular structures involved in the reparative process of colonic anastomosis performed by manual suture and biofragmentable ring. The quantified variables in this study were: oedema fluid, myofiber tissue, blood vessel and cellular nuclei. An image processing software developed at Laboratório de Informática Dedicado à Odontologia (LIDO) was utilized to quantifying the pathognomonic alterations in the inflammatory process in colonic anastomosis performed in 14 dogs. The results were compared to those obtained through traditional way diagnosis by two pathologists in view of counterproof measures. The criteria for these diagnoses were defined in levels represented by absent, light, moderate and intensive which were compared to analysis performed by the computer. There was significant statistical difference between two techniques: the biofragmentable ring technique exhibited low oedema fluid, organized myofiber tissue and higher number of alongated cellular nuclei in relation to manual suture technique. The analysis of histometric variables through computational image processing was considered efficient and powerful to quantify the main tissular inflammatory and reparative changing.

  1. Image analysis and machine learning in digital pathology: Challenges and opportunities.

    PubMed

    Madabhushi, Anant; Lee, George

    2016-10-01

    With the rise in whole slide scanner technology, large numbers of tissue slides are being scanned and represented and archived digitally. While digital pathology has substantial implications for telepathology, second opinions, and education there are also huge research opportunities in image computing with this new source of "big data". It is well known that there is fundamental prognostic data embedded in pathology images. The ability to mine "sub-visual" image features from digital pathology slide images, features that may not be visually discernible by a pathologist, offers the opportunity for better quantitative modeling of disease appearance and hence possibly improved prediction of disease aggressiveness and patient outcome. However the compelling opportunities in precision medicine offered by big digital pathology data come with their own set of computational challenges. Image analysis and computer assisted detection and diagnosis tools previously developed in the context of radiographic images are woefully inadequate to deal with the data density in high resolution digitized whole slide images. Additionally there has been recent substantial interest in combining and fusing radiologic imaging and proteomics and genomics based measurements with features extracted from digital pathology images for better prognostic prediction of disease aggressiveness and patient outcome. Again there is a paucity of powerful tools for combining disease specific features that manifest across multiple different length scales. The purpose of this review is to discuss developments in computational image analysis tools for predictive modeling of digital pathology images from a detection, segmentation, feature extraction, and tissue classification perspective. We discuss the emergence of new handcrafted feature approaches for improved predictive modeling of tissue appearance and also review the emergence of deep learning schemes for both object detection and tissue classification. We also briefly review some of the state of the art in fusion of radiology and pathology images and also combining digital pathology derived image measurements with molecular "omics" features for better predictive modeling. The review ends with a brief discussion of some of the technical and computational challenges to be overcome and reflects on future opportunities for the quantitation of histopathology. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Computer Assisted Virtual Environment - CAVE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, Phillip; Podgorney, Robert; Weingartner,

    Research at the Center for Advanced Energy Studies is taking on another dimension with a 3-D device known as a Computer Assisted Virtual Environment. The CAVE uses projection to display high-end computer graphics on three walls and the floor. By wearing 3-D glasses to create depth perception and holding a wand to move and rotate images, users can delve into data.

  3. Algerian EFL University Teachers' Attitudes towards Computer Assisted Language Learning: The Case of Djilali Liabes University

    ERIC Educational Resources Information Center

    Bouchefra, Miloud; Baghoussi, Meriem

    2017-01-01

    Computer Assisted Language Learning (CALL) is still groping its way into Algerian English as a Foreign Language (EFL) classroom, where Information Communications Technologies (ICTs) are defined in terms of occasional use of computers and data projectors for material presentation in the classroom. Though major issues in the image of the lack of…

  4. Computer Assisted Virtual Environment - CAVE

    ScienceCinema

    Erickson, Phillip; Podgorney, Robert; Weingartner,

    2018-05-30

    Research at the Center for Advanced Energy Studies is taking on another dimension with a 3-D device known as a Computer Assisted Virtual Environment. The CAVE uses projection to display high-end computer graphics on three walls and the floor. By wearing 3-D glasses to create depth perception and holding a wand to move and rotate images, users can delve into data.

  5. Phantom feet on digital radionuclide images and other scary computer tales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freitas, J.E.; Dworkin, H.J.; Dees, S.M.

    1989-09-01

    Malfunction of a computer-assisted digital gamma camera is reported. Despite what appeared to be adequate acceptance testing, an error in the system gave rise to switching of images and identification text. A suggestion is made for using a hot marker, which would avoid the potential error of misinterpretation of patient images.

  6. From macro-scale to micro-scale computational anatomy: a perspective on the next 20 years.

    PubMed

    Mori, Kensaku

    2016-10-01

    This paper gives our perspective on the next two decades of computational anatomy, which has made great strides in the recognition and understanding of human anatomy from conventional clinical images. The results from this field are now used in a variety of medical applications, including quantitative analysis of organ shapes, interventional assistance, surgical navigation, and population analysis. Several anatomical models have also been used in computational anatomy, and these mainly target millimeter-scale shapes. For example, liver-shape models are almost completely modeled at the millimeter scale, and shape variations are described at such scales. Most clinical 3D scanning devices have had just under 1 or 0.5 mm per voxel resolution for over 25 years, and this resolution has not changed drastically in that time. Although Z-axis (head-to-tail direction) resolution has been drastically improved by the introduction of multi-detector CT scanning devices, in-plane resolutions have not changed very much either. When we look at human anatomy, we can see different anatomical structures at different scales. For example, pulmonary blood vessels and lung lobes can be observed in millimeter-scale images. If we take 10-µm-scale images of a lung specimen, the alveoli and bronchiole regions can be located in them. Most work in millimeter-scale computational anatomy has been done by the medical-image analysis community. In the next two decades, we encourage our community to focus on micro-scale computational anatomy. In this perspective paper, we briefly review the achievements of computational anatomy and its impacts on clinical applications; furthermore, we show several possibilities from the viewpoint of microscopic computational anatomy by discussing experimental results from our recent research activities. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Computer-assisted cervical cancer screening using neural networks.

    PubMed

    Mango, L J

    1994-03-15

    A practical and effective system for the computer-assisted screening of conventionally prepared cervical smears is presented and described. Recent developments in neural network technology have made computerized analysis of the complex cellular scenes found on Pap smears possible. The PAPNET Cytological Screening System uses neural networks to automatically analyze conventional smears by locating and recognizing potentially abnormal cells. It then displays images of these objects for review and final diagnosis by qualified cytologists. The results of the studies presented indicate that the PAPNET system could be a useful tool for both the screening and rescreening of cervical smears. In addition, the system has been shown to be sensitive to some types of abnormalities which have gone undetected during manual screening.

  8. Surface Modeling, Solid Modeling and Finite Element Modeling. Analysis Capabilities of Computer-Assisted Design and Manufacturing Systems.

    ERIC Educational Resources Information Center

    Nee, John G.; Kare, Audhut P.

    1987-01-01

    Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)

  9. Automatic small bowel tumor diagnosis by using multi-scale wavelet-based analysis in wireless capsule endoscopy images.

    PubMed

    Barbosa, Daniel C; Roupar, Dalila B; Ramos, Jaime C; Tavares, Adriano C; Lima, Carlos S

    2012-01-11

    Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.

  10. A Knowledge-Based System for the Computer Assisted Diagnosis of Endoscopic Images

    NASA Astrophysics Data System (ADS)

    Kage, Andreas; Münzenmayer, Christian; Wittenberg, Thomas

    Due to the actual demographic development the use of Computer-Assisted Diagnosis (CAD) systems becomes a more important part of clinical workflows and clinical decision making. Because changes on the mucosa of the esophagus can indicate the first stage of cancerous developments, there is a large interest to detect and correctly diagnose any such lesion. We present a knowledge-based system which is able to support a physician with the interpretation and diagnosis of endoscopic images of the esophagus. Our system is designed to support the physician directly during the examination of the patient, thus prodving diagnostic assistence at the point of care (POC). Based on an interactively marked region in an endoscopic image of interest, the system provides a diagnostic suggestion, based on an annotated reference image database. Furthermore, using relevant feedback mechanisms, the results can be enhanced interactively.

  11. Computer-assisted surgical planning and automation of laser delivery systems

    NASA Astrophysics Data System (ADS)

    Zamorano, Lucia J.; Dujovny, Manuel; Dong, Ada; Kadi, A. Majeed

    1991-05-01

    This paper describes a 'real time' surgical treatment planning interactive workstation, utilizing multimodality imaging (computer tomography, magnetic resonance imaging, digital angiography) that has been developed to provide the neurosurgeon with two-dimensional multiplanar and three-dimensional 'display' of a patient's lesion.

  12. X-Ray Radiography of Gas Turbine Ceramics.

    DTIC Science & Technology

    1979-10-20

    Microfocus X-ray equipment. 1a4ihe definition of equipment concepts for a computer assisted tomography ( CAT ) system; and 4ffthe development of a CAT ...were obtained from these test coupons using Microfocus X-ray and image en- hancement techniques. A Computer Assisted Tomography ( CAT ) design concept...monitor. Computer reconstruction algorithms were investigated with respect to CAT and a preferred approach was determined. An appropriate CAT algorithm

  13. Quantifying fish swimming behavior in response to acute exposure of aqueous copper using computer assisted video and digital image analysis

    USGS Publications Warehouse

    Calfee, Robin D.; Puglis, Holly J.; Little, Edward E.; Brumbaugh, William G.; Mebane, Christopher A.

    2016-01-01

    Behavioral responses of aquatic organisms to environmental contaminants can be precursors of other effects such as survival, growth, or reproduction. However, these responses may be subtle, and measurement can be challenging. Using juvenile white sturgeon (Acipenser transmontanus) with copper exposures, this paper illustrates techniques used for quantifying behavioral responses using computer assisted video and digital image analysis. In previous studies severe impairments in swimming behavior were observed among early life stage white sturgeon during acute and chronic exposures to copper. Sturgeon behavior was rapidly impaired and to the extent that survival in the field would be jeopardized, as fish would be swept downstream, or readily captured by predators. The objectives of this investigation were to illustrate protocols to quantify swimming activity during a series of acute copper exposures to determine time to effect during early lifestage development, and to understand the significance of these responses relative to survival of these vulnerable early lifestage fish. With mortality being on a time continuum, determining when copper first affects swimming ability helps us to understand the implications for population level effects. The techniques used are readily adaptable to experimental designs with other organisms and stressors.

  14. Quantifying Fish Swimming Behavior in Response to Acute Exposure of Aqueous Copper Using Computer Assisted Video and Digital Image Analysis

    PubMed Central

    Calfee, Robin D.; Puglis, Holly J.; Little, Edward E.; Brumbaugh, William G.; Mebane, Christopher A.

    2016-01-01

    Behavioral responses of aquatic organisms to environmental contaminants can be precursors of other effects such as survival, growth, or reproduction. However, these responses may be subtle, and measurement can be challenging. Using juvenile white sturgeon (Acipenser transmontanus) with copper exposures, this paper illustrates techniques used for quantifying behavioral responses using computer assisted video and digital image analysis. In previous studies severe impairments in swimming behavior were observed among early life stage white sturgeon during acute and chronic exposures to copper. Sturgeon behavior was rapidly impaired and to the extent that survival in the field would be jeopardized, as fish would be swept downstream, or readily captured by predators. The objectives of this investigation were to illustrate protocols to quantify swimming activity during a series of acute copper exposures to determine time to effect during early lifestage development, and to understand the significance of these responses relative to survival of these vulnerable early lifestage fish. With mortality being on a time continuum, determining when copper first affects swimming ability helps us to understand the implications for population level effects. The techniques used are readily adaptable to experimental designs with other organisms and stressors. PMID:26967350

  15. Roles of universal three-dimensional image analysis devices that assist surgical operations.

    PubMed

    Sakamoto, Tsuyoshi

    2014-04-01

    The circumstances surrounding medical image analysis have undergone rapid evolution. In such a situation, it can be said that "imaging" obtained through medical imaging modality and the "analysis" that we employ have become amalgamated. Recently, we feel the distance between "imaging" and "analysis" has become closer regarding the imaging analysis of any organ system, as if both terms mentioned above have become integrated. The history of medical image analysis started with the appearance of the computer. The invention of multi-planar reconstruction (MPR) used in the helical scan had a significant impact and became the basis for recent image analysis. Subsequently, curbed MPR (CPR) and other methods were developed, and the 3D diagnostic imaging and image analysis of the human body have started on a full scale. Volume rendering: the development of a new rendering algorithm and the significant improvement of memory and CPUs contributed to the development of "volume rendering," which allows 3D views with retained internal information. A new value was created by this development; computed tomography (CT) images that used to be for "diagnosis" before that time have become "applicable to treatment." In the past, before the development of volume rendering, a clinician had to mentally reconstruct an image reconfigured for diagnosis into a 3D image, but these developments have allowed the depiction of a 3D image on a monitor. Current technology: Currently, in Japan, the estimation of the liver volume and the perfusion area of the portal vein and hepatic vein are vigorously being adopted during preoperative planning for hepatectomy. Such a circumstance seems to be brought by the substantial improvement of said basic techniques and by upgrading the user interface, allowing doctors easy manipulation by themselves. The following describes the specific techniques. Future of post-processing technology: It is expected, in terms of the role of image analysis, for better or worse, that computer-aided diagnosis (CAD) will develop to a highly advanced level in every diagnostic field. Further, it is also expected in the treatment field that a technique coordinating various devices will be strongly required as a surgery navigator. Actually, surgery using an image navigator is being widely studied, and coordination with hardware, including robots, will also be developed. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  16. Distribution quantification on dermoscopy images for computer-assisted diagnosis of cutaneous melanomas.

    PubMed

    Liu, Zhao; Sun, Jiuai; Smith, Lyndon; Smith, Melvyn; Warr, Robert

    2012-05-01

    Computerised analysis on skin lesion images has been reported to be helpful in achieving objective and reproducible diagnosis of melanoma. In particular, asymmetry in shape, colour and structure reflects the irregular growth of melanin under the skin and is of great importance for diagnosing the malignancy of skin lesions. This paper proposes a novel asymmetry analysis based on a newly developed pigmentation elevation model and the global point signatures (GPSs). Specifically, the pigmentation elevation model was first constructed by computer-based analysis of dermoscopy images, for the identification of melanin and haemoglobin. Asymmetry of skin lesions was then assessed through quantifying distributions of the pigmentation elevation model using the GPSs, derived from a Laplace-Beltrami operator. This new approach allows quantifying the shape and pigmentation distributions of cutaneous lesions simultaneously. Algorithm performance was tested on 351 dermoscopy images, including 88 malignant melanomas and 263 benign naevi, employing a support vector machine (SVM) with tenfold cross-validation strategy. Competitive diagnostic results were achieved using the proposed asymmetry descriptor only, presenting 86.36 % sensitivity, 82.13 % specificity and overall 83.43 % accuracy, respectively. In addition, the proposed GPS-based asymmetry analysis enables working on dermoscopy images from different databases and is approved to be inherently robust to the external imaging variations. These advantages suggested that the proposed method has good potential for follow-up treatment.

  17. Development and Evaluation of an Interactive Computer-Assisted Learning Program--A Novel Approach to Teaching Gynaecological Surgery.

    ERIC Educational Resources Information Center

    Jha, Vikram; Widdowson, Shelley; Duffy, Sean

    2002-01-01

    Discusses computer-assisted learning (CAL) in medical education and describes the development of an interactive CAL program on CD-ROM, combining video, illustrations, and three-dimensional images, to enhance understanding of vaginal hysterectomy in terms of the anatomy and steps of the surgical procedure. (Author/LRW)

  18. Document authentication at molecular levels using desorption atmospheric pressure chemical ionization mass spectrometry imaging.

    PubMed

    Li, Ming; Jia, Bin; Ding, Liying; Hong, Feng; Ouyang, Yongzhong; Chen, Rui; Zhou, Shumin; Chen, Huanwen; Fang, Xiang

    2013-09-01

    Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI-MS), which was operated in either a gasless, solvent-free or methanol vapor-assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI-MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI-MS imaging differentiated a 10-min old from two 4 h old samples. Non-destructive forensic analysis of forged signatures either handwritten or computer-assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI-MS. The experimental results show that DAPCI-MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.

  19. Computer-assisted stereotactic neurological surgery: pre-planning and on-site real-time operating control and simulation system

    NASA Astrophysics Data System (ADS)

    Zamorano, Lucia J.; Jiang, Charlie Z. W.

    1993-09-01

    In this decade the concept and development of computer assisted stereotactic neurological surgery has improved dramatically. First, the computer network replaced the tape as the data transportation media. Second, newer systems include multi-modality image correlation and frameless stereotactics as an integral part of their functionality, and offer extensive assistance to the neurosurgeon from the preplanning stages to and throughout the operation itself. These are very important changes, and have spurred the development of many interesting techniques. Successful systems include the ISG and NSPS-3.0.

  20. Quantitative Analysis of Rat Dorsal Root Ganglion Neurons Cultured on Microelectrode Arrays Based on Fluorescence Microscopy Image Processing.

    PubMed

    Mari, João Fernando; Saito, José Hiroki; Neves, Amanda Ferreira; Lotufo, Celina Monteiro da Cruz; Destro-Filho, João-Batista; Nicoletti, Maria do Carmo

    2015-12-01

    Microelectrode Arrays (MEA) are devices for long term electrophysiological recording of extracellular spontaneous or evocated activities on in vitro neuron culture. This work proposes and develops a framework for quantitative and morphological analysis of neuron cultures on MEAs, by processing their corresponding images, acquired by fluorescence microscopy. The neurons are segmented from the fluorescence channel images using a combination of segmentation by thresholding, watershed transform, and object classification. The positioning of microelectrodes is obtained from the transmitted light channel images using the circular Hough transform. The proposed method was applied to images of dissociated culture of rat dorsal root ganglion (DRG) neuronal cells. The morphological and topological quantitative analysis carried out produced information regarding the state of culture, such as population count, neuron-to-neuron and neuron-to-microelectrode distances, soma morphologies, neuron sizes, neuron and microelectrode spatial distributions. Most of the analysis of microscopy images taken from neuronal cultures on MEA only consider simple qualitative analysis. Also, the proposed framework aims to standardize the image processing and to compute quantitative useful measures for integrated image-signal studies and further computational simulations. As results show, the implemented microelectrode identification method is robust and so are the implemented neuron segmentation and classification one (with a correct segmentation rate up to 84%). The quantitative information retrieved by the method is highly relevant to assist the integrated signal-image study of recorded electrophysiological signals as well as the physical aspects of the neuron culture on MEA. Although the experiments deal with DRG cell images, cortical and hippocampal cell images could also be processed with small adjustments in the image processing parameter estimation.

  1. Body hair counts during hair length reduction procedures: a comparative study between Computer Assisted Image Analysis after Manual Processing (CAIAMP) and Trichoscan(™).

    PubMed

    Van Neste, D J J

    2015-08-01

    To compare two measurement methods for body hair. Calibration of computer assisted image analysis after manual processing (CAIAMP) showed variation <4% for thickness and <2.3% for densities. Images from 6 body sites with 'good natural contrast between hair and skin' were taken before hair dye, after hair dye or after hair length reduction without hair extraction or destruction. Data in the same targets were compared with Trichoscan(™) quoted for 'unambiguous evaluation of the hair growth after shaving'. CAIAMP detected a total of 337 hair and showed no statistically significant differences with the three procedures confirming 'good natural contrast between hair and skin' and that reduction methods did not affect hair counts. While CAIAMP found a mean number of 19 thick hair (≥30 μm) before dye, 18 after dye and 20 after hair reduction, Trichoscan(™) found in the same sites respectively 44, 73 and 61. Trichoscan(™) generated counts differed statistically significantly from CAIAMP-data. Automated analyses were considered un-specifically influenced by hair medulla and natural or artificial skin background. Quality control including all steps of human intervention and measurement technology are mandatory for body hair measurements during experimental or clinical trials on body hair grooming, shaving or removal. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. New breast cancer prognostic factors identified by computer-aided image analysis of HE stained histopathology images

    PubMed Central

    Chen, Jia-Mei; Qu, Ai-Ping; Wang, Lin-Wei; Yuan, Jing-Ping; Yang, Fang; Xiang, Qing-Ming; Maskey, Ninu; Yang, Gui-Fang; Liu, Juan; Li, Yan

    2015-01-01

    Computer-aided image analysis (CAI) can help objectively quantify morphologic features of hematoxylin-eosin (HE) histopathology images and provide potentially useful prognostic information on breast cancer. We performed a CAI workflow on 1,150 HE images from 230 patients with invasive ductal carcinoma (IDC) of the breast. We used a pixel-wise support vector machine classifier for tumor nests (TNs)-stroma segmentation, and a marker-controlled watershed algorithm for nuclei segmentation. 730 morphologic parameters were extracted after segmentation, and 12 parameters identified by Kaplan-Meier analysis were significantly associated with 8-year disease free survival (P < 0.05 for all). Moreover, four image features including TNs feature (HR 1.327, 95%CI [1.001 - 1.759], P = 0.049), TNs cell nuclei feature (HR 0.729, 95%CI [0.537 - 0.989], P = 0.042), TNs cell density (HR 1.625, 95%CI [1.177 - 2.244], P = 0.003), and stromal cell structure feature (HR 1.596, 95%CI [1.142 - 2.229], P = 0.006) were identified by multivariate Cox proportional hazards model to be new independent prognostic factors. The results indicated that CAI can assist the pathologist in extracting prognostic information from HE histopathology images for IDC. The TNs feature, TNs cell nuclei feature, TNs cell density, and stromal cell structure feature could be new prognostic factors. PMID:26022540

  3. 77 FR 12848 - Medicare Program; Solicitation of Independent Accrediting Organizations To Participate in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-02

    ...)(4)(B) (excluding x-ray, ultrasound, and fluoroscopy), as specified by the Secretary in consultation... imaging services as ``imaging and computer-assisted imaging services, including x-ray, ultrasound...

  4. Development and application of computer assisted optimal method for treatment of femoral neck fracture.

    PubMed

    Wang, Monan; Zhang, Kai; Yang, Ning

    2018-04-09

    To help doctors decide their treatment from the aspect of mechanical analysis, the work built a computer assisted optimal system for treatment of femoral neck fracture oriented to clinical application. The whole system encompassed the following three parts: Preprocessing module, finite element mechanical analysis module, post processing module. Preprocessing module included parametric modeling of bone, parametric modeling of fracture face, parametric modeling of fixed screw and fixed position and input and transmission of model parameters. Finite element mechanical analysis module included grid division, element type setting, material property setting, contact setting, constraint and load setting, analysis method setting and batch processing operation. Post processing module included extraction and display of batch processing operation results, image generation of batch processing operation, optimal program operation and optimal result display. The system implemented the whole operations from input of fracture parameters to output of the optimal fixed plan according to specific patient real fracture parameter and optimal rules, which demonstrated the effectiveness of the system. Meanwhile, the system had a friendly interface, simple operation and could improve the system function quickly through modifying single module.

  5. Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.

    PubMed

    Vaccaro, Calogero; Busetto, Roberto; Bernardini, Daniele; Anselmi, Carlo; Zotti, Alessandro

    2012-03-01

    To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specimen was subsequently scanned by use of the same DEXA equipment. The BMD values resulting from each DEXA scan were paired with the MGVs obtained by use of software on the corresponding digitalized or digital radiographic image. The MGV analysis of digitalized and digital x-ray images was a precise (coefficient of variation, 0.1 and 0.09, respectively) and highly accurate method for assessing BMD, compared with DEXA (correlation coefficient, 0.910 and 0.937 for conventional and digital radiography, respectively). The high correlation between MGV and BMD indicated that MGV analysis may be a reliable alternative to DEXA in assessing radiographic bone density. This may provide a new, inexpensive, and readily available estimate of BMD.

  6. Graphics Processing Unit Assisted Thermographic Compositing

    NASA Technical Reports Server (NTRS)

    Ragasa, Scott; Russell, Samuel S.

    2012-01-01

    Objective Develop a software application utilizing high performance computing techniques, including general purpose graphics processing units (GPGPUs), for the analysis and visualization of large thermographic data sets. Over the past several years, an increasing effort among scientists and engineers to utilize graphics processing units (GPUs) in a more general purpose fashion is allowing for previously unobtainable levels of computation by individual workstations. As data sets grow, the methods to work them grow at an equal, and often greater, pace. Certain common computations can take advantage of the massively parallel and optimized hardware constructs of the GPU which yield significant increases in performance. These common computations have high degrees of data parallelism, that is, they are the same computation applied to a large set of data where the result does not depend on other data elements. Image processing is one area were GPUs are being used to greatly increase the performance of certain analysis and visualization techniques.

  7. Self-learning computers for surgical planning and prediction of postoperative alignment.

    PubMed

    Lafage, Renaud; Pesenti, Sébastien; Lafage, Virginie; Schwab, Frank J

    2018-02-01

    In past decades, the role of sagittal alignment has been widely demonstrated in the setting of spinal conditions. As several parameters can be affected, identifying the driver of the deformity is the cornerstone of a successful treatment approach. Despite the importance of restoring sagittal alignment for optimizing outcome, this task remains challenging. Self-learning computers and optimized algorithms are of great interest in spine surgery as in that they facilitate better planning and prediction of postoperative alignment. Nowadays, computer-assisted tools are part of surgeons' daily practice; however, the use of such tools remains to be time-consuming. NARRATIVE REVIEW AND RESULTS: Computer-assisted methods for the prediction of postoperative alignment consist of a three step analysis: identification of anatomical landmark, definition of alignment objectives, and simulation of surgery. Recently, complex rules for the prediction of alignment have been proposed. Even though this kind of work leads to more personalized objectives, the number of parameters involved renders it difficult for clinical use, stressing the importance of developing computer-assisted tools. The evolution of our current technology, including machine learning and other types of advanced algorithms, will provide powerful tools that could be useful in improving surgical outcomes and alignment prediction. These tools can combine different types of advanced technologies, such as image recognition and shape modeling, and using this technique, computer-assisted methods are able to predict spinal shape. The development of powerful computer-assisted methods involves the integration of several sources of information such as radiographic parameters (X-rays, MRI, CT scan, etc.), demographic information, and unusual non-osseous parameters (muscle quality, proprioception, gait analysis data). In using a larger set of data, these methods will aim to mimic what is actually done by spine surgeons, leading to real tailor-made solutions. Integrating newer technology can change the current way of planning/simulating surgery. The use of powerful computer-assisted tools that are able to integrate several parameters and learn from experience can change the traditional way of selecting treatment pathways and counseling patients. However, there is still much work to be done to reach a desired level as noted in other orthopedic fields, such as hip surgery. Many of these tools already exist in non-medical fields and their adaptation to spine surgery is of considerable interest.

  8. Comparative analysis of image classification methods for automatic diagnosis of ophthalmic images

    NASA Astrophysics Data System (ADS)

    Wang, Liming; Zhang, Kai; Liu, Xiyang; Long, Erping; Jiang, Jiewei; An, Yingying; Zhang, Jia; Liu, Zhenzhen; Lin, Zhuoling; Li, Xiaoyan; Chen, Jingjing; Cao, Qianzhong; Li, Jing; Wu, Xiaohang; Wang, Dongni; Li, Wangting; Lin, Haotian

    2017-01-01

    There are many image classification methods, but it remains unclear which methods are most helpful for analyzing and intelligently identifying ophthalmic images. We select representative slit-lamp images which show the complexity of ocular images as research material to compare image classification algorithms for diagnosing ophthalmic diseases. To facilitate this study, some feature extraction algorithms and classifiers are combined to automatic diagnose pediatric cataract with same dataset and then their performance are compared using multiple criteria. This comparative study reveals the general characteristics of the existing methods for automatic identification of ophthalmic images and provides new insights into the strengths and shortcomings of these methods. The relevant methods (local binary pattern +SVMs, wavelet transformation +SVMs) which achieve an average accuracy of 87% and can be adopted in specific situations to aid doctors in preliminarily disease screening. Furthermore, some methods requiring fewer computational resources and less time could be applied in remote places or mobile devices to assist individuals in understanding the condition of their body. In addition, it would be helpful to accelerate the development of innovative approaches and to apply these methods to assist doctors in diagnosing ophthalmic disease.

  9. Phenotype detection in morphological mutant mice using deformation features.

    PubMed

    Roy, Sharmili; Liang, Xi; Kitamoto, Asanobu; Tamura, Masaru; Shiroishi, Toshihiko; Brown, Michael S

    2013-01-01

    Large-scale global efforts are underway to knockout each of the approximately 25,000 mouse genes and interpret their roles in shaping the mammalian embryo. Given the tremendous amount of data generated by imaging mutated prenatal mice, high-throughput image analysis systems are inevitable to characterize mammalian development and diseases. Current state-of-the-art computational systems offer only differential volumetric analysis of pre-defined anatomical structures between various gene-knockout mice strains. For subtle anatomical phenotypes, embryo phenotyping still relies on the laborious histological techniques that are clearly unsuitable in such big data environment. This paper presents a system that automatically detects known phenotypes and assists in discovering novel phenotypes in muCT images of mutant mice. Deformation features obtained from non-linear registration of mutant embryo to a normal consensus average image are extracted and analyzed to compute phenotypic and candidate phenotypic areas. The presented system is evaluated using C57BL/10 embryo images. All cases of ventricular septum defect and polydactyly, well-known to be present in this strain, are successfully detected. The system predicts potential phenotypic areas in the liver that are under active histological evaluation for possible phenotype of this mouse line.

  10. A comparison of basic deinterlacing approaches for a computer assisted diagnosis approach of videoscope images

    NASA Astrophysics Data System (ADS)

    Kage, Andreas; Canto, Marcia; Gorospe, Emmanuel; Almario, Antonio; Münzenmayer, Christian

    2010-03-01

    In the near future, Computer Assisted Diagnosis (CAD) which is well known in the area of mammography might be used to support clinical experts in the diagnosis of images derived from imaging modalities such as endoscopy. In the recent past, a few first approaches for computer assisted endoscopy have been presented already. These systems use a video signal as an input that is provided by the endoscopes video processor. Despite the advent of high-definition systems most standard endoscopy systems today still provide only analog video signals. These signals consist of interlaced images that can not be used in a CAD approach without deinterlacing. Of course, there are many different deinterlacing approaches known today. But most of them are specializations of some basic approaches. In this paper we present four basic deinterlacing approaches. We have used a database of non-interlaced images which have been degraded by artificial interlacing and afterwards processed by these approaches. The database contains regions of interest (ROI) of clinical relevance for the diagnosis of abnormalities in the esophagus. We compared the classification rates on these ROIs on the original images and after the deinterlacing. The results show that the deinterlacing has an impact on the classification rates. The Bobbing approach and the Motion Compensation approach achieved the best classification results in most cases.

  11. [Application of computer-assisted 3D imaging simulation for surgery].

    PubMed

    Matsushita, S; Suzuki, N

    1994-03-01

    This article describes trends in application of various imaging technology in surgical planning, navigation, and computer aided surgery. Imaging information is essential factor for simulation in medicine. It includes three dimensional (3D) image reconstruction, neuro-surgical navigation, creating substantial model based on 3D imaging data and etc. These developments depend mostly on 3D imaging technique, which is much contributed by recent computer technology. 3D imaging can offer new intuitive information to physician and surgeon, and this method is suitable for mechanical control. By utilizing simulated results, we can obtain more precise surgical orientation, estimation, and operation. For more advancement, automatic and high speed recognition of medical imaging is being developed.

  12. SU-F-J-94: Development of a Plug-in Based Image Analysis Tool for Integration Into Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, D; Anderson, C; Mayo, C

    Purpose: To extend the functionality of a commercial treatment planning system (TPS) to support (i) direct use of quantitative image-based metrics within treatment plan optimization and (ii) evaluation of dose-functional volume relationships to assist in functional image adaptive radiotherapy. Methods: A script was written that interfaces with a commercial TPS via an Application Programming Interface (API). The script executes a program that performs dose-functional volume analyses. Written in C#, the script reads the dose grid and correlates it with image data on a voxel-by-voxel basis through API extensions that can access registration transforms. A user interface was designed through WinFormsmore » to input parameters and display results. To test the performance of this program, image- and dose-based metrics computed from perfusion SPECT images aligned to the treatment planning CT were generated, validated, and compared. Results: The integration of image analysis information was successfully implemented as a plug-in to a commercial TPS. Perfusion SPECT images were used to validate the calculation and display of image-based metrics as well as dose-intensity metrics and histograms for defined structures on the treatment planning CT. Various biological dose correction models, custom image-based metrics, dose-intensity computations, and dose-intensity histograms were applied to analyze the image-dose profile. Conclusion: It is possible to add image analysis features to commercial TPSs through custom scripting applications. A tool was developed to enable the evaluation of image-intensity-based metrics in the context of functional targeting and avoidance. In addition to providing dose-intensity metrics and histograms that can be easily extracted from a plan database and correlated with outcomes, the system can also be extended to a plug-in optimization system, which can directly use the computed metrics for optimization of post-treatment tumor or normal tissue response models. Supported by NIH - P01 - CA059827.« less

  13. Computer-assisted abdominal surgery: new technologies.

    PubMed

    Kenngott, H G; Wagner, M; Nickel, F; Wekerle, A L; Preukschas, A; Apitz, M; Schulte, T; Rempel, R; Mietkowski, P; Wagner, F; Termer, A; Müller-Stich, Beat P

    2015-04-01

    Computer-assisted surgery is a wide field of technologies with the potential to enable the surgeon to improve efficiency and efficacy of diagnosis, treatment, and clinical management. This review provides an overview of the most important new technologies and their applications. A MEDLINE database search was performed revealing a total of 1702 references. All references were considered for information on six main topics, namely image guidance and navigation, robot-assisted surgery, human-machine interface, surgical processes and clinical pathways, computer-assisted surgical training, and clinical decision support. Further references were obtained through cross-referencing the bibliography cited in each work. Based on their respective field of expertise, the authors chose 64 publications relevant for the purpose of this review. Computer-assisted systems are increasingly used not only in experimental studies but also in clinical studies. Although computer-assisted abdominal surgery is still in its infancy, the number of studies is constantly increasing, and clinical studies start showing the benefits of computers used not only as tools of documentation and accounting but also for directly assisting surgeons during diagnosis and treatment of patients. Further developments in the field of clinical decision support even have the potential of causing a paradigm shift in how patients are diagnosed and treated.

  14. Why care about linear hair growth rates (LHGR)? a study using in vivo imaging and computer assisted image analysis after manual processing (CAIAMP) in unaffected male controls and men with male pattern hair loss (MPHL).

    PubMed

    Van Neste, Dominique

    2014-01-01

    The words "hair growth" frequently encompass many aspects other than just growth. Report on a validation method for precise non-invasive measurement of thickness together with linear hair growth rates of individual hair fibres. To verify the possible correlation between thickness and linear growth rate of scalp hair in male pattern hair loss as compared with healthy male controls. To document the process of validation of hair growth measurement from in vivo image capturing and manual processing, followed by computer assisted image analysis. We analysed 179 paired images obtained with the contrast-enhanced-phototrichogram method with exogen collection (CE-PTG-EC) in 13 healthy male controls and in 87 men with male pattern hair loss (MPHL). There was a global positive correlation between thickness and growth rate (ANOVA; p<0.0001) and a statistically significantly (ANOVA; p<0.0005) slower growth rate in MPHL as compared with equally thick hairs from controls. Finally, the growth rate recorded in the more severe patterns was significantly (ANOVA; P ≤ 0.001) reduced compared with equally thick hair from less severely affected MPHL or controls subjects. Reduced growth rate, together with thinning and shortening of the anagen phase duration in MPHL might contribute together to the global impression of decreased hair volume on the top of the head. Amongst other structural and functional parameters characterizing hair follicle regression, linear hair growth rate warrants further investigation, as it may be relevant in terms of self-perception of hair coverage, quantitative diagnosis and prognostic factor of the therapeutic response.

  15. On the integral use of foundational concepts in verifying validity during skull-photo superimposition.

    PubMed

    Jayaprakash, Paul T

    2017-09-01

    Often cited reliability test on video superimposition method integrated scaling face-images in relation to skull-images, tragus-auditory meatus relationship in addition to exocanthion-Whitnall's tubercle relationship when orientating the skull-image and wipe mode imaging in addition to mix mode imaging when obtaining skull-face image overlay and evaluating the goodness of match. However, a report that found higher false positive matches in computer assisted superimposition method transited from the above foundational concepts and relied on images of unspecified sizes that are lesser than 'life-size', frontal plane landmarks in the skull- and face- images alone for orientating the skull-image and mix images alone for evaluating the goodness of match. Recently, arguing the use of 'life-size' images as 'archaic', the authors who tested the reliability in the computer assisted superimposition method have denied any method transition. This article describes that the use of images of unspecified sizes at lesser than 'life-size' eliminates the only possibility to quantify parameters during superimposition which alone enables dynamic skull orientation when overlaying a skull-image with a face-image in an anatomically acceptable orientation. The dynamic skull orientation process mandatorily requires aligning the tragus in the 2D face-image with the auditory meatus in the 3D skull-image for anatomically orientating the skull-image in relation to the posture in the face-image, a step not mentioned by the authors describing the computer assisted superimposition method. Furthermore, mere reliance on mix type images during image overlay eliminates the possibility to assess the relationship between the leading edges of the skull- and face-image outlines as also specific area match among the corresponding craniofacial organs during superimposition. Indicating the possibility of increased false positive matches as a consequence of the above method transitions, the need for testing the reliability in the superimposition method adopting concepts that are considered safe is stressed. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Computer vision for driver assistance systems

    NASA Astrophysics Data System (ADS)

    Handmann, Uwe; Kalinke, Thomas; Tzomakas, Christos; Werner, Martin; von Seelen, Werner

    1998-07-01

    Systems for automated image analysis are useful for a variety of tasks and their importance is still increasing due to technological advances and an increase of social acceptance. Especially in the field of driver assistance systems the progress in science has reached a level of high performance. Fully or partly autonomously guided vehicles, particularly for road-based traffic, pose high demands on the development of reliable algorithms due to the conditions imposed by natural environments. At the Institut fur Neuroinformatik, methods for analyzing driving relevant scenes by computer vision are developed in cooperation with several partners from the automobile industry. We introduce a system which extracts the important information from an image taken by a CCD camera installed at the rear view mirror in a car. The approach consists of a sequential and a parallel sensor and information processing. Three main tasks namely the initial segmentation (object detection), the object tracking and the object classification are realized by integration in the sequential branch and by fusion in the parallel branch. The main gain of this approach is given by the integrative coupling of different algorithms providing partly redundant information.

  17. Clinical relevance of model based computer-assisted diagnosis and therapy

    NASA Astrophysics Data System (ADS)

    Schenk, Andrea; Zidowitz, Stephan; Bourquain, Holger; Hindennach, Milo; Hansen, Christian; Hahn, Horst K.; Peitgen, Heinz-Otto

    2008-03-01

    The ability to acquire and store radiological images digitally has made this data available to mathematical and scientific methods. With the step from subjective interpretation to reproducible measurements and knowledge, it is also possible to develop and apply models that give additional information which is not directly visible in the data. In this context, it is important to know the characteristics and limitations of each model. Four characteristics assure the clinical relevance of models for computer-assisted diagnosis and therapy: ability of patient individual adaptation, treatment of errors and uncertainty, dynamic behavior, and in-depth evaluation. We demonstrate the development and clinical application of a model in the context of liver surgery. Here, a model for intrahepatic vascular structures is combined with individual, but in the degree of vascular details limited anatomical information from radiological images. As a result, the model allows for a dedicated risk analysis and preoperative planning of oncologic resections as well as for living donor liver transplantations. The clinical relevance of the method was approved in several evaluation studies of our medical partners and more than 2900 complex surgical cases have been analyzed since 2002.

  18. Computer-assisted diagnosis of melanoma.

    PubMed

    Fuller, Collin; Cellura, A Paul; Hibler, Brian P; Burris, Katy

    2016-03-01

    The computer-assisted diagnosis of melanoma is an exciting area of research where imaging techniques are combined with diagnostic algorithms in an attempt to improve detection and outcomes for patients with skin lesions suspicious for malignancy. Once an image has been acquired, it undergoes a processing pathway which includes preprocessing, enhancement, segmentation, feature extraction, feature selection, change detection, and ultimately classification. Practicality for everyday clinical use remains a vital question. A successful model must obtain results that are on par or outperform experienced dermatologists, keep costs at a minimum, be user-friendly, and be time efficient with high sensitivity and specificity. ©2015 Frontline Medical Communications.

  19. Computer-assisted sperm analysis (CASA): capabilities and potential developments.

    PubMed

    Amann, Rupert P; Waberski, Dagmar

    2014-01-01

    Computer-assisted sperm analysis (CASA) systems have evolved over approximately 40 years, through advances in devices to capture the image from a microscope, huge increases in computational power concurrent with amazing reduction in size of computers, new computer languages, and updated/expanded software algorithms. Remarkably, basic concepts for identifying sperm and their motion patterns are little changed. Older and slower systems remain in use. Most major spermatology laboratories and semen processing facilities have a CASA system, but the extent of reliance thereon ranges widely. This review describes capabilities and limitations of present CASA technology used with boar, bull, and stallion sperm, followed by possible future developments. Each marketed system is different. Modern CASA systems can automatically view multiple fields in a shallow specimen chamber to capture strobe-like images of 500 to >2000 sperm, at 50 or 60 frames per second, in clear or complex extenders, and in <2 minutes, store information for ≥ 30 frames and provide summary data for each spermatozoon and the population. A few systems evaluate sperm morphology concurrent with motion. CASA cannot accurately predict 'fertility' that will be obtained with a semen sample or subject. However, when carefully validated, current CASA systems provide information important for quality assurance of semen planned for marketing, and for the understanding of the diversity of sperm responses to changes in the microenvironment in research. The four take-home messages from this review are: (1) animal species, extender or medium, specimen chamber, intensity of illumination, imaging hardware and software, instrument settings, technician, etc., all affect accuracy and precision of output values; (2) semen production facilities probably do not need a substantially different CASA system whereas biology laboratories would benefit from systems capable of imaging and tracking sperm in deep chambers for a flexible period of time; (3) software should enable grouping of individual sperm based on one or more attributes so outputs reflect subpopulations or clusters of similar sperm with unique properties; means or medians for the total population are insufficient; and (4) a field-use, portable CASA system for measuring one motion and two or three morphology attributes of individual sperm is needed for field theriogenologists or andrologists working with human sperm outside urban centers; appropriate hardware to capture images and process data apparently are available. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Studies Related to Computer-Assisted Instruction. Semi-Annual Progress Report on Contract Nonr-624(18) October 1, 1968 through March 31, 1969.

    ERIC Educational Resources Information Center

    Glaser, Robert

    A study of response latency in a drill-and-practice task showed that variability in latency measures could be reduced by the use of self-pacing procedures, but not by the detailed analysis of latency into separate components. Experiments carried out on instructional history variables in teaching a mirror image, oblique line discrimination, showed…

  1. Computer-Aided Diagnosis in Medical Imaging: Historical Review, Current Status and Future Potential

    PubMed Central

    Doi, Kunio

    2007-01-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a “second opinion” and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists’ accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of interstitial lung diseases. In order to assist in the differential diagnosis, it would be possible to search for and retrieve images (or lesions) with known pathology, which would be very similar to a new unknown case, from PACS when a reliable and useful method has been developed for quantifying the similarity of a pair of images for visual comparison by radiologists. PMID:17349778

  2. [A computer tomography assisted method for the automatic detection of region of interest in dynamic kidney images].

    PubMed

    Jing, Xueping; Zheng, Xiujuan; Song, Shaoli; Liu, Kai

    2017-12-01

    Glomerular filtration rate (GFR), which can be estimated by Gates method with dynamic kidney single photon emission computed tomography (SPECT) imaging, is a key indicator of renal function. In this paper, an automatic computer tomography (CT)-assisted detection method of kidney region of interest (ROI) is proposed to achieve the objective and accurate GFR calculation. In this method, the CT coronal projection image and the enhanced SPECT synthetic image are firstly generated and registered together. Then, the kidney ROIs are delineated using a modified level set algorithm. Meanwhile, the background ROIs are also obtained based on the kidney ROIs. Finally, the value of GFR is calculated via Gates method. Comparing with the clinical data, the GFR values estimated by the proposed method were consistent with the clinical reports. This automatic method can improve the accuracy and stability of kidney ROI detection for GFR calculation, especially when the kidney function has been severely damaged.

  3. Image-Based Predictive Modeling of Heart Mechanics.

    PubMed

    Wang, V Y; Nielsen, P M F; Nash, M P

    2015-01-01

    Personalized biophysical modeling of the heart is a useful approach for noninvasively analyzing and predicting in vivo cardiac mechanics. Three main developments support this style of analysis: state-of-the-art cardiac imaging technologies, modern computational infrastructure, and advanced mathematical modeling techniques. In vivo measurements of cardiac structure and function can be integrated using sophisticated computational methods to investigate mechanisms of myocardial function and dysfunction, and can aid in clinical diagnosis and developing personalized treatment. In this article, we review the state-of-the-art in cardiac imaging modalities, model-based interpretation of 3D images of cardiac structure and function, and recent advances in modeling that allow personalized predictions of heart mechanics. We discuss how using such image-based modeling frameworks can increase the understanding of the fundamental biophysics behind cardiac mechanics, and assist with diagnosis, surgical guidance, and treatment planning. Addressing the challenges in this field will require a coordinated effort from both the clinical-imaging and modeling communities. We also discuss future directions that can be taken to bridge the gap between basic science and clinical translation.

  4. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    PubMed

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  5. Computer assisted detection and analysis of tall cell variant papillary thyroid carcinoma in histological images

    NASA Astrophysics Data System (ADS)

    Kim, Edward; Baloch, Zubair; Kim, Caroline

    2015-03-01

    The number of new cases of thyroid cancer are dramatically increasing as incidences of this cancer have more than doubled since the early 1970s. Tall cell variant (TCV-PTC) papillary thyroid carcinoma is one type of thyroid cancer that is more aggressive and usually associated with higher local recurrence and distant metastasis. This variant can be identified through visual characteristics of cells in histological images. Thus, we created a fully automatic algorithm that is able to segment cells using a multi-stage approach. Our method learns the statistical characteristics of nuclei and cells during the segmentation process and utilizes this information for a more accurate result. Furthermore, we are able to analyze the detected regions and extract characteristic cell data that can be used to assist in clinical diagnosis.

  6. Machine-assisted analysis of Landsat data in the study of crop-soils relationships

    USGS Publications Warehouse

    Draeger, William C.

    1976-01-01

    To date, relatively few studies have dealt with crop-soil interactions as they affect the appearance of agricultural areas on Landsat imagery, and hence crop and soil classification or the analysis of agricultural land use.The Image 100, a computer-based data analysis system which allows an interpreter to interact directly and rapidly with Landsat computer compatible tape data, provided a tool to assist in the evaluation of the extent and significance of these interactions. Used with timely and accurate ground data, the system made possible a determination of the variability in crop spectral appearance, from soil type to soil type, as recorded on Landsat data. Information was provided in the form of spectral distribution histrograms for each crop-soil class on each Landsat band. Several crop categories in a test area in  rookings County, South Dakota, were classified using training fields that were selected to be representative of each major crop-soil class. Accuracies in each case, on a total acreage basis, were greater than 90 percent.

  7. Roundness variation in JPEG images affects the automated process of nuclear immunohistochemical quantification: correction with a linear regression model.

    PubMed

    López, Carlos; Jaén Martinez, Joaquín; Lejeune, Marylène; Escrivà, Patricia; Salvadó, Maria T; Pons, Lluis E; Alvaro, Tomás; Baucells, Jordi; García-Rojo, Marcial; Cugat, Xavier; Bosch, Ramón

    2009-10-01

    The volume of digital image (DI) storage continues to be an important problem in computer-assisted pathology. DI compression enables the size of files to be reduced but with the disadvantage of loss of quality. Previous results indicated that the efficiency of computer-assisted quantification of immunohistochemically stained cell nuclei may be significantly reduced when compressed DIs are used. This study attempts to show, with respect to immunohistochemically stained nuclei, which morphometric parameters may be altered by the different levels of JPEG compression, and the implications of these alterations for automated nuclear counts, and further, develops a method for correcting this discrepancy in the nuclear count. For this purpose, 47 DIs from different tissues were captured in uncompressed TIFF format and converted to 1:3, 1:23 and 1:46 compression JPEG images. Sixty-five positive objects were selected from these images, and six morphological parameters were measured and compared for each object in TIFF images and those of the different compression levels using a set of previously developed and tested macros. Roundness proved to be the only morphological parameter that was significantly affected by image compression. Factors to correct the discrepancy in the roundness estimate were derived from linear regression models for each compression level, thereby eliminating the statistically significant differences between measurements in the equivalent images. These correction factors were incorporated in the automated macros, where they reduced the nuclear quantification differences arising from image compression. Our results demonstrate that it is possible to carry out unbiased automated immunohistochemical nuclear quantification in compressed DIs with a methodology that could be easily incorporated in different systems of digital image analysis.

  8. Computer-Assisted Total Knee Arthroplasty: Is There a Difference Between Image-Based and Imageless Techniques?

    PubMed

    Tabatabaee, Reza M; Rasouli, Mohammad R; Maltenfort, Mitchell G; Fuino, Robert; Restrepo, Camilo; Oliashirazi, Ali

    2018-04-01

    Image-based and imageless computer-assisted total knee arthroplasty (CATKA) has become increasingly popular. This study aims to compare outcomes, including perioperative complications and transfusion rate, between CATKA and conventional total knee arthroplasty (TKA), as well as between image-based and imageless CATKA. Using the 9th revision of the International Classification of Diseases codes, we queried the Nationwide Inpatient Sample database from 2005 to 2011 to identify unilateral conventional TKA, image-based, and imageless CATKAs as well as in-hospital complications and transfusion rates. A total of 787,809 conventional TKAs and 13,246 CATKAs (1055 image-based and 12,191 imageless) were identified. The rate of CATKA increased 23.13% per year from 2005 to 2011. Transfusion rates in conventional TKA and CATKA cases were 11.73% and 8.20% respectively (P < .001) and 6.92% in image-based vs 8.27% in imageless (P = .023). Perioperative complications occurred in 4.50%, 3.47%, and 3.41% of cases after conventional, imageless, and imaged-based CATKAs, respectively. Using multivariate analysis, perioperative complications were significantly higher in conventional TKA compared to CATKA (odds ratio = 1.17, 95% confidence interval 1.03-1.33, P = .01). There was no significant difference between imageless and image-based CATKA (P = .34). Length of hospital stay and hospital charges were not significantly different between groups (P > .05). CATKA has low complication rates and may improve patient outcomes after TKA. CATKA, especially the image-based technique, may reduce in-hospital complications and transfusion without increasing hospital charges and length of hospital stay significantly. Large prospective studies with long follow-up are required to verify potential benefits of CATKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial.

    PubMed

    Leong, Natalie L; Buijze, Geert A; Fu, Eric C; Stockmans, Filip; Jupiter, Jesse B

    2010-12-14

    Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months postoperatively. Computer-assisted surgical planning, combined with patient-specific surgical guides, is a powerful new technology that has the potential to improve the accuracy and consistency of orthopaedic surgery. To date, the role of this technology in upper extremity surgery has not been adequately investigated, and it is unclear whether its use provides any significant clinical benefit over traditional preoperative imaging protocols. Our study will represent the first randomized controlled trial investigating the use of computer assisted surgery in corrective osteotomy for distal radius malunions. NCT01193010.

  10. A new set of wavelet- and fractals-based features for Gleason grading of prostate cancer histopathology images

    NASA Astrophysics Data System (ADS)

    Mosquera Lopez, Clara; Agaian, Sos

    2013-02-01

    Prostate cancer detection and staging is an important step towards patient treatment selection. Advancements in digital pathology allow the application of new quantitative image analysis algorithms for computer-assisted diagnosis (CAD) on digitized histopathology images. In this paper, we introduce a new set of features to automatically grade pathological images using the well-known Gleason grading system. The goal of this study is to classify biopsy images belonging to Gleason patterns 3, 4, and 5 by using a combination of wavelet and fractal features. For image classification we use pairwise coupling Support Vector Machine (SVM) classifiers. The accuracy of the system, which is close to 97%, is estimated through three different cross-validation schemes. The proposed system offers the potential for automating classification of histological images and supporting prostate cancer diagnosis.

  11. Graphics Processing Unit Assisted Thermographic Compositing

    NASA Technical Reports Server (NTRS)

    Ragasa, Scott; McDougal, Matthew; Russell, Sam

    2013-01-01

    Objective: To develop a software application utilizing general purpose graphics processing units (GPUs) for the analysis of large sets of thermographic data. Background: Over the past few years, an increasing effort among scientists and engineers to utilize the GPU in a more general purpose fashion is allowing for supercomputer level results at individual workstations. As data sets grow, the methods to work them grow at an equal, and often greater, pace. Certain common computations can take advantage of the massively parallel and optimized hardware constructs of the GPU to allow for throughput that was previously reserved for compute clusters. These common computations have high degrees of data parallelism, that is, they are the same computation applied to a large set of data where the result does not depend on other data elements. Signal (image) processing is one area were GPUs are being used to greatly increase the performance of certain algorithms and analysis techniques.

  12. Characterization of Atrophic Changes in the Cerebral Cortex Using Fractal Dimensional Analysis

    PubMed Central

    George, Anuh T.; Jeon, Tina; Hynan, Linda S.; Youn, Teddy S.; Kennedy, David N.; Dickerson, Bradford

    2010-01-01

    The purpose of this project is to apply a modified fractal analysis technique to high-resolution T1 weighted magnetic resonance images in order to quantify the alterations in the shape of the cerebral cortex that occur in patients with Alzheimer’s disease. Images were selected from the Alzheimer’s Disease Neuroimaging Initiative database (Control N=15, Mild-Moderate AD N=15). The images were segmented using a semi-automated analysis program. Four coronal and three axial profiles of the cerebral cortical ribbon were created. The fractal dimensions (Df) of the cortical ribbons were then computed using a box-counting algorithm. The mean Df of the cortical ribbons from AD patients were lower than age-matched controls on six of seven profiles. The fractal measure has regional variability which reflects local differences in brain structure. Fractal dimension is complementary to volumetric measures and may assist in identifying disease state or disease progression. PMID:20740072

  13. Computer-Assisted Culture Learning in an Online Augmented Reality Environment Based on Free-Hand Gesture Interaction

    ERIC Educational Resources Information Center

    Yang, Mau-Tsuen; Liao, Wan-Che

    2014-01-01

    The physical-virtual immersion and real-time interaction play an essential role in cultural and language learning. Augmented reality (AR) technology can be used to seamlessly merge virtual objects with real-world images to realize immersions. Additionally, computer vision (CV) technology can recognize free-hand gestures from live images to enable…

  14. Three-dimensional segmentation of the tumor mass in computed tomographic images of neuroblastoma

    NASA Astrophysics Data System (ADS)

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Boag, Graham S.

    2004-05-01

    Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, fibrosis, and normal tissue are often intermixed. Rather than attempt to separate these tissue types into distinct regions, we propose to explore methods to delineate the normal structures expected in abdominal CT images, remove them from further consideration, and examine the remaining parts of the images for the tumor mass. We explore the use of fuzzy connectivity for this purpose. Expert knowledge provided by the radiologist in the form of the expected structures and their shapes, HU values, and radiological characteristics are also incorporated in the segmentation algorithm. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative assessment of the response to chemotherapy and in the planning of delayed surgery for resection of the tumor. The performance of the algorithm is evaluated using cases acquired from the Alberta Children's Hospital.

  15. 75 FR 4088 - Medicare Program; Approval of Independent Accrediting Organizations To Participate in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ...) (excluding x-ray, ultrasound, and fluoroscopy), as specified by the Secretary in consultation with physician... ``imaging and computer-assisted imaging services, including x-ray, ultrasound (including echocardiography...

  16. PathoSpotter-K: A computational tool for the automatic identification of glomerular lesions in histological images of kidneys

    NASA Astrophysics Data System (ADS)

    Barros, George O.; Navarro, Brenda; Duarte, Angelo; Dos-Santos, Washington L. C.

    2017-04-01

    PathoSpotter is a computational system designed to assist pathologists in teaching about and researching kidney diseases. PathoSpotter-K is the version that was developed to detect nephrological lesions in digital images of kidneys. Here, we present the results obtained using the first version of PathoSpotter-K, which uses classical image processing and pattern recognition methods to detect proliferative glomerular lesions with an accuracy of 88.3 ± 3.6%. Such performance is only achieved by similar systems if they use images of cell in contexts that are much less complex than the glomerular structure. The results indicate that the approach can be applied to the development of systems designed to train pathology students and to assist pathologists in determining large-scale clinicopathological correlations in morphological research.

  17. Graphics Processing Unit Assisted Thermographic Compositing

    NASA Technical Reports Server (NTRS)

    Ragasa, Scott; McDougal, Matthew; Russell, Sam

    2012-01-01

    Objective: To develop a software application utilizing general purpose graphics processing units (GPUs) for the analysis of large sets of thermographic data. Background: Over the past few years, an increasing effort among scientists and engineers to utilize the GPU in a more general purpose fashion is allowing for supercomputer level results at individual workstations. As data sets grow, the methods to work them grow at an equal, and often great, pace. Certain common computations can take advantage of the massively parallel and optimized hardware constructs of the GPU to allow for throughput that was previously reserved for compute clusters. These common computations have high degrees of data parallelism, that is, they are the same computation applied to a large set of data where the result does not depend on other data elements. Signal (image) processing is one area were GPUs are being used to greatly increase the performance of certain algorithms and analysis techniques. Technical Methodology/Approach: Apply massively parallel algorithms and data structures to the specific analysis requirements presented when working with thermographic data sets.

  18. LOCAL ORTHOGONAL CUTTING METHOD FOR COMPUTING MEDIAL CURVES AND ITS BIOMEDICAL APPLICATIONS

    PubMed Central

    Einstein, Daniel R.; Dyedov, Vladimir

    2010-01-01

    Medial curves have a wide range of applications in geometric modeling and analysis (such as shape matching) and biomedical engineering (such as morphometry and computer assisted surgery). The computation of medial curves poses significant challenges, both in terms of theoretical analysis and practical efficiency and reliability. In this paper, we propose a definition and analysis of medial curves and also describe an efficient and robust method called local orthogonal cutting (LOC) for computing medial curves. Our approach is based on three key concepts: a local orthogonal decomposition of objects into substructures, a differential geometry concept called the interior center of curvature (ICC), and integrated stability and consistency tests. These concepts lend themselves to robust numerical techniques and result in an algorithm that is efficient and noise resistant. We illustrate the effectiveness and robustness of our approach with some highly complex, large-scale, noisy biomedical geometries derived from medical images, including lung airways and blood vessels. We also present comparisons of our method with some existing methods. PMID:20628546

  19. Quantitative imaging biomarkers: the application of advanced image processing and analysis to clinical and preclinical decision making.

    PubMed

    Prescott, Jeffrey William

    2013-02-01

    The importance of medical imaging for clinical decision making has been steadily increasing over the last four decades. Recently, there has also been an emphasis on medical imaging for preclinical decision making, i.e., for use in pharamaceutical and medical device development. There is also a drive towards quantification of imaging findings by using quantitative imaging biomarkers, which can improve sensitivity, specificity, accuracy and reproducibility of imaged characteristics used for diagnostic and therapeutic decisions. An important component of the discovery, characterization, validation and application of quantitative imaging biomarkers is the extraction of information and meaning from images through image processing and subsequent analysis. However, many advanced image processing and analysis methods are not applied directly to questions of clinical interest, i.e., for diagnostic and therapeutic decision making, which is a consideration that should be closely linked to the development of such algorithms. This article is meant to address these concerns. First, quantitative imaging biomarkers are introduced by providing definitions and concepts. Then, potential applications of advanced image processing and analysis to areas of quantitative imaging biomarker research are described; specifically, research into osteoarthritis (OA), Alzheimer's disease (AD) and cancer is presented. Then, challenges in quantitative imaging biomarker research are discussed. Finally, a conceptual framework for integrating clinical and preclinical considerations into the development of quantitative imaging biomarkers and their computer-assisted methods of extraction is presented.

  20. Principal component analysis in construction of 3D human knee joint models using a statistical shape model method.

    PubMed

    Tsai, Tsung-Yuan; Li, Jing-Sheng; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Li, Guoan

    2015-01-01

    The statistical shape model (SSM) method that uses 2D images of the knee joint to predict the three-dimensional (3D) joint surface model has been reported in the literature. In this study, we constructed a SSM database using 152 human computed tomography (CT) knee joint models, including the femur, tibia and patella and analysed the characteristics of each principal component of the SSM. The surface models of two in vivo knees were predicted using the SSM and their 2D bi-plane fluoroscopic images. The predicted models were compared to their CT joint models. The differences between the predicted 3D knee joint surfaces and the CT image-based surfaces were 0.30 ± 0.81 mm, 0.34 ± 0.79 mm and 0.36 ± 0.59 mm for the femur, tibia and patella, respectively (average ± standard deviation). The computational time for each bone of the knee joint was within 30 s using a personal computer. The analysis of this study indicated that the SSM method could be a useful tool to construct 3D surface models of the knee with sub-millimeter accuracy in real time. Thus, it may have a broad application in computer-assisted knee surgeries that require 3D surface models of the knee.

  1. Using CamiTK for rapid prototyping of interactive computer assisted medical intervention applications.

    PubMed

    Promayon, Emmanuel; Fouard, Céline; Bailet, Mathieu; Deram, Aurélien; Fiard, Gaëlle; Hungr, Nikolai; Luboz, Vincent; Payan, Yohan; Sarrazin, Johan; Saubat, Nicolas; Selmi, Sonia Yuki; Voros, Sandrine; Cinquin, Philippe; Troccaz, Jocelyne

    2013-01-01

    Computer Assisted Medical Intervention (CAMI hereafter) is a complex multi-disciplinary field. CAMI research requires the collaboration of experts in several fields as diverse as medicine, computer science, mathematics, instrumentation, signal processing, mechanics, modeling, automatics, optics, etc. CamiTK is a modular framework that helps researchers and clinicians to collaborate together in order to prototype CAMI applications by regrouping the knowledge and expertise from each discipline. It is an open-source, cross-platform generic and modular tool written in C++ which can handle medical images, surgical navigation, biomedicals simulations and robot control. This paper presents the Computer Assisted Medical Intervention ToolKit (CamiTK) and how it is used in various applications in our research team.

  2. Morphometric computer-assisted image analysis of epithelial cells in different grades of oral squamous cell carcinoma.

    PubMed

    Ananjan, Chatterjee; Jyothi, Mahadesh; Laxmidevi, B L; Gopinathan, Pillai Arun; Nazir, Salroo Humaira; Pradeep, L

    2018-01-01

    Oral squamous cell carcinoma (OSCC) accounts 94% of all malignant lesions in the oral cavity. In the assessment of OSCC, nowadays the WHO grading system has been followed widely but due to its subjectivity, investigators applied the sophisticated technique of computer-assisted image analysis in the grading of carcinoma in larynx, lungs, esophagus, and cervix to make it more objective. Access, analyze, and compare the cellular area (CA); cytoplasmic area (Cyt A); nuclear area (NA); nuclear perimeter (NP); nuclear form factor (NF); and nuclear-cytoplasmic ratio (N/C) of the cells in different grades of OSCC. Fifty OSCC cases were obtained and stained with hematoxylin and eosin which were graded according to the WHO classification. The sections were subjected to morphometric analysis to analyze all the morphometric parameters in different grades of OSCC and subjected to one-way ANOVA statistical analysis. CA and Cyt A decreased from normal mucosa with dedifferentiation of OSCC. The NA and NP increased in carcinoma group when compared to normal mucosa but decreased with dedifferentiation of OSCC (P < 0.05). NF had no significance with normal mucosa and different grades of OSCC (P > 0.05), while N/C ratio increased from normal mucosa through increasing grades of OSCC, reaching the highest value in poorly differentiated squamous cell carcinoma (P < 0.05). Both cellular and nuclear variables provide a more accurate indication of tumor aggressiveness than any single parameter. Morphometric analysis can be a reliable tool to determine objectively the degree of malignancy at the invasive tumor front.

  3. Pedicle screw placement using image guided techniques.

    PubMed

    Merloz, P; Tonetti, J; Pittet, L; Coulomb, M; Lavalleé, S; Sautot, P

    1998-09-01

    Clinical evaluation of a computer assisted spine surgical system is presented. Eighty pedicle screws were inserted using computer assisted technology in thoracic and lumbar vertebrae for treatment of different types of disorders including fractures, spondylolisthesis, and scoliosis. Fifty-two patients with severe fractures, spondylolisthesis, or pseudoarthrosis of T10 to L5 were treated using a computer assisted technique on 1/2 the patients and performing the screw insertion manually for the other 1/2. At the same time, 28 pedicle screws were inserted in T12 to L4 vertebrae for scoliosis with the help of the computer assisted technique. Surgery was followed in all cases (66 vertebrae; 132 pedicle screws) by postoperative radiographs and computed tomographic examination, on which measurements of screw position relative to pedicle position could be done. For fractures, spondylolisthesis, or pseudarthrosis, comparison between the two groups showed that four screws in 52 (8%) vertebrae had incorrect placement with computer assisted technique whereas 22 screws in 52 (42%) vertebrae had incorrect placement with manual insertion. In patients with scoliosis, four screws in 28 (14%) vertebrae had incorrect placement. In all of the patients (132 pedicle screws) there were no neurologic complications. These results show that a computer assisted technique is much more accurate and safe than manual insertion.

  4. Covariance of lucky images: performance analysis

    NASA Astrophysics Data System (ADS)

    Cagigal, Manuel P.; Valle, Pedro J.; Cagigas, Miguel A.; Villó-Pérez, Isidro; Colodro-Conde, Carlos; Ginski, C.; Mugrauer, M.; Seeliger, M.

    2017-01-01

    The covariance of ground-based lucky images is a robust and easy-to-use algorithm that allows us to detect faint companions surrounding a host star. In this paper, we analyse the relevance of the number of processed frames, the frames' quality, the atmosphere conditions and the detection noise on the companion detectability. This analysis has been carried out using both experimental and computer-simulated imaging data. Although the technique allows us the detection of faint companions, the camera detection noise and the use of a limited number of frames reduce the minimum detectable companion intensity to around 1000 times fainter than that of the host star when placed at an angular distance corresponding to the few first Airy rings. The reachable contrast could be even larger when detecting companions with the assistance of an adaptive optics system.

  5. The Ilac-Project Supporting Ancient Coin Classification by Means of Image Analysis

    NASA Astrophysics Data System (ADS)

    Kavelar, A.; Zambanini, S.; Kampel, M.; Vondrovec, K.; Siegl, K.

    2013-07-01

    This paper presents the ILAC project, which aims at the development of an automated image-based classification system for ancient Roman Republican coins. The benefits of such a system are manifold: operating at the suture between computer vision and numismatics, ILAC can reduce the day-to-day workload of numismatists by assisting them in classification tasks and providing a preselection of suitable coin classes. This is especially helpful for large coin hoard findings comprising several thousands of coins. Furthermore, this system could be implemented in an online platform for hobby numismatists, allowing them to access background information about their coin collection by simply uploading a photo of obverse and reverse for the coin of interest. ILAC explores different computer vision techniques and their combinations for the use of image-based coin recognition. Some of these methods, such as image matching, use the entire coin image in the classification process, while symbol or legend recognition exploit certain characteristics of the coin imagery. An overview of the methods explored so far and the respective experiments is given as well as an outlook on the next steps of the project.

  6. Computer-assisted virtual autopsy using surgical navigation techniques.

    PubMed

    Ebert, Lars Christian; Ruder, Thomas D; Martinez, Rosa Maria; Flach, Patricia M; Schweitzer, Wolf; Thali, Michael J; Ampanozi, Garyfalia

    2015-01-01

    OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.

  7. Principal Component Analysis in Construction of 3D Human Knee Joint Models Using a Statistical Shape Model Method

    PubMed Central

    Tsai, Tsung-Yuan; Li, Jing-Sheng; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Li, Guoan

    2013-01-01

    The statistical shape model (SSM) method that uses 2D images of the knee joint to predict the 3D joint surface model has been reported in literature. In this study, we constructed a SSM database using 152 human CT knee joint models, including the femur, tibia and patella and analyzed the characteristics of each principal component of the SSM. The surface models of two in vivo knees were predicted using the SSM and their 2D bi-plane fluoroscopic images. The predicted models were compared to their CT joint models. The differences between the predicted 3D knee joint surfaces and the CT image-based surfaces were 0.30 ± 0.81 mm, 0.34 ± 0.79 mm and 0.36 ± 0.59 mm for the femur, tibia and patella, respectively (average ± standard deviation). The computational time for each bone of the knee joint was within 30 seconds using a personal computer. The analysis of this study indicated that the SSM method could be a useful tool to construct 3D surface models of the knee with sub-millimeter accuracy in real time. Thus it may have a broad application in computer assisted knee surgeries that require 3D surface models of the knee. PMID:24156375

  8. Benchmark datasets for 3D MALDI- and DESI-imaging mass spectrometry.

    PubMed

    Oetjen, Janina; Veselkov, Kirill; Watrous, Jeramie; McKenzie, James S; Becker, Michael; Hauberg-Lotte, Lena; Kobarg, Jan Hendrik; Strittmatter, Nicole; Mróz, Anna K; Hoffmann, Franziska; Trede, Dennis; Palmer, Andrew; Schiffler, Stefan; Steinhorst, Klaus; Aichler, Michaela; Goldin, Robert; Guntinas-Lichius, Orlando; von Eggeling, Ferdinand; Thiele, Herbert; Maedler, Kathrin; Walch, Axel; Maass, Peter; Dorrestein, Pieter C; Takats, Zoltan; Alexandrov, Theodore

    2015-01-01

    Three-dimensional (3D) imaging mass spectrometry (MS) is an analytical chemistry technique for the 3D molecular analysis of a tissue specimen, entire organ, or microbial colonies on an agar plate. 3D-imaging MS has unique advantages over existing 3D imaging techniques, offers novel perspectives for understanding the spatial organization of biological processes, and has growing potential to be introduced into routine use in both biology and medicine. Owing to the sheer quantity of data generated, the visualization, analysis, and interpretation of 3D imaging MS data remain a significant challenge. Bioinformatics research in this field is hampered by the lack of publicly available benchmark datasets needed to evaluate and compare algorithms. High-quality 3D imaging MS datasets from different biological systems at several labs were acquired, supplied with overview images and scripts demonstrating how to read them, and deposited into MetaboLights, an open repository for metabolomics data. 3D imaging MS data were collected from five samples using two types of 3D imaging MS. 3D matrix-assisted laser desorption/ionization imaging (MALDI) MS data were collected from murine pancreas, murine kidney, human oral squamous cell carcinoma, and interacting microbial colonies cultured in Petri dishes. 3D desorption electrospray ionization (DESI) imaging MS data were collected from a human colorectal adenocarcinoma. With the aim to stimulate computational research in the field of computational 3D imaging MS, selected high-quality 3D imaging MS datasets are provided that could be used by algorithm developers as benchmark datasets.

  9. Big Data and Deep data in scanning and electron microscopies: functionality from multidimensional data sets

    DOE PAGES

    Belianinov, Alex; Vasudevan, Rama K; Strelcov, Evgheni; ...

    2015-05-13

    The development of electron, and scanning probe microscopies in the second half of the twentieth century have produced spectacular images of internal structure and composition of matter with, at nanometer, molecular, and atomic resolution. Largely, this progress was enabled by computer-assisted methods of microscope operation, data acquisition and analysis. The progress in imaging technologies in the beginning of the twenty first century has opened the proverbial floodgates of high-veracity information on structure and functionality. High resolution imaging now allows information on atomic positions with picometer precision, allowing for quantitative measurements of individual bond length and angles. Functional imaging often leadsmore » to multidimensional data sets containing partial or full information on properties of interest, acquired as a function of multiple parameters (time, temperature, or other external stimuli). Here, we review several recent applications of the big and deep data analysis methods to visualize, compress, and translate this data into physically and chemically relevant information from imaging data.« less

  10. Big Data and Deep data in scanning and electron microscopies: functionality from multidimensional data sets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belianinov, Alex; Vasudevan, Rama K; Strelcov, Evgheni

    The development of electron, and scanning probe microscopies in the second half of the twentieth century have produced spectacular images of internal structure and composition of matter with, at nanometer, molecular, and atomic resolution. Largely, this progress was enabled by computer-assisted methods of microscope operation, data acquisition and analysis. The progress in imaging technologies in the beginning of the twenty first century has opened the proverbial floodgates of high-veracity information on structure and functionality. High resolution imaging now allows information on atomic positions with picometer precision, allowing for quantitative measurements of individual bond length and angles. Functional imaging often leadsmore » to multidimensional data sets containing partial or full information on properties of interest, acquired as a function of multiple parameters (time, temperature, or other external stimuli). Here, we review several recent applications of the big and deep data analysis methods to visualize, compress, and translate this data into physically and chemically relevant information from imaging data.« less

  11. Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer.

    PubMed

    Akiba, Tadashi; Marushima, Hideki; Harada, Junta; Kobayashi, Susumu; Morikawa, Toshiaki

    2009-01-01

    Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. 3D-MDCT imaging is useful for preoperatively understanding the individual thoracic anatomy in lung cancer surgery. This modality can therefore contribute to safer anatomical pulmonary operations, especially in VATS.

  12. Local Orthogonal Cutting Method for Computing Medial Curves and Its Biomedical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiao, Xiangmin; Einstein, Daniel R.; Dyedov, Volodymyr

    2010-03-24

    Medial curves have a wide range of applications in geometric modeling and analysis (such as shape matching) and biomedical engineering (such as morphometry and computer assisted surgery). The computation of medial curves poses significant challenges, both in terms of theoretical analysis and practical efficiency and reliability. In this paper, we propose a definition and analysis of medial curves and also describe an efficient and robust method for computing medial curves. Our approach is based on three key concepts: a local orthogonal decomposition of objects into substructures, a differential geometry concept called the interior center of curvature (ICC), and integrated stabilitymore » and consistency tests. These concepts lend themselves to robust numerical techniques including eigenvalue analysis, weighted least squares approximations, and numerical minimization, resulting in an algorithm that is efficient and noise resistant. We illustrate the effectiveness and robustness of our approach with some highly complex, large-scale, noisy biomedical geometries derived from medical images, including lung airways and blood vessels. We also present comparisons of our method with some existing methods.« less

  13. Identification of high versus lower risk clinical subgroups in a group of adult patients with supratentorial anaplastic astrocytomas.

    PubMed

    Decaestecker, C; Salmon, I; Camby, I; Dewitte, O; Pasteels, J L; Brotchi, J; Van Ham, P; Kiss, R

    1995-05-01

    The present work investigates whether computer-assisted techniques can contribute any significant information to the characterization of astrocytic tumor aggressiveness. Two complementary computer-assisted methods were used. The first method made use of the digital image analysis of Feulgen-stained nuclei, making it possible to compute 15 morphonuclear and 8 nuclear DNA content-related (ploidy level) parameters. The second method enabled the most discriminatory parameters to be determined. This second method is the Decision Tree technique, which forms part of the Supervised Learning Algorithms. These two techniques were applied to a series of 250 supratentorial astrocytic tumors of the adult. This series included 39 low-grade (astrocytomas, AST) and 211 high-grade (47 anaplastic astrocytomas, ANA, and 164 glioblastomas, GBM) astrocytic tumors. The results show that some AST, ANA and GBM did not fit within simple logical rules. These "complex" cases were labeled NC-AST, NC-ANA and NC-GBM because they were "non-classical" (NC) with respect to their cytological features. An analysis of survival data revealed that the patients with NC-GBM had the same survival period as patients with GBM. In sharp contrast, patients with ANA survived significantly longer than patients with NC-ANA. In fact, the patients with ANA had the same survival period as patients who died from AST, while the patients with NC-ANA had a survival period similar to those with GBM. All these data show that the computer-assisted techniques used in this study can actually provide the pathologist with significant information on the characterization of astrocytic tumor aggressiveness.

  14. Preliminary development of a workstation for craniomaxillofacial surgical procedures: introducing a computer-assisted planning and execution system.

    PubMed

    Gordon, Chad R; Murphy, Ryan J; Coon, Devin; Basafa, Ehsan; Otake, Yoshito; Al Rakan, Mohammed; Rada, Erin; Susarla, Srinivas; Susarla, Sriniras; Swanson, Edward; Fishman, Elliot; Santiago, Gabriel; Brandacher, Gerald; Liacouras, Peter; Grant, Gerald; Armand, Mehran

    2014-01-01

    Facial transplantation represents one of the most complicated scenarios in craniofacial surgery because of skeletal, aesthetic, and dental discrepancies between donor and recipient. However, standard off-the-shelf vendor computer-assisted surgery systems may not provide custom features to mitigate the increased complexity of this particular procedure. We propose to develop a computer-assisted surgery solution customized for preoperative planning, intraoperative navigation including cutting guides, and dynamic, instantaneous feedback of cephalometric measurements/angles as needed for facial transplantation and other related craniomaxillofacial procedures. We developed the Computer-Assisted Planning and Execution (CAPE) workstation to assist with planning and execution of facial transplantation. Preoperative maxillofacial computed tomography (CT) scans were obtained on 4 size-mismatched miniature swine encompassing 2 live face-jaw-teeth transplants. The system was tested in a laboratory setting using plastic models of mismatched swine, after which the system was used in 2 live swine transplants. Postoperative CT imaging was obtained and compared with the preoperative plan and intraoperative measures from the CAPE workstation for both transplants. Plastic model tests familiarized the team with the CAPE workstation and identified several defects in the workflow. Live swine surgeries demonstrated utility of the CAPE system in the operating room, showing submillimeter registration error of 0.6 ± 0.24 mm and promising qualitative comparisons between intraoperative data and postoperative CT imaging. The initial development of the CAPE workstation demonstrated that integration of computer planning and intraoperative navigation for facial transplantation are possible with submillimeter accuracy. This approach can potentially improve preoperative planning, allowing ideal donor-recipient matching despite significant size mismatch, and accurate surgical execution for numerous types of craniofacial and orthognathic surgical procedures.

  15. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing.

    PubMed

    Oshiro, Yukio; Ohkohchi, Nobuhiro

    2017-06-01

    To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.

  16. Computer-assisted surgery planning in children with complex liver tumors identifies variability of the classical Couinaud classification.

    PubMed

    Warmann, Steven W; Schenk, Andrea; Schaefer, Juergen F; Ebinger, Martin; Blumenstock, Gunnar; Tsiflikas, Ilias; Fuchs, Joerg

    2016-11-01

    In complex malignant pediatric liver tumors there is an ongoing discussion regarding surgical strategy; for example, primary organ transplantation versus extended resection in hepatoblastoma involving 3 or 4 sectors of the liver. We evaluated the possible role of computer-assisted surgery planning in children with complex hepatic tumors. Between May 2004 and March 2016, 24 Children with complex liver tumors underwent standard multislice helical CT scan or MRI scan at our institution. Imaging data were processed using the software assistant LiverAnalyzer (Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany). Results were provided as Portable Document Format (PDF) with embedded interactive 3-dimensional surface mesh models. Median age of patients was 33months. Diagnoses were hepatoblastoma (n=14), sarcoma (n=3), benign parenchyma alteration (n=2), as well as hepatocellular carcinoma, rhabdoid tumor, focal nodular hyperplasia, hemangioendothelioma, or multiple hepatic metastases of a pancreas carcinoma (each n=1). Volumetry of liver segments identified remarkable variations and substantial aberrances from the Couinaud classification. Computer-assisted surgery planning was used to determine surgical strategies in 20/24 children; this was especially relevant in tumors affecting 3 or 4 liver sectors. Primary liver transplantation could be avoided in 12 of 14 hepaoblastoma patients who theoretically were candidates for this approach. Computer-assisted surgery planning substantially contributed to the decision for surgical strategies in children with complex hepatic tumors. This tool possibly allows determination of specific surgical procedures such as extended surgical resection instead of primary transplantation in certain conditions. Copyright © 2016. Published by Elsevier Inc.

  17. Computer-assisted neurosurgical navigational system for transsphenoidal surgery--technical note.

    PubMed

    Onizuka, M; Tokunaga, Y; Shibayama, A; Miyazaki, H

    2001-11-01

    Transsphenoidal surgery carries the risk of carotid artery injury even for very experienced neurosurgeons. The computer-assisted neurosurgical (CANS) navigational system was used to obtain more precise guidance, based on the axial and coronal images during the transsphenoidal approach for nine pituitary adenomas. The CANS navigator consists of a three-dimensional digitizer, a computer, and a graphic unit, which utilizes electromagnetic coupling technology to detect the spatial position of a suction tube attached to a magnetic sensor. Preoperatively, the magnetic resonance images are transferred and stored in the computer and the tip of the suction tube is shown on a real-time basis superimposed on the preoperative images. The CANS navigation system correctly displayed the surgical orientation and provided localization in all nine patients. No intraoperative complications were associated with the use of this system. However, outflow of cerebrospinal fluid during tumor removal may affect the accuracy, so the position of the probe when the tumor is removed must be accurately determined. The CANS navigator enables precise localization of the suction tube during the transsphenoidal approach and allows safer and less-invasive surgery.

  18. Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, S.T.C.

    The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound,more » electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.« less

  19. An advanced design of non-radioactive image capturing and management system for applications in non-invasive skin disorder diagnosis

    NASA Astrophysics Data System (ADS)

    Liu, Carol Y. B.; Luk, David C. K.; Zhou, Kany S. Y.; So, Bryan M. K.; Louie, Derek C. H.

    2015-03-01

    Due to the increasing incidences of malignant melanoma, there is a rising demand for assistive technologies for its early diagnosis and improving the survival rate. The commonly used visual screening method is with limited accuracy as the early phase of melanoma shares many clinical features with an atypical nevus, while conventional dermoscopes are not user-friendly in terms of setup time and operations. Therefore, the development of an intelligent and handy system to assist the accurate screening and long-term monitoring of melanocytic skin lesions is crucial for early diagnosis and prevention of melanoma. In this paper, an advanced design of non-invasive and non-radioactive dermoscopy system was reported. Computer-aided simulations were conducted for optimizing the optical design and uniform illumination distribution. Functional prototype and the software system were further developed, which could enable image capturing at 10x amplified and general modes, convenient data transmission, analysis of dermoscopic features (e.g., asymmetry, border irregularity, color, diameter and dermoscopic structure) for assisting the early detection of melanoma, extract patient information (e.g. code, lesion location) and integrate with dermoscopic images, thus further support long term monitoring of diagnostic analysis results. A clinical trial study was further conducted on 185 Chinese children (0-18 years old). The results showed that for all subjects, skin conditions diagnosed based on the developed system accurately confirmed the diagnoses by conventional clinical procedures. Besides, clinical analysis on dermoscopic features and a potential standard approach by the developed system to support identifying specific melanocytic patterns for dermoscopic examination in Chinese children were also reported.

  20. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    PubMed

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, p<0.001). The five- and 10-year survival rates were 97.1% and 89.6%, respectively. No difference was detected in nine-year survival rates (p=0.369) between the two groups, although the clinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A Multi-center Milestone Study of Clinical Vertebral CT Segmentation

    PubMed Central

    Yao, Jianhua; Burns, Joseph E.; Forsberg, Daniel; Seitel, Alexander; Rasoulian, Abtin; Abolmaesumi, Purang; Hammernik, Kerstin; Urschler, Martin; Ibragimov, Bulat; Korez, Robert; Vrtovec, Tomaž; Castro-Mateos, Isaac; Pozo, Jose M.; Frangi, Alejandro F.; Summers, Ronald M.; Li, Shuo

    2017-01-01

    A multiple center milestone study of clinical vertebra segmentation is presented in this paper. Vertebra segmentation is a fundamental step for spinal image analysis and intervention. The first half of the study was conducted in the spine segmentation challenge in 2014 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) Workshop on Computational Spine Imaging (CSI 2014). The objective was to evaluate the performance of several state-of-the-art vertebra segmentation algorithms on computed tomography (CT) scans using ten training and five testing dataset, all healthy cases; the second half of the study was conducted after the challenge, where additional 5 abnormal cases are used for testing to evaluate the performance under abnormal cases. Dice coefficients and absolute surface distances were used as evaluation metrics. Segmentation of each vertebra as a single geometric unit, as well as separate segmentation of vertebra substructures, was evaluated. Five teams participated in the comparative study. The top performers in the study achieved Dice coefficient of 0.93 in the upper thoracic, 0.95 in the lower thoracic and 0.96 in the lumbar spine for healthy cases, and 0.88 in the upper thoracic, 0.89 in the lower thoracic and 0.92 in the lumbar spine for osteoporotic and fractured cases. The strengths and weaknesses of each method as well as future suggestion for improvement are discussed. This is the first multi-center comparative study for vertebra segmentation methods, which will provide an up-to-date performance milestone for the fast growing spinal image analysis and intervention. PMID:26878138

  2. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    PubMed

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  3. Effect of starvation and refeeding on the hepatopancreas of whiteleg shrimp Penaeus vannamei (Boone) using computer-assisted image analysis.

    PubMed

    Cervellione, F; McGurk, C; Berger Eriksen, T; Van den Broeck, W

    2017-11-01

    Under normal farming conditions, shrimp can experience starvation periods attributable to disease outbreaks or adverse environmental conditions. Starvation leads to significant morphological changes in the hepatopancreas (HP), being the main organ for absorption and storage of nutrients. In the literature, limited research has described the effect on the HP of periods of starvation followed by refeeding and none in whiteleg shrimp (Penaeus vannamei) using computer-assisted image analysis (CAIA). This study describes the effect of starvation and starvation followed by refeeding on the HP of whiteleg shrimp using CAIA. Visiopharm ® software was used to quantify the following morphological parameters, measured as ratio to the total tissue area (TLA): total lumen area (TLA:TTA), haemocytic infiltration area in the intertubular spaces (HIA:TTA), B-cell vacuole area (VBA:TTA), lipid droplet area within R cells (LDA:TTA) and F-cell area (FCA:TTA). Significant changes were measured for HIA:TTA and LDA:TTA during starvation (increase in HIA:TTA associated with decrease in LDA:TTA) and starvation followed by refeeding (decrease in HIA:TTA associated with increase in LDA:TTA). In the future, HIA:TTA and LDA:TTA have the potential to be used in a pre-emptive manner to monitor the health of the HP, facilitate early diagnosis of diseases and study the pathophysiology of the organ. © 2017 John Wiley & Sons Ltd.

  4. A framework for the recognition of high-level surgical tasks from video images for cataract surgeries

    PubMed Central

    Lalys, Florent; Riffaud, Laurent; Bouget, David; Jannin, Pierre

    2012-01-01

    The need for a better integration of the new generation of Computer-Assisted-Surgical (CAS) systems has been recently emphasized. One necessity to achieve this objective is to retrieve data from the Operating Room (OR) with different sensors, then to derive models from these data. Recently, the use of videos from cameras in the OR has demonstrated its efficiency. In this paper, we propose a framework to assist in the development of systems for the automatic recognition of high level surgical tasks using microscope videos analysis. We validated its use on cataract procedures. The idea is to combine state-of-the-art computer vision techniques with time series analysis. The first step of the framework consisted in the definition of several visual cues for extracting semantic information, therefore characterizing each frame of the video. Five different pieces of image-based classifiers were therefore implemented. A step of pupil segmentation was also applied for dedicated visual cue detection. Time series classification algorithms were then applied to model time-varying data. Dynamic Time Warping (DTW) and Hidden Markov Models (HMM) were tested. This association combined the advantages of all methods for better understanding of the problem. The framework was finally validated through various studies. Six binary visual cues were chosen along with 12 phases to detect, obtaining accuracies of 94%. PMID:22203700

  5. Use of technology in children’s dietary assessment

    PubMed Central

    Boushey, CJ; Kerr, DA; Wright, J; Lutes, KD; Ebert, DS; Delp, EJ

    2010-01-01

    Background Information on dietary intake provides some of the most valuable insights for mounting intervention programmes for the prevention of chronic diseases. With the growing concern about adolescent overweight, the need to accurately measure diet becomes imperative. Assessment among adolescents is problematic as this group has irregular eating patterns and they have less enthusiasm for recording food intake. Subjects/Methods We used qualitative and quantitative techniques among adolescents to assess their preferences for dietary assessment methods. Results Dietary assessment methods using technology, for example, a personal digital assistant (PDA) or a disposable camera, were preferred over the pen and paper food record. Conclusions There was a strong preference for using methods that incorporate technology such as capturing images of food. This suggests that for adolescents, dietary methods that incorporate technology may improve cooperation and accuracy. Current computing technology includes higher resolution images, improved memory capacity and faster processors that allow small mobile devices to process information not previously possible. Our goal is to develop, implement and evaluate a mobile device (for example, PDA, mobile phone) food record that will translate to an accurate account of daily food and nutrient intake among adolescents. This mobile computing device will include digital images, a nutrient database and image analysis for identification and quantification of food consumption. Mobile computing devices provide a unique vehicle for collecting dietary information that reduces the burden on record keepers. Images of food can be marked with a variety of input methods that link the item for image processing and analysis to estimate the amount of food. Images before and after the foods are eaten can estimate the amount of food consumed. The initial stages and potential of this project will be described. PMID:19190645

  6. Use of technology in children's dietary assessment.

    PubMed

    Boushey, C J; Kerr, D A; Wright, J; Lutes, K D; Ebert, D S; Delp, E J

    2009-02-01

    Information on dietary intake provides some of the most valuable insights for mounting intervention programmes for the prevention of chronic diseases. With the growing concern about adolescent overweight, the need to accurately measure diet becomes imperative. Assessment among adolescents is problematic as this group has irregular eating patterns and they have less enthusiasm for recording food intake. We used qualitative and quantitative techniques among adolescents to assess their preferences for dietary assessment methods. Dietary assessment methods using technology, for example, a personal digital assistant (PDA) or a disposable camera, were preferred over the pen and paper food record. There was a strong preference for using methods that incorporate technology such as capturing images of food. This suggests that for adolescents, dietary methods that incorporate technology may improve cooperation and accuracy. Current computing technology includes higher resolution images, improved memory capacity and faster processors that allow small mobile devices to process information not previously possible. Our goal is to develop, implement and evaluate a mobile device (for example, PDA, mobile phone) food record that will translate to an accurate account of daily food and nutrient intake among adolescents. This mobile computing device will include digital images, a nutrient database and image analysis for identification and quantification of food consumption. Mobile computing devices provide a unique vehicle for collecting dietary information that reduces the burden on record keepers. Images of food can be marked with a variety of input methods that link the item for image processing and analysis to estimate the amount of food. Images before and after the foods are eaten can estimate the amount of food consumed. The initial stages and potential of this project will be described.

  7. Digital mammography, cancer screening: Factors important for image compression

    NASA Technical Reports Server (NTRS)

    Clarke, Laurence P.; Blaine, G. James; Doi, Kunio; Yaffe, Martin J.; Shtern, Faina; Brown, G. Stephen; Winfield, Daniel L.; Kallergi, Maria

    1993-01-01

    The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

  8. Metric Learning to Enhance Hyperspectral Image Segmentation

    NASA Technical Reports Server (NTRS)

    Thompson, David R.; Castano, Rebecca; Bue, Brian; Gilmore, Martha S.

    2013-01-01

    Unsupervised hyperspectral image segmentation can reveal spatial trends that show the physical structure of the scene to an analyst. They highlight borders and reveal areas of homogeneity and change. Segmentations are independently helpful for object recognition, and assist with automated production of symbolic maps. Additionally, a good segmentation can dramatically reduce the number of effective spectra in an image, enabling analyses that would otherwise be computationally prohibitive. Specifically, using an over-segmentation of the image instead of individual pixels can reduce noise and potentially improve the results of statistical post-analysis. In this innovation, a metric learning approach is presented to improve the performance of unsupervised hyperspectral image segmentation. The prototype demonstrations attempt a superpixel segmentation in which the image is conservatively over-segmented; that is, the single surface features may be split into multiple segments, but each individual segment, or superpixel, is ensured to have homogenous mineralogy.

  9. A comparative approach to computer aided design model of a dog femur.

    PubMed

    Turamanlar, O; Verim, O; Karabulut, A

    2016-01-01

    Computer assisted technologies offer new opportunities in medical imaging and rapid prototyping in biomechanical engineering. Three dimensional (3D) modelling of soft tissues and bones are becoming more important. The accuracy of the analysis in modelling processes depends on the outline of the tissues derived from medical images. The aim of this study is the evaluation of the accuracy of 3D models of a dog femur derived from computed tomography data by using point cloud method and boundary line method on several modelling software. Solidworks, Rapidform and 3DSMax software were used to create 3D models and outcomes were evaluated statistically. The most accurate 3D prototype of the dog femur was created with stereolithography method using rapid prototype device. Furthermore, the linearity of the volumes of models was investigated between software and the constructed models. The difference between the software and real models manifests the sensitivity of the software and the devices used in this manner.

  10. Computer-aided analysis for the Mechanics of Granular Materials (MGM) experiment, part 2

    NASA Technical Reports Server (NTRS)

    Parker, Joey K.

    1987-01-01

    Computer vision based analysis for the MGM experiment is continued and expanded into new areas. Volumetric strains of granular material triaxial test specimens have been measured from digitized images. A computer-assisted procedure is used to identify the edges of the specimen, and the edges are used in a 3-D model to estimate specimen volume. The results of this technique compare favorably to conventional measurements. A simplified model of the magnification caused by diffraction of light within the water of the test apparatus was also developed. This model yields good results when the distance between the camera and the test specimen is large compared to the specimen height. An algorithm for a more accurate 3-D magnification correction is also presented. The use of composite and RGB (red-green-blue) color cameras is discussed and potentially significant benefits from using an RGB camera are presented.

  11. Computer-Assisted Orthopedic Surgery: Current State and Future Perspective

    PubMed Central

    Zheng, Guoyan; Nolte, Lutz P.

    2015-01-01

    Introduced about two decades ago, computer-assisted orthopedic surgery (CAOS) has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined. PMID:26779486

  12. Intraoperative 3-Dimensional Computed Tomography and Navigation in Foot and Ankle Surgery.

    PubMed

    Chowdhary, Ashwin; Drittenbass, Lisca; Dubois-Ferrière, Victor; Stern, Richard; Assal, Mathieu

    2016-09-01

    Computer-assisted orthopedic surgery has developed dramatically during the past 2 decades. This article describes the use of intraoperative 3-dimensional computed tomography and navigation in foot and ankle surgery. Traditional imaging based on serial radiography or C-arm-based fluoroscopy does not provide simultaneous real-time 3-dimensional imaging, and thus leads to suboptimal visualization and guidance. Three-dimensional computed tomography allows for accurate intraoperative visualization of the position of bones and/or navigation implants. Such imaging and navigation helps to further reduce intraoperative complications, leads to improved surgical outcomes, and may become the gold standard in foot and ankle surgery. [Orthopedics.2016; 39(5):e1005-e1010.]. Copyright 2016, SLACK Incorporated.

  13. Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA

    PubMed Central

    Gallas, Brandon D.; Chan, Heang-Ping; D’Orsi, Carl J.; Dodd, Lori E.; Giger, Maryellen L.; Gur, David; Krupinski, Elizabeth A.; Metz, Charles E.; Myers, Kyle J.; Obuchowski, Nancy A.; Sahiner, Berkman; Toledano, Alicia Y.; Zuley, Margarita L.

    2017-01-01

    This report summarizes the Joint FDA-MIPS Workshop on Methods for the Evaluation of Imaging and Computer-Assist Devices. The purpose of the workshop was to gather information on the current state of the science and facilitate consensus development on statistical methods and study designs for the evaluation of imaging devices to support US Food and Drug Administration submissions. Additionally, participants expected to identify gaps in knowledge and unmet needs that should be addressed in future research. This summary is intended to document the topics that were discussed at the meeting and disseminate the lessons that have been learned through past studies of imaging and computer-aided detection and diagnosis device performance. PMID:22306064

  14. Computer-Assisted Analysis of Spontaneous Speech: Quantification of Basic Parameters in Aphasic and Unimpaired Language

    ERIC Educational Resources Information Center

    Hussmann, Katja; Grande, Marion; Meffert, Elisabeth; Christoph, Swetlana; Piefke, Martina; Willmes, Klaus; Huber, Walter

    2012-01-01

    Although generally accepted as an important part of aphasia assessment, detailed analysis of spontaneous speech is rarely carried out in clinical practice mostly due to time limitations. The Aachener Sprachanalyse (ASPA; Aachen Speech Analysis) is a computer-assisted method for the quantitative analysis of German spontaneous speech that allows for…

  15. Free software for performing physical analysis of systems for digital radiography and mammography.

    PubMed

    Donini, Bruno; Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco

    2014-05-01

    In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online (www.medphys.it/downloads.htm). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

  16. The Physics of Physical Examinations.

    ERIC Educational Resources Information Center

    Patterson, James D.

    1989-01-01

    Discussed are several topics on medical imaging including x-rays and Computer Assisted Tomography (CAT) scans, magnetic resonance imaging, fiber optics endoscopy, nuclear medicine and bone scans, positron-emission tomography, and ultrasound. The concepts of radiation dosage, electrocardiograms, and laser therapy are included. (YP)

  17. Computer assisted optical biopsy for colorectal polyps

    NASA Astrophysics Data System (ADS)

    Navarro-Avila, Fernando J.; Saint-Hill-Febles, Yadira; Renner, Janis; Klare, Peter; von Delius, Stefan; Navab, Nassir; Mateus, Diana

    2017-03-01

    We propose a method for computer-assisted optical biopsy for colorectal polyps, with the final goal of assisting the medical expert during the colonoscopy. In particular, we target the problem of automatic classification of polyp images in two classes: adenomatous vs non-adenoma. Our approach is based on recent advancements in convolutional neural networks (CNN) for image representation. In the paper, we describe and compare four different methodologies to address the binary classification task: a baseline with classical features and a Random Forest classifier, two methods based on features obtained from a pre-trained network, and finally, the end-to-end training of a CNN. With the pre-trained network, we show the feasibility of transferring a feature extraction mechanism trained on millions of natural images, to the task of classifying adenomatous polyps. We then demonstrate further performance improvements when training the CNN for our specific classification task. In our study, 776 polyp images were acquired and histologically analyzed after polyp resection. We report a performance increase of the CNN-based approaches with respect to both, the conventional engineered features and to a state-of-the-art method based on videos and 3D shape features.

  18. Segmentation of breast ultrasound images based on active contours using neutrosophic theory.

    PubMed

    Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A

    2018-04-01

    Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.

  19. Image analysis and modeling in medical image computing. Recent developments and advances.

    PubMed

    Handels, H; Deserno, T M; Meinzer, H-P; Tolxdorff, T

    2012-01-01

    Medical image computing is of growing importance in medical diagnostics and image-guided therapy. Nowadays, image analysis systems integrating advanced image computing methods are used in practice e.g. to extract quantitative image parameters or to support the surgeon during a navigated intervention. However, the grade of automation, accuracy, reproducibility and robustness of medical image computing methods has to be increased to meet the requirements in clinical routine. In the focus theme, recent developments and advances in the field of modeling and model-based image analysis are described. The introduction of models in the image analysis process enables improvements of image analysis algorithms in terms of automation, accuracy, reproducibility and robustness. Furthermore, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients. Selected contributions are assembled to present latest advances in the field. The authors were invited to present their recent work and results based on their outstanding contributions to the Conference on Medical Image Computing BVM 2011 held at the University of Lübeck, Germany. All manuscripts had to pass a comprehensive peer review. Modeling approaches and model-based image analysis methods showing new trends and perspectives in model-based medical image computing are described. Complex models are used in different medical applications and medical images like radiographic images, dual-energy CT images, MR images, diffusion tensor images as well as microscopic images are analyzed. The applications emphasize the high potential and the wide application range of these methods. The use of model-based image analysis methods can improve segmentation quality as well as the accuracy and reproducibility of quantitative image analysis. Furthermore, image-based models enable new insights and can lead to a deeper understanding of complex dynamic mechanisms in the human body. Hence, model-based image computing methods are important tools to improve medical diagnostics and patient treatment in future.

  20. Effectiveness of Computer-Assisted Mathematics Education (CAME) over Academic Achievement: A Meta-Analysis Study

    ERIC Educational Resources Information Center

    Demir, Seda; Basol, Gülsah

    2014-01-01

    The aim of the current study is to determine the overall effects of Computer-Assisted Mathematics Education (CAME) on academic achievement. After an extensive review of the literature, studies using Turkish samples and observing the effects of Computer-Assisted Education (CAE) on mathematics achievement were examined. As a result of this…

  1. Microscopic medical image classification framework via deep learning and shearlet transform.

    PubMed

    Rezaeilouyeh, Hadi; Mollahosseini, Ali; Mahoor, Mohammad H

    2016-10-01

    Cancer is the second leading cause of death in US after cardiovascular disease. Image-based computer-aided diagnosis can assist physicians to efficiently diagnose cancers in early stages. Existing computer-aided algorithms use hand-crafted features such as wavelet coefficients, co-occurrence matrix features, and recently, histogram of shearlet coefficients for classification of cancerous tissues and cells in images. These hand-crafted features often lack generalizability since every cancerous tissue and cell has a specific texture, structure, and shape. An alternative approach is to use convolutional neural networks (CNNs) to learn the most appropriate feature abstractions directly from the data and handle the limitations of hand-crafted features. A framework for breast cancer detection and prostate Gleason grading using CNN trained on images along with the magnitude and phase of shearlet coefficients is presented. Particularly, we apply shearlet transform on images and extract the magnitude and phase of shearlet coefficients. Then we feed shearlet features along with the original images to our CNN consisting of multiple layers of convolution, max pooling, and fully connected layers. Our experiments show that using the magnitude and phase of shearlet coefficients as extra information to the network can improve the accuracy of detection and generalize better compared to the state-of-the-art methods that rely on hand-crafted features. This study expands the application of deep neural networks into the field of medical image analysis, which is a difficult domain considering the limited medical data available for such analysis.

  2. An automated normative-based fluorodeoxyglucose positron emission tomography image-analysis procedure to aid Alzheimer disease diagnosis using statistical parametric mapping and interactive image display

    NASA Astrophysics Data System (ADS)

    Chen, Kewei; Ge, Xiaolin; Yao, Li; Bandy, Dan; Alexander, Gene E.; Prouty, Anita; Burns, Christine; Zhao, Xiaojie; Wen, Xiaotong; Korn, Ronald; Lawson, Michael; Reiman, Eric M.

    2006-03-01

    Having approved fluorodeoxyglucose positron emission tomography (FDG PET) for the diagnosis of Alzheimer's disease (AD) in some patients, the Centers for Medicare and Medicaid Services suggested the need to develop and test analysis techniques to optimize diagnostic accuracy. We developed an automated computer package comparing an individual's FDG PET image to those of a group of normal volunteers. The normal control group includes FDG-PET images from 82 cognitively normal subjects, 61.89+/-5.67 years of age, who were characterized demographically, clinically, neuropsychologically, and by their apolipoprotein E genotype (known to be associated with a differential risk for AD). In addition, AD-affected brain regions functionally defined as based on a previous study (Alexander, et al, Am J Psychiatr, 2002) were also incorporated. Our computer package permits the user to optionally select control subjects, matching the individual patient for gender, age, and educational level. It is fully streamlined to require minimal user intervention. With one mouse click, the program runs automatically, normalizing the individual patient image, setting up a design matrix for comparing the single subject to a group of normal controls, performing the statistics, calculating the glucose reduction overlap index of the patient with the AD-affected brain regions, and displaying the findings in reference to the AD regions. In conclusion, the package automatically contrasts a single patient to a normal subject database using sound statistical procedures. With further validation, this computer package could be a valuable tool to assist physicians in decision making and communicating findings with patients and patient families.

  3. A new method for computer-assisted detection, definition and differentiation of the urinary calculi.

    PubMed

    Yildirim, Duzgun; Ozturk, Ovunc; Tutar, Onur; Nurili, Fuad; Bozkurt, Halil; Kayadibi, Huseyin; Karaarslan, Ercan; Bakan, Selim

    2014-09-01

    Urinary stones are common and can be diagnosed with computed tomography (CT) easily. In this study, we aimed to specify the opacity characteristics of various types of calcified foci that develop through the urinary system by using an image analysis program. With this method, we try to differentiate the calculi from the non-calculous opacities and also we aimed to present how to identify the characteristic features of renal and ureteral calcules. We obtained the CT studies of the subjects (n = 48, mean age = 41 years) by using a dual source CT imaging system. We grouped the calculi detected in the dual-energy CT sections as renal (n = 40) or ureteric (n = 45) based on their locations. Other radio-opaque structures that were identified outside but within close proximity of the urinary tract were recorded as calculi "mimickers". We used ImageJ program for morphological analysis. All the acquired data were analyzed statistically. According to thorough morphological parameters, there were statistically significant differences in the angle and Feret angle values between calculi and mimickers (p < 0.001). Multivariate logistical regression analysis showed that Minor Axis and Feret angle parameters can be used to distinguish between ureteric (p = 0.003) and kidney (p = 0.001) stones. Computer-based morphologic parameters can be used simply to differentiate between calcular and noncalcular densities on CT and also between renal and ureteric stones.

  4. Computer-aided diagnosis and artificial intelligence in clinical imaging.

    PubMed

    Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio

    2011-11-01

    Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and communication systems and will become a standard of care for diagnostic examinations in daily clinical work. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. [Virtual reality in video-assisted thoracoscopic lung segmentectomy].

    PubMed

    Onuki, Takamasa

    2009-07-01

    The branching patterns of pulmonary arteries and veins vary greatly in the pulmonary hilar region and are very complicated. We attempted to reconstruct anatomically correct images using a freeware program. After uploading the images to a personal computer, bronchi, pulmonary arteries and veins were traced by moving up and down in the images and the location and thickness of the bronchi and pulmonary vasculture were indicated as different-sized cylinders. Next, based on the resulting numerical data, a 3D image was reconstructed using Metasequoia shareware. The reconstructed images can be manipulated by virtual surgical procedures such as reshaping, cutting and moving. These system would be very helpful in complicated video-assisted thoracic surgery such as lung segmentectomy.

  6. Linear Optimization and Image Reconstruction

    DTIC Science & Technology

    1994-06-01

    final example is again a novel one. We formulate the problem of computer assisted tomographic ( CAT ) image reconstruction as a linear optimization...possibility that a patient, Fred, suffers from a brain tumor. Further, the physician opts to make use of the CAT (Computer Aided Tomography) scan device...and examine the inside of Fred’s head without exploratory surgery. The CAT scan machine works by projecting a finite number of X-rays of known

  7. Computer-assisted techniques to evaluate fringe patterns

    NASA Astrophysics Data System (ADS)

    Sciammarella, Cesar A.; Bhat, Gopalakrishna K.

    1992-01-01

    Strain measurement using interferometry requires an efficient way to extract the desired information from interferometric fringes. Availability of digital image processing systems makes it possible to use digital techniques for the analysis of fringes. In the past, there have been several developments in the area of one dimensional and two dimensional fringe analysis techniques, including the carrier fringe method (spatial heterodyning) and the phase stepping (quasi-heterodyning) technique. This paper presents some new developments in the area of two dimensional fringe analysis, including a phase stepping technique supplemented by the carrier fringe method and a two dimensional Fourier transform method to obtain the strain directly from the discontinuous phase contour map.

  8. Mobile augmented reality for computer-assisted percutaneous nephrolithotomy.

    PubMed

    Müller, Michael; Rassweiler, Marie-Claire; Klein, Jan; Seitel, Alexander; Gondan, Matthias; Baumhauer, Matthias; Teber, Dogu; Rassweiler, Jens J; Meinzer, Hans-Peter; Maier-Hein, Lena

    2013-07-01

    Percutaneous nephrolithotomy (PCNL) plays an integral role in treatment of renal stones. Creating percutaneous renal access is the most important and challenging step in the procedure. To facilitate this step, we evaluated our novel mobile augmented reality (AR) system for its feasibility of use for PCNL. A tablet computer, such as an iPad[Formula: see text], is positioned above the patient with its camera pointing toward the field of intervention. The images of the tablet camera are registered with the CT image by means of fiducial markers. Structures of interest can be superimposed semi-transparently on the video images. We present a systematic evaluation by means of a phantom study. An urological trainee and two experts conducted 53 punctures on kidney phantoms. The trainee performed best with the proposed AR system in terms of puncturing time (mean: 99 s), whereas the experts performed best with fluoroscopy (mean: 59 s). iPad assistance lowered radiation exposure by a factor of 3 for the inexperienced physician and by a factor of 1.8 for the experts in comparison with fluoroscopy usage. We achieve a mean visualization accuracy of 2.5 mm. The proposed tablet computer-based AR system has proven helpful in assisting percutaneous interventions such as PCNL and shows benefits compared to other state-of-the-art assistance systems. A drawback of the system in its current state is the lack of depth information. Despite that, the simple integration into the clinical workflow highlights the potential impact of this approach to such interventions.

  9. Interactive tele-radiological segmentation systems for treatment and diagnosis.

    PubMed

    Zimeras, S; Gortzis, L G

    2012-01-01

    Telehealth is the exchange of health information and the provision of health care services through electronic information and communications technology, where participants are separated by geographic, time, social and cultural barriers. The shift of telemedicine from desktop platforms to wireless and mobile technologies is likely to have a significant impact on healthcare in the future. It is therefore crucial to develop a general information exchange e-medical system to enables its users to perform online and offline medical consultations through diagnosis. During the medical diagnosis, image analysis techniques combined with doctor's opinions could be useful for final medical decisions. Quantitative analysis of digital images requires detection and segmentation of the borders of the object of interest. In medical images, segmentation has traditionally been done by human experts. Even with the aid of image processing software (computer-assisted segmentation tools), manual segmentation of 2D and 3D CT images is tedious, time-consuming, and thus impractical, especially in cases where a large number of objects must be specified. Substantial computational and storage requirements become especially acute when object orientation and scale have to be considered. Therefore automated or semi-automated segmentation techniques are essential if these software applications are ever to gain widespread clinical use. The main purpose of this work is to analyze segmentation techniques for the definition of anatomical structures under telemedical systems.

  10. Algorithms for Image Analysis and Combination of Pattern Classifiers with Application to Medical Diagnosis

    NASA Astrophysics Data System (ADS)

    Georgiou, Harris

    2009-10-01

    Medical Informatics and the application of modern signal processing in the assistance of the diagnostic process in medical imaging is one of the more recent and active research areas today. This thesis addresses a variety of issues related to the general problem of medical image analysis, specifically in mammography, and presents a series of algorithms and design approaches for all the intermediate levels of a modern system for computer-aided diagnosis (CAD). The diagnostic problem is analyzed with a systematic approach, first defining the imaging characteristics and features that are relevant to probable pathology in mammo-grams. Next, these features are quantified and fused into new, integrated radio-logical systems that exhibit embedded digital signal processing, in order to improve the final result and minimize the radiological dose for the patient. In a higher level, special algorithms are designed for detecting and encoding these clinically interest-ing imaging features, in order to be used as input to advanced pattern classifiers and machine learning models. Finally, these approaches are extended in multi-classifier models under the scope of Game Theory and optimum collective deci-sion, in order to produce efficient solutions for combining classifiers with minimum computational costs for advanced diagnostic systems. The material covered in this thesis is related to a total of 18 published papers, 6 in scientific journals and 12 in international conferences.

  11. Non-photorealistic rendering of virtual implant models for computer-assisted fluoroscopy-based surgical procedures

    NASA Astrophysics Data System (ADS)

    Zheng, Guoyan

    2007-03-01

    Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

  12. Unified Framework for Development, Deployment and Robust Testing of Neuroimaging Algorithms

    PubMed Central

    Joshi, Alark; Scheinost, Dustin; Okuda, Hirohito; Belhachemi, Dominique; Murphy, Isabella; Staib, Lawrence H.; Papademetris, Xenophon

    2011-01-01

    Developing both graphical and command-line user interfaces for neuroimaging algorithms requires considerable effort. Neuroimaging algorithms can meet their potential only if they can be easily and frequently used by their intended users. Deployment of a large suite of such algorithms on multiple platforms requires consistency of user interface controls, consistent results across various platforms and thorough testing. We present the design and implementation of a novel object-oriented framework that allows for rapid development of complex image analysis algorithms with many reusable components and the ability to easily add graphical user interface controls. Our framework also allows for simplified yet robust nightly testing of the algorithms to ensure stability and cross platform interoperability. All of the functionality is encapsulated into a software object requiring no separate source code for user interfaces, testing or deployment. This formulation makes our framework ideal for developing novel, stable and easy-to-use algorithms for medical image analysis and computer assisted interventions. The framework has been both deployed at Yale and released for public use in the open source multi-platform image analysis software—BioImage Suite (bioimagesuite.org). PMID:21249532

  13. [Health technology assessment report: Computer-assisted Pap test for cervical cancer screening].

    PubMed

    Della Palma, Paolo; Moresco, Luca; Giorgi Rossi, Paolo

    2012-01-01

    HEALTH PROBLEM: Cervical cancer is a disease which is highly preventable by means of Pap test screening for the precancerous lesions, which can be easily treated. Furthermore, in the near future, control of the disease will be enhanced by the vaccination which prevents the infection of those human papillomavirus types that cause the vast majority of cervical cancers. The effectiveness of screening in drastically reducing cervical cancer incidence has been clearly demonstrated. The epidemiology of cervical cancer in industrialised countries is now determined mostly by the Pap test coverage of the female population and by the ability of health systems to assure appropriate follow up after an abnormal Pap test. Today there are two fully automated systems for computer-assisted Pap test: the BD FocalPoint and the Hologic Imager. Recently, the Hologic Integrated Imager, a semi-automated system, was launched. The two fully automated systems are composed of a central scanner, where the machine examines the cytologic slide, and of one or more review stations, where the cytologists analyze the slides previously centrally scanned. The softwares used by the two systems identify the fields of interest so that the cytologists can look only at those points, automatically pointed out by the review station. Furthermore, the FocalPoint system classifies the slides according to their level of risk of containing signs of relevant lesions. Those in the upper classes--about one fifth of the slides--are labelled as « further review », while those in the lower level of risk, i.e. slides that have such a low level of risk that they can be considered as negative with no human review, are labelled as « no further review ». The aim of computer-assisted Pap test is to reduce the time of slide examination and to increase productivity. Furthermore, the number of errors due to lack of attention may decrease. Both the systems can be applied to liquidbased cytology, while only the BD Focal Point can be used on conventional smears. Cytology screening has some critical points: there is a shortage of cytologists/cytotechnicians; the quality strongly depends on the experience and ability of the cytologist; there is a subjective component in the cytological diagnosis; in highly screened populations, the prevalence of lesions is very low and the activity of cytologists is very monotonous. On the other hand, a progressive shift to molecular screening using HPV-DNA test as primary screening test is very likely in the near future; cytology will be used as triage test, dramatically reducing the number of slides to process and increasing the prevalence of lesions in those Pap tests. In this Report we assume that the diagnostic accuracy of computer-assisted Pap test is equal to the accuracy of manual Pap test and, consequently, that screening using computer-assisted Pap test has the same efficacy in reducing cervical cancer incidence and mortality. Under this assumption, the effectiveness/ benefit/utility is the same for the two screening modes, i.e. the economic analysis will be a cost minimization study. Furthermore, the screening process is identical for the two modalities in all the phases except for slide interpretation. The cost minimization analysis will be limited to the only phase differing between the two modes, i.e. the study will be a differential cost analysis between a labour-intensive strategy (traditional Pap test) and a technology-intensive strategy (the computer-assisted Pap test). Briefly, the objectives of this HTA Report are: to determine the break even point of computer-assisted Pap test systems, i.e. the volume of slides processed per year at which putting in place a computer-assisted Pap test system becomes economically convenient; to quantify the cost per Pap test in different scenarios according to screening centre activity volume, productivity of cytologist, type of cytology (conventional smear or liquid-based, fully automated or semi-automated computer-assisted); to analyse the computer-assisted Pap test in the Italian context, through a survey of the centres using the technology, collecting data useful for the sensitivity analysis of the economic evaluation; to evaluate the acceptability of the technology in the screening services; to evaluate the organizational and financial impact of the computer-assisted Pap test in different scenarios; to illustrate the ideal organization to implement computer-assisted Pap test in terms of volume of activity, productivity, and human and technological resources. to produce this Report, the following process was adopted: application to the Ministry of health for a grant « Analysis of the impact of professional involvement in evidence generation for the HTA process »; within this project, the sub-project « Cost effectiveness evaluation of the computer-assisted Pap test in the Italian screening programmes » was financed; constitution of the Working Group, which included the project coordinator, the principal investigator, and the health economist; identification of the centres using the computer-assisted Pap test and which had published scientific reports on the subject; identification of the Consulting Committee (stakeholder), which included screening programmes managers, pathologists, economists, health policy-makers, citizen organizations, and manufacturers. Once the evaluation was concluded, a plenary meeting with Working Group and Consulting Committee was held. The working group drafted the final version of this Report, which took into account the comments received. the fully automated computer-assisted Pap test has an important financial and organizational impact on screening programmes. The assessment of this health technology reached the following conclusions: according to the survey results, after some distrust, cytologists accepted the use of the machine and appreciated the reduction in interpretation time and the reliability in identifying the fields of interest; from an economic point of view, the automated computer-assisted Pap test can be convenient only with conventional smears if the screening centre has a volume of more than 49,000 slides/year and the cytologist productivity increases about threefold. It must be highlighted that it is not sufficient to adopt the automated Pap test to reach such an increase in productivity; the laboratory must be organised or re-organised to optimise the use of the review stations and the person time. In the case of liquid-based cytology, the adoption of automated computer- assisted Pap test can only increase the costs. In fact, liquid-based cytology increases the cost of consumable materials but reduces the interpretation time, even in manual screening. Consequently, the reduction of human costs is smaller in the case of computer-assisted screening. Liquid-based cytology has other implications and advantages not linked to the use of computer-assisted Pap test that should be taken into account and are beyond the scope of this Report; given that the computer-assisted Pap test reduces human costs, it may be more advantageous where the cost of cytologists is higher; given the relatively small volume of activity of screening centres in Italy, computer-assisted Pap test may be reasonable for a network using only one central scanner and several remote review stations; the use of automated computer-assisted Pap test only for quality control in a single centre is not economically sustainable. In this case as well, several centres, for example at the regional level, may form a consortium to reach a reasonable number of slides to achieve the break even point. Regarding the use of a machine rather than human intelligence to interpret the slides, some ethical issues were initially raised, but both the scientific community and healthcare professionals have accepted this technology. The identification of fields of interest by the machine is highly reproducible, reducing subjectivity in the diagnostic process. The Hologic system always includes a check by the human eye, while the FocalPoint system identifies about one fifth of the slides as No Further Review. Several studies, some of which conducted in Italy, confirmed the reliability of this classification. There is still some resistance to accept the practice of No Further Review. A check of previous slides and clinical data can be useful to make the cytologist and the clinician more confident. Computer-assisted automated Pap test may be introduced only if there is a need to increase the volume of slides screened to cover the screening target population and sufficient human resources are not available. Switching a programme using conventional slides to automatic scanning can only lead to a reduction in costs if the volume of slides per year exceeds 49,000 slides/annum and cytologist productivity is optimised to more than 20,000 slides per year. At a productivity of 15,000 or fewer, the automated computer-assisted Pap test cannot be convenient. Switching from manual screening with conventional slides to automatic scanning with liquid-based cytology cannot generate any economic saving, but the system could increase output with a given number of staff. The transition from manual to computer assisted automated screening of liquid based cytology will not generate savings and the increase in productivity will be lower than that of the switch from manual/conventional to automated/conventional. The use of biologists or pathologists as cytologists is more costly than the use of cytoscreeners. Given that the automated computer-assisted Pap test reduces human resource costs, its adoption in a model using only biologists and pathologists for screening is more economically advantageous. (ABSTRACT TRUNCATED)

  14. Noninvasive CT to Iso-C3D registration for improved intraoperative visualization in computer assisted orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Rudolph, Tobias; Ebert, Lars; Kowal, Jens

    2006-03-01

    Supporting surgeons in performing minimally invasive surgeries can be considered as one of the major goals of computer assisted surgery. Excellent intraoperative visualization is a prerequisite to achieve this aim. The Siremobil Iso-C 3D has become a widely used imaging device, which, in combination with a navigation system, enables the surgeon to directly navigate within the acquired 3D image volume without any extra registration steps. However, the image quality is rather low compared to a CT scan and the volume size (approx. 12 cm 3) limits its application. A regularly used alternative in computer assisted orthopedic surgery is to use of a preoperatively acquired CT scan to visualize the operating field. But, the additional registration step, necessary in order to use CT stacks for navigation is quite invasive. Therefore the objective of this work is to develop a noninvasive registration technique. In this article a solution is being proposed that registers a preoperatively acquired CT scan to the intraoperatively acquired Iso-C 3D image volume, thereby registering the CT to the tracked anatomy. The procedure aligns both image volumes by maximizing the mutual information, an algorithm that has already been applied to similar registration problems and demonstrated good results. Furthermore the accuracy of such a registration method was investigated in a clinical setup, integrating a navigated Iso-C 3D in combination with an tracking system. Initial tests based on cadaveric animal bone resulted in an accuracy ranging from 0.63mm to 1.55mm mean error.

  15. Diagnostic accuracy for macroscopic classification of nodular hepatocellular carcinoma: comparison of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging and angiography-assisted computed tomography.

    PubMed

    Tada, Toshifumi; Kumada, Takashi; Toyoda, Hidenori; Ito, Takanori; Sone, Yasuhiro; Okuda, Seiji; Ogawa, Sadanobu; Igura, Takumi; Imai, Yasuharu

    2015-01-01

    The macroscopic type of hepatocellular carcinoma (HCC) is a predictor of prognosis. We clarified the diagnostic value of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) in the macroscopic classification of nodular hepatocellular carcinoma (HCC) as compared to angiography-assisted computed tomography (CT). A total of 71 surgically resected nodular HCCs with a maximum diameter of ≤5 cm were investigated. HCCs were evaluated preoperatively using Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT. HCCs were pathologically classified as simple nodular (SN), SN with extranodular growth (SN-EG), or confluent multinodular (CMN). SN-EG and CMN were grouped as non-SN. Five readers independently reviewed the images using a five-point scale. We examined the accuracy of both imaging modalities in differentiating between SN and non-SN HCC. Overall, the area under the receiver operating characteristic curve (A z ) for the diagnosis of non-SN did not differ between Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT [0.879 (95% confidence interval (CI), 0.779-0.937) and 0.845 (95% CI, 0.723-0.919), respectively]. For HCCs >2 cm, the A z for Gd-EOB-DTPA-enhanced MRI was greater than 0.9. The sensitivity, specificity, and accuracy of Gd-EOB-DTPA-enhanced MRI for identifying non-SN were equal to or higher than values with angiography-assisted CT in all three categories (all tumors, ≤2 cm, and >2 cm), but the differences were not statistically significant. Using Gd-EOB-DTPA-enhanced MRI to assess the macroscopic findings in nodular HCC was equal or superior to using angiography-assisted CT.

  16. COMPUTER-ASSISTED MOTION ANALYSIS OF SPERM FROM THE COMMON CARP

    EPA Science Inventory

    Computer-assisted semen analysis (CASA) technology was applied to the measurement of sperm motility parameters in the common carp Cyprinus carpio. Activated sperm were videotaped at 200 frames s-1 and analysed with the CellTrak/S CASA research system. The percentage of motile cel...

  17. Effect of ram semen extenders and supplements on computer assisted sperm analysis parameters

    USDA-ARS?s Scientific Manuscript database

    A study evaluated the effects of ram semen extender and extender supplementation on computer assisted sperm analysis (CASA) parameters positively correlated with progressive motility. Semen collected from 5 rams was distributed across treatment combinations consisting of either TRIS citrate (T) or ...

  18. Computer-assisted stereology and automated image analysis for quantification of tumor infiltrating lymphocytes in colon cancer.

    PubMed

    Eriksen, Ann C; Andersen, Johnnie B; Kristensson, Martin; dePont Christensen, René; Hansen, Torben F; Kjær-Frifeldt, Sanne; Sørensen, Flemming B

    2017-08-29

    Precise prognostic and predictive variables allowing improved post-operative treatment stratification are missing in patients treated for stage II colon cancer (CC). Investigation of tumor infiltrating lymphocytes (TILs) may be rewarding, but the lack of a standardized analytic technique is a major concern. Manual stereological counting is considered the gold standard, but digital pathology with image analysis is preferred due to time efficiency. The purpose of this study was to compare manual stereological estimates of TILs with automatic counts obtained by image analysis, and at the same time investigate the heterogeneity of TILs. From 43 patients treated for stage II CC in 2002 three paraffin embedded, tumor containing tissue blocks were selected one of them representing the deepest invasive tumor front. Serial sections from each of the 129 blocks were immunohistochemically stained for CD3 and CD8, and the slides were scanned. Stereological estimates of the numerical density and area fraction of TILs were obtained using the computer-assisted newCAST stereology system. For the image analysis approach an app-based algorithm was developed using Visiopharm Integrator System software. For both methods the tumor areas of interest (invasive front and central area) were manually delineated by the observer. Based on all sections, the Spearman's correlation coefficients for density estimates varied from 0.9457 to 0.9638 (p < 0.0001), whereas the coefficients for area fraction estimates ranged from 0.9400 to 0.9603 (P < 0.0001). Regarding heterogeneity, intra-class correlation coefficients (ICC) for CD3+ TILs varied from 0.615 to 0.746 in the central area, and from 0.686 to 0.746 in the invasive area. ICC for CD8+ TILs varied from 0.724 to 0.775 in the central area, and from 0.746 to 0.765 in the invasive area. Exact objective and time efficient estimates of numerical densities and area fractions of CD3+ and CD8+ TILs in stage II colon cancer can be obtained by image analysis and are highly correlated to the corresponding estimates obtained by the gold standard based on stereology. Since the intra-tumoral heterogeneity was low, this method may be recommended for quantifying TILs in only one histological section representing the deepest invasive tumor front.

  19. Climate Change Discourse in Mass Media: Application of Computer-Assisted Content Analysis

    ERIC Educational Resources Information Center

    Kirilenko, Andrei P.; Stepchenkova, Svetlana O.

    2012-01-01

    Content analysis of mass media publications has become a major scientific method used to analyze public discourse on climate change. We propose a computer-assisted content analysis method to extract prevalent themes and analyze discourse changes over an extended period in an objective and quantifiable manner. The method includes the following: (1)…

  20. [Georg Schlöndorff-the father of computer-assisted surgery].

    PubMed

    Mösges, R

    2016-09-01

    Georg Schlöndorff (1931-2011) developed the idea of computer-assisted surgery (CAS) during his time as professor and chairman of the Department of Otorhinolaryngology at the Medical Faculty of the University of Aachen, Germany. In close cooperation with engineers and physicists, he succeeded in translating this concept into a functional prototype that was applied in live surgery in the operating theatre. The first intervention performed with this image-guided navigation system was a skull base surgical procedure 1987. During the following years, this concept was extended to orbital surgery, neurosurgery, mid-facial traumatology, and brachytherapy of solid tumors in the head and neck region. Further technical developments of this first prototype included touchless optical positioning and the computer vision concept with three orthogonal images, which is still common in contemporary navigation systems. During his time as emeritus professor from 1996, Georg Schlöndorff further pursued his concept of CAS by developing technical innovations such as computational fluid dynamics (CFD).

  1. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  2. A new approach of building 3D visualization framework for multimodal medical images display and computed assisted diagnosis

    NASA Astrophysics Data System (ADS)

    Li, Zhenwei; Sun, Jianyong; Zhang, Jianguo

    2012-02-01

    As more and more CT/MR studies are scanning with larger volume of data sets, more and more radiologists and clinician would like using PACS WS to display and manipulate these larger data sets of images with 3D rendering features. In this paper, we proposed a design method and implantation strategy to develop 3D image display component not only with normal 3D display functions but also with multi-modal medical image fusion as well as compute-assisted diagnosis of coronary heart diseases. The 3D component has been integrated into the PACS display workstation of Shanghai Huadong Hospital, and the clinical practice showed that it is easy for radiologists and physicians to use these 3D functions such as multi-modalities' (e.g. CT, MRI, PET, SPECT) visualization, registration and fusion, and the lesion quantitative measurements. The users were satisfying with the rendering speeds and quality of 3D reconstruction. The advantages of the component include low requirements for computer hardware, easy integration, reliable performance and comfortable application experience. With this system, the radiologists and the clinicians can manipulate with 3D images easily, and use the advanced visualization tools to facilitate their work with a PACS display workstation at any time.

  3. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  4. Computed tomography-assisted laparoscopic removal of intraabdominally migrated levonorgestrel-releasing intrauterine systems.

    PubMed

    Mahmoud, Mohamad S; Merhi, Zaher O

    2010-04-01

    To report three cases of migrated levonorgestrel intrauterine device (LNG-IUS) into the pelvic/abdominal cavity removed laparoscopically with the aid of preoperative computed tomography (CT) scan imaging. Three patients presenting with a missing LNG-IUS on examination and pelvic ultrasound are presented. A preoperative CT scan was performed, what helped in a successful removal of the LNG-IUS. The patients were discharged home the same day of the procedure. Our cases reinforce, besides the diagnosis of a migrated LNG-IUS by ultrasound, the fact that preoperative CT scan imaging assists in the diagnosis of the precise location of a migrated LNG-IUS into the pelvic/abdominal cavity and helps the physician in the prediction of the difficulty of the laparoscopic removal.

  5. Conversation Analysis in Computer-Assisted Language Learning

    ERIC Educational Resources Information Center

    González-Lloret, Marta

    2015-01-01

    The use of Conversation Analysis (CA) in the study of technology-mediated interactions is a recent methodological addition to qualitative research in the field of Computer-assisted Language Learning (CALL). The expansion of CA in Second Language Acquisition research, coupled with the need for qualitative techniques to explore how people interact…

  6. MONTHLY VARIATION IN SPERM MOTILITY IN COMMON CARP ASSESSED USING COMPUTER-ASSISTED SPERM ANALYSIS (CASA)

    EPA Science Inventory

    Sperm motility variables from the milt of the common carp Cyprinus carpio were assessed using a computer-assisted sperm analysis (CASA) system across several months (March-August 1992) known to encompass the natural spawning period. Two-year-old pond-raised males obtained each mo...

  7. Computer-Assisted Analysis of Qualitative Gerontological Research.

    ERIC Educational Resources Information Center

    Hiemstra, Roger; And Others

    1987-01-01

    Asserts that qualitative research has great potential for use in gerontological research. Describes QUALOG, a computer-assisted, qualitative data analysis scheme using logic programming developed at Syracuse University. Reviews development of QUALOG and discusses how QUALOG was used to analyze data from a qualitative study of older adult learners.…

  8. OBJECTIVE EVALUATION OF HYPERACTIVATED MOTILITY IN RAT SPERMATOZA USING COMPUTER-ASSISTED SPERM ANALYSIS (CASA)

    EPA Science Inventory

    Objective evaluation of hyperactivated motility in rat spermatozoa using computer-assisted sperm analysis.

    Cancel AM, Lobdell D, Mendola P, Perreault SD.

    Toxicology Program, University of North Carolina, Chapel Hill, NC 27599, USA.

    The aim of this study was t...

  9. A Methodological Analysis of Randomized Clinical Trials of Computer-Assisted Therapies for Psychiatric Disorders: Toward Improved Standards for an Emerging Field

    PubMed Central

    Kiluk, Brian D.; Sugarman, Dawn E.; Nich, Charla; Gibbons, Carly J.; Martino, Steve; Rounsaville, Bruce J.; Carroll, Kathleen M.

    2013-01-01

    Objective Computer-assisted therapies offer a novel, cost-effective strategy for providing evidence-based therapies to a broad range of individuals with psychiatric disorders. However, the extent to which the growing body of randomized trials evaluating computer-assisted therapies meets current standards of methodological rigor for evidence-based interventions is not clear. Method A methodological analysis of randomized clinical trials of computer-assisted therapies for adult psychiatric disorders, published between January 1990 and January 2010, was conducted. Seventy-five studies that examined computer-assisted therapies for a range of axis I disorders were evaluated using a 14-item methodological quality index. Results Results indicated marked heterogeneity in study quality. No study met all 14 basic quality standards, and three met 13 criteria. Consistent weaknesses were noted in evaluation of treatment exposure and adherence, rates of follow-up assessment, and conformity to intention-to-treat principles. Studies utilizing weaker comparison conditions (e.g., wait-list controls) had poorer methodological quality scores and were more likely to report effects favoring the computer-assisted condition. Conclusions While several well-conducted studies have indicated promising results for computer-assisted therapies, this emerging field has not yet achieved a level of methodological quality equivalent to those required for other evidence-based behavioral therapies or pharmacotherapies. Adoption of more consistent standards for methodological quality in this field, with greater attention to potential adverse events, is needed before computer-assisted therapies are widely disseminated or marketed as evidence based. PMID:21536689

  10. Digital Pathology: Data-Intensive Frontier in Medical Imaging

    PubMed Central

    Cooper, Lee A. D.; Carter, Alexis B.; Farris, Alton B.; Wang, Fusheng; Kong, Jun; Gutman, David A.; Widener, Patrick; Pan, Tony C.; Cholleti, Sharath R.; Sharma, Ashish; Kurc, Tahsin M.; Brat, Daniel J.; Saltz, Joel H.

    2013-01-01

    Pathology is a medical subspecialty that practices the diagnosis of disease. Microscopic examination of tissue reveals information enabling the pathologist to render accurate diagnoses and to guide therapy. The basic process by which anatomic pathologists render diagnoses has remained relatively unchanged over the last century, yet advances in information technology now offer significant opportunities in image-based diagnostic and research applications. Pathology has lagged behind other healthcare practices such as radiology where digital adoption is widespread. As devices that generate whole slide images become more practical and affordable, practices will increasingly adopt this technology and eventually produce an explosion of data that will quickly eclipse the already vast quantities of radiology imaging data. These advances are accompanied by significant challenges for data management and storage, but they also introduce new opportunities to improve patient care by streamlining and standardizing diagnostic approaches and uncovering disease mechanisms. Computer-based image analysis is already available in commercial diagnostic systems, but further advances in image analysis algorithms are warranted in order to fully realize the benefits of digital pathology in medical discovery and patient care. In coming decades, pathology image analysis will extend beyond the streamlining of diagnostic workflows and minimizing interobserver variability and will begin to provide diagnostic assistance, identify therapeutic targets, and predict patient outcomes and therapeutic responses. PMID:25328166

  11. Spatial and spectral analysis of corneal epithelium injury using hyperspectral images

    NASA Astrophysics Data System (ADS)

    Md Noor, Siti Salwa; Michael, Kaleena; Marshall, Stephen; Ren, Jinchang

    2017-12-01

    Eye assessment is essential in preventing blindness. Currently, the existing methods to assess corneal epithelium injury are complex and require expert knowledge. Hence, we have introduced a non-invasive technique using hyperspectral imaging (HSI) and an image analysis algorithm of corneal epithelium injury. Three groups of images were compared and analyzed, namely healthy eyes, injured eyes, and injured eyes with stain. Dimensionality reduction using principal component analysis (PCA) was applied to reduce massive data and redundancies. The first 10 principal components (PCs) were selected for further processing. The mean vector of 10 PCs with 45 pairs of all combinations was computed and sent to two classifiers. A quadratic Bayes normal classifier (QDC) and a support vector classifier (SVC) were used in this study to discriminate the eleven eyes into three groups. As a result, the combined classifier of QDC and SVC showed optimal performance with 2D PCA features (2DPCA-QDSVC) and was utilized to classify normal and abnormal tissues, using color image segmentation. The result was compared with human segmentation. The outcome showed that the proposed algorithm produced extremely promising results to assist the clinician in quantifying a cornea injury.

  12. Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splint-A novel 3D analyzing algorithm.

    PubMed

    Chin, Shih-Jan; Wilde, Frank; Neuhaus, Michael; Schramm, Alexander; Gellrich, Nils-Claudius; Rana, Majeed

    2017-12-01

    The benefit of computer-assisted planning in orthognathic surgery has been extensively documented over the last decade. This study aims to evaluate the accuracy of a virtual orthognathic surgical plan by a novel three dimensional (3D) analysis method. Ten patients who required orthognathic surgery were included in this study. A virtual surgical plan was achieved by the combination of a 3D skull model acquired from computed tomography (CT) and surface scanning of the upper and lower dental arch respectively and final occlusal position. Osteotomies and movement of maxilla and mandible were simulated by Dolphin Imaging 11.8 Premium ® (Dolphin Imaging and Management Solutions, Chatsworth, CA). The surgical plan was transferred to surgical splints fabricated by means of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). Differences of three dimensional measurements between the virtual surgical plan and postoperative results were evaluated. The results from all parameters showed that the virtual surgical plans were successfully transferred by the assistance of CAD/CAM fabricated surgical splint. Wilcoxon's signed rank test showed that no statistically significant deviation between surgical plan and post-operational result could be detected. However, deviation of angle U1 axis-HP and distance of A-CP could not fulfill the clinical success criteria. Virtual surgical planning and CAD/CAM fabricated surgical splint are proven to facilitate treatment planning and offer an accurate surgical result in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Computational and mathematical methods in brain atlasing.

    PubMed

    Nowinski, Wieslaw L

    2017-12-01

    Brain atlases have a wide range of use from education to research to clinical applications. Mathematical methods as well as computational methods and tools play a major role in the process of brain atlas building and developing atlas-based applications. Computational methods and tools cover three areas: dedicated editors for brain model creation, brain navigators supporting multiple platforms, and atlas-assisted specific applications. Mathematical methods in atlas building and developing atlas-aided applications deal with problems in image segmentation, geometric body modelling, physical modelling, atlas-to-scan registration, visualisation, interaction and virtual reality. Here I overview computational and mathematical methods in atlas building and developing atlas-assisted applications, and share my contribution to and experience in this field.

  14. [APPLICATION OF COMPUTER-ASSISTED TECHNOLOGY IN ANALYSIS OF REVISION REASON OF UNICOMPARTMENTAL KNEE ARTHROPLASTY].

    PubMed

    Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang

    2016-01-01

    To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.

  15. Automated segmentation of the lungs from high resolution CT images for quantitative study of chronic obstructive pulmonary diseases

    NASA Astrophysics Data System (ADS)

    Garg, Ishita; Karwoski, Ronald A.; Camp, Jon J.; Bartholmai, Brian J.; Robb, Richard A.

    2005-04-01

    Chronic obstructive pulmonary diseases (COPD) are debilitating conditions of the lung and are the fourth leading cause of death in the United States. Early diagnosis is critical for timely intervention and effective treatment. The ability to quantify particular imaging features of specific pathology and accurately assess progression or response to treatment with current imaging tools is relatively poor. The goal of this project was to develop automated segmentation techniques that would be clinically useful as computer assisted diagnostic tools for COPD. The lungs were segmented using an optimized segmentation threshold and the trachea was segmented using a fixed threshold characteristic of air. The segmented images were smoothed by a morphological close operation using spherical elements of different sizes. The results were compared to other segmentation approaches using an optimized threshold to segment the trachea. Comparison of the segmentation results from 10 datasets showed that the method of trachea segmentation using a fixed air threshold followed by morphological closing with spherical element of size 23x23x5 yielded the best results. Inclusion of greater number of pulmonary vessels in the lung volume is important for the development of computer assisted diagnostic tools because the physiological changes of COPD can result in quantifiable anatomic changes in pulmonary vessels. Using a fixed threshold to segment the trachea removed airways from the lungs to a better extent as compared to using an optimized threshold. Preliminary measurements gathered from patient"s CT scans suggest that segmented images can be used for accurate analysis of total lung volume and volumes of regional lung parenchyma. Additionally, reproducible segmentation allows for quantification of specific pathologic features, such as lower intensity pixels, which are characteristic of abnormal air spaces in diseases like emphysema.

  16. Visualization of the variability of 3D statistical shape models by animation.

    PubMed

    Lamecker, Hans; Seebass, Martin; Lange, Thomas; Hege, Hans-Christian; Deuflhard, Peter

    2004-01-01

    Models of the 3D shape of anatomical objects and the knowledge about their statistical variability are of great benefit in many computer assisted medical applications like images analysis, therapy or surgery planning. Statistical model of shapes have successfully been applied to automate the task of image segmentation. The generation of 3D statistical shape models requires the identification of corresponding points on two shapes. This remains a difficult problem, especially for shapes of complicated topology. In order to interpret and validate variations encoded in a statistical shape model, visual inspection is of great importance. This work describes the generation and interpretation of statistical shape models of the liver and the pelvic bone.

  17. A Comparison of Four Simulation and Instructional Methods for Endodontic Review.

    ERIC Educational Resources Information Center

    Sandoval, Victor A.; And Others

    1987-01-01

    The effects of four different endodontic self-instructional review formats (slide-tape, latent-image simulation, computer text simulation, and computer-assisted video interactive simulation) on senior clinical endodontic performance are compared. Student evaluations, as well as comparative developmental expenditures, are discussed. (Author/MLW)

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arimura, Hidetaka, E-mail: arimurah@med.kyushu-u.ac.jp; Kamezawa, Hidemi; Jin, Ze

    Good relationships between computational image analysis and radiological physics have been constructed for increasing the accuracy of medical diagnostic imaging and radiation therapy in radiological physics. Computational image analysis has been established based on applied mathematics, physics, and engineering. This review paper will introduce how computational image analysis is useful in radiation therapy with respect to radiological physics.

  19. Three-Dimensional Image Fusion of 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography and Contrast-Enhanced Computed Tomography for Computer-Assisted Planning of Maxillectomy of Recurrent Maxillary Squamous Cell Carcinoma and Defect Reconstruction.

    PubMed

    Yu, Yao; Zhang, Wen-Bo; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin

    2017-06-01

    The purpose of this study was to describe new technology assisted by 3-dimensional (3D) image fusion of 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) for computer planning of a maxillectomy of recurrent maxillary squamous cell carcinoma and defect reconstruction. Treatment of recurrent maxillary squamous cell carcinoma usually includes tumor resection and free flap reconstruction. FDG-PET/CT provided images of regions of abnormal glucose uptake and thus showed metabolic tumor volume to guide tumor resection. CECT data were used to create 3D reconstructed images of vessels to show the vascular diameters and locations, so that the most suitable vein and artery could be selected during anastomosis of the free flap. The data from preoperative maxillofacial CECT scans and FDG-PET/CT imaging were imported into the navigation system (iPlan 3.0; Brainlab, Feldkirchen, Germany). Three-dimensional image fusion between FDG-PET/CT and CECT was accomplished using Brainlab software according to the position of the 2 skulls simulated in the CECT image and PET/CT image, respectively. After verification of the image fusion accuracy, the 3D reconstruction images of the metabolic tumor, vessels, and other critical structures could be visualized within the same coordinate system. These sagittal, coronal, axial, and 3D reconstruction images were used to determine the virtual osteotomy sites and reconstruction plan, which was provided to the surgeon and used for surgical navigation. The average shift of the 3D image fusion between FDG-PET/CT and CECT was less than 1 mm. This technique, by clearly showing the metabolic tumor volume and the most suitable vessels for anastomosis, facilitated resection and reconstruction of recurrent maxillary squamous cell carcinoma. We used 3D image fusion of FDG-PET/CT and CECT to successfully accomplish resection and reconstruction of recurrent maxillary squamous cell carcinoma. This method has the potential to improve the clinical outcomes of these challenging procedures. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. EBLAST: an efficient high-compression image transformation 3. application to Internet image and video transmission

    NASA Astrophysics Data System (ADS)

    Schmalz, Mark S.; Ritter, Gerhard X.; Caimi, Frank M.

    2001-12-01

    A wide variety of digital image compression transforms developed for still imaging and broadcast video transmission are unsuitable for Internet video applications due to insufficient compression ratio, poor reconstruction fidelity, or excessive computational requirements. Examples include hierarchical transforms that require all, or large portion of, a source image to reside in memory at one time, transforms that induce significant locking effect at operationally salient compression ratios, and algorithms that require large amounts of floating-point computation. The latter constraint holds especially for video compression by small mobile imaging devices for transmission to, and compression on, platforms such as palmtop computers or personal digital assistants (PDAs). As Internet video requirements for frame rate and resolution increase to produce more detailed, less discontinuous motion sequences, a new class of compression transforms will be needed, especially for small memory models and displays such as those found on PDAs. In this, the third series of papers, we discuss the EBLAST compression transform and its application to Internet communication. Leading transforms for compression of Internet video and still imagery are reviewed and analyzed, including GIF, JPEG, AWIC (wavelet-based), wavelet packets, and SPIHT, whose performance is compared with EBLAST. Performance analysis criteria include time and space complexity and quality of the decompressed image. The latter is determined by rate-distortion data obtained from a database of realistic test images. Discussion also includes issues such as robustness of the compressed format to channel noise. EBLAST has been shown to perform superiorly to JPEG and, unlike current wavelet compression transforms, supports fast implementation on embedded processors with small memory models.

  1. Three-Dimensional Computer-Assisted Two-Layer Elastic Models of the Face.

    PubMed

    Ueda, Koichi; Shigemura, Yuka; Otsuki, Yuki; Fuse, Asuka; Mitsuno, Daisuke

    2017-11-01

    To make three-dimensional computer-assisted elastic models for the face, we decided on five requirements: (1) an elastic texture like skin and subcutaneous tissue; (2) the ability to take pen marking for incisions; (3) the ability to be cut with a surgical knife; (4) the ability to keep stitches in place for a long time; and (5) a layered structure. After testing many elastic solvents, we have made realistic three-dimensional computer-assisted two-layer elastic models of the face and cleft lip from the computed tomographic and magnetic resonance imaging stereolithographic data. The surface layer is made of polyurethane and the inner layer is silicone. Using this elastic model, we taught residents and young doctors how to make several typical local flaps and to perform cheiloplasty. They could experience realistic simulated surgery and understand three-dimensional movement of the flaps.

  2. Computer aided detection system for lung cancer using computer tomography scans

    NASA Astrophysics Data System (ADS)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  3. CT analysis of nasal volume changes after surgically-assisted rapid maxillary expansion.

    PubMed

    Tausche, Eve; Deeb, Wayel; Hansen, Lars; Hietschold, Volker; Harzer, Winfried; Schneider, Matthias

    2009-07-01

    Aim of this study was to detect the changes in nasal volume due to bone-borne, surgically-assisted rapid palatal expansion (RPE) with the Dresden Distractor using computed tomography (CT). 17 patients (mean age 28.8) underwent axial CT scanning before and 6 months after RPE. The nasal bone width was examined in the coronal plane. Cross-sectional images of the nasal cavity were taken of the area surrounding the piriform aperture, choanae and in between. Bony nasal volume was computed by connecting the three cross-sectional areas. All but two patients showed a 4.8% increase in nasal volume (SD 4.6%). The highest value, 33.3% (SD 45.1%), was measured anteriorly at the level of the nasal floor. This correlated with the midpalatal suture's V-shaped opening. There was no significant correlation between an increase in nasal volume and transverse dental arch expansion. As most of the air we breathe passes the lower nasal floor, an improvement in nasal breathing is likely.

  4. Recommendations for research design and reporting in computer-assisted diagnosis to facilitate meta-analysis.

    PubMed

    Eadie, Leila H; Taylor, Paul; Gibson, Adam P

    2012-04-01

    Computer-assisted diagnosis (CAD) describes a diverse, heterogeneous range of applications rather than a single entity. The aims and functions of CAD systems vary considerably and comparing studies and systems is challenging due to methodological and design differences. In addition, poor study quality and reporting can reduce the value of some publications. Meta-analyses of CAD are therefore difficult and may not provide reliable conclusions. Aiming to determine the major sources of heterogeneity and thereby what CAD researchers could change to allow this sort of assessment, this study reviews a sample of 147 papers concerning CAD used with imaging for cancer diagnosis. It discusses sources of variability, including the goal of the CAD system, learning methodology, study population, design, outcome measures, inclusion of radiologists, and study quality. Based upon this evidence, recommendations are made to help researchers optimize the quality and comparability of their trial design and reporting. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. A novel cost-effective computer-assisted imaging technology for accurate placement of thoracic pedicle screws.

    PubMed

    Abe, Yuichiro; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Sudo, Hideki; Minami, Akio

    2011-11-01

    Use of computer-assisted spine surgery (CASS) technologies, such as navigation systems, to improve the accuracy of pedicle screw (PS) placement is increasingly popular. Despite of their benefits, previous CASS systems are too expensive to be ubiquitously employed, and more affordable and portable systems are desirable. The aim of this study was to introduce a novel and affordable computer-assisted technique that 3-dimensionally visualizes anatomical features of the pedicles and assists in PS insertion. The authors have termed this the 3D-visual guidance technique for inserting pedicle screws (3D-VG TIPS). The 3D-VG technique for placing PSs requires only a consumer-class computer with an inexpensive 3D DICOM viewer; other special equipment is unnecessary. Preoperative CT data of the spine were collected for each patient using the 3D-VG TIPS. In this technique, the anatomical axis of each pedicle can be analyzed by volume-rendered 3D models, as with existing navigation systems, and both the ideal entry point and the trajectory of each PS can be visualized on the surface of 3D-rendered images. Intraoperative guidance slides are made from these images and displayed on a TV monitor in the operating room. The surgeon can insert PSs according to these guidance slides. The authors enrolled 30 patients with adolescent idiopathic scoliosis (AIS) who underwent posterior fusion with segmental screw fixation for validation of this technique. The novel technique allowed surgeons, from office or home, to evaluate the precise anatomy of each pedicle and the risks of screw misplacement, and to perform 3D preoperative planning for screw placement on their own computer. Looking at both 3D guidance images on a TV monitor and the bony structures of the posterior elements in each patient in the operating theater, surgeons were able to determine the best entry point for each PS with ease and confidence. Using the current technique, the screw malposition rate was 4.5% in the thoracic region in corrective surgery for AIS. The authors found that 3D-VG TIPS worked on a consumer-class computer and easily visualized the ideal entry point and trajectory of PSs in any operating theater without costly special equipment. This new technique is suitable for preoperative planning and intraoperative guidance when performing reconstructive surgery with PSs.

  6. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2007-03-01

    Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.

  7. The use of the decision tree technique and image cytometry to characterize aggressiveness in World Health Organization (WHO) grade II superficial transitional cell carcinomas of the bladder.

    PubMed

    Decaestecker, C; van Velthoven, R; Petein, M; Janssen, T; Salmon, I; Pasteels, J L; van Ham, P; Schulman, C; Kiss, R

    1996-03-01

    The aggressiveness of human bladder tumours can be assessed by means of various classification systems, including the one proposed by the World Health Organization (WHO). According to the WHO classification, three levels of malignancy are identified as grades I (low), II (intermediate), and III (high). This classification system operates satisfactorily for two of the three grades in forecasting clinical progression, most grade I tumours being associated with good prognoses and most grade III with bad. In contrast, the grade II group is very heterogeneous in terms of their clinical behaviour. The present study used two computer-assisted methods to investigate whether it is possible to sub-classify grade II tumours: computer-assisted microscope analysis (image cytometry) of Feulgen-stained nuclei and the Decision Tree Technique. This latter technique belongs to the Supervised Learning Algorithm and enables an objective assessment to be made of the diagnostic value associated with a given parameter. The combined use of these two methods in a series of 292 superficial transitional cell carcinomas shows that it is possible to identify one subgroup of grade II tumours which behave clinically like grade I tumours and a second subgroup which behaves clinically like grade III tumours. Of the nine ploidy-related parameters computed by means of image cytometry [the DNA index (DI), DNA histogram type (DHT), and the percentages of diploid, hyperdiploid, triploid, hypertriploid, tetraploid, hypertetraploid, and polyploid cell nuclei], it was the percentage of hyperdiploid and hypertetraploid cell nuclei which enabled identification, rather than conventional parameters such as the DI or the DHT.

  8. Computer-assisted diagnostic tool to quantify the pulmonary veins in sickle cell associated pulmonary hypertension

    NASA Astrophysics Data System (ADS)

    Jajamovich, Guido H.; Pamulapati, Vivek; Alam, Shoaib; Mehari, Alem; Kato, Gregory J.; Wood, Bradford J.; Linguraru, Marius George

    2012-03-01

    Pulmonary hypertension is a common cause of death among patients with sickle cell disease. This study investigates the use of pulmonary vein analysis to assist the diagnosis of pulmonary hypertension non-invasively with CT-Angiography images. The characterization of the pulmonary veins from CT presents two main challenges. Firstly, the number of pulmonary veins is unknown a priori and secondly, the contrast material is degraded when reaching the pulmonary veins, making the edges of these vessels to appear faint. Each image is first denoised and a fast marching approach is used to segment the left atrium and pulmonary veins. Afterward, a geodesic active contour is employed to isolate the left atrium. A thinning technique is then used to extract the skeleton of the atrium and the veins. The locations of the pulmonary veins ostia are determined by the intersection of the skeleton and the contour of the atrium. The diameters of the pulmonary veins are measured in each vein at fixed distances from the corresponding ostium, and for each distance, the sum of the diameters of all the veins is computed. These indicators are shown to be significantly larger in sickle-cell patients with pulmonary hypertension as compared to controls (p-values < 0.01).

  9. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    PubMed

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p < 0.05 was considered as statistically significant. Statistically significant differences were found between all of the investigated sperm parameters, except for non-progressive motility, measured with CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  10. The ImageJ ecosystem: an open platform for biomedical image analysis

    PubMed Central

    Schindelin, Johannes; Rueden, Curtis T.; Hiner, Mark C.; Eliceiri, Kevin W.

    2015-01-01

    Technology in microscopy advances rapidly, enabling increasingly affordable, faster, and more precise quantitative biomedical imaging, which necessitates correspondingly more-advanced image processing and analysis techniques. A wide range of software is available – from commercial to academic, special-purpose to Swiss army knife, small to large–but a key characteristic of software that is suitable for scientific inquiry is its accessibility. Open-source software is ideal for scientific endeavors because it can be freely inspected, modified, and redistributed; in particular, the open-software platform ImageJ has had a huge impact on life sciences, and continues to do so. From its inception, ImageJ has grown significantly due largely to being freely available and its vibrant and helpful user community. Scientists as diverse as interested hobbyists, technical assistants, students, scientific staff, and advanced biology researchers use ImageJ on a daily basis, and exchange knowledge via its dedicated mailing list. Uses of ImageJ range from data visualization and teaching to advanced image processing and statistical analysis. The software's extensibility continues to attract biologists at all career stages as well as computer scientists who wish to effectively implement specific image-processing algorithms. In this review, we use the ImageJ project as a case study of how open-source software fosters its suites of software tools, making multitudes of image-analysis technology easily accessible to the scientific community. We specifically explore what makes ImageJ so popular, how it impacts life science, how it inspires other projects, and how it is self-influenced by coevolving projects within the ImageJ ecosystem. PMID:26153368

  11. The ImageJ ecosystem: An open platform for biomedical image analysis.

    PubMed

    Schindelin, Johannes; Rueden, Curtis T; Hiner, Mark C; Eliceiri, Kevin W

    2015-01-01

    Technology in microscopy advances rapidly, enabling increasingly affordable, faster, and more precise quantitative biomedical imaging, which necessitates correspondingly more-advanced image processing and analysis techniques. A wide range of software is available-from commercial to academic, special-purpose to Swiss army knife, small to large-but a key characteristic of software that is suitable for scientific inquiry is its accessibility. Open-source software is ideal for scientific endeavors because it can be freely inspected, modified, and redistributed; in particular, the open-software platform ImageJ has had a huge impact on the life sciences, and continues to do so. From its inception, ImageJ has grown significantly due largely to being freely available and its vibrant and helpful user community. Scientists as diverse as interested hobbyists, technical assistants, students, scientific staff, and advanced biology researchers use ImageJ on a daily basis, and exchange knowledge via its dedicated mailing list. Uses of ImageJ range from data visualization and teaching to advanced image processing and statistical analysis. The software's extensibility continues to attract biologists at all career stages as well as computer scientists who wish to effectively implement specific image-processing algorithms. In this review, we use the ImageJ project as a case study of how open-source software fosters its suites of software tools, making multitudes of image-analysis technology easily accessible to the scientific community. We specifically explore what makes ImageJ so popular, how it impacts the life sciences, how it inspires other projects, and how it is self-influenced by coevolving projects within the ImageJ ecosystem. © 2015 Wiley Periodicals, Inc.

  12. Metal surface corrosion grade estimation from single image

    NASA Astrophysics Data System (ADS)

    Chen, Yijun; Qi, Lin; Sun, Huyuan; Fan, Hao; Dong, Junyu

    2018-04-01

    Metal corrosion can cause many problems, how to quickly and effectively assess the grade of metal corrosion and timely remediation is a very important issue. Typically, this is done by trained surveyors at great cost. Assisting them in the inspection process by computer vision and artificial intelligence would decrease the inspection cost. In this paper, we propose a dataset of metal surface correction used for computer vision detection and present a comparison between standard computer vision techniques by using OpenCV and deep learning method for automatic metal surface corrosion grade estimation from single image on this dataset. The test has been performed by classifying images and calculating the accuracy for the two different approaches.

  13. A PERT/CPM of the Computer Assisted Completion of The Ministry September Report. Research Report.

    ERIC Educational Resources Information Center

    Feeney, J. D.

    Using two statistical analysis techniques (the Program Evaluation and Review Technique and the Critical Path Method), this study analyzed procedures for compiling the required yearly report of the Metropolitan Separate School Board (Catholic) of Toronto, Canada. The computer-assisted analysis organized the process of completing the report more…

  14. A Computer Assisted Language Analysis System.

    ERIC Educational Resources Information Center

    Rush, J. E.; And Others

    A description is presented of a computer-assisted language analysis system (CALAS) which can serve as a method for isolating and displaying language utterances found in conversation. The purpose of CALAS is stated as being to deal with the question of whether it is possible to detect, isolate, and display information indicative of what is…

  15. Computer-assisted cytologic diagnosis in pancreatic FNA: An application of neural networks to image analysis.

    PubMed

    Momeni-Boroujeni, Amir; Yousefi, Elham; Somma, Jonathan

    2017-12-01

    Fine-needle aspiration (FNA) biopsy is an accurate method for the diagnosis of solid pancreatic masses. However, a significant number of cases still pose a diagnostic challenge. The authors have attempted to design a computer model to aid in the diagnosis of these biopsies. Images were captured of cell clusters on ThinPrep slides from 75 pancreatic FNA cases (20 malignant, 24 benign, and 31 atypical). A K-means clustering algorithm was used to segment the cell clusters into separable regions of interest before extracting features similar to those used for cytomorphologic assessment. A multilayer perceptron neural network (MNN) was trained and then tested for its ability to distinguish benign from malignant cases. A total of 277 images of cell clusters were obtained. K-means clustering identified 68,301 possible regions of interest overall. Features such as contour, perimeter, and area were found to be significantly different between malignant and benign images (P <.05). The MNN was 100% accurate for benign and malignant categories. The model's predictions from the atypical data set were 77% accurate. The results of the current study demonstrate that computer models can be used successfully to distinguish benign from malignant pancreatic cytology. The fact that the model can categorize atypical cases into benign or malignant with 77% accuracy highlights the great potential of this technology. Although further study is warranted to validate its clinical applications in pancreatic and perhaps other areas of cytology as well, the potential for improved patient outcomes using MNN for image analysis in pathology is significant. Cancer Cytopathol 2017;125:926-33. © 2017 American Cancer Society. © 2017 American Cancer Society.

  16. Image classification of human carcinoma cells using complex wavelet-based covariance descriptors.

    PubMed

    Keskin, Furkan; Suhre, Alexander; Kose, Kivanc; Ersahin, Tulin; Cetin, A Enis; Cetin-Atalay, Rengul

    2013-01-01

    Cancer cell lines are widely used for research purposes in laboratories all over the world. Computer-assisted classification of cancer cells can alleviate the burden of manual labeling and help cancer research. In this paper, we present a novel computerized method for cancer cell line image classification. The aim is to automatically classify 14 different classes of cell lines including 7 classes of breast and 7 classes of liver cancer cells. Microscopic images containing irregular carcinoma cell patterns are represented by subwindows which correspond to foreground pixels. For each subwindow, a covariance descriptor utilizing the dual-tree complex wavelet transform (DT-[Formula: see text]WT) coefficients and several morphological attributes are computed. Directionally selective DT-[Formula: see text]WT feature parameters are preferred primarily because of their ability to characterize edges at multiple orientations which is the characteristic feature of carcinoma cell line images. A Support Vector Machine (SVM) classifier with radial basis function (RBF) kernel is employed for final classification. Over a dataset of 840 images, we achieve an accuracy above 98%, which outperforms the classical covariance-based methods. The proposed system can be used as a reliable decision maker for laboratory studies. Our tool provides an automated, time- and cost-efficient analysis of cancer cell morphology to classify different cancer cell lines using image-processing techniques, which can be used as an alternative to the costly short tandem repeat (STR) analysis. The data set used in this manuscript is available as supplementary material through http://signal.ee.bilkent.edu.tr/cancerCellLineClassificationSampleImages.html.

  17. Image Classification of Human Carcinoma Cells Using Complex Wavelet-Based Covariance Descriptors

    PubMed Central

    Keskin, Furkan; Suhre, Alexander; Kose, Kivanc; Ersahin, Tulin; Cetin, A. Enis; Cetin-Atalay, Rengul

    2013-01-01

    Cancer cell lines are widely used for research purposes in laboratories all over the world. Computer-assisted classification of cancer cells can alleviate the burden of manual labeling and help cancer research. In this paper, we present a novel computerized method for cancer cell line image classification. The aim is to automatically classify 14 different classes of cell lines including 7 classes of breast and 7 classes of liver cancer cells. Microscopic images containing irregular carcinoma cell patterns are represented by subwindows which correspond to foreground pixels. For each subwindow, a covariance descriptor utilizing the dual-tree complex wavelet transform (DT-WT) coefficients and several morphological attributes are computed. Directionally selective DT-WT feature parameters are preferred primarily because of their ability to characterize edges at multiple orientations which is the characteristic feature of carcinoma cell line images. A Support Vector Machine (SVM) classifier with radial basis function (RBF) kernel is employed for final classification. Over a dataset of 840 images, we achieve an accuracy above 98%, which outperforms the classical covariance-based methods. The proposed system can be used as a reliable decision maker for laboratory studies. Our tool provides an automated, time- and cost-efficient analysis of cancer cell morphology to classify different cancer cell lines using image-processing techniques, which can be used as an alternative to the costly short tandem repeat (STR) analysis. The data set used in this manuscript is available as supplementary material through http://signal.ee.bilkent.edu.tr/cancerCellLineClassificationSampleImages.html. PMID:23341908

  18. The use of image-guidance during transsphenoidal pituitary surgery in the United States

    PubMed Central

    Chung, Thomas K.; Riley, Kristen O.

    2015-01-01

    Background: Intraoperative image guidance is a useful modality for transsphenoidal pituitary surgery. However, the outcomes associated with this technology have not been systematically evaluated. Objective: The purpose of the study was to quantify complication rates with and without the use of image guidance during transsphenoidal pituitary surgery using a nationwide database with broadly applicable results. Methods: A retrospective analysis of the Nationwide Inpatient Sample was performed from 2007 to 2011. Transsphenoidal pituitary resections for adenomas were identified by International Classification of Diseases-9th Revision, Clinical Modification code. The effect of image guidance on cerebrospinal fluid (CSF) leak complications and cost-benefit was analyzed. Results: A total of 48,848 transsphenoidal pituitary resections were identified, of which 77.5% were partial resections and 22.5% were complete. Pathologic indications included benign (89.3%), malignant primary (0.6%), and malignant secondary (0.4%). Complications included same-stay death (0.4%), CSF leak (8.8%), postoperative CSF rhinorrhea (1.9%), diabetes insipidus (12.4%), and meningitis (0.4%). Image guidance was employed in 7% (n = 3401) of all cases. When analyzed by modality, computed tomography (CT)-assisted procedures had lower CSF rhinorrhea rates (1.1%) compared with cases with no image guidance (1.9%), whereas magnetic resonance (MR)-assisted procedures had the highest rates (2.7%, χ2 p < 0.001). Rates of CSF leak demonstrated a similar pattern (CT 6.4%, no image guidance 8.9%, MR 9.2%, χ2 p < 0.001). CT-assisted surgery had significantly shorter length of stay (2.9 days) versus no image guidance (3.7 days, p < 0.001), lower total charges ($47,589 versus $62,629, p < 0.001), and lower total cost ($16,748 versus $20,530, p < 0.001). Conclusions: CT-assisted surgery is associated with a lower rate of CSF leak, shorter length of stay, and lower cost compared with patients without image guidance. Further studies that control for severity and extent of disease are warranted to confirm this finding. PMID:25975254

  19. CHARGE Image Generator: Theory of Operation and Author Language Support. Technical Report 75-3.

    ERIC Educational Resources Information Center

    Gunwaldsen, Roger L.

    The image generator function and author language software support for the CHARGE (Color Halftone Area Graphics Environment) Interactive Graphics System are described. Designed initially for use in computer-assisted instruction (CAI) systems, the CHARGE Interactive Graphics System can provide graphic displays for various applications including…

  20. Deep Learning Localizes and Identifies Polyps in Real Time with 96% Accuracy in Screening Colonoscopy.

    PubMed

    Urban, Gregor; Tripathi, Priyam; Alkayali, Talal; Mittal, Mohit; Jalali, Farid; Karnes, William; Baldi, Pierre

    2018-06-18

    The benefit of colonoscopy for colorectal cancer prevention depends on the adenoma detection rate (ADR). The ADR should reflect adenoma prevalence rate, estimated to be greater than 50% among the screening-age population. Yet the rate of adenoma detection by colonoscopists varies from 7% to 53%. It is estimated that every 1% increase in ADR reduces the risk of interval colorectal cancers by 3-6%. New strategies are needed to increase the ADR during colonoscopy. We tested the ability of computer-assisted image analysis, with convolutional neural networks (a deep learning model for image analysis), to improve polyp detection, a surrogate of ADR. We designed and trained deep convolutional neural networks (CNN) to detect polyps using a diverse and representative set of 8641 hand labeled images from screening colonoscopies collected from over 2000 patients. We tested the models on 20 colonoscopy videos with a total duration of 5 hours. Expert colonoscopists were asked to identify all polyps in 9 de-identified colonoscopy videos, selected from archived video studies, either with or without benefit of the CNN overlay. Their findings were compared with those of the CNN, using CNN-assisted expert review as the reference. When tested on manually labeled images, the CNN identified polyps with an area under the receiver operating characteristic curve (ROC-AUC) of 0.991 and an accuracy of 96.4%. In the analysis of colonoscopy videos in which 28 polyps were removed, 4 expert reviewers identified 8 additional polyps without CNN assistance that had not been removed and identified an additional 17 polyps with CNN assistance (45 in total). All polyps removed and identified by expert review were detected by the CNN. The CNN had a false-positive rate of 7%. In a set of 8641 colonoscopy images containing 4088 unique polyps the CNN identified polyps with a cross-validation accuracy of 96.4% and ROC-AUC value of 0.991. The CNN system can detect and localize polyps well within real-time constraints using an ordinary desktop machine with a contemporary graphics processing unit. This system could increase ADR and reduce interval colorectal cancers but requires validation in large multicenter trials. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  1. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    PubMed

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Apple Image Processing Educator

    NASA Technical Reports Server (NTRS)

    Gunther, F. J.

    1981-01-01

    A software system design is proposed and demonstrated with pilot-project software. The system permits the Apple II microcomputer to be used for personalized computer-assisted instruction in the digital image processing of LANDSAT images. The programs provide data input, menu selection, graphic and hard-copy displays, and both general and detailed instructions. The pilot-project results are considered to be successful indicators of the capabilities and limits of microcomputers for digital image processing education.

  3. Quantitative characterization of color Doppler images: reproducibility, accuracy, and limitations.

    PubMed

    Delorme, S; Weisser, G; Zuna, I; Fein, M; Lorenz, A; van Kaick, G

    1995-01-01

    A computer-based quantitative analysis for color Doppler images of complex vascular formations is presented. The red-green-blue-signal from an Acuson XP10 is frame-grabbed and digitized. By matching each image pixel with the color bar, color pixels are identified and assigned to the corresponding flow velocity (color value). Data analysis consists of delineation of a region of interest and calculation of the relative number of color pixels in this region (color pixel density) as well as the mean color value. The mean color value was compared to flow velocities in a flow phantom. The thyroid and carotid artery in a volunteer were repeatedly examined by a single examiner to assess intra-observer variability. The thyroids in five healthy controls were examined by three experienced physicians to assess the extent of inter-observer variability and observer bias. The correlation between the mean color value and flow velocity ranged from 0.94 to 0.96 for a range of velocities determined by pulse repetition frequency. The average deviation of the mean color value from the flow velocity was 22% to 41%, depending on the selected pulse repetition frequency (range of deviations, -46% to +66%). Flow velocity was underestimated with inadequately low pulse repetition frequency, or inadequately high reject threshold. An overestimation occurred with inadequately high pulse repetition frequency. The highest intra-observer variability was 22% (relative standard deviation) for the color pixel density, and 9.1% for the mean color value. The inter-observer variation was approximately 30% for the color pixel density, and 20% for the mean color value. In conclusion, computer assisted image analysis permits an objective description of color Doppler images. However, the user must be aware that image acquisition under in vivo conditions as well as physical and instrumental factors may considerably influence the results.

  4. Three-dimensional image reconstruction with free open-source OsiriX software in video-assisted thoracoscopic lobectomy and segmentectomy.

    PubMed

    Yao, Fei; Wang, Jian; Yao, Ju; Hang, Fangrong; Lei, Xu; Cao, Yongke

    2017-03-01

    The aim of this retrospective study was to evaluate the practice and the feasibility of Osirix, a free and open-source medical imaging software, in performing accurate video-assisted thoracoscopic lobectomy and segmentectomy. From July 2014 to April 2016, 63 patients received anatomical video-assisted thoracoscopic surgery (VATS), either lobectomy or segmentectomy, in our department. Three-dimensional (3D) reconstruction images of 61 (96.8%) patients were preoperatively obtained with contrast-enhanced computed tomography (CT). Preoperative resection simulations were accomplished with patient-individual reconstructed 3D images. For lobectomy, pulmonary lobar veins, arteries and bronchi were identified meticulously by carefully reviewing the 3D images on the display. For segmentectomy, the intrasegmental veins in the affected segment for division and the intersegmental veins to be preserved were identified on the 3D images. Patient preoperative characteristics, surgical outcomes and postoperative data were reviewed from a prospective database. The study cohort of 63 patients included 33 (52.4%) men and 30 (47.6%) women, of whom 46 (73.0%) underwent VATS lobectomy and 17 (27.0%) underwent VATS segmentectomy. There was 1 conversion from VATS lobectomy to open thoracotomy because of fibrocalcified lymph nodes. A VATS lobectomy was performed in 1 case after completing the segmentectomy because invasive adenocarcinoma was detected by intraoperative frozen-section analysis. There were no 30-day or 90-day operative mortalities CONCLUSIONS: The free, simple, and user-friendly software program Osirix can provide a 3D anatomic structure of pulmonary vessels and a clear vision into the space between the lesion and adjacent tissues, which allows surgeons to make preoperative simulations and improve the accuracy and safety of actual surgery. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Assessing the activity of sarcoidosis: quantitative /sup 67/Ga-citrate imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fajman, W.A.; Greenwald, L.V.; Staton, G.

    1984-04-01

    Three different methods of quantitating /sup 67/Ga-citrate lung images - a visual index, a computer-assisted index, and the total-lung-to-background ratio - were compared in 71 studies of patients with biopsy-proven sarcoidosis. Fifty consecutive cases were analyzed independently by two different observers using all three methods. In these studies, each index was correlated with the cell differential in the bronchoalveolar lavage fluid. The total-lung-to-background ratio proved to be the simplest to perform; correlated best with the original visual index and the percentage of lymphocytes obtained in bronchoalveolar lavage fluid. Sensitivity for detecting active disease was 84% compared with 64% and 58%more » for the visual and computer-assisted indices, respectively, with no sacrifice in specificity.« less

  6. Recent development on computer aided tissue engineering--a review.

    PubMed

    Sun, Wei; Lal, Pallavi

    2002-02-01

    The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineering, particularly, in computer-aided tissue anatomical modeling, three-dimensional (3-D) anatomy visualization and 3-D reconstruction, CAD-based anatomical modeling, computer-aided tissue classification, computer-aided tissue implantation and prototype modeling assisted surgical planning and reconstruction.

  7. Robot-assisted radical prostatectomy: Multiparametric MR imaging-directed intraoperative frozen-section analysis to reduce the rate of positive surgical margins.

    PubMed

    Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo

    2015-02-01

    To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides preliminary evidence of the positive clinical effect of multiparametric MR imaging-directed IFS analysis for patients who undergo prostatectomy. © RSNA, 2014.

  8. Virtual transplantation in designing a facial prosthesis for extensive maxillofacial defects that cross the facial midline using computer-assisted technology.

    PubMed

    Feng, Zhi-hong; Dong, Yan; Bai, Shi-zhu; Wu, Guo-feng; Bi, Yun-peng; Wang, Bo; Zhao, Yi-min

    2010-01-01

    The aim of this article was to demonstrate a novel approach to designing facial prostheses using the transplantation concept and computer-assisted technology for extensive, large, maxillofacial defects that cross the facial midline. The three-dimensional (3D) facial surface images of a patient and his relative were reconstructed using data obtained through optical scanning. Based on these images, the corresponding portion of the relative's face was transplanted to the patient's where the defect was located, which could not be rehabilitated using mirror projection, to design the virtual facial prosthesis without the eye. A 3D model of an artificial eye that mimicked the patient's remaining one was developed, transplanted, and fit onto the virtual prosthesis. A personalized retention structure for the artificial eye was designed on the virtual facial prosthesis. The wax prosthesis was manufactured through rapid prototyping, and the definitive silicone prosthesis was completed. The size, shape, and cosmetic appearance of the prosthesis were satisfactory and matched the defect area well. The patient's facial appearance was recovered perfectly with the prosthesis, as determined through clinical evaluation. The optical 3D imaging and computer-aided design/computer-assisted manufacturing system used in this study can design and fabricate facial prostheses more precisely than conventional manual sculpturing techniques. The discomfort generally associated with such conventional methods was decreased greatly. The virtual transplantation used to design the facial prosthesis for the maxillofacial defect, which crossed the facial midline, and the development of the retention structure for the eye were both feasible.

  9. Multiscale finite element modeling of sheet molding compound (SMC) composite structure based on stochastic mesostructure reconstruction

    DOE PAGES

    Chen, Zhangxing; Huang, Tianyu; Shao, Yimin; ...

    2018-03-15

    Predicting the mechanical behavior of the chopped carbon fiber Sheet Molding Compound (SMC) due to spatial variations in local material properties is critical for the structural performance analysis but is computationally challenging. Such spatial variations are induced by the material flow in the compression molding process. In this work, a new multiscale SMC modeling framework and the associated computational techniques are developed to provide accurate and efficient predictions of SMC mechanical performance. The proposed multiscale modeling framework contains three modules. First, a stochastic algorithm for 3D chip-packing reconstruction is developed to efficiently generate the SMC mesoscale Representative Volume Element (RVE)more » model for Finite Element Analysis (FEA). A new fiber orientation tensor recovery function is embedded in the reconstruction algorithm to match reconstructions with the target characteristics of fiber orientation distribution. Second, a metamodeling module is established to improve the computational efficiency by creating the surrogates of mesoscale analyses. Third, the macroscale behaviors are predicted by an efficient multiscale model, in which the spatially varying material properties are obtained based on the local fiber orientation tensors. Our approach is further validated through experiments at both meso- and macro-scales, such as tensile tests assisted by Digital Image Correlation (DIC) and mesostructure imaging.« less

  10. Multiscale finite element modeling of sheet molding compound (SMC) composite structure based on stochastic mesostructure reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Zhangxing; Huang, Tianyu; Shao, Yimin

    Predicting the mechanical behavior of the chopped carbon fiber Sheet Molding Compound (SMC) due to spatial variations in local material properties is critical for the structural performance analysis but is computationally challenging. Such spatial variations are induced by the material flow in the compression molding process. In this work, a new multiscale SMC modeling framework and the associated computational techniques are developed to provide accurate and efficient predictions of SMC mechanical performance. The proposed multiscale modeling framework contains three modules. First, a stochastic algorithm for 3D chip-packing reconstruction is developed to efficiently generate the SMC mesoscale Representative Volume Element (RVE)more » model for Finite Element Analysis (FEA). A new fiber orientation tensor recovery function is embedded in the reconstruction algorithm to match reconstructions with the target characteristics of fiber orientation distribution. Second, a metamodeling module is established to improve the computational efficiency by creating the surrogates of mesoscale analyses. Third, the macroscale behaviors are predicted by an efficient multiscale model, in which the spatially varying material properties are obtained based on the local fiber orientation tensors. Our approach is further validated through experiments at both meso- and macro-scales, such as tensile tests assisted by Digital Image Correlation (DIC) and mesostructure imaging.« less

  11. ACSYNT - A standards-based system for parametric, computer aided conceptual design of aircraft

    NASA Technical Reports Server (NTRS)

    Jayaram, S.; Myklebust, A.; Gelhausen, P.

    1992-01-01

    A group of eight US aerospace companies together with several NASA and NAVY centers, led by NASA Ames Systems Analysis Branch, and Virginia Tech's CAD Laboratory agreed, through the assistance of Americal Technology Initiative, in 1990 to form the ACSYNT (Aircraft Synthesis) Institute. The Institute is supported by a Joint Sponsored Research Agreement to continue the research and development in computer aided conceptual design of aircraft initiated by NASA Ames Research Center and Virginia Tech's CAD Laboratory. The result of this collaboration, a feature-based, parametric computer aided aircraft conceptual design code called ACSYNT, is described. The code is based on analysis routines begun at NASA Ames in the early 1970's. ACSYNT's CAD system is based entirely on the ISO standard Programmer's Hierarchical Interactive Graphics System and is graphics-device independent. The code includes a highly interactive graphical user interface, automatically generated Hermite and B-Spline surface models, and shaded image displays. Numerous features to enhance aircraft conceptual design are described.

  12. Rapid reconstruction of 3D neuronal morphology from light microscopy images with augmented rayburst sampling.

    PubMed

    Ming, Xing; Li, Anan; Wu, Jingpeng; Yan, Cheng; Ding, Wenxiang; Gong, Hui; Zeng, Shaoqun; Liu, Qian

    2013-01-01

    Digital reconstruction of three-dimensional (3D) neuronal morphology from light microscopy images provides a powerful technique for analysis of neural circuits. It is time-consuming to manually perform this process. Thus, efficient computer-assisted approaches are preferable. In this paper, we present an innovative method for the tracing and reconstruction of 3D neuronal morphology from light microscopy images. The method uses a prediction and refinement strategy that is based on exploration of local neuron structural features. We extended the rayburst sampling algorithm to a marching fashion, which starts from a single or a few seed points and marches recursively forward along neurite branches to trace and reconstruct the whole tree-like structure. A local radius-related but size-independent hemispherical sampling was used to predict the neurite centerline and detect branches. Iterative rayburst sampling was performed in the orthogonal plane, to refine the centerline location and to estimate the local radius. We implemented the method in a cooperative 3D interactive visualization-assisted system named flNeuronTool. The source code in C++ and the binaries are freely available at http://sourceforge.net/projects/flneurontool/. We validated and evaluated the proposed method using synthetic data and real datasets from the Digital Reconstruction of Axonal and Dendritic Morphology (DIADEM) challenge. Then, flNeuronTool was applied to mouse brain images acquired with the Micro-Optical Sectioning Tomography (MOST) system, to reconstruct single neurons and local neural circuits. The results showed that the system achieves a reasonable balance between fast speed and acceptable accuracy, which is promising for interactive applications in neuronal image analysis.

  13. Medical education as a science: the quality of evidence for computer-assisted instruction.

    PubMed

    Letterie, Gerard S

    2003-03-01

    A marked increase in the number of computer programs for computer-assisted instruction in the medical sciences has occurred over the past 10 years. The quality of both the programs and the literature that describe these programs has varied considerably. The purposes of this study were to evaluate the published literature that described computer-assisted instruction in medical education and to assess the quality of evidence for its implementation, with particular emphasis on obstetrics and gynecology. Reports published between 1988 and 2000 on computer-assisted instruction in medical education were identified through a search of MEDLINE and Educational Resource Identification Center and a review of the bibliographies of the articles that were identified. Studies were selected if they included a description of computer-assisted instruction in medical education, regardless of the type of computer program. Data were extracted with a content analysis of 210 reports. The reports were categorized according to study design (comparative, prospective, descriptive, review, or editorial), type of computer-assisted instruction, medical specialty, and measures of effectiveness. Computer-assisted instruction programs included online technologies, CD-ROMs, video laser disks, multimedia work stations, virtual reality, and simulation testing. Studies were identified in all medical specialties, with a preponderance in internal medicine, general surgery, radiology, obstetrics and gynecology, pediatrics, and pathology. Ninety-six percent of the articles described a favorable impact of computer-assisted instruction in medical education, regardless of the quality of the evidence. Of the 210 reports that were identified, 60% were noncomparative, descriptive reports of new techniques in computer-assisted instruction, and 15% and 14% were reviews and editorials, respectively, of existing technology. Eleven percent of studies were comparative and included some form of assessment of the effectiveness of the computer program. These assessments included pre- and posttesting and questionnaires to score program quality, perceptions of the medical students and/or residents regarding the program, and impact on learning. In one half of these comparative studies, computer-assisted instruction was compared with traditional modes of teaching, such as text and lectures. Six studies compared performance before and after the computer-assisted instruction. Improvements were shown in 5 of the studies. In the remainder of the studies, computer-assisted instruction appeared to result in similar test performance. Despite study design or outcome, most articles described enthusiastic endorsement of the programs by the participants, including medical students, residents, and practicing physicians. Only 1 study included cost analysis. Thirteen of the articles were in obstetrics and gynecology. Computer-assisted instruction has assumed to have an increasing role in medical education. In spite of enthusiastic endorsement and continued improvements in software, few studies of good design clearly demonstrate improvement in medical education over traditional modalities. There are no comparative studies in obstetrics and gynecology that demonstrate a clear-cut advantage. Future studies of computer-assisted instruction that include comparisons and cost assessments to gauge their effectiveness over traditional methods may better define their precise role.

  14. In vitro motility evaluation of aggregated cancer cells by means of automatic image processing.

    PubMed

    De Hauwer, C; Darro, F; Camby, I; Kiss, R; Van Ham, P; Decaesteker, C

    1999-05-01

    Set up of an automatic image processing based method that enables the motility of in vitro aggregated cells to be evaluated for a number of hours. Our biological model included the PC-3 human prostate cancer cell line growing as a monolayer on the bottom of Falcon plastic dishes containing conventional culture media. Our equipment consisted of an incubator, an inverted phase contrast microscope, a Charge Coupled Device (CCD) video camera, and a computer equipped with an image processing software developed in our laboratory. This computer-assisted microscope analysis of aggregated cells enables global cluster motility to be evaluated. This analysis also enables the trajectory of each cell to be isolated and parametrized within a given cluster or, indeed, the trajectories of individual cells outside a cluster. The results show that motility inside a PC-3 cluster is not restricted to slight motion due to cluster expansion, but rather consists of a marked cell movement within the cluster. The proposed equipment enables in vitro aggregated cell motility to be studied. This method can, therefore, be used in pharmacological studies in order to select anti-motility related compounds. The compounds selected by the equipment described could then be tested in vivo as potential anti-metastatic.

  15. Technography and Design-Actuality Gap-Analysis of Internet Computer Technologies-Assisted Education: Western Expectations and Global Education

    ERIC Educational Resources Information Center

    Greenhalgh-Spencer, Heather; Jerbi, Moja

    2017-01-01

    In this paper, we provide a design-actuality gap-analysis of the internet infrastructure that exists in developing nations and nations in the global South with the deployed internet computer technologies (ICT)-assisted programs that are designed to use internet infrastructure to provide educational opportunities. Programs that specifically…

  16. Computer-assisted individual osteotomy design for mandibular reconstruction

    NASA Astrophysics Data System (ADS)

    Zeilhofer, Hans-Florian U.; Sader, Robert; Horch, Hans-Henning; Wunderlich, Arthur P.; Kirsten, Rainer; Gerhardt, H. C. P.

    1994-04-01

    The complex structure and functional capacity of the mandible places high demands on the design for mandibular reconstructions for graft or transplant purposes. When using the crista iliac as a basis for grafts to bridge large defects, the graft is empirically shaped by the operator according to this experience, whereby it is often necessary to dissect and reconstruct it numerous times. A 3-D computer tomogram of the lower jaw and ilium is carried out on patients undergoing a planned mandible reconstruction. The 3-D CT data are processed in a workstation using a medical image analysis system. The ala of the ilium is superimposed over the region of the lower jaw which is to be replaced. This enables a coincidence of the structure of the lower jaw and the structure of the ilium crest to be formed to within an accuracy of one voxel - despite the complex three dimensional structure and distortions in all three spatial planes. In accordance with the computer simulation, the applicably shaped ilium crest is placed on the individually calculated donor site and transplanted in the resected section of the lower jaw. An exact reconstruction of the lower jaw bone is made possible using computer assisted individual osteotomy design, resulting in complete restoration regarding shape and functionality.

  17. From Image Analysis to Computer Vision: Motives, Methods, and Milestones.

    DTIC Science & Technology

    1998-07-01

    images. Initially, work on digital image analysis dealt with specific classes of images such as text, photomicrographs, nuclear particle tracks, and aerial...photographs; but by the 1960’s, general algorithms and paradigms for image analysis began to be formulated. When the artificial intelligence...scene, but eventually from image sequences obtained by a moving camera; at this stage, image analysis had become scene analysis or computer vision

  18. Fuzzy membership functions for analysis of high-resolution CT images of diffuse pulmonary diseases.

    PubMed

    Almeida, Eliana; Rangayyan, Rangaraj M; Azevedo-Marques, Paulo M

    2015-08-01

    We propose the use of fuzzy membership functions to analyze images of diffuse pulmonary diseases (DPDs) based on fractal and texture features. The features were extracted from preprocessed regions of interest (ROIs) selected from high-resolution computed tomography images. The ROIs represent five different patterns of DPDs and normal lung tissue. A Gaussian mixture model (GMM) was constructed for each feature, with six Gaussians modeling the six patterns. Feature selection was performed and the GMMs of the five significant features were used. From the GMMs, fuzzy membership functions were obtained by a probability-possibility transformation and further statistical analysis was performed. An average classification accuracy of 63.5% was obtained for the six classes. For four of the six classes, the classification accuracy was superior to 65%, and the best classification accuracy was 75.5% for one class. The use of fuzzy membership functions to assist in pattern classification is an alternative to deterministic approaches to explore strategies for medical diagnosis.

  19. A computational image analysis glossary for biologists.

    PubMed

    Roeder, Adrienne H K; Cunha, Alexandre; Burl, Michael C; Meyerowitz, Elliot M

    2012-09-01

    Recent advances in biological imaging have resulted in an explosion in the quality and quantity of images obtained in a digital format. Developmental biologists are increasingly acquiring beautiful and complex images, thus creating vast image datasets. In the past, patterns in image data have been detected by the human eye. Larger datasets, however, necessitate high-throughput objective analysis tools to computationally extract quantitative information from the images. These tools have been developed in collaborations between biologists, computer scientists, mathematicians and physicists. In this Primer we present a glossary of image analysis terms to aid biologists and briefly discuss the importance of robust image analysis in developmental studies.

  20. The Effects of Gender on the Attitudes towards the Computer Assisted Instruction: A Meta-Analysis

    ERIC Educational Resources Information Center

    Cam, Sefika Sumeyye; Yarar, Gokhan; Toraman, Cetin; Erdamar, Gurcu Koc

    2016-01-01

    The idea that gender factor creates a difference on computer usage and computer-assisted instruction is based upon previous years. At that time, it was thought that some areas like engineering, science and mathematics were for males so it created a difference on the computer usage. Nevertheless, developing technology and females becoming more…

  1. Preoperative (3-dimensional) computed tomography lung reconstruction before anatomic segmentectomy or lobectomy for stage I non-small cell lung cancer.

    PubMed

    Chan, Ernest G; Landreneau, James R; Schuchert, Matthew J; Odell, David D; Gu, Suicheng; Pu, Jiantao; Luketich, James D; Landreneau, Rodney J

    2015-09-01

    Accurate cancer localization and negative resection margins are necessary for successful segmentectomy. In this study, we evaluate a newly developed software package that permits automated segmentation of the pulmonary parenchyma, allowing 3-dimensional assessment of tumor size, location, and estimates of surgical margins. A pilot study using a newly developed 3-dimensional computed tomography analytic software package was performed to retrospectively evaluate preoperative computed tomography images of patients who underwent segmentectomy (n = 36) or lobectomy (n = 15) for stage 1 non-small cell lung cancer. The software accomplishes an automated reconstruction of anatomic pulmonary segments of the lung based on bronchial arborization. Estimates of anticipated surgical margins and pulmonary segmental volume were made on the basis of 3-dimensional reconstruction. Autosegmentation was achieved in 72.7% (32/44) of preoperative computed tomography images with slice thicknesses of 3 mm or less. Reasons for segmentation failure included local severe emphysema or pneumonitis, and lower computed tomography resolution. Tumor segmental localization was achieved in all autosegmented studies. The 3-dimensional computed tomography analysis provided a positive predictive value of 87% in predicting a marginal clearance greater than 1 cm and a 75% positive predictive value in predicting a margin to tumor diameter ratio greater than 1 in relation to the surgical pathology assessment. This preoperative 3-dimensional computed tomography analysis of segmental anatomy can confirm the tumor location within an anatomic segment and aid in predicting surgical margins. This 3-dimensional computed tomography information may assist in the preoperative assessment regarding the suitability of segmentectomy for peripheral lung cancers. Published by Elsevier Inc.

  2. Real-time analysis keratometer

    NASA Technical Reports Server (NTRS)

    Adachi, Iwao P. (Inventor); Adachi, Yoshifumi (Inventor); Frazer, Robert E. (Inventor)

    1987-01-01

    A computer assisted keratometer in which a fiducial line pattern reticle illuminated by CW or pulsed laser light is projected on a corneal surface through lenses, a prismoidal beamsplitter quarterwave plate, and objective optics. The reticle surface is curved as a conjugate of an ideal corneal curvature. The fiducial image reflected from the cornea undergoes a polarization shift through the quarterwave plate and beamsplitter whereby the projected and reflected beams are separated and directed orthogonally. The reflected beam fiducial pattern forms a moire pattern with a replica of the first recticle. This moire pattern contains transverse aberration due to differences in curvature between the cornea and the ideal corneal curvature. The moire pattern is analyzed in real time by computer which displays either the CW moire pattern or a pulsed mode analysis of the transverse aberration of the cornea under observation, in real time. With the eye focused on a plurality of fixation points in succession, a survey of the entire corneal topography is made and a contour map or three dimensional plot of the cornea can be made as a computer readout in addition to corneal radius and refractive power analysis.

  3. Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project

    PubMed Central

    Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe

    2016-01-01

    Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%). PMID:27042658

  4. Aberrant functional connectivity for diagnosis of major depressive disorder: a discriminant analysis.

    PubMed

    Cao, Longlong; Guo, Shuixia; Xue, Zhimin; Hu, Yong; Liu, Haihong; Mwansisya, Tumbwene E; Pu, Weidan; Yang, Bo; Liu, Chang; Feng, Jianfeng; Chen, Eric Y H; Liu, Zhening

    2014-02-01

    Aberrant brain functional connectivity patterns have been reported in major depressive disorder (MDD). It is unknown whether they can be used in discriminant analysis for diagnosis of MDD. In the present study we examined the efficiency of discriminant analysis of MDD by individualized computer-assisted diagnosis. Based on resting-state functional magnetic resonance imaging data, a new approach was adopted to investigate functional connectivity changes in 39 MDD patients and 37 well-matched healthy controls. By using the proposed feature selection method, we identified significant altered functional connections in patients. They were subsequently applied to our analysis as discriminant features using a support vector machine classification method. Furthermore, the relative contribution of functional connectivity was estimated. After subset selection of high-dimension features, the support vector machine classifier reached up to approximately 84% with leave-one-out training during the discrimination process. Through summarizing the classification contribution of functional connectivities, we obtained four obvious contribution modules: inferior orbitofrontal module, supramarginal gyrus module, inferior parietal lobule-posterior cingulated gyrus module and middle temporal gyrus-inferior temporal gyrus module. The experimental results demonstrated that the proposed method is effective in discriminating MDD patients from healthy controls. Functional connectivities might be useful as new biomarkers to assist clinicians in computer auxiliary diagnosis of MDD. © 2013 The Authors. Psychiatry and Clinical Neurosciences © 2013 Japanese Society of Psychiatry and Neurology.

  5. Fusion of an Ensemble of Augmented Image Detectors for Robust Object Detection

    PubMed Central

    Wei, Pan; Anderson, Derek T.

    2018-01-01

    A significant challenge in object detection is accurate identification of an object’s position in image space, whereas one algorithm with one set of parameters is usually not enough, and the fusion of multiple algorithms and/or parameters can lead to more robust results. Herein, a new computational intelligence fusion approach based on the dynamic analysis of agreement among object detection outputs is proposed. Furthermore, we propose an online versus just in training image augmentation strategy. Experiments comparing the results both with and without fusion are presented. We demonstrate that the augmented and fused combination results are the best, with respect to higher accuracy rates and reduction of outlier influences. The approach is demonstrated in the context of cone, pedestrian and box detection for Advanced Driver Assistance Systems (ADAS) applications. PMID:29562609

  6. Role of post-mapping computed tomography in virtual-assisted lung mapping.

    PubMed

    Sato, Masaaki; Nagayama, Kazuhiro; Kuwano, Hideki; Nitadori, Jun-Ichi; Anraku, Masaki; Nakajima, Jun

    2017-02-01

    Background Virtual-assisted lung mapping is a novel bronchoscopic preoperative lung marking technique in which virtual bronchoscopy is used to predict the locations of multiple dye markings. Post-mapping computed tomography is performed to confirm the locations of the actual markings. This study aimed to examine the accuracy of marking locations predicted by virtual bronchoscopy and elucidate the role of post-mapping computed tomography. Methods Automated and manual virtual bronchoscopy was used to predict marking locations. After bronchoscopic dye marking under local anesthesia, computed tomography was performed to confirm the actual marking locations before surgery. Discrepancies between marking locations predicted by the different methods and the actual markings were examined on computed tomography images. Forty-three markings in 11 patients were analyzed. Results The average difference between the predicted and actual marking locations was 30 mm. There was no significant difference between the latest version of the automated virtual bronchoscopy system (30.7 ± 17.2 mm) and manual virtual bronchoscopy (29.8 ± 19.1 mm). The difference was significantly greater in the upper vs. lower lobes (37.1 ± 20.1 vs. 23.0 ± 6.8 mm, for automated virtual bronchoscopy; p < 0.01). Despite this discrepancy, all targeted lesions were successfully resected using 3-dimensional image guidance based on post-mapping computed tomography reflecting the actual marking locations. Conclusions Markings predicted by virtual bronchoscopy were dislocated from the actual markings by an average of 3 cm. However, surgery was accurately performed using post-mapping computed tomography guidance, demonstrating the indispensable role of post-mapping computed tomography in virtual-assisted lung mapping.

  7. Development and validation of technique for in-vivo 3D analysis of cranial bone graft survival

    NASA Astrophysics Data System (ADS)

    Bernstein, Mark P.; Caldwell, Curtis B.; Antonyshyn, Oleh M.; Ma, Karen; Cooper, Perry W.; Ehrlich, Lisa E.

    1997-05-01

    Bone autografts are routinely employed in the reconstruction of facial deformities resulting from trauma, tumor ablation or congenital malformations. The combined use of post- operative 3D CT and SPECT imaging provides a means for quantitative in vivo evaluation of bone graft volume and osteoblastic activity. The specific objectives of this study were: (1) Determine the reliability and accuracy of interactive computer-assisted analysis of bone graft volumes based on 3D CT scans; (2) Determine the error in CT/SPECT multimodality image registration; (3) Determine the error in SPECT/SPECT image registration; and (4) Determine the reliability and accuracy of CT-guided SPECT uptake measurements in cranial bone grafts. Five human cadaver heads served as anthropomorphic models for all experiments. Four cranial defects were created in each specimen with inlay and onlay split skull bone grafts and reconstructed to skull and malar recipient sites. To acquire all images, each specimen was CT scanned and coated with Technetium doped paint. For purposes of validation, skulls were landmarked with 1/16-inch ball-bearings and Indium. This study provides a new technique relating anatomy and physiology for the analysis of cranial bone graft survival.

  8. Brain tumor classification using AFM in combination with data mining techniques.

    PubMed

    Huml, Marlene; Silye, René; Zauner, Gerald; Hutterer, Stephan; Schilcher, Kurt

    2013-01-01

    Although classification of astrocytic tumors is standardized by the WHO grading system, which is mainly based on microscopy-derived, histomorphological features, there is great interobserver variability. The main causes are thought to be the complexity of morphological details varying from tumor to tumor and from patient to patient, variations in the technical histopathological procedures like staining protocols, and finally the individual experience of the diagnosing pathologist. Thus, to raise astrocytoma grading to a more objective standard, this paper proposes a methodology based on atomic force microscopy (AFM) derived images made from histopathological samples in combination with data mining techniques. By comparing AFM images with corresponding light microscopy images of the same area, the progressive formation of cavities due to cell necrosis was identified as a typical morphological marker for a computer-assisted analysis. Using genetic programming as a tool for feature analysis, a best model was created that achieved 94.74% classification accuracy in distinguishing grade II tumors from grade IV ones. While utilizing modern image analysis techniques, AFM may become an important tool in astrocytic tumor diagnosis. By this way patients suffering from grade II tumors are identified unambiguously, having a less risk for malignant transformation. They would benefit from early adjuvant therapies.

  9. An Information and Technical Manual for the Computer-Assisted Teacher Training System (CATTS).

    ERIC Educational Resources Information Center

    Semmel, Melvyn I.; And Others

    The manual presents technical information on the computer assisted teacher training system (CATTS) which aims at developing a versatile and economical computer based teacher training system with the capability of providing immediate analysis and feedback of data relevant to teacher pupil transactions in a classroom setting. The physical…

  10. A novel concept for smart trepanation.

    PubMed

    Follmann, Axel; Korff, Alexander; Fuertjes, Tobias; Kunze, Sandra C; Schmieder, Kirsten; Radermacher, Klaus

    2012-01-01

    Trepanation of the skull is a common procedure in craniofacial and neurosurgical interventions, allowing access to the innermost cranial structures. Despite a careful advancement, injury of the dura mater represents a frequent complication during these cranial openings. The technology of computer-assisted surgery offers different support systems such as navigated tools and surgical robots. This article presents a novel technical approach toward an image- and sensor-based synergistic control of the cutting depth of a manually guided soft-tissue-preserving saw. Feasibility studies in a laboratory setup modeling relevant skull tissue parameters demonstrate that errors due to computed tomography or magnetic resonance image segmentation and registration, optical tracking, and mechanical tolerances of up to 2.5 mm, imminent to many computer-assisted surgery systems, can be compensated for by the cutting tool characteristics without damaging the dura. In conclusion, the feasibility of a computer-controlled trepanation system providing a safer and efficient trepanation has been demonstrated. Injuries of the dura mater can be avoided, and the bone cutting gap can be reduced to 0.5 mm with potential benefits for the reintegration of the bone flap.

  11. Computer-Assisted Traffic Engineering Using Assignment, Optimal Signal Setting, and Modal Split

    DOT National Transportation Integrated Search

    1978-05-01

    Methods of traffic assignment, traffic signal setting, and modal split analysis are combined in a set of computer-assisted traffic engineering programs. The system optimization and user optimization traffic assignments are described. Travel time func...

  12. Simple video format for mobile applications

    NASA Astrophysics Data System (ADS)

    Smith, John R.; Miao, Zhourong; Li, Chung-Sheng

    2000-04-01

    With the advent of pervasive computing, there is a growing demand for enabling multimedia applications on mobile devices. Large numbers of pervasive computing devices, such as personal digital assistants (PDAs), hand-held computer (HHC), smart phones, portable audio players, automotive computing devices, and wearable computers are gaining access to online information sources. However, the pervasive computing devices are often constrained along a number of dimensions, such as processing power, local storage, display size and depth, connectivity, and communication bandwidth, which makes it difficult to access rich image and video content. In this paper, we report on our initial efforts in designing a simple scalable video format with low-decoding and transcoding complexity for pervasive computing. The goal is to enable image and video access for mobile applications such as electronic catalog shopping, video conferencing, remote surveillance and video mail using pervasive computing devices.

  13. Drusen regression is associated with local changes in fundus autofluorescence in intermediate age-related macular degeneration.

    PubMed

    Toy, Brian C; Krishnadev, Nupura; Indaram, Maanasa; Cunningham, Denise; Cukras, Catherine A; Chew, Emily Y; Wong, Wai T

    2013-09-01

    To investigate the association of spontaneous drusen regression in intermediate age-related macular degeneration (AMD) with changes on fundus photography and fundus autofluorescence (FAF) imaging. Prospective observational case series. Fundus images from 58 eyes (in 58 patients) with intermediate AMD and large drusen were assessed over 2 years for areas of drusen regression that exceeded the area of circle C1 (diameter 125 μm; Age-Related Eye Disease Study grading protocol). Manual segmentation and computer-based image analysis were used to detect and delineate areas of drusen regression. Delineated regions were graded as to their appearance on fundus photographs and FAF images, and changes in FAF signal were graded manually and quantitated using automated image analysis. Drusen regression was detected in approximately half of study eyes using manual (48%) and computer-assisted (50%) techniques. At year-2, the clinical appearance of areas of drusen regression on fundus photography was mostly unremarkable, with a majority of eyes (71%) demonstrating no detectable clinical abnormalities, and the remainder (29%) showing minor pigmentary changes. However, drusen regression areas were associated with local changes in FAF that were significantly more prominent than changes on fundus photography. A majority of eyes (64%-66%) demonstrated a predominant decrease in overall FAF signal, while 14%-21% of eyes demonstrated a predominant increase in overall FAF signal. FAF imaging demonstrated that drusen regression in intermediate AMD was often accompanied by changes in local autofluorescence signal. Drusen regression may be associated with concurrent structural and physiologic changes in the outer retina. Published by Elsevier Inc.

  14. The Sounds of Nanoscience: Acoustic STM Analogues

    ERIC Educational Resources Information Center

    Euler, Manfred

    2013-01-01

    A hands-on model of scanning tunnelling microscopy (STM) is presented. It uses near-field imaging with sound and computer assisted visualization to create acoustic mappings of resonator arrangements. Due to the (partial) analogy of matter and sound waves the images closely resemble STM scans of atoms. Moreover, the method can be extended to build…

  15. Augmented reality and image overlay navigation with OsiriX in laparoscopic and robotic surgery: not only a matter of fashion.

    PubMed

    Volonté, Francesco; Pugin, François; Bucher, Pascal; Sugimoto, Maki; Ratib, Osman; Morel, Philippe

    2011-07-01

    New technologies can considerably improve preoperative planning, enhance the surgeon's skill and simplify the approach to complex procedures. Augmented reality techniques, robot assisted operations and computer assisted navigation tools will become increasingly important in surgery and in residents' education. We obtained 3D reconstructions from simple spiral computed tomography (CT) slides using OsiriX, an open source processing software package dedicated to DICOM images. These images were then projected on the patient's body with a beamer fixed to the operating table to enhance spatial perception during surgical intervention (augmented reality). Changing a window's deepness level allowed the surgeon to navigate through the patient's anatomy, highlighting regions of interest and marked pathologies. We used image overlay navigation for laparoscopic operations such cholecystectomy, abdominal exploration, distal pancreas resection and robotic liver resection. Augmented reality techniques will transform the behaviour of surgeons, making surgical interventions easier, faster and probably safer. These new techniques will also renew methods of surgical teaching, facilitating transmission of knowledge and skill to young surgeons.

  16. LSST Resources for the Community

    NASA Astrophysics Data System (ADS)

    Jones, R. Lynne

    2011-01-01

    LSST will generate 100 petabytes of images and 20 petabytes of catalogs, covering 18,000-20,000 square degrees of area sampled every few days, throughout a total of ten years of time -- all publicly available and exquisitely calibrated. The primary access to this data will be through Data Access Centers (DACs). DACs will provide access to catalogs of sources (single detections from individual images) and objects (associations of sources from multiple images). Simple user interfaces or direct SQL queries at the DAC can return user-specified portions of data from catalogs or images. More complex manipulations of the data, such as calculating multi-point correlation functions or creating alternative photo-z measurements on terabyte-scale data, can be completed with the DAC's own resources. Even more data-intensive computations requiring access to large numbers of image pixels on petabyte-scale could also be conducted at the DAC, using compute resources allocated in a similar manner to a TAC. DAC resources will be available to all individuals in member countries or institutes and LSST science collaborations. DACs will also assist investigators with requests for allocations at national facilities such as the Petascale Computing Facility, TeraGrid, and Open Science Grid. Using data on this scale requires new approaches to accessibility and analysis which are being developed through interactions with the LSST Science Collaborations. We are producing simulated images (as might be acquired by LSST) based on models of the universe and generating catalogs from these images (as well as from the base model) using the LSST data management framework in a series of data challenges. The resulting images and catalogs are being made available to the science collaborations to verify the algorithms and develop user interfaces. All LSST software is open source and available online, including preliminary catalog formats. We encourage feedback from the community.

  17. The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring - a retrospective review of 627 screws in 150 patients.

    PubMed

    Wood, Martin James; McMillen, Jason

    2014-01-01

    This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique.

  18. The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients

    PubMed Central

    McMillen, Jason

    2014-01-01

    Objective This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Methods Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Results Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. Conclusion The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. PMID:25694919

  19. Computer-assisted detection (CAD) methodology for early detection of response to pharmaceutical therapy in tuberculosis patients

    NASA Astrophysics Data System (ADS)

    Lieberman, Robert; Kwong, Heston; Liu, Brent; Huang, H. K.

    2009-02-01

    The chest x-ray radiological features of tuberculosis patients are well documented, and the radiological features that change in response to successful pharmaceutical therapy can be followed with longitudinal studies over time. The patients can also be classified as either responsive or resistant to pharmaceutical therapy based on clinical improvement. We have retrospectively collected time series chest x-ray images of 200 patients diagnosed with tuberculosis receiving the standard pharmaceutical treatment. Computer algorithms can be created to utilize image texture features to assess the temporal changes in the chest x-rays of the tuberculosis patients. This methodology provides a framework for a computer-assisted detection (CAD) system that may provide physicians with the ability to detect poor treatment response earlier in pharmaceutical therapy. Early detection allows physicians to respond with more timely treatment alternatives and improved outcomes. Such a system has the potential to increase treatment efficacy for millions of patients each year.

  20. A remote sensing computer-assisted learning tool developed using the unified modeling language

    NASA Astrophysics Data System (ADS)

    Friedrich, J.; Karslioglu, M. O.

    The goal of this work has been to create an easy-to-use and simple-to-make learning tool for remote sensing at an introductory level. Many students struggle to comprehend what seems to be a very basic knowledge of digital images, image processing and image arithmetic, for example. Because professional programs are generally too complex and overwhelming for beginners and often not tailored to the specific needs of a course regarding functionality, a computer-assisted learning (CAL) program was developed based on the unified modeling language (UML), the present standard for object-oriented (OO) system development. A major advantage of this approach is an easier transition from modeling to coding of such an application, if modern UML tools are being used. After introducing the constructed UML model, its implementation is briefly described followed by a series of learning exercises. They illustrate how the resulting CAL tool supports students taking an introductory course in remote sensing at the author's institution.

  1. Terrain matching image pre-process and its format transform in autonomous underwater navigation

    NASA Astrophysics Data System (ADS)

    Cao, Xuejun; Zhang, Feizhou; Yang, Dongkai; Yang, Bogang

    2007-06-01

    Underwater passive navigation technology is one of the important development orientations in the field of modern navigation. With the advantage of high self-determination, stealth at sea, anti-jamming and high precision, passive navigation is completely meet with actual navigation requirements. Therefore passive navigation has become a specific navigating method for underwater vehicles. The scientists and researchers in the navigating field paid more attention to it. The underwater passive navigation can provide accurate navigation information with main Inertial Navigation System (INS) for a long period, such as location and speed. Along with the development of micro-electronics technology, the navigation of AUV is given priority to INS assisted with other navigation methods, such as terrain matching navigation. It can provide navigation ability for a long period, correct the errors of INS and make AUV not emerge from the seabed termly. With terrain matching navigation technique, in the assistance of digital charts and ocean geographical characteristics sensors, we carry through underwater image matching assistant navigation to obtain the higher location precision, therefore it is content with the requirement of underwater, long-term, high precision and all-weather of the navigation system for Autonomous Underwater Vehicles. Tertian-assistant navigation (TAN) is directly dependent on the image information (map information) in the navigating field to assist the primary navigation system according to the path appointed in advance. In TAN, a factor coordinative important with the system operation is precision and practicability of the storable images and the database which produce the image data. If the data used for characteristics are not suitable, the system navigation precision will be low. Comparing with terrain matching assistant navigation system, image matching navigation system is a kind of high precision and low cost assistant navigation system, and its matching precision directly influences the final precision of integrated navigation system. Image matching assistant navigation is spatially matching and aiming at two underwater scenery images coming from two different sensors matriculating of the same scenery in order to confirm the relative displacement of the two images. In this way, we can obtain the vehicle's location in fiducial image known geographical relation, and the precise location information given from image matching location is transmitted to INS to eliminate its location error and greatly enhance the navigation precision of vehicle. Digital image data analysis and processing of image matching in underwater passive navigation is important. In regard to underwater geographic data analysis, we focus on the acquirement, disposal, analysis, expression and measurement of database information. These analysis items structure one of the important contents of underwater terrain matching and are propitious to know the seabed terrain configuration of navigation areas so that the best advantageous seabed terrain district and dependable navigation algorithm can be selected. In this way, we can improve the precision and reliability of terrain assistant navigation system. The pre-process and format transformation of digital image during underwater image matching are expatiated in this paper. The information of the terrain status in navigation areas need further study to provide the reliable data terrain characteristic and underwater overcast for navigation. Through realizing the choice of sea route, danger district prediction and navigating algorithm analysis, TAN can obtain more high location precision and probability, hence provide technological support for image matching of underwater passive navigation.

  2. Image-guided techniques in renal and hepatic interventions.

    PubMed

    Najmaei, Nima; Mostafavi, Kamal; Shahbazi, Sahar; Azizian, Mahdi

    2013-12-01

    Development of new imaging technologies and advances in computing power have enabled the physicians to perform medical interventions on the basis of high-quality 3D and/or 4D visualization of the patient's organs. Preoperative imaging has been used for planning the surgery, whereas intraoperative imaging has been widely employed to provide visual feedback to a clinician when he or she is performing the procedure. In the past decade, such systems demonstrated great potential in image-guided minimally invasive procedures on different organs, such as brain, heart, liver and kidneys. This article focuses on image-guided interventions and surgery in renal and hepatic surgeries. A comprehensive search of existing electronic databases was completed for the period of 2000-2011. Each contribution was assessed by the authors for relevance and inclusion. The contributions were categorized on the basis of the type of operation/intervention, imaging modality and specific techniques such as image fusion and augmented reality, and organ motion tracking. As a result, detailed classification and comparative study of various contributions in image-guided renal and hepatic interventions are provided. In addition, the potential future directions have been sketched. With a detailed review of the literature, potential future trends in development of image-guided abdominal interventions are identified, namely, growing use of image fusion and augmented reality, computer-assisted and/or robot-assisted interventions, development of more accurate registration and navigation techniques, and growing applications of intraoperative magnetic resonance imaging. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Web-Based Architecture to Enable Compute-Intensive CAD Tools and Multi-user Synchronization in Teleradiology

    NASA Astrophysics Data System (ADS)

    Mehta, Neville; Kompalli, Suryaprakash; Chaudhary, Vipin

    Teleradiology is the electronic transmission of radiological patient images, such as x-rays, CT, or MR across multiple locations. The goal could be interpretation, consultation, or medical records keeping. Information technology solutions have enabled electronic records and their associated benefits are evident in health care today. However, salient aspects of collaborative interfaces, and computer assisted diagnostic (CAD) tools are yet to be integrated into workflow designs. The Computer Assisted Diagnostics and Interventions (CADI) group at the University at Buffalo has developed an architecture that facilitates web-enabled use of CAD tools, along with the novel concept of synchronized collaboration. The architecture can support multiple teleradiology applications and case studies are presented here.

  4. Investigation of the effects of miniscrew-assisted rapid palatal expansion on airflow in the upper airway of an adult patient with obstructive sleep apnea syndrome using computational fluid-structure interaction analysis

    PubMed Central

    Hur, Jae-Sik; Kim, Hyoung-Ho; Choi, Jin-Young; Suh, Sang-Ho

    2017-01-01

    Objective The objective of this study was to investigate the effects of miniscrew-assisted rapid palatal expansion (MARPE) on changes in airflow in the upper airway (UA) of an adult patient with obstructive sleep apnea syndrome (OSAS) using computational fluid-structure interaction analysis. Methods Three-dimensional UA models fabricated from cone beam computed tomography images obtained before (T0) and after (T1) MARPE in an adult patient with OSAS were used for computational fluid dynamics with fluid-structure interaction analysis. Seven and nine cross-sectional planes (interplane distance of 10 mm) in the nasal cavity (NC) and pharynx, respectively, were set along UA. Changes in the cross-sectional area and changes in airflow velocity and pressure, node displacement, and total resistance at maximum inspiration (MI), rest, and maximum expiration (ME) were investigated at each plane after MARPE. Results The cross-sectional areas at most planes in NC and the upper half of the pharynx were significantly increased at T1. Moreover, airflow velocity decreased in the anterior NC at MI and ME and in the nasopharynx and oropharynx at MI. The decrease in velocity was greater in NC than in the pharynx. The airflow pressure in the anterior NC and entire pharynx exhibited a decrease at T1. The amount of node displacement in NC and the pharynx was insignificant at both T0 and T1. Absolute values for the total resistance at MI, rest, and ME were lower at T1 than at T0. Conclusions MARPE improves airflow and decreases resistance in UA; therefore, it may be an effective treatment modality for adult patients with moderate OSAS. PMID:29090123

  5. The Role of Computer-Assisted Technology in Post-Traumatic Orbital Reconstruction: A PRISMA-driven Systematic Review.

    PubMed

    Wan, Kelvin H; Chong, Kelvin K L; Young, Alvin L

    2015-12-08

    Post-traumatic orbital reconstruction remains a surgical challenge and requires careful preoperative planning, sound anatomical knowledge and good intraoperative judgment. Computer-assisted technology has the potential to reduce error and subjectivity in the management of these complex injuries. A systematic review of the literature was conducted to explore the emerging role of computer-assisted technologies in post-traumatic orbital reconstruction, in terms of functional and safety outcomes. We searched for articles comparing computer-assisted procedures with conventional surgery and studied outcomes on diplopia, enophthalmos, or procedure-related complications. Six observational studies with 273 orbits at a mean follow-up of 13 months were included. Three out of 4 studies reported significantly fewer patients with residual diplopia in the computer-assisted group, while only 1 of the 5 studies reported better improvement in enophthalmos in the assisted group. Types and incidence of complications were comparable. Study heterogeneities limiting statistical comparison by meta-analysis will be discussed. This review highlights the scarcity of data on computer-assisted technology in orbital reconstruction. The result suggests that computer-assisted technology may offer potential advantage in treating diplopia while its role remains to be confirmed in enophthalmos. Additional well-designed and powered randomized controlled trials are much needed.

  6. Development of a femoral template for computer-assisted tunnel placement in anatomical double-bundle ACL reconstruction.

    PubMed

    Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N

    2011-01-01

    Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.

  7. Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

    PubMed

    Sasso, Rick C; Best, Natalie M; Potts, Eric A

    2005-01-01

    Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

  8. A Computer-Assisted Test Design and Diagnosis System for Use by Classroom Teachers

    ERIC Educational Resources Information Center

    He, Q.; Tymms, P.

    2005-01-01

    Computer-assisted assessment (CAA) has become increasingly important in education in recent years. A variety of computer software systems have been developed to help assess the performance of students at various levels. However, such systems are primarily designed to provide objective assessment of students and analysis of test items, and focus…

  9. Landsat data availability from the EROS Data Center and status of future plans

    USGS Publications Warehouse

    Pohl, Russell A.; Metz, G.G.

    1977-01-01

    The Department of Interior's EROS Data Center, managed by the U.S. Geological Survey, was established in 1972, in Sioux Falls, South Dakota, to serve as a principal dissemination facility for Landsat and other remotely Sensed data. Through the middle of 1977, the Center has supplied approximately 1.7 million copies of images from the more than 5 million images of the Earth's surface archived at the Center. Landsat accounted for half of these images plus approximately 5,800 computer-compatible tapes of Landsat data were also supplied to users. New methods for processing data products to make them more useful are being developed, and new accession aids for determining data availability are being placed in operation. The Center also provides assistance and training to resource specialists and land managers in the use of Landsat and other remotely sensed data. A Data Analysis Laboratory is operated at the Center to provide both digital and analog multispectral/multitemporal image analysis capabilities in support of the training and assistance programs. In addition to conventionally processed data products, radiometrically enhanced Landsat imagery are now available from the Center in limited quantities. In mid-1978, the Center will convert to an all-digital processing system for Landsat data that will provide improved products for user analysis in production quantities. The Department of Interior and NASA are currently studying concepts that use communication satellites to relay Landsat data between U.S. ground stations, Goddard Space Flight Center and the EROS Data Center which would improve the timeliness of data availability. The Data Center also works closely with the remote sensing programs and Landsat data receiving and processing facilities being developed in foreign countries.

  10. Optic disc detection and boundary extraction in retinal images.

    PubMed

    Basit, A; Fraz, Muhammad Moazam

    2015-04-10

    With the development of digital image processing, analysis and modeling techniques, automatic retinal image analysis is emerging as an important screening tool for early detection of ophthalmologic disorders such as diabetic retinopathy and glaucoma. In this paper, a robust method for optic disc detection and extraction of the optic disc boundary is proposed to help in the development of computer-assisted diagnosis and treatment of such ophthalmic disease. The proposed method is based on morphological operations, smoothing filters, and the marker controlled watershed transform. Internal and external markers are used to first modify the gradient magnitude image and then the watershed transformation is applied on this modified gradient magnitude image for boundary extraction. This method has shown significant improvement over existing methods in terms of detection and boundary extraction of the optic disc. The proposed method has optic disc detection success rate of 100%, 100%, 100% and 98.9% for the DRIVE, Shifa, CHASE_DB1, and DIARETDB1 databases, respectively. The optic disc boundary detection achieved an average spatial overlap of 61.88%, 70.96%, 45.61%, and 54.69% for these databases, respectively, which are higher than currents methods.

  11. Content-based image retrieval for interstitial lung diseases using classification confidence

    NASA Astrophysics Data System (ADS)

    Dash, Jatindra Kumar; Mukhopadhyay, Sudipta; Prabhakar, Nidhi; Garg, Mandeep; Khandelwal, Niranjan

    2013-02-01

    Content Based Image Retrieval (CBIR) system could exploit the wealth of High-Resolution Computed Tomography (HRCT) data stored in the archive by finding similar images to assist radiologists for self learning and differential diagnosis of Interstitial Lung Diseases (ILDs). HRCT findings of ILDs are classified into several categories (e.g. consolidation, emphysema, ground glass, nodular etc.) based on their texture like appearances. Therefore, analysis of ILDs is considered as a texture analysis problem. Many approaches have been proposed for CBIR of lung images using texture as primitive visual content. This paper presents a new approach to CBIR for ILDs. The proposed approach makes use of a trained neural network (NN) to find the output class label of query image. The degree of confidence of the NN classifier is analyzed using Naive Bayes classifier that dynamically takes a decision on the size of the search space to be used for retrieval. The proposed approach is compared with three simple distance based and one classifier based texture retrieval approaches. Experimental results show that the proposed technique achieved highest average percentage precision of 92.60% with lowest standard deviation of 20.82%.

  12. An automated method for accurate vessel segmentation.

    PubMed

    Yang, Xin; Liu, Chaoyue; Le Minh, Hung; Wang, Zhiwei; Chien, Aichi; Cheng, Kwang-Ting Tim

    2017-05-07

    Vessel segmentation is a critical task for various medical applications, such as diagnosis assistance of diabetic retinopathy, quantification of cerebral aneurysm's growth, and guiding surgery in neurosurgical procedures. Despite technology advances in image segmentation, existing methods still suffer from low accuracy for vessel segmentation in the two challenging while common scenarios in clinical usage: (1) regions with a low signal-to-noise-ratio (SNR), and (2) at vessel boundaries disturbed by adjacent non-vessel pixels. In this paper, we present an automated system which can achieve highly accurate vessel segmentation for both 2D and 3D images even under these challenging scenarios. Three key contributions achieved by our system are: (1) a progressive contrast enhancement method to adaptively enhance contrast of challenging pixels that were otherwise indistinguishable, (2) a boundary refinement method to effectively improve segmentation accuracy at vessel borders based on Canny edge detection, and (3) a content-aware region-of-interests (ROI) adjustment method to automatically determine the locations and sizes of ROIs which contain ambiguous pixels and demand further verification. Extensive evaluation of our method is conducted on both 2D and 3D datasets. On a public 2D retinal dataset (named DRIVE (Staal 2004 IEEE Trans. Med. Imaging 23 501-9)) and our 2D clinical cerebral dataset, our approach achieves superior performance to the state-of-the-art methods including a vesselness based method (Frangi 1998 Int. Conf. on Medical Image Computing and Computer-Assisted Intervention) and an optimally oriented flux (OOF) based method (Law and Chung 2008 European Conf. on Computer Vision). An evaluation on 11 clinical 3D CTA cerebral datasets shows that our method can achieve 94% average accuracy with respect to the manual segmentation reference, which is 23% to 33% better than the five baseline methods (Yushkevich 2006 Neuroimage 31 1116-28; Law and Chung 2008 European Conf. on Computer Vision; Law and Chung 2009 IEEE Trans. Image Process. 18 596-612; Wang 2015 J. Neurosci. Methods 241 30-6) with manually optimized parameters. Our system has also been applied clinically for cerebral aneurysm development analysis. Experimental results on 10 patients' data, with two 3D CT scans per patient, show that our system's automatic diagnosis outcomes are consistent with clinicians' manual measurements.

  13. An automated method for accurate vessel segmentation

    NASA Astrophysics Data System (ADS)

    Yang, Xin; Liu, Chaoyue; Le Minh, Hung; Wang, Zhiwei; Chien, Aichi; (Tim Cheng, Kwang-Ting

    2017-05-01

    Vessel segmentation is a critical task for various medical applications, such as diagnosis assistance of diabetic retinopathy, quantification of cerebral aneurysm’s growth, and guiding surgery in neurosurgical procedures. Despite technology advances in image segmentation, existing methods still suffer from low accuracy for vessel segmentation in the two challenging while common scenarios in clinical usage: (1) regions with a low signal-to-noise-ratio (SNR), and (2) at vessel boundaries disturbed by adjacent non-vessel pixels. In this paper, we present an automated system which can achieve highly accurate vessel segmentation for both 2D and 3D images even under these challenging scenarios. Three key contributions achieved by our system are: (1) a progressive contrast enhancement method to adaptively enhance contrast of challenging pixels that were otherwise indistinguishable, (2) a boundary refinement method to effectively improve segmentation accuracy at vessel borders based on Canny edge detection, and (3) a content-aware region-of-interests (ROI) adjustment method to automatically determine the locations and sizes of ROIs which contain ambiguous pixels and demand further verification. Extensive evaluation of our method is conducted on both 2D and 3D datasets. On a public 2D retinal dataset (named DRIVE (Staal 2004 IEEE Trans. Med. Imaging 23 501-9)) and our 2D clinical cerebral dataset, our approach achieves superior performance to the state-of-the-art methods including a vesselness based method (Frangi 1998 Int. Conf. on Medical Image Computing and Computer-Assisted Intervention) and an optimally oriented flux (OOF) based method (Law and Chung 2008 European Conf. on Computer Vision). An evaluation on 11 clinical 3D CTA cerebral datasets shows that our method can achieve 94% average accuracy with respect to the manual segmentation reference, which is 23% to 33% better than the five baseline methods (Yushkevich 2006 Neuroimage 31 1116-28; Law and Chung 2008 European Conf. on Computer Vision; Law and Chung 2009 IEEE Trans. Image Process. 18 596-612; Wang 2015 J. Neurosci. Methods 241 30-6) with manually optimized parameters. Our system has also been applied clinically for cerebral aneurysm development analysis. Experimental results on 10 patients’ data, with two 3D CT scans per patient, show that our system’s automatic diagnosis outcomes are consistent with clinicians’ manual measurements.

  14. A new approach to develop computer-aided detection schemes of digital mammograms

    NASA Astrophysics Data System (ADS)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  15. Driving into the future: how imaging technology is shaping the future of cars

    NASA Astrophysics Data System (ADS)

    Zhang, Buyue

    2015-03-01

    Fueled by the development of advanced driver assistance system (ADAS), autonomous vehicles, and the proliferation of cameras and sensors, automotive is becoming a rich new domain for innovations in imaging technology. This paper presents an overview of ADAS, the important imaging and computer vision problems to solve for automotive, and examples of how some of these problems are solved, through which we highlight the challenges and opportunities in the automotive imaging space.

  16. Computer assisted diagnosis in renal nuclear medicine: rationale, methodology and interpretative criteria for diuretic renography

    PubMed Central

    Taylor, Andrew T; Garcia, Ernest V

    2014-01-01

    The goal of artificial intelligence, expert systems, decision support systems and computer assisted diagnosis (CAD) in imaging is the development and implementation of software to assist in the detection and evaluation of abnormalities, to alert physicians to cognitive biases, to reduce intra and inter-observer variability and to facilitate the interpretation of studies at a faster rate and with a higher level of accuracy. These developments are needed to meet the challenges resulting from a rapid increase in the volume of diagnostic imaging studies coupled with a concurrent increase in the number and complexity of images in each patient data. The convergence of an expanding knowledge base and escalating time constraints increases the likelihood of physician errors. Errors are even more likely when physicians interpret low volume studies such as 99mTc-MAG3 diuretic scans where imagers may have had limited training or experience. Decision support systems include neural networks, case-based reasoning, expert systems and statistical systems. iRENEX (renal expert) is an expert system for diuretic renography that uses a set of rules obtained from human experts to analyze a knowledge base of both clinical parameters and quantitative parameters derived from the renogram. Initial studies have shown that the interpretations provided by iRENEX are comparable to the interpretations of a panel of experts. iRENEX provides immediate patient specific feedback at the time of scan interpretation, can be queried to provide the reasons for its conclusions and can be used as an educational tool to teach trainees to better interpret renal scans. iRENEX also has the capacity to populate a structured reporting module and generate a clear and concise impression based on the elements contained in the report; adherence to the procedural and data entry components of the structured reporting module assures and documents procedural competency. Finally, although the focus is CAD applied to diuretic renography, this review offers a window into the rationale, methodology and broader applications of computer assisted diagnosis in medical imaging. PMID:24484751

  17. Remote sensing: a tool for park planning and management

    USGS Publications Warehouse

    Draeger, William C.; Pettinger, Lawrence R.

    1981-01-01

    Remote sensing may be defined as the science of imaging or measuring objects from a distance. More commonly, however, the term is used in reference to the acquisition and use of photographs, photo-like images, and other data acquired from aircraft and satellites. Thus, remote sensing includes the use of such diverse materials as photographs taken by hand from a light aircraft, conventional aerial photographs obtained with a precision mapping camera, satellite images acquired with sophisticated scanning devices, radar images, and magnetic and gravimetric data that may not even be in image form. Remotely sensed images may be color or black and white, can vary in scale from those that cover only a few hectares of the earth's surface to those that cover tens of thousands of square kilometers, and they may be interpreted visually or with the assistance of computer systems. This article attempts to describe several of the commonly available types of remotely sensed data, to discuss approaches to data analysis, and to demonstrate (with image examples) typical applications that might interest managers of parks and natural areas.

  18. [Cost analysis for navigation in knee endoprosthetics].

    PubMed

    Cerha, O; Kirschner, S; Günther, K-P; Lützner, J

    2009-12-01

    Total knee arthroplasty (TKA) is one of the most frequent procedures in orthopaedic surgery. The outcome depends on a range of factors including alignment of the leg and the positioning of the implant in addition to patient-associated factors. Computer-assisted navigation systems can improve the restoration of a neutral leg alignment. This procedure has been established especially in Europe and North America. The additional expenses are not reimbursed in the German DRG system (Diagnosis Related Groups). In the present study a cost analysis of computer-assisted TKA compared to the conventional technique was performed. The acquisition expenses of various navigation systems (5 and 10 year depreciation), annual costs for maintenance and software updates as well as the accompanying costs per operation (consumables, additional operating time) were considered. The additional operating time was determined on the basis of a meta-analysis according to the current literature. Situations with 25, 50, 100, 200 and 500 computer-assisted TKAs per year were simulated. The amount of the incremental costs of the computer-assisted TKA depends mainly on the annual volume and the additional operating time. A relevant decrease of the incremental costs was detected between 50 and 100 procedures per year. In a model with 100 computer-assisted TKAs per year an additional operating time of 14 mins and a 10 year depreciation of the investment costs, the incremental expenses amount to 300-395 depending on the navigation system. Computer-assisted TKA is associated with additional costs. From an economical point of view an amount of more than 50 procedures per year appears to be favourable. The cost-effectiveness could be estimated if long-term results will show a reduction of revisions or a better clinical outcome.

  19. Cybernetic Serendipity: Behind the Paradox of Machine Assisted Art Lies a Boundless World of Creativity.

    ERIC Educational Resources Information Center

    Peterson, Dale

    1984-01-01

    Discusses the works of Darcy Gerbarg, Ruth Leavitt, David Em, Duane Palyka, and Harold Cohen, visual artists who work with computers to create art works by relying on standard hardware/software tools, using custom tools created for nonartistic tasks, manipulating images at the programing level, and programing creativity into computers themselves.…

  20. A hierarchical knowledge-based approach for retrieving similar medical images described with semantic annotations

    PubMed Central

    Kurtz, Camille; Beaulieu, Christopher F.; Napel, Sandy; Rubin, Daniel L.

    2014-01-01

    Computer-assisted image retrieval applications could assist radiologist interpretations by identifying similar images in large archives as a means to providing decision support. However, the semantic gap between low-level image features and their high level semantics may impair the system performances. Indeed, it can be challenging to comprehensively characterize the images using low-level imaging features to fully capture the visual appearance of diseases on images, and recently the use of semantic terms has been advocated to provide semantic descriptions of the visual contents of images. However, most of the existing image retrieval strategies do not consider the intrinsic properties of these terms during the comparison of the images beyond treating them as simple binary (presence/absence) features. We propose a new framework that includes semantic features in images and that enables retrieval of similar images in large databases based on their semantic relations. It is based on two main steps: (1) annotation of the images with semantic terms extracted from an ontology, and (2) evaluation of the similarity of image pairs by computing the similarity between the terms using the Hierarchical Semantic-Based Distance (HSBD) coupled to an ontological measure. The combination of these two steps provides a means of capturing the semantic correlations among the terms used to characterize the images that can be considered as a potential solution to deal with the semantic gap problem. We validate this approach in the context of the retrieval and the classification of 2D regions of interest (ROIs) extracted from computed tomographic (CT) images of the liver. Under this framework, retrieval accuracy of more than 0.96 was obtained on a 30-images dataset using the Normalized Discounted Cumulative Gain (NDCG) index that is a standard technique used to measure the effectiveness of information retrieval algorithms when a separate reference standard is available. Classification results of more than 95% were obtained on a 77-images dataset. For comparison purpose, the use of the Earth Mover's Distance (EMD), which is an alternative distance metric that considers all the existing relations among the terms, led to results retrieval accuracy of 0.95 and classification results of 93% with a higher computational cost. The results provided by the presented framework are competitive with the state-of-the-art and emphasize the usefulness of the proposed methodology for radiology image retrieval and classification. PMID:24632078

  1. Anatomy assisted PET image reconstruction incorporating multi-resolution joint entropy

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Rahmim, Arman

    2015-01-01

    A promising approach in PET image reconstruction is to incorporate high resolution anatomical information (measured from MR or CT) taking the anato-functional similarity measures such as mutual information or joint entropy (JE) as the prior. These similarity measures only classify voxels based on intensity values, while neglecting structural spatial information. In this work, we developed an anatomy-assisted maximum a posteriori (MAP) reconstruction algorithm wherein the JE measure is supplied by spatial information generated using wavelet multi-resolution analysis. The proposed wavelet-based JE (WJE) MAP algorithm involves calculation of derivatives of the subband JE measures with respect to individual PET image voxel intensities, which we have shown can be computed very similarly to how the inverse wavelet transform is implemented. We performed a simulation study with the BrainWeb phantom creating PET data corresponding to different noise levels. Realistically simulated T1-weighted MR images provided by BrainWeb modeling were applied in the anatomy-assisted reconstruction with the WJE-MAP algorithm and the intensity-only JE-MAP algorithm. Quantitative analysis showed that the WJE-MAP algorithm performed similarly to the JE-MAP algorithm at low noise level in the gray matter (GM) and white matter (WM) regions in terms of noise versus bias tradeoff. When noise increased to medium level in the simulated data, the WJE-MAP algorithm started to surpass the JE-MAP algorithm in the GM region, which is less uniform with smaller isolated structures compared to the WM region. In the high noise level simulation, the WJE-MAP algorithm presented clear improvement over the JE-MAP algorithm in both the GM and WM regions. In addition to the simulation study, we applied the reconstruction algorithms to real patient studies involving DPA-173 PET data and Florbetapir PET data with corresponding T1-MPRAGE MRI images. Compared to the intensity-only JE-MAP algorithm, the WJE-MAP algorithm resulted in comparable regional mean values to those from the maximum likelihood algorithm while reducing noise. Achieving robust performance in various noise-level simulation and patient studies, the WJE-MAP algorithm demonstrates its potential in clinical quantitative PET imaging.

  2. NeuroManager: a workflow analysis based simulation management engine for computational neuroscience

    PubMed Central

    Stockton, David B.; Santamaria, Fidel

    2015-01-01

    We developed NeuroManager, an object-oriented simulation management software engine for computational neuroscience. NeuroManager automates the workflow of simulation job submissions when using heterogeneous computational resources, simulators, and simulation tasks. The object-oriented approach (1) provides flexibility to adapt to a variety of neuroscience simulators, (2) simplifies the use of heterogeneous computational resources, from desktops to super computer clusters, and (3) improves tracking of simulator/simulation evolution. We implemented NeuroManager in MATLAB, a widely used engineering and scientific language, for its signal and image processing tools, prevalence in electrophysiology analysis, and increasing use in college Biology education. To design and develop NeuroManager we analyzed the workflow of simulation submission for a variety of simulators, operating systems, and computational resources, including the handling of input parameters, data, models, results, and analyses. This resulted in 22 stages of simulation submission workflow. The software incorporates progress notification, automatic organization, labeling, and time-stamping of data and results, and integrated access to MATLAB's analysis and visualization tools. NeuroManager provides users with the tools to automate daily tasks, and assists principal investigators in tracking and recreating the evolution of research projects performed by multiple people. Overall, NeuroManager provides the infrastructure needed to improve workflow, manage multiple simultaneous simulations, and maintain provenance of the potentially large amounts of data produced during the course of a research project. PMID:26528175

  3. NeuroManager: a workflow analysis based simulation management engine for computational neuroscience.

    PubMed

    Stockton, David B; Santamaria, Fidel

    2015-01-01

    We developed NeuroManager, an object-oriented simulation management software engine for computational neuroscience. NeuroManager automates the workflow of simulation job submissions when using heterogeneous computational resources, simulators, and simulation tasks. The object-oriented approach (1) provides flexibility to adapt to a variety of neuroscience simulators, (2) simplifies the use of heterogeneous computational resources, from desktops to super computer clusters, and (3) improves tracking of simulator/simulation evolution. We implemented NeuroManager in MATLAB, a widely used engineering and scientific language, for its signal and image processing tools, prevalence in electrophysiology analysis, and increasing use in college Biology education. To design and develop NeuroManager we analyzed the workflow of simulation submission for a variety of simulators, operating systems, and computational resources, including the handling of input parameters, data, models, results, and analyses. This resulted in 22 stages of simulation submission workflow. The software incorporates progress notification, automatic organization, labeling, and time-stamping of data and results, and integrated access to MATLAB's analysis and visualization tools. NeuroManager provides users with the tools to automate daily tasks, and assists principal investigators in tracking and recreating the evolution of research projects performed by multiple people. Overall, NeuroManager provides the infrastructure needed to improve workflow, manage multiple simultaneous simulations, and maintain provenance of the potentially large amounts of data produced during the course of a research project.

  4. Computer-assisted cartography: an overview.

    USGS Publications Warehouse

    Guptill, S.C.; Starr, L.E.

    1984-01-01

    An assessment of the current status of computer-assisted cartography, in part, is biased by one's view of the cartographic process as a whole. From a traditional viewpoint we are concerned about automating the mapping process; from a progressive viewpoint we are concerned about using the tools of computer science to convey spatial information. On the surface these viewpoints appear to be in opposition. However, it is postulated that in the final analysis, they face the same goal. This overview uses the perspectives from two viewpoints to depict the current state of computer-assisted cartography and speculate on future goals, trends, and challenges.-Authors

  5. GPCALMA: A Tool For Mammography With A GRID-Connected Distributed Database

    NASA Astrophysics Data System (ADS)

    Bottigli, U.; Cerello, P.; Cheran, S.; Delogu, P.; Fantacci, M. E.; Fauci, F.; Golosio, B.; Lauria, A.; Lopez Torres, E.; Magro, R.; Masala, G. L.; Oliva, P.; Palmiero, R.; Raso, G.; Retico, A.; Stumbo, S.; Tangaro, S.

    2003-09-01

    The GPCALMA (Grid Platform for Computer Assisted Library for MAmmography) collaboration involves several departments of physics, INFN (National Institute of Nuclear Physics) sections, and italian hospitals. The aim of this collaboration is developing a tool that can help radiologists in early detection of breast cancer. GPCALMA has built a large distributed database of digitised mammographic images (about 5500 images corresponding to 1650 patients) and developed a CAD (Computer Aided Detection) software which is integrated in a station that can also be used to acquire new images, as archive and to perform statistical analysis. The images (18×24 cm2, digitised by a CCD linear scanner with a 85 μm pitch and 4096 gray levels) are completely described: pathological ones have a consistent characterization with radiologist's diagnosis and histological data, non pathological ones correspond to patients with a follow up at least three years. The distributed database is realized throught the connection of all the hospitals and research centers in GRID tecnology. In each hospital local patients digital images are stored in the local database. Using GRID connection, GPCALMA will allow each node to work on distributed database data as well as local database data. Using its database the GPCALMA tools perform several analysis. A texture analysis, i.e. an automated classification on adipose, dense or glandular texture, can be provided by the system. GPCALMA software also allows classification of pathological features, in particular massive lesions (both opacities and spiculated lesions) analysis and microcalcification clusters analysis. The detection of pathological features is made using neural network software that provides a selection of areas showing a given "suspicion level" of lesion occurrence. The performance of the GPCALMA system will be presented in terms of the ROC (Receiver Operating Characteristic) curves. The results of GPCALMA system as "second reader" will also be presented.

  6. Diagnostic Performance of a Rapid Magnetic Resonance Imaging Method of Measuring Hepatic Steatosis

    PubMed Central

    House, Michael J.; Gan, Eng K.; Adams, Leon A.; Ayonrinde, Oyekoya T.; Bangma, Sander J.; Bhathal, Prithi S.; Olynyk, John K.; St. Pierre, Tim G.

    2013-01-01

    Objectives Hepatic steatosis is associated with an increased risk of developing serious liver disease and other clinical sequelae of the metabolic syndrome. However, visual estimates of steatosis from histological sections of biopsy samples are subjective and reliant on an invasive procedure with associated risks. The aim of this study was to test the ability of a rapid, routinely available, magnetic resonance imaging (MRI) method to diagnose clinically relevant grades of hepatic steatosis in a cohort of patients with diverse liver diseases. Materials and Methods Fifty-nine patients with a range of liver diseases underwent liver biopsy and MRI. Hepatic steatosis was quantified firstly using an opposed-phase, in-phase gradient echo, single breath-hold MRI methodology and secondly, using liver biopsy with visual estimation by a histopathologist and by computer-assisted morphometric image analysis. The area under the receiver operating characteristic (ROC) curve was used to assess the diagnostic performance of the MRI method against the biopsy observations. Results The MRI approach had high sensitivity and specificity at all hepatic steatosis thresholds. Areas under ROC curves were 0.962, 0.993, and 0.972 at thresholds of 5%, 33%, and 66% liver fat, respectively. MRI measurements were strongly associated with visual (r2 = 0.83) and computer-assisted morphometric (r2 = 0.84) estimates of hepatic steatosis from histological specimens. Conclusions This MRI approach, using a conventional, rapid, gradient echo method, has high sensitivity and specificity for diagnosing liver fat at all grades of steatosis in a cohort with a range of liver diseases. PMID:23555650

  7. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique.

    PubMed

    Kotani, Yoshihisa; Abumi, Kuniyoshi; Ito, Manabu; Takahata, Masahiko; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio

    2007-06-15

    The accuracy of pedicle screw placement was evaluated in posterior scoliosis surgeries with or without the use of computer-assisted surgical techniques. In this retrospective cohort study, the pedicle screw placement accuracy in posterior scoliosis surgery was compared between conventional fluoroscopic and computer-assisted surgical techniques. There has been no study systemically analyzing the perforation pattern and comparative accuracy of pedicle screw placement in posterior scoliosis surgery. The 45 patients who received posterior correction surgeries were divided into 2 groups: Group C, manual control (25 patients); and Group N, navigation surgery (20 patients). The average Cobb angles were 73.7 degrees and 73.1 degrees before surgery in Group C and Group N, respectively. Using CT images, vertebral rotation, pedicle axes as measured to anteroposterior sacral axis and vertebral axis, and insertion angle error were measured. In perforation cases, the angular tendency, insertion point, and length abnormality were evaluated. The perforation was observed in 11% of Group C and 1.8% in Group N. In Group C, medial perforations of left screws were demonstrated in 8 of 9 perforated screws and 55% were distributed either in L1 or T12. The perforation consistently occurred in pedicles in which those axes approached anteroposterior sacral axis within 5 degrees . The average insertion errors were 8.4 degrees and 5.0 degrees in Group C and Group N, respectively, which were significantly different (P < 0.02). The medial perforation in Group C occurred around L1, especially when pedicle axis approached anteroposterior sacral axis. This consistent tendency was considered as the limitation of fluoroscopic screw insertion in which horizontal vertebral image was not visible. The use of surgical navigation system successfully reduced the perforation rate and insertion angle errors, demonstrating the clear advantage in safe and accurate pedicle screw placement of scoliosis surgery.

  8. Utilization of Solar Dynamics Observatory space weather digital image data for comparative analysis with application to Baryon Oscillation Spectroscopic Survey

    NASA Astrophysics Data System (ADS)

    Shekoyan, V.; Dehipawala, S.; Liu, Ernest; Tulsee, Vivek; Armendariz, R.; Tremberger, G.; Holden, T.; Marchese, P.; Cheung, T.

    2012-10-01

    Digital solar image data is available to users with access to standard, mass-market software. Many scientific projects utilize the Flexible Image Transport System (FITS) format, which requires specialized software typically used in astrophysical research. Data in the FITS format includes photometric and spatial calibration information, which may not be useful to researchers working with self-calibrated, comparative approaches. This project examines the advantages of using mass-market software with readily downloadable image data from the Solar Dynamics Observatory for comparative analysis over with the use of specialized software capable of reading data in the FITS format. Comparative analyses of brightness statistics that describe the solar disk in the study of magnetic energy using algorithms included in mass-market software have been shown to give results similar to analyses using FITS data. The entanglement of magnetic energy associated with solar eruptions, as well as the development of such eruptions, has been characterized successfully using mass-market software. The proposed algorithm would help to establish a publicly accessible, computing network that could assist in exploratory studies of all FITS data. The advances in computer, cell phone and tablet technology could incorporate such an approach readily for the enhancement of high school and first-year college space weather education on a global scale. Application to ground based data such as that contained in the Baryon Oscillation Spectroscopic Survey is discussed.

  9. Variogram methods for texture classification of atherosclerotic plaque ultrasound images

    NASA Astrophysics Data System (ADS)

    Jeromin, Oliver M.; Pattichis, Marios S.; Pattichis, Constantinos; Kyriacou, Efthyvoulos; Nicolaides, Andrew

    2006-03-01

    Stroke is the third leading cause of death in the western world and the major cause of disability in adults. The type and stenosis of extracranial carotid artery disease is often responsible for ischemic strokes, transient ischemic attacks (TIAs) or amaurosis fugax (AF). The identification and grading of stenosis can be done using gray scale ultrasound scans. The appearance of B-scan pictures containing various granular structures makes the use of texture analysis techniques suitable for computer assisted tissue characterization purposes. The objective of this study is to investigate the usefulness of variogram analysis in the assessment of ultrasound plague morphology. The variogram estimates the variance of random fields, from arbitrary samples in space. We explore stationary random field models based on the variogram, which can be applied in ultrasound plaque imaging leading to a Computer Aided Diagnosis (CAD) system for the early detection of symptomatic atherosclerotic plaques. Non-parametric tests on the variogram coefficients show that the cofficients coming from symptomatic versus asymptomatic plaques come from distinct distributions. Furthermore, we show significant improvement in class separation, when a log point-transformation is applied to the images, prior to variogram estimation. Model fitting using least squares is explored for anisotropic variograms along specific directions. Comparative classification results, show that variogram coefficients can be used for the early detection of symptomatic cases, and also exhibit the largest class distances between symptomatic and asymptomatic plaque images, as compared to over 60 other texture features, used in the literature.

  10. Automated processing of label-free Raman microscope images of macrophage cells with standardized regression for high-throughput analysis.

    PubMed

    Milewski, Robert J; Kumagai, Yutaro; Fujita, Katsumasa; Standley, Daron M; Smith, Nicholas I

    2010-11-19

    Macrophages represent the front lines of our immune system; they recognize and engulf pathogens or foreign particles thus initiating the immune response. Imaging macrophages presents unique challenges, as most optical techniques require labeling or staining of the cellular compartments in order to resolve organelles, and such stains or labels have the potential to perturb the cell, particularly in cases where incomplete information exists regarding the precise cellular reaction under observation. Label-free imaging techniques such as Raman microscopy are thus valuable tools for studying the transformations that occur in immune cells upon activation, both on the molecular and organelle levels. Due to extremely low signal levels, however, Raman microscopy requires sophisticated image processing techniques for noise reduction and signal extraction. To date, efficient, automated algorithms for resolving sub-cellular features in noisy, multi-dimensional image sets have not been explored extensively. We show that hybrid z-score normalization and standard regression (Z-LSR) can highlight the spectral differences within the cell and provide image contrast dependent on spectral content. In contrast to typical Raman imaging processing methods using multivariate analysis, such as single value decomposition (SVD), our implementation of the Z-LSR method can operate nearly in real-time. In spite of its computational simplicity, Z-LSR can automatically remove background and bias in the signal, improve the resolution of spatially distributed spectral differences and enable sub-cellular features to be resolved in Raman microscopy images of mouse macrophage cells. Significantly, the Z-LSR processed images automatically exhibited subcellular architectures whereas SVD, in general, requires human assistance in selecting the components of interest. The computational efficiency of Z-LSR enables automated resolution of sub-cellular features in large Raman microscopy data sets without compromise in image quality or information loss in associated spectra. These results motivate further use of label free microscopy techniques in real-time imaging of live immune cells.

  11. Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery.

    PubMed

    Renkawitz, Tobias; Tingart, Markus; Grifka, Joachim; Sendtner, Ernst; Kalteis, Thomas

    2009-09-01

    This article outlines the scientific basis and a state-of-the-art application of computer-assisted orthopedic surgery in total hip arthroplasty (THA) and provides a future perspective on this technology. Computer-assisted orthopedic surgery in primary THA has the potential to couple 3D simulations with real-time evaluations of surgical performance, which has brought these developments from the research laboratory all the way to clinical use. Nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during THA. More recently, computer-assisted orthopedic surgery systems have opened a new frontier for accurate surgical practice in minimally invasive, tissue-preserving THA. The future generation of imageless navigation systems will switch from simple measurement tasks to real navigation tools. These software algorithms will consider the cup and stem as components of a coupled biomechanical system, navigating the orthopedic surgeon to find an optimized complementary component orientation rather than target values intraoperatively, and are expected to have a high impact on clinical practice and postoperative functionality in modern THA.

  12. A knowledge based system for scientific data visualization

    NASA Technical Reports Server (NTRS)

    Senay, Hikmet; Ignatius, Eve

    1992-01-01

    A knowledge-based system, called visualization tool assistant (VISTA), which was developed to assist scientists in the design of scientific data visualization techniques, is described. The system derives its knowledge from several sources which provide information about data characteristics, visualization primitives, and effective visual perception. The design methodology employed by the system is based on a sequence of transformations which decomposes a data set into a set of data partitions, maps this set of partitions to visualization primitives, and combines these primitives into a composite visualization technique design. Although the primary function of the system is to generate an effective visualization technique design for a given data set by using principles of visual perception the system also allows users to interactively modify the design, and renders the resulting image using a variety of rendering algorithms. The current version of the system primarily supports visualization techniques having applicability in earth and space sciences, although it may easily be extended to include other techniques useful in other disciplines such as computational fluid dynamics, finite-element analysis and medical imaging.

  13. Computer-assisted spinal osteotomy: a technical note and report of four cases.

    PubMed

    Fujibayashi, Shunsuke; Neo, Masashi; Takemoto, Mitsuru; Ota, Masato; Nakayama, Tomitaka; Toguchida, Junya; Nakamura, Takashi

    2010-08-15

    A report of 4 cases of spinal osteotomy performed under the guidance of a computer-assisted navigation system and a technical note about the use of the navigation system for spinal osteotomy. To document the surgical technique and usefulness of computer-assisted surgery for spinal osteotomy. A computer-assisted navigation system provides accurate 3-dimensional (3D) real-time surgical information during the operation. Although there are many reports on the accuracy and usefulness of a navigation system for pedicle screw placement, there are few reports on the application for spinal osteotomy. We report on 4 complex cases including 3 solitary malignant spinal tumors and 1 spinal kyphotic deformity of ankylosing spondylitis, which were treated surgically using a computer-assisted spinal osteotomy. The surgical technique and postoperative clinical and radiologic results are presented. 3D spinal osteotomy under the guidance of a computer-assisted navigation system was performed successfully in 4 patients. All malignant tumors were resected en bloc, and the spinal deformity was corrected precisely according to the preoperative plan. Pathologic analysis confirmed the en bloc resection without tumor exposure in the 3 patients with a spinal tumor. The use of a computer-assisted navigation system will help ensure the safety and efficacy of a complex 3D spinal osteotomy.

  14. Experimental validation of A-mode ultrasound acquisition system for computer assisted orthopaedic surgery

    NASA Astrophysics Data System (ADS)

    De Lorenzo, Danilo; De Momi, Elena; Beretta, Elisa; Cerveri, Pietro; Perona, Franco; Ferrigno, Giancarlo

    2009-02-01

    Computer Assisted Orthopaedic Surgery (CAOS) systems improve the results and the standardization of surgical interventions. Anatomical landmarks and bone surface detection is straightforward to either register the surgical space with the pre-operative imaging space and to compute biomechanical parameters for prosthesis alignment. Surface points acquisition increases the intervention invasiveness and can be influenced by the soft tissue layer interposition (7-15mm localization errors). This study is aimed at evaluating the accuracy of a custom-made A-mode ultrasound (US) system for non invasive detection of anatomical landmarks and surfaces. A-mode solutions eliminate the necessity of US images segmentation, offers real-time signal processing and requires less invasive equipment. The system consists in a single transducer US probe optically tracked, a pulser/receiver and an FPGA-based board, which is responsible for logic control command generation and for real-time signal processing and three custom-made board (signal acquisition, blanking and synchronization). We propose a new calibration method of the US system. The experimental validation was then performed measuring the length of known-shape polymethylmethacrylate boxes filled with pure water and acquiring bone surface points on a bovine bone phantom covered with soft-tissue mimicking materials. Measurement errors were computed through MR and CT images acquisitions of the phantom. Points acquisition on bone surface with the US system demonstrated lower errors (1.2mm) than standard pointer acquisition (4.2mm).

  15. Pre-operative segmentation of neck CT datasets for the planning of neck dissections

    NASA Astrophysics Data System (ADS)

    Cordes, Jeanette; Dornheim, Jana; Preim, Bernhard; Hertel, Ilka; Strauss, Gero

    2006-03-01

    For the pre-operative segmentation of CT neck datasets, we developed the software assistant NeckVision. The relevant anatomical structures for neck dissection planning can be segmented and the resulting patient-specific 3D-models are visualized afterwards in another software system for intervention planning. As a first step, we examined the appropriateness of elementary segmentation techniques based on gray values and contour information to extract the structures in the neck region from CT data. Region growing, interactive watershed transformation and live-wire are employed for segmentation of different target structures. It is also examined, which of the segmentation tasks can be automated. Based on this analysis, the software assistant NeckVision was developed to optimally support the workflow of image analysis for clinicians. The usability of NeckVision was tested within a first evaluation with four otorhinolaryngologists from the university hospital of Leipzig, four computer scientists from the university of Magdeburg and two laymen in both fields.

  16. Antecedent Knowledge and Intelligent Computer Assisted Instruction.

    ERIC Educational Resources Information Center

    Woodward, John P.; Carnine, Douglas W.

    1988-01-01

    The article reviews Intelligent Computer Assisted Instruction (ICAI), an area of artificial intelligence and notes its shortcomings for learning disabled students. It is suggested that emphasis on antecedent knowledge (important facts, concepts, rules, and/or strategies for the content area) and content analysis and design techniques would make…

  17. A Multidisciplinary Model for Development of Intelligent Computer-Assisted Instruction.

    ERIC Educational Resources Information Center

    Park, Ok-choon; Seidel, Robert J.

    1989-01-01

    Proposes a schematic multidisciplinary model to help developers of intelligent computer-assisted instruction (ICAI) identify the types of required expertise and integrate them into a system. Highlights include domain types and expertise; knowledge acquisition; task analysis; knowledge representation; student modeling; diagnosis of learning needs;…

  18. Cost-Benefit Analysis for ECIA Chapter 1 and State DPPF Programs Comparing Groups Receiving Regular Program Instruction and Groups Receiving Computer Assisted Instruction/Computer Management System (CAI/CMS). 1986-87.

    ERIC Educational Resources Information Center

    Chamberlain, Ed

    A cost benefit study was conducted to determine the effectiveness of a computer assisted instruction/computer management system (CAI/CMS) as an alternative to conventional methods of teaching reading within Chapter 1 and DPPF funded programs of the Columbus (Ohio) Public Schools. The Chapter 1 funded Compensatory Language Experiences and Reading…

  19. The Burn Medical Assistant: Developing Machine Learning Algorithms to Aid in the Estimation of Burn Wound Size

    DTIC Science & Technology

    2017-10-01

    hypothesis that a computer machine learning algorithm can analyze and classify burn injures using multispectral imaging within 5% of an expert clinician...morbidity. In response to these challenges, the USAISR developed and obtained FDA 510(k) clearance of the Burn Navigator™, a computer decision support... computer decision support software (CDSS), can significantly change the CDSS algorithm’s recommendations and thus the total fluid administered to a

  20. An information gathering system for medical image inspection

    NASA Astrophysics Data System (ADS)

    Lee, Young-Jin; Bajcsy, Peter

    2005-04-01

    We present an information gathering system for medical image inspection that consists of software tools for capturing computer-centric and human-centric information. Computer-centric information includes (1) static annotations, such as (a) image drawings enclosing any selected area, a set of areas with similar colors, a set of salient points, and (b) textual descriptions associated with either image drawings or links between pairs of image drawings, and (2) dynamic (or temporal) information, such as mouse movements, zoom level changes, image panning and frame selections from an image stack. Human-centric information is represented by video and audio signals that are acquired by computer-mounted cameras and microphones. The short-term goal of the presented system is to facilitate learning of medical novices from medical experts, while the long-term goal is to data mine all information about image inspection for assisting in making diagnoses. In this work, we built basic software functionality for gathering computer-centric and human-centric information of the aforementioned variables. Next, we developed the information playback capabilities of all gathered information for educational purposes. Finally, we prototyped text-based and image template-based search engines to retrieve information from recorded annotations, for example, (a) find all annotations containing the word "blood vessels", or (b) search for similar areas to a selected image area. The information gathering system for medical image inspection reported here has been tested with images from the Histology Atlas database.

  1. Computed intraoperative navigation guidance--a preliminary report on a new technique.

    PubMed

    Enislidis, G; Wagner, A; Ploder, O; Ewers, R

    1997-08-01

    To assess the value of a computer-assisted three-dimensional guidance system (Virtual Patient System) in maxillofacial operations. Laboratory and open clinical study. Teaching Hospital, Austria. 6 patients undergoing various procedures including removal of foreign body (n=3) and biopsy, maxillary advancement, and insertion of implants (n=1 each). Storage of computed tomographic (CT) pictures on an optical disc, and imposition of intraoperative video images on to these. The resulting display is shown to the surgeon on a micromonitor in his head-up display for guidance during the operations. To improve orientation during complex or minimally invasive maxillofacial procedures and to make such operations easier and less traumatic. Successful transferral of computed navigation technology into an operation room environment and positive evaluation of the method by the surgeons involved. Computer-assisted three-dimensional guidance systems have the potential for making complex or minimally invasive procedures easier to do, thereby reducing postoperative morbidity.

  2. Landsat analysis of the Yangjiatan tungsten district, Hunan Province, People's Republic of China

    USGS Publications Warehouse

    Carter, W.D.; Kiilsgaard, T.H.

    1983-01-01

    The Yangjiatan tungsten district at latitude 27??28??? N. and longitude 111??54???E. is located about 140 km southwest of the city of Changsha and 35 km northeast of the town of Shaoyang, southeast Hunan Province, People's Republic of China. The deposits, consisting largely of scheelite in veins (Wang, 1975), are contained in highly folded and faulted sedimentary rocks of Paleozoic, Mesozoic, and Cenozoic age intruded by granitic plutons that are circular in plan view. The major faults and folds trend in a northeasterly direction; whereas, the plutons are clustered in a more easterly trending band across the Landsat image. Landsat image E-2338-02202, acquired December 26, 1975, is number 470 in the "Landsat Image Atlas of the People's Republic of China" printed by the Publishing House of Geology in 1979. A computer-compatible tape of the image was analyzed and used as a demonstration project under a United Nations technical assistance program. Supervised classification of soils, rocks, and vegetation; band ratioing to detect limonite alteration; and edge enhancement were all conducted to demonstrate the flexibility and capability of interactive computer systems. Field evaluation of the results of this work will be conducted by colleagues of the Remote Sensing Center for Geology, Ministry of Geology, in China. ?? 1983.

  3. Segmentation of White Blood Cells From Microscopic Images Using a Novel Combination of K-Means Clustering and Modified Watershed Algorithm.

    PubMed

    Ghane, Narjes; Vard, Alireza; Talebi, Ardeshir; Nematollahy, Pardis

    2017-01-01

    Recognition of white blood cells (WBCs) is the first step to diagnose some particular diseases such as acquired immune deficiency syndrome, leukemia, and other blood-related diseases that are usually done by pathologists using an optical microscope. This process is time-consuming, extremely tedious, and expensive and needs experienced experts in this field. Thus, a computer-aided diagnosis system that assists pathologists in the diagnostic process can be so effective. Segmentation of WBCs is usually a first step in developing a computer-aided diagnosis system. The main purpose of this paper is to segment WBCs from microscopic images. For this purpose, we present a novel combination of thresholding, k-means clustering, and modified watershed algorithms in three stages including (1) segmentation of WBCs from a microscopic image, (2) extraction of nuclei from cell's image, and (3) separation of overlapping cells and nuclei. The evaluation results of the proposed method show that similarity measures, precision, and sensitivity respectively were 92.07, 96.07, and 94.30% for nucleus segmentation and 92.93, 97.41, and 93.78% for cell segmentation. In addition, statistical analysis presents high similarity between manual segmentation and the results obtained by the proposed method.

  4. Build a Robust Learning Feature Descriptor by Using a New Image Visualization Method for Indoor Scenario Recognition

    PubMed Central

    Wang, Xin; Deng, Zhongliang

    2017-01-01

    In order to recognize indoor scenarios, we extract image features for detecting objects, however, computers can make some unexpected mistakes. After visualizing the histogram of oriented gradient (HOG) features, we find that the world through the eyes of a computer is indeed different from human eyes, which assists researchers to see the reasons that cause a computer to make errors. Additionally, according to the visualization, we notice that the HOG features can obtain rich texture information. However, a large amount of background interference is also introduced. In order to enhance the robustness of the HOG feature, we propose an improved method for suppressing the background interference. On the basis of the original HOG feature, we introduce a principal component analysis (PCA) to extract the principal components of the image colour information. Then, a new hybrid feature descriptor, which is named HOG–PCA (HOGP), is made by deeply fusing these two features. Finally, the HOGP is compared to the state-of-the-art HOG feature descriptor in four scenes under different illumination. In the simulation and experimental tests, the qualitative and quantitative assessments indicate that the visualizing images of the HOGP feature are close to the observation results obtained by human eyes, which is better than the original HOG feature for object detection. Furthermore, the runtime of our proposed algorithm is hardly increased in comparison to the classic HOG feature. PMID:28677635

  5. External ocular hyperemia: a quantifiable indicator of spacecraft air quality.

    PubMed

    Ogle, J W; Cohen, K L

    1996-05-01

    Eye irritation consistently ranks as a top astronaut complaint but is difficult to measure. Exposure to internal air pollution hypothetically disrupts the eye's tear film, thereby exposing the crewmembers' conjunctivae to the irritating effects of the recirculated, contaminant-laden atmosphere of the space vehicle. Causes elude engineers and toxicologists, who report that measured irritants remain below established Spacecraft Maximum Allowable Concentrations. Lack of objective ocular endpoints stymies efforts to identify etiologies. Computers offer a practical means of analyzing ocular hyperemia in space. We use computer analysis to quantify redness and blood vessels of digitized images of bulbar conjunctivae in near real time. Custom software masks artifacts, lids and lashes for each photographic or telemedicine ocular image, Algorithms then generate semi-independent measurements of hyperemia. Computed difference scores between 34 pairs of images were compared with subjective difference scores as voted on by a panel of ophthalmology residents. Objective data were reliably extracted from ocular images and significantly correlated (r = 0.583, p < 0.05) with subjective scores. This ground-based methodology generates accurate and reliable ocular endpoint data without mass, volume, or power penalty. To assist in identifying and eliminating onboard ocular irritants, these objective data can be regressed against independent variables such as mission elapsed time, subjective astronaut complaints, levels of chemical and electromagnetic contaminants, nephthelometric and barothermal data. As missions lengthen, sensitive tools such as hyperemia quantification will become increasingly important for assessing and optimizing spacecraft environments.

  6. Ischemic stroke enhancement in computed tomography scans using a computational approach

    NASA Astrophysics Data System (ADS)

    Alves, Allan F. F.; Pavan, Ana L. M.; Jennane, Rachid; Miranda, José R. A.; Freitas, Carlos C. M.; Abdala, Nitamar; Pina, Diana R.

    2018-03-01

    In this work, a novel approach was proposed to enhance the visual perception of ischemic stroke in computed tomography scans. Through different image processing techniques, we enabled less experienced physicians, to reliably detect early signs of stroke. A set of 40 retrospective CT scans of patients were used, divided into two groups: 25 cases of acute ischemic stroke and 15 normal cases used as control group. All cases were obtained within 4 hours of symptoms onset. Our approach was based on the variational decomposition model and three different segmentation methods. A test determined observers' performance to correctly diagnose stroke cases. The Expectation Maximization method provided the best results among all observers. The overall sensitivity of the observer's analysis was 64% and increased to 79%. The overall specificity was 67% and increased to 78%. These results show the importance of a computational tool to assist neuroradiology decisions, especially in critical situations such as the diagnosis of ischemic stroke.

  7. Computer-Design Drawing for NASA 2020 Mars Rover

    NASA Image and Video Library

    2016-07-15

    NASA's 2020 Mars rover mission will go to a region of Mars thought to have offered favorable conditions long ago for microbial life, and the rover will search for signs of past life there. It will also collect and cache samples for potential return to Earth, for many types of laboratory analysis. As a pioneering step toward how humans on Mars will use the Red Planet's natural resources, the rover will extract oxygen from the Martian atmosphere. This 2016 image comes from computer-assisted-design work on the 2020 rover. The design leverages many successful features of NASA's Curiosity rover, which landed on Mars in 2012, but it adds new science instruments and a sampling system to carry out the new goals for the mission. http://photojournal.jpl.nasa.gov/catalog/PIA20759

  8. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography.

    PubMed

    Kim, Kwang Baek; Kim, Chang Won

    2015-01-01

    Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.

  9. Quantification of Hepatorenal Index for Computer-Aided Fatty Liver Classification with Self-Organizing Map and Fuzzy Stretching from Ultrasonography

    PubMed Central

    Kim, Kwang Baek

    2015-01-01

    Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future. PMID:26247023

  10. Cell type classifiers for breast cancer microscopic images based on fractal dimension texture analysis of image color layers.

    PubMed

    Jitaree, Sirinapa; Phinyomark, Angkoon; Boonyaphiphat, Pleumjit; Phukpattaranont, Pornchai

    2015-01-01

    Having a classifier of cell types in a breast cancer microscopic image (BCMI), obtained with immunohistochemical staining, is required as part of a computer-aided system that counts the cancer cells in such BCMI. Such quantitation by cell counting is very useful in supporting decisions and planning of the medical treatment of breast cancer. This study proposes and evaluates features based on texture analysis by fractal dimension (FD), for the classification of histological structures in a BCMI into either cancer cells or non-cancer cells. The cancer cells include positive cells (PC) and negative cells (NC), while the normal cells comprise stromal cells (SC) and lymphocyte cells (LC). The FD feature values were calculated with the box-counting method from binarized images, obtained by automatic thresholding with Otsu's method of the grayscale images for various color channels. A total of 12 color channels from four color spaces (RGB, CIE-L*a*b*, HSV, and YCbCr) were investigated, and the FD feature values from them were used with decision tree classifiers. The BCMI data consisted of 1,400, 1,200, and 800 images with pixel resolutions 128 × 128, 192 × 192, and 256 × 256, respectively. The best cross-validated classification accuracy was 93.87%, for distinguishing between cancer and non-cancer cells, obtained using the Cr color channel with window size 256. The results indicate that the proposed algorithm, based on fractal dimension features extracted from a color channel, performs well in the automatic classification of the histology in a BCMI. This might support accurate automatic cell counting in a computer-assisted system for breast cancer diagnosis. © Wiley Periodicals, Inc.

  11. Case-based lung image categorization and retrieval for interstitial lung diseases: clinical workflows.

    PubMed

    Depeursinge, Adrien; Vargas, Alejandro; Gaillard, Frédéric; Platon, Alexandra; Geissbuhler, Antoine; Poletti, Pierre-Alexandre; Müller, Henning

    2012-01-01

    Clinical workflows and user interfaces of image-based computer-aided diagnosis (CAD) for interstitial lung diseases in high-resolution computed tomography are introduced and discussed. Three use cases are implemented to assist students, radiologists, and physicians in the diagnosis workup of interstitial lung diseases. In a first step, the proposed system shows a three-dimensional map of categorized lung tissue patterns with quantification of the diseases based on texture analysis of the lung parenchyma. Then, based on the proportions of abnormal and normal lung tissue as well as clinical data of the patients, retrieval of similar cases is enabled using a multimodal distance aggregating content-based image retrieval (CBIR) and text-based information search. The global system leads to a hybrid detection-CBIR-based CAD, where detection-based and CBIR-based CAD show to be complementary both on the user's side and on the algorithmic side. The proposed approach is in accordance with the classical workflow of clinicians searching for similar cases in textbooks and personal collections. The developed system enables objective and customizable inter-case similarity assessment, and the performance measures obtained with a leave-one-patient-out cross-validation (LOPO CV) are representative of a clinical usage of the system.

  12. Flood damage assessment using computer-assisted analysis of color infrared photography

    USGS Publications Warehouse

    Anderson, William H.

    1978-01-01

    Use of digitized aerial photographs for flood damage assessment in agriculture is new and largely untested. However, under flooding circumstances similar to the 1975 Red River Valley flood, computer-assisted techniques can be extremely useful, especially if detailed crop damage estimates are needed within a relatively short period of time.Airphoto interpretation techniques, manual or computer-assisted, are not intended to replace conventional ground survey and sampling procedures. But their use should be considered a valuable addition to the tools currently available for assessing agricultural flood damage.

  13. Computer-assisted qualitative data analysis software.

    PubMed

    Cope, Diane G

    2014-05-01

    Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.

  14. Stereoscopic Vascular Models of the Head and Neck: A Computed Tomography Angiography Visualization

    ERIC Educational Resources Information Center

    Cui, Dongmei; Lynch, James C.; Smith, Andrew D.; Wilson, Timothy D.; Lehman, Michael N.

    2016-01-01

    Computer-assisted 3D models are used in some medical and allied health science schools; however, they are often limited to online use and 2D flat screen-based imaging. Few schools take advantage of 3D stereoscopic learning tools in anatomy education and clinically relevant anatomical variations when teaching anatomy. A new approach to teaching…

  15. Correcting Spellings in Second Language Learners' Computer-Assisted Collaborative Writing

    ERIC Educational Resources Information Center

    Musk, Nigel

    2016-01-01

    The present study uses multimodal conversation analysis to examine how pupils studying English as a foreign language make spelling corrections in real time while doing collaborative computer-assisted project work. Unlike most previous related investigations, this study focuses on the "process" rather than evaluating the final…

  16. Applications of Parsing Theory to Computer-Assisted Instruction.

    ERIC Educational Resources Information Center

    Markosian, Lawrence Z.; Ager, Tryg A.

    1983-01-01

    Applications of an LR-1 parsing algorithm to intelligent programs for computer assisted instruction in symbolic logic and foreign languages are discussed. The system has been adequately used for diverse instructional applications, including analysis of student input, generation of pattern drills, and modeling the student's understanding of the…

  17. New Window into the Human Body

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Michael Vannier, MD, a former NASA engineer, recognized the similarity between NASA's computerized image processing technology and nuclear magnetic resonance. With technical assistance from Kennedy Space Center, he developed a computer program for Mallinckrodt Institute of Radiology enabling Nuclear Magnetic Resonance (NMR) to scan body tissue for earlier diagnoses. Dr. Vannier feels that "satellite imaging" has opened a new window into the human body.

  18. Different computer-assisted sperm analysis (CASA) systems highly influence sperm motility parameters.

    PubMed

    Boryshpolets, S; Kowalski, R K; Dietrich, G J; Dzyuba, B; Ciereszko, A

    2013-10-15

    In this study, we examined different computer-assisted sperm analysis (CASA) systems (CRISMAS, Hobson Sperm Tracker, and Image J CASA) on the exact same video recordings to evaluate the differences in sperm motility parameters related to the specific CASA used. To cover a wide range of sperm motility parameters, we chose 12-second video recordings at 25 and 50 Hz frame rates after sperm motility activation using three taxonomically distinct fish species (sterlet: Acipenser ruthenus L.; common carp: Cyprinus carpio L.; and rainbow trout: Oncorhynchus mykiss Walbaum) that are characterized by essential differences in sperm behavior during motility. Systematically higher values of velocity and beat cross frequency (BCF) were observed in video recordings obtained at 50 Hz frame frequency compared with 25 Hz for all three systems. Motility parameters were affected by the CASA and species used for analyses. Image J and CRISMAS calculated higher curvilinear velocity (VCL) values for rainbow trout and common carp at 25 Hz frequency compared with the Hobson Sperm Tracker, whereas at 50 Hz, a significant difference was observed only for rainbow trout sperm recordings. No significant difference was observed between the CASA systems for sterlet sperm motility at 25 and 50 Hz. Additional analysis of 1-second segments taken at three time points (1, 6, and 12 seconds of the recording) revealed a dramatic decrease in common carp and rainbow trout sperm speed. The motility parameters of sterlet spermatozoa did not change significantly during the 12-second motility period and should be considered as a suitable model for longer motility analyses. Our results indicated that the CASA used can affect motility results even when the same motility recordings are used. These results could be critically altered by the recording quality, time of analysis, and frame rate of camera, and could result in erroneous conclusions. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Computer-Controlled Image Anaysis of Solid Propellant Combustion Holograms Using a Quantimet 720 and a PDP-11.

    DTIC Science & Technology

    1985-09-01

    TND 1 96 PIN11. L 4. c. j;. NAVAL POSTGRADUATE SCHOOL Monterey, California NOV 19 19853 THESIS COMPUTER-CONTROLLED IMAGE ANALYSIS OF SOLID PROPELLANT...Controlled Image Analysis of Master’s Thesis Solid Propellant Combustion Holograms September, 1985 Using a Quantimet 720 and a PDP-11 S. PERFORMING ORG...unlimited Computer-Controlled Image Analysis of Solid Propellant * - Combustion Holograms Using a Quantimet 720 and a PDP-11 by Marvin Philip Shook

  20. Assessing the activity of perianal Crohn's disease: comparison of clinical indices and computer-assisted anal ultrasound.

    PubMed

    Losco, Alessandra; Viganò, Chiara; Conte, Dario; Cesana, Bruno Mario; Basilisco, Guido

    2009-05-01

    Assessing perianal disease activity is important for the treatment and prognosis of Crohn's disease (CD) patients, but the diagnostic accuracy of the activity indices has not yet been established. The aim of this study was to determine the accuracy and agreement of the Fistula Drainage Assessment (FDA), Perianal Disease Activity Index (PDAI), and computer-assisted anal ultrasound imaging (AUS). Sixty-two consecutive patients with CD and perianal fistulae underwent clinical, FDA, PDAI, and AUS evaluation. Perianal disease was considered active in the presence of visible fistula drainage and/or signs of local inflammation (induration and pain at digital compression) upon clinical examination. The AUS images were analyzed by calculating the mean gray-scale tone of the lesion. The PDAI and gray-scale tone values discriminating active and inactive perianal disease were defined using receiver operating characteristics statistics. Perianal disease was active in 46 patients. The accuracy of the FDA was 87% (confidence interval [CI]: 76%-94%). A PDAI of >4 and a mean gray-scale tone value of 117 maximized sensitivity and specificity; their diagnostic accuracy was, respectively, 87% (CI: 76%-94%) and 81% (CI: 69%-90%). The agreement of the 3 evaluations was fair to moderate. The addition of AUS to the PDAI or FDA increased their diagnostic accuracy to respectively 95% and 98%. The diagnostic accuracy of the FDA, PDAI, and computer-assisted AUS imaging was good in assessing perianal disease activity in patients with CD. The agreement between the techniques was fair to moderate. Overall accuracy can be increased by combining the FDA or PDAI with AUS.

  1. Computer algorithms and applications used to assist the evaluation and treatment of adolescent idiopathic scoliosis: a review of published articles 2000-2009.

    PubMed

    Phan, Philippe; Mezghani, Neila; Aubin, Carl-Éric; de Guise, Jacques A; Labelle, Hubert

    2011-07-01

    Adolescent idiopathic scoliosis (AIS) is a complex spinal deformity whose assessment and treatment present many challenges. Computer applications have been developed to assist clinicians. A literature review on computer applications used in AIS evaluation and treatment has been undertaken. The algorithms used, their accuracy and clinical usability were analyzed. Computer applications have been used to create new classifications for AIS based on 2D and 3D features, assess scoliosis severity or risk of progression and assist bracing and surgical treatment. It was found that classification accuracy could be improved using computer algorithms that AIS patient follow-up and screening could be done using surface topography thereby limiting radiation and that bracing and surgical treatment could be optimized using simulations. Yet few computer applications are routinely used in clinics. With the development of 3D imaging and databases, huge amounts of clinical and geometrical data need to be taken into consideration when researching and managing AIS. Computer applications based on advanced algorithms will be able to handle tasks that could otherwise not be done which can possibly improve AIS patients' management. Clinically oriented applications and evidence that they can improve current care will be required for their integration in the clinical setting.

  2. Elementary and Advanced Computer Projects for the Physics Classroom and Laboratory

    DTIC Science & Technology

    1992-12-01

    are SPF/PC, MS Word, n3, Symphony, Mathematics, and FORTRAN. The authors’ programs assist data analysis in particular laboratory experiments and make...assist data analysis in particular laboratory experiments and make use of the Monte Carlo and other numerical techniques in computer simulation and...the language of science and engineering in industry and government laboratories (alth..4h C is becoming a powerful competitor ). RM/FORTRAN (cost $400

  3. Effects of Computer Applications on Elementary School Students' Achievement: A Meta-Analysis of Students in Taiwan

    ERIC Educational Resources Information Center

    Liao, Yuen-kuang Cliff; Chang, Huei-wen; Chen, Yu-wen

    2008-01-01

    A meta-analysis was performed to synthesize existing research comparing the effects of computer applications (i.e., computer-assisted instruction, computer simulations, and Web-based learning) versus traditional instruction on elementary school students' achievement in Taiwan. Forty-eight studies were located from four sources, and their…

  4. Highlighting the medical applications of 3D printing in Egypt

    PubMed Central

    Abdelghany, Khaled; Hamza, Hosamuddin

    2015-01-01

    Computer-assisted designing/computer-assisted manufacturing (CAD/CAM) technology has enabled medical practitioners to tailor physical models in a patient and purpose-specific fashion. It allows the designing and manufacturing of templates, appliances and devices with a high range of accuracy using biocompatible materials. The technique, nevertheless, relies on digital scanning (e.g., using intraoral scanners) and/or digital imaging (e.g., CT and MRI). In developing countries, there are some technical and financial limitations of implementing such advanced tools as an essential portion of medical applications. This paper focuses on the surgical and dental use of 3D printing technology in Egypt as a developing country. PMID:26807414

  5. Crop-phenology and LANDSAT-based irrigated lands inventory in the high plains. [United States

    NASA Technical Reports Server (NTRS)

    Martinko, E. A. (Principal Investigator); Poracsky, J.; Kipp, E. R.; Krieger, H.

    1981-01-01

    Optimal LANDSAT image dates for 1980 were identified based on the weekly crop-weather reports for Colorado, New Mexico, South Dakota, Texas, Oklahoma, Kansas, Nebraska, and Wyoming. The 1979 agricultural statistics data were entered into computer files and a revised questionnaire was developed and mailed to ASCS county agents. A set of computer programs was developed to allow the preparation of computer-assisted graphic displays of much of the collected data.

  6. TheHiveDB image data management and analysis framework.

    PubMed

    Muehlboeck, J-Sebastian; Westman, Eric; Simmons, Andrew

    2014-01-06

    The hive database system (theHiveDB) is a web-based brain imaging database, collaboration, and activity system which has been designed as an imaging workflow management system capable of handling cross-sectional and longitudinal multi-center studies. It can be used to organize and integrate existing data from heterogeneous projects as well as data from ongoing studies. It has been conceived to guide and assist the researcher throughout the entire research process, integrating all relevant types of data across modalities (e.g., brain imaging, clinical, and genetic data). TheHiveDB is a modern activity and resource management system capable of scheduling image processing on both private compute resources and the cloud. The activity component supports common image archival and management tasks as well as established pipeline processing (e.g., Freesurfer for extraction of scalar measures from magnetic resonance images). Furthermore, via theHiveDB activity system algorithm developers may grant access to virtual machines hosting versioned releases of their tools to collaborators and the imaging community. The application of theHiveDB is illustrated with a brief use case based on organizing, processing, and analyzing data from the publically available Alzheimer Disease Neuroimaging Initiative.

  7. Does non-echo-planar diffusion-weighted magnetic resonance imaging have a role in assisting the clinical diagnosis of cholesteatoma in selected cases?

    PubMed

    Nash, R; Lingam, R K; Chandrasekharan, D; Singh, A

    2018-03-01

    To determine the diagnostic performance of diffusion-weighted magnetic resonance imaging in the assessment of patients with suspected, but not clinically evident, cholesteatoma. A retrospective analysis of a prospectively collected database of non-echo-planar diffusion-weighted magnetic resonance imaging studies (using a half-Fourier single-shot turbo-spin echo sequence) was conducted. Clinical records were retrospectively reviewed to determine indications for imaging and operative findings. Seventy-eight investigations in 74 patients with suspected cholesteatoma aged 5.7-79.2 years (mean, 41.7 years) were identified. Operative confirmation was available in 44 ears. Diagnostic accuracy of the imaging technique was calculated using operative findings as a 'gold standard'. Sensitivity of the investigation was examined via comparison with clinically evident cholesteatoma. The accuracy of diffusion-weighted magnetic resonance imaging in assessment of suspected cholesteatoma was 63.6 per cent. The imaging technique was significantly less accurate in assessment of suspected cholesteatoma than clinically evident disease (p < 0.001). Computed tomography and diffusion-weighted magnetic resonance imaging may be complementary in assessment of suspected cholesteatoma, but should be used with caution, and clinical judgement is paramount.

  8. TheHiveDB image data management and analysis framework

    PubMed Central

    Muehlboeck, J-Sebastian; Westman, Eric; Simmons, Andrew

    2014-01-01

    The hive database system (theHiveDB) is a web-based brain imaging database, collaboration, and activity system which has been designed as an imaging workflow management system capable of handling cross-sectional and longitudinal multi-center studies. It can be used to organize and integrate existing data from heterogeneous projects as well as data from ongoing studies. It has been conceived to guide and assist the researcher throughout the entire research process, integrating all relevant types of data across modalities (e.g., brain imaging, clinical, and genetic data). TheHiveDB is a modern activity and resource management system capable of scheduling image processing on both private compute resources and the cloud. The activity component supports common image archival and management tasks as well as established pipeline processing (e.g., Freesurfer for extraction of scalar measures from magnetic resonance images). Furthermore, via theHiveDB activity system algorithm developers may grant access to virtual machines hosting versioned releases of their tools to collaborators and the imaging community. The application of theHiveDB is illustrated with a brief use case based on organizing, processing, and analyzing data from the publically available Alzheimer Disease Neuroimaging Initiative. PMID:24432000

  9. Information granules in image histogram analysis.

    PubMed

    Wieclawek, Wojciech

    2018-04-01

    A concept of granular computing employed in intensity-based image enhancement is discussed. First, a weighted granular computing idea is introduced. Then, the implementation of this term in the image processing area is presented. Finally, multidimensional granular histogram analysis is introduced. The proposed approach is dedicated to digital images, especially to medical images acquired by Computed Tomography (CT). As the histogram equalization approach, this method is based on image histogram analysis. Yet, unlike the histogram equalization technique, it works on a selected range of the pixel intensity and is controlled by two parameters. Performance is tested on anonymous clinical CT series. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A robust automated left ventricle region of interest localization technique using a cardiac cine MRI atlas

    NASA Astrophysics Data System (ADS)

    Ben-Zikri, Yehuda Kfir; Linte, Cristian A.

    2016-03-01

    Region of interest detection is a precursor to many medical image processing and analysis applications, including segmentation, registration and other image manipulation techniques. The optimal region of interest is often selected manually, based on empirical knowledge and features of the image dataset. However, if inconsistently identified, the selected region of interest may greatly affect the subsequent image analysis or interpretation steps, in turn leading to incomplete assessment during computer-aided diagnosis or incomplete visualization or identification of the surgical targets, if employed in the context of pre-procedural planning or image-guided interventions. Therefore, the need for robust, accurate and computationally efficient region of interest localization techniques is prevalent in many modern computer-assisted diagnosis and therapy applications. Here we propose a fully automated, robust, a priori learning-based approach that provides reliable estimates of the left and right ventricle features from cine cardiac MR images. The proposed approach leverages the temporal frame-to-frame motion extracted across a range of short axis left ventricle slice images with small training set generated from les than 10% of the population. This approach is based on histogram of oriented gradients features weighted by local intensities to first identify an initial region of interest depicting the left and right ventricles that exhibits the greatest extent of cardiac motion. This region is correlated with the homologous region that belongs to the training dataset that best matches the test image using feature vector correlation techniques. Lastly, the optimal left ventricle region of interest of the test image is identified based on the correlation of known ground truth segmentations associated with the training dataset deemed closest to the test image. The proposed approach was tested on a population of 100 patient datasets and was validated against the ground truth region of interest of the test images manually annotated by experts. This tool successfully identified a mask around the LV and RV and furthermore the minimal region of interest around the LV that fully enclosed the left ventricle from all testing datasets, yielding a 98% overlap with their corresponding ground truth. The achieved mean absolute distance error between the two contours that normalized by the radius of the ground truth is 0.20 +/- 0.09.

  11. IMAGES: An interactive image processing system

    NASA Technical Reports Server (NTRS)

    Jensen, J. R.

    1981-01-01

    The IMAGES interactive image processing system was created specifically for undergraduate remote sensing education in geography. The system is interactive, relatively inexpensive to operate, almost hardware independent, and responsive to numerous users at one time in a time-sharing mode. Most important, it provides a medium whereby theoretical remote sensing principles discussed in lecture may be reinforced in laboratory as students perform computer-assisted image processing. In addition to its use in academic and short course environments, the system has also been used extensively to conduct basic image processing research. The flow of information through the system is discussed including an overview of the programs.

  12. System and method for object localization

    NASA Technical Reports Server (NTRS)

    Kelly, Alonzo J. (Inventor); Zhong, Yu (Inventor)

    2005-01-01

    A computer-assisted method for localizing a rack, including sensing an image of the rack, detecting line segments in the sensed image, recognizing a candidate arrangement of line segments in the sensed image indicative of a predetermined feature of the rack, generating a matrix of correspondence between the candidate arrangement of line segments and an expected position and orientation of the predetermined feature of the rack, and estimating a position and orientation of the rack based on the matrix of correspondence.

  13. Normalized gradient fields cross-correlation for automated detection of prostate in magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Fotin, Sergei V.; Yin, Yin; Periaswamy, Senthil; Kunz, Justin; Haldankar, Hrishikesh; Muradyan, Naira; Cornud, François; Turkbey, Baris; Choyke, Peter L.

    2012-02-01

    Fully automated prostate segmentation helps to address several problems in prostate cancer diagnosis and treatment: it can assist in objective evaluation of multiparametric MR imagery, provides a prostate contour for MR-ultrasound (or CT) image fusion for computer-assisted image-guided biopsy or therapy planning, may facilitate reporting and enables direct prostate volume calculation. Among the challenges in automated analysis of MR images of the prostate are the variations of overall image intensities across scanners, the presence of nonuniform multiplicative bias field within scans and differences in acquisition setup. Furthermore, images acquired with the presence of an endorectal coil suffer from localized high-intensity artifacts at the posterior part of the prostate. In this work, a three-dimensional method for fast automated prostate detection based on normalized gradient fields cross-correlation, insensitive to intensity variations and coil-induced artifacts, is presented and evaluated. The components of the method, offline template learning and the localization algorithm, are described in detail. The method was validated on a dataset of 522 T2-weighted MR images acquired at the National Cancer Institute, USA that was split in two halves for development and testing. In addition, second dataset of 29 MR exams from Centre d'Imagerie Médicale Tourville, France were used to test the algorithm. The 95% confidence intervals for the mean Euclidean distance between automatically and manually identified prostate centroids were 4.06 +/- 0.33 mm and 3.10 +/- 0.43 mm for the first and second test datasets respectively. Moreover, the algorithm provided the centroid within the true prostate volume in 100% of images from both datasets. Obtained results demonstrate high utility of the detection method for a fully automated prostate segmentation.

  14. The use of computer imaging techniques to visualize cardiac muscle cells in three dimensions.

    PubMed

    Marino, T A; Cook, P N; Cook, L T; Dwyer, S J

    1980-11-01

    Atrial muscle cells and atrioventricular bundle cells were reconstructed using a computer-assisted three-dimensional reconstruction system. This reconstruction technique permitted these cells to be viewed from any direction. The cell surfaces were approximated using triangular tiles, and this optimization technique for cell reconstruction allowed for the computation of cell surface area and cell volume. A transparent mode is described which enables the investigator to examine internal cellular features such as the shape and location of the nucleus. In addition, more than one cell can be displayed simultaneously, and, therefore, spatial relationships are preserved and intercellular relationships viewed directly. The use of computer imaging techniques allows for a more complete collection of quantitative morphological data and also the visualization of the morphological information gathered.

  15. Combined Synchrotron X-ray Diffraction and Digital Image Correlation Technique for Measurement of Austenite Transformation with Strain in TRIP-assisted Steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poling, Whitney A.; Savic, Vesna; Hector, Louis G.

    2016-04-05

    The strain-induced, diffusionless shear transformation of retained austenite to martensite during straining of transformation induced plasticity (TRIP) assisted steels increases strain hardening and delays necking and fracture leading to exceptional ductility and strength, which are attractive for automotive applications. A novel technique that provides the retained austenite volume fraction variation with strain in TRIP-assisted steels with improved precision is presented. Digital images of the gauge section of tensile specimens were first recorded up to selected plastic strains with a stereo digital image correlation (DIC) system. The austenite volume fraction was measured by synchrotron X-ray diffraction from small squares cut frommore » the gage section. Strain fields in the squares were then computed by localizing the strain measurement to the corresponding region of a given square during DIC post-processing of the images recorded during tensile testing. Results obtained for a QP980 steel are used to study the influence of initial volume fraction of austenite and the austenite transformation with strain on tensile mechanical behavior.« less

  16. Computer-Assisted, Programmed Text, and Lecture Modes of Instruction in Three Medical Training Courses: Comparative Evaluation. Final Report.

    ERIC Educational Resources Information Center

    Deignan, Gerard M.; And Others

    This report contains a comparative analysis of the differential effectiveness of computer-assisted instruction (CAI), programmed instructional text (PIT), and lecture methods of instruction in three medical courses--Medical Laboratory, Radiology, and Dental. The summative evaluation includes (1) multiple regression analyses conducted to predict…

  17. Students' learning of clinical sonography: use of computer-assisted instruction and practical class.

    PubMed

    Wood, A K; Dadd, M J; Lublin, J R

    1996-08-01

    The application of information technology to teaching radiology will profoundly change the way learning is mediated to students. In this project, the integration of veterinary medical students' knowledge of sonography was promoted by a computer-assisted instruction program and a subsequent practical class. The computer-assisted instruction program emphasized the physical principles of clinical sonography and contained simulations and user-active experiments. In the practical class, the students used an actual sonographic machine for the first time and made images of a tissue-equivalent phantom. Students' responses to questionnaires were analyzed. On completing the overall project, 96% of the students said that they now understood sonographic concepts very or reasonably well, and 98% had become very or moderately interested in clinical sonography. The teaching and learning initiatives enhanced an integrated approach to learning, stimulated student interest and curiosity, improved understanding of sonographic principles, and contributed to an increased confidence and skill in using sonographic equipment.

  18. Strategies for the Segmentation of Subcutaneous Vascular Patterns in Thermographic Images

    NASA Astrophysics Data System (ADS)

    Chan, Eric K. Y.; Pearce, John A.

    1989-05-01

    Computer-assisted segmentation of vascular patterns in thermographic images provides the clinician with graphic outlines of thermally significant subcutaneous blood vessels. Segmentation strategies compared here consist of image smoothing protocols followed by thresholding and zero-crossing edge detectors. Median prefiltering followed by the Frei-Chen algorithm gave the most reproducible results, with an execution time of 143 seconds for 256 X 256 images. The Laplacian of Gaussian operator was not suitable due to streak artifacts in the thermographic imaging system. This computerized process may be adopted in a fast paced clinical environment to aid in the diagnosis and assessment of peripheral circulatory diseases, Raynaud's Disease3, phlebitis, varicose veins, as well as diseases of the autonomic nervous system. The same methodology may be applied to enhance the appearance of abnormal breast vascular patterns, and hence serve as an adjunct to mammography in the diagnosis of breast cancer. The automatically segmented vascular patterns, which have a hand drawn appearance, may also be used as a data reduction precursor to higher level pattern analysis and classification tasks.

  19. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    PubMed Central

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  20. Towards ubiquitous access of computer-assisted surgery systems.

    PubMed

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  1. Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.

    PubMed

    Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-04-01

    The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Computer-assisted surgery in the lower jaw: double surgical guide for immediately loaded implants in postextractive sites-technical notes and a case report.

    PubMed

    De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco

    2010-01-01

    Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.

  3. Crowdtruth validation: a new paradigm for validating algorithms that rely on image correspondences.

    PubMed

    Maier-Hein, Lena; Kondermann, Daniel; Roß, Tobias; Mersmann, Sven; Heim, Eric; Bodenstedt, Sebastian; Kenngott, Hannes Götz; Sanchez, Alexandro; Wagner, Martin; Preukschas, Anas; Wekerle, Anna-Laura; Helfert, Stefanie; März, Keno; Mehrabi, Arianeb; Speidel, Stefanie; Stock, Christian

    2015-08-01

    Feature tracking and 3D surface reconstruction are key enabling techniques to computer-assisted minimally invasive surgery. One of the major bottlenecks related to training and validation of new algorithms is the lack of large amounts of annotated images that fully capture the wide range of anatomical/scene variance in clinical practice. To address this issue, we propose a novel approach to obtaining large numbers of high-quality reference image annotations at low cost in an extremely short period of time. The concept is based on outsourcing the correspondence search to a crowd of anonymous users from an online community (crowdsourcing) and comprises four stages: (1) feature detection, (2) correspondence search via crowdsourcing, (3) merging multiple annotations per feature by fitting Gaussian finite mixture models, (4) outlier removal using the result of the clustering as input for a second annotation task. On average, 10,000 annotations were obtained within 24 h at a cost of $100. The annotation of the crowd after clustering and before outlier removal was of expert quality with a median distance of about 1 pixel to a publically available reference annotation. The threshold for the outlier removal task directly determines the maximum annotation error, but also the number of points removed. Our concept is a novel and effective method for fast, low-cost and highly accurate correspondence generation that could be adapted to various other applications related to large-scale data annotation in medical image computing and computer-assisted interventions.

  4. Nonsubsampled rotated complex wavelet transform (NSRCxWT) for medical image fusion related to clinical aspects in neurocysticercosis.

    PubMed

    Chavan, Satishkumar S; Mahajan, Abhishek; Talbar, Sanjay N; Desai, Subhash; Thakur, Meenakshi; D'cruz, Anil

    2017-02-01

    Neurocysticercosis (NCC) is a parasite infection caused by the tapeworm Taenia solium in its larvae stage which affects the central nervous system of the human body (a definite host). It results in the formation of multiple lesions in the brain at different locations during its various stages. During diagnosis of such symptomatic patients, these lesions can be better visualized using a feature based fusion of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). This paper presents a novel approach to Multimodality Medical Image Fusion (MMIF) used for the analysis of the lesions for the diagnostic purpose and post treatment review of NCC. The MMIF presented here is a technique of combining CT and MRI data of the same patient into a new slice using a Nonsubsampled Rotated Complex Wavelet Transform (NSRCxWT). The forward NSRCxWT is applied on both the source modalities separately to extract the complementary and the edge related features. These features are then combined to form a composite spectral plane using average and maximum value selection fusion rules. The inverse transformation on this composite plane results into a new, visually better, and enriched fused image. The proposed technique is tested on the pilot study data sets of patients infected with NCC. The quality of these fused images is measured using objective and subjective evaluation metrics. Objective evaluation is performed by estimating the fusion parameters like entropy, fusion factor, image quality index, edge quality measure, mean structural similarity index measure, etc. The fused images are also evaluated for their visual quality using subjective analysis with the help of three expert radiologists. The experimental results on 43 image data sets of 17 patients are promising and superior when compared with the state of the art wavelet based fusion algorithms. The proposed algorithm can be a part of computer-aided detection and diagnosis (CADD) system which assists the radiologists in clinical practices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Methyl green and nitrotetrazolium blue chloride co-expression in colon tissue: A hyperspectral microscopic imaging analysis

    NASA Astrophysics Data System (ADS)

    Li, Qingli; Liu, Hongying; Wang, Yiting; Sun, Zhen; Guo, Fangmin; Zhu, Jianzhong

    2014-12-01

    Histological observation of dual-stained colon sections is usually performed by visual observation under a light microscope, or by viewing on a computer screen with the assistance of image processing software in both research and clinical settings. These traditional methods are usually not sufficient to reliably differentiate spatially overlapping chromogens generated by different dyes. Hyperspectral microscopic imaging technology offers a solution for these constraints as the hyperspectral microscopic images contain information that allows differentiation between spatially co-located chromogens with similar but different spectra. In this paper, a hyperspectral microscopic imaging (HMI) system is used to identify methyl green and nitrotetrazolium blue chloride in dual-stained colon sections. Hyperspectral microscopic images are captured and the normalized score algorithm is proposed to identify the stains and generate the co-expression results. Experimental results show that the proposed normalized score algorithm can generate more accurate co-localization results than the spectral angle mapper algorithm. The hyperspectral microscopic imaging technology can enhance the visualization of dual-stained colon sections, improve the contrast and legibility of each stain using their spectral signatures, which is helpful for pathologist performing histological analyses.

  6. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera

    NASA Astrophysics Data System (ADS)

    Wang, Hongkai; Stout, David B.; Taschereau, Richard; Gu, Zheng; Vu, Nam T.; Prout, David L.; Chatziioannou, Arion F.

    2012-10-01

    This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.

  7. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera.

    PubMed

    Wang, Hongkai; Stout, David B; Taschereau, Richard; Gu, Zheng; Vu, Nam T; Prout, David L; Chatziioannou, Arion F

    2012-10-07

    This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.

  8. The relationship between computed tomography findings and the locations of perforated peptic ulcers: it may provide better information for gastrointestinal surgeons.

    PubMed

    Wang, Shang-Yu; Cheng, Chi-Tung; Liao, Chien-Hung; Fu, Chih-Yuan; Wong, Yon-Cheong; Chen, Huan-Wu; Ouyang, Chun-Hsiang; Kuo, I-Ming; Hsu, Yu-Pao; Yeh, Chun-Nan

    2016-10-01

    Computed tomography (CT) plays an important role in diagnosing gastrointestinal perforation. This study explored the relationship between CT findings and the locations of perforated peptic ulcers (PPUs), which may help further surgical planning. During a 34-month period, 175 patients had CT scans. We categorized those 175 patients into 2 groups: patients with and without a PPU at a difficult ulcer site for a laparoscopic approach. Both clinical data and the CT images were reviewed and analyzed. Based on the univariate analysis results, we conducted multivariate analyses of 3 factors: age, American Society of Anesthesiologists classification of 3 or more, and positive lesser sac image findings. The positive lesser sac findings in CT were the only independent factor that was correlated to the PPU site. Positive lesser sac CT findings may help to predict PPUs in sites where a laparoscopic approach might be difficult. Our study re-evaluates the additional value of CT scanning in diagnosing PPU, and the results may assist with surgical planning in clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Computer-aided diagnostics of screening mammography using content-based image retrieval

    NASA Astrophysics Data System (ADS)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  10. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  11. Transforming information for computer-aided instruction: using a Socratic Dialogue method to teach gross anatomy.

    PubMed Central

    Constantinou, P.; Daane, S.; Dev, P.

    1994-01-01

    Traditional teaching of anatomy can be a difficult process of rote memorization. Computers allow information presentation to be much more dynamic, and interactive; the same information can be presented in multiple organizations. Using this idea, we have implemented a new pedagogy for computer-assisted instruction in The Anatomy Lesson, an interactive digital teacher which uses a "Socratic Dialogue" metaphor, as well as a textbook-like approach, to facilitate conceptual learning in anatomy. Images Figure 1 PMID:7949881

  12. Modeling the pharyngeal pressure during adult nasal high flow therapy.

    PubMed

    Kumar, Haribalan; Spence, Callum J T; Tawhai, Merryn H

    2015-12-01

    Subjects receiving nasal high flow (NHF) via wide-bore nasal cannula may experience different levels of positive pressure depending on the individual response to NHF. In this study, airflow in the nasal airway during NHF-assisted breathing is simulated and nasopharyngeal airway pressure numerically computed, to determine whether the relationship between NHF and pressure can be described by a simple equation. Two geometric models are used for analysis. In the first, 3D airway geometry is reconstructed from computed tomography images of an adult nasal airway. For the second, a simplified geometric model is derived that has the same cross-sectional area as the complex model, but is more readily amenable to analysis. Peak airway pressure is correlated as a function of nasal valve area, nostril area and cannula flow rate, for NHF rates of 20, 40 and 60 L/min. Results show that airway pressure is related by a power law to NHF rate, valve area, and nostril area. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Investigation into diagnostic agreement using automated computer-assisted histopathology pattern recognition image analysis.

    PubMed

    Webster, Joshua D; Michalowski, Aleksandra M; Dwyer, Jennifer E; Corps, Kara N; Wei, Bih-Rong; Juopperi, Tarja; Hoover, Shelley B; Simpson, R Mark

    2012-01-01

    The extent to which histopathology pattern recognition image analysis (PRIA) agrees with microscopic assessment has not been established. Thus, a commercial PRIA platform was evaluated in two applications using whole-slide images. Substantial agreement, lacking significant constant or proportional errors, between PRIA and manual morphometric image segmentation was obtained for pulmonary metastatic cancer areas (Passing/Bablok regression). Bland-Altman analysis indicated heteroscedastic measurements and tendency toward increasing variance with increasing tumor burden, but no significant trend in mean bias. The average between-methods percent tumor content difference was -0.64. Analysis of between-methods measurement differences relative to the percent tumor magnitude revealed that method disagreement had an impact primarily in the smallest measurements (tumor burden <3%). Regression-based 95% limits of agreement indicated substantial agreement for method interchangeability. Repeated measures revealed concordance correlation of >0.988, indicating high reproducibility for both methods, yet PRIA reproducibility was superior (C.V.: PRIA = 7.4, manual = 17.1). Evaluation of PRIA on morphologically complex teratomas led to diagnostic agreement with pathologist assessments of pluripotency on subsets of teratomas. Accommodation of the diversity of teratoma histologic features frequently resulted in detrimental trade-offs, increasing PRIA error elsewhere in images. PRIA error was nonrandom and influenced by variations in histomorphology. File-size limitations encountered while training algorithms and consequences of spectral image processing dominance contributed to diagnostic inaccuracies experienced for some teratomas. PRIA appeared better suited for tissues with limited phenotypic diversity. Technical improvements may enhance diagnostic agreement, and consistent pathologist input will benefit further development and application of PRIA.

  14. Google glass based immunochromatographic diagnostic test analysis

    NASA Astrophysics Data System (ADS)

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2015-03-01

    Integration of optical imagers and sensors into recently emerging wearable computational devices allows for simpler and more intuitive methods of integrating biomedical imaging and medical diagnostics tasks into existing infrastructures. Here we demonstrate the ability of one such device, the Google Glass, to perform qualitative and quantitative analysis of immunochromatographic rapid diagnostic tests (RDTs) using a voice-commandable hands-free software-only interface, as an alternative to larger and more bulky desktop or handheld units. Using the built-in camera of Glass to image one or more RDTs (labeled with Quick Response (QR) codes), our Glass software application uploads the captured image and related information (e.g., user name, GPS, etc.) to our servers for remote analysis and storage. After digital analysis of the RDT images, the results are transmitted back to the originating Glass device, and made available through a website in geospatial and tabular representations. We tested this system on qualitative human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) RDTs. For qualitative HIV tests, we demonstrate successful detection and labeling (i.e., yes/no decisions) for up to 6-fold dilution of HIV samples. For quantitative measurements, we activated and imaged PSA concentrations ranging from 0 to 200 ng/mL and generated calibration curves relating the RDT line intensity values to PSA concentration. By providing automated digitization of both qualitative and quantitative test results, this wearable colorimetric diagnostic test reader platform on Google Glass can reduce operator errors caused by poor training, provide real-time spatiotemporal mapping of test results, and assist with remote monitoring of various biomedical conditions.

  15. Fusion Imaging: A Novel Staging Modality in Testis Cancer

    PubMed Central

    Sterbis, Joseph R.; Rice, Kevin R.; Javitt, Marcia C.; Schenkman, Noah S.; Brassell, Stephen A.

    2010-01-01

    Objective: Computed tomography and chest radiographs provide the standard imaging for staging, treatment, and surveillance of testicular germ cell neoplasms. Positron emission tomography has recently been utilized for staging, but is somewhat limited in its ability to provide anatomic localization. Fusion imaging combines the metabolic information provided by positron emission tomography with the anatomic precision of computed tomography. To the best of our knowledge, this represents the first study of the effectiveness using fusion imaging in evaluation of patients with testis cancer. Methods: A prospective study of 49 patients presenting to Walter Reed Army Medical Center with testicular cancer from 2003 to 2009 was performed. Fusion imaging was compared with conventional imaging, tumor markers, pathologic results, and clinical follow-up. Results: There were 14 true positives, 33 true negatives, 1 false positive, and 1 false negative. Sensitivity, specificity, positive predictive value, and negative predictive value were 93.3, 97.0, 93.3, and 97.0% respectively. In 11 patient scenarios, fusion imaging differed from conventional imaging. Utility was found in superior lesion detection compared to helical computed tomography due to anatomical/functional image co-registration, detection of micrometastasis in lymph nodes (pathologic nodes < 1cm), surveillance for recurrence post-chemotherapy, differentiating fibrosis from active disease in nodes < 2.5cm, and acting as a quality assurance measure to computed tomography alone. Conclusions: In addition to demonstrating a sensitivity and specificity comparable or superior to conventional imaging, fusion imaging shows promise in providing additive data that may assist in clinical decision-making. PMID:21103077

  16. Fusion imaging: a novel staging modality in testis cancer.

    PubMed

    Sterbis, Joseph R; Rice, Kevin R; Javitt, Marcia C; Schenkman, Noah S; Brassell, Stephen A

    2010-11-05

    Computed tomography and chest radiographs provide the standard imaging for staging, treatment, and surveillance of testicular germ cell neoplasms. Positron emission tomography has recently been utilized for staging, but is somewhat limited in its ability to provide anatomic localization. Fusion imaging combines the metabolic information provided by positron emission tomography with the anatomic precision of computed tomography. To the best of our knowledge, this represents the first study of the effectiveness using fusion imaging in evaluation of patients with testis cancer. A prospective study of 49 patients presenting to Walter Reed Army Medical Center with testicular cancer from 2003 to 2009 was performed. Fusion imaging was compared with conventional imaging, tumor markers, pathologic results, and clinical follow-up. There were 14 true positives, 33 true negatives, 1 false positive, and 1 false negative. Sensitivity, specificity, positive predictive value, and negative predictive value were 93.3, 97.0, 93.3, and 97.0% respectively. In 11 patient scenarios, fusion imaging differed from conventional imaging. Utility was found in superior lesion detection compared to helical computed tomography due to anatomical/functional image co-registration, detection of micrometastasis in lymph nodes (pathologic nodes < 1cm), surveillance for recurrence post-chemotherapy, differentiating fibrosis from active disease in nodes < 2.5cm, and acting as a quality assurance measure to computed tomography alone. In addition to demonstrating a sensitivity and specificity comparable or superior to conventional imaging, fusion imaging shows promise in providing additive data that may assist in clinical decision-making.

  17. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    PubMed Central

    Kim, Terrence T.; Johnson, J. Patrick; Pashman, Robert; Drazin, Doniel

    2016-01-01

    We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy. PMID:27213152

  18. Diagnostic Imaging of the Hepatobiliary System: An Update.

    PubMed

    Marolf, Angela J

    2017-05-01

    Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Computers in aeronautics and space research at the Lewis Research Center

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This brochure presents a general discussion of the role of computers in aerospace research at NASA's Lewis Research Center (LeRC). Four particular areas of computer applications are addressed: computer modeling and simulation, computer assisted engineering, data acquisition and analysis, and computer controlled testing.

  20. Computer Series, 87.

    ERIC Educational Resources Information Center

    Moore, John W., Ed.

    1987-01-01

    Included are two articles related to the use of computers. One activity is a computer exercise in chemical reaction engineering and applied kinetics for undergraduate college students. The second article shows how computer-assisted analysis can be used with reaction rate data. (RH)

  1. Accounting for tissue heterogeneity in infrared spectroscopic imaging for accurate diagnosis of thyroid carcinoma subtypes.

    PubMed

    Martinez-Marin, David; Sreedhar, Hari; Varma, Vishal K; Eloy, Catarina; Sobrinho-Simões, Manuel; Kajdacsy-Balla, André; Walsh, Michael J

    2017-07-01

    Fourier transform infrared (FT-IR) microscopy was used to image tissue samples from twenty patients diagnosed with thyroid carcinoma. The spectral data were then used to differentiate between follicular thyroid carcinoma and follicular variant of papillary thyroid carcinoma using principle component analysis coupled with linear discriminant analysis and a Naïve Bayesian classifier operating on a set of computed spectral metrics. Classification of patients' disease type was accomplished by using average spectra from a wide region containing follicular cells, colloid, and fibrosis; however, classification of disease state at the pixel level was only possible when the extracted spectra were limited to follicular epithelial cells in the samples, excluding the relatively uninformative areas of fibrosis. The results demonstrate the potential of FT-IR microscopy as a tool to assist in the difficult diagnosis of these subtypes of thyroid cancer, and also highlights the importance of selectively and separately analyzing spectral information from different features of a tissue of interest.

  2. History of computer-assisted orthopedic surgery (CAOS) in sports medicine.

    PubMed

    Jackson, Douglas W; Simon, Timothy M

    2008-06-01

    Computer-assisted orthopedic surgery and navigation applications have a history rooted in the desire to link imaging technology with real-time anatomic landmarks. Although applications are still evolving in the clinical and research setting, computer-assisted orthopedic surgery has already demonstrated in certain procedures its potential for improving the surgeon's accuracy, reproducibility (once past the learning curve), and in reducing outlier outcomes. It is also being used as an educational tool to assist less experienced surgeons in interpreting measurements and precision placements related to well defined anatomic landmarks. It also can assist experienced surgeons, in real-time, plan their bony cuts, tunnel placement, and with ligament balancing. Presently, the additional time, the expense to acquire the needed software and hardware, and restricted reimbursement have slowed the widespread use of navigation. Its current applications have been primarily in joint replacement surgery, spine surgery, and trauma. It has not been widely used in the clinical setting for sports medicine procedures. Sports medicine applications such as individualizing tunnel placement in ligament surgery, opening wedge osteotomy with and without accompanying ligament reconstruction, and balancing and tensioning of the ligaments during the procedure (allowing real-time corrections if necessary) are currently being evaluated and being used on a limited clinical basis.

  3. Speckle interferometry. Data acquisition and control for the SPID instrument.

    NASA Astrophysics Data System (ADS)

    Altarac, S.; Tallon, M.; Thiebaut, E.; Foy, R.

    1998-08-01

    SPID (SPeckle Imaging by Deconvolution) is a new speckle camera currently under construction at CRAL-Observatoire de Lyon. Its high spectral resolution and high image restoration capabilities open new astrophysical programs. The instrument SPID is composed of four main optical modules which are fully automated and computer controlled by a software written in Tcl/Tk/Tix and C. This software provides an intelligent assistance to the user by choosing observational parameters as a function of atmospheric parameters, computed in real time, and the desired restored image quality. Data acquisition is made by a photon-counting detector (CP40). A VME-based computer under OS9 controls the detector and stocks the data. The intelligent system runs under Linux on a PC. A slave PC under DOS commands the motors. These 3 computers communicate through an Ethernet network. SPID can be considered as a precursor for VLT's (Very Large Telescope, four 8-meter telescopes currently built in Chile by European Southern Observatory) very high spatial resolution camera.

  4. Rapid execution of fan beam image reconstruction algorithms using efficient computational techniques and special-purpose processors

    NASA Astrophysics Data System (ADS)

    Gilbert, B. K.; Robb, R. A.; Chu, A.; Kenue, S. K.; Lent, A. H.; Swartzlander, E. E., Jr.

    1981-02-01

    Rapid advances during the past ten years of several forms of computer-assisted tomography (CT) have resulted in the development of numerous algorithms to convert raw projection data into cross-sectional images. These reconstruction algorithms are either 'iterative,' in which a large matrix algebraic equation is solved by successive approximation techniques; or 'closed form'. Continuing evolution of the closed form algorithms has allowed the newest versions to produce excellent reconstructed images in most applications. This paper will review several computer software and special-purpose digital hardware implementations of closed form algorithms, either proposed during the past several years by a number of workers or actually implemented in commercial or research CT scanners. The discussion will also cover a number of recently investigated algorithmic modifications which reduce the amount of computation required to execute the reconstruction process, as well as several new special-purpose digital hardware implementations under development in laboratories at the Mayo Clinic.

  5. Quantification of video-taped images in microcirculation research using inexpensive imaging software (Adobe Photoshop).

    PubMed

    Brunner, J; Krummenauer, F; Lehr, H A

    2000-04-01

    Study end-points in microcirculation research are usually video-taped images rather than numeric computer print-outs. Analysis of these video-taped images for the quantification of microcirculatory parameters usually requires computer-based image analysis systems. Most software programs for image analysis are custom-made, expensive, and limited in their applicability to selected parameters and study end-points. We demonstrate herein that an inexpensive, commercially available computer software (Adobe Photoshop), run on a Macintosh G3 computer with inbuilt graphic capture board provides versatile, easy to use tools for the quantification of digitized video images. Using images obtained by intravital fluorescence microscopy from the pre- and postischemic muscle microcirculation in the skinfold chamber model in hamsters, Photoshop allows simple and rapid quantification (i) of microvessel diameters, (ii) of the functional capillary density and (iii) of postischemic leakage of FITC-labeled high molecular weight dextran from postcapillary venules. We present evidence of the technical accuracy of the software tools and of a high degree of interobserver reliability. Inexpensive commercially available imaging programs (i.e., Adobe Photoshop) provide versatile tools for image analysis with a wide range of potential applications in microcirculation research.

  6. Computer-Assisted Training in the Comprehension of Authentic French Speech: A Closer View

    ERIC Educational Resources Information Center

    Hoeflaak, Arie

    2004-01-01

    In this article, the development of a computer-assisted listening comprehension project is described. First, we comment briefly on the points of departure, the need for autonomous learning against the background of recent changes in Dutch education, and the role of learning strategies. Then, an error analysis, the programs used for this project,…

  7. Computer vision-based analysis of foods: a non-destructive colour measurement tool to monitor quality and safety.

    PubMed

    Mogol, Burçe Ataç; Gökmen, Vural

    2014-05-01

    Computer vision-based image analysis has been widely used in food industry to monitor food quality. It allows low-cost and non-contact measurements of colour to be performed. In this paper, two computer vision-based image analysis approaches are discussed to extract mean colour or featured colour information from the digital images of foods. These types of information may be of particular importance as colour indicates certain chemical changes or physical properties in foods. As exemplified here, the mean CIE a* value or browning ratio determined by means of computer vision-based image analysis algorithms can be correlated with acrylamide content of potato chips or cookies. Or, porosity index as an important physical property of breadcrumb can be calculated easily. In this respect, computer vision-based image analysis provides a useful tool for automatic inspection of food products in a manufacturing line, and it can be actively involved in the decision-making process where rapid quality/safety evaluation is needed. © 2013 Society of Chemical Industry.

  8. High-End Scientific Computing

    EPA Pesticide Factsheets

    EPA uses high-end scientific computing, geospatial services and remote sensing/imagery analysis to support EPA's mission. The Center for Environmental Computing (CEC) assists the Agency's program offices and regions to meet staff needs in these areas.

  9. Ultrasonics and space instrumentation

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The design topic selected was an outgrowth of the experimental design work done in the Fluid Behavior in Space experiment, which relies on the measurement of minute changes of the pressure and temperature to obtain reasonably accurate volume determinations. An alternative method of volume determination is the use of ultrasonic imaging. An ultrasonic wave system is generated by wall mounted transducer arrays. The interior liquid configuration causes reflection and refraction of the pattern so that analysis of the received wave system provides a description of the configuration and hence volume. Both continuous and chirp probe beams were used in a laboratory experiment simulating a surface wetting propellant. The hardware included a simulated tank with gaseous voids, transmitting and receiving transducers, transmitters, receivers, computer interface, and computer. Analysis software was developed for image generation and interpretation of results. Space instrumentation was pursued in support of a number of experiments under development for GAS flights. The program included thirty undergraduate students pursuing major qualifying project work under the guidance of eight faculty supported by a teaching assistant. Both mechanical and electrical engineering students designed and built several microprocessor systems to measure parameters such as temperature, acceleration, pressure, velocity, and circulation in order to determine combustion products, vortex formation, gas entrainment, EMR emissions from thunderstorms, and milli-g-accelerations due to crew motions.

  10. Quantitation of heavy ion damage to the mammalian brain - Some preliminary findings

    NASA Technical Reports Server (NTRS)

    Cox, A. B.; Kraft, L. M.

    1984-01-01

    For several years, studies have been conducted regarding late effects of particulate radiations in mammalian tissues, taking into account the brains of rodents and lagomorphs. Recently, it has become feasible to quantify pathological damage and morpho-physiologic alterations accurately in large numbers of histological specimens. New investigative procedures make use of computer-assisted automated image analysis systems. Details regarding the employed methodology are discussed along with the results of the information. The radiations of high linear energy transfer (LET) cause apparently earlier and more dramatic shrinkage of olfactory glomeruli in exposed rabbit brains than comparable doses of Co-60 gamma photons.

  11. Diagnosis and Characterization of Patellofemoral Instability: Review of Available Imaging Modalities.

    PubMed

    Haj-Mirzaian, Arya; Thawait, Gaurav K; Tanaka, Miho J; Demehri, Shadpour

    2017-06-01

    Patellofemoral instability (PI) is defined as single or multiple episodes of patellar dislocation. Imaging modalities are useful for characterization of patellar malalignment, maltracking, underlying morphologic abnormalities, and stabilizing soft-tissue injuries. Using these findings, orthopedic surgeons can decide when to operate, determine the best operation, and measure degree of correction postoperatively in PI patients. Also, these methods assist with PI diagnosis in some suspicious cases. Magnetic resonance imaging is the preferred method especially in the setting of acute dislocations. Multidetector computed tomography allows a more accurate assessment for malalignment such as patellar tilt and lateral subluxation and secondary osteoarthritis. Dynamic magnetic resonance imaging and 4-dimensional computed tomography have been introduced for better kinematic assessment of the patellofemoral maltracking during extension-flexion motions. In this review article, we will discuss the currently available evidence regarding both the conventional and the novel imaging modalities that can be used for diagnosis and characterization of PI.

  12. Tracked 3D ultrasound in radio-frequency liver ablation

    NASA Astrophysics Data System (ADS)

    Boctor, Emad M.; Fichtinger, Gabor; Taylor, Russell H.; Choti, Michael A.

    2003-05-01

    Recent studies have shown that radio frequency (RF) ablation is a simple, safe and potentially effective treatment for selected patients with liver metastases. Despite all recent therapeutic advancements, however, intra-procedural target localization and precise and consistent placement of the tissue ablator device are still unsolved problems. Various imaging modalities, including ultrasound (US) and computed tomography (CT) have been tried as guidance modalities. Transcutaneous US imaging, due to its real-time nature, may be beneficial in many cases, but unfortunately, fails to adequately visualize the tumor in many cases. Intraoperative or laparoscopic US, on the other hand, provides improved visualization and target imaging. This paper describes a system for computer-assisted RF ablation of liver tumors, combining navigational tracking of a conventional imaging ultrasound probe to produce 3D ultrasound imaging with a tracked RF ablation device supported by a passive mechanical arm and spatially registered to the ultrasound volume.

  13. Markerless laser registration in image-guided oral and maxillofacial surgery.

    PubMed

    Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan

    2004-07-01

    The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.

  14. Texture analysis of pulmonary parenchymateous changes related to pulmonary thromboembolism in dogs - a novel approach using quantitative methods.

    PubMed

    Marschner, C B; Kokla, M; Amigo, J M; Rozanski, E A; Wiinberg, B; McEvoy, F J

    2017-07-11

    Diagnosis of pulmonary thromboembolism (PTE) in dogs relies on computed tomography pulmonary angiography (CTPA), but detailed interpretation of CTPA images is demanding for the radiologist and only large vessels may be evaluated. New approaches for better detection of smaller thrombi include dual energy computed tomography (DECT) as well as computer assisted diagnosis (CAD) techniques. The purpose of this study was to investigate the performance of quantitative texture analysis for detecting dogs with PTE using grey-level co-occurrence matrices (GLCM) and multivariate statistical classification analyses. CT images from healthy (n = 6) and diseased (n = 29) dogs with and without PTE confirmed on CTPA were segmented so that only tissue with CT numbers between -1024 and -250 Houndsfield Units (HU) was preserved. GLCM analysis and subsequent multivariate classification analyses were performed on texture parameters extracted from these images. Leave-one-dog-out cross validation and receiver operator characteristic (ROC) showed that the models generated from the texture analysis were able to predict healthy dogs with optimal levels of performance. Partial Least Square Discriminant Analysis (PLS-DA) obtained a sensitivity of 94% and a specificity of 96%, while Support Vector Machines (SVM) yielded a sensitivity of 99% and a specificity of 100%. The models, however, performed worse in classifying the type of disease in the diseased dog group: In diseased dogs with PTE sensitivities were 30% (PLS-DA) and 38% (SVM), and specificities were 80% (PLS-DA) and 89% (SVM). In diseased dogs without PTE the sensitivities of the models were 59% (PLS-DA) and 79% (SVM) and specificities were 79% (PLS-DA) and 82% (SVM). The results indicate that texture analysis of CTPA images using GLCM is an effective tool for distinguishing healthy from abnormal lung. Furthermore the texture of pulmonary parenchyma in dogs with PTE is altered, when compared to the texture of pulmonary parenchyma of healthy dogs. The models' poorer performance in classifying dogs within the diseased group, may be related to the low number of dogs compared to texture variables, a lack of balanced number of dogs within each group or a real lack of difference in the texture features among the diseased dogs.

  15. [Development of an original computer program FISHMet: use for molecular cytogenetic diagnosis and genome mapping by fluorescent in situ hybridization (FISH)].

    PubMed

    Iurov, Iu B; Khazatskiĭ, I A; Akindinov, V A; Dovgilov, L V; Kobrinskiĭ, B A; Vorsanova, S G

    2000-08-01

    Original software FISHMet has been developed and tried for improving the efficiency of diagnosis of hereditary diseases caused by chromosome aberrations and for chromosome mapping by fluorescent in situ hybridization (FISH) method. The program allows creation and analysis of pseudocolor chromosome images and hybridization signals in the Windows 95 system, allows computer analysis and editing of the results of pseudocolor hybridization in situ, including successive imposition of initial black-and-white images created using fluorescent filters (blue, green, and red), and editing of each image individually or of a summary pseudocolor image in BMP, TIFF, and JPEG formats. Components of image computer analysis system (LOMO, Leitz Ortoplan, and Axioplan fluorescent microscopes, COHU 4910 and Sanyo VCB-3512P CCD cameras, Miro-Video, Scion LG-3 and VG-5 image capture maps, and Pentium 100 and Pentium 200 computers) and specialized software for image capture and visualization (Scion Image PC and Video-Cup) have been used with good results in the study.

  16. A novel computer algorithm for modeling and treating mandibular fractures: A pilot study.

    PubMed

    Rizzi, Christopher J; Ortlip, Timothy; Greywoode, Jewel D; Vakharia, Kavita T; Vakharia, Kalpesh T

    2017-02-01

    To describe a novel computer algorithm that can model mandibular fracture repair. To evaluate the algorithm as a tool to model mandibular fracture reduction and hardware selection. Retrospective pilot study combined with cross-sectional survey. A computer algorithm utilizing Aquarius Net (TeraRecon, Inc, Foster City, CA) and Adobe Photoshop CS6 (Adobe Systems, Inc, San Jose, CA) was developed to model mandibular fracture repair. Ten different fracture patterns were selected from nine patients who had already undergone mandibular fracture repair. The preoperative computed tomography (CT) images were processed with the computer algorithm to create virtual images that matched the actual postoperative three-dimensional CT images. A survey comparing the true postoperative image with the virtual postoperative images was created and administered to otolaryngology resident and attending physicians. They were asked to rate on a scale from 0 to 10 (0 = completely different; 10 = identical) the similarity between the two images in terms of the fracture reduction and fixation hardware. Ten mandible fracture cases were analyzed and processed. There were 15 survey respondents. The mean score for overall similarity between the images was 8.41 ± 0.91; the mean score for similarity of fracture reduction was 8.61 ± 0.98; and the mean score for hardware appearance was 8.27 ± 0.97. There were no significant differences between attending and resident responses. There were no significant differences based on fracture location. This computer algorithm can accurately model mandibular fracture repair. Images created by the algorithm are highly similar to true postoperative images. The algorithm can potentially assist a surgeon planning mandibular fracture repair. 4. Laryngoscope, 2016 127:331-336, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Whiteboards at Your Service: Interactive Whiteboards Can Assist Teachers, Students, Trainers, and District Office Personnel

    ERIC Educational Resources Information Center

    Branzburg, Jeffrey

    2007-01-01

    Interactive whiteboards have made quite a splash in classrooms in recent years. When a computer image is projected on the whiteboard using an LCD projector, users can directly control the computer from the whiteboard. In some systems such as Smart and Mimio, the finger is used in place of a mouse to open and run programs or move windows around. In…

  18. 4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Zhang, Dong Ping; Edwards, Eddie; Mei, Lin; Rueckert, Daniel

    2009-02-01

    In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography( CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to have a 4D cardiac motion model to be registered with the stereo endoscopic images acquired intraoperatively using the da Vinci robotic system. In this paper, we are investigating the extraction of the coronary arteries and the modelling of their motion from a dynamic sequence of cardiac CT. We use a multi-scale vesselness filter to enhance vessels in the cardiac CT images. The centerlines of the arteries are extracted using a ridge traversal algorithm. Using this method the coronaries can be extracted in near real-time as only local information is used in vessel tracking. To compute the deformation of the coronaries due to cardiac motion, the motion is extracted from a dynamic sequence of cardiac CT. Each timeframe in this sequence is registered to the end-diastole timeframe of the sequence using a non-rigid registration algorithm based on free-form deformations. Once the images have been registered a dynamic motion model of the coronaries can be obtained by applying the computed free-form deformations to the extracted coronary arteries. To validate the accuracy of the motion model we compare the actual position of the coronaries in each time frame with the predicted position of the coronaries as estimated from the non-rigid registration. We expect that this motion model of coronaries can facilitate the planning of TECAB surgery, and through the registration with real-time endoscopic video images it can reduce the conversion rate from TECAB to conventional procedures.

  19. Virtual surgical planning and 3D printing in repeat calvarial vault reconstruction for craniosynostosis: technical note.

    PubMed

    LoPresti, Melissa; Daniels, Bradley; Buchanan, Edward P; Monson, Laura; Lam, Sandi

    2017-04-01

    Repeat surgery for restenosis after initial nonsyndromic craniosynostosis intervention is sometimes needed. Calvarial vault reconstruction through a healed surgical bed adds a level of intraoperative complexity and may benefit from preoperative and intraoperative definitions of biometric and aesthetic norms. Computer-assisted design and manufacturing using 3D imaging allows the precise formulation of operative plans in anticipation of surgical intervention. 3D printing turns virtual plans into anatomical replicas, templates, or customized implants by using a variety of materials. The authors present a technical note illustrating the use of this technology: a repeat calvarial vault reconstruction that was planned and executed using computer-assisted design and 3D printed intraoperative guides.

  20. The impact of digital imaging in the field of cytopathology.

    PubMed

    Pantanowitz, Liron; Hornish, Maryanne; Goulart, Robert A

    2009-03-06

    With the introduction of digital imaging, pathology is undergoing a digital transformation. In the field of cytology, digital images are being used for telecytology, automated screening of Pap test slides, training and education (e.g. online digital atlases), and proficiency testing. To date, there has been no systematic review on the impact of digital imaging on the practice of cytopathology. This article critically addresses the emerging role of computer-assisted screening and the application of digital imaging to the field of cytology, including telecytology, virtual microscopy, and the impact of online cytology resources. The role of novel diagnostic techniques like image cytometry is also reviewed.

  1. A low-cost universal cumulative gating circuit for small and large animal clinical imaging

    NASA Astrophysics Data System (ADS)

    Gioux, Sylvain; Frangioni, John V.

    2008-02-01

    Image-assisted diagnosis and therapy is becoming more commonplace in medicine. However, most imaging techniques suffer from voluntary or involuntary motion artifacts, especially cardiac and respiratory motions, which degrade image quality. Current software solutions either induce computational overhead or reject out-of-focus images after acquisition. In this study we demonstrate a hardware-only gating circuit that accepts multiple, pseudo-periodic signals and produces a single TTL (0-5 V) imaging window of accurate phase and period. The electronic circuit Gerber files described in this article and the list of components are available online at www.frangionilab.org.

  2. Feasibility and safety of augmented-reality glass for computed tomography-assisted percutaneous revascularization of coronary chronic total occlusion: A single center prospective pilot study.

    PubMed

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Staruch, Adam D; Kepka, Cezary; Rokicki, Jakub K; Sieradzki, Bartosz; Witkowski, Adam

    2017-11-01

    Percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) may be facilitated by projection of coronary computed tomography angiography (CTA) datasets in the catheterization laboratory. There is no data on the feasibility and safety outcomes of CTA-assisted CTO PCI using a wearable augmented-reality glass. A total of 15 patients scheduled for elective antegrade CTO intervention were prospectively enrolled and underwent preprocedural coronary CTA. Three-dimensional and curved multiplanar CT reconstructions were transmitted to a head-mounted hands-free computer worn by interventional cardiologists during CTO PCI to provide additional information on CTO tortuosity and calcification. The results of CTO PCI using a wearable computer were compared with a time-matched prospective angiographic registry of 59 patients undergoing antegrade CTO PCI without a wearable computer. Operators' satisfaction was assessed by a 5-point Likert scale. Mean age was 64 ± 8 years and the mean J-CTO score was 2.1 ± 0.9 in the CTA-assisted group. The voice-activated co-registration and review of CTA images in a wearable computer during CTO PCI were feasible and highly rated by PCI operators (4.7/5 points). There were no major adverse cardiovascular events. Compared with standard CTO PCI, CTA-assisted recanalization of CTO using a wearable computer showed more frequent selection of the first-choice stiff wire (0% vs 40%, p < 0.001) and lower contrast exposure (166 ± 52 vs 134 ± 43 ml, p = 0.03). Overall CTO success rates and safety outcomes remained similar between both groups. CTA-assisted CTO PCI using an augmented-reality glass is feasible and safe, and might reduce the resources required for the interventional treatment of CTO. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. User's manual for SEDCALC, a computer program for computation of suspended-sediment discharge

    USGS Publications Warehouse

    Koltun, G.F.; Gray, John R.; McElhone, T.J.

    1994-01-01

    Sediment-Record Calculations (SEDCALC), a menu-driven set of interactive computer programs, was developed to facilitate computation of suspended-sediment records. The programs comprising SEDCALC were developed independently in several District offices of the U.S. Geological Survey (USGS) to minimize the intensive labor associated with various aspects of sediment-record computations. SEDCALC operates on suspended-sediment-concentration data stored in American Standard Code for Information Interchange (ASCII) files in a predefined card-image format. Program options within SEDCALC can be used to assist in creating and editing the card-image files, as well as to reformat card-image files to and from formats used by the USGS Water-Quality System. SEDCALC provides options for creating card-image files containing time series of equal-interval suspended-sediment concentrations from 1. digitized suspended-sediment-concentration traces, 2. linear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals, and 3. nonlinear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals. Suspended-sediment discharge can be computed from the streamflow and suspended-sediment-concentration data or by application of transport relations derived by regressing log-transformed instantaneous streamflows on log-transformed instantaneous suspended-sediment concentrations or discharges. The computed suspended-sediment discharge data are stored in card-image files that can be either directly imported to the USGS Automated Data Processing System or used to generate plots by means of other SEDCALC options.

  4. From medical images to minimally invasive intervention: Computer assistance for robotic surgery.

    PubMed

    Lee, Su-Lin; Lerotic, Mirna; Vitiello, Valentina; Giannarou, Stamatia; Kwok, Ka-Wai; Visentini-Scarzanella, Marco; Yang, Guang-Zhong

    2010-01-01

    Minimally invasive surgery has been established as an important way forward in surgery for reducing patient trauma and hospitalization with improved prognosis. The introduction of robotic assistance enhances the manual dexterity and accuracy of instrument manipulation. Further development of the field in using pre- and intra-operative imaging guidance requires the integration of the general anatomy of the patient with clear pathologic indications and geometrical information for preoperative planning and intra-operative manipulation. It also requires effective visualization and the recreation of haptic and tactile sensing with dynamic active constraints to improve consistency and safety of the surgical procedures. This paper describes key technical considerations of tissue deformation tracking, 3D reconstruction, subject-specific modeling, image guidance and augmented reality for robotic assisted minimally invasive surgery. It highlights the importance of adapting preoperative surgical planning according to intra-operative data and illustrates how dynamic information such as tissue deformation can be incorporated into the surgical navigation framework. Some of the recent trends are discussed in terms of instrument design and the usage of dynamic active constraints and human-robot perceptual docking for robotic assisted minimally invasive surgery. Copyright 2009 Elsevier Ltd. All rights reserved.

  5. The approximate entropy concept extended to three dimensions for calibrated, single parameter structural complexity interrogation of volumetric images.

    PubMed

    Moore, Christopher; Marchant, Thomas

    2017-07-12

    Reconstructive volumetric imaging permeates medical practice because of its apparently clear depiction of anatomy. However, the tell tale signs of abnormality and its delineation for treatment demand experts work at the threshold of visibility for hints of structure. Hitherto, a suitable assistive metric that chimes with clinical experience has been absent. This paper develops the complexity measure approximate entropy (ApEn) from its 1D physiological origin into a three-dimensional (3D) algorithm to fill this gap. The first 3D algorithm for this is presented in detail. Validation results for known test arrays are followed by a comparison of fan-beam and cone-beam x-ray computed tomography image volumes used in image guided radiotherapy for cancer. Results show the structural detail down to individual voxel level, the strength of which is calibrated by the ApEn process itself. The potential for application in machine assisted manual interaction and automated image processing and interrogation, including radiomics associated with predictive outcome modeling, is discussed.

  6. A deep semantic mobile application for thyroid cytopathology

    NASA Astrophysics Data System (ADS)

    Kim, Edward; Corte-Real, Miguel; Baloch, Zubair

    2016-03-01

    Cytopathology is the study of disease at the cellular level and often used as a screening tool for cancer. Thyroid cytopathology is a branch of pathology that studies the diagnosis of thyroid lesions and diseases. A pathologist views cell images that may have high visual variance due to different anatomical structures and pathological characteristics. To assist the physician with identifying and searching through images, we propose a deep semantic mobile application. Our work augments recent advances in the digitization of pathology and machine learning techniques, where there are transformative opportunities for computers to assist pathologists. Our system uses a custom thyroid ontology that can be augmented with multimedia metadata extracted from images using deep machine learning techniques. We describe the utilization of a particular methodology, deep convolutional neural networks, to the application of cytopathology classification. Our method is able to leverage networks that have been trained on millions of generic images, to medical scenarios where only hundreds or thousands of images exist. We demonstrate the benefits of our framework through both quantitative and qualitative results.

  7. The approximate entropy concept extended to three dimensions for calibrated, single parameter structural complexity interrogation of volumetric images

    NASA Astrophysics Data System (ADS)

    Moore, Christopher; Marchant, Thomas

    2017-08-01

    Reconstructive volumetric imaging permeates medical practice because of its apparently clear depiction of anatomy. However, the tell tale signs of abnormality and its delineation for treatment demand experts work at the threshold of visibility for hints of structure. Hitherto, a suitable assistive metric that chimes with clinical experience has been absent. This paper develops the complexity measure approximate entropy (ApEn) from its 1D physiological origin into a three-dimensional (3D) algorithm to fill this gap. The first 3D algorithm for this is presented in detail. Validation results for known test arrays are followed by a comparison of fan-beam and cone-beam x-ray computed tomography image volumes used in image guided radiotherapy for cancer. Results show the structural detail down to individual voxel level, the strength of which is calibrated by the ApEn process itself. The potential for application in machine assisted manual interaction and automated image processing and interrogation, including radiomics associated with predictive outcome modeling, is discussed.

  8. Latent Semantic Analysis as a Method of Content-Based Image Retrieval in Medical Applications

    ERIC Educational Resources Information Center

    Makovoz, Gennadiy

    2010-01-01

    The research investigated whether a Latent Semantic Analysis (LSA)-based approach to image retrieval can map pixel intensity into a smaller concept space with good accuracy and reasonable computational cost. From a large set of M computed tomography (CT) images, a retrieval query found all images for a particular patient based on semantic…

  9. Computer-Mediated Glosses in Second Language Reading Comprehension and Vocabulary Learning: A Meta-Analysis

    ERIC Educational Resources Information Center

    Abraham, Lee B.

    2008-01-01

    Language learners have unprecedented opportunities for developing second language literacy skills and intercultural understanding by reading authentic texts on the Internet and in multimedia computer-assisted language learning environments. This article presents findings from a meta-analysis of 11 studies of computer-mediated glosses in second…

  10. Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: contemporary research topics relevant to the lung image database consortium.

    PubMed

    Dodd, Lori E; Wagner, Robert F; Armato, Samuel G; McNitt-Gray, Michael F; Beiden, Sergey; Chan, Heang-Ping; Gur, David; McLennan, Geoffrey; Metz, Charles E; Petrick, Nicholas; Sahiner, Berkman; Sayre, Jim

    2004-04-01

    Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technology provide detection of smaller lung nodules and offer a potentially effective screening tool. The large number of images per exam, however, requires considerable radiologist time for interpretation and is an impediment to clinical throughput. Thus, computer-aided diagnosis (CAD) methods are needed to assist radiologists with their decision making. To promote the development of CAD methods, the National Cancer Institute formed the Lung Image Database Consortium (LIDC). The LIDC is charged with developing the consensus and standards necessary to create an image database of multidetector-row computed tomography lung images as a resource for CAD researchers. To develop such a prospective database, its potential uses must be anticipated. The ultimate applications will influence the information that must be included along with the images, the relevant measures of algorithm performance, and the number of required images. In this article we outline assessment methodologies and statistical issues as they relate to several potential uses of the LIDC database. We review methods for performance assessment and discuss issues of defining "truth" as well as the complications that arise when truth information is not available. We also discuss issues about sizing and populating a database.

  11. Research and the Personal Computer.

    ERIC Educational Resources Information Center

    Blackburn, D. A.

    1989-01-01

    Discussed is the history and elements of the personal computer. Its uses as a laboratory assistant and generic toolkit for mathematical analysis and modeling are included. The future of the personal computer in research is addressed. (KR)

  12. Computer-assisted three-dimensional reconstructions of ( sup 14 C)-2-deoxy-D-glucose metabolism in cat lumbosacral spinal cord following cutaneous stimulation of the hindfoot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crockett, D.P.; Smith, W.K.; Proshansky, E.

    1989-10-08

    We report on computer-assisted three-dimensional reconstruction of spinal cord activity associated with stimulation of the plantar cushion (PC) as revealed by (14C)-2-deoxy-D-glucose (2-DG) serial autoradiographs. Moderate PC stimulation in cats elicits a reflex phasic plantar flexion of the toes. Four cats were chronically spinalized at about T6 under barbiturate anesthesia. Four to 11 days later, the cats were injected (i.v.) with 2-DG (100 microCi/kg) and the PC was electrically stimulated with needle electrodes at 2-5 times threshold for eliciting a reflex. Following stimulation, the spinal cord was processed for autoradiography. Subsequently, autoradiographs, representing approximately 8-18 mm from spinal segments L6-S1,more » were digitized for computer analysis and 3-D reconstruction. Several strategies of analysis were employed: (1) Three-dimensional volume images were color-coded to represent different levels of functional activity. (2) On the reconstructed volumes, virtual sections were made in the horizontal, sagittal, and transverse planes to view regions of 2-DG activity. (3) In addition, we were able to sample different regions within the grey and white matter semi-quantitatively (i.e., pixel intensity) from section to section to reveal differences between ipsi- and contralateral activity, as well as possible variation between sections. These analyses revealed 2-DG activity associated with moderate PC stimulation, not only in the ipsilateral dorsal horn as we had previously demonstrated, but also in both the ipsilateral and contralateral ventral horns, as well as in the intermediate grey matter. The use of novel computer analysis techniques--combined with an unanesthetized preparation--enabled us to demonstrate that the increased metabolic activity in the lumbosacral spinal cord associated with PC stimulation was much more extensive than had heretofore been observed.« less

  13. 76 FR 30978 - Ivestigations Regarding Certifications of Eligibility To Apply for Worker Adjustment Assistance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-27

    ...)........ Miamisburg, OH......... 05/10/11 05/06/11 80166 Computer Sciences El Segundo, CA......... 05/10/11 05/06/11..., Youngstown, OH......... 05/10/11 04/30/11 Inc. (Company). 80170 Getty Images (State/One- Los Angeles, CA...

  14. Classification of Suncus murinus species complex (Soricidae: Crocidurinae) in Peninsular Malaysia using image analysis and machine learning approaches.

    PubMed

    Abu, Arpah; Leow, Lee Kien; Ramli, Rosli; Omar, Hasmahzaiti

    2016-12-22

    Taxonomists frequently identify specimen from various populations based on the morphological characteristics and molecular data. This study looks into another invasive process in identification of house shrew (Suncus murinus) using image analysis and machine learning approaches. Thus, an automated identification system is developed to assist and simplify this task. In this study, seven descriptors namely area, convex area, major axis length, minor axis length, perimeter, equivalent diameter and extent which are based on the shape are used as features to represent digital image of skull that consists of dorsal, lateral and jaw views for each specimen. An Artificial Neural Network (ANN) is used as classifier to classify the skulls of S. murinus based on region (northern and southern populations of Peninsular Malaysia) and sex (adult male and female). Thus, specimen classification using Training data set and identification using Testing data set were performed through two stages of ANNs. At present, the classifier used has achieved an accuracy of 100% based on skulls' views. Classification and identification to regions and sexes have also attained 72.5%, 87.5% and 80.0% of accuracy for dorsal, lateral, and jaw views, respectively. This results show that the shape characteristic features used are substantial because they can differentiate the specimens based on regions and sexes up to the accuracy of 80% and above. Finally, an application was developed and can be used for the scientific community. This automated system demonstrates the practicability of using computer-assisted systems in providing interesting alternative approach for quick and easy identification of unknown species.

  15. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  16. CT-scout based, semi-automated vertebral morphometry after digital image enhancement.

    PubMed

    Glinkowski, Wojciech M; Narloch, Jerzy

    2017-09-01

    Radiographic diagnosis of osteoporotic vertebral fracture is necessary to reduce its substantial associated morbidity. Computed tomography (CT) scout has recently been demonstrated as a reliable technique for vertebral fracture diagnosis. Software assistance may help to overcome some limitations of that diagnostics. We aimed to evaluate whether digital image enhancement improved the capacity of one of the existing software to detect fractures semi-automatically. CT scanograms of patients suffering from osteoporosis, with or without vertebral fractures were analyzed. The original set of CT scanograms were triplicated and digitally modified to improve edge detection using three different techniques: SHARPENING, UNSHARP MASKING, and CONVOLUTION. The manual morphometric analysis identified 1485 vertebrae, 200 of which were classified as fractured. Unadjusted morphometry (AUTOMATED with no digital enhancement) found 63 fractures, 33 of which were true positive (i.e., it correctly identified 52% of the fractures); SHARPENING detected 57 fractures (30 true positives, 53%); UNSHARP MASKING yielded 30 (13 true positives, 43%); and CONVOLUTION found 24 fractures (9 true positives, 38%). The intra-reader reliability for height ratios did not significantly improve with image enhancement (kappa ranged 0.22-0.41 for adjusted measurements and 0.16-0.38 for unadjusted). Similarly, the inter-reader agreement for prevalent fractures did not significantly improve with image enhancement (kappa 0.29-0.56 and -0.01 to 0.23 for adjusted and unadjusted measurements, respectively). Our results suggest that digital image enhancement does not improve software-assisted vertebral fracture detection by CT scout. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Down syndrome detection from facial photographs using machine learning techniques

    NASA Astrophysics Data System (ADS)

    Zhao, Qian; Rosenbaum, Kenneth; Sze, Raymond; Zand, Dina; Summar, Marshall; Linguraru, Marius George

    2013-02-01

    Down syndrome is the most commonly occurring chromosomal condition; one in every 691 babies in United States is born with it. Patients with Down syndrome have an increased risk for heart defects, respiratory and hearing problems and the early detection of the syndrome is fundamental for managing the disease. Clinically, facial appearance is an important indicator in diagnosing Down syndrome and it paves the way for computer-aided diagnosis based on facial image analysis. In this study, we propose a novel method to detect Down syndrome using photography for computer-assisted image-based facial dysmorphology. Geometric features based on facial anatomical landmarks, local texture features based on the Contourlet transform and local binary pattern are investigated to represent facial characteristics. Then a support vector machine classifier is used to discriminate normal and abnormal cases; accuracy, precision and recall are used to evaluate the method. The comparison among the geometric, local texture and combined features was performed using the leave-one-out validation. Our method achieved 97.92% accuracy with high precision and recall for the combined features; the detection results were higher than using only geometric or texture features. The promising results indicate that our method has the potential for automated assessment for Down syndrome from simple, noninvasive imaging data.

  18. Multispectral image analysis for object recognition and classification

    NASA Astrophysics Data System (ADS)

    Viau, C. R.; Payeur, P.; Cretu, A.-M.

    2016-05-01

    Computer and machine vision applications are used in numerous fields to analyze static and dynamic imagery in order to assist or automate decision-making processes. Advancements in sensor technologies now make it possible to capture and visualize imagery at various wavelengths (or bands) of the electromagnetic spectrum. Multispectral imaging has countless applications in various fields including (but not limited to) security, defense, space, medical, manufacturing and archeology. The development of advanced algorithms to process and extract salient information from the imagery is a critical component of the overall system performance. The fundamental objective of this research project was to investigate the benefits of combining imagery from the visual and thermal bands of the electromagnetic spectrum to improve the recognition rates and accuracy of commonly found objects in an office setting. A multispectral dataset (visual and thermal) was captured and features from the visual and thermal images were extracted and used to train support vector machine (SVM) classifiers. The SVM's class prediction ability was evaluated separately on the visual, thermal and multispectral testing datasets.

  19. Sensor-based architecture for medical imaging workflow analysis.

    PubMed

    Silva, Luís A Bastião; Campos, Samuel; Costa, Carlos; Oliveira, José Luis

    2014-08-01

    The growing use of computer systems in medical institutions has been generating a tremendous quantity of data. While these data have a critical role in assisting physicians in the clinical practice, the information that can be extracted goes far beyond this utilization. This article proposes a platform capable of assembling multiple data sources within a medical imaging laboratory, through a network of intelligent sensors. The proposed integration framework follows a SOA hybrid architecture based on an information sensor network, capable of collecting information from several sources in medical imaging laboratories. Currently, the system supports three types of sensors: DICOM repository meta-data, network workflows and examination reports. Each sensor is responsible for converting unstructured information from data sources into a common format that will then be semantically indexed in the framework engine. The platform was deployed in the Cardiology department of a central hospital, allowing identification of processes' characteristics and users' behaviours that were unknown before the utilization of this solution.

  20. Current and future trends in marine image annotation software

    NASA Astrophysics Data System (ADS)

    Gomes-Pereira, Jose Nuno; Auger, Vincent; Beisiegel, Kolja; Benjamin, Robert; Bergmann, Melanie; Bowden, David; Buhl-Mortensen, Pal; De Leo, Fabio C.; Dionísio, Gisela; Durden, Jennifer M.; Edwards, Luke; Friedman, Ariell; Greinert, Jens; Jacobsen-Stout, Nancy; Lerner, Steve; Leslie, Murray; Nattkemper, Tim W.; Sameoto, Jessica A.; Schoening, Timm; Schouten, Ronald; Seager, James; Singh, Hanumant; Soubigou, Olivier; Tojeira, Inês; van den Beld, Inge; Dias, Frederico; Tempera, Fernando; Santos, Ricardo S.

    2016-12-01

    Given the need to describe, analyze and index large quantities of marine imagery data for exploration and monitoring activities, a range of specialized image annotation tools have been developed worldwide. Image annotation - the process of transposing objects or events represented in a video or still image to the semantic level, may involve human interactions and computer-assisted solutions. Marine image annotation software (MIAS) have enabled over 500 publications to date. We review the functioning, application trends and developments, by comparing general and advanced features of 23 different tools utilized in underwater image analysis. MIAS requiring human input are basically a graphical user interface, with a video player or image browser that recognizes a specific time code or image code, allowing to log events in a time-stamped (and/or geo-referenced) manner. MIAS differ from similar software by the capability of integrating data associated to video collection, the most simple being the position coordinates of the video recording platform. MIAS have three main characteristics: annotating events in real time, posteriorly to annotation and interact with a database. These range from simple annotation interfaces, to full onboard data management systems, with a variety of toolboxes. Advanced packages allow to input and display data from multiple sensors or multiple annotators via intranet or internet. Posterior human-mediated annotation often include tools for data display and image analysis, e.g. length, area, image segmentation, point count; and in a few cases the possibility of browsing and editing previous dive logs or to analyze the annotations. The interaction with a database allows the automatic integration of annotations from different surveys, repeated annotation and collaborative annotation of shared datasets, browsing and querying of data. Progress in the field of automated annotation is mostly in post processing, for stable platforms or still images. Integration into available MIAS is currently limited to semi-automated processes of pixel recognition through computer-vision modules that compile expert-based knowledge. Important topics aiding the choice of a specific software are outlined, the ideal software is discussed and future trends are presented.

  1. Computer-aided diagnosis of HIE based on segmentation of MRI

    NASA Astrophysics Data System (ADS)

    Sun, Ziguang; Li, Chungui; Wang, Qin

    2009-10-01

    Computer-aided diagnosis has become one of the major research subjects in medical imaging and diagnostic radiology. Hypoxic-ischemic encephalopathy (HIE), remains a serious condition that causes significant mortality and long-term morbidity to neonates. We adopt self-organizing feature maps to segment the tissues, such as white matter and grey matter in the magnetic resonance images. The borderline between white matter and grey matter can be found and the doubtful regions along with the borderline can be localized, then the feature in doubtful regions can be quantified. The method can assist doctors to easily diagnose whether a neonate is ill with mild HIE.

  2. Implicit prosody mining based on the human eye image capture technology

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.

  3. The application of computer image analysis in life sciences and environmental engineering

    NASA Astrophysics Data System (ADS)

    Mazur, R.; Lewicki, A.; Przybył, K.; Zaborowicz, M.; Koszela, K.; Boniecki, P.; Mueller, W.; Raba, B.

    2014-04-01

    The main aim of the article was to present research on the application of computer image analysis in Life Science and Environmental Engineering. The authors used different methods of computer image analysis in developing of an innovative biotest in modern biomonitoring of water quality. Created tools were based on live organisms such as bioindicators Lemna minor L. and Hydra vulgaris Pallas as well as computer image analysis method in the assessment of negatives reactions during the exposition of the organisms to selected water toxicants. All of these methods belong to acute toxicity tests and are particularly essential in ecotoxicological assessment of water pollutants. Developed bioassays can be used not only in scientific research but are also applicable in environmental engineering and agriculture in the study of adverse effects on water quality of various compounds used in agriculture and industry.

  4. ESR/ERS white paper on lung cancer screening

    PubMed Central

    Bonomo, Lorenzo; Gaga, Mina; Nackaerts, Kristiaan; Peled, Nir; Prokop, Mathias; Remy-Jardin, Martine; von Stackelberg, Oyunbileg; Sculier, Jean-Paul

    2015-01-01

    Lung cancer is the most frequently fatal cancer, with poor survival once the disease is advanced. Annual low dose computed tomography has shown a survival benefit in screening individuals at high risk for lung cancer. Based on the available evidence, the European Society of Radiology and the European Respiratory Society recommend lung cancer screening in comprehensive, quality-assured, longitudinal programmes within a clinical trial or in routine clinical practice at certified multidisciplinary medical centres. Minimum requirements include: standardised operating procedures for low dose image acquisition, computer-assisted nodule evaluation, and positive screening results and their management; inclusion/exclusion criteria; expectation management; and smoking cessation programmes. Further refinements are recommended to increase quality, outcome and cost-effectiveness of lung cancer screening: inclusion of risk models, reduction of effective radiation dose, computer-assisted volumetric measurements and assessment of comorbidities (chronic obstructive pulmonary disease and vascular calcification). All these requirements should be adjusted to the regional infrastructure and healthcare system, in order to exactly define eligibility using a risk model, nodule management and quality assurance plan. The establishment of a central registry, including biobank and image bank, and preferably on a European level, is strongly encouraged. PMID:25929956

  5. [Scientometrics and bibliometrics of biomedical engineering periodicals and papers].

    PubMed

    Zhao, Ping; Xu, Ping; Li, Bingyan; Wang, Zhengrong

    2003-09-01

    This investigation was made to reveal the current status, research trend and research level of biomedical engineering in Chinese mainland by means of scientometrics and to assess the quality of the four domestic publications by bibliometrics. We identified all articles of four related publications by searching Chinese and foreign databases from 1997 to 2001. All articles collected or cited by these databases were searched and statistically analyzed for finding out the relevant distributions, including databases, years, authors, institutions, subject headings and subheadings. The source of sustentation funds and the related articles were analyzed too. The results showed that two journals were cited by two foreign databases and five Chinese databases simultaneously. The output of Journal of Biomedical Engineering was the highest. Its quantity of original papers cited by EI, CA and the totality of papers sponsored by funds were higher than those of the others, but the quantity and percentage per year of biomedical articles cited by EI were decreased in all. Inland core authors and institutions had come into being in the field of biomedical engineering. Their research topics were mainly concentrated on ten subject headings which included biocompatible materials, computer-assisted signal processing, electrocardiography, computer-assisted image processing, biomechanics, algorithms, electroencephalography, automatic data processing, mechanical stress, hemodynamics, mathematical computing, microcomputers, theoretical models, etc. The main subheadings were concentrated on instrumentation, physiopathology, diagnosis, therapy, ultrasonography, physiology, analysis, surgery, pathology, method, etc.

  6. [Application of image recognition technology in census of national traditional Chinese medicine resources].

    PubMed

    Zhang, Xiao-Bo; Ge, Xiao-Guang; Jin, Yan; Shi, Ting-Ting; Wang, Hui; Li, Meng; Jing, Zhi-Xian; Guo, Lan-Ping; Huang, Lu-Qi

    2017-11-01

    With the development of computer and image processing technology, image recognition technology has been applied to the national medicine resources census work at all stages.Among them: ①In the preparatory work, in order to establish a unified library of traditional Chinese medicine resources, using text recognition technology based on paper materials, be the assistant in the digitalization of various categories related to Chinese medicine resources; to determine the representative area and plots of the survey from each census team, based on the satellite remote sensing image and vegetation map and other basic data, using remote sensing image classification and other technical methods to assist in determining the key investigation area. ②In the process of field investigation, to obtain the planting area of Chinese herbal medicine was accurately, we use the decision tree model, spectral feature and object-oriented method were used to assist the regional identification and area estimation of Chinese medicinal materials.③In the process of finishing in the industry, in order to be able to relatively accurately determine the type of Chinese medicine resources in the region, based on the individual photos of the plant, the specimens and the name of the use of image recognition techniques, to assist the statistical summary of the types of traditional Chinese medicine resources. ④In the application of the results of transformation, based on the pharmaceutical resources and individual samples of medicinal herbs, the development of Chinese medicine resources to identify APP and authentic herbs 3D display system, assisted the identification of Chinese medicine resources and herbs identification characteristics. The introduction of image recognition technology in the census of Chinese medicine resources, assisting census personnel to carry out related work, not only can reduce the workload of the artificial, improve work efficiency, but also improve the census results of information technology and sharing application ability. With the deepening of the work of Chinese medicine resources census, image recognition technology in the relevant work will also play its unique role. Copyright© by the Chinese Pharmaceutical Association.

  7. Semi-automation of Doppler Spectrum Image Analysis for Grading Aortic Valve Stenosis Severity.

    PubMed

    Niakšu, O; Balčiunaitė, G; Kizlaitis, R J; Treigys, P

    2016-01-01

    Doppler echocardiography analysis has become a golden standard in the modern diagnosis of heart diseases. In this paper, we propose a set of techniques for semi-automated parameter extraction for aortic valve stenosis severity grading. The main objectives of the study is to create echocardiography image processing techniques, which minimize manual image processing work of clinicians and leads to reduced human error rates. Aortic valve and left ventricle output tract spectrogram images have been processed and analyzed. A novel method was developed to trace systoles and to extract diagnostic relevant features. The results of the introduced method have been compared to the findings of the participating cardiologists. The experimental results showed the accuracy of the proposed method is comparable to the manual measurement performed by medical professionals. Linear regression analysis of the calculated parameters and the measurements manually obtained by the cardiologists resulted in the strongly correlated values: peak systolic velocity's and mean pressure gradient's R2 both equal to 0.99, their means' differences equal to 0.02 m/s and 4.09 mmHg, respectively, and aortic valve area's R2 of 0.89 with the two methods means' difference of 0.19 mm. The introduced Doppler echocardiography images processing method can be used as a computer-aided assistance in the aortic valve stenosis diagnostics. In our future work, we intend to improve precision of left ventricular outflow tract spectrogram measurements and apply data mining methods to propose a clinical decision support system for diagnosing aortic valve stenosis.

  8. A Vision-Based Driver Nighttime Assistance and Surveillance System Based on Intelligent Image Sensing Techniques and a Heterogamous Dual-Core Embedded System Architecture

    PubMed Central

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system. PMID:22736956

  9. A vision-based driver nighttime assistance and surveillance system based on intelligent image sensing techniques and a heterogamous dual-core embedded system architecture.

    PubMed

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system.

  10. Plug-Assisted Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: The Role of Intra-Procedural Cone-Beam Computed Tomography

    PubMed Central

    Ko, Gi-Young; Kwon, Young Baek; Yoon, Hyun-Ki; Sung, Kyu-Bo

    2018-01-01

    Objective To investigate the technical and clinical outcomes of plug-assisted retrograde transvenous obliteration (PARTO) for the treatment of gastric varices (GV) and to evaluate the role of intra-procedural cone-beam computed tomography (CBCT) performed during PARTO to confirm its technical success. Materials and Methods From January 2016 to December 2016, 17 patients with GV who had undergone PARTO were retrospectively evaluated. When the proximal part of the afferent vein was identified on a fluoroscopy, non-contrast CBCT images were obtained. In patients with incomplete embolization of GV, an additional injection of gelatin sponges was performed. Follow-up data from contrast-enhanced CT and upper intestinal endoscopy, as well as clinical and laboratory data were collected. Results Plug-assisted retrograde transvenous obliteration procedures were technically successful in all 17 patients. Complete embolization of GV was detected on CBCT images in 15 patients; whereas, incomplete embolization was detected in two. Complete embolization of GV was then achieved after an additional injection of gelatin sponges in these two patients as demonstrated on the 2nd CBCT image. The mean follow-up period after PARTO was 193 days (range, 73–383 days). A follow-up CT obtained 2–4 months after PARTO demonstrated marked shrinkage or complete obliteration of GV and portosystemic shunts in all 17 patients. There were no cases of variceal bleeding during the follow-up. Conclusion Plug-assisted retrograde transvenous obliteration is technically and clinically effective for the treatment of GV. In addition, intra-procedural CBCT can be an adjunct tool to fluoroscopy, because it can provide an immediate and accurate evaluation of the technical success of PARTO. PMID:29520179

  11. Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement.

    PubMed

    Dong, Hengjin; Buxton, Martin

    2006-01-01

    The objective of this study is to apply a Markov model to compare cost-effectiveness of total knee replacement (TKR) using computer-assisted surgery (CAS) with that of TKR using a conventional manual method in the absence of formal clinical trial evidence. A structured search was carried out to identify evidence relating to the clinical outcome, cost, and effectiveness of TKR. Nine Markov states were identified based on the progress of the disease after TKR. Effectiveness was expressed by quality-adjusted life years (QALYs). The simulation was carried out initially for 120 cycles of a month each, starting with 1,000 TKRs. A discount rate of 3.5 percent was used for both cost and effectiveness in the incremental cost-effectiveness analysis. Then, a probabilistic sensitivity analysis was carried out using a Monte Carlo approach with 10,000 iterations. Computer-assisted TKR was a long-term cost-effective technology, but the QALYs gained were small. After the first 2 years, the incremental cost per QALY of computer-assisted TKR was dominant because of cheaper and more QALYs. The incremental cost-effectiveness ratio (ICER) was sensitive to the "effect of CAS," to the CAS extra cost, and to the utility of the state "Normal health after primary TKR," but it was not sensitive to utilities of other Markov states. Both probabilistic and deterministic analyses produced similar cumulative serious or minor complication rates and complex or simple revision rates. They also produced similar ICERs. Compared with conventional TKR, computer-assisted TKR is a cost-saving technology in the long-term and may offer small additional QALYs. The "effect of CAS" is to reduce revision rates and complications through more accurate and precise alignment, and although the conclusions from the model, even when allowing for a full probabilistic analysis of uncertainty, are clear, the "effect of CAS" on the rate of revisions awaits long-term clinical evidence.

  12. Medical Student Preferences for Self-Directed Study Resources in Gross Anatomy

    ERIC Educational Resources Information Center

    Choi-Lundberg, Derek L.; Low, Tze Feng; Patman, Phillip; Turner, Paul; Sinha, Sankar N.

    2016-01-01

    Gross anatomy instruction in medical curricula involve a range of resources and activities including dissection, prosected specimens, anatomical models, radiological images, surface anatomy, textbooks, atlases, and computer-assisted learning (CAL). These resources and activities are underpinned by the expectation that students will actively engage…

  13. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    PubMed

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  14. Computer analysis of arteriograms

    NASA Technical Reports Server (NTRS)

    Selzer, R. H.; Armstrong, J. H.; Beckenbach, E. B.; Blankenhorn, D. H.; Crawford, D. W.; Brooks, S. H.; Sanmarco, M. E.

    1977-01-01

    A computer system has been developed to quantify the degree of atherosclerosis in the human femoral artery. The analysis involves first scanning and digitizing angiographic film, then tracking the outline of the arterial image and finally computing the relative amount of roughness or irregularity in the vessel wall. The image processing system and method are described.

  15. Influence of the quality of intraoperative fluoroscopic images on the spatial positioning accuracy of a CAOS system.

    PubMed

    Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo

    2018-06-01

    Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.

  16. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    PubMed

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  17. The Effects of Computer-Assisted Instruction Based on Top-Level Structure Method in English Reading and Writing Abilities of Thai EFL Students

    ERIC Educational Resources Information Center

    Jinajai, Nattapong; Rattanavich, Saowalak

    2015-01-01

    This research aims to study the development of ninth grade students' reading and writing abilities and interests in learning English taught through computer-assisted instruction (CAI) based on the top-level structure (TLS) method. An experimental group time series design was used, and the data was analyzed by multivariate analysis of variance…

  18. A Differential Feature-Cost Analysis of Fifteen Computer-Assisted Career Guidance Systems: Technical Report Number 10. (Fourth Edition).

    ERIC Educational Resources Information Center

    Sampson, James P., Jr.; And Others

    This study examined similarities and differences among 15 computer-assisted career guidance (CACG) systems: (1) the Career Information System; (2) Choices; (3) Choices CT; (4) Choices Jr; (5) MODULAR C-LECT; (6) COIN; (7) COIN Jr; (8) DISCOVER for Colleges and Adults; (9) DISCOVER for High Schools; (10) DISCOVER for Junior High and Middle Schools;…

  19. Computer-assisted quantification of the skull deformity for craniosynostosis from 3D head CT images using morphological descriptor and hierarchical classification

    NASA Astrophysics Data System (ADS)

    Lee, Min Jin; Hong, Helen; Shim, Kyu Won; Kim, Yong Oock

    2017-03-01

    This paper proposes morphological descriptors representing the degree of skull deformity for craniosynostosis in head CT images and a hierarchical classifier model distinguishing among normal and different types of craniosynostosis. First, to compare deformity surface model with mean normal surface model, mean normal surface models are generated for each age range and the mean normal surface model is deformed to the deformity surface model via multi-level threestage registration. Second, four shape features including local distance and area ratio indices are extracted in each five cranial bone. Finally, hierarchical SVM classifier is proposed to distinguish between the normal and deformity. As a result, the proposed method showed improved classification results compared to traditional cranial index. Our method can be used for the early diagnosis, surgical planning and postsurgical assessment of craniosynostosis as well as quantitative analysis of skull deformity.

  20. Improving Situational Awareness for First Responders via Mobile Computing

    NASA Technical Reports Server (NTRS)

    Betts, Bradley J.; Mah, Robert W.; Papasin, Richard; Del Mundo, Rommel; McIntosh, Dawn M.; Jorgensen, Charles

    2005-01-01

    This project looks to improve first responder situational awareness using tools and techniques of mobile computing. The prototype system combines wireless communication, real-time location determination, digital imaging, and three-dimensional graphics. Responder locations are tracked in an outdoor environment via GPS and uploaded to a central server via GPRS or an 802.11 network. Responders can also wirelessly share digital images and text reports, both with other responders and with the incident commander. A pre-built three dimensional graphics model of a particular emergency scene is used to visualize responder and report locations. Responders have a choice of information end points, ranging from programmable cellular phones to tablet computers. The system also employs location-aware computing to make responders aware of particular hazards as they approach them. The prototype was developed in conjunction with the NASA Ames Disaster Assistance and Rescue Team and has undergone field testing during responder exercise at NASA Ames.

  1. Improving Situational Awareness for First Responders via Mobile Computing

    NASA Technical Reports Server (NTRS)

    Betts, Bradley J.; Mah, Robert W.; Papasin, Richard; Del Mundo, Rommel; McIntosh, Dawn M.; Jorgensen, Charles

    2006-01-01

    This project looks to improve first responder incident command, and an appropriately managed flow of situational awareness using mobile computing techniques. The prototype system combines wireless communication, real-time location determination, digital imaging, and three-dimensional graphics. Responder locations are tracked in an outdoor environment via GPS and uploaded to a central server via GPRS or an 802. II network. Responders can also wireless share digital images and text reports, both with other responders and with the incident commander. A pre-built three dimensional graphics model of the emergency scene is used to visualize responder and report locations. Responders have a choice of information end points, ranging from programmable cellular phones to tablet computers. The system also employs location-aware computing to make responders aware of particular hazards as they approach them. The prototype was developed in conjunction with the NASA Ames Disaster Assistance and Rescue Team and has undergone field testing during responder exercises at NASA Ames.

  2. Computer and Software Use in Teaching the Beginning Statistics Course.

    ERIC Educational Resources Information Center

    Bartz, Albert E.; Sabolik, Marisa A.

    2001-01-01

    Surveys the extent of computer usage in the beginning statistics course and the variety of statistics software used. Finds that 69% of the psychology departments used computers in beginning statistics courses and 90% used computer-assisted data analysis in statistics or other courses. (CMK)

  3. Development and evaluation of a hand tracker using depth images captured from an overhead perspective.

    PubMed

    Czarnuch, Stephen; Mihailidis, Alex

    2015-03-27

    We present the development and evaluation of a robust hand tracker based on single overhead depth images for use in the COACH, an assistive technology for people with dementia. The new hand tracker was designed to overcome limitations experienced by the COACH in previous clinical trials. We train a random decision forest classifier using ∼5000 manually labeled, unbalanced, training images. Hand positions from the classifier are translated into task actions based on proximity to environmental objects. Tracker performance is evaluated using a large set of ∼24 000 manually labeled images captured from 41 participants in a fully-functional washroom, and compared to the system's previous colour-based hand tracker. Precision and recall were 0.994 and 0.938 for the depth tracker compared to 0.981 and 0.822 for the colour tracker with the current data, and 0.989 and 0.466 in the previous study. The improved tracking performance supports integration of the depth-based tracker into the COACH toward unsupervised, real-world trials. Implications for Rehabilitation The COACH is an intelligent assistive technology that can enable people with cognitive disabilities to stay at home longer, supporting the concept of aging-in-place. Automated prompting systems, a type of intelligent assistive technology, can help to support the independent completion of activities of daily living, increasing the independence of people with cognitive disabilities while reducing the burden of care experienced by caregivers. Robust motion tracking using depth imaging supports the development of intelligent assistive technologies like the COACH. Robust motion tracking also has application to other forms of assistive technologies including gaming, human-computer interaction and automated assessments.

  4. Quantifying Digital Ulcers in Systemic Sclerosis: Reliability of Computer-Assisted Planimetry in Measuring Lesion Size.

    PubMed

    Simpson, V; Hughes, M; Wilkinson, J; Herrick, A L; Dinsdale, G

    2018-03-01

    Digital ulcers are a major problem in patients with systemic sclerosis (SSc), causing severe pain and impairment of hand function. In addition, digital ulcers heal slowly and sometimes become infected, which can lead to gangrene and necessitate amputation if appropriate intervention is not taken. A reliable, objective method for assessing digital ulcer healing or progression is needed in both the clinical and research arenas. This study was undertaken to compare 2 computer-assisted planimetry methods of measurement of digital ulcer area on photographs (ellipse and freehand regions of interest [ROIs]), and to assess the reliability of photographic calibration and the 2 methods of area measurement. Photographs were taken of 107 digital ulcers in 36 patients with SSc spectrum disease. Three raters assessed the photographs. Custom software allowed raters to calibrate photograph dimensions and draw ellipse or freehand ROIs. The shapes and dimensions of the ROIs were saved for further analysis. Calibration (by a single rater performing 5 repeats per image) produced an intraclass correlation coefficient (intrarater reliability) of 0.99. The mean ± SD areas of digital ulcers assessed using ellipse and freehand ROIs were 18.7 ± 20.2 mm 2 and 17.6 ± 19.3 mm 2 , respectively. Intrarater and interrater reliability of the ellipse ROI were 0.97 and 0.77, respectively. For the freehand ROI, the intrarater and interrater reliability were 0.98 and 0.76, respectively. Our findings indicate that computer-assisted planimetry methods applied to SSc-related digital ulcers can be extremely reliable. Further work is needed to move toward applying these methods as outcome measures for clinical trials and in clinical settings. © 2017, American College of Rheumatology.

  5. Multiparticle imaging technique for two-phase fluid flows using pulsed laser speckle velocimetry. Final report, September 1988--November 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassan, T.A.

    1992-12-01

    The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows.more » A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.« less

  6. Multiparticle imaging technique for two-phase fluid flows using pulsed laser speckle velocimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassan, T.A.

    1992-12-01

    The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows.more » A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.« less

  7. Assistive lesion-emphasis system: an assistive system for fundus image readers

    PubMed Central

    Rangrej, Samrudhdhi B.; Sivaswamy, Jayanthi

    2017-01-01

    Abstract. Computer-assisted diagnostic (CAD) tools are of interest as they enable efficient decision-making in clinics and the screening of diseases. The traditional approach to CAD algorithm design focuses on the automated detection of abnormalities independent of the end-user, who can be an image reader or an expert. We propose a reader-centric system design wherein a reader’s attention is drawn to abnormal regions in a least-obtrusive yet effective manner, using saliency-based emphasis of abnormalities and without altering the appearance of the background tissues. We present an assistive lesion-emphasis system (ALES) based on the above idea, for fundus image-based diabetic retinopathy diagnosis. Lesion-saliency is learnt using a convolutional neural network (CNN), inspired by the saliency model of Itti and Koch. The CNN is used to fine-tune standard low-level filters and learn high-level filters for deriving a lesion-saliency map, which is then used to perform lesion-emphasis via a spatially variant version of gamma correction. The proposed system has been evaluated on public datasets and benchmarked against other saliency models. It was found to outperform other saliency models by 6% to 30% and boost the contrast-to-noise ratio of lesions by more than 30%. Results of a perceptual study also underscore the effectiveness and, hence, the potential of ALES as an assistive tool for readers. PMID:28560245

  8. Detection, modeling and matching of pleural thickenings from CT data towards an early diagnosis of malignant pleural mesothelioma

    NASA Astrophysics Data System (ADS)

    Chaisaowong, Kraisorn; Kraus, Thomas

    2014-03-01

    Pleural thickenings can be caused by asbestos exposure and may evolve into malignant pleural mesothelioma. While an early diagnosis plays the key role to an early treatment, and therefore helping to reduce morbidity, the growth rate of a pleural thickening can be in turn essential evidence to an early diagnosis of the pleural mesothelioma. The detection of pleural thickenings is today done by a visual inspection of CT data, which is time-consuming and underlies the physician's subjective judgment. Computer-assisted diagnosis systems to automatically assess pleural mesothelioma have been reported worldwide. But in this paper, an image analysis pipeline to automatically detect pleural thickenings and measure their volume is described. We first delineate automatically the pleural contour in the CT images. An adaptive surface-base smoothing technique is then applied to the pleural contours to identify all potential thickenings. A following tissue-specific topology-oriented detection based on a probabilistic Hounsfield Unit model of pleural plaques specify then the genuine pleural thickenings among them. The assessment of the detected pleural thickenings is based on the volumetry of the 3D model, created by mesh construction algorithm followed by Laplace-Beltrami eigenfunction expansion surface smoothing technique. Finally, the spatiotemporal matching of pleural thickenings from consecutive CT data is carried out based on the semi-automatic lung registration towards the assessment of its growth rate. With these methods, a new computer-assisted diagnosis system is presented in order to assure a precise and reproducible assessment of pleural thickenings towards the diagnosis of the pleural mesothelioma in its early stage.

  9. Computer-assisted analysis of the vascular endothelial cell motile response to injury.

    PubMed

    Askey, D B; Herman, I M

    1988-12-01

    We have developed an automated, user-friendly method to track vascular endothelial cell migration in vitro using an IBM PC/XT with MS DOS. Analog phase-contrast images of the bovine aortic endothelial cells are converted into digital images (8 bit, 250 x 240 pixel resolution) using a Tecmar Video VanGogh A/D board. Digitized images are stored at selected time points following mechanical injury in vitro. FORTRAN and assembly language subroutines have been implemented to automatically detect the wound edge and the edge of each cell nucleus in the phase-contrast, light-microscope field. Detection of the wound edge is accomplished by intensity thresholding following noise reduction in the image and subsequent sampling of the wound. After the range of wound intensities is determined, the entire image is sampled and a histogram of intensities is formed. The histogram peak corresponding to the wound intensities is subtracted, leaving a histogram peak that gives the range of intensities corresponding to the cell nuclei. Rates of cell migration, as well as cellular trajectories and cell surface areas, can be automatically quantitated and analyzed. This inexpensive, automated cell-tracking system should be widely applicable in a variety of cell biologic applications.

  10. Science Activity Planner for the MER Mission

    NASA Technical Reports Server (NTRS)

    Norris, Jeffrey S.; Crockett, Thomas M.; Fox, Jason M.; Joswig, Joseph C.; Powell, Mark W.; Shams, Khawaja S.; Torres, Recaredo J.; Wallick, Michael N.; Mittman, David S.

    2008-01-01

    The Maestro Science Activity Planner is a computer program that assists human users in planning operations of the Mars Explorer Rover (MER) mission and visualizing scientific data returned from the MER rovers. Relative to its predecessors, this program is more powerful and easier to use. This program is built on the Java Eclipse open-source platform around a Web-browser-based user-interface paradigm to provide an intuitive user interface to Mars rovers and landers. This program affords a combination of advanced display and simulation capabilities. For example, a map view of terrain can be generated from images acquired by the High Resolution Imaging Science Explorer instrument aboard the Mars Reconnaissance Orbiter spacecraft and overlaid with images from a navigation camera (more precisely, a stereoscopic pair of cameras) aboard a rover, and an interactive, annotated rover traverse path can be incorporated into the overlay. It is also possible to construct an overhead perspective mosaic image of terrain from navigation-camera images. This program can be adapted to similar use on other outer-space missions and is potentially adaptable to numerous terrestrial applications involving analysis of data, operations of robots, and planning of such operations for acquisition of scientific data.

  11. [Expert systems and automatic diagnostic systems in histopathology--a review].

    PubMed

    Tamai, S

    1999-02-01

    In this decade, the pathological information system has gradually been settled in many hospitals in Japan. Pathological reports and images are now digitized and managed in the database, and are referred by clinicians at the peripherals. Tele-pathology is also developing; and its users are increasing. However, in many occasions, the problem solving in diagnostic pathology is completely dependent on the solo-pathologist. Considering the need for timely and efficient supports to the solo-pathologist, I reviewed the papers on the knowledge-based interactive expert systems. The interpretations of the histopathological images are dependent on the pathologist, and these expert systems have been evaluated as "educational". With the view of the success in the cytological screening, the development of "image-analysis-based" automatic "histopathological image" classifier has been on ongoing challenges. Our 3 years experience of the development of the pathological image classifier using the artificial neural networks technology is briefly presented. This classifier provides us a "fitting rate" for the individual diagnostic pattern of the breast tumors, such as "fibroadenoma pattern". The diagnosis assisting system with computer technology should provide pathologists, especially solo-pathologists, a useful tool for the quality assurance and improvement of pathological diagnosis.

  12. Enhancing image classification models with multi-modal biomarkers

    NASA Astrophysics Data System (ADS)

    Caban, Jesus J.; Liao, David; Yao, Jianhua; Mollura, Daniel J.; Gochuico, Bernadette; Yoo, Terry

    2011-03-01

    Currently, most computer-aided diagnosis (CAD) systems rely on image analysis and statistical models to diagnose, quantify, and monitor the progression of a particular disease. In general, CAD systems have proven to be effective at providing quantitative measurements and assisting physicians during the decision-making process. As the need for more flexible and effective CADs continues to grow, questions about how to enhance their accuracy have surged. In this paper, we show how statistical image models can be augmented with multi-modal physiological values to create more robust, stable, and accurate CAD systems. In particular, this paper demonstrates how highly correlated blood and EKG features can be treated as biomarkers and used to enhance image classification models designed to automatically score subjects with pulmonary fibrosis. In our results, a 3-5% improvement was observed when comparing the accuracy of CADs that use multi-modal biomarkers with those that only used image features. Our results show that lab values such as Erythrocyte Sedimentation Rate and Fibrinogen, as well as EKG measurements such as QRS and I:40, are statistically significant and can provide valuable insights about the severity of the pulmonary fibrosis disease.

  13. Semiautomatic tumor segmentation with multimodal images in a conditional random field framework.

    PubMed

    Hu, Yu-Chi; Grossberg, Michael; Mageras, Gikas

    2016-04-01

    Volumetric medical images of a single subject can be acquired using different imaging modalities, such as computed tomography, magnetic resonance imaging (MRI), and positron emission tomography. In this work, we present a semiautomatic segmentation algorithm that can leverage the synergies between different image modalities while integrating interactive human guidance. The algorithm provides a statistical segmentation framework partly automating the segmentation task while still maintaining critical human oversight. The statistical models presented are trained interactively using simple brush strokes to indicate tumor and nontumor tissues and using intermediate results within a patient's image study. To accomplish the segmentation, we construct the energy function in the conditional random field (CRF) framework. For each slice, the energy function is set using the estimated probabilities from both user brush stroke data and prior approved segmented slices within a patient study. The progressive segmentation is obtained using a graph-cut-based minimization. Although no similar semiautomated algorithm is currently available, we evaluated our method with an MRI data set from Medical Image Computing and Computer Assisted Intervention Society multimodal brain segmentation challenge (BRATS 2012 and 2013) against a similar fully automatic method based on CRF and a semiautomatic method based on grow-cut, and our method shows superior performance.

  14. Application of computer assisted moire to the study of a crack tip

    NASA Astrophysics Data System (ADS)

    Sciammarella, C. A.; Albertazzi, A., Jr.; Mourikes, J.

    The basic principles of computer assisted moire are discussed. The influence of the image sensor and its finite dimensions on the sampling theorem requirements is discussed. Criteria for the selection of grating pitch on the basis of the spatial bandwidth of the pattern to be observed and the requirements arising from sensitivity considerations are given. The method is used to analyze the strain field in the neighborhood of the crack tip of a standard ASTM compact tension specimen. From the displacements the strains are computed, and from the strains the stresses are obtained using the generalized Ramberg-Osgood stress strain relationship. The stresses are used to compute the values for the J-integral in several circuits surrounding the crack. Good agreement is obtained between the values of the stress intensity factors obtained by different methods. The plastic region surrounding the crack does not show a HRR field and thus the usual rationale to justify the J-integral methods must be re-evaluated.

  15. Otitis Media Diagnosis for Developing Countries Using Tympanic Membrane Image-Analysis.

    PubMed

    Myburgh, Hermanus C; van Zijl, Willemien H; Swanepoel, DeWet; Hellström, Sten; Laurent, Claude

    2016-03-01

    Otitis media is one of the most common childhood diseases worldwide, but because of lack of doctors and health personnel in developing countries it is often misdiagnosed or not diagnosed at all. This may lead to serious, and life-threatening complications. There is, thus a need for an automated computer based image-analyzing system that could assist in making accurate otitis media diagnoses anywhere. A method for automated diagnosis of otitis media is proposed. The method uses image-processing techniques to classify otitis media. The system is trained using high quality pre-assessed images of tympanic membranes, captured by digital video-otoscopes, and classifies undiagnosed images into five otitis media categories based on predefined signs. Several verification tests analyzed the classification capability of the method. An accuracy of 80.6% was achieved for images taken with commercial video-otoscopes, while an accuracy of 78.7% was achieved for images captured on-site with a low cost custom-made video-otoscope. The high accuracy of the proposed otitis media classification system compares well with the classification accuracy of general practitioners and pediatricians (~64% to 80%) using traditional otoscopes, and therefore holds promise for the future in making automated diagnosis of otitis media in medically underserved populations.

  16. Otitis Media Diagnosis for Developing Countries Using Tympanic Membrane Image-Analysis

    PubMed Central

    Myburgh, Hermanus C.; van Zijl, Willemien H.; Swanepoel, DeWet; Hellström, Sten; Laurent, Claude

    2016-01-01

    Background Otitis media is one of the most common childhood diseases worldwide, but because of lack of doctors and health personnel in developing countries it is often misdiagnosed or not diagnosed at all. This may lead to serious, and life-threatening complications. There is, thus a need for an automated computer based image-analyzing system that could assist in making accurate otitis media diagnoses anywhere. Methods A method for automated diagnosis of otitis media is proposed. The method uses image-processing techniques to classify otitis media. The system is trained using high quality pre-assessed images of tympanic membranes, captured by digital video-otoscopes, and classifies undiagnosed images into five otitis media categories based on predefined signs. Several verification tests analyzed the classification capability of the method. Findings An accuracy of 80.6% was achieved for images taken with commercial video-otoscopes, while an accuracy of 78.7% was achieved for images captured on-site with a low cost custom-made video-otoscope. Interpretation The high accuracy of the proposed otitis media classification system compares well with the classification accuracy of general practitioners and pediatricians (~ 64% to 80%) using traditional otoscopes, and therefore holds promise for the future in making automated diagnosis of otitis media in medically underserved populations. PMID:27077122

  17. Interpretative Guidelines and Possible Indications for Indocyanine Green Fluorescence Imaging in Robot-Assisted Sphincter-Saving Operations.

    PubMed

    Kim, Jin Cheon; Lee, Jong Lyul; Park, Seong Ho

    2017-04-01

    Since the introduction of indocyanine green angiography more than 25 years ago, few studies have presented interpretative guidelines for indocyanine green fluorescent imaging. We aimed to provide interpretative guidelines for indocyanine green fluorescent imaging through quantitative analysis and to suggest possible indications for indocyanine green fluorescent imaging during robot-assisted sphincter-saving operations. This is a retrospective observational study. This study was conducted at a single center. A cohort of 657 patients with rectal cancer who consecutively underwent curative robot-assisted sphincter-saving operations was enrolled between 2010 and 2016, including 310 patients with indocyanine green imaging (indocyanine green fluorescent imaging+ group) and 347 patients without indocyanine green imaging (indocyanine green fluorescent imaging- group). We tried to quantitatively define the indocyanine green fluorescent imaging findings based on perfusion (mesocolic and colic) time and perfusion intensity (5 grades) to provide probable indications. The anastomotic leakage rate was significantly lower in the indocyanine green fluorescent imaging+ group than in the indocyanine green fluorescent imaging- group (0.6% vs 5.2%) (OR, 0.123; 95% CI, 0.028-0.544; p = 0.006). Anastomotic stricture was closely correlated with anastomotic leakage (p = 0.002) and a short descending mesocolon (p = 0.003). Delayed perfusion (>60 s) and low perfusion intensity (1-2) were more frequently detected in patients with anastomotic stricture and marginal artery defects than in those without these factors (p ≤ 0.001). In addition, perfusion times greater than the mean were more frequently observed in patients aged >58 years, whereas low perfusion intensity was seen more in patients with short descending mesocolon and high ASA classes (≥3). The 300 patients in the indocyanine green fluorescent imaging- group underwent operations 3 years before indocyanine green fluorescent imaging. Quantitative analysis of indocyanine green fluorescent imaging may help prevent anastomotic complications during robot-assisted sphincter-saving operations, and may be of particular value in high-class ASA patients, older patients, and patients with a short descending mesocolon.

  18. Mass spectrometry imaging for visualizing organic analytes in food.

    PubMed

    Handberg, Eric; Chingin, Konstantin; Wang, Nannan; Dai, Ximo; Chen, Huanwen

    2015-01-01

    The demand for rapid chemical imaging of food products steadily increases. Mass spectrometry (MS) is featured by excellent molecular specificity of analysis and is, therefore, a very attractive method for chemical profiling. MS for food imaging has increased significantly over the past decade, aided by the emergence of various ambient ionization techniques that allow direct and rapid analysis in ambient environment. In this article, the current status of food imaging with MSI is reviewed. The described approaches include matrix-assisted laser desorption/ionization (MALDI), but emphasize desorption atmospheric pressure photoionization (DAPPI), electrospray-assisted laser desorption/ionization (ELDI), probe electrospray ionization (PESI), surface desorption atmospheric pressure chemical ionization (SDAPCI), and laser ablation flowing atmospheric pressure afterglow (LA-FAPA). The methods are compared with regard to spatial resolution; analysis speed and time; limit of detection; and technical aspects. The performance of each method is illustrated with the description of a related application. Specific requirements in food imaging are discussed. © 2014 Wiley Periodicals, Inc.

  19. Artificial intelligence in medicine and cardiac imaging: harnessing big data and advanced computing to provide personalized medical diagnosis and treatment.

    PubMed

    Dilsizian, Steven E; Siegel, Eliot L

    2014-01-01

    Although advances in information technology in the past decade have come in quantum leaps in nearly every aspect of our lives, they seem to be coming at a slower pace in the field of medicine. However, the implementation of electronic health records (EHR) in hospitals is increasing rapidly, accelerated by the meaningful use initiatives associated with the Center for Medicare & Medicaid Services EHR Incentive Programs. The transition to electronic medical records and availability of patient data has been associated with increases in the volume and complexity of patient information, as well as an increase in medical alerts, with resulting "alert fatigue" and increased expectations for rapid and accurate diagnosis and treatment. Unfortunately, these increased demands on health care providers create greater risk for diagnostic and therapeutic errors. In the near future, artificial intelligence (AI)/machine learning will likely assist physicians with differential diagnosis of disease, treatment options suggestions, and recommendations, and, in the case of medical imaging, with cues in image interpretation. Mining and advanced analysis of "big data" in health care provide the potential not only to perform "in silico" research but also to provide "real time" diagnostic and (potentially) therapeutic recommendations based on empirical data. "On demand" access to high-performance computing and large health care databases will support and sustain our ability to achieve personalized medicine. The IBM Jeopardy! Challenge, which pitted the best all-time human players against the Watson computer, captured the imagination of millions of people across the world and demonstrated the potential to apply AI approaches to a wide variety of subject matter, including medicine. The combination of AI, big data, and massively parallel computing offers the potential to create a revolutionary way of practicing evidence-based, personalized medicine.

  20. Toward computer-assisted image-guided congenital heart defect repair: an initial phantom analysis.

    PubMed

    Kwartowitz, David M; Mefleh, Fuad N; Baker, G Hamilton

    2017-10-01

    Radiation exposure in interventional cardiology is an important consideration, due to risk of cancer and other morbidity to the patient and clinical staff. Cardiac catheterizations rely heavily on fluoroscopic imaging exposing both patient and clinician to ionizing radiation. An image-guided surgery system capable of facilitating cardiac catheterizations was developed and tested to evaluate dose reduction. Several electromagnetically tracked tools were constructed specifically a 7-Fr catheter with five 5-degree-of-freedom magnetic seeds. Catheter guidance was accomplished using our image guidance system Kit for Navigation by Image-Focused Exploration and fluoroscopy alone. A cardiac phantom was designed and 3D printed to validate the image guidance procedure. In mock procedures, an expert clinician guided and deployed an occluder across the septal defect of the phantom heart. The image guidance method resulted in a dose of 1.26 mSv of radiation dose per procedure, while traditional guidance resulted in a dose of 3.33 mSv. Average overall dose savings for the image-guided method was nearly 2.07 mSv or 62 %. The work showed significant ([Formula: see text]) decrease in radiation dose with use of image guidance methods at the expense of a modest increase in procedure time. This study lays the groundwork for further exploration of image guidance applications in pediatric cardiology.

  1. 3D volumetry comparison using 3T magnetic resonance imaging between normal and adenoma-containing pituitary glands.

    PubMed

    Roldan-Valadez, Ernesto; Garcia-Ulloa, Ana Cristina; Gonzalez-Gutierrez, Omar; Martinez-Lopez, Manuel

    2011-01-01

    Computed-assisted three-dimensional data (3D) allows for an accurate evaluation of volumes compared with traditional measurements. An in vitro method comparison between geometric volume and 3D volumetry to obtain reference data for pituitary volumes in normal pituitary glands (PGs) and PGs containing adenomas. Prospective, transverse, analytical study. Forty-eight subjects underwent brain magnetic resonance imaging (MRI) with 3D sequencing for computer-aided volumetry. PG phantom volumes by both methods were compared. Using the best volumetric method, volumes of normal PGs and PGs with adenoma were compared. Statistical analysis used the Bland-Altman method, t-statistics, effect size and linear regression analysis. Method comparison between 3D volumetry and geometric volume revealed a lower bias and precision for 3D volumetry. A total of 27 patients exhibited normal PGs (mean age, 42.07 ± 16.17 years), although length, height, width, geometric volume and 3D volumetry were greater in women than in men. A total of 21 patients exhibited adenomas (mean age 39.62 ± 10.79 years), and length, height, width, geometric volume and 3D volumetry were greater in men than in women, with significant volumetric differences. Age did not influence pituitary volumes on linear regression analysis. Results from the present study showed that 3D volumetry was more accurate than the geometric method. In addition, the upper normal limits of PGs overlapped with lower volume limits during early stage microadenomas.

  2. Event-based image recognition applied in tennis training assistance

    NASA Astrophysics Data System (ADS)

    Wawrzyniak, Zbigniew M.; Kowalski, Adam

    2016-09-01

    This paper presents a concept of a real-time system for individual tennis training assistance. The system is supposed to provide user (player) with information on his strokes accuracy as well as other training quality parameters such as velocity and rotation of the ball during its flight. The method is based on image processing methods equipped with developed explorative analysis of the events and their description by parameters of the movement. There has been presented the concept for further deployment to create a complete system that could assist tennis player during individual training.

  3. Neuroimaging of epilepsy

    PubMed Central

    Cendes, Fernando; Theodore, William H.; Brinkmann, Benjamin H.; Sulc, Vlastimil; Cascino, Gregory D.

    2017-01-01

    Imaging is pivotal in the evaluation and management of patients with seizure disorders. Elegant structural neuroimaging with magnetic resonance imaging (MRI) may assist in determining the etiology of focal epilepsy and demonstrating the anatomical changes associated with seizure activity. The high diagnostic yield of MRI to identify the common pathological findings in individuals with focal seizures including mesial temporal sclerosis, vascular anomalies, low-grade glial neoplasms and malformations of cortical development has been demonstrated. Positron emission tomography (PET) is the most commonly performed interictal functional neuroimaging technique that may reveal a focal hypometabolic region concordant with seizure onset. Single photon emission computed tomography (SPECT) studies may assist performance of ictal neuroimaging in patients with pharmacoresistant focal epilepsy being considered for neurosurgical treatment. This chapter highlights neuroimaging developments and innovations, and provides a comprehensive overview of the imaging strategies used to improve the care and management of people with epilepsy. PMID:27430454

  4. A Parallel Point Matching Algorithm for Landmark Based Image Registration Using Multicore Platform

    PubMed Central

    Yang, Lin; Gong, Leiguang; Zhang, Hong; Nosher, John L.; Foran, David J.

    2013-01-01

    Point matching is crucial for many computer vision applications. Establishing the correspondence between a large number of data points is a computationally intensive process. Some point matching related applications, such as medical image registration, require real time or near real time performance if applied to critical clinical applications like image assisted surgery. In this paper, we report a new multicore platform based parallel algorithm for fast point matching in the context of landmark based medical image registration. We introduced a non-regular data partition algorithm which utilizes the K-means clustering algorithm to group the landmarks based on the number of available processing cores, which optimize the memory usage and data transfer. We have tested our method using the IBM Cell Broadband Engine (Cell/B.E.) platform. The results demonstrated a significant speed up over its sequential implementation. The proposed data partition and parallelization algorithm, though tested only on one multicore platform, is generic by its design. Therefore the parallel algorithm can be extended to other computing platforms, as well as other point matching related applications. PMID:24308014

  5. The evaluation of alternate methodologies for land cover classification in an urbanizing area

    NASA Technical Reports Server (NTRS)

    Smekofski, R. M.

    1981-01-01

    The usefulness of LANDSAT in classifying land cover and in identifying and classifying land use change was investigated using an urbanizing area as the study area. The question of what was the best technique for classification was the primary focus of the study. The many computer-assisted techniques available to analyze LANDSAT data were evaluated. Techniques of statistical training (polygons from CRT, unsupervised clustering, polygons from digitizer and binary masks) were tested with minimum distance to the mean, maximum likelihood and canonical analysis with minimum distance to the mean classifiers. The twelve output images were compared to photointerpreted samples, ground verified samples and a current land use data base. Results indicate that for a reconnaissance inventory, the unsupervised training with canonical analysis-minimum distance classifier is the most efficient. If more detailed ground truth and ground verification is available, the polygons from the digitizer training with the canonical analysis minimum distance is more accurate.

  6. Computer-assisted surgery: virtual- and augmented-reality displays for navigation during urological interventions.

    PubMed

    van Oosterom, Matthias N; van der Poel, Henk G; Navab, Nassir; van de Velde, Cornelis J H; van Leeuwen, Fijs W B

    2018-03-01

    To provide an overview of the developments made for virtual- and augmented-reality navigation procedures in urological interventions/surgery. Navigation efforts have demonstrated potential in the field of urology by supporting guidance for various disorders. The navigation approaches differ between the individual indications, but seem interchangeable to a certain extent. An increasing number of pre- and intra-operative imaging modalities has been used to create detailed surgical roadmaps, namely: (cone-beam) computed tomography, MRI, ultrasound, and single-photon emission computed tomography. Registration of these surgical roadmaps with the real-life surgical view has occurred in different forms (e.g. electromagnetic, mechanical, vision, or near-infrared optical-based), whereby the combination of approaches was suggested to provide superior outcome. Soft-tissue deformations demand the use of confirmatory interventional (imaging) modalities. This has resulted in the introduction of new intraoperative modalities such as drop-in US, transurethral US, (drop-in) gamma probes and fluorescence cameras. These noninvasive modalities provide an alternative to invasive technologies that expose the patients to X-ray doses. Whereas some reports have indicated navigation setups provide equal or better results than conventional approaches, most trials have been performed in relatively small patient groups and clear follow-up data are missing. The reported computer-assisted surgery research concepts provide a glimpse in to the future application of navigation technologies in the field of urology.

  7. Patient-specific reconstruction plates are the missing link in computer-assisted mandibular reconstruction: A showcase for technical description.

    PubMed

    Cornelius, Carl-Peter; Smolka, Wenko; Giessler, Goetz A; Wilde, Frank; Probst, Florian A

    2015-06-01

    Preoperative planning of mandibular reconstruction has moved from mechanical simulation by dental model casts or stereolithographic models into an almost completely virtual environment. CAD/CAM applications allow a high level of accuracy by providing a custom template-assisted contouring approach for bone flaps. However, the clinical accuracy of CAD reconstruction is limited by the use of prebent reconstruction plates, an analogue step in an otherwise digital workstream. In this paper the integration of computerized, numerically-controlled (CNC) milled, patient-specific mandibular plates (PSMP) within the virtual workflow of computer-assisted mandibular free fibula flap reconstruction is illustrated in a clinical case. Intraoperatively, the bone segments as well as the plate arms showed a very good fit. Postoperative CT imaging demonstrated close approximation of the PSMP and fibular segments, and good alignment of native mandible and fibular segments and intersegmentally. Over a follow-up period of 12 months, there was an uneventful course of healing with good bony consolidation. The virtual design and automated fabrication of patient-specific mandibular reconstruction plates provide the missing link in the virtual workflow of computer-assisted mandibular free fibula flap reconstruction. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  9. Cartographic Modeling: Computer-assisted Analysis of Spatially Defined Neighborhoods

    NASA Technical Reports Server (NTRS)

    Berry, J. K.; Tomlin, C. D.

    1982-01-01

    Cartographic models addressing a wide variety of applications are composed of fundamental map processing operations. These primitive operations are neither data base nor application-specific. By organizing the set of operations into a mathematical-like structure, the basis for a generalized cartographic modeling framework can be developed. Among the major classes of primitive operations are those associated with reclassifying map categories, overlaying maps, determining distance and connectivity, and characterizing cartographic neighborhoods. The conceptual framework of cartographic modeling is established and techniques for characterizing neighborhoods are used as a means of demonstrating some of the more sophisticated procedures of computer-assisted map analysis. A cartographic model for assessing effective roundwood supply is briefly described as an example of a computer analysis. Most of the techniques described have been implemented as part of the map analysis package developed at the Yale School of Forestry and Environmental Studies.

  10. MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    PubMed

    Andriole, K

    2012-06-01

    Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality of care provided to patients using an evidence-based approach, to assure safety in the clinical and research environments, to facilitate efficiency in the workplace, and to accelerate knowledge discovery. Use-cases describing several areas of informatics activity will be given to illustrate current limitations that would benefit from medical physicist participation, and conversely areas in which informaticists may contribute to the solution. Topics to be discussed include radiation dose monitoring, process management and quality control, display technologies, business analytics techniques, and quantitative imaging. Quantitative imaging is increasingly becoming an essential part of biomedicalresearch as well as being incorporated into clinical diagnostic activities. Referring clinicians are asking for more objective information to be gleaned from the imaging tests that they order so that they may make the best clinical management decisions for their patients. Medical Physicists may be called upon to identify existing issues as well as develop, validate and implement new approaches and technologies to help move the field further toward quantitative imaging methods for the future. Biomedical imaging informatics tools and techniques such as standards, integration, data mining, cloud computing and new systems architectures, ontologies and lexicons, data visualization and navigation tools, and business analytics applications can be used to overcome some of the existing limitations. 1. Describe what is meant by Medical Imaging Informatics and understand why the medical physicist should care. 2. Identify existing limitations in information technologies with respect to Medical Physics, and conversely see how Informatics may assist the medical physicist in filling some of the current gaps in their activities. 3. Understand general informatics concepts and areas of investigation including imaging and workflow standards, systems integration, computing architectures, ontologies, data mining and business analytics, data visualization and human-computer interface tools, and the importance of quantitative imaging for the future of Medical Physics and Imaging Informatics. 4. Become familiar with on-going efforts to address current challenges facing future research into and clinical implementation of quantitative imaging applications. © 2012 American Association of Physicists in Medicine.

  11. Correlating MALDI and MRI Biomarkers of Breast Cancer

    DTIC Science & Technology

    2010-07-01

    resonance imaging ( MRI ) with matrix-assisted laser desorption ionization (MALDI) analysis of healthy and tumorous ex vivo specimens in order to examine the...assess the correlation between physiological parameters reported by magnetic resonance (MR) imaging and tumor protein distribution determined from... imaging research (e.g., Cancer Imaging , Quantitative Magnetic Resonance Imaging , and Medical Image Registration classes) • completion of

  12. BaffleText: a Human Interactive Proof

    NASA Astrophysics Data System (ADS)

    Chew, Monica; Baird, Henry S.

    2003-01-01

    Internet services designed for human use are being abused by programs. We present a defense against such attacks in the form of a CAPTCHA (Completely Automatic Public Turing test to tell Computers and Humans Apart) that exploits the difference in ability between humans and machines in reading images of text. CAPTCHAs are a special case of 'human interactive proofs,' a broad class of security protocols that allow people to identify themselves over networks as members of given groups. We point out vulnerabilities of reading-based CAPTCHAs to dictionary and computer-vision attacks. We also draw on the literature on the psychophysics of human reading, which suggests fresh defenses available to CAPTCHAs. Motivated by these considerations, we propose BaffleText, a CAPTCHA which uses non-English pronounceable words to defend against dictionary attacks, and Gestalt-motivated image-masking degradations to defend against image restoration attacks. Experiments on human subjects confirm the human legibility and user acceptance of BaffleText images. We have found an image-complexity measure that correlates well with user acceptance and assists in engineering the generation of challenges to fit the ability gap. Recent computer-vision attacks, run independently by Mori and Jitendra, suggest that BaffleText is stronger than two existing CAPTCHAs.

  13. Computer-based quantitative computed tomography image analysis in idiopathic pulmonary fibrosis: A mini review.

    PubMed

    Ohkubo, Hirotsugu; Nakagawa, Hiroaki; Niimi, Akio

    2018-01-01

    Idiopathic pulmonary fibrosis (IPF) is the most common type of progressive idiopathic interstitial pneumonia in adults. Many computer-based image analysis methods of chest computed tomography (CT) used in patients with IPF include the mean CT value of the whole lungs, density histogram analysis, density mask technique, and texture classification methods. Most of these methods offer good assessment of pulmonary functions, disease progression, and mortality. Each method has merits that can be used in clinical practice. One of the texture classification methods is reported to be superior to visual CT scoring by radiologist for correlation with pulmonary function and prediction of mortality. In this mini review, we summarize the current literature on computer-based CT image analysis of IPF and discuss its limitations and several future directions. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  14. Machine learning techniques for breast cancer computer aided diagnosis using different image modalities: A systematic review.

    PubMed

    Yassin, Nisreen I R; Omran, Shaimaa; El Houby, Enas M F; Allam, Hemat

    2018-03-01

    The high incidence of breast cancer in women has increased significantly in the recent years. Physician experience of diagnosing and detecting breast cancer can be assisted by using some computerized features extraction and classification algorithms. This paper presents the conduction and results of a systematic review (SR) that aims to investigate the state of the art regarding the computer aided diagnosis/detection (CAD) systems for breast cancer. The SR was conducted using a comprehensive selection of scientific databases as reference sources, allowing access to diverse publications in the field. The scientific databases used are Springer Link (SL), Science Direct (SD), IEEE Xplore Digital Library, and PubMed. Inclusion and exclusion criteria were defined and applied to each retrieved work to select those of interest. From 320 studies retrieved, 154 studies were included. However, the scope of this research is limited to scientific and academic works and excludes commercial interests. This survey provides a general analysis of the current status of CAD systems according to the used image modalities and the machine learning based classifiers. Potential research studies have been discussed to create a more objective and efficient CAD systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Stereoscopy in orthopaedics

    NASA Astrophysics Data System (ADS)

    Tan, S. L. E.

    2005-03-01

    Stereoscopy was used in medicine as long ago as 1898, but has not gained widespread acceptance except for a peak in the 1930's. It retains a use in orthopaedics in the form of Radiostereogrammetrical Analysis (RSA), though this is now done by computer software without using stereopsis. Combining computer assisted stereoscopic displays with both conventional plain films and reconstructed volumetric axial data, we are reassessing the use of stereoscopy in orthopaedics. Applications include use in developing nations or rural settings, erect patients where axial imaging cannot be used, and complex deformity and trauma reconstruction. Extension into orthopaedic endoscopic systems and teaching aids (e.g. operative videos) are further possibilities. The benefits of stereoscopic vision in increased perceived resolution and depth perception can help orthopaedic surgeons achieve more accurate diagnosis and better pre-operative planning. Limitations to currently available stereoscopic displays which need to be addressed prior to widespread acceptance are: availability of hardware and software, loss of resolution, use of glasses, and image "ghosting". Journal publication, the traditional mode of information dissemination in orthopaedics, is also viewed as a hindrance to the acceptance of stereoscopy - it does not deliver the full impact of stereoscopy and "hands-on" demonstrations are needed.

  16. Computer-aided diagnosis of prostate cancer in the peripheral zone using multiparametric MRI

    NASA Astrophysics Data System (ADS)

    Niaf, Emilie; Rouvière, Olivier; Mège-Lechevallier, Florence; Bratan, Flavie; Lartizien, Carole

    2012-06-01

    This study evaluated a computer-assisted diagnosis (CADx) system for determining a likelihood measure of prostate cancer presence in the peripheral zone (PZ) based on multiparametric magnetic resonance (MR) imaging, including T2-weighted, diffusion-weighted and dynamic contrast-enhanced MRI at 1.5 T. Based on a feature set derived from grey-level images, including first-order statistics, Haralick features, gradient features, semi-quantitative and quantitative (pharmacokinetic modelling) dynamic parameters, four kinds of classifiers were trained and compared : nonlinear support vector machine (SVM), linear discriminant analysis, k-nearest neighbours and naïve Bayes classifiers. A set of feature selection methods based on t-test, mutual information and minimum-redundancy-maximum-relevancy criteria were also compared. The aim was to discriminate between the relevant features as well as to create an efficient classifier using these features. The diagnostic performances of these different CADx schemes were evaluated based on a receiver operating characteristic (ROC) curve analysis. The evaluation database consisted of 30 sets of multiparametric MR images acquired from radical prostatectomy patients. Using histologic sections as the gold standard, both cancer and nonmalignant (but suspicious) tissues were annotated in consensus on all MR images by two radiologists, a histopathologist and a researcher. Benign tissue regions of interest (ROIs) were also delineated in the remaining prostate PZ. This resulted in a series of 42 cancer ROIs, 49 benign but suspicious ROIs and 124 nonsuspicious benign ROIs. From the outputs of all evaluated feature selection methods on the test bench, a restrictive set of about 15 highly informative features coming from all MR sequences was discriminated, thus confirming the validity of the multiparametric approach. Quantitative evaluation of the diagnostic performance yielded a maximal area under the ROC curve (AUC) of 0.89 (0.81-0.94) for the discrimination of the malignant versus nonmalignant tissues and 0.82 (0.73-0.90) for the discrimination of the malignant versus suspicious tissues when combining the t-test feature selection approach with a SVM classifier. A preliminary comparison showed that the optimal CADx scheme mimicked, in terms of AUC, the human experts in differentiating malignant from suspicious tissues, thus demonstrating its potential for assisting cancer identification in the PZ.

  17. USC orthogonal multiprocessor for image processing with neural networks

    NASA Astrophysics Data System (ADS)

    Hwang, Kai; Panda, Dhabaleswar K.; Haddadi, Navid

    1990-07-01

    This paper presents the architectural features and imaging applications of the Orthogonal MultiProcessor (OMP) system, which is under construction at the University of Southern California with research funding from NSF and assistance from several industrial partners. The prototype OMP is being built with 16 Intel i860 RISC microprocessors and 256 parallel memory modules using custom-designed spanning buses, which are 2-D interleaved and orthogonally accessed without conflicts. The 16-processor OMP prototype is targeted to achieve 430 MIPS and 600 Mflops, which have been verified by simulation experiments based on the design parameters used. The prototype OMP machine will be initially applied for image processing, computer vision, and neural network simulation applications. We summarize important vision and imaging algorithms that can be restructured with neural network models. These algorithms can efficiently run on the OMP hardware with linear speedup. The ultimate goal is to develop a high-performance Visual Computer (Viscom) for integrated low- and high-level image processing and vision tasks.

  18. Evaluation of a computational model to predict elbow range of motion

    PubMed Central

    Nishiwaki, Masao; Johnson, James A.; King, Graham J. W.; Athwal, George S.

    2014-01-01

    Computer models capable of predicting elbow flexion and extension range of motion (ROM) limits would be useful for assisting surgeons in improving the outcomes of surgical treatment of patients with elbow contractures. A simple and robust computer-based model was developed that predicts elbow joint ROM using bone geometries calculated from computed tomography image data. The model assumes a hinge-like flexion-extension axis, and that elbow passive ROM limits can be based on terminal bony impingement. The model was validated against experimental results with a cadaveric specimen, and was able to predict the flexion and extension limits of the intact joint to 0° and 3°, respectively. The model was also able to predict the flexion and extension limits to 1° and 2°, respectively, when simulated osteophytes were inserted into the joint. Future studies based on this approach will be used for the prediction of elbow flexion-extension ROM in patients with primary osteoarthritis to help identify motion-limiting hypertrophic osteophytes, and will eventually permit real-time computer-assisted navigated excisions. PMID:24841799

  19. Meta-Analysis of Stress Myocardial Perfusion Imaging

    ClinicalTrials.gov

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  20. Rhinoplasty perioperative database using a personal digital assistant.

    PubMed

    Kotler, Howard S

    2004-01-01

    To construct a reliable, accurate, and easy-to-use handheld computer database that facilitates the point-of-care acquisition of perioperative text and image data specific to rhinoplasty. A user-modified database (Pendragon Forms [v.3.2]; Pendragon Software Corporation, Libertyville, Ill) and graphic image program (Tealpaint [v.4.87]; Tealpaint Software, San Rafael, Calif) were used to capture text and image data, respectively, on a Palm OS (v.4.11) handheld operating with 8 megabytes of memory. The handheld and desktop databases were maintained secure using PDASecure (v.2.0) and GoldSecure (v.3.0) (Trust Digital LLC, Fairfax, Va). The handheld data were then uploaded to a desktop database of either FileMaker Pro 5.0 (v.1) (FileMaker Inc, Santa Clara, Calif) or Microsoft Access 2000 (Microsoft Corp, Redmond, Wash). Patient data were collected from 15 patients undergoing rhinoplasty in a private practice outpatient ambulatory setting. Data integrity was assessed after 6 months' disk and hard drive storage. The handheld database was able to facilitate data collection and accurately record, transfer, and reliably maintain perioperative rhinoplasty data. Query capability allowed rapid search using a multitude of keyword search terms specific to the operative maneuvers performed in rhinoplasty. Handheld computer technology provides a method of reliably recording and storing perioperative rhinoplasty information. The handheld computer facilitates the reliable and accurate storage and query of perioperative data, assisting the retrospective review of one's own results and enhancement of surgical skills.

Top