Richardson, D
1997-12-01
This study compared student perceptions and learning outcomes of computer-assisted instruction against those of traditional didactic lectures. Components of Quantitative Circulatory Physiology (Biological Simulators) and Mechanical Properties of Active Muscle (Trinity Software) were used to teach regulation of tissue blood flow and muscle mechanics, respectively, in the course Medical Physiology. These topics were each taught, in part, by 1) standard didactic lectures, 2) computer-assisted lectures, and 3) computer laboratory assignment. Subjective evaluation was derived from a questionnaire assessing student opinions of the effectiveness of each method. Objective evaluation consisted of comparing scores on examination questions generated from each method. On a 1-10 scale, effectiveness ratings were higher (P < 0.0001) for the didactic lectures (7.7) compared with either computer-assisted lecture (3.8) or computer laboratory (4.2) methods. A follow-up discussion with representatives from the class indicated that students did not perceive computer instruction as being time effective. However, examination scores from computer laboratory questions (94.3%) were significantly higher compared with ones from either computer-assisted (89.9%; P < 0.025) or didactic (86.6%; P < 0.001) lectures. Thus computer laboratory instruction enhanced learning outcomes in medical physiology despite student perceptions to the contrary.
NASA Astrophysics Data System (ADS)
Heglund, Brian
Educators recognize the importance of reasoning ability for development of critical thinking skills, conceptual change, metacognition, and participation in 21st century society. There is a recognized need for students to improve their skills of argumentation, however, argumentation is not explicitly taught outside logic and philosophy---subjects that are not part of the K-12 curriculum. One potential way of supporting the development of argumentation skills in the K-12 context is through incorporating Computer-Assisted Argument Mapping to evaluate arguments. This quasi-experimental study tested the effects of such argument mapping software and was informed by the following two research questions: 1. To what extent does the collaborative use of Computer-Assisted Argumentation Mapping to evaluate competing theories influence the critical thinking skill of argument evaluation, metacognitive awareness, and conceptual knowledge acquisition in high school Advanced Placement physics, compared to the more traditional method of text tables that does not employ Computer-Assisted Argumentation Mapping? 2. What are the student perceptions of the pros and cons of argument evaluation in the high school Advanced Placement physics environment? This study examined changes in critical thinking skills, including argumentation evaluation skills, as well as metacognitive awareness and conceptual knowledge, in two groups: a treatment group using Computer-Assisted Argumentation Mapping to evaluate physics arguments, and a comparison group using text tables to evaluate physics arguments. Quantitative and qualitative methods for collecting and analyzing data were used to answer the research questions. Quantitative data indicated no significant difference between the experimental groups, and qualitative data suggested students perceived pros and cons of argument evaluation in the high school Advanced Placement physics environment, such as self-reported sense of improvement in argument evaluation and low perceived value of the learning task, respectively. The discussion presents implications for practice and research, such as introducing motivation scaffolds to support appreciation of task value, and addressing major differences between the design of this study and similar published studies, respectively. This work provides contributions in that it tested the effect of Computer-Assisted Argumentation Mapping on the critical thinking skills of twelfth-grade students within the context of evaluating physics arguments, a previously unexplored age group and domain.
Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.
Kemp, Pavlina S; VanderVeen, Deborah K
2016-01-01
The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding the presence of plus disease, an important criterion in deciding the necessity of treatment of vision-threatening retinopathy of prematurity. A review of literature found that several techniques have been published examining the process and role of computer aided analysis of plus disease in retinopathy of prematurity. These techniques use semiautomated image analysis techniques to evaluate retinal vascular dilation and tortuosity, using calculated parameters to evaluate presence or absence of plus disease. These values are then compared with expert consensus. The study concludes that computer-aided image analysis has the potential to use quantitative and objective criteria to act as a supplemental tool in evaluating for plus disease in the setting of retinopathy of prematurity.
Programming Language CAMIL II: Implementation and Evaluation.
ERIC Educational Resources Information Center
Gardner, Edward
A reimplementation of Computer assisted/managed instruction language (CAMIL) for qualitative and quantitative improvements in the software is presented. The reformatted language is described narratively, and major components of the system software are indicated and discussed. Authoring aids and imbedded support facilities are also described, and…
NASA Technical Reports Server (NTRS)
Parada, N. D. J. (Principal Investigator); Paradella, W. R.; Vitorello, I.
1982-01-01
Several aspects of computer-assisted analysis techniques for image enhancement and thematic classification by which LANDSAT MSS imagery may be treated quantitatively are explained. On geological applications, computer processing of digital data allows, possibly, the fullest use of LANDSAT data, by displaying enhanced and corrected data for visual analysis and by evaluating and assigning each spectral pixel information to a given class.
ERIC Educational Resources Information Center
Presperin, Jessica J., Ed.
This proceedings document contains approximately 250 papers and posters presented at a conference on the advancement of rehabilitation and assistive technology. Individual sessions focused on the following topics: quantitative functional evaluation, upper limb and therapeutic stimulation, human-computer interface developments, information…
NASA Astrophysics Data System (ADS)
Kuan, Wen-Hsuan; Tseng, Chi-Hung; Chen, Sufen; Wong, Ching-Chang
2016-06-01
We propose an integrated curriculum to establish essential abilities of computer programming for the freshmen of a physics department. The implementation of the graphical-based interfaces from Scratch to LabVIEW then to LabVIEW for Arduino in the curriculum `Computer-Assisted Instrumentation in the Design of Physics Laboratories' brings rigorous algorithm and syntax protocols together with imagination, communication, scientific applications and experimental innovation. The effectiveness of the curriculum was evaluated via statistical analysis of questionnaires, interview responses, the increase in student numbers majoring in physics, and performance in a competition. The results provide quantitative support that the curriculum remove huge barriers to programming which occur in text-based environments, helped students gain knowledge of programming and instrumentation, and increased the students' confidence and motivation to learn physics and computer languages.
NASA Astrophysics Data System (ADS)
Heinert, G.; Mondorf, W.
1982-11-01
High speed image processing was used to analyse morphologic and metabolic characteristics of clinically relevant kidney tissue alterations.Qualitative computer-assisted histophotometry was performed to measure alterations in levels of the enzymes alkaline phosphatase (Ap),alanine aminopeptidase (AAP),g-glutamyltranspepti-dase (GGTP) and A-glucuronidase (B-G1) and AAP and GGTP immunologically determined in prepared renal and cancer tissue sections. A "Mioro-Videomat 2" image analysis system with a "Tessovar" macroscope,a computer-assisted "Axiomat" photomicroscope and an "Interactive Image Analysis System (IBAS)" were employed for analysing changes in enzyme activities determined by changes in absorbance or transmission.Diseased kidney as well as renal neoplastic tissues could be distinguished by significantly (wilcoxon test,p<0,05) decreased enzyme concentrations as compared to those found in normal human kidney tissues.This image analysis techniques might be of potential use in diagnostic and prognostic evaluation of renal cancer and diseased kidney tissues.
Man-machine analysis of translation and work tasks of Skylab films
NASA Technical Reports Server (NTRS)
Hosler, W. W.; Boelter, J. G.; Morrow, J. R., Jr.; Jackson, J. T.
1979-01-01
An objective approach to determine the concurrent validity of computer-graphic models is real time film analysis. This technique was illustrated through the procedures and results obtained in an evaluation of translation of Skylab mission astronauts. The quantitative analysis was facilitated by the use of an electronic film analyzer, minicomputer, and specifically supportive software. The uses of this technique for human factors research are: (1) validation of theoretical operator models; (2) biokinetic analysis; (3) objective data evaluation; (4) dynamic anthropometry; (5) empirical time-line analysis; and (6) consideration of human variability. Computer assisted techniques for interface design and evaluation have the potential for improving the capability for human factors engineering.
Engineering Students' Use of Computer Assisted Learning (CAL)
ERIC Educational Resources Information Center
Huczynski, Andrzej; Johnston, Scott Paul
2005-01-01
This study examines the use of Computer Assisted Learning (CAL) by undergraduate engineering students studying a business and management course. Discussing both the relationship between management and engineering and CAL applied to engineering education, this study is based on a survey of 82 undergraduates and adopts a quantitative research…
Computer-Assisted Reporting in Classrooms: A Decade of Diffusion and a Comparison to Newsrooms.
ERIC Educational Resources Information Center
Davenport, Lucinda D.; Fico, Fred; DeFleur, Margaret H.
2002-01-01
Replicates and updates the only other research that examined the adoption of computer-assisted reporting instruction in journalism schools quantitatively. Compares the different computerized sources being used in newsrooms and classrooms, and elicits the reasons that these sources are being used in each environment. Concludes many programs are…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strauss, B.M.; Putatunda, S.K.
1990-01-01
Papers are presented on the application of quantitative fractography and computed tomography to fracture processes in materials, the relationships between fractographic features and material toughness, the quantitative analysis of fracture surfaces using fractals, and the analysis and interpretation of aircraft component defects by means of quantitative fractography. Also discussed are the characteristics of hydrogen-assisted cracking measured by the holding-load and fractographic method, a fractographic study of isolated cleavage regions in nuclear pressure vessel steels and their weld metals, a fractographic and metallographic study of the initiation of brittle fracture in weldments, cracking mechanisms for mean stress/strain low-cycle multiaxial fatigue loadings,more » and corrosion fatigue crack arrest in Al alloys.« less
ERIC Educational Resources Information Center
Tafazoli, Dara; Gómez Parra, Mª Elena; Huertas Abril, Cristina A.
2018-01-01
The purpose of this study was to compare the attitude of Iranian and non-Iranian English language students' attitudes towards Computer-Assisted Language Learning (CALL). Furthermore, the relations of gender, education level, and age to their attitude are investigated. A convergent mixed methods design was used for analyzing both quantitative and…
ERIC Educational Resources Information Center
Hussmann, Katja; Grande, Marion; Meffert, Elisabeth; Christoph, Swetlana; Piefke, Martina; Willmes, Klaus; Huber, Walter
2012-01-01
Although generally accepted as an important part of aphasia assessment, detailed analysis of spontaneous speech is rarely carried out in clinical practice mostly due to time limitations. The Aachener Sprachanalyse (ASPA; Aachen Speech Analysis) is a computer-assisted method for the quantitative analysis of German spontaneous speech that allows for…
ERIC Educational Resources Information Center
Ekstrom, James
2001-01-01
Advocates using computer imaging technology to assist students in doing projects in which determining density is important. Students can study quantitative comparisons of masses, lengths, and widths using computer software. Includes figures displaying computer images of shells, yeast cultures, and the Aral Sea. (SAH)
Design of a miniature implantable left ventricular assist device using CAD/CAM technology.
Okamoto, Eiji; Hashimoto, Takuya; Mitamura, Yoshinori
2003-01-01
In this study, we developed a new miniature motor-driven pulsatile left ventricular assist device (LVAD) for implantation into a Japanese patient of average build by means of computer-aided design and manufacturing (CAD/CAM) technology. A specially designed miniature ball-screw and a high-performance brushless DC motor were used in an artificial heart actuator to allow miniaturization. A blood pump chamber (stroke volume 55 ml) and an inflow and outflow port were designed by computational fluid dynamics (CFD) analysis. The geometry of the blood pump was evaluated using the value of index of pump geometry (IPG) = (Reynolds shear stress) x (occupied volume) as a quantitative index for optimization. The calculated value of IPG varied from 20.6 Nm to 49.1 Nm, depending on small variations in pump geometry. We determined the optimum pump geometry based on the results of quantitative evaluation using IPG and qualitative evaluation using the flow velocity distribution with blood flow tracking. The geometry of the blood pump that gave lower shear stress had more optimum spiral flow around the diaphragm-housing (D-H) junction. The volume and weight of the new LVAD, made of epoxy resin, is 309 ml and 378 g, but further miniaturization will be possible by improving the geometry of both the blood pump and the back casing. Our results show that our new design method for an implantable LVAD using CAD/CAM promises to improve blood compatibility with greater miniaturization.
ERIC Educational Resources Information Center
Nee, John G.; Kare, Audhut P.
1987-01-01
Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)
Anconina, Reut; Zur, Dinah; Kesler, Anat; Lublinsky, Svetlana; Toledano, Ronen; Novack, Victor; Benkobich, Elya; Novoa, Rosa; Novic, Evelyne Farkash; Shelef, Ilan
2017-06-01
Dural sinuses vary in size and shape in many pathological conditions with abnormal intracranial pressure. Size and shape normograms of dural brain sinuses are not available. The creation of such normograms may enable computer-assisted comparison to pathologic exams and facilitate diagnoses. The purpose of this study was to quantitatively evaluate normal magnetic resonance venography (MRV) studies in order to create normograms of dural sinuses using a computerized algorithm for vessel cross-sectional analysis. This was a retrospective analysis of MRV studies of 30 healthy persons. Data were analyzed using a specially developed Matlab algorithm for vessel cross-sectional analysis. The cross-sectional area and shape measurements were evaluated to create normograms. Mean cross-sectional size was 53.27±13.31 for the right transverse sinus (TS), 46.87+12.57 for the left TS (p=0.089) and 36.65+12.38 for the superior sagittal sinus. Normograms were created. The distribution of cross-sectional areas along the vessels showed distinct patterns and a parallel course for the median, 25th, 50th and 75th percentiles. In conclusion, using a novel computerized method for vessel cross-sectional analysis we were able to quantitatively characterize dural sinuses of healthy persons and create normograms. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Frazier, John M.; Mattie, D. R.; Hussain, Saber; Pachter, Ruth; Boatz, Jerry; Hawkins, T. W.
2000-01-01
The development of quantitative structure-activity relationship (QSAR) is essential for reducing the chemical hazards of new weapon systems. The current collaboration between HEST (toxicology research and testing), MLPJ (computational chemistry) and PRS (computational chemistry, new propellant synthesis) is focusing R&D efforts on basic research goals that will rapidly transition to useful products for propellant development. Computational methods are being investigated that will assist in forecasting cellular toxicological end-points. Models developed from these chemical structure-toxicity relationships are useful for the prediction of the toxicological endpoints of new related compounds. Research is focusing on the evaluation tools to be used for the discovery of such relationships and the development of models of the mechanisms of action. Combinations of computational chemistry techniques, in vitro toxicity methods, and statistical correlations, will be employed to develop and explore potential predictive relationships; results for series of molecular systems that demonstrate the viability of this approach are reported. A number of hydrazine salts have been synthesized for evaluation. Computational chemistry methods are being used to elucidate the mechanism of action of these salts. Toxicity endpoints such as viability (LDH) and changes in enzyme activity (glutahoione peroxidase and catalase) are being experimentally measured as indicators of cellular damage. Extrapolation from computational/in vitro studies to human toxicity, is the ultimate goal. The product of this program will be a predictive tool to assist in the development of new, less toxic propellants.
Quantitative Muscle Ultrasonography in Carpal Tunnel Syndrome.
Lee, Hyewon; Jee, Sungju; Park, Soo Ho; Ahn, Seung-Chan; Im, Juneho; Sohn, Min Kyun
2016-12-01
To assess the reliability of quantitative muscle ultrasonography (US) in healthy subjects and to evaluate the correlation between quantitative muscle US findings and electrodiagnostic study results in patients with carpal tunnel syndrome (CTS). The clinical significance of quantitative muscle US in CTS was also assessed. Twenty patients with CTS and 20 age-matched healthy volunteers were recruited. All control and CTS subjects underwent a bilateral median and ulnar nerve conduction study (NCS) and quantitative muscle US. Transverse US images of the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) were obtained to measure muscle cross-sectional area (CSA), thickness, and echo intensity (EI). EI was determined using computer-assisted, grayscale analysis. Inter-rater and intra-rater reliability for quantitative muscle US in control subjects, and differences in muscle thickness, CSA, and EI between the CTS patient and control groups were analyzed. Relationships between quantitative US parameters and electrodiagnostic study results were evaluated. Quantitative muscle US had high inter-rater and intra-rater reliability in the control group. Muscle thickness and CSA were significantly decreased, and EI was significantly increased in the APB of the CTS group (all p<0.05). EI demonstrated a significant positive correlation with latency of the median motor and sensory NCS in CTS patients (p<0.05). These findings suggest that quantitative muscle US parameters may be useful for detecting muscle changes in CTS. Further study involving patients with other neuromuscular diseases is needed to evaluate peripheral muscle change using quantitative muscle US.
Laboratory data base for isomer-specific determination of polychlorinated biphenyls
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, T.R.; Campbell, R.D.; Stalling, D.L.
1984-07-01
A computer-assisted technique for quantitative determination of polychlorinated biphenyl isomers is described. PCB isomers were identified by use of a retention index system with n-alkyl trichloroacetates as retention index marker compounds. A laboratory data base system was developed to aid in editing and quantitation of data generated from capillary gas chromatographic data. Data base management was provided by computer programs written in DSM-11 (Digital Standard MUMPS) for the PDP-11 family of computers. 13 references, 4 figures, 2 tables.
Blanson Henkemans, O. A.; Rogers, W. A.; Fisk, A. D.; Neerincx, M. A.; Lindenberg, J.; van der Mast, C. A. P. G.
2014-01-01
Summary Objectives We developed an adaptive computer assistant for the supervision of diabetics’ self-care, to support limiting illness and need for acute treatment, and improve health literacy. This assistant monitors self-care activities logged in the patient’s electronic diary. Accordingly, it provides context-aware feedback. The objective was to evaluate whether older adults in general can make use of the computer assistant and to compare an adaptive computer assistant with a fixed one, concerning its usability and contribution to health literacy. Methods We conducted a laboratory experiment in the Georgia Tech Aware Home wherein 28 older adults participated in a usability evaluation of the computer assistant, while engaged in scenarios reflecting normal and health-critical situations. We evaluated the assistant on effectiveness, efficiency, satisfaction, and educational value. Finally, we studied the moderating effects of the subjects’ personal characteristics. Results Logging self-care tasks and receiving feedback from the computer assistant enhanced the subjects’ knowledge of diabetes. The adaptive assistant was more effective in dealing with normal and health-critical situations, and, generally, it led to more time efficiency. Subjects’ personal characteristics had substantial effects on the effectiveness and efficiency of the two computer assistants. Conclusions Older adults were able to use the adaptive computer assistant. In addition, it had a positive effect on the development of health literacy. The assistant has the potential to support older diabetics’ self care while maintaining quality of life. PMID:18213433
Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon
2014-01-01
One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.
Digital interactive learning of oral radiographic anatomy.
Vuchkova, J; Maybury, T; Farah, C S
2012-02-01
Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.
Computer-Assisted Reading Intervention in a Secondary School: An Evaluation Study.
ERIC Educational Resources Information Center
Lynch, Lisa; Fawcett, Angela J.; Nicolson, Roderick I.
2000-01-01
RITA (Reader's Interactive Teaching Assistant) is a computer-based literacy support system that assists, rather than replaces, the teacher in providing support tailored to each child's profile of reading attainments. This study evaluated the effectiveness of RITA in secondary school with 8 children having very seriously disadvantaged literacy…
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-01-01
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-12-15
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less
Tacchino, Giulia; Gandolla, Marta; Coelli, Stefania; Barbieri, Riccardo; Pedrocchi, Alessandra; Bianchi, Anna M
2017-06-01
Two key ingredients of a successful neuro-rehabilitative intervention have been identified as intensive and repetitive training and subject's active participation, which can be coupled in an active robot-assisted training. To exploit these two elements, we recorded electroencephalography, electromyography and kinematics signals from nine healthy subjects performing a 2×2 factorial design protocol, with subject's volitional intention and robotic glove assistance as factors. We quantitatively evaluated primary sensorimotor, premotor and supplementary motor areas activation during movement execution by computing event-related desynchronization (ERD) patterns associated to mu and beta rhythms. ERD patterns showed a similar behavior for all investigated regions: statistically significant ERDs began earlier in conditions requiring subject's volitional contribution; ERDs were prolonged towards the end of movement in conditions in which the robotic assistance was present. Our study suggests that the combination between subject volitional contribution and movement assistance provided by the robotic device (i.e., active robot-assisted modality) is able to provide early brain activation (i.e., earlier ERD) associated with stronger proprioceptive feedback (i.e., longer ERD). This finding might be particularly important for neurological patients, where movement cannot be completed autonomously and passive/active robot-assisted modalities are the only possibilities of execution.
Assessing the activity of sarcoidosis: quantitative /sup 67/Ga-citrate imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fajman, W.A.; Greenwald, L.V.; Staton, G.
1984-04-01
Three different methods of quantitating /sup 67/Ga-citrate lung images - a visual index, a computer-assisted index, and the total-lung-to-background ratio - were compared in 71 studies of patients with biopsy-proven sarcoidosis. Fifty consecutive cases were analyzed independently by two different observers using all three methods. In these studies, each index was correlated with the cell differential in the bronchoalveolar lavage fluid. The total-lung-to-background ratio proved to be the simplest to perform; correlated best with the original visual index and the percentage of lymphocytes obtained in bronchoalveolar lavage fluid. Sensitivity for detecting active disease was 84% compared with 64% and 58%more » for the visual and computer-assisted indices, respectively, with no sacrifice in specificity.« less
Quantitative Evaluation of Performance during Robot-assisted Treatment.
Peri, E; Biffi, E; Maghini, C; Servodio Iammarrone, F; Gagliardi, C; Germiniasi, C; Pedrocchi, A; Turconi, A C; Reni, G
2016-01-01
This article is part of the Focus Theme of Methods of Information in Medicine on "Methodologies, Models and Algorithms for Patients Rehabilitation". The great potential of robots in extracting quantitative and meaningful data is not always exploited in clinical practice. The aim of the present work is to describe a simple parameter to assess the performance of subjects during upper limb robotic training exploiting data automatically recorded by the robot, with no additional effort for patients and clinicians. Fourteen children affected by cerebral palsy (CP) performed a training with Armeo®Spring. Each session was evaluated with P, a simple parameter that depends on the overall performance recorded, and median and interquartile values were computed to perform a group analysis. Median (interquartile) values of P significantly increased from 0.27 (0.21) at T0 to 0.55 (0.27) at T1 . This improvement was functionally validated by a significant increase of the Melbourne Assessment of Unilateral Upper Limb Function. The parameter described here was able to show variations in performance over time and enabled a quantitative evaluation of motion abilities in a way that is reliable with respect to a well-known clinical scale.
Chi, Chia-Fen; Tseng, Li-Kai; Jang, Yuh
2012-07-01
Many disabled individuals lack extensive knowledge about assistive technology, which could help them use computers. In 1997, Denis Anson developed a decision tree of 49 evaluative questions designed to evaluate the functional capabilities of the disabled user and choose an appropriate combination of assistive devices, from a selection of 26, that enable the individual to use a computer. In general, occupational therapists guide the disabled users through this process. They often have to go over repetitive questions in order to find an appropriate device. A disabled user may require an alphanumeric entry device, a pointing device, an output device, a performance enhancement device, or some combination of these. Therefore, the current research eliminates redundant questions and divides Anson's decision tree into multiple independent subtrees to meet the actual demand of computer users with disabilities. The modified decision tree was tested by six disabled users to prove it can determine a complete set of assistive devices with a smaller number of evaluative questions. The means to insert new categories of computer-related assistive devices was included to ensure the decision tree can be expanded and updated. The current decision tree can help the disabled users and assistive technology practitioners to find appropriate computer-related assistive devices that meet with clients' individual needs in an efficient manner.
Modeling the Learner in Computer-Assisted Instruction
ERIC Educational Resources Information Center
Fletcher, J. D.
1975-01-01
This paper briefly reviews relevant work in four areas: 1) quantitative models of memory; 2) regression models of performance; 3) automation models of performance; and 4) artificial intelligence. (Author/HB)
Maity, Maitreya; Dhane, Dhiraj; Mungle, Tushar; Maiti, A K; Chakraborty, Chandan
2017-10-26
Web-enabled e-healthcare system or computer assisted disease diagnosis has a potential to improve the quality and service of conventional healthcare delivery approach. The article describes the design and development of a web-based distributed healthcare management system for medical information and quantitative evaluation of microscopic images using machine learning approach for malaria. In the proposed study, all the health-care centres are connected in a distributed computer network. Each peripheral centre manages its' own health-care service independently and communicates with the central server for remote assistance. The proposed methodology for automated evaluation of parasites includes pre-processing of blood smear microscopic images followed by erythrocytes segmentation. To differentiate between different parasites; a total of 138 quantitative features characterising colour, morphology, and texture are extracted from segmented erythrocytes. An integrated pattern classification framework is designed where four feature selection methods viz. Correlation-based Feature Selection (CFS), Chi-square, Information Gain, and RELIEF are employed with three different classifiers i.e. Naive Bayes', C4.5, and Instance-Based Learning (IB1) individually. Optimal features subset with the best classifier is selected for achieving maximum diagnostic precision. It is seen that the proposed method achieved with 99.2% sensitivity and 99.6% specificity by combining CFS and C4.5 in comparison with other methods. Moreover, the web-based tool is entirely designed using open standards like Java for a web application, ImageJ for image processing, and WEKA for data mining considering its feasibility in rural places with minimal health care facilities.
Kiluk, Brian D.; Sugarman, Dawn E.; Nich, Charla; Gibbons, Carly J.; Martino, Steve; Rounsaville, Bruce J.; Carroll, Kathleen M.
2013-01-01
Objective Computer-assisted therapies offer a novel, cost-effective strategy for providing evidence-based therapies to a broad range of individuals with psychiatric disorders. However, the extent to which the growing body of randomized trials evaluating computer-assisted therapies meets current standards of methodological rigor for evidence-based interventions is not clear. Method A methodological analysis of randomized clinical trials of computer-assisted therapies for adult psychiatric disorders, published between January 1990 and January 2010, was conducted. Seventy-five studies that examined computer-assisted therapies for a range of axis I disorders were evaluated using a 14-item methodological quality index. Results Results indicated marked heterogeneity in study quality. No study met all 14 basic quality standards, and three met 13 criteria. Consistent weaknesses were noted in evaluation of treatment exposure and adherence, rates of follow-up assessment, and conformity to intention-to-treat principles. Studies utilizing weaker comparison conditions (e.g., wait-list controls) had poorer methodological quality scores and were more likely to report effects favoring the computer-assisted condition. Conclusions While several well-conducted studies have indicated promising results for computer-assisted therapies, this emerging field has not yet achieved a level of methodological quality equivalent to those required for other evidence-based behavioral therapies or pharmacotherapies. Adoption of more consistent standards for methodological quality in this field, with greater attention to potential adverse events, is needed before computer-assisted therapies are widely disseminated or marketed as evidence based. PMID:21536689
An Evaluation of the Effectiveness of a Computer-Assisted Reading Intervention
ERIC Educational Resources Information Center
Messer, David; Nash, Gilly
2018-01-01
Background: A cost-effective method to address reading delays is to use computer-assisted learning, but these techniques are not always effective. Methods: We evaluated a commercially available computer system that uses visual mnemonics, in a randomised controlled trial with 78 English-speaking children (mean age 7 years) who their schools…
Harling, Guy; Gumede, Dumile; Mutevedzi, Tinofa; McGrath, Nuala; Seeley, Janet; Pillay, Deenan; Bärnighausen, Till W; Herbst, Abraham J
2017-08-17
Self-interviews, where the respondent rather than the interviewer enters answers to questions, have been proposed as a way to reduce social desirability bias associated with interviewer-led interviews. Computer-assisted self-interviews (CASI) are commonly proposed since the computer programme can guide respondents; however they require both language and computer literacy. We evaluated the feasibility and acceptability of using electronic methods to administer quantitative sexual behaviour questionnaires in the Somkhele demographic surveillance area (DSA) in rural KwaZulu-Natal, South Africa. We conducted a four-arm randomized trial of paper-and-pen-interview, computer-assisted personal-interview (CAPI), CASI and audio-CASI with an age-sex-urbanicity stratified sample of 504 adults resident in the DSA in 2015. We compared respondents' answers to their responses to the same questions in previous surveillance rounds. We also conducted 48 cognitive interviews, dual-coding responses using the Framework approach. Three hundred forty (67%) individuals were interviewed and covariates and participation rates were balanced across arms. CASI and audio-CASI were significantly slower than interviewer-led interviews. Item non-response rates were higher in self-interview arms. In single-paper meta-analysis, self-interviewed individuals reported more socially undesirable sexual behaviours. Cognitive interviews found high acceptance of both self-interviews and the use of electronic methods, with some concerns that self-interview methods required more participant effort and literacy. Electronic data collection methods, including self-interview methods, proved feasible and acceptable for completing quantitative sexual behaviour questionnaires in a poor, rural South African setting. However, each method had both benefits and costs, and the choice of method should be based on context-specific criteria.
Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R
2012-01-01
Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (p<0.01), compared to 45% of tasks completed by the senior resident group. High-impact educational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.
An Evaluation of Computer-Assisted Instruction for English Grammar Review.
ERIC Educational Resources Information Center
Oates, William
1981-01-01
The use of computer assisted instruction (CAI) at Indiana University to provide basic grammar review to beginning writing students, and the results of an evaluation of the PLATO system as a learning resource are described. At the time of the evaluation, the CAI curriculum in use was the Language Arts Routing System (LARS). The evaluation involved…
ERIC Educational Resources Information Center
Chesler, David J.
An improved general methodological approach for the development of computer-assisted evaluation of trainee performance in the computer-based simulation environment is formulated in this report. The report focuses on the Tactical Advanced Combat Direction and Electronic Warfare system (TACDEW) at the Fleet Anti-Air Warfare Training Center at San…
Frost, Mary E; Derby, Dustin C; Haan, Andrea G
2013-01-01
Objective : Changes in small business and insurance present challenges for newly graduated chiropractors. Technology that reaches identified, diverse learning styles may assist the chiropractic student in business classes to meet course outcomes better. Thus, the purpose of our study is to determine if the use of technology-based instructional aids enhance students' mastery of course learning outcomes. Methods : Using convenience sampling, 86 students completed a survey assessing course learning outcomes, learning style, and the helpfulness of lecture and computer-assisted learning related to content mastery. Quantitative analyses occurred. Results : Although respondents reported not finding the computer-assisted learning as helpful as the lecture, significant relationships were found between pre- and post-assisted learning measures of the learning outcomes 1 and 2 for the visual and kinesthetic groups. Surprisingly, however, all learning style groups exhibited significant pre- and post-assisted learning appraisal relationships with learning outcomes 3 and 4. Conclusion : While evidence exists within the current study of a relationship between students' learning of the course content corollary to the use of technologic instructional aids, the exact nature of the relationship remains unclear.
Frost, Mary E; Derby, Dustin C; Haan, Andrea G
2013-06-27
Objective : Changes in small business and insurance present challenges for newly graduated chiropractors. Technology that reaches identified, diverse learning styles may assist the chiropractic student in business classes to meet course outcomes better. Thus, the purpose of our study is to determine if the use of technology-based instructional aids enhance students' mastery of course learning outcomes. Methods : Using convenience sampling, 86 students completed a survey assessing course learning outcomes, learning style, and the helpfulness of lecture and computer-assisted learning related to content mastery. Quantitative analyses occurred. Results : Although respondents reported not finding the computer-assisted learning as helpful as the lecture, significant relationships were found between pre- and post-assisted learning measures of the learning outcomes 1 and 2 for the visual and kinesthetic groups. Surprisingly, however, all learning style groups exhibited significant pre- and post-assisted learning appraisal relationships with learning outcomes 3 and 4. Conclusion : While evidence exists within the current study of a relationship between students' learning of the course content corollary to the use of technologic instructional aids, the exact nature of the relationship remains unclear.
ERIC Educational Resources Information Center
Chen, Chiu-Jung; Liu, Pei-Lin
2007-01-01
This study evaluated the effects of a personalized computer-assisted mathematics problem-solving program on the performance and attitude of Taiwanese fourth grade students. The purpose of this study was to determine whether the personalized computer-assisted program improved student performance and attitude over the nonpersonalized program.…
ERIC Educational Resources Information Center
Kausar, Tayyaba; Choudhry, Bushra Naoreen; Gujjar, Aijaz Ahmed
2008-01-01
This study was aimed to evaluate the effectiveness of CAI vs. classroom lecture for computer science at ICS level. The objectives were to compare the learning effects of two groups with class room lecture and computer assisted instruction studying the same curriculum and the effects of CAI and CRL in terms of cognitive development. Hypothesis of…
ERIC Educational Resources Information Center
Kausar, Tayyaba; Choudhry, Bushra Naoreen; Gujjar, Aijaz Ahmed
2008-01-01
This study was aimed to evaluate the effectiveness of CAI vs. classroom lecture for computer science at ICS level. The objectives were to compare the learning effects of two groups with class room lecture and computer assisted instruction studying the same curriculum and the effects of CAI and CRL in terms of cognitive development. Hypothesis of…
ERIC Educational Resources Information Center
Ellsworth, Nancy J.
1990-01-01
This article reviews current resources on computer-assisted instruction. Included are sources of software and hardware evaluations, advances in current technology, research, an information hotline, and inventories of available technological assistance. (DB)
Engelberg, Jesse A.; Giberson, Richard T.; Young, Lawrence J.T.; Hubbard, Neil E.
2014-01-01
Microwave methods of fixation can dramatically shorten fixation times while preserving tissue structure; however, it remains unclear if adequate tissue antigenicity is preserved. To assess and validate antigenicity, robust quantitative methods and animal disease models are needed. We used two mouse mammary models of human breast cancer to evaluate microwave-assisted and standard 24-hr formalin fixation. The mouse models expressed four antigens prognostic for breast cancer outcome: estrogen receptor, progesterone receptor, Ki67, and human epidermal growth factor receptor 2. Using pathologist evaluation and novel methods of quantitative image analysis, we measured and compared the quality of antigen preservation, percentage of positive cells, and line plots of cell intensity. Visual evaluations by pathologists established that the amounts and patterns of staining were similar in tissues fixed by the different methods. The results of the quantitative image analysis provided a fine-grained evaluation, demonstrating that tissue antigenicity is preserved in tissues fixed using microwave methods. Evaluation of the results demonstrated that a 1-hr, 150-W fixation is better than a 45-min, 150-W fixation followed by a 15-min, 650-W fixation. The results demonstrated that microwave-assisted formalin fixation can standardize fixation times to 1 hr and produce immunohistochemistry that is in every way commensurate with longer conventional fixation methods. PMID:24682322
Computer-aided diagnosis of prostate cancer in the peripheral zone using multiparametric MRI
NASA Astrophysics Data System (ADS)
Niaf, Emilie; Rouvière, Olivier; Mège-Lechevallier, Florence; Bratan, Flavie; Lartizien, Carole
2012-06-01
This study evaluated a computer-assisted diagnosis (CADx) system for determining a likelihood measure of prostate cancer presence in the peripheral zone (PZ) based on multiparametric magnetic resonance (MR) imaging, including T2-weighted, diffusion-weighted and dynamic contrast-enhanced MRI at 1.5 T. Based on a feature set derived from grey-level images, including first-order statistics, Haralick features, gradient features, semi-quantitative and quantitative (pharmacokinetic modelling) dynamic parameters, four kinds of classifiers were trained and compared : nonlinear support vector machine (SVM), linear discriminant analysis, k-nearest neighbours and naïve Bayes classifiers. A set of feature selection methods based on t-test, mutual information and minimum-redundancy-maximum-relevancy criteria were also compared. The aim was to discriminate between the relevant features as well as to create an efficient classifier using these features. The diagnostic performances of these different CADx schemes were evaluated based on a receiver operating characteristic (ROC) curve analysis. The evaluation database consisted of 30 sets of multiparametric MR images acquired from radical prostatectomy patients. Using histologic sections as the gold standard, both cancer and nonmalignant (but suspicious) tissues were annotated in consensus on all MR images by two radiologists, a histopathologist and a researcher. Benign tissue regions of interest (ROIs) were also delineated in the remaining prostate PZ. This resulted in a series of 42 cancer ROIs, 49 benign but suspicious ROIs and 124 nonsuspicious benign ROIs. From the outputs of all evaluated feature selection methods on the test bench, a restrictive set of about 15 highly informative features coming from all MR sequences was discriminated, thus confirming the validity of the multiparametric approach. Quantitative evaluation of the diagnostic performance yielded a maximal area under the ROC curve (AUC) of 0.89 (0.81-0.94) for the discrimination of the malignant versus nonmalignant tissues and 0.82 (0.73-0.90) for the discrimination of the malignant versus suspicious tissues when combining the t-test feature selection approach with a SVM classifier. A preliminary comparison showed that the optimal CADx scheme mimicked, in terms of AUC, the human experts in differentiating malignant from suspicious tissues, thus demonstrating its potential for assisting cancer identification in the PZ.
Equity in Assistance? Usability of a U.S. Government Food Assistance Application
ERIC Educational Resources Information Center
Saal, Leah Katherine
2016-01-01
This article focuses on the quantitative phase of a multiphase mixed methods study investigating adults' and families' access to government food assistance. The research evaluates participants' comprehension of, and ability to, adequately complete authentic complex texts--national food assistance application documents. Summative usability testing…
The Organization and Evaluation of a Computer-Assisted, Centralized Immunization Registry.
ERIC Educational Resources Information Center
Loeser, Helen; And Others
1983-01-01
Evaluation of a computer-assisted, centralized immunization registry after one year shows that 93 percent of eligible health practitioners initially agreed to provide data and that 73 percent continue to do so. Immunization rates in audited groups have improved significantly. (GC)
Neural Coding for Effective Rehabilitation
2014-01-01
Successful neurological rehabilitation depends on accurate diagnosis, effective treatment, and quantitative evaluation. Neural coding, a technology for interpretation of functional and structural information of the nervous system, has contributed to the advancements in neuroimaging, brain-machine interface (BMI), and design of training devices for rehabilitation purposes. In this review, we summarized the latest breakthroughs in neuroimaging from microscale to macroscale levels with potential diagnostic applications for rehabilitation. We also reviewed the achievements in electrocorticography (ECoG) coding with both animal models and human beings for BMI design, electromyography (EMG) interpretation for interaction with external robotic systems, and robot-assisted quantitative evaluation on the progress of rehabilitation programs. Future rehabilitation would be more home-based, automatic, and self-served by patients. Further investigations and breakthroughs are mainly needed in aspects of improving the computational efficiency in neuroimaging and multichannel ECoG by selection of localized neuroinformatics, validation of the effectiveness in BMI guided rehabilitation programs, and simplification of the system operation in training devices. PMID:25258708
Assessing medical residents' usage and perceived needs for personal digital assistants.
Barrett, James R; Strayer, Scott M; Schubart, Jane R
2004-02-01
Health care professionals need information delivery tools for accessing information at the point of patient care. Personal digital assistants (PDAs), or hand-held devices demonstrate great promise as point of care information devices. An earlier study [The Constellation Project: experience and evaluation of personal digital assistants in the clinical environment, in: Proceedings of the 19th Annual Symposium on Computer Applications in Medical Care, 1995, 678] on the use of PDAs at the point of care found that hardware constraints, such as memory capability limited their usefulness, however, they were used frequently for accessing medical references and drug information [The Constellation Project: experience and evaluation of personal digital assistants in the clinical environment, in: Proceedings of the 19th Annual Symposium on Computer Applications in Medical Care, 1995, 678]. Since this study was completed in 1995, hand-held computer technology has advanced rapidly, and between 26 and 50% of physicians currently use PDAs [Physician's use of hand-helds increases from 15% in 1999 to 26% in 2001: Harris interactive poll results, Harris Poll. 8-24-2002 (electronic citation); ACP-ASIM survey finds nearly half of U.S. members use hand-held computers: ACP-ASIM press release, American College of Physicians, 9-3-2002 (electronic citation)]. This use appears higher among residents, with one recent study finding that over two-thirds of family practice residencies use hand-held computers in their training programs [J. Am. Med. Inform. Assoc. 9 (1) (2002) 80]. In this study, we systematically evaluate PDA usage by residents in our institution using quantitative and qualitative methods. Our evaluation included a brief on-line survey of 88 residents in seven residency programs including primary care and specialty practices. The surveys were completed between 26 October 2001 and 30 April 2002. Follow-up interviews with 15 of the surveyed residents were then conducted between 24 April 2002 and 13 May 2002. The original contributions of this study are the evaluation of residents in primary and specialty programs and evaluation of both medical application software and the conventional personal organizational software (such as calendars and to-do lists). This evaluation was also conducted using significantly advanced hardware and software compared with previous studies [The Constellation Project: experience and evaluation of personal digital assistants in the clinical environment, in: Proceedings of the 19th Annual Symposium on Computer Applications in Medical Care, 1995, 678]. Results of our survey and follow-up interviews of residents showed most residents use PDAs daily, regardless of practice or whether their program encourages PDAs. Uses include commercial medical references and personal organization software, such as calendars and address books. Concerns and drawbacks mentioned by these residents included physical size of the PDA and the potential for catastrophic data loss. Another issue raised by our results suggests that security and Health Information Portability and Accountability Act (HIPAA) compliance need to be addressed, in part by resident education about securing patient data on PDAs. Overall, PDAs may become even more widely used if two issues can be addressed: (a) providing secure clinical data for the current patients of a given resident, and (b) allaying concerns of catastrophic data loss from their PDAs (e.g. by educating residents about procedures to recover information from PDA backup files).
Evaluating biomarkers for prognostic enrichment of clinical trials.
Kerr, Kathleen F; Roth, Jeremy; Zhu, Kehao; Thiessen-Philbrook, Heather; Meisner, Allison; Wilson, Francis Perry; Coca, Steven; Parikh, Chirag R
2017-12-01
A potential use of biomarkers is to assist in prognostic enrichment of clinical trials, where only patients at relatively higher risk for an outcome of interest are eligible for the trial. We investigated methods for evaluating biomarkers for prognostic enrichment. We identified five key considerations when considering a biomarker and a screening threshold for prognostic enrichment: (1) clinical trial sample size, (2) calendar time to enroll the trial, (3) total patient screening costs and the total per-patient trial costs, (4) generalizability of trial results, and (5) ethical evaluation of trial eligibility criteria. Items (1)-(3) are amenable to quantitative analysis. We developed the Biomarker Prognostic Enrichment Tool for evaluating biomarkers for prognostic enrichment at varying levels of screening stringency. We demonstrate that both modestly prognostic and strongly prognostic biomarkers can improve trial metrics using Biomarker Prognostic Enrichment Tool. Biomarker Prognostic Enrichment Tool is available as a webtool at http://prognosticenrichment.com and as a package for the R statistical computing platform. In some clinical settings, even biomarkers with modest prognostic performance can be useful for prognostic enrichment. In addition to the quantitative analysis provided by Biomarker Prognostic Enrichment Tool, investigators must consider the generalizability of trial results and evaluate the ethics of trial eligibility criteria.
ERIC Educational Resources Information Center
Kwon, Oh-Woog; Lee, Kiyoung; Kim, Young-Kil; Lee, Yunkeun
2015-01-01
This paper introduces a Dialog-Based Computer-Assisted second-Language Learning (DB-CALL) system using semantic and grammar correctness evaluations and the results of its experiment. While the system dialogues with English learners about a given topic, it automatically evaluates the grammar and content properness of their English utterances, then…
ERIC Educational Resources Information Center
Seo, You-Jin; Woo, Honguk
2010-01-01
Critical user interface design features of computer-assisted instruction programs in mathematics for students with learning disabilities and corresponding implementation guidelines were identified in this study. Based on the identified features and guidelines, a multimedia computer-assisted instruction program, "Math Explorer", which delivers…
Automated quantitative assessment of proteins' biological function in protein knowledge bases.
Mayr, Gabriele; Lepperdinger, Günter; Lackner, Peter
2008-01-01
Primary protein sequence data are archived in databases together with information regarding corresponding biological functions. In this respect, UniProt/Swiss-Prot is currently the most comprehensive collection and it is routinely cross-examined when trying to unravel the biological role of hypothetical proteins. Bioscientists frequently extract single entries and further evaluate those on a subjective basis. In lieu of a standardized procedure for scoring the existing knowledge regarding individual proteins, we here report about a computer-assisted method, which we applied to score the present knowledge about any given Swiss-Prot entry. Applying this quantitative score allows the comparison of proteins with respect to their sequence yet highlights the comprehension of functional data. pfs analysis may be also applied for quality control of individual entries or for database management in order to rank entry listings.
Cost-Effectiveness of Alternative Approaches to Computer-Assisted Instruction.
ERIC Educational Resources Information Center
Levin, Henry M.; And Others
Operating on the premise that different approaches to computer-assisted instruction (CAI) may use different configurations of hardware and software, different curricula, and different organizational and personnel arrangements, this study explored the feasibility of collecting evaluations of CAI to evaluate the comparative cost-effectiveness of…
Nixon, Gavin J; Svenstrup, Helle F; Donald, Carol E; Carder, Caroline; Stephenson, Judith M; Morris-Jones, Stephen; Huggett, Jim F; Foy, Carole A
2014-12-01
Molecular diagnostic measurements are currently underpinned by the polymerase chain reaction (PCR). There are also a number of alternative nucleic acid amplification technologies, which unlike PCR, work at a single temperature. These 'isothermal' methods, reportedly offer potential advantages over PCR such as simplicity, speed and resistance to inhibitors and could also be used for quantitative molecular analysis. However there are currently limited mechanisms to evaluate their quantitative performance, which would assist assay development and study comparisons. This study uses a sexually transmitted infection diagnostic model in combination with an adapted metric termed isothermal doubling time (IDT), akin to PCR efficiency, to compare quantitative PCR and quantitative loop-mediated isothermal amplification (qLAMP) assays, and to quantify the impact of matrix interference. The performance metric described here facilitates the comparison of qLAMP assays that could assist assay development and validation activities.
Objective evaluation of hyperactivated motility in rat spermatozoa using computer-assisted sperm analysis.
Cancel AM, Lobdell D, Mendola P, Perreault SD.
Toxicology Program, University of North Carolina, Chapel Hill, NC 27599, USA.
The aim of this study was t...
ERIC Educational Resources Information Center
Payne, David A.
This case study presents a narrative summary of the evaluation of a two semester computer assisted instruction (CAI) project in an all minority high school. Use of PLATO software with Control Data microcomputers brought about modest achievement advantages, higher internal locus of control, more positive attitudes toward school and specific course…
Phenotypic characterization of glioblastoma identified through shape descriptors
NASA Astrophysics Data System (ADS)
Chaddad, Ahmad; Desrosiers, Christian; Toews, Matthew
2016-03-01
This paper proposes quantitatively describing the shape of glioblastoma (GBM) tissue phenotypes as a set of shape features derived from segmentations, for the purposes of discriminating between GBM phenotypes and monitoring tumor progression. GBM patients were identified from the Cancer Genome Atlas, and quantitative MR imaging data were obtained from the Cancer Imaging Archive. Three GBM tissue phenotypes are considered including necrosis, active tumor and edema/invasion. Volumetric tissue segmentations are obtained from registered T1˗weighted (T1˗WI) postcontrast and fluid-attenuated inversion recovery (FLAIR) MRI modalities. Shape features are computed from respective tissue phenotype segmentations, and a Kruskal-Wallis test was employed to select features capable of classification with a significance level of p < 0.05. Several classifier models are employed to distinguish phenotypes, where a leave-one-out cross-validation was performed. Eight features were found statistically significant for classifying GBM phenotypes with p <0.05, orientation is uninformative. Quantitative evaluations show the SVM results in the highest classification accuracy of 87.50%, sensitivity of 94.59% and specificity of 92.77%. In summary, the shape descriptors proposed in this work show high performance in predicting GBM tissue phenotypes. They are thus closely linked to morphological characteristics of GBM phenotypes and could potentially be used in a computer assisted labeling system.
A CAL-Based Undergraduate Genetics Course.
ERIC Educational Resources Information Center
Garbutt, K.; And Others
1979-01-01
Describes a second-year undergraduate practical course in quantitative genetics and biometrics, based upon computer-assisted learning (CAL); and discusses the educational benefits of the course, some problems encountered, and some implications of the extensive use of CAL. (Author/CMV)
Intelligent Computer Assisted Instruction (ICAI): Formative Evaluation of Two Systems
1986-03-01
appreciation .’.,-* for the power of computer technology. Interpretati on Yale students are a strikingly high performing group by traditional academic ...COMPUTER ASSISTED INSTRUCTION April 1984 - August 1985 (ICAI): FORMATIVE EVALUATION OF TWO SYSTEMS 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(*) S...956881 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK AREA & WORK UNIT NUMBERS Jet Propulsion Laboratory 2Q263743A794
Computer-assisted revision total knee replacement.
Sikorski, J M
2004-05-01
A technique for performing allograft-augmented revision total knee replacement (TKR) using computer assistance is described, on the basis of the results in 14 patients. Bone deficits were made up with impaction grafting. Femoral grafting was made possible by the construction of a retaining wall or dam which allowed pressurisation and retention of the graft. Tibial grafting used a mixture of corticocancellous and morsellised allograft. The position of the implants was monitored by the computer system and adjusted while the cement was setting. The outcome was determined using a six-parameter, quantitative technique (the Perth CT protocol) which measured the alignment of the prosthesis and provided an objective score. The final outcomes were not perfect with errors being made in femoral rotation and in producing a mismatch between the femoral and tibial components. In spite of the shortcomings the alignments were comparable in accuracy with those after primary TKR. Computer assistance shows considerable promise in producing accurate alignment in revision TKR with bone deficits.
ERIC Educational Resources Information Center
Deignan, Gerard M.; And Others
This report contains a comparative analysis of the differential effectiveness of computer-assisted instruction (CAI), programmed instructional text (PIT), and lecture methods of instruction in three medical courses--Medical Laboratory, Radiology, and Dental. The summative evaluation includes (1) multiple regression analyses conducted to predict…
ERIC Educational Resources Information Center
Bruce, A. Wayne
1986-01-01
Describes reasons for developing combined text and computer assisted instruction (CAI) teaching programs for delivery of continuing education to laboratory professionals, and mechanisms used for developing a CAI program on method evaluation in the clinical laboratory. Results of an evaluation of the software's cost effectiveness and instructional…
Li, Zhi; Yang, Rong-Tao; Li, Zu-Bing
2015-09-01
Computer-assisted navigation has been widely used in oral and maxillofacial surgery. The purpose of this study was to describe the applications of computer-assisted navigation for the minimally invasive reduction of isolated zygomatic arch fractures. All patients identified as having isolated zygomatic arch fractures presenting to the authors' department from April 2013 through November 2014 were included in this prospective study. Minimally invasive reductions of isolated zygomatic arch fractures were performed on these patients under the guidance of computer-assisted navigation. The reduction status was evaluated by postoperative computed tomography (CT) 1 week after the operation. Postoperative complications and facial contours were evaluated during follow-up. Functional recovery was evaluated by the difference between the preoperative maximum interincisal mouth opening and that at the final follow-up. Twenty-three patients were included in this case series. The operation proceeded well in all patients. Postoperatively, all patients displayed uneventful healing without postoperative complication. Postoperative CT showed exact reduction in all cases. Satisfactory facial contour and functional recovery were observed in all patients. The preoperative maximal mouth opening ranged from 8 to 25 mm, and the maximal mouth opening at the final follow-up ranged from 36 to 42 mm. Computer-assisted navigation can be used not only for guiding zygomatic arch fracture reduction, but also for assessing reduction. Computer-assisted navigation is an effective and minimally invasive technique that can be applied in the reduction of isolated zygomatic arch fractures. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Computer-assisted qualitative data analysis software.
Cope, Diane G
2014-05-01
Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.
Kuhl, Mitchell; Beimel, Claudia
2016-10-01
The goal of this study was to evaluate the ability of a novel computer assisted surgery system to guide ideal placement of a lag screw during cephalomedullary nailing and then accurately measure the tip-apex distance (TAD) measurement intraoperatively. Retrospective case review. Level II trauma hospital. The initial 98 consecutive clinical cases treated with a cephalomedullary nail in conjunction with a novel computer assisted surgery system were retrospectively reviewed. A novel computer assisted surgery system was utilized to enhance lag screw placement during cephalomedullary nailing procedures. The computer assisted surgery system calculates the TAD intraoperatively after final lag screw placement. The ideal TAD was considered to be within a range of 5mm-20mm. The ability of the computer assisted surgery system (CASS) to assist in placement of a lag screw within the ideal TAD was evaluated. Intraoperative TAD measurements provided by the computer assisted surgery system were then compared to standard postoperative TAD measurements on PACS (picture archiving and communication system) images to determine whether these measurements are equivalent. 79 cases (80.6%) were available with complete information for a retrospective review. All cases had CASS TAD and PACS TAD measurements >5mm and<20mm. In addition, no significant difference could be detected between the intraoperative CASS TAD and the postoperative PACS TAD (p=0.374, Wilcoxon Test; p=0.174, paired T-Test). A cut-out rate of 0% was observed in all patients who were treated with CASS in this case series (95% CI: 0 - 3.01%). The novel computer assisted surgery system tested here is an effective and reliable adjunct that can be utilized for optimal lag screw placement in cephalomedullary nailing procedures. The computer assisted surgery system provides an accurate intraoperative TAD measurement that is equivalent to the standard postoperative measurement utilizing PACS images. Therapeutic Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Baker, Eva L.
Some special problems associated with evaluating intelligent computer-assisted instruction (ICAI) programs are addressed. This paper intends to describe alternative approaches to the assessment and improvement of such applications and to provide examples of efforts undertaken and shortfalls. Issues discussed stem chiefly from the technical demands…
ERIC Educational Resources Information Center
Pennington, Robert C.; Ault, Melinda Jones; Schuster, John W.; Sanders, Ann
2011-01-01
In the current study, the researchers evaluated the effects of simultaneous prompting and computer-assisted instruction on the story-writing responses of 3 males with autism, 7 to 10 ears of age. Classroom teachers conducted all probe and training sessions. The researchers used a multiple baseline across participants design to evaluate the…
ERIC Educational Resources Information Center
Harris, Carolyn DeMeyer; And Others
Dolphin is a computer-assisted instruction system used to teach and reinforce skills in reading, language arts, and mathematics. An evaluation of this system was conducted to provide information to TSC Division of Houghton Mifflin regarding its effectiveness and possible modifications to the system. The general design of the evaluation was to…
Quantitative morphometrical characterization of human pronuclear zygotes.
Beuchat, A; Thévenaz, P; Unser, M; Ebner, T; Senn, A; Urner, F; Germond, M; Sorzano, C O S
2008-09-01
Identification of embryos with high implantation potential remains a challenge in in vitro fertilization (IVF). Subjective pronuclear (PN) zygote scoring systems have been developed for that purpose. The aim of this work was to provide a software tool that enables objective measuring of morphological characteristics of the human PN zygote. A computer program was created to analyse zygote images semi-automatically, providing precise morphological measurements. The accuracy of this approach was first validated by comparing zygotes from two different IVF centres with computer-assisted measurements or subjective scoring. Computer-assisted measurement and subjective scoring were then compared for their ability to classify zygotes with high and low implantation probability by using a linear discriminant analysis. Zygote images coming from the two IVF centres were analysed with the software, resulting in a series of precise measurements of 24 variables. Using subjective scoring, the cytoplasmic halo was the only feature which was significantly different between the two IVF centres. Computer-assisted measurements revealed significant differences between centres in PN centring, PN proximity, cytoplasmic halo and features related to nucleolar precursor bodies distribution. The zygote classification error achieved with the computer-assisted measurements (0.363) was slightly inferior to that of the subjective ones (0.393). A precise and objective characterization of the morphology of human PN zygotes can be achieved by the use of an advanced image analysis tool. This computer-assisted analysis allows for a better morphological characterization of human zygotes and can be used for classification.
ERIC Educational Resources Information Center
Jenny, Ng Yuen Yee; Fai, Tam Sing
2001-01-01
A study compared 48 cardiac patients who used an interactive multimedia computer-assisted patient education program and 48 taught by tutorial. The computer-assisted instructional method resulted in significantly better knowledge about exercise and self-management of chronic diseases. (Contains 29 references.) (JOW)
The Application of Learning Styles to Computer Assisted Instruction in Nursing Education
1991-01-01
nursing profession is to integrate computer technology into the learning process at all levels of nursing education . In order to successfully accomplish... learning styles. * Computer technology needs to be integrated into nursing education , research and practice. * * An evaluation tool needs to be...Computer-assisted video instruction Learning Styles and CAI 71 References Aiken, E. (1990). Continuing nursing education in computer technology : A regional
Incorporation of CAD/CAM Restoration Into Navy Dentistry
2017-09-26
CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct
Timothy J. Murray; Daniel J. Bisenius; Jay G. Marcotte
1979-01-01
A computer-assisted method was used to locate and evaluate approximately 1,200 miles of alternative corridors within an 8,000 square mile study region. The method involved in-depth impact analyses for nine major location criteria or determinant models. Regional "experts" from the Rocky Mountain area participated with BPA in developing model structure....
Model-assisted development of a laminography inspection system
NASA Astrophysics Data System (ADS)
Grandin, R.; Gray, J.
2012-05-01
Traditional computed tomography (CT) is an effective method of determining the internal structure of an object through non-destructive means; however, inspection of certain objects, such as those with planar geometrics or with limited access, requires an alternate approach. An alternative is laminography and has been the focus of a number of researchers in the past decade for both medical and industrial inspections. Many research efforts rely on geometrically-simple analytical models, such as the Shepp-Logan phantom, for the development of their algorithms. Recent work at the Center for Non-Destructive Evaluation makes extensive use of a forward model, XRSIM, to study artifacts arising from the reconstruction method, the effects of complex geometries and known issues such as high density features on the laminography reconstruction process. The use of a model provides full knowledge of all aspects of the geometry and provides a means to quantitatively evaluate the impact of methods designed to reduce artifacts generated by the reconstruction methods or that are result of the part geometry. We will illustrate the use of forward simulations to quantitatively assess reconstruction algorithm development and artifact reduction.
Evaluating conflation methods using uncertainty modeling
NASA Astrophysics Data System (ADS)
Doucette, Peter; Dolloff, John; Canavosio-Zuzelski, Roberto; Lenihan, Michael; Motsko, Dennis
2013-05-01
The classic problem of computer-assisted conflation involves the matching of individual features (e.g., point, polyline, or polygon vectors) as stored in a geographic information system (GIS), between two different sets (layers) of features. The classical goal of conflation is the transfer of feature metadata (attributes) from one layer to another. The age of free public and open source geospatial feature data has significantly increased the opportunity to conflate such data to create enhanced products. There are currently several spatial conflation tools in the marketplace with varying degrees of automation. An ability to evaluate conflation tool performance quantitatively is of operational value, although manual truthing of matched features is laborious and costly. In this paper, we present a novel methodology that uses spatial uncertainty modeling to simulate realistic feature layers to streamline evaluation of feature matching performance for conflation methods. Performance results are compiled for DCGIS street centerline features.
ERIC Educational Resources Information Center
Jenkins, Craig
2015-01-01
This paper is a comparative quantitative evaluation of an approach to teaching poetry in the subject domain of English that employs a "guided discovery" pedagogy using computer-based microworlds. It uses a quasi-experimental design in order to measure performance gains in computational thinking and poetic thinking following a…
ERIC Educational Resources Information Center
Ferguson, Richard L.
The focus of this study was upon the development and evaluation of a computer-assisted branched test to be used in making instructional decisions for individuals in the program of Individually Prescribed Instruction. A Branched Test is one in which the presentation of test items is contingent upon the previous responses of the examinee. The…
ERIC Educational Resources Information Center
Gauggel, S.; Niemann, T.
1996-01-01
This study evaluated a computer-assisted training program used by four patients (ages 40 to 53) who had attentional deficits caused by cerebrovascular accident and closed head injury. Patients demonstrated improvements in training tasks, attention, and visual memory, but no improvements in two verbal memory tests and a general intelligence test.…
ERIC Educational Resources Information Center
McLeod, Sharynne; Baker, Elise; McCormack, Jane; Wren, Yvonne; Roulstone, Sue; Crowe, Kathryn; Masso, Sarah; White, Paul; Howland, Charlotte
2017-01-01
Purpose: The aim was to evaluate the effectiveness of computer-assisted input-based intervention for children with speech sound disorders (SSD). Method: The Sound Start Study was a cluster-randomized controlled trial. Seventy-nine early childhood centers were invited to participate, 45 were recruited, and 1,205 parents and educators of 4- and…
ERIC Educational Resources Information Center
Mitzel, Harold E.
A computer-assisted instruction course in the recognition of malarial parasites was developed and evaluated. The course includes stage discrimination, species discrimination, and case histories. Segments developed use COURSEWRITER as an author language and are presented via a display terminal that permits two-way communication with an IBM computer…
WINCADRE (COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed ...
NASA Astrophysics Data System (ADS)
Bizyuk, S. A.; Istomin, Yu. P.; Dzhagarov, B. M.
2006-07-01
We have developed a procedure for analysis of the functional status of blood vessels in tumor tissues using computer-assisted color scanning of tumor slices and also for a quantitative assessment of the effectiveness of photoinduced destruction of tumor tissues in animal experiments. Its major advantage is direct determination of the size of the tumor necrosis zone. The procedure has been tested in an experiment on three strains of malignant tumors with different morphologies.
ERIC Educational Resources Information Center
Stultz, Sherry L.
2017-01-01
This review was conducted to evaluate the current body of scholarly research regarding the use of computer-assisted instruction (CAI) to teach mathematics to students with specific learning disability (SLD). For many years, computers are utilized for educational purposes. However, the effectiveness of CAI for teaching mathematics to this specific…
ERIC Educational Resources Information Center
Soliman, Mamdouh M.; Hilal, Ahmed J.
2016-01-01
This study evaluates the effectiveness of Computer-Assisted Instruction (CAI) compared with traditional classroom instruction of mathematics of seventh graders in Kuwait's public schools. We aimed to compare students learning outcomes between two groups: the control group, taught traditionally without the use of computers, and the experimental…
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru
2008-03-01
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
Learning to consult with computers.
Liaw, S T; Marty, J J
2001-07-01
To develop and evaluate a strategy to teach skills and issues associated with computers in the consultation. An overview lecture plus a workshop before and a workshop after practice placements, during the 10-week general practice (GP) term in the 5th year of the University of Melbourne medical course. Pre- and post-intervention study using a mix of qualitative and quantitative methods within a strategic evaluation framework. Self-reported attitudes and skills with clinical applications before, during and after the intervention. Most students had significant general computer experience but little in the medical area. They found the workshops relevant, interesting and easy to follow. The role-play approach facilitated students' learning of relevant communication and consulting skills and an appreciation of issues associated with using the information technology tools in simulated clinical situations to augment and complement their consulting skills. The workshops and exposure to GP systems were associated with an increase in the use of clinical software, more realistic expectations of existing clinical and medical record software and an understanding of the barriers to the use of computers in the consultation. The educational intervention assisted students to develop and express an understanding of the importance of consulting and communication skills in teaching and learning about medical informatics tools, hardware and software design, workplace issues and the impact of clinical computer systems on the consultation and patient care.
Edwards, Roger L; Edwards, Sandra L; Bryner, James; Cunningham, Kelly; Rogers, Amy; Slattery, Martha L
2008-04-01
We describe a computer-assisted data collection system developed for a multicenter cohort study of American Indian and Alaska Native people. The study computer-assisted participant evaluation system or SCAPES is built around a central database server that controls a small private network with touch screen workstations. SCAPES encompasses the self-administered questionnaires, the keyboard-based stations for interviewer-administered questionnaires, a system for inputting medical measurements, and administrative tasks such as data exporting, backup and management. Elements of SCAPES hardware/network design, data storage, programming language, software choices, questionnaire programming including the programming of questionnaires administered using audio computer-assisted self-interviewing (ACASI), and participant identification/data security system are presented. Unique features of SCAPES are that data are promptly made available to participants in the form of health feedback; data can be quickly summarized for tribes for health monitoring and planning at the community level; and data are available to study investigators for analyses and scientific evaluation.
Calibrated Peer Review for Computer-Assisted Learning of Biological Research Competencies
ERIC Educational Resources Information Center
Clase, Kari L.; Gundlach, Ellen; Pelaez, Nancy J.
2010-01-01
Recently, both science and technology faculty have been recognizing biological research competencies that are valued but rarely assessed. Some of these valued learning outcomes include scientific methods and thinking, critical assessment of primary papers, quantitative reasoning, communication, and putting biological research into a historical and…
ERIC Educational Resources Information Center
Kaousar, Tayyeba; Choudhry, Bushra Naoreen; Gujjar, Aijaz Ahmed
2008-01-01
This study was aimed to evaluate the effectiveness of CAI vs. classroom lecture for computer science at ICS level. The objectives were to compare the learning effects of two groups with classroom lecture and computer-assisted instruction studying the same curriculum and the effects of CAI and CRL in terms of cognitive development. Hypotheses of…
ERIC Educational Resources Information Center
Hasenekoglu, Ismet; Timucin, Melih
2007-01-01
The aim of this study is to collect and evaluate opinions of CAI experts and biology teachers about a high school level Computer Assisted Biology Instruction Material presenting computer-made modelling and simulations. It is a case study. A material covering "Nucleic Acids and Protein Synthesis" topic was developed as the…
ERIC Educational Resources Information Center
Zuberman, Lea K.
This critical review and evaluation of the literature covers the field of computer assisted instruction (CAI) and reading from its inception to the present day. Seventeen research studies are discussed as well as four surveys of previous research in this field. Major issues addressed include the effectiveness of CAI and computer managed…
WINCADRE INORGANIC (WINDOWS COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed in...
Using computer assisted learning for clinical skills education in nursing: integrative review.
Bloomfield, Jacqueline G; While, Alison E; Roberts, Julia D
2008-08-01
This paper is a report of an integrative review of research investigating computer assisted learning for clinical skills education in nursing, the ways in which it has been studied and the general findings. Clinical skills are an essential aspect of nursing practice and there is international debate about the most effective ways in which these can be taught. Computer assisted learning has been used as an alternative to conventional teaching methods, and robust research to evaluate its effectiveness is essential. The CINAHL, Medline, BNI, PsycInfo and ERIC electronic databases were searched for the period 1997-2006 for research-based papers published in English. Electronic citation tracking and hand searching of reference lists and relevant journals was also undertaken. Twelve studies met the inclusion criteria. An integrative review was conducted and each paper was explored in relation to: design, aims, sample, outcome measures and findings. Many of the study samples were small and there were weaknesses in designs. There is limited empirical evidence addressing the use of computer assisted learning for clinical skills education in nursing. Computer assisted learning has been used to teach a limited range of clinical skills in a variety of settings. The paucity of evaluative studies indicates the need for more rigorous research to investigate the effect of computer assisted learning for this purpose. Areas that need to be addressed in future studies include: sample size, range of skills, longitudinal follow-up and control of confounding variables.
Effect of ram semen extenders and supplements on computer assisted sperm analysis parameters
USDA-ARS?s Scientific Manuscript database
A study evaluated the effects of ram semen extender and extender supplementation on computer assisted sperm analysis (CASA) parameters positively correlated with progressive motility. Semen collected from 5 rams was distributed across treatment combinations consisting of either TRIS citrate (T) or ...
Computer Aided Instruction in Teaching Program Evaluation.
ERIC Educational Resources Information Center
Dowell, David A.; Binette, Holly A. Lizotte
This paper reports the results of two semesters of experience using computer-assisted instruction (CAI) to teach topics in program evaluation to undergraduate and graduate psychology students at California State University, Long Beach. (The topics addressed are models of evaluation, evaluability assessment, needs assessment, experimental and…
Radiomic analysis in prediction of Human Papilloma Virus status.
Yu, Kaixian; Zhang, Youyi; Yu, Yang; Huang, Chao; Liu, Rongjie; Li, Tengfei; Yang, Liuqing; Morris, Jeffrey S; Baladandayuthapani, Veerabhadran; Zhu, Hongtu
2017-12-01
Human Papilloma Virus (HPV) has been associated with oropharyngeal cancer prognosis. Traditionally the HPV status is tested through invasive lab test. Recently, the rapid development of statistical image analysis techniques has enabled precise quantitative analysis of medical images. The quantitative analysis of Computed Tomography (CT) provides a non-invasive way to assess HPV status for oropharynx cancer patients. We designed a statistical radiomics approach analyzing CT images to predict HPV status. Various radiomics features were extracted from CT scans, and analyzed using statistical feature selection and prediction methods. Our approach ranked the highest in the 2016 Medical Image Computing and Computer Assisted Intervention (MICCAI) grand challenge: Oropharynx Cancer (OPC) Radiomics Challenge, Human Papilloma Virus (HPV) Status Prediction. Further analysis on the most relevant radiomic features distinguishing HPV positive and negative subjects suggested that HPV positive patients usually have smaller and simpler tumors.
Correcting Spellings in Second Language Learners' Computer-Assisted Collaborative Writing
ERIC Educational Resources Information Center
Musk, Nigel
2016-01-01
The present study uses multimodal conversation analysis to examine how pupils studying English as a foreign language make spelling corrections in real time while doing collaborative computer-assisted project work. Unlike most previous related investigations, this study focuses on the "process" rather than evaluating the final…
A College-Level, Computer-Assisted Course in Nutrition.
ERIC Educational Resources Information Center
Carew, Lyndon B.; And Others
1984-01-01
Describes a computer-assisted instructional (CAI) program to accompany a 15-week, college-level, introductory lecture course on the scientific principles of mammalian nutrition. The nature of the program is discussed, and examples of how it operates are provided. Comments on the evaluation of the program are also provided. (JN)
A Longitudinal Evaluation of Computer-Assisted Instruction on Contraception for College Students.
ERIC Educational Resources Information Center
Reis, Janet; Tymchyshyn, Patricia
1992-01-01
Assessed changes in contraceptive knowledge of 58 white female undergraduate students following computer-assisted instruction program on contraception. At six-month follow-up, students evidenced knowledge gains on duration of pill use, rationale for triphasics and biphasics, appropriate contingencies for missing two days of pill, danger signs…
Tutoring with Alphie: Evaluation Report and Executive Summary
ERIC Educational Resources Information Center
Biggart, Andy; O'Hare, Liam; Miller, Sarah
2015-01-01
Tutoring with Alphie is a computer-assisted programme that aims to improve the literacy skills of struggling readers. The programme combines elements of collaborative (or 'cooperative') learning, computer-assisted instruction and small group support. Participating pupils are grouped in pairs and follow a series of activities that seek to improve…
ERIC Educational Resources Information Center
Liu, Sze-Chu; Hung, Po-Yi
2016-01-01
The purpose of this study is to evaluate the effectiveness of computer assisted pronunciation instruction in English pronunciation for students in vocational colleges and universities in Taiwan. The participants were fifty-one first-year undergraduate students from a technological university located in central Taiwan. The participants received an…
Computer-assisted design in perceptual-motor skills research
NASA Technical Reports Server (NTRS)
Rogers, C. A., Jr.
1974-01-01
A categorization was made of independent variables previously found to be potent in simple perceptual-motor tasks. A computer was then used to generate hypothetical factorial designs. These were evaluated in terms of literature trends and pragmatic criteria. Potential side-effects of machine-assisted research strategy were discussed.
DAWN (Design Assistant Workstation) for advanced physical-chemical life support systems
NASA Technical Reports Server (NTRS)
Rudokas, Mary R.; Cantwell, Elizabeth R.; Robinson, Peter I.; Shenk, Timothy W.
1989-01-01
This paper reports the results of a project supported by the National Aeronautics and Space Administration, Office of Aeronautics and Space Technology (NASA-OAST) under the Advanced Life Support Development Program. It is an initial attempt to integrate artificial intelligence techniques (via expert systems) with conventional quantitative modeling tools for advanced physical-chemical life support systems. The addition of artificial intelligence techniques will assist the designer in the definition and simulation of loosely/well-defined life support processes/problems as well as assist in the capture of design knowledge, both quantitative and qualitative. Expert system and conventional modeling tools are integrated to provide a design workstation that assists the engineer/scientist in creating, evaluating, documenting and optimizing physical-chemical life support systems for short-term and extended duration missions.
NASA Astrophysics Data System (ADS)
Konstantinov, M. S.; Orlov, A. A.
2014-12-01
The paper analyzes the possibility of the use of a gravity-assist maneuver for flight to Jupiter. The advantage of the Earth gravity-assist maneuver in comparison with the direct transfer in terms of reduction of amount of energy required per transfer is considered. Quantitative and qualitative evaluations of two transfer profiles are given.
Accuracy in planar cutting of bones: an ISO-based evaluation.
Cartiaux, Olivier; Paul, Laurent; Docquier, Pierre-Louis; Francq, Bernard G; Raucent, Benoît; Dombre, Etienne; Banse, Xavier
2009-03-01
Computer- and robot-assisted technologies are capable of improving the accuracy of planar cutting in orthopaedic surgery. This study is a first step toward formulating and validating a new evaluation methodology for planar bone cutting, based on the standards from the International Organization for Standardization. Our experimental test bed consisted of a purely geometrical model of the cutting process around a simulated bone. Cuts were performed at three levels of surgical assistance: unassisted, computer-assisted and robot-assisted. We measured three parameters of the standard ISO1101:2004: flatness, parallelism and location of the cut plane. The location was the most relevant parameter for assessing cutting errors. The three levels of assistance were easily distinguished using the location parameter. Our ISO methodology employs the location to obtain all information about translational and rotational cutting errors. Location may be used on any osseous structure to compare the performance of existing assistance technologies.
Estimating the Reliability of the CITAR Computer Courseware Evaluation System.
ERIC Educational Resources Information Center
Micceri, Theodore
In today's complex computer-based teaching (CBT)/computer-assisted instruction market, flashy presentations frequently prove the most important purchasing element, while instructional design and content are secondary to form. Courseware purchasers must base decisions upon either a vendor's presentation or some published evaluator rating.…
Gao, Kun; Zhou, Linyan; Bi, Jinfeng; Yi, Jianyong; Wu, Xinye; Zhou, Mo; Wang, Xueyuan; Liu, Xuan
2017-06-01
Computer vision-based image analysis systems are widely used in food processing to evaluate quality changes. They are able to objectively measure the surface colour of various products since, providing some obvious advantages with their objectivity and quantitative capabilities. In this study, a computer vision-based image analysis system was used to investigate the colour changes of apple slices dried by instant controlled pressure drop-assisted hot air drying (AD-DIC). The CIE L* value and polyphenol oxidase activity in apple slices decreased during the entire drying process, whereas other colour indexes, including CIE a*, b*, ΔE and C* values, increased. The browning ratio calculated by image analysis increased during the drying process, and a sharp increment was observed for the DIC process. The change in 5-hydroxymethylfurfural (5-HMF) and fluorescent compounds (FIC) showed the same trend with browning ratio due to Maillard reaction. Moreover, the concentrations of 5-HMF and FIC both had a good quadratic correlation (R 2 > 0.998) with the browning ratio. Browning ratio was a reliable indicator of 5-HMF and FIC changes in apple slices during drying. The image analysis system could be used to monitor colour changes, 5-HMF and FIC in dehydrated apple slices during the AD-DIC process. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Zheng, Guoyan; Chu, Chengwen; Belavý, Daniel L; Ibragimov, Bulat; Korez, Robert; Vrtovec, Tomaž; Hutt, Hugo; Everson, Richard; Meakin, Judith; Andrade, Isabel Lŏpez; Glocker, Ben; Chen, Hao; Dou, Qi; Heng, Pheng-Ann; Wang, Chunliang; Forsberg, Daniel; Neubert, Aleš; Fripp, Jurgen; Urschler, Martin; Stern, Darko; Wimmer, Maria; Novikov, Alexey A; Cheng, Hui; Armbrecht, Gabriele; Felsenberg, Dieter; Li, Shuo
2017-01-01
The evaluation of changes in Intervertebral Discs (IVDs) with 3D Magnetic Resonance (MR) Imaging (MRI) can be of interest for many clinical applications. This paper presents the evaluation of both IVD localization and IVD segmentation methods submitted to the Automatic 3D MRI IVD Localization and Segmentation challenge, held at the 2015 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI2015) with an on-site competition. With the construction of a manually annotated reference data set composed of 25 3D T2-weighted MR images acquired from two different studies and the establishment of a standard validation framework, quantitative evaluation was performed to compare the results of methods submitted to the challenge. Experimental results show that overall the best localization method achieves a mean localization distance of 0.8 mm and the best segmentation method achieves a mean Dice of 91.8%, a mean average absolute distance of 1.1 mm and a mean Hausdorff distance of 4.3 mm, respectively. The strengths and drawbacks of each method are discussed, which provides insights into the performance of different IVD localization and segmentation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Zheng, Lanqin; Huang, Ronghuai; Hwang, Gwo-Jen; Yang, Kaicheng
2015-01-01
The purpose of this study is to quantitatively measure the level of knowledge elaboration and explore the relationships between prior knowledge of a group, group performance, and knowledge elaboration in collaborative learning. Two experiments were conducted to investigate the level of knowledge elaboration. The collaborative learning objective in…
Quantitative morphology in canine cutaneous soft tissue sarcomas.
Simeonov, R; Ananiev, J; Gulubova, M
2015-12-01
Stained cytological specimens from 24 dogs with spontaneous soft tissue sarcomas [fibrosarcoma (n = 8), liposarcoma (n = 8) and haemangiopericytoma (n = 8)], and 24 dogs with reactive connective tissue lesions [granulation tissue (n = 12) and dermal fibrosis (n = 12)] were analysed by computer-assisted nuclear morphometry. The studied morphometric parameters were: mean nuclear area (MNA; µm(2)), mean nuclear perimeter (MNP; µm), mean nuclear diameter (MND mean; µm), minimum nuclear diameter (Dmin; µm) and maximum nuclear diameter (Dmax; µm). The study aimed to evaluate (1) possibility for quantitative differentiation of soft tissue sarcomas from reactive connective tissue lesions and (2) by using cytomorphometry, to differentiate the various histopathological soft tissue sarcomas subtypes in dogs. The mean values of all nuclear cytomorphometric parameters (except for Dmax) were statistically significantly higher in reactive connective tissue processes than in soft tissue sarcomas. At the same time, however, there were no considerable differences among the different sarcoma subtypes. The results demonstrated that the quantitative differentiation of reactive connective tissue processes from soft tissue sarcomas in dogs is possible, but the same was not true for the different canine soft tissue sarcoma subtypes. Further investigations on this topic are necessary for thorough explication of the role of quantitative morphology in the diagnostics of mesenchymal neoplasms and tumour-like fibrous lesions in dogs. © 2014 John Wiley & Sons Ltd.
ASPECTS: an automation-assisted SPE method development system.
Li, Ming; Chou, Judy; King, Kristopher W; Yang, Liyu
2013-07-01
A typical conventional SPE method development (MD) process usually involves deciding the chemistry of the sorbent and eluent based on information about the analyte; experimentally preparing and trying out various combinations of adsorption chemistry and elution conditions; quantitatively evaluating the various conditions; and comparing quantitative results from all combination of conditions to select the best condition for method qualification. The second and fourth steps have mostly been performed manually until now. We developed an automation-assisted system that expedites the conventional SPE MD process by automating 99% of the second step, and expedites the fourth step by automatically processing the results data and presenting it to the analyst in a user-friendly format. The automation-assisted SPE MD system greatly saves the manual labor in SPE MD work, prevents analyst errors from causing misinterpretation of quantitative results, and shortens data analysis and interpretation time.
Miksztai-Réthey, Brigitta; Faragó, Kinga Bettina
2015-01-01
We studied an artificial intelligent assisted interaction between a computer and a human with severe speech and physical impairments (SSPI). In order to speed up AAC, we extended a former study of typing performance optimization using a framework that included head movement controlled assistive technology and an onscreen writing device. Quantitative and qualitative data were collected and analysed with mathematical methods, manual interpretation and semi-supervised machine video annotation. As the result of our research, in contrast to the former experiment's conclusions, we found that our participant had at least two different typing strategies. To maximize his communication efficiency, a more complex assistive tool is suggested, which takes the different methods into consideration.
Boltri, Matteo; Magri, Vittorio; Montanari, Emanuele; Perletti, Gianpaolo; Trinchieri, Alberto
2018-04-26
The aim of this study was the development of quantitative assessment of prostatic calcifications at prostatic ultrasound examination by the use of an image analyzer. A group of 82 patients was evaluated by medical history, physical, and transrectal ultrasound examination. Patients had a urethral swab, a 4-specimen study and culture of the seminal fluid. Patients were classified according to National Institute of Diabetes and Digestive and Kidney Diseases/National Institutes of Health. Subjective symptoms were scored by Chronic Prostatitis Symptom Index (CPSI) questionnaire. Ultrasound images were analyzed by the digital processing software Image J to quantitatively assess the presence of calcifications. Computer-assessed calcified areas were significantly higher in chronic bacterial prostatitis (n = 18; group II; 6.76 ± 8.09%) than in the chronic pelvic pain syndrome group IIIa (n = 26; 2.07 ± 1.01%) and IIIb (n = 38; 2.31 ± 2.18%). The area of calcification of the prostate was significantly related to the CPSI score for domains of micturition (r = 0.278, p = 0.023), Prostatic Specific Antigen values (r = 0341, p = 0.005), postvoiding residual urine (r = 0.262, p = 0.032), total prostate volume (r = 0.592, p = 0.000), and adenoma volume (r = 0.593; p = 0.000). The presence of calcifications is more frequently observed in patients with chronic bacterial prostatitis and is related to urinary symptoms. © 2018 S. Karger AG, Basel.
Longitudinal Evaluation of the Computer Assisted Instruction, Title I Project, 1979-82.
ERIC Educational Resources Information Center
Lavin, Richard J.; Sanders, Jean E.
The Computer-Assisted Instruction (CAI) Project is an alternative, supplementary approach to providing reading, mathematics, and language arts instruction in schools in six northeastern Massachusetts communities. The CAI activities are provided as a supplement to instruction in Title I/Chapter I programs. Beginning in 1979, a 3-year research study…
A PERT/CPM of the Computer Assisted Completion of The Ministry September Report. Research Report.
ERIC Educational Resources Information Center
Feeney, J. D.
Using two statistical analysis techniques (the Program Evaluation and Review Technique and the Critical Path Method), this study analyzed procedures for compiling the required yearly report of the Metropolitan Separate School Board (Catholic) of Toronto, Canada. The computer-assisted analysis organized the process of completing the report more…
Evaluation of DILearn: An Interactive Computer-Assisted Learning Program for Drug Information.
ERIC Educational Resources Information Center
Tunget, Cynthia L.; And Others
1993-01-01
Use of an interactive computer-assisted learning program to teach basic skills in obtaining drug information was investigated with 26 doctoral pharmacy students and a control group of 25 students receiving lecture instruction. Findings indicated no significant differences in short-term retention of drug information between groups and that students…
ERIC Educational Resources Information Center
Longberg, Pauline Oliphant
2012-01-01
As computer assisted instruction (CAI) becomes increasingly sophisticated, its appeal as a viable method of literacy intervention with young children continues despite limited evidence of effectiveness. The present study sought to assess the impact of one such CAI program, "Imagine Learning English" (ILE), on both the receptive…
ERIC Educational Resources Information Center
Jha, Vikram; Widdowson, Shelley; Duffy, Sean
2002-01-01
Discusses computer-assisted learning (CAL) in medical education and describes the development of an interactive CAL program on CD-ROM, combining video, illustrations, and three-dimensional images, to enhance understanding of vaginal hysterectomy in terms of the anatomy and steps of the surgical procedure. (Author/LRW)
Computer measurement of arterial disease
NASA Technical Reports Server (NTRS)
Armstrong, J.; Selzer, R. H.; Barndt, R.; Blankenhorn, D. H.; Brooks, S.
1980-01-01
Image processing technique quantifies human atherosclerosis by computer analysis of arterial angiograms. X-ray film images are scanned and digitized, arterial shadow is tracked, and several quantitative measures of lumen irregularity are computed. In other tests, excellent agreement was found between computer evaluation of femoral angiograms on living subjects and evaluation by teams of trained angiographers.
Advances in Integrated Computational Materials Engineering "ICME"
NASA Astrophysics Data System (ADS)
Hirsch, Jürgen
The methods of Integrated Computational Materials Engineering that were developed and successfully applied for Aluminium have been constantly improved. The main aspects and recent advances of integrated material and process modeling are simulations of material properties like strength and forming properties and for the specific microstructure evolution during processing (rolling, extrusion, annealing) under the influence of material constitution and process variations through the production process down to the final application. Examples are discussed for the through-process simulation of microstructures and related properties of Aluminium sheet, including DC ingot casting, pre-heating and homogenization, hot and cold rolling, final annealing. New results are included of simulation solution annealing and age hardening of 6xxx alloys for automotive applications. Physically based quantitative descriptions and computer assisted evaluation methods are new ICME methods of integrating new simulation tools also for customer applications, like heat affected zones in welding of age hardening alloys. The aspects of estimating the effect of specific elements due to growing recycling volumes requested also for high end Aluminium products are also discussed, being of special interest in the Aluminium producing industries.
Automated planning of computer assisted mosaic arthroplasty.
Inoue, Jiro; Kunz, Manuela; Hurtig, Mark B; Waldman, Stephen D; Stewart, A James
2011-01-01
We describe and evaluate a computer algorithm that automatically develops a surgical plan for computer assisted mosaic arthroplasty, a technically demanding procedure in which a set of osteochondral plugs are transplanted from a non-load-bearing area of the joint to the site of a cartilage defect. We found that the algorithm produced plans that were at least as good as a human expert, had less variability, and took less time.
Development of a computer-assisted learning software package on dental traumatology.
Tolidis, K; Crawford, P; Stephens, C; Papadogiannis, Y; Plakias, C
1998-10-01
The development of computer-assisted learning software packages is a relatively new field of computer application. The progress made in personal computer technology toward more user-friendly operating systems has stimulated the academic community to develop computer-assisted learning for pre- and postgraduate students. The ability of computers to combine audio and visual data in an interactive form provides a powerful educational tool. The purpose of this study was to develop and evaluate a computer-assisted learning package on dental traumatology. This program contains background information on the diagnosis, classification, and management of dental injuries in both the permanent and the deciduous dentitions. It is structured into chapters according to the nature of the injury and whether injury has occurred in the primary or permanent dentition. At the end of each chapter there is a self-assessment questionnaire as well as references to relevant literature. Extensive use of pictures and video provides a comprehensive overview of the subject.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laevastu, T.
1983-01-01
The effects of fishing on a given species biomass have been quantitatively evaluated. A constant recruitment is assumed in this study, but the evaluation can be computed on any known age distribution of exploitable biomass. Fishing mortality is assumed to be constant with age; however, spawning stress mortality increases with age. When fishing (mortality) increases, the spawning stress mortality decreases relative to total and exploitable biomasses. These changes are quantitatively shown for two species from the Bering Sea - walleye pollock, Theragra chalcogramma, and yellowfin sole, Limanda aspera.
Sánchez Gómez, Serafín; Ostos, Elisa María Cabot; Solano, Juan Manuel Maza; Salado, Tomás Francisco Herrero
2013-05-06
We evaluated a newly designed electronic portfolio (e-Portfolio) that provided quantitative evaluation of surgical skills. Medical students at the University of Seville used the e-Portfolio on a voluntary basis for evaluation of their performance in undergraduate surgical subjects. Our new web-based e-Portfolio was designed to evaluate surgical practical knowledge and skills targets. Students recorded each activity on a form, attached evidence, and added their reflections. Students self-assessed their practical knowledge using qualitative criteria (yes/no), and graded their skills according to complexity (basic/advanced) and participation (observer/assistant/independent). A numerical value was assigned to each activity, and the values of all activities were summated to obtain the total score. The application automatically displayed quantitative feedback. We performed qualitative evaluation of the perceived usefulness of the e-Portfolio and quantitative evaluation of the targets achieved. Thirty-seven of 112 students (33%) used the e-Portfolio, of which 87% reported that they understood the methodology of the portfolio. All students reported an improved understanding of their learning objectives resulting from the numerical visualization of progress, all students reported that the quantitative feedback encouraged their learning, and 79% of students felt that their teachers were more available because they were using the e-Portfolio. Only 51.3% of students reported that the reflective aspects of learning were useful. Individual students achieved a maximum of 65% of the total targets and 87% of the skills targets. The mean total score was 345 ± 38 points. For basic skills, 92% of students achieved the maximum score for participation as an independent operator, and all achieved the maximum scores for participation as an observer and assistant. For complex skills, 62% of students achieved the maximum score for participation as an independent operator, and 98% achieved the maximum scores for participation as an observer or assistant. Medical students reported that use of an electronic portfolio that provided quantitative feedback on their progress was useful when the number and complexity of targets were appropriate, but not when the portfolio offered only formative evaluations based on reflection. Students felt that use of the e-Portfolio guided their learning process by indicating knowledge gaps to themselves and teachers.
NASA Astrophysics Data System (ADS)
Wei, Jun; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella
2015-03-01
We are developing a computer-aided detection system to assist radiologists in detection of non-calcified plaques (NCPs) in coronary CT angiograms (cCTA). In this study, we performed quantitative analysis of arterial flow properties in each vessel branch and extracted flow information to differentiate the presence and absence of stenosis in a vessel segment. Under rest conditions, blood flow in a single vessel branch was assumed to follow Poiseuille's law. For a uniform pressure distribution, two quantitative flow features, the normalized arterial compliance per unit length (Cu) and the normalized volumetric flow (Q) along the vessel centerline, were calculated based on the parabolic Poiseuille solution. The flow features were evaluated for a two-class classification task to differentiate NCP candidates obtained by prescreening as true NCPs and false positives (FPs) in cCTA. For evaluation, a data set of 83 cCTA scans was retrospectively collected from 83 patient files with IRB approval. A total of 118 NCPs were identified by experienced cardiothoracic radiologists. The correlation between the two flow features was 0.32. The discriminatory ability of the flow features evaluated as the area under the ROC curve (AUC) was 0.65 for Cu and 0.63 for Q in comparison with AUCs of 0.56-0.69 from our previous luminal features. With stepwise LDA feature selection, volumetric flow (Q) was selected in addition to three other luminal features. With FROC analysis, the test results indicated a reduction of the FP rates to 3.14, 1.98, and 1.32 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. The study indicated that quantitative blood flow analysis has the potential to provide useful features for the detection of NCPs in cCTA.
Taherian, Sarvnaz; Selitskiy, Dmitry; Pau, James; Claire Davies, T
2017-02-01
Using a commercial electroencephalography (EEG)-based brain-computer interface (BCI), the training and testing protocol for six individuals with spastic quadriplegic cerebral palsy (GMFCS and MACS IV and V) was evaluated. A customised, gamified training paradigm was employed. Over three weeks, the participants spent two sessions exploring the system, and up to six sessions playing the game which focussed on EEG feedback of left and right arm motor imagery. The participants showed variable inconclusive results in the ability to produce two distinct EEG patterns. Participant performance was influenced by physical illness, motivation, fatigue and concentration. The results from this case study highlight the infancy of BCIs as a form of assistive technology for people with cerebral palsy. Existing commercial BCIs are not designed according to the needs of end-users. Implications for Rehabilitation Mood, fatigue, physical illness and motivation influence the usability of a brain-computer interface. Commercial brain-computer interfaces are not designed for practical assistive technology use for people with cerebral palsy. Practical brain-computer interface assistive technologies may need to be flexible to suit individual needs.
ERIC Educational Resources Information Center
Barrett, Andrew J.; And Others
The Center for Interactive Technology, Applications, and Research at the College of Engineering of the University of South Florida (Tampa) has developed objective and descriptive evaluation models to assist in determining the educational potential of computer and video courseware. The computer-based courseware evaluation model and the video-based…
Goshima, Yoshio; Hida, Tomonobu; Gotoh, Toshiyuki
2012-01-01
Axonal transport plays a crucial role in neuronal morphogenesis, survival and function. Despite its importance, however, the molecular mechanisms of axonal transport remain mostly unknown because a simple and quantitative assay system for monitoring this cellular process has been lacking. In order to better characterize the mechanisms involved in axonal transport, we formulate a novel computer-assisted monitoring system of axonal transport. Potential uses of this system and implications for future studies will be discussed.
Reduction of bias and variance for evaluation of computer-aided diagnostic schemes.
Li, Qiang; Doi, Kunio
2006-04-01
Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave-one-out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave-one-out and cross-validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave-one-out and cross-validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave-one-out and cross-validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.
Strategies for Using Peer-Assisted Learning Effectively in an Undergraduate Bioinformatics Course
ERIC Educational Resources Information Center
Shapiro, Casey; Ayon, Carlos; Moberg-Parker, Jordan; Levis-Fitzgerald, Marc; Sanders, Erin R.
2013-01-01
This study used a mixed methods approach to evaluate hybrid peer-assisted learning approaches incorporated into a bioinformatics tutorial for a genome annotation research project. Quantitative and qualitative data were collected from undergraduates who enrolled in a research-based laboratory course during two different academic terms at UCLA.…
Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario
2016-01-01
Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.
Biomechanical Evaluation of an Electric Power-Assisted Bicycle by a Musculoskeletal Model
NASA Astrophysics Data System (ADS)
Takehara, Shoichiro; Murakami, Musashi; Hase, Kazunori
In this study, we construct an evaluation system for the muscular activity of the lower limbs when a human pedals an electric power-assisted bicycle. The evaluation system is composed of an electric power-assisted bicycle, a numerical simulator and a motion capture system. The electric power-assisted bicycle in this study has a pedal with an attached force sensor. The numerical simulator for pedaling motion is a musculoskeletal model of a human. The motion capture system measures the joint angles of the lower limb. We examine the influence of the electric power-assisted force on each muscle of the human trunk and legs. First, an experiment of pedaling motion is performed. Then, the musculoskeletal model is calculated by using the experimental data. We discuss the influence on each muscle by electric power-assist. It is found that the muscular activity is decreased by the electric power-assist bicycle, and the reduction of the muscular force required for pedaling motion was quantitatively shown for every muscle.
Stocker, Elena; Toschkoff, Gregor; Sacher, Stephan; Khinast, Johannes G
2014-11-20
The purpose of this study is to evaluate the use of computer simulations for generating quantitative knowledge as a basis for risk ranking and mechanistic process understanding, as required by ICH Q9 on quality risk management systems. In this specific publication, the main focus is the demonstration of a risk assessment workflow, including a computer simulation for the generation of mechanistic understanding of active tablet coating in a pan coater. Process parameter screening studies are statistically planned under consideration of impacts on a potentially critical quality attribute, i.e., coating mass uniformity. Based on computer simulation data the process failure mode and effects analysis of the risk factors is performed. This results in a quantitative criticality assessment of process parameters and the risk priority evaluation of failure modes. The factor for a quantitative reassessment of the criticality and risk priority is the coefficient of variation, which represents the coating mass uniformity. The major conclusion drawn from this work is a successful demonstration of the integration of computer simulation in the risk management workflow leading to an objective and quantitative risk assessment. Copyright © 2014. Published by Elsevier B.V.
Qualitative and quantitative interpretation of SEM image using digital image processing.
Saladra, Dawid; Kopernik, Magdalena
2016-10-01
The aim of the this study is improvement of qualitative and quantitative analysis of scanning electron microscope micrographs by development of computer program, which enables automatic crack analysis of scanning electron microscopy (SEM) micrographs. Micromechanical tests of pneumatic ventricular assist devices result in a large number of micrographs. Therefore, the analysis must be automatic. Tests for athrombogenic titanium nitride/gold coatings deposited on polymeric substrates (Bionate II) are performed. These tests include microshear, microtension and fatigue analysis. Anisotropic surface defects observed in the SEM micrographs require support for qualitative and quantitative interpretation. Improvement of qualitative analysis of scanning electron microscope images was achieved by a set of computational tools that includes binarization, simplified expanding, expanding, simple image statistic thresholding, the filters Laplacian 1, and Laplacian 2, Otsu and reverse binarization. Several modifications of the known image processing techniques and combinations of the selected image processing techniques were applied. The introduced quantitative analysis of digital scanning electron microscope images enables computation of stereological parameters such as area, crack angle, crack length, and total crack length per unit area. This study also compares the functionality of the developed computer program of digital image processing with existing applications. The described pre- and postprocessing may be helpful in scanning electron microscopy and transmission electron microscopy surface investigations. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.
Pedicle screw placement using image guided techniques.
Merloz, P; Tonetti, J; Pittet, L; Coulomb, M; Lavalleé, S; Sautot, P
1998-09-01
Clinical evaluation of a computer assisted spine surgical system is presented. Eighty pedicle screws were inserted using computer assisted technology in thoracic and lumbar vertebrae for treatment of different types of disorders including fractures, spondylolisthesis, and scoliosis. Fifty-two patients with severe fractures, spondylolisthesis, or pseudoarthrosis of T10 to L5 were treated using a computer assisted technique on 1/2 the patients and performing the screw insertion manually for the other 1/2. At the same time, 28 pedicle screws were inserted in T12 to L4 vertebrae for scoliosis with the help of the computer assisted technique. Surgery was followed in all cases (66 vertebrae; 132 pedicle screws) by postoperative radiographs and computed tomographic examination, on which measurements of screw position relative to pedicle position could be done. For fractures, spondylolisthesis, or pseudarthrosis, comparison between the two groups showed that four screws in 52 (8%) vertebrae had incorrect placement with computer assisted technique whereas 22 screws in 52 (42%) vertebrae had incorrect placement with manual insertion. In patients with scoliosis, four screws in 28 (14%) vertebrae had incorrect placement. In all of the patients (132 pedicle screws) there were no neurologic complications. These results show that a computer assisted technique is much more accurate and safe than manual insertion.
An Adaptive Evaluation Structure for Computer-Based Instruction.
ERIC Educational Resources Information Center
Welsh, William A.
Adaptive Evaluation Structure (AES) is a set of linked computer programs designed to increase the effectiveness of interactive computer-assisted instruction at the college level. The package has four major features, the first of which is based on a prior cognitive inventory and on the accuracy and pace of student responses. AES adjusts materials…
A Formative and Summative Evaluation of Computer Integrated Instruction.
ERIC Educational Resources Information Center
Signer, Barbara
The purpose of this study was to conduct formative and summative evaluation for Computer Integrated Instruction (CII), an alternative use of computer-assisted instruction (CAI). The non-equivalent control group, pretest-posttest design was implemented with the class as the unit of analysis. Several of the instruments were adopted from existing CAI…
Witches, History, and Microcomputers: A Computer-Assisted Course on the Salem Witch Trials.
ERIC Educational Resources Information Center
Latner, Richard B.
1988-01-01
Describes the addition of a microcomputer component to a Tulane University (Louisiana) undergraduate history course on the Salem witchcraft trials. Discusses the use of a statistical package and a data set to analyze and display data and the enhancement of the active learning approach by introducing students to quantitative methods of historical…
The Relationship between Time in Computer-Assisted Instruction and the Increase in Reading Skills
ERIC Educational Resources Information Center
Shannon, Rene M.
2013-01-01
Educational leadership appropriates significant amounts of money for technology in school budgets. Teachers must decide how to use technology to maximize student learning and make the most efficient use of instructional minutes. The purpose of this quantitative correlational study was to determine if a relationship existed between the amount of…
ERIC Educational Resources Information Center
Gardenhire, Alissa; Diamond, John; Headlam, Camielle; Weiss, Michael J.
2016-01-01
Community colleges nationwide are looking for solutions to help students complete developmental (remedial) math--a known barrier to graduation. Some are offering computer-assisted, modular developmental math courses that allow students to earn credits incrementally and move through the curriculum at their own pace. One of these modularized…
Evaluation of the Computer Assisted Instruction Title I Project, 1980-81.
ERIC Educational Resources Information Center
Metrics Associates, Inc., Chelmsford, MA.
For the third year, six Massachusetts communities incorporated computer assisted instruction (CAI) into their regular Title I programs, for students in grades 1 through 9. It was hoped that CAI would produce reading and mathematics gains over and above those which are characteristic of more conventional Title I instructional approaches. A pretest,…
DLI-IBM Joint Feasibility Study in Computer-Assisted Foreign Language Instruction. Final Report.
ERIC Educational Resources Information Center
Adams, Edward N.; Rosenbaum, Peter S.
This document is the final report on a study of the use of computer assisted instruction (CAI). The objective of the study was to evaluate the potential applicability and usefulness of CAI in the instructional environment of the Defense Language Institute (DLI). The operational phases of the study were implemented in the Russian Aural…
ERIC Educational Resources Information Center
Luo, Beate
2016-01-01
This study investigates a computer-assisted pronunciation training (CAPT) technique that combines oral reading with peer review to improve pronunciation of Taiwanese English major students. In addition to traditional in-class instruction, students were given a short passage every week along with a recording of the respective text, read by a native…
Computer-Assisted English Learning System Based on Free Conversation by Topic
ERIC Educational Resources Information Center
Choi, Sung-Kwon; Kwon, Oh-Woog; Kim, Young-Kil
2017-01-01
This paper aims to describe a computer-assisted English learning system using chatbots and dialogue systems, which allow free conversation outside the topic without limiting the learner's flow of conversation. The evaluation was conducted by 20 experimenters. The performance of the system based on a free conversation by topic was measured by the…
ERIC Educational Resources Information Center
Prokhorov, Alexander V.; Fouladi, Rachel T.; de Moor, Carl; Warneke, Carla L.; Luca, Mario; Jones, Mary Mullin; Rosenblum, Carol; Emmons, Karen M.; Hudmon, Karen Suchanek; Yost, Tracey E.; Gritz, Ellen R.
2007-01-01
This report presents the experimental approach and baseline findings from "Look at Your Health," an ongoing study to develop and evaluate a computer-assisted, counselor-delivered smoking cessation program for community college students. It describes the expert system software program used for data collection and for provision of tailored feedback,…
ERIC Educational Resources Information Center
Lonigan, Christopher J.; Driscoll, Kimberly; Phillips, Beth M.; Cantor, Brenlee G.; Anthony, Jason L.; Goldstein, Howard
2003-01-01
A study evaluated the use of computer-assisted instruction (CAI) to provide training in phonological sensitivity skills to 45 preschool children at-risk for reading problems. Children exposed to CAI made significantly greater gains on rhyming and elision skills compared to controls. Expressive vocabulary scores were predictive of pre- to posttest…
Models and techniques for evaluating the effectiveness of aircraft computing systems
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1978-01-01
The development of system models that can provide a basis for the formulation and evaluation of aircraft computer system effectiveness, the formulation of quantitative measures of system effectiveness, and the development of analytic and simulation techniques for evaluating the effectiveness of a proposed or existing aircraft computer are described. Specific topics covered include: system models; performability evaluation; capability and functional dependence; computation of trajectory set probabilities; and hierarchical modeling of an air transport mission.
[Computer-assisted phonetography as a diagnostic aid in functional dysphonia].
Airainer, R; Klingholz, F
1991-07-01
A total of 160 voice-trained and untrained subjects with functional dysphonia were given a "clinical rating" according to their clinical findings. This was a certain value on a scale that recorded the degree of functional voice disorder ranging from a marked hypofunction to an extreme hyperfunction. The phonetograms of these patients were approximated by ellipses, whereby the definition and quantitative recording of several phonetogram parameters were rendered possible. By means of a linear combination of phonetogram parameters, a "calculated assessment" was obtained for each patient that was expected to tally with the "clinical rating". This paper demonstrates that a graduation of the dysphonic clinical picture with regard to the presence of hypofunctional or hyperfunctional components is possible via computerised phonetogram evaluation. In this case, the "calculated assessments" for both male and female singers and non-singers must be computed using different linear combinations. The method can be introduced as a supplementary diagnostic procedure in the diagnosis of functional dysphonia.
Preparing for Computer Use. Revised.
ERIC Educational Resources Information Center
South Carolina State Dept. of Education, Columbia.
Intended to assist school districts in designing high school credit courses, preparing staff development activities related to computer utilization, and selecting and evaluating instructional software, this document offers outlines for the following student courses: (1) Introduction to Computers, a computer literacy course covering computer…
[Contribution of X-ray computed tomography in the evaluation of kidney performance].
Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent
2012-07-01
X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Reich, Sven; Fischer, Sören; Sobotta, Bernhard; Klapper, Horst-Uwe; Gozdowski, Stephan
2010-01-01
The purpose of this preliminary study was to evaluate the clinical performance of chairside-generated crowns over a preliminary time period of 24 months. Forty-one posterior crowns made of a machinable lithium disilicate ceramic for full-contour crowns were inserted in 34 patients using a chairside computer-aided design/computer-assisted manufacturing technique. The crowns were evaluated at baseline and after 6, 12, and 24 months according to modified United States Public Health Service criteria. After 2 years, all reexamined crowns (n = 39) were in situ; one abutment exhibited secondary caries and two abutments received root canal treatment. Within the limited observation period, the crowns revealed clinically satisfying results.
1980-06-01
courseware package on how to program lessons for an automated system. Since PLANIT (Programming Language for Interactive Teaching) is the student/author...assisted instruction (CAI), how to program PLANIT lessons, and to evaluate the effectiveness of the package for select Army users. The resultant courseware
7 CFR 1944.419 - Final grantee evaluation.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) PROGRAM REGULATIONS (CONTINUED) HOUSING Self-Help Technical Assistance Grants § 1944.419 Final grantee... Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS..., application, this regulation, and any amendments. (a) This is a quantitative evaluation of the grantee to...
An Evaluation of Micro PLATO Fortran 77 Instruction.
ERIC Educational Resources Information Center
Funk, Kenneth; And Others
1986-01-01
Evaluated the use of computer assisted instruction in teaching Fortran 77 in the College of Engineering at Oregon State University. Also investigated the effect of such factors as mathematics and computer programming background on student performance in an introductory programming course sequence. (JN)
ERIC Educational Resources Information Center
Boody, Charles G., Ed.
1986-01-01
Six articles on music and computing address development of computer-based music technology, computer assisted instruction (CAI) in ear training and music fundamentals, a machine-independent data structure for musical pitch relationship representation, touch tablet input device in a melodic dictation CAI game, and systematic evaluation strategies…
Development and Evaluation of Computer-Based Laboratory Practical Learning Tool
ERIC Educational Resources Information Center
Gandole, Y. B.
2006-01-01
Effective evaluation of educational software is a key issue for successful introduction of advanced tools in the curriculum. This paper details to developing and evaluating a tool for computer assisted learning of science laboratory courses. The process was based on the generic instructional system design model. Various categories of educational…
Using Text-to-Speech (TTS) for Audio Computer-Assisted Self-Interviewing (ACASI)
ERIC Educational Resources Information Center
Couper, Mick P.; Berglund, Patricia; Kirgis, Nicole; Buageila, Sarrah
2016-01-01
We evaluate the use of text-to-speech (TTS) technology for audio computer-assisted self-interviewing (ACASI). We use a quasi-experimental design, comparing the use of recorded human voice in the 2006-2010 National Survey of Family Growth with the use of TTS in the first year of the 2011-2013 survey, where the essential survey conditions are…
ERIC Educational Resources Information Center
Adrian, Jose A.; Gonzalez, Mercedes; Buiza, Juan J.; Sage, Karen
2011-01-01
Purpose: To extend the use of the Spanish Computer-assisted Anomia Rehabilitation Program (CARP-2) for anomia from a single case to a group of 15 people with aphasia. To evaluate whether the treatment is active (Phase 1) for this group (Robey & Schultz, 1998), providing potential explanations as to why. Methods: Fifteen participants with chronic…
ERIC Educational Resources Information Center
Zaranis, Nicholas; Synodi, Evanthia
2017-01-01
The purpose of this study is to compare and evaluate the effectiveness of computer assisted teaching of geometry shapes and an interactionist approach to teaching geometry in kindergarten versus other more traditional teaching methods. Our research compares the improvement of the children's geometrical competence using two teaching approaches. The…
ERIC Educational Resources Information Center
Mitzel, Harold E.
In cooperation with the United States Navy, this project was undertaken to examine the feasibility of computer assisted instruction in clinical malaria recognition, to train a small group of Naval personnel in techniques of creating and presenting such material, and to evaluate the course by giving it to a representative sample of Naval medical…
Simulating Drosophila Genetics with the Computer.
ERIC Educational Resources Information Center
Small, James W., Jr.; Edwards, Kathryn L.
1979-01-01
Presents some techniques developed to help improve student understanding of Mendelian principles through the use of a computer simulation model by the genetic system of the fruit fly. Includes discussion and evaluation of this computer assisted program. (MA)
How To Design a Program Evaluation. CSE Program Evaluation Kit, Volume 3. Second Edition.
ERIC Educational Resources Information Center
Fitz-Gibbon, Carol Taylor; Morris, Lynn Lyons
The "CSE Program Evaluation Kit" is a series of nine books intended to assist people conducting program evaluations. This volume, the third in the kit, discusses the logic underlying the use of quantitative research designs, including the pretest-posttest design, and supplies step-by-step procedures for setting up and interpreting the…
The Development of MUMPS-Based Rehabilitation Psychology Computer Applications.
ERIC Educational Resources Information Center
Dutro, Kenneth R.
The use of computer assisted programs in career exploration and occupational information is well documented. Various phases of the vocational counseling process, i.e., diagnostic evaluation, program planning, career exploration, case management, and program evaluation, offer similarly promising opportunities for computerization. Using the…
Qayumi, A K; Kurihara, Y; Imai, M; Pachev, G; Seo, H; Hoshino, Y; Cheifetz, R; Matsuura, K; Momoi, M; Saleem, M; Lara-Guerra, H; Miki, Y; Kariya, Y
2004-10-01
This study aimed to compare the effects of computer-assisted, text-based and computer-and-text learning conditions on the performances of 3 groups of medical students in the pre-clinical years of their programme, taking into account their academic achievement to date. A fourth group of students served as a control (no-study) group. Participants were recruited from the pre-clinical years of the training programmes in 2 medical schools in Japan, Jichi Medical School near Tokyo and Kochi Medical School near Osaka. Participants were randomly assigned to 4 learning conditions and tested before and after the study on their knowledge of and skill in performing an abdominal examination, in a multiple-choice test and an objective structured clinical examination (OSCE), respectively. Information about performance in the programme was collected from school records and students were classified as average, good or excellent. Student and faculty evaluations of their experience in the study were explored by means of a short evaluation survey. Compared to the control group, all 3 study groups exhibited significant gains in performance on knowledge and performance measures. For the knowledge measure, the gains of the computer-assisted and computer-assisted plus text-based learning groups were significantly greater than the gains of the text-based learning group. The performances of the 3 groups did not differ on the OSCE measure. Analyses of gains by performance level revealed that high achieving students' learning was independent of study method. Lower achieving students performed better after using computer-based learning methods. The results suggest that computer-assisted learning methods will be of greater help to students who do not find the traditional methods effective. Explorations of the factors behind this are a matter for future research.
Feasibility of a computer-assisted feedback system between dispatch centre and ambulances.
Lindström, Veronica; Karlsten, Rolf; Falk, Ann-Charlotte; Castrèn, Maaret
2011-06-01
The aim of the study was to evaluate the feasibility of a newly developed computer-assisted feedback system between dispatch centre and ambulances in Stockholm, Sweden. A computer-assisted feedback system based on a Finnish model was designed to fit the Swedish emergency medical system. Feedback codes were identified and divided into three categories; assessment of patients' primary condition when ambulance arrives at scene, no transport by the ambulance and level of priority. Two ambulances and one emergency medical communication centre (EMCC) in Stockholm participated in the study. A sample of 530 feedback codes sent through the computer-assisted feedback system was reviewed. The information on the ambulance medical records was compared with the feedback codes used and 240 assignments were further analyzed. The used feedback codes sent from ambulance to EMCC were correct in 92% of the assignments. The most commonly used feedback code sent to the emergency medical dispatchers was 'agree with the dispatchers' assessment'. In addition, in 160 assignments there was a mismatch between emergency medical dispatchers and ambulance nurse assessments. Our results have shown a high agreement between medical dispatchers and ambulance nurse assessment. The feasibility of the feedback codes seems to be acceptable based on the small margin of error. The computer-assisted feedback system may, when used on a daily basis, make it possible for the medical dispatchers to receive feedback in a structural way. The EMCC organization can directly evaluate any changes in the assessment protocol by structured feedback sent from the ambulance.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki
2009-02-01
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
A contextual data mining approach toward assisting the treatment of anxiety disorders.
Panagiotakopoulos, Theodor Chris; Lyras, Dimitrios Panagiotis; Livaditis, Miltos; Sgarbas, Kyriakos N; Anastassopoulos, George C; Lymberopoulos, Dimitrios K
2010-05-01
Anxiety disorders are considered the most prevalent of mental disorders. Nevertheless, the exact reasons that provoke them to patients remain yet not clearly specified, while the literature concerning the environment for monitoring and treatment support is rather scarce warranting further investigation. Toward this direction, in this study a context-aware approach is proposed, aiming to provide medical supervisors with a series of applications and personalized services targeted to exploit the multiparameter contextual data collected through a long-term monitoring procedure. More specifically, an application that assists the archiving and retrieving of the patients' health records was developed, and four treatment supportive services were considered. The three of them focus on the discovery of possible associations between the patient's contextual data; the last service aims at predicting the stress level a patient might suffer from, in a given context. The proposed approach was experimentally evaluated quantitatively (in terms of computational efficiency and time requirements) and qualitatively by experts on the field of mental health domain. The feedback received was very encouraging and the proposed approach seems quite useful to the anxiety disorders' treatment.
Susarla, Srinivas M; Dodson, Thomas B; Lopez, Joseph; Swanson, Edward W; Calotta, Nicholas; Peacock, Zachary S
2015-08-01
Academic promotion is linked to research productivity. The purpose of this study was to assess the correlation between quantitative measures of academic productivity and academic rank among academic oral and maxillofacial surgeons. This was a cross-sectional study of full-time academic oral and maxillofacial surgeons in the United States. The predictor variables were categorized as demographic (gender, medical degree, research doctorate, other advanced degree) and quantitative measures of academic productivity (total number of publications, total number of citations, maximum number of citations for a single article, I-10 index [number of publications with ≥ 10 citations], and h-index [number of publications h with ≥ h citations each]). The outcome variable was current academic rank (instructor, assistant professor, associate professor, professor, or endowed professor). Descriptive, bivariate, and multiple regression statistics were computed to evaluate associations between the predictors and academic rank. Receiver-operator characteristic curves were computed to identify thresholds for academic promotion. The sample consisted of 324 academic oral and maxillofacial surgeons, of whom 11.7% were female, 40% had medical degrees, and 8% had research doctorates. The h-index was the most strongly correlated with academic rank (ρ = 0.62, p < 0.001). H-indexes of ≥ 4, ≥ 8, and ≥ 13 were identified as thresholds for promotion to associate professor, professor, and endowed professor, respectively (p < 0.001). This study found that the h-index was strongly correlated with academic rank among oral and maxillofacial surgery faculty members and thus suggests that promotions committees should consider using the h-index as an additional method to assess research activity.
An Evaluation of Computer-Aided Instruction in an Introductory Biostatistics Course.
ERIC Educational Resources Information Center
Forsythe, Alan B.; Freed, James R.
1979-01-01
Evaluates the effectiveness of computer assisted instruction for teaching biostatistics to first year students at the UCLA School of Dentistry. Results do not demonstrate the superiority of CAI but do suggest that CAI compares favorably to conventional lecture and programed instruction methods. (RAO)
Methodology for characterizing potential adversaries of Nuclear Material Safeguards Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirkwood, C.W.; Pollock, S.M.
1978-11-01
The results are described of a study by Woodward--Clyde Consultants to assist the University of California Lawrence Livermore Laboratory in the development of methods to analyze and evaluate Nuclear Material Safeguards (NMS) Systems. The study concentrated on developing a methodology to assist experts in describing, in quantitative form, their judgments about the characteristics of potential adversaries of NMS Systems.
ERIC Educational Resources Information Center
Streibel, Michael J.; Garhart, Casey
1985-01-01
Describes the approach taken in an education computing course for pre- and in-service teachers. Outlines the basic operational, analytical, and evaluation skills that are emphasized in the course, suggesting that these skills go beyond the attainment of computer literacy and can assist in the effective use of computers. (ML)
Phan, Philippe; Mezghani, Neila; Aubin, Carl-Éric; de Guise, Jacques A; Labelle, Hubert
2011-07-01
Adolescent idiopathic scoliosis (AIS) is a complex spinal deformity whose assessment and treatment present many challenges. Computer applications have been developed to assist clinicians. A literature review on computer applications used in AIS evaluation and treatment has been undertaken. The algorithms used, their accuracy and clinical usability were analyzed. Computer applications have been used to create new classifications for AIS based on 2D and 3D features, assess scoliosis severity or risk of progression and assist bracing and surgical treatment. It was found that classification accuracy could be improved using computer algorithms that AIS patient follow-up and screening could be done using surface topography thereby limiting radiation and that bracing and surgical treatment could be optimized using simulations. Yet few computer applications are routinely used in clinics. With the development of 3D imaging and databases, huge amounts of clinical and geometrical data need to be taken into consideration when researching and managing AIS. Computer applications based on advanced algorithms will be able to handle tasks that could otherwise not be done which can possibly improve AIS patients' management. Clinically oriented applications and evidence that they can improve current care will be required for their integration in the clinical setting.
1980-03-01
authoring system which would provide a basis for the cost effective production of computer-assisted irstruction (CAI) materials, It addresses the definition...RESULTS- - ------------------- 58 CAI Materials Development Times - - - 5J CAI Module Instructional Effectiveness -------- -- 59 First-Pass Module...CONCLUSIONS AND RECOMMENDATIONS ------ --- -- -- 70 Effectiveness of the Authoring System and Suggestions for Further Development - ----- --- -- --- 70
Kim, Jeong Rye; Shim, Woo Hyun; Yoon, Hee Mang; Hong, Sang Hyup; Lee, Jin Seong; Cho, Young Ah; Kim, Sangki
2017-12-01
The purpose of this study is to evaluate the accuracy and efficiency of a new automatic software system for bone age assessment and to validate its feasibility in clinical practice. A Greulich-Pyle method-based deep-learning technique was used to develop the automatic software system for bone age determination. Using this software, bone age was estimated from left-hand radiographs of 200 patients (3-17 years old) using first-rank bone age (software only), computer-assisted bone age (two radiologists with software assistance), and Greulich-Pyle atlas-assisted bone age (two radiologists with Greulich-Pyle atlas assistance only). The reference bone age was determined by the consensus of two experienced radiologists. First-rank bone ages determined by the automatic software system showed a 69.5% concordance rate and significant correlations with the reference bone age (r = 0.992; p < 0.001). Concordance rates increased with the use of the automatic software system for both reviewer 1 (63.0% for Greulich-Pyle atlas-assisted bone age vs 72.5% for computer-assisted bone age) and reviewer 2 (49.5% for Greulich-Pyle atlas-assisted bone age vs 57.5% for computer-assisted bone age). Reading times were reduced by 18.0% and 40.0% for reviewers 1 and 2, respectively. Automatic software system showed reliably accurate bone age estimations and appeared to enhance efficiency by reducing reading times without compromising the diagnostic accuracy.
Sihong Chen; Jing Qin; Xing Ji; Baiying Lei; Tianfu Wang; Dong Ni; Jie-Zhi Cheng
2017-03-01
The gap between the computational and semantic features is the one of major factors that bottlenecks the computer-aided diagnosis (CAD) performance from clinical usage. To bridge this gap, we exploit three multi-task learning (MTL) schemes to leverage heterogeneous computational features derived from deep learning models of stacked denoising autoencoder (SDAE) and convolutional neural network (CNN), as well as hand-crafted Haar-like and HoG features, for the description of 9 semantic features for lung nodules in CT images. We regard that there may exist relations among the semantic features of "spiculation", "texture", "margin", etc., that can be explored with the MTL. The Lung Image Database Consortium (LIDC) data is adopted in this study for the rich annotation resources. The LIDC nodules were quantitatively scored w.r.t. 9 semantic features from 12 radiologists of several institutes in U.S.A. By treating each semantic feature as an individual task, the MTL schemes select and map the heterogeneous computational features toward the radiologists' ratings with cross validation evaluation schemes on the randomly selected 2400 nodules from the LIDC dataset. The experimental results suggest that the predicted semantic scores from the three MTL schemes are closer to the radiologists' ratings than the scores from single-task LASSO and elastic net regression methods. The proposed semantic attribute scoring scheme may provide richer quantitative assessments of nodules for better support of diagnostic decision and management. Meanwhile, the capability of the automatic association of medical image contents with the clinical semantic terms by our method may also assist the development of medical search engine.
NASA Technical Reports Server (NTRS)
D'Amelio, F.; Wu, L. C.; Fox, R. A.; Daunton, N. G.; Corcoran, M. L.; Polyakov, I.
1998-01-01
Quantitative evaluation of gamma-aminobutyric acid immunoreactivity (GABA-IR) in the hindlimb representation of the rat somatosensory cortex after 14 days of exposure to hypergravity (hyper-G) was conducted by using computer-assisted image processing. The area of GABA-IR axosomatic terminals apposed to pyramidal cells of cortical layer V was reduced in rats exposed to hyper-G compared with control rats, which were exposed either to rotation alone or to vivarium conditions. Based on previous immunocytochemical and behavioral studies, we suggest that this reduction is due to changes in sensory feedback information from muscle receptors. Consequently, priorities for muscle recruitment are altered at the cortical level, and a new pattern of muscle activity is thus generated. It is proposed that the reduction observed in GABA-IR of the terminal area around pyramidal neurons is the immunocytochemical expression of changes in the activity of GABAergic cells that participate in reprogramming motor outputs to achieve effective movement control in response to alterations in the afferent information.
Medical education as a science: the quality of evidence for computer-assisted instruction.
Letterie, Gerard S
2003-03-01
A marked increase in the number of computer programs for computer-assisted instruction in the medical sciences has occurred over the past 10 years. The quality of both the programs and the literature that describe these programs has varied considerably. The purposes of this study were to evaluate the published literature that described computer-assisted instruction in medical education and to assess the quality of evidence for its implementation, with particular emphasis on obstetrics and gynecology. Reports published between 1988 and 2000 on computer-assisted instruction in medical education were identified through a search of MEDLINE and Educational Resource Identification Center and a review of the bibliographies of the articles that were identified. Studies were selected if they included a description of computer-assisted instruction in medical education, regardless of the type of computer program. Data were extracted with a content analysis of 210 reports. The reports were categorized according to study design (comparative, prospective, descriptive, review, or editorial), type of computer-assisted instruction, medical specialty, and measures of effectiveness. Computer-assisted instruction programs included online technologies, CD-ROMs, video laser disks, multimedia work stations, virtual reality, and simulation testing. Studies were identified in all medical specialties, with a preponderance in internal medicine, general surgery, radiology, obstetrics and gynecology, pediatrics, and pathology. Ninety-six percent of the articles described a favorable impact of computer-assisted instruction in medical education, regardless of the quality of the evidence. Of the 210 reports that were identified, 60% were noncomparative, descriptive reports of new techniques in computer-assisted instruction, and 15% and 14% were reviews and editorials, respectively, of existing technology. Eleven percent of studies were comparative and included some form of assessment of the effectiveness of the computer program. These assessments included pre- and posttesting and questionnaires to score program quality, perceptions of the medical students and/or residents regarding the program, and impact on learning. In one half of these comparative studies, computer-assisted instruction was compared with traditional modes of teaching, such as text and lectures. Six studies compared performance before and after the computer-assisted instruction. Improvements were shown in 5 of the studies. In the remainder of the studies, computer-assisted instruction appeared to result in similar test performance. Despite study design or outcome, most articles described enthusiastic endorsement of the programs by the participants, including medical students, residents, and practicing physicians. Only 1 study included cost analysis. Thirteen of the articles were in obstetrics and gynecology. Computer-assisted instruction has assumed to have an increasing role in medical education. In spite of enthusiastic endorsement and continued improvements in software, few studies of good design clearly demonstrate improvement in medical education over traditional modalities. There are no comparative studies in obstetrics and gynecology that demonstrate a clear-cut advantage. Future studies of computer-assisted instruction that include comparisons and cost assessments to gauge their effectiveness over traditional methods may better define their precise role.
Zheng, Xiujuan; Wei, Wentao; Huang, Qiu; Song, Shaoli; Wan, Jieqing; Huang, Gang
2017-01-01
The objective and quantitative analysis of longitudinal single photon emission computed tomography (SPECT) images are significant for the treatment monitoring of brain disorders. Therefore, a computer aided analysis (CAA) method is introduced to extract a change-rate map (CRM) as a parametric image for quantifying the changes of regional cerebral blood flow (rCBF) in longitudinal SPECT brain images. The performances of the CAA-CRM approach in treatment monitoring are evaluated by the computer simulations and clinical applications. The results of computer simulations show that the derived CRMs have high similarities with their ground truths when the lesion size is larger than system spatial resolution and the change rate is higher than 20%. In clinical applications, the CAA-CRM approach is used to assess the treatment of 50 patients with brain ischemia. The results demonstrate that CAA-CRM approach has a 93.4% accuracy of recovered region's localization. Moreover, the quantitative indexes of recovered regions derived from CRM are all significantly different among the groups and highly correlated with the experienced clinical diagnosis. In conclusion, the proposed CAA-CRM approach provides a convenient solution to generate a parametric image and derive the quantitative indexes from the longitudinal SPECT brain images for treatment monitoring.
Microwave assisted pyrolysis of halogenated plastics recovered from waste computers.
Rosi, Luca; Bartoli, Mattia; Frediani, Marco
2018-03-01
Microwave Assisted Pyrolysis (MAP) of the plastic fraction of Waste from Electric and Electronic Equipment (WEEE) from end-life computers was run with different absorbers and set-ups in a multimode batch reactor. A large amount of various different liquid fractions (up to 76.6wt%) were formed together with a remarkable reduction of the solid residue (up to 14.2wt%). The liquid fractions were characterized using the following different techniques: FT-IR ATR, 1 H NMR and a quantitative GC-MS analysis. The liquid fractions showed low density and viscosity, together with a high concentration of useful chemicals such as styrene (up to 117.7mg/mL), xylenes (up to 25.6mg/mL for p-xylene) whereas halogenated compounds were absent or present in a very low amounts. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bai, Xiao-ping; Zhang, Xi-wei
2013-01-01
Selecting construction schemes of the building engineering project is a complex multiobjective optimization decision process, in which many indexes need to be selected to find the optimum scheme. Aiming at this problem, this paper selects cost, progress, quality, and safety as the four first-order evaluation indexes, uses the quantitative method for the cost index, uses integrated qualitative and quantitative methodologies for progress, quality, and safety indexes, and integrates engineering economics, reliability theories, and information entropy theory to present a new evaluation method for building construction project. Combined with a practical case, this paper also presents detailed computing processes and steps, including selecting all order indexes, establishing the index matrix, computing score values of all order indexes, computing the synthesis score, sorting all selected schemes, and making analysis and decision. Presented method can offer valuable references for risk computing of building construction projects.
Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo
2017-03-01
Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs). The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated. Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05). The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001). CAD-CAM and overcasting methods present similar marginal fit and stress values for 3-unit FDP frameworks. The decreased marginal fit of frameworks induces greater stress in the implant-supported system. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Computer Assisted REhabilitation (CARE) Lab: A novel approach towards Pediatric Rehabilitation 2.0.
Olivieri, Ivana; Meriggi, Paolo; Fedeli, Cristina; Brazzoli, Elena; Castagna, Anna; Roidi, Marina Luisa Rodocanachi; Angelini, Lucia
2018-01-01
Pediatric Rehabilitation therapists have always worked using a variety of off-the-shelf or custom-made objects and devices, more recently including computer based systems. These Information and Communication Technology (ICT) solutions vary widely in complexity, from easy-to-use interactive videogame consoles originally intended for entertainment purposes to sophisticated systems specifically developed for rehabilitation.This paper describes the principles underlying an innovative "Pediatric Rehabilitation 2.0" approach, based on the combination of suitable ICT solutions and traditional rehabilitation, which has been progressively refined while building up and using a computer-assisted rehabilitation laboratory. These principles are thus summarized in the acronym EPIQ, to account for the terms Ecological, Personalized, Interactive and Quantitative. The paper also presents the laboratory, which has been designed to meet the children's rehabilitation needs and to empower therapists in their work. The laboratory is equipped with commercial hardware and specially developed software called VITAMIN: a virtual reality platform for motor and cognitive rehabilitation.
Computer-Assisted Learning in Elementary Reading: A Randomized Control Trial
ERIC Educational Resources Information Center
Shannon, Lisa Cassidy; Styers, Mary Koenig; Wilkerson, Stephanie Baird; Peery, Elizabeth
2015-01-01
This study evaluated the efficacy of Accelerated Reader, a computer-based learning program, at improving student reading. Accelerated Reader is a progress-monitoring, assessment, and practice tool that supports classroom instruction and guides independent reading. Researchers used a randomized controlled trial to evaluate the program with 344…
Education: AIChE Probes Impact of Computer on Future Engineering Education.
ERIC Educational Resources Information Center
Krieger, James
1983-01-01
Evaluates influence of computer assisted instruction on engineering education, considering use of computers to remove burden of doing calculations and to provide interactive self-study programs of a tutorial/remedial nature. Cites universities requiring personal computer purchase, pointing out possibility for individualized design assignments.…
A Comparative Evaluation of Computer Based and Non-Computer Based Instructional Strategies.
ERIC Educational Resources Information Center
Emerson, Ian
1988-01-01
Compares the computer assisted instruction (CAI) tutorial with its non-computerized pedagogical roots: the Socratic Dialog with Skinner's Programmed Instruction. Tests the effectiveness of a CAI tutorial on diffusion and osmosis against four other interactive and non-interactive instructional strategies. Notes computer based strategies were…
Evaluations of Technology-Assisted Small-Group Tutoring for Struggling Readers
ERIC Educational Resources Information Center
Madden, Nancy A.; Slavin, Robert E.
2017-01-01
This article reports on 2 experiments in inner-city Baltimore evaluating a computer-assisted tutoring approach, Tutoring With Alphie (TWA), in which 1 paraprofessional can work with up to 6 children at a time. In Study 1, we randomly assigned 14 schools to receive TWA or to continue with whatever approaches they were currently using. Each…
Use of microcomputers for self-assessment and continuing education in anaesthesia.
Schmulian, C; Kenny, G N; Campbell, D
1982-01-01
The suitability of computer-assisted self-assessment was evaluated as a means of quality assurance in anaesthesia. Altogether 202 anaesthetists participated in four trials of the method. Analyses of their performance in a self-assessment programme dealing with obstetric anaesthesia showed significant differences in the levels of knowledge of anaesthetists practising for different numbers of years. The acceptability of computer-assisted self-assessment ranged from 91% to 100% for the four trials. Similar programs have been shown to be of value in medical education and thus computer-assisted self-assessment appears to fulfil simultaneously the functions of self-assessment and continuing education. The criteria for a method of quality assurance are met. PMID:6800476
NASA Astrophysics Data System (ADS)
Mazingo, Diann Etsuko
Feedback has been identified as a key variable in developing academic self-efficacy. The types of feedback can vary from a traditional, objectivist approach that focuses on minimizing learner errors to a more constructivist approach, focusing on facilitating understanding. The influx of computer-based courses, whether online or through a series of computer-assisted instruction (CAI) modules require that the current research of effective feedback techniques in the classroom be extended to computer environments in order to impact their instructional design. In this study, exposure to different types of feedback during a chemistry CAI module was studied in relation to science self-efficacy (SSE) and performance on an objective-driven assessment (ODA) of the chemistry concepts covered in the unit. The quantitative analysis consisted of two separate ANCOVAs on the dependent variables, using pretest as the covariate and group as the fixed factor. No significant differences were found for either variable between the three groups on adjusted posttest means for the ODA and SSE measures (.95F(2, 106) = 1.311, p = 0.274 and .95F(2, 106) = 1.080, p = 0.344, respectively). However, a mixed methods approach yielded valuable qualitative insights into why only one overall quantitative effect was observed. These findings are discussed in relation to the need to further refine the instruments and methods used in order to more fully explore the possibility that type of feedback might play a role in developing SSE, and consequently, improve academic performance in science. Future research building on this study may reveal significance that could impact instructional design practices for developing online and computer-based instruction.
Kohlberger, P D; Obermair, A; Sliutz, G; Heinzl, H; Koelbl, H; Breitenecker, G; Gitsch, G; Kainz, C
1996-06-01
Microvessel density in the area of the most intense neovascularization in invasive breast carcinoma is reported to be an independent prognostic factor. The established method of enumeration of microvessel density is to count the vessels using an ocular raster (counted microvessel density [CMVD]). The vessels were detected by staining endothelial cells using Factor VIII-related antigen. The aim of the study was to compare the CMVD results with the percentage of factor VIII-related antigen-stained area using computer-assisted image analysis. A true color red-green-blue (RGB) image analyzer based on a morphologically reduced instruction set computer processor was used to evaluate the area of stained endothelial cells. Sixty invasive breast carcinomas were included in the analysis. There was no significant correlation between the CMVD and the percentage of factor VIII-related antigen-stained area (Spearman correlation coefficient = 0.24, confidence interval = 0.02-0.46). Although high CMVD was significantly correlated with poorer recurrence free survival (P = .024), percentage of factor VIII-related antigen-stained area showed no prognostic value. Counted microvessel density and percentage of factor VIII-related antigen-stained area showed a highly significant correlation with vessel invasion (P = .0001 and P = .02, respectively). There was no correlation between CMVD and percentage of factor VIII-related antigen-stained area with other prognostic factors. In contrast to the CMVD within malignant tissue, the percentage of factor VIII-related antigen-stained area is not suitable as an indicator of prognosis in breast cancer patients.
systems such as management information systems . To provide a methodology yielding quantitative results which may assist a commander and his staff in...this analysis, it is proposed that management information systems be evaluated as a whole by a technique defined as the semantic differential. Each
NASA Technical Reports Server (NTRS)
Hanley, G.
1979-01-01
Computer assisted design of a gallium arsenide solid state dc-to-RF converter with supportive fabrication data was investigated. Specific tasks performed include: computer program checkout; amplifier comparisons; computer design analysis of GaSa solar cells; and GaAs diode evaluation. Results obtained in the design and evaluation of transistors for the microwave space power system are presented.
Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.
Handels, H; Ehrhardt, J
2009-01-01
Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or operation planning is a complex interdisciplinary process. Image computing methods enable new insights into the patient's image data and have the future potential to improve medical diagnostics and patient treatment.
NASA Astrophysics Data System (ADS)
Chan, Harley; Gilbert, Ralph W.; Pagedar, Nitin A.; Daly, Michael J.; Irish, Jonathan C.; Siewerdsen, Jeffrey H.
2010-02-01
esthetic appearance is one of the most important factors for reconstructive surgery. The current practice of maxillary reconstruction chooses radial forearm, fibula or iliac rest osteocutaneous to recreate three-dimensional complex structures of the palate and maxilla. However, these bone flaps lack shape similarity to the palate and result in a less satisfactory esthetic. Considering similarity factors and vasculature advantages, reconstructive surgeons recently explored the use of scapular tip myo-osseous free flaps to restore the excised site. We have developed a new method that quantitatively evaluates the morphological similarity of the scapula tip bone and palate based on a diagnostic volumetric computed tomography (CT) image. This quantitative result was further interpreted as a color map that rendered on the surface of a three-dimensional computer model. For surgical planning, this color interpretation could potentially assist the surgeon to maximize the orientation of the bone flaps for best fit of the reconstruction site. With approval from the Research Ethics Board (REB) of the University Health Network, we conducted a retrospective analysis with CT image obtained from 10 patients. Each patient had a CT scans including the maxilla and chest on the same day. Based on this image set, we simulated total, subtotal and hemi palate reconstruction. The procedure of simulation included volume segmentation, conversing the segmented volume to a stereo lithography (STL) model, manual registration, computation of minimum geometric distances and curvature between STL model. Across the 10 patients data, we found the overall root-mean-square (RMS) conformance was 3.71+/- 0.16 mm
ERIC Educational Resources Information Center
Mac Iver, Douglas J.; Balfanz, Robert; Plank, Stephan B.
1999-01-01
Two studies evaluated the Computer- and Team-Assisted Mathematics Acceleration course (CATAMA) in Talent Development Middle Schools. The first study compared growth in math achievement for 96 seventh-graders (48 of whom participated in CATAMA and 48 of whom did not); the second study gathered data from interviews with, and observations of, CATAMA…
ERIC Educational Resources Information Center
Fasting, Rolf B.; Lyster, Solveig-Alma Halaas
2005-01-01
The aim of the present study is to evaluate the effect of MultiFunk, a computer program designed to assist reading, on the reading and spelling proficiency of struggling readers. Fifty-two below-average readers and spellers, in grades 5, 6 and 7, were randomly assigned as experimental and control groups (N = 26 + 26). In addition, 114 classmates,…
Program management model study
NASA Technical Reports Server (NTRS)
Connelly, J. J.; Russell, J. E.; Seline, J. R.; Sumner, N. R., Jr.
1972-01-01
Two models, a system performance model and a program assessment model, have been developed to assist NASA management in the evaluation of development alternatives for the Earth Observations Program. Two computer models were developed and demonstrated on the Goddard Space Flight Center Computer Facility. Procedures have been outlined to guide the user of the models through specific evaluation processes, and the preparation of inputs describing earth observation needs and earth observation technology. These models are intended to assist NASA in increasing the effectiveness of the overall Earth Observation Program by providing a broader view of system and program development alternatives.
Park, Jinoh; Kim, Hyun-Sook; Hwang, Hye Jeon; Yang, Dong Hyun; Koo, Hyun Jung; Kang, Joon-Won; Kim, Young-Hak
2017-09-01
To evaluate the geographic and demographic variabilities of the quantitative parameters of computed tomography perfusion (CTP) of the left ventricular (LV) myocardium in patients with normal coronary artery on computed tomography angiography (CTA). From a multicenter CTP registry of stress and static computed tomography, we retrospectively recruited 113 patients (mean age, 60 years; 57 men) without perfusion defect on visual assessment and minimal (< 20% of diameter stenosis) or no coronary artery disease on CTA. Using semiautomatic analysis software, quantitative parameters of the LV myocardium, including the myocardial attenuation in stress and rest phases, transmural perfusion ratio (TPR), and myocardial perfusion reserve index (MPRI), were evaluated in 16 myocardial segments. In the lateral wall of the LV myocardium, all quantitative parameters except for MPRI were significantly higher compared with those in the other walls. The MPRI showed consistent values in all myocardial walls (anterior to lateral wall: range, 25% to 27%; p = 0.401). At the basal level of the myocardium, all quantitative parameters were significantly lower than those at the mid- and apical levels. Compared with men, women had significantly higher values of myocardial attenuation and TPR. Age, body mass index, and Framingham risk score were significantly associated with the difference in myocardial attenuation. Geographic and demographic variabilities of quantitative parameters in stress myocardial CTP exist in healthy subjects without significant coronary artery disease. This information may be helpful when assessing myocardial perfusion defects in CTP.
Taylor, Andrew T; Garcia, Ernest V
2014-01-01
The goal of artificial intelligence, expert systems, decision support systems and computer assisted diagnosis (CAD) in imaging is the development and implementation of software to assist in the detection and evaluation of abnormalities, to alert physicians to cognitive biases, to reduce intra and inter-observer variability and to facilitate the interpretation of studies at a faster rate and with a higher level of accuracy. These developments are needed to meet the challenges resulting from a rapid increase in the volume of diagnostic imaging studies coupled with a concurrent increase in the number and complexity of images in each patient data. The convergence of an expanding knowledge base and escalating time constraints increases the likelihood of physician errors. Errors are even more likely when physicians interpret low volume studies such as 99mTc-MAG3 diuretic scans where imagers may have had limited training or experience. Decision support systems include neural networks, case-based reasoning, expert systems and statistical systems. iRENEX (renal expert) is an expert system for diuretic renography that uses a set of rules obtained from human experts to analyze a knowledge base of both clinical parameters and quantitative parameters derived from the renogram. Initial studies have shown that the interpretations provided by iRENEX are comparable to the interpretations of a panel of experts. iRENEX provides immediate patient specific feedback at the time of scan interpretation, can be queried to provide the reasons for its conclusions and can be used as an educational tool to teach trainees to better interpret renal scans. iRENEX also has the capacity to populate a structured reporting module and generate a clear and concise impression based on the elements contained in the report; adherence to the procedural and data entry components of the structured reporting module assures and documents procedural competency. Finally, although the focus is CAD applied to diuretic renography, this review offers a window into the rationale, methodology and broader applications of computer assisted diagnosis in medical imaging. PMID:24484751
Filippini, D; Tejle, K; Lundström, I
2005-08-15
The computer screen photo-assisted technique (CSPT), a method for substance classification based on spectral fingerprinting, which involves just a computer screen and a web camera as measuring platform is used here for the evaluation of a prospective enzyme-linked immunosorbent assay (ELISA). A anti-neutrophil cytoplasm antibodies (ANCA-ELISA) test, typically used for diagnosing patients suffering from chronic inflammatory disorders in the skin, joints, blood vessels and other tissues is comparatively tested with a standard microplate reader and CSPT, yielding equivalent results at a fraction of the instrumental costs. The CSPT approach is discussed as a distributed measuring platform allowing decentralized measurements in routine applications, whereas keeping centralized information management due to its natural network embedded operation.
The effect of magnification loupes on the performance of preclinical dental students.
Maggio, Margrit P; Villegas, Hilda; Blatz, Markus B
2011-01-01
optical magnifying devices such as magnification loupes are increasingly used in clinical practice and educational settings. However, scientific evidence to validate their benefits is limited. This study assessed the effect of dental magnification loupes on psychomotor skill acquisition during a preclinical operative dentistry course. the performance of first-year dental students was assessed during an Advanced Simulation Course (AS) using virtual reality-based technology (VRBT) training. The test group consisted of 116 dental students using magnification loupes (+MAG), while students not using them (-MAG, n = 116) served as the control. The following parameters were evaluated: number of successfully passing preparation procedures per course rotation, amount of time per tooth preparation, number of times students needed computer assistance and evaluation, and amount of time spent in the computer assistance and evaluation mode per procedure. Data were collected on each student through VRBT during the preparation procedure and stored on a closed network server computer. Unpaired t tests were used to analyze mean differences between the groups. In addition, student acceptance of magnification loupes was measured and evaluated through survey interpretation. +MAG students completed more preparations, worked faster per procedure, and used the computer-assisted evaluation less frequently and for shorter periods, therefore displaying greater overall performance. The survey revealed a high degree of student acceptance of using magnification. dental magnification loupes significantly enhanced student performance during preclinical dental education and were considered an effective adjunct by the students who used them.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki
2010-03-01
Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our teleradiology network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
Computer Based Learning in Europe: A Bibliography.
ERIC Educational Resources Information Center
Rushby, N. J.
This bibliography lists 172 references to papers on computer assisted learning (CAL) in European countries including the Soviet Union, Germany, Holland, Sweden, Yugoslavia, Austria, and Italy. The references which deal with such topics as teacher training, simulation, rural education, model construction, program evaluation, computer managed…
Sorg, Heiko; Knobloch, Karsten
2012-01-01
First quantitative evaluation of the requirements for the promotion as associate professor (AP) at German medical faculties. Analysis of the AP-regulations of German medical faculties according to a validated scoring system, which has been adapted to this study. The overall scoring for the AP-requirements at 35 German medical faculties was 13.5±0.6 of 20 possible scoring points (95% confidence interval 12.2-14.7). More than 88% of the AP-regulations demand sufficient performance in teaching and research with adequate scientific publication. Furthermore, 83% of the faculties expect an expert review of the candidate's performance. Conference presentations required as an assistant professor as well as the reduction of the minimum time as an assistant professor do only play minor roles. The requirements for assistant professors to get nominated as an associate professor at German medical faculties are high with an only small range. In detail, however, it can be seen that there still exists large heterogeneity, which hinders equal opportunities and career possibilities. These data might be used for the ongoing objective discussion.
ICCE/ICCAI 2000 Full & Short Papers (Evaluation of Learning and Systems).
ERIC Educational Resources Information Center
2000
This document contains the full and short papers on evaluation of learning and systems from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction) covering the following topics: a new method for efficient study of Kanji using mnemonics and software; a study on the relation…
Evaluation of a Text Compression Algorithm Against Computer-Aided Instruction (CAI) Material.
ERIC Educational Resources Information Center
Knight, Joseph M., Jr.
This report describes the initial evaluation of a text compression algorithm against computer assisted instruction (CAI) material. A review of some concepts related to statistical text compression is followed by a detailed description of a practical text compression algorithm. A simulation of the algorithm was programed and used to obtain…
Evaluating the Motivational Impact of CALL Systems: Current Practices and Future Directions
ERIC Educational Resources Information Center
Bodnar, Stephen; Cucchiarini, Catia; Strik, Helmer; van Hout, Roeland
2016-01-01
A major aim of computer-assisted language learning (CALL) is to create computer environments that facilitate students' second language (L2) acquisition. To achieve this aim, CALL employs technological innovations to create novel types of language practice. Evaluations of the new practice types serve the important role of distinguishing effective…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, A.N.; Graham, M.M.; Ferency, G.F.
1989-04-01
Radioisotope penile plethysmography is a nuclear medicine technique which assists in the evaluation of patients with erectile dysfunction. This technique attempts to noninvasively quantitate penile corpora cavernosal blood flow during early penile tumescence using technetium-99m-labeled red blood cells. Penile images and counts were acquired in a steady-state blood-pool phase prior to and after the administration of intracorporal papaverine. Penile counts, images, and time-activity curves were computer analyzed in order to determine peak corporal flow and volume changes. Peak corporal flow rates were compared to arterial integrity (determined by angiography) and venosinusoidal corporal leak (determined by cavernosometry). Peak corporal flow correlatedmore » well with arterial integrity (r = 0.91) but did not correlate with venosinusoidal leak parameters (r = 0.01). This report focuses on the methodology and the assumptions which form the foundation of this technique. The strong correlation of peak corporal flow and angiography suggests that radioisotope penile plethysmography could prove useful in the evaluation of arterial inflow disorders in patients with erectile dysfunction.« less
White, Mary Jo; Stark, Jennifer R; Luckmann, Roger; Rosal, Milagros C; Clemow, Lynn; Costanza, Mary E
2006-06-01
Computer-assisted telephone interviewing (CATI) systems used by telephone counselors (TCs) may be efficient mechanisms to counsel patients on cancer and recommended preventive screening tests in order to extend a primary care provider's reach to his/her patients. The implementation process of such a system for promoting colorectal (CRC) cancer screening using a computer-assisted telephone interview (CATI) system is reported in this paper. The process evaluation assessed three components of the intervention: message production, program implementation and audience reception. Of 1181 potentially eligible patients, 1025 (87%) patients were reached by the TCs and 725 of those patients (71%) were eligible to receive counseling. Five hundred eighty-two (80%) patients agreed to counseling. It is feasible to design and use CATI systems for prevention counseling of patients in primary care practices. CATI systems have the potential of being used as a referral service by primary care providers and health care organizations for patient education.
Plasma cell quantification in bone marrow by computer-assisted image analysis.
Went, P; Mayer, S; Oberholzer, M; Dirnhofer, S
2006-09-01
Minor and major criteria for the diagnosis of multiple meloma according to the definition of the WHO classification include different categories of the bone marrow plasma cell count: a shift from the 10-30% group to the > 30% group equals a shift from a minor to a major criterium, while the < 10% group does not contribute to the diagnosis. Plasma cell fraction in the bone marrow is therefore critical for the classification and optimal clinical management of patients with plasma cell dyscrasias. The aim of this study was (i) to establish a digital image analysis system able to quantify bone marrow plasma cells and (ii) to evaluate two quantification techniques in bone marrow trephines i.e. computer-assisted digital image analysis and conventional light-microscopic evaluation. The results were compared regarding inter-observer variation of the obtained results. Eighty-seven patients, 28 with multiple myeloma, 29 with monoclonal gammopathy of undetermined significance, and 30 with reactive plasmocytosis were included in the study. Plasma cells in H&E- and CD138-stained slides were quantified by two investigators using light-microscopic estimation and computer-assisted digital analysis. The sets of results were correlated with rank correlation coefficients. Patients were categorized according to WHO criteria addressing the plasma cell content of the bone marrow (group 1: 0-10%, group 2: 11-30%, group 3: > 30%), and the results compared by kappa statistics. The degree of agreement in CD138-stained slides was higher for results obtained using the computer-assisted image analysis system compared to light microscopic evaluation (corr.coeff. = 0.782), as was seen in the intra- (corr.coeff. = 0.960) and inter-individual results correlations (corr.coeff. = 0.899). Inter-observer agreement for categorized results (SM/PW: kappa 0.833) was in a high range. Computer-assisted image analysis demonstrated a higher reproducibility of bone marrow plasma cell quantification. This might be of critical importance for diagnosis, clinical management and prognostics when plasma cell numbers are low, which makes exact quantifications difficult.
Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A
2013-07-01
The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System - PITTCat. Twenty relevant studies were identified. Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators.
Algorithm of pulmonary emphysema extraction using thoracic 3D CT images
NASA Astrophysics Data System (ADS)
Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki
2007-03-01
Recently, due to aging and smoking, emphysema patients are increasing. The restoration of alveolus which was destroyed by emphysema is not possible, thus early detection of emphysema is desired. We describe a quantitative algorithm for extracting emphysematous lesions and quantitatively evaluate their distribution patterns using low dose thoracic 3-D CT images. The algorithm identified lung anatomies, and extracted low attenuation area (LAA) as emphysematous lesion candidates. Applying the algorithm to thoracic 3-D CT images and then by follow-up 3-D CT images, we demonstrate its potential effectiveness to assist radiologists and physicians to quantitatively evaluate the emphysematous lesions distribution and their evolution in time interval changes.
Algorithm of pulmonary emphysema extraction using low dose thoracic 3D CT images
NASA Astrophysics Data System (ADS)
Saita, S.; Kubo, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Omatsu, H.; Tominaga, K.; Eguchi, K.; Moriyama, N.
2006-03-01
Recently, due to aging and smoking, emphysema patients are increasing. The restoration of alveolus which was destroyed by emphysema is not possible, thus early detection of emphysema is desired. We describe a quantitative algorithm for extracting emphysematous lesions and quantitatively evaluate their distribution patterns using low dose thoracic 3-D CT images. The algorithm identified lung anatomies, and extracted low attenuation area (LAA) as emphysematous lesion candidates. Applying the algorithm to 100 thoracic 3-D CT images and then by follow-up 3-D CT images, we demonstrate its potential effectiveness to assist radiologists and physicians to quantitatively evaluate the emphysematous lesions distribution and their evolution in time interval changes.
Computerized Vocational Guidance (CVG) Systems: Evaluation for Use in Military Recruiting.
1984-02-01
how to relate the two, and how to explore, project, and choose. Whether Rogerian or more directive in nature, the essential counseling ingredient is to...Conference, Princeton, NJ: Educational Testing Service, 1974, 43-69. Katz, M. R., & Shatkin, L. Computer-assisted guidance: Concepts and practices (Res. Rep...Canadian Forces Personnel Applied Research Unit, 1980. Katz, M. R., & Shatkin, L. Computer-assisted guidance: Concepts and practices (Res. Rep. RR-80-1
Zhang, Mingming; Meng, Wei; Davies, T Claire; Zhang, Yanxin; Xie, Sheng Q
2016-04-01
Robot-assisted ankle assessment could potentially be conducted using sensor-based and model-based methods. Existing ankle rehabilitation robots usually use torquemeters and multiaxis load cells for measuring joint dynamics. These measurements are accurate, but the contribution as a result of muscles and ligaments is not taken into account. Some computational ankle models have been developed to evaluate ligament strain and joint torque. These models do not include muscles and, thus, are not suitable for an overall ankle assessment in robot-assisted therapy. This study proposed a computational ankle model for use in robot-assisted therapy with three rotational degrees of freedom, 12 muscles, and seven ligaments. This model is driven by robotics, uses three independent position variables as inputs, and outputs an overall ankle assessment. Subject-specific adaptations by geometric and strength scaling were also made to allow for a universal model. This model was evaluated using published results and experimental data from 11 participants. Results show a high accuracy in the evaluation of ligament neutral length and passive joint torque. The subject-specific adaptation performance is high, with each normalized root-mean-square deviation value less than 10%. This model could be used for ankle assessment, especially in evaluating passive ankle torque, for a specific individual. The characteristic that is unique to this model is the use of three independent position variables that can be measured in real time as inputs, which makes it advantageous over other models when combined with robot-assisted therapy.
ERIC Educational Resources Information Center
Box, Melinda C.; Dunnagan, Cathi L.; Hirsh, Lauren A. S.; Cherry, Clinton R.; Christianson, Kayla A.; Gibson, Radiance J.; Wolfe, Michael I.; Gallardo-Williams, Maria T.
2017-01-01
This study was designed to evaluate the effectiveness of student-generated videos as a supplement to teaching assistant (TA) instruction in an undergraduate organic chemistry laboratory. Three videos covering different aspects of lab instruction (experimental technique, use of instrumentation, and calculations) were produced using…
Zhang, Yin; Wang, Lei
2013-01-01
Abstract The Clinical and Translational Science Awards (CTSA) program is one of the most important initiatives in translational medical funding. The quantitative evaluation of the efficiency and performance of the CTSA program has a significant referential meaning for the decision making of global translational medical funding. Using science mapping and scientometric analytic tools, this study quantitatively analyzed the scientific articles funded by the CTSA program. The results of the study showed that the quantitative productivities of the CTSA program had a stable increase since 2008. In addition, the emerging trends of the research funded by the CTSA program covered clinical and basic medical research fields. The academic benefits from the CTSA program were assisting its members to build a robust academic home for the Clinical and Translational Science and to attract other financial support. This study provided a quantitative evaluation of the CTSA program based on science mapping and scientometric analysis. Further research is required to compare and optimize other quantitative methods and to integrate various research results. PMID:24330689
Zhang, Yin; Wang, Lei; Diao, Tianxi
2013-12-01
The Clinical and Translational Science Awards (CTSA) program is one of the most important initiatives in translational medical funding. The quantitative evaluation of the efficiency and performance of the CTSA program has a significant referential meaning for the decision making of global translational medical funding. Using science mapping and scientometric analytic tools, this study quantitatively analyzed the scientific articles funded by the CTSA program. The results of the study showed that the quantitative productivities of the CTSA program had a stable increase since 2008. In addition, the emerging trends of the research funded by the CTSA program covered clinical and basic medical research fields. The academic benefits from the CTSA program were assisting its members to build a robust academic home for the Clinical and Translational Science and to attract other financial support. This study provided a quantitative evaluation of the CTSA program based on science mapping and scientometric analysis. Further research is required to compare and optimize other quantitative methods and to integrate various research results. © 2013 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Reitenour, Steve
The current use of high technology in music instruction was surveyed, and music-related computer programs appropriate for Liberty Baptist College were recommended. Information on 59 programs was gathered and submitted to a panel of three music instructors, who selected 10 programs for further evaluation. A Courseware Evaluation Sheet was used to…
Grunewald, J P; Röhl, F W; Kirches, E; Dietzmann, K
1998-02-01
Many studies dealing with extracranial cancer showed a strong correlation of DNA ploidy to a poor clinical outcome, recurrence, or malignancy. In brain tumors, analysis of DNA content did not always provided significant diagnostic information. In this study, DNA density and karyometric parameters of 50 meningiomas (26 Grade I, 10 Grade II, 14 Grade III) were quantitatively evaluated by digital cell image analyses of Feulgen-stained nuclei. In particular, the densitometric parameter SEXT, which describes nuclear DNA content, as well as the morphometric values LENG (a computer-assisted measurement of nuclear circumference), AREA (a computer-assisted measurement of nuclear area), FCON (a parameter that describes nuclear roundness), and CONC (a describing nuclear contour), evaluated with the software IMAGE C, were correlated to World Health Organization (WHO) grading using univariate and multivariate methods. AREA and LENG values showed significant differences between tumors of Grades I and III. FCON values were unable to distinguish WHO Grade III from Grade I/II but were useful in clearly separating Grade II from Grade I tumors. CONC values detected differences between WHO Grades II and I/III tumors but not between the latter. SEXT values clearly distinguished Grade III from Grade I/II tumors. The 1c, 2c, 2.5c, and 5c exceeding rates showed no predictive values. Only the 6c exceeding rate showed a significant difference between Grades I and III. These results outline the characteristic features of the atypical (Grade II) meningiomas, which make them a recognizable tumor entity distinct from benign and anaplastic meningiomas. The combination of DNA densitometric and morphometric findings seems to be a powerful addition to the histopathologic classification of meningiomas, as suggested by the WHO.
Chang, Shao-Hsia; Yu, Nan-Ying
2014-07-01
The objective of this study was to compare the effect of computer-assisted practice with the sensorimotor approach on the remediation of handwriting problems in children with dysgraphia. In a randomized controlled trial, experiments were conducted to verify the intervention effect. Forty two children with handwriting deficit were assigned to computer-assisted instruction, sensorimotor training, or a control group. Handwriting performance was measured using the elementary reading/writing test and computerized handwriting evaluation before and after 6 weeks of intervention. Repeated-measures ANOVA of changed scores were conducted to show whether statistically significant differences across the three groups were present. Significant differences in the elementary reading/writing test were found among the three groups. The computer group showed more significant improvements than the other two groups did. In the kinematic and kinetic analyses, the computer group showed promising results in the remediation of handwriting speed and fluency. This study provided clinical evidence for applying a computer-assisted handwriting program for children with dysgraphia. Clinicians and school teachers are provided with a systematic intervention for the improvement of handwriting difficulties. Copyright © 2014 Elsevier Ltd. All rights reserved.
Miyaki, Rie; Yoshida, Shigeto; Tanaka, Shinji; Kominami, Yoko; Sanomura, Yoji; Matsuo, Taiji; Oka, Shiro; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsushi; Kaneda, Kazufumi; Yoshihara, Masaharu; Chayama, Kazuaki
2015-02-01
To evaluate the usefulness of a newly devised computer system for use with laser-based endoscopy in differentiating between early gastric cancer, reddened lesions, and surrounding tissue. Narrow-band imaging based on laser light illumination has come into recent use. We devised a support vector machine (SVM)-based analysis system to be used with the newly devised endoscopy system to quantitatively identify gastric cancer on images obtained by magnifying endoscopy with blue-laser imaging (BLI). We evaluated the usefulness of the computer system in combination with the new endoscopy system. We evaluated the system as applied to 100 consecutive early gastric cancers in 95 patients examined by BLI magnification at Hiroshima University Hospital. We produced a set of images from the 100 early gastric cancers; 40 flat or slightly depressed, small, reddened lesions; and surrounding tissues, and we attempted to identify gastric cancer, reddened lesions, and surrounding tissue quantitatively. The average SVM output value was 0.846 ± 0.220 for cancerous lesions, 0.381 ± 0.349 for reddened lesions, and 0.219 ± 0.277 for surrounding tissue, with the SVM output value for cancerous lesions being significantly greater than that for reddened lesions or surrounding tissue. The average SVM output value for differentiated-type cancer was 0.840 ± 0.207 and for undifferentiated-type cancer was 0.865 ± 0.259. Although further development is needed, we conclude that our computer-based analysis system used with BLI will identify gastric cancers quantitatively.
NASA Astrophysics Data System (ADS)
Chaisaowong, Kraisorn; Jiang, Mingze; Faltin, Peter; Merhof, Dorit; Eisenhawer, Christian; Gube, Monika; Kraus, Thomas
2016-03-01
Pleural thickenings are caused by asbestos exposure and may evolve into malignant pleural mesothelioma. An early diagnosis plays a key role towards an early treatment and an increased survival rate. Today, pleural thickenings are detected by visual inspection of CT data, which is time-consuming and underlies the physician's subjective judgment. A computer-assisted diagnosis system to automatically assess pleural thickenings has been developed, which includes not only a quantitative assessment with respect to size and location, but also enhances this information with an anatomical description, i.e. lung side (left, right), part of pleura (pars costalis, mediastinalis, diaphragmatica, spinalis), as well as vertical (upper, middle, lower) and horizontal (ventral, dorsal) position. For this purpose, a 3D anatomical model of the lung surface has been manually constructed as a 3D atlas. Three registration sub-steps including rigid, affine, and nonrigid registration align the input patient lung to the 3D anatomical atlas model of the lung surface. Finally, each detected pleural thickening is assigned a set of labels describing its anatomical properties. Through this added information, an enhancement to the existing computer-assisted diagnosis system is presented in order to assure a higher precision and reproducible assessment of pleural thickenings, aiming at the diagnosis of the pleural mesothelioma in its early stage.
Users' evaluation of the Navy Computer-Assisted Medical Diagnosis System.
Merrill, L L; Pearsall, D M; Gauker, E D
1996-01-01
U.S. Navy Independent Duty Corpsmen (IDCs) aboard small ships and submarines are responsible for all clinical and related health care duties while at sea. During deployment, life-threatening illnesses sometimes require evacuation to a shore-based treatment facility. At-sea evacuations are dangerous, expensive, and may compromise the mission of the vessel. Therefore, Group Medical Officers and IDCs were trained to use the Navy Computer-Assisted Medical Diagnosis (NCAMD) system during deployment. They were then surveyed to evaluate the NCAMD system. Their responses show that NCAMD is a cost-efficient, user-friendly package. It is easy to learn, and is especially valuable for training in the diagnosis of chest and abdominal complaints. However, the delivery of patient care at sea would significantly improve if computer hardware were upgraded to current industry standards. Also, adding various computer peripheral devices, structured forms, and reference materials to the at-sea clinician's resources could enhance shipboard patient care.
Using Computer-Assisted Assessment Heuristics for Usability Evaluations
ERIC Educational Resources Information Center
Sim, Gavin; Read, Janet C.
2016-01-01
Teaching practices within educational institutions have evolved through the increased adoption of technology to deliver the curriculum and the use of computers for assessment purposes. For educational technologists, there is a vast array of commercial computer applications available for the delivery of objective tests, and in some instances,…
Metocognitive Support Accelerates Computer Assisted Learning for Novice Programmers
ERIC Educational Resources Information Center
Rum, Siti Nurulain Mohd; Ismail, Maizatul Akmar
2017-01-01
Computer programming is a part of the curriculum in computer science education, and high drop rates for this subject are a universal problem. Development of metacognitive skills, including the conceptual framework provided by socio-cognitive theories that afford reflective thinking, such as actively monitoring, evaluating, and modifying one's…
Quantitative Evaluation of a Planetary Renderer for Terrain Relative Navigation
NASA Astrophysics Data System (ADS)
Amoroso, E.; Jones, H.; Otten, N.; Wettergreen, D.; Whittaker, W.
2016-11-01
A ray-tracing computer renderer tool is presented based on LOLA and LROC elevation models and is quantitatively compared to LRO WAC and NAC images for photometric accuracy. We investigated using rendered images for terrain relative navigation.
Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M
2016-08-01
Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.
ERIC Educational Resources Information Center
Berney, Tomi D.; Keyes, Jose L.
The Computer Writing Skills for Limited English Proficient Students (Project COMPUGRAFIA.LEP), bilingual special education classes totalling 375 Spanish-speaking students at 10 elementary schools in the Bronx, is evaluated. The project proposed to assist site teachers in developing appropriate lesson plans and effective teaching techniques and…
Ammenwerth, Elske; Mansmann, Ulrich; Iller, Carola; Eichstädter, Ronald
2003-01-01
The documentation of the nursing process is an important but often neglected part of clinical documentation. Paper-based systems have been introduced to support nursing process documentation. Frequently, however, problems such as low quality of documentation are reported. It is unclear whether computer-based documentation systems can reduce these problems and which factors influence their acceptance by users. We introduced a computer-based nursing documentation system on four wards of the University Hospitals of Heidelberg and systematically evaluated its preconditions and its effects in a pretest-posttest intervention study. For the analysis of user acceptance, we concentrated on subjective data drawn from questionnaires and interviews. A questionnaire was developed using items from published questionnaires and items that had to be developed for the special purpose of this study. The quantitative results point to two factors influencing the acceptance of a new computer-based documentation system: the previous acceptance of the nursing process and the previous amount of self-confidence when using computers. On one ward, the diverse acceptance scores heavily declined after the introduction of the nursing documentation system. Explorative qualitative analysis on this ward points to further success factors of computer-based nursing documentation systems. Our results can be used to assist the planning and introduction of computer-based nursing documentation systems. They demonstrate the importance of computer experience and acceptance of the nursing process on a ward but also point to other factors such as the fit between nursing workflow and the functionality of a nursing documentation system.
The use of computer imaging techniques to visualize cardiac muscle cells in three dimensions.
Marino, T A; Cook, P N; Cook, L T; Dwyer, S J
1980-11-01
Atrial muscle cells and atrioventricular bundle cells were reconstructed using a computer-assisted three-dimensional reconstruction system. This reconstruction technique permitted these cells to be viewed from any direction. The cell surfaces were approximated using triangular tiles, and this optimization technique for cell reconstruction allowed for the computation of cell surface area and cell volume. A transparent mode is described which enables the investigator to examine internal cellular features such as the shape and location of the nucleus. In addition, more than one cell can be displayed simultaneously, and, therefore, spatial relationships are preserved and intercellular relationships viewed directly. The use of computer imaging techniques allows for a more complete collection of quantitative morphological data and also the visualization of the morphological information gathered.
Abstracts Produced Using Computer Assistance.
ERIC Educational Resources Information Center
Craven, Timothy C.
2000-01-01
Describes an experiment that evaluated features of TEXNET abstracting software, compared the use of keywords and phrases that were automatically extracted, tested hypotheses about relations between abstractors' backgrounds and their reactions to abstracting assistance software, and obtained ideas for further features to be developed in TEXNET.…
On the tip of the tongue: learning typing and pointing with an intra-oral computer interface.
Caltenco, Héctor A; Breidegard, Björn; Struijk, Lotte N S Andreasen
2014-07-01
To evaluate typing and pointing performance and improvement over time of four able-bodied participants using an intra-oral tongue-computer interface for computer control. A physically disabled individual may lack the ability to efficiently control standard computer input devices. There have been several efforts to produce and evaluate interfaces that provide individuals with physical disabilities the possibility to control personal computers. Training with the intra-oral tongue-computer interface was performed by playing games over 18 sessions. Skill improvement was measured through typing and pointing exercises at the end of each training session. Typing throughput improved from averages of 2.36 to 5.43 correct words per minute. Pointing throughput improved from averages of 0.47 to 0.85 bits/s. Target tracking performance, measured as relative time on target, improved from averages of 36% to 47%. Path following throughput improved from averages of 0.31 to 0.83 bits/s and decreased to 0.53 bits/s with more difficult tasks. Learning curves support the notion that the tongue can rapidly learn novel motor tasks. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, which makes the tongue a feasible input organ for computer control. Intra-oral computer interfaces could provide individuals with severe upper-limb mobility impairments the opportunity to control computers and automatic equipment. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, but does not cause fatigue easily and might be invisible to other people, which is highly prioritized by assistive device users. Combination of visual and auditory feedback is vital for a good performance of an intra-oral computer interface and helps to reduce involuntary or erroneous activations.
Models and techniques for evaluating the effectiveness of aircraft computing systems
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1982-01-01
Models, measures, and techniques for evaluating the effectiveness of aircraft computing systems were developed. By "effectiveness" in this context we mean the extent to which the user, i.e., a commercial air carrier, may expect to benefit from the computational tasks accomplished by a computing system in the environment of an advanced commercial aircraft. Thus, the concept of effectiveness involves aspects of system performance, reliability, and worth (value, benefit) which are appropriately integrated in the process of evaluating system effectiveness. Specifically, the primary objectives are: the development of system models that provide a basis for the formulation and evaluation of aircraft computer system effectiveness, the formulation of quantitative measures of system effectiveness, and the development of analytic and simulation techniques for evaluating the effectiveness of a proposed or existing aircraft computer.
Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K
2011-04-01
Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual measurements, while interobserver APAs ranged from 91% to 96% for QMA versus 57% to 63% for digitized manual measurements. The use of QMA software substantially improved the reliability of lumbar intervertebral measurements and the classification of instability based on flexion-extension radiographs.
Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros
2018-02-01
Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.
Optothermal response of a single silicon nanotip
NASA Astrophysics Data System (ADS)
Vella, A.; Shinde, D.; Houard, J.; Silaeva, E.; Arnoldi, L.; Blum, I.; Rigutti, L.; Pertreux, E.; Maioli, P.; Crut, A.; Del Fatti, N.
2018-02-01
The optical properties and thermal dynamics of conical single silicon nanotips are experimentally and theoretically investigated. The spectral and spatial dependencies of their optical extinction are quantitatively measured by spatial modulation spectroscopy (SMS). A nonuniform optical extinction along the tip axis and an enhanced near-infrared absorption, as compared to bulk crystalline silicon, are evidenced. This information is a key input for computing the thermal response of single silicon nanotips under ultrafast laser illumination, which is investigated by laser assisted atom probe tomography (La-APT) used as a highly sensitive temperature probe. A combination of these two experimental techniques and comparison with modeling also permits us to elucidate the impact of thermal effects on the laser assisted field evaporation process. Extension of this coupled approach opens up future perspectives for the quantitative study of the optical and thermal properties of a wide class of individual nano-objects, in particular elongated ones such as nanotubes, nanowires, and nanocones, which constitute promising nanosources for electron and/or ion emission.
Albert, Réka; Vásárhelyi, Gábor; Bodó, Gábor; Kenyeres, Annamária; Wolf, Ervin; Papp, Tamás; Terdik, Tünde; Módis, László; Felszeghy, Szabolcs
2012-09-01
One of the most promising applications for the restoration of small or moderately sized focal articular lesions is mosaicplasty (MP). Although recurrent hemarthrosis is a rare complication after MP, recently, various strategies have been designed to find an effective filling material to prevent postoperative bleeding from the donor site. The porous biodegradable polymer Polyactive (PA; a polyethylene glycol terephthalate - polybutylene terephthalate copolymer) represents a promising solution in this respect. A histological evaluation of the longterm PA-filled donor sites obtained from 10 experimental horses was performed. In this study, attention was primarily focused on the bone tissue developed in the plug. A computer-assisted image analysis and quantitative polarized light microscopic measurements of decalcified, longitudinally sectioned, dimethylmethylene blue (DMMB)- and picrosirius red (PS) stained sections revealed that the coverage area of the bone trabecules in the PA-filled donor tunnels was substantially (25%) enlarged compared to the neighboring cancellous bone. For this quantification, identical ROIs (regions of interest) were used and compared. The birefringence retardation values were also measured with a polarized light microscope using monochromatic light. Identical retardation values could be recorded from the bone trabeculae developed in the PA and in the neighboring bone, which indicates that the collagen orientation pattern does not differ significantly among these bone trabecules. Based on our new data, we speculate that PA promotes bone formation, and some of the currently identified degradation products of PA may enhance osteo-conduction and osteoinduction inside the donor canal.
Image segmentation evaluation for very-large datasets
NASA Astrophysics Data System (ADS)
Reeves, Anthony P.; Liu, Shuang; Xie, Yiting
2016-03-01
With the advent of modern machine learning methods and fully automated image analysis there is a need for very large image datasets having documented segmentations for both computer algorithm training and evaluation. Current approaches of visual inspection and manual markings do not scale well to big data. We present a new approach that depends on fully automated algorithm outcomes for segmentation documentation, requires no manual marking, and provides quantitative evaluation for computer algorithms. The documentation of new image segmentations and new algorithm outcomes are achieved by visual inspection. The burden of visual inspection on large datasets is minimized by (a) customized visualizations for rapid review and (b) reducing the number of cases to be reviewed through analysis of quantitative segmentation evaluation. This method has been applied to a dataset of 7,440 whole-lung CT images for 6 different segmentation algorithms designed to fully automatically facilitate the measurement of a number of very important quantitative image biomarkers. The results indicate that we could achieve 93% to 99% successful segmentation for these algorithms on this relatively large image database. The presented evaluation method may be scaled to much larger image databases.
An Evaluation Framework for CALL
ERIC Educational Resources Information Center
McMurry, Benjamin L.; Williams, David Dwayne; Rich, Peter J.; Hartshorn, K. James
2016-01-01
Searching prestigious Computer-assisted Language Learning (CALL) journals for references to key publications and authors in the field of evaluation yields a short list. The "American Journal of Evaluation"--the flagship journal of the American Evaluation Association--is only cited once in both the "CALICO Journal and Language…
Reslan, Summar; Axelrod, Bradley N
2017-01-01
The purpose of the current study was to compare three potential profiles of the Medical Symptom Validity Test (MSVT; Pass, Genuine Memory Impairment Profile [GMIP], and Fail) on other freestanding and embedded performance validity tests (PVTs). Notably, a quantitatively computed version of the GMIP was utilized in this investigation. Data obtained from veterans referred for a neuropsychological evaluation in a metropolitan Veteran Affairs medical center were included (N = 494). Individuals age 65 and older were not included to exclude individuals with dementia from this investigation. The sample revealed 222 (45%) in the Pass group. Of the 272 who failed the easy subtests of the MSVT, 221 (81%) met quantitative criteria for the GMIP and 51 (19%) were classified as Fail. The Pass group failed fewer freestanding and embedded PVTs and obtained higher raw scores on all PVTs than both GMIP and Fail groups. The differences in performances of the GMIP and Fail groups were minimal. Specifically, GMIP protocols failed fewer freestanding PVTs than the Fail group; failure on embedded PVTs did not differ between GMIP and Fail. The MSVT GMIP incorporates the presence of clinical correlates of disability to assist with this distinction, but future research should consider performances on other freestanding measures of performance validity to differentiate cognitive impairment from invalidity.
Computers in Bilingual Education, Project CIBE, 1987-88. Evaluation Section Report. OREA Report.
ERIC Educational Resources Information Center
Berney, Tomi D.; Alvarez, Rosalyn
Computers in Bilingual Education (Project CIBE) was fully implemented at South Bronx High School in its fourth year of federal funding. During the 1987-88 school year, students received computer-assisted and classroom instruction in English as a Second Language (ESL), native language arts (NLA), social studies, mathematics, science, computer…
Beyond the Computer: Reading as a Process of Intellectual Development.
ERIC Educational Resources Information Center
Thompson, Mark E.
With more than 100,000 computers in public schools across the United States, the impact of computer assisted instruction (CAI) on students' reading behavior needs to be evaluated. In reading laboratories, CAI has been found to provide an efficient and highly motivating means of teaching specific educational objectives. Yet, while computer…
Mao, Xiaoyan; Fu, Xi; Niu, Feng; Chen, Ying; Jin, Qi; Qiao, Jia; Gui, Lai
2018-05-14
Reduction gonioplasty is very popular in East Asia. However, there has been little quantitative criteria for mandibular angle classification or aesthetics. The aim of this study was to investigate the quantitative differences of mandibular angle types and determine the morphologic features of mandibular angle in attractive women. We created a database of skull computed tomography and standardized frontal and lateral photographs of 96 Chinese female adults. Mandibular angle was classified into 3 groups, namely, extraversion, introversion, and healthy group, based on the position of gonion. We used a 5-point Likert scale to quantify attractiveness based on photographs. Those who scored 4 or higher were defined as attractive women. Three types of computed tomography measurements of the mandible were taken, including 4 distances, 4 angles, and 3 proportions. Discriminant analysis was applied to establish a mathematic model for mandibular angle aesthetics evaluation. Significant differences were observed between the different types of mandibular angle in lower facial width (Gol-Gor), mandibular angle (Co-Go-Me), and gonion divergence angle (Gol-Me-Gor) (P < 0.01). Chinese attractive women had a mandibular angle of 123.913 ± 2.989 degrees, a FH-MP of 27.033 ± 2.695 degrees, and a Go-Me/Co-Go index of 2.0. The "healthy" women had a mandibular angle of 116.402 ± 5.373 degrees, a FH-MP of 19.556 ± 5.999 degrees, and a Go-Me/Co-Go index of 1.6. The estimated Fisher linear discriminant function for the identification of attractive women was as follows: Y = -0.1516X1(Co-Go) + 0.128X2(Go-Me) + 0.04936X3(Co-Go-Me) +0.0218X4(FH-MP). Our study quantified the differences of mandibular angle types and identified the morphological features of mandibular angle in attractive Chinese female adults. Our results could assist plastic surgeons in presurgical designing of new aesthetic gonion and help to evaluate lower face aesthetics.
A computer program for evaluating long-term forestry investments.
Dennis L. Schweitzer; Allen L. Lundgren; Robert F. Wambach
1967-01-01
Describes a computer program, written in FORTRAN, which has been developed to assist in evaluating long-term forestry investments. A series of discount rates are used to calculate the internal rate of return and discounted costs, incomes, and net worth for any investments specified by the user. The features of the program are illustrated and discussed in detail, and...
ERIC Educational Resources Information Center
Herrera-Viedma, Enrique; Peis, Eduardo
2003-01-01
Presents a fuzzy evaluation method of SGML documents based on computing with words. Topics include filtering the amount of information available on the Web to assist users in their search processes; document type definitions; linguistic modeling; user-system interaction; and use with XML and other markup languages. (Author/LRW)
Computer-Aided Group Problem Solving for Unified Life Cycle Engineering (ULCE)
1989-02-01
defining the problem, generating alternative solutions, evaluating alternatives, selecting alternatives, and implementing the solution. Systems...specialist in group dynamics, assists the group in formulating the problem and selecting a model framework. The analyst provides the group with computer...allocating resources, evaluating and selecting options, making judgments explicit, and analyzing dynamic systems. c. University of Rhode Island Drs. Geoffery
A method for evaluating the murine pulmonary vasculature using micro-computed tomography.
Phillips, Michael R; Moore, Scott M; Shah, Mansi; Lee, Clara; Lee, Yueh Z; Faber, James E; McLean, Sean E
2017-01-01
Significant mortality and morbidity are associated with alterations in the pulmonary vasculature. While techniques have been described for quantitative morphometry of whole-lung arterial trees in larger animals, no methods have been described in mice. We report a method for the quantitative assessment of murine pulmonary arterial vasculature using high-resolution computed tomography scanning. Mice were harvested at 2 weeks, 4 weeks, and 3 months of age. The pulmonary artery vascular tree was pressure perfused to maximal dilation with a radio-opaque casting material with viscosity and pressure set to prevent capillary transit and venous filling. The lungs were fixed and scanned on a specimen computed tomography scanner at 8-μm resolution, and the vessels were segmented. Vessels were grouped into categories based on lumen diameter and branch generation. Robust high-resolution segmentation was achieved, permitting detailed quantitation of pulmonary vascular morphometrics. As expected, postnatal lung development was associated with progressive increase in small-vessel number and arterial branching complexity. These methods for quantitative analysis of the pulmonary vasculature in postnatal and adult mice provide a useful tool for the evaluation of mouse models of disease that affect the pulmonary vasculature. Copyright © 2016 Elsevier Inc. All rights reserved.
Wu, Z J; Xu, B; Jiang, H; Zheng, M; Zhang, M; Zhao, W J; Cheng, J
2016-08-20
Objective: To investigate the application of United States Environmental Protection Agency (EPA) inhalation risk assessment model, Singapore semi-quantitative risk assessment model, and occupational hazards risk assessment index method in occupational health risk in enterprises using dimethylformamide (DMF) in a certain area in Jiangsu, China, and to put forward related risk control measures. Methods: The industries involving DMF exposure in Jiangsu province were chosen as the evaluation objects in 2013 and three risk assessment models were used in the evaluation. EPA inhalation risk assessment model: HQ=EC/RfC; Singapore semi-quantitative risk assessment model: Risk= (HR×ER) 1/2 ; Occupational hazards risk assessment index=2 Health effect level ×2 exposure ratio ×Operation condition level. Results: The results of hazard quotient (HQ>1) from EPA inhalation risk assessment model suggested that all the workshops (dry method, wet method and printing) and work positions (pasting, burdening, unreeling, rolling, assisting) were high risk. The results of Singapore semi-quantitative risk assessment model indicated that the workshop risk level of dry method, wet method and printing were 3.5 (high) , 3.5 (high) and 2.8 (general) , and position risk level of pasting, burdening, unreeling, rolling, assisting were 4 (high) , 4 (high) , 2.8 (general) , 2.8 (general) and 2.8 (general) . The results of occupational hazards risk assessment index method demonstrated that the position risk index of pasting, burdening, unreeling, rolling, assisting were 42 (high) , 33 (high) , 23 (middle) , 21 (middle) and 22 (middle) . The results of Singapore semi-quantitative risk assessment model and occupational hazards risk assessment index method were similar, while EPA inhalation risk assessment model indicated all the workshops and positions were high risk. Conclusion: The occupational hazards risk assessment index method fully considers health effects, exposure, and operating conditions and can comprehensively and accurately evaluate occupational health risk caused by DMF.
Metrics for comparing dynamic earthquake rupture simulations
Barall, Michael; Harris, Ruth A.
2014-01-01
Earthquakes are complex events that involve a myriad of interactions among multiple geologic features and processes. One of the tools that is available to assist with their study is computer simulation, particularly dynamic rupture simulation. A dynamic rupture simulation is a numerical model of the physical processes that occur during an earthquake. Starting with the fault geometry, friction constitutive law, initial stress conditions, and assumptions about the condition and response of the near‐fault rocks, a dynamic earthquake rupture simulation calculates the evolution of fault slip and stress over time as part of the elastodynamic numerical solution (Ⓔ see the simulation description in the electronic supplement to this article). The complexity of the computations in a dynamic rupture simulation make it challenging to verify that the computer code is operating as intended, because there are no exact analytic solutions against which these codes’ results can be directly compared. One approach for checking if dynamic rupture computer codes are working satisfactorily is to compare each code’s results with the results of other dynamic rupture codes running the same earthquake simulation benchmark. To perform such a comparison consistently, it is necessary to have quantitative metrics. In this paper, we present a new method for quantitatively comparing the results of dynamic earthquake rupture computer simulation codes.
NASA Technical Reports Server (NTRS)
Baker, V. R. (Principal Investigator); Holz, R. K.; Hulke, S. D.; Patton, P. C.; Penteado, M. M.
1975-01-01
The author has identified the following significant results. Development of a quantitative hydrogeomorphic approach to flood hazard evaluation was hindered by (1) problems of resolution and definition of the morphometric parameters which have hydrologic significance, and (2) mechanical difficulties in creating the necessary volume of data for meaningful analysis. Measures of network resolution such as drainage density and basin Shreve magnitude indicated that large scale topographic maps offered greater resolution than small scale suborbital imagery and orbital imagery. The disparity in network resolution capabilities between orbital and suborbital imagery formats depends on factors such as rock type, vegetation, and land use. The problem of morphometric data analysis was approached by developing a computer-assisted method for network analysis. The system allows rapid identification of network properties which can then be related to measures of flood response.
Quantitative analysis in spontaneous canine anal sac gland adenomas and carcinomas.
Simeonov, Radostin; Simeonova, Galina
2008-12-01
Stained cytological specimens from 7 canine anal sac gland adenomas and 11 canine anal sac gland carcinomas were analyzed by computer-assisted nuclear morphometry. In each case, the nuclei of at least 100 neoplastic cells were measured, and the mean nuclear area (MNA), mean nuclear perimeter (MNP), mean nuclear diameter (MND) and nuclear roundness (NR) were calculated. The study aimed to evaluate (1) the possibility of using nuclear cytomorphometry as an auxiliary diagnostic method to differentiate between canine anal sac gland adenomas and adenocarcinomas, and (2) the prognostic value of nuclear morphometry in canine anal sac gland adenocarcinomas. The results indicated that (1) MNA, MNP, MND and NR could be used as effective auxiliary tools for differential diagnosis between canine anal sac gland adenomas and adenocarcinomas, and (2) MNA, MNP and MND are reliable prognostic indicators for canine anal sac gland adenocarcinomas.
Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A.
2013-01-01
Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators. PMID:23820143
Winters, J M
1995-01-01
A perspective is offered on rehabilitation engineering educational strategies, with a focus on the bachelor's and master's levels. Ongoing changes in engineering education are summarized, especially as related to the integration of design and computers throughout the curriculum; most positively affect rehabilitation engineering training. The challenge of identifying long-term "niches" for rehabilitation engineers within a changing rehabilitation service delivery process is addressed. Five key training components are identified and developed: core science and engineering knowledge, synthesized open-ended problem-solving skill development, hands-on design experience, rehabilitation breadth exposure, and a clinical internship. Two unique abilities are identified that help demarcate the engineer from other providers: open-ended problem-solving skills that include quantitative analysis when appropriate, and objective quantitative evaluation of human performance. Educational strategies for developing these abilities are addressed. Finally, a case is made for training "hybrid" engineers/therapists, in particular bachelor-level engineers who go directly to graduate school to become certified orthotists/prosthetists or physical/occupational therapists, pass the RESNA-sponsored assistive technology service provision exam along the way, then later in life obtain a professional engineer's license and an engineering master's degree.
Ettlin, Dominik A; Sommer, Isabelle; Brönnimann, Ben; Maffioletti, Sergio; Scheidt, Jörg; Hou, Mei-Yin; Lukic, Nenad; Steiger, Beat
2016-12-01
Medical symptoms independent of body location burden individuals to varying degrees and may require care by more than one expert. Various paper and computer-based tools exist that aim to comprehensively capture data for optimal clinical management and research. A web-based interdisciplinary symptom evaluation (WISE) was newly designed, constructed, and technically implemented. For worldwide applicability and to avoid copyright infringements, open source software tools and free validated questionnaires available in multiple languages were used. Highly secure data storage limits access strictly to those who use the tool for collecting, storing, and evaluating their data. Concept and implementation is illustrated by a WISE sample tailored for the requirements of a single center in Switzerland providing interdisciplinary care to orofacial pain and temporomandibular disorder patients. By combining a symptom- burden checklist with in-depth questionnaires serving as case-finding instruments, an algorithm was developed that assists in clarifying case complexity and need for targeted expert evaluation. This novel modular approach provides a personalized, response-tailored instrument for the time- and cost-effective collection of symptom-burden focused quantitative data. The tool includes body drawing options and instructional videos. It is applicable for biopsychosocial evaluation in a variety of clinical settings and offers direct feedback by a case report summary. In clinical practice, the new instrument assists in clarifying case complexity and referral need, based on symptom burden and response -tailored case finding. It provides single-case summary reports from a biopsychosocial perspective and includes graphical symptom maps. Secure, centrally stored data collection of anonymous data is possible. The tool enables personalized medicine, facilitates interprofessional education and collaboration, and allows for multicenter patient-reported outcomes research.
Adoption of computer-assisted learning in medical education: the educators' perspective.
Schifferdecker, Karen E; Berman, Norm B; Fall, Leslie H; Fischer, Martin R
2012-11-01
Computer-assisted learning (CAL) in medical education has been shown to be effective in the achievement of learning outcomes, but requires the input of significant resources and development time. This study examines the key elements and processes that led to the widespread adoption of a CAL program in undergraduate medical education, the Computer-assisted Learning in Paediatrics Program (CLIPP). It then considers the relative importance of elements drawn from existing theories and models for technology adoption and other studies on CAL in medical education to inform the future development, implementation and testing of CAL programs in medical education. The study used a mixed-methods explanatory design. All paediatric clerkship directors (CDs) using CLIPP were recruited to participate in a self-administered, online questionnaire. Semi-structured interviews were then conducted with a random sample of CDs to further explore the quantitative results. Factors that facilitated adoption included CLIPP's ability to fill gaps in exposure to core clinical problems, the use of a national curriculum, development by CDs, and the meeting of CDs' desires to improve teaching and student learning. An additional facilitating factor was that little time and effort were needed to implement CLIPP within a clerkship. The quantitative findings were mostly corroborated by the qualitative findings. This study indicates issues that are important in the consideration and future exploration of the development and implementation of CAL programs in medical education. The promise of CAL as a method of enhancing the process and outcomes of medical education, and its cost, increase the need for future CAL funders and developers to pay equal attention to the needs of potential adopters and the development process as they do to the content and tools in the CAL program. Important questions that remain on the optimal design, use and integration of CAL should be addressed in order to adequately inform future development. Support is needed for studies that address these critical areas. © Blackwell Publishing Ltd 2012.
Dakua, Sarada Prasad; Abinahed, Julien; Al-Ansari, Abdulla
2015-01-01
Abstract. Liver segmentation continues to remain a major challenge, largely due to its intense complexity with surrounding anatomical structures (stomach, kidney, and heart), high noise level and lack of contrast in pathological computed tomography (CT) data. We present an approach to reconstructing the liver surface in low contrast CT. The main contributions are: (1) a stochastic resonance-based methodology in discrete cosine transform domain is developed to enhance the contrast of pathological liver images, (2) a new formulation is proposed to prevent the object boundary, resulting from the cellular automata method, from leaking into the surrounding areas of similar intensity, and (3) a level-set method is suggested to generate intermediate segmentation contours from two segmented slices distantly located in a subject sequence. We have tested the algorithm on real datasets obtained from two sources, Hamad General Hospital and medical image computing and computer-assisted interventions grand challenge workshop. Various parameters in the algorithm, such as w, Δt, z, α, μ, α1, and α2, play imperative roles, thus their values are precisely selected. Both qualitative and quantitative evaluation performed on liver data show promising segmentation accuracy when compared with ground truth data reflecting the potential of the proposed method. PMID:26158101
The use of wireless laptop computers for computer-assisted learning in pharmacokinetics.
Munar, Myrna Y; Singh, Harleen; Belle, Donna; Brackett, Carolyn C; Earle, Sandra B
2006-02-15
To implement computer-assisted learning workshops into pharmacokinetics courses in a doctor of pharmacy (PharmD) program. Workshops were designed for students to utilize computer software programs on laptop computers to build pharmacokinetic models to predict drug concentrations resulting from various dosage regimens. In addition, students were able to visualize through graphing programs how altering different parameters changed drug concentration-time curves. Surveys were conducted to measure students' attitudes toward computer technology before and after implementation. Finally, traditional examinations were used to evaluate student learning. Doctor of pharmacy students responded favorably to the use of wireless laptop computers in problem-based pharmacokinetic workshops. Eighty-eight percent (n = 61/69) and 82% (n = 55/67) of PharmD students completed surveys before and after computer implementation, respectively. Prior to implementation, 95% of students agreed that computers would enhance learning in pharmacokinetics. After implementation, 98% of students strongly agreed (p < 0.05) that computers enhanced learning. Examination results were significantly higher after computer implementation (89% with computers vs. 84% without computers; p = 0.01). Implementation of wireless laptop computers in a pharmacokinetic course enabled students to construct their own pharmacokinetic models that could respond to changing parameters. Students had greater comprehension and were better able to interpret results and provide appropriate recommendations. Computer-assisted pharmacokinetic techniques can be powerful tools when making decisions about drug therapy.
The Use of Wireless Laptop Computers for Computer-Assisted Learning in Pharmacokinetics
Munar, Myrna Y.; Singh, Harleen; Belle, Donna; Brackett, Carolyn C.; Earle, Sandra B.
2006-01-01
Objective To implement computer-assisted learning workshops into pharmacokinetics courses in a doctor of pharmacy (PharmD) program. Design Workshops were designed for students to utilize computer software programs on laptop computers to build pharmacokinetic models to predict drug concentrations resulting from various dosage regimens. In addition, students were able to visualize through graphing programs how altering different parameters changed drug concentration-time curves. Surveys were conducted to measure students’ attitudes toward computer technology before and after implementation. Finally, traditional examinations were used to evaluate student learning. Assessment Doctor of pharmacy students responded favorably to the use of wireless laptop computers in problem-based pharmacokinetic workshops. Eighty-eight percent (n = 61/69) and 82% (n = 55/67) of PharmD students completed surveys before and after computer implementation, respectively. Prior to implementation, 95% of students agreed that computers would enhance learning in pharmacokinetics. After implementation, 98% of students strongly agreed (p < 0.05) that computers enhanced learning. Examination results were significantly higher after computer implementation (89% with computers vs. 84% without computers; p = 0.01). Conclusion Implementation of wireless laptop computers in a pharmacokinetic course enabled students to construct their own pharmacokinetic models that could respond to changing parameters. Students had greater comprehension and were better able to interpret results and provide appropriate recommendations. Computer-assisted pharmacokinetic techniques can be powerful tools when making decisions about drug therapy. PMID:17136147
[Health technology assessment report: Computer-assisted Pap test for cervical cancer screening].
Della Palma, Paolo; Moresco, Luca; Giorgi Rossi, Paolo
2012-01-01
HEALTH PROBLEM: Cervical cancer is a disease which is highly preventable by means of Pap test screening for the precancerous lesions, which can be easily treated. Furthermore, in the near future, control of the disease will be enhanced by the vaccination which prevents the infection of those human papillomavirus types that cause the vast majority of cervical cancers. The effectiveness of screening in drastically reducing cervical cancer incidence has been clearly demonstrated. The epidemiology of cervical cancer in industrialised countries is now determined mostly by the Pap test coverage of the female population and by the ability of health systems to assure appropriate follow up after an abnormal Pap test. Today there are two fully automated systems for computer-assisted Pap test: the BD FocalPoint and the Hologic Imager. Recently, the Hologic Integrated Imager, a semi-automated system, was launched. The two fully automated systems are composed of a central scanner, where the machine examines the cytologic slide, and of one or more review stations, where the cytologists analyze the slides previously centrally scanned. The softwares used by the two systems identify the fields of interest so that the cytologists can look only at those points, automatically pointed out by the review station. Furthermore, the FocalPoint system classifies the slides according to their level of risk of containing signs of relevant lesions. Those in the upper classes--about one fifth of the slides--are labelled as « further review », while those in the lower level of risk, i.e. slides that have such a low level of risk that they can be considered as negative with no human review, are labelled as « no further review ». The aim of computer-assisted Pap test is to reduce the time of slide examination and to increase productivity. Furthermore, the number of errors due to lack of attention may decrease. Both the systems can be applied to liquidbased cytology, while only the BD Focal Point can be used on conventional smears. Cytology screening has some critical points: there is a shortage of cytologists/cytotechnicians; the quality strongly depends on the experience and ability of the cytologist; there is a subjective component in the cytological diagnosis; in highly screened populations, the prevalence of lesions is very low and the activity of cytologists is very monotonous. On the other hand, a progressive shift to molecular screening using HPV-DNA test as primary screening test is very likely in the near future; cytology will be used as triage test, dramatically reducing the number of slides to process and increasing the prevalence of lesions in those Pap tests. In this Report we assume that the diagnostic accuracy of computer-assisted Pap test is equal to the accuracy of manual Pap test and, consequently, that screening using computer-assisted Pap test has the same efficacy in reducing cervical cancer incidence and mortality. Under this assumption, the effectiveness/ benefit/utility is the same for the two screening modes, i.e. the economic analysis will be a cost minimization study. Furthermore, the screening process is identical for the two modalities in all the phases except for slide interpretation. The cost minimization analysis will be limited to the only phase differing between the two modes, i.e. the study will be a differential cost analysis between a labour-intensive strategy (traditional Pap test) and a technology-intensive strategy (the computer-assisted Pap test). Briefly, the objectives of this HTA Report are: to determine the break even point of computer-assisted Pap test systems, i.e. the volume of slides processed per year at which putting in place a computer-assisted Pap test system becomes economically convenient; to quantify the cost per Pap test in different scenarios according to screening centre activity volume, productivity of cytologist, type of cytology (conventional smear or liquid-based, fully automated or semi-automated computer-assisted); to analyse the computer-assisted Pap test in the Italian context, through a survey of the centres using the technology, collecting data useful for the sensitivity analysis of the economic evaluation; to evaluate the acceptability of the technology in the screening services; to evaluate the organizational and financial impact of the computer-assisted Pap test in different scenarios; to illustrate the ideal organization to implement computer-assisted Pap test in terms of volume of activity, productivity, and human and technological resources. to produce this Report, the following process was adopted: application to the Ministry of health for a grant « Analysis of the impact of professional involvement in evidence generation for the HTA process »; within this project, the sub-project « Cost effectiveness evaluation of the computer-assisted Pap test in the Italian screening programmes » was financed; constitution of the Working Group, which included the project coordinator, the principal investigator, and the health economist; identification of the centres using the computer-assisted Pap test and which had published scientific reports on the subject; identification of the Consulting Committee (stakeholder), which included screening programmes managers, pathologists, economists, health policy-makers, citizen organizations, and manufacturers. Once the evaluation was concluded, a plenary meeting with Working Group and Consulting Committee was held. The working group drafted the final version of this Report, which took into account the comments received. the fully automated computer-assisted Pap test has an important financial and organizational impact on screening programmes. The assessment of this health technology reached the following conclusions: according to the survey results, after some distrust, cytologists accepted the use of the machine and appreciated the reduction in interpretation time and the reliability in identifying the fields of interest; from an economic point of view, the automated computer-assisted Pap test can be convenient only with conventional smears if the screening centre has a volume of more than 49,000 slides/year and the cytologist productivity increases about threefold. It must be highlighted that it is not sufficient to adopt the automated Pap test to reach such an increase in productivity; the laboratory must be organised or re-organised to optimise the use of the review stations and the person time. In the case of liquid-based cytology, the adoption of automated computer- assisted Pap test can only increase the costs. In fact, liquid-based cytology increases the cost of consumable materials but reduces the interpretation time, even in manual screening. Consequently, the reduction of human costs is smaller in the case of computer-assisted screening. Liquid-based cytology has other implications and advantages not linked to the use of computer-assisted Pap test that should be taken into account and are beyond the scope of this Report; given that the computer-assisted Pap test reduces human costs, it may be more advantageous where the cost of cytologists is higher; given the relatively small volume of activity of screening centres in Italy, computer-assisted Pap test may be reasonable for a network using only one central scanner and several remote review stations; the use of automated computer-assisted Pap test only for quality control in a single centre is not economically sustainable. In this case as well, several centres, for example at the regional level, may form a consortium to reach a reasonable number of slides to achieve the break even point. Regarding the use of a machine rather than human intelligence to interpret the slides, some ethical issues were initially raised, but both the scientific community and healthcare professionals have accepted this technology. The identification of fields of interest by the machine is highly reproducible, reducing subjectivity in the diagnostic process. The Hologic system always includes a check by the human eye, while the FocalPoint system identifies about one fifth of the slides as No Further Review. Several studies, some of which conducted in Italy, confirmed the reliability of this classification. There is still some resistance to accept the practice of No Further Review. A check of previous slides and clinical data can be useful to make the cytologist and the clinician more confident. Computer-assisted automated Pap test may be introduced only if there is a need to increase the volume of slides screened to cover the screening target population and sufficient human resources are not available. Switching a programme using conventional slides to automatic scanning can only lead to a reduction in costs if the volume of slides per year exceeds 49,000 slides/annum and cytologist productivity is optimised to more than 20,000 slides per year. At a productivity of 15,000 or fewer, the automated computer-assisted Pap test cannot be convenient. Switching from manual screening with conventional slides to automatic scanning with liquid-based cytology cannot generate any economic saving, but the system could increase output with a given number of staff. The transition from manual to computer assisted automated screening of liquid based cytology will not generate savings and the increase in productivity will be lower than that of the switch from manual/conventional to automated/conventional. The use of biologists or pathologists as cytologists is more costly than the use of cytoscreeners. Given that the automated computer-assisted Pap test reduces human resource costs, its adoption in a model using only biologists and pathologists for screening is more economically advantageous. (ABSTRACT TRUNCATED)
Orientation/Time Management Skill Training Lesson: Development and Evaluation. Final Report.
ERIC Educational Resources Information Center
Dobrovolny, Jacqueline L.; And Others
A lesson was developed containing materials designed to assist students in their adaptation to the novelties of a computer assisted or managed instructional environment, providing students with appropriate role models for increasing acceptance of their increased responsibility for learning and introducing a progress tracking approach to assist…
NASA Astrophysics Data System (ADS)
Wang, Li-Qun; Saito, Masao
We used 1.5T functional magnetic resonance imaging (fMRI) to explore that which brain areas contribute uniquely to numeric computation. The BOLD effect activation pattern of metal arithmetic task (successive subtraction: actual calculation task) was compared with multiplication tables repetition task (rote verbal arithmetic memory task) response. The activation found in right parietal lobule during metal arithmetic task suggested that quantitative cognition or numeric computation may need the assistance of sensuous convert, such as spatial imagination and spatial sensuous convert. In addition, this mechanism may be an ’analog algorithm’ in the simple mental arithmetic processing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wampler, William R.; Myers, Samuel M.; Modine, Normand A.
2017-09-01
The energy-dependent probability density of tunneled carrier states for arbitrarily specified longitudinal potential-energy profiles in planar bipolar devices is numerically computed using the scattering method. Results agree accurately with a previous treatment based on solution of the localized eigenvalue problem, where computation times are much greater. These developments enable quantitative treatment of tunneling-assisted recombination in irradiated heterojunction bipolar transistors, where band offsets may enhance the tunneling effect by orders of magnitude. The calculations also reveal the density of non-tunneled carrier states in spatially varying potentials, and thereby test the common approximation of uniform- bulk values for such densities.
. energy system through quantitative analysis methods. Research Interests Evaluating the system and , Washington, DC (2014-2017) Postdoctoral Research Fellow, Carnegie Institution for Science, Washington, DC (2012-2014) Graduate Research and Teaching Assistant, California Institute of Technology, Pasadena, CA
Kish, Gary; Cook, Samuel A; Kis, Gréta
2013-01-01
The University of Debrecen's Faculty of Medicine has an international, multilingual student population with anatomy courses taught in English to all but Hungarian students. An elective computer-assisted gross anatomy course, the Computer Human Anatomy (CHA), has been taught in English at the Anatomy Department since 2008. This course focuses on an introduction to anatomical digital images along with clinical cases. This low-budget course has a large visual component using images from magnetic resonance imaging and computer axial tomogram scans, ultrasound clinical studies, and readily available anatomy software that presents topics which run in parallel to the university's core anatomy curriculum. From the combined computer images and CHA lecture information, students are asked to solve computer-based clinical anatomy problems in the CHA computer laboratory. A statistical comparison was undertaken of core anatomy oral examination performances of English program first-year medical students who took the elective CHA course and those who did not in the three academic years 2007-2008, 2008-2009, and 2009-2010. The results of this study indicate that the CHA-enrolled students improved their performance on required anatomy core curriculum oral examinations (P < 0.001), suggesting that computer-assisted learning may play an active role in anatomy curriculum improvement. These preliminary results have prompted ongoing evaluation of what specific aspects of CHA are valuable and which students benefit from computer-assisted learning in a multilingual and diverse cultural environment. Copyright © 2012 American Association of Anatomists.
The Software Line-up: What Reviewers Look for When Evaluating Software.
ERIC Educational Resources Information Center
ELECTRONIC Learning, 1982
1982-01-01
Contains a check list to aid teachers in evaluating software used in computer-assisted instruction on microcomputers. The evaluation form contains three sections: program description, program evaluation, and overall evaluation. A brief description of a software evaluation program in use at the Granite School District in Utah is included. (JJD)
Liang, Weiqiang; Yao, Yuanyuan; Huang, Zixian; Chen, Yuhong; Ji, Chenyang; Zhang, Jinming
2016-07-01
The purpose of this study was to evaluate the clinical application of individual craniofacial bone fabrications using computer-assisted design (CAD)-computer-assisted manufacturing technology for the reconstruction of craniofacial bone defects. A total of 8 patients diagnosed with craniofacial bone defects were enrolled in this study between May 2007 and August 2010. After computed tomography scans were obtained, the patients were fitted with artificial bone that was created using CAD software, rapid prototyping technology, and epoxy-methyl acrylate resin and hydroxyapatite materials. The fabrication was fixed to the defect area with titanium screws, and soft tissue defects were repaired if necessary. The fabrications were precisely fixed to the defect areas, and all wounds healed well without any serious complications except for 1 case with intraoral incision dehiscence, which required further treatment. Postoperative curative effects were retrospectively observed after 6 to 48 months, acceptable anatomic and cosmetic outcomes were obtained, and no rejections or other complications occurred. The use of CAD-computer-assisted manufacturing technology-assisted epoxy-methyl acrylate resin and hydroxyapatite composite artificial bone to treat patients with craniofacial bone defects could enable the precise reconstruction of these defects and obtain good anatomic and cosmetic outcomes. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Mautone, Jennifer A; DuPaul, George J; Jitendra, Asha K
2005-08-01
The present study examines the effects of computer-assisted instruction (CAI) on the mathematics performance and classroom behavior of three second-through fourth-grade students with ADHD. A controlled case study is used to evaluate the effects of the computer software on participants' mathematics performance and on-task behavior. Participants' mathematics achievement improve and their on-task behavior increase during the CAI sessions relative to independent seatwork conditions. In addition, students and teachers consider CAI to be an acceptable intervention for some students with ADHD who are having difficulty with mathematics. Implications of these results for practice and research are discussed.
The computer in office medical practice.
Dowdle, John
2002-04-01
There will continue to be change and evolution in the medical office environment. As voice recognition systems continue to improve, instant creation of office notes with the absence of dictation may be commonplace. As medical and computer technology evolves, we must continue to evaluate the many new computer systems that can assist us in our clinical office practice.
Kolanjiyil, Arun V; Kleinstreuer, Clement
2016-12-01
Computational predictions of aerosol transport and deposition in the human respiratory tract can assist in evaluating detrimental or therapeutic health effects when inhaling toxic particles or administering drugs. However, the sheer complexity of the human lung, featuring a total of 16 million tubular airways, prohibits detailed computer simulations of the fluid-particle dynamics for the entire respiratory system. Thus, in order to obtain useful and efficient particle deposition results, an alternative modeling approach is necessary where the whole-lung geometry is approximated and physiological boundary conditions are implemented to simulate breathing. In Part I, the present new whole-lung-airway model (WLAM) represents the actual lung geometry via a basic 3-D mouth-to-trachea configuration while all subsequent airways are lumped together, i.e., reduced to an exponentially expanding 1-D conduit. The diameter for each generation of the 1-D extension can be obtained on a subject-specific basis from the calculated total volume which represents each generation of the individual. The alveolar volume was added based on the approximate number of alveoli per generation. A wall-displacement boundary condition was applied at the bottom surface of the first-generation WLAM, so that any breathing pattern due to the negative alveolar pressure can be reproduced. Specifically, different inhalation/exhalation scenarios (rest, exercise, etc.) were implemented by controlling the wall/mesh displacements to simulate realistic breathing cycles in the WLAM. Total and regional particle deposition results agree with experimental lung deposition results. The outcomes provide critical insight to and quantitative results of aerosol deposition in human whole-lung airways with modest computational resources. Hence, the WLAM can be used in analyzing human exposure to toxic particulate matter or it can assist in estimating pharmacological effects of administered drug-aerosols. As a practical WLAM application, the transport and deposition of asthma drugs from a commercial dry-powder inhaler is discussed in Part II. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evaluative methodology for prioritizing transportation energy conservation strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pang, L.M.G.
An analytical methodology was developed for the purpose of prioritizing a set of transportation energy conservation (TEC) strategies within an urban environment. Steps involved in applying the methodology consist of 1) defining the goals, objectives and constraints of the given urban community, 2) identifying potential TEC strategies, 3) assessing the impact of the strategies, 4) applying the TEC evaluation model, and 5) utilizing a selection process to determine the optimal set of strategies for implementation. This research provides an overview of 21 TEC strategies, a quick-response technique for estimating energy savings, a multiattribute utility theory approach for assessing subjective impacts,more » and a computer program for making the strategy evaluations, all of which assist in expediting the execution of the entire methodology procedure. The critical element of the methodology is the strategy evaluation model which incorporates a number of desirable concepts including 1) a comprehensive accounting of all relevant impacts, 2) the application of multiobjective decision-making techniques, 3) an approach to assure compatibilty among quantitative and qualitative impact measures, 4) the inclusion of the decision maker's preferences in the evaluation procedure, and 5) the cost-effectiveness concept. Application of the methodolgy to Salt Lake City, Utah demonstrated its utility, ease of use and favorability by decision makers.« less
EVALUE : a computer program for evaluating investments in forest products industries
Peter J. Ince; Philip H. Steele
1980-01-01
EVALUE, a FORTRAN program, was developed to provide a framework for cash flow analysis of investment opportunities. EVALUE was designed to assist researchers in evaluating investment feasibility of new technology or new manufacturing processes. This report serves as user documentation for the EVALUE program. EVALUE is briefly described and notes on preparation of a...
Using and Evaluating Resampling Simulations in SPSS and Excel.
ERIC Educational Resources Information Center
Smith, Brad
2003-01-01
Describes and evaluates three computer-assisted simulations used with Statistical Package for the Social Sciences (SPSS) and Microsoft Excel. Designed the simulations to reinforce and enhance student understanding of sampling distributions, confidence intervals, and significance tests. Reports evaluations revealed improved student comprehension of…
Galli, M; Cimolin, V; De Pandis, M F; Le Pera, D; Sova, I; Albertini, G; Stocchi, F; Franceschini, M
2016-01-01
The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson's disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD.
Stefan, Melanie I.; Gutlerner, Johanna L.; Born, Richard T.; Springer, Michael
2015-01-01
The past decade has seen a rapid increase in the ability of biologists to collect large amounts of data. It is therefore vital that research biologists acquire the necessary skills during their training to visualize, analyze, and interpret such data. To begin to meet this need, we have developed a “boot camp” in quantitative methods for biology graduate students at Harvard Medical School. The goal of this short, intensive course is to enable students to use computational tools to visualize and analyze data, to strengthen their computational thinking skills, and to simulate and thus extend their intuition about the behavior of complex biological systems. The boot camp teaches basic programming using biological examples from statistics, image processing, and data analysis. This integrative approach to teaching programming and quantitative reasoning motivates students’ engagement by demonstrating the relevance of these skills to their work in life science laboratories. Students also have the opportunity to analyze their own data or explore a topic of interest in more detail. The class is taught with a mixture of short lectures, Socratic discussion, and in-class exercises. Students spend approximately 40% of their class time working through both short and long problems. A high instructor-to-student ratio allows students to get assistance or additional challenges when needed, thus enhancing the experience for students at all levels of mastery. Data collected from end-of-course surveys from the last five offerings of the course (between 2012 and 2014) show that students report high learning gains and feel that the course prepares them for solving quantitative and computational problems they will encounter in their research. We outline our course here which, together with the course materials freely available online under a Creative Commons License, should help to facilitate similar efforts by others. PMID:25880064
Stefan, Melanie I; Gutlerner, Johanna L; Born, Richard T; Springer, Michael
2015-04-01
The past decade has seen a rapid increase in the ability of biologists to collect large amounts of data. It is therefore vital that research biologists acquire the necessary skills during their training to visualize, analyze, and interpret such data. To begin to meet this need, we have developed a "boot camp" in quantitative methods for biology graduate students at Harvard Medical School. The goal of this short, intensive course is to enable students to use computational tools to visualize and analyze data, to strengthen their computational thinking skills, and to simulate and thus extend their intuition about the behavior of complex biological systems. The boot camp teaches basic programming using biological examples from statistics, image processing, and data analysis. This integrative approach to teaching programming and quantitative reasoning motivates students' engagement by demonstrating the relevance of these skills to their work in life science laboratories. Students also have the opportunity to analyze their own data or explore a topic of interest in more detail. The class is taught with a mixture of short lectures, Socratic discussion, and in-class exercises. Students spend approximately 40% of their class time working through both short and long problems. A high instructor-to-student ratio allows students to get assistance or additional challenges when needed, thus enhancing the experience for students at all levels of mastery. Data collected from end-of-course surveys from the last five offerings of the course (between 2012 and 2014) show that students report high learning gains and feel that the course prepares them for solving quantitative and computational problems they will encounter in their research. We outline our course here which, together with the course materials freely available online under a Creative Commons License, should help to facilitate similar efforts by others.
Quantitative Evaluation of Musical Scale Tunings
ERIC Educational Resources Information Center
Hall, Donald E.
1974-01-01
The acoustical and mathematical basis of the problem of tuning the twelve-tone chromatic scale is reviewed. A quantitative measurement showing how well any tuning succeeds in providing just intonation for any specific piece of music is explained and applied to musical examples using a simple computer program. (DT)
Borgestig, Maria; Falkmer, Torbjörn; Hemmingsson, Helena
2013-11-01
The aim of this study was to evaluate the effect of an assistive technology (AT) intervention to improve the use of available computers as assistive technology in educational tasks for students with physical disabilities during an ongoing school year. Fifteen students (aged 12-18) with physical disabilities, included in mainstream classrooms in Sweden, and their teachers took part in the intervention. Pre-, post-, and follow-up data were collected with Goal Attainment Scaling (GAS), a computer usage diary, and with the Psychosocial Impact of Assistive Devices Scale (PIADS). Teachers' opinions of goal setting were collected at follow-up. The intervention improved the goal-related computer usage in educational tasks and teachers reported they would use goal setting again when appropriate. At baseline, students reported a positive impact from computer usage with no differences over time regarding the PIADS subscales independence, adaptability, or self-esteem. The AT intervention showed a positive effect on computer usage as AT in mainstream schools. Some additional support to teachers is recommended as not all students improved in all goal-related computer usage. A clinical implication is that students' computer usage can be improved and collaboratively established computer-based strategies can be carried out by teachers in mainstream schools.
Composing, Analyzing and Validating Software Models
NASA Astrophysics Data System (ADS)
Sheldon, Frederick T.
1998-10-01
This research has been conducted at the Computational Sciences Division of the Information Sciences Directorate at Ames Research Center (Automated Software Engineering Grp). The principle work this summer has been to review and refine the agenda that were carried forward from last summer. Formal specifications provide good support for designing a functionally correct system, however they are weak at incorporating non-functional performance requirements (like reliability). Techniques which utilize stochastic Petri nets (SPNs) are good for evaluating the performance and reliability for a system, but they may be too abstract and cumbersome from the stand point of specifying and evaluating functional behavior. Therefore, one major objective of this research is to provide an integrated approach to assist the user in specifying both functionality (qualitative: mutual exclusion and synchronization) and performance requirements (quantitative: reliability and execution deadlines). In this way, the merits of a powerful modeling technique for performability analysis (using SPNs) can be combined with a well-defined formal specification language. In doing so, we can come closer to providing a formal approach to designing a functionally correct system that meets reliability and performance goals.
Ocular Signs Related to Overweight and Arterial Hypertension in Children: A Systematic Review
Schuh, Daniela S.; Piccoli, Ângela B.; Paiani, Raquel L.; Maciel, Cristiane R; Pellanda, Lucia C; Vilela, Manuel AP
2017-01-01
Background: The ocular effects of obesity and hypertension need to be established and can be used as prognostic markers. Objective: To estimate the prevalence of ophthalmological alterations in children and adolescents who are overweight and/or have SAH. Methods: The database for this study included all observational studies (CS, cohort, case-control and “baseline” description of randomized clinical trials) with children and/or adolescents who were overweight, obese or had SAH and that measured ophthalmological alterations. Results: Comparative studies with healthy children demonstrated positive association between body adiposity with retinal venular dilation, and SAH with retinal arteriolar narrowing. Different retinal fundus cameras and computer-assisted programs to evaluate the retinal vessels, variations in the methods of analysis, adjustments, populations, were the main arguments against formal meta-analysis. The heterogeneity was too high (I2 >90%, in fixed or randomized effects), and the lack of linearity, normal distribution and homoscedasticity did not recommend meta-regression. Conclusion: Obesity and SAH show associations with ophthalmological alterations, especially with retinal vessel diameter. Lack of standardization does not allow a quantitative evaluation. PMID:29081867
Composing, Analyzing and Validating Software Models
NASA Technical Reports Server (NTRS)
Sheldon, Frederick T.
1998-01-01
This research has been conducted at the Computational Sciences Division of the Information Sciences Directorate at Ames Research Center (Automated Software Engineering Grp). The principle work this summer has been to review and refine the agenda that were carried forward from last summer. Formal specifications provide good support for designing a functionally correct system, however they are weak at incorporating non-functional performance requirements (like reliability). Techniques which utilize stochastic Petri nets (SPNs) are good for evaluating the performance and reliability for a system, but they may be too abstract and cumbersome from the stand point of specifying and evaluating functional behavior. Therefore, one major objective of this research is to provide an integrated approach to assist the user in specifying both functionality (qualitative: mutual exclusion and synchronization) and performance requirements (quantitative: reliability and execution deadlines). In this way, the merits of a powerful modeling technique for performability analysis (using SPNs) can be combined with a well-defined formal specification language. In doing so, we can come closer to providing a formal approach to designing a functionally correct system that meets reliability and performance goals.
Policy of Labor Management and Health Education: a ProgeSUS experience.
Magnago, Carinne; Pierantoni, Celia Regina; França, Tania; Vieira, Swheelen de Paula; Miranda, Rômulo Gonçalves de; Nascimento, Dayane Nunes
2017-05-01
To evaluate the stage of labor management and education policies in municipal and state health secretariats (SMS and SES, respectively), having as reference the adherence to a qualification and structuring program of work management and education in the Unified Health System. A descriptive and quantitative study, developed with 519 representatives from the Human Resources (HR) area of SMS and SES, through a survey composed of 56 questions, via a computer-assisted telephone interview in 2012. Responses were processed in a computerized database and the data treated by descriptive statistics. Changes in professional qualification, the establishment of job and salary plans and negotiation processes were identified; on the other hand, there was no progress related to the financial and budgetary autonomy of the area of work management and health education. It is observed progress in the incorporation of innovations in the management in SES and SMS from the process of training of managers and financial induction. It is necessary to monitor and periodically evaluate the operationalization of labor and education policies aimed at strengthening them, correcting directions and implementing innovative actions.
Computer-assisted segmentation of white matter lesions in 3D MR images using support vector machine.
Lao, Zhiqiang; Shen, Dinggang; Liu, Dengfeng; Jawad, Abbas F; Melhem, Elias R; Launer, Lenore J; Bryan, R Nick; Davatzikos, Christos
2008-03-01
Brain lesions, especially white matter lesions (WMLs), are associated with cardiac and vascular disease, but also with normal aging. Quantitative analysis of WML in large clinical trials is becoming more and more important. In this article, we present a computer-assisted WML segmentation method, based on local features extracted from multiparametric magnetic resonance imaging (MRI) sequences (ie, T1-weighted, T2-weighted, proton density-weighted, and fluid attenuation inversion recovery MRI scans). A support vector machine classifier is first trained on expert-defined WMLs, and is then used to classify new scans. Postprocessing analysis further reduces false positives by using anatomic knowledge and measures of distance from the training set. Cross-validation on a population of 35 patients from three different imaging sites with WMLs of varying sizes, shapes, and locations tests the robustness and accuracy of the proposed segmentation method, compared with the manual segmentation results from two experienced neuroradiologists.
Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; China, Toshiyuki; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Horie, Shigeo
2015-05-01
To evaluate the feasibility and accuracy of virtual partial nephrectomy analysis, including a color-coded three-dimensional virtual surgical planning and a quantitative functional analysis, in predicting the surgical outcomes of robot-assisted partial nephrectomy. Between 2012 and 2014, 20 patients underwent virtual partial nephrectomy analysis before undergoing robot-assisted partial nephrectomy. Virtual partial nephrectomy analysis was carried out with the following steps: (i) evaluation of the arterial branch for selective clamping by showing the vascular-supplied area; (ii) simulation of the optimal surgical margin in precise segmented three-dimensional model for prediction of collecting system opening; and (iii) detailed volumetric analyses and estimates of postoperative renal function based on volumetric change. At operation, the surgeon identified the targeted artery and determined the surgical margin according to the virtual partial nephrectomy analysis. The surgical outcomes between the virtual partial nephrectomy analysis and the actual robot-assisted partial nephrectomy were compared. All 20 patients had negative cancer surgical margins and no urological complications. The tumor-specific renal arterial supply areas were shown in color-coded three-dimensional model visualization in all cases. The prediction value of collecting system opening was 85.7% for sensitivity and 100% for specificity. The predicted renal resection volume was significantly correlated with actual resected specimen volume (r(2) = 0.745, P < 0.001). The predicted estimated glomerular filtration rate was significantly correlated with actual postoperative estimated glomerular filtration rate (r(2) = 0.736, P < 0.001). Virtual partial nephrectomy analysis is able to provide the identification of tumor-specific renal arterial supply, prediction of collecting system opening and prediction of postoperative renal function. This technique might allow urologists to compare various arterial clamping methods and resection margins with surgical outcomes in a non-invasive manner. © 2015 The Japanese Urological Association.
Gøthesen, Øystein; Slover, James; Havelin, Leif; Askildsen, Jan Erik; Malchau, Henrik; Furnes, Ove
2013-07-06
The use of Computer Assisted Surgery (CAS) for knee replacements is intended to improve the alignment of knee prostheses in order to reduce the number of revision operations. Is the cost effectiveness of computer assisted surgery influenced by patient volume and age? By employing a Markov model, we analysed the cost effectiveness of computer assisted surgery versus conventional arthroplasty with respect to implant survival and operation volume in two theoretical Norwegian age cohorts. We obtained mortality and hospital cost data over a 20-year period from Norwegian registers. We presumed that the cost of an intervention would need to be below NOK 500,000 per QALY (Quality Adjusted Life Year) gained, to be considered cost effective. The added cost of computer assisted surgery, provided this has no impact on implant survival, is NOK 1037 and NOK 1414 respectively for 60 and 75-year-olds per quality-adjusted life year at a volume of 25 prostheses per year, and NOK 128 and NOK 175 respectively at a volume of 250 prostheses per year. Sensitivity analyses showed that the 10-year implant survival in cohort 1 needs to rise from 89.8% to 90.6% at 25 prostheses per year, and from 89.8 to 89.9% at 250 prostheses per year for computer assisted surgery to be considered cost effective. In cohort 2, the required improvement is a rise from 95.1% to 95.4% at 25 prostheses per year, and from 95.10% to 95.14% at 250 prostheses per year. The cost of using computer navigation for total knee replacements may be acceptable for 60-year-old as well as 75-year-old patients if the technique increases the implant survival rate just marginally, and the department has a high operation volume. A low volume department might not achieve cost-effectiveness unless computer navigation has a more significant impact on implant survival, thus may defer the investments until such data are available.
A Comparison of Four Simulation and Instructional Methods for Endodontic Review.
ERIC Educational Resources Information Center
Sandoval, Victor A.; And Others
1987-01-01
The effects of four different endodontic self-instructional review formats (slide-tape, latent-image simulation, computer text simulation, and computer-assisted video interactive simulation) on senior clinical endodontic performance are compared. Student evaluations, as well as comparative developmental expenditures, are discussed. (Author/MLW)
Creating a Minnesota Statewide SNAP-Ed Program Evaluation
ERIC Educational Resources Information Center
Gold, Abby; Barno, Trina Adler; Sherman, Shelley; Lovett, Kathleen; Hurtado, G. Ali
2013-01-01
Systematic evaluation is an essential tool for understanding program effectiveness. This article describes the pilot test of a statewide evaluation tool for the Supplemental Nutrition Assistance Program-Education (SNAP-Ed). A computer algorithm helped Community Nutrition Educators (CNEs) build surveys specific to their varied educational settings…
Serials Evaluation: An Innovative Approach.
ERIC Educational Resources Information Center
Berger, Marilyn; Devine, Jane
1990-01-01
Describes a method of analyzing serials collections in special libraries that combines evaluative criteria with database management technology. Choice of computer software is discussed, qualitative information used to evaluate subject coverage is examined, and quantitative and descriptive data that can be used for collection management are…
Virtualising the Quantitative Research Methods Course: An Island-Based Approach
ERIC Educational Resources Information Center
Baglin, James; Reece, John; Baker, Jenalle
2015-01-01
Many recent improvements in pedagogical practice have been enabled by the rapid development of innovative technologies, particularly for teaching quantitative research methods and statistics. This study describes the design, implementation, and evaluation of a series of specialised computer laboratory sessions. The sessions combined the use of an…
CAD system for automatic analysis of CT perfusion maps
NASA Astrophysics Data System (ADS)
Hachaj, T.; Ogiela, M. R.
2011-03-01
In this article, authors present novel algorithms developed for the computer-assisted diagnosis (CAD) system for analysis of dynamic brain perfusion, computer tomography (CT) maps, cerebral blood flow (CBF), and cerebral blood volume (CBV). Those methods perform both quantitative analysis [detection and measurement and description with brain anatomy atlas (AA) of potential asymmetries/lesions] and qualitative analysis (semantic interpretation of visualized symptoms). The semantic interpretation (decision about type of lesion: ischemic/hemorrhagic, is the brain tissue at risk of infraction or not) of visualized symptoms is done by, so-called, cognitive inference processes allowing for reasoning on character of pathological regions based on specialist image knowledge. The whole system is implemented in.NET platform (C# programming language) and can be used on any standard PC computer with.NET framework installed.
One Small Step for Manuals: Computer-Assisted Training in Twelve-Step Facilitation*
Sholomskas, Diane E.; Carroll, Kathleen M.
2008-01-01
Objective The burgeoning number of empirically validated therapies has not been met with systematic evaluation of practical, inexpensive means of teaching large numbers of clinicians to use these treatments effectively. An interactive, computer-assisted training program that sought to impart skills associated with the Project MATCH (Matching Alcoholism Treatments to Client Heterogeneity) Twelve-Step Facilitation (TSF) manual was developed to address this need. Method Twenty-five community-based substance use-treatment clinicians were randomized to one of two training conditions: (1) access to the computer-assisted training program plus the TSF manual or (2) access to the manual only. The primary outcome measure was change from pre- to posttraining in the clinicians' ability to demonstrate key TSF skills. Results The data suggested that the clinicians' ability to implement TSF, as assessed by independent ratings of adherence and skill for the key TSF interventions, was significantly higher after training for those who had access to the computerized training condition than those who were assigned to the manual-only condition. Those assigned to the computer-assisted training condition also demonstrated greater gains in a knowledge test assessing familiarity with concepts presented in the TSF manual. Conclusions Computer-based training may be a feasible and effective means of training larger numbers of clinicians in empirically supported, manual-guided therapies. PMID:17061013
One small step for manuals: Computer-assisted training in twelve-step facilitation.
Sholomskas, Diane E; Carroll, Kathleen M
2006-11-01
The burgeoning number of empirically validated therapies has not been met with systematic evaluation of practical, inexpensive means of teaching large numbers of clinicians to use these treatments effectively. An interactive, computer-assisted training program that sought to impart skills associated with the Project MATCH (Matching Alcoholism Treatments to Client Heterogeneity) Twelve-Step Facilitation (TSF) manual was developed to address this need. Twenty-five community-based substance use-treatment clinicians were randomized to one of two training conditions: (1) access to the computer- assisted training program plus the TSF manual or (2) access to the manual only. The primary outcome measure was change from preto posttraining in the clinicians' ability to demonstrate key TSF skills. The data suggested that the clinicians' ability to implement TSF, as assessed by independent ratings of adherence and skill for the key TSF interventions, was significantly higher after training for those who had access to the computerized training condition than those who were assigned to the manual-only condition. Those assigned to the computer-assisted training condition also demonstrated greater gains in a knowledge test assessing familiarity with concepts presented in the TSF manual. Computer-based training may be a feasible and effective means of training larger numbers of clinicians in empirically supported, manual-guided therapies.
Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook
2014-01-01
Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data. PMID:25225874
Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook
2014-09-15
Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data.
A Computer-Assisted Personalized Approach in an Undergraduate Plant Physiology Class1
Artus, Nancy N.; Nadler, Kenneth D.
1999-01-01
We used Computer-Assisted Personalized Approach (CAPA), a networked teaching and learning tool that generates computer individualized homework problem sets, in our large-enrollment introductory plant physiology course. We saw significant improvement in student examination performance with regular homework assignments, with CAPA being an effective and efficient substitute for hand-graded homework. Using CAPA, each student received a printed set of similar but individualized problems of a conceptual (qualitative) and/or quantitative nature with quality graphics. Because each set of problems is unique, students were encouraged to work together to clarify concepts but were required to do their own work for credit. Students could enter answers multiple times without penalty, and they were able to obtain immediate feedback and hints until the due date. These features increased student time on task, allowing higher course standards and student achievement in a diverse student population. CAPA handles routine tasks such as grading, recording, summarizing, and posting grades. In anonymous surveys, students indicated an overwhelming preference for homework in CAPA format, citing several features such as immediate feedback, multiple tries, and on-line accessibility as reasons for their preference. We wrote and used more than 170 problems on 17 topics in introductory plant physiology, cataloging them in a computer library for general access. Representative problems are compared and discussed. PMID:10198076
Wu, Xinzhou; Li, Weifeng; Guo, Pengran; Zhang, Zhixiang; Xu, Hanhong
2018-04-18
Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) has been applied for rapid, sensitive, undisputed, and quantitative detection of pesticide residues on fresh leaves with little sample pretreatment. Various pesticides (insecticides, bactericides, herbicides, and acaricides) are detected directly in the complex matrix with excellent limits of detection down to 4 μg/L. FTICR-MS could unambiguously identify pesticides with tiny mass differences (∼0.017 75 Da), thereby avoiding false-positive results. Remarkably, pesticide isomers can be totally discriminated by use of diagnostic fragments, and quantitative analysis of pesticide isomers is demonstrated. The present results expand the horizons of the MALDI-FTICR-MS platform in the reliable determination of pesticides, with integrated advantages of ultrahigh mass resolution and accuracy. This method provides growing evidence for the resultant detrimental effects of pesticides, expediting the identification and evaluation of innovative pesticides.
Quantitative evaluation of low-cost frame-grabber boards for personal computers.
Kofler, J M; Gray, J E; Fuelberth, J T; Taubel, J P
1995-11-01
Nine moderately priced frame-grabber boards for both Macintosh (Apple Computers, Cupertino, CA) and IBM-compatible computers were evaluated using a Society of Motion Pictures and Television Engineers (SMPTE) pattern and a video signal generator for dynamic range, gray-scale reproducibility, and spatial integrity of the captured image. The degradation of the video information ranged from minor to severe. Some boards are of reasonable quality for applications in diagnostic imaging and education. However, price and quality are not necessarily directly related.
Zhang, Wen-Bo; Mao, Chi; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin
2015-10-01
Orbital floor defects after extensive maxillectomy can cause severe esthetic and functional deformities. Orbital floor reconstruction using the computer-assisted fabricated individual titanium mesh technique is a promising method. This study evaluated the application and clinical outcomes of this technique. This retrospective study included 10 patients with orbital floor defects after maxillectomy performed from 2012 through 2014. A 3-dimensional individual stereo model based on mirror images of the unaffected orbit was obtained to fabricate an anatomically adapted titanium mesh using computer-assisted design and manufacturing. The titanium mesh was inserted into the defect using computer navigation. The postoperative globe projection and orbital volume were measured and the incidence of postoperative complications was evaluated. The average postoperative globe projection was 15.91 ± 1.80 mm on the affected side and 16.24 ± 2.24 mm on the unaffected side (P = .505), and the average postoperative orbital volume was 26.01 ± 1.28 and 25.57 ± 1.89 mL, respectively (P = .312). The mean mesh depth was 25.11 ± 2.13 mm. The mean follow-up period was 23.4 ± 7.7 months (12 to 34 months). Of the 10 patients, 9 did not develop diplopia or a decrease in visual acuity and ocular motility. Titanium mesh exposure was not observed in any patient. All patients were satisfied with their postoperative facial symmetry. Orbital floor reconstruction after extensive maxillectomy with an individual titanium mesh fabricated using computer-assisted techniques can preserve globe projection and orbital volume, resulting in successful clinical outcomes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Culp, G. H.; And Others
Over 100 interactive computer programs for use in general and organic chemistry at the University of Texas at Austin have been prepared. The rationale for the programs is based upon the belief that computer-assisted instruction (CAI) can improve education by, among other things, freeing teachers from routine tasks, measuring entry skills,…
Three-dimensional segmentation of the tumor mass in computed tomographic images of neuroblastoma
NASA Astrophysics Data System (ADS)
Deglint, Hanford J.; Rangayyan, Rangaraj M.; Boag, Graham S.
2004-05-01
Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, fibrosis, and normal tissue are often intermixed. Rather than attempt to separate these tissue types into distinct regions, we propose to explore methods to delineate the normal structures expected in abdominal CT images, remove them from further consideration, and examine the remaining parts of the images for the tumor mass. We explore the use of fuzzy connectivity for this purpose. Expert knowledge provided by the radiologist in the form of the expected structures and their shapes, HU values, and radiological characteristics are also incorporated in the segmentation algorithm. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative assessment of the response to chemotherapy and in the planning of delayed surgery for resection of the tumor. The performance of the algorithm is evaluated using cases acquired from the Alberta Children's Hospital.
ERIC Educational Resources Information Center
Islam, Muhammad Faysal
2013-01-01
Cloud computing offers the advantage of on-demand, reliable and cost efficient computing solutions without the capital investment and management resources to build and maintain in-house data centers and network infrastructures. Scalability of cloud solutions enable consumers to upgrade or downsize their services as needed. In a cloud environment,…
Pazhur, R J; Kutter, B; Georgieff, M; Schraag, S
2003-06-01
Portable digital assistants (PDAs) may be of value to the anaesthesiologist as development in medical care is moving towards "bedside computing". Many different portable computers are currently available and it is now possible for the physician to carry a mobile computer with him all the time. It is data base, reference book, patient tracking help, date planner, computer, book, magazine, calculator and much more in one mobile device. With the help of a PDA, information that is required for our work may be available at all times and everywhere at the point of care within seconds. In this overview the possibilities for the use of PDAs in anaesthesia and intensive care medicine are discussed. Developments in other countries, possibilities in use but also problems such as data security and network technology are evaluated.
Acoustics based assessment of respiratory diseases using GMM classification.
Mayorga, P; Druzgalski, C; Morelos, R L; Gonzalez, O H; Vidales, J
2010-01-01
The focus of this paper is to present a method utilizing lung sounds for a quantitative assessment of patient health as it relates to respiratory disorders. In order to accomplish this, applicable traditional techniques within the speech processing domain were utilized to evaluate lung sounds obtained with a digital stethoscope. Traditional methods utilized in the evaluation of asthma involve auscultation and spirometry, but utilization of more sensitive electronic stethoscopes, which are currently available, and application of quantitative signal analysis methods offer opportunities of improved diagnosis. In particular we propose an acoustic evaluation methodology based on the Gaussian Mixed Models (GMM) which should assist in broader analysis, identification, and diagnosis of asthma based on the frequency domain analysis of wheezing and crackles.
Renkawitz, Tobias; Tingart, Markus; Grifka, Joachim; Sendtner, Ernst; Kalteis, Thomas
2009-09-01
This article outlines the scientific basis and a state-of-the-art application of computer-assisted orthopedic surgery in total hip arthroplasty (THA) and provides a future perspective on this technology. Computer-assisted orthopedic surgery in primary THA has the potential to couple 3D simulations with real-time evaluations of surgical performance, which has brought these developments from the research laboratory all the way to clinical use. Nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during THA. More recently, computer-assisted orthopedic surgery systems have opened a new frontier for accurate surgical practice in minimally invasive, tissue-preserving THA. The future generation of imageless navigation systems will switch from simple measurement tasks to real navigation tools. These software algorithms will consider the cup and stem as components of a coupled biomechanical system, navigating the orthopedic surgeon to find an optimized complementary component orientation rather than target values intraoperatively, and are expected to have a high impact on clinical practice and postoperative functionality in modern THA.
NASA Astrophysics Data System (ADS)
Lee, Dong Hyuk; Kim, JongHyo; Kim, Hee C.; Lee, Yong W.; Min, Byong Goo
1997-04-01
There have been a number of studies on the quantitative evaluation of diffuse liver disease by using texture analysis technique. However, the previous studies have been focused on the classification between only normal and abnormal pattern based on textural properties, resulting in lack of clinically useful information about the progressive status of liver disease. Considering our collaborative research experience with clinical experts, we judged that not only texture information but also several shape properties are necessary in order to successfully classify between various states of disease with liver ultrasonogram. Nine image parameters were selected experimentally. One of these was texture parameter and others were shape parameters measured as length, area and curvature. We have developed a neural-net algorithm that classifies liver ultrasonogram into 9 categories of liver disease: 3 main category and 3 sub-steps for each. Nine parameters were collected semi- automatically from the user by using graphical user interface tool, and then processed to give a grade for each parameter. Classifying algorithm consists of two steps. At the first step, each parameter was graded into pre-defined levels using neural network. in the next step, neural network classifier determined disease status using graded nine parameters. We implemented a PC based computer-assist diagnosis workstation and installed it in radiology department of Seoul National University Hospital. Using this workstation we collected 662 cases during 6 months. Some of these were used for training and others were used for evaluating accuracy of the developed algorithm. As a conclusion, a liver ultrasonogram classifying algorithm was developed using both texture and shape parameters and neural network classifier. Preliminary results indicate that the proposed algorithm is useful for evaluation of diffuse liver disease.
An evaluation of a solution focused computer game in adolescent interventions.
Coyle, David; Doherty, Gavin; Sharry, John
2009-07-01
Many adolescents experience difficulties with traditional face-to-face mental health care approaches. Personal Investigator (PI) is a 3D computer game specifically designed for use in adolescent interventions. The game implements a model of Solution Focused Therapy. It aims to assist in easing the difficulties experienced by adolescents with direct face-to-face approaches. In sessions a therapist and adolescent sit together at a computer and play PI. Issues raised in the game serve as a context for more detailed discussions between the therapist and client. This article describes a study in which PI was used with 22 adolescent clients, attending mental health care services due to a variety of difficulties. Whilst further trials are required, results indicate positive benefits of using PI. PI can help in building an effective client-therapist relationship, can assist in structuring sessions, and can assist in improving client engagement in the therapeutic process.
DOT National Transportation Integrated Search
2013-08-01
This research aimed to evaluate the data requirements for computer assisted construction planning : and staging methods that can be implemented in pavement rehabilitation projects in the state of : Georgia. Results showed that two main issues for the...
Evaluation of a Computer Assisted Instruction Resource in Nursing Education.
ERIC Educational Resources Information Center
Herriot, Anne M.; Bishop, Jacki A.; Kelly, Mary; Murphy, Margaret; Truby, Helen
2003-01-01
Nine second-year and six final-year nursing students completed a questionnaire and participated in focus groups about STEP-DIET, a computer-based dietetics instructional tool. Students liked the design and content, perceived increased nutritional knowledge and understanding of dietitians' role. However, they were reluctant to accept…
Macromod: Computer Simulation For Introductory Economics
ERIC Educational Resources Information Center
Ross, Thomas
1977-01-01
The Macroeconomic model (Macromod) is a computer assisted instruction simulation model designed for introductory economics courses. An evaluation of its utilization at a community college indicates that it yielded a 10 percent to 13 percent greater economic comprehension than lecture classes and that it met with high student approval. (DC)
Improving Mathematics Learning of Kindergarten Students through Computer-Assisted Instruction
ERIC Educational Resources Information Center
Foster, Matthew E.; Anthony, Jason L.; Clements, Doug H.; Sarama, Julie; Williams, Jeffrey M.
2016-01-01
This study evaluated the effects of a mathematics software program, the Building Blocks software suite, on young children's mathematics performance. Participants included 247 Kindergartners from 37 classrooms in 9 schools located in low-income communities. Children within classrooms were randomly assigned to receive 21 weeks of computer-assisted…
In Vitro Evaluation of a Program for Machine-Aided Indexing.
ERIC Educational Resources Information Center
Jacquemin, Christian; Daille, Beatrice; Royaute, Jean; Polanco, Xavier
2002-01-01
Presents the human evaluation of ILIAD, a program for machine-aided indexing that was designed to assist expert librarians in computer-aided indexing and document analysis. Topics include controlled indexing and free indexing; natural language and concept-based information retrieval; evaluation methodology; syntactic variations; and a comparison…
From vagueness in medical thought to the foundations of fuzzy reasoning in medical diagnosis.
Seising, Rudolf
2006-11-01
This article delineates a relatively unknown path in the history of medical philosophy and medical diagnosis. It is concerned with the phenomenon of vagueness in the physician's "style of thinking" and with the use of fuzzy sets, systems, and relations with a view to create a model of such reasoning when physicians make a diagnosis. It represents specific features of medical ways of thinking that were mentioned by the Polish physician and philosopher Ludwik Fleck in 1926. The paper links Lotfi Zadeh's work on system theory before the age of fuzzy sets with system-theory concepts in medical philosophy that were introduced by the philosopher Mario Bunge, and with the fuzzy-theoretical analysis of the notions of health, illness, and disease by the Iranian-German physician and philosopher Kazem Sadegh-Zadeh. Some proposals to apply fuzzy sets in medicine were based on a suggestion made by Zadeh: symptoms and diseases are fuzzy in nature and fuzzy sets are feasible to represent these entity classes of medical knowledge. Yet other attempts to use fuzzy sets in medicine were self-contained. The use of this approach contributed to medical decision-making and the development of computer-assisted diagnosis in medicine. With regard to medical philosophy, decision-making, and diagnosis; the framework of fuzzy sets, systems, and relations is very useful to deal with the absence of sharp boundaries of the sets of symptoms, diagnoses, and phenomena of diseases. The foundations of reasoning and computer assistance in medicine were the result of a rapid accumulation of data from medical research. This explosion of knowledge in medicine gave rise to the speculation that computers could be used for the medical diagnosis. Medicine became, to a certain extent, a quantitative science. In the second half of the 20th century medical knowledge started to be stored in computer systems. To assist physicians in medical decision-making and patient care, medical expert systems using the theory of fuzzy sets and relations (such as the Viennese "fuzzy version" of the Computer-Assisted Diagnostic System, CADIAG, which was developed at the end of the 1970s) were constructed. The development of fuzzy relations in medicine and their application in computer-assisted diagnosis show that this fuzzy approach is a framework to deal with the "fuzzy mode of thinking" in medicine.
Computer Activities for Persons With Dementia.
Tak, Sunghee H; Zhang, Hongmei; Patel, Hetal; Hong, Song Hee
2015-06-01
The study examined participant's experience and individual characteristics during a 7-week computer activity program for persons with dementia. The descriptive study with mixed methods design collected 612 observational logs of computer sessions from 27 study participants, including individual interviews before and after the program. Quantitative data analysis included descriptive statistics, correlational coefficients, t-test, and chi-square. Content analysis was used to analyze qualitative data. Each participant averaged 23 sessions and 591min for 7 weeks. Computer activities included slide shows with music, games, internet use, and emailing. On average, they had a high score of intensity in engagement per session. Women attended significantly more sessions than men. Higher education level was associated with a higher number of different activities used per session and more time spent on online games. Older participants felt more tired. Feeling tired was significantly correlated with a higher number of weeks with only one session attendance per week. More anticholinergic medications taken by participants were significantly associated with a higher percentage of sessions with disengagement. The findings were significant at p < .05. Qualitative content analysis indicated tailoring computer activities appropriate to individual's needs and functioning is critical. All participants needed technical assistance. A framework for tailoring computer activities may provide guidance on developing and maintaining treatment fidelity of tailored computer activity interventions among persons with dementia. Practice guidelines and education protocols may assist caregivers and service providers to integrate computer activities into homes and aging services settings. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Software For Design Of Life-Support Systems
NASA Technical Reports Server (NTRS)
Rudokas, Mary R.; Cantwell, Elizabeth R.; Robinson, Peter I.; Shenk, Timothy W.
1991-01-01
Design Assistant Workstation (DAWN) computer program is prototype of expert software system for analysis and design of regenerative, physical/chemical life-support systems that revitalize air, reclaim water, produce food, and treat waste. Incorporates both conventional software for quantitative mathematical modeling of physical, chemical, and biological processes and expert system offering user stored knowledge about materials and processes. Constructs task tree as it leads user through simulated process, offers alternatives, and indicates where alternative not feasible. Also enables user to jump from one design level to another.
NASA Astrophysics Data System (ADS)
Kartika, H.
2018-03-01
The issue related to making mistake while learning such as negative emotion is found while students learn mathematics with the aid of a computer. When the computer output showed a mistake message, the students considered it as a computer software malfunction. Based on this issue, the writer designs an instructional model based on learning by mistake approach and which is Scilab assisted. The method used in this research is research design involving undergraduate students in matrix algebra courses. The data collected throught survey with questionnaire to gain feedback about the approach implemented. The data analyzed using quantitative descriptive. The instructional design proposed is the student act as a mistake corrector while the teacher acts as a mistake maker. Teacher deliberately makes mistakes with the help of Scilab software. On the other hand, students correct, analyze and explain errors resulting from Scilab software. The result of this research is an ICT based instructional design which is expected to be applicable as an alternative learning in directing students to think positively about mistakes in learning. Furthermore, students are also expected to improve their ability in understanding and thinking critically while solving problems and improving themselves in learning mathematics.
Silveira-Neto, Nicolau; Flores, Mateus Ericson; De Carli, João Paulo; Costa, Max Dória; Matos, Felipe de Souza; Paranhos, Luiz Renato; Linden, Maria Salete Sandini
2017-11-01
This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (α=0.05). The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
Spadaro, Antonia J; Grunbaum, Jo Anne; Dawkins, Nicola U; Wright, Demia S; Rubel, Stephanie K; Green, Diane C; Simoes, Eduardo J
2011-05-01
The Centers for Disease Control and Prevention has administered the Prevention Research Centers Program since 1986. We quantified the number and reach of training programs across all centers, determined whether the centers' outcomes varied by characteristics of the academic institution, and explored potential benefits of training and technical assistance for academic researchers and community partners. We characterized how these activities enhanced capacity building within Prevention Research Centers and the community. The program office collected quantitative information on training across all 33 centers via its Internet-based system from April through December 2007. Qualitative data were collected from April through May 2007. We selected 9 centers each for 2 separate, semistructured, telephone interviews, 1 on training and 1 on technical assistance. Across 24 centers, 4,777 people were trained in 99 training programs in fiscal year 2007 (October 1, 2006-September 30, 2007). Nearly 30% of people trained were community members or agency representatives. Training and technical assistance activities provided opportunities to enhance community partners' capacity in areas such as conducting needs assessments and writing grants and to improve the centers' capacity for cultural competency. Both qualitative and quantitative data demonstrated that training and technical assistance activities can foster capacity building and provide a reciprocal venue to support researchers' and the community's research interests. Future evaluation could assess community and public health partners' perception of centers' training programs and technical assistance.
Shetty, Gautam M; Mullaji, Arun; Bhayde, Sagar
2012-10-01
This prospective study aimed to evaluate radiographically, change in joint line and femoral condylar offset with the optimized gap balancing technique in computer-assisted, primary, cruciate-substituting total knee arthroplasties (TKAs). One hundred and twenty-nine consecutive computer-assisted TKAs were evaluated radiographically using pre- and postoperative full-length standing hip-to-ankle, antero-posterior and lateral radiographs to assess change in knee deformity, joint line height and posterior condylar offset. In 49% of knees, there was a net decrease (mean 2.2mm, range 0.2-8.4mm) in joint line height postoperatively whereas 46.5% of knees had a net increase in joint line height (mean 2.5mm, range 0.2-11.2mm). In 93% of the knees, joint line was restored to within ± 5 mm of preoperative values. In 53% of knees, there was a net increase (mean 2.9 mm, range 0.2-12 mm) in posterior offset postoperatively whereas 40% of knees had a net decrease in posterior offset (mean 4.2mm, range 0.6-20mm). In 82% of knees, the posterior offset was restored within ± 5 mm of preoperative values. Based on radiographic evaluation in extension and at 30° flexion, the current study clearly demonstrates that joint line and posterior femoral condylar offset can be restored in the majority of computer-assisted, cruciate-substituting TKAs to within 5mm of their preoperative value. The optimized gap balancing feature of the computer software allows the surgeon to simulate the effect of simultaneously adjusting femoral component size, position and distal femoral resection level on joint line and posterior femoral offset. Copyright © 2011 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A rapid, quantitative research method using microwave-assisted probe ultrasonication was developed to facilitate the determination of total insoluble, and soluble starch in various sugar factory and refinery products. Several variables that affect starch solubilization were evaluated: 1) conductiv...
USDA-ARS?s Scientific Manuscript database
A rapid, quantitative research method using microwave-assisted probe ultrasonication was developed to facilitate the determination of total insoluble, and soluble starch in various sugar crop products. Several variables that affect starch solubilization were evaluated, 1) conductive boiling time, 2...
Phillips, Brett T; Fourman, Mitchell S; Rivara, Andrew; Dagum, Alexander B; Huston, Tara L; Ganz, Jason C; Bui, Duc T; Khan, Sami U
2014-01-01
Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R(2) = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8.
Fourman, Mitchell S.; Rivara, Andrew; Dagum, Alexander B.; Huston, Tara L.; Ganz, Jason C.; Bui, Duc T.; Khan, Sami U.
2014-01-01
Objective: Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Methods: Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. Results: 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R2 = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Conclusion: Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8. PMID:25525483
ERIC Educational Resources Information Center
Chang, Shao-Chen; Hwang, Gwo-Jen
2017-01-01
In this study, a mission synchronization-based peer-assistance approach is proposed to improve students' learning performance in digital game-based learning activities. To evaluate the effectiveness of the proposed approach, an experiment has been conducted in an elementary school natural science course to examine the participants' learning…
Martin, Curt; Harris, Ashley; DuVall, Nicholas; Wajdowicz, Michael; Roberts, Howard Wayne
2018-03-28
To evaluate the effect of premolar axial wall height on the retention of adhesive, full-coverage, computer-aided design/computer-assisted manufacture (CAD/CAM) restorations. A total of 48 premolar teeth randomized into four groups (n = 12 per group) received all-ceramic CAD/CAM restorations with axial wall heights (AWH) of 3, 2, 1, and 0 mm and 16-degree total occlusal convergence (TOC). Specimens were restored with lithium disilicate material and cemented with self-adhesive resin cement. Specimens were loaded to failure after 24 hours. The 3- and 2-mm AWH specimens demonstrated significantly greater failure load. Failure analysis suggests a 2-mm minimum AWH for premolars with a TOC of 16 degrees. Adhesive technology may compensate for compromised AWH.
Efficacy of a short cognitive training program in patients with multiple sclerosis
Pérez-Martín, María Yaiza; González-Platas, Montserrat; Eguía-del Río, Pablo; Croissier-Elías, Cristina; Jiménez Sosa, Alejandro
2017-01-01
Background Cognitive impairment is a common feature in multiple sclerosis (MS) and may have a substantial impact on quality of life. Evidence about the effectiveness of neuropsychological rehabilitation is still limited, but current data suggest that computer-assisted cognitive training improves cognitive performance. Objective The objective of this study was to evaluate the efficacy of combined computer-assisted training supported by home-based neuropsychological training to improve attention, processing speed, memory and executive functions during 3 consecutive months. Methods In this randomized controlled study blinded for the evaluators, 62 MS patients with clinically stable disease and mild-to-moderate levels of cognitive impairment were randomized to receive a computer-assisted neuropsychological training program (n=30) or no intervention (control group [CG]; n=32). The cognitive assessment included the Brief Repeatable Battery of Neuropsychological Test. Other secondary measures included subjective cognitive impairment, anxiety and depression, fatigue and quality of life measures. Results The treatment group (TG) showed significant improvements in measures of verbal memory, working memory and phonetic fluency after intervention, and repeated measures analysis of covariance revealed a positive effect in most of the functions. The control group (CG) did not show changes. The TG showed a significant reduction in anxiety symptoms and significant improvement in quality of life. There were no improvements in fatigue levels and depressive symptoms. Conclusion Cognitive intervention with a computer-assisted training supported by home training between face-to-face sessions is a useful tool to treat patients with MS and improve functions such as verbal memory, working memory and phonetic fluency. PMID:28223806
Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz
2016-09-07
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
Huang, Jia; McCaskey, Michael A; Yang, Shanli; Ye, Haicheng; Tao, Jing; Jiang, Cai; Schuster-Amft, Corina; Balzer, Christian; Ettlin, Thierry; Schupp, Wilfried; Kulke, Hartwig; Chen, Lidian
2015-12-02
A majority of stroke survivors present with cognitive impairments. Attention disturbance, which leads to impaired concentration and overall reduced cognitive functions, is strongly associated with stroke. The clinical efficacy of acupuncture with Baihui (GV20) and Shenting (GV24) as well as computer-assisted cognitive training in stroke and post-stroke cognitive impairment have both been demonstrated in previous studies. To date, no systematic comparison of these exists and the potential beneficial effects of a combined application are yet to be examined. The main objective of this pilot study is to evaluate the effects of computer-assisted cognitive training compared to acupuncture on the outcomes of attention assessments. The second objective is to test the effects of a combined cognitive intervention that incorporates computer-assisted cognitive training and acupuncture (ACoTrain). An international multicentre, single-blinded, randomised controlled pilot trial will be conducted. In a 1:1:1 ratio, 60 inpatients with post-stroke cognitive dysfunction will be randomly allocated into either the acupuncture group, the computer-assisted cognitive training group, or the ACoTrain group in addition to their individual rehabilitation programme. The intervention period of this pilot trial will last 4 weeks (30 minutes per day, 5 days per week, Monday to Friday). The primary outcome is the test battery for attentional performance. The secondary outcomes include the Trail Making Test, Test des Deux Barrages, National Institute of Health Stroke Scale, and Modified Barthel Index for assessment of daily life competence, and the EuroQol Questionnaire for health-related quality of life. This trial mainly focuses on evaluating the effects of computer-assisted cognitive training compared to acupuncture on the outcomes of attention assessments. The results of this pilot trial are expected to provide new insights on how Eastern and Western medicine can complement one another and improve the treatment of cognitive impairments in early stroke rehabilitation. Including patients with different cultural backgrounds allows a more generalisable interpretation of the results but also poses risks of performance bias. Using standardised and well-described assessments, validated for each region, is pivotal to allow pooling of the data. Clinical Trails.gov ID: NCT02324959 (8 December 2014).
Saletu, B; Anderer, P; Saletu-Zyhlarz, G M; Arnold, O; Pascual-Marqui, R D
2002-01-01
Utilizing computer-assisted quantitative analyses of human scalp-recorded electroencephalogram (EEG) in combination with certain statistical procedures (quantitative pharmaco-EEG) and mapping techniques (pharmaco-EEG mapping), it is possible to classify psychotropic substances and objectively evaluate their bioavailability at the target organ: the human brain. Specifically, one may determine at an early stage of drug development whether a drug is effective on the central nervous system (CNS) compared with placebo, what its clinical efficacy will be like, at which dosage it acts, when it acts and the equipotent dosages of different galenic formulations. Pharmaco-EEG profiles and maps of neuroleptics, antidepressants, tranquilizers, hypnotics, psychostimulants and nootropics/cognition-enhancing drugs will be described in this paper. Methodological problems, as well as the relationships between acute and chronic drug effects, alterations in normal subjects and patients, CNS effects, therapeutic efficacy and pharmacokinetic and pharmacodynamic data will be discussed. In recent times, imaging of drug effects on the regional brain electrical activity of healthy subjects by means of EEG tomography such as low-resolution electromagnetic tomography (LORETA) has been used for identifying brain areas predominantly involved in psychopharmacological action. This will be demonstrated for the representative drugs of the four main psychopharmacological classes, such as 3 mg haloperidol for neuroleptics, 20 mg citalopram for antidepressants, 2 mg lorazepam for tranquilizers and 20 mg methylphenidate for psychostimulants. LORETA demonstrates that these psychopharmacological classes affect brain structures differently.
Addison, Prue F E; Flander, Louisa B; Cook, Carly N
2017-08-01
Protected area management effectiveness (PAME) evaluation is increasingly undertaken to evaluate governance, assess conservation outcomes and inform evidence-based management of protected areas (PAs). Within PAME, quantitative approaches to assess biodiversity outcomes are now emerging, where biological monitoring data are directly assessed against quantitative (numerically defined) condition categories (termed quantitative condition assessments). However, more commonly qualitative condition assessments are employed in PAME, which use descriptive condition categories and are evaluated largely with expert judgement that can be subject to a range of biases, such as linguistic uncertainty and overconfidence. Despite the benefits of increased transparency and repeatability of evaluations, quantitative condition assessments are rarely used in PAME. To understand why, we interviewed practitioners from all Australian marine protected area (MPA) networks, which have access to long-term biological monitoring data and are developing or conducting PAME evaluations. Our research revealed that there is a desire within management agencies to implement quantitative condition assessment of biodiversity outcomes in Australian MPAs. However, practitioners report many challenges in transitioning from undertaking qualitative to quantitative condition assessments of biodiversity outcomes, which are hampering progress. Challenges include a lack of agency capacity (staff numbers and money), knowledge gaps, and diminishing public and political support for PAs. We point to opportunities to target strategies that will assist agencies overcome these challenges, including new decision support tools, approaches to better finance conservation efforts, and to promote more management relevant science. While a single solution is unlikely to achieve full evidence-based conservation, we suggest ways for agencies to target strategies and advance PAME evaluations toward best practice. Copyright © 2017 Elsevier Ltd. All rights reserved.
Computer-assisted semen analysis and its utility for profiling boar semen samples.
Didion, B A
2008-11-01
Achieving and maintaining a successful swine AI program depends on a number of factors, including accurate semen evaluation, typically sperm motility, morphology and concentration. Computer-Assisted Semen Analysis or CASA (i.e., image analysis with a phase-contrast microscope and computer measurements of motion parameters) objectively evaluates sperm motion characteristics, morphology and concentration. A total of 3077 semen collections were evaluated with CASA (on the day of collection), and a semen dose subset was used for single-sire AI of 6266 females over 6 months. Fertility data from these inseminations were fitted with models including farm/stud, line, boar, parity, mating week, semen age at mating and boar age at mating. The residuals from these models showed no correlation for any CASA semen unique motion parameter, which could be due to the level of sperm concentration, the number of inseminations per estrus, and the low number of females mated per boar. Future studies to expand CASA/fertility analysis need to address these constraints and may include analysis of extended boar semen after storage for 1 week.
Musculoskeletal Load in and Highly Repetitive Actions of Animal Facility Washroom Employees
Kiermayer, Claudia; Hoehne-Hückstädt, Ulrike M; Brielmeier, Markus; Brütting, Mark; Ellegast, Rolf; Schmidt, Jörg
2011-01-01
Regular work tasks in the washroom of laboratory animal facilities include cleaning of cages and bottles and handling of chow and bedding. These operations largely are carried out by hand. We quantitatively determined the musculoskeletal load on the trunk and upper limbs of washroom employees in an animal facility with a holding capacity of 35,000 rodent cages by using a computer-assisted, quantitative, recording, and long-term analysis (CUELA) system, which volunteers wore during routine work. Parallel video recording allowed exact assignment of each movement of body and limbs to the data recorded by the sensors. For the most part, trunk movements were unassociated with risk of injury. Evaluation of upper limb movements by CUELA indicated elevated burden on shoulder, elbows, and wrists due to the high repetitiveness and range of movements and postures. However, after additional work factors like low effort and the presence of micropauses were taken into account, workers were not at risk for the development of musculoskeletal disorders of the upper limbs. Handling bottles, chow, and bedding and maneuvering trolleys that entailed greater musculoskeletal loads did not yield evidence of overstraining, because the actions typically were executed alternately and were of short duration during daily shifts. The results represent quantitative information on the musculoskeletal load of regular washroom operations in a laboratory animal facility. These data provide the basis for ergonomic redesign of operations and implementation of automation for highly repetitive movements. PMID:22330713
Robust human machine interface based on head movements applied to assistive robotics.
Perez, Elisa; López, Natalia; Orosco, Eugenio; Soria, Carlos; Mut, Vicente; Freire-Bastos, Teodiano
2013-01-01
This paper presents an interface that uses two different sensing techniques and combines both results through a fusion process to obtain the minimum-variance estimator of the orientation of the user's head. Sensing techniques of the interface are based on an inertial sensor and artificial vision. The orientation of the user's head is used to steer the navigation of a robotic wheelchair. Also, a control algorithm for assistive technology system is presented. The system is evaluated by four individuals with severe motors disability and a quantitative index was developed, in order to objectively evaluate the performance. The results obtained are promising since most users could perform the proposed tasks with the robotic wheelchair.
Robust Human Machine Interface Based on Head Movements Applied to Assistive Robotics
Perez, Elisa; López, Natalia; Orosco, Eugenio; Soria, Carlos; Mut, Vicente; Freire-Bastos, Teodiano
2013-01-01
This paper presents an interface that uses two different sensing techniques and combines both results through a fusion process to obtain the minimum-variance estimator of the orientation of the user's head. Sensing techniques of the interface are based on an inertial sensor and artificial vision. The orientation of the user's head is used to steer the navigation of a robotic wheelchair. Also, a control algorithm for assistive technology system is presented. The system is evaluated by four individuals with severe motors disability and a quantitative index was developed, in order to objectively evaluate the performance. The results obtained are promising since most users could perform the proposed tasks with the robotic wheelchair. PMID:24453877
Simulating realistic predator signatures in quantitative fatty acid signature analysis
Bromaghin, Jeffrey F.
2015-01-01
Diet estimation is an important field within quantitative ecology, providing critical insights into many aspects of ecology and community dynamics. Quantitative fatty acid signature analysis (QFASA) is a prominent method of diet estimation, particularly for marine mammal and bird species. Investigators using QFASA commonly use computer simulation to evaluate statistical characteristics of diet estimators for the populations they study. Similar computer simulations have been used to explore and compare the performance of different variations of the original QFASA diet estimator. In both cases, computer simulations involve bootstrap sampling prey signature data to construct pseudo-predator signatures with known properties. However, bootstrap sample sizes have been selected arbitrarily and pseudo-predator signatures therefore may not have realistic properties. I develop an algorithm to objectively establish bootstrap sample sizes that generates pseudo-predator signatures with realistic properties, thereby enhancing the utility of computer simulation for assessing QFASA estimator performance. The algorithm also appears to be computationally efficient, resulting in bootstrap sample sizes that are smaller than those commonly used. I illustrate the algorithm with an example using data from Chukchi Sea polar bears (Ursus maritimus) and their marine mammal prey. The concepts underlying the approach may have value in other areas of quantitative ecology in which bootstrap samples are post-processed prior to their use.
Dakua, Sarada Prasad; Abinahed, Julien; Al-Ansari, Abdulla
2015-04-01
Liver segmentation continues to remain a major challenge, largely due to its intense complexity with surrounding anatomical structures (stomach, kidney, and heart), high noise level and lack of contrast in pathological computed tomography (CT) data. We present an approach to reconstructing the liver surface in low contrast CT. The main contributions are: (1) a stochastic resonance-based methodology in discrete cosine transform domain is developed to enhance the contrast of pathological liver images, (2) a new formulation is proposed to prevent the object boundary, resulting from the cellular automata method, from leaking into the surrounding areas of similar intensity, and (3) a level-set method is suggested to generate intermediate segmentation contours from two segmented slices distantly located in a subject sequence. We have tested the algorithm on real datasets obtained from two sources, Hamad General Hospital and medical image computing and computer-assisted interventions grand challenge workshop. Various parameters in the algorithm, such as [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text], play imperative roles, thus their values are precisely selected. Both qualitative and quantitative evaluation performed on liver data show promising segmentation accuracy when compared with ground truth data reflecting the potential of the proposed method.
Computed intraoperative navigation guidance--a preliminary report on a new technique.
Enislidis, G; Wagner, A; Ploder, O; Ewers, R
1997-08-01
To assess the value of a computer-assisted three-dimensional guidance system (Virtual Patient System) in maxillofacial operations. Laboratory and open clinical study. Teaching Hospital, Austria. 6 patients undergoing various procedures including removal of foreign body (n=3) and biopsy, maxillary advancement, and insertion of implants (n=1 each). Storage of computed tomographic (CT) pictures on an optical disc, and imposition of intraoperative video images on to these. The resulting display is shown to the surgeon on a micromonitor in his head-up display for guidance during the operations. To improve orientation during complex or minimally invasive maxillofacial procedures and to make such operations easier and less traumatic. Successful transferral of computed navigation technology into an operation room environment and positive evaluation of the method by the surgeons involved. Computer-assisted three-dimensional guidance systems have the potential for making complex or minimally invasive procedures easier to do, thereby reducing postoperative morbidity.
Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng
2018-02-15
To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.
Quantitative imaging biomarkers for dural sinus patterns in idiopathic intracranial hypertension.
Zur, Dinah; Anconina, Reut; Kesler, Anat; Lublinsky, Svetlana; Toledano, Ronen; Shelef, Ilan
2017-02-01
To quantitatively characterize transverse dural sinuses (TS) on magnetic resonance venography (MRV) in patients with idiopathic intracranial hypertension (IIH), compared to healthy controls, using a computer assisted detection (CAD) method. We retrospectively analyzed MRV studies of 38 IIH patients and 30 controls, matched by age and gender. Data analysis was performed using a specially developed Matlab algorithm for vessel cross-sectional analysis. The cross-sectional area and shape measurements were evaluated in patients and controls. Mean, minimal, and maximal cross-sectional areas as well as volumetric parameters of the right and left transverse sinuses were significantly smaller in IIH patients than in controls ( p < .005 for all). Idiopathic intracranial hypertension patients showed a narrowed segment in both TS, clustering near the junction with the sigmoid sinus. In 36% (right TS) and 43% (left TS), the stenosis extended to >50% of the entire length of the TS, i.e. the TS was hypoplastic. Narrower vessels tended to have a more triangular shape than did wider vessels. Using CAD we precisely quantified TS stenosis and its severity in IIH patients by cross-sectional and volumetric analysis. This method can be used as an exact tool for investigating mechanisms of IIH development and response to treatment.
Increased skin and mucosal toxicity in the combination of vemurafenib with radiation therapy.
Merten, Ricarda; Hecht, Markus; Haderlein, Marlen; Distel, Luitpold; Fietkau, Rainer; Heinzerling, Lucie; Semrau, Sabine
2014-11-01
Palliative radiotherapy is often required for patients with metastatic malignant melanoma in the case of bone or brain metastases. Since BRAF inhibitor therapy is highly efficient in V600-mutated melanomas, there is hesitation to stop it during radiotherapy. Consequently, radiotherapy under simultaneous vemurafenib treatment is frequently needed. We report the case of a patient receiving palliative radiotherapy of spinal bone metastases before and during vemurafenib therapy. The skin reactions were quantitatively scored using computer-assisted digital image evaluation. Radiotherapy without vemurafenib was tolerated very well, whereas radiotherapy under simultaneous vemurafenib treatment resulted in accentuated skin reactions. Furthermore, the patient developed dysphagia and had to be hospitalized for parenteral nutrition. In the quantitative analysis, there was a twofold increase in pigmentation and erythema of the irradiated skin area of the thoracic spine when vemurafenib was combined with radiotherapy compared with radiotherapy treatment alone. This is the first reported case of a patient showing no complications during radiotherapy without vemurafenib but remarkable skin and mucosal toxicity under concurrent vemurafenib therapy. Thus, a genetically conditioned individually elevated radiosensitivity can definitely be excluded. Compared with other reported cases, radiosensitization was not limited to the skin, but also affected the esophageal mucosa. Vemurafenib is a strong radiosensitizer. Patients receiving radiotherapy under simultaneous vemurafenib treatment should be monitored very closely.
A quantitative method for evaluating alternatives. [aid to decision making
NASA Technical Reports Server (NTRS)
Forthofer, M. J.
1981-01-01
When faced with choosing between alternatives, people tend to use a number of criteria (often subjective, rather than objective) to decide which is the best alternative for them given their unique situation. The subjectivity inherent in the decision-making process can be reduced by the definition and use of a quantitative method for evaluating alternatives. This type of method can help decision makers achieve degree of uniformity and completeness in the evaluation process, as well as an increased sensitivity to the factors involved. Additional side-effects are better documentation and visibility of the rationale behind the resulting decisions. General guidelines for defining a quantitative method are presented and a particular method (called 'hierarchical weighted average') is defined and applied to the evaluation of design alternatives for a hypothetical computer system capability.
Designing a System for Computer-Assisted Instruction in Road Education: A First Evaluation.
ERIC Educational Resources Information Center
Garcia-Ros, Rafael; Montoro, Luis; Valero, Pedro; Bayarri, Salvador; Martinez, Tomas
1999-01-01
Describes SIVAS, a computer-based system for driver education based on visual simulation that was developed in Spain to support theoretical concepts about driving in driving schools. Explains how teachers can select pre-built scenarios related to driving lessons in order to make up a lecture. (Author/LRW)
ERIC Educational Resources Information Center
Rabiner, David L.; Murray, Desiree W.; Skinner, Ann T; Malone, Patrick S.
2010-01-01
Few studies have examined whether attention can be improved with training, even though attention difficulties adversely affect academic achievement. The present study was a randomized-controlled trial evaluating the impact of Computerized Attention Training (CAT) and Computer Assisted Instruction (CAI) on attention and academic performance in 77…
ERIC Educational Resources Information Center
Reese, Dorothy J.
2012-01-01
The purpose of this quantitative, descriptive/correlational project was to examine the relationship between the level of computer literacy, informatics training, nursing experience, and perceived competence in using computerized patient information systems (CPIS) and nursing resistance to using CPIS. The Nurse Computerized Patient Information…
Factors Influencing F/OSS Cloud Computing Software Product Success: A Quantitative Study
ERIC Educational Resources Information Center
Letort, D. Brian
2012-01-01
Cloud Computing introduces a new business operational model that allows an organization to shift information technology consumption from traditional capital expenditure to operational expenditure. This shift introduces challenges from both the adoption and creation vantage. This study evaluates factors that influence Free/Open Source Software…
Evaluating Computer-Related Incidents on Campus
ERIC Educational Resources Information Center
Rothschild, Daniel; Rezmierski, Virginia
2004-01-01
The Computer Incident Factor Analysis and Categorization (CIFAC) Project at the University of Michigan began in September 2003 with grants from EDUCAUSE and the National Science Foundation (NSF). The project's primary goal is to create a best-practices security framework for colleges and universities based on rigorous quantitative analysis of…
How to quantitatively evaluate safety of driver behavior upon accident? A biomechanical methodology
Zhang, Wen; Cao, Jieer
2017-01-01
How to evaluate driver spontaneous reactions in various collision patterns in a quantitative way is one of the most important topics in vehicle safety. Firstly, this paper constructs representative numerical crash scenarios described by impact velocity, impact angle and contact position based on finite element (FE) computation platform. Secondly, a driver cabin model is extracted and described in the well validated multi-rigid body (MB) model to compute the value of weighted injury criterion to quantitatively assess drivers’ overall injury under certain circumstances. Furthermore, based on the coupling of FE and MB, parametric studies on various crash scenarios are conducted. It is revealed that the WIC (Weighted Injury Criteria) value variation law under high impact velocities is quite distinct comparing with the one in low impact velocities. In addition, the coupling effect can be elucidated by the fact that the difference of WIC value among three impact velocities under smaller impact angles tends to be distinctly higher than that under larger impact angles. Meanwhile, high impact velocity also increases the sensitivity of WIC under different collision positions and impact angles. Results may provide a new methodology to quantitatively evaluate driving behaviors and serve as a significant guiding step towards collision avoidance for autonomous driving vehicles. PMID:29240789
How to quantitatively evaluate safety of driver behavior upon accident? A biomechanical methodology.
Zhang, Wen; Cao, Jieer; Xu, Jun
2017-01-01
How to evaluate driver spontaneous reactions in various collision patterns in a quantitative way is one of the most important topics in vehicle safety. Firstly, this paper constructs representative numerical crash scenarios described by impact velocity, impact angle and contact position based on finite element (FE) computation platform. Secondly, a driver cabin model is extracted and described in the well validated multi-rigid body (MB) model to compute the value of weighted injury criterion to quantitatively assess drivers' overall injury under certain circumstances. Furthermore, based on the coupling of FE and MB, parametric studies on various crash scenarios are conducted. It is revealed that the WIC (Weighted Injury Criteria) value variation law under high impact velocities is quite distinct comparing with the one in low impact velocities. In addition, the coupling effect can be elucidated by the fact that the difference of WIC value among three impact velocities under smaller impact angles tends to be distinctly higher than that under larger impact angles. Meanwhile, high impact velocity also increases the sensitivity of WIC under different collision positions and impact angles. Results may provide a new methodology to quantitatively evaluate driving behaviors and serve as a significant guiding step towards collision avoidance for autonomous driving vehicles.
ERIC Educational Resources Information Center
Dunst, Carl J.; Trivette, Carol M.; Hamby, Deborah W.; Simkus, Andrew
2013-01-01
Findings from a meta-analysis of studies investigating the use of five different assistive technology devices (switch interfaces, powered mobility, computers, augmentative communication, weighted/pressure vests) with young children with disabilities are reported. One hundred and nine studies including 1,342 infants, toddlers, and preschoolers were…
2017-08-01
principles for effective Computer-Based Training (CBT) that can be applied broadly to Army courses to build and evaluate exemplar CBT for Army advanced...individual training courses. To assist cadre who do not have a dedicated instructional design team, the Computer-Based Training Principles Guide was...document is the resulting contents, organization, and presentation style of the Computer- Based Training Principles Guide and its companion User’s Guide
Medical privacy protection based on granular computing.
Wang, Da-Wei; Liau, Churn-Jung; Hsu, Tsan-Sheng
2004-10-01
Based on granular computing methodology, we propose two criteria to quantitatively measure privacy invasion. The total cost criterion measures the effort needed for a data recipient to find private information. The average benefit criterion measures the benefit a data recipient obtains when he received the released data. These two criteria remedy the inadequacy of the deterministic privacy formulation proposed in Proceedings of Asia Pacific Medical Informatics Conference, 2000; Int J Med Inform 2003;71:17-23. Granular computing methodology provides a unified framework for these quantitative measurements and previous bin size and logical approaches. These two new criteria are implemented in a prototype system Cellsecu 2.0. Preliminary system performance evaluation is conducted and reviewed.
Elayavilli, Ravikumar Komandur; Liu, Hongfang
2016-01-01
Computational modeling of biological cascades is of great interest to quantitative biologists. Biomedical text has been a rich source for quantitative information. Gathering quantitative parameters and values from biomedical text is one significant challenge in the early steps of computational modeling as it involves huge manual effort. While automatically extracting such quantitative information from bio-medical text may offer some relief, lack of ontological representation for a subdomain serves as impedance in normalizing textual extractions to a standard representation. This may render textual extractions less meaningful to the domain experts. In this work, we propose a rule-based approach to automatically extract relations involving quantitative data from biomedical text describing ion channel electrophysiology. We further translated the quantitative assertions extracted through text mining to a formal representation that may help in constructing ontology for ion channel events using a rule based approach. We have developed Ion Channel ElectroPhysiology Ontology (ICEPO) by integrating the information represented in closely related ontologies such as, Cell Physiology Ontology (CPO), and Cardiac Electro Physiology Ontology (CPEO) and the knowledge provided by domain experts. The rule-based system achieved an overall F-measure of 68.93% in extracting the quantitative data assertions system on an independently annotated blind data set. We further made an initial attempt in formalizing the quantitative data assertions extracted from the biomedical text into a formal representation that offers potential to facilitate the integration of text mining into ontological workflow, a novel aspect of this study. This work is a case study where we created a platform that provides formal interaction between ontology development and text mining. We have achieved partial success in extracting quantitative assertions from the biomedical text and formalizing them in ontological framework. The ICEPO ontology is available for download at http://openbionlp.org/mutd/supplementarydata/ICEPO/ICEPO.owl.
The current status and future prospects of computer-assisted hip surgery.
Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki
2016-03-01
The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Innovations in Mass Instruction
ERIC Educational Resources Information Center
Perritt, Roscoe D.
1974-01-01
This article deals with teaching accountancy but has wide applications. It describes the graduating teaching seminar, functions of the graduate assistant, computer accounting, honors sections, remedial sessions, report writing, and evaluation procedures. (Editor)
National Security Technology Incubator Evaluation Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This report describes the process by which the National Security Technology Incubator (NSTI) will be evaluated. The technology incubator is being developed as part of the National Security Preparedness Project (NSPP), funded by a Department of Energy (DOE)/National Nuclear Security Administration (NNSA) grant. This report includes a brief description of the components, steps, and measures of the proposed evaluation process. The purpose of the NSPP is to promote national security technologies through business incubation, technology demonstration and validation, and workforce development. The NSTI will focus on serving businesses with national security technology applications by nurturing them through critical stages ofmore » early development. An effective evaluation process of the NSTI is an important step as it can provide qualitative and quantitative information on incubator performance over a given period. The vision of the NSTI is to be a successful incubator of technologies and private enterprise that assist the NNSA in meeting new challenges in national safety and security. The mission of the NSTI is to identify, incubate, and accelerate technologies with national security applications at various stages of development by providing hands-on mentoring and business assistance to small businesses and emerging or growing companies. To achieve success for both incubator businesses and the NSTI program, an evaluation process is essential to effectively measure results and implement corrective processes in the incubation design if needed. The evaluation process design will collect and analyze qualitative and quantitative data through performance evaluation system.« less
NASA Technical Reports Server (NTRS)
Harwood, P. (Principal Investigator); Malin, P.; Finley, R.; Mcculloch, S.; Murphy, D.; Hupp, B.; Schell, J. A.
1977-01-01
The author has identified the following significant results. Four LANDSAT scenes were analyzed for the Harbor Island area test sites to produce land cover and land use maps using both image interpretation and computer-assisted techniques. When evaluated against aerial photography, the mean accuracy for three scenes was 84% for the image interpretation product and 62% for the computer-assisted classification maps. Analysis of the fourth scene was not completed using the image interpretation technique, because of poor quality, false color composite, but was available from the computer technique. Preliminary results indicate that these LANDSAT products can be applied to a variety of planning and management activities in the Texas coastal zone.
Measuring coherence of computer-assisted likelihood ratio methods.
Haraksim, Rudolf; Ramos, Daniel; Meuwly, Didier; Berger, Charles E H
2015-04-01
Measuring the performance of forensic evaluation methods that compute likelihood ratios (LRs) is relevant for both the development and the validation of such methods. A framework of performance characteristics categorized as primary and secondary is introduced in this study to help achieve such development and validation. Ground-truth labelled fingerprint data is used to assess the performance of an example likelihood ratio method in terms of those performance characteristics. Discrimination, calibration, and especially the coherence of this LR method are assessed as a function of the quantity and quality of the trace fingerprint specimen. Assessment of the coherence revealed a weakness of the comparison algorithm in the computer-assisted likelihood ratio method used. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Program-Wide Positive Behavioral Interventions and Supports in Rural Preschools
ERIC Educational Resources Information Center
Steed, Elizabeth A.; Pomerleau, Tina; Muscott, Howard; Rohde, Leigh
2013-01-01
This article describes the quantitative findings from an evaluation of program-wide positive behavioral interventions and supports (PBIS) in three rural preschool programs. Each rural preschool program included children 3 through 5 years of age with and without disabilities. Following 3 years of on-site training, technical assistance, and coaching…
Implementing Adolescent Male Leadership Model to Enhance Behavior, Academic Success
ERIC Educational Resources Information Center
Beliele, Laressa
2012-01-01
Schools are challenged to assist struggling youth. This study used a mixed methods design to evaluate how the school-based program Men of Distinction helps struggling male students develop leadership skills, promoting academic and social success. Quantitative data included attendance, grade point averages, the number of days in in-school…
Jenkins, Sasha; Goel, Ruchika; Morrell, Dean S
2008-08-01
The effectiveness of computer-assisted instruction is unproven. To evaluate the effectiveness of an online computerized dermatology module compared to traditional lecture-based teaching to medical students. Medical students were randomized to two groups. Group 1 of 37 students had access to a computer-based dermatology tutorial. Group 2 of 36 students attended a lecture on skin morphology, identical to the tutorial, given by a dermatology faculty member. The main outcome was the total number of correct answers on a multiple-choice morphologic terminology final examination. The mean number of questions answered correctly was 16.14 and 14.89 for group 1 and group 2, respectively. Unpaired statistical t tests showed the difference in mean scores between the two groups to be 1.25 (95% confidence interval: -0.70 to 3.20, p value = .20). The study was small, with a small amount of material, and was brief in duration. Within the limits of our study, computer-assisted instruction is at least as effective as traditional lecture teaching of dermatology morphology to medical students.
Galli, Manuela; Cimolin, Veronica; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Albertini, Giorgio; Stocchi, Fabrizio; Franceschini, Marco
2016-01-01
Summary The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson’s disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD. PMID:27678210
Using computer-based video analysis in the study of fidgety movements.
Adde, Lars; Helbostad, Jorunn L; Jensenius, Alexander Refsum; Taraldsen, Gunnar; Støen, Ragnhild
2009-09-01
Absence of fidgety movements (FM) in high-risk infants is a strong marker for later cerebral palsy (CP). FMs can be classified by the General Movement Assessment (GMA), based on Gestalt perception of the infant's movement pattern. More objective movement analysis may be provided by computer-based technology. The aim of this study was to explore the feasibility of a computer-based video analysis of infants' spontaneous movements in classifying non-fidgety versus fidgety movements. GMA was performed from video material of the fidgety period in 82 term and preterm infants at low and high risks of developing CP. The same videos were analysed using the developed software called General Movement Toolbox (GMT) with visualisation of the infant's movements for qualitative analyses. Variables derived from the calculation of displacement of pixels from one video frame to the next were used for quantitative analyses. Visual representations from GMT showed easily recognisable patterns of FMs. Of the eight quantitative variables derived, the variability in displacement of a spatial centre of active pixels in the image had the highest sensitivity (81.5) and specificity (70.0) in classifying FMs. By setting triage thresholds at 90% sensitivity and specificity for FM, the need for further referral was reduced by 70%. Video recordings can be used for qualitative and quantitative analyses of FMs provided by GMT. GMT is easy to implement in clinical practice, and may provide assistance in detecting infants without FMs.
Investigation, Development, and Evaluation of Performance Proving for Fault-tolerant Computers
NASA Technical Reports Server (NTRS)
Levitt, K. N.; Schwartz, R.; Hare, D.; Moore, J. S.; Melliar-Smith, P. M.; Shostak, R. E.; Boyer, R. S.; Green, M. W.; Elliott, W. D.
1983-01-01
A number of methodologies for verifying systems and computer based tools that assist users in verifying their systems were developed. These tools were applied to verify in part the SIFT ultrareliable aircraft computer. Topics covered included: STP theorem prover; design verification of SIFT; high level language code verification; assembly language level verification; numerical algorithm verification; verification of flight control programs; and verification of hardware logic.
ICCE/ICCAI 2000 Full & Short Papers (Computer-Assisted Language Learning).
ERIC Educational Resources Information Center
2000
This document contains the following full and short papers on computer-assisted language learning (CALL) from ICCE/ICCAI 2000 (International Conference on Computers in Education/International Conference on Computer-Assisted Instruction): (1) "A Computer-Assisted English Abstract Words Learning Environment on the Web" (Wenli Tsou and…
Warmann, Steven W; Schenk, Andrea; Schaefer, Juergen F; Ebinger, Martin; Blumenstock, Gunnar; Tsiflikas, Ilias; Fuchs, Joerg
2016-11-01
In complex malignant pediatric liver tumors there is an ongoing discussion regarding surgical strategy; for example, primary organ transplantation versus extended resection in hepatoblastoma involving 3 or 4 sectors of the liver. We evaluated the possible role of computer-assisted surgery planning in children with complex hepatic tumors. Between May 2004 and March 2016, 24 Children with complex liver tumors underwent standard multislice helical CT scan or MRI scan at our institution. Imaging data were processed using the software assistant LiverAnalyzer (Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany). Results were provided as Portable Document Format (PDF) with embedded interactive 3-dimensional surface mesh models. Median age of patients was 33months. Diagnoses were hepatoblastoma (n=14), sarcoma (n=3), benign parenchyma alteration (n=2), as well as hepatocellular carcinoma, rhabdoid tumor, focal nodular hyperplasia, hemangioendothelioma, or multiple hepatic metastases of a pancreas carcinoma (each n=1). Volumetry of liver segments identified remarkable variations and substantial aberrances from the Couinaud classification. Computer-assisted surgery planning was used to determine surgical strategies in 20/24 children; this was especially relevant in tumors affecting 3 or 4 liver sectors. Primary liver transplantation could be avoided in 12 of 14 hepaoblastoma patients who theoretically were candidates for this approach. Computer-assisted surgery planning substantially contributed to the decision for surgical strategies in children with complex hepatic tumors. This tool possibly allows determination of specific surgical procedures such as extended surgical resection instead of primary transplantation in certain conditions. Copyright © 2016. Published by Elsevier Inc.
A Quantitative Model for Assessing Visual Simulation Software Architecture
2011-09-01
Software Engineering Arnold Buss Research Associate Professor of MOVES LtCol Jeff Boleng, PhD Associate Professor of Computer Science U.S. Air Force Academy... science (operating and programming systems series). New York, NY, USA: Elsevier Science Ltd. Henry, S., & Kafura, D. (1984). The evaluation of software...Rudy Darken Professor of Computer Science Dissertation Supervisor Ted Lewis Professor of Computer Science Richard Riehle Professor of Practice
Computer-assisted innovations in craniofacial surgery.
Rudman, Kelli; Hoekzema, Craig; Rhee, John
2011-08-01
Reconstructive surgery for complex craniofacial defects challenges even the most experienced surgeons. Preoperative reconstructive planning requires consideration of both functional and aesthetic properties of the mandible, orbit, and midface. Technological innovations allow for computer-assisted preoperative planning, computer-aided manufacturing of patient-specific implants (PSIs), and computer-assisted intraoperative navigation. Although many case reports discuss computer-assisted preoperative planning and creation of custom implants, a general overview of computer-assisted innovations is not readily available. This article reviews innovations in computer-assisted reconstructive surgery including anatomic considerations when using PSIs, technologies available for preoperative planning, work flow and process of obtaining a PSI, and implant materials available for PSIs. A case example follows illustrating the use of this technology in the reconstruction of an orbital-frontal-temporal defect with a PSI. Computer-assisted reconstruction of complex craniofacial defects provides the reconstructive surgeon with innovative options for challenging reconstructive cases. As technology advances, applications of computer-assisted reconstruction will continue to expand. © Thieme Medical Publishers.
NASA Astrophysics Data System (ADS)
Suwannasri, A.; Kaewlai, R.; Asavaphatiboon, S.
2016-03-01
This study was to determine if administration of a low volume high-concentration iodinated contrast medium can preserve image quality in comparison with regular-concentration intravenous contrast medium in patient undergoing contrast-enhancement abdominal computed tomography (CT). Eighty-four patients were randomly divided into 3 groups of similar iodine delivery rate; A: 1.2 cc/kg of iomeprol-400, B: 1.0 cc/kg of iomeprol-400 and C: 1.5 cc/kg of ioversol-350. Contrast enhancement of the liver parenchyma, pancreas and aorta was quantitatively measured in Hounsfield units and qualitative assessed by a radiologist. T-test was used to evaluate contrast enhancement, and Chi-square test was used to evaluate qualitative image assessment, at significance level of 0.05 with 95% confidence intervals. There were no statistically significant differences in contrast enhancement of liver parenchyma and pancreas between group A and group C in both quantitative and qualitative analyses. Group C showed superior vascular enhancement to group A and B on quantitative analysis.
Implementation of Health Information Technology in Routine Care for Fibromyalgia: Pilot Study.
Sparks, Toni; Kawi, Jennifer; Menzel, Nancy Nivison; Hartley, Kendall
2016-02-01
Fibromyalgia management remains complicated and challenging. Health information technology is an evidence-based, nonpharmacological self and symptom management strategy, but few studies have evaluated its feasibility for managing fibromyalgia patients in clinical practice. FibroGuide is an example of an evidence-based, interactive, and computer-based program comprised of 10 educational modules on fibromyalgia. Study aims were to: (1) develop a process for implementing FibroGuide into the routine care of patients with fibromyalgia, (2) evaluate the overall impact on fibromyalgia before and after a 12-week implementation, and (3) assess patient perspectives on using FibroGuide health information technology to assist in self-management. In this pilot study, 35 participants with fibromyalgia were recruited from an Advanced Practice Registered Nurse's outpatient clinic. Using a descriptive design, quantitative data analysis was employed to address study aims. Based on data collection pre- and post-intervention using paired samples testing, a statistically significant change (p = .017) was observed in overall fibromyalgia impact (improved symptom severity, activity, and function). Majority felt that FibroGuide was helpful as part of their routine care, and nearly half reported that it assisted in their self-management. Although 65% noted that technology was an effective and efficient way to receive education for fibromyalgia management, 57% preferred talking to healthcare providers. Larger longitudinal studies are needed on the use of health information technology in fibromyalgia, evaluating both statistical and clinical significance, while decreasing barriers to participant use for this promising adjunct to clinical management. Providers need to be well educated on supporting self-management strategies and health information technology. Copyright © 2016 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
Mobile augmented reality for computer-assisted percutaneous nephrolithotomy.
Müller, Michael; Rassweiler, Marie-Claire; Klein, Jan; Seitel, Alexander; Gondan, Matthias; Baumhauer, Matthias; Teber, Dogu; Rassweiler, Jens J; Meinzer, Hans-Peter; Maier-Hein, Lena
2013-07-01
Percutaneous nephrolithotomy (PCNL) plays an integral role in treatment of renal stones. Creating percutaneous renal access is the most important and challenging step in the procedure. To facilitate this step, we evaluated our novel mobile augmented reality (AR) system for its feasibility of use for PCNL. A tablet computer, such as an iPad[Formula: see text], is positioned above the patient with its camera pointing toward the field of intervention. The images of the tablet camera are registered with the CT image by means of fiducial markers. Structures of interest can be superimposed semi-transparently on the video images. We present a systematic evaluation by means of a phantom study. An urological trainee and two experts conducted 53 punctures on kidney phantoms. The trainee performed best with the proposed AR system in terms of puncturing time (mean: 99 s), whereas the experts performed best with fluoroscopy (mean: 59 s). iPad assistance lowered radiation exposure by a factor of 3 for the inexperienced physician and by a factor of 1.8 for the experts in comparison with fluoroscopy usage. We achieve a mean visualization accuracy of 2.5 mm. The proposed tablet computer-based AR system has proven helpful in assisting percutaneous interventions such as PCNL and shows benefits compared to other state-of-the-art assistance systems. A drawback of the system in its current state is the lack of depth information. Despite that, the simple integration into the clinical workflow highlights the potential impact of this approach to such interventions.
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, Brandon D.; Chan, Heang-Ping; D’Orsi, Carl J.; Dodd, Lori E.; Giger, Maryellen L.; Gur, David; Krupinski, Elizabeth A.; Metz, Charles E.; Myers, Kyle J.; Obuchowski, Nancy A.; Sahiner, Berkman; Toledano, Alicia Y.; Zuley, Margarita L.
2017-01-01
This report summarizes the Joint FDA-MIPS Workshop on Methods for the Evaluation of Imaging and Computer-Assist Devices. The purpose of the workshop was to gather information on the current state of the science and facilitate consensus development on statistical methods and study designs for the evaluation of imaging devices to support US Food and Drug Administration submissions. Additionally, participants expected to identify gaps in knowledge and unmet needs that should be addressed in future research. This summary is intended to document the topics that were discussed at the meeting and disseminate the lessons that have been learned through past studies of imaging and computer-aided detection and diagnosis device performance. PMID:22306064
Chaudhary, Richa; Grover, Chander; Bhattacharya, S N; Sharma, Arun
2017-01-01
The assessment of dermatology undergraduates is being done through computer assisted objective structured clinical examination at our institution for the last 4 years. We attempted to compare objective structured clinical examination (OSCE) and computer assisted objective structured clinical examination (CA-OSCE) as assessment tools. To assess the relative effectiveness of CA-OSCE and OSCE as assessment tools for undergraduate dermatology trainees. Students underwent CA-OSCE as well as OSCE-based evaluation of equal weightage as an end of posting assessment. The attendance as well as the marks in both the examination formats were meticulously recorded and statistically analyzed using SPSS version 20.0. Intercooled Stata V9.0 was used to assess the reliability and internal consistency of the examinations conducted. Feedback from both students and examiners was also recorded. The mean attendance for the study group was 77% ± 12.0%. The average score on CA- OSCE and OSCE was 47.4% ± 19.8% and 53.5% ± 18%, respectively. These scores showed a mutually positive correlation, with Spearman's coefficient being 0.593. Spearman's rank correlation coefficient between attendance scores and assessment score was 0.485 for OSCE and 0.451 for CA-OSCE. The Cronbach's alpha coefficient for all the tests ranged from 0.76 to 0.87 indicating high reliability. The comparison was based on a single batch of 139 students. Such an evaluation on more students in larger number of batches over successive years could help throw more light on the subject. Computer assisted objective structured clinical examination was found to be a valid, reliable and effective format for dermatology assessment, being rated as the preferred format by examiners.
Implementing Computer Technology in the Rehabilitation Process.
ERIC Educational Resources Information Center
McCollum, Paul S., Ed.; Chan, Fong, Ed.
1985-01-01
This special issue contains seven articles, addressing rehabilitation in the information age, computer-assisted rehabilitation services, computer technology in rehabilitation counseling, computer-assisted career exploration and vocational decision making, computer-assisted assessment, computer enhanced employment opportunities for persons with…
Klein, M D; Rabbani, A B; Rood, K D; Durham, T; Rosenberg, N M; Bahr, M J; Thomas, R L; Langenburg, S E; Kuhns, L R
2001-09-01
The authors compared 3 quantitative methods for assisting clinicians in the differential diagnosis of abdominal pain in children, where the most common important endpoint is whether the patient has appendicitis. Pretest probability in different age and sex groups were determined to perform Bayesian analysis, binary logistic regression was used to determine which variables were statistically significantly likely to contribute to a diagnosis, and recursive partitioning was used to build decision trees with quantitative endpoints. The records of all children (1,208) seen at a large urban emergency department (ED) with a chief complaint of abdominal pain were immediately reviewed retrospectively (24 to 72 hours after the encounter). Attempts were made to contact all the patients' families to determine an accurate final diagnosis. A total of 1,008 (83%) families were contacted. Data were analyzed by calculation of the posttest probability, recursive partitioning, and binary logistic regression. In all groups the most common diagnosis was abdominal pain (ICD-9 Code 789). After this, however, the order of the most common final diagnoses for abdominal pain varied significantly. The entire group had a pretest probability of appendicitis of 0.06. This varied with age and sex from 0.02 in boys 2 to 5 years old to 0.16 in boys older than 12 years. In boys age 5 to 12, recursive partitioning and binary logistic regression agreed on guarding and anorexia as important variables. Guarding and tenderness were important in girls age 5 to 12. In boys age greater than 12, both agreed on guarding and anorexia. Using sensitivities and specificities from the literature, computed tomography improved the posttest probability for the group from.06 to.33; ultrasound improved it from.06 to.48; and barium enema improved it from.06 to.58. Knowing the pretest probabilities in a specific population allows the physician to evaluate the likely diagnoses first. Other quantitative methods can help judge how much importance a certain criterion should have in the decision making and how much a particular test is likely to influence the probability of a correct diagnosis. It now should be possible to make these sophisticated quantitative methods readily available to clinicians via the computer. Copyright 2001 by W.B. Saunders Company.
NASA Astrophysics Data System (ADS)
Al-Shammari, Abdulrahman G. Alhamzani
2008-10-01
Two approaches to enhance the understanding of organic reaction mechanisms are described. First, a new method for teaching organic reaction mechanisms that can be used in a Computer-Assisted Instruction (CAI) environment is proposed and tested (Chapter 1). The method concentrates upon the important intermediate structures, which are assumed to be on the reaction coordinate, and which can be evaluated and graded by currently available computer techniques. At the same time, the "curved arrows" that show the electron flow in a reaction mechanism are neglected, since they cannot be evaluated and graded with currently available computer techniques. By allowing student practice for learning organic reaction mechanisms using the Curved Arrow Neglect (CAN) method within a "Practice Makes Perfect" CAI method, student performance in the drawing of traditional reaction mechanisms, in which students had to include the "curved arrows" on their written classroom exams, was significantly enhanced. Second, computerized prelaboratory experiments (CPLEX) for organic chemistry laboratory 1 & 2 courses have been created, used, and evaluated (Chapters 2 and 3). These computerized prelabs are unique because they combine both "dry lab" actions with detailed animations of the actual chemistry occurring at the molecular level. The "dry lab" serves to simulate the actual physical manipulations of equipment and chemicals that occur in the laboratory experiment through the use of drag-and-drop computer technology. At the same time, these physical actions are accompanied on a separate part of the computer screen by animations showing the chemistry at the molecular level that is occurring in the experiment. These CPLEX modules were made into Internet accessible modules. The students were allowed to access the CPLEX modules prior to performing the actual laboratory experiment. A detailed evaluation of students' perception of the modules was accomplished via survey methodology during the entire implementation process over the course of three semesters. Results of the survey data indicate that students thought that they better understood the chemical principles and procedures of the laboratory experiment. Interestingly, students prefer the CPLEX prelaboratory materials, compared to the traditional textbooks, by a wide margin (Chapter 2). The utility of CPLEX was further demonstrated by enabling a study of the effectiveness of animated reaction mechanisms to promote student learning. While most instructors believe that animated mechanisms aid student understanding of reactions, there has been no quantitative data to-date to support this view. In this work, a quantitative study, using an experimental/control group study, was conducted to provide data on the effectiveness of animated reaction mechanisms to promote student learning. Analysis of student answers, using an appropriate rubric, demonstrated that there was a statistically significant improvement in students' scores in the mechanistic question of a pre-laboratory quiz in the post-treatment results of the experimental group which had had access to the animated reaction mechanisms (Chapter 3).
History of computer-assisted orthopedic surgery (CAOS) in sports medicine.
Jackson, Douglas W; Simon, Timothy M
2008-06-01
Computer-assisted orthopedic surgery and navigation applications have a history rooted in the desire to link imaging technology with real-time anatomic landmarks. Although applications are still evolving in the clinical and research setting, computer-assisted orthopedic surgery has already demonstrated in certain procedures its potential for improving the surgeon's accuracy, reproducibility (once past the learning curve), and in reducing outlier outcomes. It is also being used as an educational tool to assist less experienced surgeons in interpreting measurements and precision placements related to well defined anatomic landmarks. It also can assist experienced surgeons, in real-time, plan their bony cuts, tunnel placement, and with ligament balancing. Presently, the additional time, the expense to acquire the needed software and hardware, and restricted reimbursement have slowed the widespread use of navigation. Its current applications have been primarily in joint replacement surgery, spine surgery, and trauma. It has not been widely used in the clinical setting for sports medicine procedures. Sports medicine applications such as individualizing tunnel placement in ligament surgery, opening wedge osteotomy with and without accompanying ligament reconstruction, and balancing and tensioning of the ligaments during the procedure (allowing real-time corrections if necessary) are currently being evaluated and being used on a limited clinical basis.
The Practical Concept of an Evaluator and Its Use in the Design of Training Systems.
ERIC Educational Resources Information Center
Gibbons, Andrew S.; Rogers, Dwayne H.
1991-01-01
The evaluator is an instructional system product that provides practice, testing capability, and feedback in a way not yet seen in computer-assisted instruction. Training methods using an evaluator contain scenario-based simulation exercises, followed by a critique of performance. A focus on competency-based education and performance makes the…
ERIC Educational Resources Information Center
Ghilay, Yaron; Ghilay, Ruth
2012-01-01
The study examined advantages and disadvantages of computerised assessment compared to traditional evaluation. It was based on two samples of college students (n=54) being examined in computerised tests instead of paper-based exams. Students were asked to answer a questionnaire focused on test effectiveness, experience, flexibility and integrity.…
ERIC Educational Resources Information Center
Hawk, Kim; And Others
This document contains a project report and tutor manual from a demonstration project conducted by the Fayette County Community Action Agency (FCCAA) of Fayette County, Pennsylvania to evaluate the effectiveness of using computers and selected reading software in conjunction with traditional one-on-one tutoring to teach reading skills to…
ERIC Educational Resources Information Center
Hopf-Weichel, Rosemarie; And Others
This report describes results of the first year of a three-year program to develop and evaluate a new Adaptive Computerized Training System (ACTS) for electronics maintenance training. (ACTS incorporates an adaptive computer program that learns the student's diagnostic and decision value structure, compares it to that of an expert, and adapts the…
Computer-Guided Diagnosis of Learning Disabilities: A Prototype.
ERIC Educational Resources Information Center
Colbourn, Marlene Jones
A computer based diagnostic system to assist educators in the assessment of learning disabled children aged 8 to 10 years in the area of reading is described and evaluated. The system is intended to guide the diagnosis of reading problems through step by step analysis of available data and requests for additional data. The system provides a…
Integrating Computer-Based Career Development into Your Career Planning Program.
ERIC Educational Resources Information Center
Campbell, Robert B.; Mack, Sharon E.
This paper focuses on the real and theoretical usefulness of a computer-based career development system in a career planning program, based on a 2-year pilot program evaluating the DISCOVER system. The system overview discusses components and contents of DISCOVER, and describes the 11 modules which assist users in learning about their values,…
Risk in Enterprise Cloud Computing: Re-Evaluated
ERIC Educational Resources Information Center
Funmilayo, Bolonduro, R.
2016-01-01
A quantitative study was conducted to get the perspectives of IT experts about risks in enterprise cloud computing. In businesses, these IT experts are often not in positions to prioritize business needs. The business experts commonly known as business managers mostly determine an organization's business needs. Even if an IT expert classified a…
Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A
2008-01-01
To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.
Quantitative evaluation of software packages for single-molecule localization microscopy.
Sage, Daniel; Kirshner, Hagai; Pengo, Thomas; Stuurman, Nico; Min, Junhong; Manley, Suliana; Unser, Michael
2015-08-01
The quality of super-resolution images obtained by single-molecule localization microscopy (SMLM) depends largely on the software used to detect and accurately localize point sources. In this work, we focus on the computational aspects of super-resolution microscopy and present a comprehensive evaluation of localization software packages. Our philosophy is to evaluate each package as a whole, thus maintaining the integrity of the software. We prepared synthetic data that represent three-dimensional structures modeled after biological components, taking excitation parameters, noise sources, point-spread functions and pixelation into account. We then asked developers to run their software on our data; most responded favorably, allowing us to present a broad picture of the methods available. We evaluated their results using quantitative and user-interpretable criteria: detection rate, accuracy, quality of image reconstruction, resolution, software usability and computational resources. These metrics reflect the various tradeoffs of SMLM software packages and help users to choose the software that fits their needs.
A Computational Framework for Quantitative Evaluation of Movement during Rehabilitation
NASA Astrophysics Data System (ADS)
Chen, Yinpeng; Duff, Margaret; Lehrer, Nicole; Sundaram, Hari; He, Jiping; Wolf, Steven L.; Rikakis, Thanassis
2011-06-01
This paper presents a novel generalized computational framework for quantitative kinematic evaluation of movement in a rehabilitation clinic setting. The framework integrates clinical knowledge and computational data-driven analysis together in a systematic manner. The framework provides three key benefits to rehabilitation: (a) the resulting continuous normalized measure allows the clinician to monitor movement quality on a fine scale and easily compare impairments across participants, (b) the framework reveals the effect of individual movement components on the composite movement performance helping the clinician decide the training foci, and (c) the evaluation runs in real-time, which allows the clinician to constantly track a patient's progress and make appropriate adaptations to the therapy protocol. The creation of such an evaluation is difficult because of the sparse amount of recorded clinical observations, the high dimensionality of movement and high variations in subject's performance. We address these issues by modeling the evaluation function as linear combination of multiple normalized kinematic attributes y = Σwiφi(xi) and estimating the attribute normalization function φi(ṡ) by integrating distributions of idealized movement and deviated movement. The weights wi are derived from a therapist's pair-wise comparison using a modified RankSVM algorithm. We have applied this framework to evaluate upper limb movement for stroke survivors with excellent results—the evaluation results are highly correlated to the therapist's observations.
ERIC Educational Resources Information Center
Shih, Ching-Hsiang; Chang, Man-Ling; Shih, Ching-Tien
2009-01-01
This study evaluated whether two people with multiple disabilities and minimal motor behavior would be able to improve their pointing performance using finger poke ability with a mouse wheel through a Dynamic Pointing Assistive Program (DPAP) and a newly developed mouse driver (i.e., a new mouse driver replaces standard mouse driver, changes a…
ERIC Educational Resources Information Center
Shih, Ching-Hsiang; Chiu, Sheng-Kai; Chu, Chiung-Ling; Shih, Ching-Tien; Liao, Yung-Kun; Lin, Chia-Chen
2010-01-01
This study evaluated whether two people with multiple disabilities would be able to improve their pointing performance using hand swing with a standard mouse through an Extended Dynamic Pointing Assistive Program (EDPAP) and a newly developed mouse driver (i.e., a new mouse driver replaces standard mouse driver, and changes a mouse into a precise…
What Today's Educational Technology Needs: Defensible Evaluations and Realistic Implementation.
ERIC Educational Resources Information Center
Roweton, William E.; And Others
It is argued that in order to make computer assisted instruction effective in the schools, educators should pay more attention to implementation issues (including modifying teacher attitudes, changing classroom routines, and offering realistic technical training and support) and to producing understandable product and performance evaluations.…
Caffeine. Courseware Evaluation for Vocational and Technical Education.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This courseware evaluation rates the "Caffeine" program developed by Lane Community College and sold by the Oregon Department of Education. (The program--not included in this document--is part of a computer-assisted instruction project with nursing applications.) Part A describes "Caffeine" in terms of topics (food and…
The CAI/Cooperative Learning Project. First Year Evaluation Report.
ERIC Educational Resources Information Center
Beyer, Francine S.
This report presents a first year evaluation of the Computer Assisted Instruction (CAI)/ Cooperative Learning Project, a 3-year collaborative effort by two Pennsylvania school districts--the Pittston Area School District and the Hatboro-Horsham School District--and Research for Better Schools (RBS). The project proposed to integrate advanced…
Usability of a Low-Cost Head Tracking Computer Access Method following Stroke.
Mah, Jasmine; Jutai, Jeffrey W; Finestone, Hillel; Mckee, Hilary; Carter, Melanie
2015-01-01
Assistive technology devices for computer access can facilitate social reintegration and promote independence for people who have had a stroke. This work describes the exploration of the usefulness and acceptability of a new computer access device called the Nouse™ (Nose-as-mouse). The device uses standard webcam and video recognition algorithms to map the movement of the user's nose to a computer cursor, thereby allowing hands-free computer operation. Ten participants receiving in- or outpatient stroke rehabilitation completed a series of standardized and everyday computer tasks using the Nouse™ and then completed a device usability questionnaire. Task completion rates were high (90%) for computer activities only in the absence of time constraints. Most of the participants were satisfied with ease of use (70%) and liked using the Nouse™ (60%), indicating they could resume most of their usual computer activities apart from word-processing using the device. The findings suggest that hands-free computer access devices like the Nouse™ may be an option for people who experience upper motor impairment caused by stroke and are highly motivated to resume personal computing. More research is necessary to further evaluate the effectiveness of this technology, especially in relation to other computer access assistive technology devices.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-03
...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This technical note describes the current capabilities and availability of the Automated Dredging and Disposal Alternatives Management System (ADDAMS). The technical note replaces the earlier Technical Note EEDP-06-12, which should be discarded. Planning, design, and management of dredging and dredged material disposal projects often require complex or tedious calculations or involve complex decision-making criteria. In addition, the evaluations often must be done for several disposal alternatives or disposal sites. ADDAMS is a personal computer (PC)-based system developed to assist in making such evaluations in a timely manner. ADDAMS contains a collection of computer programs (applications) designed to assist in managingmore » dredging projects. This technical note describes the system, currently available applications, mechanisms for acquiring and running the system, and provisions for revision and expansion.« less
Johnson, Kenneth A; Ruppe, Joan
2002-01-01
This project was conducted with a multicultural construction company in Hawaii, USA. The job duties performed included drywall and carpentry work. The following objectives were selected for this project: (a) fire prevention training and inspection of first aid equipment; (b) blood-borne pathogen training and risk evaluation; (c) ergonomic and risk evaluation intervention program; (d) electrical safety training and inspection program; (e) slips, trips, and falls safety training; (f) stress assessment and Personal Profile System; (g) safety and health program survey; (h) improving employee relations and morale by emphasizing spirituality; and (i) computer-assisted biofeedback stress management training. Results of the project indicated that observed safety hazards, reported injuries, and levels of perceived stress. were reduced for the majority of the population.
An analysis of computer-assisted pre-screening prior to elective surgery.
Grant, C; Ludbrook, G L; O'Loughlin, E J; Corcoran, T B
2012-03-01
In order to assess the potential utility of guided patient self-assessment as an early preoperative triage tool, a computer-assisted questionnaire delivered by a non-clinician via telephone was 1) compared to face-to-face interview and examination by anaesthetists in outpatient clinics and 2) evaluated as a mechanism to stream patients to day of surgery assessment. In total, 514 patients scheduled for elective surgery in two tertiary public hospitals were assessed initially by telephone and then in an outpatient clinic. Both forms of assessment were marked by panels of specialist anaesthetists, who also provided an opinion on which patients would have been suitable to bypass preoperative anaesthetic outpatient assessment based upon information provided by the telephone interview. Overall, the quality of assessment provided by non-clinician telephone interview was comparable to face-to-face interview by anaesthetists, although more complex issues required face-to-face assessment. Panel review considered that 398 patients (60%) would not have required evaluation by an anaesthetist until the day of surgery, thus avoiding the need to separately attend a preoperative outpatient clinic. The sensitivity of telephone interview provided information to correctly classify patients as suitable for day of surgery evaluation was 98% (95% confidence interval 96 to 99%) with a specificity of 97% (95% confidence interval 92 to 98%). This study demonstrates that remote computer-assisted assessment can produce quality patient health information and enable early patient work-up and triage with the potential to reduce costs through more efficient use of resources.
1984-09-01
records/documents in the division *- are quantitative in nature and are contained in computer printouts. Other documents include daily transactions docu...1498-1830). Venezuela was discovered by Christopher Columbus during his third voyage to the new world in 1498 (25:2). He was intrigued by pearl...maintain control, trade with other countries was forbidden and resulted in the colony’s isolation for most of *O its early existence. News of the new
Mobile medical computing driven by the complexity of neurologic diagnosis.
Segal, Michael M
2006-07-01
Medical computing has been split between palm-sized computers optimized for mobility and desktop computers optimized for capability. This split was due to technology too immature to deliver both mobility and capability in the same computer and the lack of medical software that demanded both mobility and capability. Advances in hardware and software are ushering in an era in which fully capable computers will be available ubiquitously. As a result, medical practice, education and publishing will change. Medical practice will be improved by the use of software that not only assists with diagnosis but can do so at the bedside, where the doctor can act immediately upon suggestions such as useful findings to check. Medical education will shift away from a focus on details of unusual diseases and toward a focus on skills of physical examination and using computerized tools. Medical publishing, in contrast, will shift toward greater detail: it will be increasingly important to quantitate the frequency of findings in diseases and their time course since such information can have a major impact clinically when added to decision support software.
Venne, Gabriel; Rasquinha, Brian J; Pichora, David; Ellis, Randy E; Bicknell, Ryan
2015-07-01
Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05). Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05). We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Flood hazard studies in Central Texas using orbital and suborbital remote sensing machinery
NASA Technical Reports Server (NTRS)
Baker, V. R.; Holz, R. K.; Patton, P. C.
1975-01-01
Central Texas is subject to infrequent, unusually intense rainstorms which cause extremely rapid runoff from drainage basins developed on the deeply dissected limestone and marl bedrock of the Edwards Plateau. One approach to flood hazard evaluation in this area is a parametric model relating flood hydrograph characteristics to quantitative geomorphic properties of the drainage basins. The preliminary model uses multiple regression techniques to predict potential peak flood discharge from basin magnitude, drainage density, and ruggedness number. After mapping small catchment networks from remote sensing imagery, input data for the model are generated by network digitization and analysis by a computer assisted routine of watershed analysis. The study evaluated the network resolution capabilities of the following data formats: (1) large-scale (1:24,000) topographic maps, employing Strahler's "method of v's," (2) standard low altitude black and white aerial photography (1:13,000 and 1:20,000 scales), (3) NASA - generated aerial infrared photography at scales ranging from 1:48,000 to 1:123,000, and (4) Skylab Earth Resources Experiment Package S-190A and S-190B sensors (1:750,000 and 1:500,000 respectively).
Development of a questionnaire for quantitative assessment in the field of health and human rights.
Wildner, Manfred; Fischer, Richela; Brunner, Anne
2002-11-01
We hypothesize that a human rights framework would be able to analyse central health-related societal issues within important settings like the work place, the family or the health care system. Our study goal was the development and population-based evaluation of a questionnaire for assessment of the perceived human rights status. A questionnaire (HR-14) was developed from the guiding principles of international human rights legislation. For its psychometric evaluation, computer-assisted telephone interviews were conducted in four cities in Europe (Munich, Dresden, Vienna and Bern). Cronbach's alpha for internal consistency was 0.76. Factor analysis supported the concept of human rights as indivisible and interdependent. Extracted factors were consistent with the preliminary settings of family and friends, health care system and community at large, and a supplementary setting workplace. Perceived human rights status was associated with physical function, mental/emotional health, age, study region, general health and employment status. We conclude that it is possible to develop a human rights questionnaire with good psychometric properties. Measurement of the perceived human rights status of populations and population groups may contribute to health policies sensitive to human rights.
NASA Astrophysics Data System (ADS)
Li, Zhenwei; Sun, Jianyong; Zhang, Jianguo
2012-02-01
As more and more CT/MR studies are scanning with larger volume of data sets, more and more radiologists and clinician would like using PACS WS to display and manipulate these larger data sets of images with 3D rendering features. In this paper, we proposed a design method and implantation strategy to develop 3D image display component not only with normal 3D display functions but also with multi-modal medical image fusion as well as compute-assisted diagnosis of coronary heart diseases. The 3D component has been integrated into the PACS display workstation of Shanghai Huadong Hospital, and the clinical practice showed that it is easy for radiologists and physicians to use these 3D functions such as multi-modalities' (e.g. CT, MRI, PET, SPECT) visualization, registration and fusion, and the lesion quantitative measurements. The users were satisfying with the rendering speeds and quality of 3D reconstruction. The advantages of the component include low requirements for computer hardware, easy integration, reliable performance and comfortable application experience. With this system, the radiologists and the clinicians can manipulate with 3D images easily, and use the advanced visualization tools to facilitate their work with a PACS display workstation at any time.
Cohen, Stephanie A; McIlvried, Dawn E
2011-06-01
Cancer genetic counseling sessions traditionally encompass collecting medical and family history information, evaluating that information for the likelihood of a genetic predisposition for a hereditary cancer syndrome, conveying that information to the patient, offering genetic testing when appropriate, obtaining consent and subsequently documenting the encounter with a clinic note and pedigree. Software programs exist to collect family and medical history information electronically, intending to improve efficiency and simplicity of collecting, managing and storing this data. This study compares the genetic counselor's time spent in cancer genetic counseling tasks in a traditional model and one using computer-assisted data collection, which is then used to generate a pedigree, risk assessment and consult note. Genetic counselor time spent collecting family and medical history and providing face-to-face counseling for a new patient session decreased from an average of 85-69 min when using the computer-assisted data collection. However, there was no statistically significant change in overall genetic counselor time on all aspects of the genetic counseling process, due to an increased amount of time spent generating an electronic pedigree and consult note. Improvements in the computer program's technical design would potentially minimize data manipulation. Certain aspects of this program, such as electronic collection of family history and risk assessment, appear effective in improving cancer genetic counseling efficiency while others, such as generating an electronic pedigree and consult note, do not.
ERIC Educational Resources Information Center
Yan, Zi; Sendall, Patricia
2016-01-01
While many American colleges and universities are providing a First Year Experience (FYE) course or program for their first year students, those programs are not often customized to take into account international students' (IS) unique challenges. Using quantitative and qualitative methods, this study evaluated a FYE course that was customized for…
Computer-Assisted Exposure Treatment for Flight Phobia
ERIC Educational Resources Information Center
Tortella-Feliu, Miguel; Bornas, Xavier; Llabres, Jordi
2008-01-01
This review introduces the state of the art in computer-assisted treatment for behavioural disorders. The core of the paper is devoted to describe one of these interventions providing computer-assisted exposure for flight phobia treatment, the Computer-Assisted Fear of Flying Treatment (CAFFT). The rationale, contents and structure of the CAFFT…
Method and tool for network vulnerability analysis
Swiler, Laura Painton [Albuquerque, NM; Phillips, Cynthia A [Albuquerque, NM
2006-03-14
A computer system analysis tool and method that will allow for qualitative and quantitative assessment of security attributes and vulnerabilities in systems including computer networks. The invention is based on generation of attack graphs wherein each node represents a possible attack state and each edge represents a change in state caused by a single action taken by an attacker or unwitting assistant. Edges are weighted using metrics such as attacker effort, likelihood of attack success, or time to succeed. Generation of an attack graph is accomplished by matching information about attack requirements (specified in "attack templates") to information about computer system configuration (contained in a configuration file that can be updated to reflect system changes occurring during the course of an attack) and assumed attacker capabilities (reflected in "attacker profiles"). High risk attack paths, which correspond to those considered suited to application of attack countermeasures given limited resources for applying countermeasures, are identified by finding "epsilon optimal paths."
D’Haese, Pierre-François; Pallavaram, Srivatsan; Li, Rui; Remple, Michael S.; Kao, Chris; Neimat, Joseph S.; Konrad, Peter E.; Dawant, Benoit M.
2010-01-01
A number of methods have been developed to assist surgeons at various stages of deep brain stimulation (DBS) therapy. These include construction of anatomical atlases, functional databases, and electrophysiological atlases and maps. But, a complete system that can be integrated into the clinical workflow has not been developed. In this paper we present a system designed to assist physicians in pre-operative target planning, intra-operative target refinement and implantation, and post-operative DBS lead programming. The purpose of this system is to centralize the data acquired a the various stages of the procedure, reduce the amount of time needed at each stage of the therapy, and maximize the efficiency of the entire process. The system consists of a central repository (CranialVault), of a suite of software modules called CRAVE (CRAnialVault Explorer) that permit data entry and data visualization at each stage of the therapy, and of a series of algorithms that permit the automatic processing of the data. The central repository contains image data for more than 400 patients with the related pre-operative plans and position of the final implants and about 10,550 electrophysiological data points (micro-electrode recordings or responses to stimulations) recorded from 222 of these patients. The system has reached the stage of a clinical prototype that is being evaluated clinically at our institution. A preliminary quantitative validation of the planning component of the system performed on 80 patients who underwent the procedure between January 2009 and December 2009 shows that the system provides both timely and valuable information. PMID:20732828
Design and control of RUPERT: a device for robotic upper extremity repetitive therapy.
Sugar, Thomas G; He, Jiping; Koeneman, Edward J; Koeneman, James B; Herman, Richard; Huang, H; Schultz, Robert S; Herring, D E; Wanberg, J; Balasubramanian, Sivakumar; Swenson, Pete; Ward, Jeffrey A
2007-09-01
The structural design, control system, and integrated biofeedback for a wearable exoskeletal robot for upper extremity stroke rehabilitation are presented. Assisted with clinical evaluation, designers, engineers, and scientists have built a device for robotic assisted upper extremity repetitive therapy (RUPERT). Intense, repetitive physical rehabilitation has been shown to be beneficial overcoming upper extremity deficits, but the therapy is labor intensive and expensive and difficult to evaluate quantitatively and objectively. The RUPERT is developed to provide a low cost, safe and easy-to-use, robotic-device to assist the patient and therapist to achieve more systematic therapy at home or in the clinic. The RUPERT has four actuated degrees-of-freedom driven by compliant and safe pneumatic muscles (PMs) on the shoulder, elbow, and wrist. They are programmed to actuate the device to extend the arm and move the arm in 3-D space. It is very important to note that gravity is not compensated and the daily tasks are practiced in a natural setting. Because the device is wearable and lightweight to increase portability, it can be worn standing or sitting providing therapy tasks that better mimic activities of daily living. The sensors feed back position and force information for quantitative evaluation of task performance. The device can also provide real-time, objective assessment of functional improvement. We have tested the device on stroke survivors performing two critical activities of daily living (ADL): reaching out and self feeding. The future improvement of the device involves increased degrees-of-freedom and interactive control to adapt to a user's physical conditions.
Takushima, Akihiko; Harii, Kiyonori; Okazaki, Mutsumi; Ohura, Norihiko; Asato, Hirotaka
2009-04-01
Acute unilateral facial paralysis, such as occurs in Bell palsy and Hunt syndrome, is mostly a benign neurologic morbidity that resolves within a few months. However, incomplete or misdirected return of the affected nerve results in unfavorable cosmetic sequelae in some patients. Although functional problems such as lagophthalmos are rare, facial asymmetry on smiling resulting from a lack of mimetic muscle strength in the cheek is often psychologically annoying to patients. To obtain a more natural smile, the authors transfer latissimus dorsi muscle to assist in cheek movement. A small, thinned muscle (mini-latissimus dorsi) is sufficient for transplant in this situation. In this study, 96 patients with incomplete facial paralysis who underwent mini-latissimus dorsi transfer were examined. In this series, along with evaluation using the grading scale used in previous reports, preoperative and postoperative videos of 30 patients were analyzed for quantitative assessment using newly developed computer software. Temporary deterioration of paralysis was recognized in three cases but did not last more than a few months. Signs of transferred muscle contraction were recorded after 4 to 12 months among 91 patients. No apparent clinical signs of contraction were recognized in one patient, and four patients could not be followed postoperatively. The synchronized ratio of vertical movement and the symmetrical ratio of horizontal movement both in the cheek and in the lower lip between healthy and paralyzed sides among 30 patients were statistically improved. Statistical analysis using newly developed computer software revealed that a more symmetrical smile can be achieved by muscle transfer among patients with incomplete facial paralysis. Mini-latissimus dorsi transfer can avoid postoperative muscle bulkiness of the cheek and can achieve more natural cheek movement.
Computer-automated ABCD versus dermatologists with different degrees of experience in dermoscopy.
Piccolo, Domenico; Crisman, Giuliana; Schoinas, Spyridon; Altamura, Davide; Peris, Ketty
2014-01-01
Dermoscopy is a very useful and non-invasive technique for in vivo observation and preoperative diagnosis of pigmented skin lesions (PSLs) inasmuch as it enables analysis of surface and subsurface structures that are not discernible to the naked eye. The authors used the ABCD rule of dermoscopy to test the accuracy of melanoma diagnosis with respect to a panel of 165 PSLs and the intra- and inter-observer diagnostic agreement obtained between three dermatologists with different degrees of experience, one General Practitioner and a DDA for computer-assisted diagnosis (Nevuscreen(®), Arkè s.a.s., Avezzano, Italy). 165 Pigmented Skin Lesions from 165 patients were selected. Histopathological examination revealed 132 benign melanocytic skin lesions and 33 melanomas. The kappa statistic, sensitivity, specificity and predictive positive and negative values were calculated to measure agreement between all the human observers and in comparison with the automated DDA. Our results revealed poor reproducibility of the semi-quantitative algorithm devised by Stolz et al. independently of observers' experience in dermoscopy. Nevuscreen(®) (Arkè s.a.s., Avezzano, Italy) proved to be 'user friendly' to all observers, thus enabling a more critical evaluation of each lesion and representing a helpful tool for clinicians without significant experience in dermoscopy in improving and achieving more accurate diagnosis of PSLs.
NASA Technical Reports Server (NTRS)
Gillies, D. C.; Engel, H. P.
1999-01-01
Advances in x-ray Computer Tomography (CT) have been led by the medical profession, and by evaluation of industrial products, particularly castings. Porosity can readily be determined as a function of the density of a material, and CT is thus an industrially important NDE tool. Providing high purity, 100% dense standards of pure elements and compounds can be fabricated, the composition of solid solution alloys can be determined by measuring the CT number, which is a function of the absorption of the sample. Average densities across slices 1 mm thick can generally be determined to better than 1 percent. With present technology this spatial sensitivity is less than ideal, but important benefits can nevertheless be obtained by using CT, particularly single crystals, prior to making any destructive assault upon the sample. The sample can in fact be examined prior to removal from the mold within which it has been grown and, in the cases of microgravity flight samples, before removal from the cartridge assembly. This greatly assists the researcher in the characterization of the products, particularly as a guide to cutting and sampling. Examples of work with germanium-silicon alloys and mercury cadmium telluride taken with a radioactive cobalt source will be demonstrated.
The Application of Web-based Computer-assisted Instruction Courseware within Health Assessment
NASA Astrophysics Data System (ADS)
Xiuyan, Guo
Health assessment is a clinical nursing course and places emphasis on clinical skills. The application of computer-assisted instruction in the field of nursing teaching solved the problems in the traditional lecture class. This article stated teaching experience of web-based computer-assisted instruction, based upon a two-year study of computer-assisted instruction courseware use within the course health assessment. The computer-assisted instruction courseware could develop teaching structure, simulate clinical situations, create teaching situations and facilitate students study.
Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.
2013-01-01
The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted 1H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. PMID:23870106
NASA Astrophysics Data System (ADS)
Ge, Yuanzheng; Chen, Bin; liu, Liang; Qiu, Xiaogang; Song, Hongbin; Wang, Yong
2018-02-01
Individual-based computational environment provides an effective solution to study complex social events by reconstructing scenarios. Challenges remain in reconstructing the virtual scenarios and reproducing the complex evolution. In this paper, we propose a framework to reconstruct a synthetic computational environment, reproduce the epidemic outbreak, and evaluate management interventions in a virtual university. The reconstructed computational environment includes 4 fundamental components: the synthetic population, behavior algorithms, multiple social networks, and geographic campus environment. In the virtual university, influenza H1N1 transmission experiments are conducted, and gradually enhanced interventions are evaluated and compared quantitatively. The experiment results indicate that the reconstructed virtual environment provides a solution to reproduce complex emergencies and evaluate policies to be executed in the real world.
NASA Technical Reports Server (NTRS)
Pascucci, R. F.; Smith, A.
1982-01-01
To assist the U.S. Geological Survey in carrying out a Congressional mandate to investigate the use of side-looking airborne radar (SLAR) for resources exploration, a research program was conducted to define the contribution of SLAR imagery to structural geologic mapping and to compare this with contributions from other remote sensing systems. Imagery from two SLAR systems and from three other remote sensing systems was interpreted, and the resulting information was digitized, quantified and intercompared using a computer-assisted geographic information system (GIS). The study area covers approximately 10,000 square miles within the Naval Petroleum Reserve, Alaska, and is situated between the foothills of the Brooks Range and the North Slope. The principal objectives were: (1) to establish quantitatively, the total information contribution of each of the five remote sensing systems to the mapping of structural geology; (2) to determine the amount of information detected in common when the sensors are used in combination; and (3) to determine the amount of unique, incremental information detected by each sensor when used in combination with others. The remote sensor imagery that was investigated included real-aperture and synthetic-aperture radar imagery, standard and digitally enhanced LANDSAT MSS imagery, and aerial photos.
Agent-based modeling as a tool for program design and evaluation.
Lawlor, Jennifer A; McGirr, Sara
2017-12-01
Recently, systems thinking and systems science approaches have gained popularity in the field of evaluation; however, there has been relatively little exploration of how evaluators could use quantitative tools to assist in the implementation of systems approaches therein. The purpose of this paper is to explore potential uses of one such quantitative tool, agent-based modeling, in evaluation practice. To this end, we define agent-based modeling and offer potential uses for it in typical evaluation activities, including: engaging stakeholders, selecting an intervention, modeling program theory, setting performance targets, and interpreting evaluation results. We provide demonstrative examples from published agent-based modeling efforts both inside and outside the field of evaluation for each of the evaluative activities discussed. We further describe potential pitfalls of this tool and offer cautions for evaluators who may chose to implement it in their practice. Finally, the article concludes with a discussion of the future of agent-based modeling in evaluation practice and a call for more formal exploration of this tool as well as other approaches to simulation modeling in the field. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsuchiya, Yuichiro; Kodera, Yoshie; Tanaka, Rie; Sanada, Shigeru
2007-03-01
Early detection and treatment of lung cancer is one of the most effective means to reduce cancer mortality; chest X-ray radiography has been widely used as a screening examination or health checkup. The new examination method and the development of computer analysis system allow obtaining respiratory kinetics by the use of flat panel detector (FPD), which is the expanded method of chest X-ray radiography. Through such changes functional evaluation of respiratory kinetics in chest has become available. Its introduction into clinical practice is expected in the future. In this study, we developed the computer analysis algorithm for the purpose of detecting lung nodules and evaluating quantitative kinetics. Breathing chest radiograph obtained by modified FPD was converted into 4 static images drawing the feature, by sequential temporal subtraction processing, morphologic enhancement processing, kinetic visualization processing, and lung region detection processing, after the breath synchronization process utilizing the diaphragmatic analysis of the vector movement. The artificial neural network used to analyze the density patterns detected the true nodules by analyzing these static images, and drew their kinetic tracks. For the algorithm performance and the evaluation of clinical effectiveness with 7 normal patients and simulated nodules, both showed sufficient detecting capability and kinetic imaging function without statistically significant difference. Our technique can quantitatively evaluate the kinetic range of nodules, and is effective in detecting a nodule on a breathing chest radiograph. Moreover, the application of this technique is expected to extend computer-aided diagnosis systems and facilitate the development of an automatic planning system for radiation therapy.
Campbell, Aimee N C; Nunes, Edward V; Miele, Gloria M; Matthews, Abigail; Polsky, Daniel; Ghitza, Udi E; Turrigiano, Eva; Bailey, Genie L; VanVeldhuisen, Paul; Chapdelaine, Rita; Froias, Autumn; Stitzer, Maxine L; Carroll, Kathleen M; Winhusen, Theresa; Clingerman, Sara; Perez, Livangelie; McClure, Erin; Goldman, Bruce; Crowell, A Rebecca
2012-03-01
Computer-assisted interventions hold the promise of minimizing two problems that are ubiquitous in substance abuse treatment: the lack of ready access to treatment and the challenges to providing empirically-supported treatments. Reviews of research on computer-assisted treatments for mental health and substance abuse report promising findings, but study quality and methodological limitations remain an issue. In addition, relatively few computer-assisted treatments have been tested among illicit substance users. This manuscript describes the methodological considerations of a multi-site effectiveness trial conducted within the National Institute on Drug Abuse's (NIDA's) National Drug Abuse Treatment Clinical Trials Network (CTN). The study is evaluating a web-based version of the Community Reinforcement Approach, in addition to prize-based contingency management, among 500 participants enrolled in 10 outpatient substance abuse treatment programs. Several potential effectiveness trial designs were considered and the rationale for the choice of design in this study is described. The study uses a randomized controlled design (with independent treatment arm allocation), intention-to-treat primary outcome analysis, biological markers for the primary outcome of abstinence, long-term follow-up assessments, precise measurement of intervention dose, and a cost-effectiveness analysis. Input from community providers during protocol development highlighted potential concerns and helped to address issues of practicality and feasibility. Collaboration between providers and investigators supports the utility of infrastructures that enhance research partnerships to facilitate effectiveness trials and dissemination of promising, technologically innovative treatments. Outcomes from this study will further the empirical knowledge base on the effectiveness and cost-effectiveness of computer-assisted treatment in clinical treatment settings. Copyright © 2011 Elsevier Inc. All rights reserved.
Campbell, Aimee N. C.; Nunes, Edward V.; Miele, Gloria M.; Matthews, Abigail; Polsky, Daniel; Ghitza, Udi E.; Turrigiano, Eva; Bailey, Genie L.; VanVeldhuisen, Paul; Chapdelaine, Rita; Froias, Autumn; Stitzer, Maxine L.; Carroll, Kathleen M.; Winhusen, Theresa; Clingerman, Sara; Perez, Livangelie; McClure, Erin; Goldman, Bruce; Crowell, A. Rebecca
2011-01-01
Computer-assisted interventions hold the promise of minimizing two problems that are ubiquitous in substance abuse treatment: the lack of ready access to treatment and the challenges to providing empirically-supported treatments. Reviews of research on computer-assisted treatments for mental health and substance abuse report promising findings, but study quality and methodological limitations remain an issue. In addition, relatively few computer-assisted treatments have been tested among illicit substance users. This manuscript describes the methodological considerations of a multi-site effectiveness trial conducted within the National Institute on Drug Abuse's (NIDA's) National Drug Abuse Treatment Clinical Trials Network (CTN). The study is evaluating a web-based version of the Community Reinforcement Approach, in addition to prize-based contingency management, among 500 participants enrolled in 10 outpatient substance abuse treatment programs. Several potential effectiveness trial designs were considered and the rationale for the choice of design in this study is described. The study uses a randomized controlled design (with independent treatment arm allocation), intention-to-treat primary outcome analysis, biological markers for the primary outcome of abstinence, long-term follow-up assessments, precise measurement of intervention dose, and a cost-effectiveness analysis. Input from community providers during protocol development highlighted potential concerns and helped to address issues of practicality and feasibility. Collaboration between providers and investigators supports the utility of infrastructures that enhance research partnerships to facilitate effectiveness trials and dissemination of promising, technologically innovative treatments. Outcomes from this study will further the empirical knowledge base on the effectiveness and cost-effectiveness of computer-assisted treatment in clinical treatment settings. PMID:22085803
Iyatomi, Hitoshi; Oka, Hiroshi; Saito, Masataka; Miyake, Ayako; Kimoto, Masayuki; Yamagami, Jun; Kobayashi, Seiichiro; Tanikawa, Akiko; Hagiwara, Masafumi; Ogawa, Koichi; Argenziano, Giuseppe; Soyer, H Peter; Tanaka, Masaru
2006-04-01
The aims of this study were to provide a quantitative assessment of the tumour area extracted by dermatologists and to evaluate computer-based methods from dermoscopy images for refining a computer-based melanoma diagnostic system. Dermoscopic images of 188 Clark naevi, 56 Reed naevi and 75 melanomas were examined. Five dermatologists manually drew the border of each lesion with a tablet computer. The inter-observer variability was evaluated and the standard tumour area (STA) for each dermoscopy image was defined. Manual extractions by 10 non-medical individuals and by two computer-based methods were evaluated with STA-based assessment criteria: precision and recall. Our new computer-based method introduced the region-growing approach in order to yield results close to those obtained by dermatologists. The effectiveness of our extraction method with regard to diagnostic accuracy was evaluated. Two linear classifiers were built using the results of conventional and new computer-based tumour area extraction methods. The final diagnostic accuracy was evaluated by drawing the receiver operating curve (ROC) of each classifier, and the area under each ROC was evaluated. The standard deviations of the tumour area extracted by five dermatologists and 10 non-medical individuals were 8.9% and 10.7%, respectively. After assessment of the extraction results by dermatologists, the STA was defined as the area that was selected by more than two dermatologists. Dermatologists selected the melanoma area with statistically smaller divergence than that of Clark naevus or Reed naevus (P = 0.05). By contrast, non-medical individuals did not show this difference. Our new computer-based extraction algorithm showed superior performance (precision, 94.1%; recall, 95.3%) to the conventional thresholding method (precision, 99.5%; recall, 87.6%). These results indicate that our new algorithm extracted a tumour area close to that obtained by dermatologists and, in particular, the border part of the tumour was adequately extracted. With this refinement, the area under the ROC increased from 0.795 to 0.875 and the diagnostic accuracy showed an increase of approximately 20% in specificity when the sensitivity was 80%. It can be concluded that our computer-based tumour extraction algorithm extracted almost the same area as that obtained by dermatologists and provided improved computer-based diagnostic accuracy.
ERIC Educational Resources Information Center
Wood, Richard J.
The computer program described is written in BASIC and, although it was developed for use at Slippery Rock State College, it could be adapted easily for other libraries using Library of Congress classification and cataloging rules. The program uses simple sequences of instructions and explanations followed by questions. Branching is employed to…
ERIC Educational Resources Information Center
Mallios, Nikolaos; Vassilakopoulos, Michael Gr.
2015-01-01
One of the most intriguing objectives when teaching computer science in mid-adolescence high school students is attracting and mainly maintaining their concentration within the limits of the class. A number of theories have been proposed and numerous methodologies have been applied, aiming to assist in the implementation of a personalized learning…
ERIC Educational Resources Information Center
Wilkerson, Joyce A.; Elkins, Susan A.
This qualitative case study assessed web-based instruction in a computer-aided design/computer-assisted manufacturing (CAD/CAM) course designed for workforce development. The study examined students' and instructors' experience in a CAD/CAM course delivered exclusively on the Internet, evaluating course content and delivery, clarity of…
ERIC Educational Resources Information Center
Roy, Jon F.
2016-01-01
This study examined the effectiveness of READ 180, a computer based reading intervention on Lexile reading levels, Standardized Test of Reading Achievement (STAR) score, and attendance rates students in grades 3-5 who participated in the READ 180 program. The study compared the Scholastic Reading Inventory (SRI) scores of each group administered…
ERIC Educational Resources Information Center
Mikulecky, Larry
A study evaluated the effectiveness of a series of print materials and interactive computer-guided study programs designed to lead undergraduate students to apply basic textbook reading and concept mapping strategies to the study of science and social science textbooks. Following field testing with 25 learning skills students, 50 freshman biology…
ERIC Educational Resources Information Center
Rehberg, Robb S.; Gazzillo Diaz, Linda; Middlemas, David A.
2009-01-01
Objective: The objective of this study was to determine whether computer-based CPR training is comparable to traditional classroom training. Design and Setting: This study was quantitative in design. Data was gathered from a standardized examination and skill performance evaluation which yielded numerical scores. Subjects: The subjects were 64…
Design Principles for Computer-Assisted Instruction in Histology Education: An Exploratory Study
ERIC Educational Resources Information Center
Deniz, Hasan; Cakir, Hasan
2006-01-01
The purpose of this paper is to describe the development process and the key components of a computer-assisted histology material. Computer-assisted histology material is designed to supplement traditional histology education in a large Midwestern university. Usability information of the computer-assisted instruction (CAI) material was obtained…
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment under... FINANCIAL ASSISTANCE PROGRAMS § 233.35 Computing the assistance payment under retrospective budgeting after... shall be computed retrospectively, i.e., shall be based on income and other relevant circumstances in...
ERIC Educational Resources Information Center
Shih, Ching-Hsiang
2011-01-01
This study evaluated whether two people with multiple disabilities and minimal motor behavior would be able to improve their Drag-and-Drop (DnD) performance using their finger/thumb poke ability with a mouse scroll wheel through a Dynamic Drag-and-Drop Assistive Program (DDnDAP). A multiple probe design across participants was used in this study…
An intelligent interface for satellite operations: Your Orbit Determination Assistant (YODA)
NASA Technical Reports Server (NTRS)
Schur, Anne
1988-01-01
An intelligent interface is often characterized by the ability to adapt evaluation criteria as the environment and user goals change. Some factors that impact these adaptations are redefinition of task goals and, hence, user requirements; time criticality; and system status. To implement adaptations affected by these factors, a new set of capabilities must be incorporated into the human-computer interface design. These capabilities include: (1) dynamic update and removal of control states based on user inputs, (2) generation and removal of logical dependencies as change occurs, (3) uniform and smooth interfacing to numerous processes, databases, and expert systems, and (4) unobtrusive on-line assistance to users of concepts were applied and incorporated into a human-computer interface using artificial intelligence techniques to create a prototype expert system, Your Orbit Determination Assistant (YODA). YODA is a smart interface that supports, in real teime, orbit analysts who must determine the location of a satellite during the station acquisition phase of a mission. Also described is the integration of four knowledge sources required to support the orbit determination assistant: orbital mechanics, spacecraft specifications, characteristics of the mission support software, and orbit analyst experience. This initial effort is continuing with expansion of YODA's capabilities, including evaluation of results of the orbit determination task.
Vehicle - Bridge interaction, comparison of two computing models
NASA Astrophysics Data System (ADS)
Melcer, Jozef; Kuchárová, Daniela
2017-07-01
The paper presents the calculation of the bridge response on the effect of moving vehicle moves along the bridge with various velocities. The multi-body plane computing model of vehicle is adopted. The bridge computing models are created in two variants. One computing model represents the bridge as the Bernoulli-Euler beam with continuously distributed mass and the second one represents the bridge as the lumped mass model with 1 degrees of freedom. The mid-span bridge dynamic deflections are calculated for both computing models. The results are mutually compared and quantitative evaluated.
Jacobs, Bob; Johnson, Nicholas L.; Wahl, Devin; Schall, Matthew; Maseko, Busisiwe C.; Lewandowski, Albert; Raghanti, Mary A.; Wicinski, Bridget; Butti, Camilla; Hopkins, William D.; Bertelsen, Mads F.; Walsh, Timothy; Roberts, John R.; Reep, Roger L.; Hof, Patrick R.; Sherwood, Chet C.; Manger, Paul R.
2014-01-01
Although the basic morphological characteristics of neurons in the cerebellar cortex have been documented in several species, virtually nothing is known about the quantitative morphological characteristics of these neurons across different taxa. To that end, the present study investigated cerebellar neuronal morphology among eight different, large-brained mammalian species comprising a broad phylogenetic range: afrotherians (African elephant, Florida manatee), carnivores (Siberian tiger, clouded leopard), cetartiodactyls (humpback whale, giraffe) and primates (human, common chimpanzee). Specifically, several neuron types (e.g., stellate, basket, Lugaro, Golgi, and granule neurons; N = 317) of the cerebellar cortex were stained with a modified rapid Golgi technique and quantified on a computer-assisted microscopy system. There was a 64-fold variation in brain mass across species in our sample (from clouded leopard to the elephant) and a 103-fold variation in cerebellar volume. Most dendritic measures tended to increase with cerebellar volume. The cerebellar cortex in these species exhibited the trilaminate pattern common to all mammals. Morphologically, neuron types in the cerebellar cortex were generally consistent with those described in primates (Fox et al., 1967) and rodents (Palay and Chan-Palay, 1974), although there was substantial quantitative variation across species. In particular, Lugaro neurons in the elephant appeared to be disproportionately larger than those in other species. To explore potential quantitative differences in dendritic measures across species, MARSplines analyses were used to evaluate whether species could be differentiated from each other based on dendritic characteristics alone. Results of these analyses indicated that there were significant differences among all species in dendritic measures. PMID:24795574
A Cognitive Computing Approach for Classification of Complaints in the Insurance Industry
NASA Astrophysics Data System (ADS)
Forster, J.; Entrup, B.
2017-10-01
In this paper we present and evaluate a cognitive computing approach for classification of dissatisfaction and four complaint specific complaint classes in correspondence documents between insurance clients and an insurance company. A cognitive computing approach includes the combination classical natural language processing methods, machine learning algorithms and the evaluation of hypothesis. The approach combines a MaxEnt machine learning algorithm with language modelling, tf-idf and sentiment analytics to create a multi-label text classification model. The result is trained and tested with a set of 2500 original insurance communication documents written in German, which have been manually annotated by the partnering insurance company. With a F1-Score of 0.9, a reliable text classification component has been implemented and evaluated. A final outlook towards a cognitive computing insurance assistant is given in the end.
EVALUATION OF PHYSIOLOGY COMPUTER MODELS, AND THE FEASIBILITY OF THEIR USE IN RISK ASSESSMENT.
This project will evaluate the current state of quantitative models that simulate physiological processes, and the how these models might be used in conjunction with the current use of PBPK and BBDR models in risk assessment. The work will include a literature search to identify...
Object-Oriented Algorithm For Evaluation Of Fault Trees
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Koen, B. V.
1992-01-01
Algorithm for direct evaluation of fault trees incorporates techniques of object-oriented programming. Reduces number of calls needed to solve trees with repeated events. Provides significantly improved software environment for such computations as quantitative analyses of safety and reliability of complicated systems of equipment (e.g., spacecraft or factories).
Computer Assisted Instruction in Teacher Education: A Full Length Course.
ERIC Educational Resources Information Center
Cartwright, G. Phillip
Pennsylvania State University has developed, evaluated, and implemented a series of modules and an entire three-credit teacher education course which is offered completely by microcomputer. The course is entitled "Educating Special Learners." The modules use the Apple II series and the IBM PC series. Evaluation of the course, based on…
A Group-Decision Approach for Evaluating Educational Web Sites
ERIC Educational Resources Information Center
Hwang, Gwo-Jen; Huanga, Tony C. K.; Tseng, Judy C. R.
2004-01-01
With the advent of network technologies, many educational web sites have been developed to assist students in the learning of subjects on computer networks. However, without proper aid, students may have difficulty in selecting appropriate web sites, that are of benefit to them; hence, studying, evaluating and recommending educational web sites…
Evaluating a Web-Based Video Corpus through an Analysis of User Interactions
ERIC Educational Resources Information Center
Caws, Catherine G.
2013-01-01
As shown by several studies, successful integration of technology in language learning requires a holistic approach in order to scientifically understand what learners do when working with web-based technology (cf. Raby, 2007). Additionally, a growing body of research in computer assisted language learning (CALL) evaluation, design and…
Historical review of computer-assisted cognitive retraining.
Lynch, Bill
2002-10-01
This article details the introduction and development of the use of microcomputers as adjuncts to traditional cognitive rehabilitation of persons with acquired brain injury. The initial application of video games as therapeutic recreation in the late 1970s was soon followed in the early 1980s by the use of the first personal computers and available educational software. By the mid-1980s, both the IBM PC and Macintosh platforms were established, along with simplified programming languages that allowed individuals without extensive technical expertise to develop their own software. Several rehabilitation clinicians began to produce and market specially written cognitive retraining software for one or the other platform. Their work was detailed and reviewed, as was recently released software from commercial sources. The latter discussion included the latest developments in the rehabilitation applications of personal digital assistants and related organizing, reminding, and dictation devices. A summary of research on the general and specific efficacy of computer-assisted cognitive retraining illustrated the lingering controversy and skepticism that have been associated with this field since its inception. Computer-assisted cognitive retraining (CACR) can be an effective adjunct to a comprehensive program of cognitive rehabilitation. Training needs to be focused, structured, monitored, and as ecologically relevant as possible for optimum effect. Transfer or training or generalizability of skills remains a key issue in the field and should be considered the key criterion in evaluating whether to initiate or continue CACR.
Analyzing Robotic Kinematics Via Computed Simulations
NASA Technical Reports Server (NTRS)
Carnahan, Timothy M.
1992-01-01
Computing system assists in evaluation of kinematics of conceptual robot. Displays positions and motions of robotic manipulator within work cell. Also displays interactions between robotic manipulator and other objects. Results of simulation displayed on graphical computer workstation. System includes both off-the-shelf software originally developed for automotive industry and specially developed software. Simulation system also used to design human-equivalent hand, to model optical train in infrared system, and to develop graphical interface for teleoperator simulation system.
Safe Passage Data Analysis: Interim Report
DOT National Transportation Integrated Search
1993-04-01
The purpose of this report is to describe quantitatively the costs and benefits of screener : proficiency evaluation and reporting systems (SPEARS) equipment, particularly computer-based : instruction (CBI) systems, compared to current methods of tra...
Assis, Sofia; Costa, Pedro; Rosas, Maria Jose; Vaz, Rui; Silva Cunha, Joao Paulo
2016-08-01
Intraoperative evaluation of the efficacy of Deep Brain Stimulation includes evaluation of the effect on rigidity. A subjective semi-quantitative scale is used, dependent on the examiner perception and experience. A system was proposed previously, aiming to tackle this subjectivity, using quantitative data and providing real-time feedback of the computed rigidity reduction, hence supporting the physician decision. This system comprised of a gyroscope-based motion sensor in a textile band, placed in the patients hand, which communicated its measurements to a laptop. The latter computed a signal descriptor from the angular velocity of the hand during wrist flexion in DBS surgery. The first approach relied on using a general rigidity reduction model, regardless of the initial severity of the symptom. Thus, to enhance the performance of the previously presented system, we aimed to develop models for high and low baseline rigidity, according to the examiner assessment before any stimulation. This would allow a more patient-oriented approach. Additionally, usability was improved by having in situ processing in a smartphone, instead of a computer. Such system has shown to be reliable, presenting an accuracy of 82.0% and a mean error of 3.4%. Relatively to previous results, the performance was similar, further supporting the importance of considering the cogwheel rigidity to better infer about the reduction in rigidity. Overall, we present a simple, wearable, mobile system, suitable for intra-operatory conditions during DBS, supporting a physician in decision-making when setting stimulation parameters.
NASA Astrophysics Data System (ADS)
Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.; Lerallut, Jean-Francois
2006-03-01
Pulmonary diseases such as bronchiectasis, asthma, and emphysema are characterized by abnormalities in airway dimensions. Multi-slice computed tomography (MSCT) has become one of the primary means to depict these abnormalities, as the availability of high-resolution near-isotropic data makes it possible to evaluate airways at oblique angles to the scanner plane. However, currently, clinical evaluation of airways is typically limited to subjective visual inspection only: systematic evaluation of the airways to take advantage of high-resolution data has not proved practical without automation. We present an automated method to quantitatively evaluate airway lumen diameter, wall thickness and broncho-arterial ratios. In addition, our method provides 3D visualization of these values, graphically illustrating the location and extent of disease. Our algorithm begins by automatic airway segmentation to extract paths to the distal airways, and to create a map of airway diameters. Normally, airway diameters decrease as paths progress distally; failure to taper indicates abnormal dilatation. Our approach monitors airway lumen diameters along each airway path in order to detect abnormal profiles, allowing even subtle degrees of pathologic dilatation to be identified. Our method also systematically computes the broncho-arterial ratio at every terminal branch of the tree model, as a ratio above 1 indicates potentially abnormal bronchial dilatation. Finally, the airway wall thickness is computed at corresponding locations. These measurements are used to highlight abnormal branches for closer inspection, and can be summed to compute a quantitative global score for the entire airway tree, allowing reproducible longitudinal assessment of disease severity. Preliminary tests on patients diagnosed with bronchiectasis demonstrated rapid identification of lack of tapering, which also was confirmed by corresponding demonstration of elevated broncho-arterial ratios.
Prescott, Jeffrey William
2013-02-01
The importance of medical imaging for clinical decision making has been steadily increasing over the last four decades. Recently, there has also been an emphasis on medical imaging for preclinical decision making, i.e., for use in pharamaceutical and medical device development. There is also a drive towards quantification of imaging findings by using quantitative imaging biomarkers, which can improve sensitivity, specificity, accuracy and reproducibility of imaged characteristics used for diagnostic and therapeutic decisions. An important component of the discovery, characterization, validation and application of quantitative imaging biomarkers is the extraction of information and meaning from images through image processing and subsequent analysis. However, many advanced image processing and analysis methods are not applied directly to questions of clinical interest, i.e., for diagnostic and therapeutic decision making, which is a consideration that should be closely linked to the development of such algorithms. This article is meant to address these concerns. First, quantitative imaging biomarkers are introduced by providing definitions and concepts. Then, potential applications of advanced image processing and analysis to areas of quantitative imaging biomarker research are described; specifically, research into osteoarthritis (OA), Alzheimer's disease (AD) and cancer is presented. Then, challenges in quantitative imaging biomarker research are discussed. Finally, a conceptual framework for integrating clinical and preclinical considerations into the development of quantitative imaging biomarkers and their computer-assisted methods of extraction is presented.
Nadjmi, Nasser; Defrancq, Ellen; Mollemans, Wouter; Hemelen, Geert Van; Bergé, Stefaan
2014-01-01
The aim of this study was to evaluate the accuracy of 3D soft tissue predictions generated by a computer-aided maxillofacial planning system in patients undergoing orthognathic surgery. Twenty patients with dentofacial dysmorphosis were treated with orthognathic surgery after a preoperative orthodontic treatment. Fourteen patients had an Angle Class II malocclusion; three patients had an Angle class III malocclusion, and three patients had an Angle Class I malocclusion. Skeletal asymmetry was observed in six patient. The surgeries were planned using the Maxilim software. Computer assisted surgical planning was transferred to the patient by digitally generated splints. The validation procedures were performed in the following steps: (1) Standardized registration of the pre- and postoperative Cone Beam CT volumes; (2) Automated adjustment of the bone-related planning to the actual operative bony displacement; (3) Simulation of soft tissue changes; (4) Calculation of the soft tissue differences between the predicted and the postoperative results by distance mapping. Eighty four percent of the mapped distances between the predicted and actual postoperative results measured between -2 mm and +2 mm. The mean absolute linear measurements between the predicted and actual postoperative surface was 1.18. Our study shows the overall prediction was dependent on neither the surgical procedures nor the dentofacial deformity type. Despite some shortcomings in the prediction of the final position of the lower lip and cheek area, this software promises a clinically acceptable soft tissue prediction for orthognathic surgical procedures.
Zapotoczny, Piotr; Kozera, Wojciech; Karpiesiuk, Krzysztof; Pawłowski, Rodian
2014-08-01
The effect of management systems on selected physical properties and chemical composition of m. longissimus dorsi was studied in pigs. Muscle texture parameters were determined by computer-assisted image analysis, and the color of muscle samples was evaluated using a spectrophotometer. Highly significant correlations were observed between chemical composition and selected texture variables in the analyzed images. Chemical composition was not correlated with color or spectral distribution. Subject to the applied classification methods and groups of variables included in the classification model, the experimental groups were identified correctly in 35-95%. No significant differences in the chemical composition of m. longissimus dorsi were observed between experimental groups. Significant differences were noted in color lightness (L*) and redness (a*). Copyright © 2014 Elsevier Ltd. All rights reserved.
Effect of Computer-Assisted Learning on Students' Dental Anatomy Waxing Performance.
Kwon, So Ran; Hernández, Marcela; Blanchette, Derek R; Lam, Matthew T; Gratton, David G; Aquilino, Steven A
2015-09-01
The aim of this study was to evaluate the impact of computer-assisted learning on first-year dental students' waxing abilities and self-evaluation skills. Additionally, this study sought to determine how well digital evaluation software performed compared to faculty grading with respect to students' technical scores on a practical competency examination. First-year students at one U.S. dental school were assigned to one of three groups: control (n=40), E4D Compare (n=20), and Sirona prepCheck (n=19). Students in the control group were taught by traditional teaching methodologies, and the technology-assisted groups received both traditional training and supplementary feedback from the corresponding digital system. Five outcomes were measured: visual assessment score, self-evaluation score, and digital assessment scores at 0.25 mm, 0.30 mm, and 0.35 mm tolerance. The scores from visual assessment and self-evaluation were examined for differences among groups using the Kruskal-Wallis test. Correlation between the visual assessment and digital scores was measured using Pearson and Spearman rank correlation coefficients. At completion of the course, students were asked to complete a survey on the use of these digital technologies. All 79 students in the first-year class participated in the study, for a 100% response rate. The results showed that the visual assessment and self-evaluation scores did not differ among groups (p>0.05). Overall correlations between visual and digital assessment scores were modest though statistically significant (5% level of significance). Analysis of survey responses completed by students in the technology groups showed that profiles for the two groups were similar and not favorable towards digital technology. The study concluded that technology-assisted training did not affect these students' waxing performance or self-evaluation skills and that visual scores given by faculty and digital assessment scores correlated moderately.
Caruso, Maria Vittoria; Gramigna, Vera; Renzulli, Attilio; Fragomeni, Gionata
2016-01-01
The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. Partial support is hemodynamically advisable.
Using the Computer in Special Vocational Programs. Inservice Activities.
ERIC Educational Resources Information Center
Lane, Kenneth; Ward, Raymond
This inservice manual is intended to assist vocational education teachers in using the techniques of computer-assisted instruction in special vocational education programs. Addressed in the individual units are the following topics: the basic principles of computer-assisted instruction (TRS-80 computers and typing on a computer keyboard); money…
ERIC Educational Resources Information Center
Gambari, Isiaka A.; Gbodi, Bimpe E.; Olakanmi, Eyitao U.; Abalaka, Eneojo N.
2016-01-01
The role of computer-assisted instruction in promoting intrinsic and extrinsic motivation among Nigerian secondary school chemistry students was investigated in this study. The study employed two modes of computer-assisted instruction (computer simulation instruction and computer tutorial instructional packages) and two levels of gender (male and…
ERIC Educational Resources Information Center
Menassa, Carol Chukri
2009-01-01
A project-specific dispute resolution ladder (DRL) typically consists of multiple alternative dispute resolution (ADR) techniques that are chosen to assist in mitigating the impact of change orders and claims (CCO) occurring during the project construction phase, and avoid their escalation to protracted disputes that adversely affect a…
Mari, João Fernando; Saito, José Hiroki; Neves, Amanda Ferreira; Lotufo, Celina Monteiro da Cruz; Destro-Filho, João-Batista; Nicoletti, Maria do Carmo
2015-12-01
Microelectrode Arrays (MEA) are devices for long term electrophysiological recording of extracellular spontaneous or evocated activities on in vitro neuron culture. This work proposes and develops a framework for quantitative and morphological analysis of neuron cultures on MEAs, by processing their corresponding images, acquired by fluorescence microscopy. The neurons are segmented from the fluorescence channel images using a combination of segmentation by thresholding, watershed transform, and object classification. The positioning of microelectrodes is obtained from the transmitted light channel images using the circular Hough transform. The proposed method was applied to images of dissociated culture of rat dorsal root ganglion (DRG) neuronal cells. The morphological and topological quantitative analysis carried out produced information regarding the state of culture, such as population count, neuron-to-neuron and neuron-to-microelectrode distances, soma morphologies, neuron sizes, neuron and microelectrode spatial distributions. Most of the analysis of microscopy images taken from neuronal cultures on MEA only consider simple qualitative analysis. Also, the proposed framework aims to standardize the image processing and to compute quantitative useful measures for integrated image-signal studies and further computational simulations. As results show, the implemented microelectrode identification method is robust and so are the implemented neuron segmentation and classification one (with a correct segmentation rate up to 84%). The quantitative information retrieved by the method is highly relevant to assist the integrated signal-image study of recorded electrophysiological signals as well as the physical aspects of the neuron culture on MEA. Although the experiments deal with DRG cell images, cortical and hippocampal cell images could also be processed with small adjustments in the image processing parameter estimation.
Development and Implementation of a Design Metric for Systems Containing Long-Term Fluid Loops
NASA Technical Reports Server (NTRS)
Steele, John W.
2016-01-01
John Steele, a chemist and technical fellow from United Technologies Corporation, provided a water quality module to assist engineers and scientists with a metric tool to evaluate risks associated with the design of space systems with fluid loops. This design metric is a methodical, quantitative, lessons-learned based means to evaluate the robustness of a long-term fluid loop system design. The tool was developed by a cross-section of engineering disciplines who had decades of experience and problem resolution.
The Basic Shelf Experience: a comprehensive evaluation.
Dewolfe, Judith A; Greaves, Gaye
2003-01-01
The Basic Shelf Experience is a program designed to assist people living on limited incomes to make better use of their food resources. The purpose of this research was to learn if the Basic Shelf Experience program helps such people to 1. utilize food resources more effectively and 2. cope, through group support, with poverty-associated stressors that influence food security. Both quantitative and qualitative methods were used to evaluate the program objectives. Participants completed a questionnaire at the beginning and end of the six-week program. The questionnaire asked about their food access, food security, and feelings about themselves. Participants returned for a focus group discussion and completed the questionnaire again three months after the program ended. The focus group was designed to elicit information about perceived changes, if any, attributed to the program. Forty-two people completed the questionnaires pre-program and 20 post-program; 17 participated in the three-month follow-up session. While results from quantitative data analysis indicate that program objectives were not met, qualitative data provide evidence that the program did achieve its stated objectives. Our results suggest such programs as the Basic Shelf Experience can assist people living on limited incomes to achieve food security.
Andersson, Magnus; Lantz, Jonas; Ebbers, Tino; Karlsson, Matts
2015-09-01
Turbulence and flow eccentricity can be measured by magnetic resonance imaging (MRI) and may play an important role in the pathogenesis of numerous cardiovascular diseases. In the present study, we propose quantitative techniques to assess turbulent kinetic energy (TKE) and flow eccentricity that could assist in the evaluation and treatment of stenotic severities. These hemodynamic parameters were studied in a pre-treated aortic coarctation (CoA) and after several virtual interventions using computational fluid dynamics (CFD), to demonstrate the effect of different dilatation options on the flow field. Patient-specific geometry and flow conditions were derived from MRI data. The unsteady pulsatile flow was resolved by large eddy simulation including non-Newtonian blood rheology. Results showed an inverse asymptotic relationship between the total amount of TKE and degree of dilatation of the stenosis, where turbulent flow proximal the constriction limits the possible improvement by treating the CoA alone. Spatiotemporal maps of TKE and flow eccentricity could be linked to the characteristics of the jet, where improved flow conditions were favored by an eccentric dilatation of the CoA. By including these flow markers into a combined MRI-CFD intervention framework, CoA therapy has not only the possibility to produce predictions via simulation, but can also be validated pre- and immediate post treatment, as well as during follow-up studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bunce, O.R.; Badary, O.A.; Abou El-Ela, S.
1991-03-15
Adrenal cortical hormones suppress initiation and promotion of DMBA-induced mammary tumorigenesis. The authors found a positive correlation between presence of DMBA-induced adrenal cortical necrosis and mammary tumor incidence. Because they find adrenal medullary as well as cortical lesions in tumor bearing (TB) DMBA-treated rats, they evaluated medullary function by quantitating hybridized cDNA- TH-S{sup 35} with in situ TH-mRNA u sing computer assisted quantitative autoradiographic technique. Virgin female Sprague-Dawley rats were given a 10 mg i.g. dose of DMBA. Three wks later, rats were placed on 20% polyunsaturated (PUFA) fat diets containing omega-6 and omega-3 fatty acids. All were killed 15more » wks post-DMBA. TH-mRNA levels in adrenal medullae of TB animals were decreased compared to non-TB rats. Histopathology indicated a high incidence of medullary necrosis in TB rats, whereas, adrenal necrosis did not occur in non-TB animals. Adrenal necrosis correlated positively with tumor burden, but no correlation was found between incidence of adrenal lesions and type of PUFA in the diet. The authors suggest that DMBA adrenal necrosis may reduce TH-mRNA in the medulla, compromise its catecholamine synthetic capability, and thereby contribute to the overall metabolic stress condition of TB rats.« less
Barkovskaya, M Sh; Bogomolov, A G; Knauer, N Yu; Rubtsov, N B; Kozlov, V A
2017-04-01
Telomere length is an important indicator of proliferative cell history and potential. Decreasing telomere length in the cells of an immune system can indicate immune aging in immune-mediated and chronic inflammatory diseases. Quantitative fluorescent in situ hybridization (Q-FISH) of a labeled (C 3 TA[Formula: see text] peptide nucleic acid probe onto fixed metaphase cells followed by digital image microscopy allows the evaluation of telomere length in the arms of individual chromosomes. Computer-assisted analysis of microscopic images can provide quantitative information on the number of telomeric repeats in individual telomeres. We developed new software to estimate telomere length. The MeTeLen software contains new options that can be used to solve some Q-FISH and microscopy problems, including correction of irregular light effects and elimination of background fluorescence. The identification and description of chromosomes and chromosome regions are essential to the Q-FISH technique. To improve the quality of cytogenetic analysis after Q-FISH, we optimized the temperature and time of DNA-denaturation to get better DAPI-banding of metaphase chromosomes. MeTeLen was tested by comparing telomere length estimations for sister chromatids, background fluorescence estimations, and correction of nonuniform light effects. The application of the developed software for analysis of telomere length in patients with rheumatoid arthritis was demonstrated.
Nondestructive Evaluation for Aerospace Composites
NASA Technical Reports Server (NTRS)
Leckey, Cara; Cramer, Elliott; Perey, Daniel
2015-01-01
Nondestructive evaluation (NDE) techniques are important for enabling NASA's missions in space exploration and aeronautics. The expanded and continued use of composite materials for aerospace components and vehicles leads to a need for advanced NDE techniques capable of quantitatively characterizing damage in composites. Quantitative damage detection techniques help to ensure safety, reliability and durability of space and aeronautic vehicles. This presentation will give a broad outline of NASA's range of technical work and an overview of the NDE research performed in the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center. The presentation will focus on ongoing research in the development of NDE techniques for composite materials and structures, including development of automated data processing tools to turn NDE data into quantitative location and sizing results. Composites focused NDE research in the areas of ultrasonics, thermography, X-ray computed tomography, and NDE modeling will be discussed.
Jha, Abhinav K; Caffo, Brian; Frey, Eric C
2016-01-01
The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation. PMID:26982626
Jha, Abhinav K; Caffo, Brian; Frey, Eric C
2016-04-07
The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation.
A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries.
Klein, J L; Hoff, J G; Peifer, J W; Folks, R; Cooke, C D; King, S B; Garcia, E V
1998-04-01
Through extensive training and experience angiographers learn to mentally reconstruct the three dimensional (3D) relationships of the coronary arterial branches. Graphic computer technology can assist angiographers to more quickly visualize the coronary 3D structure from limited initial views and then help to determine additional helpful views by predicting subsequent angiograms before they are obtained. A new computer method for facilitating 3D reconstruction and visualization of human coronary arteries was evaluated by reconstructing biplane left coronary angiograms from 30 patients. The accuracy of the reconstruction was assessed in two ways: 1) by comparing the vessel's centerlines of the actual angiograms with the centerlines of a 2D projection of the 3D model projected into the exact angle of the actual angiogram; and 2) by comparing two 3D models generated by different simultaneous pairs on angiograms. The inter- and intraobserver variability of reconstruction were evaluated by mathematically comparing the 3D model centerlines of repeated reconstructions. The average absolute corrected displacement of 14,662 vessel centerline points in 2D from 30 patients was 1.64 +/- 2.26 mm. The average corrected absolute displacement of 3D models generated from different biplane pairs was 7.08 +/- 3.21 mm. The intraobserver variability of absolute 3D corrected displacement was 5.22 +/- 3.39 mm. The interobserver variability was 6.6 +/- 3.1 mm. The centerline analyses show that the reconstruction algorithm is mathematically accurate and reproducible. The figures presented in this report put these measurement errors into clinical perspective showing that they yield an accurate representation of the clinically relevant information seen on the actual angiograms. These data show that this technique can be clinically useful by accurately displaying in three dimensions the complex relationships of the branches of the coronary arterial tree.
Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures.
Högel, F; Gerlach, U V; Südkamp, N P; Müller, C A
2010-12-01
To determine whether reamed or unreamed intramedullary nailing of femoral fractures results in higher incidence of pulmonary fat embolism, three different methods of intramedullary nailing were compared in sheep. To analyze the presence of bone marrow fat embolism in pulmonary arteries, histological evaluation was undertaken using a quantitative computer-assisted measurement system. In this experimental model of 27 female Swiss alpine sheep, an osteotomy of the proximal femur was conducted in each animal. Then, the animals were divided into three groups according to the method of treatment: two different reamed intramedullary nailing techniques and an unreamed nailing technique were used. In the first group "ER" (experimental reamer; n=9), the nail was inserted after reaming with an experimental reamer; in the second group "CR" (conventional reamer; n=7), the intramedullary nail was inserted after reaming with the conventional AO-reamer. In the third group "UN" (unreamed; n=8) unreamed nailing was performed. During the operation procedure intramedullary pressure was measured in the distal fragment. After sacrificing the animals, quantitative histological analyses of bone marrow fat embolism in pulmonary arteries were done using osmium tetroxide fixation and staining of the fat. The measurement of intramedullary pressure showed significantly lower values for reamed nailing than for the unreamed technique. The quantitative histological evaluation of lung vessels concerning bone marrow fat embolism revealed a statistically significant difference between reamed and unreamed insertion of the nail: 7.77%±6.93 (ER) and 6.66%±5.61 (CR) vs. 16.25%±10.05 (UN) (p<0.05) of the assessed lung vessels were filled with fat emboli. However, no difference was found between the traditional and experimental reamer. Intramedullary nailing after reaming is a safe procedure with low systemic embolisation when compared to the unreamed insertion of the nail. Copyright © 2010 Elsevier Ltd. All rights reserved.
Li, Xiaohui; Yu, Jianhua; Gong, Yuekun; Ren, Kaijing; Liu, Jun
2015-04-21
To assess the early postoperative clinical and radiographic outcomes after navigation-assisted or standard instrumentation total knee arthroplasty (TKA). From August 2007 to May 2008, 60 KSS-A type patients underwent 67 primary TKA operations by the same surgical team. Twenty-two operations were performed with the Image-free navigation system with an average age of 64.5 years while the remaining 45 underwent conventional manual procedures with an average age of 66 years. Their preoperative demographic and functional data had no statistical differences (P>0.05). The operative duration, blood loss volume and hospitalization days were compared for two groups. And radiographic data included coronal femoral component angle, coronal tibial component angle, sagittal femoral component angle, sagittal tibial component angle and coronal tibiofemoral angle after one month. And functional assessment scores were evaluated at 1, 3 and 6 months postoperatively. Operative duration was significantly longer for computer navigation (P<0.05). The average blood loss volume was 555.26 ml in computer navigation group and 647.56 ml in conventional manual method group (P<0.05). And hospitalization stay was shorter in computer navigation group than that in conventional method group (7.74 vs 8.68 days) (P=0.04). The alignment deviation was better in computer-assisted group than that in conventional manual method group (P<0.05). The percentage of patients with a coronal tibiofemoral angle within ±3 of ideal value was 95.45% for computer-assisted mini-invasive TKA group and 80% for conventional TKA group (P=0.003). The Knee Society Clinical Rating Score was higher in computer-assisted group than that in conventional manual method group at 1 and 3 montha post-operation. However, no statistical inter-group difference existed at 6 months post-operation. Navigation allows a surgeon to precisely implant the components for TKA. And it offers faster functional recovery and shorter hospitalization stay. At 6 months post-operation, there is no statistical inter-group difference in KSS scores.
Cheng, Tao; Zhang, Guoyou; Zhang, Xianlong
2011-12-01
The aim of computer-assisted surgery is to improve accuracy and limit the range of surgical variability. However, a worldwide debate exists regarding the importance and usefulness of computer-assisted navigation for total knee arthroplasty (TKA). The main purpose of this study is to summarize and compare the radiographic outcomes of TKA performed using imageless computer-assisted navigation compared with conventional techniques. An electronic search of PubMed, EMBASE, Web of Science, and Cochrane library databases was made, in addition to manual search of major orthopedic journals. A meta-analysis of 29 quasi-randomized/randomized controlled trials (quasi-RCTs/RCTs) and 11 prospective comparative studies was conducted through a random effects model. Additional a priori sources of clinical heterogeneity were evaluated by subgroup analysis with regard to radiographic methods. When the outlier cut-off value of lower limb axis was defined as ±2° or ±3° from the neutral, the postoperative full-length radiographs demonstrated that the risk ratio was 0.54 or 0.39, respectively, which were in favor of the navigated group. When the cut-off value used for the alignment in the coronal and sagittal plane was 2° or 3°, imageless navigation significantly reduced the outlier rate of the femoral and tibial components compared with the conventional group. Notably, computed tomography scans demonstrated no statistically significant differences between the two groups regarding the outliers in the rotational alignment of the femoral and tibial components; however, there was strong statistical heterogeneity. Our results indicated that imageless computer-assisted navigation systems improve lower limb axis and component orientation in the coronal and sagittal planes, but not the rotational alignment in TKA. Further multiple-center clinical trials with long-term follow-up are needed to determine differences in the clinical and functional outcomes of knee arthroplasties performed using computer-assisted techniques. Copyright © 2011 Elsevier Inc. All rights reserved.
Mapping Quantitative Traits in Unselected Families: Algorithms and Examples
Dupuis, Josée; Shi, Jianxin; Manning, Alisa K.; Benjamin, Emelia J.; Meigs, James B.; Cupples, L. Adrienne; Siegmund, David
2009-01-01
Linkage analysis has been widely used to identify from family data genetic variants influencing quantitative traits. Common approaches have both strengths and limitations. Likelihood ratio tests typically computed in variance component analysis can accommodate large families but are highly sensitive to departure from normality assumptions. Regression-based approaches are more robust but their use has primarily been restricted to nuclear families. In this paper, we develop methods for mapping quantitative traits in moderately large pedigrees. Our methods are based on the score statistic which in contrast to the likelihood ratio statistic, can use nonparametric estimators of variability to achieve robustness of the false positive rate against departures from the hypothesized phenotypic model. Because the score statistic is easier to calculate than the likelihood ratio statistic, our basic mapping methods utilize relatively simple computer code that performs statistical analysis on output from any program that computes estimates of identity-by-descent. This simplicity also permits development and evaluation of methods to deal with multivariate and ordinal phenotypes, and with gene-gene and gene-environment interaction. We demonstrate our methods on simulated data and on fasting insulin, a quantitative trait measured in the Framingham Heart Study. PMID:19278016
García de Diego, Laura; Cuervo, Marta; Martínez, J. Alfredo
2015-01-01
Computer assisted instruction (CAI) is an effective tool for evaluating and training students and professionals. In this article we will present a learning-oriented CAI, which has been developed for students and health professionals to acquire and retain new knowledge through the practice. A two-phase pilot evaluation was conducted, involving 8 nutrition experts and 30 postgraduate students, respectively. In each training session, the software developed guides users in the integral evaluation of a patient’s nutritional status and helps them to implement actions. The program includes into the format clinical tools, which can be used to recognize possible patient’s needs, to improve the clinical reasoning and to develop professional skills. Among them are assessment questionnaires and evaluation criteria, cardiovascular risk charts, clinical guidelines and photographs of various diseases. This CAI is a complete software package easy to use and versatile, aimed at clinical specialists, medical staff, scientists, educators and clinical students, which can be used as a learning tool. This application constitutes an advanced method for students and health professionals to accomplish nutritional assessments combining theoretical and empirical issues, which can be implemented in their academic curriculum. PMID:25978456
García de Diego, Laura; Cuervo, Marta; Martínez, J Alfredo
2015-01-01
Computer assisted instruction (CAI) is an effective tool for evaluating and training students and professionals. In this article we will present a learning-oriented CAI, which has been developed for students and health professionals to acquire and retain new knowledge through the practice. A two-phase pilot evaluation was conducted, involving 8 nutrition experts and 30 postgraduate students, respectively. In each training session, the software developed guides users in the integral evaluation of a patient's nutritional status and helps them to implement actions. The program includes into the format clinical tools, which can be used to recognize possible patient's needs, to improve the clinical reasoning and to develop professional skills. Among them are assessment questionnaires and evaluation criteria, cardiovascular risk charts, clinical guidelines and photographs of various diseases. This CAI is a complete software package easy to use and versatile, aimed at clinical specialists, medical staff, scientists, educators and clinical students, which can be used as a learning tool. This application constitutes an advanced method for students and health professionals to accomplish nutritional assessments combining theoretical and empirical issues, which can be implemented in their academic curriculum.
NASA Technical Reports Server (NTRS)
Jones, H. W.
1984-01-01
The computer-assisted C-matrix, Loewdin-alpha-function, single-center expansion method in spherical harmonics has been applied to the three-center nuclear-attraction integral (potential due to the product of separated Slater-type orbitals). Exact formulas are produced for 13 terms of an infinite series that permits evaluation to ten decimal digits of an example using 1s orbitals.
Zhang, Jiafeng; Zhang, Pei; Fraser, Katharine H.; Griffith, Bartley P.; Wu, Zhongjun J.
2012-01-01
With the recent advances in computer technology, computational fluid dynamics (CFD) has become an important tool to design and improve blood contacting artificial organs, and to study the device-induced blood damage. Commercial CFD software packages are readily available, and multiple CFD models are provided by CFD software developers. However, the best approach of using CFD effectively to characterize fluid flow and to predict blood damage in these medical devices remains debatable. This study aimed to compare these CFD models and provide useful information on the accuracy of each model in modeling blood flow in circulatory assist devices. The laminar and five turbulence models (Spalart-Allmaras, k-ε (k-epsilon), k-ω (k-omega), SST (Menter’s Shear Stress Transport), and Reynolds Stress) were implemented to predict blood flow in a clinically used circulatory assist device, CentriMag® centrifugal blood pump (Thoratec, MA). In parallel, a transparent replica of the CentriMag® pump was constructed and selected views of the flow fields were measured with digital particle image velocimetry (DPIV). CFD results were compared with the DPIV experimental results. Compared with the experiment, all the selected CFD models predicted the flow pattern fairly well except the area of the outlet. However, quantitatively, the laminar model results were the most deviated from the experimental data. On the other hand, k-ε RNG models and Reynolds Stress model are the most accurate. In conclusion, for the circulatory assist devices, turbulence models provide more accurate results than laminar model. Among the selected turbulence models, k-ε and Reynolds Stress Method models are recommended. PMID:23441681
Desiderata for a Computer-Assisted Audit Tool for Clinical Data Source Verification Audits
Duda, Stephany N.; Wehbe, Firas H.; Gadd, Cynthia S.
2013-01-01
Clinical data auditing often requires validating the contents of clinical research databases against source documents available in health care settings. Currently available data audit software, however, does not provide features necessary to compare the contents of such databases to source data in paper medical records. This work enumerates the primary weaknesses of using paper forms for clinical data audits and identifies the shortcomings of existing data audit software, as informed by the experiences of an audit team evaluating data quality for an international research consortium. The authors propose a set of attributes to guide the development of a computer-assisted clinical data audit tool to simplify and standardize the audit process. PMID:20841814
Matrix evaluation of science objectives
NASA Technical Reports Server (NTRS)
Wessen, Randii R.
1994-01-01
The most fundamental objective of all robotic planetary spacecraft is to return science data. To accomplish this, a spacecraft is fabricated and built, software is planned and coded, and a ground system is designed and implemented. However, the quantitative analysis required to determine how the collection of science data drives ground system capabilities has received very little attention. This paper defines a process by which science objectives can be quantitatively evaluated. By applying it to the Cassini Mission to Saturn, this paper further illustrates the power of this technique. The results show which science objectives drive specific ground system capabilities. In addition, this process can assist system engineers and scientists in the selection of the science payload during pre-project mission planning; ground system designers during ground system development and implementation; and operations personnel during mission operations.
Designing and Creating Computer-Assisted Instruction.
ERIC Educational Resources Information Center
McMeen, George R.
Designed to encourage the use of a defined methodology and careful planning in creating computer-assisted instructional programs, this paper describes the instructional design process, compares computer-assisted instruction (CAI) and programmed instruction (PI), and discusses pragmatic concerns in computer programming. Topics addressed include:…
Macke, Jeremy J; Woo, Raymund; Varich, Laura
2016-06-01
This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.
CD-ROMs review 1995-1997: a multicentre pilot trial.
Grey-Lloyd, J
1998-03-01
This article describes an evaluation of CD-ROMs carried out at four NHS Trust Libraries in Wales. It covers interactive CD-ROMs which take the form of either computer assisted learning programs, encyclopaedia or well-known text books.
Quantitative evaluation of the voice range profile in patients with voice disorder.
Ikeda, Y; Masuda, T; Manako, H; Yamashita, H; Yamamoto, T; Komiyama, S
1999-01-01
In 1953, Calvet first displayed the fundamental frequency (pitch) and sound pressure level (intensity) of a voice on a two-dimensional plane and created a voice range profile. This profile has been used to evaluate clinically various vocal disorders, although such evaluations to date have been subjective without quantitative assessment. In the present study, a quantitative system was developed to evaluate the voice range profile utilizing a personal computer. The area of the voice range profile was defined as the voice volume. This volume was analyzed in 137 males and 175 females who were treated for various dysphonias at Kyushu University between 1984 and 1990. Ten normal subjects served as controls. The voice volume in cases with voice disorders significantly decreased irrespective of the disease and sex. Furthermore, cases having better improvement after treatment showed a tendency for the voice volume to increase. These findings illustrated the voice volume as a useful clinical test for evaluating voice control in cases with vocal disorders.
Denny, Margaret; Higgins, Agnes
2003-06-01
Despite the available literature that identifies the value of integrating computer-assisted learning into the curriculum, psychiatric nurse education lags behind in this area of curriculum development. The purpose of this paper is to report on a pilot project involving the use of a computer assisted learning (CAL) interactive multimedia (IMM) package called 'Admissions,' as a self-directed learning tool with two-second year psychiatric nursing students. The students were on a practice placement in an Irish mental health service. The aim of using the multimedia resource was to augment the students' learning during their practice placement and enable them to re-examine the issue of psychosis from a multiplicity of perspectives. This paper provides a brief description of the interactive multimedia package, together with a discussion on the support offered to the students during its use. experiential taxonomy is used as a framework to guide the discussion on the learning and evaluation process used. Feedback from the students suggests that the CAL package is easy to use, informative and promoted independence and self-directed study.
Blocher, Jacquelyn B; Fujikawa, Mayu; Sung, Connie; Jackson, Daren C; Jones, Jana E
2013-04-01
Anxiety disorders are prevalent in children with epilepsy. The purpose of this study was to evaluate the efficacy, adaptability, and feasibility of a manual-based, computer-assisted cognitive behavioral therapy (CBT) intervention for anxiety disorders in children with epilepsy. Fifteen anxious youth (aged 8-13 years) with epilepsy completed 12 weeks of manualized computer-assisted CBT. The children and parents completed a semi-structured interview at baseline, and questionnaires assessing symptoms of anxiety, depression, and behavior problems were completed prior to treatment, at treatment midpoint, after treatment completion, and at three months posttreatment. There were significant reductions in the symptoms of anxiety and depression reported by the children at completion of the intervention and at the three-month follow-up. Similarly, the parents reported fewer symptoms of anxiety and a reduction in behavior problems. No adverse events were reported. This CBT intervention for children with epilepsy and anxiety disorders appears to be safe, effective, and feasible and should be incorporated into future intervention studies. Copyright © 2012 Elsevier Inc. All rights reserved.
León, Ileana R.; Schwämmle, Veit; Jensen, Ole N.; Sprenger, Richard R.
2013-01-01
The majority of mass spectrometry-based protein quantification studies uses peptide-centric analytical methods and thus strongly relies on efficient and unbiased protein digestion protocols for sample preparation. We present a novel objective approach to assess protein digestion efficiency using a combination of qualitative and quantitative liquid chromatography-tandem MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein fractions. We evaluated nine trypsin-based digestion protocols, based on standard in-solution or on spin filter-aided digestion, including new optimized protocols. We investigated various reagents for protein solubilization and denaturation (dodecyl sulfate, deoxycholate, urea), several trypsin digestion conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents before analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative liquid chromatography-tandem MS workflow quantified over 3700 distinct peptides with 96% completeness between all protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows for efficient, unbiased generation and recovery of peptides from all protein classes, including membrane proteins. This deoxycholate-assisted protocol was also optimal for spin filter-aided digestions as compared with existing methods. PMID:23792921
Gross, Colin A; Reddy, Chandan K; Dazzo, Frank B
2010-02-01
Quantitative microscopy and digital image analysis are underutilized in microbial ecology largely because of the laborious task to segment foreground object pixels from background, especially in complex color micrographs of environmental samples. In this paper, we describe an improved computing technology developed to alleviate this limitation. The system's uniqueness is its ability to edit digital images accurately when presented with the difficult yet commonplace challenge of removing background pixels whose three-dimensional color space overlaps the range that defines foreground objects. Image segmentation is accomplished by utilizing algorithms that address color and spatial relationships of user-selected foreground object pixels. Performance of the color segmentation algorithm evaluated on 26 complex micrographs at single pixel resolution had an overall pixel classification accuracy of 99+%. Several applications illustrate how this improved computing technology can successfully resolve numerous challenges of complex color segmentation in order to produce images from which quantitative information can be accurately extracted, thereby gain new perspectives on the in situ ecology of microorganisms. Examples include improvements in the quantitative analysis of (1) microbial abundance and phylotype diversity of single cells classified by their discriminating color within heterogeneous communities, (2) cell viability, (3) spatial relationships and intensity of bacterial gene expression involved in cellular communication between individual cells within rhizoplane biofilms, and (4) biofilm ecophysiology based on ribotype-differentiated radioactive substrate utilization. The stand-alone executable file plus user manual and tutorial images for this color segmentation computing application are freely available at http://cme.msu.edu/cmeias/ . This improved computing technology opens new opportunities of imaging applications where discriminating colors really matter most, thereby strengthening quantitative microscopy-based approaches to advance microbial ecology in situ at individual single-cell resolution.
Doblas, Ana; Sánchez-Ortiga, Emilio; Martínez-Corral, Manuel; Saavedra, Genaro; Garcia-Sucerquia, Jorge
2014-04-01
The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the microscope allows single-shot QPI in DHM by using telecentric imaging systems. Quantitative phase maps of a section of the head of the drosophila melanogaster fly and of red blood cells are obtained via single-shot DHM with no numerical postprocessing. With these maps we show that the use of telecentric DHM provides larger field of view for a given magnification and permits more accurate QPI measurements with less number of computational operations.
3D Slicer as an Image Computing Platform for the Quantitative Imaging Network
Fedorov, Andriy; Beichel, Reinhard; Kalpathy-Cramer, Jayashree; Finet, Julien; Fillion-Robin, Jean-Christophe; Pujol, Sonia; Bauer, Christian; Jennings, Dominique; Fennessy, Fiona; Sonka, Milan; Buatti, John; Aylward, Stephen; Miller, James V.; Pieper, Steve; Kikinis, Ron
2012-01-01
Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the context of personalized therapy and evaluation of treatment response. Computerized analysis is an important component contributing to reproducibility and efficiency of the quantitative imaging techniques. The success of quantitative imaging is contingent on robust analysis methods and software tools to bring these methods from bench to bedside. 3D Slicer is a free open source software application for medical image computing. As a clinical research tool, 3D Slicer is similar to a radiology workstation that supports versatile visualizations but also provides advanced functionality such as automated segmentation and registration for a variety of application domains. Unlike a typical radiology workstation, 3D Slicer is free and is not tied to specific hardware. As a programming platform, 3D Slicer facilitates translation and evaluation of the new quantitative methods by allowing the biomedical researcher to focus on the implementation of the algorithm, and providing abstractions for the common tasks of data communication, visualization and user interface development. Compared to other tools that provide aspects of this functionality, 3D Slicer is fully open source and can be readily extended and redistributed. In addition, 3D Slicer is designed to facilitate the development of new functionality in the form of 3D Slicer extensions. In this paper, we present an overview of 3D Slicer as a platform for prototyping, development and evaluation of image analysis tools for clinical research applications. To illustrate the utility of the platform in the scope of QIN, we discuss several use cases of 3D Slicer by the existing QIN teams, and we elaborate on the future directions that can further facilitate development and validation of imaging biomarkers using 3D Slicer. PMID:22770690
Evaluating Integrated Task Based Activities and Computer Assisted Language Learning (CALL)
ERIC Educational Resources Information Center
Anwar, Khoirul; Husniah, Rohmy
2016-01-01
This study is to evaluate the implementation of Task Activities based on CALL which consist of observing, questioning, exploring, and communicating. The developed materials are nine chapters that had been implemented in two different classes of SMPN 1 Gresik and SMPM 4 Gresik in Indonesia. Of quesionnaires and interviews, the results indicate that…
ERIC Educational Resources Information Center
Vollands, Stacy R.; And Others
A study evaluated the effect software for self-assessment and management of reading practice had on reading achievement and motivation in two primary schools in Aberdeen, Scotland. The program utilized was The Accelerated Reader (AR) which was designed to enable curriculum based assessment of reading comprehension within the classroom. Students…
ERIC Educational Resources Information Center
Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo
2008-01-01
This usability study evaluated users' perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption.…
Intelligent Computer-Assisted Language Learning.
ERIC Educational Resources Information Center
Harrington, Michael
1996-01-01
Introduces the field of intelligent computer assisted language learning (ICALL) and relates them to current practice in computer assisted language learning (CALL) and second language learning. Points out that ICALL applies expertise from artificial intelligence and the computer and cognitive sciences to the development of language learning…
Ye, Hongping; Hill, John; Kauffman, John; Han, Xianlin
2010-05-01
The capability of iTRAQ (isotope tags for relative and absolute quantification) reagents coupled with matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) as a qualitative and quantitative technique for the analysis of complicated protein pharmaceutical mixtures was evaluated. Mixtures of Somavert and Miacalcin with a small amount of bovine serum albumin (BSA) as an impurity were analyzed. Both Somavert and Miacalcin were qualitatively identified, and BSA was detected at levels as low as 0.8mol%. Genotropin and Somavert were compared in a single experiment, and all of the distinct amino acid residues from the two proteins were readily identified. Four somatropin drug products (Genotropin, Norditropin, Jintropin, and Omnitrope) were compared using the iTRAQ/MALDI-MS method to determine the similarity between their primary structures and quantify the amount of protein in each product. All four product samples were well labeled and successfully compared when a filtration cleanup step preceded iTRAQ labeling. The quantitative accuracy of the iTRAQ method was evaluated. In all cases, the accuracy of experimentally determined protein ratios was higher than 90%, and the relative standard deviation (RSD) was less than 10%. The iTRAQ and global internal standard technology (GIST) methods were compared, and the iTRAQ method provided both higher sequence coverage and enhanced signal intensity. Published by Elsevier Inc.
Folan, Alyce; Barclay, Linda; Cooper, Cathy; Robinson, Merren
2015-01-01
Assistive technology for computer access can be used to facilitate people with a spinal cord injury to utilize mainstream computer applications, thereby enabling participation in a variety of meaningful occupations. The aim of this study was to gain an understanding of the experiences of clients with tetraplegia trialing assistive technologies for computer access during different stages in a public rehabilitation service. In order to explore the experiences of clients with tetraplegia trialing assistive technologies for computer use, qualitative methodology was selected. Data were collected from seven participants using semi-structured interviews, which were audio-taped, transcribed and analyzed thematically. Three main themes were identified. These were: getting back into life, assisting in adjusting to injury and learning new skills. The findings from this study demonstrated that people with tetraplegia can be assisted to return to previous life roles or engage in new roles, through developing skills in the use of assistive technology for computer access. Being able to use computers for meaningful activities contributed to the participants gaining an enhanced sense of self-efficacy, and thereby quality of life. Implications for Rehabilitation Findings from this pilot study indicate that people with tetraplegia can be assisted to return to previous life roles, and develop new roles that have meaning to them through the use of assistive technologies for computer use. Being able to use the internet to socialize, and complete daily tasks, contributed to the participants gaining a sense of control over their lives. Early introduction to assistive technology is important to ensure sufficient time for newly injured people to feel comfortable enough with the assistive technology to use the computers productively by the time of discharge. Further research into this important and expanding area is indicated.
Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon
2016-03-01
The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, p<0.001). The five- and 10-year survival rates were 97.1% and 89.6%, respectively. No difference was detected in nine-year survival rates (p=0.369) between the two groups, although the clinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.
Raineri, M; Traina, M; Rotolo, A; Candela, B; Lombardo, R M; Raineri, A A
1993-05-01
Thallium-201 scintigraphy is a widely used noninvasive procedure for the detection and prognostic assessment of patients with suspected or proven coronary artery disease. Thallium uptake can be evaluated by a visual analysis or by a quantitative interpretation. Quantitative scintigraphy enhances disease detection in individual coronary arteries, provides a more precise estimate of the amount of ischemic myocardium, distinguishing scar from hypoperfused tissue. Due to the great deal of data, analysis, interpretation and comparison of thallium uptake can be very complex. We designed a computer-based system for the interpretation of quantitative thallium-201 scintigraphy data uptake. We used a database (DataEase 4.2-DataEase Italia). Our software has the following functions: data storage; calculation; conversion of numerical data into different definitions classifying myocardial perfusion; uptake data comparison; automatic conclusion; comparison of different scintigrams for the same patient. Our software is made up by 4 sections: numeric analysis, descriptive analysis, automatic conclusion, clinical remarks. We introduced in the computer system appropriate information, "logical paths", that use the "IF ... THEN" rules. The software executes these rules in order to analyze the myocardial regions in the 3 phases of scintigraphic analysis (stress, redistribution, re-injection), in the 3 projections (LAO 45 degrees, LAT,ANT), considering our uptake cutoff, obtaining, finally, the automatic conclusions. For these reasons, our computer-based system could be considered a real "expert system".
Nakagawa, Hiroaki; Nagatani, Yukihiro; Takahashi, Masashi; Ogawa, Emiko; Tho, Nguyen Van; Ryujin, Yasushi; Nagao, Taishi; Nakano, Yasutaka
2016-01-01
The 2011 official statement of idiopathic pulmonary fibrosis (IPF) mentions that the extent of honeycombing and the worsening of fibrosis on high-resolution computed tomography (HRCT) in IPF are associated with the increased risk of mortality. However, there are few reports about the quantitative computed tomography (CT) analysis of honeycombing area. In this study, we first proposed a computer-aided method for quantitative CT analysis of honeycombing area in patients with IPF. We then evaluated the correlations between honeycombing area measured by the proposed method with that estimated by radiologists or with parameters of PFTs. Chest HRCTs and pulmonary function tests (PFTs) of 36 IPF patients, who were diagnosed using HRCT alone, were retrospectively evaluated. Two thoracic radiologists independently estimated the honeycombing area as Identified Area (IA) and the percentage of honeycombing area to total lung area as Percent Area (PA) on 3 axial CT slices for each patient. We also developed a computer-aided method to measure the honeycombing area on CT images of those patients. The total honeycombing area as CT honeycombing area (HA) and the percentage of honeycombing area to total lung area as CT %honeycombing area (%HA) were derived from the computer-aided method for each patient. HA derived from three CT slices was significantly correlated with IA (ρ=0.65 for Radiologist 1 and ρ=0.68 for Radiologist 2). %HA derived from three CT slices was also significantly correlated with PA (ρ=0.68 for Radiologist 1 and ρ=0.70 for Radiologist 2). HA and %HA derived from all CT slices were significantly correlated with FVC (%pred.), DLCO (%pred.), and the composite physiologic index (CPI) (HA: ρ=-0.43, ρ=-0.56, ρ=0.63 and %HA: ρ=-0.60, ρ=-0.49, ρ=0.69, respectively). The honeycombing area measured by the proposed computer-aided method was correlated with that estimated by expert radiologists and with parameters of PFTs. This quantitative CT analysis of honeycombing area may be useful and reliable in patients with IPF. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tezuka, Miwa; Kanno, Kazutaka; Bunsen, Masatoshi
2016-08-01
Reservoir computing is a machine-learning paradigm based on information processing in the human brain. We numerically demonstrate reservoir computing with a slowly modulated mask signal for preprocessing by using a mutually coupled optoelectronic system. The performance of our system is quantitatively evaluated by a chaotic time series prediction task. Our system can produce comparable performance with reservoir computing with a single feedback system and a fast modulated mask signal. We showed that it is possible to slow down the modulation speed of the mask signal by using the mutually coupled system in reservoir computing.
Electronic Learning in Yugoslavia.
ERIC Educational Resources Information Center
Barker, Philip G.
1990-01-01
Describes a course taught at the University of Zagreb (Yugoslavia) on electronic learning methods based upon computer-assisted learning techniques. The course content is outlined, including lectures, workshops, videotapes, demonstration software, and courseware authoring; a multimedia teaching laboratory is described; and an evaluation of course…
Teaching a Model-based Climatology Using Energy Balance Simulation.
ERIC Educational Resources Information Center
Unwin, David
1981-01-01
After outlining the difficulties of teaching climatology within an undergraduate geography curriculum, the author describes and evaluates the use of a computer assisted simulation to model surface energy balance and the effects of land use changes on local climate. (AM)
1996-11-01
being evaluated in cadaver trials. Shumeet Baluja was supported by a National Science Foundation Graduate Student Fellowship and a Graduate Student...partially supported by a National Science Foundation National Challenge grant (award IRI-9422734).
Computer Assisted Learning in Numeracy.
ERIC Educational Resources Information Center
Hollin, Freda
Computer-assisted learning in numeracy for adults is far less developed than computer-assisted learning in literacy. Although a great many software programs exist, few are suitable for adults and many offer only drill and practice exercises instead of teaching genuine computer skills. One approach instructors can take is to have their students use…
Application of computer assisted moire to the study of a crack tip
NASA Astrophysics Data System (ADS)
Sciammarella, C. A.; Albertazzi, A., Jr.; Mourikes, J.
The basic principles of computer assisted moire are discussed. The influence of the image sensor and its finite dimensions on the sampling theorem requirements is discussed. Criteria for the selection of grating pitch on the basis of the spatial bandwidth of the pattern to be observed and the requirements arising from sensitivity considerations are given. The method is used to analyze the strain field in the neighborhood of the crack tip of a standard ASTM compact tension specimen. From the displacements the strains are computed, and from the strains the stresses are obtained using the generalized Ramberg-Osgood stress strain relationship. The stresses are used to compute the values for the J-integral in several circuits surrounding the crack. Good agreement is obtained between the values of the stress intensity factors obtained by different methods. The plastic region surrounding the crack does not show a HRR field and thus the usual rationale to justify the J-integral methods must be re-evaluated.
1980-06-01
I.indslev was peerless in leadership and management support of this project. The in anscriPt benefited from the reviews of several individuals. and...i4 7 Medical L.aboratorv achievement as a function of learner strategy preference for processing information and CAI vs. lecture...characteristics ’were used to assist CAI authors in the initial development of instructional materials and strategies appropriate to the target population in each
''Are Chemistry Educational Apps Useful?''--A Quantitative Study with Three In-House Apps
ERIC Educational Resources Information Center
Ping, Grace Lee Yuan; Lok, Chang; Yeat, Tan Wei; Cherynn, Tan Jie Ying; Tan, Emelyn Sue Qing
2018-01-01
Three internally developed mobile apps, "3D Sym Op", "SM2 Chem" and "ARMolVis," available for free on both the Apple App Store and Google Play Store were evaluated in seven studies. Each study was a systematic process of Pre-Test, In-lecture App Demo, App Assisted Interactive Tutorials (AAITs) and/or Independent App…
de Boer, Anne H; Hagedoorn, Paul; Woolhouse, Robert; Wynn, Ed
2012-09-01
To use computational fluid dynamics (CFD) for evaluating and understanding the performance of the high-dose disposable Twincer™ dry powder inhaler, as well as to learn the effect of design modifications on dose entrainment, powder dispersion and retention behaviour. Comparison of predicted flow and particle behaviour from CFD computations with experimental data obtained with cascade impactor and laser diffraction analysis. Inhaler resistance, flow split, particle trajectories and particle residence times can well be predicted with CFD for a multiple classifier based inhaler like the Twincer™. CFD computations showed that the flow split of the Twincer™ is independent of the pressure drop across the inhaler and that the total flow rate can be decreased without affecting the dispersion efficacy or retention behaviour. They also showed that classifier symmetry can be improved by reducing the resistance of one of the classifier bypass channels, which for the current concept does not contribute to the swirl in the classifier chamber. CFD is a highly valuable tool for development and optimisation of dry powder inhalers. CFD can assist adapting the inhaler design to specific physico-chemical properties of the drug formulation with respect to dispersion and retention behaviour. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.