Economics of infection control surveillance technology: cost-effective or just cost?
Furuno, Jon P; Schweizer, Marin L; McGregor, Jessina C; Perencevich, Eli N
2008-04-01
Previous studies have suggested that informatics tools, such as automated alert and decision support systems, may increase the efficiency and quality of infection control surveillance. However, little is known about the cost-effectiveness of these tools. We focus on 2 types of economic analyses that have utility in assessing infection control interventions (cost-effectiveness analysis and business-case analysis) and review the available literature on the economics of computerized infection control surveillance systems. Previous studies on the effectiveness of computerized infection control surveillance have been limited to assessments of whether these tools increase the sensitivity and specificity of surveillance over traditional methods. Furthermore, we identified only 2 studies that assessed the costs associated with computerized infection control surveillance. Thus, it remains unknown whether computerized infection control surveillance systems are cost-effective and whether use of these systems improves patient outcomes. The existing data are insufficient to allow for a summary conclusion on the cost-effectiveness of infection control surveillance technology. All future studies of computerized infection control surveillance systems should aim to collect outcomes and economic data to inform decision making and assist hospitals with completing business-cases analyses.
Computerized Numerical Control Curriculum Guide.
ERIC Educational Resources Information Center
Reneau, Fred; And Others
This guide is intended for use in a course in programming and operating a computerized numerical control system. Addressed in the course are various aspects of programming and planning, setting up, and operating machines with computerized numerical control, including selecting manual or computer-assigned programs and matching them with…
1984-06-20
AD-A162 ±88 FEASIBILITY STUDY FOR A COMPUTERIZED SERIALS CONTROL 1/1 SYSTEM IN THE DEFENS (U) DEFENSE COMMUNICATIONS AGENCY WASHINGTON DC TECHNICAL...NATIONAL BUREAU OF STANDARDS- 1963-A 0FEASIBILITY STUDY FOR A COMPUTERIZED SERIALS CONTROL SYSTEM IN THE DEFENSE COMMUNICATIONS 0AGENCY TECHNICAL AND...ABSTRACT 21. ABSTRACT SECURITY CLASSIFICATION UNCLASSIFIED/UNLIMITED R1 SAME AS RPT. 0 DTIC USERS 0 UNCLASSIFIED 22&. NAME OF RESPONSIBLE INDIVIDUAL 22b
2009-01-01
Current care guidelines recommend glucose control (GC) in critically ill patients. To achieve GC, many ICUs have implemented a (nurse-based) protocol on paper. However, such protocols are often complex, time-consuming, and can cause iatrogenic hypoglycemia. Computerized glucose regulation protocols may improve patient safety, efficiency, and nurse compliance. Such computerized clinical decision support systems (Cuss) use more complex logic to provide an insulin infusion rate based on previous blood glucose levels and other parameters. A computerized CDSS for glucose control has the potential to reduce overall workload, reduce the chance of human cognitive failure, and improve glucose control. Several computer-assisted glucose regulation programs have been published recently. In order of increasing complexity, the three main types of algorithms used are computerized flowcharts, Proportional-Integral-Derivative (PID), and Model Predictive Control (MPC). PID is essentially a closed-loop feedback system, whereas MPC models the behavior of glucose and insulin in ICU patients. Although the best approach has not yet been determined, it should be noted that PID controllers are generally thought to be more robust than MPC systems. The computerized Cuss that are most likely to emerge are those that are fully a part of the routine workflow, use patient-specific characteristics and apply variable sampling intervals. PMID:19849827
Computerized adaptive control weld skate with CCTV weld guidance project
NASA Technical Reports Server (NTRS)
Wall, W. A.
1976-01-01
This report summarizes progress of the automatic computerized weld skate development portion of the Computerized Weld Skate with Closed Circuit Television (CCTV) Arc Guidance Project. The main goal of the project is to develop an automatic welding skate demonstration model equipped with CCTV weld guidance. The three main goals of the overall project are to: (1) develop a demonstration model computerized weld skate system, (2) develop a demonstration model automatic CCTV guidance system, and (3) integrate the two systems into a demonstration model of computerized weld skate with CCTV weld guidance for welding contoured parts.
NASA Technical Reports Server (NTRS)
Horton, W.; Kinsey, M.
1967-01-01
Computerized parts list system compiles and summarize all pertinent and available information on complex new systems. The parts list system consists of three computer subroutines - list of parts, parts numerical sequence list, and specifications list.
A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.
Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio
2014-08-01
To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
ERIC Educational Resources Information Center
Combs, Joseph, Jr.
1995-01-01
Reviews the Total Library Computerization program, which can be used to manage small to midsized libraries. Discusses costs; operating system requirements; security features; user-interface styles; and system modules including online cataloging, circulation, serials control, acquisitions, authorities control, and interlibrary loan. (Author/JMV)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, J M; Ehinger, M H; Joseph, C
1978-10-01
Development work on a computerized system for nuclear materials control and accounting in a nuclear fuel reprocessing plant is described and evaluated. Hardware and software were installed and tested to demonstrate key measurement, measurement control, and accounting requirements at accountability input/output points using natural uranium. The demonstration included a remote data acquisition system which interfaces process and special instrumentation to a cenral processing unit.
Computerization of material test data reporting system : interim report.
DOT National Transportation Integrated Search
1973-09-01
This study was initiated to provide an integrated system of reporting, storing, and retrieving of construction and material test data using computerized (storage-retrieval) and quality control techniques. The findings reported in this interim report ...
Informap... a computerized information system for fire planning and fire control
Theodore G. Storey; Ross D. Carder; Ernest T. Tolin
1969-01-01
INFORMAP (Information Necessary for Optimum Resource Management and Protection) is a computerized system under development for storing, manipulating, retrieving, and displaying data for fire planning and fire control. A prototype for planning applications has been developed and tested. It is programed in Fortran IV for the IBM 7040 computer, and displays information in...
Adaptive Computerized Instruction.
ERIC Educational Resources Information Center
Ray, Roger D.; And Others
1995-01-01
Describes an artificially intelligent multimedia computerized instruction system capable of developing a conceptual image of what a student is learning while the student is learning it. It focuses on principles of learning and adaptive behavioral control systems theory upon which the system is designed and demonstrates multiple user modes.…
Control systems for heating, ventilating, and air conditioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haines, R.W.
1977-01-01
Hundreds of ideas for designing and controlling sophisticated heating, ventilating and air conditioning (HVAC) systems are presented. Information is included on enthalpy control, energy conservation in HVAC systems, on solar heating, cooling and refrigeration systems, and on a self-draining water collector and heater. Computerized control systems and the economics of supervisory systems are discussed. Information is presented on computer system components, software, relevant terminology, and computerized security and fire reporting systems. Benefits of computer systems are explained, along with optimization techniques, data management, maintenance schedules, and energy consumption. A bibliography, glossaries of HVAC terminology, abbreviations, symbols, and a subject indexmore » are provided. (LCL)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya Lee; Spielman, Zachary Alexander; Rice, Brandon Charles
2016-04-01
This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.
NASA Technical Reports Server (NTRS)
Celino, V. A.
1977-01-01
An appendix providing the technical data required for computerized control and/or monitoring of selected MIST subsystems is presented. Specific computerized functions to be performed are as follows: (1) Control of the MIST heating load simulator and monitoring of the diesel engine generators' cooling system; (2) Control of the MIST heating load simulator and MIST heating subsystem including the heating load simulator; and (3) Control of the MIST air conditioning load simulator subsystem and the MIST air conditioning subsystem, including cold thermal storage and condenser water flows.
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2010 CFR
2010-04-01
...: “Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computerized Labor Monitoring System. 884.2800 Section 884.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
Computer Review Can Cut HVAC Energy Use
ERIC Educational Resources Information Center
McClure, Charles J. R.
1974-01-01
A computerized review of construction bidding documents, usually done by a consulting engineer, can reveal how much money it will cost to operate various alternative types of HVAC equipment over a school's lifetime. The review should include a computerized load calculation, energy systems flow diagram, control system analysis, and a computerized…
Wood transportation systems-a spin-off of a computerized information and mapping technique
William W. Phillips; Thomas J. Corcoran
1978-01-01
A computerized mapping system originally developed for planning the control of the spruce budworm in Maine has been extended into a tool for planning road net-work development and optimizing transportation costs. A budgetary process and a mathematical linear programming routine are used interactively with the mapping and information retrieval capabilities of the system...
ERIC Educational Resources Information Center
Veldkamp, Bernard P.; Verschoor, Angela J.; Eggen, Theo J. H. M.
2010-01-01
Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT) systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has…
Computerized procedures system
Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.
2010-10-12
An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.
A computerized test system for thermal-mechanical fatigue crack growth
NASA Technical Reports Server (NTRS)
Marchand, N.; Pelloux, R. M.
1986-01-01
A computerized testing system to measure fatigue crack growth under thermal-mechanical fatigue conditions is described. Built around a servohydraulic machine, the system is capable of a push-pull test under stress-controlled or strain-controlled conditions in the temperature range of 25 to 1050 C. Temperature and mechanical strain are independently controlled by the closed-loop system to simulate the complex inservice strain-temperature relationship. A d-c electrical potential method is used to measure crack growth rates. The correction procedure of the potential signal to take into account powerline and RF-induced noises and thermal changes is described. It is shown that the potential drop technique can be used for physical mechanism studies and for modelling crack tip processes.
A Feedback Control Strategy for Enhancing Item Selection Efficiency in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Weissman, Alexander
2006-01-01
A computerized adaptive test (CAT) may be modeled as a closed-loop system, where item selection is influenced by trait level ([theta]) estimation and vice versa. When discrepancies exist between an examinee's estimated and true [theta] levels, nonoptimal item selection is a likely result. Nevertheless, examinee response behavior consistent with…
Accuracy of a computerized clinical decision-support system for asthma assessment and management.
Hoeksema, Laura J; Bazzy-Asaad, Alia; Lomotan, Edwin A; Edmonds, Diana E; Ramírez-Garnica, Gabriela; Shiffman, Richard N; Horwitz, Leora I
2011-05-01
To evaluate the accuracy of a computerized clinical decision-support system (CDSS) designed to support assessment and management of pediatric asthma in a subspecialty clinic. Cohort study of all asthma visits to pediatric pulmonology from January to December, 2009. CDSS and physician assessments of asthma severity, control, and treatment step. Both the clinician and the computerized CDSS generated assessments of asthma control in 767/1032 (74.3%) return patients, assessments of asthma severity in 100/167 (59.9%) new patients, and recommendations for treatment step in 66/167 (39.5%) new patients. Clinicians agreed with the CDSS in 543/767 (70.8%) of control assessments, 37/100 (37%) of severity assessments, and 19/66 (29%) of step recommendations. External review classified 72% of control disagreements (21% of all control assessments), 56% of severity disagreements (37% of all severity assessments), and 76% of step disagreements (54% of all step recommendations) as CDSS errors. The remaining disagreements resulted from pulmonologist error or ambiguous guidelines. Many CDSS flaws, such as attributing all 'cough' to asthma, were easily remediable. Pediatric pulmonologists failed to follow guidelines in 8% of return visits and 18% of new visits. The authors relied on chart notes to determine clinical reasoning. Physicians may have changed their assessments after seeing CDSS recommendations. A computerized CDSS performed relatively accurately compared to clinicians for assessment of asthma control but was inaccurate for treatment. Pediatric pulmonologists failed to follow guideline-based care in a small proportion of patients.
A computerized compensator design algorithm with launch vehicle applications
NASA Technical Reports Server (NTRS)
Mitchell, J. R.; Mcdaniel, W. L., Jr.
1976-01-01
This short paper presents a computerized algorithm for the design of compensators for large launch vehicles. The algorithm is applicable to the design of compensators for linear, time-invariant, control systems with a plant possessing a single control input and multioutputs. The achievement of frequency response specifications is cast into a strict constraint mathematical programming format. An improved solution algorithm for solving this type of problem is given, along with the mathematical necessities for application to systems of the above type. A computer program, compensator improvement program (CIP), has been developed and applied to a pragmatic space-industry-related example.
ERIC Educational Resources Information Center
Osguthorpe, Russell T.; Li Chang, Linda
1988-01-01
A computerized symbol processor system using an Apple IIe computer and a Power Pad graphics tablet was tested with 22 nonspeaking, multiply disabled students. The students were taught to express themselves independently in writing, and they did significantly better than control students on measures of language comprehension and symbol recognition.…
An Integrated Computerized Triage System in the Emergency Department
Aronsky, Dominik; Jones, Ian; Raines, Bill; Hemphill, Robin; Mayberry, Scott R; Luther, Melissa A; Slusser, Ted
2008-01-01
Emergency department (ED) triage is a fast-paced process that prioritizes the allocation of limited health care resources to patients in greatest need. This paper describes the experiences with an integrated, computerized triage application. The system exchanges information with other information systems, including the ED patient tracking board, the longitudinal electronic medical record, the computerized provider order entry, and the medication reconciliation application. The application includes decision support capabilities such as assessing the patient’s acuity level, age-dependent alerts for vital signs, and clinical reminders. The browser-based system utilizes the institution’s controlled vocabulary, improves data completeness and quality, such as compliance with capturing required data elements and screening questions, initiates clinical processes, such as pneumococcal vaccination ordering, and reminders to start clinical pathways, issues alerts for clinical trial eligibility, and facilitates various reporting needs. The system has supported the triage documentation of >290,000 pediatric and adult patients. PMID:18999190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D.J.
In the last 100 years, power plant controls have evolved from manual operation and simple instruments to automatic state-of-the-art computerized control systems using smart instruments. This article traces the evolution of controls. The topics of the article include early control systems, developments in the early 20th century, Bailey controls, and developments in the late 20th century.
The VA Computerized Patient Record — A First Look
Anderson, Curtis L.; Meldrum, Kevin C.
1994-01-01
In support of its in-house DHCP Physician Order Entry/Results Reporting application, the VA is developing the first edition of a Computerized Patient Record. The system will feature a physician-oriented interface with real time, expert system-based order checking, a controlled vocabulary, a longitudinal repository of patient data, HL7 messaging support, a clinical reminder and warning system, and full integration with existing VA applications including lab, pharmacy, A/D/T, radiology, dietetics, surgery, vitals, allergy tracking, discharge summary, problem list, progress notes, consults, and online physician order entry. PMID:7949886
A Blood Bank Information Management System
Farmer, James J.
1982-01-01
A computerized Blood Bank Management system is described. Features include product oriented data input, inventory control reports, product utilization reports, rapid retrieval of individual patient reports. Relative benefits of the system are discussed.
39 CFR 501.15 - Computerized Meter Resetting System.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...
Design of a computerized, temperature-controlled, recirculating aquaria system
Widmer, A.M.; Carveth, C.J.; Keffler, J.W.; Bonar, Scott A.
2006-01-01
We built a recirculating aquaria system with computerized temperature control to maintain static temperatures, increase temperatures 1 ??C/day, and maintain diel temperature fluctuations up to 10 ??C. A LabVIEW program compared the temperature recorded by thermocouples in fish tanks to a desired set temperature and then calculated the amount of hot or cold water to add to tanks to reach or maintain the desired temperature. Intellifaucet?? three-way mixing valves controlled temperature of the input water and ensured that all fish tanks had the same turnover rate. The system was analyzed over a period of 50 days and was fully functional for 96% of that time. Six different temperature treatments were run simultaneously in 18, 72 L fish tanks and temperatures stayed within 0.5 ??C of set temperature. We used the system to determine the upper temperature tolerance of fishes, but it could be used in aquaculture, ecological studies, or other aquatic work where temperature control is required. ?? 2005 Elsevier B.V. All rights reserved.
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... computerized support enforcement systems. 307.15 Section 307.15 Public Welfare Regulations Relating to Public... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.15 Approval of advance planning documents for computerized support enforcement systems. (a...
Sled Control and Safety System
NASA Technical Reports Server (NTRS)
Forrest, L. J.
1982-01-01
Computerized system for controlling motion of linear-track accelerator applied to other automated equipment, such as numerically-controlled machine tools and robot manipulators on assembly lines. System controls motions of sled with sine-wave signal created digitally by microprocessor. Dynamic parameters of sled motion are monitored so sled may be stopped safely if malfunction occurs. Sled is capable of sinusoidal accelerations up to 0.5 g with 125-kg load.
Accounting Information Systems in Healthcare: A Review of the Literature.
Hammour, Hadal; Househ, Mowafa; Razzak, Hira Abdul
2017-01-01
As information technology progresses in Saudi Arabia, the manual accounting systems have become graduallyinadequate for decision needs. Subsequently, private and public healthcare divisions in Saudi Arabia perceive Computerized accounting information system (CAIS) as a vehicle to safeguard efficient and effective flow of information during the analysis, processes, and recording of financial data. Efficient and effective flow of information improvesthe decision making of staff, thereby improving the capability of health care sectors to reduce cost of the medical services.In this paper, we define computerized accounting systems from the point of view of health informatics. Also, the challenges and benefits of supporting CAIS applications in hospitals of Saudi Arabia. With these elements, we conclude that CAIS in Saudi Arabia can serve as a valuable tool for evaluating and controlling the cost of medical services in healthcare sectors. Supplementary education on the significance of having systems of computerized accounting within hospitals for nurses, doctors, and accountants with other health care staff is warranted in future.
Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.
Honaker, Julie A; Shepard, Neil T
2011-01-01
Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.
ERIC Educational Resources Information Center
Hsiao, Hsien-Sheng; Chen, Jyun-Chen; Hong, Kunde
2016-01-01
Technical and vocational education emphasizes the development and training of hand motor skills. However, some problems exist in the current career and aptitude tests in that they do not truly measure the hand motor skills. This study used the Nintendo Wii Remote Controller as the testing device in developing a set of computerized testing tools to…
Dexheimer, Judith W; Abramo, Thomas J; Arnold, Donald H; Johnson, Kevin; Shyr, Yu; Ye, Fei; Fan, Kang-Hsien; Patel, Neal; Aronsky, Dominik
2014-11-01
The use of evidence-based guidelines can improve the care for asthma patients. We implemented a computerized asthma management system in a pediatric emergency department (ED) to integrate national guidelines. Our objective was to determine whether patient eligibility identification by a probabilistic disease detection system (Bayesian network) combined with an asthma management system embedded in the workflow decreases time to disposition decision. We performed a prospective, randomized controlled trial in an urban, tertiary care pediatric ED. All patients 2-18 years of age presenting to the ED between October 2010 and February 2011 were screened for inclusion by the disease detection system. Patients identified to have an asthma exacerbation were randomized to intervention or control. For intervention patients, asthma management was computer-driven and workflow-integrated including computer-based asthma scoring in triage, and time-driven display of asthma-related reminders for re-scoring on the electronic patient status board combined with guideline-compliant order sets. Control patients received standard asthma management. The primary outcome measure was the time from triage to disposition decision. The Bayesian network identified 1339 patients with asthma exacerbations, of which 788 had an asthma diagnosis determined by an ED physician-established reference standard (positive predictive value 69.9%). The median time to disposition decision did not differ among the intervention (228 min; IQR=(141, 326)) and control group (223 min; IQR=(129, 316)); (p=0.362). The hospital admission rate was unchanged between intervention (25%) and control groups (26%); (p=0.867). ED length of stay did not differ among intervention (262 min; IQR=(165, 410)) and control group (247 min; IQR=(163, 379)); (p=0.818). The control and intervention groups were similar in regards to time to disposition; the computerized management system did not add additional wait time. The time to disposition decision did not change; however the management system integrated several different information systems to support clinicians' communication. Copyright © 2014. Published by Elsevier Ireland Ltd.
History of a Building Automation System.
ERIC Educational Resources Information Center
Martin, Anthony A.
1984-01-01
Having successfully used computer control in the solar-heated and cooled Terraset School, the Fairfax County, VA, Public Schools are now computerizing all their facilities. This article discusses the configuration and use of a countywide control system, reasons for the project's success, and problems of facility automation. (MCG)
ERIC Educational Resources Information Center
McLawhorn, Kerry
2001-01-01
Explains how the Scotland County School District in Laurinburg, North Carolina, tackled the problem of controlling building and room keys for fifteen K-12 schools and 7,000 students by marrying a computerized records management system for key tracking with a patented hardware system that produces keys that can't be duplicated. (GR)
Code of Federal Regulations, 2010 CFR
2010-10-01
... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...
21 CFR 111.20 - What design and construction requirements apply to your physical plant?
Code of Federal Regulations, 2011 CFR
2011-04-01
... surfaces, with microorganisms, chemicals, filth, or other extraneous material. Your physical plant must have, and you must use, separate or defined areas of adequate size or other control systems, such as computerized inventory controls or automated systems of separation, to prevent contamination and mixups of...
21 CFR 111.20 - What design and construction requirements apply to your physical plant?
Code of Federal Regulations, 2013 CFR
2013-04-01
... surfaces, with microorganisms, chemicals, filth, or other extraneous material. Your physical plant must have, and you must use, separate or defined areas of adequate size or other control systems, such as computerized inventory controls or automated systems of separation, to prevent contamination and mixups of...
A Save-Energy, Save-Money Program That Pays Off
ERIC Educational Resources Information Center
Embersits, John F.
1976-01-01
Suggested guidelines for energy saving on campus include a 3-phase plan: (1) Quick Fix--effective management of what you already have; (2) Refitting--modification of existing systems and installation of simple controls; (3) Systems Convert--installation of computerized controls, waste-heat recovery, solid-waste recovery utilization and other…
NASA Technical Reports Server (NTRS)
1984-01-01
Boeing Commercial Airplane Company's Flight Control Department engineers relied on Langley developed software package known as ORACLS to develop an advanced control synthesis package for both continuous and discrete control system. Package was used by Boeing for computerized analysis of new system designs. Resulting applications include a multiple input/output control system for the terrain-following navigation equipment of the Air Forces B-1 Bomber, and another for controlling in flight changes of wing camber on an experimental airplane. ORACLS is one of 1,300 computer programs available from COSMIC.
Uhm, Yo-Han; Yang, Dae-Jung
2018-02-01
[Purpose] The purpose of this study was to examine the effect of computerized postural control training using whole body vibration on lower limb muscle activity and cerebral cortical activation in acute stroke patients. [Subjects and Methods] Thirty stroke patients participated and were divided into groups of 10, a group of the computerized postural control training using whole body vibration (Group I), the computerized postural control training combined with aero step (Group II) and computerized postural control training (Group III). MP100 was used to measure lower limb muscle activity, and QEEG-8 was used to measure cerebral cortical activation. [Results] Comparison of muscle activity and cerebral cortical activation before and after intervention between groups showed that Group I had significant differences in lower limb muscle activity and cerebral cortical activation compared to Groups II and III. [Conclusion] This study showed that whole body vibration combined computerized postural control training is effective for improving muscle activity and cerebral cortex activity in stroke patients.
NASA Technical Reports Server (NTRS)
Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.
1981-01-01
The current status of the Active Controls Technology (ACT) for the advanced subsonic transport project is investigated through analysis of the systems technical data. Control systems technologies under examination include computerized reliability analysis, pitch axis fly by wire actuator, flaperon actuation system design trade study, control law synthesis and analysis, flutter mode control and gust load alleviation analysis, and implementation of alternative ACT systems. Extensive analysis of the computer techniques involved in each system is included.
Georgiou, Andrew; Prgomet, Mirela; Paoloni, Richard; Creswick, Nerida; Hordern, Antonia; Walter, Scott; Westbrook, Johanna
2013-06-01
We undertake a systematic review of the quantitative literature related to the effect of computerized provider order entry systems in the emergency department (ED). We searched MEDLINE, EMBASE, Inspec, CINAHL, and CPOE.org for English-language studies published between January 1990 and May 2011. We identified 1,063 articles, of which 22 met our inclusion criteria. Sixteen used a pre/post design; 2 were randomized controlled trials. Twelve studies reported outcomes related to patient flow/clinical work, 7 examined decision support systems, and 6 reported effects on patient safety. There were no studies that measured decision support systems and its effect on patient flow/clinical work. Computerized provider order entry was associated with an increase in time spent on computers (up to 16.2% for nurses and 11.3% for physicians), with no significant change in time spent on patient care. Computerized provider order entry with decision support systems was related to significant decreases in prescribing errors (ranging from 17 to 201 errors per 100 orders), potential adverse drug events (0.9 per 100 orders), and prescribing of excessive dosages (31% decrease for a targeted set of renal disease medications). There are tangible benefits associated with computerized provider order entry/decision support systems in the ED environment. Nevertheless, when considered as part of a framework of technical, clinical, and organizational components of the ED, the evidence base is neither consistent nor comprehensive. Multimethod research approaches (including qualitative research) can contribute to understanding of the multiple dimensions of ED care delivery, not as separate entities but as essential components of a highly integrated system of care. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1987-01-01
Skylab derived Heating System offers computerized control with an innovative voice synthesizer that literally allows the control unit to talk to the system user. It reports time of day, outside temperature and system temperature, and asks questions as to how the user wants the system programmed. Master Module collects energy from the Sun and either transfers it directly to the home water heater or stores it until needed.
Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.
Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S
2015-01-01
Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.
NASA Astrophysics Data System (ADS)
Anderson, Dallas W.; Hsu, Tung M.; Halpern, Steven J.; Honaker, Arnold
1993-07-01
The ProClosureTM System (PCS) consists of a low power 1.32micrometers Nd:YAG laser coupled to a handheld disposable fiber optic device. The system has been designed to perform a wide range of tissue welding applications such as cosmetic skin closure,vascular surgery, and minimally invasive surgical procedures normally performed with sutures and staples. Utilizing a wavelength for tissue fusion that is least distracted by medium in the surgical field coupled with a computerized delivery system allows for a more precise application (+/- 5%) of laser energy to the tissue. The study design involved the micro-surgical anastomosis of twenty Sprague-Dawley rats (vas deferens) and twenty-one Sprague-Dawley rats (femoral arteries). Each rat is its own contralateral control. Laser repair time is approximately one-third that of conventional suturing. Postoperative dissection and burst strength testing was conducted at day 0, 1, 7, and 14. At each postoperative interval, the mean leak/burst strength for laser-assisted closure v. control, was markedly higher. The precise application of energy fluence resulting from ProClosure's computerized system yields an initial strength and a fluid static seal that is superior to conventional suture closure.
A/C Interface: Expert Systems: Part II.
ERIC Educational Resources Information Center
Dessy, Raymond E., Ed.
1984-01-01
Discusses working implementations of artificial intelligence systems for chemical laboratory applications. They include expert systems for liquid chromatography, spectral analysis, instrument control of a totally computerized triple-quadrupole mass spectrometer, and the determination of the mineral constituents of a rock sample given the powder…
Freight Transportation Information Systems and Their Implications for R&D Policy
DOT National Transportation Integrated Search
1974-03-01
The current use of computerized management information and control systems in intercity freight transportation are examined. Each of the four modes (railroad, motor carrier, maritime and air cargo industries) is investigated. In each case, computer i...
Social and Labour Implications of Flexible Manufacturing Systems.
ERIC Educational Resources Information Center
Ebel, Karl-H.
1985-01-01
The flexible manufacturing system (FMS), a new way of organizing the production process by means of numerical control machines, robots, and computerized workstations, is described. The author examines some of the implications of FMS and the challenges it poses. (Author/CT)
Manufacturing Execution Systems: Examples of Performance Indicator and Operational Robustness Tools.
Gendre, Yannick; Waridel, Gérard; Guyon, Myrtille; Demuth, Jean-François; Guelpa, Hervé; Humbert, Thierry
Manufacturing Execution Systems (MES) are computerized systems used to measure production performance in terms of productivity, yield, and quality. In the first part, performance indicator and overall equipment effectiveness (OEE), process robustness tools and statistical process control are described. The second part details some tools to help process robustness and control by operators by preventing deviations from target control charts. MES was developed by Syngenta together with CIMO for automation.
NASA Astrophysics Data System (ADS)
Essa, Mohammed Sh.; Chiad, Bahaa T.; Shafeeq, Omer Sh.
2017-09-01
Thin Films of Copper Oxide (CuO) absorption layer have been deposited using home-made Fully Computerized Spray Pyrolysis Deposition system FCSPD on glass substrates, at the nozzle to substrate distance equal to 20,35 cm, and computerized spray mode (continues spray, macro-control spray). The substrate temperature has been kept at 450 °c with the optional user can enter temperature tolerance values ± 5 °C. Also that fixed molar concentration of 0.1 M, and 2D platform speed or deposition platform speed of 4mm/s. more than 1000 instruction program code, and specific design of graphical user interface GUI to fully control the deposition process and real-time monitoring and controlling the deposition temperature at every 200 ms. The changing in the temperature has been recorded during deposition processes, in addition to all deposition parameters. The films have been characterized to evaluate the thermal distribution over the X, Y movable hot plate, the structure and optical energy gap, thermal and temperature distribution exhibited a good and uniform distribution over 20 cm2 hot plate area, X-ray diffraction (XRD) measurement revealed that the films are polycrystalline in nature and can be assigned to monoclinic CuO structure. Optical band gap varies from 1.5-1.66 eV depending on deposition parameter.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENFORCEMENT SYSTEMS § 307.13 Security and confidentiality for computerized support enforcement systems in... systems in operation after October 1, 1997. (a) Information integrity and security. Have safeguards... 45 Public Welfare 2 2010-10-01 2010-10-01 false Security and confidentiality for computerized...
Hydrologic data-verification management program plan
Alexander, C.W.
1982-01-01
Data verification refers to the performance of quality control on hydrologic data that have been retrieved from the field and are being prepared for dissemination to water-data users. Water-data users now have access to computerized data files containing unpublished, unverified hydrologic data. Therefore, it is necessary to develop techniques and systems whereby the computer can perform some data-verification functions before the data are stored in user-accessible files. Computerized data-verification routines can be developed for this purpose. A single, unified concept describing master data-verification program using multiple special-purpose subroutines, and a screen file containing verification criteria, can probably be adapted to any type and size of computer-processing system. Some traditional manual-verification procedures can be adapted for computerized verification, but new procedures can also be developed that would take advantage of the powerful statistical tools and data-handling procedures available to the computer. Prototype data-verification systems should be developed for all three data-processing environments as soon as possible. The WATSTORE system probably affords the greatest opportunity for long-range research and testing of new verification subroutines. (USGS)
Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi
2011-12-01
Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.
The School Building Principal and Inventory Control: A Case for Computerization.
ERIC Educational Resources Information Center
Stronge, James
1987-01-01
General and special purpose database programs are appropriate for inventory control at the school building level. A fixed asset equipment inventory example illustrates the feasibility of computerized inventory control. (MLF)
Computer-Controlled HVAC -- at Low Cost
ERIC Educational Resources Information Center
American School and University, 1974
1974-01-01
By tying into a computerized building-automation network, Schaumburg High School, Illinois, slashed its energy consumption by one-third. The remotely connected computer controls the mechanical system for the high school as well as other buildings in the community, with the cost being shared by all. (Author)
Universal computer control system (UCCS) for space telerobots
NASA Technical Reports Server (NTRS)
Bejczy, Antal K.; Szakaly, Zoltan
1987-01-01
A universal computer control system (UCCS) is under development for all motor elements of a space telerobot. The basic hardware architecture and software design of UCCS are described, together with the rich motor sensing, control, and self-test capabilities of this all-computerized motor control system. UCCS is integrated into a multibus computer environment with direct interface to higher level control processors, uses pulsewidth multiplier power amplifiers, and one unit can control up to sixteen different motors simultaneously at a high I/O rate. UCCS performance capabilities are illustrated by a few data.
An automated library financial management system
NASA Technical Reports Server (NTRS)
Dueker, S.; Gustafson, L.
1977-01-01
A computerized library acquisition system developed for control of informational materials acquired at NASA Ames Research Center is described. The system monitors the acquisition of both library and individual researchers' orders and supplies detailed financial, statistical, and bibliographical information. Applicability for other libraries and the future availability of the program is discussed.
A Randomized Controlled Trial of the "Cool Teens" CD-ROM Computerized Program for Adolescent Anxiety
ERIC Educational Resources Information Center
Wuthrich, Viviana M.; Rapee, Ronald M.; Cunningham, Michael J.; Lyneham, Heidi J.; Hudson, Jennifer L.; Schniering, Carolyn A.
2012-01-01
Objective: Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This…
Computerized Torque Control for Large dc Motors
NASA Technical Reports Server (NTRS)
Willett, Richard M.; Carroll, Michael J.; Geiger, Ronald V.
1987-01-01
Speed and torque ranges in generator mode extended. System of shunt resistors, electronic switches, and pulse-width modulation controls torque exerted by large, three-phase, electronically commutated dc motor. Particularly useful for motor operating in generator mode because it extends operating range to low torque and high speed.
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?
Code of Federal Regulations, 2010 CFR
2010-10-01
... FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION... Acquisition Threshold; (c) Software and ownership rights. (1) All procurement and contract instruments must... Computerized Tribal IV-D System software or enhancements thereof and all associated documentation designed...
Generalized environmental control and life support system computer program (G1894), phase 3
NASA Technical Reports Server (NTRS)
Mcenulty, R. E.
1978-01-01
The work performed during Phase 3 of the Generalized Environmental Control Life Support System (ECLSS) Computer Program is reported. Phase 3 of this program covered the period from December 1977 to September 1978. The computerized simulation of the Shuttle Orbiter ECLSS was upgraded in the following areas: (1) the payload loop of the Shuttle simulation was completely recoded and checked out; (2) the Shuttle simulation water and freon loop initialization logic was simplified to permit easier program input for the user; (3) the computerized simulation was modified to accept the WASP subroutine, which is a subroutine to evaluate thermal properties of water and freon; (4) the 1108 operating system was upgraded by LEC; (5) the Shuttle simulation was modified to permit failure cases which simulate zero component flow values; and (6) the Shuttle SEPS version was modified and secure files were setup on the 1108 and 1110 systems to permit simulation runs to be made from remote terminals.
TFTR diagnostic control and data acquisition system
NASA Astrophysics Data System (ADS)
Sauthoff, N. R.; Daniels, R. E.
1985-05-01
General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.
TFTR diagnostic control and data acquisition system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division
1985-05-01
General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.
Implementation of real-time digital endoscopic image processing system
NASA Astrophysics Data System (ADS)
Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho
1997-10-01
Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.
Validation of a Self-Administered Computerized System to Detect Cognitive Impairment in Older Adults
Brinkman, Samuel D.; Reese, Robert J.; Norsworthy, Larry A.; Dellaria, Donna K.; Kinkade, Jacob W.; Benge, Jared; Brown, Kimberly; Ratka, Anna; Simpkins, James W.
2015-01-01
There is increasing interest in the development of economical and accurate approaches to identifying persons in the community who have mild, undetected cognitive impairments. Computerized assessment systems have been suggested as a viable approach to identifying these persons. The validity of a computerized assessment system for identification of memory and executive deficits in older individuals was evaluated in the current study. Volunteers (N = 235) completed a 3-hr battery of neuropsychological tests and a computerized cognitive assessment system. Participants were classified as impaired (n = 78) or unimpaired (n = 157) on the basis of the Mini Mental State Exam, Wechsler Memory Scale-III and the Trail Making Test (TMT), Part B. All six variables (three memory variables and three executive variables) derived from the computerized assessment differed significantly between groups in the expected direction. There was also evidence of temporal stability and concurrent validity. Application of computerized assessment systems for clinical practice and for identification of research participants is discussed in this article. PMID:25332303
Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M
To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
A computerized clinical decision support system as a means of implementing depression guidelines.
Trivedi, Madhukar H; Kern, Janet K; Grannemann, Bruce D; Altshuler, Kenneth Z; Sunderajan, Prabha
2004-08-01
The authors describe the history and current use of computerized systems for implementing treatment guidelines in general medicine as well as the development, testing, and early use of a computerized decision support system for depression treatment among "real-world" clinical settings in Texas. In 1999 health care experts from Europe and the United States met to confront the well-documented challenges of implementing treatment guidelines and to identify strategies for improvement. They suggested the integration of guidelines into computer systems that is incorporated into clinical workflow. Several studies have demonstrated improvements in physicians' adherence to guidelines when such guidelines are provided in a computerized format. Although computerized decision support systems are being used in many areas of medicine and have demonstrated improved patient outcomes, their use in psychiatric illness is limited. The authors designed and developed a computerized decision support system for the treatment of major depressive disorder by using evidence-based guidelines, transferring the knowledge gained from the Texas Medication Algorithm Project (TMAP). This computerized decision support system (CompTMAP) provides support in diagnosis, treatment, follow-up, and preventive care and can be incorporated into the clinical setting. CompTMAP has gone through extensive testing to ensure accuracy and reliability. Physician surveys have indicated a positive response to CompTMAP, although the sample was insufficient for statistical testing. CompTMAP is part of a new era of comprehensive computerized decision support systems that take advantage of advances in automation and provide more complete clinical support to physicians in clinical practice.
ERIC Educational Resources Information Center
Carriedo, Ruben; And Others
The San Diego Unified School District (California) began operating a computerized routing and scheduling system for its pupil transportation services at the beginning of the 1985-86 academic school year. The computerized system, provided by Ecotran Systems, Inc. (ECO) of Cleveland, Ohio experienced an inordinate number of difficulties. A…
Integration of a computerized two-finger gripper for robot workstation safety
NASA Technical Reports Server (NTRS)
Sneckenberger, John E.; Yoshikata, Kazuki
1988-01-01
A microprocessor-based controller has been developed that continuously monitors and adjusts the gripping force applied by a special two-finger gripper. This computerized force sensing gripper system enables the endeffector gripping action to be independently detected and corrected. The gripping force applied to a manipulated object is real-time monitored for problem situations, situations which can occur during both planned and errant robot arm manipulation. When unspecified force conditions occur at the gripper, the gripping force controller initiates specific reactions to cause dynamic corrections to the continuously variable gripping action. The force controller for this intelligent gripper has been interfaced to the controller of an industrial robot. The gripper and robot controllers communicate to accomplish the successful completion of normal gripper operations as well as unexpected hazardous situations. An example of an unexpected gripping condition would be the sudden deformation of the object being manipulated by the robot. The capabilities of the interfaced gripper-robot system to apply workstation safety measures (e.g., stop the robot) when these unexpected gripping effects occur have been assessed.
Embedded control system for computerized franking machine
NASA Astrophysics Data System (ADS)
Shi, W. M.; Zhang, L. B.; Xu, F.; Zhan, H. W.
2007-12-01
This paper presents a novel control system for franking machine. A methodology for operating a franking machine using the functional controls consisting of connection, configuration and franking electromechanical drive is studied. A set of enabling technologies to synthesize postage management software architectures driven microprocessor-based embedded systems is proposed. The cryptographic algorithm that calculates mail items is analyzed to enhance the postal indicia accountability and security. The study indicated that the franking machine is reliability, performance and flexibility in printing mail items.
A Blackboard-Based Dynamic Instructional Planner. ONR Final Report.
ERIC Educational Resources Information Center
Murray, William R.
Dynamic instructional planning was explored as a control mechanism for intelligent tutoring systems through the development of the Blackboard Instructional Planner--a blackboard software-based dynamic planner for computerized intelligent tutoring systems. The planner, designed to be generic to tutors teaching troubleshooting for complex physical…
An IP-Based Software System for Real-time, Closed Loop, Multi-Spacecraft Mission Simulations
NASA Technical Reports Server (NTRS)
Cary, Everett; Davis, George; Higinbotham, John; Burns, Richard; Hogie, Keith; Hallahan, Francis
2003-01-01
This viewgraph presentation provides information on the architecture of a computerized testbest for simulating Distributed Space Systems (DSS) for controlling spacecraft flying in formation. The presentation also discusses and diagrams the Distributed Synthesis Environment (DSE) for simulating and planning DSS missions.
ERIC Educational Resources Information Center
Maola, Joseph; Kane, Gary
1976-01-01
Subjects, who were Occupational Work Experience students, were randomly assigned to individual guidance from either a computerized occupational information system, to a counselor-based information system or to a control group. Results demonstrate a hierarchical learning effect: The computer group learned more than the counseled group, which…
Interactive computer graphics system for structural sizing and analysis of aircraft structures
NASA Technical Reports Server (NTRS)
Bendavid, D.; Pipano, A.; Raibstein, A.; Somekh, E.
1975-01-01
A computerized system for preliminary sizing and analysis of aircraft wing and fuselage structures was described. The system is based upon repeated application of analytical program modules, which are interactively interfaced and sequence-controlled during the iterative design process with the aid of design-oriented graphics software modules. The entire process is initiated and controlled via low-cost interactive graphics terminals driven by a remote computer in a time-sharing mode.
Kagan, Ilya; Cohen, Rachel; Fish, Miri; Mezare, Henia Perry
2014-01-01
This article describes the development and implementation of the Nursing Quality Indicators Scale and a quality control system for hospital nursing care, which allows universal access to all external and internal audit results, thus ensuring complete data transparency. Standardized indicators make departments' performance comparable. Key to the new system is nurses' self-audit and responsibility for making quality improvements at the ward level.
Proceedings of the international conference on cybernetics and societ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-01-01
This book presents the papers given at a conference on artificial intelligence, expert systems and knowledge bases. Topics considered at the conference included automating expert system development, modeling expert systems, causal maps, data covariances, robot vision, image processing, multiprocessors, parallel processing, VLSI structures, man-machine systems, human factors engineering, cognitive decision analysis, natural language, computerized control systems, and cybernetics.
Code of Federal Regulations, 2010 CFR
2010-10-01
... installation, operation, maintenance and enhancement of Computerized Tribal IV-D Systems and Office Automation... HEALTH AND HUMAN SERVICES COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.20 What are the conditions for funding the installation...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would emergency FFP be... AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.35 Under what circumstances would emergency FFP be available for Computerized Tribal IV-D Systems? (a...
2010-01-01
Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS), New Delhi has a computerized Health Management Information System (HMIS) since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors) and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR) 1674,217 (USD 35,622). Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213). The annual savings is around INR 894,283 (USD 11,924). Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision. PMID:21078203
SPS phase control system performance via analytical simulation
NASA Technical Reports Server (NTRS)
Lindsey, W. C.; Kantak, A. V.; Chie, C. M.; Booth, R. W. D.
1979-01-01
A solar power satellite transmission system which incorporates automatic beam forming, steering, and phase control is discussed. The phase control concept centers around the notation of an active retrodirective phased array as a means of pointing the beam to the appropriate spot on Earth. The transmitting antenna (spacetenna) directs the high power beam so that it focuses on the ground-based receiving antenna (rectenna). A combination of analysis and computerized simulation was conducted to determine the far field performance of the reference distribution system, and the beam forming and microwave power generating systems.
Liability for Invasions of Privacy by Physicians and Medical Data Systems
Watson, Bruce Lowell
1980-01-01
The disclosure of computerized medical care utilization data can injure patients and providers. Liability for these disclosures depends upon: defendants' intent, the existence of such precautions as information quality control systems and express contractual waivers of privacy rights, and the applicability of certain legal privileges permitting such disclosures.
ERIC Educational Resources Information Center
Payne, Arnold, Comp.
This publication presents performance flow charts and other accompanying forms that are elements of an economical computerized continuing inventory system. The system described here is intended to serve school systems as an adequate fixed asset system and to provide a computerized inventory model that offers support for costs of future educational…
1986-09-01
differentiation between the systems. This study will investigate an appropriate Order Processing and Management Information System (OP&MIS) to link base-level...methodology: 1. Reviewed the current order processing and information model of the TUAF Logistics System. (centralized-manual model) 2. Described the...RDS program’s order processing and information system. (centralized-computerized model) 3. Described the order irocessing and information system of
Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method.
Ceyhanli, Kadir T; Orucoglu, Hasan; Erdilek, Necdet; Turkun, Murat; Akdağ, Mustafa S
2015-12-01
The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage.
Fogel, Sandy L; Baker, Christopher C
2013-04-01
The use of computerized decision support systems (CDSS) in glucose control for critically ill surgical patients has been reported in both diabetic and nondiabetic patients. Prospective studies evaluating its effect on glucose control are, however, lacking. The objective of this study was to evaluate patient-specific computerized IV insulin dosing on blood glucose levels (BGLs) by comparing patients treated pre-CDSS with those treated post-CDSS. A prospective study was performed in 4 surgical ICUs and 1 progressive care unit comparing patient data pre- and post-implementation of CDSS. The primary outcomes measures were the impact of the CDSS on glycemic control in this population and on reducing the incidence of severe hypoglycemia. Data on 1,682 patient admissions were evaluated, which corresponded to 73,290 BGLs post-CDSS compared with 44,972 BGLs pre-CDSS. The percentage of hyperglycemic events improved, with BGLs of >150 mg/dL decreasing by 50% compared with 6-month historical controls during the 18-month study period from July 2010 through December 2011. This was true for all 5 units individually (p < 0.0001, by one sample sign test). In addition, severe hypoglycemia (defined as BGL <40 mg/dL) decreased from 1% to 0.05% after implementing CDSS (p < 0.0001 by 2-sided binomial test). Patients whose BGLs were managed using CDSS were statistically significantly more likely to have a glucose reading under control (<150 mg/dL) than in the 6-month historical controls and to avoid serious hypoglycemia (p < 0.0001). Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu
2009-10-01
The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.
NASA Technical Reports Server (NTRS)
Maiocco, F. R.; Hume, J. P.
1976-01-01
A system's approach is outlined in the paper to assist facility and Plant Engineers improve their organization's data management system. The six basic steps identified may appear somewhat simple; however, adequate planning, proper resources, and the involvement of management will determine the success of a computerized facility management data base. Helpful suggestions are noted throughout the paper to insure the development of a practical computerized data management system.
Haynes, R Brian; Wilczynski, Nancy L
2010-02-05
Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Data will be summarized using descriptive summary measures, including proportions for categorical variables and means for continuous variables. Univariable and multivariable logistic regression models will be used to investigate associations between outcomes of interest and study specific covariates. When reporting results from individual studies, we will cite the measures of association and p-values reported in the studies. If appropriate for groups of studies with similar features, we will conduct meta-analyses. A decision-maker-researcher partnership provides a model for systematic reviews that may foster knowledge translation and uptake.
Computerized system for translating a torch head
NASA Technical Reports Server (NTRS)
Wall, W. A., Jr.; Ives, R. E.; Bruce, M. M., Jr.; Pryor, P. P., Jr.; Gard, L. H. (Inventor)
1978-01-01
The system provides a constant travel speed along a contoured workpiece. It has a driven skate characterized by an elongated bed, with a pair of independently pivoted trucks connected to the bed for support. The trucks are mounted on a contoured track of arbitrary configuration in a mutually spaced relation. An axially extensible torch head manipulator arm is mounted on the bed of the carriage and projects perpendicular from the midportion. The torch head is mounted at its distal end. A real-time computerized control drive subsystem is used to advance the skate along the track of a variable rate for maintaining a constant speed for the torch head tip, and to position the torch axis relative to a preset angle to the workpiece.
ERIC Educational Resources Information Center
Davis, Laurie Laughlin
2004-01-01
Choosing a strategy for controlling item exposure has become an integral part of test development for computerized adaptive testing (CAT). This study investigated the performance of six procedures for controlling item exposure in a series of simulated CATs under the generalized partial credit model. In addition to a no-exposure control baseline…
MIUS Integration and Subsystem Test (MIST) data system
NASA Technical Reports Server (NTRS)
Pringle, L. M.
1977-01-01
A data system for use in testing integrated subsystems of a modular integrated utility system (MIUS) is presented. The MIUS integration and subsystem test (MIST) data system is reviewed from its conception through its checkout and operation as the controlling portion of the MIST facility. The MIST data system provides a real time monitoring and control function that allows for complete evaluation of the performance of the mechanical and electrical subsystems, as well as controls the operation of the various components of the system. In addition to the aforementioned capabilities, the MIST data system provides computerized control of test operations such that minimum manpower is necessary to set up, operate, and shut down subsystems during test periods.
Terrell, Kevin M; Perkins, Anthony J; Hui, Siu L; Callahan, Christopher M; Dexter, Paul R; Miller, Douglas K
2010-12-01
Emergency physicians prescribe several discharge medications that require dosage adjustment for patients with renal disease. The hypothesis for this research was that decision support in a computerized physician order entry system would reduce the rate of excessive medication dosing for patients with renal impairment. This was a randomized, controlled trial in an academic emergency department (ED), in which computerized physician order entry was used to write all prescriptions for patients being discharged from the ED. The sample included 42 physicians who were randomized to the intervention (21 physicians) or control (21 physicians) group. The intervention was decision support that provided dosing recommendations for targeted medications for patients aged 18 years and older when the patient's estimated creatinine clearance level was below the threshold for dosage adjustment. The primary outcome was the proportion of targeted medications that were excessively dosed. For 2,783 (46%) of the 6,015 patient visits, the decision support had sufficient information to estimate the patient's creatinine clearance level. The average age of these patients was 46 years, 1,768 (64%) were women, and 1,523 (55%) were black. Decision support was provided 73 times to physicians in the intervention group, who excessively dosed 31 (43%) prescriptions. In comparison, control physicians excessively dosed a significantly larger proportion of medications: 34 of 46, 74% (effect size=31%; 95% confidence interval 14% to 49%; P=.001). Emergency physicians often prescribed excessive doses of medications that require dosage adjustment for renal impairment. Computerized physician order entry with decision support significantly reduced excessive dosing of targeted medications. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
A First Life with Computerized Business Simulations
ERIC Educational Resources Information Center
Thavikulwat, Precha
2011-01-01
The author discusses the theoretical lens, origins, and environment of his work on computerized business simulations. Key ideas that inform his work include the two dimensions (control and interaction) of computerized simulation, the two ways of representing a natural process (phenotypical and genotypical) in a simulation, which he defines as a…
Forest control and regulation ... a comparison of traditional methods and alternatives
LeRoy C. Hennes; Michael J. Irving; Daniel I. Navon
1971-01-01
Two traditional techniques of forest control and regulation-formulas and area-volume check-are compared to linear programing, as used in a new computerized planning system called Timber Resource Allocation Method ( Timber RAM). Inventory data from a National Forest in California illustrate how each technique is used. The traditional methods are simpler to apply and...
Cardiopulmonary data-acquisition system
NASA Technical Reports Server (NTRS)
Crosier, W. G.; Reed, R. A.
1981-01-01
Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.
Controlling Item Exposure Conditional on Ability in Computerized Adaptive Testing.
ERIC Educational Resources Information Center
Stocking, Martha L.; Lewis, Charles
1998-01-01
Ensuring item and pool security in a continuous testing environment is explored through a new method of controlling exposure rate of items conditional on ability level in computerized testing. Properties of this conditional control on exposure rate, when used in conjunction with a particular adaptive testing algorithm, are explored using simulated…
Computer versus paper system for recognition and management of sepsis in surgical intensive care.
Croft, Chasen A; Moore, Frederick A; Efron, Philip A; Marker, Peggy S; Gabrielli, Andrea; Westhoff, Lynn S; Lottenberg, Lawrence; Jordan, Janeen; Klink, Victoria; Sailors, R Matthew; McKinley, Bruce A
2014-02-01
A system to provide surveillance, diagnosis, and protocolized management of surgical intensive care unit (SICU) sepsis was undertaken as a performance improvement project. A system for sepsis management was implemented for SICU patients using paper followed by a computerized system. The hypothesis was that the computerized system would be associated with improved process and outcomes. A system was designed to provide early recognition and guide patient-specific management of sepsis including (1) modified early warning signs-sepsis recognition score (MEWS-SRS; summative point score of ranges of vital signs, mental status, white blood cell count; after every 4 hours) by bedside nurse; (2) suspected site assessment (vascular access, lung, abdomen, urinary tract, soft tissue, other) at bedside by physician or extender; (3) sepsis management protocol (replicable, point-of-care decisions) at bedside by nurse, physician, and extender. The system was implemented first using paper and then a computerized system. Sepsis severity was defined using standard criteria. In January to May 2012, a paper system was used to manage 77 consecutive sepsis encounters (3.9 ± 0.5 cases per week) in 65 patients (77% male; age, 53 ± 2 years). In June to December 2012, a computerized system was used to manage 132 consecutive sepsis encounters (4.4 ± 0.4 cases per week) in 119 patients (63% male; age, 58 ± 2 years). MEWS-SRS elicited 683 site assessments, and 201 had sepsis diagnosis and protocol management. The predominant site of infection was abdomen (paper, 58%; computer, 53%). Recognition of early sepsis tended to occur more using the computerized system (paper, 23%; computer, 35%). Hospital mortality rate for surgical ICU sepsis (paper, 20%; computer, 14%) was less with the computerized system. A computerized sepsis management system improves care process and outcome. Early sepsis is recognized and managed with greater frequency compared with severe sepsis or septic shock. The system has a beneficial effect as a clinical standard of care for SICU patients. Therapeutic study, level III.
Nemanic, Sarah; Mills, Serena; Viehdorfer, Matt; Clark, Terri; Bailey, Mike
Teaching the anatomy of the canine larynx and hyoid apparatus is challenging because dissection disassembles and/or damages these structures, making it difficult to understand their three-dimensional (3D) anatomy and spatial interrelationships. This study assessed the effectiveness of an interactive, computerized 3D tutorial for teaching the anatomy of the canine larynx and hyoid apparatus using a randomized control design with students enrolled in the first-year professional program at Oregon State University College of Veterinary Medicine. All first-year students from 2 consecutive years were eligible. All students received the traditional methods of didactic teaching and dissection to learn the anatomy of the canine larynx and hyoid apparatus, after which they were divided into two statistically equal groups based on their cumulative anatomy test scores from the prior term. The tutorial group received an interactive, computerized tutorial developed by the investigators containing 3D images of the canine larynx and hyoid apparatus, while the control group received the same 3D images without the computerized tutorial. Both groups received the same post-learning assessment and survey. Sixty-three first-year students participated in the study, 28 in the tutorial group, and 35 in the control group. Post-learning assessment and survey scores were both significantly higher among students in the computerized tutorial group than those in the control group. This study demonstrates that a 3D computerized tutorial is more effective in teaching the anatomy of the canine hyoid apparatus and larynx than 3D images without a tutorial. Students likewise rated their learning experience higher when using the 3D computerized tutorial.
A randomized controlled trial of the Cool Teens CD-ROM computerized program for adolescent anxiety.
Wuthrich, Viviana M; Rapee, Ronald M; Cunningham, Michael J; Lyneham, Heidi J; Hudson, Jennifer L; Schniering, Carolyn A
2012-03-01
Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This paper describes the results of a small randomized controlled trial of the Cool Teens program for adolescent anxiety, and examines potential barriers to treatment and user preferences of computerized technology in this population. Forty-three adolescents with a primary diagnosis of anxiety were randomly allocated to the Cool Teens program, a 12-week computerized cognitive-behavioral therapy program for anxiety management, or a 12-week wait list. Effects on symptoms, negative thoughts, and life interference were assessed at post-treatment and 3-month follow-up, based on diagnosis as well as self and maternal report. Using mixed-model analyses, at post-treatment and follow-up assessments, adolescents in the Cool Teens condition, compared with those on the wait list, were found to have significant reductions in the total number of anxiety disorders, the severity of the primary anxiety disorder, and the average severity for all disorders. These results were matched by significant reductions in mother and child questionnaire reports of anxiety, internalizing symptoms, automatic thoughts, and life interference. Further few barriers to treatment were found, and user preferences indicated that the computerized treatment was well suited to adolescents with anxiety. The Cool Teens program is efficacious for treatment of adolescent anxiety. Clinical trial registration information-A randomized controlled trial of the Cool Teens computerized program for anxious adolescents compared with waist list; http://www.anzctr.org.au; ACTRN12611000508976. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.
The Impact of Computerization on Archival Finding Aids: A RAMP Study.
ERIC Educational Resources Information Center
Kitching, Christopher
This report is based on a questionnaire sent to 32 selected National Archives and on interviews with archivists from eight countries. Geared to the needs of developing countries, the report covers: (1) the impact of computerization on finding aids; (2) advantages and problems of computerization, including enhanced archival control, integration of…
Human Factors and Technical Considerations for a Computerized Operator Support System Prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulrich, Thomas Anthony; Lew, Roger Thomas; Medema, Heather Dawne
2015-09-01
A prototype computerized operator support system (COSS) has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Departmentmore » of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment. A COSS demonstration scenario has been developed for the prototype involving the Chemical & Volume Control System (CVCS) of the PWR simulator. It involves a primary coolant leak outside of containment that would require tripping the reactor if not mitigated in a very short timeframe. The COSS prototype presents a series of operator screens that provide the needed information and soft controls to successfully mitigate the event.« less
F-15 HiDEC taxi on ramp at sunrise
1991-09-23
NASA's highly modified F-15A (Serial #71-0287) used for digital electronic flight and engine control systems research, at sunrise on the ramp at the Dryden Flight Research Facility, Edwards, California. The F-15 was called the HIDEC (Highly Integrated Digital Electronic Control) flight facility. Research programs flown on the testbed vehicle have demonstrated improved rates of climb, fuel savings, and engine thrust by optimizing systems performance. The aircraft also tested and evaluated a computerized self-repairing flight control system for the Air Force that detects damaged or failed flight control surfaces. The system then reconfigures undamaged control surfaces so the mission can continue or the aircraft is landed safely.
Fathima, Mariam; Peiris, David; Naik-Panvelkar, Pradnya; Saini, Bandana; Armour, Carol Lyn
2014-12-02
The use of computerized clinical decision support systems may improve the diagnosis and ongoing management of chronic diseases, which requires recurrent visits to multiple health professionals, disease and medication monitoring and modification of patient behavior. The aim of this review was to systematically review randomized controlled trials evaluating the effectiveness of computerized clinical decision systems (CCDSS) in the care of people with asthma and COPD. Randomized controlled trials published between 2003 and 2013 were searched using multiple electronic databases Medline, EMBASE, CINAHL, IPA, Informit, PsychINFO, Compendex, and Cochrane Clinical Controlled Trials Register databases. To be included, RCTs had to evaluate the role of the CCDSSs for asthma and/or COPD in primary care. Nineteen studies representing 16 RCTs met our inclusion criteria. The majority of the trials were conducted in patients with asthma. Study quality was generally high. Meta-analysis was not conducted because of methodological and clinical heterogeneity. The use of CCDSS improved asthma and COPD care in 14 of the 19 studies reviewed (74%). Nine of the nineteen studies showed statistically significant (p < 0.05) improvement in the primary outcomes measured. The majority of the studies evaluated health care process measures as their primary outcomes (10/19). Evidence supports the effectiveness of CCDSS in the care of people with asthma. However there is very little information of its use in COPD care. Although there is considerable improvement in the health care process measures and clinical outcomes through the use of CCDSSs, its effects on user workload and efficiency, safety, costs of care, provider and patient satisfaction remain understudied.
Code of Federal Regulations, 2014 CFR
2014-10-01
... comprehensive Tribal IV-D agencies must have in place to ensure the security and privacy of Computerized Tribal... ensure the security and privacy of Computerized Tribal IV-D Systems and Office Automation? (a..., accuracy, completeness, access to, and use of data in the Computerized Tribal IV-D System and Office...
Wellman, G S; Hammond, R L; Talmage, R
2001-10-01
A secondary data-reporting system used to scan the archives of a hospital's automated storage and distribution cabinets (ASDCs) for indications of controlled-substance diversion is described. ASDCs, which allow access to multiple doses of the same medication at one time, use drug count verification to ensure complete audits and disposition tracking. Because an ASDC may interpret inappropriate removal of a medication as a normal transaction, users of ASDCs should have a comprehensive plan for detecting and investigating controlled-substance diversion. Monitoring for and detecting diversion can be difficult and time-consuming, given the limited report-generating features of many ASDCs. Managers at an 800-bed hospital used report-writing software to address these problems. This application interfaces with the hospital's computer system and generates customized reports. The monthly activity recapitulation report lists each user of the ASDCs and gives a summary of all the controlled-substance transactions for those users for the time period specified. The monthly summary report provides the backbone of the surveillance system and identifies situations that require further audit and review. This report provides a summary of each user's activity for a specific medication for the time period specified. The detailed summary report allows for efficient review of specific transactions before there is a decision to conduct a chart review. This report identifies all ASDC controlled-substance transactions associated with a user. A computerized report-generating system identifies instances of inappropriate removal of controlled substances from a hospital's ASDCs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katipamula, Srinivas; Gowri, Krishnan; Hernandez, George
This paper describes one such reference process that can be deployed to provide continuous automated conditioned-based maintenance management for buildings that have BIM, a building automation system (BAS) and a computerized maintenance management software (CMMS) systems. The process can be deployed using an open source transactional network platform, VOLTTRON™, designed for distributed sensing and controls and supports both energy efficiency and grid services.
Evaluation of an ontology-based system for computerized cognitive rehabilitation.
Alloni, Anna; Quaglini, Silvana; Panzarasa, Silvia; Sinforiani, Elena; Bernini, Sara
2018-07-01
This paper describes the results of a randomized clinical trial about the effectiveness of a computerized rehabilitation treatment on a sample of 31 patients affected by Parkinson disease. Computerized exercises were administered by the therapists to the intervention group (n = 17) through the CoRe tool, which automatically generates a big variety of exercises leveraging on a stimuli set (words, sounds and images) organized into a dedicated ontology. A battery of standard neuropsychological tests was performed for patients' assessment at baseline, after the treatment (that lasted 1 month), and after 6 months from the treatment stop. The control group underwent a sham intervention. Results show a statistically significant clinical benefit from computerized rehabilitation with respect to sham treatment. For the intervention group, response time and response accuracy were integrated into a weighted score that accounts also for the specific cognitive burden of each exercise. Differently from the control group, the majority of patients in the intervention group showed an improvement in that score, more marked in the first week of treatment, and which lasts for the entire treatment period, which could account both for a quick learning effect and for an improvement of cognitive conditions. Good usability of CoRe, already observed in previous studies, was confirmed by the present trial, where the percentage of protocol completion in the intervention group is very high (all but one patient are above 90%). The CoRe system showed to be effective to improve some cognitive abilities in patients with Parkinson disease. However, after the end of the training, the benefit is hardly maintained over time. These findings support the implementation of CoRe in the clinical routine and the continuation of the treatment after discharge through the use of a homecare version of the system. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1976-01-01
Analytic techniques have been developed for detecting and identifying abrupt changes in dynamic systems. The GLR technique monitors the output of the Kalman filter and searches for the time that the failure occured, thus allowing it to be sensitive to new data and consequently increasing the chances for fast system recovery following detection of a failure. All failure detections are based on functional redundancy. Performance tests of the F-8 aircraft flight control system and computerized modelling of the technique are presented.
Systems and Methods for Peak-Seeking Control
NASA Technical Reports Server (NTRS)
Ryan, John J (Inventor); Speyer, Jason L (Inventor)
2013-01-01
A computerized system and method for peak-seeking-control that uses a unique Kalman filter design to optimize a control loop, in real time, to either maximize or minimize a performance function of a physical object ("plant"). The system and method achieves more accurate and efficient peak-seeking-control by using a time-varying Kalman filter to estimate both the performance function gradient (slope) and Hessian (curvature) based on direct position measurements of the plant, and does not rely upon modeling the plant response to persistent excitation. The system and method can be naturally applied in various applications in which plant performance functions have multiple independent parameters, and it does not depend upon frequency separation to distinguish between system dimensions.
Stabilometer Computerized Analog Recording System for Studying Gross Motor Skill Learning
ERIC Educational Resources Information Center
Chasey, William C., Jr.; And Others
1976-01-01
The stabilometer computerized analog recording system (SCARS) provides for storing analog and digital information on a single channel audio tape recorder at lower cost and greater versatility than other systems. (MB)
An Analysis of Minimum System Requirements to Support Computerized Adaptive Testing.
1986-09-01
adaptive test ( CAT ); adaptive test ing A;4SRAC:’ (Continue on reverie of necessary and ident4f by block number) % This pape-r discusses the minimum system...requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing, establishes a set of...discusses the minimum system requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing
NASA Technical Reports Server (NTRS)
Rumbaugh, Duane M.; Washburn, David A.; Savage-Rumbaugh, E. S.; Hopkins, William D.; Richardson, W. K.
1991-01-01
Automation of a computerized test system for comparative primate research is shown to improve the results of learning in standard paradigms. A mediational paradigm is used to determine the degree to which criterion in the learning-set testing reflects stimulus-response associative or mediational learning. Rhesus monkeys are shown to exhibit positive transfer as the criterion levels are shifted upwards, and the effectiveness of the computerized testing system is confirmed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCann, D.; White, D.
This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.
Pre-Engineered Buildings and School Construction.
ERIC Educational Resources Information Center
Jurney, Douglas M.
1979-01-01
A preengineered building has the advantages of factory production and computerized quality control. Insulation efficiency and a roofing system that enables the entire roof membrane to react a full two inches to any temperature-induced movement are two of the innovations of preengineered building research. (Author/MLF)
Computerized Manufacturing Automation. Employment, Education, and the Workplace. Summary.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Office of Technology Assessment.
The application of programmable automation (PA) offers new opportunities to enhance and streamline manufacturing processes. Five PA technologies are examined in this report: computer-aided design, robots, numerically controlled machine tools, flexible manufacturing systems, and computer-integrated manufacturing. Each technology is in a relatively…
[Some approaches to the countermeasure system for a mars exploration mission].
Kozlovskaia, I B; Egorov, A D; Son'kin, V D
2010-01-01
In article discussed physiological and methodical principles of the organization of training process and his (its) computerization during Martian flight in conditions of autonomous activity of the crew, providing interaction with onboard medical means, self-maintained by crew of the their health, performance of preventive measures, diagnostic studies and, in case of necessity, carrying out of treatment. In super long autonomous flights essentially become complicated the control of ground experts over of crew members conditions, that testifies to necessity of a computerization of control process by a state of health of crew, including carrying out of preventive actions. The situation becomes complicated impossibility of reception and transfer aboard the necessary information in real time and emergency returning of crew to the Earth. In these conditions realization of problems of physical preventive maintenance should be solved by means of the onboard automated expert system, providing management by trainings of each crew members, directed on optimization of their psychophysical condition.
ERIC Educational Resources Information Center
Davis, Laurie Laughlin; Pastor, Dena A.; Dodd, Barbara G.; Chiang, Claire; Fitzpatrick, Steven J.
2003-01-01
Examined the effectiveness of the Sympson-Hetter technique and rotated content balancing relative to no exposure control and no content rotation conditions in a computerized adaptive testing system based on the partial credit model. Simulation results show the Sympson-Hetter technique can be used with minimal impact on measurement precision,…
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would FFP be suspended or... SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.30 Under what circumstances would FFP be suspended or disallowed in the costs of Computerized Tribal IV-D...
Looking ahead in systems engineering
NASA Technical Reports Server (NTRS)
Feigenbaum, Donald S.
1966-01-01
Five areas that are discussed in this paper are: (1) the technological characteristics of systems engineering; (2) the analytical techniques that are giving modern systems work its capability and power; (3) the management, economics, and effectiveness dimensions that now frame the modern systems field; (4) systems engineering's future impact upon automation, computerization and managerial decision-making in industry - and upon aerospace and weapons systems in government and the military; and (5) modern systems engineering's partnership with modern quality control and reliability.
Computerized Training of Working Memory in Children with ADHD-A Randomized, Controlled Trial
ERIC Educational Resources Information Center
Klingberg, Torkel; Fernell, Elisabeth; Olesen, Pernille J.; Johnson, Mats; Gustafsson, Per; Dahlstrom, Kerstin; Gillberg, Christopher G.; Forssberg, Hans; Westerberg, Helena
2005-01-01
Objective: Deficits in executive functioning, including working memory (WM) deficits, have been suggested to be important in attention-deficit/hyperactivity disorder (ADHD). During 2002 to 2003, the authors conducted a multicenter, randomized, controlled, double-blind trial to investigate the effect of improving WM by computerized, systematic…
Computerized Numerical Control Test Item Bank.
ERIC Educational Resources Information Center
Reneau, Fred; And Others
This guide contains 285 test items for use in teaching a course in computerized numerical control. All test items were reviewed, revised, and validated by incumbent workers and subject matter instructors. Items are provided for assessing student achievement in such aspects of programming and planning, setting up, and operating machines with…
Process and control systems for composites manufacturing
NASA Technical Reports Server (NTRS)
Tsiang, T. H.; Wanamaker, John L.
1992-01-01
A precise control of composite material processing would not only improve part quality, but it would also directly reduce the overall manufacturing cost. The development and incorporation of sensors will help to generate real-time information for material processing relationships and equipment characteristics. In the present work, the thermocouple, pressure transducer, and dielectrometer technologies were investigated. The monitoring sensors were integrated with the computerized control system in three non-autoclave fabrication techniques: hot-press, self contained tool (self heating and pressurizing), and pressure vessel). The sensors were implemented in the parts and tools.
Precision-Based Item Selection for Exposure Control in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Carroll, Ian A.
2017-01-01
Item exposure control is, relative to adaptive testing, a nascent concept that has emerged only in the last two to three decades on an academic basis as a practical issue in high-stakes computerized adaptive tests. This study aims to implement a new strategy in item exposure control by incorporating the standard error of the ability estimate into…
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J
2015-11-01
The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.
Computerized Adaptive Testing System Design: Preliminary Design Considerations.
ERIC Educational Resources Information Center
Croll, Paul R.
A functional design model for a computerized adaptive testing (CAT) system was developed and presented through a series of hierarchy plus input-process-output (HIPO) diagrams. System functions were translated into system structure: specifically, into 34 software components. Implementation of the design in a physical system was addressed through…
Designing a Computerized Presentation Center.
ERIC Educational Resources Information Center
Christopher, Doris A.
1995-01-01
The Office Systems and Business Education Department at California State University (Los Angeles) developed a computerized presentation center, with multimedia classrooms and a multipurpose room, where students learn computerized presentation design skills, faculty can develop materials for class, and local business can do videoconferencing and…
Tourtellotte, W G; Lawrence, D T; Getting, P A; Van Hoesen, G W
1989-07-01
This report describes a computerized microscope charting system based on the IBM personal computer or compatible. Stepping motors are used to control the movement of the microscope stage and to encode its position by hand manipulation of a joystick. Tissue section contours and the location of cells labeled with various compounds are stored by the computer, plotted at any magnification and manipulated into composites created from several charted sections. The system has many advantages: (1) it is based on an industry standardized computer that is affordable and familiar; (2) compact and commercially available stepping motor microprocessors control the stage movement. These controllers increase reliability, simplify implementation, and increase efficiency by relieving the computer of time consuming control tasks; (3) the system has an interactive graphics interface allowing the operator to view the image during data collection. Regions of the graphics display can be enlarged during the charting process to provide higher resolution and increased accuracy; (4) finally, the digitized data are stored at 0.5 micron resolution and can be routed directly to a multi-pen plotter or exported to a computer-aided design (CAD) program to generate a publication-quality montage composed of several computerized chartings. The system provides a useful tool for the acquisition and qualitative analysis of data representing stained cells or chemical markers in tissue. The modular design, together with data storage at high resolution, allows for potential analytical enhancements involving planimetric, stereologic and 3-D serial section reconstruction.
Cost Estimation and Control for Flight Systems
NASA Technical Reports Server (NTRS)
Hammond, Walter E.; Vanhook, Michael E. (Technical Monitor)
2002-01-01
Good program management practices, cost analysis, cost estimation, and cost control for aerospace flight systems are interrelated and depend upon each other. The best cost control process cannot overcome poor design or poor systems trades that lead to the wrong approach. The project needs robust Technical, Schedule, Cost, Risk, and Cost Risk practices before it can incorporate adequate Cost Control. Cost analysis both precedes and follows cost estimation -- the two are closely coupled with each other and with Risk analysis. Parametric cost estimating relationships and computerized models are most often used. NASA has learned some valuable lessons in controlling cost problems, and recommends use of a summary Project Manager's checklist as shown here.
1977-01-26
Sisteme Matematicheskogo Obespecheniya YeS EVM [ Applied Programs in the Software System for the Unified System of Computers], by A. Ye. Fateyev, A. I...computerized systems are most effective in large production complexes , in which the level of utilization of computers can be as high as 500,000...performance of these tasks could be furthered by the complex introduction of electronic computers in automated control systems. The creation of ASU
[Computerized medical record: deontology and legislation].
Allaert, F A; Dusserre, L
1996-02-01
Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.
An overview of selected information storage and retrieval issues in computerized document processing
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Ihebuzor, Valentine U.
1984-01-01
The rapid development of computerized information storage and retrieval techniques has introduced the possibility of extending the word processing concept to document processing. A major advantage of computerized document processing is the relief of the tedious task of manual editing and composition usually encountered by traditional publishers through the immense speed and storage capacity of computers. Furthermore, computerized document processing provides an author with centralized control, the lack of which is a handicap of the traditional publishing operation. A survey of some computerized document processing techniques is presented with emphasis on related information storage and retrieval issues. String matching algorithms are considered central to document information storage and retrieval and are also discussed.
Predicting Language Proficiency Based on the Use of Multimedia Interfaces for Transcription Tasks.
ERIC Educational Resources Information Center
Crosby, Martha E.; And Others
1996-01-01
Describes a controlled experiment conducted to determine the differences between native and nonnative speakers' strategies for transcribing dialogs, from the simple to the complex. Results confirmed that there were significant differences among three categories of the users' interactions with a computerized transcription system. (seven references)…
A Prudent Access Control Behavioral Intention Model for the Healthcare Domain
ERIC Educational Resources Information Center
Mussa, Constance C.
2011-01-01
In recent years, many health care organizations have begun to take advantage of computerized information systems to facilitate more effective and efficient management and processing of information. However, commensurate with the vastly innovative enhancements that computer technology has contributed to traditional paper-based health care…
Under Lock and Key: Preventing Campus Theft of Electronic Equipment.
ERIC Educational Resources Information Center
Harrison, J. Phil
1996-01-01
A discussion of computer theft prevention on college campuses looks at a variety of elements in electronic equipment security, including the extent of the problem, physical antitheft products, computerized access, control of key access, alarm systems, competent security personnel, lighting, use of layers of protection, and increasing…
Unesco Integrated Documentation Network; Computerized Documentation System (CDS).
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Paris (France). Dept. of Documentation, Libraries, and Archives.
Intended for use by the Computerized Documentation System (CDS), the Unesco version of ISIS (Integrated Set of Information Systems)--originally developed by the International Labour Organization--was developed in 1975 and named CDS/ISIS. This system has a comprehensive collection of programs for input, management, and output, running in batch or…
Computerized Adaptive Screening Test (CAST): Development for Use in Military Recruiting Stations
1984-01-01
testing ( CAT ) 20. ABSTRACT (Continuo on rover .. efdo II neco .. ., ond Identity bJ’ 11/oclr -llor) The Computerized Adaptive Screening Test (CAST...effort is in progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the military entrance...U.S. Marine Corps) has been designated as lead service for CAT system development; and the Navy Personnel Research and Development Center, as lead
Application of a computerized environmental information system to master and sector planning
NASA Technical Reports Server (NTRS)
Stewart, J. C.
1978-01-01
A computerized composite mapping system developed as an aid in the land use decision making process is described. Emphasis is placed on consideration of the environment in urban planning. The presence of alluvium, shallow bedrock, surface water, and vegetation growth are among the environmental factors considered. An analysis of the Shady Grove Sector planning is presented as an example of the use of computerized composite mapping for long range planning.
Computerized Systems for Collecting Real-Time Observational Data.
ERIC Educational Resources Information Center
Kahng, SungWoo; Iwata, Brian
1998-01-01
A survey of 15 developers of computerized real-time observation systems found many systems have incorporated laptop or handheld computers as well as bar-code scanners. Most systems used IBM-compatible software, and ranged from free to complete systems costing more than $1,500. Data analysis programs were included with most programs. (Author/CR)
Computerization and its contribution to care quality improvement: the nurses' perspective.
Kagan, Ilya; Fish, Miri; Farkash-Fink, Naomi; Barnoy, Sivia
2014-12-01
Despite the widely held belief that the computerization of hospital medical systems contributes to improved patient care management, especially in the context of ordering medications and record keeping, extensive study of the attitudes of medical staff to computerization has found them to be negative. The views of nursing staff have been barely studied and so are unclear. The study reported here investigated the association between nurses' current computer use and skills, the extent of their involvement in quality control and improvement activities on the ward and their perception of the contribution of computerization to improving nursing care. The study was made in the context of a Joint Commission International Accreditation (JCIA) in a large tertiary medical center in Israel. The perception of the role of leadership commitment in the success of a quality initiative was also tested for. Two convenience samples were drawn from 33 clinical wards and units of the medical center. They were questioned at two time points, one before the JCIA and a second after JCIA completion. Of all nurses (N=489), 89 were paired to allow analysis of the study data in a before-and-after design. Thus, this study built three data sets: a pre-JCIA set, a post-JCIA set and a paired sample who completed the questionnaire both before and after JCIA. Data were collected by structured self-administered anonymous questionnaire. After the JCIA the participants ranked the role of leadership in quality improvement, the extent of their own quality control activity, and the contribution of computers to quality improvement higher than before the JCIA. Significant Pearson correlations were found showing that the higher the rating given to quality improvement leadership the more nurses reported quality improvement activities undertaken by them and the higher nurses rated the impact of computerization on the quality of care. In a regression analysis quality improvement leadership and computer use/skills accounted for 30% of the variance in the perceived contribution of computerization to quality improvement. (a) The present study is the first to show a relationship between organizational leadership and computer use by nurses for the purpose of improving clinical care. (b) The nurses' appreciation of the contribution computerization can make to data management and to clinical care quality improvement were both increased by the JCI accreditation process. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Supporting Patient Care in the Emergency Department with a Computerized Whiteboard System
Aronsky, Dominik; Jones, Ian; Lanaghan, Kevin; Slovis, Corey M.
2008-01-01
Efficient information management and communication within the emergency department (ED) is essential to providing timely and high-quality patient care. The ED whiteboard (census board) usually serves as an ED’s central access point for operational and patient-related information. This article describes the design, functionality, and experiences with a computerized ED whiteboard, which has the ability to display relevant operational and patient-related information in real time. Embedded functionality, additional whiteboard views, and the integration with ED and institutional information system components, such as the computerized patient record or the provider order entry system, provide rapid access to more detailed information. As an information center, the computerized whiteboard supports our ED environment not only for providing patient care, but also for operational, educational, and research activities. PMID:18096913
Computerized Adaptive Testing (CAT): A User Manual
1984-03-12
NPRDC TR 84-32 COMPUTERIZED ADAPTIVE TESTING ( CAT ): A USER MANUAL Susan Hardwick Lawrence Eastman Ross Cooper Rehab Group, Incorporated San...a ~EI’IOD COVIRED COMPUTERIZED ADAPTIVE TESTING ( CAT ) Final Report Aug 1981-June 1982 A USER MANUAL 1. ~l:l’t,ORMINCI ORCI. RE~ORT NUM.I:R 62-83...II nee• .. _, entl ldentll)’ ,,. llloclr _,.,) A joint-service effort is underway to develop a computerized adaptive testing ( CAT ) system and to
Computerized database management system for breast cancer patients.
Sim, Kok Swee; Chong, Sze Siang; Tso, Chih Ping; Nia, Mohsen Esmaeili; Chong, Aun Kee; Abbas, Siti Fathimah
2014-01-01
Data analysis based on breast cancer risk factors such as age, race, breastfeeding, hormone replacement therapy, family history, and obesity was conducted on breast cancer patients using a new enhanced computerized database management system. My Structural Query Language (MySQL) is selected as the application for database management system to store the patient data collected from hospitals in Malaysia. An automatic calculation tool is embedded in this system to assist the data analysis. The results are plotted automatically and a user-friendly graphical user interface is developed that can control the MySQL database. Case studies show breast cancer incidence rate is highest among Malay women, followed by Chinese and Indian. The peak age for breast cancer incidence is from 50 to 59 years old. Results suggest that the chance of developing breast cancer is increased in older women, and reduced with breastfeeding practice. The weight status might affect the breast cancer risk differently. Additional studies are needed to confirm these findings.
Computerized Diagnostic Testing: Problems and Possibilities.
ERIC Educational Resources Information Center
McArthur, David L.
The use of computers to build diagnostic inferences is explored in two contexts. In computerized monitoring of liquid oxygen systems for the space shuttle, diagnoses are exact because they can be derived within a world which is closed. In computerized classroom testing of reading comprehension, programs deliver a constrained form of adaptive…
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
Evaluation of the Salt Lake City Computerized Rider Information System
DOT National Transportation Integrated Search
1985-11-01
The Utah Transit Authority (UTA) Computerized Rider Information System (CRIS) project involved the installation of an automated telephone service to quickly provide bus stop-specific schedule and service information to residents throughout the Author...
An overview of Virginia's computerized crash records systems.
DOT National Transportation Integrated Search
1995-01-01
This report identifies the various components of Virginia's computerized crash records systems and explains how these components process crash data. Emphasis has been placed on recording information that was previously not documented. Most of the sta...
Patel, Minal R; Vichich, Jennifer; Lang, Ian; Lin, Jessica; Zheng, Kai
2017-04-01
The introduction of health information technology systems, electronic health records in particular, is changing the nature of how clinicians interact with patients. Lack of knowledge remains on how best to integrate such systems in the exam room. The purpose of this systematic review was to (1) distill "best" behavioral and communication practices recommended in the literature for clinicians when interacting with patients in the presence of computerized systems during a clinical encounter, (2) weigh the evidence of each recommendation, and (3) rank evidence-based recommendations for electronic health record communication training initiatives for clinicians. We conducted a literature search of 6 databases, resulting in 52 articles included in the analysis. We extracted information such as study setting, research design, sample, findings, and implications. Recommendations were distilled based on consistent support for behavioral and communication practices across studies. Eight behavioral and communication practices received strong support of evidence in the literature and included specific aspects of using computerized systems to facilitate conversation and transparency in the exam room, such as spatial (re)organization of the exam room, maintaining nonverbal communication, and specific techniques that integrate the computerized system into the visit and engage the patient. Four practices, although patient-centered, have received insufficient evidence to date. We developed an evidence base of best practices for clinicians to maintain patient-centered communications in the presence of computerized systems in the exam room. Further work includes development and empirical evaluation of evidence-based guidelines to better integrate computerized systems into clinical care. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Detecting errors and anomalies in computerized materials control and accountability databases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteson, R.; Hench, K.; Yarbro, T.
The Automated MC and A Database Assessment project is aimed at improving anomaly and error detection in materials control and accountability (MC and A) databases and increasing confidence in the data that they contain. Anomalous data resulting in poor categorization of nuclear material inventories greatly reduces the value of the database information to users. Therefore it is essential that MC and A data be assessed periodically for anomalies or errors. Anomaly detection can identify errors in databases and thus provide assurance of the integrity of data. An expert system has been developed at Los Alamos National Laboratory that examines thesemore » large databases for anomalous or erroneous data. For several years, MC and A subject matter experts at Los Alamos have been using this automated system to examine the large amounts of accountability data that the Los Alamos Plutonium Facility generates. These data are collected and managed by the Material Accountability and Safeguards System, a near-real-time computerized nuclear material accountability and safeguards system. This year they have expanded the user base, customizing the anomaly detector for the varying requirements of different groups of users. This paper describes the progress in customizing the expert systems to the needs of the users of the data and reports on their results.« less
Comparative study of computerized dynamic posturography and the SwayStar system in healthy subjects.
Faraldo-García, Ana; Santos-Pérez, Sofía; Crujeiras, Rosa; Labella-Caballero, Torcuato; Soto-Varela, Andrés
2012-03-01
For healthy subjects, posturography and SwayStar™ results are basically comparable, when they are obtained under the same sensory stimulation conditions. However, the management of the information and the mathematical analyses in the two systems are not comparable. Postural control represents man's ability to maintain the center of pressures inside the limits of stability. Posturography is a set of techniques that objectively studies and quantifies the postural control. The present study analyzed the different parameters of the dynamic computerized posturography and SwayStar systems related to balance, to determine whether the results of the two systems in the same healthy subject are equivalent. Seventy healthy individuals, with a mean age of 44.9 years, were homogeneously divided into seven age groups. Postural studies with a Neurocom(®) Smart Balance Master posturography platform (sensorial organization test), with the SwayStar(®) system (14 tests), and another sensorial organization test were recorded simultaneously with the two posturographs. The Pearson correlation test was used for the statistical study (p < 0.05). Comparison of the independent records showed correlation only in the Romberg position with eyes closed on a normal surface and in the Romberg position with open eyes on moving/foam surface. We found correlation for all conditions when simultaneously recorded.
Mazeh, Haggi; Samet, Yacov; Abu-Wasel, Bassam; Beglaibter, Nahum; Grinbaum, Ronit; Cohen, Tzeela; Pinto, Meir; Hamburger, Tamar; Freund, Herbert R; Nissan, Aviram
2009-03-01
Uniform and accurate reporting of surgical complications is the basis for quality control. We developed a computerized system for reporting and grading surgical complications in colorectal surgery. This study was conducted to evaluate this computerized reporting system. A retrospective chart review was conducted of all surgical complications in patients who underwent resection of the colon or rectum at our institution between the years 1999 and 2004 (n = 408). All complications were recorded using the computerized reporting system and compared with complications reported in the literature. Elective operations were performed in 75.7% of patients, and 24.3% required emergency operations. Of the 408 patients in the study, 239 (58.6%) had an uneventful recovery without complications. At least 1 complication was recorded in 169 (41.4%) patients. Grades 1 and 2 complications were recorded in 83 (20.3%) and 105 (25.7%) patients, respectively, requiring observation or medical treatment only, and 59 patients (14.5%) had grades 3 to 5 complications. The three leading complications were surgical site infection, intraabdominal abscess, and hemorrhage requiring blood transfusion. The grades 3 to 5 complication rate was within the range described in the literature, and the rate of grades 1 and 2 complications was substantially higher. These grades 1 and 2 complications were associated with a substantially longer hospital stay. This novel complication reporting system was found feasible and proved to have a higher sensitivity for recording minor but meaningful complications that tend to prolong hospital stay.
Root elongation against a constant force: experiment with a computerized feedback-controlled device
NASA Technical Reports Server (NTRS)
Kuzeja, P. S.; Lintilhac, P. M.; Wei, C.
2001-01-01
Axial force was applied to the root tip of corn (Zea mays L. cv. Merit) seedlings using a computerized, feedback-controlled mechanical device. The system's feedback capability allowed continuous control of a constant tip load, and the attached displacement transducer provided the time course of root elongation. Loads up to 7.5 g decreased the root elongation rate by 0.13 mm h-1 g-1, but loads 7.5 to 17.5 g decreased the growth rate by only 0.04 mm h-1 g-1. Loads higher than 18 g stopped root elongation completely. Measurement of the cross-sectional areas of the root tips indicated that the 18 g load had applied about 0.98 MPa of axial pressure to the root, thereby exceeding the root's ability to respond with increased turgor pressure. Recorded time-lapse images of loaded roots showed that radial thickening (swelling) occurred behind the root cap, whose cross-sectional area increased with tip load.
The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.
Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne
2014-06-01
Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The Effects of Computerized Information Systems on Juvenile Courts
ERIC Educational Resources Information Center
Albrecht, Gary L.
1976-01-01
Organizational theorists alternatively hypothesized that computerized information systems (CIS) will produce no necessary changes, centralization, or decentralization in juvenile courts. This hypothesis is supported by the results of a four year study on the phenomenon. Suggestions are offered for improving the juvenile judicial system through…
MMPI-2 and MMPI-A Computerized Interpretation: An Adjunct to Quality Mental Health Service.
ERIC Educational Resources Information Center
Phelps, LeAdelle
1994-01-01
Provides reviews of computerized scoring and interpretive systems for the Minnesota Multiphasic Personality Inventory (MMPI-2 and MMPI-A): Caldwell Report, the Psychological Assessment Resources MMPI-2 Interpretive System, and the National Computer Systems Programs. Concludes that when used appropriately, such scoring systems enhance a counselor's…
Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.
De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil
2015-12-01
This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.
Ten Brinke, Lisanne F; Best, John R; Crockett, Rachel A; Liu-Ambrose, Teresa
2018-01-30
Given the world's aging population, it is important to identify strategies that promote healthy cognitive aging and minimize cognitive decline. Currently, no curative pharmaceutical therapy exists for cognitive impairment and dementia. As a result, there is much interest in lifestyle approaches. Specifically, complex mental activity, such as cognitive training, may be a promising method to combat cognitive decline in older adults. As such, the industry of commercial computerized cognitive training (CCT) applications has rapidly grown in the last decade. However, the efficacy of these commercial products is largely not established. Moreover, exercise is a recognized strategy for promoting cognitive outcomes in older adults and may augment the efficacy of computerized cognitive training applications. Therefore, we propose a proof-of-concept randomized controlled trial (RCT) to examine the effect of a commercial CCT program in community-dwelling older adults. An 8-week RCT to examine the effect of a commercial CCT program, alone and preceded by a 15-min brisk walk, on cognitive function and explore the underlying neural mechanisms in adults aged 65-85 years old. Participants will be randomized to one of three intervention groups: 1) Computerized cognitive training (FBT); 2) A 15-min brisk walk followed by computerized cognitive training (Ex-FBT); or 3) A combination of educational classes, sham cognitive training, and balanced and tone exercises (active control, BAT). Participants in all intervention groups will attend three one-hour classes per week over the course of the intervention. Participants will be assessed at baseline, trial completion, and 1-year post study completion (1-year follow-up). If results from this study show benefits for cognition at trial completion, CCT programs, alone or in combination with walking, might be a strategy to promote healthy cognitive aging in older adults. In addition, results from the 1-year follow-up measurement could provide important information regarding the long-term benefits of these CCT programs. ClinicalTrials.gov Protocol Registration System: NCT02564809; registered September 1, 2015.
45 CFR 307.0 - Scope of this part.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) The requirement for computerized support enforcement systems; (b) The functional requirements that a statewide computerized support enforcement system must meet; (c) Security and confidentiality requirements... to approving an advance planning document (APD); (e) The requirements and procedures for the...
Interactive experimenters' planning procedures and mission control
NASA Technical Reports Server (NTRS)
Desjardins, R. L.
1973-01-01
The computerized mission control and planning system routinely generates a 24-hour schedule in one hour of operator time by including time dimensions into experimental planning procedures. Planning is validated interactively as it is being generated segment by segment in the frame of specific event times. The planner simply points a light pen at the time mark of interest on the time line for entering specific event times into the schedule.
Oak Ridge Computerized Hierarchical Information System (ORCHIS) status report, July 1973
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brooks, A.A.
1974-01-01
This report summarizes the concepts, software, and contents of the Oak Ridge Computerized Hierarchical Information System. This data analysis and text processing system was developed as an integrated, comprehensive information processing capability to meet the needs of an on-going multidisciplinary research and development organization. (auth)
The Computerized Adaptive Testing System Development Project.
ERIC Educational Resources Information Center
McBride, James R.; Sympson, J. B.
The Computerized Adaptive Testing (CAT) project is a joint Armed Services coordinated effort to develop and evaluate a system for automated, adaptive administration of the Armed Services Vocational Aptitude Battery (ASVAB). The CAT is a system for administering personnel tests that differs from conventional test administration in two major…
1980-06-01
COMPUTERIZED GENERAL PURPOSE INFORMATION MANAGEMENT SYSTEM (SELGE.M) TO KEDICALLY IMPORTANT ARTHROPODS (DIPTERA: CULICIDAE) Annual Report Terry L. Erwin June...GENERAL PURPOSE INFORMATION MANAGEMENT SYSTEM Annual--1 September 1979- (SEIGEM) TO MEDICALLY ThWORTANT ARTHROPODS 30 May 1980 (DIPTERA: CULICIDAE) 6
1981-08-01
APPLICATION OF A COMPUTERIZED GENERAL PURPOSE INFORMATION MANAGEMENT SYSTEM (SELGEM) TO MEDICALLY IMPORTANT ARTHROPODS (DIPTERA: CULICIDAE) I’ Annual Report...Bailey. 1981. Application of a com- puterized information management system (SELGEM) to medically important arthropods (National Museum Mosquito
Howell, David R; Osternig, Louis R; Chou, Li-Shan
2018-02-16
To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits alone. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Kwag, Koren H.; Lytras, Theodore; Bertizzolo, Lorenzo; Brandt, Linn; Pecoraro, Valentina; Rigon, Giulio; Vaona, Alberto; Ruggiero, Francesca; Mangia, Massimo; Iorio, Alfonso; Kunnamo, Ilkka; Bonovas, Stefanos
2014-01-01
We systematically reviewed randomized controlled trials (RCTs) assessing the effectiveness of computerized decision support systems (CDSSs) featuring rule- or algorithm-based software integrated with electronic health records (EHRs) and evidence-based knowledge. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Cochrane Database of Abstracts of Reviews of Effects. Information on system design, capabilities, acquisition, implementation context, and effects on mortality, morbidity, and economic outcomes were extracted. Twenty-eight RCTs were included. CDSS use did not affect mortality (16 trials, 37395 patients; 2282 deaths; risk ratio [RR] = 0.96; 95% confidence interval [CI] = 0.85, 1.08; I2 = 41%). A statistically significant effect was evident in the prevention of morbidity, any disease (9 RCTs; 13868 patients; RR = 0.82; 95% CI = 0.68, 0.99; I2 = 64%), but selective outcome reporting or publication bias cannot be excluded. We observed differences for costs and health service utilization, although these were often small in magnitude. Across clinical settings, new generation CDSSs integrated with EHRs do not affect mortality and might moderately improve morbidity outcomes. PMID:25322302
ERIC Educational Resources Information Center
Gullo, Shirna R.
2014-01-01
Computerized testing may be one solution to enhance performance on the curricular Health Education Systems Inc. (HESI) exam and the National Council Licensure Exam for Registered Nurses (NCLEX-RN). Due to the integration of improved technological processes and procedures in healthcare for computerized documentation and electronicmedical records,…
Computerized Management of Physical Plant Services.
ERIC Educational Resources Information Center
Hawkey, Earl W.; Kleinpeter, Joseph
Outlining the major areas to be considered when deciding whether or not to computerize physical plant services in higher education institutions, the author points out the shortcomings of manual record keeping systems. He gives five factors to consider when deciding to computerize: (1) time and money, (2) extent of operation, (3) current and future…
Enhancing GDOT's Computerized Pavement Condition Evaluation System for Pavement Condition Survey
DOT National Transportation Integrated Search
2017-09-01
The Computerized Pavement Condition Evaluation System (COPACES) is a software tool that has been used by the Georgia Department of Transportation (GDOT) for its statewide pavement condition survey since the late 1990s. The previous version was releas...
ERIC Educational Resources Information Center
Vasarhelyi, Paul
The new data retrieval system for the social sciences which has recently been installed in the UNESCO Secretariat in Paris is described in this comprehensive report. The computerized system is designed to facilitate the existing storage systems in the circulation of information, data retrieval, and indexing services. Basically, this report…
Moe, Aubrey M; Breitborde, Nicholas J K; Shakeel, Mohammed K; Gallagher, Colin J; Docherty, Nancy M
2016-04-01
Disordered speech and language deficits are well-documented in schizophrenia-spectrum disorders. Researchers often assess speech samples using manualized rating systems, though recently computerized language assessment methods have been used more frequently in the study of speech from people with schizophrenia. Most typically, these computerized assessments measure aspects of expressivity (i.e., pause durations, prosody) or use word-count technology; less attention has focused on similar methods that can capture more sophisticated aspects of linguistic complexity (e.g., idea density). The primary objective of the present study was to assess idea density - via a computerized measure - in the life-story narratives of people with schizophrenia (n=32) compared to a group of community control participants (n=15). In the schizophrenia group, we also examined associations between idea density, narrative qualities rated via a manualized measure, and psychiatric symptoms. Our findings indicate that idea density is diminished in individuals with schizophrenia compared to controls. Further, our results suggest that though people with schizophrenia with richer idea density tended to have more developed insight into illness, they also had higher levels of depression, anxiety, and avolition. Implications of these results and suggestions for future research are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Visual monitoring of autonomous life sciences experimentation
NASA Technical Reports Server (NTRS)
Blank, G. E.; Martin, W. N.
1987-01-01
The design and implementation of a computerized visual monitoring system to aid in the monitoring and control of life sciences experiments on board a space station was investigated. A likely multiprocessor design was chosen, a plausible life science experiment with which to work was defined, the theoretical issues involved in the programming of a visual monitoring system for the experiment was considered on the multiprocessor, a system for monitoring the experiment was designed, and simulations of such a system was implemented on a network of Apollo workstations.
A Data Management System for Multi-Phase Case-Control Studies
Gibeau, Joanne M.; Steinfeldt, Lois C.; Stine, Mark J.; Tullis, Katherine V.; Lynch, H. Keith
1983-01-01
The design of a computerized system for the management of data in multi-phase epidemiologic case-control studies is described. Typical study phases include case-control selection, abstracting of data from medical records, and interview of study subjects or next of kin. In consultation with project personnel, requirements for the system were established: integration of data from all study phases into one data base, accurate follow-up of subjects through the study, sophisticated data editing capabilities, ready accessibility of specified programs to project personnel, and generation of current status and exception reports for project managment. SIR (Scientific Information Retrieval), a commercially available data base management system, was selected as the foundation of this system. The system forms a comprehensive data management system applicable to many types of public health research studies.
Interrupted Time Series Versus Statistical Process Control in Quality Improvement Projects.
Andersson Hagiwara, Magnus; Andersson Gäre, Boel; Elg, Mattias
2016-01-01
To measure the effect of quality improvement interventions, it is appropriate to use analysis methods that measure data over time. Examples of such methods include statistical process control analysis and interrupted time series with segmented regression analysis. This article compares the use of statistical process control analysis and interrupted time series with segmented regression analysis for evaluating the longitudinal effects of quality improvement interventions, using an example study on an evaluation of a computerized decision support system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to conduct automated data processing and recordkeeping activities through Office Automation... IV-D Systems and office automation? 310.5 Section 310.5 Public Welfare Regulations Relating to Public... AUTOMATION Requirements for Computerized Tribal IV-D Systems and Office Automation § 310.5 What options are...
The Development of COBOL and RPG Instructional Modules to Audit Computerized Accounting Systems.
ERIC Educational Resources Information Center
Skudrna, Vincent J.
1982-01-01
Details steps involved (as found in the literature) in the systems approach to design and develop instruction in order to provide a rationale for the development of instructional modules in COBOL and RPG to teach accounting students how to audit computerized accounting systems. Outlines of two modules are appended. (EAO)
ERIC Educational Resources Information Center
Hallam, Teresa A.; Hallam, Stephen F.
2009-01-01
Imagine a computerized learning management system that enables teachers to deliver pertinent learning materials to students. Lectures are prerecorded and made available to download from the learning management system. If all their lectures were prerecorded, what would teachers do in the classroom? Classroom time could be used to coordinate…
1982-07-01
GENERAL PURPOSE INFORMATION MANAGEMENT SYSTEM (SELGEM) TO MEDICALLY 0 IMPORTANT ARTHROPODS (DIPTERA: CULICIDAE) oAnnual Report Terry L. Erwin July...APPLICATION OF A COMPUTERIZED GENERAL PURPOSE Annual Report INFORMATION MANAGEMENT SYSTEM (SELGEM) TO July 1981 to June 1982 MEDICALLY IMPORTANT ARTHROPODS
1984-08-01
4 MOSQUITO INFORMATION MANAGEMENT PROJECT (MIMP): *APPLICATION OF A COMPUTERIZED GENERAL PURPOSE I INFORMATION MANAGEMENT SYSTEM (SELGEM) TO...1983 to August 1984 INFORMATION MANAGEMENT SYSTEM (SELGEM) TO MEDI- 6 EFRIGOG EOTNME * CALLY IMPORTANT ARTHROPODS (DIPTERA: CULICIDAE) .v PEnRMN OG
Computerized Information and Support for Patients with Breast Cancer or HIV Infection.
ERIC Educational Resources Information Center
Rolnick, Sharon J.; Owens, Betta; Botta, Renee; Sathe, Laurie; Hawkins, Robert; Cooper, Leah; Kelley, Mary; Gustafson, David
1999-01-01
Use of the Comprehensive Health Enhancement Support System, a computerized information system, by patients with breast cancer or HIV was compared. Groups differed in the frequency of access and use of certain aspects (e.g., discussion groups). Identification of patient concerns provided useful information for system improvements. (SK)
Khammarnia, Mohammad; Sharifian, Roxana; Zand, Farid; Keshtkaran, Ali; Barati, Omid
2016-09-01
This study aimed to identify the functional requirements of computerized provider order entry software and design this software in Iran. This study was conducted using review documentation, interview, and focus group discussions in Shiraz University of Medical Sciences, as the medical pole in Iran, in 2013-2015. The study sample consisted of physicians (n = 12) and nurses (n = 2) in the largest hospital in the southern part of Iran and information technology experts (n = 5) in Shiraz University of Medical Sciences. Functional requirements of the computerized provider order entry system were examined in three phases. Finally, the functional requirements were distributed in four levels, and accordingly, the computerized provider order entry software was designed. The software had seven main dimensions: (1) data entry, (2) drug interaction management system, (3) warning system, (4) treatment services, (5) ability to write in software, (6) reporting from all sections of the software, and (7) technical capabilities of the software. The nurses and physicians emphasized quick access to the computerized provider order entry software, order prescription section, and applicability of the software. The software had some items that had not been mentioned in other studies. Ultimately, the software was designed by a company specializing in hospital information systems in Iran. This study was the first specific investigation of computerized provider order entry software design in Iran. Based on the results, it is suggested that this software be implemented in hospitals.
ERIC Educational Resources Information Center
Chang, Frank Tien-Jin
Computerized school administration has become one of the most crucial innovations in vocational education in Taiwan in the Republic of China. As these educators begin to design or purchase computerized information systems for their own schools, they must first define their specific information needs. Next, they should pay attention to…
40 CFR 51.358 - Test equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...
COMPUTERIZED FGD BYPRODUCT PRODUCTION AND MARKETING SYSTEM: USERS MANUAL
The users manual describes a computerized system--consisting of a number of integrated programs, models, and data bases--that has been developed to compare the costs of power plant strategies designed to meet clean air regulations. It describes the data bases, programs, and proce...
40 CFR 51.358 - Test equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...
Documentation of validity for the AT-SAT computerized test battery. Volume 2
DOT National Transportation Integrated Search
2001-03-01
This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...
Documentation of validity for the AT-SAT computerized test battery. Volume 1
DOT National Transportation Integrated Search
2001-03-01
This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...
The Print and Computer Enlargement System--PACE. Final Report.
ERIC Educational Resources Information Center
Morford, Ronald A.
The Print and Computer Enlargement (PACE) System is being designed as a portable computerized reading and writing system that enables a low-vision person to read regular print and then create and edit text using large-print computerized output. The design goal was to develop a system that: weighed no more than 12 pounds so it could be easily…
SYN-OP-SYS™: A Computerized Management Information System for Quality Assurance and Risk Management
Thomas, David J.; Weiner, Jayne; Lippincott, Ronald C.
1985-01-01
SYN·OP·SYS™ is a computerized management information system for quality assurance and risk management. Computer software for the efficient collection and analysis of “occurrences” and the clinical data associated with these kinds of patient events is described. The system is evaluated according to certain computer design criteria, and the system's implementation is assessed.
Wong, Adrian; Fong, Ching-Hang; Mok, Vincent Chung-Tong; Leung, Kam-Tat; Tong, Raymond Kai-Yu
2017-01-01
Computerized cognitive tests may serve as a preliminary, low-cost method to identify individuals with suspected cognitive impairment in the community. To develop a self-administered computerized test, namely the "Computerized Cognitive Screen (CoCoSc), Hong Kong version", for screening of individuals with cognitive impairment (CI) in community settings. The CoCoSc is a 15-min computerized cognitive screen covering memory, executive functions, orientation, attention and working memory, and prospective memory administered on a touchscreen computer. Individuals with CI and cognitively normal controls were administered the CoCoSc and the Montreal Cognitive Assessment (MoCA). Validity of the CoCoSc was assessed based on the relationship with the MoCA using Pearson correlation. Receiver operating characteristic curve (ROC) was used to examine the ability of the CoCoSc to differentiate CI from controls. Fifty-nine individuals with CI and 101 controls were recruited. Seventy-five (46.9%) participants had ≤6 years of education. Performance on the CoCoSc differed between normal and CI groups in both low and high education subgroups. Total scores of the CoCoSc and MoCA were significantly correlated (r = 0.71, p < 0.001). The area under ROC was 0.78, p < 0.001 for the CoCoSc total score in differentiating the CI group from the cognitively normal group. A cut-off of ≤30 on the CoCoSc was associated with a sensitivity of 0.78 and specificity of 0.69. The CoCoSc was well accepted by attendees of community social centers. The CoCoSc is a promising computerized cognitive screen for self-administration in community social centers. It is feasible for testing individuals with high or low education levels.
Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.
Staszewska, Anna; Zaki, Pearl; Lee, Joon
2017-10-06
Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious illness. ©Anna Staszewska, Pearl Zaki, Joon Lee. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 06.10.2017.
Chaple, Michael; Sacks, Stanley; McKendrick, Karen; Marsch, Lisa A; Belenko, Steven; Leukefeld, Carl; Prendergast, Michael; French, Michael
2014-01-01
Despite evidence that treatment is effective in reducing recidivism among inmates with substance use problems, scarce resources mean that few of those in need of treatment actually receive it. Computerized substance abuse interventions could be used to expand access to treatment in prisons without placing an undue burden on resources. The major aim of the study was to compare treatment conditions in terms of their service utilization, skills acquisition, and treatment satisfaction. The study recruited men and women with substance use disorders from 10 prisons in 4 states. In an open label clinical trial, 494 subjects were randomly assigned either to the Experimental condition, a computerized drug treatment intervention, the Therapeutic Education System (TES; n = 249), or to the Control condition, Standard Care ( n = 245). Chi-square tests compared groups on categorical variables and independent samples t tests were used for interval level continuous variables. Initial evidence demonstrated: (1) comparable group rates of session attendance and high rates of TES module completion for experimental subjects; (2) comparable group gains in the development of coping skills; and (3) a more favorable view of TES than of Standard Care . Collectively, these results show that a computerized intervention, such as TES, can be implemented successfully in prison. Given the barriers to the delivery of substance abuse treatment typically encountered in correctional settings, computerized interventions have the potential to fill a significant treatment gap and are particularly well suited to inmates with mild to moderate substance use disorders who often are not treated.
Computerized Observation System (COS) for Field Experiences.
ERIC Educational Resources Information Center
Reed, Thomas M.; And Others
The Computerized Observation System (COS) is a software program which an observer can use with a portable microcomputer to document preservice and inservice teacher performance. Specific observable behavior such as appropriate questions and responses shown to increase student achievement are recorded as Low Inference Observation Measures. Time on…
Lezin, B; Thouin, A; Besnehard, J; Lobbedez, T; Ollivier, C; Ryckelynck, J P
1999-08-01
Even though computerized workstations bring undisputed benefits in nursing units, introducing them is still hard when most of the staff members have to share the workstation. We took advantage of the implementation of the drug prescription software SAUPHIX in a nephrology department to better define the encountered difficulties. The workstation described in this paper is shared by physicians who enter their prescriptions (proprietary names, doses, routes of administration), nurses who use dosage schedules for drug administration, and the chemist who has authority to control prescription orders. Six months after the implementation of the workstation, physicians and nurses had to fill out an anonymous questionnaire aimed at assessing each function of the software. Prescriptions proved to be more accurate and legible, while management of drugs was more precise. However, interns complained that entering data was time consuming. Furthermore, they raised objections to control of prescription orders. Nurses criticized dosage schedules, the primary reason being that they had to change their practice. The convenience of notebooks was questioned by both physicians and nurses who would have preferred a greater number of desktop computers at their disposition. The implementation of a computerized workstation requires information, diplomacy and negotiations to obtain real implication of the staff. Tasks and schedules must be specified for everybody. The system has to be carefully customized, according to the requirement of the unit. Computers must be properly chosen and allocated in sufficient number. Finally, appropriate preparation, staff training and follow-up of the computerized system are essential.
The New Film Technologies: Computerized Video-Assisted Film Production.
ERIC Educational Resources Information Center
Mott, Donald R.
Over the past few years, video technology has been used to assist film directors after they have shot a scene, to control costs, and to create special effects, especially computer assisted graphics. At present, a computer based editing system called "Film 5" combines computer technology and video tape with film to save as much as 50% of…
1980-10-01
industrialized nations in almost every manufacturing market place. Many foreign nation’s manu- facturing advancements have resulted from...towards planning a computerized data storage and retrieval system based on Group Technology (GT) principles . The data storage and re- trieval...several computer languages available on the market to program numerically controlled machine tools. However, there was a need for a docu- ment showing
Computerized preparation of a scientific poster.
Lugo, M; Speaker, M G; Cohen, E J
1989-01-01
We prepared an attractive and effective poster using a Macintosh computer and Laserwriter and Imagewriter II printers. The advantages of preparing the poster in this fashion were increased control of the final product, decreased cost, and a sense of artistic satisfaction. Although we employed only the above mentioned computer, the desktop publishing techniques described can be used with other systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... IV-D Systems and Office Automation? 310.15 Section 310.15 Public Welfare Regulations Relating to... AND OFFICE AUTOMATION Requirements for Computerized Tribal IV-D Systems and Office Automation § 310.15... ensure the security and privacy of Computerized Tribal IV-D Systems and Office Automation? (a...
ERIC Educational Resources Information Center
Bornstein, Harry; Casella, Vicki
This interim report describes the development of a networked computerized classroom language management and recording system to assist teachers of children who are deaf or hard-of-hearing. The system will provide storage and access capability for such information as changes in instruction, language learning progress, modifications in communication…
The Design and Development of a Computerized Attention-Training Game System for School-Aged Children
ERIC Educational Resources Information Center
Wang, Tsui-Ying; Huang, Ho-Chuan
2013-01-01
A computerized attention-training game system has been developed to support attention training for school-aged children. The present system offers various types of computer games that provide training in different aspects of attention, such as selective attention, sustained attention, and divided attention. The N-tier architecture of the Web-based…
ERIC Educational Resources Information Center
Tiedeman, David V.
The author asserts that financial support of guidance activities, the job of the counselor, and counselors themselves will all have to change if computerized guidance support systems are to come into widespread use. The potential costs, benefits, and operating economics are discussed. Needed educational reorganization is dealt with on several…
ERIC Educational Resources Information Center
Smith, Hubert Gene
The objectives of the study presented in the dissertation were to identify present and anticipated information requirements of the various departments within the Oklahoma State Department of Vocational and Technical Education, to design a computerized information system model utilizing an integrated systems concept to meet information…
Assessment of Minimal HE (with emphasis on computerized psychometric tests)
Kappus, Matthew R; Bajaj, Jasmohan S
2012-01-01
Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464
Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands
NASA Astrophysics Data System (ADS)
Harber, H.
1981-09-01
The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.
Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands
NASA Technical Reports Server (NTRS)
Harber, H.
1981-01-01
The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.
Computerized management information systems and organizational structures
NASA Technical Reports Server (NTRS)
Zannetos, Z. S.; Sertel, M. R.
1970-01-01
The computerized management of information systems and organizational structures is discussed. The subjects presented are: (1) critical factors favoring centralization and decentralization of organizations, (2) classification of organizations by relative structure, (3) attempts to measure change in organization structure, and (4) impact of information technology developments on organizational structure changes.
Guidelines for the Development of Computerized Student Information Systems.
ERIC Educational Resources Information Center
Armes, Nancy, Ed.; And Others
Designed to provide guidelines for the development of computerized student information systems, this report raises policy issues and questions to be resolved at the campus level and describes a variety of computer-generated reports and records that can assist in educational decision making and planning. Introductory material discusses the…
ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals
DOE R&D Accomplishments Database
Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.
1977-01-01
The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.
A Computerized Interactive Vocabulary Development System for Advanced Learners.
ERIC Educational Resources Information Center
Kukulska-Hulme, Agnes
1988-01-01
Argues that the process of recording newly encountered vocabulary items in a typical language learning situation can be improved through a computerized system of vocabulary storage based on database management software that improves the discovery and recording of meaning, subsequent retrieval of items for productive use, and memory retention.…
A framework for capturing clinical data sets from computerized sources.
McDonald, C J; Overhage, J M; Dexter, P; Takesue, B Y; Dwyer, D M
1997-10-15
The pressure to improve health care and provide better care at a lower cost has generated the need for efficient capture of clinical data. Many data sets are now being defined to analyze health care. Historically, review and research organizations have simply determined what data they wanted to collect, developed forms, and then gathered the information through chart review without regard to what is already available institutionally in computerized databases. Today, much electronic patient information is available in operational data systems (for example, laboratory systems, pharmacy systems, and surgical scheduling systems) and is accessible by agencies and organizations through standards for messages, codes, and encrypted electronic mail. Such agencies and organizations should define the elements of their data sets in terms of standardized operational data, and data producers should fully adopt these code and message standards. The Health Plan Employer Data and Information Set and the Council of State and Territorial Epidemiologists in collaboration with the Centers for Disease Control and Prevention and the Association of State and Territorial Public Health Laboratory Directors provide examples of how this can be done.
Computerized Ultrasonic Testing System (CUTS) for in-process thickness determination
NASA Technical Reports Server (NTRS)
Frankel, J.; Doxbeck, M.; Schroeder, S. C.; Abbate, A.
1994-01-01
A Computerized Ultrasonic Testing System (CUTS) was developed to measure, in real-time, the rate of deposition and thickness of chromium plated on the inside of thick steel tubes. The measurements are made from the outside of the tubes with the ultrasonic pulse-echo technique. The resolution of the system is 2.5 micron. (0.0001 in.) and the accuracy is better than 10 micron (0.0004 in.). The thickness is measured using six transducers mounted at different locations on the tube. In addition, two transducers are mounted on two reference standards, thereby allowing the system to be continuously calibrated. The tube temperature varies during the process, thus the input from eight thermocouples, located at the measurement sites, is used to calculate and compensate for the change in return time of the ultrasonic echo due to the temperature dependence of the sound velocity. CUTS is applicable to any commercial process where real-time change of thickness of a sample has to be known, with the advantage of facilitating increased efficiency and of improving process control.
ERIC Educational Resources Information Center
Meijer, Rob R.; van Krimpen-Stoop, Edith M. L. A.
In this study a cumulative-sum (CUSUM) procedure from the theory of Statistical Process Control was modified and applied in the context of person-fit analysis in a computerized adaptive testing (CAT) environment. Six person-fit statistics were proposed using the CUSUM procedure, and three of them could be used to investigate the CAT in online test…
Minimizing drug misuse among elders: a proposal.
Craig, J A; Eves, G B
1987-01-01
This proposal is aimed at reducing the risk of adverse drug interactions that may occur when over-the-counter (OTC) preparations are taken in conjunction with prescription drugs in an unsupervised regimen. Such polymedicating is practiced widely among the elderly. A pilot program would be implemented over 12 months at three drugstores of a major retail chain. A barcode-based computer system would be used to identify potential adverse drug interactions for elderly customers. All volunteers admitted to the study, controls and subjects, would agree to buy all their medications, prescriptions and OTC, at the participating pharmacies. In return, the volunteers would receive discounts of 25 percent on prescription and OTC drugs and 10 percent on vitamins. Study subjects (N = 375) would carry barcoded identification (BID) cards that would activate the computerized program to assess each purchase for compatibility with their other medications; controls (N = 375) would carry "dummy" BID cards that would prompt the computer to approve all drug purchases. A final comparison of the subjects with the controls, as well as with a sample of elderly residents selected randomly from the community, would determine whether such a computerized, commercially based drug use review system could reduce the potential for adverse interactions between OTC and prescription drugs among the elderly. PMID:3101129
ERIC Educational Resources Information Center
Balottin, Umberto; And Others
1989-01-01
The study of computerized tomography brain-scan findings with 45 autistic and 19 control subjects concluded that autism is nonspecifically associated with brain-scan abnormalities, and that other nonorganic, as well as organic, factors should be taken into account. (Author/DB)
Computerized physician order entry from a chief information officer perspective.
Cotter, Carole M
2004-12-01
Designing and implementing a computerized physician order entry system in the critical care units of a large urban hospital system is an enormous undertaking. With their significant potential to improve health care and significantly reduce errors, the time for computerized physician order entry or physician order management systems is past due. Careful integrated planning is the key to success, requiring multidisciplinary teams at all levels of clinical and administrative management to work together. Articulated from the viewpoint of the Chief Information Officer of Lifespan, a not-for-profit hospital system in Rhode Island, the vision and strategy preceding the information technology plan, understanding the system's current state, the gap analysis between current and future state, and finally, building and implementing the information technology plan are described.
Computerized Biomechanical Man-Model
1976-07-01
Force Systems Command Wright-Patterson AFB, Ohio ABSTRACT The COMputerized BIomechanical MAN-Model (called COMBIMAN) is a computer interactive graphics...concept was to build a mock- The use of mock-ups for biomechanical evalua- up which permitted the designer to visualize the tion has long been a tool...of the can become an obstacle to design change. Aerospace Medical Research Laboratory, we are developing a computerized biomechanical man-model
A computerized tree growth projection system for forest resource evaluation in the lake states
Allen L. Lundgren; Burton L. Essex
1978-01-01
A computerized tree growth projection system has been developed for the Lake States Region as part of a larger Forest Resources Evaluation Program (FREP). Incorporating data from more than 1500 permanent growth plots throughout the Lake States, this system projects tree growth, mortality, regeneration, and removals in stands with any mixture of tree species and sizes,...
ERIC Educational Resources Information Center
Pintao, Carlos A. F.; de Souza Filho, Moacir P.
2007-01-01
This paper proposes a different experimental setup compared with the traditional ones, in order to determine the acceleration of gravity, which is carried out by using a fluid at a constant rotation. A computerized rotational system--by using a data acquisition system with specific software, a power amplifier and a rotary motion sensor--is…
ERIC Educational Resources Information Center
Arutunian, Carol Ann
The Computerized Vocational Information System (CVIS) at Willowbrook High School in Villa Park, Illinois, uses the computer as a tool to help each student explore a wide range of occupations and educational opportunities with some feedback from his own record of ability, achievement, and interest. Computer-based guidance systems are considered a…
The Structural Ceramics Database: Technical Foundations
Munro, R. G.; Hwang, F. Y.; Hubbard, C. R.
1989-01-01
The development of a computerized database on advanced structural ceramics can play a critical role in fostering the widespread use of ceramics in industry and in advanced technologies. A computerized database may be the most effective means of accelerating technology development by enabling new materials to be incorporated into designs far more rapidly than would have been possible with traditional information transfer processes. Faster, more efficient access to critical data is the basis for creating this technological advantage. Further, a computerized database provides the means for a more consistent treatment of data, greater quality control and product reliability, and improved continuity of research and development programs. A preliminary system has been completed as phase one of an ongoing program to establish the Structural Ceramics Database system. The system is designed to be used on personal computers. Developed in a modular design, the preliminary system is focused on the thermal properties of monolithic ceramics. The initial modules consist of materials specification, thermal expansion, thermal conductivity, thermal diffusivity, specific heat, thermal shock resistance, and a bibliography of data references. Query and output programs also have been developed for use with these modules. The latter program elements, along with the database modules, will be subjected to several stages of testing and refinement in the second phase of this effort. The goal of the refinement process will be the establishment of this system as a user-friendly prototype. Three primary considerations provide the guidelines to the system’s development: (1) The user’s needs; (2) The nature of materials properties; and (3) The requirements of the programming language. The present report discusses the manner and rationale by which each of these considerations leads to specific features in the design of the system. PMID:28053397
Kurth, Ann E; Spielberg, Freya; Cleland, Charles M; Lambdin, Barrot; Bangsberg, David R; Frick, Pamela A; Severynen, Anneleen O; Clausen, Marc; Norman, Robert G; Lockhart, David; Simoni, Jane M; Holmes, King K
2014-04-15
Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Longitudinal randomized controlled trial. An academic HIV clinic and a community-based organization in Seattle. In a total of 240 HIV-positive adults on ART, 209 completed 9-month follow-up (87% retention). Randomization to computerized counseling or assessment only, 4 sessions over 9 months. HIV-1 viral suppression, and self-reported ART adherence and transmission risks, compared using generalized estimating equations. Overall, intervention participants had reduced viral load: mean 0.17 log10 decline, versus 0.13 increase in controls, P = 0.053, and significant difference in ART adherence baseline to 9 months (P = 0.046). Their sexual transmission risk behaviors decreased (odds ratio = 0.55, P = 0.020), a reduction not seen among controls (odds ratio = 1.1, P = 0.664), and a significant difference in change (P = 0.040). Intervention effect was driven by those most in need; among those with detectable virus at baseline (>30 copies/mL, n = 89), intervention effect was mean 0.60 log10 viral load decline versus 0.15 increase in controls, P = 0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, P = 0.038. Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior.
NASA Technical Reports Server (NTRS)
Scaffidi, C. A.; Stocklin, F. J.; Feldman, M. B.
1971-01-01
An L-band telemetry system designed to provide the capability of near-real-time processing of calibration data is described. The system also provides the capability of performing computerized spacecraft simulations, with the aircraft as a data source, and evaluating the network response. The salient characteristics of a telemetry analysis and simulation program (TASP) are discussed, together with the results of TASP testing. The results of the L-band system testing have successfully demonstrated the capability of near-real-time processing of telemetry test data, the control of the ground-received signal to within + or - 0.5 db, and the computer generation of test signals.
Computer system for scanning tunneling microscope automation
NASA Astrophysics Data System (ADS)
Aguilar, M.; García, A.; Pascual, P. J.; Presa, J.; Santisteban, A.
1987-03-01
A computerized system for the automation of a scanning tunneling microscope is presented. It is based on an IBM personal computer (PC) either an XT or an AT, which performs the control, data acquisition and storage operations, displays the STM "images" in real time, and provides image processing tools for the restoration and analysis of data. It supports different data acquisition and control cards and image display cards. The software has been designed in a modular way to allow the replacement of these cards and other equipment improvements as well as the inclusion of user routines for data analysis.
Stereo optical guidance system for control of industrial robots
NASA Technical Reports Server (NTRS)
Powell, Bradley W. (Inventor); Rodgers, Mike H. (Inventor)
1992-01-01
A device for the generation of basic electrical signals which are supplied to a computerized processing complex for the operation of industrial robots. The system includes a stereo mirror arrangement for the projection of views from opposite sides of a visible indicia formed on a workpiece. The views are projected onto independent halves of the retina of a single camera. The camera retina is of the CCD (charge-coupled-device) type and is therefore capable of providing signals in response to the image projected thereupon. These signals are then processed for control of industrial robots or similar devices.
A multilevel control system for the large space telescope. [numerical analysis/optimal control
NASA Technical Reports Server (NTRS)
Siljak, D. D.; Sundareshan, S. K.; Vukcevic, M. B.
1975-01-01
A multilevel scheme was proposed for control of Large Space Telescope (LST) modeled by a three-axis-six-order nonlinear equation. Local controllers were used on the subsystem level to stabilize motions corresponding to the three axes. Global controllers were applied to reduce (and sometimes nullify) the interactions among the subsystems. A multilevel optimization method was developed whereby local quadratic optimizations were performed on the subsystem level, and global control was again used to reduce (nullify) the effect of interactions. The multilevel stabilization and optimization methods are presented as general tools for design and then used in the design of the LST Control System. The methods are entirely computerized, so that they can accommodate higher order LST models with both conceptual and numerical advantages over standard straightforward design techniques.
Improving Security for SCADA Sensor Networks with Reputation Systems and Self-Organizing Maps.
Moya, José M; Araujo, Alvaro; Banković, Zorana; de Goyeneche, Juan-Mariano; Vallejo, Juan Carlos; Malagón, Pedro; Villanueva, Daniel; Fraga, David; Romero, Elena; Blesa, Javier
2009-01-01
The reliable operation of modern infrastructures depends on computerized systems and Supervisory Control and Data Acquisition (SCADA) systems, which are also based on the data obtained from sensor networks. The inherent limitations of the sensor devices make them extremely vulnerable to cyberwarfare/cyberterrorism attacks. In this paper, we propose a reputation system enhanced with distributed agents, based on unsupervised learning algorithms (self-organizing maps), in order to achieve fault tolerance and enhanced resistance to previously unknown attacks. This approach has been extensively simulated and compared with previous proposals.
Improving Security for SCADA Sensor Networks with Reputation Systems and Self-Organizing Maps
Moya, José M.; Araujo, Álvaro; Banković, Zorana; de Goyeneche, Juan-Mariano; Vallejo, Juan Carlos; Malagón, Pedro; Villanueva, Daniel; Fraga, David; Romero, Elena; Blesa, Javier
2009-01-01
The reliable operation of modern infrastructures depends on computerized systems and Supervisory Control and Data Acquisition (SCADA) systems, which are also based on the data obtained from sensor networks. The inherent limitations of the sensor devices make them extremely vulnerable to cyberwarfare/cyberterrorism attacks. In this paper, we propose a reputation system enhanced with distributed agents, based on unsupervised learning algorithms (self-organizing maps), in order to achieve fault tolerance and enhanced resistance to previously unknown attacks. This approach has been extensively simulated and compared with previous proposals. PMID:22291569
Computerized Information Management in Long-Term Care: A Case Study. Technical Report No. 303.
ERIC Educational Resources Information Center
Zawadski, Rick T.; Gee, Stephen
This technical report describes the computerized information management system used at the Community Care Organization for Dependent Adults (CCODA) of the On Lok Senior Health Services in San Francisco's Chinatown (California). A background perspective on information systems in business, government, hospitals, and local community service agencies…
ERIC Educational Resources Information Center
Buckley, Joseph J.
This report first analyzes the need for a Technical Assistance Center (TAC) Clearinghouse, which would provide a range of services including question answering for state and local education agencies, workshop preparation assistance, and literature surveys. Addressing the question of feasibility of a computerized information retrieval system for…
ERIC Educational Resources Information Center
Wong, S. Godwin
This report describes the APL (Accountable unit, Program, and line item) budget system, a computerized three-dimensional program budget system that has been implemented in the Cambridge (Massachusetts) School Department. Various chapters discuss the differences between traditional budgeting and program budgeting, present an overview of te APL…
ERIC Educational Resources Information Center
Kinnaman, Joanna E. Strong; Farrell, Albert D.; Bisconer, Sarah W.
2006-01-01
Assessment procedures to evaluate inpatient treatment effectiveness can provide information to inform clinical practice. The Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) represents a standardized approach to assess patients' target problems that combines elements of individualized and nomothetic approaches.…
An Analysis of Community Health Nurses Documentation: The Best Approach to Computerization
Chalmers, M.
1988-01-01
The study explored and analyzed the actual patient-related documentation performed by a sample of community health nurses working in voluntary home health agencies. The outcome of the study was a system flow chart of that documentation and included: common components of the documentation, where in the existing systems they are recorded, when they are recorded by the nurse and why they are used by the nurses and administrative personnel in the agencies. The flow chart is suitable for use as a prototype for the development of a computer software package for the computerization of the patient-related documentation by community health nurses. General System and communication theories were used as a framework for this study. A thorough analysis of the documenation resulted in a complete and exhaustive explication of the documentation by community health nurses, as well as the identification of what parts of that documentation lend themselves most readily to computerization and what areas, if any, may not readily adapt to computerization.
Computerized tomography calibrator
NASA Technical Reports Server (NTRS)
Engel, Herbert P. (Inventor)
1991-01-01
A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.
Anti-Mechanized Defense: A Computerized Simulation for Squad Leader Training.
1983-09-01
applicability of cybernetic principles is easily transformed to meet the needs of this research. Specifi- cally, the basic principle governing management...and as in other areas this is better meas- ured in actual field conditions. COMMAND AND CONTROL (S2A.2) Control of Organic Fi repower In general...AD-AI34 962 UNCLASSIFIED ANTI-MECHANIZED DEFENSE: A COMPUTERIZED SQUAD LEADER TRAINING(U) AIR FORCE INST WRIGHT-PATTERSON AFB OH SCHOOL OF SYST
Design of a solar array simulator for the NASA EOS testbed
NASA Technical Reports Server (NTRS)
Butler, Steve J.; Sable, Dan M.; Lee, Fred C.; Cho, Bo H.
1992-01-01
The present spacecraft solar array simulator addresses both dc and ac characteristics as well as changes in illumination and temperature and performance degradation over the course of array service life. The computerized control system used allows simulation of a complete orbit cycle, in addition to automated diagnostics. The simulator is currently interfaced with the NASA EOS testbed.
Sawmill simulation and the best opening face system : a user`s guide
D. W. Lewis
1985-01-01
Computer sawmill simulation models are being used to increase lumber yield and improve management control. Although there are few managers or technical people in the sawmill industry who are not aware of the existence of these models, many do not realize the modelsa full potential. The first section of this paper describes computerized sawmill simulation models and...
ERIC Educational Resources Information Center
Sandler, Mark
1985-01-01
Discusses several concerns about nature of online public access catalogs (OPAC) that have particular import to reference librarians: user passivity and loss of control growing out of "human-machine interface" and the larger social context; and the tendency of computerized bibliographic systems to obfuscate human origins of library…
A computerized faculty time-management system in an academic family medicine department.
Daugird, Allen J; Arndt, Jane E; Olson, P Richard
2003-02-01
The authors describe the development, implementation, and evaluation of a computerized faculty time-management system (FTMS) in the Department of Family Medicine at the University of North Carolina-Chapel Hill. The FTMS is presented as an integrated set of computerized spreadsheets used annually to allocate faculty time across all mission activities of the department. It was first implemented in 1996 and has been continuously developed since then. An iterative approach has been used to gain consensus among faculty about time resources needed for various tasks of all missions of the department. These time-resource assumptions are used in the computerized system. Faculty time is allocated annually by the department vice chair in negotiation with individual faculty, making sure that the activities planned do not exceed the work time each faculty member has available for the year. During this process, faculty preferences are balanced against department aggregate needs to meet mission commitments and obligations. The authors describe how the computerized FTMS is used for faculty time management and career development, department planning, budget planning, clinical scheduling, and mission cost accounting. They also describe barriers and potential abuses and the challenge of building an organizational culture willing to discuss faculty time openly and committed to developing a system perceived as fair and accurate. The spreadsheet file is available free from the authors for use in other departments.
Collaboration Scripts for Enhancing Metacognitive Self-Regulation and Mathematics Literacy
ERIC Educational Resources Information Center
Chen, Cheng-Huan; Chiu, Chiung-Hui
2016-01-01
This study designed a set of computerized collaboration scripts for multi-touch supported collaborative design-based learning and evaluated its effects on multiple aspects of metacognitive self-regulation in terms of planning and controlling and mathematical literacy achievement at higher and lower levels. The computerized scripts provided a…
Process computerization of No. 13 blast furnace at Gary works
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, G.J.; Zmierski, M.L.; Hyle, F.W.
1993-10-01
No. 13 blast furnace underwent extensive modifications to the process control system during the second reline. This represents a major shift in control philosophy from hardwired relays and analog controllers to a totally integrated computer control system. The new system created the opportunity for comprehensive diagnostic analysis and increased flexibility for control strategy modifications. The goal of achieving maximum production with minimal delay was accomplished by an integrated test, and comprehensive operator and maintenance training. Normal production was reached within four days of blow-ink and design production capacity of 7800 NTHM/day was met in the third month of operation. Recordmore » furnace productivity of 8931 NTHM/day (8.56 NTHM/100 crwv) was achieved in less than five months of operation and again in April 1992 of 9062 NTHM/day (8.68 NTHM/100 cfwv).« less
Computerized Adaptive Testing System Design: Preliminary Design Considerations.
1982-07-01
the administrative or operational requirements of CAT and presented - # k*----.,ku nh-n.-utu (IPOI efi~g.2me (PMU tQ7q. vim NPRDC TR 82-52 July 1982...design model for a computerized adaptive testing ( CAT ) system was developed and presented through a series of hierarchy plus input-process-output (HIPO...physical system was addressed through brief discussions of hardware, software, interfaces, and personnel requirements. Further steps in CAT system
Chen, Jeannie; Shabot, M. Michael; LoBue, Mark
2003-01-01
Prior attempts to interface ICU Clinical Information Systems (CIS) to Pharmacy systems have been less than successful. The major problem is that in ICUs, medications frequently have to be administered and charted in the CIS Medication Administration Record (MAR) before pharmacists can enter them into the Pharmacy system. When the Pharmacy system belatedly sends medication orders to the CIS MAR, this may create duplicate entries for medications that ICU nurses have had to enter manually to chart doses actually given. The authors have implemented a real time interface between a Computerized Physician Order Entry (CPOE) system and a CIS operating in ten ICUs that solves this problem. The interface transfers new medication orders including order details and alerts directly to the CIS Medication Administration Record (MAR), where they are immediately available for nurse charting. PMID:14728315
NASA Technical Reports Server (NTRS)
Mardirossian, H.; Beri, A. C.; Doll, C. E.
1990-01-01
The Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC) provides spacecraft trajectory determination for a wide variety of National Aeronautics and Space Administration (NASA)-supported satellite missions, using the Tracking Data Relay Satellite System (TDRSS) and Ground Spaceflight and Tracking Data Network (GSTDN). To take advantage of computerized decision making processes that can be used in spacecraft navigation, the Orbit Determination Automation System (ODAS) was designed, developed, and implemented as a prototype system to automate orbit determination (OD) and orbit quality assurance (QA) functions performed by orbit operations. Based on a machine-resident generic schedule and predetermined mission-dependent QA criteria, ODAS autonomously activates an interface with the existing trajectory determination system using a batch least-squares differential correction algorithm to perform the basic OD functions. The computational parameters determined during the OD are processed to make computerized decisions regarding QA, and a controlled recovery process is activated when the criteria are not satisfied. The complete cycle is autonomous and continuous. ODAS was extensively tested for performance under conditions resembling actual operational conditions and found to be effective and reliable for extended autonomous OD. Details of the system structure and function are discussed, and test results are presented.
NASA Technical Reports Server (NTRS)
Mardirossian, H.; Heuerman, K.; Beri, A.; Samii, M. V.; Doll, C. E.
1989-01-01
The Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC) provides spacecraft trajectory determination for a wide variety of National Aeronautics and Space Administration (NASA)-supported satellite missions, using the Tracking Data Relay Satellite System (TDRSS) and Ground Spaceflight and Tracking Data Network (GSTDN). To take advantage of computerized decision making processes that can be used in spacecraft navigation, the Orbit Determination Automation System (ODAS) was designed, developed, and implemented as a prototype system to automate orbit determination (OD) and orbit quality assurance (QA) functions performed by orbit operations. Based on a machine-resident generic schedule and predetermined mission-dependent QA criteria, ODAS autonomously activates an interface with the existing trajectory determination system using a batch least-squares differential correction algorithm to perform the basic OD functions. The computational parameters determined during the OD are processed to make computerized decisions regarding QA, and a controlled recovery process isactivated when the criteria are not satisfied. The complete cycle is autonomous and continuous. ODAS was extensively tested for performance under conditions resembling actual operational conditions and found to be effective and reliable for extended autonomous OD. Details of the system structure and function are discussed, and test results are presented.
Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto
2014-01-01
To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, p<0.001); satisfaction decreased with age (p<0.001). Physicians scored lower concerning the potential of the computerized physician order entry for improving patient safety (5.45±2.20 versus 8.09±2.21, p<0.001) and the ease of using the computerized physician order entry (3.83±1.88 versus 6.44±2.31, p<0.001). The characteristics independently associated with satisfaction were the system's user-friendliness, accuracy, capacity to provide clear information, and fast response time. Six months after its implementation, healthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.
Moja, Lorenzo; Passardi, Alessandro; Capobussi, Matteo; Banzi, Rita; Ruggiero, Francesca; Kwag, Koren; Liberati, Elisa Giulia; Mangia, Massimo; Kunnamo, Ilkka; Cinquini, Michela; Vespignani, Roberto; Colamartini, Americo; Di Iorio, Valentina; Massa, Ilaria; González-Lorenzo, Marien; Bertizzolo, Lorenzo; Nyberg, Peter; Grimshaw, Jeremy; Bonovas, Stefanos; Nanni, Oriana
2016-11-25
Computerized decision support systems (CDSSs) are computer programs that provide doctors with person-specific, actionable recommendations, or management options that are intelligently filtered or presented at appropriate times to enhance health care. CDSSs might be integrated with patient electronic health records (EHRs) and evidence-based knowledge. The Computerized DEcision Support in ONCOlogy (ONCO-CODES) trial is a pragmatic, parallel group, randomized controlled study with 1:1 allocation ratio. The trial is designed to evaluate the effectiveness on clinical practice and quality of care of a multi-specialty collection of patient-specific reminders generated by a CDSS in the IRCCS Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) hospital. We hypothesize that the intervention can increase clinician adherence to guidelines and, eventually, improve the quality of care offered to cancer patients. The primary outcome is the rate at which the issues reported by the reminders are resolved, aggregating specialty and primary care reminders. We will include all the patients admitted to hospital services. All analyses will follow the intention-to-treat principle. The results of our study will contribute to the current understanding of the effectiveness of CDSSs in cancer hospitals, thereby informing healthcare policy about the potential role of CDSS use. Furthermore, the study will inform whether CDSS may facilitate the integration of primary care in cancer settings, known to be usually limited. The increasing use of and familiarity with advanced technology among new generations of physicians may support integrated approaches to be tested in pragmatic studies determining the optimal interface between primary and oncology care. ClinicalTrials.gov, NCT02645357.
Computerized analysis of fetal heart rate variability signal during the stages of labor.
Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta
2016-03-01
To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (< 0.05). Statistically significant differences were seen between baseline FHR, MF and HF (P < 0.001), in which the first two were reduced and the third was increased when compared between pre-labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.
Automated Electrostatics Environmental Chamber
NASA Technical Reports Server (NTRS)
Calle, Carlos; Lewis, Dean C.; Buchanan, Randy K.; Buchanan, Aubri
2005-01-01
The Mars Electrostatics Chamber (MEC) is an environmental chamber designed primarily to create atmospheric conditions like those at the surface of Mars to support experiments on electrostatic effects in the Martian environment. The chamber is equipped with a vacuum system, a cryogenic cooling system, an atmospheric-gas replenishing and analysis system, and a computerized control system that can be programmed by the user and that provides both automation and options for manual control. The control system can be set to maintain steady Mars-like conditions or to impose temperature and pressure variations of a Mars diurnal cycle at any given season and latitude. In addition, the MEC can be used in other areas of research because it can create steady or varying atmospheric conditions anywhere within the wide temperature, pressure, and composition ranges between the extremes of Mars-like and Earth-like conditions.
The Effect of Computerized System Feedback Availability during Executive Function Training
ERIC Educational Resources Information Center
Yuviler-Gavish, Nirit; Krisher, Hagit
2016-01-01
Computerized training systems offer a promising new direction in the training of executive functions, in part because they can easily be designed to offer feedback to learners. Yet, feedback is a double-edged sword, serving a positive motivational role while at the same time carrying the risk that learners may become dependent on the feedback they…
ERIC Educational Resources Information Center
Hopf-Weichel, Rosemarie; And Others
This report describes results of the first year of a three-year program to develop and evaluate a new Adaptive Computerized Training System (ACTS) for electronics maintenance training. (ACTS incorporates an adaptive computer program that learns the student's diagnostic and decision value structure, compares it to that of an expert, and adapts the…
Wilderness Management... A Computerized System for Summarizing Permit Information
Gary H. Elsner
1972-01-01
Permits were first needed for visits to wilderness areas in California during summer 1971. A computerized system for analyzing these permits and summarizing information from them has been developed. It produces four types of summary tables: point-of-origin of visitors; daily variation in total number of persons present; variations in group size; and variations in...
45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?
Code of Federal Regulations, 2014 CFR
2014-10-01
... acquisitions of Computerized Tribal IV-D Systems? (a) APD Approval. A comprehensive Tribal IV-D agency must... include a clause that provides that the comprehensive Tribal IV-D agency will have all ownership rights to... use and to authorize others to use for Federal Government purposes, such software, modifications and...
45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?
Code of Federal Regulations, 2011 CFR
2011-10-01
... acquisitions of Computerized Tribal IV-D Systems? (a) APD Approval. A comprehensive Tribal IV-D agency must... include a clause that provides that the comprehensive Tribal IV-D agency will have all ownership rights to... use and to authorize others to use for Federal Government purposes, such software, modifications and...
45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?
Code of Federal Regulations, 2013 CFR
2013-10-01
... acquisitions of Computerized Tribal IV-D Systems? (a) APD Approval. A comprehensive Tribal IV-D agency must... include a clause that provides that the comprehensive Tribal IV-D agency will have all ownership rights to... use and to authorize others to use for Federal Government purposes, such software, modifications and...
The Computerized Educational Guidance System. EDGUYD Manual.
ERIC Educational Resources Information Center
Cassel, Russell N.
The Computerized Educational Guidance System (EDGUYD) permits one to narrow post high school educational planning where consideration is given to all 1,448 4-year colleges and universities in the United States. This, to be sure, is a feat no human counselor is capable of without a computer. The Educational Success Index (ESI) is the means used by…
Validation of a Computerized Cognitive Assessment System for Persons with Stroke: A Pilot Study
ERIC Educational Resources Information Center
Yip, Chi Kwong; Man, David W. K.
2009-01-01
This study investigates the validity of a newly developed computerized cognitive assessment system (CCAS) that is equipped with rich multimedia to generate simulated testing situations and considers both test item difficulty and the test taker's ability. It is also hypothesized that better predictive validity of the CCAS in self-care of persons…
ERIC Educational Resources Information Center
Hsu, Chien-Ju; Thompson, Cynthia K.
2018-01-01
Purpose: The purpose of this study is to compare the outcomes of the manually coded Northwestern Narrative Language Analysis (NNLA) system, which was developed for characterizing agrammatic production patterns, and the automated Computerized Language Analysis (CLAN) system, which has recently been adopted to analyze speech samples of individuals…
ERIC Educational Resources Information Center
Kunisch, Joseph Martin
2012-01-01
Background: The Emergency Severity Index (ESI) is an emergency department (ED) triage classification system based on estimated patient-specific resource utilization. Rules for a computerized clinical decision support (CDS) system based on a patient's chief complaint were developed and tested using a stochastic model for predicting ESI scores.…
Computerized Posturographic Measurement in Elderly Women with Unilateral Knee Osteoarthritis
Lim, Kil-Byung
2012-01-01
Objective To identify the subtle change of postural control in elderly patients with unilateral knee osteoarthritis (OA) with computerized dynamic posturography. Method Twenty-two healthy women and twenty-six women with unilateral knee OA, aged 60 and over, were enrolled. The computerized posturographic measures included a weight bearing pattern during squatting and sit-to-stand, sway velocity of center of gravity (COG) during one leg standing, on-axis velocity and directional control of COG during rhythmic weight shift, rising index during sit-to-stand, end sway during tandem walk, and movement time during step up/over. Results It was shown that patients bore significantly less weight on the affected side during the 30° and 60° squat and sit-to-stand. Sway velocity of COG during one leg standing was greater whereas the on-axis velocity and directional control during the front/back rhythmic weight shift were significantly lower in the patient group. The rising index during sit-to-stand was significantly lower and movement time during step up/over with the affected side was significantly longer in patients. Conclusion This study demonstrated in detail a decline of postural balance by utilizing computerized posturography in elderly women with unilateral knee OA. They had less weight-bearing, more sway, and less ability of intentional postural control on the affected side. PMID:23185725
NASA Astrophysics Data System (ADS)
Takahashi, Masakazu; Fukue, Yoshinori
This paper proposes a Retrospective Computerized System Validation (RCSV) method for Drug Manufacturing Software (DMSW) that relates to drug production considering software modification. Because DMSW that is used for quality management and facility control affects big impact to quality of drugs, regulatory agency required proofs of adequacy for DMSW's functions and performance based on developed documents and test results. Especially, the work that explains adequacy for previously developed DMSW based on existing documents and operational records is called RCSV. When modifying RCSV conducted DMSW, it was difficult to secure consistency between developed documents and test results for modified DMSW parts and existing documents and operational records for non-modified DMSW parts. This made conducting RCSV difficult. In this paper, we proposed (a) definition of documents architecture, (b) definition of descriptive items and levels in the documents, (c) management of design information using database, (d) exhaustive testing, and (e) integrated RCSV procedure. As a result, we could conduct adequate RCSV securing consistency.
Powerful nuclear technology, anywhere, requires functioning system of free elections
NASA Astrophysics Data System (ADS)
Synek, Miroslav
2000-03-01
Historical development on our planet, utilizing the knowledge of physics, has reached a powerful technology of nuclear intercontinental ballistic missiles, conceivably controllable through a computerized ``push-button". Whenever this technology falls under the control of an irresponsible, miscalculating, or, insane, dictator, with powerful means of a mass-produced nuclear built-up, anywhere on our planet, the very survival of all humanity on our planet could be threatened. Therefore, it is a historical urgency that this technology is under the control by a government of the people, by the people and for the people, based on a sufficiently secure system of free elections, in any country on our planet, wherever and whenever such a threatening possibility exists.
Microcomputer Network for Computerized Adaptive Testing (CAT): Program Listing. Supplement.
1984-03-01
UMICROCOMPUTER NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ): PROGRAM LISTING in APPROVED FOR PUBLIC RELEASE;IDISTRIBUTION UNLIMITEDPs DTIC ’ Akf 3 0 1-d84...NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ).- PROGRAM LISTING , ,j Baldwin Quan Thomas A. Park Gary Sandahl John H. Wolfe Reviewed by James R. McBride A...Center San Diego, California 92152 V.% :-, CONTENTrS Page CATPROJECT.TEXT CAT system driver textfile I 1 ADMINDIR- Subdirectory - Test administration
What can posturography tell us about vestibular function?
NASA Technical Reports Server (NTRS)
Black, F. O.
2001-01-01
Patients with balance disorders want answers to the following basic questions: (1) What is causing my problem? and (2) What can be done about my problem? Information to fully answer these questions must include status of both sensory and motor components of the balance control systems. Computerized dynamic posturography (CDP) provides quantitative assessment of both sensory and motor components of postural control along with how the sensory inputs to the brain interact. This paper reviews the scientific basis and clinical applications of CDP. Specifically, studies describing the integration of vestibular inputs with other sensory systems for postural control are briefly summarized. Clinical applications, including assessment, rehabilitation, and management are presented. Effects of aging on postural control along with prevention and management strategies are discussed.
Development and training of a learning expert system in an autonomous mobile robot via simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spelt, P.F.; Lyness, E.; DeSaussure, G.
1989-11-01
The Center for Engineering Systems Advanced Research (CESAR) conducts basic research in the area of intelligent machines. Recently at CESAR a learning expert system was created to operate on board an autonomous robot working at a process control panel. The authors discuss two-computer simulation system used to create, evaluate and train this learning system. The simulation system has a graphics display of the current status of the process being simulated, and the same program which does the simulating also drives the actual control panel. Simulation results were validated on the actual robot. The speed and safety values of using amore » computerized simulator to train a learning computer, and future uses of the simulation system, are discussed.« less
Industrial Control Systems/SCADA systems risk assessment in the energy sector
NASA Astrophysics Data System (ADS)
Falodun, Babatunde
The energy sector is one of the most critical components of our national infrastructure. It not only provides the electrical power and petroleum required to run day-to-day operations and mechanisms in society, it's also an important element that directly impacts the economy with regard to growth and stability. Industrial Control Systems (ICS) /Supervisory Control and Data Acquisition Systems (SCADA) are computerized mechanisms, they are both software and hardware that are used to control real time processes and operations in power plants and oil production facilities. A significant attack on these control systems that leads to widespread disruption of energy could result in catastrophic consequences for any major city and even the nation. This research paper explores cyber threats and vulnerabilities faced by ICS/SCADA systems in the energy sector and also highlights possible outcomes of a successful breach. Furthermore, the research underscores mitigation strategies that could be used to prevent and respond to an attack. Keywords: Cybersecurity, SCADA, Cyber Attacks, Threats, Vulnerabilities, Risk Assessment, Dr. Albert Orbinati.
An Efficiency Balanced Information Criterion for Item Selection in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Han, Kyung T.
2012-01-01
Successful administration of computerized adaptive testing (CAT) programs in educational settings requires that test security and item exposure control issues be taken seriously. Developing an item selection algorithm that strikes the right balance between test precision and level of item pool utilization is the key to successful implementation…
Computerized Multi-Media Instructional Television. COMIT. Proceedings of a Symposium.
ERIC Educational Resources Information Center
Andrews, Gordon C., Ed.; Knapper, Christopher K., Ed.
A joint research project in educational techniques, which was conducted by the University of Waterloo and the IBM Corporation, explored the use of color television with random-access videotape under computer control. At the end of the three-year project, papers were solicited from all COMIT (Computerized Multi-Media Instructional Television)…
A Framework for the Development of Computerized Adaptive Tests
ERIC Educational Resources Information Center
Thompson, Nathan A.; Weiss, David J.
2011-01-01
A substantial amount of research has been conducted over the past 40 years on technical aspects of computerized adaptive testing (CAT), such as item selection algorithms, item exposure controls, and termination criteria. However, there is little literature providing practical guidance on the development of a CAT. This paper seeks to collate some…
High data volume and transfer rate techniques used at NASA's image processing facility
NASA Technical Reports Server (NTRS)
Heffner, P.; Connell, E.; Mccaleb, F.
1978-01-01
Data storage and transfer operations at a new image processing facility are described. The equipment includes high density digital magnetic tape drives and specially designed controllers to provide an interface between the tape drives and computerized image processing systems. The controller performs the functions necessary to convert the continuous serial data stream from the tape drive to a word-parallel blocked data stream which then goes to the computer-based system. With regard to the tape packing density, 1.8 times 10 to the tenth data bits are stored on a reel of one-inch tape. System components and their operation are surveyed, and studies on advanced storage techniques are summarized.
Development of a character, line and point display system. [for medical records
NASA Technical Reports Server (NTRS)
Owen, E. W.
1977-01-01
A compact graphics terminal for use as the input to a computerized medical records system is described. The principal mode of communication between the terminal and the records system is by checklists and menu selection. However, the terminal accepts short, handwritten messages as well as conventional alphanumeric input. The terminal consists of an electronic tablet, a display, a microcomputer controller, a character generator, and a refresh memory for the display. An Intel SBC 80/10 microcomputer controls the flow of information and a 16 kilobyte memory stores the point-by-point array of information to be displayed. A specially designed interface continuously generates the raster display without the intervention of the microcomputer.
NASA/ASEE Summer Faculty Fellowship Program, 1990, Volume 1
NASA Technical Reports Server (NTRS)
Bannerot, Richard B. (Editor); Goldstein, Stanley H. (Editor)
1990-01-01
The 1990 Johnson Space Center (JSC) NASA/American Society for Engineering Education (ASEE) Summer Faculty Fellowship Program was conducted by the University of Houston-University Park and JSC. A compilation of the final reports on the research projects are presented. The topics covered include: the Space Station; the Space Shuttle; exobiology; cell biology; culture techniques; control systems design; laser induced fluorescence; spacecraft reliability analysis; reduced gravity; biotechnology; microgravity applications; regenerative life support systems; imaging techniques; cardiovascular system; physiological effects; extravehicular mobility units; mathematical models; bioreactors; computerized simulation; microgravity simulation; and dynamic structural analysis.
The Computerized Reference Department: Buying the Future.
ERIC Educational Resources Information Center
Kriz, Harry M.; Kok, Victoria T.
1985-01-01
Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…
A three-dimensional computerized isometric strength measurement system.
Black, Nancy L; Das, Biman
2007-05-01
The three-dimensional Computerized Isometric Strength Measurement System (CISMS) reliably and accurately measures isometric pull and push strengths in work spaces of paraplegic populations while anticipating comparative studies with other populations. The main elements of the system were: an extendable arm, a vertical supporting track, a rotating platform, a force transducer, stability sensors and a computerized data collection interface. The CISMS with minor modification was successfully used to measure isometric push-up and pull-down strengths of paraplegics and isometric push, pull, push-up and pull-down strength in work spaces for seated and standing able-bodied populations. The instrument has satisfied criteria of versatility, safety and comfort, ease of operation, and durability. Results are accurate within 2N for aligned forces. Costing approximately $1,500 (US) including computer, the system is affordable and accurate for aligned isometric strength measurements.
Integrating Images, Applications, and Communications Networks. Volume 5.
1987-12-01
AND ADDRESS 10. PROGRAM ELEMENT. PROJECT, TASK Massachusetts Institute of Technology AREA A WORK UNIT NUMBERS Cambridge, MA 02139 II. CONTROLLING...Systems Center (TSC) for their support and assistance, to Professor Joseph Sussman, Director, Center for Transportation Studies ( CTS ) at MIT for his...IEEE Press, New York, 1987. [15] W. J. Hawkins. Bits and Bytes. 0 Popular Science, January, 1984. [16] G. N. Hounsfield . Computerized Tranverse Axial
NASA Astrophysics Data System (ADS)
Collmann, Jeff R.
2003-05-01
This paper justifies and explains current efforts in the Military Health System (MHS) to enhance information assurance in light of the sociological debate between "Normal Accident" (NAT) and "High Reliability" (HRT) theorists. NAT argues that complex systems such as enterprise health information systems display multiple, interdependent interactions among diverse parts that potentially manifest unfamiliar, unplanned, or unexpected sequences that operators may not perceive or immediately understand, especially during emergencies. If the system functions rapidly with few breaks in time, space or process development, the effects of single failures ramify before operators understand or gain control of the incident thus producing catastrophic accidents. HRT counters that organizations with strong leadership support, continuous training, redundant safety features and "cultures of high reliability" contain the effects of component failures even in complex, tightly coupled systems. Building highly integrated, enterprise-wide computerized health information management systems risks creating the conditions for catastrophic breaches of data security as argued by NAT. The data security regulations of the Health Insurance Portability and Accountability Act of 1996 (HIPAA) implicitly depend on the premises of High Reliability Theorists. Limitations in HRT thus have implications for both safe program design and compliance efforts. MHS and other health care organizations should consider both NAT and HRT when designing and deploying enterprise-wide computerized health information systems.
Shulman, S; Shorer, R; Wollman, J; Dotan, G; Paran, D
2017-11-01
Background Cognitive impairment is frequent in systemic lupus erythematosus. Atrophy of the corpus callosum and hippocampus have been reported in patients with systemic lupus erythematosus, and diffusion tensor imaging studies have shown impaired white matter integrity, suggesting that white matter damage in systemic lupus erythematosus may underlie the cognitive impairment as well as other neuropsychiatric systemic lupus erythematosus manifestations. Retinal nerve fiber layer thickness, as assessed by optical coherence tomography, has been suggested as a biomarker for white matter damage in neurologic disorders such as multiple sclerosis, Alzheimer's disease and Parkinson's disease. Retinal nerve fiber layer thinning may occur early, even in patients with mild clinical symptoms. Aim The objective of this study was to assess the association of retinal nerve fiber layer thickness, as a biomarker of white matter damage in systemic lupus erythematosus patients, with neuropsychiatric systemic lupus erythematosus manifestations, including cognitive impairment. Methods Twenty-one consecutive patients with systemic lupus erythematosus underwent neuropsychological testing using a validated computerized battery of tests as well as the Rey-Auditory verbal learning test. All 21 patients, as well as 11 healthy, age matched controls, underwent optical coherence tomography testing to assess retinal nerve fiber layer thickness. Correlations between retinal nerve fiber layer thickness and results in eight cognitive domains assessed by the computerized battery of tests as well as the Rey-Auditory verbal learning test were assessed in patients with systemic lupus erythematosus, with and without neuropsychiatric systemic lupus erythematosus, and compared to retinal nerve fiber layer thickness in healthy controls. Results No statistically significant correlation was found between retinal nerve fiber layer thickness in patients with systemic lupus erythematosus as compared to healthy controls. When evaluating by subgroups, no correlation was found between patients with or without neuropsychiatric systemic lupus erythematosus or cognitive impairment and retinal nerve fiber layer thickness. Conclusion Retinal nerve fiber layer thickness of systemic lupus erythematosus patients was not found to be statistically different compared to controls. Within systemic lupus erythematosus patients there was no correlation between retinal nerve fiber layer thickness and cognitive impairment or other neuropsychiatric systemic lupus erythematosus manifestations.
Computerized proof techniques for undergraduates
NASA Astrophysics Data System (ADS)
Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu
2012-12-01
The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete mathematics. We demonstrate by examples how one can use these computerized proof techniques to raise students' interests in the discovery and proof of mathematical identities and enhance their problem-solving skills.
ERIC Educational Resources Information Center
Lutz, John E.; And Others
The degree of success of the computerized Child-Based Information System (CBIS) was analyzed in two areas--presenting, delivering, and managing a developmental curriculum; and recording, filing, and monitoring child tracking data, including requirements for Individualized Education Plans (IEP's). Preschool handicapped and high-risk children and…
Implementation of a Computerized Maintenance Management System
NASA Technical Reports Server (NTRS)
Shen, Yong-Hong; Askari, Bruce
1994-01-01
A primer Computerized Maintenance Management System (CMMS) has been established for NASA Ames pressure component certification program. The CMMS takes full advantage of the latest computer technology and SQL relational database to perform periodic services for vital pressure components. The Ames certification program is briefly described and the aspects of the CMMS implementation are discussed as they are related to the certification objectives.
ERIC Educational Resources Information Center
New England Board of Higher Education, Wellesley, MA. New England Library Information Network.
The potential for using a computerized communication system to facilitate resource sharing in New England has been investigated by the staff of the New England Information Network (NELINET). The central purpose of their research was to determine whether a strategy for load leveling of interlibrary loan (ILL) requests could be implemented online as…
Computerized Design Synthesis (CDS), A database-driven multidisciplinary design tool
NASA Technical Reports Server (NTRS)
Anderson, D. M.; Bolukbasi, A. O.
1989-01-01
The Computerized Design Synthesis (CDS) system under development at McDonnell Douglas Helicopter Company (MDHC) is targeted to make revolutionary improvements in both response time and resource efficiency in the conceptual and preliminary design of rotorcraft systems. It makes the accumulated design database and supporting technology analysis results readily available to designers and analysts of technology, systems, and production, and makes powerful design synthesis software available in a user friendly format.
Rouhani, R; Cronenberger, H; Stein, L; Hannum, W; Reed, A M; Wilhelm, C; Hsiao, H
1995-01-01
This paper describes the design, authoring, and development of interactive, computerized, multimedia clinical simulations in pediatric rheumatology/immunology and related musculoskeletal diseases, the development and implementation of a high speed information management system for their centralized storage and distribution, and analytical methods for evaluating the total system's educational impact on medical students and pediatric residents. An FDDI fiber optic network with client/server/host architecture is the core. The server houses digitized audio, still-image video clips and text files. A host station houses the DB2/2 database containing case-associated labels and information. Cases can be accessed from any workstation via a customized interface in AVA/2 written specifically for this application. OS/2 Presentation Manager controls, written in C, are incorporated into the interface. This interface allows SQL searches and retrievals of cases and case materials. In addition to providing user-directed clinical experiences, this centralized information management system provides designated faculty with the ability to add audio notes and visual pointers to image files. Users may browse through case materials, mark selected ones and download them for utilization in lectures or for editing and converting into 35mm slides.
Reflecting on the ethical administration of computerized medical records
NASA Astrophysics Data System (ADS)
Collmann, Jeff R.
1995-05-01
This presentation examines the ethical issues raised by computerized image management and communication systems (IMAC), the ethical principals that should guide development of policies, procedures and practices for IMACS systems, and who should be involved in developing a hospital's approach to these issues. The ready access of computerized records creates special hazards of which hospitals must beware. Hospitals must maintain confidentiality of patient's records while making records available to authorized users as efficiently as possible. The general conditions of contemporary health care undermine protecting the confidentiality of patient record. Patients may not provide health care institutions with information about themselves under conditions of informed consent. The field of information science must design sophisticated systems of computer security that stratify access, create audit trails on data changes and system use, safeguard patient data from corruption, and protect the databases from outside invasion. Radiology professionals must both work with information science experts in their own hospitals to create institutional safeguards and include the adequacy of security measures as a criterion for evaluating PACS systems. New policies and procedures on maintaining computerized patient records must be developed that obligate all members of the health care staff, not just care givers. Patients must be informed about the existence of computerized medical records, the rules and practices that govern their dissemination and given the opportunity to give or withhold consent for their use. Departmental and hospital policies on confidentiality should be reviewed to determine if revisions are necessary to manage computer-based records. Well developed discussions of the ethical principles and administrative policies on confidentiality and informed consent and of the risks posed by computer-based patient records systems should be included in initial and continuing staff system training. Administration should develop ways to monitor staff compliance with confidentiality policies and should assess diligence in maintaining patient record confidentiality as part of staff annual performance evaluations. Ethical management of IMAC systems is the business of all members of the health care team. Computerized patient records management (including IMAC) should be scrutinized as any other clinical medial ethical issue. If hospitals include these processes in their planning for RIS, IMACS, and HIS systems, they should have time to develop institutional expertise on these questions before and as systems are installed rather than only as ethical dilemmas develop during their use.
NASA Technical Reports Server (NTRS)
Johannes, J. D.
1974-01-01
Techniques, methods, and system requirements are reported for an onboard computerized communications system that provides on-line computing capability during manned space exploration. Communications between man and computer take place by sequential execution of each discrete step of a procedure, by interactive progression through a tree-type structure to initiate tasks or by interactive optimization of a task requiring man to furnish a set of parameters. Effective communication between astronaut and computer utilizes structured vocabulary techniques and a word recognition system.
ERIC Educational Resources Information Center
New Brunswick Dept. of Advanced Education and Training, Fredericton. Interprovincial Standards Program Coordinating Committee.
In January 1985, Employment and Immigration Canada funded a pilot project in New Brunswick for the development and testing of an Interprovincial Computerized Examination Management (ICEM) System. The resulting system is comprised of a dual interprovincial and provincial item bank facility, a software component offering the option of computerized…
Troise Rioda, W.; Nervetti, A.
2001-01-01
The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGoldrick, P.R.
1981-01-01
The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control roommore » consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed.« less
Application of a minicomputer-based system in measuring intraocular fluid dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronzino, J.D.; D'Amato, D.P.; O'Rourke, J.
A complete, computerized system has been developed to automate and display radionuclide clearance studies in an ophthalmology clinical laboratory. The system is based on a PDP-8E computer with a 16-k core memory and includes a dual-drive Decassette system and an interactive display terminal. The software controls the acquisition of data from an NIM scaler, times the procedures, and analyzes and simultaneously displays logarithmically converted data on a fully annotated graph. Animal studies and clinical experiments are presented to illustrate the nature of these displays and the results obtained using this automated eye physiometer.
Fault tree applications within the safety program of Idaho Nuclear Corporation
NASA Technical Reports Server (NTRS)
Vesely, W. E.
1971-01-01
Computerized fault tree analyses are used to obtain both qualitative and quantitative information about the safety and reliability of an electrical control system that shuts the reactor down when certain safety criteria are exceeded, in the design of a nuclear plant protection system, and in an investigation of a backup emergency system for reactor shutdown. The fault tree yields the modes by which the system failure or accident will occur, the most critical failure or accident causing areas, detailed failure probabilities, and the response of safety or reliability to design modifications and maintenance schemes.
Mixed results in the safety performance of computerized physician order entry.
Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C
2010-04-01
Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.
Information technology and medication safety: what is the benefit?
Kaushal, R; Bates, D
2002-01-01
Medication errors occur frequently and have significant clinical and financial consequences. Several types of information technologies can be used to decrease rates of medication errors. Computerized physician order entry with decision support significantly reduces serious inpatient medication error rates in adults. Other available information technologies that may prove effective for inpatients include computerized medication administration records, robots, automated pharmacy systems, bar coding, "smart" intravenous devices, and computerized discharge prescriptions and instructions. In outpatients, computerization of prescribing and patient oriented approaches such as personalized web pages and delivery of web based information may be important. Public and private mandates for information technology interventions are growing, but further development, application, evaluation, and dissemination are required. PMID:12486992
A New Item Selection Procedure for Mixed Item Type in Computerized Classification Testing.
ERIC Educational Resources Information Center
Lau, C. Allen; Wang, Tianyou
This paper proposes a new Information-Time index as the basis for item selection in computerized classification testing (CCT) and investigates how this new item selection algorithm can help improve test efficiency for item pools with mixed item types. It also investigates how practical constraints such as item exposure rate control, test…
F-15 HiDEC in flight over Mojave desert
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's F-15 HIDEC (Highly Integrated Digital Electronic Control) research aircraft cruises over California's Mojave Desert at sunset on a flight out of the Dryden Flight Research Center, Edwards, California. The aircraft was used to carry out research on engine and flight control systems and most recently demonstrated the use of computer-assisted engine controls as a means of landing an aircraft safely with only engine power if its normal control surfaces such as elevators, rudders or ailerons are disabled. The aircraft also tested and evaluated a computerized self-repair flight control system for the Air Force that detects damaged or failed flight control surfaces, and then reconfigures undamaged flight surfaces so the mission can continue or the aircraft is landed safely. Nearly all research being carried out in the HIDEC program is applicable to future civilian and military aircraft.
Documentation of Nursing Practice Using a Computerized Medical Information System
Romano, Carol
1981-01-01
This paper discusses a definition of the content of the computerized nursing data base developed by the Nursing Department for the Clinical Center Medical Information System at the National Institutes of Health in Bethesda, Maryland. The author describes the theoretical framework for the content and presents a model to describe the organization of the nursing data components in relation to the process of nursing care delivery. Nursing documentation requirements of Nurse Practice Acts, American Nurses Association Standards of Practice and the Joint Commission on Accreditation of Hospitals are also addressed as they relate to this data base. The advantages and disadvantages of such an approach to computerized documentation are discussed.
Computerizing Maintenance Management Improves School Processes.
ERIC Educational Resources Information Center
Conroy, Pat
2002-01-01
Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)
KURTH, Ann E.; SPIELBERG, Freya; CLELAND, Charles M.; LAMBDIN, Barrot; BANGSBERG, David R.; FRICK, Pamela A.; SEVERYNEN, Anneleen O.; CLAUSEN, Marc; NORMAN, Robert G.; LOCKHART, David; SIMONI, Jane M.; HOLMES, King K.
2014-01-01
Objective Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Design Longitudinal RCT. Settings An academic HIV clinic and a community-based organization in Seattle. Subjects 240 HIV-positive adults on ART; 209 completed nine-month follow-up (87% retention). Intervention Randomization to computerized counseling or assessment-only, 4 sessions over 9 months. Main Outcome Measures HIV-1 viral suppression, and self-reported ART adherence, and transmission risks, compared using generalized estimating equations. Results Overall, intervention participants had reduced viral load (VL): mean 0.17 log10 decline, versus 0.13 increase in controls, p = 0.053, and significant difference in ART adherence baseline to 9 months (p = 0.046). Their sexual transmission risk behaviors decreased (OR = 0.55, p = 0.020), a reduction not seen among controls (OR = 1.1, p = 0.664), and a significant difference in change (p = 0.040). Intervention effect was driven by those most in need: among those with detectable virus at baseline (>30 copies/milliliter, n=89), intervention effect was mean 0.60 log10 VL decline versus 0.15 increase in controls, p=0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, p = 0.038. Conclusions Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior. PMID:24384803
ERIC Educational Resources Information Center
Muiznieks, Viktors J.; Cox, John
The Computerized Test-Result Reporting System (CTRS), which consists of three programs written in the BASIC language, was developed to analyze obective tests, test items, test results, and to provide the teacher-user with interpreted data about the performance of tests, Lest items, and students. This paper documents the three programs from the…
Computerized Adaptive Testing Project: Objectives and Requirements.
1982-07-01
developing a cqmputerlzed adaptive lwfb system ( CAT ). SiN 0102- LP. Old. "O AM"- S/M "of F.g~ smuuim ftmAYUSN 0 IM ~ A joint-service coordinated effort is In...progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the Military Enlistment Processing Stations...lead laboratory for this effort. This report is intended to serve as a working paper documenting CAT system functional requirements and schedules. It
Blackwell, C.D.
1988-01-01
Codes for the unique identification of public and private organizations listed in computerized data systems are presented. These codes are used by the U.S. Geological Survey 's National Water Data Exchange (NAWDEX), National Water Data Storage and Retrieval System (WATSTORE), National Cartographic Information Center (NCIC), and Office of Water Data Coordination (OWDC). The format structure of the codes is discussed and instructions are given for requesting new books. (Author 's abstract)
Fault Tolerant Considerations and Methods for Guidance and Control Systems
1987-07-01
multifunction devices such as microprocessors with software. In striving toward the economic goal, however, a cost is incurred in a different coin, i.e...therefore been developed which reduces the software risk to acceptable proportions. Several of the techniques thus developed incur no significant cost ...complex that their design and implementation need computerized tools in order to be cost -effective (in a broad sense, including the capability of
Strategic Studies Quarterly. Volume 6, Number 4, Winter 2012
2012-01-01
surfaced in Australia, where a disgruntled employee rigged a computerized control system at a water treatment plant and...strategy" refers to a multilinear whole-of-government method geared to overcome the resistance and effects of a rival’s A2/AD strategy. r * Anti-Access...counterspace tech- nologies, and long-range surface -to-air missiles. To a force that intends to [44] STRATEGIC STUDIES QUARTERLY ♦ WINTER 2012
NASA Astrophysics Data System (ADS)
1981-01-01
Oklahoma City Police Department developed a computerized communications system, based on Johnson Space Center's (JSC's) 1960-mission control knowledge. JSC furnished information on lighting and other fatigue reducing measures, and provided specifications for equipment and design layouts. JSC also advised OCPD how to avoid communications bottlenecks associated with simultaneous handling of telephone, radio and inner-office transmissions. Oklahoma City saved money in reduced design and engineering costs by utilizing the already developed NASA technology.
Operational effectiveness of a Multiple Aquila Control System (MACS)
NASA Technical Reports Server (NTRS)
Brown, R. W.; Flynn, J. D.; Frey, M. R.
1983-01-01
The operational effectiveness of a multiple aquila control system (MACS) was examined under a variety of remotely piloted vehicle (RPV) mission configurations. The set of assumptions and inputs used to form the rules under which a computerized simulation of MACS was run is given. The characteristics that are to govern MACS operations include: the battlefield environment that generates the requests for RPV missions, operating time-lines of the RPV-peculiar equipment, maintenance requirements, and vulnerability to enemy fire. The number of RPV missions and the number of operation days are discussed. Command, control, and communication data rates are estimated by determining how many messages are passed and what information is necessary in them to support ground coordination between MACS sections.
How to Construct an Automated Warehouse Based on Colored Timed Petri Nets
NASA Astrophysics Data System (ADS)
Cheng, Fei; He, Shanjun
The automated warehouse considered here consists of a number of rack locations with three cranes, a narrow aisle shuttle, and several buffer stations with the roller. Based on analyzing of the behaviors of the active resources in the system, a modular and computerized model is presented via a colored timed Petri net approach, in which places are multicolored to simplify model and characterize control flow of the resources, and token colors are defined as the routes of storage/retrieval operations. In addition, an approach for realization of model via visual c++ is briefly given. These facts allow us to render an emulate system to simulate a discrete control application for online monitoring, dynamic dispatching control and off-line revising scheduler policies.
COMPUTERIZED SHAWNEE LIME/LIMESTONE SCRUBBING MODEL USERS MANUAL
The manual gives a general description of a computerized model for estimating design and cost of lime or limestone scrubber systems for flue gas desulfurization (FGD). It supplements PB80-123037 by extending the number of scrubber options which can be evaluated. It includes spray...
Total Library Computerization for Windows.
ERIC Educational Resources Information Center
Combs, Joseph, Jr.
1999-01-01
Presents a general review of features of version 2.1 of Total Library Computerization (TLC) for Windows from On Point, Inc. Includes information about pricing, hardware and operating systems, modules/functions available, user interface, security, on-line catalog functions, circulation, cataloging, and documentation and online help. A table…
Computerized Financial Reporting Based on GAAP.
ERIC Educational Resources Information Center
Tikkanen, Stan; Liljeberg, Burt
1983-01-01
Describes the statewide computerized system developed in Minnesota following the 1976 enactment of the Uniform Financial Accounting and Reporting Standards (UFARS) law. UFARS includes provisions for an advisory council responsible for recommending accounting and reporting procedures, and seven data processing centers to serve all 560 Minnesota…
NASA Technical Reports Server (NTRS)
Hughes, R. O.
1975-01-01
Incremental motion devices provide accurate and rapid movement of spacecraft science platforms, antennas and related mechanisms. The paper considers the computerized simulation of a stepper motor/gear train/ science platform system that will be launched on the Mariner Jupiter Saturn 1977. It was determined that a smaller stepper motor could be used as the prime mover for the science platform, and it was concluded that the existing digital controller was unable to achieve the required pointing accuracy, and a new controller design was necessary.
ERIC Educational Resources Information Center
Pressman, E.; And Others
1986-01-01
The auditory receptive language skills of 40 learning disabled (LD) and 40 non-disabled boys (all 7 - 11 years old) were assessed via computerized versions of subtests of the Goldman-Fristoe-Woodcock Auditory Skills Test Battery. The computerized assessment correctly identified 92.5% of the LD group and 65% of the normal control children. (DB)
ERIC Educational Resources Information Center
Bowler, Jennifer O.; Mackintosh, Bundy; Dunn, Barnaby D.; Mathews, Andrew; Dalgleish, Tim; Hoppitt, Laura
2012-01-01
Objective: Computerized cognitive behavioral therapy (cCBT) and cognitive bias modification for interpretation (CBM-I) both have demonstrated efficacy in alleviating social anxiety, but how they compare with each other has not been investigated. The present study tested the prediction that both interventions would reduce anxiety relative to a…
ERIC Educational Resources Information Center
Kariuki, Patrick N.; Ross, Zachary R.
2017-01-01
The purpose of this study was to investigate the effects of computerized and traditional ear training methods on the aural skills abilities of elementary music students. The sample consisted of 20 students who were randomly assigned to either an experimental or control group. The experimental group was taught for five sessions using computerized…
Non-standard analysis and embedded software
NASA Technical Reports Server (NTRS)
Platek, Richard
1995-01-01
One model for computing in the future is ubiquitous, embedded computational devices analogous to embedded electrical motors. Many of these computers will control physical objects and processes. Such hidden computerized environments introduce new safety and correctness concerns whose treatment go beyond present Formal Methods. In particular, one has to begin to speak about Real Space software in analogy with Real Time software. By this we mean, computerized systems which have to meet requirements expressed in the real geometry of space. How to translate such requirements into ordinary software specifications and how to carry out proofs is a major challenge. In this talk we propose a research program based on the use of no-standard analysis. Much detail remains to be carried out. The purpose of the talk is to inform the Formal Methods community that Non-Standard Analysis provides a possible avenue to attack which we believe will be fruitful.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to Public Welfare OFFICE OF CHILD SUPPORT ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT... payments; (6) Computing and distributing incentive payments to political subdivisions which share in the...
How will computerization revolutionize managed care?
Trabin, T
1994-01-01
Computerization of behavioral health care information systems is revolutionizing how payors, managed care companies, and providers exchange information. In this article, an imaginary scenario is depicted of how patient data will be accessed and communicated to facilitate care management of behavioral health care services in the near future.
Robust Computer-Assisted Laser Treatment Using Real-Time Retinal Tracking
2001-10-25
Abstract- We propose a new computerized system to accurately guide laser shots to the diseased areas within the retina based on predetermined...image registration I. INTRODUCTION Diabetic retinopathy resulting from long term diabetes mellitus is one of the common diseases that lead to choroidal...have a strong impact on the effectiveness of such procedures. In this work, we propose a new computerized treatment planning system for laser treatment
Fourth Year Status Report. Computerized Training Systems Project. Project ABACUS.
1976-08-01
in 7 9. PERFORMING ORGANIZATION NAME AND ADOMEN ,,, 10. PROGRAM ELEMENT. PROJECT , TASK US Army Tra ining Support Center A R E A S WORK UNIT NUMBERS...transp ired during the fourth year of Project ABACUS, the A rmy ’s program for the development of a Computerized Training System. It inc l udes a...have transpired durlnq the fourth year of Project ABACUS, the Army ’s program for the developmen t o~ aprototype Computer i zed Training System. It
Computerized tomography platform using beta rays
NASA Astrophysics Data System (ADS)
Paetkau, Owen; Parsons, Zachary; Paetkau, Mark
2017-12-01
A computerized tomography (CT) system using a 0.1 μCi Sr-90 beta source, Geiger counter, and low density foam samples was developed. A simple algorithm was used to construct images from the data collected with the beta CT scanner. The beta CT system is analogous to X-ray CT as both types of radiation are sensitive to density variations. This system offers a platform for learning opportunities in an undergraduate laboratory, covering topics such as image reconstruction algorithms, radiation exposure, and the energy dependence of absorption.
NASA Astrophysics Data System (ADS)
Monteil, P.
1981-11-01
Computation of the overall levels and spectral densities of the responses measured on a launcher skin, the fairing for instance, merged into a random acoustic environment during take off, was studied. The analysis of transmission of these vibrations to the payload required the simulation of these responses by a shaker control system, using a small number of distributed shakers. Results show that this closed loop computerized digital system allows the acquisition of auto and cross spectral densities equal to those of the responses previously computed. However, wider application is sought, e.g., road and runway profiles. The problems of multiple input-output system identification, multiple true random signal generation, and real time programming are evoked. The system should allow for the control of four shakers.
Reaching out to clinicians: implementation of a computerized alert system.
Degnan, Dan; Merryfield, Dave; Hultgren, Steve
2004-01-01
Several published articles have identified that providing automated, computer-generated clinical alerts about potentially critical clinical situations should result in better quality of care. In 1999, the pharmacy department at a community hospital network implemented and refined a commercially available, computerized clinical alert system. This case report discusses the implementation process, gives examples of how the system is used, and describes results following implementation. The use of the clinical alert system in this hospital network resulted in improved patient safety as well as in greater efficiency and decreased costs.
ERIC Educational Resources Information Center
American School and University, 1982
1982-01-01
Computerized energy management at Drew University (New Jersey) is accomplished by direct digital control in which microprocessor controllers control, monitor, and carry out energy management functions at the equipment level. (Author/MLF)
Power processing methodology. [computerized design of spacecraft electric power systems
NASA Technical Reports Server (NTRS)
Fegley, K. A.; Hansen, I. G.; Hayden, J. H.
1974-01-01
Discussion of the interim results of a program to investigate the feasibility of formulating a methodology for the modeling and analysis of aerospace electrical power processing systems. The object of the total program is to develop a flexible engineering tool which will allow the power processor designer to effectively and rapidly assess and analyze the tradeoffs available by providing, in one comprehensive program, a mathematical model, an analysis of expected performance, simulation, and a comparative evaluation with alternative designs. This requires an understanding of electrical power source characteristics and the effects of load control, protection, and total system interaction.
Preliminary evaluation of a micro-based repeated measures testing system
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.
1985-01-01
A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.
Breitborde, Nicholas J K; Woolverton, Cindy; Dawson, Spencer C; Bismark, Andrew; Bell, Emily K; Bathgate, Christina J; Norman, Kaila
2017-06-01
Meta-cognitive skills training (MST) is a frequent component of cognitive remediation programmes for individuals with psychosis. However, no study has investigated whether incorporating such activities produces increased clinical benefits compared with computerized cognitive remediation alone. Individuals with first-episode psychosis who completed computerized cognitive remediation with concurrent meta-cognitive skills training (CCR + MST) were compared with a historical control group who received computerized cognitive remediation alone (CCR) and did not differ from the CCR + MST group with regard to pre-intervention cognition, diagnosis, age, duration of psychotic illness or sex. Participants completed assessments of cognition and real-world functioning before and after 6 months of treatment. Individual receiving CCR + MST experience greater gains in cognition and real-world functioning than individuals who received CCR. MST may be an important component within cognitive remediation programmes for first-episode psychosis. © 2015 Wiley Publishing Asia Pty Ltd.
Dealing with problem number one--budget cuts: can you do more with less?
2001-09-01
To cope with current budget restraints and cutbacks, hospital security departments are increasingly integrating their manpower with technology in the form of access control, CCTV cameras, and alarm systems to supplement their services as well as becoming more dependent on computerized information technology systems and IT departments to track hospital activities and incidents. Security directors contacted for this report also emphasize that they are doing more with less by providing value-added services both to expand activities and to demonstrate the importance of their departments to top management.
A Computerized Bibliographic Service for the Blind and Physically Handicapped
ERIC Educational Resources Information Center
Friedman, Morton H.
1975-01-01
Describes a three-year plan and a system study designed to produce a computerized union catalog and an in-process file for both the Library of Congress Division for the Blind and Physically Handicapped and a network of almost 200 libraries throughout the nation. (Author/PF)
ERIC Educational Resources Information Center
Reese, Dorothy J.
2012-01-01
The purpose of this quantitative, descriptive/correlational project was to examine the relationship between the level of computer literacy, informatics training, nursing experience, and perceived competence in using computerized patient information systems (CPIS) and nursing resistance to using CPIS. The Nurse Computerized Patient Information…
Computerized Proof Techniques for Undergraduates
ERIC Educational Resources Information Center
Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu
2012-01-01
The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…
The Design of Computerized Practice Fields for Problem Solving and Contextualized Transfer
ERIC Educational Resources Information Center
Riedel, Jens; Fitzgerald, Gail; Leven, Franz; Toenshoff, Burkhard
2003-01-01
Current theories of learning emphasize the importance of learner-centered, active, authentic, environments for meaningful knowledge construction. From this perspective, computerized case-based learning systems afford practice fields for learners to build domain knowledge and problem-solving skills and to support contextualized transfer of…
Code of Federal Regulations, 2011 CFR
2011-10-01
... violence or child abuse); (xi) Indication of an order; (xii) Locate request type (optional); (xiii) Locate... to Public Welfare OFFICE OF CHILD SUPPORT ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT...
Code of Federal Regulations, 2013 CFR
2013-10-01
... violence or child abuse); (xi) Indication of an order; (xii) Locate request type (optional); (xiii) Locate... to Public Welfare OFFICE OF CHILD SUPPORT ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT...
Code of Federal Regulations, 2012 CFR
2012-10-01
... violence or child abuse); (xi) Indication of an order; (xii) Locate request type (optional); (xiii) Locate... to Public Welfare OFFICE OF CHILD SUPPORT ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT...
Code of Federal Regulations, 2011 CFR
2011-10-01
... planning, design, development, installation or enhancement of a computerized support enforcement system as... APD approved by the Office; and (6) The State or local government has ownership rights in software, software modifications and associated documentation that is designed, developed, installed, or enhanced...
Potential of Audiographic Computerized Telelearning for Distance Extension Education.
ERIC Educational Resources Information Center
Verma, Satish; And Others
In the last 10 years, an approach to electronic distance education called audiographic computerized telelearning using standard telephone lines has come to the fore. Telelearning is a cost-effective system which optimizes existing computer facilities and creates a teaching-learning environment that is interactive, efficient, and adaptable to a…
Bilingual Computerized Speech Recognition Screening for Depression Symptoms
ERIC Educational Resources Information Center
Gonzalez, Gerardo; Carter, Colby; Blanes, Erika
2007-01-01
The Voice-Interactive Depression Assessment System (VIDAS) is a computerized speech recognition application for screening depression based on the Center for Epidemiological Studies--Depression scale in English and Spanish. Study 1 included 50 English and 47 Spanish speakers. Study 2 involved 108 English and 109 Spanish speakers. Participants…
Advanced Technology Training Program for the Apparel Industry. Final Report.
ERIC Educational Resources Information Center
El Paso Community Coll., TX.
A project developed rapid response, advanced technology courses that met the apparel market labor needs of the El Paso (Texas) community. Courses were designed for four options: computerized marker making and pattern grading, computerized front office systems, high technology machinery operation, and high technology machinery mechanics. The…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Canfield, K.J.
1984-05-01
An EMCS (Energy Monitoring and Control System) can be described as a system that automatically takes care of routine operation of equipment and provides centralized reporting and override capabilities. Equipment controlled by an EMCS would be heating, ventilating, and air conditioning (HVAC) equipment, air compressors, and small package boiler units. The EMCS would obtain raw information (data) from sensors associated with the equipment and massage the data into useful information. The information obtained from the sensors plus additional information available to the EMCS would be used to control the equipment. The information would also be available to the operator inmore » the form of reports or in response to operator commands for specific information. EMCS are computerized systems that control and monitor energy consuming and producing equipment at Naval facilities. The larger systems have been installed with color-graphics cathode ray tube operator consoles to provide better information to the personnel operating these systems. This report summarizes the work done on defining an adequate operator console and recommends changes to the existing EMCS Guide Specifications.« less
Cryogenics maintenance strategy
NASA Astrophysics Data System (ADS)
Cruzat, Fabiola
2012-09-01
ALMA is an interferometer composed of 66 independent systems, with specific maintenance requirements for each subsystem. To optimize the observation time and reduce downtime maintenance, requirements are very demanding. One subsystem with high maintenance efforts is cryogenics and vacuum. To organize the maintenance, the Cryogenic and Vacuum department is using and implementing different tools. These are monitoring and problem reporting systems and CMMS. This leads to different maintenance approaches: Preventive Maintenance, Corrective Maintenance and Condition Based Maintenance. In order to coordinate activities with other departments the preventive maintenance schedule is kept as flexible as systems allow. To cope with unavoidable failures, the team has to be prepared to work under any condition with the spares on time. Computerized maintenance management system (CMMS) will help to manage inventory control for reliable spare part handling, the correct record of work orders and traceability of maintenance activities. For an optimized approach the department is currently evaluating where preventive or condition based maintenance applies to comply with the individual system demand. Considering the change from maintenance contracts to in-house maintenance will help to minimize costs and increase availability of parts. Due to increased number of system and tasks the cryo team needs to grow. Training of all staff members is mandatory, in depth knowledge must be built up by doing complex maintenance activities in the Cryo group, use of advanced computerized metrology systems.
Computerized Management Information System in a Community Health Nursing Agency
Simmons, DeLanne A.
1981-01-01
The Visiting Nurse Association of Omaha is a nonprofit, voluntary agency providing home health care, preventive care, clinical services, and school health services in an urban-rural setting. It has developed a computerized system which provides for: (1) centralized dictation by service delivery staff; (2) the printing of a uniform clinical, family problem-oriented record; (3) an integrated data base, statistical system, and financial system; and (4) the communication capability to remote stations. (The hardware utilized is an IBM System 34.) Cost effectiveness has been demonstrated by a reduction in cost of visit from $47.02 to $43.79.
The Impact of Emerging Electronic Highway Control Systems on Motorist Information Requirements
NASA Technical Reports Server (NTRS)
Huchingson, R. Dale; Dudek, Conrad L.
1974-01-01
Advanced forms of electronic and computerized control systems are being developed to optimize traffic flow in and between cities. Modern technology permits communication of real-time information via signs and auditory messages and allows motorists to plan ahead for safer and more efficient travel. This paper describes an on-going research program for defining drivers' information needs and behavior in response to various message types and modes of presentation. Human engineer design criteria for real-time displays will be investigated in the laboratory and in research vehicles with field testing in actual city corridors. The results will be incorporated into a design handbook for use by sign design engineers.
Optically controlled welding system
NASA Technical Reports Server (NTRS)
Gordon, Stephen S. (Inventor)
1988-01-01
An optically controlled welding system wherein a welding torch having through-the-torch viewing capabilities is provided with an optical beam splitter to create a transmitted view and a reflective view of a welding operation. These views are converted to digital signals which are then processed and utilized by a computerized robotic welder to make the welding torch responsive thereto. Other features include an actively cooled electrode holder which minimizes a blocked portion of the view by virtue of being constructed of a single spoke or arm, and a weld pool contour detector comprising a laser beam directed onto the weld pool with the position of specular radiation reflected therefrom, being characteristic of a penetrated or unpenetrated condition of the weld pool.
Computerized Integrated Inventory Control for an Air Force Base-Level Supply System.
1980-06-01
3465 4710-4730 9110-9180 3515-3540 4810-4820 9320-9360 3620-3694 4910-4940 9505 -9540 3720-2750 5110-5180 9620-9650 3805-3030 5210-5280 3910-3995 4010...Buffers Disc Files Input 1.2 K Output 1.2 K 2.4 K Printer 2 (double) x 150 .0003 K Tape Input 1.2 K Output 1.2 K 2.4 K Card Reader 2 (double) x 100 . 0002
Progress on Intelligent Guidance and Control for Wind Shear Encounter
NASA Technical Reports Server (NTRS)
Stratton, D. Alexander
1990-01-01
Low altitude wind shear poses a serious threat to air safety. Avoiding severe wind shear challenges the ability of flight crews, as it involves assessing risk from uncertain evidence. A computerized intelligent cockpit aid can increase flight crew awareness of wind shear, improving avoidance decisions. The primary functions of a cockpit advisory expert system for wind shear avoidance are discussed. Also introduced are computational techniques being implemented to enable these primary functions.
2011-01-01
clinical decision- making paradigms, coupled with regula- tory and technical limitations, is just one of the hurdles that has kept advanced information...responses to assist care personnel during the resuscitation phase. CDSSs have been successfully used in the clinical setting for several years (23–24...because of clinical complications, death, or other factors were excluded. The control cohort included only patients who sur- vived for the initial 24
ERIC Educational Resources Information Center
McNeil, Malcolm R.; Pratt, Sheila R.; Szuminsky, Neil; Sung, Jee Eun; Fossett, Tepanta R. D.; Fassbinder, Wiltrud; Lim, Kyoung Yuel
2015-01-01
Purpose: This study assessed the reliability and validity of intermodality associations and differences in persons with aphasia (PWA) and healthy controls (HC) on a computerized listening and 3 reading versions of the Revised Token Test (RTT; McNeil & Prescott, 1978). Method: Thirty PWA and 30 HC completed the test versions, including a…
An automated atmospheric sampling system operating on 747 airliners
NASA Technical Reports Server (NTRS)
Perkins, P. J.; Gustafsson, U. R. C.
1976-01-01
An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.
Data Mining on Numeric Error in Computerized Physician Order Entry System Prescriptions.
Wu, Xue; Wu, Changxu
2017-01-01
This study revealed the numeric error patterns related to dosage when doctors prescribed in computerized physician order entry system. Error categories showed that the '6','7', and '9' key produced a higher incidence of errors in Numpad typing, while the '2','3', and '0' key produced a higher incidence of errors in main keyboard digit line typing. Errors categorized as omission and substitution were higher in prevalence than transposition and intrusion.
A WebGIS-based command control system for forest fire fighting
NASA Astrophysics Data System (ADS)
Yang, Jianyu; Ming, Dongping; Zhang, Xiaodong; Huang, Haitao
2006-10-01
Forest is a finite resource and fire prevention is crucial work. However, once a forest fire or accident occurs, timely and effective fire-fighting is the only necessary measure. The aim of this research is to build a computerized command control system based on WEBGIS to direct fire-fighting. Firstly, this paper introduces the total technique flow and functional modules of the system. Secondly, this paper analyses the key techniques for building the system, and they are data obtaining, data organizing & management, architecture of WebGIS and sharing & interoperation technique. In the end, this paper demonstrates the on line martial symbol editing function to show the running result of system. The practical application of this system showed that it played very important role in the forest fire fighting work. In addition, this paper proposes some strategic recommendations for the further development of the system.
Leung, Gabriel M.; Yu, Philip L. H.; Wong, Irene O. L.; Johnston, Janice M.; Tin, Keith Y. K.
2003-01-01
Objective: Given the slow adoption of medical informatics in Hong Kong and Asia, we sought to understand the contributory barriers and potential incentives associated with information technology implementation. Design and Measurements: A representative sample of 949 doctors (response rate = 77.0%) was asked through a postal survey to rank a list of nine barriers associated with clinical computerization according to self-perceived importance. They ranked seven incentives or catalysts that may influence computerization. We generated mean rank scores and used multidimensional preference analysis to explore key explanatory dimensions of these variables. A hierarchical cluster analysis was performed to identify homogenous subgroups of respondents. We further determined the relationships between the sets of barriers and incentives/catalysts collectively using canonical correlation. Results: Time costs, lack of technical support and large capital investments were the biggest barriers to computerization, whereas improved office efficiency and better-quality care were ranked highest as potential incentives to computerize. Cost vs. noncost, physician-related vs. patient-related, and monetary vs. nonmonetary factors were the key dimensions explaining the barrier variables. Similarly, within-practice vs external and “push” vs “pull” factors accounted for the incentive variables. Four clusters were identified for barriers and three for incentives/catalysts. Canonical correlation revealed that respondents who were concerned with the costs of computerization also perceived financial incentives and government regulation to be important incentives/catalysts toward computerization. Those who found the potential interference with communication important also believed that the promise of improved care from computerization to be a significant incentive. Conclusion: This study provided evidence regarding common barriers associated with clinical computerization. Our findings also identified possible incentive strategies that may be employed to accelerate uptake of computer systems. PMID:12595409
Can computerized tomography accurately stage childhood renal tumors?
Abdelhalim, Ahmed; Helmy, Tamer E; Harraz, Ahmed M; Abou-El-Ghar, Mohamed E; Dawaba, Mohamed E; Hafez, Ashraf T
2014-07-01
Staging of childhood renal tumors is crucial for treatment planning and outcome prediction. We sought to identify whether computerized tomography could accurately predict the local stage of childhood renal tumors. We retrospectively reviewed our database for patients diagnosed with childhood renal tumors and treated surgically between 1990 and 2013. Inability to retrieve preoperative computerized tomography, intraoperative tumor spillage and nonWilms childhood renal tumors were exclusion criteria. Local computerized tomography stage was assigned by a single experienced pediatric radiologist blinded to the pathological stage, using a consensus similar to the Children's Oncology Group Wilms tumor staging system. Tumors were stratified into up-front surgery and preoperative chemotherapy groups. The radiological stage of each tumor was compared to the pathological stage. A total of 189 tumors in 179 patients met inclusion criteria. Computerized tomography staging matched pathological staging in 68% of up-front surgery (70 of 103), 31.8% of pre-chemotherapy (21 of 66) and 48.8% of post-chemotherapy scans (42 of 86). Computerized tomography over staged 21.4%, 65.2% and 46.5% of tumors in the up-front surgery, pre-chemotherapy and post-chemotherapy scans, respectively, and under staged 10.7%, 3% and 4.7%. Computerized tomography staging was more accurate in tumors managed by up-front surgery (p <0.001) and those without extracapsular extension (p <0.001). The validity of computerized tomography staging of childhood renal tumors remains doubtful. This staging is more accurate for tumors treated with up-front surgery and those without extracapsular extension. Preoperative computerized tomography can help to exclude capsular breach. Treatment strategy should be based on surgical and pathological staging to avoid the hazards of inaccurate staging. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Miller, A; Pilcher, D; Mercaldo, N; Leong, T; Scheinkestel, C; Schildcrout, J
2010-08-01
Screen designs in computerized clinical information systems (CIS) have been modeled on their paper predecessors. However, limited understanding about how paper forms support clinical work means that we risk repeating old mistakes and creating new opportunities for error and inefficiency as illustrated by problems associated with computerized provider order entry systems. This study was designed to elucidate principles underlying a successful ICU paper-based CIS. The research was guided by two exploratory hypotheses: (1) paper-based artefacts (charts, notes, equipment, order forms) are used differently by nurses, doctors and other healthcare professionals in different (formal and informal) conversation contexts and (2) different artefacts support different decision processes that are distributed across role-based conversations. All conversations undertaken at the bedsides of five patients were recorded with any supporting artefacts for five days per patient. Data was coded according to conversational role-holders, clinical decision process, conversational context and artefacts. 2133 data points were analyzed using Poisson logistic regression analyses. Results show significant interactions between artefacts used during different professional conversations in different contexts (chi(2)((df=16))=55.8, p<0.0001). The interaction between artefacts used during different professional conversations for different clinical decision processes was not statistically significant although all two-way interactions were statistically significant. Paper-based CIS have evolved to support complex interdisciplinary decision processes. The translation of two design principles - support interdisciplinary perspectives and integrate decision processes - from paper to computerized CIS may minimize the risks associated with computerization. 2010 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Recovery of postural equilibrium control following space flight
NASA Technical Reports Server (NTRS)
Paloski, William H.; Reschke, Millard F.; Black, F. Owen; Dow, R. S.
1999-01-01
DSO 605 represents the first large study of balance control following spaceflight. Data collected during DSO 605 confirm the theory that postural ataxia following short duration spaceflight is of vestibular origin. We used the computerized dynamic posturography technique developed by Nashner et al. to study the role of the vestibular system in balance control in astronauts during quiet stance before and after spaceflight. Our results demonstrate unequivocally that balance control is disrupted in all astronauts immediately after return from space. The most severely affected returning crew members performed in the same way as vestibular deficient patients exposed to this test battery. We conclude that otolith mediated spatial reference provided by the terrestrial gravitational force vector is not used by the astronauts balance control systems immediately after spaceflight. Because the postflight ataxia appears to be mediated primarily by CNS adaptation to the altered vestibular inputs caused by loss of gravitational stimulation, we believe that intermittent periods of exposure to artificial gravity may provide an effective in-flight countermeasure. Specifically, we propose that in-flight centrifugation will allow crew members to retain their terrestrial sensory-motor adapted states while simultaneously developing microgravity adapted states. The dual-adapted astronaut should be able to make the transition from microgravity to unit gravity with minimal sensory-motor effects. We have begun a ground based program aimed at developing short arm centrifuge prescriptions designed to optimize adaptation to altered gravitational environments. Results from these experiments are expected to lead directly to in-flight evaluation of the proposed centrifuge countermeasure. Because our computerized dynamic posturography system was able to (1) quantify the postflight postural ataxia reported by crew members and observed by flight surgeons and scientists, (2) track the recovery of normal (preflight) balance control, (3) differentiate between rookie and veteran subjects, and (4) provide normative and clinical databases for comparison, and because our study successfully characterized postflight balance control recovery in a large cross-section of Shuttle crew members, we recommend that this system and protocol be adopted as a standard dependent measure for evaluating the efficacy of countermeasures and/or evaluating the postflight effects of changing mission durations or activities.
Outpatient Prescribing Errors and the Impact of Computerized Prescribing
Gandhi, Tejal K; Weingart, Saul N; Seger, Andrew C; Borus, Joshua; Burdick, Elisabeth; Poon, Eric G; Leape, Lucian L; Bates, David W
2005-01-01
Background Medication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or the impact of computerized prescribing in this setting. Objective To assess the rates, types, and severity of outpatient prescribing errors and understand the potential impact of computerized prescribing. Design Prospective cohort study in 4 adult primary care practices in Boston using prescription review, patient survey, and chart review to identify medication errors, potential adverse drug events (ADEs) and preventable ADEs. Participants Outpatients over age 18 who received a prescription from 24 participating physicians. Results We screened 1879 prescriptions from 1202 patients, and completed 661 surveys (response rate 55%). Of the prescriptions, 143 (7.6%; 95% confidence interval (CI) 6.4% to 8.8%) contained a prescribing error. Three errors led to preventable ADEs and 62 (43%; 3% of all prescriptions) had potential for patient injury (potential ADEs); 1 was potentially life-threatening (2%) and 15 were serious (24%). Errors in frequency (n=77, 54%) and dose (n=26, 18%) were common. The rates of medication errors and potential ADEs were not significantly different at basic computerized prescribing sites (4.3% vs 11.0%, P=.31; 2.6% vs 4.0%, P=.16) compared to handwritten sites. Advanced checks (including dose and frequency checking) could have prevented 95% of potential ADEs. Conclusions Prescribing errors occurred in 7.6% of outpatient prescriptions and many could have harmed patients. Basic computerized prescribing systems may not be adequate to reduce errors. More advanced systems with dose and frequency checking are likely needed to prevent potentially harmful errors. PMID:16117752
Nuclear technology requires free elections
NASA Astrophysics Data System (ADS)
Synek, Miroslav
1999-10-01
The historical development on our planet has reached a powerful technology of nuclear intercontinental ballistic missiles, conceivably controllable through a computerized ``push-button." If this technology ever falls under the control of an irresponsible, miscalculating, or insane DICTATOR, with powerful means of a mass-produced nuclear built-up, anywhere on our planet, the very SURVIVAL OF ALL HUMANITY on our planet could be threatened. Therefore, it is a historical urgency that this technology is under the control by the people, through a sufficiently secure system of FREE ELECTIONS, in any country, wherever and whenever such a threatening possibility exists. Of course, a starting system of FREE ELECTIONS, even if quite rudimentary, should try to provide for its continuous functioning, with an underlying appropriate freedom of expression and with rules for its continuation, while aiming towards continuous improvements.
Model-based reasoning in SSF ECLSS
NASA Technical Reports Server (NTRS)
Miller, J. K.; Williams, George P. W., Jr.
1992-01-01
The interacting processes and reconfigurable subsystems of the Space Station Freedom Environmental Control and Life Support System (ECLSS) present a tremendous technical challenge to Freedom's crew and ground support. ECLSS operation and problem analysis is time-consuming for crew members and difficult for current computerized control, monitoring, and diagnostic software. These challenges can be at least partially mitigated by the use of advanced techniques such as Model-Based Reasoning (MBR). This paper will provide an overview of MBR as it is being applied to Space Station Freedom ECLSS. It will report on work being done to produce intelligent systems to help design, control, monitor, and diagnose Freedom's ECLSS. Specifically, work on predictive monitoring, diagnosability, and diagnosis, with emphasis on the automated diagnosis of the regenerative water recovery and air revitalization processes will be discussed.
Design and validation of an automated hydrostatic weighing system.
McClenaghan, B A; Rocchio, L
1986-08-01
The purpose of this study was to design and evaluate the validity of an automated technique to assess body density using a computerized hydrostatic weighing system. An existing hydrostatic tank was modified and interfaced with a microcomputer equipped with an analog-to-digital converter. Software was designed to input variables, control the collection of data, calculate selected measurements, and provide a summary of the results of each session. Validity of the data obtained utilizing the automated hydrostatic weighing system was estimated by: evaluating the reliability of the transducer/computer interface to measure objects of known underwater weight; comparing the data against a criterion measure; and determining inter-session subject reliability. Values obtained from the automated system were found to be highly correlated with known underwater weights (r = 0.99, SEE = 0.0060 kg). Data concurrently obtained utilizing the automated system and a manual chart recorder were also found to be highly correlated (r = 0.99, SEE = 0.0606 kg). Inter-session subject reliability was determined utilizing data collected on subjects (N = 16) tested on two occasions approximately 24 h apart. Correlations revealed high relationships between measures of underwater weight (r = 0.99, SEE = 0.1399 kg) and body density (r = 0.98, SEE = 0.00244 g X cm-1). Results indicate that a computerized hydrostatic weighing system is a valid and reliable method for determining underwater weight.
Research on ARM Numerical Control System
NASA Astrophysics Data System (ADS)
Wei, Xu; JiHong, Chen
Computerized Numerical Control (CNC) machine tools is the foundation of modern manufacturing systems, whose advanced digital technology is the key to solve the problem of sustainable development of machine tool manufacturing industry. The paper is to design CNC system embedded on ARM and indicates the hardware design and the software systems supported. On the hardware side: the driving chip of the motor control unit, as the core of components, is MCX314AL of DSP motion control which is developed by NOVA Electronics Co., Ltd. of Japan. It make convenient to control machine because of its excellent performance, simple interface, easy programming. On the Software side, the uC/OS-2 is selected as the embedded operating system of the open source, which makes a detailed breakdown of the modules of the CNC system. Those priorities are designed according to their actual requirements. The ways of communication between the module and the interrupt response are so different that it guarantees real-time property and reliability of the numerical control system. Therefore, it not only meets the requirements of the current social precision machining, but has good man-machine interface and network support to facilitate a variety of craftsmen use.
Automated control of hierarchical systems using value-driven methods
NASA Technical Reports Server (NTRS)
Pugh, George E.; Burke, Thomas E.
1990-01-01
An introduction is given to the Value-driven methodology, which has been successfully applied to solve a variety of difficult decision, control, and optimization problems. Many real-world decision processes (e.g., those encountered in scheduling, allocation, and command and control) involve a hierarchy of complex planning considerations. For such problems it is virtually impossible to define a fixed set of rules that will operate satisfactorily over the full range of probable contingencies. Decision Science Applications' value-driven methodology offers a systematic way of automating the intuitive, common-sense approach used by human planners. The inherent responsiveness of value-driven systems to user-controlled priorities makes them particularly suitable for semi-automated applications in which the user must remain in command of the systems operation. Three examples of the practical application of the approach in the automation of hierarchical decision processes are discussed: the TAC Brawler air-to-air combat simulation is a four-level computerized hierarchy; the autonomous underwater vehicle mission planning system is a three-level control system; and the Space Station Freedom electrical power control and scheduling system is designed as a two-level hierarchy. The methodology is compared with rule-based systems and with other more widely-known optimization techniques.
Truyers, Carla; Lesaffre, Emmanuel; Bartholomeeusen, Stefaan; Aertgeerts, Bert; Snacken, René; Brochier, Bernard; Yane, Fernande; Buntinx, Frank
2010-03-22
Computerized morbidity registration networks might serve as early warning systems in a time where natural epidemics such as the H1N1 flu can easily spread from one region to another. In this contribution we examine whether general practice based broad-spectrum computerized morbidity registration networks have the potential to act as a valid surveillance instrument of frequently occurring diseases. We compare general practice based computerized data assessing the frequency of influenza-like illness (ILI) and acute respiratory infections (ARI) with data from a well established case-specific sentinel network, the European Influenza Surveillance Scheme (EISS). The overall frequency and trends of weekly ILI and ARI data are compared using both networks. Detection of influenza-like illness and acute respiratory illness occurs equally fast in EISS and the computerized network. The overall frequency data for ARI are the same for both networks, the overall trends are similar, but the increases and decreases in frequency do not occur in exactly the same weeks. For ILI, the overall rate was slightly higher for the computerized network population, especially before the increase of ILI, the overall trend was almost identical and the increases and decreases occur in the same weeks for both networks. Computerized morbidity registration networks are a valid tool for monitoring frequent occurring respiratory diseases and the detection of sudden outbreaks.
Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh
2015-04-22
Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.
A Computerized Library and Evaluation System for Integral Neutron Experiments.
ERIC Educational Resources Information Center
Hampel, Viktor E.; And Others
A computerized library of references to integral neutron experiments has been developed at the Lawrence Radiation Laboratory at Livermore. This library serves as a data base for the systematic retrieval of documents describing diverse critical and bulk nuclear experiments. The evaluation and reduction of the physical parameters of the experiments…
Policy Manual for a Computerized Search Service in an Academic Library.
ERIC Educational Resources Information Center
Jackson, William J.
This proposed policy manual for the computerized information retrieval service of the University of Houston System outlines policies for specific elements of its operation: (1) users--who is/is not eligible for service and for equipment use; (2) cost--rates charged; (3) responsibilities of searchers--maintenance of searching skills, scheduling of…
ERIC Educational Resources Information Center
Choi, Seung W.; Podrabsky, Tracy; McKinney, Natalie
2012-01-01
Computerized adaptive testing (CAT) enables efficient and flexible measurement of latent constructs. The majority of educational and cognitive measurement constructs are based on dichotomous item response theory (IRT) models. An integral part of developing various components of a CAT system is conducting simulations using both known and empirical…
ERIC Educational Resources Information Center
Chen, Chung-Yang; Teng, Kao-Chiuan
2011-01-01
This paper presents a computerized tool support, the Meetings-Flow Project Collaboration System (MFS), for designing, directing and sustaining the collaborative teamwork required in senior projects in software engineering (SE) education. Among many schools' SE curricula, senior projects serve as a capstone course that provides comprehensive…
NASA Technical Reports Server (NTRS)
Ambs, P.; Fainman, Y.; Esener, S.; Lee, S. H.
1988-01-01
Holographic optical elements (HOEs) of space-variant impulse response have been designed and generated using a computerized optical system. HOEs made of dichromated gelatin have been produced and used for spatial light modulator defect removal and optical interconnects. Experimental performance and characteristics are presented.
Computerized Production Process Planning. Volume 2. Benefit Analysis.
1976-11-01
advantage , in the long term, Systems 2 and 3 will return greater economic benefits . Plots of the cumulative present value of the cash flow by year are...is economically viable for large parts manufac- turers and does offer significant advantages over Systems I and 2 in terms of intangible benefits ...AD-RI51 996 COMPUTERIZED PRODUCTION PROCESS PLANNING VOLUME 2 i/1.. BENEFIT ANRLYSIS(U) IIT RESEARCH INST CHICRGO IL SH H HU ET AL. NOV 76 DAAHNi-76
Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B
2018-06-01
We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.
Barcia, C; De Pablos, V; Bautista-Hernández, V; Sanchez-Bahillo, A; Fernández-Barreiro, A; Poza, M; Herrero, M T
2004-03-15
The parkinsonian symptoms of primates after MPTP exposure can be measured by several visual methods (classical motor scores). However, these methods have a subjective bias, especially as regards the evaluation of the motor activity. Computerized monitoring systems represent an unbiased method for measuring the motor disability of monkeys after MPTP administration. In this work the motor activity of monkeys before and after MPTP administration is measured and compared with the activity of a control intact group by means of a telemetry system. A pronounced decrease in motor activity was observed after MPTP administration. These results suggest the monitoring method used is suited for characterizing the motor incapacity and possible improvements following treatments to test different therapies to control Parkinson's disease in MPTP models involving primates.
Laloyaux, Julien; Van der Linden, Martial; Levaux, Marie-Noëlle; Mourad, Haitham; Pirri, Anthony; Bertrand, Hervé; Domken, Marc-André; Adam, Stéphane; Larøi, Frank
2014-07-30
Difficulties in everyday life activities are core features of persons diagnosed with schizophrenia and in particular during multitasking activities. However, at present, patients׳ multitasking capacities have not been adequately examined in the literature due to the absence of suitable assessment strategies. We thus recently developed a computerized real-life activity task designed to take into account the complex and multitasking nature of certain everyday life activities where participants are required to prepare a room for a meeting. Twenty-one individuals diagnosed with schizophrenia and 20 matched healthy controls completed the computerized task. Patients were also evaluated with a cognitive battery, measures of symptomatology and real world functioning. To examine the ecological validity, 14 other patients were recruited and were given the computerized version and a real version of the meeting preparation task. Results showed that performance on the computerized task was significantly correlated with executive functioning, pointing to the major implication of these cognitive processes in multitasking situations. Performance on the computerized task also significantly predicted up to 50% of real world functioning. Moreover, the computerized task demonstrated good ecological validity. These findings suggest the importance of evaluating multitasking capacities in patients diagnosed with schizophrenia in order to predict real world functioning. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo
2015-11-01
There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Fiber laser-microscope system for femtosecond photodisruption of biological samples
Yavaş, Seydi; Erdogan, Mutlu; Gürel, Kutan; Ilday, F. Ömer; Eldeniz, Y. Burak; Tazebay, Uygar H.
2012-01-01
We report on the development of a ultrafast fiber laser-microscope system for femtosecond photodisruption of biological targets. A mode-locked Yb-fiber laser oscillator generates few-nJ pulses at 32.7 MHz repetition rate, amplified up to ∼125 nJ at 1030 nm. Following dechirping in a grating compressor, ∼240 fs-long pulses are delivered to the sample through a diffraction-limited microscope, which allows real-time imaging and control. The laser can generate arbitrary pulse patterns, formed by two acousto-optic modulators (AOM) controlled by a custom-developed field-programmable gate array (FPGA) controller. This capability opens the route to fine optimization of the ablation processes and management of thermal effects. Sample position, exposure time and imaging are all computerized. The capability of the system to perform femtosecond photodisruption is demonstrated through experiments on tissue and individual cells. PMID:22435105
Weir, Charlene R; Nebeker, Jonathan J R; Hicken, Bret L; Campo, Rebecca; Drews, Frank; Lebar, Beth
2007-01-01
Computerized Provider Order Entry (CPOE) with electronic documentation, and computerized decision support dramatically changes the information environment of the practicing clinician. Prior work patterns based on paper, verbal exchange, and manual methods are replaced with automated, computerized, and potentially less flexible systems. The objective of this study is to explore the information management strategies that clinicians use in the process of adapting to a CPOE system using cognitive task analysis techniques. Observation and semi-structured interviews were conducted with 88 primary-care clinicians at 10 Veterans Administration Medical Centers. Interviews were taped, transcribed, and extensively analyzed to identify key information management goals, strategies, and tasks. Tasks were aggregated into groups, common components across tasks were clarified, and underlying goals and strategies identified. Nearly half of the identified tasks were not fully supported by the available technology. Six core components of tasks were identified. Four meta-cognitive information management goals emerged: 1) Relevance Screening; 2) Ensuring Accuracy; 3) Minimizing memory load; and 4) Negotiating Responsibility. Strategies used to support these goals are presented. Users develop a wide array of information management strategies that allow them to successfully adapt to new technology. Supporting the ability of users to develop adaptive strategies to support meta-cognitive goals is a key component of a successful system.
Lee, Seonah
2013-10-01
This study aimed to organize the system features of decision support technologies targeted at nursing practice into assessment, problem identification, care plans, implementation, and outcome evaluation. It also aimed to identify the range of the five stage-related sequential decision supports that computerized clinical decision support systems provided. MEDLINE, CINAHL, and EMBASE were searched. A total of 27 studies were reviewed. The system features collected represented the characteristics of each category from patient assessment to outcome evaluation. Several features were common across the reviewed systems. For the sequential decision support, all of the reviewed systems provided decision support in sequence for patient assessment and care plans. Fewer than half of the systems included problem identification. There were only three systems operating in an implementation stage and four systems in outcome evaluation. Consequently, the key steps for sequential decision support functions were initial patient assessment, problem identification, care plan, and outcome evaluation. Providing decision support in such a full scope will effectively help nurses' clinical decision making. By organizing the system features, a comprehensive picture of nursing practice-oriented computerized decision support systems was obtained; however, the development of a guideline for better systems should go beyond the scope of a literature review.
Goldberg, H. I.; Neighbor, W. E.; Cheadle, A. D.; Ramsey, S. D.; Diehr, P.; Gore, E.
2000-01-01
OBJECTIVE: To explore the feasibility of conducting unobtrusive interventional research in community practice settings by integrating firm-system techniques with time-series analysis of relational-repository data. STUDY SETTING: A satellite teaching clinic divided into two similar, but geographically separated, primary care group practices called firms. One firm was selected by chance to receive the study intervention. Forty-two providers and 2,655 patients participated. STUDY DESIGN: A nonrandomized controlled trial of computer-generated preventive reminders. Net effects were determined by quantitatively combining population-level data from parallel experimental and control interrupted time series extending over two-month baseline and intervention periods. DATA COLLECTION: Mean rates at which mammography, colorectal cancer screening, and cholesterol testing were performed on patients due to receive each maneuver at clinic visits were the trial's outcome measures. PRINCIPAL FINDINGS: Mammography performance increased on the experimental firm by 154 percent (0.24 versus 0.61, p = .03). No effect on fecal occult blood testing was observed. Cholesterol ordering decreased on both the experimental (0.18 versus 0.1 1, p = .02) and control firms (0.13 versus 0.07, p = .03) coincident with national guidelines retreating from recommending screening for young adults. A traditional uncontrolled interrupted time-series design would have incorrectly attributed the experimental-firm decrease to the introduction of reminders. The combined analysis properly indicated that no net prompting effect had occurred, as the difference between firms in cholesterol testing remained stochastically stable over time (0.05 versus 0.04, p = .75). A logistic-regression analysis applied to individual-level data produced equivalent findings. The trial incurred no supplementary data collection costs. CONCLUSIONS: The apparent validity and practicability of our reminder implementation study should encourage others to develop computerized firm systems capable of conducting controlled time-series trials. Images Fig. 1 PMID:10737451
Ayhan, Cigdem; Bilgin, Sevil; Aksoy, Songul; Yakut, Yavuz
2016-08-10
Automatic and voluntary body position control is essential for postural stability; however, little is known about individual factors that impair the sensorimotor system associated with low back pain (LBP). To evaluate automatic and voluntary motor control impairments causing postural instability in patients with LBP. Motor control impairments associated with poor movement and balance control were analyzed prospectively in 32 patients with LBP. Numeric Rating Scale (NRS) for pain assessment, Oswestry Disability Index (ODI) for disability measurement, and computerized dynamic posturography (CDP) for analysis of postural responses were used to measure outcomes of all patients. Computerized dynamic posturography tests including Sensory organization test (SOT), limits of stability test (movement velocity, directional control, endpoint, and maximum excursion), rhythmic weight shift (rhythmic movement speed and directional control), and adaptation test (toes-up and toes-down tests) were performed and the results compared with NeuroCom normative data. The mean age of the patients was 40.50 ± 12.28 years. Lower equilibrium scores were observed in SOT (p < 0.05). There was a significant increase in reaction time and decrease in movement velocity, directional control, and endpoint excursion (p < 0.05). Speed of rhythmic movement along the anteroposterior direction decreased, while speed increased along the lateral direction (p < 0.05). Poor directional control was recorded in the anteroposterior direction (p < 0.05). Toes-down test showed an increased COG sway in patients compared with that in the controls (p < 0.05). LBP causes poor voluntary control of body positioning, a reduction in movement control, delays in movement initiation, and a difficulty to adapt to sudden surface changes.
Computerized tabletop games as a form of a video game training for old-old.
Cujzek, Marina; Vranic, Andrea
2017-11-01
This research aimed at investigating the utility of a computerized version of a cognitively stimulating activity as a video game intervention for elderly. The study focused on the effect of a 6-week extensive practice intervention on aspects of cognitive functioning (vigilance, working memory (WM), inhibition, reasoning) of old-old participants (N = 29), randomly assigned to trained or active control group. The difference between groups was in the content of the extended video game practice - cognitively complex card game for trained and computerized version of a simple dice-game of chance for control participants. A pretest, posttest and a 4-month follow-up measurement was conducted. Results revealed improvements in both groups, except for improved reasoning found only in trained participants. These results suggest that: (1) improvements are dependent on the complexity of the program, (2) cognitively stimulating activity are a valid training procedure for old-old, (3) novelty of computer use is an important factor in determining training efficacy.
Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N
2014-12-02
Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60-85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [(18)F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults.
Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N
2014-01-01
Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60–85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [18F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults. PMID:25463973
Julius Gy Fabos; Kimball H. Ferris
1977-01-01
This paper justifies and illustrates (in simplified form) a landscape planning approach to the environmental management of the metropolitan landscape. The model utilizes a computerized assessment and mapping system, which exhibits a recent advancement in computer technology that allows for greater accuracy and the weighting of different values when mapping at the...
Computerized Placement Management Software (CPMS): User Manual, Version 3.0.
ERIC Educational Resources Information Center
College Entrance Examination Board, Princeton, NJ.
This guide is designed to enable the beginner, as well as the advanced user, to understand and use the Computerized Placement Management Software (CPMS). The CPMS is a system for evaluating information about students and recommending their placement into courses best suited for them. It also tracks their progress and maintains their records. The…
The Child Well-Being Scales as a Clinical Tool and a Management Information System.
ERIC Educational Resources Information Center
Lyons, Peter; Doueck, Howard J.; Koster, Andrew J.; Witzky, Melissa K.; Kelly, Patricia L.
1999-01-01
Describes implementation of a computerized version of the Child Welfare League of America's Child Well-Being Scales by a family services agency in southern Ontario. Reviews results obtained from 172 families to illustrate the potential for using computerized risk assessment as an aid in clinical, supervisory, and management decision-making…
Code of Federal Regulations, 2010 CFR
2010-10-01
... applicable matching rate.) (c) HHS rights to software. The Department of Health and Human Services reserves a...), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT... APD approved by the Office; and (6) The State or local government has ownership rights in software...
NASA Technical Reports Server (NTRS)
Proctor, B. W.; Reysa, R. P.; Russell, D. J.
1975-01-01
A review of crew appliance related literature was made to provide background engineering information for development of conceptual appliance systems for the shuttle orbiter and the modular space station. From this review, a file containing abstracts of 299 appliance-related documents coded according to subject was developed along with a computerized bibliography of 682 references. Trade studies were conducted using information from these references to determine the optimum concepts to satisfy the shuttle and space station mission requirements. An appliance system was devised for each vehicle which has minimum impact to the respective environmental control system with the smallest possible weight, volume, and electrical penalty. Engineering parameters for each appliance concept considered are presented along with the total thermal and electrical loads and weight and volume penalties for each of the optimized appliance systems.
NASA Technical Reports Server (NTRS)
Washburn, David A.; Rumbaugh, Duane M.
1992-01-01
Nonhuman primates provide useful models for studying a variety of medical, biological, and behavioral topics. Four years of joystick-based automated testing of monkeys using the Language Research Center's Computerized Test System (LRC-CTS) are examined to derive hints and principles for comparable testing with other species - including humans. The results of multiple parametric studies are reviewed, and reliability data are presented to reveal the surprises and pitfalls associated with video-task testing of performance.
Rolfe, Mei Hsin Suzanne; Hamm, Jeff P; Waldie, Karen E
2008-03-01
Two versions of the line bisection task, paper-and-pencil and computerized, were administered to non-medicated children (5-12 years) with and without Attention-Deficit/Hyperactivity Disorder (ADHD). Fifteen children were classified with ADHD-Inattentive type (ADHD-I), 15 were classified with ADHD-Combined or Hyperactive-Impulsive type (ADHD-C), and 15 children served as controls. During the paper-and-pencil task, and irrespective of hand-use, participants with ADHD-C bisected lines with a right bias, whereas participants with ADHD-I showed a leftwards bias. Interestingly, during the computerized version, an opposite pattern of hemineglect was observed with a leftwards bias for participants with ADHD-C and a rightwards bias for participants with ADHD-I. These findings suggest that different task demands are associated with the paper-and-pencil and computerized tasks. The findings also suggest that the two subtypes differ according to their cognitive profile, and possibly differ as to their underlying neural impairment.
Bogdanova, Yelena; Yee, Megan K; Ho, Vivian T; Cicerone, Keith D
Comprehensive review of the use of computerized treatment as a rehabilitation tool for attention and executive function in adults (aged 18 years or older) who suffered an acquired brain injury. Systematic review of empirical research. Two reviewers independently assessed articles using the methodological quality criteria of Cicerone et al. Data extracted included sample size, diagnosis, intervention information, treatment schedule, assessment methods, and outcome measures. A literature review (PubMed, EMBASE, Ovid, Cochrane, PsychINFO, CINAHL) generated a total of 4931 publications. Twenty-eight studies using computerized cognitive interventions targeting attention and executive functions were included in this review. In 23 studies, significant improvements in attention and executive function subsequent to training were reported; in the remaining 5, promising trends were observed. Preliminary evidence suggests improvements in cognitive function following computerized rehabilitation for acquired brain injury populations including traumatic brain injury and stroke. Further studies are needed to address methodological issues (eg, small sample size, inadequate control groups) and to inform development of guidelines and standardized protocols.
Optically controlled welding system
NASA Technical Reports Server (NTRS)
Gordon, Stephen S. (Inventor)
1989-01-01
An optically controlled welding system (10) wherein a welding torch (12) having through-the-torch viewing capabilities is provided with an optical beam splitter (56) to create a transmitted view and a reflective view of a welding operation. These views are converted to digital signals which are then processed and utilized by a computerized robotic welder (15) to make the welding torch responsive thereto. Other features includes an actively cooled electrode holder (26) which minimizes a blocked portion of the view by virtue of being constructed of a single spoke or arm (28) and a weld pool contour detector (14) comprising a laser beam directed onto the weld pool with the position of specular radiation reflected therefrom being characteristic of a penetrated or unpenetrated condition of the weld pool.
[The use of computer-assisted stabilometry in the diagnosis of craniomandibular disorders].
Palano, D; Molinari, G; Cappelletto, M; Guidetti, G; Vernole, B
1994-01-01
The aim of this study was to evaluate the influence of the cervical region and the stomatognathic system on the balance control. We examined 35 healthy subjects and 201 balance disorder patients; of the 201 patients 60 suffered also from craniomandibular disorders (CMD) and 40 from cervical rachis disease. All cases were tested by computerized stabilometry executed in Romberg position: with closed eyes, retroflexed head and two cotton roles between the dental arches. The results show that cervical rachis disease and stomatognathic dysfunction have a significative influence on the balance control; however, this influence is smaller than that of vestibular disease; moreover, the computer stabilometry allows to measure the degree of ascending or descending correlation between the posture and stomatognathic system.
Davis, Laurie Laughlin; Dodd, Barbara G
2008-01-01
Exposure control research with polytomous item pools has determined that randomization procedures can be very effective for controlling test security in computerized adaptive testing (CAT). The current study investigated the performance of four procedures for controlling item exposure in a CAT under the partial credit model. In addition to a no exposure control baseline condition, the Kingsbury-Zara, modified-within-.10-logits, Sympson-Hetter, and conditional Sympson-Hetter procedures were implemented to control exposure rates. The Kingsbury-Zara and the modified-within-.10-logits procedures were implemented with 3 and 6 item candidate conditions. The results show that the Kingsbury-Zara and modified-within-.10-logits procedures with 6 item candidates performed as well as the conditional Sympson-Hetter in terms of exposure rates, overlap rates, and pool utilization. These two procedures are strongly recommended for use with partial credit CATs due to their simplicity and strength of their results.
Microcomputer keeps watch at Emerald Mine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-04-01
This paper reviews the computerized mine monitoring system set up at the Emerald Mine, SW Pennsylvania, USA. This coal mine has pioneered the automation of many production and safety features and this article covers their work in fire detection and conveyor belt monitoring. A central computer control room can safely watch over the whole underground mining operation using one 25 inch colour monitor. These new data-acquisition systems will lead the way, in the future, to safer move efficient coal mining. Multi-point monitoring of carbon monoxide, heat anomalies, toxic gases and the procedures in conveyor belt operation from start-up to closedown.
High resolution collimator system for X-ray detector
Eberhard, Jeffrey W.; Cain, Dallas E.
1987-01-01
High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.
The data base management system alternative for computing in the human services.
Sircar, S; Schkade, L L; Schoech, D
1983-01-01
The traditional incremental approach to computerization presents substantial problems as systems develop and grow. The Data Base Management System approach to computerization was developed to overcome the problems resulting from implementing computer applications one at a time. The authors describe the applications approach and the alternative Data Base Management System (DBMS) approach through their developmental history, discuss the technology of DBMS components, and consider the implications of choosing the DBMS alternative. Human service managers need an understanding of the DBMS alternative and its applicability to their agency data processing needs. The basis for a conscious selection of computing alternatives is outlined.
Comprehensive Digital Imaging Network Project At Georgetown University Hospital
NASA Astrophysics Data System (ADS)
Mun, Seong K.; Stauffer, Douglas; Zeman, Robert; Benson, Harold; Wang, Paul; Allman, Robert
1987-10-01
The radiology practice is going through rapid changes due to the introduction of state-of-the-art computed based technologies. For the last twenty years we have witnessed the introduction of many new medical diagnostic imaging systems such as x-ray computed tomo-graphy, digital subtraction angiography (DSA), computerized nuclear medicine, single pho-ton emission computed tomography (SPECT), positron emission tomography (PET) and more re-cently, computerized digital radiography and nuclear magnetic resonance imaging (MRI). Other than the imaging systems, there has been a steady introduction of computed based information systems for radiology departments and hospitals.
Experimental on-stream elimination of resonant whirl in a large centrifugal compressor
NASA Technical Reports Server (NTRS)
Bhat, G. I.; Eierman, R. G.
1984-01-01
Resonant whirl condition during operation of a multi-stage centrifugal compressor at higher than anticipated speeds and loads was reported. The condition was diagnosed by a large scale computerized Machinery Condition Monitoring System (MACMOS). This computerized system verified that the predominant subsynchronous whirl frequency locked in on the first resonant frequency of the compressor rotor and did not vary with compressor speed. Compressor stability calculations showed the rotor system had excessive hearing stiffness and inadequate effective damping. An optimum bearing design which was developed to minimize the unbalance response and to maximize the stability threshold is presented.
Nuclear Technology Requires Control by the People, anywhere on Our Planet.
NASA Astrophysics Data System (ADS)
Synek, Miroslav
2000-03-01
------- Human society on our planet, in its historical development, utilizing the knowledge of physics, has reached a powerful technology of nuclear intercontinental ballistic missiles, conceivably controllable through a computerized "push-button". Whenever this technology falls under the control of an irresponsible , miscalculating, or, insane, DICTATOR, with powerful means of a mass-produced nuclear built-up, anywhere on our planet, the very survival of all humanity on our planet could be threatened. --- Therefore, it is a historical urgency that this technology is under the control by a government of the people, by the people and for the people, based on a sufficiently secure system of FREE ELECTIONS, in any country on our planet, wherever and whenever such a threatening possibility exists.
Digital Controller For Acoustic Levitation
NASA Technical Reports Server (NTRS)
Tarver, D. Kent
1989-01-01
Acoustic driver digitally controls sound fields along three axes. Allows computerized acoustic levitation and manipulation of small objects for such purposes as containerless processing and nuclear-fusion power experiments. Also used for controlling motion of vibration-testing tables in three dimensions.
Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients
Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.
2008-01-01
Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982
Pilot study on the feasibility of a computerized speech recognition charting system.
Feldman, C A; Stevens, D
1990-08-01
The objective of this study was to determine the feasibility of developing and using a voice recognition computerized charting system to record dental clinical examination data. More specifically, the study was designed to analyze the time and error differential between the traditional examiner/recorder method (ASSISTANT) and computerized voice recognition method (VOICE). DMFS examinations were performed twice on 20 patients using the traditional ASSISTANT and the VOICE charting system. A statistically significant difference was found when comparing the mean ASSISTANT time of 2.69 min to the VOICE time of 3.72 min (P less than 0.001). No statistically significant difference was found when comparing the mean ASSISTANT recording errors of 0.1 to VOICE recording errors of 0.6 (P = 0.059). 90% of the patients indicated they felt comfortable with the dentist talking to a computer and only 5% of the sample indicated they opposed VOICE. Results from this pilot study indicate that a charting system utilizing voice recognition technology could be considered a viable alternative to traditional examiner/recorder methods of clinical charting.
Rangé, G; Chassaing, S; Marcollet, P; Saint-Étienne, C; Dequenne, P; Goralski, M; Bardiére, P; Beverilli, F; Godillon, L; Sabine, B; Laure, C; Gautier, S; Hakim, R; Albert, F; Angoulvant, D; Grammatico-Guillon, L
2018-05-01
To assess the reliability and low cost of a computerized interventional cardiology (IC) registry to prospectively and systematically collect high-quality data for all consecutive coronary patients referred for coronary angiogram or/and coronary angioplasty. Rigorous clinical practice assessment is a key factor to improve prognosis in IC. A prospective and permanent registry could achieve this goal but, presumably, at high cost and low level of data quality. One multicentric IC registry (CRAC registry), fully integrated to usual coronary activity report software, started in the centre Val-de-Loire (CVL) French region in 2014. Quality assessment of CRAC registry was conducted on five IC CathLab of the CVL region, from January 1st to December 31st 2014. Quality of collected data was evaluated by measuring procedure exhaustivity (comparing with data from hospital information system), data completeness (quality controls) and data consistency (by checking complete medical charts as gold standard). Cost per procedure (global registry operating cost/number of collected procedures) was also estimated. CRAC model provided a high-quality level with 98.2% procedure completeness, 99.6% data completeness and 89% data consistency. The operating cost per procedure was €14.70 ($16.51) for data collection and quality control, including ST-segment elevation myocardial infarction (STEMI) preadmission information and one-year follow-up after angioplasty. This integrated computerized IC registry led to the construction of an exhaustive, reliable and costless database, including all coronary patients entering in participating IC centers in the CVL region. This solution will be developed in other French regions, setting up a national IC database for coronary patients in 2020: France PCI. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Computerized estimation of compatibility of stressors at work and worker's health characteristics.
Susnik, J; Bizjak, B; Cestnik, B
1996-09-01
A system of computerized estimation of compatibility of stressors at work and worker's health characteristics is presented. Each characteristic is defined and scored on a specific scale. Incompatible workplace characteristics as related to worker's characteristics are singled out and offered to the user for an ergonomic solution. Work on the system started in 1987. This paper deals with the system's further development, which involves a larger number of topics, changes of the algorithm and presentation of an applicative case. Comparison of the system's results with those of medical experts shows that the use of the system tends to improve the thoroughness and consistency of incompatibility evaluations and consequently to make working ability assessment more objective.
ERIC Educational Resources Information Center
Ulinski, Don
2013-01-01
Physicians are the influential force in the complex field of patient care delivery. Physicians determine when and where patient healthcare is delivered and affect 80% of the money spent on it. Computerized systems used in the delivery of healthcare information have become an integral part that physicians use to provide patient care. This study…
ERIC Educational Resources Information Center
Brandhorst, W. T.
An analysis of existing computerized data banks in science and technology reveals that nearly half of them involve the storage and retrieval of bibliographic data. Activity in this area has been independent and autonomous. This situation is now giving way to a new environment which involves cooperation, standards, and a rigorous rational analysis…
Assessment of eHealth capabilities and utilization in residential care settings.
Towne, Samuel D; Lee, Shinduk; Li, Yajuan; Smith, Matthew Lee
2016-12-01
The US National Survey of Residential Care Facilities was used to conduct cross-sectional analyses of residential care facilities (n = 2302). Most residential care facilities lacked computerized capabilities for one or more of these capabilities in 2010. Lacking computerized systems supporting electronic health information exchange with pharmacies was associated with non-chain affiliation (p < .05). Lacking electronic health information exchange with physicians was associated with being a small-sized facility (vs large) (p < .05). Lacking computerized capabilities for discharge/transfer summaries was associated with for-profit status (p < .05) and small-sized facilities (p < .05). Lacking computerized capabilities for medical provider information was associated with non-chain affiliation (p < .05), small- or medium-sized facilities (p < .05), and for-profit status (p < .05). Lack of electronic health record was associated with non-chain affiliation (p < .05), small- or medium-sized facilities (p < .05), for-profit status (p < .05), and location in urban areas (p < .05). eHealth disparities exist across residential care facilities. As the older adult population continues to grow, resources must be in place to provide an integrated system of care across multiple settings. © The Author(s) 2015.
Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M
2017-08-01
The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings. Aerosp Med Hum Perform. 2017; 88(8):722-729.
Naval War College Review. Volume 67, Number 3, Summer 2014
2014-01-01
Naval Career, has recently been published by the Press as Newport Paper 41� We wish Barney fair winds and following seas� our next two offerings in...now done�” In goschen’s opinion, “the best way of taking the wind out of the sails of the Big Navy Party in germany is to state frankly that if...and computerization of command and control; expanded use of shipborne helicopters; automation of gunnery and sensor systems; and even the advent of
NASA Technical Reports Server (NTRS)
Gillham, J. K.
1974-01-01
The results are discussed of the on-line interface of the Torsional Braid Analysis experiment to an Hierarchical Computer System for data acquisition, data reduction and control of experimental variables. Some experimental results are demonstrated and the data reduction procedures are outlined. Several modes of presentation of the final computer-reduced data are discussed in an attempt to elucidate possible interrelations between the thermal variation of the rigidity and loss parameters.
Clinical results of computerized tomography-based simulation with laser patient marking.
Ragan, D P; Forman, J D; He, T; Mesina, C F
1996-02-01
Accuracy of a patient treatment portal marking device and computerized tomography (CT) simulation have been clinically tested. A CT-based simulator has been assembled based on a commercial CT scanner. This includes visualization software and a computer-controlled laser drawing device. This laser drawing device is used to transfer the setup, central axis, and/or radiation portals from the CT simulator to the patient for appropriate patient skin marking. A protocol for clinical testing is reported. Twenty-five prospectively, sequentially accessioned patients have been analyzed. The simulation process can be completed in an average time of 62 min. Under many cases, the treatment portals can be designed and the patient marked in one session. Mechanical accuracy of the system was found to be within +/- 1mm. The portal projection accuracy in clinical cases is observed to be better than +/- 1.2 mm. Operating costs are equivalent to the conventional simulation process it replaces. Computed tomography simulation is a clinical accurate substitute for conventional simulation when used with an appropriate patient marking system and digitally reconstructed radiographs. Personnel time spent in CT simulation is equivalent to time in conventional simulation.
Jousimaa, Jukkapekka; Mäkelä, Marjukka; Kunnamo, Ilkka; MacLennan, Graeme; Grimshaw, Jeremy M
2002-01-01
To compare the effects of computerized and paper-based versions of guidelines on recently qualified physicians' consultation practices. Two arm cluster randomized controlled trial. Physicians were randomized to receive computerized or textbook-based versions of the same guidelines for a 4-week study period. Physicians' compliance with guideline recommendations about laboratory, radiological, physical and other examinations, procedures, nonpharmacologic and pharmacologic treatments, physiotherapy, and referrals were measured by case note review. There were 139 recently qualified physicians working in 96 primary healthcare centers in Finland who participated in the study. Data on 4,633 patient encounters were abstracted, of which 3,484 were suitable for further analysis. Physicians' compliance with guidelines was high (over 80% for use of laboratory, radiology, physical examinations, and referrals). There were no significant differences in physicians' consultation practices in any of the measured outcomes between the computerized and textbook group. Guidelines are a useful source of information for recently qualified physicians working in primary care. However, the method of presentation of the guidelines (electronic or paper) does not have an effect on guideline use or their impact on decisions. Other factors should be considered when choosing the method of presentation of guidelines, such as information-seeking time, ease of use during the consultation, ability to update, production costs, and the physician's own preferences.
Weir, Charlene R.; Nebeker, Jonathan J.R.; Hicken, Bret L.; Campo, Rebecca; Drews, Frank; LeBar, Beth
2007-01-01
Objective Computerized Provider Order Entry (CPOE) with electronic documentation, and computerized decision support dramatically changes the information environment of the practicing clinician. Prior work patterns based on paper, verbal exchange, and manual methods are replaced with automated, computerized, and potentially less flexible systems. The objective of this study is to explore the information management strategies that clinicians use in the process of adapting to a CPOE system using cognitive task analysis techniques. Design Observation and semi-structured interviews were conducted with 88 primary-care clinicians at 10 Veterans Administration Medical Centers. Measurements Interviews were taped, transcribed, and extensively analyzed to identify key information management goals, strategies, and tasks. Tasks were aggregated into groups, common components across tasks were clarified, and underlying goals and strategies identified. Results Nearly half of the identified tasks were not fully supported by the available technology. Six core components of tasks were identified. Four meta-cognitive information management goals emerged: 1) Relevance Screening; 2) Ensuring Accuracy; 3) Minimizing memory load; and 4) Negotiating Responsibility. Strategies used to support these goals are presented. Conclusion Users develop a wide array of information management strategies that allow them to successfully adapt to new technology. Supporting the ability of users to develop adaptive strategies to support meta-cognitive goals is a key component of a successful system. PMID:17068345
Applying World Wide Web technology to the study of patients with rare diseases.
de Groen, P C; Barry, J A; Schaller, W J
1998-07-15
Randomized, controlled trials of sporadic diseases are rarely conducted. Recent developments in communication technology, particularly the World Wide Web, allow efficient dissemination and exchange of information. However, software for the identification of patients with a rare disease and subsequent data entry and analysis in a secure Web database are currently not available. To study cholangiocarcinoma, a rare cancer of the bile ducts, we developed a computerized disease tracing system coupled with a database accessible on the Web. The tracing system scans computerized information systems on a daily basis and forwards demographic information on patients with bile duct abnormalities to an electronic mailbox. If informed consent is given, the patient's demographic and preexisting medical information available in medical database servers are electronically forwarded to a UNIX research database. Information from further patient-physician interactions and procedures is also entered into this database. The database is equipped with a Web user interface that allows data entry from various platforms (PC-compatible, Macintosh, and UNIX workstations) anywhere inside or outside our institution. To ensure patient confidentiality and data security, the database includes all security measures required for electronic medical records. The combination of a Web-based disease tracing system and a database has broad applications, particularly for the integration of clinical research within clinical practice and for the coordination of multicenter trials.
Li, Gang; Wang, Zhenhai; Mao, Xinyu; Zhang, Yinghuang; Huo, Xiaoye; Liu, Haixiao; Xu, Shengyong
2016-01-01
Dynamic mapping of an object’s local temperature distribution may offer valuable information for failure analysis, system control and improvement. In this letter we present a computerized measurement system which is equipped with a hybrid, low-noise mechanical-electrical multiplexer for real-time two-dimensional (2D) mapping of surface temperatures. We demonstrate the performance of the system on a device embedded with 32 pieces of built-in Cr-Pt thin-film thermocouples arranged in a 4 × 8 matrix. The system can display a continuous 2D mapping movie of relative temperatures with a time interval around 1 s. This technique may find applications in a variety of practical devices and systems. PMID:27347969
2013-01-01
Objective. This study compared the relationship between computer experience and performance on computerized cognitive tests and a traditional paper-and-pencil cognitive test in a sample of older adults (N = 634). Method. Participants completed computer experience and computer attitudes questionnaires, three computerized cognitive tests (Useful Field of View (UFOV) Test, Road Sign Test, and Stroop task) and a paper-and-pencil cognitive measure (Trail Making Test). Multivariate analysis of covariance was used to examine differences in cognitive performance across the four measures between those with and without computer experience after adjusting for confounding variables. Results. Although computer experience had a significant main effect across all cognitive measures, the effect sizes were similar. After controlling for computer attitudes, the relationship between computer experience and UFOV was fully attenuated. Discussion. Findings suggest that computer experience is not uniquely related to performance on computerized cognitive measures compared with paper-and-pencil measures. Because the relationship between computer experience and UFOV was fully attenuated by computer attitudes, this may imply that motivational factors are more influential to UFOV performance than computer experience. Our findings support the hypothesis that computer use is related to cognitive performance, and this relationship is not stronger for computerized cognitive measures. Implications and directions for future research are provided. PMID:22929395
Reading Comprehension: A Computerized Intervention with Primary-age Poor Readers.
Horne, Joanna Kathryn
2017-05-01
The current study investigates the effectiveness of a computerized reading comprehension programme on the reading accuracy, reading comprehension and reading rate of primary-age poor readers. There is little published literature relating to computerized reading interventions in UK primary schools, and no previous studies have investigated the Comprehension Booster programme. Thirty-eight children (26 boys and 12 girls; aged 6:7 to 11:0) from two schools in East Yorkshire, UK, took part. Half of the participants (the intervention group) undertook the Comprehension Booster programme for a 6-week period, whilst the other half (the control group) continued with their usual teaching. Significant effects of the intervention were found, with increases in reading accuracy and reading comprehension for the intervention group. It is concluded that computerized reading programmes can be effective in improving reading skills, and these are particularly useful for pupils with reading difficulties in disadvantaged areas, where resources are limited and family support in reading is lower. However, such programmes are not a replacement for good teaching, and regular monitoring of children with reading difficulties is required. Further research is necessary to compare the programme used here to other conventional and computerized intervention programmes, using a larger sample. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Feldon, Steven E
2004-01-01
ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764
Roshanov, Pavel S; Misra, Shikha; Gerstein, Hertzel C; Garg, Amit X; Sebaldt, Rolf J; Mackay, Jean A; Weise-Kelly, Lorraine; Navarro, Tamara; Wilczynski, Nancy L; Haynes, R Brian
2011-08-03
The use of computerized clinical decision support systems (CCDSSs) may improve chronic disease management, which requires recurrent visits to multiple health professionals, ongoing disease and treatment monitoring, and patient behavior modification. The objective of this review was to determine if CCDSSs improve the processes of chronic care (such as diagnosis, treatment, and monitoring of disease) and associated patient outcomes (such as effects on biomarkers and clinical exacerbations). We conducted a decision-maker-researcher partnership systematic review. We searched MEDLINE, EMBASE, Ovid's EBM Reviews database, Inspec, and reference lists for potentially eligible articles published up to January 2010. We included randomized controlled trials that compared the use of CCDSSs to usual practice or non-CCDSS controls. Trials were eligible if at least one component of the CCDSS was designed to support chronic disease management. We considered studies 'positive' if they showed a statistically significant improvement in at least 50% of relevant outcomes. Of 55 included trials, 87% (n = 48) measured system impact on the process of care and 52% (n = 25) of those demonstrated statistically significant improvements. Sixty-five percent (36/55) of trials measured impact on, typically, non-major (surrogate) patient outcomes, and 31% (n = 11) of those demonstrated benefits. Factors of interest to decision makers, such as cost, user satisfaction, system interface and feature sets, unique design and deployment characteristics, and effects on user workflow were rarely investigated or reported. A small majority (just over half) of CCDSSs improved care processes in chronic disease management and some improved patient health. Policy makers, healthcare administrators, and practitioners should be aware that the evidence of CCDSS effectiveness is limited, especially with respect to the small number and size of studies measuring patient outcomes.
2011-01-01
Background The use of computerized clinical decision support systems (CCDSSs) may improve chronic disease management, which requires recurrent visits to multiple health professionals, ongoing disease and treatment monitoring, and patient behavior modification. The objective of this review was to determine if CCDSSs improve the processes of chronic care (such as diagnosis, treatment, and monitoring of disease) and associated patient outcomes (such as effects on biomarkers and clinical exacerbations). Methods We conducted a decision-maker-researcher partnership systematic review. We searched MEDLINE, EMBASE, Ovid's EBM Reviews database, Inspec, and reference lists for potentially eligible articles published up to January 2010. We included randomized controlled trials that compared the use of CCDSSs to usual practice or non-CCDSS controls. Trials were eligible if at least one component of the CCDSS was designed to support chronic disease management. We considered studies 'positive' if they showed a statistically significant improvement in at least 50% of relevant outcomes. Results Of 55 included trials, 87% (n = 48) measured system impact on the process of care and 52% (n = 25) of those demonstrated statistically significant improvements. Sixty-five percent (36/55) of trials measured impact on, typically, non-major (surrogate) patient outcomes, and 31% (n = 11) of those demonstrated benefits. Factors of interest to decision makers, such as cost, user satisfaction, system interface and feature sets, unique design and deployment characteristics, and effects on user workflow were rarely investigated or reported. Conclusions A small majority (just over half) of CCDSSs improved care processes in chronic disease management and some improved patient health. Policy makers, healthcare administrators, and practitioners should be aware that the evidence of CCDSS effectiveness is limited, especially with respect to the small number and size of studies measuring patient outcomes. PMID:21824386
Exploring the possibility of modeling a genetic counseling guideline using agile methodology.
Choi, Jeeyae
2013-01-01
Increased demand of genetic counseling services heightened the necessity of a computerized genetic counseling decision support system. In order to develop an effective and efficient computerized system, modeling of genetic counseling guideline is an essential step. Throughout this pilot study, Agile methodology with United Modeling Language (UML) was utilized to model a guideline. 13 tasks and 14 associated elements were extracted. Successfully constructed conceptual class and activity diagrams revealed that Agile methodology with UML was a suitable tool to modeling a genetic counseling guideline.
Acoustic beam control in biomimetic projector via velocity gradient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Xiaowei; Dong, Erqian; Song, Zhongchang
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Acoustic beam control in biomimetic projector via velocity gradient
NASA Astrophysics Data System (ADS)
Gao, Xiaowei; Zhang, Yu; Cao, Wenwu; Dong, Erqian; Song, Zhongchang; Li, Songhai; Tang, Liguo; Zhang, Sai
2016-07-01
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Motorized CPM/CAM physiotherapy device with sliding-mode Fuzzy Neural Network control loop.
Ho, Hung-Jung; Chen, Tien-Chi
2009-11-01
Continuous passive motion (CPM) and controllable active motion (CAM) physiotherapy devices promote rehabilitation of damaged joints. This paper presents a computerized CPM/CAM system that obviates the need for mechanical resistance devices such as springs. The system is controlled by a computer which performs sliding-mode Fuzzy Neural Network (FNN) calculations online. CAM-type resistance force is generated by the active performance of an electric motor which is controlled so as to oppose the motion of the patient's leg. A force sensor under the patient's foot on the device pedal provides data for feedback in a sliding-mode FNN control loop built around the motor. Via an active impedance control feedback system, the controller drives the motor to behave similarly to a damped spring by generating and controlling the amplitude and direction of the pedal force in relation to the patient's leg. Experiments demonstrate the high sensitivity and speed of the device. The PC-based feedback nature of the control loop means that sophisticated auto-adaptable CPM/CAM custom-designed physiotherapy becomes possible. The computer base also allows extensive data recording, data analysis and network-connected remote patient monitoring.
Computerized Measurement of Negative Symptoms in Schizophrenia
Cohen, Alex S.; Alpert, Murray; Nienow, Tasha M.; Dinzeo, Thomas J.; Docherty, Nancy M.
2008-01-01
Accurate measurement of negative symptoms is crucial for understanding and treating schizophrenia. However, current measurement strategies are reliant on subjective symptom rating scales which often have psychometric and practical limitations. Computerized analysis of patients’ speech offers a sophisticated and objective means of evaluating negative symptoms. The present study examined the feasibility and validity of using widely-available acoustic and lexical-analytic software to measure flat affect, alogia and anhedonia (via positive emotion). These measures were examined in their relationships to clinically-rated negative symptoms and social functioning. Natural speech samples were collected and analyzed for 14 patients with clinically-rated flat affect, 46 patients without flat affect and 19 healthy controls. The computer-based inflection and speech rate measures significantly discriminated patients with flat affect from controls, and the computer-based measure of alogia and negative emotion significantly discriminated the flat and non-flat patients. Both the computer and clinical measures of positive emotion/anhedonia corresponded to functioning impairments. The computerized method of assessing negative symptoms offered a number of advantages over the symptom scale-based approach. PMID:17920078
Sequist, Thomas D.; Ayanian, John Z.; Shaykevich, Shimon; Fairchild, David G.; Orav, E. John; Bates, David W.
2008-01-01
BACKGROUND We conducted a cluster randomized controlled trial to examine the effectiveness of computerized decision support (CDS) designed to improve hypertension care and outcomes in a racially diverse sample of primary care patients. METHODS We randomized 2,027 adult patients receiving hypertension care in 14 primary care practices to either 18 months of their physicians receiving CDS for each hypertensive patient or to usual care without computerized support for the control group. We assessed prescribing of guideline-recommended drug therapy and levels of blood pressure control for patients in each group and examined if the effects of the intervention differed by patients’ race/ethnicity using interaction terms. MEASUREMENTS AND MAIN RESULTS Rates of blood pressure control were 42% at baseline and 46% at the outcome visit with no significant differences between groups. After adjustment for patients’ demographic and clinical characteristics, number of prior visits, and levels of baseline blood pressure control, there were no differences between intervention groups in the odds of outcome blood pressure control. The use of CDS to providers significantly improved Joint National Committee (JNC) guideline adherent medication prescribing compared to usual care (7% versus 5%, P < 0.001); the effects of the intervention remained after multivariable adjustment (odds ratio [OR] 1.39 [CI, 1.13–1.72]) and the effects of the intervention did not differ by patients’ race and ethnicity. CONCLUSIONS CDS improved appropriate medication prescribing with no improvement in disparities in care and overall blood pressure control. Future work focusing on improvement of these interventions and the study of other practical interventions to reduce disparities in hypertension-related outcomes is needed. PMID:18373141
Parasuraman, Raja; de Visser, Ewart; Lin, Ming-Kuan; Greenwood, Pamela M.
2012-01-01
Computerized aiding systems can assist human decision makers in complex tasks but can impair performance when they provide incorrect advice that humans erroneously follow, a phenomenon known as “automation bias.” The extent to which people exhibit automation bias varies significantly and may reflect inter-individual variation in the capacity of working memory and the efficiency of executive function, both of which are highly heritable and under dopaminergic and noradrenergic control in prefrontal cortex. The dopamine beta hydroxylase (DBH) gene is thought to regulate the differential availability of dopamine and norepinephrine in prefrontal cortex. We therefore examined decision-making performance under imperfect computer aiding in 100 participants performing a simulated command and control task. Based on two single nucleotide polymorphism (SNPs) of the DBH gene, −1041 C/T (rs1611115) and 444 G/A (rs1108580), participants were divided into groups of low and high DBH enzyme activity, where low enzyme activity is associated with greater dopamine relative to norepinephrine levels in cortex. Compared to those in the high DBH enzyme activity group, individuals in the low DBH enzyme activity group were more accurate and speedier in their decisions when incorrect advice was given and verified automation recommendations more frequently. These results indicate that a gene that regulates relative prefrontal cortex dopamine availability, DBH, can identify those individuals who are less susceptible to bias in using computerized decision-aiding systems. PMID:22761865
Cerruto, Carmen; Di Vece, Luca; Doldo, Tiziana; Giovannetti, Agostino; Polimeni, Antonella; Goracci, Cecilia
2012-01-01
To assess the applicability of a computerized method to measure on digital photographs the changes in head and scapular posture following rapid palatal expansion (RPE) treatment. Randomized controlled trial. Twenty-three children (age 9.2 +/- 70.88 years) diagnosed with maxillary constriction were randomly divided into two groups: 1. Study group (n = 12): patients receiving RPE treatment; 2. Untreated controls (n = 11). Postural measurements were taken on frontal, lateral, and dorsal views of each subject. In the study group measurements were taken at T0 (the day orthodontic records were taken), T1 (end of RPE active phase), and T2 (RPE removal). In controls the same observations were conducted at T0 and T1(98.18 +/- 36.01 days after T0). Measurements were statistically analyzed (Intraclass Correlation Coefficient, t-tests, Signed Rank test, One-Way Repeated Measures Analysis of Variance, Tukey test; p < 0.05). In the study group a significant reduction in forward head posture (FHP) occurred between T0 and T1. Forward shoulder posture (FSP) decreased significantly between T1 and T2. At T1 treated patients exhibited significantly lower values of the measurements indicating FHP and FSP than controls. Changes in head and scapular posture following RPE treatment can be documented with computerized measurements on digital photographs.
Bortolotti, Laura; Cobianchi, Mario; Breda, Tatiana; Favero, Laura; Ruocco, Luigi; Marangon, Stefano
2013-10-01
After 20 years of absence, rabies re-emerged in wild animals in north-eastern Italy in October 2008. Besides measures undertaken to fight the spread of infection in wildlife, vaccination against rabies was made compulsory for dogs living in the risk area. In the last 15 years, the veterinary authorities have focused on implementing computerized data collection systems in animal health, to serve as working tools for epidemiological surveillance activities and emergencies management. The prerequisite for implementing any data collection system is knowledge of the animal population. This also applies to the Canine Registry Data Bank, in which data on dogs and their movements, together with personal data on each owner and keeper, have been stored since 2003. The management information system has been updated and specific functions have been integrated in order to support the activity of both the veterinary services and the veterinary practitioners involved in the dog vaccination program. Vaccination became voluntary in February 2013. This paper describes implementation of the software and organization of data gathering, highlighting the benefits of computerized data compared to previously used paper-based data collection systems. The new functions, designed to centralize collection of uniform, updated vaccination data, have led to more efficient organization and better control of the vaccination plan. Automated information processing allowed vaccination operations to be supervised, incurred costs to be calculated, and vaccination coverage of the dog population to be monitored during the 3 years of compulsory vaccination.
NASA Astrophysics Data System (ADS)
Arkadov, G. V.; Zhukavin, A. P.; Kroshilin, A. E.; Parshikov, I. A.; Solov'ev, S. L.; Shishov, A. V.
2014-10-01
The article describes the "Virtual Digital VVER-Based Nuclear Power Plant" computerized system comprising a totality of verified initial data (sets of input data for a model intended for describing the behavior of nuclear power plant (NPP) systems in design and emergency modes of their operation) and a unified system of new-generation computation codes intended for carrying out coordinated computation of the variety of physical processes in the reactor core and NPP equipment. Experiments with the demonstration version of the "Virtual Digital VVER-Based NPP" computerized system has shown that it is in principle possible to set up a unified system of computation codes in a common software environment for carrying out interconnected calculations of various physical phenomena at NPPs constructed according to the standard AES-2006 project. With the full-scale version of the "Virtual Digital VVER-Based NPP" computerized system put in operation, the concerned engineering, design, construction, and operating organizations will have access to all necessary information relating to the NPP power unit project throughout its entire lifecycle. The domestically developed commercial-grade software product set to operate as an independently operating application to the project will bring about additional competitive advantages in the modern market of nuclear power technologies.
Opportunities for development of advanced large cargo aircraft
NASA Technical Reports Server (NTRS)
Whitehead, A. H., Jr.
1976-01-01
A critical review of the history, current state of the art, and future prospects for cargo aircraft systems indicates that three of the major advantages of air cargo are rapid delivery, ability to bridge geographical boundaries, and capability to provide a flexible market response. Foreseeable advances in large aircraft development offer even greater profit potential by increasing the payload ton-miles per pound of fuel. Intermodal containers and handling systems and computerized control and billing may be key ingredients. Details of a NASA program for large aircraft systems technology are outlined, which includes systems studies, research and technology investigations, and determination of the need for critical flight experiments. Innovative advanced technologies and configuration concepts are discussed. Numerous illustrations supplement the text.
NASA Technical Reports Server (NTRS)
Schaub, J. D.; Koenig, S. C.; Schroeder, M. J.; Ewert, D. L.; Drew, G. A.; Swope, R. D.; Convertino, V. A. (Principal Investigator)
1999-01-01
An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.
Evaluation of Spontaneous Spinal Cerebrospinal Fluid Leaks Disease by Computerized Image Processing.
Yıldırım, Mustafa S; Kara, Sadık; Albayram, Mehmet S; Okkesim, Şükrü
2016-05-17
Spontaneous Spinal Cerebrospinal Fluid Leaks (SSCFL) is a disease based on tears on the dura mater. Due to widespread symptoms and low frequency of the disease, diagnosis is problematic. Diagnostic lumbar puncture is commonly used for diagnosing SSCFL, though it is invasive and may cause pain, inflammation or new leakages. T2-weighted MR imaging is also used for diagnosis; however, the literature on T2-weighted MRI states that findings for diagnosis of SSCFL could be erroneous when differentiating the diseased and control. One another technique for diagnosis is CT-myelography, but this has been suggested to be less successful than T2-weighted MRI and it needs an initial lumbar puncture. This study aimed to develop an objective, computerized numerical analysis method using noninvasive routine Magnetic Resonance Images that can be used in the evaluation and diagnosis of SSCFL disease. Brain boundaries were automatically detected using methods of mathematical morphology, and a distance transform was employed. According to normalized distances, average densities of certain sites were proportioned and a numerical criterion related to cerebrospinal fluid distribution was calculated. The developed method was able to differentiate between 14 patients and 14 control subjects significantly with p = 0.0088 and d = 0.958. Also, the pre and post-treatment MRI of four patients was obtained and analyzed. The results were differentiated statistically (p = 0.0320, d = 0.853). An original, noninvasive and objective diagnostic test based on computerized image processing has been developed for evaluation of SSCFL. To our knowledge, this is the first computerized image processing method for evaluation of the disease. Discrimination between patients and controls shows the validity of the method. Also, post-treatment changes observed in four patients support this verdict.
Macatee, Richard J; Cougle, Jesse R
2015-09-01
A growing body of research has linked high distress intolerance (DI) to obsessions, but not other OCD symptom domains. However, existing research is correlational. Experimental studies are needed, but brief methods for reducing DI are lacking. To address these gaps in the literature, a brief, computerized intervention aimed at reducing DI was developed to determine if changing DI affected obsessional phenomena. Individuals reporting high DI were randomized to a treatment or waitlist control group (N = 53). Individuals in the treatment group received the DI treatment (i.e., a 2 h computerized intervention) over two weeks, and then underwent a post-assessment in which DI and obsession-relevant phenomena were measured. Individuals in the control group only received the post-assessment. Analyses revealed a greater reduction in self-reported DI on one measure and smaller decreases in behavioral DI in the intervention condition relative to the waitlist condition, as well as lower in-vivo urges to neutralize an intrusive thought; however, anxious reactivity to the intrusion and neutralization behavior were not affected. Further, bootstrapping analyses revealed that reductions in DI mediated the effect of the intervention on neutralization urges. A clinical sample and placebo control condition were not used. These results provide experimental evidence for the role of DI in obsessional phenomena, specifically in affecting urges to neutralize intrusions, findings consistent with negative reinforcement models of DI. Further, results revealed that DI can be reduced with a brief, computerized intervention, which has important implications for future experimental research and treatment development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mozaffar, Hajar; Williams, Robin; Cresswell, Kathrin; Morrison, Zoe; Bates, David W; Sheikh, Aziz
2016-03-01
To understand the evolving market of commercial off-the-shelf Computerized Physician Order Entry (CPOE) and Computerized Decision Support (CDS) applications and its effects on their uptake and implementation in English hospitals. Although CPOE and CDS vendors have been quick to enter the English market, uptake has been slow and uneven. To investigate this, the authors undertook qualitative ethnography of vendors and adopters of hospital CPOE/CDS systems in England. The authors collected data from semi-structured interviews with 11 individuals from 4 vendors, including the 2 most entrenched suppliers, and 6 adopter hospitals, and 21 h of ethnographic observation of 2 user groups, and 1 vendor event. The research and analysis was informed by insights from studies of the evolution of technology fields and the emergence of generic COTS enterprise solutions. Four key themes emerged: (1) adoption of systems that had been developed outside of England, (2) vendors' configuration and customization strategies, (3) localized adopter practices vs generic systems, and (4) unrealistic adopter demands. Evidence for our over-arching finding concerning the current immaturity of the market was derived from vendors' strategies, adopters' reactions to the technology, and policy makers' incomplete insights. The CPOE/CDS market in England is still in an emergent phase. The rapid entrance of diverse products, triggered by federal policy initiatives, has resulted in premature adoption of systems that do not yet adequately meet the needs of hospitals. Vendors and adopters lacked understanding of how to design and implement generic solutions to meet diverse user needs. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reproducibility of ad libitum energy intake with the use of a computerized vending machine system123
Votruba, Susanne B; Franks, Paul W; Krakoff, Jonathan; Salbe, Arline D
2010-01-01
Background: Accurate assessment of energy intake is difficult but critical for the evaluation of eating behavior and intervention effects. Consequently, methods to assess ad libitum energy intake under controlled conditions have been developed. Objective: Our objective was to evaluate the reproducibility of ad libitum energy intake with the use of a computerized vending machine system. Design: Twelve individuals (mean ± SD: 36 ± 8 y old; 41 ± 8% body fat) consumed a weight-maintaining diet for 3 d; subsequently, they self-selected all food with the use of a computerized vending machine system for an additional 3 d. Mean daily energy intake was calculated from the actual weight of foods consumed and expressed as a percentage of weight-maintenance energy needs (%WMEN). Subjects repeated the study multiple times during 2 y. The within-person reproducibility of energy intake was determined through the calculation of the intraclass correlation coefficients (ICCs) between visits. Results: Daily energy intake for all subjects was 5020 ± 1753 kcal during visit 1 and 4855 ± 1615 kcal during visit 2. There were no significant associations between energy intake and body weight, body mass index, or percentage body fat while subjects used the vending machines, which indicates that intake was not driven by body size or need. Despite overconsumption (%WMEN = 181 ± 57%), the reproducibility of intake between visits, whether expressed as daily energy intake (ICC = 0.90), %WMEN (ICC = 0.86), weight of food consumed (ICC = 0.87), or fat intake (g/d; ICC = 0.87), was highly significant (P < 0.0001). Conclusion: Although ad libitum energy intake exceeded %WMEN, the within-person reliability of this intake across multiple visits was high, which makes this a reproducible method for the measurement of ad libitum intake in subjects who reside in a research unit. This trial was registered at clinicaltrials.gov as NCT00342732. PMID:19923376
Tanihara, Shinichi
2015-01-01
Uncoded diagnoses in health insurance claims (HICs) may introduce bias into Japanese health statistics dependent on computerized HICs. This study's aim was to identify the causes and characteristics of uncoded diagnoses. Uncoded diagnoses from computerized HICs (outpatient, inpatient, and the diagnosis procedure-combination per-diem payment system [DPC/PDPS]) submitted to the National Health Insurance Organization of Kumamoto Prefecture in May 2010 were analyzed. The text documentation accompanying the uncoded diagnoses was used to classify diagnoses in accordance with the International Classification of Diseases-10 (ICD-10). The text documentation was also classified into four categories using the standard descriptions of diagnoses defined in the master files of the computerized HIC system: 1) standard descriptions of diagnoses, 2) standard descriptions with a modifier, 3) non-standard descriptions of diagnoses, and 4) unclassifiable text documentation. Using these classifications, the proportions of uncoded diagnoses by ICD-10 disease category were calculated. Of the uncoded diagnoses analyzed (n = 363 753), non-standard descriptions of diagnoses for outpatient, inpatient, and DPC/PDPS HICs comprised 12.1%, 14.6%, and 1.0% of uncoded diagnoses, respectively. The proportion of uncoded diagnoses with standard descriptions with a modifier for Diseases of the eye and adnexa was significantly higher than the overall proportion of uncoded diagnoses among every HIC type. The pattern of uncoded diagnoses differed by HIC type and disease category. Evaluating the proportion of uncoded diagnoses in all medical facilities and developing effective coding methods for diagnoses with modifiers, prefixes, and suffixes should reduce number of uncoded diagnoses in computerized HICs and improve the quality of HIC databases.
Physics Leads to Free Elections in the Nuclear Age.
NASA Astrophysics Data System (ADS)
Synek, Miroslav
2001-10-01
------------- Complex historical development on our planet, utilizing the knowledge of physics, has reached a powerful technology of nuclear intercontinental missiles, conceivably controllable through a computerized "push-button". Whenever this technology falls under the control of an irresponsible, miscalculating, or, insane dictator, with sufficiently powerful means of a huge, mass-produced, nuclear-missile built-up, anywhere on our planet, the very survival of all humanity on our planet could be threatened. Therefore, it is a historical urgency that this technology be under the control by a government of the people, by the people and for the people, based on a sufficiently reliable system of free elections, in any country on our planet, wherever and whenever a total nuclear holocaust could originate.
The computerized OMAHA system in microsoft office excel.
Lai, Xiaobin; Wong, Frances K Y; Zhang, Peiqiang; Leung, Carenx W Y; Lee, Lai H; Wong, Jessica S Y; Lo, Yim F; Ching, Shirley S Y
2014-01-01
The OMAHA System was adopted as the documentation system in an interventional study. To systematically record client care and facilitate data analysis, two Office Excel files were developed. The first Excel file (File A) was designed to record problems, care procedure, and outcomes for individual clients according to the OMAHA System. It was used by the intervention nurses in the study. The second Excel file (File B) was the summary of all clients that had been automatically extracted from File A. Data in File B can be analyzed directly in Excel or imported in PASW for further analysis. Both files have four parts to record basic information and the three parts of the OMAHA System. The computerized OMAHA System simplified the documentation procedure and facilitated the management and analysis of data.
Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda
2011-03-01
We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an adequate retrograde cavity depth is prepared, variation in the root-end cutting angle does not necessarily cause any difference in microleakage. Copyright © 2011 Mosby, Inc. All rights reserved.
Impact of Hospital Information Systems on Emergency Patient Processing
Rusnak, James E.
1981-01-01
The Emergency Department offers the Hospital Information System's designer some unique problems to solve in the operational areas of patient registration, order entry, charge recording, and treatment processing. In a number of instances, Hospital Information Systems implementers have encountered serious difficulties in trying to design system components to support the requirements of the Emergency Services Department's operations. Washington Hospital has developed a very effective system for Emergency Services. The system's features are designed to meet the special requirements of the department and to maximize the use of the data captured by the Hospital Information System. The system supports accurate and timely charging for services. The treatment of the patient has been dramatically improved through the use of a computerized order processing and control. The installed systems resulted in a higher quality of care and cost effective operations.
Sixou, Jean-Louis; Marie-Cousin, Alexia; Huet, Adeline; Hingant, Bernard; Robert, Jean-Claude
2009-09-01
Intraosseous (IO) anaesthesia has been shown to be effective in children. However, the pain associated with anaesthetic injections, and its acceptance by children, have never been studied. The aim of this study was to assess the pain associated with the IO injection of 4% articaine with 1 : 200 000 epinephrine using the computerized QuickSleeper' system in a population of children and adolescents. IO anaesthesia was performed on patients aged 10.4 +/- 2.6 years of age. The patients assessed their pain on a faces pain scale (FPS) and on a visual analogue scale (VAS). The operators were also asked to assess signs of patient pain/discomfort. No pain or mild discomfort was reported by, respectively, 81.8% (FPS) and 83.9% (VAS) of the patients. Some 58.9% of children with previous experience of dental anaesthesia reported that computerized IO anaesthesia was more comfortable than traditional infiltration methods. Operators noted signs of discomfort during penetration and injection in 18.3% and 25.3% of the patients, respectively. This study showed that the majority of children reported no pain or mild pain when anaesthetic was administered by computerized needle rotation and solution deposition. This technique holds promise for use by trained paediatric dentists.
Cost accounting, management control, and planning in health care.
Siegrist, R B; Blish, C S
1988-02-01
Advantages and pharmacy applications of computerized hospital management-control and planning systems are described. Hospitals must define their product lines; patient cases, not tests or procedures, are the end product. Management involves operational control, management control, and strategic planning. Operational control deals with day-to-day management on the task level. Management control involves ensuring that managers use resources effectively and efficiently to accomplish the organization's objectives. Management control includes both control of unit costs of intermediate products, which are procedures and services used to treat patients and are managed by hospital department heads, and control of intermediate product use per case (managed by the clinician). Information from the operation and management levels feeds into the strategic plan; conversely, the management level controls the plan and the operational level carries it out. In the system developed at New England Medical Center, Boston, Massachusetts, the intermediate product-management system enables managers to identify intermediate products, develop standard costs, simulate changes in departmental costs, and perform variance analysis. The end-product management system creates a patient-level data-base, identifies end products (patient-care groupings), develops standard resource protocols, models alternative assumptions, performs variance analysis, and provides concurrent reporting. Examples are given of pharmacy managers' use of such systems to answer questions in the areas of product costing, product pricing, variance analysis, productivity monitoring, flexible budgeting, modeling and planning, and comparative analysis.(ABSTRACT TRUNCATED AT 250 WORDS)
Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent
2016-09-01
To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.
Demiris, A M; Meinzer, H P
1997-01-01
Whether or not a computerized system enhances the conditions of work in the application domain, very much demands on the user interface. Graphical user interfaces seem to attract the interest of the users but mostly ignore some basic rules of visual information processing thus leading to systems which are difficult to use, lowering productivity and increasing working stress (cognitive and work load). In this work we present some fundamental ergonomic considerations and their application to the medical image processing and archiving domain. We introduce the extensions to an existing concept needed to control and guide the development of GUIs with respect to domain specific ergonomics. The suggested concept, called Model-View-Controller Constraints (MVCC), can be used to programmatically implement ergonomic constraints, and thus has some advantages over written style guides. We conclude with the presentation of existing norms and methods to evaluate user interfaces.
Cognitive features of psychotic states arising in late life (late paraphrenia).
Almeida, O P; Howard, R J; Levy, R; David, A S; Morris, R G; Sahakian, B J
1995-07-01
The cognitive performance of 47 elderly psychotic patients with onset of symptoms in late life (late paraphrenia) was compared to that of 33 controls matched for age, sex, ethnic origin, number of years of education, and pre-morbid IQ as measured by the NART. Neuropsychological indices of general cognitive functioning (MMSE, CAMCOG, WAIS-R verbal and performance scores) showed that patients were performing the tasks at a significantly lower level than controls. Patients also showed a trend to have a lower span capacity than controls, particularly at the spatial span subtest. There was no obvious impairment of learning as measured by the digit and spatial recurring span tasks nor of simultaneous matching-to-sample ability. However, patients' performance on a delayed-matching-to-sample procedure was significantly worse than that of controls. In addition, patients performed worse than controls on the Recognition Memory Test for Faces, but not for Words. Finally, the performance of patients on tests assessing executive functioning (Verbal Fluency Test, Computerized Extra and Intra-Dimensional Shift Task, Computerized Spatial Working Memory Task, and Computerized Tower of London Task) was consistently worse than that of controls. These results suggest that psychotic states arising in late life are predominantly associated with a decline on measures of general cognitive ability and executive functioning. The neuropsychological meaning of these findings is discussed in the light of cognitive models of psychotic symptoms, as well as of schizophrenia and dementia research. We concluded that the lack of a clear pattern of impairment among these patients may be the result of their clinical and cognitive diversity.
Peretti, Charles-Siegfried; Peretti, Charles Roger; Kozora, Elizabeth; Papathanassiou, Dimitri; Chouinard, Virginie-Anne; Chouinard, Guy
2012-01-01
Systemic lupus erythematosus (SLE) is known to induce psychiatric disorders, from psychoses to maladaptive coping. Brain autoantibodies were proposed to explain SLE neuropsychiatric disorders and found to be elevated before the onset of clinical symptoms. We assessed cognition in Caucasian SLE women with elevated autoantibodies without overt neuropsychiatric syndromes, in conjunction with single photon emission computerized tomography (SPECT). 31 women meeting SLE criteria of the American College of Rheumatology (ACR) were included. Patients who met the ACR neuropsychiatric definition were excluded. Matched controls were 23 healthy women from the Champagne-Ardenne region, France. Participants completed neuropsychological and autoantibodies measurements, and 19 completed SPECT. 61% (19/31) of women with SLE and 53% (9/17) of those with normal SPECT had significant global cognitive impairment defined as 4 T-scores <40 in cognitive tests, compared to 0% (0/23) of controls. SLE women also had significantly greater cognitive dysfunction (mean T-score) on the Wechsler Adult Intelligence Scale (WAIS) visual backspan, Trail Making Test A and B, WAIS Digit Symbol Substitution Test and Stroop Interference, compared to controls. Elevated antinuclear antibody correlated with impairment in the WAIS visual span, WAIS visual backspan, and cancellation task; elevated anti-double-stranded DNA antibody and anticardiolipin correlated respectively with impairment in the Trail Making Test A and WAIS auditive backspan. Two SLE women had abnormal SPECT. A high prevalence of cognitive deficits was found in Caucasian SLE women compared to normal women, which included impairment in cognitive domains important for daily activities. Elevated autoantibodies tended to correlate with cognitive dysfunction. Copyright © 2012 S. Karger AG, Basel.
Clinical and computerized evaluation in study of temporo-mandibular joint intracapsular disease.
Ciavarella, D; Mastrovincenzo, M; Sabatucci, A; Parziale, V; Granatelli, F; Violante, F; Bossù, M; Lo Muzio, L; Chimenti, C
2010-03-01
In this work authors show a diagnostic criteria in study of TMID: neuro occlusal clinical evaluation (NOE), T-Scan 2 system and surface electromyography (sEMG). Nine patients 25-30 years old with TMID problem and 9 healthy group control have been selected and examined. On each patients it has been performed NOE, T-Scan and sEMG test. NOE has been calculated on each patient photos lateral mandibular excursion angle called: masticatory functional angle (AFM). T-Scan System is a computerized occlusal analyzer that provide in-depth understanding of the overall balance of the occlusion. At the same time of T-Scan record sEMG tests, in resting position and in maximum clench, have been performed. In healthy control there were no AFM difference. In no healthy group there were difference between the two AFM greater than 6 degrees. T-Scan COF showed how in healthy group control there was never a difference of COF greater than 5%. In no healthy group the difference were greater than 5% P<0.05. T-scan showed difference of time force in maximum intercuspidation (MIFT) in healthy respect TMID patients. In healthy patients MIFT was higher than TMID patients P<0.05. sEMG test showed in non healthy group a great asymmetrical activation of masseter (MM). MM activation were greater on side affected by joint sound than the balance side P<0.001. sEMG show how in TMID patients maximum masseter activation is always lower than maximum masseter activation of healthy subjects P<0.001. Neuro occlusal clinical evaluation (NOE) in TMID patients is supported by instrumental evaluation.
NASA Technical Reports Server (NTRS)
Seldner, K.
1976-01-01
The development of control systems for jet engines requires a real-time computer simulation. The simulation provides an effective tool for evaluating control concepts and problem areas prior to actual engine testing. The development and use of a real-time simulation of the Pratt and Whitney F100-PW100 turbofan engine is described. The simulation was used in a multi-variable optimal controls research program using linear quadratic regulator theory. The simulation is used to generate linear engine models at selected operating points and evaluate the control algorithm. To reduce the complexity of the design, it is desirable to reduce the order of the linear model. A technique to reduce the order of the model; is discussed. Selected results between high and low order models are compared. The LQR control algorithms can be programmed on digital computer. This computer will control the engine simulation over the desired flight envelope.
El.Mahalli, Azza; El-Khafif, Sahar H.; Yamani, Wid
2016-01-01
The pharmacy information system is one of the central pillars of a hospital information system. This research evaluated a pharmacy information system according to six aspects of the medication process in three hospitals in Eastern Province, Saudi Arabia. System administrators were interviewed to determine availability of functionalities. Then, system users within the hospital were targeted to evaluate their level of usage of these functionalities. The study was cross-sectional. Two structured surveys were designed. The overall response rate of hospital users was 31.7 percent. In all three hospitals studied, the electronic health record is hybrid, implementation has been completed and the system is running, and the systems have computerized provider order entry and clinical decision support. Also, the pharmacy information systems are integrated with the electronic health record, and computerized provider order entry and almost all prescribing and transcription functionalities are available; however, drug dispensing is a mostly manual process. However, the study hospitals do not use barcode-assisted medication administration systems to verify patient identity and electronically check dose administration, and none of them have computerized adverse drug event monitoring that uses the electronic health record. The numbers of users who used different functionalities most or all of the time was generally low. The highest frequency of utilization was for patient administration records (56.8 percent), and the lowest was for linkage of the pharmacy information system to pharmacy stock (9.1 percent). Encouraging users to use different functionalities was highly recommended. PMID:26903780
El Mahalli, Azza; El-Khafif, Sahar H; Yamani, Wid
2016-01-01
The pharmacy information system is one of the central pillars of a hospital information system. This research evaluated a pharmacy information system according to six aspects of the medication process in three hospitals in Eastern Province, Saudi Arabia. System administrators were interviewed to determine availability of functionalities. Then, system users within the hospital were targeted to evaluate their level of usage of these functionalities. The study was cross-sectional. Two structured surveys were designed. The overall response rate of hospital users was 31.7 percent. In all three hospitals studied, the electronic health record is hybrid, implementation has been completed and the system is running, and the systems have computerized provider order entry and clinical decision support. Also, the pharmacy information systems are integrated with the electronic health record, and computerized provider order entry and almost all prescribing and transcription functionalities are available; however, drug dispensing is a mostly manual process. However, the study hospitals do not use barcode-assisted medication administration systems to verify patient identity and electronically check dose administration, and none of them have computerized adverse drug event monitoring that uses the electronic health record. The numbers of users who used different functionalities most or all of the time was generally low. The highest frequency of utilization was for patient administration records (56.8 percent), and the lowest was for linkage of the pharmacy information system to pharmacy stock (9.1 percent). Encouraging users to use different functionalities was highly recommended.
Ferreira, F J O; Crispim, V R; Silva, A X
2010-06-01
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials. Copyright 2010 Elsevier Ltd. All rights reserved.
Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation
Sklarin, Nancy T.; Granovsky, Svetlana; O'Reilly, Eileen M.; Zelenetz, Andrew D.
2011-01-01
Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years. PMID:22043182
Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation.
Sklarin, Nancy T; Granovsky, Svetlana; O'Reilly, Eileen M; Zelenetz, Andrew D
2011-07-01
Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years.
NASA Technical Reports Server (NTRS)
1990-01-01
Vadeko International, Inc., Mississauga, Ontario developed for the Canadian National Railways (CN) the Robotic Paint Application System. The robotic paint shop has two parallel paint booths, allowing simultaneous painting of two hopper cars. Each booth has three robots, two that move along wall-mounted rails to spray-paint the exterior, a third that is lowered through a hatch in the railcar's top to paint the interior. A fully computerized system controls the movement of the robots and the painting process. The robots can do in four hours a job that formerly took 32 hours. The robotic system applies a more thorough coating and CN expects that will double the useful life of its hoppers and improve cost efficiency. Human painters no longer have to handle the difficult and hazardous job. CN paint shop employees have been retrained to operate the computer system that controls the robots. In addition to large scale robotic systems, Vadeko International is engaged in such other areas of technology as flexible automation, nuclear maintenance, underwater vehicles, thin film deposition and wide band monitoring.
Energy Theft in the Advanced Metering Infrastructure
NASA Astrophysics Data System (ADS)
McLaughlin, Stephen; Podkuiko, Dmitry; McDaniel, Patrick
Global energy generation and delivery systems are transitioning to a new computerized "smart grid". One of the principle components of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters with computerized systems that report usage over digital communication interfaces, e.g., phone lines. However, with this infrastructure comes new risk. In this paper, we consider adversary means of defrauding the electrical grid by manipulating AMI systems. We document the methods adversaries will use to attempt to manipulate energy usage data, and validate the viability of these attacks by performing penetration testing on commodity devices. Through these activities, we demonstrate that not only is theft still possible in AMI systems, but that current AMI devices introduce a myriad of new vectors for achieving it.
77 FR 25710 - Agency Information Collection Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-01
... Accident/Incident Reporting System (CAIRS); Occurrence Reporting and Processing System (ORPS); Noncompliance Tracking System (NTS); Radiation Exposure Monitoring System (REMS); Annual Fire Protection Summary... following additional authorities: Computerized Accident/Incident Reporting System (CAIRS): DOE Order 231.1B...
Computerized provider order entry in the clinical laboratory
Baron, Jason M.; Dighe, Anand S.
2011-01-01
Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891
Lemke, John; Sardariani, Edmond; Phipps, Joseph Bradley; Patel, Niki; Itri, Loretta M; Caravelli, James; Viscusi, Eugene R
2016-09-01
Fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS(®)) is a patient-controlled analgesia system used for the management of acute postoperative pain, designed to be utilized in a hospital setting. The objective of the two studies was to determine if fentanyl ITS could be safely used with X-rays, computerized tomography (CT) scans and radiofrequency identification (RFID) devices. The ITS system has two components: controller and drug unit; the studies utilized ITS systems without fentanyl, referred to as the ITS Placebo system. The first study evaluated the effect of X-radiation on the operation of an ITS Placebo system. Five ITS Placebo systems were exposed to X-rays (20 and 200 mSv total radiation dose-the 200 mSv radiation dose represents a tenfold higher exposure than in clinical practice) while operating in the Ready Mode and five were exposed while operating in the Dose Mode. The second study evaluated the effect of RFID (worst-case scenario of direct contact with an RFID transmitter) on the operation of an ITS Placebo system. During these tests, observations of the user interface and measurements of output voltage confirmed proper function throughout all operational modes (Ready Mode, Dose Mode, End-of-Use Mode, and End-of-Life Mode). The ITS Placebo system met all specifications and no functional anomalies were observed during and following X-ray exposure at two radiation dose levels or exposure at six different combinations of RFID frequencies and field strengths. The performance of the ITS system was unaffected by X-ray exposure levels well beyond those associated with diagnostic X-rays and CT scans, and by exposure to radiofrequency field strengths typically generated by RFID devices. These results provide added confidence to clinicians that the fentanyl ITS system does not need to be removed during diagnostic X-rays and CT scans and can also be utilized in close proximity to RFID devices. The studies and writing of this manuscript were supported financially by The Medicines Company.
NASA Technical Reports Server (NTRS)
Guillet, J. E.
1984-01-01
A reaction kinetics based model of the photodegradation process, which measures all important rate constants, and a computerized model capable of predicting the photodegradation rate and failure modes of a 30 year period, were developed. It is shown that the computerized photodegradation model for polyethylene correctly predicts failure of ELVAX 15 and cross linked ELVAX 150 on outdoor exposure. It is indicated that cross linking ethylene vinyl acetate (EVA) does not significantly change its degradation rate. It is shown that the effect of the stabilizer package is approximately equivalent on both polymers. The computerized model indicates that peroxide decomposers and UV absorbers are the most effective stabilizers. It is found that a combination of UV absorbers and a hindered amine light stabilizer (HALS) is the most effective stabilizer system.
Machine Shop. Module 8: CNC (Computerized Numerical Control). Instructor's Guide.
ERIC Educational Resources Information Center
Crosswhite, Dwight
This document consists of materials for a five-unit course on the following topics: (1) safety guidelines; (2) coordinates and dimensions; (3) numerical control math; (4) programming for numerical control machines; and (5) setting and operating the numerical control machine. The instructor's guide begins with a list of competencies covered in the…
Flexible distributed architecture for semiconductor process control and experimentation
NASA Astrophysics Data System (ADS)
Gower, Aaron E.; Boning, Duane S.; McIlrath, Michael B.
1997-01-01
Semiconductor fabrication requires an increasingly expensive and integrated set of tightly controlled processes, driving the need for a fabrication facility with fully computerized, networked processing equipment. We describe an integrated, open system architecture enabling distributed experimentation and process control for plasma etching. The system was developed at MIT's Microsystems Technology Laboratories and employs in-situ CCD interferometry based analysis in the sensor-feedback control of an Applied Materials Precision 5000 Plasma Etcher (AME5000). Our system supports accelerated, advanced research involving feedback control algorithms, and includes a distributed interface that utilizes the internet to make these fabrication capabilities available to remote users. The system architecture is both distributed and modular: specific implementation of any one task does not restrict the implementation of another. The low level architectural components include a host controller that communicates with the AME5000 equipment via SECS-II, and a host controller for the acquisition and analysis of the CCD sensor images. A cell controller (CC) manages communications between these equipment and sensor controllers. The CC is also responsible for process control decisions; algorithmic controllers may be integrated locally or via remote communications. Finally, a system server images connections from internet/intranet (web) based clients and uses a direct link with the CC to access the system. Each component communicates via a predefined set of TCP/IP socket based messages. This flexible architecture makes integration easier and more robust, and enables separate software components to run on the same or different computers independent of hardware or software platform.
Introducing the Computer to Family Practice
Petreman, Mel
1984-01-01
The medical profession has been far more reluctant than the general business community to adopt the computer as a useful business tool. The experience of a group of five family physicians who have been using a computer since 1979 demonstrates that it is possible to achieve significant financial benefits, and to reduce the stress and workload of both physicians and office staff. The computerization of medical records, scheduling, and patient billing is discussed in detail. Physicians have controlled the paper load of the modern medical office by pioneering their own medical software system. PMID:21279036
Hannon, Tamara S; Dugan, Tamara M; Saha, Chandan K; McKee, Steven J; Downs, Stephen M; Carroll, Aaron E
2017-04-01
Type 2 diabetes (T2D) is increasingly common in young individuals. Primary prevention and screening among children and adolescents who are at substantial risk for T2D are recommended, but implementation of T2D screening practices in the pediatric primary care setting is uncommon. To determine the feasibility and effectiveness of a computerized clinical decision support system to identify pediatric patients at high risk for T2D and to coordinate screening for and diagnosis of prediabetes and T2D. This cluster-randomized clinical trial included patients from 4 primary care pediatric clinics. Two clinics were randomized to the computerized clinical decision support intervention, aimed at physicians, and 2 were randomized to the control condition. Patients of interest included children, adolescents, and young adults 10 years or older. Data were collected from January 1, 2013, through December 1, 2016. Comparison of physician screening and follow-up practices after adding a T2D module to an existing computer decision support system. Electronic medical record (EMR) data from patients 10 years or older were reviewed to determine the rates at which pediatric patients were identified as having a body mass index (BMI) at or above the 85th percentile and 2 or more risk factors for T2D and underwent screening for T2D. Medical records were reviewed for 1369 eligible children (712 boys [52.0%] and 657 girls [48.0%]; median [interquartile range] age, 12.9 [11.2-15.3]), of whom 684 were randomized to the control group and 685 to the intervention group. Of these, 663 (48.4%) had a BMI at or above the 85th percentile. Five hundred sixty-five patients (41.3%) met T2D screening criteria, with no difference between control and intervention sites. The T2D module led to a significant increase in the percentage of patients undergoing screening for T2D (89 of 283 [31.4%] vs 26 of 282 [9.2%]; adjusted odds ratio, 4.6; 95% CI, 1.5-14.7) and a greater proportion attending a scheduled follow-up appointment (45 of 153 [29.4%] vs 38 of 201 [18.9%]; adjusted odds ratio, 1.8; 95% CI, 1.5-2.2). Use of a computerized clinical decision support system to automate the identification and screening of pediatric patients at high risk for T2D can help overcome barriers to the screening process. The support system significantly increased screening among patients who met the American Diabetes Association criteria and adherence to follow-up appointments with primary care clinicians. clinicaltrials.gov Identifier: NCT01814787.
NASA Astrophysics Data System (ADS)
Valdman, V. V.; Gridnev, S. O.
2017-10-01
The article examines into the vital issues of measuring and calculating the raw stock volumes in covered storehouses at mining and processing plants. The authors bring out two state-of-the-art high-technology solutions: 1 - to use the ground-based laser scanning system (the method is reasonably accurate and dependable, but costly and time consuming; it also requires the stoppage of works in the storehouse); 2 - to use the fundamentally new computerized stocktaking system in mine surveying for the ore mineral volume calculation, based on the profile digital images. These images are obtained via vertical projection of the laser plane onto the surface of the stored raw materials.
Commentary: the postdoctoral residency match in clinical neuropsychology.
Bodin, Doug; Grote, Christopher L
2016-07-01
Postdoctoral recruitment in clinical neuropsychology has evolved significantly over the past two decades. Prior to 1994, there were no organized recruitment guidelines for the specialty. From 1994 to 2001, the Association of Postdoctoral Programs in Clinical Neuropsychology (APPCN) facilitated a uniform notification date where member programs agreed to not make offers prior to a specified date. In 2001, APPCN partnered with National Matching Services to administer a computerized match recruitment system. Presently, not all programs participate in the match. This often results in students applying to 'match' and 'non-match' programs which can lead to significant stress on the part of applicants and program directors. This issue has recently become the focus of journal articles and public discussions. The goals of this paper were to review the history of postdoctoral recruitment in clinical neuropsychology, review the benefits of coordinated recruitment systems, review the structure and function of the computerized match, and explain why the computerized match for postdoctoral recruitment in clinical neuropsychology is beneficial for the specialty of clinical neuropsychology.
Georgieva, Antoniya; Payne, Stephen J; Moulden, Mary; Redman, Christopher W G
2011-01-01
We applied computerized methods to assess the Electronic Fetal Monitoring (EFM) in labor. We analyzed retrospectively the last hour of EFM for 1,370 babies, delivered by emergency Cesarean sections before the onset of pushing (data collected at the John Radcliffe Hospital, Oxford, UK). There were two cohorts according to the reason for intervention: (a) fetal distress, n(1) = 524 and (b) failure to progress and/or malpresentation, n(2) = 846. The cohorts were compared in terms of classical EFM features (baseline, decelerations, variability and accelerations), computed by a dedicated Oxford system for automated analysis--OxSys. In addition, OxSys was employed to simulate current clinical guidelines for the classification of fetal monitoring, i.e. providing in real time a three-tier grading system of the EFM (normal, indeterminate, or abnormal). The computerized features and the simulated guidelines corresponded well to the clinical management and to the actual labor outcome (measured by umbilical arterial pH).
Information integrity and privacy for computerized medical patient records
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos, J.; Hamilton, V.; Gaylor, T.
Sandia National Laboratories and Oceania, Inc. entered into a Cooperative Research and Development Agreement (CRADA) in November 1993 to provide ``Information Integrity and Privacy for Computerized Medical Patient Records`` (CRADA No. SC93/01183). The main objective of the project was to develop information protection methods that are appropriate for databases of patient records in health information systems. This document describes the findings and alternative solutions that resulted from this CRADA.
Healthtrak(tm): Technology Enhanced Human Interface to the Computerized Patient Record
2002-07-01
and/or findings contained in this report are those of the author( s ) and should not be construed as an official Department of the Army position...34: Technology Enhanced Human Interface to the DAMDI17-02-C-0032 Computerized Patient Record 6. AUTHOR( S ) Azad M. Madni, Ph.D. Doctor Weiwen Lin Carla...C. Madni 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Intelligent Systems Technology, Incorporated
Computerized dynamic posturography: the influence of platform stability on postural control.
Palm, Hans-Georg; Lang, Patricia; Strobel, Johannes; Riesner, Hans-Joachim; Friemert, Benedikt
2014-01-01
Postural stability can be quantified using posturography systems, which allow different foot platform stability settings to be selected. It is unclear, however, how platform stability and postural control are mathematically correlated. Twenty subjects performed tests on the Biodex Stability System at all 13 stability levels. Overall stability index, medial-lateral stability index, and anterior-posterior stability index scores were calculated, and data were analyzed using analysis of variance and linear regression analysis. A decrease in platform stability from the static level to the second least stable level was associated with a linear decrease in postural control. The overall stability index scores were 1.5 ± 0.8 degrees (static), 2.2 ± 0.9 degrees (level 8), and 3.6 ± 1.7 degrees (level 2). The slope of the regression lines was 0.17 for the men and 0.10 for the women. A linear correlation was demonstrated between platform stability and postural control. The influence of stability levels seems to be almost twice as high in men as in women.
Hemens, Brian J; Holbrook, Anne; Tonkin, Marita; Mackay, Jean A; Weise-Kelly, Lorraine; Navarro, Tamara; Wilczynski, Nancy L; Haynes, R Brian
2011-08-03
Computerized clinical decision support systems (CCDSSs) for drug therapy management are designed to promote safe and effective medication use. Evidence documenting the effectiveness of CCDSSs for improving drug therapy is necessary for informed adoption decisions. The objective of this review was to systematically review randomized controlled trials assessing the effects of CCDSSs for drug therapy management on process of care and patient outcomes. We also sought to identify system and study characteristics that predicted benefit. We conducted a decision-maker-researcher partnership systematic review. We updated our earlier reviews (1998, 2005) by searching MEDLINE, EMBASE, EBM Reviews, Inspec, and other databases, and consulting reference lists through January 2010. Authors of 82% of included studies confirmed or supplemented extracted data. We included only randomized controlled trials that evaluated the effect on process of care or patient outcomes of a CCDSS for drug therapy management compared to care provided without a CCDSS. A study was considered to have a positive effect (i.e., CCDSS showed improvement) if at least 50% of the relevant study outcomes were statistically significantly positive. Sixty-five studies met our inclusion criteria, including 41 new studies since our previous review. Methodological quality was generally high and unchanged with time. CCDSSs improved process of care performance in 37 of the 59 studies assessing this type of outcome (64%, 57% of all studies). Twenty-nine trials assessed patient outcomes, of which six trials (21%, 9% of all trials) reported improvements. CCDSSs inconsistently improved process of care measures and seldomly improved patient outcomes. Lack of clear patient benefit and lack of data on harms and costs preclude a recommendation to adopt CCDSSs for drug therapy management.
Barlough, J E; Jacobson, R H; Downing, D R; Lynch, T J; Scott, F W
1987-01-01
The computer-assisted, kinetics-based enzyme-linked immunosorbent assay for coronavirus antibodies in cats was calibrated to the conventional indirect immunofluorescence assay by linear regression analysis and computerized interpolation (generation of "immunofluorescence assay-equivalent" titers). Procedures were developed for normalization and standardization of kinetics-based enzyme-linked immunosorbent assay results through incorporation of five different control sera of predetermined ("expected") titer in daily runs. When used with such sera and with computer assistance, the kinetics-based enzyme-linked immunosorbent assay minimized both within-run and between-run variability while allowing also for efficient data reduction and statistical analysis and reporting of results. PMID:3032390
Barlough, J E; Jacobson, R H; Downing, D R; Lynch, T J; Scott, F W
1987-01-01
The computer-assisted, kinetics-based enzyme-linked immunosorbent assay for coronavirus antibodies in cats was calibrated to the conventional indirect immunofluorescence assay by linear regression analysis and computerized interpolation (generation of "immunofluorescence assay-equivalent" titers). Procedures were developed for normalization and standardization of kinetics-based enzyme-linked immunosorbent assay results through incorporation of five different control sera of predetermined ("expected") titer in daily runs. When used with such sera and with computer assistance, the kinetics-based enzyme-linked immunosorbent assay minimized both within-run and between-run variability while allowing also for efficient data reduction and statistical analysis and reporting of results.
The horizontal computerized rotational impulse test.
Furman, Joseph M; Shirey, Ian; Roxberg, Jillyn; Kiderman, Alexander
2016-01-01
Whole-body impulsive rotations were used to overcome several limitations associated with manual head impulse testing. A computer-controlled rotational chair delivered brief, whole-body, earth-vertical axis yaw impulsive rotations while eye movements were measured using video-oculography. Results from an unselected group of 20 patients with dizziness and a group of 22 control subjects indicated that the horizontal computerized rotational head impulse test (crHIT) is well-tolerated and provides an estimate of unidirectional vestibulo-ocular reflex gain comparable to results from caloric testing. This study demonstrates that the horizontal crHIT is a new assessment tool that overcomes many of the limitations of manual head impulse testing and provides a reliable laboratory-based measure of unilateral horizontal semicircular canal function.
A new color vision test to differentiate congenital and acquired color vision defects.
Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak
2007-07-01
To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.
Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela
2018-03-27
The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge after sedation.
Brachytherapy of prostate cancer after colectomy for colorectal cancer: pilot experience.
Koutrouvelis, Panos G; Theodorescu, Dan; Katz, Stuart; Lailas, Niko; Hendricks, Fred
2005-01-01
We present a method of brachytherapy for prostate cancer using a 3-dimensional stereotactic system and computerized tomography guidance in patients without a rectum due to previous treatment for colorectal cancer. From June 1994 to November 2003 a cohort of 800 patients were treated with brachytherapy for prostate cancer. Four patients had previously been treated for colorectal cancer with 4,500 cGy external beam radiation therapy, abdominoperineal resection and chemotherapy, while 1 underwent abdominoperineal resection alone for ulcerative colitis. Because of previous radiation therapy, these patients were not candidates for salvage external beam radiation therapy or radical prostatectomy and they had no rectum for transrectal ultrasound guided transperineal brachytherapy or cryotherapy. A previously described, 3-dimensional stereotactic system was used for brachytherapy in these patients. The prescribed radiation dose was 120 to 144 Gy with iodine seeds in rapid strand format. Patient followup included clinical examination and serum prostate specific antigen measurement. Average followup was 18.6 months. Four patients had excellent biochemical control, while 1 had biochemical failure. Patients did not experience any gastrointestinal morbidity. One patient had a stricture of the distal ureter, requiring a stent. Three-dimensional computerized tomography guided brachytherapy for prostate cancer in patients with a history of colorectal cancer who have no rectum is a feasible method of treatment.
Computerizing medical records in Japan.
Yasunaga, Hideo; Imamura, Tomoaki; Yamaki, Shintaro; Endo, Hiroyoshi
2008-10-01
The present study reports the current status of computerizing medical records in Japan. In 2001, the Ministry of Health, Labour and Welfare formulated the Grand Design for the Development of Information Systems in the Healthcare and Medical Fields. The Grand Design stated a numerical target for "spreading the use of electronic medical records (EMR) in at least 60% of Japan's hospitals with 400 or more beds by 2006." The objective of this study was to examine the extent to which EMR and order entry systems (OES) have been adopted as of February 2007 and to evaluate the Japanese government's policy regarding the computerization of medical records. We conducted a postal survey targeting medical institutions throughout Japan. In February 2007, we mailed self-administered questionnaires to all 1574 hospitals with 300 or more beds, and to a random selection of 1000 hospitals with less than 300 beds in addition to 4000 clinics. Responses were received from 812 (51.6%), 504 (50.5%), and 1769 (44.8%), respectively. We asked questions concerning: (i) the extent to which EMR and OES had been introduced; (ii) the reasons why certain institutions had not introduced EMR and (iii) the subjective evaluation of the efficacy and cost-effectiveness of EMR. The percentage of institutions that had introduced EMR as of February 2007 was 10.0% for hospitals and 10.1% for clinics. Even the percentage for hospitals with 400 or more beds was just 31.2%, illustrating that the government's target had not been reached. The most common reason given for not introducing EMR was: "The cost is high" which was observed in 82.0% of hospitals. It was considered that the introduction of EMR could improve 'inter-hospital networks', and 'time efficiency for physicians' by around 45% and 25% of hospitals, respectively. Healthcare information computerization in Japan is behind schedule because the introductory costs are high. For the computerization of healthcare information to be further promoted, prices of EMR systems should be lowered to a level which individual hospitals can afford. Furthermore, the communication between EMR systems should be further standardized to secure functional and semantic interoperability in Japan.
Development and evaluation of an instantaneous atmospheric corrosion rate monitor
NASA Astrophysics Data System (ADS)
Mansfeld, F.; Jeanjaquet, S. L.; Kendig, M. W.; Roe, D. K.
1985-06-01
A research program was carried out in which a new instantaneous atmospheric corrosion rate monitor (ACRM) was developed and evaluated, and equipment was constructed which will allow the use of many sensors in an economical way in outdoor exposures. In the first task, the ACRM was developed and tested in flow chambers in which relative humidity and gaseous and particulate pollutant levels can be controlled. Diurnal cycles and periods of rain were simulated. The effects of aerosols were studied. A computerized system was used for collection, storage, and analysis of the electrochemical data. In the second task, a relatively inexpensive electronics system for control of the ACRM and measurement of atmospheric corrosion rates was designed and built. In the third task, calibration of deterioration rates of various metallic and nonmetallic materials with the response of the ACRMs attached to these materials was carried out under controlled environmental conditions using the system developed in the second task. A Quality Assurance project plan was prepared with inputs from the Rockwell International Environmental Monitoring and Service Center and Quality Assurance System audits were performed.
Destabilization of Human Balance Control by Static and Dynamic Head Tilts
NASA Technical Reports Server (NTRS)
Paloski, William H.; Wood, Scott J.; Feiveson, Alan H.; Black, F. Owen; Hwang, Emma Y.; Reschke, Millard F.
2004-01-01
To better understand the effects of varying head movement frequencies on human balance control, 12 healthy adult humans were studied during static and dynamic (0.14,0.33,0.6 Hz) head tilts of +/-30deg in the pitch and roll planes. Postural sway was measured during upright stance with eyes closed and altered somatosensory inputs provided by a computerized dynamic posturography (CDP) system. Subjects were able to maintain upright stance with static head tilts, although postural sway was increased during neck extension. Postural stability was decreased during dynamic head tilts, and the degree of destabilization varied directly with increasing frequency of head tilt. In the absence of vision and accurate foot support surface inputs, postural stability may be compromised during dynamic head tilts due to a decreased ability of the vestibular system to discern the orientation of gravity.
Nuttall, Gregory A; Abenstein, John P; Stubbs, James R; Santrach, Paula; Ereth, Mark H; Johnson, Pamela M; Douglas, Emily; Oliver, William C
2013-04-01
To determine whether the use of a computerized bar code-based blood identification system resulted in a reduction in transfusion errors or near-miss transfusion episodes. Our institution instituted a computerized bar code-based blood identification system in October 2006. After institutional review board approval, we performed a retrospective study of transfusion errors from January 1, 2002, through December 31, 2005, and from January 1, 2007, through December 31, 2010. A total of 388,837 U were transfused during the 2002-2005 period. There were 6 misidentification episodes of a blood product being transfused to the wrong patient during that period (incidence of 1 in 64,806 U or 1.5 per 100,000 transfusions; 95% CI, 0.6-3.3 per 100,000 transfusions). There was 1 reported near-miss transfusion episode (incidence of 0.3 per 100,000 transfusions; 95% CI, <0.1-1.4 per 100,000 transfusions). A total of 304,136 U were transfused during the 2007-2010 period. There was 1 misidentification episode of a blood product transfused to the wrong patient during that period when the blood bag and patient's armband were scanned after starting to transfuse the unit (incidence of 1 in 304,136 U or 0.3 per 100,000 transfusions; 95% CI, <0.1-1.8 per 100,000 transfusions; P=.14). There were 34 reported near-miss transfusion errors (incidence of 11.2 per 100,000 transfusions; 95% CI, 7.7-15.6 per 100,000 transfusions; P<.001). Institution of a computerized bar code-based blood identification system was associated with a large increase in discovered near-miss events. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Medical student, resident, and faculty use of a computerized literature searching system.
Markert, R J; Parisi, A J; Barnes, H V; Cohen, S; Goldenberg, K; Mieczkowski, L E; Dunn, M; Siervogel, R M
1989-04-01
The experiences of medical students, residents, and faculty with a computerized literature searching system were evaluated. Third-year medical students, internal medicine and family practice residents, and full-time and voluntary faculty at one medical school had the opportunity to use a full-text and bibliographic medical literature retrieval system free of charge for an eleven-month period. Subjects conducted nearly nine thousand literature searches over a period of 942 system hours. Questionnaire data showed that participants could learn to use and would use an electronic information system, felt capable of using the system, utilized the system for a variety of purposes and in a number of different ways, and viewed the system as a valuable tool in searching the medical literature. The results are discussed in the context of the educational needs of the four user-groups and medical education planning by institutions.
Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hullar, Ted; Anastasio, Cort, E-mail: canastasio@ucdavis.edu; Paige, David F.
2014-04-15
High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °Cmore » ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.« less
Preliminary analysis of long-range aircraft designs for future heavy airlift missions
NASA Technical Reports Server (NTRS)
Nelms, W. P., Jr.; Murphy, R.; Barlow, A.
1976-01-01
A computerized design study of very large cargo aircraft for the future heavy airlift mission was conducted using the Aircraft Synthesis program (ACSYNT). The study was requested by the Air Force under an agreement whereby Ames provides computerized design support to the Air Force Flight Dynamics Laboratory. This effort is part of an overall Air Force program to study advanced technology large aircraft systems. Included in the Air Force large aircraft program are investigations of missions such as heavy airlift, airborne missile launch, battle platform, command and control, and aerial tanker. The Ames studies concentrated on large cargo aircraft of conventional design with payloads from 250,000 to 350,000 lb. Range missions up to 6500 n.mi. and radius missions up to 3600 n.mi. have been considered. Takeoff and landing distances between 7,000 and 10,000 ft are important constraints on the configuration concepts. The results indicate that a configuration employing conventional technology in all disciplinary areas weighs approximately 2 million pounds to accomplish either a 6500-n.mi. range mission or a 3600-n.mi. radius mission with a 350,000-lb payload.
Thermoelectric property measurements with computer controlled systems
NASA Technical Reports Server (NTRS)
Chmielewski, A. B.; Wood, C.
1984-01-01
A joint JPL-NASA program to develop an automated system to measure the thermoelectric properties of newly developed materials is described. Consideration is given to the difficulties created by signal drift in measurements of Hall voltage and the Large Delta T Seebeck coefficient. The benefits of a computerized system were examined with respect to error reduction and time savings for human operators. It is shown that the time required to measure Hall voltage can be reduced by a factor of 10 when a computer is used to fit a curve to the ratio of the measured signal and its standard deviation. The accuracy of measurements of the Large Delta T Seebeck coefficient and thermal diffusivity was also enhanced by the use of computers.
Nike Facility Diagnostics and Data Acquisition System
NASA Astrophysics Data System (ADS)
Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim
2013-10-01
The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.
Evaluating and selecting an information system, Part 1.
Neal, T
1993-01-01
Initial steps in the process of evaluating and selecting a computerized information system for the pharmacy department are described. The first step in the selection process is to establish a steering committee and a project committee. The steering committee oversees the project, providing policy guidance, making major decisions, and allocating budgeted expenditures. The project committee conducts the departmental needs assessment, identifies system requirements, performs day-to-day functions, evaluates vendor proposals, trains personnel, and implements the system chosen. The second step is the assessment of needs in terms of personnel, workload, physical layout, and operating requirements. The needs assessment should be based on the department's mission statement and strategic plan. The third step is the development of a request for information (RFI) and a request for proposal (RFP). The RFI is a document designed for gathering preliminary information from a wide range of vendors; this general information is used in deciding whether to send the RFP to a given vendor. The RFP requests more detailed information and gives the purchaser's exact specifications for a system; the RFP also includes contractual information. To help ensure project success, many institutions turn to computer consultants for guidance. The initial steps in selecting a computerized pharmacy information system are establishing computerization committees, conducting a needs assessment, and writing an RFI and an RFP. A crucial early decision is whether to seek a consultant's expertise.
Moja, Lorenzo; Polo Friz, Hernan; Capobussi, Matteo; Kwag, Koren; Banzi, Rita; Ruggiero, Francesca; González-Lorenzo, Marien; Liberati, Elisa Giulia; Mangia, Massimo; Nyberg, Peter; Kunnamo, Ilkka; Cimminiello, Claudio; Vighi, Giuseppe; Grimshaw, Jeremy; Bonovas, Stefanos
2016-07-07
Computerized decision support systems (CDSSs) are information technology-based software that provide health professionals with actionable, patient-specific recommendations or guidelines for disease diagnosis, treatment, and management at the point-of-care. These messages are intelligently filtered to enhance the health and clinical care of patients. CDSSs may be integrated with patient electronic health records (EHRs) and evidence-based knowledge. We designed a pragmatic randomized controlled trial to evaluate the effectiveness of patient-specific, evidence-based reminders generated at the point-of-care by a multi-specialty decision support system on clinical practice and the quality of care. We will include all the patients admitted to the internal medicine department of one large general hospital. The primary outcome is the rate at which medical problems, which are detected by the decision support software and reported through the reminders, are resolved (i.e., resolution rates). Secondary outcomes are resolution rates for reminders specific to venous thromboembolism (VTE) prevention, in-hospital all causes and VTE-related mortality, and the length of hospital stay during the study period. The adoption of CDSSs is likely to increase across healthcare systems due to growing concerns about the quality of medical care and discrepancy between real and ideal practice, continuous demands for a meaningful use of health information technology, and the increasing use of and familiarity with advanced technology among new generations of physicians. The results of our study will contribute to the current understanding of the effectiveness of CDSSs in primary care and hospital settings, thereby informing future research and healthcare policy questions related to the feasibility and value of CDSS use in healthcare systems. This trial is seconded by a specialty trial randomizing patients in an oncology setting (ONCO-CODES). ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT02577198?term=NCT02577198&rank=1.
Computerized measures of finger tapping: reliability, malingering and traumatic brain injury.
Hubel, Kerry A; Yund, E William; Herron, Timothy J; Woods, David L
2013-01-01
We analyzed computerized finger tapping metrics in four experiments. Experiment 1 showed tapping-rate differences associated with hand dominance, digits, sex, and fatigue that replicated those seen in a previous, large-scale community sample. Experiment 2 revealed test-retest correlations (r = .91) that exceeded those reported in previous tapping studies. Experiment 3 investigated subjects simulating symptoms of traumatic brain injury (TBI); 62% of malingering subjects produced abnormally slow tapping rates. A tapping-rate malingering index, based on rate-independent tapping patterns, provided confirmatory evidence of malingering in 48% of the subjects with abnormal tapping rates. Experiment 4 compared tapping in 24 patients with mild TBI (mTBI) and a matched control group; mTBI patients showed slowed tapping without evidence of malingering. Computerized finger tapping measures are reliable measures of motor speed, useful in detecting subjects performing with suboptimal effort, and are sensitive to motor abnormalities following mTBI.
NASA Technical Reports Server (NTRS)
Hyle, C. T.; Lunde, A. N.
1972-01-01
The development of a computerized capability to depict views from the Apollo spacecraft during a lunar mission was undertaken before the Apollo 8 mission. Such views were considered valuable because of the difficulties in visualizing the complex geometry of the Earth, Moon, Sun, and spacecraft. Such visualization capability originally was desired for spacecraft attitude verification and contingency situations. Improvements were added for later Apollo flights, and results were adopted for several real time and preflight applications. Some specific applications have included crewmember and ground control personnel familiarization, nominal and contingency mission planning, definition of secondary attitude checks for all major thrust maneuvers, and preflight star selection for navigation and for platform alinement. The use of this computerized visualization capability should prove valuable for any future space program as an aid to understanding the geometrical relationships between the spacecraft and the celestial surroundings.
Computerized resources in language therapy with children of the autistic spectrum.
Fernandes, Fernanda Dreux Miranda; Santos, Thaís Helena Ferreira; Amato, Cibelle Albuquerque de la Higuera; Molini-Avejonas, Daniela Regina
2010-01-01
The use of computerized technology in language therapy with children of the autistic spectrum. To assess the interference of using computers and specific programs during language therapy in the functional communicative profile and socio-cognitive performance of children of the autistic spectrum. 23 children with ages ranging between 3 and 12 years were individually video recorded prior to and after a set of 10 regular language therapy sessions (i.e. a total of two video samples per subject) using computerized games according to the child's choice. The following expressions were used by the therapists to describe the children's performance during the use of computers: more attentive, more communicative initiatives, more eye contact, more interactive, more verbalizations, more attention and more action requests. Qualitative and quantitative progresses were identified, although without statistical significance. Those progresses were observed after a time period that is smaller than the usually applied to this kind of comparison and it seems to be a promising result. More controlled associations and comparisons were not possible due to the groups' heterogeneity and therefore more consistent conclusions are not possible. It was clear that the subjects presented different reactions to the use of computerized resources during language therapy.
Stein, Bradley D; Kogan, Jane N; Mihalyo, Mark J; Schuster, James; Deegan, Patricia E; Sorbero, Mark J; Drake, Robert E
2013-04-01
Healthcare reform emphasizes patient-centered care and shared decision-making. This study examined the impact on psychotropic adherence of a decision support center and computerized tool designed to empower and activate consumers prior to an outpatient medication management visit. Administrative data were used to identify 1,122 Medicaid-enrolled adults receiving psychotropic medication from community mental health centers over a two-year period from community mental health centers. Multivariate linear regression models were used to examine if tool users had higher rates of 180-day medication adherence than non-users. Older clients, Caucasian clients, those without recent hospitalizations, and those who were Medicaid-eligible due to disability had higher rates of 180-day medication adherence. After controlling for sociodemographics, clinical characteristics, baseline adherence, and secular changes over time, using the computerized tool did not affect adherence to psychotropic medications. The computerized decision tool did not affect medication adherence among clients in outpatient mental health clinics. Additional research should clarify the impact of decision-making tools on other important outcomes such as engagement, patient-prescriber communication, quality of care, self-management, and long-term clinical and functional outcomes.
The development of the Medical Literature Analysis and Retrieval System (MEDLARS)*
Dee, Cheryl Rae
2007-01-01
Objective: The research provides a chronology of the US National Library of Medicine's (NLM's) contribution to access to the world's biomedical literature through its computerization of biomedical indexes, particularly the Medical Literature Analysis and Retrieval System (MEDLARS). Method: Using material gathered from NLM's archives and from personal interviews with people associated with developing MEDLARS and its associated systems, the author discusses key events in the history of MEDLARS. Discussion: From the development of the early mechanized bibliographic retrieval systems of the 1940s and to the beginnings of online, interactive computerized bibliographic search systems of the early 1970s chronicled here, NLM's contributions to automation and bibliographic retrieval have been extensive. Conclusion: As NLM's technological experience and expertise grew, innovative bibliographic storage and retrieval systems emerged. NLM's accomplishments regarding MEDLARS were cutting edge, placing the library at the forefront of incorporating mechanization and technologies into medical information systems. PMID:17971889
Girls on the move program to increase physical activity participation.
Robbins, Lorraine B; Gretebeck, Kimberlee A; Kazanis, Anamaria S; Pender, Nola J
2006-01-01
Because physical inactivity poses serious health risks, interventions are urgently needed to reverse the increasingly sedentary lifestyles of adolescent girls. The aim of this study was to determine the feasibility of "Girls on the Move," an individually tailored computerized physical activity (PA) program plus nurse counseling intervention, in increasing PA. A pretest-posttest control group design was used with 77 racially diverse sedentary girls in Grades 6, 7, and 8 from two middle schools. Each of the instructional grades was randomly assigned to either an intervention or control condition. After completing computerized questionnaires, each girl in the control group received a handout listing the PA recommendations. To encourage PA, each girl in the intervention group received computerized, individually tailored feedback messages based on her responses to the questionnaires, individual counseling from the school's pediatric nurse practitioner (PNP), and telephone calls and mailings from a trained research assistant. At 12 weeks, girls in both groups responded to the questionnaires. No differences in self-reported PA emerged between the intervention and control groups at Weeks 1 (baseline) and 12 (postintervention). Repeated measures ANOVA showed a significant interaction between group and time for social support for PA, F(1, 69) = 5.73, p = .019, indicating that the intervention group had significantly greater social support across time than did the control group. From baseline to postintervention, social support increased for the intervention group but decreased for the control group. Reasons for the lack of significant differences between the groups on the PA measures were cited. Important information that could inform subsequent studies that test interventions to increase youth PA was acquired from conducting this study. Future efforts to increase PA participation might include this approach for enhancing social support for PA.
Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
Kolokitha, Olga-Elpis
2007-01-01
Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468