Sample records for computerized graphical tools

  1. Computerized symptom and quality-of-life assessment for patients with cancer part II: acceptability and usability.

    PubMed

    Mullen, Kristin H; Berry, Donna L; Zierler, Brenda K

    2004-09-01

    To determine the acceptability and usability of a computerized quality-of-life (QOL) and symptom assessment tool and the graphically displayed QOL and symptom output in an ambulatory radiation oncology clinic. Descriptive, cross-sectional. Radiation oncology clinic located in an urban university medical center. 45 patients with cancer being evaluated for radiation therapy and 10 clinicians, who submitted 12 surveys. Acceptability of the computerized assessment was measured with an online, 16-item, Likert-style survey delivered as 45 patients undergoing radiation therapy completed a 25-item QOL and symptom assessment. Usability of the graphic output was assessed with clinician completion of a four-item paper survey. Acceptability and usability of computerized patient assessment. The patient acceptability survey indicated that 70% (n = 28) liked computers and 10% (n = 4) did not. The program was easy to use for 79% (n = 26), easy to understand for 91% (n = 30), and enjoyable for 71% (n = 24). Seventy-six percent (n = 25) believed that the amount of time needed to complete the computerized survey was acceptable. Sixty-six percent (n = 21) responded that they were satisfied with the program, and none of the participants chose the very dissatisfied response. Eighty-three percent (n = 10) of the clinicians found the graphic output helpful in promoting communication with patients, 75% (n = 9) found the output report helpful in identifying appropriate areas of QOL deficits or concerns, and 83% (n = 10) indicated that the output helped guide clinical interactions with patients. The computer-based QOL and symptom assessment tool is acceptable to patients, and the graphically displayed QOL and symptom output is useful to radiation oncology nurses and physicians. Wider application of computerized patient-generated data can continue in various cancer settings and be tested for clinical and organizational outcomes.

  2. Computerized Biomechanical Man-Model

    DTIC Science & Technology

    1976-07-01

    Force Systems Command Wright-Patterson AFB, Ohio ABSTRACT The COMputerized BIomechanical MAN-Model (called COMBIMAN) is a computer interactive graphics...concept was to build a mock- The use of mock-ups for biomechanical evalua- up which permitted the designer to visualize the tion has long been a tool...of the can become an obstacle to design change. Aerospace Medical Research Laboratory, we are developing a computerized biomechanical man-model

  3. Visualizing Practice with Children and Families.

    ERIC Educational Resources Information Center

    Mattaini, Mark A.

    1995-01-01

    Argues that graphic images and technologies can be of substantial help to social work practitioners for assessment and intervention with children and families. Suggests a range of graphic tools and techniques, including profiles, ecomaps, sequential ecomaps, contingency diagrams, concurrent graphing, and computerized Visual EcoScan. (DR)

  4. Development of a Traditional/Computer-aided Graphics Course for Engineering Technology.

    ERIC Educational Resources Information Center

    Anand, Vera B.

    1985-01-01

    Describes a two-semester-hour freshman course in engineering graphics which uses both traditional and computerized instruction. Includes course description, computer graphics topics, and recommendations. Indicates that combining interactive graphics software with development of simple programs gave students a better foundation for upper-division…

  5. CTG Analyzer: A graphical user interface for cardiotocography.

    PubMed

    Sbrollini, Agnese; Agostinelli, Angela; Burattini, Luca; Morettini, Micaela; Di Nardo, Francesco; Fioretti, Sandro; Burattini, Laura

    2017-07-01

    Cardiotocography (CTG) is the most commonly used test for establishing the good health of the fetus during pregnancy and labor. CTG consists in the recording of fetal heart rate (FHR; bpm) and maternal uterine contractions (UC; mmHg). FHR is characterized by baseline, baseline variability, tachycardia, bradycardia, acceleration and decelerations. Instead, UC signal is characterized by presence of contractions and contractions period. Such parameters are usually evaluated by visual inspection. However, visual analysis of CTG recordings has a well-demonstrated poor reproducibility, due to the complexity of physiological phenomena affecting fetal heart rhythm and being related to clinician's experience. Computerized tools in support of clinicians represents a possible solution for improving correctness in CTG interpretation. This paper proposes CTG Analyzer as a graphical tool for automatic and objective analysis of CTG tracings. CTG Analyzer was developed under MATLAB®; it is a very intuitive and user friendly graphical user interface. FHR time series and UC signal are represented one under the other, on a grid with reference lines, as usually done for CTG reports printed on paper. Colors help identification of FHR and UC features. Automatic analysis is based on some unchangeable features definitions provided by the FIGO guidelines, and other arbitrary settings whose default values can be changed by the user. Eventually, CTG Analyzer provides a report file listing all the quantitative results of the analysis. Thus, CTG Analyzer represents a potentially useful graphical tool for automatic and objective analysis of CTG tracings.

  6. Speaking Out for Yourself: A Self-Help Guide

    MedlinePlus

    ... his field as a graphic designer. Through his research he found that there were openings for graphic designers in his community. However, he also learned that in the years that he had been unable to work, all graphic design work had become computerized. His computer design skills ...

  7. A graphics-oriented personal computer-based microscope charting system for neuroanatomical and neurochemical studies.

    PubMed

    Tourtellotte, W G; Lawrence, D T; Getting, P A; Van Hoesen, G W

    1989-07-01

    This report describes a computerized microscope charting system based on the IBM personal computer or compatible. Stepping motors are used to control the movement of the microscope stage and to encode its position by hand manipulation of a joystick. Tissue section contours and the location of cells labeled with various compounds are stored by the computer, plotted at any magnification and manipulated into composites created from several charted sections. The system has many advantages: (1) it is based on an industry standardized computer that is affordable and familiar; (2) compact and commercially available stepping motor microprocessors control the stage movement. These controllers increase reliability, simplify implementation, and increase efficiency by relieving the computer of time consuming control tasks; (3) the system has an interactive graphics interface allowing the operator to view the image during data collection. Regions of the graphics display can be enlarged during the charting process to provide higher resolution and increased accuracy; (4) finally, the digitized data are stored at 0.5 micron resolution and can be routed directly to a multi-pen plotter or exported to a computer-aided design (CAD) program to generate a publication-quality montage composed of several computerized chartings. The system provides a useful tool for the acquisition and qualitative analysis of data representing stained cells or chemical markers in tissue. The modular design, together with data storage at high resolution, allows for potential analytical enhancements involving planimetric, stereologic and 3-D serial section reconstruction.

  8. Computerized Budget Monitoring.

    ERIC Educational Resources Information Center

    Stein, Julian U.; Rowe, Joe N.

    1989-01-01

    This article discusses the importance of budget monitoring in fiscal management; describes ways in which computerized budget monitoring increases accuracy, efficiency, and flexibility; outlines steps in the budget process; and presents sample reports, generated using the Lotus 1-2-3 spreadsheet and graphics program. (IAH)

  9. Fiscal output data produce versatile graphic-numeric charts

    NASA Technical Reports Server (NTRS)

    Powell, R. W.; Romo, J. J.

    1971-01-01

    Refined computerized plotting system produces low-cost graphic-numeric charts that illustrate fiscal data on monthly incremental or cumulative basis, or both. Output is in the form of hard copy or microfilm, or visual-aid transparencies prepared from hard copy for rapid management status presentations.

  10. Contemporary computerized methods for logging planning

    Treesearch

    Chris B. LeDoux

    1988-01-01

    Contemporary harvest planning graphic software is highlighted with practical applications. Planning results from a production study of the Clearwater Cable Yarder are summarized. Application of the planning methods to evaluation of proposed silvicultural treatments is included. Results show that 3-dimensional graphic analysis of proposed harvesting or silvicultural...

  11. Recorded Music and Graphic Design.

    ERIC Educational Resources Information Center

    Osterer, Irv

    1998-01-01

    Reviews the history of art as an element of music-recording packaging. Describes a project in which students design a jacket for either cassette or CD using a combination of computerized and traditional rendering techniques. Reports that students have been inspired to look into careers in graphic design. (DSK)

  12. MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research

    PubMed Central

    Paul Segars, W.; Tsui, Benjamin M. W.

    2012-01-01

    Recent work in the development of computerized phantoms has focused on the creation of ideal “hybrid” models that seek to combine the realism of a patient-based voxelized phantom with the flexibility of a mathematical or stylized phantom. We have been leading the development of such computerized phantoms for use in medical imaging research. This paper will summarize our developments dating from the original four-dimensional (4-D) Mathematical Cardiac-Torso (MCAT) phantom, a stylized model based on geometric primitives, to the current 4-D extended Cardiac-Torso (XCAT) and Mouse Whole-Body (MOBY) phantoms, hybrid models of the human and laboratory mouse based on state-of-the-art computer graphics techniques. This paper illustrates the evolution of computerized phantoms toward more accurate models of anatomy and physiology. This evolution was catalyzed through the introduction of nonuniform rational b-spline (NURBS) and subdivision (SD) surfaces, tools widely used in computer graphics, as modeling primitives to define a more ideal hybrid phantom. With NURBS and SD surfaces as a basis, we progressed from a simple geometrically based model of the male torso (MCAT) containing only a handful of structures to detailed, whole-body models of the male and female (XCAT) anatomies (at different ages from newborn to adult), each containing more than 9000 structures. The techniques we applied for modeling the human body were similarly used in the creation of the 4-D MOBY phantom, a whole-body model for the mouse designed for small animal imaging research. From our work, we have found the NURBS and SD surface modeling techniques to be an efficient and flexible way to describe the anatomy and physiology for realistic phantoms. Based on imaging data, the surfaces can accurately model the complex organs and structures in the body, providing a level of realism comparable to that of a voxelized phantom. In addition, they are very flexible. Like stylized models, they can easily be manipulated to model anatomical variations and patient motion. With the vast improvement in realism, the phantoms developed in our lab can be combined with accurate models of the imaging process (SPECT, PET, CT, magnetic resonance imaging, and ultrasound) to generate simulated imaging data close to that from actual human or animal subjects. As such, they can provide vital tools to generate predictive imaging data from many different subjects under various scanning parameters from which to quantitatively evaluate and improve imaging devices and techniques. From the MCAT to XCAT, we will demonstrate how NURBS and SD surface modeling have resulted in a major evolutionary advance in the development of computerized phantoms for imaging research. PMID:26472880

  13. MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

    PubMed

    Paul Segars, W; Tsui, Benjamin M W

    2009-12-01

    Recent work in the development of computerized phantoms has focused on the creation of ideal "hybrid" models that seek to combine the realism of a patient-based voxelized phantom with the flexibility of a mathematical or stylized phantom. We have been leading the development of such computerized phantoms for use in medical imaging research. This paper will summarize our developments dating from the original four-dimensional (4-D) Mathematical Cardiac-Torso (MCAT) phantom, a stylized model based on geometric primitives, to the current 4-D extended Cardiac-Torso (XCAT) and Mouse Whole-Body (MOBY) phantoms, hybrid models of the human and laboratory mouse based on state-of-the-art computer graphics techniques. This paper illustrates the evolution of computerized phantoms toward more accurate models of anatomy and physiology. This evolution was catalyzed through the introduction of nonuniform rational b-spline (NURBS) and subdivision (SD) surfaces, tools widely used in computer graphics, as modeling primitives to define a more ideal hybrid phantom. With NURBS and SD surfaces as a basis, we progressed from a simple geometrically based model of the male torso (MCAT) containing only a handful of structures to detailed, whole-body models of the male and female (XCAT) anatomies (at different ages from newborn to adult), each containing more than 9000 structures. The techniques we applied for modeling the human body were similarly used in the creation of the 4-D MOBY phantom, a whole-body model for the mouse designed for small animal imaging research. From our work, we have found the NURBS and SD surface modeling techniques to be an efficient and flexible way to describe the anatomy and physiology for realistic phantoms. Based on imaging data, the surfaces can accurately model the complex organs and structures in the body, providing a level of realism comparable to that of a voxelized phantom. In addition, they are very flexible. Like stylized models, they can easily be manipulated to model anatomical variations and patient motion. With the vast improvement in realism, the phantoms developed in our lab can be combined with accurate models of the imaging process (SPECT, PET, CT, magnetic resonance imaging, and ultrasound) to generate simulated imaging data close to that from actual human or animal subjects. As such, they can provide vital tools to generate predictive imaging data from many different subjects under various scanning parameters from which to quantitatively evaluate and improve imaging devices and techniques. From the MCAT to XCAT, we will demonstrate how NURBS and SD surface modeling have resulted in a major evolutionary advance in the development of computerized phantoms for imaging research.

  14. The Effects of Computerized Symbol Processor Instruction on the Communication Skills of Nonspeaking Students.

    ERIC Educational Resources Information Center

    Osguthorpe, Russell T.; Li Chang, Linda

    1988-01-01

    A computerized symbol processor system using an Apple IIe computer and a Power Pad graphics tablet was tested with 22 nonspeaking, multiply disabled students. The students were taught to express themselves independently in writing, and they did significantly better than control students on measures of language comprehension and symbol recognition.…

  15. Computerized database management system for breast cancer patients.

    PubMed

    Sim, Kok Swee; Chong, Sze Siang; Tso, Chih Ping; Nia, Mohsen Esmaeili; Chong, Aun Kee; Abbas, Siti Fathimah

    2014-01-01

    Data analysis based on breast cancer risk factors such as age, race, breastfeeding, hormone replacement therapy, family history, and obesity was conducted on breast cancer patients using a new enhanced computerized database management system. My Structural Query Language (MySQL) is selected as the application for database management system to store the patient data collected from hospitals in Malaysia. An automatic calculation tool is embedded in this system to assist the data analysis. The results are plotted automatically and a user-friendly graphical user interface is developed that can control the MySQL database. Case studies show breast cancer incidence rate is highest among Malay women, followed by Chinese and Indian. The peak age for breast cancer incidence is from 50 to 59 years old. Results suggest that the chance of developing breast cancer is increased in older women, and reduced with breastfeeding practice. The weight status might affect the breast cancer risk differently. Additional studies are needed to confirm these findings.

  16. Interactive computer graphics system for structural sizing and analysis of aircraft structures

    NASA Technical Reports Server (NTRS)

    Bendavid, D.; Pipano, A.; Raibstein, A.; Somekh, E.

    1975-01-01

    A computerized system for preliminary sizing and analysis of aircraft wing and fuselage structures was described. The system is based upon repeated application of analytical program modules, which are interactively interfaced and sequence-controlled during the iterative design process with the aid of design-oriented graphics software modules. The entire process is initiated and controlled via low-cost interactive graphics terminals driven by a remote computer in a time-sharing mode.

  17. Testing the Improvement of English as a Foreign Language Instruction among Chinese College Students through Computerized Graphic Visuals

    ERIC Educational Resources Information Center

    Yang, Quan; Miller, Michael; Bai, Kang

    2011-01-01

    The purpose of this study was to determine if animated illustrations would increase the recall and comprehension of a subject matter, English as a foreign language (EFL), among Chinese college students. The study was specifically designed to identify the influence of graphics on Chinese EFL students' learning by comparing abstract versus concrete…

  18. Development of a clinical applicable graphical user interface to automatically detect exercise oscillatory ventilation: The VOdEX-tool.

    PubMed

    Cornelis, Justien; Denis, Tim; Beckers, Paul; Vrints, Christiaan; Vissers, Dirk; Goossens, Maggy

    2017-08-01

    Cardiopulmonary exercise testing (CPET) gained importance in the prognostic assessment of especially patients with heart failure (HF). A meaningful prognostic parameter for early mortality in HF is exercise oscillatory ventilation (EOV). This abnormal respiratory pattern is recognized by hypo- and hyperventilation during CPET. Up until now, assessment of EOV is mainly done upon visual agreement or manual calculation. The purpose of this research was to automate the interpretation of EOV so this prognostic parameter could be readily investigated during CPET. Preliminary, four definitions describing the original characteristics of EOV, were selected and integrated in the "Ventilatory Oscillations during Exercise-tool" (VOdEX-tool), a graphical user interface that allows automate calculation of EOV. A Discrete Meyer Level 2 wavelet transformation appeared to be the optimal filter to apply on the collected breath-by-breath minute ventilation CPET data. Divers aspects of the definitions i.e. cycle length, amplitude, regularity and total duration of EOV were combined and calculated. The oscillations meeting the criteria were visualised. Filter methods and cut-off criteria were made adjustable for clinical application and research. The VOdEX-tool was connected to a database. The VOdEX-tool provides the possibility to calculate EOV automatically and to present the clinician an overview of the presence of EOV at a glance. The computerized analysis of EOV can be made readily available in clinical practice by integrating the tool in the manufactures existing CPET software. The VOdEX-tool enhances assessment of EOV and therefore contributes to the estimation of prognosis in especially patients with HF. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Application of computer graphics in the design of custom orthopedic implants.

    PubMed

    Bechtold, J E

    1986-10-01

    Implementation of newly developed computer modelling techniques and computer graphics displays and software have greatly aided the orthopedic design engineer and physician in creating a custom implant with good anatomic conformity in a short turnaround time. Further advances in computerized design and manufacturing will continue to simplify the development of custom prostheses and enlarge their niche in the joint replacement market.

  20. Computerized Fortune Cookies--a Classroom Treat.

    ERIC Educational Resources Information Center

    Reissman, Rose

    1996-01-01

    Discusses the use of fortune cookie fortunes in a middle school class combined with computer graphics, desktop publishing, and word processing technology to create writing assignments, games, and discussions. Topics include cultural contexts, and students creating their own fortunes. (LRW)

  1. A decision support system for quality of life in head and neck oncology patients.

    PubMed

    Gonçalves, Joaquim J; Rocha, Alvaro M

    2012-02-16

    The assessment of Quality of Life (QoL) is a Medical goal; it is used in clinical research, medical practice, health-related economic studies and in planning health management measures and strategies. The objective of this project is to develop an informational platform to achieve a patient self-assessment with standardized QoL measuring instruments, through friendly software, easy for the user to adapt, which should aid the study of QoL, by promoting the creation of databases and accelerating its statistical treatment and yet generating subsequent useful results in graphical format for the physician analyzes in an appointment immediately after the answers collection. First, a software platform was designed and developed in an action-research process with patients, physicians and nurses. The computerized patient self-assessment with standardized QoL measuring instruments was compared with traditional one, to verify if its use did not influence the patient's answers. For that, the Wilcoxon and t-Student tests were applied. After, we adopted and adapted the mathematic Rash model to make possible the use of QoL measure in the routine appointments. The results show that the computerized patient self-assessment does not influence the patient's answers and can be used as a suitable tool in the routine appointment, because indicates problems which are more difficult to identify in a traditional appointment, improving thus the physician's decisions. The possibility of representing graphically useful results that physician needs to analyze in the appointment, immediately after the answer collection, in an useful time, makes this QoL assessment platform a diagnosis instrument ready to be used routinely in clinical practice.

  2. Texas Christian University (TCU) Short Forms for Assessing Client Needs and Functioning in Addiction Treatment

    PubMed Central

    SIMPSON, D. DWAYNE; JOE, GEORGE W.; KNIGHT, KEVIN; ROWAN-SZAL, GRACE A.; GRAY, JULIE S.

    2012-01-01

    The TCU Short Forms contain a revised and expanded set of assessments for planning and managing addiction treatment services. They are formatted as brief (1-page) forms to measure client needs and functioning, including drug use severity and history (TCUDS II), criminal thinking and cognitive orientation (CTSForm), motivation and readiness for treatment (MOTForm), psychological functioning (PSYForm), social relations and functioning (SOCForm), and therapeutic participation and engagement (ENGForm). These instruments facilitate optically-scanned data entry, computerized scoring, and rapid graphical feedback for clinical decisions. The present study (based on 5,022 inmates from eight residential prison treatment programs) examines evidence on scale reliabilities and measurement structures of these tools. Results confirmed their integrity and usefulness as indicators of individual and group-level therapeutic dynamics. PMID:22505795

  3. Image selection system. [computerized data storage and retrieval system

    NASA Technical Reports Server (NTRS)

    Knutson, M. A.; Hurd, D.; Hubble, L.; Kroeck, R. M.

    1974-01-01

    An image selection (ISS) was developed for the NASA-Ames Research Center Earth Resources Aircraft Project. The ISS is an interactive, graphics oriented, computer retrieval system for aerial imagery. An analysis of user coverage requests and retrieval strategies is presented, followed by a complete system description. Data base structure, retrieval processors, command language, interactive display options, file structures, and the system's capability to manage sets of selected imagery are described. A detailed example of an area coverage request is graphically presented.

  4. An Interior Signage System for the USAF Academy Hospital

    DTIC Science & Technology

    1979-08-01

    manner. Graphic Design - Graphic design is a design for visual communication . Graphic Design Tools - There are four basic graphic design tools available...specializes in the design of two dimensional visual communication components. The graphic designer utilizes the four graphic design tools in developing

  5. Application of a computerized vibroacoustic data bank for random vibration criteria development

    NASA Technical Reports Server (NTRS)

    Ferebee, R. C.

    1982-01-01

    A computerized data bank system was developed for utilization of large amounts of vibration and acoustic data to formulate component random vibration design and test criteria. This system consists of a computer, graphics tablets, and a dry silver hard copier which are all desk top type hardware and occupy minimal space. Currently, the data bank contains data from the Saturn 5 and Titan 3 flight and static test programs. The vibration and acoustic data are stored in the form of power spectral density and one third octave band plots over the frequency range from 20 to 2000 Hz. The data were stored by digitizing each spectral plot by tracing with the graphics tablet. The digitized data were statistically analyzed, and the resulting 97.5 percent confidence levels were stored on tape along with the appropriate structural parameters. Standard extrapolation procedures were programmed for prediction of component random vibration test criteria for new launch vehicle and payload configurations. A user's manual is included to guide potential users through the programs.

  6. Videofile for Law Enforcement

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Components of a videotape storage and retrieval system originally developed for NASA have been adapted as a tool for law enforcement agencies. Ampex Corp., Redwood City, Cal., built a unique system for NASA-Marshall. The first application of professional broadcast technology to computerized record-keeping, it incorporates new equipment for transporting tapes within the system. After completing the NASA system, Ampex continued development, primarily to improve image resolution. The resulting advanced system, known as the Ampex Videofile, offers advantages over microfilm for filing, storing, retrieving, and distributing large volumes of information. The system's computer stores information in digital code rather than in pictorial form. While microfilm allows visual storage of whole documents, it requires a step before usage--developing the film. With Videofile, the actual document is recorded, complete with photos and graphic material, and a picture of the document is available instantly.

  7. Development of medical data information systems

    NASA Technical Reports Server (NTRS)

    Anderson, J.

    1971-01-01

    Computerized storage and retrieval of medical information is discussed. Tasks which were performed in support of the project are: (1) flight crew health stabilization computer system, (2) medical data input system, (3) graphic software development, (4) lunar receiving laboratory support, and (5) Statos V printer/plotter software development.

  8. Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.

    PubMed

    Staszewska, Anna; Zaki, Pearl; Lee, Joon

    2017-10-06

    Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious illness. ©Anna Staszewska, Pearl Zaki, Joon Lee. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 06.10.2017.

  9. Cockpit design and evaluation using interactive graphics

    NASA Technical Reports Server (NTRS)

    Evans, S. M.

    1975-01-01

    A general overview of the characteristics of an interactive graphics system which was developed to assist cockpit engineers design and evaluate work stations was presented. The manikin used in this COMputerized BIomechanical MAN-model (COMBIMAN) was described, as are provisions for generating work stations and assessing interactions between man and environment. The applications of the present system are explained, and critiques of COMBIMAN are presented. The limitations of the existing programs and the requirements of the designers necessitate future revisions and additions to the biomechanical and erogonomic properties of COMBIMAN. Some of these enhancements are discussed.

  10. A computerized system for portrayal of landscape alterations

    Treesearch

    A. E. Stevenson; J. A. Conley; J. B. Carey

    1979-01-01

    The growing public awareness of and participation in the visual resource decision process has stimulated interest to find improved means of accurately and realistically displaying proposed alterations. The traditional artist renderings often lack the accuracy and objectivity needed for critical decisions. One approach, using computer graphics, led to the MOSAIC system...

  11. Demographic Mapping via Computer Graphics.

    ERIC Educational Resources Information Center

    Banghart, Frank W.; And Others

    A computerized system, developed at Florida State University, is designed to locate students and resources on a geographic network. Using addresses of resources and students as input, the system quickly and accurately locates the addresses on a grid and creates a map showing their distribution. This geographical distribution serves as an…

  12. Pedagogical Strategies for Human and Computer Tutoring.

    ERIC Educational Resources Information Center

    Reiser, Brian J.

    The pedagogical strategies of human tutors in problem solving domains are described and the possibility of incorporating these techniques into computerized tutors is examined. GIL (Graphical Instruction in LISP), an intelligent tutoring system for LISP programming, is compared to human tutors teaching the same material in order to identify how the…

  13. Data Bases and Libraries.

    ERIC Educational Resources Information Center

    Cote, L. G.

    A system in which the function of the library is to acquire, store, and organize materials is proposed which separates the reference function into a group of subject specialists backed up by computerized information retrieval systems. This division of labor is caused by the scientific community's need for access to graphic and other specific (not…

  14. The Newsroom to the Year 2001.

    ERIC Educational Resources Information Center

    Keirstead, Phillip O.

    Projections for a possible scenario for a television broadcast newsroom in 2001 would include a nearly completely computerized system, one which will write scripts, select and create graphics, organize newscasts and visuals, keep records, do research, and manage the newsroom from terminals. This computer system will generate many more newscasts…

  15. Use of a computerized medication shared decision making tool in community mental health settings: impact on psychotropic medication adherence.

    PubMed

    Stein, Bradley D; Kogan, Jane N; Mihalyo, Mark J; Schuster, James; Deegan, Patricia E; Sorbero, Mark J; Drake, Robert E

    2013-04-01

    Healthcare reform emphasizes patient-centered care and shared decision-making. This study examined the impact on psychotropic adherence of a decision support center and computerized tool designed to empower and activate consumers prior to an outpatient medication management visit. Administrative data were used to identify 1,122 Medicaid-enrolled adults receiving psychotropic medication from community mental health centers over a two-year period from community mental health centers. Multivariate linear regression models were used to examine if tool users had higher rates of 180-day medication adherence than non-users. Older clients, Caucasian clients, those without recent hospitalizations, and those who were Medicaid-eligible due to disability had higher rates of 180-day medication adherence. After controlling for sociodemographics, clinical characteristics, baseline adherence, and secular changes over time, using the computerized tool did not affect adherence to psychotropic medications. The computerized decision tool did not affect medication adherence among clients in outpatient mental health clinics. Additional research should clarify the impact of decision-making tools on other important outcomes such as engagement, patient-prescriber communication, quality of care, self-management, and long-term clinical and functional outcomes.

  16. Computerized Cognitive Training in Children With Autism and Intellectual Disabilities: Feasibility and Satisfaction Study

    PubMed Central

    Benyakorn, Songpoom; Calub, Catrina A; Riley, Steven J; Schneider, Andrea; Iosif, Ana-Maria; Solomon, Marjorie; Hessl, David

    2018-01-01

    Background Researchers are increasingly interested in testing and developing computerized cognitive training interventions for individuals with autism spectrum disorder due to the limited accessibility of treatments for this disorder. Understanding the feasibility of testing cognitive interventions for this population is critical, especially for individuals with ASD who have low to moderate intellectual ability. Objective The aim of the study was to evaluate the feasibility of computerized cognitive training as measured by attrition rate and a parent satisfaction survey. Methods A total of 26 participants aged 8-17 years with an autism spectrum disorder diagnosis and significant intellectual impairment were enrolled (mean age 11.1 years). They were instructed to complete 25 sessions of Cogmed Working Memory Training in 5 to 6 weeks with coach assistance. Attrition rate and parent satisfaction surveys were measured after the completion of training. Results Most participants (96%, 25/26) completed the training and indicated high satisfaction (>88%). However, among the participants who completed the training, 5 participants (19%) were unable to finish in 6 weeks, the recommended training period by Cogmed. Parents noted various positive (eg, voice-overs) and negative (eg, particular graphic and sounds associated with a stimulus) features of the game that they thought affected their child’s response. Conclusions Children with autism spectrum disorder and intellectual impairments can successfully participate in computerized cognitive training interventions but may require additional weeks to complete the training beyond the time needed for children without intellectual impairments. The overall completion rate, with extended time to complete the training, was high. Developers of cognitive training programs for this population should take into account potential issues regarding the noise level of stimuli and characteristics of the visual graphics. PMID:29802090

  17. Graphic arts techniques and equipment: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Technology utilization of NASA sponsored projects involving graphic arts techniques and equipment is discussed. The subjects considered are: (1) modification to graphics tools, (1) new graphics tools, (3) visual aids for graphics, and (4) graphic arts shop hints. Photographs and diagrams are included to support the written material.

  18. Advanced Composition and the Computerized Library.

    ERIC Educational Resources Information Center

    Hult, Christine

    1989-01-01

    Discusses four kinds of computerized access tools: online catalogs; computerized reference; online database searching; and compact disks and read only memory (CD-ROM). Examines how these technologies are changing research. Suggests how research instruction in advanced writing courses can be refocused to include the new technologies. (RS)

  19. 3-D Imaging In Virtual Environment: A Scientific Clinical and Teaching Tool

    NASA Technical Reports Server (NTRS)

    Ross, Muriel D.; DeVincenzi, Donald L. (Technical Monitor)

    1996-01-01

    The advent of powerful graphics workstations and computers has led to the advancement of scientific knowledge through three-dimensional (3-D) reconstruction and imaging of biological cells and tissues. The Biocomputation Center at NASA Ames Research Center pioneered the effort to produce an entirely computerized method for reconstruction of objects from serial sections studied in a transmission electron microscope (TEM). The software developed, ROSS (Reconstruction of Serial Sections), is now being distributed to users across the United States through Space Act Agreements. The software is in widely disparate fields such as geology, botany, biology and medicine. In the Biocomputation Center, ROSS serves as the basis for development of virtual environment technologies for scientific and medical use. This report will describe the Virtual Surgery Workstation Project that is ongoing with clinicians at Stanford University Medical Center, and the role of the Visible Human data in the project.

  20. Weaving a Syllaweb: Consideration before Constructing an On-line Syllabus.

    ERIC Educational Resources Information Center

    Johnston, Joyce P.

    This paper explores the practical and philosophical issues involved in Web site construction so that the finished site truly reflects its creator. The author uses the term "syllaweb" for a hyperlinked syllabus and declares that it was an outgrowth of Vannevar Bush's original description of computerized graphical communication as a web,…

  1. Desktop Publishing: The Effects of Computerized Formats on Reading Speed and Comprehension.

    ERIC Educational Resources Information Center

    Knupfer, Nancy Nelson; McIsaac, Marina Stock

    1989-01-01

    Describes study that was conducted to determine the effects of two electronic text variables used in desktop publishing on undergraduate students' reading speed and comprehension. Research on text variables, graphic design, instructional text design, and computer screen design is discussed, and further studies are suggested. (22 references) (LRW)

  2. Comprehension and Recall of Television's Computerized Image: An Exploratory Study.

    ERIC Educational Resources Information Center

    Metallinos, Nikos; Chartrand, Sylvie

    This exploratory study of the effects of the new visual communications media imagery (e.g., video games, digital television, and computer graphics) on the visual perception process is designed to provide a theoretical framework for research, introduce appropriate research instruments for such study, and experiment with the application of biometric…

  3. SimulCAT: Windows Software for Simulating Computerized Adaptive Test Administration

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2012-01-01

    Most, if not all, computerized adaptive testing (CAT) programs use simulation techniques to develop and evaluate CAT program administration and operations, but such simulation tools are rarely available to the public. Up to now, several software tools have been available to conduct CAT simulations for research purposes; however, these existing…

  4. The Design and Development of a Computerized Tool Support for Conducting Senior Projects in Software Engineering Education

    ERIC Educational Resources Information Center

    Chen, Chung-Yang; Teng, Kao-Chiuan

    2011-01-01

    This paper presents a computerized tool support, the Meetings-Flow Project Collaboration System (MFS), for designing, directing and sustaining the collaborative teamwork required in senior projects in software engineering (SE) education. Among many schools' SE curricula, senior projects serve as a capstone course that provides comprehensive…

  5. Evaluating a Computerized Aid for Conducting a Cognitive Task Analysis

    DTIC Science & Technology

    2000-01-01

    in conducting a cognitive task analysis . The conduct of a cognitive task analysis is costly and labor intensive. As a result, a few computerized aids...evaluation of a computerized aid, specifically CAT-HCI (Cognitive Analysis Tool - Human Computer Interface), for the conduct of a detailed cognitive task analysis . A

  6. The mission events graphic generator software: A small tool with big results

    NASA Technical Reports Server (NTRS)

    Lupisella, Mark; Leibee, Jack; Scaffidi, Charles

    1993-01-01

    Utilization of graphics has long been a useful methodology for many aspects of spacecraft operations. A personal computer based software tool that implements straight-forward graphics and greatly enhances spacecraft operations is presented. This unique software tool is the Mission Events Graphic Generator (MEGG) software which is used in support of the Hubble Space Telescope (HST) Project. MEGG reads the HST mission schedule and generates a graphical timeline.

  7. Economics of infection control surveillance technology: cost-effective or just cost?

    PubMed

    Furuno, Jon P; Schweizer, Marin L; McGregor, Jessina C; Perencevich, Eli N

    2008-04-01

    Previous studies have suggested that informatics tools, such as automated alert and decision support systems, may increase the efficiency and quality of infection control surveillance. However, little is known about the cost-effectiveness of these tools. We focus on 2 types of economic analyses that have utility in assessing infection control interventions (cost-effectiveness analysis and business-case analysis) and review the available literature on the economics of computerized infection control surveillance systems. Previous studies on the effectiveness of computerized infection control surveillance have been limited to assessments of whether these tools increase the sensitivity and specificity of surveillance over traditional methods. Furthermore, we identified only 2 studies that assessed the costs associated with computerized infection control surveillance. Thus, it remains unknown whether computerized infection control surveillance systems are cost-effective and whether use of these systems improves patient outcomes. The existing data are insufficient to allow for a summary conclusion on the cost-effectiveness of infection control surveillance technology. All future studies of computerized infection control surveillance systems should aim to collect outcomes and economic data to inform decision making and assist hospitals with completing business-cases analyses.

  8. Handwriting Characteristics among Secondary Students with and without Physical Disabilities: A Study with a Computerized Tool

    ERIC Educational Resources Information Center

    Li-Tsang, Cecilia W. P.; Au, Ricky K. C.; Chan, Michelle H. Y.; Chan, Lily W. L.; Lau, Gloria M. T.; Lo, T. K.; Leung, Howard W. H.

    2011-01-01

    The purpose of the present study was to investigate the handwriting characteristics of secondary school students with and without physical disabilities (PD). With the use of a computerized Chinese Handwriting Assessment Tool (CHAT), it was made possible to objectively assess and analyze in detail the handwriting characteristics of individual…

  9. An Assistive Computerized Learning Environment for Distance Learning Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Klemes, Joel; Epstein, Alit; Zuker, Michal; Grinberg, Nira; Ilovitch, Tamar

    2006-01-01

    The current study examines how a computerized learning environment assists students with learning disabilities (LD) enrolled in a distance learning course at the Open University of Israel. The technology provides computer display of the text, synchronized with auditory output and accompanied by additional computerized study skill tools which…

  10. Processing And Display Of Medical Three Dimensional Arrays Of Numerical Data Using Octree Encoding

    NASA Astrophysics Data System (ADS)

    Amans, Jean-Louis; Darier, Pierre

    1986-05-01

    imaging modalities such as X-Ray computerized Tomography (CT), Nuclear Medecine and Nuclear Magnetic Resonance can produce three-dimensional (3-D) arrays of numerical data of medical object internal structures. The analysis of 3-D data by synthetic generation of realistic images is an important area of computer graphics and imaging.

  11. The New Film Technologies: Computerized Video-Assisted Film Production.

    ERIC Educational Resources Information Center

    Mott, Donald R.

    Over the past few years, video technology has been used to assist film directors after they have shot a scene, to control costs, and to create special effects, especially computer assisted graphics. At present, a computer based editing system called "Film 5" combines computer technology and video tape with film to save as much as 50% of…

  12. A powerful graphical pulse sequence programming tool for magnetic resonance imaging.

    PubMed

    Jie, Shen; Ying, Liu; Jianqi, Li; Gengying, Li

    2005-12-01

    A powerful graphical pulse sequence programming tool has been designed for creating magnetic resonance imaging (MRI) applications. It allows rapid development of pulse sequences in graphical mode (allowing for the visualization of sequences), and consists of three modules which include a graphical sequence editor, a parameter management module and a sequence compiler. Its key features are ease to use, flexibility and hardware independence. When graphic elements are combined with a certain text expressions, the graphical pulse sequence programming is as flexible as text-based programming tool. In addition, a hardware-independent design is implemented by using the strategy of two step compilations. To demonstrate the flexibility and the capability of this graphical sequence programming tool, a multi-slice fast spin echo experiment is performed on our home-made 0.3 T permanent magnet MRI system.

  13. Critical factors influencing physicians' intention to use computerized clinical practice guidelines: an integrative model of activity theory and the technology acceptance model.

    PubMed

    Hsiao, Ju-Ling; Chen, Rai-Fu

    2016-01-16

    With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p < 0.001), organizational support (γ = 0.285, p < 0.001), perceived usefulness of computerized clinical practice guidelines (γ = 0.219, p < 0.05), and social influence (γ = 0.213, p < 0.05) were critical factors influencing physicians' intention to use computerized clinical practice guidelines, and these factors can explain 68.6 % of the variance in intention to use computerized clinical practice guidelines. This study confirmed that some subject (human) factors, environment (organization) factors, tool (technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.

  14. Interactive graphic editing tools in bioluminescent imaging simulation

    NASA Astrophysics Data System (ADS)

    Li, Hui; Tian, Jie; Luo, Jie; Wang, Ge; Cong, Wenxiang

    2005-04-01

    It is a challenging task to accurately describe complicated biological tissues and bioluminescent sources in bioluminescent imaging simulation. Several graphic editing tools have been developed to efficiently model each part of the bioluminescent simulation environment and to interactively correct or improve the initial models of anatomical structures or bioluminescent sources. There are two major types of graphic editing tools: non-interactive tools and interactive tools. Geometric building blocks (i.e. regular geometric graphics and superquadrics) are applied as non-interactive tools. To a certain extent, complicated anatomical structures and bioluminescent sources can be approximately modeled by combining a sufficient large number of geometric building blocks with Boolean operators. However, those models are too simple to describe the local features and fine changes in 2D/3D irregular contours. Therefore, interactive graphic editing tools have been developed to facilitate the local modifications of any initial surface model. With initial models composed of geometric building blocks, interactive spline mode is applied to conveniently perform dragging and compressing operations on 2D/3D local surface of biological tissues and bioluminescent sources inside the region/volume of interest. Several applications of the interactive graphic editing tools will be presented in this article.

  15. Mousetrap: An integrated, open-source mouse-tracking package.

    PubMed

    Kieslich, Pascal J; Henninger, Felix

    2017-10-01

    Mouse-tracking - the analysis of mouse movements in computerized experiments - is becoming increasingly popular in the cognitive sciences. Mouse movements are taken as an indicator of commitment to or conflict between choice options during the decision process. Using mouse-tracking, researchers have gained insight into the temporal development of cognitive processes across a growing number of psychological domains. In the current article, we present software that offers easy and convenient means of recording and analyzing mouse movements in computerized laboratory experiments. In particular, we introduce and demonstrate the mousetrap plugin that adds mouse-tracking to OpenSesame, a popular general-purpose graphical experiment builder. By integrating with this existing experimental software, mousetrap allows for the creation of mouse-tracking studies through a graphical interface, without requiring programming skills. Thus, researchers can benefit from the core features of a validated software package and the many extensions available for it (e.g., the integration with auxiliary hardware such as eye-tracking, or the support of interactive experiments). In addition, the recorded data can be imported directly into the statistical programming language R using the mousetrap package, which greatly facilitates analysis. Mousetrap is cross-platform, open-source and available free of charge from https://github.com/pascalkieslich/mousetrap-os .

  16. Measurement and Validation of Bidirectional Reflectance of Space Shuttle and Space Station Materials for Computerized Lighting Models

    NASA Technical Reports Server (NTRS)

    Fletcher, Lauren E.; Aldridge, Ann M.; Wheelwright, Charles; Maida, James

    1997-01-01

    Task illumination has a major impact on human performance: What a person can perceive in his environment significantly affects his ability to perform tasks, especially in space's harsh environment. Training for lighting conditions in space has long depended on physical models and simulations to emulate the effect of lighting, but such tests are expensive and time-consuming. To evaluate lighting conditions not easily simulated on Earth, personnel at NASA Johnson Space Center's (JSC) Graphics Research and Analysis Facility (GRAF) have been developing computerized simulations of various illumination conditions using the ray-tracing program, Radiance, developed by Greg Ward at Lawrence Berkeley Laboratory. Because these computer simulations are only as accurate as the data used, accurate information about the reflectance properties of materials and light distributions is needed. JSC's Lighting Environment Test Facility (LETF) personnel gathered material reflectance properties for a large number of paints, metals, and cloths used in the Space Shuttle and Space Station programs, and processed these data into reflectance parameters needed for the computer simulations. They also gathered lamp distribution data for most of the light sources used, and validated the ability to accurately simulate lighting levels by comparing predictions with measurements for several ground-based tests. The result of this study is a database of material reflectance properties for a wide variety of materials, and lighting information for most of the standard light sources used in the Shuttle/Station programs. The combination of the Radiance program and GRAF's graphics capability form a validated computerized lighting simulation capability for NASA.

  17. Applications of graphics to support a testbed for autonomous space vehicle operations

    NASA Technical Reports Server (NTRS)

    Schmeckpeper, K. R.; Aldridge, J. P.; Benson, S.; Horner, S.; Kullman, A.; Mulder, T.; Parrott, W.; Roman, D.; Watts, G.; Bochsler, Daniel C.

    1989-01-01

    Researchers describe their experience using graphics tools and utilities while building an application, AUTOPS, that uses a graphical Machintosh (TM)-like interface for the input and display of data, and animation graphics to enhance the presentation of results of autonomous space vehicle operations simulations. AUTOPS is a test bed for evaluating decisions for intelligent control systems for autonomous vehicles. Decisions made by an intelligent control system, e.g., a revised mission plan, might be displayed to the user in textual format or he can witness the effects of those decisions via out of window graphics animations. Although a textual description conveys essentials, a graphics animation conveys the replanning results in a more convincing way. Similarily, iconic and menu-driven screen interfaces provide the user with more meaningful options and displays. Presented here are experiences with the SunView and TAE Plus graphics tools used for interface design, and the Johnson Space Center Interactive Graphics Laboratory animation graphics tools used for generating out out of the window graphics.

  18. [Representation of knowledge in respiratory medicine: ontology should help the coding process].

    PubMed

    Blanc, F-X; Baneyx, A; Charlet, J; Housset, B

    2010-09-01

    Access to medical knowledge is a major issue for health professionals and requires the development of terminologies. The objective of the reported work was to construct an ontology of respiratory medicine, i.e. an organized and formalized terminology composed by specific knowledge. The purpose is to help the medico-economical coding process and to represent the relevant knowledge about the patient. Our researches cover the whole life cycle of an ontology, from the development of a methodology, to building it from texts, to its use in an operational system. A computerized tool, based on the ontology, allows both a medico-economical coding and a graphical medical one. This second one will be used to index hospital reports. Our ontology counts 1913 concepts and contains all the knowledge included in the PMSI part of the SPLF thesaurus. Our tool has been evaluated and showed a recall of 80% and an accuracy of 85% regarding the medico-economical coding. The work presented in this paper justifies the approach that has been used. It must be continued on a large scale to validate our coding principles and the possibility of making enquiries on patient reports concerning clinical research. Copyright © 2010. Published by Elsevier Masson SAS.

  19. Role of Graphics Tools in the Learning Design Process

    ERIC Educational Resources Information Center

    Laisney, Patrice; Brandt-Pomares, Pascale

    2015-01-01

    This paper discusses the design activities of students in secondary school in France. Graphics tools are now part of the capacity of design professionals. It is therefore apt to reflect on their integration into the technological education. Has the use of intermediate graphical tools changed students' performance, and if so in what direction, in…

  20. Point-cloud-to-point-cloud technique on tool calibration for dental implant surgical path tracking

    NASA Astrophysics Data System (ADS)

    Lorsakul, Auranuch; Suthakorn, Jackrit; Sinthanayothin, Chanjira

    2008-03-01

    Dental implant is one of the most popular methods of tooth root replacement used in prosthetic dentistry. Computerize navigation system on a pre-surgical plan is offered to minimize potential risk of damage to critical anatomic structures of patients. Dental tool tip calibrating is basically an important procedure of intraoperative surgery to determine the relation between the hand-piece tool tip and hand-piece's markers. With the transferring coordinates from preoperative CT data to reality, this parameter is a part of components in typical registration problem. It is a part of navigation system which will be developed for further integration. A high accuracy is required, and this relation is arranged by point-cloud-to-point-cloud rigid transformations and singular value decomposition (SVD) for minimizing rigid registration errors. In earlier studies, commercial surgical navigation systems from, such as, BrainLAB and Materialize, have flexibility problem on tool tip calibration. Their systems either require a special tool tip calibration device or are unable to change the different tool. The proposed procedure is to use the pointing device or hand-piece to touch on the pivot and the transformation matrix. This matrix is calculated every time when it moves to the new position while the tool tip stays at the same point. The experiment acquired on the information of tracking device, image acquisition and image processing algorithms. The key success is that point-to-point-cloud requires only 3 post images of tool to be able to converge to the minimum errors 0.77%, and the obtained result is correct in using the tool holder to track the path simulation line displayed in graphic animation.

  1. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    PubMed

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  2. PC graphics generation and management tool for real-time applications

    NASA Technical Reports Server (NTRS)

    Truong, Long V.

    1992-01-01

    A graphics tool was designed and developed for easy generation and management of personal computer graphics. It also provides methods and 'run-time' software for many common artificial intelligence (AI) or expert system (ES) applications.

  3. Computer-based desktop system for surgical videotape editing.

    PubMed

    Vincent-Hamelin, E; Sarmiento, J M; de la Puente, J M; Vicente, M

    1997-05-01

    The educational role of surgical video presentations should be optimized by linking surgical images to graphic evaluation of indications, techniques, and results. We describe a PC-based video production system for personal editing of surgical tapes, according to the objectives of each presentation. The hardware requirement is a personal computer (100 MHz processor, 1-Gb hard disk, 16 Mb RAM) with a PC-to-TV/video transfer card plugged into a slot. Computer-generated numerical data, texts, and graphics are transformed into analog signals displayed on TV/video. A Genlock interface (a special interface card) synchronizes digital and analog signals, to overlay surgical images to electronic illustrations. The presentation is stored as digital information or recorded on a tape. The proliferation of multimedia tools is leading us to adapt presentations to the objectives of lectures and to integrate conceptual analyses with dynamic image-based information. We describe a system that handles both digital and analog signals, production being recorded on a tape. Movies may be managed in a digital environment, with either an "on-line" or "off-line" approach. System requirements are high, but handling a single device optimizes editing without incurring such complexity that management becomes impractical to surgeons. Our experience suggests that computerized editing allows linking surgical scientific and didactic messages on a single communication medium, either a videotape or a CD-ROM.

  4. Using a graphical programming language to write CAMAC/GPIB instrument drivers

    NASA Technical Reports Server (NTRS)

    Zambrana, Horacio; Johanson, William

    1991-01-01

    To reduce the complexities of conventional programming, graphical software was used in the development of instrumentation drivers. The graphical software provides a standard set of tools (graphical subroutines) which are sufficient to program the most sophisticated CAMAC/GPIB drivers. These tools were used and instrumentation drivers were successfully developed for operating CAMAC/GPIB hardware from two different manufacturers: LeCroy and DSP. The use of these tools is presented for programming a LeCroy A/D Waveform Analyzer.

  5. LIBRE Stick Figure Tool: A Graphic Organizer to Foster Self-Regulated Social Cognitive Problem Solving

    ERIC Educational Resources Information Center

    Guerra, Norma S.

    2009-01-01

    Graphic organizers are powerful visual tools. The representation provides dimension and relationship to ideas and a framework for organization and elaboration. The LIBRE Stick Figure Tool is a graphic organizer for the problem-solving application of the LIBRE Model counseling approach. It resembles a "stick person" and offers the teacher and…

  6. An Approach towards Ultrasound Kidney Cysts Detection using Vector Graphic Image Analysis

    NASA Astrophysics Data System (ADS)

    Mahmud, Wan Mahani Hafizah Wan; Supriyanto, Eko

    2017-08-01

    This study develops new approach towards detection of kidney ultrasound image for both with single cyst as well as multiple cysts. 50 single cyst images and 25 multiple cysts images were used to test the developed algorithm. Steps involved in developing this algorithm were vector graphic image formation and analysis, thresholding, binarization, filtering as well as roundness test. Performance evaluation to 50 single cyst images gave accuracy of 92%, while for multiple cysts images, the accuracy was about 86.89% when tested to 25 multiple cysts images. This developed algorithm may be used in developing a computerized system such as computer aided diagnosis system to help medical experts in diagnosis of kidney cysts.

  7. Evaluating Texts for Graphical Literacy Instruction: The Graphic Rating Tool

    ERIC Educational Resources Information Center

    Roberts, Kathryn L.; Brugar, Kristy A.; Norman, Rebecca R.

    2015-01-01

    In this article, we present the Graphical Rating Tool (GRT), which is designed to evaluate the graphical devices that are commonly found in content-area, non-fiction texts, in order to identify books that are well suited for teaching about those devices. We also present a "best of" list of science and social studies books, which includes…

  8. Decision-support information system to manage mass casualty incidents at a level 1 trauma center.

    PubMed

    Bar-El, Yaron; Tzafrir, Sara; Tzipori, Idan; Utitz, Liora; Halberthal, Michael; Beyar, Rafael; Reisner, Shimon

    2013-12-01

    Mass casualty incidents are probably the greatest challenge to a hospital. When such an event occurs, hospitals are required to instantly switch from their routine activity to conditions of great uncertainty and confront needs that exceed resources. We describe an information system that was uniquely designed for managing mass casualty events. The web-based system is activated when a mass casualty event is declared; it displays relevant operating procedures, checklists, and a log book. The system automatically or semiautomatically initiates phone calls and public address announcements. It collects real-time data from computerized clinical and administrative systems in the hospital, and presents them to the managing team in a clear graphic display. It also generates periodic reports and summaries of available or scarce resources that are sent to predefined recipients. When the system was tested in a nationwide exercise, it proved to be an invaluable tool for informed decision making in demanding and overwhelming situations such as mass casualty events.

  9. Enhancing GDOT's Computerized Pavement Condition Evaluation System for Pavement Condition Survey

    DOT National Transportation Integrated Search

    2017-09-01

    The Computerized Pavement Condition Evaluation System (COPACES) is a software tool that has been used by the Georgia Department of Transportation (GDOT) for its statewide pavement condition survey since the late 1990s. The previous version was releas...

  10. Living Color Frame System: PC graphics tool for data visualization

    NASA Technical Reports Server (NTRS)

    Truong, Long V.

    1993-01-01

    Living Color Frame System (LCFS) is a personal computer software tool for generating real-time graphics applications. It is highly applicable for a wide range of data visualization in virtual environment applications. Engineers often use computer graphics to enhance the interpretation of data under observation. These graphics become more complicated when 'run time' animations are required, such as found in many typical modern artificial intelligence and expert systems. Living Color Frame System solves many of these real-time graphics problems.

  11. Distributed Computerized Catalog System

    NASA Technical Reports Server (NTRS)

    Borgen, Richard L.; Wagner, David A.

    1995-01-01

    DarkStar Distributed Catalog System describes arbitrary data objects in unified manner, providing end users with versatile, yet simple search mechanism for locating and identifying objects. Provides built-in generic and dynamic graphical user interfaces. Design of system avoids some of problems of standard DBMS, and system provides more flexibility than do conventional relational data bases, or object-oriented data bases. Data-collection lattice partly hierarchical representation of relationships among collections, subcollections, and data objects.

  12. [Computerized acquisition and elaboration of clinical data in Rheumatology during ten years: state of art and prospectives

    PubMed

    Troise Rioda, W.; Nervetti, A.

    2001-01-01

    The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.

  13. Web-based automation of green building rating index and life cycle cost analysis

    NASA Astrophysics Data System (ADS)

    Shahzaib Khan, Jam; Zakaria, Rozana; Aminuddin, Eeydzah; IzieAdiana Abidin, Nur; Sahamir, Shaza Rina; Ahmad, Rosli; Nafis Abas, Darul

    2018-04-01

    Sudden decline in financial markets and economic meltdown has slow down adaptation and lowered interest of investors towards green certified buildings due to their higher initial costs. Similarly, it is essential to fetch investor’s attention towards more development of green buildings through automated tools for the construction projects. Though, historical dearth is found on the automation of green building rating tools that brings up an essential gap to develop an automated analog computerized programming tool. This paper present a proposed research aim to develop an integrated web-based automated analog computerized programming that applies green building rating assessment tool, green technology and life cycle cost analysis. It also emphasizes to identify variables of MyCrest and LCC to be integrated and developed in a framework then transformed into automated analog computerized programming. A mix methodology of qualitative and quantitative survey and its development portray the planned to carry MyCrest-LCC integration to an automated level. In this study, the preliminary literature review enriches better understanding of Green Building Rating Tools (GBRT) integration to LCC. The outcome of this research is a pave way for future researchers to integrate other efficient tool and parameters that contributes towards green buildings and future agendas.

  14. Performances on the CogState and Standard Neuropsychological Batteries Among HIV Patients Without Dementia

    PubMed Central

    Overton, Edgar Turner; Kauwe, John S.K.; Paul, Rob; Tashima, Karen; Tate, David F.; Patel, Pragna; Carpenter, Chuck; Patty, David; Brooks, John T.; Clifford, David B

    2013-01-01

    HIV-associated neurocognitive disorders (HAND) remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (p<0.01). These data confirm previous correlation data with the computerized battery, yet illustrate remaining challenges for neurocognitive screening. PMID:21877204

  15. Simulation studies promote technological development of radiofrequency phased array hyperthermia.

    PubMed

    Wust, P; Seebass, M; Nadobny, J; Deuflhard, P; Mönich, G; Felix, R

    1996-01-01

    A treatment planning program package for radiofrequency hyperthermia has been developed. It consists of software modules for processing three-dimensional computerized tomography (CT) data sets, manual segmentation, generation of tetrahedral grids, numerical calculation and optimisation of three-dimensional E field distributions using a volume surface integral equation algorithm as well as temperature distributions using an adaptive multilevel finite-elements code, and graphical tools for simultaneous representation of CT data and simulation results. Heat treatments are limited by hot spots in healthy tissues caused by E field maxima at electrical interfaces (bone/muscle). In order to reduce or avoid hot spots suitable objective functions are derived from power deposition patterns and temperature distributions, and are utilised to optimise antenna parameters (phases, amplitudes). The simulation and optimisation tools have been applied to estimate the improvements that could be reached by upgrades of the clinically used SIGMA-60 applicator (consisting of a single ring of four antenna pairs). The investigated upgrades are increased number of antennas and channels (triple-ring of 3 x 8 antennas and variation of antenna inclination. Significant improvement of index temperatures (1-2 degrees C) is achieved by upgrading the single ring to a triple ring with free phase selection for every antenna or antenna pair. Antenna amplitudes and inclinations proved as less important parameters.

  16. Special Education Curriculum (Computerized IEP Catalog).

    ERIC Educational Resources Information Center

    Garland Independent School District, TX.

    This special education curriculum, developed by the Garland (Texas) Independent School District, outlines the basic tools for preparing an Individual Educational Plan (IEP) for each handicapped student. The curricular information is organized and coded to facilitate computerized printing of the IEP. The document begins with a list of 13…

  17. Automated RTOP Management System

    NASA Technical Reports Server (NTRS)

    Hayes, P.

    1984-01-01

    The structure of NASA's Office of Aeronautics and Space Technology electronic information system network from 1983 to 1985 is illustrated. The RTOP automated system takes advantage of existing hardware, software, and expertise, and provides: (1) computerized cover sheet and resources forms; (2) electronic signature and transmission; (3) a data-based information system; (4) graphics; (5) intercenter communications; (6) management information; and (7) text editing. The system is coordinated with Headquarters efforts in codes R,E, and T.

  18. 3D Graphics Through the Internet: A "Shoot-Out"

    NASA Technical Reports Server (NTRS)

    Watson, Val; Lasinski, T. A. (Technical Monitor)

    1995-01-01

    3D graphics through the Internet needs to move beyond the current lowest common denominator of pre-computed movies, which consume bandwidth and are non-interactive. Panelists will demonstrate and compare 3D graphical tools for accessing, analyzing, and collaborating on information through the Internet and World-wide web. The "shoot-out" will illustrate which tools are likely to be the best for the various types of information, including dynamic scientific data, 3-D objects, and virtual environments. The goal of the panel is to encourage more effective use of the Internet by encouraging suppliers and users of information to adopt the next generation of graphical tools.

  19. Computerized system for assessing heart rate variability.

    PubMed

    Frigy, A; Incze, A; Brânzaniuc, E; Cotoi, S

    1996-01-01

    The principal theoretical, methodological and clinical aspects of heart rate variability (HRV) analysis are reviewed. This method has been developed over the last 10 years as a useful noninvasive method of measuring the activity of the autonomic nervous system. The main components and the functioning of the computerized rhythm-analyzer system developed by our team are presented. The system is able to perform short-term (maximum 20 minutes) time domain HRV analysis and statistical analysis of the ventricular rate in any rhythm, particularly in atrial fibrillation. The performances of our system are demonstrated by using the graphics (RR histograms, delta RR histograms, RR scattergrams) and the statistical parameters resulted from the processing of three ECG recordings. These recordings are obtained from a normal subject, from a patient with advanced heart failure, and from a patient with atrial fibrillation.

  20. Computerized Spiral Analysis Using the iPad

    PubMed Central

    Sisti, Jonathan A.; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L.A.; Gupta, Vivek P.; Bandin, Alexander J.; Yu, Qiping; Pullman, Seth L.

    2017-01-01

    Background Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson’s disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. New Method We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. Results The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. Comparison with Existing Method While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. Conclusions The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. PMID:27840146

  1. Computerized spiral analysis using the iPad.

    PubMed

    Sisti, Jonathan A; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L A; Gupta, Vivek P; Bandin, Alexander J; Yu, Qiping; Pullman, Seth L

    2017-01-01

    Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson's disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.

    PubMed

    Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio

    2014-08-01

    To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Computerized symptom and quality-of-life assessment for patients with cancer part I: development and pilot testing.

    PubMed

    Berry, Donna L; Trigg, Lisa J; Lober, William B; Karras, Bryant T; Galligan, Mary L; Austin-Seymour, Mary; Martin, Stephanie

    2004-09-01

    To develop and test an innovative computerized symptom and quality-of-life (QOL) assessment for patients with cancer who are evaluated for and treated with radiation therapy. Descriptive, longitudinal prototype development and cross-sectional clinical data. Department of radiation oncology in an urban, academic medical center. 101 outpatients who were evaluated for radiation therapy, able to communicate in English (or through one of many interpreters available at the University of Washington), and competent to understand the study information and give informed consent. Six clinicians caring for the patients in the sample were enrolled. Iterative prototype development was conducted using a standing focus group of clinicians. The software was developed based on survey markup language and implemented in a wireless, Web-based format. Patient participants completed the computerized assessment prior to consultation with the radiation physician. Graphical output pages with flagged areas of symptom distress or troublesome QOL issues were made available to consulting physicians and nurses. Pain intensity, symptoms, QOL, and demographics. Computerized versions of a 0 to 10 Pain Intensity Numerical Scale (PINS), Symptom Distress Scale, and Short Form-8. Focus group recommendations included clinician priorities of brevity, flexibility, and simplicity for both input interface and output and that the assessment output contain color graphic display. Patient participants included 45 women and 56 men with a mean age of 52.7 years (SD = 13.8). Fewer than half of the participants (40%) reported using a computer on a regular basis (weekly or daily). Completion time averaged 7.8 minutes (SD = 3.7). Moderate to high levels of distress were reported more often for fatigue, pain, and emotional issues than for other symptoms or concerns. Computerized assessment of cancer symptoms and QOL is technically possible and feasible in an ambulatory cancer clinic. A wireless, Web-based system facilitates access to results and data entry and retrieval. The symptom and QOL profiles of these patients new to radiation therapy were comparable to other samples of outpatients with cancer. The ability to capture an easily interpreted illustration of a patients symptom and QOL experience in less than 10 minutes is a potentially useful adjunct to traditional face-to-face interviewing. Ultimately, electronic patient-generated data could produce automated red flags directed to the most appropriate clinicians (e.g., nurse, pain specialist, social worker, nutritionist) for further evaluation. Such system enhancement could greatly facilitate oncology nurses coordination role in caring for complex patients with cancer.

  4. Methodologie experimentale pour evaluer les caracteristiques des plateformes graphiques avioniques

    NASA Astrophysics Data System (ADS)

    Legault, Vincent

    Within a context where the aviation industry intensifies the development of new visually appealing features and where time-to-market must be as short as possible, rapid graphics processing benchmarking in a certified avionics environment becomes an important issue. With this work we intend to demonstrate that it is possible to deploy a high-performance graphics application on an avionics platform that uses certified graphical COTS components. Moreover, we would like to bring to the avionics community a methodology which will allow developers to identify the needed elements for graphics system optimisation and provide them tools that can measure the complexity of this type of application and measure the amount of resources to properly scale a graphics system according to their needs. As far as we know, no graphics performance profiling tool dedicated to critical embedded architectures has been proposed. We thus had the idea of implementing a specialized benchmarking tool that would be an appropriate and effective solution to this problem. Our solution resides in the extraction of the key graphics specifications from an inherited application to use them afterwards in a 3D image generation application.

  5. Regulatory issues for computerized electrocardiographic devices.

    PubMed

    Muni, Neal I; Ho, Charles; Mallis, Elias

    2004-01-01

    Computerized electrocardiogram (ECG) devices are regulated in the U.S. by the FDA Center for Devices and Radiological Health (CDRH). This article aims to highlight the salient points of the FDA regulatory review process, including the important distinction between a "tool" claim and a "clinical" claim in the intended use of a computerized ECG device. Specifically, a tool claim relates to the ability of the device to accurately measure a certain ECG parameter, such as T-wave alternans (TWA), while a clinical claim imputes a particular health hazard associated with the identified parameter, such as increased risk of ventricular tachyarrhythmia or sudden death. Given that both types of claims are equally important and receive the same regulatory scrutiny, the manufacturer of a new ECG diagnostic device should consider the distinction and regulatory pathways for approval between the two types of claims discussed in this paper.

  6. Operation ARA: A Computerized Learning Game that Teaches Critical Thinking and Scientific Reasoning

    ERIC Educational Resources Information Center

    Halpern, Diane F.; Millis, Keith; Graesser, Arthur C.; Butler, Heather; Forsyth, Carol; Cai, Zhiqiang

    2012-01-01

    Operation ARA (Acquiring Research Acumen) is a computerized learning game that teaches critical thinking and scientific reasoning. It is a valuable learning tool that utilizes principles from the science of learning and serious computer games. Students learn the skills of scientific reasoning by engaging in interactive dialogs with avatars. They…

  7. Mixed results in the safety performance of computerized physician order entry.

    PubMed

    Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C

    2010-04-01

    Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.

  8. Making Conjectures in Dynamic Geometry: The Potential of a Particular Way of Dragging

    ERIC Educational Resources Information Center

    Mariotti, Maria Alessandra; Baccaglini-Frank, Anna

    2011-01-01

    When analyzing what has changed in the geometry scenario with the advent of dynamic geometry systems (DGS), one can notice a transition from the traditional graphic environment made of paper-and-pencil, and the classical construction tools like the ruler and compass, to a virtual graphic space, made of a computer screen, graphical tools that are…

  9. Data Analysis with Graphical Models: Software Tools

    NASA Technical Reports Server (NTRS)

    Buntine, Wray L.

    1994-01-01

    Probabilistic graphical models (directed and undirected Markov fields, and combined in chain graphs) are used widely in expert systems, image processing and other areas as a framework for representing and reasoning with probabilities. They come with corresponding algorithms for performing probabilistic inference. This paper discusses an extension to these models by Spiegelhalter and Gilks, plates, used to graphically model the notion of a sample. This offers a graphical specification language for representing data analysis problems. When combined with general methods for statistical inference, this also offers a unifying framework for prototyping and/or generating data analysis algorithms from graphical specifications. This paper outlines the framework and then presents some basic tools for the task: a graphical version of the Pitman-Koopman Theorem for the exponential family, problem decomposition, and the calculation of exact Bayes factors. Other tools already developed, such as automatic differentiation, Gibbs sampling, and use of the EM algorithm, make this a broad basis for the generation of data analysis software.

  10. DspaceOgre 3D Graphics Visualization Tool

    NASA Technical Reports Server (NTRS)

    Jain, Abhinandan; Myin, Steven; Pomerantz, Marc I.

    2011-01-01

    This general-purpose 3D graphics visualization C++ tool is designed for visualization of simulation and analysis data for articulated mechanisms. Examples of such systems are vehicles, robotic arms, biomechanics models, and biomolecular structures. DspaceOgre builds upon the open-source Ogre3D graphics visualization library. It provides additional classes to support the management of complex scenes involving multiple viewpoints and different scene groups, and can be used as a remote graphics server. This software provides improved support for adding programs at the graphics processing unit (GPU) level for improved performance. It also improves upon the messaging interface it exposes for use as a visualization server.

  11. Flowfield computer graphics

    NASA Technical Reports Server (NTRS)

    Desautel, Richard

    1993-01-01

    The objectives of this research include supporting the Aerothermodynamics Branch's research by developing graphical visualization tools for both the branch's adaptive grid code and flow field ray tracing code. The completed research for the reporting period includes development of a graphical user interface (GUI) and its implementation into the NAS Flowfield Analysis Software Tool kit (FAST), for both the adaptive grid code (SAGE) and the flow field ray tracing code (CISS).

  12. Semantically Grounded Briefings

    DTIC Science & Technology

    2005-12-01

    cascading interface, mirroring the class inheritance of the ontologies. Clicking on one of these tools, like PowerPoint’s native autoshape tools...connections are their graphic templates. This determines the appearance of an instance of that concept. Any of PowerPoint’s native autoshapes , formatted...which can be any PowerPoint autoshape , group shape, or image • Identification of a modulated component of C’s graphic template. If C’s graphic

  13. Wood transportation systems-a spin-off of a computerized information and mapping technique

    Treesearch

    William W. Phillips; Thomas J. Corcoran

    1978-01-01

    A computerized mapping system originally developed for planning the control of the spruce budworm in Maine has been extended into a tool for planning road net-work development and optimizing transportation costs. A budgetary process and a mathematical linear programming routine are used interactively with the mapping and information retrieval capabilities of the system...

  14. The Child Well-Being Scales as a Clinical Tool and a Management Information System.

    ERIC Educational Resources Information Center

    Lyons, Peter; Doueck, Howard J.; Koster, Andrew J.; Witzky, Melissa K.; Kelly, Patricia L.

    1999-01-01

    Describes implementation of a computerized version of the Child Welfare League of America's Child Well-Being Scales by a family services agency in southern Ontario. Reviews results obtained from 172 families to illustrate the potential for using computerized risk assessment as an aid in clinical, supervisory, and management decision-making…

  15. Canadian adaptation of the Newest Vital Sign©, a health literacy assessment tool.

    PubMed

    Mansfield, Elizabeth D; Wahba, Rana; Gillis, Doris E; Weiss, Barry D; L'Abbé, Mary

    2018-04-25

    The Newest Vital Sign© (NVS) was developed in the USA to measure patient health literacy in clinical settings. We adapted the NVS for use in Canada, in English and French, and created a computerized version. Our objective was to evaluate the reliability of the Canadian NVS as a self-administered computerized tool. We used a randomized crossover design with a washout period of 3-4 weeks to compare health literacy scores obtained using the computerized version with scores obtained using the standard interviewer-administered NVS. ANOVA models and McNemar's tests assessed differences in outcomes assessed with each version of the NVS and order effects of the testing. Participants were recruited from multicultural catchment areas in Ontario and Nova Scotia. English- and French-speaking adults aged 18 years or older. A total of 180 (81 %) of the 222 adults (112 English/110 French) initially recruited completed both the interviewer-NVS and computer-NVS. Scores for those who completed both assessments ranged from 0 to 6 with a mean of 3·63 (sd 2·11) for the computerized NVS and 3·41 (sd 2·21) for the interview-administered NVS. Few (n 18; seven English, eleven French) participants' health literacy assessments differed between the two versions. Overall, the computerized Canadian NVS performed as well as the interviewer-administered version for assessing health literacy levels of English- and French-speaking participants. This Canadian adaptation of the NVS provides Canadian researchers and public health practitioners with an easily administered health literacy assessment tool that can be used to address the needs of Canadians across health literacy levels and ultimately improve health outcomes.

  16. Graphic Design Is Not a Medium.

    ERIC Educational Resources Information Center

    Gruber, John Edward, Jr.

    2001-01-01

    Discusses graphic design and reviews its development from analog processes to a digital tool with the use of computers. Topics include graphical user interfaces; the need for visual communication concepts; transmedia as opposed to repurposing; and graphic design instruction in higher education. (LRW)

  17. GRASP - A Prototype Interactive Graphic Sawing Program - (Forest Products Journal)

    Treesearch

    Luis G. Occeña; Daniel L. Schmoldt

    1996-01-01

    A versatile microcomputer-based interactive graphics sawing program has been developed as a tool for modeling various hardwood processes, from bucking and topping to log sawing, lumber edging, secondary processing, and even veneering. The microcomputer platform makes the tool affordable and accessible. A solid modeling basis provides the tool with a sound geometrical...

  18. GRASP - A Prototype Interactive Graphic Sawing Program - (MU-IE Technical Report)

    Treesearch

    Luis G. Occeña; Daniel L. Schmoldt

    1995-01-01

    A versatile microcomputer-based interactive graphics program has been developed as a tool for modeling various hardwood processes, from bucking and topping to log sawing, lumber edging, secondary processing, even veneering. The microcomputer platform makes the tool affordable and accessible.A solid modeling basis provides the tool with a sound geometrical and...

  19. Creating Interactive Graphical Overlays in the Advanced Weather Interactive Processing System (AWIPS) Using Shapefiles and DGM Files

    NASA Technical Reports Server (NTRS)

    Barrett, Joe H., III; Lafosse, Richard; Hood, Doris; Hoeth, Brian

    2007-01-01

    Graphical overlays can be created in real-time in the Advanced Weather Interactive Processing System (AWIPS) using shapefiles or DARE Graphics Metafile (DGM) files. This presentation describes how to create graphical overlays on-the-fly for AWIPS, by using two examples of AWIPS applications that were created by the Applied Meteorology Unit (AMU). The first example is the Anvil Threat Corridor Forecast Tool, which produces a shapefile that depicts a graphical threat corridor of the forecast movement of thunderstorm anvil clouds, based on the observed or forecast upper-level winds. This tool is used by the Spaceflight Meteorology Group (SMG) and 45th Weather Squadron (45 WS) to analyze the threat of natural or space vehicle-triggered lightning over a location. The second example is a launch and landing trajectory tool that produces a DGM file that plots the ground track of space vehicles during launch or landing. The trajectory tool can be used by SMG and the 45 WS forecasters to analyze weather radar imagery along a launch or landing trajectory. Advantages of both file types will be listed.

  20. On line instrument systems for monitoring steam turbogenerators

    NASA Astrophysics Data System (ADS)

    Clapis, A.; Giorgetti, G.; Lapini, G. L.; Benanti, A.; Frigeri, C.; Gadda, E.; Mantino, E.

    A computerized real time data acquisition and data processing for the diagnosis of malfunctioning of steam turbogenerator systems is described. Pressure, vibration and temperature measurements are continuously collected from standard or special sensors including startup or stop events. The architecture of the monitoring system is detailed. Examples of the graphics output are presented. It is shown that such a system allows accurate diagnosis and the possibility of creating a data bank to describe the dynamic characteristics of the machine park.

  1. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  2. Incorporating client-server database architecture and graphical user interface into outpatient medical records.

    PubMed Central

    Fiacco, P. A.; Rice, W. H.

    1991-01-01

    Computerized medical record systems require structured database architectures for information processing. However, the data must be able to be transferred across heterogeneous platform and software systems. Client-Server architecture allows for distributive processing of information among networked computers and provides the flexibility needed to link diverse systems together effectively. We have incorporated this client-server model with a graphical user interface into an outpatient medical record system, known as SuperChart, for the Department of Family Medicine at SUNY Health Science Center at Syracuse. SuperChart was developed using SuperCard and Oracle SuperCard uses modern object-oriented programming to support a hypermedia environment. Oracle is a powerful relational database management system that incorporates a client-server architecture. This provides both a distributed database and distributed processing which improves performance. PMID:1807732

  3. Case Studies in Practical Career Guidance, Number 5: Computerized Vocational Information System Willowbrook High School, Villa Park, Illinois.

    ERIC Educational Resources Information Center

    Arutunian, Carol Ann

    The Computerized Vocational Information System (CVIS) at Willowbrook High School in Villa Park, Illinois, uses the computer as a tool to help each student explore a wide range of occupations and educational opportunities with some feedback from his own record of ability, achievement, and interest. Computer-based guidance systems are considered a…

  4. Plots, Calculations and Graphics Tools (PCG2). Software Transfer Request Presentation

    NASA Technical Reports Server (NTRS)

    Richardson, Marilou R.

    2010-01-01

    This slide presentation reviews the development of the Plots, Calculations and Graphics Tools (PCG2) system. PCG2 is an easy to use tool that provides a single user interface to view data in a pictorial, tabular or graphical format. It allows the user to view the same display and data in the Control Room, engineering office area, or remote sites. PCG2 supports extensive and regular engineering needs that are both planned and unplanned and it supports the ability to compare, contrast and perform ad hoc data mining over the entire domain of a program's test data.

  5. Patients were more consistent in randomized trial at prioritizing childbirth preferences using graphic-numeric than verbal formats.

    PubMed

    Eden, Karen B; Dolan, James G; Perrin, Nancy A; Kocaoglu, Dundar; Anderson, Nicholas; Case, James; Guise, Jeanne-Marie

    2009-04-01

    We developed an evidence-based decision aid to help women with a prior cesarean to prioritize their childbirth preferences related to a future birth. Because there was uncertainty about which scale format would assist the patients in being most consistent in prioritizing preferences in a multiattribute decision model, we compared a graphic-numeric scale with a text-anchored scale. Ninety-six postnatal women with a prior cesarean were randomized to use 1 of 2 preference scale formats in a computerized childbirth decision aid. We measured the level of inconsistency (intransitivity) when patients prioritized their childbirth preferences and clarity of values before and after using the decision aid. When the trade-offs involved risk, women were more consistent when using graphic-numeric than text-anchored formats (P=0.015). They prioritized safety to their baby as 4 times more important than any other decision factor including safety to self. Both groups reduced unclear childbirth values over time (P<0.001). Women who over-used the extreme ends of the scale when evaluating risk were more likely to be inconsistent (P<0.001). Patients were more consistent in making trade-offs involving risk using graphic-numeric formats than text-anchored formats to measure patient preferences.

  6. Designer: A Knowledge-Based Graphic Design Assistant.

    ERIC Educational Resources Information Center

    Weitzman, Louis

    This report describes Designer, an interactive tool for assisting with the design of two-dimensional graphic interfaces for instructional systems. The system, which consists of a color graphics interface to a mathematical simulation, provides enhancements to the Graphics Editor component of Steamer (a computer-based training system designed to aid…

  7. Engineering Graphics Educational Outcomes for the Global Engineer: An Update

    ERIC Educational Resources Information Center

    Barr, R. E.

    2012-01-01

    This paper discusses the formulation of educational outcomes for engineering graphics that span the global enterprise. Results of two repeated faculty surveys indicate that new computer graphics tools and techniques are now the preferred mode of engineering graphical communication. Specifically, 3-D computer modeling, assembly modeling, and model…

  8. Writing from behind the Fence: Incarcerated Youths and a Graphic Novel on HIV/AIDS

    ERIC Educational Resources Information Center

    Gavigan, Karen; Albright, Kendra

    2015-01-01

    Graphic novels are an increasingly popular format that educators can use as a tool to teach reading and writing skills across the K-12 curriculum. This article describes a project in which incarcerated youths collaborated with a graphic illustrator to create a graphic novel about teens dealing with issues related to HIV/AIDS. The graphic novel is…

  9. A Monthly Water-Balance Model Driven By a Graphical User Interface

    USGS Publications Warehouse

    McCabe, Gregory J.; Markstrom, Steven L.

    2007-01-01

    This report describes a monthly water-balance model driven by a graphical user interface, referred to as the Thornthwaite monthly water-balance program. Computations of monthly water-balance components of the hydrologic cycle are made for a specified location. The program can be used as a research tool, an assessment tool, and a tool for classroom instruction.

  10. The graphics calculator in mathematics education: A critical review of recent research

    NASA Astrophysics Data System (ADS)

    Penglase, Marina; Arnold, Stephen

    1996-04-01

    The graphics calculator, sometimes referred to as the "super calculator," has sparked great interest among mathematics educators. Considered by many to be a tool which has the potential to revolutionise mathematics education, a significant amount of research has been conducted into its effectiveness as a tool for instruction and learning within precalculus and calculus courses, specifically in the study of functions, graphing and modelling. Some results suggest that these devices (a) can facilitate the learning of functions and graphing concepts and the development of spatial visualisation skills; (b) promote mathematical investigation and exploration; and (c) encourage a shift in emphasis from algebraic manipulation and proof to graphical investigation and examination of the relationship between graphical, algebraic and geometric representations. Other studies, however, indicate that there is still a need for manipulative techniques in the learning of function and graphing concepts, that the use of graphics calculators may not facilitate the learning of particular precalculus topics, and that some "de-skilling" may occur, especially among males. It is the contention of this paper, however, that much of the research in this new and important field fails to provide clear guidance or even to inform debate in adequate ways regarding the role of graphics calculators in mathematics teaching and learning. By failing to distinguish the role of the tool from that of the instructional process, many studies reviewed could be more appropriately classified as "program evaluations" rather than as research on the graphics calculator per se. Further, claims regarding the effectiveness of the graphics calculator as a tool for learning frequently fail to recognise that judgments of effectiveness result directly from existing assumptions regarding both assessment practice and student "achievement."

  11. PC Software graphics tool for conceptual design of space/planetary electrical power systems

    NASA Technical Reports Server (NTRS)

    Truong, Long V.

    1995-01-01

    This paper describes the Decision Support System (DSS), a personal computer software graphics tool for designing conceptual space and/or planetary electrical power systems. By using the DSS, users can obtain desirable system design and operating parameters, such as system weight, electrical distribution efficiency, and bus power. With this tool, a large-scale specific power system was designed in a matter of days. It is an excellent tool to help designers make tradeoffs between system components, hardware architectures, and operation parameters in the early stages of the design cycle. The DSS is a user-friendly, menu-driven tool with online help and a custom graphical user interface. An example design and results are illustrated for a typical space power system with multiple types of power sources, frequencies, energy storage systems, and loads.

  12. An information retrieval system for computerized patient records in the context of a daily hospital practice: the example of the Léon Bérard Cancer Center (France).

    PubMed

    Biron, P; Metzger, M H; Pezet, C; Sebban, C; Barthuet, E; Durand, T

    2014-01-01

    A full-text search tool was introduced into the daily practice of Léon Bérard Center (France), a health care facility devoted to treatment of cancer. This tool was integrated into the hospital information system by the IT department having been granted full autonomy to improve the system. To describe the development and various uses of a tool for full-text search of computerized patient records. The technology is based on Solr, an open-source search engine. It is a web-based application that processes HTTP requests and returns HTTP responses. A data processing pipeline that retrieves data from different repositories, normalizes, cleans and publishes it to Solr, was integrated in the information system of the Leon Bérard center. The IT department developed also user interfaces to allow users to access the search engine within the computerized medical record of the patient. From January to May 2013, 500 queries were launched per month by an average of 140 different users. Several usages of the tool were described, as follows: medical management of patients, medical research, and improving the traceability of medical care in medical records. The sensitivity of the tool for detecting the medical records of patients diagnosed with both breast cancer and diabetes was 83.0%, and its positive predictive value was 48.7% (gold standard: manual screening by a clinical research assistant). The project demonstrates that the introduction of full-text-search tools allowed practitioners to use unstructured medical information for various purposes.

  13. The Development of a Concept Inventory for Engineering Graphics

    ERIC Educational Resources Information Center

    Nozaki, Steven Yasuto

    2017-01-01

    Graphics education has been a central component in the engineering course of study. As technology advances, so have the methods in which graphics are expressed and practiced. Though the of media of graphics education have evolved, the concepts of the field remain relatively consistent. Tools are needed to measure students' comprehension,…

  14. Graphics Tablet Technology in Second Year Thermal Engineering Teaching

    ERIC Educational Resources Information Center

    Carrillo, Antonio; Cejudo, José Manuel; Domínguez, Fernando; Rodríguez, Eduardo

    2013-01-01

    Graphics tablet technology is well known in markets such as manufacturing, graphics arts and design but it has not yet found widespread acceptance for university teaching. A graphics tablet is an affordable teaching tool that combines the best features from traditional and new media. It allows developing a progressive, interactive lecture (as a…

  15. Evaluation of a computerized aid for creating human behavioral representations of human-computer interaction.

    PubMed

    Williams, Kent E; Voigt, Jeffrey R

    2004-01-01

    The research reported herein presents the results of an empirical evaluation that focused on the accuracy and reliability of cognitive models created using a computerized tool: the cognitive analysis tool for human-computer interaction (CAT-HCI). A sample of participants, expert in interacting with a newly developed tactical display for the U.S. Army's Bradley Fighting Vehicle, individually modeled their knowledge of 4 specific tasks employing the CAT-HCI tool. Measures of the accuracy and consistency of task models created by these task domain experts using the tool were compared with task models created by a double expert. The findings indicated a high degree of consistency and accuracy between the different "single experts" in the task domain in terms of the resultant models generated using the tool. Actual or potential applications of this research include assessing human-computer interaction complexity, determining the productivity of human-computer interfaces, and analyzing an interface design to determine whether methods can be automated.

  16. A prototype of a computerized patient record.

    PubMed

    Adelhard, K; Eckel, R; Hölzel, D; Tretter, W

    1995-01-01

    Computerized medical record systems (CPRS) should present user and problem oriented views of the patient file. Problem lists, clinical course, medication profiles and results of examinations have to be recorded in a computerized patient record. Patient review screens should give a synopsis of the patient data to inform whenever the patient record is opened. Several different types of data have to be stored in a patient record. Qualitative and quantitative measurements, narratives and images are such examples. Therefore, a CPR must also be able to handle these different data types. New methods and concepts appear frequently in medicine. Thus a CPRS must be flexible enough to cope with coming demands. We developed a prototype of a computer based patient record with a graphical user interface on a SUN workstation. The basis of the system are a dynamic data dictionary, an interpreter language and a large set of basic functions. This approach gives optimal flexibility to the system. A lot of different data types are already supported. Extensions are easily possible. There is also almost no limit concerning the number of medical concepts that can be handled by our prototype. Several applications were built on this platform. Some of them are presented to exemplify the patient and problem oriented handling of the CPR.

  17. VTGRAPH - GRAPHIC SOFTWARE TOOL FOR VT TERMINALS

    NASA Technical Reports Server (NTRS)

    Wang, C.

    1994-01-01

    VTGRAPH is a graphics software tool for DEC/VT or VT compatible terminals which are widely used by government and industry. It is a FORTRAN or C-language callable library designed to allow the user to deal with many computer environments which use VT terminals for window management and graphic systems. It also provides a PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. The program is transportable to many different computers which use VT terminals. With this graphics package, the user can easily design more friendly user interface programs and design PLOT10 programs on VT terminals with different computer systems. VTGRAPH was developed using the ReGis Graphics set which provides a full range of graphics capabilities. The basic VTGRAPH capabilities are as follows: window management, PLOT10 compatible drawing, generic program routines for two and three dimensional plotting, and color graphics or shaded graphics capability. The program was developed in VAX FORTRAN in 1988. VTGRAPH requires a ReGis graphics set terminal and a FORTRAN compiler. The program has been run on a DEC MicroVAX 3600 series computer operating under VMS 5.0, and has a virtual memory requirement of 5KB.

  18. A computerized procedure for teaching the relationship between graphic symbols and their referents.

    PubMed

    Isaacson, Mick; Lloyd, Lyle L

    2013-01-01

    Many individuals with little or no functional speech communicate through graphic symbols. Communication is enhanced when the relationship between symbols and their referents are learned to such a degree that retrieval is effortless, resulting in fluent communication. Developing fluency is a time consuming endeavor for special educators and speech-language pathologists (SLPs). It would be beneficial for these professionals to have an automated procedure based on the most efficacious method for teaching the relationship between symbols and referent. Hence, this study investigated whether a procedure based on the generation effect would promote learning the association between symbols and their referents. Results show that referent generation produces the best long-term retention of this relationship. These findings provide evidence that software based on referent generation would provide special educators and SLPs with an efficacious automated procedure, requiring minimal direct supervision, to facilitate symbol/referent learning and the development of communicative fluency.

  19. Impact of an electronic tool in prescribing primary prophylaxis with ciprofloxacin or granulocyte colony-stimulating factor for breast cancer patients receiving TC chemotherapy.

    PubMed

    Sulpher, Jeffrey; Giguere, Pierre; Hopkins, Sean; Dent, Susan

    2016-07-01

    The US Oncology Trial 9735 (doxorubicin and cyclophosphamide (AC) versus docetaxel and cyclophosphamide (TC)) reported febrile neutropenia (FN) in 5 % of patients receiving TC chemotherapy, in the absence of routine primary prophylaxis with granulocyte colony-stimulating factor (G-CSF) or antibiotics. In contrast, higher rates of FN have been reported in the 'real world' setting. This retrospective study compares the incidence and severity of FN and other TC-related toxicities before and after implementation of a primary prophylaxis computerized prescribing tool. Medical records of 207 patients receiving adjuvant TC between May 1, 2006, and November 1, 2011, were reviewed for toxicity. The incidence for each TC adverse event was measured by an incident rate ratio (IRR), and chi-square analysis was used to compare the differences in severity of TC toxicities before and after use of a primary prophylaxis computerized prescribing tool, and to compare G-CSF and ciprofloxacin groups. The implementation of a computerized prescribing tool significantly increased the proportion of patients prescribed primary prophylaxis (18.2 vs. 97.4 %; p < 0.001). Prior to the change in practice, the incidence of FN (incidence rate ratio 3.87; 95 % CI [1.3, 11.5]) and neutropenia (OR 4.8; 95 % CI [2.0, 11.7]) was significantly higher. Primary prophylaxis significantly reduced the rate of febrile neutropenia (20 vs. 5.3 %, p = 0.003). No significant differences were found in incidence and severity of other TC-related toxicities. Patients who did not receive G-CSF were at a greater risk for neutropenia (OR 5.1, 95 % CI [1.06, 24.3]). There were insufficient patients treated with antibiotics alone to compare to those treated with G-CSF. Implementation of a computerized prescribing tool significantly increased the use of primary prophylaxis by treating physicians in patients receiving TC chemotherapy, which was associated with reduced incidence of febrile neutropenia. Further research efforts should focus on the incorporation and routine use of evidence-based practices using tools such as alerts and prompts, in order to optimize patient care and improve outcomes.

  20. Graphical Interfaces for Simulation.

    ERIC Educational Resources Information Center

    Hollan, J. D.; And Others

    This document presents a discussion of the development of a set of software tools to assist in the construction of interfaces to simulations and real-time systems. Presuppositions to the approach to interface design that was used are surveyed, the tools are described, and the conclusions drawn from these experiences in graphical interface design…

  1. Chips: A Tool for Developing Software Interfaces Interactively.

    ERIC Educational Resources Information Center

    Cunningham, Robert E.; And Others

    This report provides a detailed description of Chips, an interactive tool for developing software employing graphical/computer interfaces on Xerox Lisp machines. It is noted that Chips, which is implemented as a collection of customizable classes, provides the programmer with a rich graphical interface for the creation of rich graphical…

  2. Building the Vocational Phase of the Computerized Motor Skills Testing System for Use in the Electronics and Electrical Engineering Group and Hospitality Group

    ERIC Educational Resources Information Center

    Hsiao, Hsien-Sheng; Chen, Jyun-Chen; Hong, Kunde

    2016-01-01

    Technical and vocational education emphasizes the development and training of hand motor skills. However, some problems exist in the current career and aptitude tests in that they do not truly measure the hand motor skills. This study used the Nintendo Wii Remote Controller as the testing device in developing a set of computerized testing tools to…

  3. Design and validation of an improved graphical user interface with the 'Tool ball'.

    PubMed

    Lee, Kuo-Wei; Lee, Ying-Chu

    2012-01-01

    The purpose of this research is introduce the design of an improved graphical user interface (GUI) and verifies the operational efficiency of the proposed interface. Until now, clicking the toolbar with the mouse is the usual way to operate software functions. In our research, we designed an improved graphical user interface - a tool ball that is operated by a mouse wheel to perform software functions. Several experiments are conducted to measure the time needed to operate certain software functions with the traditional combination of "mouse click + tool button" and the proposed integration of "mouse wheel + tool ball". The results indicate that the tool ball design can accelerate the speed of operating software functions, decrease the number of icons on the screen, and enlarge the applications of the mouse wheel. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. LCFM - LIVING COLOR FRAME MAKER: PC GRAPHICS GENERATION AND MANAGEMENT TOOL FOR REAL-TIME APPLICATIONS

    NASA Technical Reports Server (NTRS)

    Truong, L. V.

    1994-01-01

    Computer graphics are often applied for better understanding and interpretation of data under observation. These graphics become more complicated when animation is required during "run-time", as found in many typical modern artificial intelligence and expert systems. Living Color Frame Maker is a solution to many of these real-time graphics problems. Living Color Frame Maker (LCFM) is a graphics generation and management tool for IBM or IBM compatible personal computers. To eliminate graphics programming, the graphic designer can use LCFM to generate computer graphics frames. The graphical frames are then saved as text files, in a readable and disclosed format, which can be easily accessed and manipulated by user programs for a wide range of "real-time" visual information applications. For example, LCFM can be implemented in a frame-based expert system for visual aids in management of systems. For monitoring, diagnosis, and/or controlling purposes, circuit or systems diagrams can be brought to "life" by using designated video colors and intensities to symbolize the status of hardware components (via real-time feedback from sensors). Thus status of the system itself can be displayed. The Living Color Frame Maker is user friendly with graphical interfaces, and provides on-line help instructions. All options are executed using mouse commands and are displayed on a single menu for fast and easy operation. LCFM is written in C++ using the Borland C++ 2.0 compiler for IBM PC series computers and compatible computers running MS-DOS. The program requires a mouse and an EGA/VGA display. A minimum of 77K of RAM is also required for execution. The documentation is provided in electronic form on the distribution medium in WordPerfect format. A sample MS-DOS executable is provided on the distribution medium. The standard distribution medium for this program is one 5.25 inch 360K MS-DOS format diskette. The contents of the diskette are compressed using the PKWARE archiving tools. The utility to unarchive the files, PKUNZIP.EXE, is included. The Living Color Frame Maker tool was developed in 1992.

  5. Computerized analysis and duplication of mandibular motion.

    PubMed

    Knap, F J; Abler, J H; Richardson, B L

    1975-05-01

    A new digital system has been devised to analyze and duplicate jaw motion. The arrangement of the electronic system offers a range of versatility which includes graphic as well as numerical data analysis. The duplicator linkage is identical to the sensor linkage which, together with an accurate model transfer system, results in an encouraging level of accuracy in jaw-motion duplication. The data collected from normal subjects should offer some new knowledge in the normal motions of the mandible as well as establish a reference for comparison with abnormal masticatory function.

  6. Procedure for extraction of disparate data from maps into computerized data bases

    NASA Technical Reports Server (NTRS)

    Junkin, B. G.

    1979-01-01

    A procedure is presented for extracting disparate sources of data from geographic maps and for the conversion of these data into a suitable format for processing on a computer-oriented information system. Several graphic digitizing considerations are included and related to the NASA Earth Resources Laboratory's Digitizer System. Current operating procedures for the Digitizer System are given in a simplified and logical manner. The report serves as a guide to those organizations interested in converting map-based data by using a comparable map digitizing system.

  7. Improving Students' Understanding of the Importance of Economic Consequences in Standard Setting: A Computerized Spreadsheet Tool.

    ERIC Educational Resources Information Center

    Ivancevich, Daniel M.; And Others

    1996-01-01

    Points out that political and economic pressures have sometimes caused the Financial Accounting Standards Board to alter standards. Presents a spreadsheet tool that demonstrates the economic consequences of adopting accounting standards. (SK)

  8. Tools for computer graphics applications

    NASA Technical Reports Server (NTRS)

    Phillips, R. L.

    1976-01-01

    Extensive research in computer graphics has produced a collection of basic algorithms and procedures whose utility spans many disciplines. These tools are described in terms of their fundamental aspects, implementations, applications, and availability. Programs which are discussed include basic data plotting, curve smoothing, and depiction of three dimensional surfaces. As an aid to potential users of these tools, particular attention is given to discussing their availability and, where applicable, their cost.

  9. SimHap GUI: an intuitive graphical user interface for genetic association analysis.

    PubMed

    Carter, Kim W; McCaskie, Pamela A; Palmer, Lyle J

    2008-12-25

    Researchers wishing to conduct genetic association analysis involving single nucleotide polymorphisms (SNPs) or haplotypes are often confronted with the lack of user-friendly graphical analysis tools, requiring sophisticated statistical and informatics expertise to perform relatively straightforward tasks. Tools, such as the SimHap package for the R statistics language, provide the necessary statistical operations to conduct sophisticated genetic analysis, but lacks a graphical user interface that allows anyone but a professional statistician to effectively utilise the tool. We have developed SimHap GUI, a cross-platform integrated graphical analysis tool for conducting epidemiological, single SNP and haplotype-based association analysis. SimHap GUI features a novel workflow interface that guides the user through each logical step of the analysis process, making it accessible to both novice and advanced users. This tool provides a seamless interface to the SimHap R package, while providing enhanced functionality such as sophisticated data checking, automated data conversion, and real-time estimations of haplotype simulation progress. SimHap GUI provides a novel, easy-to-use, cross-platform solution for conducting a range of genetic and non-genetic association analyses. This provides a free alternative to commercial statistics packages that is specifically designed for genetic association analysis.

  10. Application of ERTS-1 data to the protection and management of New Jersey's coastal environment

    NASA Technical Reports Server (NTRS)

    Yunghans, R. S.; Feinberg, E. B.; Wobber, F. J.; Mairs, R. L. (Principal Investigator); Macomber, R. T.; Stanczuk, D.; Stitt, J. A.

    1974-01-01

    The author has identified the following significant results. Rapid access to ERTS data was provided by NASA GSFC for the February 26, 1974 overpass of the New Jersey test site. Forty-seven hours following the overpass computer-compatible tapes were ready for processing at EarthSat. The finished product was ready just 60 hours following the overpass and delivered to the New Jersey Department of Environmental Protection. This operational demonstration has been successful in convincing NJDEP as to the worth of ERTS as an operational monitoring and enforcement tool of significant value to the State. An erosion/ accretion severity index has been developed for the New Jersey shore case study area. Computerized analysis techniques have been used for monitoring offshore waste disposal dumping locations, drift vectors, and dispersion rates in the New York Bight area. A computer shade print of the area was used to identify intensity levels of acid waste. A Litton intensity slice print was made to provide graphic presentation of dispersion characteristics and the dump extent. Continued monitoring will lead to the recommendation and justification of permanent dumping sites which pose no threat to water quality in nearshore environments.

  11. Engineering computer graphics in gas turbine engine design, analysis and manufacture

    NASA Technical Reports Server (NTRS)

    Lopatka, R. S.

    1975-01-01

    A time-sharing and computer graphics facility designed to provide effective interactive tools to a large number of engineering users with varied requirements was described. The application of computer graphics displays at several levels of hardware complexity and capability is discussed, with examples of graphics systems tracing gas turbine product development, beginning with preliminary design through manufacture. Highlights of an operating system stylized for interactive engineering graphics is described.

  12. COMPLY

    EPA Pesticide Factsheets

    A computerized screening tool for evaluating radiation exposure from atmospheric releases of radionuclides. May be used for demonstrating compliance with some EPA and Nuclear Regulatory Commission regulations

  13. The MATH--Open Source Application for Easier Learning of Numerical Mathematics

    ERIC Educational Resources Information Center

    Glaser-Opitz, Henrich; Budajová, Kristina

    2016-01-01

    The article introduces a software application (MATH) supporting an education of Applied Mathematics, with focus on Numerical Mathematics. The MATH is an easy to use tool supporting various numerical methods calculations with graphical user interface and integrated plotting tool for graphical representation written in Qt with extensive use of Qwt…

  14. Solving Additive Problems at Pre-Elementary School Level with the Support of Graphical Representation

    ERIC Educational Resources Information Center

    Selva, Ana Coelho Vieira; Falcao, Jorge Tarcisio da Rocha; Nunes, Terezinha

    2005-01-01

    This research offers empirical evidence of the importance of supplying diverse symbolic representations in order to support concept development in mathematics. Graphical representation can be a helpful symbolic tool for concept development in the conceptual field of additive structures. Nevertheless, this symbolic tool has specific difficulties…

  15. Computerized Design Synthesis (CDS), A database-driven multidisciplinary design tool

    NASA Technical Reports Server (NTRS)

    Anderson, D. M.; Bolukbasi, A. O.

    1989-01-01

    The Computerized Design Synthesis (CDS) system under development at McDonnell Douglas Helicopter Company (MDHC) is targeted to make revolutionary improvements in both response time and resource efficiency in the conceptual and preliminary design of rotorcraft systems. It makes the accumulated design database and supporting technology analysis results readily available to designers and analysts of technology, systems, and production, and makes powerful design synthesis software available in a user friendly format.

  16. Computerizing Audit Studies

    PubMed Central

    Lahey, Joanna N.; Beasley, Ryan A.

    2014-01-01

    This paper briefly discusses the history, benefits, and shortcomings of traditional audit field experiments to study market discrimination. Specifically it identifies template bias and experimenter bias as major concerns in the traditional audit method, and demonstrates through an empirical example that computerization of a resume or correspondence audit can efficiently increase sample size and greatly mitigate these concerns. Finally, it presents a useful meta-tool that future researchers can use to create their own resume audits. PMID:24904189

  17. Performances on the CogState and standard neuropsychological batteries among HIV patients without dementia.

    PubMed

    Overton, Edgar Turner; Kauwe, John S K; Paul, Robert; Tashima, Karen; Tate, David F; Patel, Pragna; Carpenter, Charles C J; Patty, David; Brooks, John T; Clifford, David B

    2011-11-01

    HIV-associated neurocognitive disorders remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (P < 0.01). These data confirm previous correlation data with the computerized battery. Using the five significant parameters from the regression model in a Receiver Operating Characteristic curve, 90% of persons were accurately classified as being cognitively impaired or not. The test battery requires additional evaluation, specifically for identifying persons with mild impairment, a state upon which interventions may be effective.

  18. Computerized general practice based networks yield comparable performance with sentinel data in monitoring epidemiological time-course of influenza-like illness and acute respiratory illness.

    PubMed

    Truyers, Carla; Lesaffre, Emmanuel; Bartholomeeusen, Stefaan; Aertgeerts, Bert; Snacken, René; Brochier, Bernard; Yane, Fernande; Buntinx, Frank

    2010-03-22

    Computerized morbidity registration networks might serve as early warning systems in a time where natural epidemics such as the H1N1 flu can easily spread from one region to another. In this contribution we examine whether general practice based broad-spectrum computerized morbidity registration networks have the potential to act as a valid surveillance instrument of frequently occurring diseases. We compare general practice based computerized data assessing the frequency of influenza-like illness (ILI) and acute respiratory infections (ARI) with data from a well established case-specific sentinel network, the European Influenza Surveillance Scheme (EISS). The overall frequency and trends of weekly ILI and ARI data are compared using both networks. Detection of influenza-like illness and acute respiratory illness occurs equally fast in EISS and the computerized network. The overall frequency data for ARI are the same for both networks, the overall trends are similar, but the increases and decreases in frequency do not occur in exactly the same weeks. For ILI, the overall rate was slightly higher for the computerized network population, especially before the increase of ILI, the overall trend was almost identical and the increases and decreases occur in the same weeks for both networks. Computerized morbidity registration networks are a valid tool for monitoring frequent occurring respiratory diseases and the detection of sudden outbreaks.

  19. Automated Communication Tools and Computer-Based Medication Reconciliation to Decrease Hospital Discharge Medication Errors.

    PubMed

    Smith, Kenneth J; Handler, Steven M; Kapoor, Wishwa N; Martich, G Daniel; Reddy, Vivek K; Clark, Sunday

    2016-07-01

    This study sought to determine the effects of automated primary care physician (PCP) communication and patient safety tools, including computerized discharge medication reconciliation, on discharge medication errors and posthospitalization patient outcomes, using a pre-post quasi-experimental study design, in hospitalized medical patients with ≥2 comorbidities and ≥5 chronic medications, at a single center. The primary outcome was discharge medication errors, compared before and after rollout of these tools. Secondary outcomes were 30-day rehospitalization, emergency department visit, and PCP follow-up visit rates. This study found that discharge medication errors were lower post intervention (odds ratio = 0.57; 95% confidence interval = 0.44-0.74; P < .001). Clinically important errors, with the potential for serious or life-threatening harm, and 30-day patient outcomes were not significantly different between study periods. Thus, automated health system-based communication and patient safety tools, including computerized discharge medication reconciliation, decreased hospital discharge medication errors in medically complex patients. © The Author(s) 2015.

  20. Graphical Representations of Electronic Search Patterns.

    ERIC Educational Resources Information Center

    Lin, Xia; And Others

    1991-01-01

    Discussion of search behavior in electronic environments focuses on the development of GRIP (Graphic Representor of Interaction Patterns), a graphing tool based on HyperCard that produces graphic representations of search patterns. Search state spaces are explained, and forms of data available from electronic searches are described. (34…

  1. Geometrically Evident: Framing Studies Using the Graphic Appraisal Tool for Epidemiology (GATE)

    ERIC Educational Resources Information Center

    Martin, Andres; Srihari, Vinod

    2006-01-01

    Educators in evidence-based medicine (EBM) have noted that the core set of epidemiological concepts outlined in standard sources are sometimes put to use as oversimplified checklists for the appraisal of research reports. In this article, the authors present the Graphic Appraisal Tool for Epidemiology which was designed as a way combat, by visual…

  2. Graphical Requirements for Force Level Planning. Volume 2

    DTIC Science & Technology

    1991-09-01

    technology review includes graphics algorithms, computer hardware, computer software, and design methodologies. The technology can either exist today or...level graphics language. 7.4 User Interface Design Tools As user interfaces have become more sophisticated, they have become harder to develop. Xl...Setphen M. Pizer, editors. Proceedings 1986 Workshop on Interactive 31) Graphics , October 1986. 18 J. S. Dumas. Designing User Interface Software. Prentice

  3. SimHap GUI: An intuitive graphical user interface for genetic association analysis

    PubMed Central

    Carter, Kim W; McCaskie, Pamela A; Palmer, Lyle J

    2008-01-01

    Background Researchers wishing to conduct genetic association analysis involving single nucleotide polymorphisms (SNPs) or haplotypes are often confronted with the lack of user-friendly graphical analysis tools, requiring sophisticated statistical and informatics expertise to perform relatively straightforward tasks. Tools, such as the SimHap package for the R statistics language, provide the necessary statistical operations to conduct sophisticated genetic analysis, but lacks a graphical user interface that allows anyone but a professional statistician to effectively utilise the tool. Results We have developed SimHap GUI, a cross-platform integrated graphical analysis tool for conducting epidemiological, single SNP and haplotype-based association analysis. SimHap GUI features a novel workflow interface that guides the user through each logical step of the analysis process, making it accessible to both novice and advanced users. This tool provides a seamless interface to the SimHap R package, while providing enhanced functionality such as sophisticated data checking, automated data conversion, and real-time estimations of haplotype simulation progress. Conclusion SimHap GUI provides a novel, easy-to-use, cross-platform solution for conducting a range of genetic and non-genetic association analyses. This provides a free alternative to commercial statistics packages that is specifically designed for genetic association analysis. PMID:19109877

  4. Graphics; For Regional Policy Making, a Preliminary Study.

    ERIC Educational Resources Information Center

    Ewald, William R., Jr.

    The use of graphics (maps, charts, diagrams, renderings, photographs) for regional policy formulation and decision making is discussed at length. The report identifies the capabilities of a number of tools for analysis/synthesis/communication, especially computer assisted graphics to assist in community self-education and the management of change.…

  5. Mage: A Tool for Developing Interactive Instructional Graphics

    ERIC Educational Resources Information Center

    Pavkovic, Stephen F.

    2005-01-01

    Mage is a graphics program developed for visualization of three-dimensional structures of proteins and other macromolecules. An application of the Mage program is reported here for developing interactive instructional graphics files (kinemages) of much smaller scale. Examples are given illustrating features of VSEPR models, permanent dipoles,…

  6. Enhancing Comprehension through Graphic Organizers.

    ERIC Educational Resources Information Center

    Ben-David, Renee

    The purpose of this study was to determine whether graphic organizers serve as a better tool for comprehension assessment than traditional tests. Subjects, 16 seventh-grade learning disabled students, were given 8 weeks of instruction and assessments using both graphic organizer and linear note forms. Tests were graded, compared and contrasted to…

  7. Conceptual Learning with Multiple Graphical Representations: Intelligent Tutoring Systems Support for Sense-Making and Fluency-Building Processes

    ERIC Educational Resources Information Center

    Rau, Martina A.

    2013-01-01

    Most learning environments in the STEM disciplines use multiple graphical representations along with textual descriptions and symbolic representations. Multiple graphical representations are powerful learning tools because they can emphasize complementary aspects of complex learning contents. However, to benefit from multiple graphical…

  8. SEURAT: visual analytics for the integrated analysis of microarray data.

    PubMed

    Gribov, Alexander; Sill, Martin; Lück, Sonja; Rücker, Frank; Döhner, Konstanze; Bullinger, Lars; Benner, Axel; Unwin, Antony

    2010-06-03

    In translational cancer research, gene expression data is collected together with clinical data and genomic data arising from other chip based high throughput technologies. Software tools for the joint analysis of such high dimensional data sets together with clinical data are required. We have developed an open source software tool which provides interactive visualization capability for the integrated analysis of high-dimensional gene expression data together with associated clinical data, array CGH data and SNP array data. The different data types are organized by a comprehensive data manager. Interactive tools are provided for all graphics: heatmaps, dendrograms, barcharts, histograms, eventcharts and a chromosome browser, which displays genetic variations along the genome. All graphics are dynamic and fully linked so that any object selected in a graphic will be highlighted in all other graphics. For exploratory data analysis the software provides unsupervised data analytics like clustering, seriation algorithms and biclustering algorithms. The SEURAT software meets the growing needs of researchers to perform joint analysis of gene expression, genomical and clinical data.

  9. SpineCreator: a Graphical User Interface for the Creation of Layered Neural Models.

    PubMed

    Cope, A J; Richmond, P; James, S S; Gurney, K; Allerton, D J

    2017-01-01

    There is a growing requirement in computational neuroscience for tools that permit collaborative model building, model sharing, combining existing models into a larger system (multi-scale model integration), and are able to simulate models using a variety of simulation engines and hardware platforms. Layered XML model specification formats solve many of these problems, however they are difficult to write and visualise without tools. Here we describe a new graphical software tool, SpineCreator, which facilitates the creation and visualisation of layered models of point spiking neurons or rate coded neurons without requiring the need for programming. We demonstrate the tool through the reproduction and visualisation of published models and show simulation results using code generation interfaced directly into SpineCreator. As a unique application for the graphical creation of neural networks, SpineCreator represents an important step forward for neuronal modelling.

  10. EasyModeller: A graphical interface to MODELLER

    PubMed Central

    2010-01-01

    Background MODELLER is a program for automated protein Homology Modeling. It is one of the most widely used tool for homology or comparative modeling of protein three-dimensional structures, but most users find it a bit difficult to start with MODELLER as it is command line based and requires knowledge of basic Python scripting to use it efficiently. Findings The study was designed with an aim to develop of "EasyModeller" tool as a frontend graphical interface to MODELLER using Perl/Tk, which can be used as a standalone tool in windows platform with MODELLER and Python preinstalled. It helps inexperienced users to perform modeling, assessment, visualization, and optimization of protein models in a simple and straightforward way. Conclusion EasyModeller provides a graphical straight forward interface and functions as a stand-alone tool which can be used in a standard personal computer with Microsoft Windows as the operating system. PMID:20712861

  11. Macro controlling of copper oxide deposition processes and spray mode by using home-made fully computerized spray pyrolysis system

    NASA Astrophysics Data System (ADS)

    Essa, Mohammed Sh.; Chiad, Bahaa T.; Shafeeq, Omer Sh.

    2017-09-01

    Thin Films of Copper Oxide (CuO) absorption layer have been deposited using home-made Fully Computerized Spray Pyrolysis Deposition system FCSPD on glass substrates, at the nozzle to substrate distance equal to 20,35 cm, and computerized spray mode (continues spray, macro-control spray). The substrate temperature has been kept at 450 °c with the optional user can enter temperature tolerance values ± 5 °C. Also that fixed molar concentration of 0.1 M, and 2D platform speed or deposition platform speed of 4mm/s. more than 1000 instruction program code, and specific design of graphical user interface GUI to fully control the deposition process and real-time monitoring and controlling the deposition temperature at every 200 ms. The changing in the temperature has been recorded during deposition processes, in addition to all deposition parameters. The films have been characterized to evaluate the thermal distribution over the X, Y movable hot plate, the structure and optical energy gap, thermal and temperature distribution exhibited a good and uniform distribution over 20 cm2 hot plate area, X-ray diffraction (XRD) measurement revealed that the films are polycrystalline in nature and can be assigned to monoclinic CuO structure. Optical band gap varies from 1.5-1.66 eV depending on deposition parameter.

  12. Transportable Applications Environment (TAE) Plus: A NASA tool for building and managing graphical user interfaces

    NASA Technical Reports Server (NTRS)

    Szczur, Martha R.

    1991-01-01

    The Transportable Applications Environment (TAE) Plus, developed at GSFC, is an advanced portable user interface development environment which simplifies the process of creating and managing complex application graphical user interfaces (GUI's), supports prototyping, allows applications to be ported easily between different platforms and encourages appropriate levels of user interface consistency between applications. The following topics are discussed: the capabilities of the TAE Plus tool; how the implementation has utilized state-of-the-art technologies within graphic workstations; and how it has been used both within and outside of NASA.

  13. Einstein's Riddle as a Tool for Profiling Students

    ERIC Educational Resources Information Center

    Özeke, Vildan; Akçapina, Gökhan

    2016-01-01

    There are many computer games, learning environments, online tutoring systems or computerized tools which keeps the track of the user while learning or engaging in the activities. This paper presents results from an exploratory study and aims to group students regarding their behavior data while solving the Einstein's riddle. 45 undergraduate…

  14. Command History for 1990

    DTIC Science & Technology

    1991-05-01

    Marine Corps Tiaining Systems (CBESS) memorization training Inteligence Center, Dam Neck Threat memorization training Commander Tactical Wings, Atlantic...News Shipbuilding Technical training AEGIS Training Center, Dare Artificial Intelligence (Al) Tools Computerized firm-end analysis tools NETSCPAC...Technology Department and provides computational and electronic mail support for research in areas of artificial intelligence, computer-assisted instruction

  15. Public Domain Generic Tools: An Overview.

    ERIC Educational Resources Information Center

    Erjavec, Tomaz

    This paper presents an introduction to language engineering software, especially for computerized language and text corpora. The focus of the paper is on small and relatively independent pieces of software designed for specific, often low-level language analysis tasks, and on tools in the public domain. Discussion begins with the application of…

  16. Converting information from paper to optical media

    NASA Technical Reports Server (NTRS)

    Deaton, Timothy N.; Tiller, Bruce K.

    1990-01-01

    The technology of converting large amounts of paper into electronic form is described for use in information management systems based on optical disk storage. The space savings and photographic nature of microfiche are combined in these systems with the advantages of computerized data (fast and flexible retrieval of graphics and text, simultaneous instant access for multiple users, and easy manipulation of data). It is noted that electronic imaging systems offer a unique opportunity to dramatically increase the productivity and profitability of information systems. Particular attention is given to the CALS (Computer-aided Aquisition and Logistic Support) system.

  17. Use of Cloud-Based Graphic Narrative Software in Medical Ethics Teaching

    ERIC Educational Resources Information Center

    Weber, Alan S.

    2015-01-01

    Although used as a common pedagogical tool in K-12 education, online graphic narrative ("comics") software has not generally been incorporated into advanced professional or technical education. This contribution reports preliminary data from a study on the use of cloud-based graphics software Pixton.com to teach basic medical ethics…

  18. COINGRAD; Control Oriented Interactive Graphical Analysis and Design.

    ERIC Educational Resources Information Center

    Volz, Richard A.; And Others

    The computer is currently a vital tool in engineering analysis and design. With the introduction of moderately priced graphics terminals, it will become even more important in the future as rapid graphic interaction between the engineer and the computer becomes more feasible in computer-aided design (CAD). To provide a vehicle for introducing…

  19. The Effectiveness of Graphic Organizers to Support Executive Function for Ninth Grade Struggling Readers

    ERIC Educational Resources Information Center

    Barry, Elaine

    2016-01-01

    Struggling readers, or students who read below grade level but have strong phonological awareness, may benefit from using instructional tools like graphic organizers (GOs) while reading. The purpose of this study was to investigate the relationship between reading comprehension and teacher-generated graphic organizers (GOs) as they support…

  20. GUIdock-VNC: using a graphical desktop sharing system to provide a browser-based interface for containerized software

    PubMed Central

    Mittal, Varun; Hung, Ling-Hong; Keswani, Jayant; Kristiyanto, Daniel; Lee, Sung Bong

    2017-01-01

    Abstract Background: Software container technology such as Docker can be used to package and distribute bioinformatics workflows consisting of multiple software implementations and dependencies. However, Docker is a command line–based tool, and many bioinformatics pipelines consist of components that require a graphical user interface. Results: We present a container tool called GUIdock-VNC that uses a graphical desktop sharing system to provide a browser-based interface for containerized software. GUIdock-VNC uses the Virtual Network Computing protocol to render the graphics within most commonly used browsers. We also present a minimal image builder that can add our proposed graphical desktop sharing system to any Docker packages, with the end result that any Docker packages can be run using a graphical desktop within a browser. In addition, GUIdock-VNC uses the Oauth2 authentication protocols when deployed on the cloud. Conclusions: As a proof-of-concept, we demonstrated the utility of GUIdock-noVNC in gene network inference. We benchmarked our container implementation on various operating systems and showed that our solution creates minimal overhead. PMID:28327936

  1. GUIdock-VNC: using a graphical desktop sharing system to provide a browser-based interface for containerized software.

    PubMed

    Mittal, Varun; Hung, Ling-Hong; Keswani, Jayant; Kristiyanto, Daniel; Lee, Sung Bong; Yeung, Ka Yee

    2017-04-01

    Software container technology such as Docker can be used to package and distribute bioinformatics workflows consisting of multiple software implementations and dependencies. However, Docker is a command line-based tool, and many bioinformatics pipelines consist of components that require a graphical user interface. We present a container tool called GUIdock-VNC that uses a graphical desktop sharing system to provide a browser-based interface for containerized software. GUIdock-VNC uses the Virtual Network Computing protocol to render the graphics within most commonly used browsers. We also present a minimal image builder that can add our proposed graphical desktop sharing system to any Docker packages, with the end result that any Docker packages can be run using a graphical desktop within a browser. In addition, GUIdock-VNC uses the Oauth2 authentication protocols when deployed on the cloud. As a proof-of-concept, we demonstrated the utility of GUIdock-noVNC in gene network inference. We benchmarked our container implementation on various operating systems and showed that our solution creates minimal overhead. © The Authors 2017. Published by Oxford University Press.

  2. Evaluation of computerized health management information system for primary health care in rural India

    PubMed Central

    2010-01-01

    Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS), New Delhi has a computerized Health Management Information System (HMIS) since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors) and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR) 1674,217 (USD 35,622). Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213). The annual savings is around INR 894,283 (USD 11,924). Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision. PMID:21078203

  3. IMAT graphics manual

    NASA Technical Reports Server (NTRS)

    Stockwell, Alan E.; Cooper, Paul A.

    1991-01-01

    The Integrated Multidisciplinary Analysis Tool (IMAT) consists of a menu driven executive system coupled with a relational database which links commercial structures, structural dynamics and control codes. The IMAT graphics system, a key element of the software, provides a common interface for storing, retrieving, and displaying graphical information. The IMAT Graphics Manual shows users of commercial analysis codes (MATRIXx, MSC/NASTRAN and I-DEAS) how to use the IMAT graphics system to obtain high quality graphical output using familiar plotting procedures. The manual explains the key features of the IMAT graphics system, illustrates their use with simple step-by-step examples, and provides a reference for users who wish to take advantage of the flexibility of the software to customize their own applications.

  4. Graphical User Interface Development and Design to Support Airport Runway Configuration Management

    NASA Technical Reports Server (NTRS)

    Jones, Debra G.; Lenox, Michelle; Onal, Emrah; Latorella, Kara A.; Lohr, Gary W.; Le Vie, Lisa

    2015-01-01

    The objective of this effort was to develop a graphical user interface (GUI) for the National Aeronautics and Space Administration's (NASA) System Oriented Runway Management (SORM) decision support tool to support runway management. This tool is expected to be used by traffic flow managers and supervisors in the Airport Traffic Control Tower (ATCT) and Terminal Radar Approach Control (TRACON) facilities.

  5. The Effects of the Use of Microsoft Math Tool (Graphical Calculator) Instruction on Students' Performance in Linear Functions

    ERIC Educational Resources Information Center

    Kissi, Philip Siaw; Opoku, Gyabaah; Boateng, Sampson Kwadwo

    2016-01-01

    The aim of the study was to investigate the effect of Microsoft Math Tool (graphical calculator) on students' achievement in the linear function. The study employed Quasi-experimental research design (Pre-test Post-test two group designs). A total of ninety-eight (98) students were selected for the study from two different Senior High Schools…

  6. 2D-dynamic representation of DNA sequences as a graphical tool in bioinformatics

    NASA Astrophysics Data System (ADS)

    Bielińska-Wa̧Ż, D.; Wa̧Ż, P.

    2016-10-01

    2D-dynamic representation of DNA sequences is briefly reviewed. Some new examples of 2D-dynamic graphs which are the graphical tool of the method are shown. Using the examples of the complete genome sequences of the Zika virus it is shown that the present method can be applied for the study of the evolution of viral genomes.

  7. A Graphic Symbol Tool for the Evaluation of Communication, Satisfaction and Priorities of Individuals with Intellectual Disability Who Use a Speech Generating Device

    ERIC Educational Resources Information Center

    Valiquette, Christine; Sutton, Ann; Ska, Bernadette

    2010-01-01

    This article reports on the views of individuals with learning disability (LD) on their use of their speech generating devices (SGDs), their satisfaction about their communication, and their priorities. The development of an interview tool made of graphic symbols and entitled Communication, Satisfaction and Priorities of SGD Users (CSPU) is…

  8. The process of development of a prioritization tool for a clinical decision support build within a computerized provider order entry system: Experiences from St Luke's Health System.

    PubMed

    Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent

    2016-09-01

    To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.

  9. Data engineering systems: Computerized modeling and data bank capabilities for engineering analysis

    NASA Technical Reports Server (NTRS)

    Kopp, H.; Trettau, R.; Zolotar, B.

    1984-01-01

    The Data Engineering System (DES) is a computer-based system that organizes technical data and provides automated mechanisms for storage, retrieval, and engineering analysis. The DES combines the benefits of a structured data base system with automated links to large-scale analysis codes. While the DES provides the user with many of the capabilities of a computer-aided design (CAD) system, the systems are actually quite different in several respects. A typical CAD system emphasizes interactive graphics capabilities and organizes data in a manner that optimizes these graphics. On the other hand, the DES is a computer-aided engineering system intended for the engineer who must operationally understand an existing or planned design or who desires to carry out additional technical analysis based on a particular design. The DES emphasizes data retrieval in a form that not only provides the engineer access to search and display the data but also links the data automatically with the computer analysis codes.

  10. Computerized Cognitive Rehabilitation of Attention and Executive Function in Acquired Brain Injury: A Systematic Review.

    PubMed

    Bogdanova, Yelena; Yee, Megan K; Ho, Vivian T; Cicerone, Keith D

    Comprehensive review of the use of computerized treatment as a rehabilitation tool for attention and executive function in adults (aged 18 years or older) who suffered an acquired brain injury. Systematic review of empirical research. Two reviewers independently assessed articles using the methodological quality criteria of Cicerone et al. Data extracted included sample size, diagnosis, intervention information, treatment schedule, assessment methods, and outcome measures. A literature review (PubMed, EMBASE, Ovid, Cochrane, PsychINFO, CINAHL) generated a total of 4931 publications. Twenty-eight studies using computerized cognitive interventions targeting attention and executive functions were included in this review. In 23 studies, significant improvements in attention and executive function subsequent to training were reported; in the remaining 5, promising trends were observed. Preliminary evidence suggests improvements in cognitive function following computerized rehabilitation for acquired brain injury populations including traumatic brain injury and stroke. Further studies are needed to address methodological issues (eg, small sample size, inadequate control groups) and to inform development of guidelines and standardized protocols.

  11. Computerized N-acetylcysteine physician order entry by template protocol for acetaminophen toxicity.

    PubMed

    Thompson, Trevonne M; Lu, Jenny J; Blackwood, Louisa; Leikin, Jerrold B

    2011-01-01

    Some medication dosing protocols are logistically complex for traditional physician ordering. The use of computerized physician order entry (CPOE) with templates, or order sets, may be useful to reduce medication administration errors. This study evaluated the rate of medication administration errors using CPOE order sets for N-acetylcysteine (NAC) use in treating acetaminophen poisoning. An 18-month retrospective review of computerized inpatient pharmacy records for NAC use was performed. All patients who received NAC for the treatment of acetaminophen poisoning were included. Each record was analyzed to determine the form of NAC given and whether an administration error occurred. In the 82 cases of acetaminophen poisoning in which NAC was given, no medication administration errors were identified. Oral NAC was given in 31 (38%) cases; intravenous NAC was given in 51 (62%) cases. In this retrospective analysis of N-acetylcysteine administration using computerized physician order entry and order sets, no medication administration errors occurred. CPOE is an effective tool in safely executing complicated protocols in an inpatient setting.

  12. ALASKAN RTMA GRAPHICS

    Science.gov Websites

    Alaskan RTMA Graphics This page displays Alaskan Real-Time Mesoscale Analyses and compares them to DISCLAIMER: The Alaskan Real-Time Mesoscale Analysis tool is in its developmental stage, and there is much

  13. Color postprocessing for 3-dimensional finite element mesh quality evaluation and evolving graphical workstation

    NASA Technical Reports Server (NTRS)

    Panthaki, Malcolm J.

    1987-01-01

    Three general tasks on general-purpose, interactive color graphics postprocessing for three-dimensional computational mechanics were accomplished. First, the existing program (POSTPRO3D) is ported to a high-resolution device. In the course of this transfer, numerous enhancements are implemented in the program. The performance of the hardware was evaluated from the point of view of engineering postprocessing, and the characteristics of future hardware were discussed. Second, interactive graphical tools implemented to facilitate qualitative mesh evaluation from a single analysis. The literature was surveyed and a bibliography compiled. Qualitative mesh sensors were examined, and the use of two-dimensional plots of unaveraged responses on the surface of three-dimensional continua was emphasized in an interactive color raster graphics environment. Finally, a postprocessing environment was designed for state-of-the-art workstation technology. Modularity, personalization of the environment, integration of the engineering design processes, and the development and use of high-level graphics tools are some of the features of the intended environment.

  14. Slide shows vs graphic tablet live drawing for anatomy teaching.

    PubMed

    Alsaid, B

    2016-12-01

    Blackboard drawing is the traditional and still widely learned method for anatomy teachers. However, for practical reasons, more and more lessons are done using slide shows. New digital learning tools are developed to create a more attractive teaching method. The objective of this study was to compare the use of graphic tablet live drawing versus slide shows. Sixty-five second-year students of the Faculty of Medicine participated in this study during their first semester of 2013-2014 academic year. The selected lecture dealt about neuroanatomy; two brain sections were taught: median sagittal and transverse. The sagittal section was presented via a slide show. The transverse section was taught using a graphics tablet using drawing software. Students were evaluated three times: before the lecture, immediately after the lecture and 8 weeks later. Means were compared using a t-test. Scores were significantly higher immediately after the lecture and 8 weeks later tests in comparing the transverse section (using the graphics tablet) versus the sagittal section (using PowerPoint ® ). Student satisfaction regarding the use of the tablet was high. The graphics tablet is a usable and efficient drawing tool in anatomy teaching. This tool requires a specific teacher training and preparation. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Implementation of a Computerized Order Entry Tool to Reduce the Inappropriate and Unnecessary Use of Cardiac Stress Tests With Imaging in Hospitalized Patients.

    PubMed

    Gertz, Zachary M; O'Donnell, William; Raina, Amresh; Balderston, Jessica R; Litwack, Andrew J; Goldberg, Lee R

    2016-10-15

    The rising use of imaging cardiac stress tests has led to potentially unnecessary testing. Interventions designed to reduce inappropriate stress testing have focused on the ambulatory setting. We developed a computerized order entry tool intended to reduce the use of imaging cardiac stress tests and improve appropriate use in hospitalized patients. The tool was evaluated using preimplementation and postimplementation cohorts at a single urban academic teaching hospital. All hospitalized patients referred for testing were included. The co-primary outcomes were the use of imaging stress tests as a percentage of all stress tests and the percentage of inappropriate tests, compared between the 2 cohorts. There were 478 patients in the precohort and 463 in the postcohort. The indication was chest pain in 66% and preoperative in 18% and was not significantly different between groups. The use of nonimaging stress tests increased from 4% in the pregroup to 15% in the postgroup (p <0.001). Among very low-risk chest pain patients, the use of nonimaging stress tests increased from 7% to 25% (p <0.001). Inappropriate testing did not change significantly between groups (12% vs 11%). Inappropriate tests were most often preoperative evaluations (83%). In conclusion, our computerized ordering tool significantly increased the use of nonimaging cardiac stress tests and reduced the use of imaging tests yet was not able to reduce inappropriate use. Our study highlights the differences in cardiac stress testing between hospitalized and ambulatory patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. [Is there life beyond SPSS? Discover R].

    PubMed

    Elosua Oliden, Paula

    2009-11-01

    R is a GNU statistical and programming environment with very high graphical capabilities. It is very powerful for research purposes, but it is also an exceptional tool for teaching. R is composed of more than 1400 packages that allow using it for simple statistics and applying the most complex and most recent formal models. Using graphical interfaces like the Rcommander package, permits working in user-friendly environments which are similar to the graphical environment used by SPSS. This last characteristic allows non-statisticians to overcome the obstacle of accessibility, and it makes R the best tool for teaching. Is there anything better? Open, free, affordable, accessible and always on the cutting edge.

  17. Assessing Probabilistic Reasoning in Verbal-Numerical and Graphical-Pictorial Formats: An Evaluation of the Psychometric Properties of an Instrument

    ERIC Educational Resources Information Center

    Agus, Mirian; Penna, Maria Pietronilla; Peró-Cebollero, Maribel; Guàrdia-Olmos, Joan

    2016-01-01

    Research on the graphical facilitation of probabilistic reasoning has been characterised by the effort expended to identify valid assessment tools. The authors developed an assessment instrument to compare reasoning performances when problems were presented in verbal-numerical and graphical-pictorial formats. A sample of undergraduate psychology…

  18. Pre-Service Science Teachers' Construction and Interpretation of Graphs

    ERIC Educational Resources Information Center

    Ergül, N. Remziye

    2018-01-01

    Data and graphic analysis and interpretation are important parts of science process skills and science curriculum. So it refers to visual display of data using relevant graphical representations. One of the tools used in science courses is graphics for explain the relationship among each of the concepts and therefore it is important to know data…

  19. Computerized Modeling and Loaded Tooth Contact Analysis of Hypoid Gears Manufactured by Face Hobbing Process

    NASA Astrophysics Data System (ADS)

    Nishino, Takayuki

    The face hobbing process has been widely applied in automotive industry. But so far few analytical tools have been developed. This makes it difficult for us to optimize gear design. To settle this situation, this study aims at developing a computerized tool to predict the running performances such as loaded tooth contact pattern, static transmission error and so on. First, based upon kinematical analysis of a cutting machine, a mathematical description of tooth surface generation is given. Second, based upon the theory of gearing and differential geometry, conjugate tooth surfaces are studied. Then contact lines are generated. Third, load distribution along contact lines is formulated. Last, the numerical model is validated by measuring loaded transmission error and loaded tooth contact pattern.

  20. 2-D Animation's Not Just for Mickey Mouse.

    ERIC Educational Resources Information Center

    Weinman, Lynda

    1995-01-01

    Discusses characteristics of two-dimensional (2-D) animation; highlights include character animation, painting issues, and motion graphics. Sidebars present Silicon Graphics animations tools and 2-D animation programs for the desktop computer. (DGM)

  1. HiRel - Reliability/availability integrated workstation tool

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Dugan, Joanne B.

    1992-01-01

    The HiRel software tool is described and demonstrated by application to the mission avionics subsystem of the Advanced System Integration Demonstrations (ASID) system that utilizes the PAVE PILLAR approach. HiRel marks another accomplishment toward the goal of producing a totally integrated computer-aided design (CAD) workstation design capability. Since a reliability engineer generally represents a reliability model graphically before it can be solved, the use of a graphical input description language increases productivity and decreases the incidence of error. The graphical postprocessor module HARPO makes it possible for reliability engineers to quickly analyze huge amounts of reliability/availability data to observe trends due to exploratory design changes. The addition of several powerful HARP modeling engines provides the user with a reliability/availability modeling capability for a wide range of system applications all integrated under a common interactive graphical input-output capability.

  2. An Open-Access Educational Tool for Teaching Motion Dynamics in Multi-Axis Servomotor Control

    ERIC Educational Resources Information Center

    Rivera-Guillen, J. R.; de Jesus Rangel-Magdaleno, J.; de Jesus Romero-Troncoso, R.; Osornio-Rios, R. A.; Guevara-Gonzalez, R. G.

    2012-01-01

    Servomotors are widely used in computerized numerically controlled (CNC) machines, hence motion control is a major topic covered in undergraduate/graduate engineering courses. Despite the fact that several syllabi include the motion dynamics topic in their courses, there are neither suitable tools available for designing and simulating multi-axis…

  3. The Language Exposure Assessment Tool: Quantifying Language Exposure in Infants and Children

    ERIC Educational Resources Information Center

    DeAnda, Stephanie; Bosch, Laura; Poulin-Dubois, Diane; Zesiger, Pascal; Friend, Margaret

    2016-01-01

    Purpose: The aim of this study was to develop the Language Exposure Assessment Tool (LEAT) and to examine its cross-linguistic validity, reliability, and utility. The LEAT is a computerized interview-style assessment that requests parents to estimate language exposure. The LEAT yields an automatic calculation of relative language exposure and…

  4. SEURAT: Visual analytics for the integrated analysis of microarray data

    PubMed Central

    2010-01-01

    Background In translational cancer research, gene expression data is collected together with clinical data and genomic data arising from other chip based high throughput technologies. Software tools for the joint analysis of such high dimensional data sets together with clinical data are required. Results We have developed an open source software tool which provides interactive visualization capability for the integrated analysis of high-dimensional gene expression data together with associated clinical data, array CGH data and SNP array data. The different data types are organized by a comprehensive data manager. Interactive tools are provided for all graphics: heatmaps, dendrograms, barcharts, histograms, eventcharts and a chromosome browser, which displays genetic variations along the genome. All graphics are dynamic and fully linked so that any object selected in a graphic will be highlighted in all other graphics. For exploratory data analysis the software provides unsupervised data analytics like clustering, seriation algorithms and biclustering algorithms. Conclusions The SEURAT software meets the growing needs of researchers to perform joint analysis of gene expression, genomical and clinical data. PMID:20525257

  5. Developing a Graphical User Interface for the ALSS Crop Planning Tool

    NASA Technical Reports Server (NTRS)

    Koehlert, Erik

    1997-01-01

    The goal of my project was to create a graphical user interface for a prototype crop scheduler. The crop scheduler was developed by Dr. Jorge Leon and Laura Whitaker for the ALSS (Advanced Life Support System) program. The addition of a system-independent graphical user interface to the crop planning tool will make the application more accessible to a wider range of users and enhance its value as an analysis, design, and planning tool. My presentation will demonstrate the form and functionality of this interface. This graphical user interface allows users to edit system parameters stored in the file system. Data on the interaction of the crew, crops, and waste processing system with the available system resources is organized and labeled. Program output, which is stored in the file system, is also presented to the user in performance-time plots and organized charts. The menu system is designed to guide the user through analysis and decision making tasks, providing some help if necessary. The Java programming language was used to develop this interface in hopes of providing portability and remote operation.

  6. Transputer parallel processing at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Ellis, Graham K.

    1989-01-01

    The transputer parallel processing lab at NASA Lewis Research Center (LeRC) consists of 69 processors (transputers) that can be connected into various networks for use in general purpose concurrent processing applications. The main goal of the lab is to develop concurrent scientific and engineering application programs that will take advantage of the computational speed increases available on a parallel processor over the traditional sequential processor. Current research involves the development of basic programming tools. These tools will help standardize program interfaces to specific hardware by providing a set of common libraries for applications programmers. The thrust of the current effort is in developing a set of tools for graphics rendering/animation. The applications programmer currently has two options for on-screen plotting. One option can be used for static graphics displays and the other can be used for animated motion. The option for static display involves the use of 2-D graphics primitives that can be called from within an application program. These routines perform the standard 2-D geometric graphics operations in real-coordinate space as well as allowing multiple windows on a single screen.

  7. Modeling biochemical transformation processes and information processing with Narrator.

    PubMed

    Mandel, Johannes J; Fuss, Hendrik; Palfreyman, Niall M; Dubitzky, Werner

    2007-03-27

    Software tools that model and simulate the dynamics of biological processes and systems are becoming increasingly important. Some of these tools offer sophisticated graphical user interfaces (GUIs), which greatly enhance their acceptance by users. Such GUIs are based on symbolic or graphical notations used to describe, interact and communicate the developed models. Typically, these graphical notations are geared towards conventional biochemical pathway diagrams. They permit the user to represent the transport and transformation of chemical species and to define inhibitory and stimulatory dependencies. A critical weakness of existing tools is their lack of supporting an integrative representation of transport, transformation as well as biological information processing. Narrator is a software tool facilitating the development and simulation of biological systems as Co-dependence models. The Co-dependence Methodology complements the representation of species transport and transformation together with an explicit mechanism to express biological information processing. Thus, Co-dependence models explicitly capture, for instance, signal processing structures and the influence of exogenous factors or events affecting certain parts of a biological system or process. This combined set of features provides the system biologist with a powerful tool to describe and explore the dynamics of life phenomena. Narrator's GUI is based on an expressive graphical notation which forms an integral part of the Co-dependence Methodology. Behind the user-friendly GUI, Narrator hides a flexible feature which makes it relatively easy to map models defined via the graphical notation to mathematical formalisms and languages such as ordinary differential equations, the Systems Biology Markup Language or Gillespie's direct method. This powerful feature facilitates reuse, interoperability and conceptual model development. Narrator is a flexible and intuitive systems biology tool. It is specifically intended for users aiming to construct and simulate dynamic models of biology without recourse to extensive mathematical detail. Its design facilitates mappings to different formal languages and frameworks. The combined set of features makes Narrator unique among tools of its kind. Narrator is implemented as Java software program and available as open-source from http://www.narrator-tool.org.

  8. Instruments of scientific visual representation in atomic databases

    NASA Astrophysics Data System (ADS)

    Kazakov, V. V.; Kazakov, V. G.; Meshkov, O. I.

    2017-10-01

    Graphic tools of spectral data representation provided by operating information systems on atomic spectroscopy—ASD NIST, VAMDC, SPECTR-W3, and Electronic Structure of Atoms—for the support of scientific-research and human-resource development are presented. Such tools of visual representation of scientific data as those of the spectrogram and Grotrian diagram plotting are considered. The possibility of comparative analysis of the experimentally obtained spectra and reference spectra of atomic systems formed according to the database of a resource is described. The access techniques to the mentioned graphic tools are presented.

  9. The F-SCAN system of foot pressure analysis.

    PubMed

    Young, C R

    1993-07-01

    The age of computerized gait analysis is here. There are several systems available to meet the needs of the podiatric practitioner. This author believes that the F-SCAN technology system makes a significant contribution to the practice of podiatric medicine. The system is user friendly, accurate, reproducible, and affordable. Its graphic display capabilities are colorfully attractive and easily understood. The primary focus of the F-SCAN system is that of peak pressure distribution over time. Vertical plantar pressure dispersion across the plantar surface of the foot is recorded, processed, and graphically displayed in terms of sequential gait changes. The system further allows for the manipulation of the accumulated data to present it in a more comprehensive manner. Future updates on the F-SCAN software are already close at hand and are expected to enhance the diagnostic capabilities of the system further. The four primary areas of clinical application for F-SCAN have been identified and briefly discussed. The recognition of certain biomechanical abnormalities, monitoring preorthotic and postorthotic use, evaluation of the diabetic or neuropathic foot, and presurgical and postsurgical functional examinations constitute this group. The F-SCAN system largely helps to remove some of the unavoidable guess work from essential diagnostic and therapeutic procedures. As we increase our understanding of the pathomechanics of these clinical problems, so too will we improve our management of the associated complications. Years ago, at the time when computerized gait analysis was being introduced to the podiatric profession, a frequently asked question was: What does it tell me that I don't already know or can't see by watching the patient walk?(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Class Evolution Tree: A Graphical Tool to Support Decisions on the Number of Classes in Exploratory Categorical Latent Variable Modeling for Rehabilitation Research

    ERIC Educational Resources Information Center

    Kriston, Levente; Melchior, Hanne; Hergert, Anika; Bergelt, Corinna; Watzke, Birgit; Schulz, Holger; von Wolff, Alessa

    2011-01-01

    The aim of our study was to develop a graphical tool that can be used in addition to standard statistical criteria to support decisions on the number of classes in explorative categorical latent variable modeling for rehabilitation research. Data from two rehabilitation research projects were used. In the first study, a latent profile analysis was…

  11. Graphical Acoustic Liner Design and Analysis Tool

    NASA Technical Reports Server (NTRS)

    Howerton, Brian M. (Inventor); Jones, Michael G. (Inventor)

    2016-01-01

    An interactive liner design and impedance modeling tool comprises software utilized to design acoustic liners for use in constrained spaces, both regularly and irregularly shaped. A graphical user interface allows the acoustic channel geometry to be drawn in a liner volume while the surface impedance calculations are updated and displayed in real-time. A one-dimensional transmission line model may be used as the basis for the impedance calculations.

  12. Graphical Contingency Analysis for the Nation's Electric Grid

    ScienceCinema

    Zhenyu (Henry) Huang

    2017-12-09

    PNNL has developed a new tool to manage the electric grid more effectively, helping prevent blackouts and brownouts--and possibly avoiding millions of dollars in fines for system violations. The Graphical Contingency Analysis tool monitors grid performance, shows prioritized lists of problems, provides visualizations of potential consequences, and helps operators identify the most effective courses of action. This technology yields faster, better decisions and a more stable and reliable power grid.

  13. Views of general practitioners on the use of STOPP&START in primary care: a qualitative study.

    PubMed

    Dalleur, O; Feron, J-M; Spinewine, A

    2014-08-01

    STOPP (Screening Tool of Older Person's Prescriptions) and START (Screening Tool to Alert Doctors to Right Treatment) criteria aim at detecting potentially inappropriate prescribing in older people. The objective was to explore general practitioners' (GPs) perceptions regarding the use of the STOPP&START tool in their practice. We conducted three focus groups which were conveniently sampled. Vignettes with clinical cases were provided for discussion as well as a full version of the STOPP&START tool. Knowledge, strengths and weaknesses of the tool and its implementation were discussed. Two researchers independently performed content analysis, classifying quotes and creating new categories for emerging themes. Discussions highlighted incentives (e.g. systematic procedure for medication review) and barriers (e.g. time-consuming application) influencing the use of STOPP&START in primary care. Usefulness, comprehensiveness, and relevance of the tool were also questioned. Another important category emerging from the content analysis was the projected use of the tool. The GPs imagined key elements for the implementation in daily practice: computerized clinical decision support system, education, and multidisciplinary collaborations, especially at care transitions and in nursing homes. Despite variables views on the usefulness, comprehensiveness, and relevance of STOPP&START, GPs suggest the implementation of this tool in primary care within computerized clinical decision support systems, through education, and used as part of multidisciplinary collaborations.

  14. SMART INIT GRAPHICS

    Science.gov Websites

    NAM Smart Init Graphics This page displays 5km NAM forecast output made from the "smartinit DISCLAIMER: The Smart Init tool is in its developmental stage, and there is much work to be done. Feedback is

  15. Symbolic-Graphical Calculators: Teaching Tools for Mathematics.

    ERIC Educational Resources Information Center

    Dick, Thomas P.

    1992-01-01

    Explores the role that symbolic-graphical calculators can play in the current calls for reform in the mathematics curriculum. Discusses symbolic calculators and graphing calculators in relation to problem solving, computational skills, and mathematics instruction. (MDH)

  16. Nuclear medicine in clinical neurology: an update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldendorf, W.H.

    1981-01-01

    Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less

  17. Brain-wave measures of workload in advanced cockpits: The transition of technology from laboratory to cockpit simulator, phase 2

    NASA Technical Reports Server (NTRS)

    Horst, Richard L.; Mahaffey, David L.; Munson, Robert C.

    1989-01-01

    The present Phase 2 small business innovation research study was designed to address issues related to scalp-recorded event-related potential (ERP) indices of mental workload and to transition this technology from the laboratory to cockpit simulator environments for use as a systems engineering tool. The project involved five main tasks: (1) Two laboratory studies confirmed the generality of the ERP indices of workload obtained in the Phase 1 study and revealed two additional ERP components related to workload. (2) A task analysis' of flight scenarios and pilot tasks in the Advanced Concepts Flight Simulator (ACFS) defined cockpit events (i.e., displays, messages, alarms) that would be expected to elicit ERPs related to workload. (3) Software was developed to support ERP data analysis. An existing ARD-proprietary package of ERP data analysis routines was upgraded, new graphics routines were developed to enhance interactive data analysis, and routines were developed to compare alternative single-trial analysis techniques using simulated ERP data. (4) Working in conjunction with NASA Langley research scientists and simulator engineers, preparations were made for an ACFS validation study of ERP measures of workload. (5) A design specification was developed for a general purpose, computerized, workload assessment system that can function in simulators such as the ACFS.

  18. GPU-Based Simulation of Ultrasound Imaging Artifacts for Cryosurgery Training.

    PubMed

    Keelan, Robert; Shimada, Kenji; Rabin, Yoed

    2017-02-01

    This study presents an efficient computational technique for the simulation of ultrasound imaging artifacts associated with cryosurgery based on nonlinear ray tracing. This study is part of an ongoing effort to develop computerized training tools for cryosurgery, with prostate cryosurgery as a development model. The capability of performing virtual cryosurgical procedures on a variety of test cases is essential for effective surgical training. Simulated ultrasound imaging artifacts include reverberation and reflection of the cryoprobes in the unfrozen tissue, reflections caused by the freezing front, shadowing caused by the frozen region, and tissue property changes in repeated freeze-thaw cycles procedures. The simulated artifacts appear to preserve the key features observed in a clinical setting. This study displays an example of how training may benefit from toggling between the undisturbed ultrasound image, the simulated temperature field, the simulated imaging artifacts, and an augmented hybrid presentation of the temperature field superimposed on the ultrasound image. The proposed method is demonstrated on a graphic processing unit at 100 frames per second, on a mid-range personal workstation, at two orders of magnitude faster than a typical cryoprocedure. This performance is based on computation with C++ accelerated massive parallelism and its interoperability with the DirectX-rendering application programming interface.

  19. GPU-Based Simulation of Ultrasound Imaging Artifacts for Cryosurgery Training

    PubMed Central

    Keelan, Robert; Shimada, Kenji

    2016-01-01

    This study presents an efficient computational technique for the simulation of ultrasound imaging artifacts associated with cryosurgery based on nonlinear ray tracing. This study is part of an ongoing effort to develop computerized training tools for cryosurgery, with prostate cryosurgery as a development model. The capability of performing virtual cryosurgical procedures on a variety of test cases is essential for effective surgical training. Simulated ultrasound imaging artifacts include reverberation and reflection of the cryoprobes in the unfrozen tissue, reflections caused by the freezing front, shadowing caused by the frozen region, and tissue property changes in repeated freeze–thaw cycles procedures. The simulated artifacts appear to preserve the key features observed in a clinical setting. This study displays an example of how training may benefit from toggling between the undisturbed ultrasound image, the simulated temperature field, the simulated imaging artifacts, and an augmented hybrid presentation of the temperature field superimposed on the ultrasound image. The proposed method is demonstrated on a graphic processing unit at 100 frames per second, on a mid-range personal workstation, at two orders of magnitude faster than a typical cryoprocedure. This performance is based on computation with C++ accelerated massive parallelism and its interoperability with the DirectX-rendering application programming interface. PMID:26818026

  20. Graphic Arts Technology: Industrial Arts Curriculum Guide. Grades 9-12. Bulletin No. 1334 (Tentative).

    ERIC Educational Resources Information Center

    Louisiana State Dept. of Education, Baton Rouge.

    The tentative guide in graphic arts technology for senior high schools is part of a series of industrial arts curriculum materials developed by the State of Louisiana. The course is designed to provide "hands-on" experience with tools and materials along with a study of the industrial processes in graphic arts technology. In addition,…

  1. The use of graphics in the design of the human-telerobot interface

    NASA Technical Reports Server (NTRS)

    Stuart, Mark A.; Smith, Randy L.

    1989-01-01

    The Man-Systems Telerobotics Laboratory (MSTL) of NASA's Johnson Space Center employs computer graphics tools in their design and evaluation of the Flight Telerobotic Servicer (FTS) human/telerobot interface on the Shuttle and on the Space Station. It has been determined by the MSTL that the use of computer graphics can promote more expedient and less costly design endeavors. Several specific examples of computer graphics applied to the FTS user interface by the MSTL are described.

  2. Continuation of research into language concepts for the mission support environment

    NASA Technical Reports Server (NTRS)

    1991-01-01

    A concept for a more intuitive and graphically based Computation (Comp) Builder was developed. The Graphical Comp Builder Prototype was developed, which is an X Window based graphical tool that allows the user to build Comps using graphical symbols. Investigation was conducted to determine the availability and suitability of the Ada programming language for the development of future control center type software. The Space Station Freedom Project identified Ada as the desirable programming language for the development of Space Station Control Center software systems.

  3. KMWin--a convenient tool for graphical presentation of results from Kaplan-Meier survival time analysis.

    PubMed

    Gross, Arnd; Ziepert, Marita; Scholz, Markus

    2012-01-01

    Analysis of clinical studies often necessitates multiple graphical representations of the results. Many professional software packages are available for this purpose. Most packages are either only commercially available or hard to use especially if one aims to generate or customize a huge number of similar graphical outputs. We developed a new, freely available software tool called KMWin (Kaplan-Meier for Windows) facilitating Kaplan-Meier survival time analysis. KMWin is based on the statistical software environment R and provides an easy to use graphical interface. Survival time data can be supplied as SPSS (sav), SAS export (xpt) or text file (dat), which is also a common export format of other applications such as Excel. Figures can directly be exported in any graphical file format supported by R. On the basis of a working example, we demonstrate how to use KMWin and present its main functions. We show how to control the interface, customize the graphical output, and analyse survival time data. A number of comparisons are performed between KMWin and SPSS regarding graphical output, statistical output, data management and development. Although the general functionality of SPSS is larger, KMWin comprises a number of features useful for survival time analysis in clinical trials and other applications. These are for example number of cases and number of cases under risk within the figure or provision of a queue system for repetitive analyses of updated data sets. Moreover, major adjustments of graphical settings can be performed easily on a single window. We conclude that our tool is well suited and convenient for repetitive analyses of survival time data. It can be used by non-statisticians and provides often used functions as well as functions which are not supplied by standard software packages. The software is routinely applied in several clinical study groups.

  4. KMWin – A Convenient Tool for Graphical Presentation of Results from Kaplan-Meier Survival Time Analysis

    PubMed Central

    Gross, Arnd; Ziepert, Marita; Scholz, Markus

    2012-01-01

    Background Analysis of clinical studies often necessitates multiple graphical representations of the results. Many professional software packages are available for this purpose. Most packages are either only commercially available or hard to use especially if one aims to generate or customize a huge number of similar graphical outputs. We developed a new, freely available software tool called KMWin (Kaplan-Meier for Windows) facilitating Kaplan-Meier survival time analysis. KMWin is based on the statistical software environment R and provides an easy to use graphical interface. Survival time data can be supplied as SPSS (sav), SAS export (xpt) or text file (dat), which is also a common export format of other applications such as Excel. Figures can directly be exported in any graphical file format supported by R. Results On the basis of a working example, we demonstrate how to use KMWin and present its main functions. We show how to control the interface, customize the graphical output, and analyse survival time data. A number of comparisons are performed between KMWin and SPSS regarding graphical output, statistical output, data management and development. Although the general functionality of SPSS is larger, KMWin comprises a number of features useful for survival time analysis in clinical trials and other applications. These are for example number of cases and number of cases under risk within the figure or provision of a queue system for repetitive analyses of updated data sets. Moreover, major adjustments of graphical settings can be performed easily on a single window. Conclusions We conclude that our tool is well suited and convenient for repetitive analyses of survival time data. It can be used by non-statisticians and provides often used functions as well as functions which are not supplied by standard software packages. The software is routinely applied in several clinical study groups. PMID:22723912

  5. Exploring the possibility of modeling a genetic counseling guideline using agile methodology.

    PubMed

    Choi, Jeeyae

    2013-01-01

    Increased demand of genetic counseling services heightened the necessity of a computerized genetic counseling decision support system. In order to develop an effective and efficient computerized system, modeling of genetic counseling guideline is an essential step. Throughout this pilot study, Agile methodology with United Modeling Language (UML) was utilized to model a guideline. 13 tasks and 14 associated elements were extracted. Successfully constructed conceptual class and activity diagrams revealed that Agile methodology with UML was a suitable tool to modeling a genetic counseling guideline.

  6. Graphics Software Packages as Instructional Tools.

    ERIC Educational Resources Information Center

    Chiavaroli, Julius J.; Till, Ronald J.

    1985-01-01

    Graphics software can assist hearing-impaired students in visualizing and comparing ideas and can also demonstrate spatial relations and encourage creativity. Teachers and students can create and present data, diagrams, drawings, or charts quickly and accurately. (Author/CL)

  7. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  8. Spatial Modeling Tools for Cell Biology

    DTIC Science & Technology

    2006-10-01

    multiphysics modeling expertise. A graphical user interface (GUI) for CoBi, JCoBi, was written in Java and interactive 3D graphics. CoBi has been...tools (C++ and Java ) to simulate complex cell and organ biology problems. CoBi has been designed to interact with the other Bio-SPICE software...fall of 2002. VisIt supports C++, Python and Java interfaces. The C++ and Java interfaces make it possible to provide alternate user interfaces for

  9. Gnome View: A tool for visual representation of human genome data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelkey, J.E.; Thomas, G.S.; Thurman, D.A.

    1993-02-01

    GnomeView is a tool for exploring data generated by the Human Gemone Project. GnomeView provides both graphical and textural styles of data presentation: employs an intuitive window-based graphical query interface: and integrates its underlying genome databases in such a way that the user can navigate smoothly across databases and between different levels of data. This paper describes GnomeView and discusses how it addresses various genome informatics issues.

  10. Development of a User Interface for a Regression Analysis Software Tool

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert Manfred; Volden, Thomas R.

    2010-01-01

    An easy-to -use user interface was implemented in a highly automated regression analysis tool. The user interface was developed from the start to run on computers that use the Windows, Macintosh, Linux, or UNIX operating system. Many user interface features were specifically designed such that a novice or inexperienced user can apply the regression analysis tool with confidence. Therefore, the user interface s design minimizes interactive input from the user. In addition, reasonable default combinations are assigned to those analysis settings that influence the outcome of the regression analysis. These default combinations will lead to a successful regression analysis result for most experimental data sets. The user interface comes in two versions. The text user interface version is used for the ongoing development of the regression analysis tool. The official release of the regression analysis tool, on the other hand, has a graphical user interface that is more efficient to use. This graphical user interface displays all input file names, output file names, and analysis settings for a specific software application mode on a single screen which makes it easier to generate reliable analysis results and to perform input parameter studies. An object-oriented approach was used for the development of the graphical user interface. This choice keeps future software maintenance costs to a reasonable limit. Examples of both the text user interface and graphical user interface are discussed in order to illustrate the user interface s overall design approach.

  11. Implementation of a graphical user interface for the virtual multifrequency spectrometer: The VMS-Draw tool.

    PubMed

    Licari, Daniele; Baiardi, Alberto; Biczysko, Malgorzata; Egidi, Franco; Latouche, Camille; Barone, Vincenzo

    2015-02-15

    This article presents the setup and implementation of a graphical user interface (VMS-Draw) for a virtual multifrequency spectrometer. Special attention is paid to ease of use, generality and robustness for a panel of spectroscopic techniques and quantum mechanical approaches. Depending on the kind of data to be analyzed, VMS-Draw produces different types of graphical representations, including two-dimensional or three-dimesional (3D) plots, bar charts, or heat maps. Among other integrated features, one may quote the convolution of stick spectra to obtain realistic line-shapes. It is also possible to analyze and visualize, together with the structure, the molecular orbitals and/or the vibrational motions of molecular systems thanks to 3D interactive tools. On these grounds, VMS-Draw could represent a useful additional tool for spectroscopic studies integrating measurements and computer simulations. Copyright © 2014 Wiley Periodicals, Inc.

  12. Modeling biochemical transformation processes and information processing with Narrator

    PubMed Central

    Mandel, Johannes J; Fuß, Hendrik; Palfreyman, Niall M; Dubitzky, Werner

    2007-01-01

    Background Software tools that model and simulate the dynamics of biological processes and systems are becoming increasingly important. Some of these tools offer sophisticated graphical user interfaces (GUIs), which greatly enhance their acceptance by users. Such GUIs are based on symbolic or graphical notations used to describe, interact and communicate the developed models. Typically, these graphical notations are geared towards conventional biochemical pathway diagrams. They permit the user to represent the transport and transformation of chemical species and to define inhibitory and stimulatory dependencies. A critical weakness of existing tools is their lack of supporting an integrative representation of transport, transformation as well as biological information processing. Results Narrator is a software tool facilitating the development and simulation of biological systems as Co-dependence models. The Co-dependence Methodology complements the representation of species transport and transformation together with an explicit mechanism to express biological information processing. Thus, Co-dependence models explicitly capture, for instance, signal processing structures and the influence of exogenous factors or events affecting certain parts of a biological system or process. This combined set of features provides the system biologist with a powerful tool to describe and explore the dynamics of life phenomena. Narrator's GUI is based on an expressive graphical notation which forms an integral part of the Co-dependence Methodology. Behind the user-friendly GUI, Narrator hides a flexible feature which makes it relatively easy to map models defined via the graphical notation to mathematical formalisms and languages such as ordinary differential equations, the Systems Biology Markup Language or Gillespie's direct method. This powerful feature facilitates reuse, interoperability and conceptual model development. Conclusion Narrator is a flexible and intuitive systems biology tool. It is specifically intended for users aiming to construct and simulate dynamic models of biology without recourse to extensive mathematical detail. Its design facilitates mappings to different formal languages and frameworks. The combined set of features makes Narrator unique among tools of its kind. Narrator is implemented as Java software program and available as open-source from . PMID:17389034

  13. Payload crew training scheduler (PACTS) user's manual

    NASA Technical Reports Server (NTRS)

    Shipman, D. L.

    1980-01-01

    The operation of the payload specialist training scheduler (PACTS) is discussed in this user's manual which is used to schedule payload specialists for mission training on the Spacelab experiments. The PACTS program is a fully automated interactive, computerized scheduling program equipped with tutorial displays. The tutorial displays are sufficiently detailed for use by a program analyst having no computer experience. The PACTS program is designed to operate on the UNIVAC 1108 computer system, and has the capability to load output into a PDP 11/45 Interactive Graphics Display System for printing schedules. The program has the capacity to handle up to three overlapping Spacelab missions.

  14. HNET - A National Computerized Health Network

    PubMed Central

    Casey, Mark; Hamilton, Richard

    1988-01-01

    The HNET system demonstrated conceptually and technically a national text (and limited bit mapped graphics) computer network for use between innovative members of the health care industry. The HNET configuration of a leased high speed national packet switching network connecting any number of mainframe, mini, and micro computers was unique in it's relatively low capital costs and freedom from obsolescence. With multiple simultaneous conferences, databases, bulletin boards, calendars, and advanced electronic mail and surveys, it is marketable to innovative hospitals, clinics, physicians, health care associations and societies, nurses, multisite research projects libraries, etc.. Electronic publishing and education capabilities along with integrated voice and video transmission are identified as future enhancements.

  15. The effect of using graphic organizers in the teaching of standard biology

    NASA Astrophysics Data System (ADS)

    Pepper, Wade Louis, Jr.

    This study was conducted to determine if the use of graphic organizers in the teaching of standard biology would increase student achievement, involvement and quality of activities. The subjects were 10th grade standard biology students in a large southern inner city high school. The study was conducted over a six-week period in an instructional setting using action research as the investigative format. After calculation of the homogeneity between classes, random selection was used to determine the graphic organizer class and the control class. The graphic organizer class was taught unit material through a variety of instructional methods along with the use of teacher generated graphic organizers. The control class was taught the same unit material using the same instructional methods, but without the use of graphic organizers. Data for the study were gathered from in-class written assignments, teacher-generated tests and text-generated tests, and rubric scores of an out-of-class written assignment and project. Also, data were gathered from student reactions, comments, observations and a teacher's research journal. Results were analyzed using descriptive statistics and qualitative interpretation. By comparing statistical results, it was determined that the use of graphic organizers did not make a statistically significant difference in the understanding of biological concepts and retention of factual information. Furthermore, the use of graphic organizers did not make a significant difference in motivating students to fulfill all class assignments with quality efforts and products. However, based upon student reactions and comments along with observations by the researcher, graphic organizers were viewed by the students as a favorable and helpful instructional tool. In lieu of statistical results, student gains from instructional activities using graphic organizers were positive and merit the continuation of their use as an instructional tool.

  16. Computerized assessment of placental calcification post-ultrasound: a novel software tool.

    PubMed

    Moran, M; Higgins, M; Zombori, G; Ryan, J; McAuliffe, F M

    2013-05-01

    Placental calcification is associated with an increased risk of perinatal morbidity and mortality. The subjectivity of current ultrasound methods of assessment of placental calcification indicates that a more objective method is required. The aim of this study was to correlate the percentage of calcification defined by the clinician using a new software tool for calculating the extent of placental calcification with traditional ultrasound methods and with pregnancy outcome. Ninety placental images were individually assessed. An upper threshold was defined, based on high intensity, to quantify calcification within the placenta. Output metrics were then produced including the overall percentage of calcification with respect to the total number of pixels within the region of interest. The results were correlated with traditional ultrasound methods of assessment of placental calcification and with pregnancy outcome. The results demonstrate a significant correlation between placental calcification, as defined using the software, and traditional methods of Grannum grading of placental calcification. Whilst correlation with perinatal outcome and cord pH was not significant as a result of small numbers, patients with placental calcification assessed using the computerized software at the upper quartile had higher rates of poor perinatal outcome when compared with those at the lower quartile (8/22 (36%) vs 3/23 (13%); P = 0.069). These results suggest that this computerized software tool has the potential to become an alternative method of assessing placental calcification. Copyright © 2012 ISUOG. Published by John Wiley & Sons Ltd.

  17. The pits and falls of graphical presentation.

    PubMed

    Sperandei, Sandro

    2014-01-01

    Graphics are powerful tools to communicate research results and to gain information from data. However, researchers should be careful when deciding which data to plot and the type of graphic to use, as well as other details. The consequence of bad decisions in these features varies from making research results unclear to distortions of these results, through the creation of "chartjunk" with useless information. This paper is not another tutorial about "good graphics" and "bad graphics". Instead, it presents guidelines for graphic presentation of research results and some uncommon, but useful examples to communicate basic and complex data types, especially multivariate model results, which are commonly presented only by tables. By the end, there are no answers here, just ideas meant to inspire others on how to create their own graphics.

  18. Designing a Graphical Decision Support Tool to Improve System Acquisition Decisions

    DTIC Science & Technology

    2009-06-01

    relationships within the data [9]. Displaying acquisition data in a graphical manner was chosen because graphical formats, in general, have been...acquisition plan which includes information pertaining to the acquisition objectives, the required capability of the system, design trade-off, budgeting...which introduce artificial neural networks to approximate the real world experience of an acquisition manager [8]. However, these strategies lack a

  19. Three varieties of realism in computer graphics

    NASA Astrophysics Data System (ADS)

    Ferwerda, James A.

    2003-06-01

    This paper describes three varieties of realism that need to be considered in evaluating computer graphics images and defines the criteria that need to be met if each kind of realism is to be achieved. The paper introduces a conceptual framework for thinking about realism in images, and describes a set of research tools for measuring image realism and assessing its value in graphics applications.

  20. Manufacturing Execution Systems: Examples of Performance Indicator and Operational Robustness Tools.

    PubMed

    Gendre, Yannick; Waridel, Gérard; Guyon, Myrtille; Demuth, Jean-François; Guelpa, Hervé; Humbert, Thierry

    Manufacturing Execution Systems (MES) are computerized systems used to measure production performance in terms of productivity, yield, and quality. In the first part, performance indicator and overall equipment effectiveness (OEE), process robustness tools and statistical process control are described. The second part details some tools to help process robustness and control by operators by preventing deviations from target control charts. MES was developed by Syngenta together with CIMO for automation.

  1. Knowledge From Pictures (KFP)

    NASA Technical Reports Server (NTRS)

    Truszkowski, Walt; Paterra, Frank; Bailin, Sidney

    1993-01-01

    The old maxim goes: 'A picture is worth a thousand words'. The objective of the research reported in this paper is to demonstrate this idea as it relates to the knowledge acquisition process and the automated development of an expert system's rule base. A prototype tool, the Knowledge From Pictures (KFP) tool, has been developed which configures an expert system's rule base by an automated analysis of and reasoning about a 'picture', i.e., a graphical representation of some target system to be supported by the diagnostic capabilities of the expert system under development. This rule base, when refined, could then be used by the expert system for target system monitoring and fault analysis in an operational setting. Most people, when faced with the problem of understanding the behavior of a complicated system, resort to the use of some picture or graphical representation of the system as an aid in thinking about it. This depiction provides a means of helping the individual to visualize the bahavior and dynamics of the system under study. An analysis of the picture augmented with the individual's background information, allows the problem solver to codify knowledge about the system. This knowledge can, in turn, be used to develop computer programs to automatically monitor the system's performance. The approach taken is this research was to mimic this knowledge acquisition paradigm. A prototype tool was developed which provides the user: (1) a mechanism for graphically representing sample system-configurations appropriate for the domain, and (2) a linguistic device for annotating the graphical representation with the behaviors and mutual influences of the components depicted in the graphic. The KFP tool, reasoning from the graphical depiction along with user-supplied annotations of component behaviors and inter-component influences, generates a rule base that could be used in automating the fault detection, isolation, and repair of the system.

  2. Global Precipitation Mission Visualization Tool

    NASA Technical Reports Server (NTRS)

    Schwaller, Mathew

    2011-01-01

    The Global Precipitation Mission (GPM) software provides graphic visualization tools that enable easy comparison of ground- and space-based radar observations. It was initially designed to compare ground radar reflectivity from operational, ground-based, S- and C-band meteorological radars with comparable measurements from the Tropical Rainfall Measuring Mission (TRMM) satellite's precipitation radar instrument. This design is also applicable to other groundbased and space-based radars, and allows both ground- and space-based radar data to be compared for validation purposes. The tool creates an operational system that routinely performs several steps. It ingests satellite radar data (precipitation radar data from TRMM) and groundbased meteorological radar data from a number of sources. Principally, the ground radar data comes from national networks of weather radars (see figure). The data ingested by the visualization tool must conform to the data formats used in GPM Validation Network Geometry-matched data product generation. The software also performs match-ups of the radar volume data for the ground- and space-based data, as well as statistical and graphical analysis (including two-dimensional graphical displays) on the match-up data. The visualization tool software is written in IDL, and can be operated either in the IDL development environment or as a stand-alone executable function.

  3. Computerization of guidelines: a knowledge specification method to convert text to detailed decision tree for electronic implementation.

    PubMed

    Aguirre-Junco, Angel-Ricardo; Colombet, Isabelle; Zunino, Sylvain; Jaulent, Marie-Christine; Leneveut, Laurence; Chatellier, Gilles

    2004-01-01

    The initial step for the computerization of guidelines is the knowledge specification from the prose text of guidelines. We describe a method of knowledge specification based on a structured and systematic analysis of text allowing detailed specification of a decision tree. We use decision tables to validate the decision algorithm and decision trees to specify and represent this algorithm, along with elementary messages of recommendation. Edition tools are also necessary to facilitate the process of validation and workflow between expert physicians who will validate the specified knowledge and computer scientist who will encode the specified knowledge in a guide-line model. Applied to eleven different guidelines issued by an official agency, the method allows a quick and valid computerization and integration in a larger decision support system called EsPeR (Personalized Estimate of Risks). The quality of the text guidelines is however still to be developed further. The method used for computerization could help to define a framework usable at the initial step of guideline development in order to produce guidelines ready for electronic implementation.

  4. Interactive Video Courseware for Graphic Communications Teachers and Students.

    ERIC Educational Resources Information Center

    Sanders, Mark

    1985-01-01

    At Virginia Polytechnic Institute and State University, interactive video serves both as an instructional tool and a project for creative students in graphic communications. The package facilitates courseware development and teaches students simultaneously about microcomputer and video technology. (SK)

  5. Graphics Software For VT Terminals

    NASA Technical Reports Server (NTRS)

    Wang, Caroline

    1991-01-01

    VTGRAPH graphics software tool for DEC/VT computer terminal or terminals compatible with it, widely used by government and industry. Callable in FORTRAN or C language, library program enabling user to cope with many computer environments in which VT terminals used for window management and graphic systems. Provides PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. User can easily design more-friendly user-interface programs and design PLOT10 programs on VT terminals with different computer systems. Requires ReGis graphics set terminal and FORTRAN compiler.

  6. FusionAnalyser: a new graphical, event-driven tool for fusion rearrangements discovery

    PubMed Central

    Piazza, Rocco; Pirola, Alessandra; Spinelli, Roberta; Valletta, Simona; Redaelli, Sara; Magistroni, Vera; Gambacorti-Passerini, Carlo

    2012-01-01

    Gene fusions are common driver events in leukaemias and solid tumours; here we present FusionAnalyser, a tool dedicated to the identification of driver fusion rearrangements in human cancer through the analysis of paired-end high-throughput transcriptome sequencing data. We initially tested FusionAnalyser by using a set of in silico randomly generated sequencing data from 20 known human translocations occurring in cancer and subsequently using transcriptome data from three chronic and three acute myeloid leukaemia samples. in all the cases our tool was invariably able to detect the presence of the correct driver fusion event(s) with high specificity. In one of the acute myeloid leukaemia samples, FusionAnalyser identified a novel, cryptic, in-frame ETS2–ERG fusion. A fully event-driven graphical interface and a flexible filtering system allow complex analyses to be run in the absence of any a priori programming or scripting knowledge. Therefore, we propose FusionAnalyser as an efficient and robust graphical tool for the identification of functional rearrangements in the context of high-throughput transcriptome sequencing data. PMID:22570408

  7. FusionAnalyser: a new graphical, event-driven tool for fusion rearrangements discovery.

    PubMed

    Piazza, Rocco; Pirola, Alessandra; Spinelli, Roberta; Valletta, Simona; Redaelli, Sara; Magistroni, Vera; Gambacorti-Passerini, Carlo

    2012-09-01

    Gene fusions are common driver events in leukaemias and solid tumours; here we present FusionAnalyser, a tool dedicated to the identification of driver fusion rearrangements in human cancer through the analysis of paired-end high-throughput transcriptome sequencing data. We initially tested FusionAnalyser by using a set of in silico randomly generated sequencing data from 20 known human translocations occurring in cancer and subsequently using transcriptome data from three chronic and three acute myeloid leukaemia samples. in all the cases our tool was invariably able to detect the presence of the correct driver fusion event(s) with high specificity. In one of the acute myeloid leukaemia samples, FusionAnalyser identified a novel, cryptic, in-frame ETS2-ERG fusion. A fully event-driven graphical interface and a flexible filtering system allow complex analyses to be run in the absence of any a priori programming or scripting knowledge. Therefore, we propose FusionAnalyser as an efficient and robust graphical tool for the identification of functional rearrangements in the context of high-throughput transcriptome sequencing data.

  8. Design strategies and functionality of the Visual Interface for Virtual Interaction Development (VIVID) tool

    NASA Technical Reports Server (NTRS)

    Nguyen, Lac; Kenney, Patrick J.

    1993-01-01

    Development of interactive virtual environments (VE) has typically consisted of three primary activities: model (object) development, model relationship tree development, and environment behavior definition and coding. The model and relationship tree development activities are accomplished with a variety of well-established graphic library (GL) based programs - most utilizing graphical user interfaces (GUI) with point-and-click interactions. Because of this GUI format, little programming expertise on the part of the developer is necessary to create the 3D graphical models or to establish interrelationships between the models. However, the third VE development activity, environment behavior definition and coding, has generally required the greatest amount of time and programmer expertise. Behaviors, characteristics, and interactions between objects and the user within a VE must be defined via command line C coding prior to rendering the environment scenes. In an effort to simplify this environment behavior definition phase for non-programmers, and to provide easy access to model and tree tools, a graphical interface and development tool has been created. The principal thrust of this research is to effect rapid development and prototyping of virtual environments. This presentation will discuss the 'Visual Interface for Virtual Interaction Development' (VIVID) tool; an X-Windows based system employing drop-down menus for user selection of program access, models, and trees, behavior editing, and code generation. Examples of these selection will be highlighted in this presentation, as will the currently available program interfaces. The functionality of this tool allows non-programming users access to all facets of VE development while providing experienced programmers with a collection of pre-coded behaviors. In conjunction with its existing, interfaces and predefined suite of behaviors, future development plans for VIVID will be described. These include incorporation of dual user virtual environment enhancements, tool expansion, and additional behaviors.

  9. Hardwood Lumber Edger and Trimmer Training System

    Treesearch

    D. Earl Kline; Eugene M. Wengert; Philip A. Araman; Powsiri Klinkhachorn

    1992-01-01

    This paper describes a computerized hardwood lumber edger and trimming training system. The purpose of the training system is to help edger and trimmer operators and sawmill managers better understand how hardwood lumber grade, surface measure, and price interact to affect lumber value. The training system can be used both as a training tool and as a testing tool. As a...

  10. [Use of the computer as a tool for the implementation of the nursing process--the experience of the Sâo Paulo/UNIFESP].

    PubMed

    de Barros, Alba Lúcia; Fakih, Flávio Trevisani; Michel, Jeanne Liliane

    2002-01-01

    This article reports the pathway used to build a prototype of a computer nurse's clinical decision making support system, using NANDA, NIC and NOC classifications, as an auxiliary tool in the insertion of nursing data in the computerized patient record of Hospital São Paulo/UNIFESP.

  11. Development and Assessment of a New 3D Neuroanatomy Teaching Tool for MRI Training

    ERIC Educational Resources Information Center

    Drapkin, Zachary A.; Lindgren, Kristen A.; Lopez, Michael J.; Stabio, Maureen E.

    2015-01-01

    A computerized three-dimensional (3D) neuroanatomy teaching tool was developed for training medical students to identify subcortical structures on a magnetic resonance imaging (MRI) series of the human brain. This program allows the user to transition rapidly between two-dimensional (2D) MRI slices, 3D object composites, and a combined model in…

  12. GPFrontend and GPGraphics: graphical analysis tools for genetic association studies.

    PubMed

    Uebe, Steffen; Pasutto, Francesca; Krumbiegel, Mandy; Schanze, Denny; Ekici, Arif B; Reis, André

    2010-09-21

    Most software packages for whole genome association studies are non-graphical, purely text based programs originally designed to run with UNIX-like operating systems. Graphical output is often not intended or supposed to be performed with other command line tools, e.g. gnuplot. Using the Microsoft .NET 2.0 platform and Visual Studio 2005, we have created a graphical software package to analyze data from microarray whole genome association studies, both for a DNA-pooling based approach as well as regular single sample data. Part of this package was made to integrate with GenePool 0.8.2, a previously existing software suite for GNU/Linux systems, which we have modified to run in a Microsoft Windows environment. Further modifications cause it to generate some additional data. This enables GenePool to interact with the .NET parts created by us. The programs we developed are GPFrontend, a graphical user interface and frontend to use GenePool and create metadata files for it, and GPGraphics, a program to further analyze and graphically evaluate output of different WGA analysis programs, among them also GenePool. Our programs enable regular MS Windows users without much experience in bioinformatics to easily visualize whole genome data from a variety of sources.

  13. Software For Graphical Representation Of A Network

    NASA Technical Reports Server (NTRS)

    Mcallister, R. William; Mclellan, James P.

    1993-01-01

    System Visualization Tool (SVT) computer program developed to provide systems engineers with means of graphically representing networks. Generates diagrams illustrating structures and states of networks defined by users. Provides systems engineers powerful tool simplifing analysis of requirements and testing and maintenance of complex software-controlled systems. Employs visual models supporting analysis of chronological sequences of requirements, simulation data, and related software functions. Applied to pneumatic, hydraulic, and propellant-distribution networks. Used to define and view arbitrary configurations of such major hardware components of system as propellant tanks, valves, propellant lines, and engines. Also graphically displays status of each component. Advantage of SVT: utilizes visual cues to represent configuration of each component within network. Written in Turbo Pascal(R), version 5.0.

  14. G2H--graphics-to-haptic virtual environment development tool for PC's.

    PubMed

    Acosta, E; Temkin, B; Krummel, T M; Heinrichs, W L

    2000-01-01

    For surgical training and preparations, the existing surgical virtual environments have shown great improvement. However, these improvements are more in the visual aspect. The incorporation of haptics into virtual reality base surgical simulations would enhance the sense of realism greatly. To aid in the development of the haptic surgical virtual environment we have created a graphics to haptic, G2H, virtual environment developer tool. G2H transforms graphical virtual environments (created or imported) to haptic virtual environments without programming. The G2H capability has been demonstrated using the complex 3D pelvic model of Lucy 2.0, the Stanford Visible Female. The pelvis was made haptic using G2H without any further programming effort.

  15. mcaGUI: microbial community analysis R-Graphical User Interface (GUI).

    PubMed

    Copeland, Wade K; Krishnan, Vandhana; Beck, Daniel; Settles, Matt; Foster, James A; Cho, Kyu-Chul; Day, Mitch; Hickey, Roxana; Schütte, Ursel M E; Zhou, Xia; Williams, Christopher J; Forney, Larry J; Abdo, Zaid

    2012-08-15

    Microbial communities have an important role in natural ecosystems and have an impact on animal and human health. Intuitive graphic and analytical tools that can facilitate the study of these communities are in short supply. This article introduces Microbial Community Analysis GUI, a graphical user interface (GUI) for the R-programming language (R Development Core Team, 2010). With this application, researchers can input aligned and clustered sequence data to create custom abundance tables and perform analyses specific to their needs. This GUI provides a flexible modular platform, expandable to include other statistical tools for microbial community analysis in the future. The mcaGUI package and source are freely available as part of Bionconductor at http://www.bioconductor.org/packages/release/bioc/html/mcaGUI.html

  16. Applications of the pipeline environment for visual informatics and genomics computations

    PubMed Central

    2011-01-01

    Background Contemporary informatics and genomics research require efficient, flexible and robust management of large heterogeneous data, advanced computational tools, powerful visualization, reliable hardware infrastructure, interoperability of computational resources, and detailed data and analysis-protocol provenance. The Pipeline is a client-server distributed computational environment that facilitates the visual graphical construction, execution, monitoring, validation and dissemination of advanced data analysis protocols. Results This paper reports on the applications of the LONI Pipeline environment to address two informatics challenges - graphical management of diverse genomics tools, and the interoperability of informatics software. Specifically, this manuscript presents the concrete details of deploying general informatics suites and individual software tools to new hardware infrastructures, the design, validation and execution of new visual analysis protocols via the Pipeline graphical interface, and integration of diverse informatics tools via the Pipeline eXtensible Markup Language syntax. We demonstrate each of these processes using several established informatics packages (e.g., miBLAST, EMBOSS, mrFAST, GWASS, MAQ, SAMtools, Bowtie) for basic local sequence alignment and search, molecular biology data analysis, and genome-wide association studies. These examples demonstrate the power of the Pipeline graphical workflow environment to enable integration of bioinformatics resources which provide a well-defined syntax for dynamic specification of the input/output parameters and the run-time execution controls. Conclusions The LONI Pipeline environment http://pipeline.loni.ucla.edu provides a flexible graphical infrastructure for efficient biomedical computing and distributed informatics research. The interactive Pipeline resource manager enables the utilization and interoperability of diverse types of informatics resources. The Pipeline client-server model provides computational power to a broad spectrum of informatics investigators - experienced developers and novice users, user with or without access to advanced computational-resources (e.g., Grid, data), as well as basic and translational scientists. The open development, validation and dissemination of computational networks (pipeline workflows) facilitates the sharing of knowledge, tools, protocols and best practices, and enables the unbiased validation and replication of scientific findings by the entire community. PMID:21791102

  17. Artwork Interactive Design System (AIDS) program description

    NASA Technical Reports Server (NTRS)

    Johnson, B. T.; Taylor, J. F.

    1976-01-01

    An artwork interactive design system is described which provides the microelectronic circuit designer/engineer a tool to perform circuit design, automatic layout modification, standard cell design, and artwork verification at a graphics computer terminal using a graphics tablet at the designer/computer interface.

  18. Graphic Organizers for Secondary Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Singleton, Sabrina M.; Filce, Hollie Gabler

    2015-01-01

    Research suggests students with learning disabilities often have trouble connecting new and prior knowledge, distinguishing essential and nonessential information, and applying comprehension strategies (DiCecco & Gleason, 2002; Vaughn & Edmonds, 2006). Graphic organizers have been suggested as tools educators can use to facilitate critical…

  19. Model Evaluation of Continuous Data Pharmacometric Models: Metrics and Graphics

    PubMed Central

    Nguyen, THT; Mouksassi, M‐S; Holford, N; Al‐Huniti, N; Freedman, I; Hooker, AC; John, J; Karlsson, MO; Mould, DR; Pérez Ruixo, JJ; Plan, EL; Savic, R; van Hasselt, JGC; Weber, B; Zhou, C; Comets, E

    2017-01-01

    This article represents the first in a series of tutorials on model evaluation in nonlinear mixed effect models (NLMEMs), from the International Society of Pharmacometrics (ISoP) Model Evaluation Group. Numerous tools are available for evaluation of NLMEM, with a particular emphasis on visual assessment. This first basic tutorial focuses on presenting graphical evaluation tools of NLMEM for continuous data. It illustrates graphs for correct or misspecified models, discusses their pros and cons, and recalls the definition of metrics used. PMID:27884052

  20. Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation

    PubMed Central

    Sklarin, Nancy T.; Granovsky, Svetlana; O'Reilly, Eileen M.; Zelenetz, Andrew D.

    2011-01-01

    Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years. PMID:22043182

  1. Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation.

    PubMed

    Sklarin, Nancy T; Granovsky, Svetlana; O'Reilly, Eileen M; Zelenetz, Andrew D

    2011-07-01

    Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years.

  2. Integrating Commercial Off-The-Shelf (COTS) graphics and extended memory packages with CLIPS

    NASA Technical Reports Server (NTRS)

    Callegari, Andres C.

    1990-01-01

    This paper addresses the question of how to mix CLIPS with graphics and how to overcome PC's memory limitations by using the extended memory available in the computer. By adding graphics and extended memory capabilities, CLIPS can be converted into a complete and powerful system development tool, on the other most economical and popular computer platform. New models of PCs have amazing processing capabilities and graphic resolutions that cannot be ignored and should be used to the fullest of their resources. CLIPS is a powerful expert system development tool, but it cannot be complete without the support of a graphics package needed to create user interfaces and general purpose graphics, or without enough memory to handle large knowledge bases. Now, a well known limitation on the PC's is the usage of real memory which limits CLIPS to use only 640 Kb of real memory, but now that problem can be solved by developing a version of CLIPS that uses extended memory. The user has access of up to 16 MB of memory on 80286 based computers and, practically, all the available memory (4 GB) on computers that use the 80386 processor. So if we give CLIPS a self-configuring graphics package that will automatically detect the graphics hardware and pointing device present in the computer, and we add the availability of the extended memory that exists in the computer (with no special hardware needed), the user will be able to create more powerful systems at a fraction of the cost and on the most popular, portable, and economic platform available such as the PC platform.

  3. A boxplot for circular data.

    PubMed

    Buttarazzi, Davide; Pandolfo, Giuseppe; Porzio, Giovanni C

    2018-05-21

    The box-and-whiskers plot is an extraordinary graphical tool that provides a quick visual summary of an observed distribution. In spite of its many extensions, a really suitable boxplot to display circular data is not yet available. Thanks to its simplicity and strong visual impact, such a tool would be especially useful in all fields where circular measures arise: biometrics, astronomy, environmetrics, Earth sciences, to cite just a few. For this reason, in line with Tukey's original idea, a Tukey-like circular boxplot is introduced. Several simulated and real datasets arising in biology are used to illustrate the proposed graphical tool. © 2018, The International Biometric Society.

  4. Interactive color-graphics interface for energy-monitoring and -control systems. Final report, October 1979-September 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canfield, K.J.

    1984-05-01

    An EMCS (Energy Monitoring and Control System) can be described as a system that automatically takes care of routine operation of equipment and provides centralized reporting and override capabilities. Equipment controlled by an EMCS would be heating, ventilating, and air conditioning (HVAC) equipment, air compressors, and small package boiler units. The EMCS would obtain raw information (data) from sensors associated with the equipment and massage the data into useful information. The information obtained from the sensors plus additional information available to the EMCS would be used to control the equipment. The information would also be available to the operator inmore » the form of reports or in response to operator commands for specific information. EMCS are computerized systems that control and monitor energy consuming and producing equipment at Naval facilities. The larger systems have been installed with color-graphics cathode ray tube operator consoles to provide better information to the personnel operating these systems. This report summarizes the work done on defining an adequate operator console and recommends changes to the existing EMCS Guide Specifications.« less

  5. [Evaluation of an automated pH-monitor and its logic of calculation].

    PubMed

    Ducrotté, P; Hubin, M; Xin, H; Roussignol, C; Denis, P

    1990-01-01

    The aim of this study was to compare the results of 3-hour postprandial esophageal pH recordings obtained simultaneously from a standard Beckmann pH recorder and a commercially available fully automated pH recording device, "pH 60" in 30 subjects. Both apparatuses were connected to the same pH probe and to a unique chart recorder to obtain simultaneous pH graphic tracings. The percentage of time between each pH level below pH 5, the percentage of time with pH less than 4 and Kaye's score were determined hourly and for the overall recording time. The pH graphic traces in both apparatuses were strictly identical demonstrating the accuracy of the analog-to-digital converter and the memory module to record pH changes. Moreover, we found a significant correlation (p less than 0.01) and a good overall agreement for all compared parameters between manual and computerized analysis. This study documents that the commercially available ambulatory esophageal pH instrument studied produces accurate data for the diagnosis of gastroesophageal reflux.

  6. An Interactive Educational Tool for Compressible Aerodynamics

    NASA Technical Reports Server (NTRS)

    Benson, Thomas J.

    1994-01-01

    A workstation-based interactive educational tool was developed to aid in the teaching of undergraduate compressible aerodynamics. The tool solves for the supersonic flow past a wedge using the equations found in NACA 1135. The student varies the geometry or flow conditions through a graphical user interface and the new conditions are calculated immediately. Various graphical formats present the variation of flow results to the student. One such format leads the student to the generation of some of the graphs found in NACA-1135. The tool includes interactive questions and answers to aid in both the use of the tool and to develop an understanding of some of the complexities of compressible aerodynamics. A series of help screens make the simulator easy to learn and use. This paper will detail the numerical methods used in the tool and describe how it can be used and modified.

  7. The use of interpractive graphic displays for interpretation of surface design parameters

    NASA Technical Reports Server (NTRS)

    Talcott, N. A., Jr.

    1981-01-01

    An interactive computer graphics technique known as the Graphic Display Data method has been developed to provide a convenient means for rapidly interpreting large amounts of surface design data. The display technique should prove valuable in such disciplines as aerodynamic analysis, structural analysis, and experimental data analysis. To demonstrate the system's features, an example is presented of the Graphic Data Display method used as an interpretive tool for radiation equilibrium temperature distributions over the surface of an aerodynamic vehicle. Color graphic displays were also examined as a logical extension of the technique to improve its clarity and to allow the presentation of greater detail in a single display.

  8. Simulation of Robot Kinematics Using Interactive Computer Graphics.

    ERIC Educational Resources Information Center

    Leu, M. C.; Mahajan, R.

    1984-01-01

    Development of a robot simulation program based on geometric transformation softwares available in most computer graphics systems and program features are described. The program can be extended to simulate robots coordinating with external devices (such as tools, fixtures, conveyors) using geometric transformations to describe the…

  9. Design and Implementation of a Tool for Teaching Programming.

    ERIC Educational Resources Information Center

    Goktepe, Mesut; And Others

    1989-01-01

    Discussion of the use of computers in education focuses on a graphics-based system for teaching the Pascal programing language for problem solving. Topics discussed include user interface; notification based systems; communication processes; object oriented programing; workstations; graphics architecture; and flowcharts. (18 references) (LRW)

  10. Graphic Representations as Tools for Decision Making.

    ERIC Educational Resources Information Center

    Howard, Judith

    2001-01-01

    Focuses on the use of graphic representations to enable students to improve their decision making skills in the social studies. Explores three visual aids used in assisting students with decision making: (1) the force field; (2) the decision tree; and (3) the decision making grid. (CMK)

  11. A graphics approach in the design of the dual air density Explorer satellites

    NASA Technical Reports Server (NTRS)

    Mcdougal, D. S.

    1975-01-01

    A computer program was developed to generate a graphics display of the Dual Air Density (DAD) Explorer satellites which aids in the engineering and scientific design. The program displays a two-dimensional view of both spacecraft and their surface features from any direction. The graphics have been an indispensable tool in the design, analysis, and understanding of the critical locations of the various surface features for both satellites.

  12. The Galker test of speech reception in noise; associations with background variables, middle ear status, hearing, and language in Danish preschool children.

    PubMed

    Lauritsen, Maj-Britt Glenn; Söderström, Margareta; Kreiner, Svend; Dørup, Jens; Lous, Jørgen

    2016-01-01

    We tested "the Galker test", a speech reception in noise test developed for primary care for Danish preschool children, to explore if the children's ability to hear and understand speech was associated with gender, age, middle ear status, and the level of background noise. The Galker test is a 35-item audio-visual, computerized word discrimination test in background noise. Included were 370 normally developed children attending day care center. The children were examined with the Galker test, tympanometry, audiometry, and the Reynell test of verbal comprehension. Parents and daycare teachers completed questionnaires on the children's ability to hear and understand speech. As most of the variables were not assessed using interval scales, non-parametric statistics (Goodman-Kruskal's gamma) were used for analyzing associations with the Galker test score. For comparisons, analysis of variance (ANOVA) was used. Interrelations were adjusted for using a non-parametric graphic model. In unadjusted analyses, the Galker test was associated with gender, age group, language development (Reynell revised scale), audiometry, and tympanometry. The Galker score was also associated with the parents' and day care teachers' reports on the children's vocabulary, sentence construction, and pronunciation. Type B tympanograms were associated with a mean hearing 5-6dB below that of than type A, C1, or C2. In the graphic analysis, Galker scores were closely and significantly related to Reynell test scores (Gamma (G)=0.35), the children's age group (G=0.33), and the day care teachers' assessment of the children's vocabulary (G=0.26). The Galker test of speech reception in noise appears promising as an easy and quick tool for evaluating preschool children's understanding of spoken words in noise, and it correlated well with the day care teachers' reports and less with the parents' reports. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. The Real Time Display Builder (RTDB)

    NASA Technical Reports Server (NTRS)

    Kindred, Erick D.; Bailey, Samuel A., Jr.

    1989-01-01

    The Real Time Display Builder (RTDB) is a prototype interactive graphics tool that builds logic-driven displays. These displays reflect current system status, implement fault detection algorithms in real time, and incorporate the operational knowledge of experienced flight controllers. RTDB utilizes an object-oriented approach that integrates the display symbols with the underlying operational logic. This approach allows the user to specify the screen layout and the driving logic as the display is being built. RTDB is being developed under UNIX in C utilizing the MASSCOMP graphics environment with appropriate functional separation to ease portability to other graphics environments. RTDB grew from the need to develop customized real-time data-driven Space Shuttle systems displays. One display, using initial functionality of the tool, was operational during the orbit phase of STS-26 Discovery. RTDB is being used to produce subsequent displays for the Real Time Data System project currently under development within the Mission Operations Directorate at NASA/JSC. The features of the tool, its current state of development, and its applications are discussed.

  14. Development and Validation of the Computerized Family Relations Test for Children.

    PubMed

    Skoczń, Ilona; Cieciuch, Jan; Oud, Johan H L; Welzen, Kai

    2015-01-01

    The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT) for children. This test assesses the quality of family relationships with the mother and father from a child's perspective. The CFRT consists of six scales relating to control (Restrictiveness and Justice), and support (Affection, Vulnerability, Acknowledgment, and Trust) within the family relationships. CFRT is an innovative approach to the Dutch Nijmegen Family Relations Test (NFRT) developed by Oud and Welzen (1989). The administration of the test has been computerized and graphical representations of female and male silhouettes were included to facilitate the child's parental identification. In total, 404 primary school children, aged 8 to 13 years (M = 11.0; SD = 1.17), took part in this study. The CFRT's reliability was assessed by McDonald's omega coefficients, and ranged from 0.71 to 0.86, except for Vulnerability which achieved the lowest reliability 0.57 for mothers' ratings and 0.56 for fathers' ratings. The test-retest procedure revealed higher stability for the ratings on father-child relationships of 0.71 compared to mother-child relationships of 0.67. Confirmatory factor analysis indicated that a six-factor model provided an adequate fit. Measurement invariance across the children's assessments of the quality of family relationships was achieved. The construct validity of CFRT was assessed by examining differences in the child's ratings of the relationships with the mother and father, the child's gender, and associations of CFRT scales with other variables such as depression, anxiety symptoms, and prosocial behavior.

  15. Development and Validation of the Computerized Family Relations Test for Children

    PubMed Central

    Skoczń, Ilona; Cieciuch, Jan; Oud, Johan H. L.; Welzen, Kai

    2015-01-01

    The aim of the present study was to develop and investigate the psychometric properties of the Computerized Family Relations Test (CFRT) for children. This test assesses the quality of family relationships with the mother and father from a child’s perspective. The CFRT consists of six scales relating to control (Restrictiveness and Justice), and support (Affection, Vulnerability, Acknowledgment, and Trust) within the family relationships. CFRT is an innovative approach to the Dutch Nijmegen Family Relations Test (NFRT) developed by Oud and Welzen (1989). The administration of the test has been computerized and graphical representations of female and male silhouettes were included to facilitate the child’s parental identification. In total, 404 primary school children, aged 8 to 13 years (M = 11.0; SD = 1.17), took part in this study. The CFRT’s reliability was assessed by McDonald’s omega coefficients, and ranged from 0.71 to 0.86, except for Vulnerability which achieved the lowest reliability 0.57 for mothers’ ratings and 0.56 for fathers’ ratings. The test–retest procedure revealed higher stability for the ratings on father-child relationships of 0.71 compared to mother-child relationships of 0.67. Confirmatory factor analysis indicated that a six-factor model provided an adequate fit. Measurement invariance across the children’s assessments of the quality of family relationships was achieved. The construct validity of CFRT was assessed by examining differences in the child’s ratings of the relationships with the mother and father, the child’s gender, and associations of CFRT scales with other variables such as depression, anxiety symptoms, and prosocial behavior. PMID:26617538

  16. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    PubMed Central

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468

  17. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    PubMed

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  18. Impact of implementing electronic clinical practice guidelines for the diagnosis, control and treatment of cardiovascular risk factors: A pre-post controlled study.

    PubMed

    Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M

    To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. Prediction of survival without morbidity for infants born at under 33 weeks gestational age: a user-friendly graphical tool.

    PubMed

    Shah, Prakesh S; Ye, Xiang Y; Synnes, Anne; Rouvinez-Bouali, Nicole; Yee, Wendy; Lee, Shoo K

    2012-03-01

    To develop models and a graphical tool for predicting survival to discharge without major morbidity for infants with a gestational age (GA) at birth of 22-32 weeks using infant information at birth. Retrospective cohort study. Canadian Neonatal Network data for 2003-2008 were utilised. Neonates born between 22 and 32 weeks gestation admitted to neonatal intensive care units in Canada. Survival to discharge without major morbidity defined as survival without severe neurological injury (intraventricular haemorrhage grade 3 or 4 or periventricular leukomalacia), severe retinopathy (stage 3 or higher), necrotising enterocolitis (stage 2 or 3) or chronic lung disease. Of the 17 148 neonates who met the eligibility criteria, 65% survived without major morbidity. Sex and GA at birth were significant predictors. Birth weight (BW) had a significant but non-linear effect on survival without major morbidity. Although maternal information characteristics such as steroid use, improved the prediction of survival without major morbidity, sex, GA at birth and BW for GA predicted survival without major morbidity almost as accurately (area under the curve: 0.84). The graphical tool based on the models showed how the GA and BW for GA interact, to enable prediction of outcomes especially for small and large for GA infants. This graphical tool provides an improved and easily interpretable method to predict survival without major morbidity for very preterm infants at the time of birth. These curves are especially useful for small and large for GA infants.

  20. Transportable Applications Environment (TAE) Plus: A NASA tool used to develop and manage graphical user interfaces

    NASA Technical Reports Server (NTRS)

    Szczur, Martha R.

    1992-01-01

    The Transportable Applications Environment (TAE) Plus was built to support the construction of graphical user interfaces (GUI's) for highly interactive applications, such as real-time processing systems and scientific analysis systems. It is a general purpose portable tool that includes a 'What You See Is What You Get' WorkBench that allows user interface designers to layout and manipulate windows and interaction objects. The WorkBench includes both user entry objects (e.g., radio buttons, menus) and data-driven objects (e.g., dials, gages, stripcharts), which dynamically change based on values of realtime data. Discussed here is what TAE Plus provides, how the implementation has utilized state-of-the-art technologies within graphic workstations, and how it has been used both within and without NASA.

  1. Preparing Colorful Astronomical Images and Illustrations

    NASA Astrophysics Data System (ADS)

    Levay, Z. G.; Frattare, L. M.

    2001-12-01

    We present techniques for using mainstream graphics software, specifically Adobe Photoshop and Illustrator, for producing composite color images and illustrations from astronomical data. These techniques have been used with numerous images from the Hubble Space Telescope to produce printed and web-based news, education and public presentation products as well as illustrations for technical publication. While Photoshop is not intended for quantitative analysis of full dynamic range data (as are IRAF or IDL, for example), we have had much success applying Photoshop's numerous, versatile tools to work with scaled images, masks, text and graphics in multiple semi-transparent layers and channels. These features, along with its user-oriented, visual interface, provide convenient tools to produce high-quality, full-color images and graphics for printed and on-line publication and presentation.

  2. Data visualization, bar naked: A free tool for creating interactive graphics.

    PubMed

    Weissgerber, Tracey L; Savic, Marko; Winham, Stacey J; Stanisavljevic, Dejana; Garovic, Vesna D; Milic, Natasa M

    2017-12-15

    Although bar graphs are designed for categorical data, they are routinely used to present continuous data in studies that have small sample sizes. This presentation is problematic, as many data distributions can lead to the same bar graph, and the actual data may suggest different conclusions from the summary statistics. To address this problem, many journals have implemented new policies that require authors to show the data distribution. This paper introduces a free, web-based tool for creating an interactive alternative to the bar graph (http://statistika.mfub.bg.ac.rs/interactive-dotplot/). This tool allows authors with no programming expertise to create customized interactive graphics, including univariate scatterplots, box plots, and violin plots, for comparing values of a continuous variable across different study groups. Individual data points may be overlaid on the graphs. Additional features facilitate visualization of subgroups or clusters of non-independent data. A second tool enables authors to create interactive graphics from data obtained with repeated independent experiments (http://statistika.mfub.bg.ac.rs/interactive-repeated-experiments-dotplot/). These tools are designed to encourage exploration and critical evaluation of the data behind the summary statistics and may be valuable for promoting transparency, reproducibility, and open science in basic biomedical research. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. Novel presentational approaches were developed for reporting network meta-analysis.

    PubMed

    Tan, Sze Huey; Cooper, Nicola J; Bujkiewicz, Sylwia; Welton, Nicky J; Caldwell, Deborah M; Sutton, Alexander J

    2014-06-01

    To present graphical tools for reporting network meta-analysis (NMA) results aiming to increase the accessibility, transparency, interpretability, and acceptability of NMA analyses. The key components of NMA results were identified based on recommendations by agencies such as the National Institute for Health and Care Excellence (United Kingdom). Three novel graphs were designed to amalgamate the identified components using familiar graphical tools such as the bar, line, or pie charts and adhering to good graphical design principles. Three key components for presentation of NMA results were identified, namely relative effects and their uncertainty, probability of an intervention being best, and between-study heterogeneity. Two of the three graphs developed present results (for each pairwise comparison of interventions in the network) obtained from both NMA and standard pairwise meta-analysis for easy comparison. They also include options to display the probability best, ranking statistics, heterogeneity, and prediction intervals. The third graph presents rankings of interventions in terms of their effectiveness to enable clinicians to easily identify "top-ranking" interventions. The graphical tools presented can display results tailored to the research question of interest, and targeted at a whole spectrum of users from the technical analyst to the nontechnical clinician. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Body Motion and Graphing.

    ERIC Educational Resources Information Center

    Nemirovsky, Ricardo; Tierney, Cornelia; Wright, Tracy

    1998-01-01

    Analyzed two children's use of a computer-based motion detector to make sense of symbolic expressions (Cartesian graphs). Found three themes: (1) tool perspectives, efforts to understand graphical responses to body motion; (2) fusion, emergent ways of talking and behaving that merge symbols and referents; and (3) graphical spaces, when changing…

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudleson, B.; Arnold, M.; McCann, D.

    Rapid detection of unexpected drilling events requires continuous monitoring of drilling parameters. A major R and D program by a drilling contractor has led to the introduction of a computerized monitoring system on its offshore rigs. System includes advanced color graphics displays and new smart alarms to help both contractor and operator personnel detect and observe drilling events before they would normally be apparent with conventional rig instrumentation. This article describes a module of this monitoring system, which uses expert system technology to detect the earliest stages of drillstring washouts. Field results demonstrate the effectiveness of the smart alarm incorporatedmore » in the system. Early detection allows the driller to react before a twist-off results in expensive fishing operations.« less

  6. Development of a character, line and point display system. [for medical records

    NASA Technical Reports Server (NTRS)

    Owen, E. W.

    1977-01-01

    A compact graphics terminal for use as the input to a computerized medical records system is described. The principal mode of communication between the terminal and the records system is by checklists and menu selection. However, the terminal accepts short, handwritten messages as well as conventional alphanumeric input. The terminal consists of an electronic tablet, a display, a microcomputer controller, a character generator, and a refresh memory for the display. An Intel SBC 80/10 microcomputer controls the flow of information and a 16 kilobyte memory stores the point-by-point array of information to be displayed. A specially designed interface continuously generates the raster display without the intervention of the microcomputer.

  7. Guided medication dosing for elderly emergency patients using real-time, computerized decision support.

    PubMed

    Griffey, Richard T; Lo, Helen G; Burdick, Elisabeth; Keohane, Carol; Bates, David W

    2012-01-01

    To evaluate the impact of a real-time computerized decision support tool in the emergency department that guides medication dosing for the elderly on physician ordering behavior and on adverse drug events (ADEs). A prospective controlled trial was conducted over 26 weeks. The status of the decision support tool alternated OFF (7/17/06-8/29/06), ON (8/29/06-10/10/06), OFF (10/10/06-11/28/06), and ON (11/28/06-1/16/07) in consecutive blocks during the study period. In patients ≥65 who were ordered certain benzodiazepines, opiates, non-steroidals, or sedative-hypnotics, the computer application either adjusted the dosing or suggested a different medication. Physicians could accept or reject recommendations. The primary outcome compared medication ordering consistent with recommendations during ON versus OFF periods. Secondary outcomes included the admission rate, emergency department length of stay for discharged patients, 10-fold dosing orders, use of a second drug to reverse the original medication, and rate of ADEs using previously validated explicit chart review. 2398 orders were placed for 1407 patients over 1548 visits. The majority (49/53; 92.5%) of recommendations for alternate medications were declined. More orders were consistent with dosing recommendations during ON (403/1283; 31.4%) than OFF (256/1115; 23%) periods (p≤0.0001). 673 (43%) visits were reviewed for ADEs. The rate of ADEs was lower during ON (8/237; 3.4%) compared with OFF (31/436; 7.1%) periods (p=0.02). The remaining secondary outcomes showed no difference. Single institution study, retrospective chart review for ADEs. Though overall agreement with recommendations was low, real-time computerized decision support resulted in greater acceptance of medication recommendations. Fewer ADEs were observed when computerized decision support was active.

  8. Engineering graphics data entry for space station data base

    NASA Technical Reports Server (NTRS)

    Lacovara, R. C.

    1986-01-01

    The entry of graphical engineering data into the Space Station Data Base was examined. Discussed were: representation of graphics objects; representation of connectivity data; graphics capture hardware; graphics display hardware; site-wide distribution of graphics, and consolidation of tools and hardware. A fundamental assumption was that existing equipment such as IBM based graphics capture software and VAX networked facilities would be exploited. Defensible conclusions reached after study and simulations of use of these systems at the engineering level are: (1) existing IBM based graphics capture software is an adequate and economical means of entry of schematic and block diagram data for present and anticipated electronic systems for Space Station; (2) connectivity data from the aforementioned system may be incorporated into the envisioned Space Station Data Base with modest effort; (3) graphics and connectivity data captured on the IBM based system may be exported to the VAX network in a simple and direct fashion; (4) graphics data may be displayed site-wide on VT-125 terminals and lookalikes; (5) graphics hard-copy may be produced site-wide on various dot-matrix printers; and (6) the system may provide integrated engineering services at both the engineering and engineering management level.

  9. Anvil Forecast Tool in the Advanced Weather Interactive Processing System

    NASA Technical Reports Server (NTRS)

    Barrett, Joe H., III; Hood, Doris

    2009-01-01

    Meteorologists from the 45th Weather Squadron (45 WS) and National Weather Service Spaceflight Meteorology Group (SMG) have identified anvil forecasting as one of their most challenging tasks when predicting the probability of violations of the Lightning Launch Commit Criteria and Space Shuttle Flight Rules. As a result, the Applied Meteorology Unit (AMU) was tasked to create a graphical overlay tool for the Meteorological Interactive Data Display System (MIDDS) that indicates the threat of thunderstorm anvil clouds, using either observed or model forecast winds as input. The tool creates a graphic depicting the potential location of thunderstorm anvils one, two, and three hours into the future. The locations are based on the average of the upper level observed or forecasted winds. The graphic includes 10 and 20 n mi standoff circles centered at the location of interest, as well as one-, two-, and three-hour arcs in the upwind direction. The arcs extend outward across a 30 sector width based on a previous AMU study that determined thunderstorm anvils move in a direction plus or minus 15 of the upper-level wind direction. The AMU was then tasked to transition the tool to the Advanced Weather Interactive Processing System (AWIPS). SMG later requested the tool be updated to provide more flexibility and quicker access to model data. This presentation describes the work performed by the AMU to transition the tool into AWIPS, as well as the subsequent improvements made to the tool.

  10. ControlShell: A real-time software framework

    NASA Technical Reports Server (NTRS)

    Schneider, Stanley A.; Chen, Vincent W.; Pardo-Castellote, Gerardo

    1994-01-01

    The ControlShell system is a programming environment that enables the development and implementation of complex real-time software. It includes many building tools for complex systems, such as a graphical finite state machine (FSM) tool to provide strategic control. ControlShell has a component-based design, providing interface definitions and mechanisms for building real-time code modules along with providing basic data management. Some of the system-building tools incorporated in ControlShell are a graphical data flow editor, a component data requirement editor, and a state-machine editor. It also includes a distributed data flow package, an execution configuration manager, a matrix package, and an object database and dynamic binding facility. This paper presents an overview of ControlShell's architecture and examines the functions of several of its tools.

  11. Computer-Based Tools for Evaluating Graphical User Interfaces

    NASA Technical Reports Server (NTRS)

    Moore, Loretta A.

    1997-01-01

    The user interface is the component of a software system that connects two very complex system: humans and computers. Each of these two systems impose certain requirements on the final product. The user is the judge of the usability and utility of the system; the computer software and hardware are the tools with which the interface is constructed. Mistakes are sometimes made in designing and developing user interfaces because the designers and developers have limited knowledge about human performance (e.g., problem solving, decision making, planning, and reasoning). Even those trained in user interface design make mistakes because they are unable to address all of the known requirements and constraints on design. Evaluation of the user inter-face is therefore a critical phase of the user interface development process. Evaluation should not be considered the final phase of design; but it should be part of an iterative design cycle with the output of evaluation being feed back into design. The goal of this research was to develop a set of computer-based tools for objectively evaluating graphical user interfaces. The research was organized into three phases. The first phase resulted in the development of an embedded evaluation tool which evaluates the usability of a graphical user interface based on a user's performance. An expert system to assist in the design and evaluation of user interfaces based upon rules and guidelines was developed during the second phase. During the final phase of the research an automatic layout tool to be used in the initial design of graphical inter- faces was developed. The research was coordinated with NASA Marshall Space Flight Center's Mission Operations Laboratory's efforts in developing onboard payload display specifications for the Space Station.

  12. Advanced techniques in reliability model representation and solution

    NASA Technical Reports Server (NTRS)

    Palumbo, Daniel L.; Nicol, David M.

    1992-01-01

    The current tendency of flight control system designs is towards increased integration of applications and increased distribution of computational elements. The reliability analysis of such systems is difficult because subsystem interactions are increasingly interdependent. Researchers at NASA Langley Research Center have been working for several years to extend the capability of Markov modeling techniques to address these problems. This effort has been focused in the areas of increased model abstraction and increased computational capability. The reliability model generator (RMG) is a software tool that uses as input a graphical object-oriented block diagram of the system. RMG uses a failure-effects algorithm to produce the reliability model from the graphical description. The ASSURE software tool is a parallel processing program that uses the semi-Markov unreliability range evaluator (SURE) solution technique and the abstract semi-Markov specification interface to the SURE tool (ASSIST) modeling language. A failure modes-effects simulation is used by ASSURE. These tools were used to analyze a significant portion of a complex flight control system. The successful combination of the power of graphical representation, automated model generation, and parallel computation leads to the conclusion that distributed fault-tolerant system architectures can now be analyzed.

  13. CEQer: a graphical tool for copy number and allelic imbalance detection from whole-exome sequencing data.

    PubMed

    Piazza, Rocco; Magistroni, Vera; Pirola, Alessandra; Redaelli, Sara; Spinelli, Roberta; Redaelli, Serena; Galbiati, Marta; Valletta, Simona; Giudici, Giovanni; Cazzaniga, Giovanni; Gambacorti-Passerini, Carlo

    2013-01-01

    Copy number alterations (CNA) are common events occurring in leukaemias and solid tumors. Comparative Genome Hybridization (CGH) is actually the gold standard technique to analyze CNAs; however, CGH analysis requires dedicated instruments and is able to perform only low resolution Loss of Heterozygosity (LOH) analyses. Here we present CEQer (Comparative Exome Quantification analyzer), a new graphical, event-driven tool for CNA/allelic-imbalance (AI) coupled analysis of exome sequencing data. By using case-control matched exome data, CEQer performs a comparative digital exonic quantification to generate CNA data and couples this information with exome-wide LOH and allelic imbalance detection. This data is used to build mixed statistical/heuristic models allowing the identification of CNA/AI events. To test our tool, we initially used in silico generated data, then we performed whole-exome sequencing from 20 leukemic specimens and corresponding matched controls and we analyzed the results using CEQer. Taken globally, these analyses showed that the combined use of comparative digital exon quantification and LOH/AI allows generating very accurate CNA data. Therefore, we propose CEQer as an efficient, robust and user-friendly graphical tool for the identification of CNA/AI in the context of whole-exome sequencing data.

  14. National Centers for Environmental Prediction

    Science.gov Websites

    Reference List Table of Contents NCEP OPERATIONAL MODEL FORECAST GRAPHICS PARALLEL/EXPERIMENTAL MODEL Developmental Air Quality Forecasts and Verification Back to Table of Contents 2. PARALLEL/EXPERIMENTAL GRAPHICS VERIFICATION (GRID VS.OBS) WEB PAGE (NCEP EXPERIMENTAL PAGE, INTERNAL USE ONLY) Interactive web page tool for

  15. Computer Art--A New Tool in Advertising Graphics.

    ERIC Educational Resources Information Center

    Wassmuth, Birgit L.

    Using computers to produce art began with scientists, mathematicians, and individuals with strong technical backgrounds who used the graphic material as visualizations of data in technical fields. People are using computer art in advertising, as well as in painting; sculpture; music; textile, product, industrial, and interior design; architecture;…

  16. Science Learning with Information Technologies as a Tool for "Scientific Thinking" in Engineering Education

    ERIC Educational Resources Information Center

    Smirnov, Eugeny; Bogun, Vitali

    2011-01-01

    New methodologies in science (or mathematics) learning process and scientific thinking in the classroom activity of engineer students with ICT (information and communication technology), including graphic calculator are presented: visual modelling with ICT, action research with graphic calculator, insight in classroom and communications and…

  17. Colossal Tooling Design: 3D Simulation for Ergonomic Analysis

    NASA Technical Reports Server (NTRS)

    Hunter, Steve L.; Dischinger, Charles; Thomas, Robert E.; Babai, Majid

    2003-01-01

    The application of high-level 3D simulation software to the design phase of colossal mandrel tooling for composite aerospace fuel tanks was accomplished to discover and resolve safety and human engineering problems. The analyses were conducted to determine safety, ergonomic and human engineering aspects of the disassembly process of the fuel tank composite shell mandrel. Three-dimensional graphics high-level software, incorporating various ergonomic analysis algorithms, was utilized to determine if the process was within safety and health boundaries for the workers carrying out these tasks. In addition, the graphical software was extremely helpful in the identification of material handling equipment and devices for the mandrel tooling assembly/disassembly process.

  18. What Shape is Your Resident in? Using a Radar Plot to Guide a Milestone Clinical Competency Discussion.

    PubMed

    Harrington, David T; Miner, Thomas J; Ng, Thomas; Charpentier, Kevin P; Richardson, Pam; Cioffi, William G

    2015-01-01

    One of the challenges for program directors (PDs) is to sort and weight the tidal wave of assessments that training programs create in the modern Milestone era. We evaluated whether the use of a radar plot (RP) would be helpful in sorting data and providing a graphic representation of each resident's progress. Using at least 2 different types of assessments for each of the 16 surgical Milestones, the data were ranked and weighted by a predetermined method embedded in a computerized workbook (Excel). This process created a unique 16-spoked RP for each resident (Fig. below). The RP allowed the faculty to see areas of weakness (shown by concavity) and allowed an overall grade calculated as a ratio of the area of the smooth outer circle (faculty expectations, triangles) and the resident's unique radar shape (resident performance, squares). To help us validate our new tool, we looked at whether residents with recent remedial issues "looked" different from residents without remedial issues. Of our 30 categorical residents, 8 had significant areas of concavities, suggesting possible areas of improvement. Of these 8 residents, 4 had been on a remediation program in the last 18 months. The average ratio of performance/expectations was 0.709. The 4 residents on recent remediation had a ratio of 0.616 when compared with 0.723 for the residents without remedial issues (p < 0.009). Many exciting challenges await PDs, as we evolve to a competency-based evaluation system. The use of an evaluation summary tool using RPs may aid PDs in leading clinical competency discussions and in monitoring a resident's progress over time. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Graphic Pathographies and the Ethical Practice of Person-Centered Medicine.

    PubMed

    Myers, Kimberly R; Goldenberg, Michael D F

    2018-02-01

    Graphic medicine is a swiftly growing movement that explores, theoretically and practically, the use of comics in medical education and patient care. At the heart of graphic medicine are graphic pathographies, stories of illness conveyed in comic form. These stories are helpful tools for health care professionals who seek new insight into the personal, lived experience of illness and for patients who want to learn more about their disease from others who have actually experienced it. Featuring excerpts from five graphic pathographies, this essay illustrates how the medium can be used to educate patients and enhance empathy in health care professionals, particularly with regard to informed consent and end-of-life issues. © 2018 American Medical Association. All Rights Reserved.

  20. Mathematic in science progress reort, June 1, 1973-May 31, 1974

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellman, R.

    1974-01-01

    The purpose of the matematical biosciences group is to use the conceptual, analytic and computational methods of modern mathematics to treat biomedical and environmental problems. We are employing a systems approach to research, beginning with experiment and medical practice at one end of the scale, continuing through the intermediary of mathematical models and computer techniques, and culminating in clinical applications working closely with teams of doctors. We are pursuing the application of biostatistical methods to a number of medical questions as well as a thoroughgoing use of operations research and systems analysis to hospital practice. The overall objective is tomore » make the Medicare program operational, effective as well as cheap. Pattern recognition and other aspects of artificial intelligence are important here for patient screening. Major efforts are devoted to nuclear medicine, radiotherapy and neurophysiology using the mathematical theory of control and decision processes (dynamic programming and invarient imbedding). Important savings have been made in the time required for tumor scanning using techniques of nuclear medicine. Major mathematical breakthroughs have been made in the treatment of large scale systems, and parameter identification processes. In the field of mental health, we have developed and extended the computerized simulation processes using graphics which are versatile tools for research and training in human interaction processes, particularly in the initial psychotherapy interview.« less

  1. Reduction in patient burdens with graphical computerized adaptive testing on the ADL scale: tool development and simulation.

    PubMed

    Chien, Tsair-Wei; Wu, Hing-Man; Wang, Weng-Chung; Castillo, Roberto Vasquez; Chou, Willy

    2009-05-05

    The aim of this study was to verify the effectiveness and efficacy of saving time and reducing burden for patients, nurses, and even occupational therapists through computer adaptive testing (CAT). Based on an item bank of the Barthel Index (BI) and the Frenchay Activities Index (FAI) for assessing comprehensive activities of daily living (ADL) function in stroke patients, we developed a visual basic application (VBA)-Excel CAT module, and (1) investigated whether the averaged test length via CAT is shorter than that of the traditional all-item-answered non-adaptive testing (NAT) approach through simulation, (2) illustrated the CAT multimedia on a tablet PC showing data collection and response errors of ADL clinical functional measures in stroke patients, and (3) demonstrated the quality control of endorsing scale with fit statistics to detect responding errors, which will be further immediately reconfirmed by technicians once patient ends the CAT assessment. The results show that endorsed items could be shorter on CAT (M = 13.42) than on NAT (M = 23) at 41.64% efficiency in test length. However, averaged ability estimations reveal insignificant differences between CAT and NAT. This study found that mobile nursing services, placed at the bedsides of patients could, through the programmed VBA-Excel CAT module, reduce the burden to patients and save time, more so than the traditional NAT paper-and-pencil testing appraisals.

  2. Technology for the product and process data base

    NASA Technical Reports Server (NTRS)

    Barnes, R. D.

    1984-01-01

    The computerized product and process data base is increasingly recognized to be the cornerstone component of an overall system aimed at the integrated automation of the industrial processes of a given company or enterprise. The technology needed to support these more effective computer integrated design and manufacturing methods, especially the concept of 3-D computer-sensible product definitions rather than engineering drawings, is not fully available and rationalized. Progress is being made, however, in bridging this technology gap with concentration on the modeling of sophisticated information and data structures, high-performance interactive user interfaces and comprehensive tools for managing the resulting computerized product definition and process data base.

  3. Using three-dimensional-computerized tomography as a diagnostic tool for temporo-mandibular joint ankylosis: a case report.

    PubMed

    Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C

    1999-04-01

    Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.

  4. WASP: a Web-based Allele-Specific PCR assay designing tool for detecting SNPs and mutations

    PubMed Central

    Wangkumhang, Pongsakorn; Chaichoompu, Kridsadakorn; Ngamphiw, Chumpol; Ruangrit, Uttapong; Chanprasert, Juntima; Assawamakin, Anunchai; Tongsima, Sissades

    2007-01-01

    Background Allele-specific (AS) Polymerase Chain Reaction is a convenient and inexpensive method for genotyping Single Nucleotide Polymorphisms (SNPs) and mutations. It is applied in many recent studies including population genetics, molecular genetics and pharmacogenomics. Using known AS primer design tools to create primers leads to cumbersome process to inexperience users since information about SNP/mutation must be acquired from public databases prior to the design. Furthermore, most of these tools do not offer the mismatch enhancement to designed primers. The available web applications do not provide user-friendly graphical input interface and intuitive visualization of their primer results. Results This work presents a web-based AS primer design application called WASP. This tool can efficiently design AS primers for human SNPs as well as mutations. To assist scientists with collecting necessary information about target polymorphisms, this tool provides a local SNP database containing over 10 million SNPs of various populations from public domain databases, namely NCBI dbSNP, HapMap and JSNP respectively. This database is tightly integrated with the tool so that users can perform the design for existing SNPs without going off the site. To guarantee specificity of AS primers, the proposed system incorporates a primer specificity enhancement technique widely used in experiment protocol. In particular, WASP makes use of different destabilizing effects by introducing one deliberate 'mismatch' at the penultimate (second to last of the 3'-end) base of AS primers to improve the resulting AS primers. Furthermore, WASP offers graphical user interface through scalable vector graphic (SVG) draw that allow users to select SNPs and graphically visualize designed primers and their conditions. Conclusion WASP offers a tool for designing AS primers for both SNPs and mutations. By integrating the database for known SNPs (using gene ID or rs number), this tool facilitates the awkward process of getting flanking sequences and other related information from public SNP databases. It takes into account the underlying destabilizing effect to ensure the effectiveness of designed primers. With user-friendly SVG interface, WASP intuitively presents resulting designed primers, which assist users to export or to make further adjustment to the design. This software can be freely accessed at . PMID:17697334

  5. Feasibility and acceptability of a computer-based tool to improve contraceptive counseling.

    PubMed

    Wilson, Ellen K; Krieger, Kathleen E; Koo, Helen P; Minnis, Alexandra M; Treiman, Katherine

    2014-07-01

    The objective was to test the feasibility and acceptability of a computerized tool, Smart Choices, designed to enhance the quality of contraceptive counseling in family planning clinics. The tool includes (a) a questionnaire completed by patients and summarized in a printout for providers and (b) a birth control guide patients explore to learn about various contraceptive methods. In 2 family planning clinics, we conducted interviews with 125 women who used the Smart Choices computerized tool and 7 providers. Smart Choices integrated into clinic flow well in one clinic, but less well in the other, which had very short waiting times. Patients were generally enthusiastic about Smart Choices, including its helpfulness in preparing them and their providers for the counseling session and increasing their knowledge of contraceptive methods. Providers varied in how much they used the printout and in their opinions about its usefulness. Some felt its usefulness was limited because it overlapped with the clinic's intake forms or because it did not match with their concept of counseling needs. Others felt it provided valuable information not collected by intake forms and more honest information. Some found Smart Choices to be most helpful with patients who were unsure what method they wanted. Smart Choices is feasible to implement and well received by patients, but modifications are needed to increase provider enthusiasm for this tool. The Smart Choices tool requires refinement before widespread dissemination. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Flight Telerobotic Servicer prototype simulator

    NASA Astrophysics Data System (ADS)

    Schein, Rob; Krauze, Linda; Hartley, Craig; Dickenson, Alan; Lavecchia, Tom; Working, Bob

    A prototype simulator for the Flight Telerobotic Servicer (FTS) system is described for use in the design development of the FTS, emphasizing the hand controller and user interface. The simulator utilizes a graphics workstation based on rapid prototyping tools for systems analyses of the use of the user interface and the hand controller. Kinematic modeling, manipulator-control algorithms, and communications programs are contained in the software for the simulator. The hardwired FTS panels and operator interface for use on the STS Orbiter are represented graphically, and the simulated controls function as the final FTS system configuration does. The robotic arm moves based on the user hand-controller interface, and the joint angles and other data are given on the prototype of the user interface. This graphics simulation tool provides the means for familiarizing crewmembers with the FTS system operation, displays, and controls.

  7. CONFIG: Qualitative simulation tool for analyzing behavior of engineering devices

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.; Basham, Bryan D.; Harris, Richard A.

    1987-01-01

    To design failure management expert systems, engineers mentally analyze the effects of failures and procedures as they propagate through device configurations. CONFIG is a generic device modeling tool for use in discrete event simulation, to support such analyses. CONFIG permits graphical modeling of device configurations and qualitative specification of local operating modes of device components. Computation requirements are reduced by focussing the level of component description on operating modes and failure modes, and specifying qualitative ranges of variables relative to mode transition boundaries. Simulation processing occurs only when modes change or variables cross qualitative boundaries. Device models are built graphically, using components from libraries. Components are connected at ports by graphical relations that define data flow. The core of a component model is its state transition diagram, which specifies modes of operation and transitions among them.

  8. Computerized Assessment of Competence-Related Abilities in Living Liver Donors: The Adult-to-Adult Living Donor Liver Transplantation Cohort Study (A2ALL)

    PubMed Central

    Freeman, Jason; Emond, Jean; Gillespie, Brenda W.; Appelbaum, Paul S.; Weinrieb, Robert; Hill-Callahan, Peg; Gordon, Elisa J.; Terrault, Norah; Trotter, James; Ashworth, April; Dew, Mary Amanda; Pruett, Timothy

    2014-01-01

    Background Despite its importance, determination of competence to consent to organ donation varies widely based on local standards. We piloted a new tool to aid transplant centers in donor assessment. Methods We assessed competence-related abilities among potential living liver donors (LDs) in the 9-center A2ALL study. Prospective LDs viewed an educational video, and were queried to assess Understanding, Appreciation, Reasoning, and ability to express a Final Choice using the MacArthur Competence Assessment Tool for Clinical Research, adapted for computerized administration in LDs (“MacLiver”). Videotaped responses were scored by a clinical neuropsychologist (JF). Results Ninety-three LDs were assessed. Mean (standard deviation; domain maximum) scores were: Understanding: 18.1 (2.6; max=22), Appreciation: 5.1 (1.0; max=6), Reasoning: 3.1 (0.8; max=4), and Final Choice: 3.8 (0.5; max=4). Scores did not differ by demographics, relationship to the recipient, eligibility to donate, or eventual donation (p>0.4). Higher education was associated with greater Understanding (p=0.004) and Reasoning (p=0.03). Conclusion Standardized, computerized education with independent ratings of responses may (1) alert the clinical staff to potential donors who may not be competent to donate, and (2) highlight areas needing further assessment and education, leading to better informed decision-making. PMID:23859354

  9. High-Tech Roof Management.

    ERIC Educational Resources Information Center

    Benzie, Tim

    1997-01-01

    Describes the use of a computerized roof management system (CRMS) for school districts to foster multiple roof maintenance efficiency and cost effectiveness. Highlights CRMS software manufacturer choices, as well as the types of nondestructive testing equipment tools that can be used to evaluate roof conditions. (GR)

  10. Growth and yield models for central hardwoods

    Treesearch

    Martin E. Dale; Donald E. Hilt

    1989-01-01

    Over the last 20 years computers have become an efficient tool to estimate growth and yield. Computerized yield estimates vary from simple approximation or interpolation of traditional normal yield tables to highly sophisticated programs that simulate the growth and yield of each individual tree.

  11. A Computer-Aided Abstracting Tool Kit.

    ERIC Educational Resources Information Center

    Craven, Timothy C.

    1993-01-01

    Reports on the development of a prototype computerized abstractor's assistant called TEXNET, a text network management system. Features of the system discussed include semantic dependency links; displays of text structure; basic text editing; extracting; weighting methods; and listings of frequent words. (Contains 25 references.) (LRW)

  12. Reliability, validity and sensitivity of a computerized visual analog scale measuring state anxiety.

    PubMed

    Abend, Rany; Dan, Orrie; Maoz, Keren; Raz, Sivan; Bar-Haim, Yair

    2014-12-01

    Assessment of state anxiety is frequently required in clinical and research settings, but its measurement using standard multi-item inventories entails practical challenges. Such inventories are increasingly complemented by paper-and-pencil, single-item visual analog scales measuring state anxiety (VAS-A), which allow rapid assessment of current anxiety states. Computerized versions of VAS-A offer additional advantages, including facilitated and accurate data collection and analysis, and applicability to computer-based protocols. Here, we establish the psychometric properties of a computerized VAS-A. Experiment 1 assessed the reliability, convergent validity, and discriminant validity of the computerized VAS-A in a non-selected sample. Experiment 2 assessed its sensitivity to increase in state anxiety following social stress induction, in participants with high levels of social anxiety. Experiment 1 demonstrated the computerized VAS-A's test-retest reliability (r = .44, p < .001); convergent validity with the State-Trait Anxiety Inventory's state subscale (STAI-State; r = .60, p < .001); and discriminant validity as indicated by significantly lower correlations between VAS-A and different psychological measures relative to the correlation between VAS-A and STAI-State. Experiment 2 demonstrated the VAS-A's sensitivity to changes in state anxiety via a significant pre- to during-stressor rise in VAS-A scores (F(1,48) = 25.13, p < .001). Set-order administration of measures, absence of clinically-anxious population, and gender-unbalanced samples. The adequate psychometric characteristics, combined with simple and rapid administration, make the computerized VAS-A a valuable self-rating tool for state anxiety. It may prove particularly useful for clinical and research settings where multi-item inventories are less applicable, including computer-based treatment and assessment protocols. The VAS-A is freely available: http://people.socsci.tau.ac.il/mu/anxietytrauma/visual-analog-scale/. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Visual ModuleOrganizer: a graphical interface for the detection and comparative analysis of repeat DNA modules

    PubMed Central

    2014-01-01

    Background DNA repeats, such as transposable elements, minisatellites and palindromic sequences, are abundant in sequences and have been shown to have significant and functional roles in the evolution of the host genomes. In a previous study, we introduced the concept of a repeat DNA module, a flexible motif present in at least two occurences in the sequences. This concept was embedded into ModuleOrganizer, a tool allowing the detection of repeat modules in a set of sequences. However, its implementation remains difficult for larger sequences. Results Here we present Visual ModuleOrganizer, a Java graphical interface that enables a new and optimized version of the ModuleOrganizer tool. To implement this version, it was recoded in C++ with compressed suffix tree data structures. This leads to less memory usage (at least 120-fold decrease in average) and decreases by at least four the computation time during the module detection process in large sequences. Visual ModuleOrganizer interface allows users to easily choose ModuleOrganizer parameters and to graphically display the results. Moreover, Visual ModuleOrganizer dynamically handles graphical results through four main parameters: gene annotations, overlapping modules with known annotations, location of the module in a minimal number of sequences, and the minimal length of the modules. As a case study, the analysis of FoldBack4 sequences clearly demonstrated that our tools can be extended to comparative and evolutionary analyses of any repeat sequence elements in a set of genomic sequences. With the increasing number of sequences available in public databases, it is now possible to perform comparative analyses of repeated DNA modules in a graphic and friendly manner within a reasonable time period. Availability Visual ModuleOrganizer interface and the new version of the ModuleOrganizer tool are freely available at: http://lcb.cnrs-mrs.fr/spip.php?rubrique313. PMID:24678954

  14. Circumventing Graphical User Interfaces in Chemical Engineering Plant Design

    ERIC Educational Resources Information Center

    Romey, Noel; Schwartz, Rachel M.; Behrend, Douglas; Miao, Peter; Cheung, H. Michael; Beitle, Robert

    2007-01-01

    Graphical User Interfaces (GUIs) are pervasive elements of most modern technical software and represent a convenient tool for student instruction. For example, GUIs are used for [chemical] process design software (e.g., CHEMCAD, PRO/II and ASPEN) typically encountered in the senior capstone course. Drag and drop aspects of GUIs are challenging for…

  15. Chemical Engineering and Instructional Computing: Are They in Step? (Part 2).

    ERIC Educational Resources Information Center

    Seider, Warren D.

    1988-01-01

    Describes the use of "CACHE IBM PC Lessons for Courses Other than Design and Control" as open-ended design oriented problems. Presents graphics from some of the software and discusses high-resolution graphics workstations. Concludes that computing tools are in line with design and control practice in chemical engineering. (MVL)

  16. An interactive interface for NCAR Graphics

    NASA Technical Reports Server (NTRS)

    Buzbee, Bill; Lackman, Bob; Alpert, Ethan

    1994-01-01

    The NCAR Graphics package has been a valuable research tool for over 20 years. As a low level Fortran library, however, it was difficult to use for nonprogramming researchers. With this grant and NSF support, an interactive interface has been created which greatly facilitates use of the package by researchers of diverse computer skill levels.

  17. Hear My Voice! Teaching Difficult Subjects with Graphic Organizers

    ERIC Educational Resources Information Center

    Barbieri, Kim E.

    2011-01-01

    Graphic organizers are immensely popular--and much utilized--in many classrooms, particularly at the elementary level. These creative and innovate teaching tools are a very effective addition to the teaching repertoire and may be designed to maximize precious class time. For the secondary social studies teacher, their instant appeal and universal…

  18. A graphical user interface for RAId, a knowledge integrated proteomics analysis suite with accurate statistics.

    PubMed

    Joyce, Brendan; Lee, Danny; Rubio, Alex; Ogurtsov, Aleksey; Alves, Gelio; Yu, Yi-Kuo

    2018-03-15

    RAId is a software package that has been actively developed for the past 10 years for computationally and visually analyzing MS/MS data. Founded on rigorous statistical methods, RAId's core program computes accurate E-values for peptides and proteins identified during database searches. Making this robust tool readily accessible for the proteomics community by developing a graphical user interface (GUI) is our main goal here. We have constructed a graphical user interface to facilitate the use of RAId on users' local machines. Written in Java, RAId_GUI not only makes easy executions of RAId but also provides tools for data/spectra visualization, MS-product analysis, molecular isotopic distribution analysis, and graphing the retrieval versus the proportion of false discoveries. The results viewer displays and allows the users to download the analyses results. Both the knowledge-integrated organismal databases and the code package (containing source code, the graphical user interface, and a user manual) are available for download at https://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads/raid.html .

  19. Methodology to assess clinical liver safety data.

    PubMed

    Merz, Michael; Lee, Kwan R; Kullak-Ublick, Gerd A; Brueckner, Andreas; Watkins, Paul B

    2014-11-01

    Analysis of liver safety data has to be multivariate by nature and needs to take into account time dependency of observations. Current standard tools for liver safety assessment such as summary tables, individual data listings, and narratives address these requirements to a limited extent only. Using graphics in the context of a systematic workflow including predefined graph templates is a valuable addition to standard instruments, helping to ensure completeness of evaluation, and supporting both hypothesis generation and testing. Employing graphical workflows interactively allows analysis in a team-based setting and facilitates identification of the most suitable graphics for publishing and regulatory reporting. Another important tool is statistical outlier detection, accounting for the fact that for assessment of Drug-Induced Liver Injury, identification and thorough evaluation of extreme values has much more relevance than measures of central tendency in the data. Taken together, systematical graphical data exploration and statistical outlier detection may have the potential to significantly improve assessment and interpretation of clinical liver safety data. A workshop was convened to discuss best practices for the assessment of drug-induced liver injury (DILI) in clinical trials.

  20. Computerized visual feedback: an adjunct to robotic-assisted gait training.

    PubMed

    Banz, Raphael; Bolliger, Marc; Colombo, Gery; Dietz, Volker; Lünenburger, Lars

    2008-10-01

    Robotic devices for walking rehabilitation allow new possibilities for providing performance-related information to patients during gait training. Based on motor learning principles, augmented feedback during robotic-assisted gait training might improve the rehabilitation process used to regain walking function. This report presents a method to provide visual feedback implemented in a driven gait orthosis (DGO). The purpose of the study was to compare the immediate effect on motor output in subjects during robotic-assisted gait training when they used computerized visual feedback and when they followed verbal instructions of a physical therapist. Twelve people with neurological gait disorders due to incomplete spinal cord injury participated. Subjects were instructed to walk within the DGO in 2 different conditions. They were asked to increase their motor output by following the instructions of a therapist and by observing visual feedback. In addition, the subjects' opinions about using visual feedback were investigated by a questionnaire. Computerized visual feedback and verbal instructions by the therapist were observed to result in a similar change in motor output in subjects when walking within the DGO. Subjects reported that they were more motivated and concentrated on their movements when using computerized visual feedback compared with when no form of feedback was provided. Computerized visual feedback is a valuable adjunct to robotic-assisted gait training. It represents a relevant tool to increase patients' motor output, involvement, and motivation during gait training, similar to verbal instructions by a therapist.

  1. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    NASA Technical Reports Server (NTRS)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  2. A Java-Enabled Interactive Graphical Gas Turbine Propulsion System Simulator

    NASA Technical Reports Server (NTRS)

    Reed, John A.; Afjeh, Abdollah A.

    1997-01-01

    This paper describes a gas turbine simulation system which utilizes the newly developed Java language environment software system. The system provides an interactive graphical environment which allows the quick and efficient construction and analysis of arbitrary gas turbine propulsion systems. The simulation system couples a graphical user interface, developed using the Java Abstract Window Toolkit, and a transient, space- averaged, aero-thermodynamic gas turbine analysis method, both entirely coded in the Java language. The combined package provides analytical, graphical and data management tools which allow the user to construct and control engine simulations by manipulating graphical objects on the computer display screen. Distributed simulations, including parallel processing and distributed database access across the Internet and World-Wide Web (WWW), are made possible through services provided by the Java environment.

  3. The pits and falls of graphical presentation

    PubMed Central

    Sperandei, Sandro

    2014-01-01

    Graphics are powerful tools to communicate research results and to gain information from data. However, researchers should be careful when deciding which data to plot and the type of graphic to use, as well as other details. The consequence of bad decisions in these features varies from making research results unclear to distortions of these results, through the creation of “chartjunk” with useless information. This paper is not another tutorial about “good graphics” and “bad graphics”. Instead, it presents guidelines for graphic presentation of research results and some uncommon, but useful examples to communicate basic and complex data types, especially multivariate model results, which are commonly presented only by tables. By the end, there are no answers here, just ideas meant to inspire others on how to create their own graphics. PMID:25351349

  4. Graphical workstation capability for reliability modeling

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Koppen, Sandra V.; Haley, Pamela J.

    1992-01-01

    In addition to computational capabilities, software tools for estimating the reliability of fault-tolerant digital computer systems must also provide a means of interfacing with the user. Described here is the new graphical interface capability of the hybrid automated reliability predictor (HARP), a software package that implements advanced reliability modeling techniques. The graphics oriented (GO) module provides the user with a graphical language for modeling system failure modes through the selection of various fault-tree gates, including sequence-dependency gates, or by a Markov chain. By using this graphical input language, a fault tree becomes a convenient notation for describing a system. In accounting for any sequence dependencies, HARP converts the fault-tree notation to a complex stochastic process that is reduced to a Markov chain, which it can then solve for system reliability. The graphics capability is available for use on an IBM-compatible PC, a Sun, and a VAX workstation. The GO module is written in the C programming language and uses the graphical kernal system (GKS) standard for graphics implementation. The PC, VAX, and Sun versions of the HARP GO module are currently in beta-testing stages.

  5. Utilization of teledentistry as a tool to screen for dental caries among 12-year-old school children in a rural region of India.

    PubMed

    Purohit, Bharathi M; Singh, Abhinav; Dwivedi, Ashish

    2017-03-01

    The study aims to assess the reliability of video-graphic method as a tool to screen the dental caries among 12-year-old school children in a rural region of India. A total of 139 school children participated in the study. Visual tactile examinations were conducted using the Decayed, Missing, and Filled Teeth (DMFT) index. Simultaneously, standardized video recording of the oral cavity was performed. Sensitivity and specificity values were calculated for video-graphic assessment of dental caries. Bland-Altman plot was used to assess agreement between the two methods of caries assessment. Likelihood ratio (LR) and receiver-operating characteristic (ROC) curve were used to assess the predictive accuracy of the video-graphic method. Mean DMFT for the study population was 2.47 ± 2.01 and 2.46 ± 1.91 by visual tactile and video-graphic assessment (P = 0.76; > 0.05). Sensitivity and specificity values of 0.86 and 0.58 were established for video-graphic assessment. A fair degree of agreement was noted between the two methods with Intraclass correlation coefficient (ICC) value of 0.56. LR for video-graphic assessment was 2.05. Bland-Altman plot confirmed the level of agreement between the two assessment methods. The area under curve was 0.69 (CI 0.57, 0.80, P = 0.001). Teledentistry examination is comparable to clinical examination when screening for dental caries among school children. This study provides evidence that teledentistry may be used as an alternative screening tool for assessment of dental caries and is viable for remote consultation and treatment planning. Teledentistry offers to change the dynamics of dental care delivery and may effectively bridge the rural-urban oral health divide. © 2016 American Association of Public Health Dentistry.

  6. NASA Access Mechanism - Graphical user interface information retrieval system

    NASA Technical Reports Server (NTRS)

    Hunter, Judy F.; Generous, Curtis; Duncan, Denise

    1993-01-01

    Access to online information sources of aerospace, scientific, and engineering data, a mission focus for NASA's Scientific and Technical Information Program, has always been limited by factors such as telecommunications, query language syntax, lack of standardization in the information, and the lack of adequate tools to assist in searching. Today, the NASA STI Program's NASA Access Mechanism (NAM) prototype offers a solution to these problems by providing the user with a set of tools that provide a graphical interface to remote, heterogeneous, and distributed information in a manner adaptable to both casual and expert users. Additionally, the NAM provides access to many Internet-based services such as Electronic Mail, the Wide Area Information Servers system, Peer Locating tools, and electronic bulletin boards.

  7. NASA access mechanism: Graphical user interface information retrieval system

    NASA Technical Reports Server (NTRS)

    Hunter, Judy; Generous, Curtis; Duncan, Denise

    1993-01-01

    Access to online information sources of aerospace, scientific, and engineering data, a mission focus for NASA's Scientific and Technical Information Program, has always been limited to factors such as telecommunications, query language syntax, lack of standardization in the information, and the lack of adequate tools to assist in searching. Today, the NASA STI Program's NASA Access Mechanism (NAM) prototype offers a solution to these problems by providing the user with a set of tools that provide a graphical interface to remote, heterogeneous, and distributed information in a manner adaptable to both casual and expert users. Additionally, the NAM provides access to many Internet-based services such as Electronic Mail, the Wide Area Information Servers system, Peer Locating tools, and electronic bulletin boards.

  8. Transportable Applications Environment (TAE) Plus - A NASA productivity tool used to develop graphical user interfaces

    NASA Technical Reports Server (NTRS)

    Szczur, Martha R.

    1991-01-01

    The Transportable Applications Environment (TAE) Plus, developed at NASA's Goddard Space Flight Center, is an advanced portable user interface development environment which simplifies the process of creating and managing complex application graphical user interfaces (GUIs), supports prototyping, allows applications to be oported easily between different platforms, and encourages appropriate levels of user interface consistency between applications. This paper discusses the capabilities of the TAE Plus tool, and how it makes the job of designing and developing GUIs easier for the application developers. The paper also explains how tools like TAE Plus provide for reusability and ensure reliability of UI software components, as well as how they aid in the reduction of development and maintenance costs.

  9. Optimizing the patient transport function at Mayo Clinic.

    PubMed

    Kuchera, Dustin; Rohleder, Thomas R

    2011-01-01

    In this article, we report on the implementation of a computerized scheduling tool to optimize staffing for patient transport at the Mayo Clinic. The tool was developed and implemented in Microsoft Excel and Visual Basic for Applications and includes an easy-to-use interface. The tool allows transport management to consider the trade-offs between patient waiting time and staffing levels. While improved staffing efficiency was a desire of the project, it was important that patient service quality was also maintained. The results show that staffing could be reduced while maintaining historical patient service levels.

  10. Increasing marketability and profitability of product line thru PATRAN and NASTRAN

    NASA Technical Reports Server (NTRS)

    Hyatt, Art

    1989-01-01

    Starting with the design objective the operational cycle life of the Swaging Tool was increased. To accomplish this increase in cycle life without increasing the size or weight of the tool would be engineering achievement. However, not only was the operational cycle life increased between 2 to 10 times but simultaneously the size and weight of the Swage Tool was decreased by about 50 percent. This accomplishment now becomes an outstanding engineering achievement. This achievement was only possible because of the computerized Patran, Nastran and Medusa programs.

  11. A Computerized English-Spanish Correlation Index to Five Biomedical Library Classification Schemes Based on MeSH*

    PubMed Central

    Muench, Eugene V.

    1971-01-01

    A computerized English/Spanish correlation index to five biomedical library classification schemes and a computerized English/Spanish, Spanish/English listings of MeSH are described. The index was accomplished by supplying appropriate classification numbers of five classification schemes (National Library of Medicine; Library of Congress; Dewey Decimal; Cunningham; Boston Medical) to MeSH and a Spanish translation of MeSH The data were keypunched, merged on magnetic tape, and sorted in a computer alphabetically by English and Spanish subject headings and sequentially by classification number. Some benefits and uses of the index are: a complete index to classification schemes based on MeSH terms; a tool for conversion of classification numbers when reclassifying collections; a Spanish index and a crude Spanish translation of five classification schemes; a data base for future applications, e.g., automatic classification. Other classification schemes, such as the UDC, and translations of MeSH into other languages can be added. PMID:5172471

  12. Accounting Information Systems in Healthcare: A Review of the Literature.

    PubMed

    Hammour, Hadal; Househ, Mowafa; Razzak, Hira Abdul

    2017-01-01

    As information technology progresses in Saudi Arabia, the manual accounting systems have become graduallyinadequate for decision needs. Subsequently, private and public healthcare divisions in Saudi Arabia perceive Computerized accounting information system (CAIS) as a vehicle to safeguard efficient and effective flow of information during the analysis, processes, and recording of financial data. Efficient and effective flow of information improvesthe decision making of staff, thereby improving the capability of health care sectors to reduce cost of the medical services.In this paper, we define computerized accounting systems from the point of view of health informatics. Also, the challenges and benefits of supporting CAIS applications in hospitals of Saudi Arabia. With these elements, we conclude that CAIS in Saudi Arabia can serve as a valuable tool for evaluating and controlling the cost of medical services in healthcare sectors. Supplementary education on the significance of having systems of computerized accounting within hospitals for nurses, doctors, and accountants with other health care staff is warranted in future.

  13. Rhymes around the World.

    ERIC Educational Resources Information Center

    Novelli, Joan

    1993-01-01

    Examines how one teacher combined jump rope jingles and computerized telecommunications to create a cross-cultural curriculum, having students use electronic mail to collect data from and play games with other students nationwide. The article also describes technology tools to link students with an international community of learners. (SM)

  14. Presentation of Repeated Phrases in a Computer-Assisted Abstracting Tool Kit.

    ERIC Educational Resources Information Center

    Craven, Timothy C.

    2001-01-01

    Discusses automatic indexing methods and describes the development of a prototype computerized abstractor's assistant. Highlights include the text network management system, TEXNET; phrase selection that follows indexing; phrase display, including Boolean capabilities; results of preliminary testing; and availability of TEXNET software. (LRW)

  15. Technology in HRD.

    ERIC Educational Resources Information Center

    1998

    This document contains four papers from a symposium on technology in human resource development (HRD). "COBRA, an Electronic Performance Support System for the Analysis of Jobs and Tasks" (Theo J. Bastiaens) is described as an integrated computerized environment that provides tools, information, advice, and training to help employees do…

  16. Computerized Manufacturing Automation. Employment, Education, and the Workplace. Summary.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Office of Technology Assessment.

    The application of programmable automation (PA) offers new opportunities to enhance and streamline manufacturing processes. Five PA technologies are examined in this report: computer-aided design, robots, numerically controlled machine tools, flexible manufacturing systems, and computer-integrated manufacturing. Each technology is in a relatively…

  17. COMPUTERIZED NEEDS-ORIENTED QUALITY MEASUREMENT EVALUATION SYSTEM (CONQUEST)

    EPA Science Inventory

    CONQUEST is an easy-to-use quality improvement software tool that uses a common structure and language to help users identity, understand, compare, evaluate, and select among 1,200 clinical performance measures that can be used to assess and improve quality of care. CONQUEST's in...

  18. BanTeC: a software tool for management of corneal transplantation.

    PubMed

    López-Alvarez, P; Caballero, F; Trias, J; Cortés, U; López-Navidad, A

    2005-11-01

    Until recently, all cornea information at our tissue bank was managed manually, no specific database or computer tool had been implemented to provide electronic versions of documents and medical reports. The main objective of the BanTeC project was therefore to create a computerized system to integrate and classify all the information and documents used in the center in order to facilitate management of retrieved, transplanted corneal tissues. We used the Windows platform to develop the project. Microsoft Access and Microsoft Jet Engine were used at the database level and Data Access Objects was the chosen data access technology. In short, the BanTeC software seeks to computerize the tissue bank. All the initial stages of the development have now been completed, from specification of needs, program design and implementation of the software components, to the total integration of the final result in the real production environment. BanTeC will allow the generation of statistical reports for analysis to improve our performance.

  19. Medication supply chain management through implementation of a hospital pharmacy computerized inventory program in Haiti.

    PubMed

    Holm, Michelle R; Rudis, Maria I; Wilson, John W

    2015-01-01

    In the aftermath of the 2010 earthquake in Haiti, St. Luke Hospital was built to help manage the mass casualties and subsequent cholera epidemic. A major problem faced by the hospital system was the lack of an available and sustainable supply of medications. Long-term viability of the hospital system depended largely on developing an uninterrupted medication supply chain. We hypothesized that the implementation of a new Pharmacy Computerized Inventory Program (PCIP) would optimize medication availability and decrease medication shortages. We conducted the research by examining how medications were being utilized and distributed before and after the implementation of PCIP. We measured the number of documented medication transactions in both Phase 1 and Phase 2 as well as user logins to determine if a computerized inventory system would be beneficial in providing a sustainable, long-term solution to their medication management needs. The PCIP incorporated drug ordering, filling the drug requests, distribution, and dispensing of the medications in multiple settings; inventory of currently shelved medications; and graphic reporting of 'real-time' medication usage. During the PCIP initiation and establishment periods, the number of medication transactions increased from 219.6 to 359.5 (p=0.055), respectively, and the mean logins per day increased from 24.3 to 31.5, p<0.0001, respectively. The PCIP allows the hospital staff to identify and order medications with a critically low supply as well as track usage for future medication needs. The pharmacy and nursing staff found the PCIP to be efficient and a significant improvement in their medication utilization. An efficient, customizable, and cost-sensitive PCIP can improve drug inventory management in a simplified and sustainable manner within a resource-constrained hospital.

  20. Medication supply chain management through implementation of a hospital pharmacy computerized inventory program in Haiti

    PubMed Central

    Holm, Michelle R.; Rudis, Maria I.; Wilson, John W.

    2015-01-01

    Background In the aftermath of the 2010 earthquake in Haiti, St. Luke Hospital was built to help manage the mass casualties and subsequent cholera epidemic. A major problem faced by the hospital system was the lack of an available and sustainable supply of medications. Long-term viability of the hospital system depended largely on developing an uninterrupted medication supply chain. Objective We hypothesized that the implementation of a new Pharmacy Computerized Inventory Program (PCIP) would optimize medication availability and decrease medication shortages. Design We conducted the research by examining how medications were being utilized and distributed before and after the implementation of PCIP. We measured the number of documented medication transactions in both Phase 1 and Phase 2 as well as user logins to determine if a computerized inventory system would be beneficial in providing a sustainable, long-term solution to their medication management needs. Results The PCIP incorporated drug ordering, filling the drug requests, distribution, and dispensing of the medications in multiple settings; inventory of currently shelved medications; and graphic reporting of ‘real-time’ medication usage. During the PCIP initiation and establishment periods, the number of medication transactions increased from 219.6 to 359.5 (p=0.055), respectively, and the mean logins per day increased from 24.3 to 31.5, p<0.0001, respectively. The PCIP allows the hospital staff to identify and order medications with a critically low supply as well as track usage for future medication needs. The pharmacy and nursing staff found the PCIP to be efficient and a significant improvement in their medication utilization. Conclusions An efficient, customizable, and cost-sensitive PCIP can improve drug inventory management in a simplified and sustainable manner within a resource-constrained hospital. PMID:25623613

  1. Interactive Graphics Tools for Analysis of MOLA and Other Data

    NASA Technical Reports Server (NTRS)

    Frey, H.; Roark, J.; Sakimoto, S.

    2000-01-01

    We have developed several interactive analysis tools based on the IDL programming language for the analysis of Mars Orbiting Laser Altimeter (MOLA) profile and gridded data which are available to the general community.

  2. 3D data processing with advanced computer graphics tools

    NASA Astrophysics Data System (ADS)

    Zhang, Song; Ekstrand, Laura; Grieve, Taylor; Eisenmann, David J.; Chumbley, L. Scott

    2012-09-01

    Often, the 3-D raw data coming from an optical profilometer contains spiky noises and irregular grid, which make it difficult to analyze and difficult to store because of the enormously large size. This paper is to address these two issues for an optical profilometer by substantially reducing the spiky noise of the 3-D raw data from an optical profilometer, and by rapidly re-sampling the raw data into regular grids at any pixel size and any orientation with advanced computer graphics tools. Experimental results will be presented to demonstrate the effectiveness of the proposed approach.

  3. Developments in the CCP4 molecular-graphics project.

    PubMed

    Potterton, Liz; McNicholas, Stuart; Krissinel, Eugene; Gruber, Jan; Cowtan, Kevin; Emsley, Paul; Murshudov, Garib N; Cohen, Serge; Perrakis, Anastassis; Noble, Martin

    2004-12-01

    Progress towards structure determination that is both high-throughput and high-value is dependent on the development of integrated and automatic tools for electron-density map interpretation and for the analysis of the resulting atomic models. Advances in map-interpretation algorithms are extending the resolution regime in which fully automatic tools can work reliably, but at present human intervention is required to interpret poor regions of macromolecular electron density, particularly where crystallographic data is only available to modest resolution [for example, I/sigma(I) < 2.0 for minimum resolution 2.5 A]. In such cases, a set of manual and semi-manual model-building molecular-graphics tools is needed. At the same time, converting the knowledge encapsulated in a molecular structure into understanding is dependent upon visualization tools, which must be able to communicate that understanding to others by means of both static and dynamic representations. CCP4 mg is a program designed to meet these needs in a way that is closely integrated with the ongoing development of CCP4 as a program suite suitable for both low- and high-intervention computational structural biology. As well as providing a carefully designed user interface to advanced algorithms of model building and analysis, CCP4 mg is intended to present a graphical toolkit to developers of novel algorithms in these fields.

  4. CEQer: A Graphical Tool for Copy Number and Allelic Imbalance Detection from Whole-Exome Sequencing Data

    PubMed Central

    Piazza, Rocco; Magistroni, Vera; Pirola, Alessandra; Redaelli, Sara; Spinelli, Roberta; Redaelli, Serena; Galbiati, Marta; Valletta, Simona; Giudici, Giovanni; Cazzaniga, Giovanni; Gambacorti-Passerini, Carlo

    2013-01-01

    Copy number alterations (CNA) are common events occurring in leukaemias and solid tumors. Comparative Genome Hybridization (CGH) is actually the gold standard technique to analyze CNAs; however, CGH analysis requires dedicated instruments and is able to perform only low resolution Loss of Heterozygosity (LOH) analyses. Here we present CEQer (Comparative Exome Quantification analyzer), a new graphical, event-driven tool for CNA/allelic-imbalance (AI) coupled analysis of exome sequencing data. By using case-control matched exome data, CEQer performs a comparative digital exonic quantification to generate CNA data and couples this information with exome-wide LOH and allelic imbalance detection. This data is used to build mixed statistical/heuristic models allowing the identification of CNA/AI events. To test our tool, we initially used in silico generated data, then we performed whole-exome sequencing from 20 leukemic specimens and corresponding matched controls and we analyzed the results using CEQer. Taken globally, these analyses showed that the combined use of comparative digital exon quantification and LOH/AI allows generating very accurate CNA data. Therefore, we propose CEQer as an efficient, robust and user-friendly graphical tool for the identification of CNA/AI in the context of whole-exome sequencing data. PMID:24124457

  5. Retrieval techniques and graphics displays using a computerized stellar data base

    NASA Technical Reports Server (NTRS)

    Mead, J.; Nagy, T. A.

    1977-01-01

    The paper describes a stellar data retrieval system for which the data base consists of 28 machine-readable astronomical catalogs. Eleven of these catalogs have been combined into the Goddard Cross Index (GCI), which serves as the computer entry point to these catalogs. The full data entry from any of the GCI catalogs can be retrieved in a single computer run. With this system, it is possible to prepare candidates for observation by searching the data base for stars with given characteristics. Generation of plots of all catalog stars in or near the telescope's field of view to scale of Palomar, other atlases, or to the telescope itself for use as observing charts or to aid in identifying unknown sources, can be accomplished.

  6. Anvil Tool in the Advanced Weather Interactive Processing System

    NASA Technical Reports Server (NTRS)

    Barrett, Joe, III; Bauman, William, III; Keen, Jeremy

    2007-01-01

    Meteorologists from the 45th Weather Squadron (45 WS) and Spaceflight Meteorology Group (SMG) have identified anvil forecasting as one of their most challenging tasks when predicting the probability of violations of the lightning Launch Commit Criteria and Space Shuttle Flight Rules. As a result, the Applied Meteorology Unit (AMU) created a graphical overlay tool for the Meteorological Interactive Data Display Systems (MIDDS) to indicate the threat of thunderstorm anvil clouds, using either observed or model forecast winds as input. In order for the Anvil Tool to remain available to the meteorologists, the AMU was tasked to transition the tool to the Advanced Weather interactive Processing System (AWIPS). This report describes the work done by the AMU to develop the Anvil Tool for AWIPS to create a graphical overlay depicting the threat from thunderstorm anvil clouds. The AWIPS Anvil Tool is based on the previously deployed AMU MIDDS Anvil Tool. SMG and 45 WS forecasters have used the MIDDS Anvil Tool during launch and landing operations. SMG's primary weather analysis and display system is now AWIPS and the 45 WS has plans to replace MIDDS with AWIPS. The Anvil Tool creates a graphic that users can overlay on satellite or radar imagery to depict the potential location of thunderstorm anvils one, two, and three hours into the future. The locations are based on an average of the upper-level observed or forecasted winds. The graphic includes 10 and 20 nm standoff circles centered at the location of interest, in addition to one-, two-, and three-hour arcs in the upwind direction. The arcs extend outward across a 30 degree sector width based on a previous AMU study which determined thunderstorm anvils move in a direction plus or minus 15 degrees of the upper-level (300- to 150-mb) wind direction. This report briefly describes the history of the MIDDS Anvil Tool and then explains how the initial development of the AWIPS Anvil Tool was carried out. After testing was performed by SMG, 45 WS, and AMU, a number of needed improvements were identified. A bug report document was created that showed the status of each bug and desired improvement. This report lists the improvements that were made to increase the accuracy and user-friendliness of the tool. Final testing was carried out and documented and then the final version of the software and Users Guide was provided to SMG and the 45 WS. Several possible future improvements to the tool are identified that would increase the flexibility of the tool. This report contains a brief history of the development of the Anvil Tool in MIDDS, and then describes the transition and development of software to AWIPS.

  7. Tools of the Courseware Trade: A Comparison of ToolBook 1.0 and HyperCard 2.0.

    ERIC Educational Resources Information Center

    Brader, Lorinda L.

    1990-01-01

    Compares two authoring tools that were developed to enable users without programing experience to create and modify software. HyperCard, designed for Macintosh microcomputers, and ToolBook, for microcomputers that run on MS-DOS, are compared in the areas of programing languages, graphics and printing capabilities, user interface, system…

  8. Software Tools on the Peregrine System | High-Performance Computing | NREL

    Science.gov Websites

    Debugger or performance analysis Tool for understanding the behavior of MPI applications. Intel VTune environment for statistical computing and graphics. VirtualGL/TurboVNC Visualization and analytics Remote Tools on the Peregrine System Software Tools on the Peregrine System NREL has a variety of

  9. Update: Advancement of Contact Dynamics Modeling for Human Spaceflight Simulation Applications

    NASA Technical Reports Server (NTRS)

    Brain, Thomas A.; Kovel, Erik B.; MacLean, John R.; Quiocho, Leslie J.

    2017-01-01

    Pong is a new software tool developed at the NASA Johnson Space Center that advances interference-based geometric contact dynamics based on 3D graphics models. The Pong software consists of three parts: a set of scripts to extract geometric data from 3D graphics models, a contact dynamics engine that provides collision detection and force calculations based on the extracted geometric data, and a set of scripts for visualizing the dynamics response with the 3D graphics models. The contact dynamics engine can be linked with an external multibody dynamics engine to provide an integrated multibody contact dynamics simulation. This paper provides a detailed overview of Pong including the overall approach and modeling capabilities, which encompasses force generation from contact primitives and friction to computational performance. Two specific Pong-based examples of International Space Station applications are discussed, and the related verification and validation using this new tool are also addressed.

  10. Graphical Environment Tools for Application to Gamma-Ray Energy Tracking Arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todd, Richard A.; Radford, David C.

    2013-12-30

    Highly segmented, position-sensitive germanium detector systems are being developed for nuclear physics research where traditional electronic signal processing with mixed analog and digital function blocks would be enormously complex and costly. Future systems will be constructed using pipelined processing of high-speed digitized signals as is done in the telecommunications industry. Techniques which provide rapid algorithm and system development for future systems are desirable. This project has used digital signal processing concepts and existing graphical system design tools to develop a set of re-usable modular functions and libraries targeted for the nuclear physics community. Researchers working with complex nuclear detector arraysmore » such as the Gamma-Ray Energy Tracking Array (GRETA) have been able to construct advanced data processing algorithms for implementation in field programmable gate arrays (FPGAs) through application of these library functions using intuitive graphical interfaces.« less

  11. [Computerized processing, using a Macintosh, of ambulatory arterial pressure measurements collected on a Spacelabs monitor].

    PubMed

    Chanudet, X; Bauduceau, B; Leguicher, A; Celton, H; Larroque, P

    1987-06-01

    The use of the Spacelabs blood pressure recorder has given rise to processing programs running on Apple II and IBM PC computers. The authors have written in M.S. BASIC (2.1) a program who take advantage of graphic abilities and easy manipulation on Macintosh. The software was designed to perform three tasks: Communicating between Macintosh and Spacelabs station using serial interface (RS 232) without requesting specific interface card. Editing a report on two pages: The first is the listing of 96 measurements (one by 15 minutes). The second provides: patient identification, height, weight, diagnosis. Graphic representation of measurements Systolic and diastolic blood pressure (BP) repartition histogram for 24 hours, day and night. Standard deviation and mean of pressure and heart rate (HR) for those periods. A third optionally gives hourly chronogram and diagrams for cumulated BP and HR. Creating a file: 550 records can be stored on a 800 K floppy disk. The file handles: data for each patient (excepted identification). Random access and revision of each parameter is possible. comparative reports for group patients and patient by patient analysing data with appropriate statistical test (ANOVA and correlation) are done.

  12. Automation of vibroacoustic data bank for random vibration criteria development. [for the space shuttle and launch vehicles

    NASA Technical Reports Server (NTRS)

    Ferebee, R. C.

    1982-01-01

    A computerized data bank system was developed for utilization of large amounts of vibration and acoustic data to formulate component random vibration design and test criteria. This system consists of a computer, graphics tablet, and a dry-silver hard copier which are all desk-top type hardware and occupy minimal space. The data bank contains data from the Saturn V and Titan III flight and static test programs. The vibration and acoustic data are stored in the form of power spectral density and one-third octave band plots over the frequency range from 20 to 2000 Hz. The data was stored by digitizing each spectral plot by tracing with the graphics tablet. The digitized data was statistically analyzed and the resulting 97.5% probability levels were stored on tape along with the appropriate structural parameters. Standard extrapolation procedures were programmed for prediction of component random vibration test criteria for new launch vehicle and payload configurations. This automated vibroacoustic data bank system greatly enhances the speed and accuracy of formulating vibration test criteria. In the future, the data bank will be expanded to include all data acquired from the space shuttle flight test program.

  13. A Graphics System for Pole-Zero Map Analysis.

    ERIC Educational Resources Information Center

    Beyer, William Fred, III

    Computer scientists have developed an interactive, graphical display system for pole-zero map analysis. They designed it for use as an educational tool in teaching introductory courses in automatic control systems. The facilities allow the user to specify a control system and an input function in the form of a pole-zero map and then examine the…

  14. A Graphical Journey of Innovative Organic Architectures that Have Improved Our Lives

    ERIC Educational Resources Information Center

    McGrath, Nicholas A.; Brichacek, Matthew; Njardarson, Jon T.

    2010-01-01

    A new free graphical teaching tool that highlights the beautiful organic architectures of the top selling pharmaceuticals is detailed on two posters. In addition to the multitude of teaching and data-mining opportunities these posters offer, they were also created to emphasize the central role organic chemists play in the development of new…

  15. Using Graphic Organizers as a Tool for the Development of Scientific Language

    ERIC Educational Resources Information Center

    Mercuri, Sandra P.

    2010-01-01

    This observational study examines the effectiveness of graphic organizers two elementary teachers in California, United States use to teach the content and the academic language of science. The study was done during the 2006-2007 school year. The data was collected through field-notes and the audio recording of instructional activities, and they…

  16. A Complete Interactive Graphical Computer-Aided Instruction System.

    ERIC Educational Resources Information Center

    Abrams, Steven Selby

    The use of interactive graphics in computer-aided instruction systems is discussed with emphasis placed on two requirements of such a system. The first is the need to provide the teacher with a useful tool with which to design and modify teaching sessions tailored to the individual needs and capabilities of the students. The second is the…

  17. ResidPlots-2: Computer Software for IRT Graphical Residual Analyses

    ERIC Educational Resources Information Center

    Liang, Tie; Han, Kyung T.; Hambleton, Ronald K.

    2009-01-01

    This article discusses the ResidPlots-2, a computer software that provides a powerful tool for IRT graphical residual analyses. ResidPlots-2 consists of two components: a component for computing residual statistics and another component for communicating with users and for plotting the residual graphs. The features of the ResidPlots-2 software are…

  18. Standardization of a Graphic Symbol System as an Alternative Communication Tool for Turkish

    ERIC Educational Resources Information Center

    Karal, Yasemin; Karal, Hasan; Silbir, Lokman; Altun, Taner

    2016-01-01

    Graphic symbols are commonly used across countries in order to support individuals with communicative deficiency. The literature review revealed the absence of such a system for Turkish socio-cultural context. In this study, the aim was to develop a symbol system appropriate for the Turkish socio-cultural context. The process began with studies…

  19. Clinical engineering department strategic graphical dashboard to enhance maintenance planning and asset management.

    PubMed

    Sloane, Elliot; Rosow, Eric; Adam, Joe; Shine, Dave

    2005-01-01

    The Clinical Engineering (a.k.a. Biomedical Engineering) Department has heretofore lagged in adoption of some of the leading-edge information system tools used in other industries. This present application is part of a DOD-funded SBIR grant to improve the overall management of medical technology, and describes the capabilities that Strategic Graphical Dashboards (SGDs) can afford. This SGD is built on top of an Oracle database, and uses custom-written graphic objects like gauges, fuel tanks, and Geographic Information System (GIS) maps to improve and accelerate decision making.

  20. GRASP/Ada: Graphical Representations of Algorithms, Structures, and Processes for Ada. The development of a program analysis environment for Ada: Reverse engineering tools for Ada, task 2, phase 3

    NASA Technical Reports Server (NTRS)

    Cross, James H., II

    1991-01-01

    The main objective is the investigation, formulation, and generation of graphical representations of algorithms, structures, and processes for Ada (GRASP/Ada). The presented task, in which various graphical representations that can be extracted or generated from source code are described and categorized, is focused on reverse engineering. The following subject areas are covered: the system model; control structure diagram generator; object oriented design diagram generator; user interface; and the GRASP library.

  1. The use of computer graphic simulation in the development of on-orbit tele-robotic systems

    NASA Technical Reports Server (NTRS)

    Fernandez, Ken; Hinman, Elaine

    1987-01-01

    This paper describes the use of computer graphic simulation techniques to resolve critical design and operational issues for robotic systems used for on-orbit operations. These issues are robot motion control, robot path-planning/verification, and robot dynamics. The major design issues in developing effective telerobotic systems are discussed, and the use of ROBOSIM, a NASA-developed computer graphic simulation tool, to address these issues is presented. Simulation plans for the Space Station and the Orbital Maneuvering Vehicle are presented and discussed.

  2. A Thesaurus-Linked Science Question-Banking System.

    ERIC Educational Resources Information Center

    Johnson, Sandra; Maher, Brian

    1984-01-01

    Outlines implementation and uses of the computerized question-banking system of the thesaurus-linked browse procedure used by APU National Assessment in Science Programme. The ROOT Thesaurus, a comprehensive indexing and searching tool for technological applications, is described and its modifications are discussed as the basis for the…

  3. With Corporate Help, We're Building the School of the Future Right Now.

    ERIC Educational Resources Information Center

    Herlihy, John J.; Day, C. William

    1989-01-01

    When Toyota Motor Manufacturing moved into a Kentucky community, it provided technological expertise and substantial financial backing to the school system. "Smart classrooms" are being designed with a spectrum of technological tools including computerized science laboratories and electronically linked media centers. (MLF)

  4. Rates of medical errors and preventable adverse events among hospitalized children following implementation of a resident handoff bundle.

    PubMed

    Starmer, Amy J; Sectish, Theodore C; Simon, Dennis W; Keohane, Carol; McSweeney, Maireade E; Chung, Erica Y; Yoon, Catherine S; Lipsitz, Stuart R; Wassner, Ari J; Harper, Marvin B; Landrigan, Christopher P

    2013-12-04

    Handoff miscommunications are a leading cause of medical errors. Studies comprehensively assessing handoff improvement programs are lacking. To determine whether introduction of a multifaceted handoff program was associated with reduced rates of medical errors and preventable adverse events, fewer omissions of key data in written handoffs, improved verbal handoffs, and changes in resident-physician workflow. Prospective intervention study of 1255 patient admissions (642 before and 613 after the intervention) involving 84 resident physicians (42 before and 42 after the intervention) from July-September 2009 and November 2009-January 2010 on 2 inpatient units at Boston Children's Hospital. Resident handoff bundle, consisting of standardized communication and handoff training, a verbal mnemonic, and a new team handoff structure. On one unit, a computerized handoff tool linked to the electronic medical record was introduced. The primary outcomes were the rates of medical errors and preventable adverse events measured by daily systematic surveillance. The secondary outcomes were omissions in the printed handoff document and resident time-motion activity. Medical errors decreased from 33.8 per 100 admissions (95% CI, 27.3-40.3) to 18.3 per 100 admissions (95% CI, 14.7-21.9; P < .001), and preventable adverse events decreased from 3.3 per 100 admissions (95% CI, 1.7-4.8) to 1.5 (95% CI, 0.51-2.4) per 100 admissions (P = .04) following the intervention. There were fewer omissions of key handoff elements on printed handoff documents, especially on the unit that received the computerized handoff tool (significant reductions of omissions in 11 of 14 categories with computerized tool; significant reductions in 2 of 14 categories without computerized tool). Physicians spent a greater percentage of time in a 24-hour period at the patient bedside after the intervention (8.3%; 95% CI 7.1%-9.8%) vs 10.6% (95% CI, 9.2%-12.2%; P = .03). The average duration of verbal handoffs per patient did not change. Verbal handoffs were more likely to occur in a quiet location (33.3%; 95% CI, 14.5%-52.2% vs 67.9%; 95% CI, 50.6%-85.2%; P = .03) and private location (50.0%; 95% CI, 30%-70% vs 85.7%; 95% CI, 72.8%-98.7%; P = .007) after the intervention. Implementation of a handoff bundle was associated with a significant reduction in medical errors and preventable adverse events among hospitalized children. Improvements in verbal and written handoff processes occurred, and resident workflow did not change adversely.

  5. Relationship between medication event rates and the Leapfrog computerized physician order entry evaluation tool.

    PubMed

    Leung, Alexander A; Keohane, Carol; Lipsitz, Stuart; Zimlichman, Eyal; Amato, Mary; Simon, Steven R; Coffey, Michael; Kaufman, Nathan; Cadet, Bismarck; Schiff, Gordon; Seger, Diane L; Bates, David W

    2013-06-01

    The Leapfrog CPOE evaluation tool has been promoted as a means of monitoring computerized physician order entry (CPOE). We sought to determine the relationship between Leapfrog scores and the rates of preventable adverse drug events (ADE) and potential ADE. A cross-sectional study of 1000 adult admissions in five community hospitals from October 1, 2008 to September 30, 2010 was performed. Observed rates of preventable ADE and potential ADE were compared with scores reported by the Leapfrog CPOE evaluation tool. The primary outcome was the rate of preventable ADE and the secondary outcome was the composite rate of preventable ADE and potential ADE. Leapfrog performance scores were highly related to the primary outcome. A 43% relative reduction in the rate of preventable ADE was predicted for every 5% increase in Leapfrog scores (rate ratio 0.57; 95% CI 0.37 to 0.88). In absolute terms, four fewer preventable ADE per 100 admissions were predicted for every 5% increase in overall Leapfrog scores (rate difference -4.2; 95% CI -7.4 to -1.1). A statistically significant relationship between Leapfrog scores and the secondary outcome, however, was not detected. Our findings support the use of the Leapfrog tool as a means of evaluating and monitoring CPOE performance after implementation, as addressed by current certification standards. Scores from the Leapfrog CPOE evaluation tool closely relate to actual rates of preventable ADE. Leapfrog testing may alert providers to potential vulnerabilities and highlight areas for further improvement.

  6. High performance interactive graphics for shower reconstruction in HPC, the DELPHI barrel electromagnetic calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stanescu, C.

    1990-08-01

    Complex software for shower reconstruction in DELPHI barrel electromagnetic calorimeter which deals, for each event, with great amounts of information, due to the high spatial resolution of this detector, needs powerful verification tools. An interactive graphics program, running on high performance graphics display system Whizzard 7555 from Megatek, was developed to display the logical steps in showers and their axes reconstruction. The program allows both operations on the image in real-time (rotation, translation and zoom) and the use of non-geometrical criteria to modify it (as the use of energy) thresholds for the representation of the elements that compound the showersmore » (or of the associated lego plots). For this purpose graphics objects associated to user parameters were defined. Instancing and modelling features of the native graphics library were extensively used.« less

  7. Creating Interactive Graphical Overlays in the Advanced Weather Interactive Processing System Using Shapefiles and DGM Files

    NASA Technical Reports Server (NTRS)

    Barrett, Joe H., III; Lafosse, Richard; Hood, Doris; Hoeth, Brian

    2007-01-01

    Graphical overlays can be created in real-time in the Advanced Weather Interactive Processing System (AWIPS) using shapefiles or Denver AWIPS Risk Reduction and Requirements Evaluation (DARE) Graphics Metafile (DGM) files. This presentation describes how to create graphical overlays on-the-fly for AWIPS, by using two examples of AWIPS applications that were created by the Applied Meteorology Unit (AMU) located at Cape Canaveral Air Force Station (CCAFS), Florida. The first example is the Anvil Threat Corridor Forecast Tool, which produces a shapefile that depicts a graphical threat corridor of the forecast movement of thunderstorm anvil clouds, based on the observed or forecast upper-level winds. This tool is used by the Spaceflight Meteorology Group (SMG) at Johnson Space Center, Texas and 45th Weather Squadron (45 WS) at CCAFS to analyze the threat of natural or space vehicle-triggered lightning over a location. The second example is a launch and landing trajectory tool that produces a DGM file that plots the ground track of space vehicles during launch or landing. The trajectory tool can be used by SMG and the 45 WS forecasters to analyze weather radar imagery along a launch or landing trajectory. The presentation will list the advantages and disadvantages of both file types for creating interactive graphical overlays in future AWIPS applications. Shapefiles are a popular format used extensively in Geographical Information Systems. They are usually used in AWIPS to depict static map backgrounds. A shapefile stores the geometry and attribute information of spatial features in a dataset (ESRI 1998). Shapefiles can contain point, line, and polygon features. Each shapefile contains a main file, index file, and a dBASE table. The main file contains a record for each spatial feature, which describes the feature with a list of its vertices. The index file contains the offset of each record from the beginning of the main file. The dBASE table contains records for each attribute. Attributes are commonly used to label spatial features. Shapefiles can be viewed, but not created in AWIPS. As a result, either third-party software can be installed on an AWIPS workstation, or new software must be written to create shapefiles in the correct format.

  8. IVisTMSA: Interactive Visual Tools for Multiple Sequence Alignments.

    PubMed

    Pervez, Muhammad Tariq; Babar, Masroor Ellahi; Nadeem, Asif; Aslam, Naeem; Naveed, Nasir; Ahmad, Sarfraz; Muhammad, Shah; Qadri, Salman; Shahid, Muhammad; Hussain, Tanveer; Javed, Maryam

    2015-01-01

    IVisTMSA is a software package of seven graphical tools for multiple sequence alignments. MSApad is an editing and analysis tool. It can load 409% more data than Jalview, STRAP, CINEMA, and Base-by-Base. MSA comparator allows the user to visualize consistent and inconsistent regions of reference and test alignments of more than 21-MB size in less than 12 seconds. MSA comparator is 5,200% efficient and more than 40% efficient as compared to BALiBASE c program and FastSP, respectively. MSA reconstruction tool provides graphical user interfaces for four popular aligners and allows the user to load several sequence files at a time. FASTA generator converts seven formats of alignments of unlimited size into FASTA format in a few seconds. MSA ID calculator calculates identity matrix of more than 11,000 sequences with a sequence length of 2,696 base pairs in less than 100 seconds. Tree and Distance Matrix calculation tools generate phylogenetic tree and distance matrix, respectively, using neighbor joining% identity and BLOSUM 62 matrix.

  9. Determination and representation of electric charge distributions associated with adverse weather conditions

    NASA Technical Reports Server (NTRS)

    Rompala, John T.

    1992-01-01

    Algorithms are presented for determining the size and location of electric charges which model storm systems and lightning strikes. The analysis utilizes readings from a grid of ground level field mills and geometric constraints on parameters to arrive at a representative set of charges. This set is used to generate three dimensional graphical depictions of the set as well as contour maps of the ground level electrical environment over the grid. The composite, analytic and graphic package is demonstrated and evaluated using controlled input data and archived data from a storm system. The results demonstrate the packages utility as: an operational tool in appraising adverse weather conditions; a research tool in studies of topics such as storm structure, storm dynamics, and lightning; and a tool in designing and evaluating grid systems.

  10. User interface support

    NASA Technical Reports Server (NTRS)

    Lewis, Clayton; Wilde, Nick

    1989-01-01

    Space construction will require heavy investment in the development of a wide variety of user interfaces for the computer-based tools that will be involved at every stage of construction operations. Using today's technology, user interface development is very expensive for two reasons: (1) specialized and scarce programming skills are required to implement the necessary graphical representations and complex control regimes for high-quality interfaces; (2) iteration on prototypes is required to meet user and task requirements, since these are difficult to anticipate with current (and foreseeable) design knowledge. We are attacking this problem by building a user interface development tool based on extensions to the spreadsheet model of computation. The tool provides high-level support for graphical user interfaces and permits dynamic modification of interfaces, without requiring conventional programming concepts and skills.

  11. Visualising associations between paired ‘omics’ data sets

    PubMed Central

    2012-01-01

    Background Each omics platform is now able to generate a large amount of data. Genomics, proteomics, metabolomics, interactomics are compiled at an ever increasing pace and now form a core part of the fundamental systems biology framework. Recently, several integrative approaches have been proposed to extract meaningful information. However, these approaches lack of visualisation outputs to fully unravel the complex associations between different biological entities. Results The multivariate statistical approaches ‘regularized Canonical Correlation Analysis’ and ‘sparse Partial Least Squares regression’ were recently developed to integrate two types of highly dimensional ‘omics’ data and to select relevant information. Using the results of these methods, we propose to revisit few graphical outputs to better understand the relationships between two ‘omics’ data and to better visualise the correlation structure between the different biological entities. These graphical outputs include Correlation Circle plots, Relevance Networks and Clustered Image Maps. We demonstrate the usefulness of such graphical outputs on several biological data sets and further assess their biological relevance using gene ontology analysis. Conclusions Such graphical outputs are undoubtedly useful to aid the interpretation of these promising integrative analysis tools and will certainly help in addressing fundamental biological questions and understanding systems as a whole. Availability The graphical tools described in this paper are implemented in the freely available R package mixOmics and in its associated web application. PMID:23148523

  12. SystemSketch Poster

    EPA Science Inventory

    SystemSketch is a dynamic, graphic visualization tool to help stakeholders better understand system context and access information resources.  It is constructed using the Driver-Pressure-State-Impact-Response framework, and functions both as a stand-alone tool and as a component ...

  13. Heuristic Evaluation and Usability Testing of a Computerized Patient-Reported Outcomes Survey for Headache Sufferers

    PubMed Central

    Saris-Baglama, Renee N.; Smith, Kevin J.; DeRosa, Michael A.; Paulsen, Christine A.; Hogue, Sarah J.

    2011-01-01

    Abstract Objective The aim of this study was to evaluate usability of a prototype tablet PC-administered computerized adaptive test (CAT) of headache impact and patient feedback report, referred to as HEADACHE-CAT. Materials and Methods Heuristic evaluation specialists (n = 2) formed a consensus opinion on the application's strengths and areas for improvement based on general usability principles and human factors research. Usability testing involved structured interviews with headache sufferers (n = 9) to assess how they interacted with and navigated through the application, and to gather input on the survey and report interface, content, visual design, navigation, instructions, and user preferences. Results Specialists identified the need for improved instructions and text formatting, increased font size, page setup that avoids scrolling, and simplified presentation of feedback reports. Participants found the tool useful, and indicated a willingness to complete it again and recommend it to their healthcare provider. However, some had difficulty using the onscreen keyboard and autoadvance option; understanding the difference between generic and headache-specific questions; and interpreting score reports. Conclusions Heuristic evaluation and user testing can help identify usability problems in the early stages of application development, and improve the construct validity of electronic assessments such as the HEADACHE-CAT. An improved computerized HEADACHE-CAT measure can offer headache sufferers an efficient tool to increase patient self-awareness, monitor headaches over time, aid patient–provider communications, and improve quality of life. PMID:21214341

  14. Simulation environment and graphical visualization environment: a COPD use-case.

    PubMed

    Huertas-Migueláñez, Mercedes; Mora, Daniel; Cano, Isaac; Maier, Dieter; Gomez-Cabrero, David; Lluch-Ariet, Magí; Miralles, Felip

    2014-11-28

    Today, many different tools are developed to execute and visualize physiological models that represent the human physiology. Most of these tools run models written in very specific programming languages which in turn simplify the communication among models. Nevertheless, not all of these tools are able to run models written in different programming languages. In addition, interoperability between such models remains an unresolved issue. In this paper we present a simulation environment that allows, first, the execution of models developed in different programming languages and second the communication of parameters to interconnect these models. This simulation environment, developed within the Synergy-COPD project, aims at helping and supporting bio-researchers and medical students understand the internal mechanisms of the human body through the use of physiological models. This tool is composed of a graphical visualization environment, which is a web interface through which the user can interact with the models, and a simulation workflow management system composed of a control module and a data warehouse manager. The control module monitors the correct functioning of the whole system. The data warehouse manager is responsible for managing the stored information and supporting its flow among the different modules. It has been proved that the simulation environment presented here allows the user to research and study the internal mechanisms of the human physiology by the use of models via a graphical visualization environment. A new tool for bio-researchers is ready for deployment in various use cases scenarios.

  15. Supporting geoscience with graphical-user-interface Internet tools for the Macintosh

    NASA Astrophysics Data System (ADS)

    Robin, Bernard

    1995-07-01

    This paper describes a suite of Macintosh graphical-user-interface (GUI) software programs that can be used in conjunction with the Internet to support geoscience education. These software programs allow science educators to access and retrieve a large body of resources from an increasing number of network sites, taking advantage of the intuitive, simple-to-use Macintosh operating system. With these tools, educators easily can locate, download, and exchange not only text files but also sound resources, video movie clips, and software application files from their desktop computers. Another major advantage of these software tools is that they are available at no cost and may be distributed freely. The following GUI software tools are described including examples of how they can be used in an educational setting: ∗ Eudora—an e-mail program ∗ NewsWatcher—a newsreader ∗ TurboGopher—a Gopher program ∗ Fetch—a software application for easy File Transfer Protocol (FTP) ∗ NCSA Mosaic—a worldwide hypertext browsing program. An explosive growth of online archives currently is underway as new electronic sites are being added continuously to the Internet. Many of these resources may be of interest to science educators who learn they can share not only ASCII text files, but also graphic image files, sound resources, QuickTime movie clips, and hypermedia projects with colleagues from locations around the world. These powerful, yet simple to learn GUI software tools are providing a revolution in how knowledge can be accessed, retrieved, and shared.

  16. eRNA: a graphic user interface-based tool optimized for large data analysis from high-throughput RNA sequencing

    PubMed Central

    2014-01-01

    Background RNA sequencing (RNA-seq) is emerging as a critical approach in biological research. However, its high-throughput advantage is significantly limited by the capacity of bioinformatics tools. The research community urgently needs user-friendly tools to efficiently analyze the complicated data generated by high throughput sequencers. Results We developed a standalone tool with graphic user interface (GUI)-based analytic modules, known as eRNA. The capacity of performing parallel processing and sample management facilitates large data analyses by maximizing hardware usage and freeing users from tediously handling sequencing data. The module miRNA identification” includes GUIs for raw data reading, adapter removal, sequence alignment, and read counting. The module “mRNA identification” includes GUIs for reference sequences, genome mapping, transcript assembling, and differential expression. The module “Target screening” provides expression profiling analyses and graphic visualization. The module “Self-testing” offers the directory setups, sample management, and a check for third-party package dependency. Integration of other GUIs including Bowtie, miRDeep2, and miRspring extend the program’s functionality. Conclusions eRNA focuses on the common tools required for the mapping and quantification analysis of miRNA-seq and mRNA-seq data. The software package provides an additional choice for scientists who require a user-friendly computing environment and high-throughput capacity for large data analysis. eRNA is available for free download at https://sourceforge.net/projects/erna/?source=directory. PMID:24593312

  17. eRNA: a graphic user interface-based tool optimized for large data analysis from high-throughput RNA sequencing.

    PubMed

    Yuan, Tiezheng; Huang, Xiaoyi; Dittmar, Rachel L; Du, Meijun; Kohli, Manish; Boardman, Lisa; Thibodeau, Stephen N; Wang, Liang

    2014-03-05

    RNA sequencing (RNA-seq) is emerging as a critical approach in biological research. However, its high-throughput advantage is significantly limited by the capacity of bioinformatics tools. The research community urgently needs user-friendly tools to efficiently analyze the complicated data generated by high throughput sequencers. We developed a standalone tool with graphic user interface (GUI)-based analytic modules, known as eRNA. The capacity of performing parallel processing and sample management facilitates large data analyses by maximizing hardware usage and freeing users from tediously handling sequencing data. The module miRNA identification" includes GUIs for raw data reading, adapter removal, sequence alignment, and read counting. The module "mRNA identification" includes GUIs for reference sequences, genome mapping, transcript assembling, and differential expression. The module "Target screening" provides expression profiling analyses and graphic visualization. The module "Self-testing" offers the directory setups, sample management, and a check for third-party package dependency. Integration of other GUIs including Bowtie, miRDeep2, and miRspring extend the program's functionality. eRNA focuses on the common tools required for the mapping and quantification analysis of miRNA-seq and mRNA-seq data. The software package provides an additional choice for scientists who require a user-friendly computing environment and high-throughput capacity for large data analysis. eRNA is available for free download at https://sourceforge.net/projects/erna/?source=directory.

  18. A Markov Model Analysis of Problem-Solving Progress.

    ERIC Educational Resources Information Center

    Vendlinski, Terry

    This study used a computerized simulation and problem-solving tool along with artificial neural networks (ANN) as pattern recognizers to identify the common types of strategies high school and college undergraduate chemistry students would use to solve qualitative chemistry problems. Participants were 134 high school chemistry students who used…

  19. PREVENTING CONTAMINATION OF PUBLIC WATER SUPPLY WELLS USING COMPUTERIZED MODELING AND MAPPING TOOLS

    EPA Science Inventory

    The EPA Office of Research and Development and the Office of Ground Water and Drinking Water have collaborated since 1998 on the development of a public domain ground-water flow modeling system designed to facilitate capture zone delineation and protection area mapping for public...

  20. Development and validation of a survey instrument for assessing prescribers' perception of computerized drug-drug interaction alerts.

    PubMed

    Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D

    2011-12-01

    To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.

  1. Using Comic Books and Graphic Novels to Improve and Facilitate Community College Students' Literacy Development

    ERIC Educational Resources Information Center

    Burke, Brian Patrick

    2012-01-01

    This study evaluated how comic books and graphic novels enhanced the reading comprehension of the students enrolled in the intermediate reading course at Western Pennsylvania Community College. The three research questions are: (1) How can a developmental reading course make use of comics as a learning tool? (2) What impact does reading comics…

  2. An Item Response Unfolding Model for Graphic Rating Scales

    ERIC Educational Resources Information Center

    Liu, Ying

    2009-01-01

    The graphic rating scale, a measurement tool used in many areas of psychology, usually takes a form of a fixed-length line segment, with both ends bounded and labeled as extreme responses. The raters mark somewhere on the line, and the length of the line segment from one endpoint to the mark is taken as the measure. An item response unfolding…

  3. Graphical Representations and Odds Ratios in a Distance-Association Model for the Analysis of Cross-Classified Data

    ERIC Educational Resources Information Center

    de Rooij, Mark; Heiser, Willem J.

    2005-01-01

    Although RC(M)-association models have become a generally useful tool for the analysis of cross-classified data, the graphical representation resulting from such an analysis can at times be misleading. The relationships present between row category points and column category points cannot be interpreted by inter point distances but only through…

  4. Three Dimensional Display Of Meteorological Scientific Data

    NASA Astrophysics Data System (ADS)

    Grotch, Stanley L.

    1988-01-01

    Even a cursory reading of any daily newspaper shows that we are in the midst of a dramatic revolution in computer graphics. Virtually every day some new piece of hardware or software is announced, adding to the tools available to the working scientist. Three dimensional graphics form a significant part of this revolution having become virtually commonplace in advertising and on television.

  5. Get Your Head into the Clouds: Using Word Clouds for Analyzing Qualitative Assessment Data

    ERIC Educational Resources Information Center

    DePaolo, Concetta A.; Wilkinson, Kelly

    2014-01-01

    Word clouds (or tag clouds) are popular, fun ways to display text data in graphical form; however, we contend that they can also be useful tools in assessment. Using word clouds, instructors can quickly and easily produce graphical depictions of text representing student knowledge. By investigating the patterns of words or phrases, or lack…

  6. Monitoring an Online Course with the GISMO Tool: A Case Study

    ERIC Educational Resources Information Center

    Mazza, Riccardo; Botturi, Luca

    2007-01-01

    This article presents GISMO, a novel, open source, graphic student-tracking tool integrated into Moodle. GISMO represents a further step in information visualization applied to education, and also a novelty in the field of learning management systems applications. The visualizations of the tool, its uses and the benefits it can bring are…

  7. Engineering visualization utilizing advanced animation

    NASA Technical Reports Server (NTRS)

    Sabionski, Gunter R.; Robinson, Thomas L., Jr.

    1989-01-01

    Engineering visualization is the use of computer graphics to depict engineering analysis and simulation in visual form from project planning through documentation. Graphics displays let engineers see data represented dynamically which permits the quick evaluation of results. The current state of graphics hardware and software generally allows the creation of two types of 3D graphics. The use of animated video as an engineering visualization tool is presented. The engineering, animation, and videography aspects of animated video production are each discussed. Specific issues include the integration of staffing expertise, hardware, software, and the various production processes. A detailed explanation of the animation process reveals the capabilities of this unique engineering visualization method. Automation of animation and video production processes are covered and future directions are proposed.

  8. Transportable Applications Environment (TAE) Plus: A NASA tool for building and managing graphical user interfaces

    NASA Technical Reports Server (NTRS)

    Szczur, Martha R.

    1993-01-01

    The Transportable Applications Environment (TAE) Plus, developed at NASA's Goddard Space Flight Center, is an advanced portable user interface development which simplifies the process of creating and managing complex application graphical user interfaces (GUI's). TAE Plus supports the rapid prototyping of GUI's and allows applications to be ported easily between different platforms. This paper will discuss the capabilities of the TAE Plus tool, and how it makes the job of designing and developing GUI's easier for application developers. TAE Plus is being applied to many types of applications, and this paper discusses how it has been used both within and outside NASA.

  9. Usability analysis of 2D graphics software for designing technical clothing.

    PubMed

    Teodoroski, Rita de Cassia Clark; Espíndola, Edilene Zilma; Silva, Enéias; Moro, Antônio Renato Pereira; Pereira, Vera Lucia D V

    2012-01-01

    With the advent of technology, the computer became a working tool increasingly present in companies. Its purpose is to increase production and reduce the inherent errors in manual production. The aim of this study was to analyze the usability of 2D graphics software in creating clothing designs by a professional during his work. The movements of the mouse, keyboard and graphical tools were monitored in real time by software Camtasia 7® installed on the user's computer. To register the use of mouse and keyboard we used auxiliary software called MouseMeter®, which quantifies the number of times they pressed the right, middle and left mouse's buttons, the keyboard and also the distance traveled in meters by the cursor on the screen. Data was collected in periods of 15 minutes, 1 hour and 8 hours, consecutively. The results showed that the job is considered repetitive and high demands physical efforts, which can lead to the appearance of repetitive strain injuries. Thus, the goal of minimizing operator efforts and thereby enhance the usability of the examined tool, becomes imperative to replace the mouse by a device called tablet, which also offers an electronic pen and a drawing platform for design development.

  10. A prototype of a beam steering assistant tool for accelerator operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Bickley; P. Chevtsov

    2006-10-24

    The CEBAF accelerator provides nuclear physics experiments at Jefferson Lab with high quality electron beams. Three experimental end stations can simultaneously receive the beams with different energies and intensities. For each operational mode, the accelerator setup procedures are complicated and require very careful checking of beam spot sizes and positions on multiple beam viewers. To simplify these procedures and make them reproducible, a beam steering assistant GUI tool has been created. The tool is implemented as a multi-window control screen. The screen has an interactive graphical object window, which is an overlay on top of a digitized live video imagemore » from a beam viewer. It allows a user to easily create and edit any graphical objects consisting of text, ellipses, and lines, right above the live beam viewer image and then save them in a file that is called a beam steering template. The template can show, for example, the area within which the beam must always be on the viewer. Later, this template can be loaded in the interactive graphical object window to help accelerator operators steer the beam to the specified area on the viewer.« less

  11. Model-based reasoning for system and software engineering: The Knowledge From Pictures (KFP) environment

    NASA Technical Reports Server (NTRS)

    Bailin, Sydney; Paterra, Frank; Henderson, Scott; Truszkowski, Walt

    1993-01-01

    This paper presents a discussion of current work in the area of graphical modeling and model-based reasoning being undertaken by the Automation Technology Section, Code 522.3, at Goddard. The work was initially motivated by the growing realization that the knowledge acquisition process was a major bottleneck in the generation of fault detection, isolation, and repair (FDIR) systems for application in automated Mission Operations. As with most research activities this work started out with a simple objective: to develop a proof-of-concept system demonstrating that a draft rule-base for a FDIR system could be automatically realized by reasoning from a graphical representation of the system to be monitored. This work was called Knowledge From Pictures (KFP) (Truszkowski et. al. 1992). As the work has successfully progressed the KFP tool has become an environment populated by a set of tools that support a more comprehensive approach to model-based reasoning. This paper continues by giving an overview of the graphical modeling objectives of the work, describing the three tools that now populate the KFP environment, briefly presenting a discussion of related work in the field, and by indicating future directions for the KFP environment.

  12. Hierarchical programming for data storage and visualization

    USGS Publications Warehouse

    Donovan, John M.; Smith, Peter E.; ,

    2001-01-01

    Graphics software is an essential tool for interpreting, analyzing, and presenting data from multidimensional hydrodynamic models used in estuarine and coastal ocean studies. The post-processing of time-varying three-dimensional model output presents unique requirements for data visualization because of the large volume of data that can be generated and the multitude of time scales that must be examined. Such data can relate to estuarine or coastal ocean environments and come from numerical models or field instruments. One useful software tool for the display, editing, visualization, and printing of graphical data is the Gr application, written by the first author for use in U.S. Geological Survey San Francisco Bay Program. The Gr application has been made available to the public via the Internet since the year 2000. The Gr application is written in the Java (Sun Microsystems, Nov. 29, 2001) programming language and uses the Extensible Markup Language standard for hierarchical data storage. Gr presents a hierarchy of objects to the user that can be edited using a common interface. Java's object-oriented capabilities allow Gr to treat data, graphics, and tools equally and to save them all to a single XML file.

  13. Improving designer productivity

    NASA Technical Reports Server (NTRS)

    Hill, Gary C.

    1992-01-01

    Designer and design team productivity improves with skill, experience, and the tools available. The design process involves numerous trials and errors, analyses, refinements, and addition of details. Computerized tools have greatly speeded the analysis, and now new theories and methods, emerging under the label Artificial Intelligence (AI), are being used to automate skill and experience. These tools improve designer productivity by capturing experience, emulating recognized skillful designers, and making the essence of complex programs easier to grasp. This paper outlines the aircraft design process in today's technology and business climate, presenting some of the challenges ahead and some of the promising AI methods for meeting those challenges.

  14. Environmental databases and other computerized information tools

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia

    1995-01-01

    Increasing environmental legislation has brought about the development of many new environmental databases and software application packages to aid in the quest for environmental compliance. These databases and software packages are useful tools and applicable to a wide range of environmental areas from atmospheric modeling to materials replacement technology. The great abundance of such products and services can be very overwhelming when trying to identify the tools which best meet specific needs. This paper will discuss the types of environmental databases and software packages available. This discussion will also encompass the affected environmental areas of concern, product capabilities, and hardware requirements for product utilization.

  15. Analog-to-digital clinical data collection on networked workstations with graphic user interface.

    PubMed

    Lunt, D

    1991-02-01

    An innovative respiratory examination system has been developed that combines physiological response measurement, real-time graphic displays, user-driven operating sequences, and networked file archiving and review into a scientific research and clinical diagnosis tool. This newly constructed computer network is being used to enhance the research center's ability to perform patient pulmonary function examinations. Respiratory data are simultaneously acquired and graphically presented during patient breathing maneuvers and rapidly transformed into graphic and numeric reports, suitable for statistical analysis or database access. The environment consists of the hardware (Macintosh computer, MacADIOS converters, analog amplifiers), the software (HyperCard v2.0, HyperTalk, XCMDs), and the network (AppleTalk, fileservers, printers) as building blocks for data acquisition, analysis, editing, and storage. System operation modules include: Calibration, Examination, Reports, On-line Help Library, Graphic/Data Editing, and Network Storage.

  16. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.

  17. Mikado: A graphic program

    NASA Astrophysics Data System (ADS)

    Secretan, Y.

    A discussion of the modular program Mikado is presented. Mikado was developed with the goal of creating a flexible graphic tool to display and help analyze the results of finite element fluid flow computations. Mikado works on unstructured meshes, with elements of mixed geometric type, but also offers the possibility of using structured meshes. The program can be operated by both menu and mouse (interactive), or by command file (batch). Mikado is written in FORTRAN, except for a few system dependent subroutines which are in C. It runs presently on Silicon Graphics' workstations and could be easily ported to the IBM-RISC System/6000 family of workstations.

  18. A graphic system for telemetry monitoring and procedure performing at the Telecom SCC

    NASA Technical Reports Server (NTRS)

    Loubeyre, Jean Philippe

    1994-01-01

    The increasing amount of telemetry parameters and the increasing complexity of procedures used for the in-orbit satellite follow-up has led to the development of new tools for telemetry monitoring and procedures performing. The name of the system presented here is Graphic Server. It provides an advanced graphic representation of the satellite subsystems, including real-time telemetry and alarm displaying, and a powerful help for decision making with on line contingency procedures. Used for 2.5 years at the TELECOM S.C.C. for procedure performing, it has become an essential part of the S.C.C.

  19. The Capabilities of the Graphical Observation Scheduling System (GROSS) as Used by the Astro-2 Spacelab Mission

    NASA Technical Reports Server (NTRS)

    Phillips, Shaun

    1996-01-01

    The Graphical Observation Scheduling System (GROSS) and its functionality and editing capabilities are reported on. The GROSS system was developed as a replacement for a suite of existing programs and associated processes with the aim of: providing a software tool that combines the functionality of several of the existing programs, and provides a Graphical User Interface (GUI) that gives greater data visibility and editing capabilities. It is considered that the improved editing capability provided by this approach enhanced the efficiency of the second astronomical Spacelab mission's (ASTRO-2) mission planning.

  20. Reduction in patient burdens with graphical computerized adaptive testing on the ADL scale: tool development and simulation

    PubMed Central

    Chien, Tsair-Wei; Wu, Hing-Man; Wang, Weng-Chung; Castillo, Roberto Vasquez; Chou, Willy

    2009-01-01

    Background The aim of this study was to verify the effectiveness and efficacy of saving time and reducing burden for patients, nurses, and even occupational therapists through computer adaptive testing (CAT). Methods Based on an item bank of the Barthel Index (BI) and the Frenchay Activities Index (FAI) for assessing comprehensive activities of daily living (ADL) function in stroke patients, we developed a visual basic application (VBA)-Excel CAT module, and (1) investigated whether the averaged test length via CAT is shorter than that of the traditional all-item-answered non-adaptive testing (NAT) approach through simulation, (2) illustrated the CAT multimedia on a tablet PC showing data collection and response errors of ADL clinical functional measures in stroke patients, and (3) demonstrated the quality control of endorsing scale with fit statistics to detect responding errors, which will be further immediately reconfirmed by technicians once patient ends the CAT assessment. Results The results show that endorsed items could be shorter on CAT (M = 13.42) than on NAT (M = 23) at 41.64% efficiency in test length. However, averaged ability estimations reveal insignificant differences between CAT and NAT. Conclusion This study found that mobile nursing services, placed at the bedsides of patients could, through the programmed VBA-Excel CAT module, reduce the burden to patients and save time, more so than the traditional NAT paper-and-pencil testing appraisals. PMID:19416521

  1. Sharing adverse drug event data using business intelligence technology.

    PubMed

    Horvath, Monica M; Cozart, Heidi; Ahmad, Asif; Langman, Matthew K; Ferranti, Jeffrey

    2009-03-01

    Duke University Health System uses computerized adverse drug event surveillance as an integral part of medication safety at 2 community hospitals and an academic medical center. This information must be swiftly communicated to organizational patient safety stakeholders to find opportunities to improve patient care; however, this process is encumbered by highly manual methods of preparing the data. Following the examples of other industries, we deployed a business intelligence tool to provide dynamic safety reports on adverse drug events. Once data were migrated into the health system data warehouse, we developed census-adjusted reports with user-driven prompts. Drill down functionality enables navigation from aggregate trends to event details by clicking report graphics. Reports can be accessed by patient safety leadership either through an existing safety reporting portal or the health system performance improvement Web site. Elaborate prompt screens allow many varieties of reports to be created quickly by patient safety personnel without consultation with the research analyst. The reduction in research analyst workload because of business intelligence implementation made this individual available to additional patient safety projects thereby leveraging their talents more effectively. Dedicated liaisons are essential to ensure clear communication between clinical and technical staff throughout the development life cycle. Design and development of the business intelligence model for adverse drug event data must reflect the eccentricities of the operational system, especially as new areas of emphasis evolve. Future usability studies examining the data presentation and access model are needed.

  2. Intuitive Tools for the Design and Analysis of Communication Payloads for Satellites

    NASA Technical Reports Server (NTRS)

    Culver, Michael R.; Soong, Christine; Warner, Joseph D.

    2014-01-01

    In an effort to make future communications satellite payload design more efficient and accessible, two tools were created with intuitive graphical user interfaces (GUIs). The first tool allows payload designers to graphically design their payload by using simple drag and drop of payload components onto a design area within the program. Information about each picked component is pulled from a database of common space-qualified communication components sold by commerical companies. Once a design is completed, various reports can be generated, such as the Master Equipment List. The second tool is a link budget calculator designed specifically for ease of use. Other features of this tool include being able to access a database of NASA ground based apertures for near Earth and Deep Space communication, the Tracking and Data Relay Satellite System (TDRSS) base apertures, and information about the solar system relevant to link budget calculations. The link budget tool allows for over 50 different combinations of user inputs, eliminating the need for multiple spreadsheets and the user errors associated with using them. Both of the aforementioned tools increase the productivity of space communication systems designers, and have the colloquial latitude to allow non-communication experts to design preliminary communication payloads.

  3. A review of decision support, risk communication and patient information tools for thrombolytic treatment in acute stroke: lessons for tool developers

    PubMed Central

    2013-01-01

    Background Tools to support clinical or patient decision-making in the treatment/management of a health condition are used in a range of clinical settings for numerous preference-sensitive healthcare decisions. Their impact in clinical practice is largely dependent on their quality across a range of domains. We critically analysed currently available tools to support decision making or patient understanding in the treatment of acute ischaemic stroke with intravenous thrombolysis, as an exemplar to provide clinicians/researchers with practical guidance on development, evaluation and implementation of such tools for other preference-sensitive treatment options/decisions in different clinical contexts. Methods Tools were identified from bibliographic databases, Internet searches and a survey of UK and North American stroke networks. Two reviewers critically analysed tools to establish: information on benefits/risks of thrombolysis included in tools, and the methods used to convey probabilistic information (verbal descriptors, numerical and graphical); adherence to guidance on presenting outcome probabilities (IPDASi probabilities items) and information content (Picker Institute Checklist); readability (Fog Index); and the extent that tools had comprehensive development processes. Results Nine tools of 26 identified included information on a full range of benefits/risks of thrombolysis. Verbal descriptors, frequencies and percentages were used to convey probabilistic information in 20, 19 and 18 tools respectively, whilst nine used graphical methods. Shortcomings in presentation of outcome probabilities (e.g. omitting outcomes without treatment) were identified. Patient information tools had an aggregate median Fog index score of 10. None of the tools had comprehensive development processes. Conclusions Tools to support decision making or patient understanding in the treatment of acute stroke with thrombolysis have been sub-optimally developed. Development of tools should utilise mixed methods and strategies to meaningfully involve clinicians, patients and their relatives in an iterative design process; include evidence-based methods to augment interpretability of textual and probabilistic information (e.g. graphical displays showing natural frequencies) on the full range of outcome states associated with available options; and address patients with different levels of health literacy. Implementation of tools will be enhanced when mechanisms are in place to periodically assess the relevance of tools and where necessary, update the mode of delivery, form and information content. PMID:23777368

  4. Computerized engineering logic for procurement and dedication processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tulay, M.P.

    1996-12-31

    This paper summarizes the work performed for designing the system and especially for calculating on-line expected performance and gives some significant results. In an attempt to better meet the needs of operations and maintenance organizations, many nuclear utility procurement engineering groups have simplified their procedures, developed on-line tools for performing the specification of replacement items, and developed relational databases containing part-level information necessary to automate the procurement process. Although these improvements have helped to reduce the engineering necessary to properly specify and accept/dedicate items for nuclear safety-related applications, a number of utilities have recognized that additional long-term savings can bemore » realized by integrating a computerized logic to assist technical procurement engineering personnel.« less

  5. The horizontal computerized rotational impulse test.

    PubMed

    Furman, Joseph M; Shirey, Ian; Roxberg, Jillyn; Kiderman, Alexander

    2016-01-01

    Whole-body impulsive rotations were used to overcome several limitations associated with manual head impulse testing. A computer-controlled rotational chair delivered brief, whole-body, earth-vertical axis yaw impulsive rotations while eye movements were measured using video-oculography. Results from an unselected group of 20 patients with dizziness and a group of 22 control subjects indicated that the horizontal computerized rotational head impulse test (crHIT) is well-tolerated and provides an estimate of unidirectional vestibulo-ocular reflex gain comparable to results from caloric testing. This study demonstrates that the horizontal crHIT is a new assessment tool that overcomes many of the limitations of manual head impulse testing and provides a reliable laboratory-based measure of unilateral horizontal semicircular canal function.

  6. The Computerized Perceptual Motor Skills Assessment: A new visual perceptual motor skills evaluation tool for children in early elementary grades.

    PubMed

    Howe, Tsu-Hsin; Chen, Hao-Ling; Lee, Candy Chieh; Chen, Ying-Dar; Wang, Tien-Ni

    2017-10-01

    Visual perceptual motor skills have been proposed as underlying courses of handwriting difficulties. However, there is no evaluation tool currently available to assess these skills comprehensively and to serve as a sensitive measure. The purpose of this study was to validate the Computerized Perceptual Motor Skills Assessment (CPMSA), a newly developed evaluation tool for children in early elementary grades. Its test-retest reliability, concurrent validity, discriminant validity, and responsiveness were examined in 43 typically developing children and 26 children with handwriting difficulty. The CPMSA demonstrated excellent reliability across all subtests with intra-class correlation coefficients (ICCs)≥0.80. Significant moderate correlations between the domains of the CPMSA and corresponding gold standards including Beery VMI, the TVPS-3, and the eye-hand coordination subtest of the DTVP-2 demonstrated good concurrent validity. In addition, the CPMSA showed evidence of discriminant validity in samples of children with and without handwriting difficulty. This article provides evidence in support of the CPMSA. The CPMSA is a reliable, valid, and promising measure of visual perceptual motor skills for children in early elementary grades. Directions for future study and improvements to the assessment are discussed. Copyright © 2017. Published by Elsevier Ltd.

  7. The Brain Database: A Multimedia Neuroscience Database for Research and Teaching

    PubMed Central

    Wertheim, Steven L.

    1989-01-01

    The Brain Database is an information tool designed to aid in the integration of clinical and research results in neuroanatomy and regional biochemistry. It can handle a wide range of data types including natural images, 2 and 3-dimensional graphics, video, numeric data and text. It is organized around three main entities: structures, substances and processes. The database will support a wide variety of graphical interfaces. Two sample interfaces have been made. This tool is intended to serve as one component of a system that would allow neuroscientists and clinicians 1) to represent clinical and experimental data within a common framework 2) to compare results precisely between experiments and among laboratories, 3) to use computing tools as an aid in collaborative work and 4) to contribute to a shared and accessible body of knowledge about the nervous system.

  8. Development and training of a learning expert system in an autonomous mobile robot via simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spelt, P.F.; Lyness, E.; DeSaussure, G.

    1989-11-01

    The Center for Engineering Systems Advanced Research (CESAR) conducts basic research in the area of intelligent machines. Recently at CESAR a learning expert system was created to operate on board an autonomous robot working at a process control panel. The authors discuss two-computer simulation system used to create, evaluate and train this learning system. The simulation system has a graphics display of the current status of the process being simulated, and the same program which does the simulating also drives the actual control panel. Simulation results were validated on the actual robot. The speed and safety values of using amore » computerized simulator to train a learning computer, and future uses of the simulation system, are discussed.« less

  9. A Visual Tool for Computer Supported Learning: The Robot Motion Planning Example

    ERIC Educational Resources Information Center

    Elnagar, Ashraf; Lulu, Leena

    2007-01-01

    We introduce an effective computer aided learning visual tool (CALVT) to teach graph-based applications. We present the robot motion planning problem as an example of such applications. The proposed tool can be used to simulate and/or further to implement practical systems in different areas of computer science such as graphics, computational…

  10. Hydrologic data-verification management program plan

    USGS Publications Warehouse

    Alexander, C.W.

    1982-01-01

    Data verification refers to the performance of quality control on hydrologic data that have been retrieved from the field and are being prepared for dissemination to water-data users. Water-data users now have access to computerized data files containing unpublished, unverified hydrologic data. Therefore, it is necessary to develop techniques and systems whereby the computer can perform some data-verification functions before the data are stored in user-accessible files. Computerized data-verification routines can be developed for this purpose. A single, unified concept describing master data-verification program using multiple special-purpose subroutines, and a screen file containing verification criteria, can probably be adapted to any type and size of computer-processing system. Some traditional manual-verification procedures can be adapted for computerized verification, but new procedures can also be developed that would take advantage of the powerful statistical tools and data-handling procedures available to the computer. Prototype data-verification systems should be developed for all three data-processing environments as soon as possible. The WATSTORE system probably affords the greatest opportunity for long-range research and testing of new verification subroutines. (USGS)

  11. Interactive computerized learning program exposes veterinary students to challenging international animal-health problems.

    PubMed

    Conrad, Patricia A; Hird, Dave; Arzt, Jonathan; Hayes, Rick H; Magliano, Dave; Kasper, Janine; Morfin, Saul; Pinney, Stephen

    2007-01-01

    This article describes a computerized case-based CD-ROM (CD) on international animal health that was developed to give veterinary students an opportunity to "virtually" work alongside veterinarians and other veterinary students as they try to solve challenging disease problems relating to tuberculosis in South African wildlife, bovine abortion in Mexico, and neurologic disease in horses in Rapa Nui, Chile. Each of the three case modules presents, in a highly interactive format, a problem or mystery that must be solved by the learner. As well as acquiring information via video clips and text about the specific health problem, learners obtain information about the different countries, animal-management practices, diagnostic methods, related disease-control issues, economic factors, and the opinions of local experts. After assimilating this information, the learner must define the problem and formulate an action plan or make a recommendation or diagnosis. The computerized program invokes three principles of adult education: active learning, learner-centered education, and experiential learning. A medium that invokes these principles is a potentially efficient learning tool and template for developing other case-based problem-solving computerized programs. The program is accessible on the World Wide Web at . A broadband Internet connection is recommended, since the modules make extensive use of embedded video and audio clips. Information on how to obtain the CD is also provided.

  12. Internet MEMS design tools based on component technology

    NASA Astrophysics Data System (ADS)

    Brueck, Rainer; Schumer, Christian

    1999-03-01

    The micro electromechanical systems (MEMS) industry in Europe is characterized by small and medium sized enterprises specialized on products to solve problems in specific domains like medicine, automotive sensor technology, etc. In this field of business the technology driven design approach known from micro electronics is not appropriate. Instead each design problem aims at its own, specific technology to be used for the solution. The variety of technologies at hand, like Si-surface, Si-bulk, LIGA, laser, precision engineering requires a huge set of different design tools to be available. No single SME can afford to hold licenses for all these tools. This calls for a new and flexible way of designing, implementing and distributing design software. The Internet provides a flexible manner of offering software access along with methodologies of flexible licensing e.g. on a pay-per-use basis. New communication technologies like ADSL, TV cable of satellites as carriers promise to offer a bandwidth sufficient even for interactive tools with graphical interfaces in the near future. INTERLIDO is an experimental tool suite for process specification and layout verification for lithography based MEMS technologies to be accessed via the Internet. The first version provides a Java implementation even including a graphical editor for process specification. Currently, a new version is brought into operation that is based on JavaBeans component technology. JavaBeans offers the possibility to realize independent interactive design assistants, like a design rule checking assistants, a process consistency checking assistants, a technology definition assistants, a graphical editor assistants, etc. that may reside distributed over the Internet, communicating via Internet protocols. Each potential user thus is able to configure his own dedicated version of a design tool set dedicated to the requirements of the current problem to be solved.

  13. Simulated Breeding

    NASA Astrophysics Data System (ADS)

    Unemi, Tatsuo

    This chapter describes a basic framework of simulated breeding, a type of interactive evolutionary computing to breed artifacts, whose origin is Blind Watchmaker by Dawkins. These methods make it easy for humans to design a complex object adapted to his/her subjective criteria, just similarly to agricultural products we have been developing over thousands of years. Starting from randomly initialized genome, the solution candidates are improved through several generations with artificial selection. The graphical user interface helps the process of breeding with techniques of multifield user interface and partial breeding. The former improves the diversity of individuals that prevents being trapped at local optimum. The latter makes it possible for the user to fix features he/she already satisfied. These methods were examined through artistic applications by the author: SBART for graphics art and SBEAT for music. Combining with a direct genome editor and exportation to another graphical or musical tool on the computer, they can be powerful tools for artistic creation. These systems may contribute to the creation of a type of new culture.

  14. Big Data and Chemical Education

    ERIC Educational Resources Information Center

    Pence, Harry E.; Williams, Antony J.

    2016-01-01

    The amount of computerized information that organizations collect and process is growing so large that the term Big Data is commonly being used to describe the situation. Accordingly, Big Data is defined by a combination of the Volume, Variety, Velocity, and Veracity of the data being processed. Big Data tools are already having an impact in…

  15. Computerization: A Key to Humanization.

    ERIC Educational Resources Information Center

    Falzetta, John N.

    Computers can be valuable tools of humanization if educators use them to relate the curriculum to the students' lives and to make schools more desirable places in which to learn. Despite the facts that much of the content of both the country's generally accepted national goals and students' interests and problems is affective in nature, most…

  16. Automated Inspection And Precise Grinding Of Gears

    NASA Technical Reports Server (NTRS)

    Frint, Harold; Glasow, Warren

    1995-01-01

    Method of precise grinding of spiral bevel gears involves automated inspection of gear-tooth surfaces followed by adjustments of machine-tool settings to minimize differences between actual and nominal surfaces. Similar to method described in "Computerized Inspection of Gear-Tooth Surfaces" (LEW-15736). Yields gears of higher quality, with significant reduction in manufacturing and inspection time.

  17. Establishing Ongoing, Early Identification Programs for Mental Health Problems in Our Schools: A Feasibility Study

    ERIC Educational Resources Information Center

    Nemeroff, Robin; Levitt, Jessica Mass; Faul, Lisa; Wonpat-Borja, Ahtoy; Bufferd, Sara; Setterberg, Stephen; Jensen, Peter S.

    2008-01-01

    The study evaluates the feasibility and effectiveness of several mental health screening and assessment tools in schools. A computerized version of the Diagnostic Interview Schedule for Children-IV proved to be feasible bridging the gap between mental health providers and unmet need of children accompanying risks.

  18. What Is An Expert System? ERIC Digest.

    ERIC Educational Resources Information Center

    Boss, Richard W.

    This digest describes and defines the various components of an expert system, e.g., a computerized tool designed to enhance the quality and availability of knowledge required by decision makers. It is noted that expert systems differ from conventional applications software in the following areas: (1) the existence of the expert systems shell, or…

  19. The library as a reference tool: online catalogs

    USGS Publications Warehouse

    Stark, M.

    1991-01-01

    Online catalogs are computerized listings of materials in a particular library or group of libraries. General characteristics of online catalogs include ability for searching interactively and for locating descriptions of books, maps, and reports on regional or topical geology. Suggestions for searching, evaluating results, modifying searches, and limitations of searching are presented. -Author

  20. An Introduction to the Transition to Work Simulator.

    ERIC Educational Resources Information Center

    Conroy, William G., Jr.

    The transition to work simulator (TWS) was developed as a policy tool for education and manpower planning. It was designed in anticipation of the Education Amendments of 1976 and the Youth Employment and Demonstration Projects Act of 1977 to facilitate comprehensive planning. TWS is a computerized simulation model of the stream of important…

  1. Neuropsychological Construct Structure of a Brief Computerized Neuropsychological Battery: Windows Spaceflight Cognitive Assessment Tool (WinSCAT)

    DTIC Science & Technology

    2005-09-08

    active, or widespread skin conditions such as eczema, psoriasis or a bad sunburn, you will not be able to participate in the study. If you have a history...the following health conditions?" Flashbacks/ PTSD _Panic Attacks/Disorder _Schizophrenia _Anxiety/Depression _Substance Abuse _Bipolar Disorder/Manic

  2. New Tools for "New" History: Computers and the Teaching of Quantitative Historical Methods.

    ERIC Educational Resources Information Center

    Burton, Orville Vernon; Finnegan, Terence

    1989-01-01

    Explains the development of an instructional software package and accompanying workbook which teaches students to apply computerized statistical analysis to historical data, improving the study of social history. Concludes that the use of microcomputers and supercomputers to manipulate historical data enhances critical thinking skills and the use…

  3. Improvement of Word Problem Solving and Basic Mathematics Competencies in Students with Attention Deficit/Hyperactivity Disorder and Mathematical Learning Difficulties

    ERIC Educational Resources Information Center

    González-Castro, Paloma; Cueli, Marisol; Areces, Débora; Rodríguez, Celestino; Sideridis, Georgios

    2016-01-01

    Problem solving represents a salient deficit in students with mathematical learning difficulties (MLD) primarily caused by difficulties with informal and formal mathematical competencies. This study proposes a computerized intervention tool, the integrated dynamic representation (IDR), for enhancing the early learning of basic mathematical…

  4. Computer Grading As an Instructional Tool.

    ERIC Educational Resources Information Center

    Rottmann, Ray M.; Hudson, H. T.

    1983-01-01

    Describes computer grading system providing/storing scores and giving feedback to instructors on how students are performing on a day-to-day basis and how they are handling course concepts. Focuses on the hardware and software of this efficient computerized grading package, which can be used with classes of 250 students (or larger). (Author/JN)

  5. Positron emission tomography/computerized tomography in lung cancer

    PubMed Central

    Vural, Gulin Ucmak

    2014-01-01

    Positron emission tomography (PET) using 2-(18F)-flouro-2-deoxy-D-glucose (FDG) has emerged as a useful tool in the clinical work-up of lung cancer. This review article provides an overview of applications of PET in diagnosis, staging, treatment response evaluation, radiotherapy planning, recurrence assessment and prognostication of lung cancer. PMID:24914421

  6. Computerized Simulation in the Social Sciences: A Survey and Evaluation

    ERIC Educational Resources Information Center

    Garson, G. David

    2009-01-01

    After years at the periphery of the social sciences, simulation is now emerging as an important and widely used tool for understanding social phenomena. Through simulation, researchers can identify causal effects, specify critical parameter estimates, and clarify the state of the art with respect to what is understood about how processes evolve…

  7. A Thesaurus for Use in a Computer-Aided Abstracting Tool Kit.

    ERIC Educational Resources Information Center

    Craven, Timothy C.

    1993-01-01

    Discusses the use of thesauri in automatic indexing and describes the development of a prototype computerized abstractor's assistant. Topics addressed include TEXNET, a text network management system; the use of TEXNET for abstracting; the structure and use of a thesaurus for abstracting in TEXNET; and weighted terms. (Contains 26 references.)…

  8. End-user satisfaction of a patient education tool manual versus computer-generated tool.

    PubMed

    Tronni, C; Welebob, E

    1996-01-01

    This article reports a nonexperimental comparative study of end-user satisfaction before and after implementation of a vendor supplied computerized system (Micromedex, Inc) for providing up-to-date patient instructions regarding diseases, injuries, procedures, and medications. The purpose of this research was to measure the satisfaction of nurses who directly interact with a specific patient educational software application and to compare user satisfaction with manual versus computer generated materials. A computing satisfaction questionnaire that uses a scale of 1 to 5 (1 being the lowest) was used to measure end-user computing satisfaction in five constructs: content, accuracy, format, ease of use, and timeliness. Summary statistics were used to calculate mean ratings for each of the questionnaire's 12 items and for each of the five constructs. Mean differences between the ratings before and after implementation of the five constructs were significant by paired t test. Total user satisfaction improved with the computerized system, and the computer generated materials were given a higher rating than were the manual materials. Implications of these findings are discussed.

  9. Feasibility of Web-based Technology to Assess Adherence to Clinic Appointments in Youth with Sickle Cell Disease

    PubMed Central

    Modi, Avani C.; Crosby, Lori E.; Hines, Janelle; Drotar, Dennis; Mitchell, Monica J.

    2011-01-01

    Web-based tools to improve clinic attendance have been effectively used in pediatric conditions but have not been tested in pediatric sickle cell disease (SCD). The goal of this pilot study was to assess barriers to clinic attendance and the feasibility of a web-based assessment tool to promote problem-solving around clinic appointments. Study participants included 30 youth with SCD (M=11.7±3.5 years; 57% male; 60% HbSS; 20% HbSC; 17% HB+Thal) and their primary caregivers. Medical chart review indicated that 61% of participants attended at least two SCD clinic appointments in the past year. The primary barrier to clinic attendance was inability to take off from work/school (33%). Regarding feasibility and acceptability, the computerized program was well-received by patients and caregivers, with youth and caregivers reporting a high degree of usefulness and preference for computerized assessment. Results suggest that this innovative approach shows promise and should be tested on a larger sample of youth with SCD. PMID:22278205

  10. Graphical display of histopathology data from toxicology studies for drug discovery and development: An industry perspective.

    PubMed

    Brown, Alan P; Drew, Philip; Knight, Brian; Marc, Philippe; Troth, Sean; Wuersch, Kuno; Zandee, Joyce

    2016-12-01

    Histopathology data comprise a critical component of pharmaceutical toxicology studies and are typically presented as finding incidence counts and severity scores per organ, and tabulated on multiple pages which can be challenging for review and aggregation of results. However, the SEND (Standard for Exchange of Nonclinical Data) standard provides a means for collecting and managing histopathology data in a uniform fashion which can allow informatics systems to archive, display and analyze data in novel ways. Various software applications have become available to convert histopathology data into graphical displays for analyses. A subgroup of the FDA-PhUSE Nonclinical Working Group conducted intra-industry surveys regarding the use of graphical displays of histopathology data. Visual cues, use-cases, the value of cross-domain and cross-study visualizations, and limitations were topics for discussion in the context of the surveys. The subgroup came to the following conclusions. Graphical displays appear advantageous as a communication tool to both pathologists and non-pathologists, and provide an efficient means for communicating pathology findings to project teams. Graphics can support hypothesis-generation which could include cross-domain interactive visualizations and/-or aggregating large datasets from multiple studies to observe and/or display patterns and trends. Incorporation of the SEND standard will provide a platform by which visualization tools will be able to aggregate, select and display information from complex and disparate datasets. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Grasping Reality Through Illusion: Interactive Graphics Serving Science

    DTIC Science & Technology

    1988-03-01

    SIGGRAPH, or riding techniques to the enhancement of scientific computing. StarTours at Disneyland shows how stunningly far we ........ have come. We need...supercomputer References matching and steering tools. Such tools must be Bergman, L., Fuchs, H., Grant , E., Spach, S. [1986] universal and application

  12. A software tool for analyzing multichannel cochlear implant signals.

    PubMed

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  13. ARX - A Comprehensive Tool for Anonymizing Biomedical Data

    PubMed Central

    Prasser, Fabian; Kohlmayer, Florian; Lautenschläger, Ronald; Kuhn, Klaus A.

    2014-01-01

    Collaboration and data sharing have become core elements of biomedical research. Especially when sensitive data from distributed sources are linked, privacy threats have to be considered. Statistical disclosure control allows the protection of sensitive data by introducing fuzziness. Reduction of data quality, however, needs to be balanced against gains in protection. Therefore, tools are needed which provide a good overview of the anonymization process to those responsible for data sharing. These tools require graphical interfaces and the use of intuitive and replicable methods. In addition, extensive testing, documentation and openness to reviews by the community are important. Existing publicly available software is limited in functionality, and often active support is lacking. We present ARX, an anonymization tool that i) implements a wide variety of privacy methods in a highly efficient manner, ii) provides an intuitive cross-platform graphical interface, iii) offers a programming interface for integration into other software systems, and iv) is well documented and actively supported. PMID:25954407

  14. Food Web Designer: a flexible tool to visualize interaction networks.

    PubMed

    Sint, Daniela; Traugott, Michael

    Species are embedded in complex networks of ecological interactions and assessing these networks provides a powerful approach to understand what the consequences of these interactions are for ecosystem functioning and services. This is mandatory to develop and evaluate strategies for the management and control of pests. Graphical representations of networks can help recognize patterns that might be overlooked otherwise. However, there is a lack of software which allows visualizing these complex interaction networks. Food Web Designer is a stand-alone, highly flexible and user friendly software tool to quantitatively visualize trophic and other types of bipartite and tripartite interaction networks. It is offered free of charge for use on Microsoft Windows platforms. Food Web Designer is easy to use without the need to learn a specific syntax due to its graphical user interface. Up to three (trophic) levels can be connected using links cascading from or pointing towards the taxa within each level to illustrate top-down and bottom-up connections. Link width/strength and abundance of taxa can be quantified, allowing generating fully quantitative networks. Network datasets can be imported, saved for later adjustment and the interaction webs can be exported as pictures for graphical display in different file formats. We show how Food Web Designer can be used to draw predator-prey and host-parasitoid food webs, demonstrating that this software is a simple and straightforward tool to graphically display interaction networks for assessing pest control or any other type of interaction in both managed and natural ecosystems from an ecological network perspective.

  15. Graphics simulation and training aids for advanced teleoperation

    NASA Technical Reports Server (NTRS)

    Kim, Won S.; Schenker, Paul S.; Bejczy, Antal K.

    1993-01-01

    Graphics displays can be of significant aid in accomplishing a teleoperation task throughout all three phases of off-line task analysis and planning, operator training, and online operation. In the first phase, graphics displays provide substantial aid to investigate work cell layout, motion planning with collision detection and with possible redundancy resolution, and planning for camera views. In the second phase, graphics displays can serve as very useful tools for introductory training of operators before training them on actual hardware. In the third phase, graphics displays can be used for previewing planned motions and monitoring actual motions in any desired viewing angle, or, when communication time delay prevails, for providing predictive graphics overlay on the actual camera view of the remote site to show the non-time-delayed consequences of commanded motions in real time. This paper addresses potential space applications of graphics displays in all three operational phases of advanced teleoperation. Possible applications are illustrated with techniques developed and demonstrated in the Advanced Teleoperation Laboratory at JPL. The examples described include task analysis and planning of a simulated Solar Maximum Satellite Repair task, a novel force-reflecting teleoperation simulator for operator training, and preview and predictive displays for on-line operations.

  16. The design of an intelligent human-computer interface for the test, control and monitor system

    NASA Technical Reports Server (NTRS)

    Shoaff, William D.

    1988-01-01

    The graphical intelligence and assistance capabilities of a human-computer interface for the Test, Control, and Monitor System at Kennedy Space Center are explored. The report focuses on how a particular commercial off-the-shelf graphical software package, Data Views, can be used to produce tools that build widgets such as menus, text panels, graphs, icons, windows, and ultimately complete interfaces for monitoring data from an application; controlling an application by providing input data to it; and testing an application by both monitoring and controlling it. A complete set of tools for building interfaces is described in a manual for the TCMS toolkit. Simple tools create primitive widgets such as lines, rectangles and text strings. Intermediate level tools create pictographs from primitive widgets, and connect processes to either text strings or pictographs. Other tools create input objects; Data Views supports output objects directly, thus output objects are not considered. Finally, a set of utilities for executing, monitoring use, editing, and displaying the content of interfaces is included in the toolkit.

  17. Computer aided three-dimensional reconstruction and modeling of the pelvis, by using plastinated cross sections, as a powerful tool for morphological investigations.

    PubMed

    Sora, Mircea-Constantin; Jilavu, Radu; Matusz, Petru

    2012-10-01

    The aim of this study was to describe a method of developing a computerized model of the human female pelvis using plastinated slices. Computerized reconstruction of anatomical structures is becoming very useful for developing anatomical teaching, research modules and animations. Although databases consisting of serial sections derived from frozen cadaver material exist, plastination represents an alternative method for developing anatomical data useful for computerized reconstruction. A slice anatomy study, using plastinated transparent pelvis cross sections, was performed to obtain a 3D reconstruction. One female human pelvis used for this study, first plastinated as a block, then sliced into thin slices and in the end subjected to 3D computerized reconstruction using WinSURF modeling system (SURFdriver Software). To facilitate the understanding of the complex pelvic floor anatomy on sectional images obtained through MR imaging, and to make the representation more vivid, a female pelvis computer-aided 3D model was created. Qualitative observations revealed that the morphological features of the model were consistent with those displayed by typical cadaveric specimens. The quality of the reconstructed images appeared distinct, especially the spatial positions and complicated relationships of contiguous structures of the female pelvis. All reconstructed structures can be displayed in groups or as a whole and interactively rotated in 3D space. The utilization of plastinates for generating tissue sections is useful for 3D computerized modeling. The 3D model of the female pelvis presented in this paper provides a stereoscopic view to study the adjacent relationship and arrangement of respective pelvis sections. A better understanding of the pelvic floor anatomy is relevant to gynaecologists, radiologists, surgeons, urologists, physical therapists and all professionals who take care of women with pelvic floor dysfunction.

  18. TAE Plus: Transportable Applications Environment Plus tools for building graphic-oriented applications

    NASA Technical Reports Server (NTRS)

    Szczur, Martha R.

    1989-01-01

    The Transportable Applications Environment Plus (TAE Plus), developed by NASA's Goddard Space Flight Center, is a portable User Interface Management System (UIMS), which provides an intuitive WYSIWYG WorkBench for prototyping and designing an application's user interface, integrated with tools for efficiently implementing the designed user interface and effective management of the user interface during an application's active domain. During the development of TAE Plus, many design and implementation decisions were based on the state-of-the-art within graphics workstations, windowing system and object-oriented programming languages. Some of the problems and issues experienced during implementation are discussed. A description of the next development steps planned for TAE Plus is also given.

  19. Using CASE tools to write engineering specifications

    NASA Astrophysics Data System (ADS)

    Henry, James E.; Howard, Robert W.; Iveland, Scott T.

    1993-08-01

    There are always a wide variety of obstacles to writing and maintaining engineering documentation. To combat these problems, documentation generation can be linked to the process of engineering development. The same graphics and communication tools used for structured system analysis and design (SSA/SSD) also form the basis for the documentation. The goal is to build a living document, such that as an engineering design changes, the documentation will `automatically' revise. `Automatic' is qualified by the need to maintain textual descriptions associated with the SSA/SSD graphics, and the need to generate new documents. This paper describes a methodology and a computer aided system engineering toolset that enables a relatively seamless transition into document generation for the development engineering team.

  20. The computerized adaptive diagnostic test for major depressive disorder (CAD-MDD): a screening tool for depression.

    PubMed

    Gibbons, Robert D; Hooker, Giles; Finkelman, Matthew D; Weiss, David J; Pilkonis, Paul A; Frank, Ellen; Moore, Tara; Kupfer, David J

    2013-07-01

    To develop a computerized adaptive diagnostic screening tool for depression that decreases patient and clinician burden and increases sensitivity and specificity for clinician-based DSM-IV diagnosis of major depressive disorder (MDD). 656 individuals with and without minor and major depression were recruited from a psychiatric clinic and a community mental health center and through public announcements (controls without depression). The focus of the study was the development of the Computerized Adaptive Diagnostic Test for Major Depressive Disorder (CAD-MDD) diagnostic screening tool based on a decision-theoretical approach (random forests and decision trees). The item bank consisted of 88 depression scale items drawn from 73 depression measures. Sensitivity and specificity for predicting clinician-based Structured Clinical Interview for DSM-IV Axis I Disorders diagnoses of MDD were the primary outcomes. Diagnostic screening accuracy was then compared to that of the Patient Health Questionnaire-9 (PHQ-9). An average of 4 items per participant was required (maximum of 6 items). Overall sensitivity and specificity were 0.95 and 0.87, respectively. For the PHQ-9, sensitivity was 0.70 and specificity was 0.91. High sensitivity and reasonable specificity for a clinician-based DSM-IV diagnosis of depression can be obtained using an average of 4 adaptively administered self-report items in less than 1 minute. Relative to the currently used PHQ-9, the CAD-MDD dramatically increased sensitivity while maintaining similar specificity. As such, the CAD-MDD will identify more true positives (lower false-negative rate) than the PHQ-9 using half the number of items. Inexpensive (relative to clinical assessment), efficient, and accurate screening of depression in the settings of primary care, psychiatric epidemiology, molecular genetics, and global health are all direct applications of the current system. © Copyright 2013 Physicians Postgraduate Press, Inc.

  1. A quality assessment tool for markup-based clinical guidelines.

    PubMed

    Shalom, Erez; Shahar, Yuval; Taieb-Maimon, Meirav; Lunenfeld, Eitan

    2008-11-06

    We introduce a tool for quality assessment of procedural and declarative knowledge. We developed this tool for evaluating the specification of mark-up-based clinical GLs. Using this graphical tool, the expert physician and knowledge engineer collaborate to perform scoring, using pre-defined scoring scale, each of the knowledge roles of the mark-ups, comparing it to a gold standard. The tool enables scoring the mark-ups simultaneously at different sites by different users at different locations.

  2. Interactive voxel graphics in virtual reality

    NASA Astrophysics Data System (ADS)

    Brody, Bill; Chappell, Glenn G.; Hartman, Chris

    2002-06-01

    Interactive voxel graphics in virtual reality poses significant research challenges in terms of interface, file I/O, and real-time algorithms. Voxel graphics is not so new, as it is the focus of a good deal of scientific visualization. Interactive voxel creation and manipulation is a more innovative concept. Scientists are understandably reluctant to manipulate data. They collect or model data. A scientific analogy to interactive graphics is the generation of initial conditions for some model. It is used as a method to test those models. We, however, are in the business of creating new data in the form of graphical imagery. In our endeavor, science is a tool and not an end. Nevertheless, there is a whole class of interactions and associated data generation scenarios that are natural to our way of working and that are also appropriate to scientific inquiry. Annotation by sketching or painting to point to and distinguish interesting and important information is very significant for science as well as art. Annotation in 3D is difficult without a good 3D interface. Interactive graphics in virtual reality is an appropriate approach to this problem.

  3. Gene Graphics: a genomic neighborhood data visualization web application.

    PubMed

    Harrison, Katherine J; Crécy-Lagard, Valérie de; Zallot, Rémi

    2018-04-15

    The examination of gene neighborhood is an integral part of comparative genomics but no tools to produce publication quality graphics of gene clusters are available. Gene Graphics is a straightforward web application for creating such visuals. Supported inputs include National Center for Biotechnology Information gene and protein identifiers with automatic fetching of neighboring information, GenBank files and data extracted from the SEED database. Gene representations can be customized for many parameters including gene and genome names, colors and sizes. Gene attributes can be copied and pasted for rapid and user-friendly customization of homologous genes between species. In addition to Portable Network Graphics and Scalable Vector Graphics, produced representations can be exported as Tagged Image File Format or Encapsulated PostScript, formats that are standard for publication. Hands-on tutorials with real life examples inspired from publications are available for training. Gene Graphics is freely available at https://katlabs.cc/genegraphics/ and source code is hosted at https://github.com/katlabs/genegraphics. katherinejh@ufl.edu or remizallot@ufl.edu. Supplementary data are available at Bioinformatics online.

  4. Interactive cutting path analysis programs

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.; Williams, D. S.; Colley, S. R.

    1975-01-01

    The operation of numerically controlled machine tools is interactively simulated. Four programs were developed to graphically display the cutting paths for a Monarch lathe, Cintimatic mill, Strippit sheet metal punch, and the wiring path for a Standard wire wrap machine. These programs are run on a IMLAC PDS-ID graphic display system under the DOS-3 disk operating system. The cutting path analysis programs accept input via both paper tape and disk file.

  5. Western aeronautical test range real-time graphics software package MAGIC

    NASA Technical Reports Server (NTRS)

    Malone, Jacqueline C.; Moore, Archie L.

    1988-01-01

    The master graphics interactive console (MAGIC) software package used on the Western Aeronautical Test Range (WATR) of the NASA Ames Research Center is described. MAGIC is a resident real-time research tool available to flight researchers-scientists in the NASA mission control centers of the WATR at the Dryden Flight Research Facility at Edwards, California. The hardware configuration and capabilities of the real-time software package are also discussed.

  6. Viewpoints: A High-Performance High-Dimensional Exploratory Data Analysis Tool

    NASA Astrophysics Data System (ADS)

    Gazis, P. R.; Levit, C.; Way, M. J.

    2010-12-01

    Scientific data sets continue to increase in both size and complexity. In the past, dedicated graphics systems at supercomputing centers were required to visualize large data sets, but as the price of commodity graphics hardware has dropped and its capability has increased, it is now possible, in principle, to view large complex data sets on a single workstation. To do this in practice, an investigator will need software that is written to take advantage of the relevant graphics hardware. The Viewpoints visualization package described herein is an example of such software. Viewpoints is an interactive tool for exploratory visual analysis of large high-dimensional (multivariate) data. It leverages the capabilities of modern graphics boards (GPUs) to run on a single workstation or laptop. Viewpoints is minimalist: it attempts to do a small set of useful things very well (or at least very quickly) in comparison with similar packages today. Its basic feature set includes linked scatter plots with brushing, dynamic histograms, normalization, and outlier detection/removal. Viewpoints was originally designed for astrophysicists, but it has since been used in a variety of fields that range from astronomy, quantum chemistry, fluid dynamics, machine learning, bioinformatics, and finance to information technology server log mining. In this article, we describe the Viewpoints package and show examples of its usage.

  7. Femoral articular shape and geometry. A three-dimensional computerized analysis of the knee.

    PubMed

    Siu, D; Rudan, J; Wevers, H W; Griffiths, P

    1996-02-01

    An average, three-dimensional anatomic shape and geometry of the distal femur were generated from x-ray computed tomography data of five fresh asymptomatic cadaver knees using AutoCAD (AutoDesk, Sausalito, CA), a computer-aided design and drafting software. Each femur model was graphically repositioned to a standardized orientation using a series of alignment templates and scaled to a nominal size of 85 mm in mediolateral and 73 mm in anteroposterior dimensions. An average generic shape of the distal femur was synthesized by combining these pseudosolid models and reslicing the composite structure at different elevations using clipping and smoothing techniques in interactive computer graphics. The resulting distal femoral geometry was imported into a computer-aided manufacturing system, and anatomic prototypes of the distal femur were produced. Quantitative geometric analyses of the generic femur in the coronal and transverse planes revealed definite condylar camber (3 degrees-6 degrees) and toe-in (8 degrees-10 degrees) with an oblique patellofemoral groove (15 degrees) with respect to the mechanical axis of the femur. In the sagittal plane, each condyle could be approximated by three concatenated circular arcs (anterior, distal, and posterior) with slope continuity and a single arc for the patellofemoral groove. The results of this study may have important implications in future femoral prosthesis design and clinical applications.

  8. NASTRAN analysis of Tokamak vacuum vessel using interactive graphics

    NASA Technical Reports Server (NTRS)

    Miller, A.; Badrian, M.

    1978-01-01

    Isoparametric quadrilateral and triangular elements were used to represent the vacuum vessel shell structure. For toroidally symmetric loadings, MPCs were employed across model boundaries and rigid format 24 was invoked. Nonsymmetric loadings required the use of the cyclic symmetry analysis available with rigid format 49. NASTRAN served as an important analysis tool in the Tokamak design effort by providing a reliable means for assessing structural integrity. Interactive graphics were employed in the finite element model generation and in the post-processing of results. It was felt that model generation and checkout with interactive graphics reduced the modelling effort and debugging man-hours significantly.

  9. The Traffic Management Advisor

    NASA Technical Reports Server (NTRS)

    Nedell, William; Erzberger, Heinz; Neuman, Frank

    1990-01-01

    The traffic management advisor (TMA) is comprised of algorithms, a graphical interface, and interactive tools for controlling the flow of air traffic into the terminal area. The primary algorithm incorporated in it is a real-time scheduler which generates efficient landing sequences and landing times for arrivals within about 200 n.m. from touchdown. A unique feature of the TMA is its graphical interface that allows the traffic manager to modify the computer-generated schedules for specific aircraft while allowing the automatic scheduler to continue generating schedules for all other aircraft. The graphical interface also provides convenient methods for monitoring the traffic flow and changing scheduling parameters during real-time operation.

  10. Software engineering capability for Ada (GRASP/Ada Tool)

    NASA Technical Reports Server (NTRS)

    Cross, James H., II

    1995-01-01

    The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped a new algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis has been on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada Source code. A new Motif compliant graphical user interface has been developed for the GRASP/Ada prototype.

  11. User's manual for EZPLOT version 5.5: A FORTRAN program for 2-dimensional graphic display of data

    NASA Technical Reports Server (NTRS)

    Garbinski, Charles; Redin, Paul C.; Budd, Gerald D.

    1988-01-01

    EZPLOT is a computer applications program that converts data resident on a file into a plot displayed on the screen of a graphics terminal. This program generates either time history or x-y plots in response to commands entered interactively from a terminal keyboard. Plot parameters consist of a single independent parameter and from one to eight dependent parameters. Various line patterns, symbol shapes, axis scales, text labels, and data modification techniques are available. This user's manual describes EZPLOT as it is implemented on the Ames Research Center, Dryden Research Facility ELXSI computer using DI-3000 graphics software tools.

  12. Graphic Server: A real time system for displaying and monitoring telemetry data of several satellites

    NASA Technical Reports Server (NTRS)

    Douard, Stephane

    1994-01-01

    Known as a Graphic Server, the system presented was designed for the control ground segment of the Telecom 2 satellites. It is a tool used to dynamically display telemetry data within graphic pages, also known as views. The views are created off-line through various utilities and then, on the operator's request, displayed and animated in real time as data is received. The system was designed as an independent component, and is installed in different Telecom 2 operational control centers. It enables operators to monitor changes in the platform and satellite payloads in real time. It has been in operation since December 1991.

  13. Software for Data Analysis with Graphical Models

    NASA Technical Reports Server (NTRS)

    Buntine, Wray L.; Roy, H. Scott

    1994-01-01

    Probabilistic graphical models are being used widely in artificial intelligence and statistics, for instance, in diagnosis and expert systems, as a framework for representing and reasoning with probabilities and independencies. They come with corresponding algorithms for performing statistical inference. This offers a unifying framework for prototyping and/or generating data analysis algorithms from graphical specifications. This paper illustrates the framework with an example and then presents some basic techniques for the task: problem decomposition and the calculation of exact Bayes factors. Other tools already developed, such as automatic differentiation, Gibbs sampling, and use of the EM algorithm, make this a broad basis for the generation of data analysis software.

  14. Human Factors Evaluation of Advanced Electric Power Grid Visualization Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.; Dauenhauer, Peter M.; Wierks, Tamara G.

    This report describes initial human factors evaluation of four visualization tools (Graphical Contingency Analysis, Force Directed Graphs, Phasor State Estimator and Mode Meter/ Mode Shapes) developed by PNNL, and proposed test plans that may be implemented to evaluate their utility in scenario-based experiments.

  15. The Python Spectral Analysis Tool (PySAT) for Powerful, Flexible, and Easy Preprocessing and Machine Learning with Point Spectral Data

    NASA Astrophysics Data System (ADS)

    Anderson, R. B.; Finch, N.; Clegg, S. M.; Graff, T.; Morris, R. V.; Laura, J.

    2018-04-01

    The PySAT point spectra tool provides a flexible graphical interface, enabling scientists to apply a wide variety of preprocessing and machine learning methods to point spectral data, with an emphasis on multivariate regression.

  16. RAFCON: A Graphical Tool for Engineering Complex, Robotic Tasks

    DTIC Science & Technology

    2016-10-09

    Robotic tasks are becoming increasingly complex, and with this also the robotic systems. This requires new tools to manage this complexity and to...execution of robotic tasks, called RAFCON. These tasks are described in hierarchical state machines supporting concurrency. A formal notation of this concept

  17. WebMeV | Informatics Technology for Cancer Research (ITCR)

    Cancer.gov

    Web MeV (Multiple-experiment Viewer) is a web/cloud-based tool for genomic data analysis. Web MeV is being built to meet the challenge of exploring large public genomic data set with intuitive graphical interface providing access to state-of-the-art analytical tools.

  18. Micro-based fact collection tool user's manual

    NASA Technical Reports Server (NTRS)

    Mayer, Richard

    1988-01-01

    A procedure designed for use by an analyst to assist in the collection and organization of data gathered during the interview processes associated with system analysis and modeling task is described. The basic concept behind the development of this tool is that during the interview process an analyst is presented with assertions of facts by the domain expert. The analyst also makes observations of the domain. These facts need to be collected and preserved in such a way as to allow them to serve as the basis for a number of decision making processes throughout the system development process. This tool can be thought of as a computerization of the analysts's notebook.

  19. Improving designer productivity. [artificial intelligence

    NASA Technical Reports Server (NTRS)

    Hill, Gary C.

    1992-01-01

    Designer and design team productivity improves with skill, experience, and the tools available. The design process involves numerous trials and errors, analyses, refinements, and addition of details. Computerized tools have greatly speeded the analysis, and now new theories and methods, emerging under the label Artificial Intelligence (AI), are being used to automate skill and experience. These tools improve designer productivity by capturing experience, emulating recognized skillful designers, and making the essence of complex programs easier to grasp. This paper outlines the aircraft design process in today's technology and business climate, presenting some of the challenges ahead and some of the promising AI methods for meeting these challenges.

  20. InteGO2: a web tool for measuring and visualizing gene semantic similarities using Gene Ontology.

    PubMed

    Peng, Jiajie; Li, Hongxiang; Liu, Yongzhuang; Juan, Liran; Jiang, Qinghua; Wang, Yadong; Chen, Jin

    2016-08-31

    The Gene Ontology (GO) has been used in high-throughput omics research as a major bioinformatics resource. The hierarchical structure of GO provides users a convenient platform for biological information abstraction and hypothesis testing. Computational methods have been developed to identify functionally similar genes. However, none of the existing measurements take into account all the rich information in GO. Similarly, using these existing methods, web-based applications have been constructed to compute gene functional similarities, and to provide pure text-based outputs. Without a graphical visualization interface, it is difficult for result interpretation. We present InteGO2, a web tool that allows researchers to calculate the GO-based gene semantic similarities using seven widely used GO-based similarity measurements. Also, we provide an integrative measurement that synergistically integrates all the individual measurements to improve the overall performance. Using HTML5 and cytoscape.js, we provide a graphical interface in InteGO2 to visualize the resulting gene functional association networks. InteGO2 is an easy-to-use HTML5 based web tool. With it, researchers can measure gene or gene product functional similarity conveniently, and visualize the network of functional interactions in a graphical interface. InteGO2 can be accessed via http://mlg.hit.edu.cn:8089/ .

  1. GPU-BSM: A GPU-Based Tool to Map Bisulfite-Treated Reads

    PubMed Central

    Manconi, Andrea; Orro, Alessandro; Manca, Emanuele; Armano, Giuliano; Milanesi, Luciano

    2014-01-01

    Cytosine DNA methylation is an epigenetic mark implicated in several biological processes. Bisulfite treatment of DNA is acknowledged as the gold standard technique to study methylation. This technique introduces changes in the genomic DNA by converting cytosines to uracils while 5-methylcytosines remain nonreactive. During PCR amplification 5-methylcytosines are amplified as cytosine, whereas uracils and thymines as thymine. To detect the methylation levels, reads treated with the bisulfite must be aligned against a reference genome. Mapping these reads to a reference genome represents a significant computational challenge mainly due to the increased search space and the loss of information introduced by the treatment. To deal with this computational challenge we devised GPU-BSM, a tool based on modern Graphics Processing Units. Graphics Processing Units are hardware accelerators that are increasingly being used successfully to accelerate general-purpose scientific applications. GPU-BSM is a tool able to map bisulfite-treated reads from whole genome bisulfite sequencing and reduced representation bisulfite sequencing, and to estimate methylation levels, with the goal of detecting methylation. Due to the massive parallelization obtained by exploiting graphics cards, GPU-BSM aligns bisulfite-treated reads faster than other cutting-edge solutions, while outperforming most of them in terms of unique mapped reads. PMID:24842718

  2. The X-windows interactive navigation data editor

    NASA Technical Reports Server (NTRS)

    Rinker, G. C.

    1992-01-01

    A new computer program called the X-Windows Interactive Data Editor (XIDE) was developed and demonstrated as a prototype application for editing radio metric data in the orbit-determination process. The program runs on a variety of workstations and employs pull-down menus and graphical displays, which allow users to easily inspect and edit radio metric data in the orbit data files received from the Deep Space Network (DSN). The XIDE program is based on the Open Software Foundation OSF/Motif Graphical User Interface (GUI) and has proven to be an efficient tool for editing radio metric data in the navigation operations environment. It was adopted by the Magellan Navigation Team as their primary data-editing tool. Because the software was designed from the beginning to be portable, the prototype was successfully moved to new workstation environments. It was also itegrated into the design of the next-generation software tool for DSN multimission navigation interactive launch support.

  3. Microarray Я US: a user-friendly graphical interface to Bioconductor tools that enables accurate microarray data analysis and expedites comprehensive functional analysis of microarray results.

    PubMed

    Dai, Yilin; Guo, Ling; Li, Meng; Chen, Yi-Bu

    2012-06-08

    Microarray data analysis presents a significant challenge to researchers who are unable to use the powerful Bioconductor and its numerous tools due to their lack of knowledge of R language. Among the few existing software programs that offer a graphic user interface to Bioconductor packages, none have implemented a comprehensive strategy to address the accuracy and reliability issue of microarray data analysis due to the well known probe design problems associated with many widely used microarray chips. There is also a lack of tools that would expedite the functional analysis of microarray results. We present Microarray Я US, an R-based graphical user interface that implements over a dozen popular Bioconductor packages to offer researchers a streamlined workflow for routine differential microarray expression data analysis without the need to learn R language. In order to enable a more accurate analysis and interpretation of microarray data, we incorporated the latest custom probe re-definition and re-annotation for Affymetrix and Illumina chips. A versatile microarray results output utility tool was also implemented for easy and fast generation of input files for over 20 of the most widely used functional analysis software programs. Coupled with a well-designed user interface, Microarray Я US leverages cutting edge Bioconductor packages for researchers with no knowledge in R language. It also enables a more reliable and accurate microarray data analysis and expedites downstream functional analysis of microarray results.

  4. SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    EMAM, M; Eldib, A; Lin, M

    2014-06-01

    Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systemsmore » (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.« less

  5. Development of the Veritas plot and its application in cardiac surgery: an evidence-synthesis graphic tool for the clinician to assess multiple meta-analyses reporting on a common outcome.

    PubMed

    Panesar, Sukhmeet S; Rao, Christopher; Vecht, Joshua A; Mirza, Saqeb B; Netuveli, Gopalakrishnan; Morris, Richard; Rosenthal, Joe; Darzi, Ara; Athanasiou, Thanos

    2009-10-01

    Meta-analyses may be prone to generating misleading results because of a paucity of experimental studies (especially in surgery); publication bias; and heterogeneity in study design, intervention and the patient population of included studies. When investigating a specific clinical or scientific question on which several relevant meta-analyses may have been published, value judgments must be applied to determine which analysis represents the most robust evidence. These value judgments should be specifically acknowledged. We designed the Veritas plot to explicitly explore important elements of quality and to facilitate decision-making by highlighting specific areas in which meta-analyses are found to be deficient. Furthermore, as a graphic tool, it may be more intuitive than when similar data are presented in a tabular or text format. The Veritas plot is an adaption of the radar plot, a graphic tool for the description of multiattribute data. Key elements of meta-analytical quality such as heterogeneity, publication bias and study design are assessed. Existing qualitative methods such as the Assessment of Multiple Systematic Reviews (AMSTAR) tool have been incorporated in addition to important considerations when interpreting surgical meta-analyses such as the year of publication and population characteristics. To demonstrate the potential of the Veritas plot to inform clinical practice, we apply the Veritas plot to the meta-analytical literature comparing the incidence of 30-day stroke in off-pump coronary artery bypass surgery and conventional coronary artery bypass surgery. We demonstrate that a visually-stimulating and practical evidence-synthesis tool can direct the clinician and scientist to a particular meta-analytical study to inform clinical practice. The Veritas plot is also cumulative and allowed us to assess the quality of evidence over time. We have presented a practical graphic application for scientists and clinicians to identify and interpret variability in meta-analyses. Although further validation of the Veritas plot is required, it may have the potential to contribute to the implementation of evidence-based practice.

  6. Prediction of ball and roller bearing thermal and kinematic performance by computer analysis

    NASA Technical Reports Server (NTRS)

    Pirvics, J.; Kleckner, R. J.

    1983-01-01

    Characteristics of good computerized analysis software are suggested. These general remarks and an overview of representative software precede a more detailed discussion of load support system analysis program structure. Particular attention is directed at a recent cylindrical roller bearing analysis as an example of the available design tools. Selected software modules are then examined to reveal the detail inherent in contemporary analysis. This leads to a brief section on current design computation which seeks to suggest when and why computerized analysis is warranted. An example concludes the argument offered for such design methodology. Finally, remarks are made concerning needs for model development to address effects which are now considered to be secondary but are anticipated to emerge to primary status in the near future.

  7. Quantification of osteolytic bone lesions in a preclinical rat trial

    NASA Astrophysics Data System (ADS)

    Fränzle, Andrea; Bretschi, Maren; Bäuerle, Tobias; Giske, Kristina; Hillengass, Jens; Bendl, Rolf

    2013-10-01

    In breast cancer, most of the patients who died, have developed bone metastasis as disease progression. Bone metastases in case of breast cancer are mainly bone destructive (osteolytic). To understand pathogenesis and to analyse response to different treatments, animal models, in our case rats, are examined. For assessment of treatment response to bone remodelling therapies exact segmentations of osteolytic lesions are needed. Manual segmentations are not only time-consuming but lack in reproducibility. Computerized segmentation tools are essential. In this paper we present an approach for the computerized quantification of osteolytic lesion volumes using a comparison to a healthy reference model. The presented qualitative and quantitative evaluation of the reconstructed bone volumes show, that the automatically segmented lesion volumes complete missing bone in a reasonable way.

  8. Advancing satellite operations with intelligent graphical monitoring systems

    NASA Technical Reports Server (NTRS)

    Hughes, Peter M.; Shirah, Gregory W.; Luczak, Edward C.

    1993-01-01

    For nearly twenty-five years, spacecraft missions have been operated in essentially the same manner: human operators monitor displays filled with alphanumeric text watching for limit violations or other indicators that signal a problem. The task is performed predominately by humans. Only in recent years have graphical user interfaces and expert systems been accepted within the control center environment to help reduce operator workloads. Unfortunately, the development of these systems is often time consuming and costly. At the NASA Goddard Space Flight Center (GSFC), a new domain specific expert system development tool called the Generic Spacecraft Analyst Assistant (GenSAA) has been developed. Through the use of a highly graphical user interface and point-and-click operation, GenSAA facilitates the rapid, 'programming-free' construction of intelligent graphical monitoring systems to serve as real-time, fault-isolation assistants for spacecraft analysts. Although specifically developed to support real-time satellite monitoring, GenSAA can support the development of intelligent graphical monitoring systems in a variety of space and commercial applications.

  9. The Basic Organizing/Optimizing Training Scheduler (BOOTS): User's Guide. Technical Report 151.

    ERIC Educational Resources Information Center

    Church, Richard L.; Keeler, F. Laurence

    This report provides the step-by-step instructions required for using the Navy's Basic Organizing/Optimizing Training Scheduler (BOOTS) system. BOOTS is a computerized tool designed to aid in the creation of master training schedules for each Navy recruit training command. The system is defined in terms of three major functions: (1) data file…

  10. Comprehensive Achievement Monitoring in the Sequoia Union High School District. Symposium, California Mathematics Council Northern Section.

    ERIC Educational Resources Information Center

    Easter, John; And Others

    A description is provided of comprehensive Achievement Monitoring (CAM), a tool which enables classroom teachers to function as researchers and evaluators. Part I reviews the CAM philosophy and the section following discusses computerized feedback in CAM operations. The final two portions of the report describes the use of CAM in mathematics…

  11. Clinical Use of the Pediatric Attention Disorders Diagnostic Screener for Children at Risk for Attention Deficit Hyperactivity Disorder: Case Illustrations

    ERIC Educational Resources Information Center

    Keiser, Ashley; Reddy, Linda

    2013-01-01

    The Pediatric Attention Disorders Diagnostic Screener is a multidimensional, computerized screening tool designed to assess attention and global aspects of executive functioning in children at risk for attention disorders. The screener consists of a semi-structured diagnostic interview, brief parent and teacher rating scales, 3 computer-based…

  12. SCANIT: centralized digitizing of forest resource maps or photographs

    Treesearch

    Elliot L. Amidon; E. Joyce Dye

    1981-01-01

    Spatial data on wildland resource maps and aerial photographs can be analyzed by computer after digitizing. SCANIT is a computerized system for encoding such data in digital form. The system, consisting of a collection of computer programs and subroutines, provides a powerful and versatile tool for a variety of resource analyses. SCANIT also may be converted easily to...

  13. CAM Highlights (FY 80)

    DTIC Science & Technology

    1980-10-01

    industrialized nations in almost every manufacturing market place. Many foreign nation’s manu- facturing advancements have resulted from...towards planning a computerized data storage and retrieval system based on Group Technology (GT) principles . The data storage and re- trieval...several computer languages available on the market to program numerically controlled machine tools. However, there was a need for a docu- ment showing

  14. A Computer Program You Can Use: Edging and Trimmer Trainer

    Treesearch

    Philip A. Araman; D. Earl Kline; Matthew F. Winn

    1996-01-01

    We present a computerized training tool designed to help hardwood sawmill edger and trim saw operators improve their processing performance. It can also be used by managers to understand the affects of processing decisions such as limiting wane beyond standard grading rule restrictions. The program helps users understand the relationships between lumber grade, surface...

  15. Mapping individual logical processes in information searching

    NASA Technical Reports Server (NTRS)

    Smetana, F. O.

    1974-01-01

    An interactive dialog with a computerized information collection was recorded and plotted in the form of a flow chart. The process permits one to identify the logical processes employed in considerable detail and is therefore suggested as a tool for measuring individual thought processes in a variety of situations. A sample of an actual test case is given.

  16. The P.E.A.C.E. Pack: A Computerized Online Assessment of School Bullying

    ERIC Educational Resources Information Center

    Slee, Phillip T.; Mohyla, Jury

    2014-01-01

    School bullying is an international problem with harmful outcomes for those involved. This study describes the design and field testing of an innovative computer-based social learning tool for assessing student perceptions of bullying developed for an Australian intervention program called the P.E.A.C.E. Pack. Students rate their peer group…

  17. Design of automation tools for management of descent traffic

    NASA Technical Reports Server (NTRS)

    Erzberger, Heinz; Nedell, William

    1988-01-01

    The design of an automated air traffic control system based on a hierarchy of advisory tools for controllers is described. Compatibility of the tools with the human controller, a key objective of the design, is achieved by a judicious selection of tasks to be automated and careful attention to the design of the controller system interface. The design comprises three interconnected subsystems referred to as the Traffic Management Advisor, the Descent Advisor, and the Final Approach Spacing Tool. Each of these subsystems provides a collection of tools for specific controller positions and tasks. This paper focuses primarily on the Descent Advisor which provides automation tools for managing descent traffic. The algorithms, automation modes, and graphical interfaces incorporated in the design are described. Information generated by the Descent Advisor tools is integrated into a plan view traffic display consisting of a high-resolution color monitor. Estimated arrival times of aircraft are presented graphically on a time line, which is also used interactively in combination with a mouse input device to select and schedule arrival times. Other graphical markers indicate the location of the fuel-optimum top-of-descent point and the predicted separation distances of aircraft at a designated time-control point. Computer generated advisories provide speed and descent clearances which the controller can issue to aircraft to help them arrive at the feeder gate at the scheduled times or with specified separation distances. Two types of horizontal guidance modes, selectable by the controller, provide markers for managing the horizontal flightpaths of aircraft under various conditions. The entire system consisting of descent advisor algorithm, a library of aircraft performance models, national airspace system data bases, and interactive display software has been implemented on a workstation made by Sun Microsystems, Inc. It is planned to use this configuration in operational evaluations at an en route center.

  18. More than words: Using visual graphics for community-based health research.

    PubMed

    Morton Ninomiya, Melody E

    2017-04-20

    With increased attention to knowledge translation and community engagement in the applied health research field, many researchers aim to find effective ways of engaging health policy and decision makers and community stakeholders. While visual graphics such as graphs, charts, figures and photographs are common in scientific research dissemination, they are less common as a communication tool in research. In this commentary, I illustrate how and why visual graphics were created and used to facilitate dialogue and communication throughout all phases of a community-based health research study with a rural Indigenous community, advancing community engagement and knowledge utilization of a research study. I suggest that it is essential that researchers consider the use of visual graphics to accurately communicate and translate important health research concepts and content in accessible forms for diverse research stakeholders and target audiences.

  19. Using MATLAB software with Tomcat server and Java platform for remote image analysis in pathology.

    PubMed

    Markiewicz, Tomasz

    2011-03-30

    The Matlab software is a one of the most advanced development tool for application in engineering practice. From our point of view the most important is the image processing toolbox, offering many built-in functions, including mathematical morphology, and implementation of a many artificial neural networks as AI. It is very popular platform for creation of the specialized program for image analysis, also in pathology. Based on the latest version of Matlab Builder Java toolbox, it is possible to create the software, serving as a remote system for image analysis in pathology via internet communication. The internet platform can be realized based on Java Servlet Pages with Tomcat server as servlet container. In presented software implementation we propose remote image analysis realized by Matlab algorithms. These algorithms can be compiled to executable jar file with the help of Matlab Builder Java toolbox. The Matlab function must be declared with the set of input data, output structure with numerical results and Matlab web figure. Any function prepared in that manner can be used as a Java function in Java Servlet Pages (JSP). The graphical user interface providing the input data and displaying the results (also in graphical form) must be implemented in JSP. Additionally the data storage to database can be implemented within algorithm written in Matlab with the help of Matlab Database Toolbox directly with the image processing. The complete JSP page can be run by Tomcat server. The proposed tool for remote image analysis was tested on the Computerized Analysis of Medical Images (CAMI) software developed by author. The user provides image and case information (diagnosis, staining, image parameter etc.). When analysis is initialized, input data with image are sent to servlet on Tomcat. When analysis is done, client obtains the graphical results as an image with marked recognized cells and also the quantitative output. Additionally, the results are stored in a server database. The internet platform was tested on PC Intel Core2 Duo T9600 2.8 GHz 4 GB RAM server with 768x576 pixel size, 1.28 Mb tiff format images reffering to meningioma tumour (x400, Ki-67/MIB-1). The time consumption was as following: at analysis by CAMI, locally on a server - 3.5 seconds, at remote analysis - 26 seconds, from which 22 seconds were used for data transfer via internet connection. At jpg format image (102 Kb) the consumption time was reduced to 14 seconds. The results have confirmed that designed remote platform can be useful for pathology image analysis. The time consumption is depended mainly on the image size and speed of the internet connections. The presented implementation can be used for many types of analysis at different staining, tissue, morphometry approaches, etc. The significant problem is the implementation of the JSP page in the multithread form, that can be used parallelly by many users. The presented platform for image analysis in pathology can be especially useful for small laboratory without its own image analysis system.

  20. Using MATLAB software with Tomcat server and Java platform for remote image analysis in pathology

    PubMed Central

    2011-01-01

    Background The Matlab software is a one of the most advanced development tool for application in engineering practice. From our point of view the most important is the image processing toolbox, offering many built-in functions, including mathematical morphology, and implementation of a many artificial neural networks as AI. It is very popular platform for creation of the specialized program for image analysis, also in pathology. Based on the latest version of Matlab Builder Java toolbox, it is possible to create the software, serving as a remote system for image analysis in pathology via internet communication. The internet platform can be realized based on Java Servlet Pages with Tomcat server as servlet container. Methods In presented software implementation we propose remote image analysis realized by Matlab algorithms. These algorithms can be compiled to executable jar file with the help of Matlab Builder Java toolbox. The Matlab function must be declared with the set of input data, output structure with numerical results and Matlab web figure. Any function prepared in that manner can be used as a Java function in Java Servlet Pages (JSP). The graphical user interface providing the input data and displaying the results (also in graphical form) must be implemented in JSP. Additionally the data storage to database can be implemented within algorithm written in Matlab with the help of Matlab Database Toolbox directly with the image processing. The complete JSP page can be run by Tomcat server. Results The proposed tool for remote image analysis was tested on the Computerized Analysis of Medical Images (CAMI) software developed by author. The user provides image and case information (diagnosis, staining, image parameter etc.). When analysis is initialized, input data with image are sent to servlet on Tomcat. When analysis is done, client obtains the graphical results as an image with marked recognized cells and also the quantitative output. Additionally, the results are stored in a server database. The internet platform was tested on PC Intel Core2 Duo T9600 2.8GHz 4GB RAM server with 768x576 pixel size, 1.28Mb tiff format images reffering to meningioma tumour (x400, Ki-67/MIB-1). The time consumption was as following: at analysis by CAMI, locally on a server – 3.5 seconds, at remote analysis – 26 seconds, from which 22 seconds were used for data transfer via internet connection. At jpg format image (102 Kb) the consumption time was reduced to 14 seconds. Conclusions The results have confirmed that designed remote platform can be useful for pathology image analysis. The time consumption is depended mainly on the image size and speed of the internet connections. The presented implementation can be used for many types of analysis at different staining, tissue, morphometry approaches, etc. The significant problem is the implementation of the JSP page in the multithread form, that can be used parallelly by many users. The presented platform for image analysis in pathology can be especially useful for small laboratory without its own image analysis system. PMID:21489188

  1. Group Mirrors to Support Interaction Regulation in Collaborative Problem Solving

    ERIC Educational Resources Information Center

    Jermann, Patrick; Dillenbourg, Pierre

    2008-01-01

    Two experimental studies test the effect of group mirrors upon quantitative and qualitative aspects of participation in collaborative problem solving. Mirroring tools consist of a graphical representation of the group's actions which is dynamically updated and displayed to the collaborators. In addition, metacognitive tools display a standard for…

  2. Evidence-Based Concept Mapping for the Athletic Training Student

    ERIC Educational Resources Information Center

    Speicher, Timothy E.; Martin, Malissa; Zigmont, Jason

    2013-01-01

    Context: A concept map is a graphical and cognitive tool that enables learners to link together interrelated concepts using propositions or statements that answer a posed problem. As an assessment tool, concept mapping reveals a learner's research skill proficiency and cognitive processing. Background: The identification and organization of the…

  3. Python Spectral Analysis Tool (PySAT) for Preprocessing, Multivariate Analysis, and Machine Learning with Point Spectra

    NASA Astrophysics Data System (ADS)

    Anderson, R. B.; Finch, N.; Clegg, S.; Graff, T.; Morris, R. V.; Laura, J.

    2017-06-01

    We present a Python-based library and graphical interface for the analysis of point spectra. The tool is being developed with a focus on methods used for ChemCam data, but is flexible enough to handle spectra from other instruments.

  4. Infographics: An Innovative Tool to Capture Consumers' Attention

    ERIC Educational Resources Information Center

    Niebaum, Kelly; Cunningham-Sabo, Leslie; Carroll, Jan; Bellows, Laura

    2015-01-01

    Using infographics as educational tools has emerged as a strategy to reach consumers in today's information-saturated environment. Through the use of engaging and informative graphics, educators can deliver meaningful messages tailored to targeted audiences. Varying types of effectively designed infographics can be used to capture the attention of…

  5. Computerized power supply analysis: State equation generation and terminal models

    NASA Technical Reports Server (NTRS)

    Garrett, S. J.

    1978-01-01

    To aid engineers that design power supply systems two analysis tools that can be used with the state equation analysis package were developed. These tools include integration routines that start with the description of a power supply in state equation form and yield analytical results. The first tool uses a computer program that works with the SUPER SCEPTRE circuit analysis program and prints the state equation for an electrical network. The state equations developed automatically by the computer program are used to develop an algorithm for reducing the number of state variables required to describe an electrical network. In this way a second tool is obtained in which the order of the network is reduced and a simpler terminal model is obtained.

  6. Process and control systems for composites manufacturing

    NASA Technical Reports Server (NTRS)

    Tsiang, T. H.; Wanamaker, John L.

    1992-01-01

    A precise control of composite material processing would not only improve part quality, but it would also directly reduce the overall manufacturing cost. The development and incorporation of sensors will help to generate real-time information for material processing relationships and equipment characteristics. In the present work, the thermocouple, pressure transducer, and dielectrometer technologies were investigated. The monitoring sensors were integrated with the computerized control system in three non-autoclave fabrication techniques: hot-press, self contained tool (self heating and pressurizing), and pressure vessel). The sensors were implemented in the parts and tools.

  7. Evaluating geographic information systems technology

    USGS Publications Warehouse

    Guptill, Stephen C.

    1989-01-01

    Computerized geographic information systems (GISs) are emerging as the spatial data handling tools of choice for solving complex geographical problems. However, few guidelines exist for assisting potential users in identifying suitable hardware and software. A process to be followed in evaluating the merits of GIS technology is presented. Related standards and guidelines, software functions, hardware components, and benchmarking are discussed. By making users aware of all aspects of adopting GIS technology, they can decide if GIS is an appropriate tool for their application and, if so, which GIS should be used.

  8. Compact Graphical Representation of Phylogenetic Data and Metadata with GraPh1An

    DTIC Science & Technology

    2016-09-12

    pipelines . This allows for a higher degree of analysis reproducibility, but the software must correspondingly be available for local installation and callable...these operations are available in the GraPhlAn software repository). Reproducible integration with existing analysis tools and pipelines Graphical...from different analysis pipelines , generating the necessary input files for GraPhlAn. Export2graphlan directly supports MetaPhlAn2, LEfSe, and HUMAnN

  9. A Graphics Editor for Structured Analysis with a Data Dictionary.

    DTIC Science & Technology

    1987-12-01

    4-3 Human/Computer Interface Considerations 4-3 Screen Layout .... ............. 4-4 Menu System ..... .............. 4-6 Voice Feedback...central computer system . This project is a direct follow on to the 1986 thesis by James W. Urscheler. lie created an initial version of a tool (nicknamed...graphics information. Background r SADT. SADT is the name of SofTech’s methodology for doing requirement analysis and system design. It was first published

  10. The Complexity Analysis Tool

    DTIC Science & Technology

    1988-10-01

    overview of the complexity analysis tool ( CAT ), an automated tool which will analyze mission critical computer resources (MCCR) software. CAT is based...84 MAR UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE 19. ABSTRACT: (cont) CAT automates the metric for BASIC (HP-71), ATLAS (EQUATE), Ada (subset...UNIX 5.2). CAT analyzes source code and computes complexity on a module basis. CAT also generates graphic representations of the logic flow paths and

  11. Visuals, Path Control, and Knowledge Gain: Variables that Affect Students' Approval and Enjoyment of a Multimedia Text as a Learning Tool

    ERIC Educational Resources Information Center

    George-Palilonis, Jennifer; Filak, Vincent

    2010-01-01

    As graphically driven, animated, interactive applications offer educators new opportunities for shaping course content, new avenues for research arise as well. Along with these developments comes a need to study the effectiveness of the individual tools at our disposal as well as various methods for integrating those tools in a classroom setting.…

  12. Simulation environment and graphical visualization environment: a COPD use-case

    PubMed Central

    2014-01-01

    Background Today, many different tools are developed to execute and visualize physiological models that represent the human physiology. Most of these tools run models written in very specific programming languages which in turn simplify the communication among models. Nevertheless, not all of these tools are able to run models written in different programming languages. In addition, interoperability between such models remains an unresolved issue. Results In this paper we present a simulation environment that allows, first, the execution of models developed in different programming languages and second the communication of parameters to interconnect these models. This simulation environment, developed within the Synergy-COPD project, aims at helping and supporting bio-researchers and medical students understand the internal mechanisms of the human body through the use of physiological models. This tool is composed of a graphical visualization environment, which is a web interface through which the user can interact with the models, and a simulation workflow management system composed of a control module and a data warehouse manager. The control module monitors the correct functioning of the whole system. The data warehouse manager is responsible for managing the stored information and supporting its flow among the different modules. This simulation environment has been validated with the integration of three models: two deterministic, i.e. based on linear and differential equations, and one probabilistic, i.e., based on probability theory. These models have been selected based on the disease under study in this project, i.e., chronic obstructive pulmonary disease. Conclusion It has been proved that the simulation environment presented here allows the user to research and study the internal mechanisms of the human physiology by the use of models via a graphical visualization environment. A new tool for bio-researchers is ready for deployment in various use cases scenarios. PMID:25471327

  13. CAVER Analyst 1.0: graphic tool for interactive visualization and analysis of tunnels and channels in protein structures.

    PubMed

    Kozlikova, Barbora; Sebestova, Eva; Sustr, Vilem; Brezovsky, Jan; Strnad, Ondrej; Daniel, Lukas; Bednar, David; Pavelka, Antonin; Manak, Martin; Bezdeka, Martin; Benes, Petr; Kotry, Matus; Gora, Artur; Damborsky, Jiri; Sochor, Jiri

    2014-09-15

    The transport of ligands, ions or solvent molecules into proteins with buried binding sites or through the membrane is enabled by protein tunnels and channels. CAVER Analyst is a software tool for calculation, analysis and real-time visualization of access tunnels and channels in static and dynamic protein structures. It provides an intuitive graphic user interface for setting up the calculation and interactive exploration of identified tunnels/channels and their characteristics. CAVER Analyst is a multi-platform software written in JAVA. Binaries and documentation are freely available for non-commercial use at http://www.caver.cz. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  14. Prototype Packaged Databases and Software in Health

    PubMed Central

    Gardenier, Turkan K.

    1980-01-01

    This paper describes the recent demand for packaged databases and software for health applications in light of developments in mini-and micro-computer technology. Specific features for defining prospective user groups are discussed; criticisms generated for large-scale epidemiological data use as a means of replacing clinical trials and associated controls are posed to the reader. The available collaborative efforts for access and analysis of jointly structured health data are stressed, with recommendations for new analytical techniques specifically geared to monitoring data such as the CTSS (Cumulative Transitional State Score) generated for tacking ongoing patient status over time in clinical trials. Examples of graphic display are given from the Domestic Information Display System (DIDS) which is a collaborative multi-agency effort to computerize and make accessible user-specified U.S. and local maps relating to health, environment, socio-economic and energy data.

  15. Fiber Optic Communication System For Medical Images

    NASA Astrophysics Data System (ADS)

    Arenson, Ronald L.; Morton, Dan E.; London, Jack W.

    1982-01-01

    This paper discusses a fiber optic communication system linking ultrasound devices, Computerized tomography scanners, Nuclear Medicine computer system, and a digital fluoro-graphic system to a central radiology research computer. These centrally archived images are available for near instantaneous recall at various display consoles. When a suitable laser optical disk is available for mass storage, more extensive image archiving will be added to the network including digitized images of standard radiographs for comparison purposes and for remote display in such areas as the intensive care units, the operating room, and selected outpatient departments. This fiber optic system allows for a transfer of high resolution images in less than a second over distances exceeding 2,000 feet. The advantages of using fiber optic cables instead of typical parallel or serial communication techniques will be described. The switching methodology and communication protocols will also be discussed.

  16. Information Processing in Nursing Information Systems: An Evaluation Study from a Developing Country.

    PubMed

    Samadbeik, Mahnaz; Shahrokhi, Nafiseh; Saremian, Marzieh; Garavand, Ali; Birjandi, Mahdi

    2017-01-01

    In recent years, information technology has been introduced in the nursing departments of many hospitals to support their daily tasks. Nurses are the largest end user group in Hospital Information Systems (HISs). This study was designed to evaluate data processing in the Nursing Information Systems (NISs) utilized in many university hospitals in Iran. This was a cross-sectional study. The population comprised all nurse managers and NIS users of the five training hospitals in Khorramabad city ( N = 71). The nursing subset of HIS-Monitor questionnaire was used to collect the data. Data were analyzed by the descriptive-analytical method and the inductive content analysis. The results indicated that the nurses participating in the study did not take a desirable advantage of paper (2.02) and computerized (2.34) information processing tools to perform nursing tasks. Moreover, the less work experience nurses have, the further they utilize computer tools for processing patient discharge information. The "readability of patient information" and "repetitive and time-consuming documentation" were stated as the most important expectations and problems regarding the HIS by the participating nurses, respectively. The nurses participating in the present study used to utilize paper and computerized information processing tools together to perform nursing practices. Therefore, it is recommended that the nursing process redesign coincides with NIS implementation in the health care centers.

  17. Development of Response Surface Models for Rapid Analysis & Multidisciplinary Optimization of Launch Vehicle Design Concepts

    NASA Technical Reports Server (NTRS)

    Unal, Resit

    1999-01-01

    Multdisciplinary design optimization (MDO) is an important step in the design and evaluation of launch vehicles, since it has a significant impact on performance and lifecycle cost. The objective in MDO is to search the design space to determine the values of design parameters that optimize the performance characteristics subject to system constraints. Vehicle Analysis Branch (VAB) at NASA Langley Research Center has computerized analysis tools in many of the disciplines required for the design and analysis of launch vehicles. Vehicle performance characteristics can be determined by the use of these computerized analysis tools. The next step is to optimize the system performance characteristics subject to multidisciplinary constraints. However, most of the complex sizing and performance evaluation codes used for launch vehicle design are stand-alone tools, operated by disciplinary experts. They are, in general, difficult to integrate and use directly for MDO. An alternative has been to utilize response surface methodology (RSM) to obtain polynomial models that approximate the functional relationships between performance characteristics and design variables. These approximation models, called response surface models, are then used to integrate the disciplines using mathematical programming methods for efficient system level design analysis, MDO and fast sensitivity simulations. A second-order response surface model of the form given has been commonly used in RSM since in many cases it can provide an adequate approximation especially if the region of interest is sufficiently limited.

  18. Clinical map document based on XML (cMDX): document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens.

    PubMed

    Eminaga, Okyaz; Hinkelammert, Reemt; Semjonow, Axel; Neumann, Joerg; Abbas, Mahmoud; Koepke, Thomas; Bettendorf, Olaf; Eltze, Elke; Dugas, Martin

    2010-11-15

    The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa). The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension) with the textual data (e.g. histological patterns). The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25). 54% of PCa showed a multifocal growth pattern. cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis.

  19. Clinical map document based on XML (cMDX): document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens

    PubMed Central

    2010-01-01

    Background The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa). The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. Methods The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension) with the textual data (e.g. histological patterns). The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. Results The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25). 54% of PCa showed a multifocal growth pattern. Conclusions cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis. PMID:21078179

  20. An Embedded Rule-Based Diagnostic Expert System in Ada

    NASA Technical Reports Server (NTRS)

    Jones, Robert E.; Liberman, Eugene M.

    1992-01-01

    Ada is becoming an increasingly popular programming language for large Government-funded software projects. Ada with it portability, transportability, and maintainability lends itself well to today's complex programming environment. In addition, expert systems have also assumed a growing role in providing human-like reasoning capability expertise for computer systems. The integration is discussed of expert system technology with Ada programming language, especially a rule-based expert system using an ART-Ada (Automated Reasoning Tool for Ada) system shell. NASA Lewis was chosen as a beta test site for ART-Ada. The test was conducted by implementing the existing Autonomous Power EXpert System (APEX), a Lisp-based power expert system, in ART-Ada. Three components, the rule-based expert systems, a graphics user interface, and communications software make up SMART-Ada (Systems fault Management with ART-Ada). The rules were written in the ART-Ada development environment and converted to Ada source code. The graphics interface was developed with the Transportable Application Environment (TAE) Plus, which generates Ada source code to control graphics images. SMART-Ada communicates with a remote host to obtain either simulated or real data. The Ada source code generated with ART-Ada, TAE Plus, and communications code was incorporated into an Ada expert system that reads the data from a power distribution test bed, applies the rule to determine a fault, if one exists, and graphically displays it on the screen. The main objective, to conduct a beta test on the ART-Ada rule-based expert system shell, was achieved. The system is operational. New Ada tools will assist in future successful projects. ART-Ada is one such tool and is a viable alternative to the straight Ada code when an application requires a rule-based or knowledge-based approach.

  1. A study of computer graphics technology in application of communication resource management

    NASA Astrophysics Data System (ADS)

    Li, Jing; Zhou, Liang; Yang, Fei

    2017-08-01

    With the development of computer technology, computer graphics technology has been widely used. Especially, the success of object-oriented technology and multimedia technology promotes the development of graphics technology in the computer software system. Therefore, the computer graphics theory and application technology have become an important topic in the field of computer, while the computer graphics technology becomes more and more extensive in various fields of application. In recent years, with the development of social economy, especially the rapid development of information technology, the traditional way of communication resource management cannot effectively meet the needs of resource management. In this case, the current communication resource management is still using the original management tools and management methods, resource management equipment management and maintenance, which brought a lot of problems. It is very difficult for non-professionals to understand the equipment and the situation in communication resource management. Resource utilization is relatively low, and managers cannot quickly and accurately understand the resource conditions. Aimed at the above problems, this paper proposes to introduce computer graphics technology into the communication resource management. The introduction of computer graphics not only makes communication resource management more vivid, but also reduces the cost of resource management and improves work efficiency.

  2. Computerized pharmaceutical intervention to reduce reconciliation errors at hospital discharge in Spain: an interrupted time-series study.

    PubMed

    García-Molina Sáez, C; Urbieta Sanz, E; Madrigal de Torres, M; Vicente Vera, T; Pérez Cárceles, M D

    2016-04-01

    It is well known that medication reconciliation at discharge is a key strategy to ensure proper drug prescription and the effectiveness and safety of any treatment. Different types of interventions to reduce reconciliation errors at discharge have been tested, many of which are based on the use of electronic tools as they are useful to optimize the medication reconciliation process. However, not all countries are progressing at the same speed in this task and not all tools are equally effective. So it is important to collate updated country-specific data in order to identify possible strategies for improvement in each particular region. Our aim therefore was to analyse the effectiveness of a computerized pharmaceutical intervention to reduce reconciliation errors at discharge in Spain. A quasi-experimental interrupted time-series study was carried out in the cardio-pneumology unit of a general hospital from February to April 2013. The study consisted of three phases: pre-intervention, intervention and post-intervention, each involving 23 days of observations. At the intervention period, a pharmacist was included in the medical team and entered the patient's pre-admission medication in a computerized tool integrated into the electronic clinical history of the patient. The effectiveness was evaluated by the differences between the mean percentages of reconciliation errors in each period using a Mann-Whitney U test accompanied by Bonferroni correction, eliminating autocorrelation of the data by first using an ARIMA analysis. In addition, the types of error identified and their potential seriousness were analysed. A total of 321 patients (119, 105 and 97 in each phase, respectively) were included in the study. For the 3966 medicaments recorded, 1087 reconciliation errors were identified in 77·9% of the patients. The mean percentage of reconciliation errors per patient in the first period of the study was 42·18%, falling to 19·82% during the intervention period (P = 0·000). When the intervention was withdrawn, the mean percentage of reconciliation errors increased again to 27·72% (P = 0·008). The difference between the percentages of pre- and post-intervention periods was statistically significant (P = 0·000). Most reconciliation errors were due to omission (46·7%) or incomplete prescription (43·8%), and 35·3% of which could have caused harm to the patient. A computerized pharmaceutical intervention is shown to reduce reconciliation errors in the context of a high incidence of such errors. © 2016 John Wiley & Sons Ltd.

  3. Automation in the graphic arts

    NASA Astrophysics Data System (ADS)

    Truszkowski, Walt

    1995-04-01

    The CHIMES (Computer-Human Interaction Models) tool was designed to help solve a simply-stated but important problem, i.e., the problem of generating a user interface to a system that complies with established human factors standards and guidelines. Though designed for use in a fairly restricted user domain, i.e., spacecraft mission operations, the CHIMES system is essentially domain independent and applicable wherever graphical user interfaces of displays are to be encountered. The CHIMES philosophy and operating strategy are quite simple. Instead of requiring a human designer to actively maintain in his or her head the now encyclopedic knowledge that human factors and user interface specialists have evolved, CHIMES incorporates this information in its knowledge bases. When directed to evaluated a design, CHIMES determines and accesses the appropriate knowledge, performs an evaluation of the design against that information, determines whether the design is compliant with the selected guidelines and suggests corrective actions if deviations from guidelines are discovered. This paper will provide an overview of the capabilities of the current CHIMES tool and discuss the potential integration of CHIMES-like technology in automated graphic arts systems.

  4. The use of interactive computer vision and robot hand controllers for enhancing manufacturing safety

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Jacobus, Charles J.; Peurach, Thomas M.; Mitchell, Brian T.

    1994-01-01

    Current available robotic systems provide limited support for CAD-based model-driven visualization, sensing algorithm development and integration, and automated graphical planning systems. This paper describes ongoing work which provides the functionality necessary to apply advanced robotics to automated manufacturing and assembly operations. An interface has been built which incorporates 6-DOF tactile manipulation, displays for three dimensional graphical models, and automated tracking functions which depend on automated machine vision. A set of tools for single and multiple focal plane sensor image processing and understanding has been demonstrated which utilizes object recognition models. The resulting tool will enable sensing and planning from computationally simple graphical objects. A synergistic interplay between human and operator vision is created from programmable feedback received from the controller. This approach can be used as the basis for implementing enhanced safety in automated robotics manufacturing, assembly, repair and inspection tasks in both ground and space applications. Thus, an interactive capability has been developed to match the modeled environment to the real task environment for safe and predictable task execution.

  5. The use of interactive computer vision and robot hand controllers for enhancing manufacturing safety

    NASA Astrophysics Data System (ADS)

    Marzwell, Neville I.; Jacobus, Charles J.; Peurach, Thomas M.; Mitchell, Brian T.

    1994-02-01

    Current available robotic systems provide limited support for CAD-based model-driven visualization, sensing algorithm development and integration, and automated graphical planning systems. This paper describes ongoing work which provides the functionality necessary to apply advanced robotics to automated manufacturing and assembly operations. An interface has been built which incorporates 6-DOF tactile manipulation, displays for three dimensional graphical models, and automated tracking functions which depend on automated machine vision. A set of tools for single and multiple focal plane sensor image processing and understanding has been demonstrated which utilizes object recognition models. The resulting tool will enable sensing and planning from computationally simple graphical objects. A synergistic interplay between human and operator vision is created from programmable feedback received from the controller. This approach can be used as the basis for implementing enhanced safety in automated robotics manufacturing, assembly, repair and inspection tasks in both ground and space applications. Thus, an interactive capability has been developed to match the modeled environment to the real task environment for safe and predictable task execution.

  6. AWE: Aviation Weather Data Visualization Environment

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly; Lodha, Suresh K.

    2000-01-01

    The two official sources for aviation weather reports both provide weather information to a pilot in a textual format. A number of systems have recently become available to help pilots with the visualization task by providing much of the data graphically. However, two types of aviation weather data are still not being presented graphically. These are airport-specific current weather reports (known as meteorological observations, or METARs) and forecast weather reports (known as terminal area forecasts, or TAFs). Our system, Aviation Weather Environment (AWE), presents intuitive graphical displays for both METARs and TAFs, as well as winds aloft forecasts. We start with a computer-generated textual aviation weather briefing. We map this briefing onto a cartographic grid specific to the pilot's area of interest. The pilot is able to obtain aviation-specific weather for the entire area or for his specific route. The route, altitude, true airspeed, and proposed departure time can each be modified in AWE. Integral visual display of these three elements of weather reports makes AWE a useful planning tool, as well as a weather briefing tool.

  7. Army-NASA aircrew/aircraft integration program (A3I) software detailed design document, phase 3

    NASA Technical Reports Server (NTRS)

    Banda, Carolyn; Chiu, Alex; Helms, Gretchen; Hsieh, Tehming; Lui, Andrew; Murray, Jerry; Shankar, Renuka

    1990-01-01

    The capabilities and design approach of the MIDAS (Man-machine Integration Design and Analysis System) computer-aided engineering (CAE) workstation under development by the Army-NASA Aircrew/Aircraft Integration Program is detailed. This workstation uses graphic, symbolic, and numeric prototyping tools and human performance models as part of an integrated design/analysis environment for crewstation human engineering. Developed incrementally, the requirements and design for Phase 3 (Dec. 1987 to Jun. 1989) are described. Software tools/models developed or significantly modified during this phase included: an interactive 3-D graphic cockpit design editor; multiple-perspective graphic views to observe simulation scenarios; symbolic methods to model the mission decomposition, equipment functions, pilot tasking and loading, as well as control the simulation; a 3-D dynamic anthropometric model; an intermachine communications package; and a training assessment component. These components were successfully used during Phase 3 to demonstrate the complex interactions and human engineering findings involved with a proposed cockpit communications design change in a simulated AH-64A Apache helicopter/mission that maps to empirical data from a similar study and AH-1 Cobra flight test.

  8. Automated Computerized Analysis of Speechin Psychiatric Disorders

    PubMed Central

    Cohen, Alex S.; Elvevåg, Brita

    2014-01-01

    Purpose of Review Disturbances in communication are a hallmark of severe mental illnesses. Recent technological advances have paved the way for objectifying communication using automated computerized linguistic and acoustic analysis. We review recent studies applying various computer-based assessments to the natural language produced by adult patients with severe mental illness. Recent Findings Automated computerized methods afford tools with which it is possible to objectively evaluate patients in a reliable, valid and efficient manner that complements human ratings. Crucially, these measures correlate with important clinical measures. The clinical relevance of these novel metrics has been demonstrated by showing their relationship to functional outcome measures, their in vivo link to classic ‘language’ regions in the brain, and, in the case of linguistic analysis, their relationship to candidate genes for severe mental illness. Summary Computer based assessments of natural language afford a framework with which to measure communication disturbances in adults with SMI. Emerging evidence suggests that they can be reliable and valid, and overcome many practical limitations of more traditional assessment methods. The advancement of these technologies offers unprecedented potential for measuring and understanding some of the most crippling symptoms of some of the most debilitating illnesses known to humankind. PMID:24613984

  9. Virtual reality simulation: using three-dimensional technology to teach nursing students.

    PubMed

    Jenson, Carole E; Forsyth, Diane McNally

    2012-06-01

    The use of computerized technology is rapidly growing in the classroom and in healthcare. An emerging computer technology strategy for nursing education is the use of virtual reality simulation. This computer-based three-dimensional educational tool simulates real-life patient experiences in a risk-free environment, allows for repeated practice sessions, requires clinical decision making, exposes students to diverse patient conditions, provides immediate feedback, and is portable. The purpose of this article was to review the importance of virtual reality simulation as a computerized teaching strategy. In addition, a project to explore readiness of nursing faculty at one major Midwestern university for the use of virtual reality simulation as a computerized teaching strategy is described where faculty thought virtual reality simulation would increase students' knowledge of an intravenous line insertion procedure. Faculty who practiced intravenous catheter insertion via virtual reality simulation expressed a wide range of learning experiences from using virtual reality simulation that is congruent with the literature regarding the barriers to student learning. Innovative teaching strategies, such as virtual reality simulation, address barriers of increasing patient acuity, high student-to-faculty ratio, patient safety concerns from faculty, and student anxiety and can offer rapid feedback to students.

  10. A survey of tools for the analysis of quantitative PCR (qPCR) data.

    PubMed

    Pabinger, Stephan; Rödiger, Stefan; Kriegner, Albert; Vierlinger, Klemens; Weinhäusel, Andreas

    2014-09-01

    Real-time quantitative polymerase-chain-reaction (qPCR) is a standard technique in most laboratories used for various applications in basic research. Analysis of qPCR data is a crucial part of the entire experiment, which has led to the development of a plethora of methods. The released tools either cover specific parts of the workflow or provide complete analysis solutions. Here, we surveyed 27 open-access software packages and tools for the analysis of qPCR data. The survey includes 8 Microsoft Windows, 5 web-based, 9 R-based and 5 tools from other platforms. Reviewed packages and tools support the analysis of different qPCR applications, such as RNA quantification, DNA methylation, genotyping, identification of copy number variations, and digital PCR. We report an overview of the functionality, features and specific requirements of the individual software tools, such as data exchange formats, availability of a graphical user interface, included procedures for graphical data presentation, and offered statistical methods. In addition, we provide an overview about quantification strategies, and report various applications of qPCR. Our comprehensive survey showed that most tools use their own file format and only a fraction of the currently existing tools support the standardized data exchange format RDML. To allow a more streamlined and comparable analysis of qPCR data, more vendors and tools need to adapt the standardized format to encourage the exchange of data between instrument software, analysis tools, and researchers.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wooten, Hasani Omar; Aslam, Tariq Dennis; Whitley, Von Howard

    A graphical user interface (GUI) tool has been developed that facilitates the visualization and analysis of the Chapman-Jouguet state for high explosives gaseous products using the Jones- Wilkins-Lee equation of state.

  12. The effects of 3D interactive animated graphics on student learning and attitudes in computer-based instruction

    NASA Astrophysics Data System (ADS)

    Moon, Hye Sun

    Visuals are most extensively used as instructional tools in education to present spatially-based information. Recent computer technology allows the generation of 3D animated visuals to extend the presentation in computer-based instruction. Animated visuals in 3D representation not only possess motivational value that promotes positive attitudes toward instruction but also facilitate learning when the subject matter requires dynamic motion and 3D visual cue. In this study, three questions are explored: (1) how 3D graphics affects student learning and attitude, in comparison with 2D graphics; (2) how animated graphics affects student learning and attitude, in comparison with static graphics; and (3) whether the use of 3D graphics, when they are supported by interactive animation, is the most effective visual cues to improve learning and to develop positive attitudes. A total of 145 eighth-grade students participated in a 2 x 2 factorial design study. The subjects were randomly assigned to one of four computer-based instructions: 2D static; 2D animated; 3D static; and 3D animated. The results indicated that: (1) Students in the 3D graphic condition exhibited more positive attitudes toward instruction than those in the 2D graphic condition. No group differences were found between the posttest score of 3D graphic condition and that of 2D graphic condition. However, students in the 3D graphic condition took less time for information retrieval on posttest than those in the 2D graphic condition. (2) Students in the animated graphic condition exhibited slightly more positive attitudes toward instruction than those in the static graphic condition. No group differences were found between the posttest score of animated graphic condition and that of static graphic condition. However, students in the animated graphic condition took less time for information retrieval on posttest than those in the static graphic condition. (3) Students in the 3D animated graphic condition exhibited more positive attitudes toward instruction than those in other treatment conditions (2D static, 2D animated, and 3D static conditions). No group differences were found in the posttest scores among four treatment conditions. However, students in the 3D animated condition took less time for information retrieval on posttest than those in other treatment conditions.

  13. Graphics Flutter Analysis Methods, an interactive computing system at Lockheed-California Company

    NASA Technical Reports Server (NTRS)

    Radovcich, N. A.

    1975-01-01

    An interactive computer graphics system, Graphics Flutter Analysis Methods (GFAM), was developed to complement FAMAS, a matrix-oriented batch computing system, and other computer programs in performing complex numerical calculations using a fully integrated data management system. GFAM has many of the matrix operation capabilities found in FAMAS, but on a smaller scale, and is utilized when the analysis requires a high degree of interaction between the engineer and computer, and schedule constraints exclude the use of batch entry programs. Applications of GFAM to a variety of preliminary design, development design, and project modification programs suggest that interactive flutter analysis using matrix representations is a feasible and cost effective computing tool.

  14. Advanced mathematical on-line analysis in nuclear experiments. Usage of parallel computing CUDA routines in standard root analysis

    NASA Astrophysics Data System (ADS)

    Grzeszczuk, A.; Kowalski, S.

    2015-04-01

    Compute Unified Device Architecture (CUDA) is a parallel computing platform developed by Nvidia for increase speed of graphics by usage of parallel mode for processes calculation. The success of this solution has opened technology General-Purpose Graphic Processor Units (GPGPUs) for applications not coupled with graphics. The GPGPUs system can be applying as effective tool for reducing huge number of data for pulse shape analysis measures, by on-line recalculation or by very quick system of compression. The simplified structure of CUDA system and model of programming based on example Nvidia GForce GTX580 card are presented by our poster contribution in stand-alone version and as ROOT application.

  15. VAGUE: a graphical user interface for the Velvet assembler.

    PubMed

    Powell, David R; Seemann, Torsten

    2013-01-15

    Velvet is a popular open-source de novo genome assembly software tool, which is run from the Unix command line. Most of the problems experienced by new users of Velvet revolve around constructing syntactically and semantically correct command lines, getting input files into acceptable formats and assessing the output. Here, we present Velvet Assembler Graphical User Environment (VAGUE), a multi-platform graphical front-end for Velvet. VAGUE aims to make sequence assembly accessible to a wider audience and to facilitate better usage amongst existing users of Velvet. VAGUE is implemented in JRuby and targets the Java Virtual Machine. It is available under an open-source GPLv2 licence from http://www.vicbioinformatics.com/. torsten.seemann@monash.edu.

  16. Evaluation of Internet-Based Clinical Decision Support Systems

    PubMed Central

    Thomas, Karl W; Dayton, Charles S

    1999-01-01

    Background Scientifically based clinical guidelines have become increasingly used to educate physicians and improve quality of care. While individual guidelines are potentially useful, repeated studies have shown that guidelines are ineffective in changing physician behavior. The Internet has evolved as a potentially useful tool for guideline education, dissemination, and implementation because of its open standards and its ability to provide concise, relevant clinical information at the location and time of need. Objective Our objective was to develop and test decision support systems (DSS) based on clinical guidelines which could be delivered over the Internet for two disease models: asthma and tuberculosis (TB) preventive therapy. Methods Using open standards of HTML and CGI, we developed an acute asthma severity assessment DSS and a preventative tuberculosis treatment DSS based on content from national guidelines that are recognized as standards of care. Both DSS's are published on the Internet and operate through a decision algorithm developed from the parent guidelines with clinical information provided by the user at the point of clinical care. We tested the effectiveness of each DSS in influencing physician decisions using clinical scenario testing. Results We first validated the asthma algorithm by comparing asthma experts' decisions with the decisions reached by nonpulmonary nurses using the computerized DSS. Using the DSS, nurses scored the same as experts (89% vs. 88%; p = NS). Using the same scenario test instrument, we next compared internal medicine residents using the DSS with residents using a printed version of the National Asthma Education Program-2 guidelines. Residents using the computerized DSS scored significantly better than residents using the paper-based guidelines (92% vs. 84%; p <0.002). We similarly compared residents using the computerized TB DSS to residents using a printed reference card; the residents using the computerized DSS scored significantly better (95.8% vs. 56.6% correct; p<0.001). Conclusions Previous work has shown that guidelines disseminated through traditional educational interventions have minimal impact on physician behavior. Although computerized DSS have been effective in altering physician behavior, many of these systems are not widely available. We have developed two clinical DSS's based on national guidelines and published them on the Internet. Both systems improved physician compliance with national guidelines when tested in clinical scenarios. By providing information that is coupled to relevant activity, we expect that these widely available DSS's will serve as effective educational tools to positively impact physician behavior. PMID:11720915

  17. D-WISE: Diabetes Web-Centric Information and Support Environment: conceptual specification and proposed evaluation.

    PubMed

    Abidi, Samina; Vallis, Michael; Raza Abidi, Syed Sibte; Piccinini-Vallis, Helena; Imran, Syed Ali

    2014-06-01

    To develop and evaluate Diabetes Web-Centric Information and Support Environment (D-WISE) that offers 1) a computerized decision-support system to assist physicians to A) use the Canadian Diabetes Association clinical practice guidelines (CDA CPGs) to recommend evidence-informed interventions; B) offer a computerized readiness assessment strategy to help physicians administer behaviour-change strategies to help patients adhere to disease self-management programs; and 2) a patient-specific diabetes self-management application, accessible through smart mobile devices, that offers behaviour-change interventions to engage patients in self-management. The above-mentioned objectives were pursued through a knowledge management approach that involved 1) Translation of paper-based CDA CPGs and behaviour-change models as computerized decision-support tools that will assist physicians to offer evidence-informed and personalized diabetes management and behaviour-change strategies; 2) Engagement of patients in their diabetes care by generating a diabetes self-management program that takes into account their preferences, challenges and needs; 3) Empowering patients to self-manage their condition by providing them with personalized educational and motivational messages through a mobile self-management application. The theoretical foundation of our research is grounded in behaviour-change models and healthcare knowledge management. We used 1) knowledge modelling to computerize the paper-based CDA CPGs and behaviour-change models, in particular, the behaviour-change strategy elements of A) readiness-to-change assessments; B) motivation-enhancement interventions categorized along the lines of patients' being ready, ambivalent or not ready; and C) self-efficacy enhancement. The CDA CPGs and the behaviour-change models are modelled and computerized in terms of A) a diabetes management ontology that serves as the knowledge resource for all the services offered by D-WISE; B) decision support services that use logic-based reasoning algorithms to utilize the knowledge encoded within the diabetes management ontology to assist physicians by recommending patient-specific diabetes-management interventions and behaviour-change strategies; C) a mobile diabetes self-management application to engage and educate diabetes patients to self-manage their condition in a home-based setting while working in concert with their family physicians. We have been successful in creating and conducting a usability assessment of the physician decision support tool. These results will be published once the patient self- management application has been evaluated. D-WISE will be evaluated through pilot studies measuring 1) the usability of the e-Health interventions; and 2) the impact of the interventions on patients' behaviour changes and diabetes control. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  18. ESDAPT - APT PROGRAMMING EDITOR AND INTERPRETER

    NASA Technical Reports Server (NTRS)

    Premack, T.

    1994-01-01

    ESDAPT is a graphical programming environment for developing APT (Automatically Programmed Tool) programs for controlling numerically controlled machine tools. ESDAPT has a graphical user interface that provides the user with an APT syntax sensitive text editor and windows for displaying geometry and tool paths. APT geometry statement can also be created using menus and screen picks. ESDAPT interprets APT geometry statements and displays the results in its view windows. Tool paths are generated by batching the APT source to an APT processor (COSMIC P-APT recommended). The tool paths are then displayed in the view windows. Hardcopy output of the view windows is in color PostScript format. ESDAPT is written in C-language, yacc, lex, and XView for use on Sun4 series computers running SunOS. ESDAPT requires 4Mb of disk space, 7Mb of RAM, and MIT's X Window System, Version 11 Release 4, or OpenWindows version 3 for execution. Program documentation in PostScript format and an executable for OpenWindows version 3 are provided on the distribution media. The standard distribution medium for ESDAPT is a .25 inch streaming magnetic tape cartridge (Sun QIC-24) in UNIX tar format. This program was developed in 1992.

  19. Semi-automatic image personalization tool for variable text insertion and replacement

    NASA Astrophysics Data System (ADS)

    Ding, Hengzhou; Bala, Raja; Fan, Zhigang; Eschbach, Reiner; Bouman, Charles A.; Allebach, Jan P.

    2010-02-01

    Image personalization is a widely used technique in personalized marketing,1 in which a vendor attempts to promote new products or retain customers by sending marketing collateral that is tailored to the customers' demographics, needs, and interests. With current solutions of which we are aware such as XMPie,2 DirectSmile,3 and AlphaPicture,4 in order to produce this tailored marketing collateral, image templates need to be created manually by graphic designers, involving complex grid manipulation and detailed geometric adjustments. As a matter of fact, the image template design is highly manual, skill-demanding and costly, and essentially the bottleneck for image personalization. We present a semi-automatic image personalization tool for designing image templates. Two scenarios are considered: text insertion and text replacement, with the text replacement option not offered in current solutions. The graphical user interface (GUI) of the tool is described in detail. Unlike current solutions, the tool renders the text in 3-D, which allows easy adjustment of the text. In particular, the tool has been implemented in Java, which introduces flexible deployment and eliminates the need for any special software or know-how on the part of the end user.

  20. PipeCraft: Flexible open-source toolkit for bioinformatics analysis of custom high-throughput amplicon sequencing data.

    PubMed

    Anslan, Sten; Bahram, Mohammad; Hiiesalu, Indrek; Tedersoo, Leho

    2017-11-01

    High-throughput sequencing methods have become a routine analysis tool in environmental sciences as well as in public and private sector. These methods provide vast amount of data, which need to be analysed in several steps. Although the bioinformatics may be applied using several public tools, many analytical pipelines allow too few options for the optimal analysis for more complicated or customized designs. Here, we introduce PipeCraft, a flexible and handy bioinformatics pipeline with a user-friendly graphical interface that links several public tools for analysing amplicon sequencing data. Users are able to customize the pipeline by selecting the most suitable tools and options to process raw sequences from Illumina, Pacific Biosciences, Ion Torrent and Roche 454 sequencing platforms. We described the design and options of PipeCraft and evaluated its performance by analysing the data sets from three different sequencing platforms. We demonstrated that PipeCraft is able to process large data sets within 24 hr. The graphical user interface and the automated links between various bioinformatics tools enable easy customization of the workflow. All analytical steps and options are recorded in log files and are easily traceable. © 2017 John Wiley & Sons Ltd.

Top