Sample records for computerized test battery

  1. Performances on the CogState and Standard Neuropsychological Batteries Among HIV Patients Without Dementia

    PubMed Central

    Overton, Edgar Turner; Kauwe, John S.K.; Paul, Rob; Tashima, Karen; Tate, David F.; Patel, Pragna; Carpenter, Chuck; Patty, David; Brooks, John T.; Clifford, David B

    2013-01-01

    HIV-associated neurocognitive disorders (HAND) remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (p<0.01). These data confirm previous correlation data with the computerized battery, yet illustrate remaining challenges for neurocognitive screening. PMID:21877204

  2. Performances on the CogState and standard neuropsychological batteries among HIV patients without dementia.

    PubMed

    Overton, Edgar Turner; Kauwe, John S K; Paul, Robert; Tashima, Karen; Tate, David F; Patel, Pragna; Carpenter, Charles C J; Patty, David; Brooks, John T; Clifford, David B

    2011-11-01

    HIV-associated neurocognitive disorders remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (P < 0.01). These data confirm previous correlation data with the computerized battery. Using the five significant parameters from the regression model in a Receiver Operating Characteristic curve, 90% of persons were accurately classified as being cognitively impaired or not. The test battery requires additional evaluation, specifically for identifying persons with mild impairment, a state upon which interventions may be effective.

  3. Evaluation Plan for the Computerized Adaptive Vocational Aptitude Battery.

    ERIC Educational Resources Information Center

    Green, Bert F.; And Others

    The United States Armed Services are planning to introduce computerized adaptive testing (CAT) into the Armed Services Vocational Aptitude Battery (ASVAB), which is a major part of the present personnel assessment procedures. Adaptive testing will improve efficiency greatly by assessing each candidate's answers as the test progresses and posing…

  4. Documentation of validity for the AT-SAT computerized test battery. Volume 2

    DOT National Transportation Integrated Search

    2001-03-01

    This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...

  5. Documentation of validity for the AT-SAT computerized test battery. Volume 1

    DOT National Transportation Integrated Search

    2001-03-01

    This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...

  6. Implementation of the Computerized Adaptive Version of the Armed Services Vocational Aptitude Battery.

    ERIC Educational Resources Information Center

    Curran, Linda T.; Jordan, Linda A.

    In the summer of 1996, the U.S. Armed Services will implement the computerized adaptive testing version of the Armed Services Vocational Aptitude Battery (CAT-ASVAB). When conversion is completed at the 65 targeted military entrance processing stations, about half the applicants will take this test version. This paper describes the efforts that…

  7. Equivalent-Groups versus Single-Group Equating Designs for the Accelerated CAT-ASVAB (Computerized Adaptive Test-Armed Services Vocational Aptitude Battery) Project.

    DTIC Science & Technology

    1987-01-01

    DESIGNS FOR THE ACCELERATED CAT -ASVAB * PROJECT Peter H. Stoloff DTIC’- , " SELECTE -NOV 2 3 987 A Division of Hudson Institute CENTER FOR NAVAL ANALYSES...65153M C0031 SI TITLE (Include Security Classification) Equivalent-Groups Versus Single-Group Equating Designs For The Accelerated CAT -ASVAB Project...GROUP ACAP (Accelerated CAT -ASVAB Program), Aptitude tests, ASVAB (Armed 05 10 Services Vocational Aptitude Battery), CAT (Computerized Adaptive Test

  8. Computerized Adaptive Testing: From Inquiry to Operation [Book Review].

    ERIC Educational Resources Information Center

    Gierl, Mark J.

    1998-01-01

    This book documents the research, development, and implementation efforts that allowed the U.S. Department of Defense to initiate the Computerized Adaptive Testing Armed Services Vocational Aptitude Battery Program for enlistment testing. Traces the history of this program over 30 years. (SLD)

  9. Further Evidence for a Multifaceted Model of Mental Speed: Factor Structure and Validity of Computerized Measures

    ERIC Educational Resources Information Center

    Danthiir, Vanessa; Wilhelm, Oliver; Roberts, Richard D.

    2012-01-01

    The purpose of this study was to replicate the structure of mental speed and relations evidenced with fluid intelligence (Gf) found in a number of recent studies. Specifically, a battery of computerized tasks examined whether results with paper-and-pencil assessments held across different test media. Participants (N = 186) completed the battery,…

  10. The Computerized Adaptive Testing System Development Project.

    ERIC Educational Resources Information Center

    McBride, James R.; Sympson, J. B.

    The Computerized Adaptive Testing (CAT) project is a joint Armed Services coordinated effort to develop and evaluate a system for automated, adaptive administration of the Armed Services Vocational Aptitude Battery (ASVAB). The CAT is a system for administering personnel tests that differs from conventional test administration in two major…

  11. Some performance effects of age and low blood alcohol levels on a computerized neuropsychological test.

    DOT National Transportation Integrated Search

    1995-02-01

    COGSCREEN is a computerized test battery developed for the Federal Aviation Administration as an airman neuropsychological screening instrument for cognitive functioning. This study explored a multifaceted application of the sensitivity of the batter...

  12. Reliability and validity of the Arabic version of the computerized Battery for Neuropsychological Evaluation of Children (BENCI).

    PubMed

    Fasfous, Ahmed F; Peralta-Ramirez, Maria Isabel; Pérez-Marfil, María Nieves; Cruz-Quintana, Francisco; Catena-Martinez, Andrés; Pérez-García, Miguel

    2015-01-01

    Batería de Evaluación Neuropsicológica Infantil (BENCI) is a computerized battery for the neuropsychological evaluation of children. This battery has been used in different studies to evaluate neuropsychological functions and neurodevelopment in children. The objective of this study is to test the validity and reliability of the first Arabic version of the BENCI on an Arabic population where neuropsychological tests are very scarce. We administrate the BENCI to 198 school-age children (98 boys and 100 girls) from Morocco. To examine the test retest reliability of the BENCI battery, we administered the battery 2 times to 43 children (23 boys and 20 girls) with 15 days in between the pre- and posttest. The results revealed good validity and reliability of the battery in Arabic children. Also, the BENCI battery has demonstrated the capacity to differentiate between children by their age group. This battery can be of great use to both the research and clinical areas of Arabic countries and/or in assistance to Arabic immigrants that live outside of their native country.

  13. Computerized cognitive testing in patients with type I Gaucher disease: effects of enzyme replacement and substrate reduction.

    PubMed

    Elstein, Deborah; Guedalia, Judith; Doniger, Glen M; Simon, Ely S; Antebi, Vered; Arnon, Yael; Zimran, Ari

    2005-02-01

    Because of concern for drug-induced cognitive dysfunction during clinical trials using substrate reduction therapy (miglustat) in type 1 Gaucher disease and because it has been suggested that some patients with type 1 Gaucher disease may develop neurocognitive impairment as part of the natural history, two different batteries of neuropsychological tests were devised to examine these issues. Using these tests, cognitive function was assessed in patients treated with miglustat, in patients receiving enzyme replacement (standard care for symptomatic patients), and in untreated (milder) patients. For this study, 55/60 patients exposed to miglustat in Israel participated in psychologist-administered testing; 36/55 participated in computerized testing. Of these, 31 enzyme-treated patients and 22 untreated patients participated in the psychologist-administered testing, and 15 enzyme-treated patients and 18 untreated patients participated in computerized testing. The psychologist-administered battery consisted of 18 standard neuropsychological subtests specific to executive and visuospatial functioning. The computerized battery (Mindstreams, NeuroTrax Corp., New York, NY) consisted of 10 subtests tapping multiple cognitive domains. Between-group analyses for each modality compared cognitive performance. In the psychologist-administered testing, patients exposed to miglustat performed significantly less well than the other groups in 5/18 subtests. On the computerized tests, all patients performed comparably to normal controls. Scores in patients exposed to miglustat were higher than in untreated patients, particularly in visuospatial function, whereas enzyme-treated patients performed less well. However, with the exception of visuospatial function, these results were not statistically significant. It is unclear why different testing methods yielded discordant results. Any dysfunction suggested by the current study is apparently subtle and of doubtful clinical relevance given that cognitive status did not interfere with patients' daily intellectual function. The computerized battery has methodological advantages (e.g., language options, objectivity, brevity, and ease of use) that make it well-suited for longitudinal studies, for long-term surveillance of substrate reduction therapy as well as for comparisons with other lysosomal storage disorders and other chronic diseases. These preliminary findings should allay fears of cognitive dysfunction due to short-term miglustat therapy.

  14. Microcomputer Network for Computerized Adaptive Testing (CAT). [Final Report, FY81-83].

    ERIC Educational Resources Information Center

    Quan, Baldwin; And Others

    Computerized adaptive testing (CAT) offers the opportunity to replace paper-and-pencil aptitude tests such as the Armed Services Vocational Aptitude Battery with shorter, more accurate, and more secure computer-administered tests. Its potential advantages need to be verified by experimental administration of automated tests to military recruit…

  15. Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.

    PubMed

    Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe

    2008-01-01

    The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.

  16. Comparison of blast-exposed OEF/OIF veterans with and without a history of TBI symptoms on a brief computerized neuropsychological battery.

    PubMed

    Kalkstein, Solomon; Scott, J Cobb; Biester, Rosette; Brownlow, Janeese A; Harpaz-Rotem, Ilan; Gur, Ruben C

    2017-01-01

    Mild traumatic brain injuries (mild TBIs) resulting from exposure to Improvised Explosive Devices (IEDs) are highly prevalent among veterans of the wars in Iraq and Afghanistan. This exploratory study compared the neurocognitive performance of blast-exposed veterans with (n = 19) and without (n = 15) reported symptoms of mild TBI. All subjects had diagnoses of posttraumatic stress disorder (PTSD). Neurocognitive testing was administered using a well-established computerized battery, the Penn Computerized Neuropsychological Battery (CNB), and groups were well matched on age, race, education, and time since most recent blast exposure. Although differences were not observed on CNB accuracy scores, MANOVAs revealed slower processing speed in the mTBI group when answering correctly on tests of simple and sustained attention, with large effect sizes. Results suggest a potential speed-accuracy tradeoff in blast-related mild TBI, which should be further examined in larger samples.

  17. Computerized neurocognitive testing in the management of sport-related concussion: an update.

    PubMed

    Resch, Jacob E; McCrea, Michael A; Cullum, C Munro

    2013-12-01

    Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.

  18. Factor Structure and Incremental Validity of the Enhanced Computer- Administered Tests

    DTIC Science & Technology

    1992-07-01

    performance in the mechanical maintenance specialties. 14. SUBJECT TERMS Aptitude tests, ASVAB (Armed services vocational aptitude battery), CAT ...Code 11) Attn: Dir, Personnel Systems (Code 12) Attn: Dir, Testing Systems (Code 13) Attn: CAT /ASVABPMO FJB1 COMNAVCRUITCOM FT1 CNET V8 CG MCRD...test, a computerized adaptive testing version of the ASVAB ( CAT -ASVAB), the psychomotor portion of the General Aptitude Test Battery (GATB), and the

  19. Validation of a Paper and Pencil Test Battery for the Diagnosis of Minimal Hepatic Encephalopathy in Korea.

    PubMed

    Jeong, Jae Yoon; Jun, Dae Won; Bai, Daiseg; Kim, Ji Yean; Sohn, Joo Hyun; Ahn, Sang Bong; Kim, Sang Gyune; Kim, Tae Yeob; Kim, Hyoung Su; Jeong, Soung Won; Cho, Yong Kyun; Song, Do Seon; Kim, Hee Yeon; Jung, Young Kul; Yoon, Eileen L

    2017-09-01

    The aim of this study was to validate a new paper and pencil test battery to diagnose minimal hepatic encephalopathy (MHE) in Korea. A new paper and pencil test battery was composed of number connection test-A (NCT-A), number connection test-B (NCT-B), digit span test (DST), and symbol digit modality test (SDMT). The norm of the new test was based on 315 healthy individuals between the ages of 20 and 70 years old. Another 63 healthy subjects (n = 31) and cirrhosis patients (n = 32) were included as a validation cohort. All participants completed the new paper and pencil test, a critical flicker frequency (CFF) test and computerized cognitive function test (visual continuous performance test [CPT]). The scores on the NCT-A and NCT-B increased but those of DST and SDMT decreased according to age. Twelve of the cirrhotic patients (37.5%) were diagnosed with MHE based on the new paper and pencil test battery. The total score of the paper and pencil test battery showed good positive correlation with the CFF (r = 0.551, P < 0.001) and computerized cognitive function test. Also, this score was lower in patients with MHE compared to those without MHE (P < 0.001). Scores on the CFF (32.0 vs. 28.7 Hz, P = 0.028) and the computer base cognitive test decreased significantly in patients with MHE compared to those without MHE. Test-retest reliability was comparable. In conclusion, the new paper and pencil test battery including NCT-A, NCT-B, DST, and SDMT showed good correlation with neuropsychological tests. This new paper and pencil test battery could help to discriminate patients with impaired cognitive function in cirrhosis (registered at Clinical Research Information Service [CRIS], https://cris.nih.go.kr/cris, KCT0000955). © 2017 The Korean Academy of Medical Sciences.

  20. NEUROTOXICITY TESTING IN HUMAN POPULATIONS: WORKSHOP OVERVIEW

    EPA Science Inventory

    A workshop was held in October 1983 at Rougemont, NC to review strategies and methods for neurotoxicity testing in human populations. Behavioral and electrophysiological testing methods were discussed with a major focus on computerized test batteries. Brief reviews of test method...

  1. Cognitive Function Before and After Left Heart Catheterization.

    PubMed

    Scott, David A; Evered, Lisbeth; Maruff, Paul; MacIsaac, Andrew; Maher, Sarah; Silbert, Brendan S

    2018-03-10

    Hospital procedures have been associated with cognitive change in older patients. This study aimed to document the prevalence of mild cognitive impairment in individuals undergoing left heart catheterization (LHC) before the procedure and the incidence of cognitive decline to 3 months afterwards. We conducted a prospective, observational, clinical investigation of elderly participants undergoing elective LHC. Cognition was assessed using a battery of written tests and a computerized cognitive battery before the LHC and then at 3 months afterwards. The computerized tests were also administered at 24 hours (or discharge) and 7 days after LHC. A control group of 51 community participants was recruited to calculate cognitive decline using the Reliable Change Index. Of 437 participants, mild cognitive impairment was identified in 226 (51.7%) before the procedure. Computerized tests detected an incidence of cognitive decline of 10.0% at 24 hours and 7.5% at 7 days. At 3 months, written tests detected an incidence of cognitive decline of 13.1% and computerized tests detected an incidence of 8.5%. Cognitive decline at 3 months using written tests was associated with increasing age, whereas computerized tests showed cognitive decline was associated with baseline amnestic mild cognitive impairment, diabetes mellitus, and prior coronary stenting. More than half the patients aged >60 years presenting for LHC have mild cognitive impairment. LHC is followed by cognitive decline in 8% to 13% of individuals at 3 months after the procedure. Subtle cognitive decline both before and after LHC is common and may have important clinical implications. URL: www.anzctr.org.au. Unique identifier: ACTRN12607000051448. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  2. Patterns of Auditory Perception Skills in Children with Learning Disabilities: A Computer-Assisted Approach.

    ERIC Educational Resources Information Center

    Pressman, E.; And Others

    1986-01-01

    The auditory receptive language skills of 40 learning disabled (LD) and 40 non-disabled boys (all 7 - 11 years old) were assessed via computerized versions of subtests of the Goldman-Fristoe-Woodcock Auditory Skills Test Battery. The computerized assessment correctly identified 92.5% of the LD group and 65% of the normal control children. (DB)

  3. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    ERIC Educational Resources Information Center

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  4. Computerized screening for cognitive impairment in patients with COPD.

    PubMed

    Campman, Carlijn; van Ranst, Dirk; Meijer, Jan Willem; Sitskoorn, Margriet

    2017-01-01

    COPD is associated with cognitive impairment. These impairments should be diagnosed, but due to time- and budget-reasons, they are often not investigated. The aim of this study is to examine the viability of a brief computerized cognitive test battery, Central Nervous System Vital Signs (CNSVS), in COPD patients. Patients with COPD referred to tertiary pulmonary rehabilitation were included. Cognitive functioning of patients was assessed with CNSVS before pulmonary rehabilitation and compared with age-corrected CNSVS norms. CNSVS is a 30 minute computerized test battery that includes tests of verbal and visual memory, psychomotor speed, processing speed, cognitive flexibility, complex attention, executive functioning, and reaction time. CNSVS was fully completed by 205 (93.2%, 105 females, 100 males) of the total group of patients (n=220, 116 females, 104 males). Z -tests showed that COPD patients performed significantly worse than the norms on all CNSVS cognitive domains. Slightly more than half of the patients (51.8%) had impaired functioning on 1 or more cognitive domains. Patients without computer experience performed significantly worse on CNSVS than patients using the computer frequently. The completion rate of CNSVS was high and cognitive dysfunctions measured with this screening were similar to the results found in prior research, including paper and pen cognitive tests. These results support the viability of this brief computerized cognitive screening in COPD patients, that may lead to better care for these patients. Cognitive performance of patients with little computer experience should be interpreted carefully. Future research on this issue is needed.

  5. A candidate automated test battery for neuropsychological screening of airmen : design and preliminary validation.

    DOT National Transportation Integrated Search

    1992-02-01

    A panel of the American Medical Association convened by the Federal Aviation Administration recommended that a computerized test of cognitive function be developed that would detect significant cognitive impairments that might otherwise go unrecogniz...

  6. The Walter Reed performance assessment battery.

    PubMed

    Thorne, D R; Genser, S G; Sing, H C; Hegge, F W

    1985-01-01

    This paper describes technical details of a computerized psychological test battery designed for examining the effects of various state-variables on a representative sample of normal psychomotor, perceptual and cognitive tasks. The duration, number and type of tasks can be customized to different experimental needs, and then administered and analyzed automatically, at intervals as short as one hour. The battery can be run on either the Apple-II family of computers or on machines compatible with the IBM-PC.

  7. Validation of a Self-Administered Computerized System to Detect Cognitive Impairment in Older Adults

    PubMed Central

    Brinkman, Samuel D.; Reese, Robert J.; Norsworthy, Larry A.; Dellaria, Donna K.; Kinkade, Jacob W.; Benge, Jared; Brown, Kimberly; Ratka, Anna; Simpkins, James W.

    2015-01-01

    There is increasing interest in the development of economical and accurate approaches to identifying persons in the community who have mild, undetected cognitive impairments. Computerized assessment systems have been suggested as a viable approach to identifying these persons. The validity of a computerized assessment system for identification of memory and executive deficits in older individuals was evaluated in the current study. Volunteers (N = 235) completed a 3-hr battery of neuropsychological tests and a computerized cognitive assessment system. Participants were classified as impaired (n = 78) or unimpaired (n = 157) on the basis of the Mini Mental State Exam, Wechsler Memory Scale-III and the Trail Making Test (TMT), Part B. All six variables (three memory variables and three executive variables) derived from the computerized assessment differed significantly between groups in the expected direction. There was also evidence of temporal stability and concurrent validity. Application of computerized assessment systems for clinical practice and for identification of research participants is discussed in this article. PMID:25332303

  8. Brief cognitive and behavioral screening in children with new-onset epilepsy: a pilot feasibility trial.

    PubMed

    Triplett, Regina L; Asato, Miya R

    2015-01-01

    Minimal work has used psychometrically robust measures in a systematic fashion to identify and monitor children at risk for cognitive and behavioral comorbidities in current epilepsy care. We piloted a computerized cognitive battery and behavioral questionnaire for children with newly diagnosed epilepsy to determine clinical feasibility and acceptability to parents and patients. We recruited medication-naïve children (ages 8-17 years) with recent-onset seizures and typical developmental history from an outpatient child neurology clinic. Children completed the CNS Vital Signs computerized battery, whereas parents completed the Strengths and Difficulties Questionnaire. Post-test interviews with parents and patients were completed regarding the acceptability of the assessment procedures. Forty-four families were eligible, and 39 agreed to participate (89%). All assessments were completed in less than 45 minutes. Parents rated testing in clinic as convenient and important, expressing strong interest in the cognitive and behavioral impact of epilepsy and medication. Children also rated the testing procedure as acceptable and agreed that they would recommend it to peers. Our brief battery was tolerated and well received by children and their parents. Computerized testing of children along with a parent questionnaire is a psychometrically viable approach that is acceptable to families. Our protocol is time efficient for clinical use with the potential to detect early cognitive and behavioral difficulties related to epilepsy. Ongoing longitudinal study will provide further information regarding the success of our screening methods in monitoring for disease- or treatment-related changes. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Computerized screening for cognitive impairment in patients with COPD

    PubMed Central

    Campman, Carlijn; van Ranst, Dirk; Meijer, Jan Willem; Sitskoorn, Margriet

    2017-01-01

    Purpose COPD is associated with cognitive impairment. These impairments should be diagnosed, but due to time- and budget-reasons, they are often not investigated. The aim of this study is to examine the viability of a brief computerized cognitive test battery, Central Nervous System Vital Signs (CNSVS), in COPD patients. Patients and methods Patients with COPD referred to tertiary pulmonary rehabilitation were included. Cognitive functioning of patients was assessed with CNSVS before pulmonary rehabilitation and compared with age-corrected CNSVS norms. CNSVS is a 30 minute computerized test battery that includes tests of verbal and visual memory, psychomotor speed, processing speed, cognitive flexibility, complex attention, executive functioning, and reaction time. Results CNSVS was fully completed by 205 (93.2%, 105 females, 100 males) of the total group of patients (n=220, 116 females, 104 males). Z-tests showed that COPD patients performed significantly worse than the norms on all CNSVS cognitive domains. Slightly more than half of the patients (51.8%) had impaired functioning on 1 or more cognitive domains. Patients without computer experience performed significantly worse on CNSVS than patients using the computer frequently. Conclusion The completion rate of CNSVS was high and cognitive dysfunctions measured with this screening were similar to the results found in prior research, including paper and pen cognitive tests. These results support the viability of this brief computerized cognitive screening in COPD patients, that may lead to better care for these patients. Cognitive performance of patients with little computer experience should be interpreted carefully. Future research on this issue is needed. PMID:29089756

  10. Does familiarity with computers affect computerized neuropsychological test performance?

    PubMed

    Iverson, Grant L; Brooks, Brian L; Ashton, V Lynn; Johnson, Lynda G; Gualtieri, C Thomas

    2009-07-01

    The purpose of this study was to determine whether self-reported computer familiarity is related to performance on computerized neurocognitive testing. Participants were 130 healthy adults who self-reported whether their computer use was "some" (n = 65) or "frequent" (n = 65). The two groups were individually matched on age, education, sex, and race. All completed the CNS Vital Signs (Gualtieri & Johnson, 2006b) computerized neurocognitive battery. There were significant differences on 6 of the 23 scores, including scores derived from the Symbol-Digit Coding Test, Stroop Test, and the Shifting Attention Test. The two groups were also significantly different on the Psychomotor Speed (Cohen's d = 0.37), Reaction Time (d = 0.68), Complex Attention (d = 0.40), and Cognitive Flexibility (d = 0.64) domain scores. People with "frequent" computer use performed better than people with "some" computer use on some tests requiring rapid visual scanning and keyboard work.

  11. Preliminary evaluation of a micro-based repeated measures testing system

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  12. CAT Procedures for Passage-Based Tests.

    ERIC Educational Resources Information Center

    Thompson, Tony D.; Davey, Tim

    Methods to control the test construct and the efficiency of a computerized adaptive test (CAT) were studied in the context of a reading comprehension test given as a part of a battery of tests for college admission. A goal of the study was to create test scores that were interchangeable with those from a fixed form paper and pencil test. The first…

  13. Assessment of minimal hepatic encephalopathy (with emphasis on computerized psychometric tests).

    PubMed

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-02-01

    Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life, and driving accidents. The detection of MHE requires specialized testing because it cannot, by definition, be diagnosed on standard clinical examination. Psychometric and neurophysiologic techniques are often used to test for MHE. Paper-pencil psychometric batteries and computerized tests have proved useful in diagnosing MHE and predicting its outcomes. Neurophysiologic tests also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike. Testing strategies depend on the normative data available, patient comfort, and local expertise. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Measuring Attention in the Hemispheres: The Lateralized Attention Network Test (LANT)

    ERIC Educational Resources Information Center

    Greene, Deanna J.; Barnea, Anat; Herzberg, Kristin; Rassis, Anat; Neta, Maital; Raz, Amir; Zaidel, Eran

    2008-01-01

    The attention network test (ANT) is a brief computerized battery measuring three independent behavioral components of attention: Conflict resolution (ability to overcome distracting stimuli), spatial Orienting (the benefit of valid spatial pre-cues), and Alerting (the benefit of temporal pre-cues). Imaging, clinical, and behavioral evidence…

  15. Test-Taking Skills of High School Students with and without Learning Disabilities

    ERIC Educational Resources Information Center

    Lewandowski, Lawrence J.; Berger, Cassie; Lovett, Benjamin J.; Gordon, Michael

    2016-01-01

    This study assessed the test-taking skills of 776 high school students, 35 of whom were diagnosed with learning disabilities (LD). Students completed a computerized battery of timed reading tests as well as scales that assess test anxiety and test-taking perceptions. Students with LD obtained lower scores than the nondisabled group on all of the…

  16. Construction of a memory battery for computerized administration, using item response theory.

    PubMed

    Ferreira, Aristides I; Almeida, Leandro S; Prieto, Gerardo

    2012-10-01

    In accordance with Item Response Theory, a computer memory battery with six tests was constructed for use in the Portuguese adult population. A factor analysis was conducted to assess the internal structure of the tests (N = 547 undergraduate students). According to the literature, several confirmatory factor models were evaluated. Results showed better fit of a model with two independent latent variables corresponding to verbal and non-verbal factors, reproducing the initial battery organization. Internal consistency reliability for the six tests were alpha = .72 to .89. IRT analyses (Rasch and partial credit models) yielded good Infit and Outfit measures and high precision for parameter estimation. The potential utility of these memory tasks for psychological research and practice willbe discussed.

  17. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    PubMed

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  18. Attention impairment in childhood absence epilepsy: an impulsivity problem?

    PubMed

    Cerminara, Caterina; D'Agati, Elisa; Casarelli, Livia; Kaunzinger, Ivo; Lange, Klaus W; Pitzianti, Mariabernarda; Parisi, Pasquale; Tucha, Oliver; Curatolo, Paolo

    2013-05-01

    Although attention problems have often been described in children with childhood absence epilepsy (CAE), the use of different methodological approaches, neuropsychological tests, and heterogeneous experimental groups has prevented identification of the selective areas of attention deficit in this population. In this study, we investigated several components of attention in children with CAE using a unique computerized test battery for attention performance. Participants included 24 patients with CAE and 24 controls matched for age and sex. They were tested with a computerized test battery, which included the following tasks: selective attention, impulsivity, focused attention, divided attention, alertness, and vigilance. Compared with healthy controls, patients with CAE made more commission errors in the Go/No-Go task and more omission errors in the divided attention task. Childhood absence epilepsy patients also showed decreased reaction times in measures of selective attention and a great variability of reaction times in alertness and Go/No-Go tasks. Our findings suggest that patients with CAE were impaired in tonic and phasic alertness, divided attention, selective attention, and impulsivity. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Evaluation Plan for the Computerized Adaptive Vocational Aptitude Battery

    DTIC Science & Technology

    1982-05-15

    Educational and Psychological Tests published by the American Psychological Association, the American Educational Research Association, and the National...Psychometric Society Meetings, May 1981. References 71 American Psychological Association. Standards for educational and psychological tests . Washington, D.C...Methods Program, Dept. of Psychology , Uni- versity of Minnesota, MN, September, 1981. Koch, W.R. & Reckase, M.D. A live tailored testing comparison study

  20. Assessment of Minimal HE (with emphasis on computerized psychometric tests)

    PubMed Central

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-01-01

    Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464

  1. Development and Field Test of the Trial Battery for Project A

    DTIC Science & Technology

    1987-05-01

    cognitive, temperament, biographical data, and vocational interest) were investigated to detect excessive redundancy among the PB measures, especially ...abili- ties. The literature review procedures were described earlier. Almost no literature was available on computerized, especially microprocessor-driven...Lhese questions, and it is acknowledged that research is necessary to obtain answers, especially with micropro- cessor-driven testing methods. Phase 3

  2. Efficient Allocation of Attentional Resources in Patients with ADHD: Maturational Changes from Age 10 to 29

    ERIC Educational Resources Information Center

    Gualtieri, C. Thomas; Johnson, Lynda G.

    2006-01-01

    Background: It has been proposed that ADHD is an executive control disorder. Little is known however about the maturation of executive control in ADHD. Method: A cross-sectional study of ADHD patients compared to normal controls tested on a computerized neurocognitive test battery. Participants: 175 patients with ADHD, age 10 to 29, compared to…

  3. A Multisite, Randomized Controlled Clinical Trial of Computerized Cognitive Remediation Therapy for Schizophrenia.

    PubMed

    Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J

    2015-11-01

    The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  4. Predicting on-road assessment pass and fail outcomes in older drivers with cognitive impairment using a battery of computerized sensory-motor and cognitive tests.

    PubMed

    Hoggarth, Petra A; Innes, Carrie R H; Dalrymple-Alford, John C; Jones, Richard D

    2013-12-01

    To generate a robust model of computerized sensory-motor and cognitive test performance to predict on-road driving assessment outcomes in older persons with diagnosed or suspected cognitive impairment. A logistic regression model classified pass–fail outcomes of a blinded on-road driving assessment. Generalizability of the model was tested using leave-one-out cross-validation. Three specialist clinics in New Zealand. Drivers (n=279; mean age 78.4, 65% male) with diagnosed or suspected dementia, mild cognitive impairment, unspecified cognitive impairment, or memory problems referred for a medical driving assessment. A computerized battery of sensory-motor and cognitive tests and an on-road medical driving assessment. One hundred fifty-five participants (55.5%) received an on-road fail score. Binary logistic regression correctly classified 75.6% of the sample into on-road pass and fail groups. The cross-validation indicated accuracy of the model of 72.0% with sensitivity for detecting on-road fails of 73.5%, specificity of 70.2%, positive predictive value of 75.5%, and negative predictive value of 68%. The off-road assessment prediction model resulted in a substantial number of people who were assessed as likely to fail despite passing an on-road assessment and vice versa. Thus, despite a large multicenter sample, the use of off-road tests previously found to be useful in other older populations, and a carefully constructed and tested prediction model, off-road measures have yet to be found that are sufficiently accurate to allow acceptable determination of on-road driving safety of cognitively impaired older drivers. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  5. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    PubMed

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings. Aerosp Med Hum Perform. 2017; 88(8):722-729.

  6. What Makes a Good Student? How Emotions, Self-Regulated Learning, and Motivation Contribute to Academic Achievement

    ERIC Educational Resources Information Center

    Mega, Carolina; Ronconi, Lucia; De Beni, Rossana

    2014-01-01

    The authors propose a theoretical model linking emotions, self-regulated learning, and motivation to academic achievement. This model was tested with 5,805 undergraduate students. They completed the Self-Regulated Learning, Emotions, and Motivation Computerized Battery (LEM-B) composed of 3 self-report questionnaires: the Self-Regulated Learning…

  7. CBT for Nightmares in OEF/OIF Veterans

    DTIC Science & Technology

    2013-07-01

    Freedom (OIF) have significant psychological symptoms related to traumatic war zone exposure, including recurrent nightmares and other sleep disturbances...nightmares. Participants complete a battery of computerized neuropsychological tests at baseline and are stratified in their randomization to either...procedures were developed. Study supervisors, Drs. Philip Gehrman and Andrea Phelps , review treatment tapes, and weekly supervision calls with study

  8. A computerized test battery for the assessment of cardiovascular reactivity.

    PubMed

    Debski, T T; Kamarck, T W; Jennings, J R; Young, L W; Eddy, M J; Zhang, Y X

    1991-01-01

    Recent evidence has suggested a possible relationship between the tendency to exhibit excessive cardiovascular reactions during psychological challenge and the risk of cardiovascular disease. Valid techniques for reliably assessing such reactions are, however, minimally available. A test battery for the assessment of cardiovascular reactivity to experimental challenge is currently being developed at the University of Pittsburgh in conjunction with the University of Miami and Duke University. An IBM-AT compatible microcomputer is being used for the concurrent collection of physiological data and presentation of the laboratory stressors. Digitized cardiovascular data being collected include EKG, Impedance Cardiogram (ICG), phonocardiogram, and a peripheral pulse wave measure. Blood pressure readings are also being collected and stored on disk. The computer presents three challenging video games, each designed to elicit cardiovascular reactions. Processing programs are being used and developed for the standardized scoring of the digitized signals. To assist in epidemiological research a mobile testing unit has been assembled for the easy administration of the test battery in varying geographical locations. The test battery being developed will increase the feasibility of epidemiological and clinical assessment of stress-induced cardiovascular responses which may substantiate a link between reactivity and cardiovascular disease.

  9. Computerized Investigations of Battery Characteristics.

    ERIC Educational Resources Information Center

    Hinrichsen, P. F.

    2001-01-01

    Uses a computer interface to measure terminal voltage versus current characteristic of a variety of batteries, their series and parallel combinations, and the variation with discharge. The concept of an internal resistance demonstrates that current flows through the battery determine the efficiency and serve to introduce Thevenin's theorem.…

  10. Advanced nickel-hydrogen spacecraft battery development

    NASA Technical Reports Server (NTRS)

    Coates, Dwaine K.; Fox, Chris L.; Standlee, D. J.; Grindstaff, B. K.

    1994-01-01

    Eagle-Picher currently has several advanced nickel-hydrogen (NiH2) cell component and battery designs under development including common pressure vessel (CPV), single pressure vessel (SPV), and dependent pressure vessel (DPV) designs. A CPV NiH2 battery, utilizing low-cost 64 mm (2.5 in.) cell diameter technology, has been designed and built for multiple smallsat programs, including the TUBSAT B spacecraft which is currently scheduled (24 Nov. 93) for launch aboard a Russian Proton rocket. An advanced 90 mm (3.5 in.) NiH2 cell design is currently being manufactured for the Space Station Freedom program. Prototype 254 mm (10 in.) diameter SPV batteries are currently under construction and initial boilerplate testing has shown excellent results. NiH2 cycle life testing is being continued at Eagle-Picher and IPV cells have currently completed more than 89,000 accelerated LEO cycles at 15% DOD, 49,000 real-time LEO cycles at 30 percent DOD, 37,800 cycles under a real-time LEO profile, 30 eclipse seasons in accelerated GEO, and 6 eclipse seasons in real-time GEO testing at 75 percent DOD maximum. Nickel-metal hydride battery development is continuing for both aerospace and electric vehicle applications. Eagle-Picher has also developed an extensive range of battery evaluation, test, and analysis (BETA) measurement and control equipment and software, based on Hewlett-Packard computerized data acquisition/control hardware.

  11. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    PubMed

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (r mean  = .72; r factor_ score  = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  12. Vestibular Balance Deficits Following Head Injury: Recommendations Concerning Evaluation and Rehabilitation in the Military Setting

    DTIC Science & Technology

    2012-02-27

    audiogram, magnetic resonance imaging ( MRI ) scan, and a battery of neuro-vestibular tests, etc. (see appendix B). Many of the findings are detailed...bills108/s1217.html 19 E.g., driven by a laptop, tablet PC, or PDA.   42 The authors also considered testing needs immediately after referral (by the... MRI scan   72 Neuro-vestibular testing o Dynamic Computerized Postu rography o Rotat ional chair t est ing of gain, phase, and symmet ry o Step

  13. CBT for Nightmares in OEF/OIF Veterans

    DTIC Science & Technology

    2012-07-01

    OEF) and Operation Iraqi Freedom ( OIF) have significant psychological symptoms related to traumatic war zone exposure, includi ng recurrent...and assessed for PTSD and war zone-related nightmares. Participants complete a battery of computerized neuropsychological tests at baseline and are...rating procedures were developed, and these are being used. Study supervisors, Drs. Philip Gehrm an and Andrea Phelps , review treatment tapes, and

  14. CBT for Nightmares in OEF/OIF Veterans

    DTIC Science & Technology

    2014-07-01

    and Operation Iraqi Freedom (OIF) have significant psychological symptoms related to traumatic war zone exposure, including recurrent nightmares...assessed for PTSD and war zone-related nightmares. Participants completed a battery of computerized neuropsychological tests at baseline and were...collaborator in Australia, Dr. Andrea Phelps . We continued to work with the Philadelphia VAMC Information Security and Privacy officers as well as the

  15. Brain activation during neurocognitive testing using functional near-infrared spectroscopy in patients following concussion compared to healthy controls.

    PubMed

    Kontos, A P; Huppert, T J; Beluk, N H; Elbin, R J; Henry, L C; French, J; Dakan, S M; Collins, M W

    2014-12-01

    There is no accepted clinical imaging modality for concussion, and current imaging modalities including fMRI, DTI, and PET are expensive and inaccessible to most clinics/patients. Functional near-infrared spectroscopy (fNIRS) is a non-invasive, portable, and low-cost imaging modality that can measure brain activity. The purpose of this study was to compare brain activity as measured by fNIRS in concussed and age-matched controls during the performance of cognitive tasks from a computerized neurocognitive test battery. Participants included nine currently symptomatic patients aged 18-45 years with a recent (15-45 days) sport-related concussion and five age-matched healthy controls. The participants completed a computerized neurocognitive test battery while wearing the fNIRS unit. Our results demonstrated reduced brain activation in the concussed subject group during word memory, (spatial) design memory, digit-symbol substitution (symbol match), and working memory (X's and O's) tasks. Behavioral performance (percent-correct and reaction time respectively) was lower for concussed participants on the word memory, design memory, and symbol match tasks than controls. The results of this preliminary study suggest that fNIRS could be a useful, portable assessment tool to assess reduced brain activation and augment current approaches to assessment and management of patients following concussion.

  16. A novel approach to sports concussion assessment: Computerized multilimb reaction times and balance control testing.

    PubMed

    Vartiainen, Matti V; Holm, Anu; Lukander, Jani; Lukander, Kristian; Koskinen, Sanna; Bornstein, Robert; Hokkanen, Laura

    2016-01-01

    Mild traumatic brain injuries (MTBI) or concussions often result in problems with attention, executive functions, and motor control. For better identification of these diverse problems, novel approaches integrating tests of cognitive and motor functioning are needed. The aim was to characterize minor changes in motor and cognitive performance after sports-related concussions with a novel test battery, including balance tests and a computerized multilimb reaction time test. The cognitive demands of the battery gradually increase from a simple stimulus response to a complex task requiring executive attention. A total of 113 male ice hockey players (mean age = 24.6 years, SD = 5.7) were assessed before a season. During the season, nine concussed players were retested within 36 hours, four to six days after the concussion, and after the season. A control group of seven nonconcussed players from the same pool of players with comparable demographics were retested after the season. Performance was measured using a balance test and the Motor Cognitive Test battery (MotCoTe) with multilimb responses in simple reaction, choice reaction, inhibition, and conflict resolution conditions. The performance of the concussed group declined at the postconcussion assessment compared to both the baseline measurement and the nonconcussed controls. Significant changes were observed in the concussed group for the multilimb choice reaction and inhibition tests. Tapping and balance showed a similar trend, but no statistically significant difference in performance. In sports-related concussions, complex motor tests can be valuable additions in assessing the outcome and recovery. In the current study, using subtasks with varying cognitive demands, it was shown that while simple motor performance was largely unaffected, the more complex tasks induced impaired reaction times for the concussed subjects. The increased reaction times may reflect the disruption of complex and integrative cognitive function in concussions.

  17. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors.

    PubMed

    Hansen, Tor Ivar; Haferstrom, Elise Christina D; Brunner, Jan F; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49-.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability.

  18. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors

    PubMed Central

    Hansen, Tor Ivar; Haferstrom, Elise Christina D.; Brunner, Jan F.; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Introduction: Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. Method: A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Results: Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49–.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Conclusions: Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability. PMID:26009791

  19. Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.

    PubMed

    De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil

    2015-12-01

    This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.

  20. Computerized Maze Navigation and On-Road Performance by Drivers With Dementia

    PubMed Central

    Ott, Brian R.; Festa, Elena K.; Amick, Melissa M.; Grace, Janet; Davis, Jennifer D.; Heindel, William C.

    2012-01-01

    This study examined the ability of computerized maze test performance to predict the road test performance of cognitively impaired and normal older drivers. The authors examined 133 older drivers, including 65 with probable Alzheimer disease, 23 with possible Alzheimer disease, and 45 control subjects without cognitive impairment. Subjects completed 5 computerized maze tasks employing a touch screen and pointer as well as a battery of standard neuropsychological tests. Parameters measured for mazes included errors, planning time, drawing time, and total time. Within 2 weeks, subjects were examined by a professional driving instructor on a standardized road test modeled after the Washington University Road Test. Road test total score was significantly correlated with total time across the 5 mazes. This maze score was significant for both Alzheimer disease subjects and control subjects. One maze in particular, requiring less than 2 minutes to complete, was highly correlated with driving performance. For the standard neuropsychological tests, highest correlations were seen with Trail Making A (TrailsA) and the Hopkins Verbal Learning Tests Trial 1 (HVLT1). Multiple regression models for road test score using stepwise subtraction of maze and neuropsychological test variables revealed significant independent contributions for total maze time, HVLT1, and TrailsA for the entire group; total maze time and HVLT1 for Alzheimer disease subjects; and TrailsA for normal subjects. As a visual analog of driving, a brief computerized test of maze navigation time compares well to standard neuropsychological tests of psychomotor speed, scanning, attention, and working memory as a predictor of driving performance by persons with early Alzheimer disease and normal elders. Measurement of maze task performance appears to be useful in the assessment of older drivers at risk for hazardous driving. PMID:18287166

  1. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    PubMed

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  2. Neuropsychological profile in adult schizophrenia measured with the CMINDS.

    PubMed

    van Erp, Theo G M; Preda, Adrian; Turner, Jessica A; Callahan, Shawn; Calhoun, Vince D; Bustillo, Juan R; Lim, Kelvin O; Mueller, Bryon; Brown, Gregory G; Vaidya, Jatin G; McEwen, Sarah; Belger, Aysenil; Voyvodic, James; Mathalon, Daniel H; Nguyen, Dana; Ford, Judith M; Potkin, Steven G

    2015-12-30

    Schizophrenia neurocognitive domain profiles are predominantly based on paper-and-pencil batteries. This study presents the first schizophrenia domain profile based on the Computerized Multiphasic Interactive Neurocognitive System (CMINDS(®)). Neurocognitive domain z-scores were computed from computerized neuropsychological tests, similar to those in the Measurement and Treatment Research to Improve Cognition in Schizophrenia Consensus Cognitive Battery (MCCB), administered to 175 patients with schizophrenia and 169 demographically similar healthy volunteers. The schizophrenia domain profile order by effect size was Speed of Processing (d=-1.14), Attention/Vigilance (d=-1.04), Working Memory (d=-1.03), Verbal Learning (d=-1.02), Visual Learning (d=-0.91), and Reasoning/Problem Solving (d=-0.67). There were no significant group by sex interactions, but overall women, compared to men, showed advantages on Attention/Vigilance, Verbal Learning, and Visual Learning compared to Reasoning/Problem Solving on which men showed an advantage over women. The CMINDS can readily be employed in the assessment of cognitive deficits in neuropsychiatric disorders; particularly in large-scale studies that may benefit most from electronic data capture. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Examination of the Test-Retest Reliability of a Computerized Neurocognitive Test Battery.

    PubMed

    Nakayama, Yusuke; Covassin, Tracey; Schatz, Philip; Nogle, Sally; Kovan, Jeff

    2014-08-01

    Test-retest reliability is a critical issue in the utility of computer-based neurocognitive assessment paradigms employing baseline and postconcussion tests. Researchers have reported low test-retest reliability for the Immediate Post Concussion Assessment and Cognitive Testing (ImPACT) across an interval of 45 and 50 days. To re-examine the test-retest reliability of the ImPACT between baseline, 45 days, and 50 days. Descriptive laboratory study. Eighty-five physically active college students (51 male, 34 female) volunteered for this study. Participants completed the ImPACT as well as a 15-item memory test at baseline, 45 days, and 50 days. Intraclass correlation coefficients (ICCs) were calculated for ImPACT composite scores, and change scores were calculated using reliable change indices (RCIs) and regression-based methods (RBMs) at 80% and 95% confidence intervals (CIs). The respective ICCs for baseline to day 45, day 45 to day 50, baseline to day 50, and overall were as follows: verbal memory (0.76, 0.69, 0.65, and 0.78), visual memory (0.72, 0.66, 0.60, and 0.74), visual motor (processing) speed (0.87, 0.88, 0.85, and 0.91), and reaction time (0.67, 0.81, 0.71, and 0.80). All ICCs exceeded the threshold value of 0.60 for acceptable test-retest reliability. All cases fell well within the 80% CI for both the RCI and RBM, while 1% to 5% of cases fell outside the 95% CI for the RCI and 1% for the RBM. Results suggest that the ImPACT is a reliable neurocognitive test battery at 45 and 50 days after the baseline assessment. The current findings agree with those of other reliability studies that have reported acceptable ICCs across 30-day to 1-year testing intervals, and they support the utility of the ImPACT for the multidisciplinary approach to concussion management. This study suggests that the computerized neurocognitive test battery, ImPACT, is a reliable test for postconcussion serial assessments. However, when managing concussed athletes, the ImPACT should not be used as a stand-alone measure. © 2014 The Author(s).

  4. Brain activation during neurocognitive testing using functional near-infrared spectroscopy in patients following concussion compared to healthy controls

    PubMed Central

    Huppert, T. J.; Beluk, N. H.; Elbin, R. J.; Henry, L. C.; French, J.; Dakan, S. M.; Collins, M. W.

    2016-01-01

    There is no accepted clinical imaging modality for concussion, and current imaging modalities including fMRI, DTI, and PET are expensive and inaccessible to most clinics/ patients. Functional near-infrared spectroscopy (fNIRS) is a non-invasive, portable, and low-cost imaging modality that can measure brain activity. The purpose of this study was to compare brain activity as measured by fNIRS in concussed and age-matched controls during the performance of cognitive tasks from a computerized neurocognitive test battery. Participants included nine currently symptomatic patients aged 18–45 years with a recent (15–45 days) sport-related concussion and five age-matched healthy controls. The participants completed a computerized neurocognitive test battery while wearing the fNIRS unit. Our results demonstrated reduced brain activation in the concussed subject group during word memory, (spatial) design memory, digit-symbol substitution (symbol match), and working memory (X’s and O’s) tasks. Behavioral performance (percent-correct and reaction time respectively) was lower for concussed participants on the word memory, design memory, and symbol match tasks than controls. The results of this preliminary study suggest that fNIRS could be a useful, portable assessment tool to assess reduced brain activation and augment current approaches to assessment and management of patients following concussion. PMID:24477579

  5. Comparison of cognitive functioning as measured by the Ruff Figural Fluency Test and the CogState computerized battery within the LifeLines Cohort Study.

    PubMed

    Kuiper, Jisca S; Oude Voshaar, Richard C; Verhoeven, Floor E A; Zuidema, Sytse U; Smidt, Nynke

    2017-05-12

    The Ruff Figural Fluency Test (RFFT; a pencil and paper test) and the CogState (a computerized cognitive test battery) are well-validated and suitable tests to evaluate cognitive functioning in large observational studies at the population level. The LifeLines Cohort Study includes the RFFT as baseline measurement and incorporated the CogState as replacement for the RFFT at follow-up. It is unknown how these two tests relate to each other. Therefore, the aim of this study is to examine the correlation between the RFFT and the CogState and the impact of demographic characteristics on this association. A subcohort of the LifeLines Cohort Study, a large population based cohort study, participated in this study. Correlations between the RFFT and six subtasks of the CogState were examined. Subgroup analyses were performed to investigate the influence of age, education, and gender on the results. With sensitivity analyses we investigated the influence of computer experience and (physical) impairments. A total of 509 participants (mean age (SD): 53 years (14.6); range 18-87 years) participated in this study. All correlations between the RFFT and the CogState were statistically significant (except for the correlation between the RFFT error ratio and the CogState One Back Task), ranging from -0.39 to 0.28. Stratifying the analyses for age, education, and gender did not substantially affect our conclusions. Sensitivity analyses showed no substantial influence of level of computer experience or (physical) impairments. Correlations found in the present study were only weak to moderate, indicating that cognitive functioning measured by the RFFT does not measure the same components of cognitive functioning as six subtasks of the CogState. Computerized testing such as the CogState may be very well suited for large cohort studies to assess cognitive functioning in the general population and to identify cognitive changes as early as possible, as it is a less time- and labor intensive tool.

  6. Computer-based tools for assessing micro-longitudinal patterns of cognitive function in older adults.

    PubMed

    Brown, Laura J E; Adlam, Tim; Hwang, Faustina; Khadra, Hassan; Maclean, Linda M; Rudd, Bridey; Smith, Tom; Timon, Claire; Williams, Elizabeth A; Astell, Arlene J

    2016-08-01

    Patterns of cognitive change over micro-longitudinal timescales (i.e., ranging from hours to days) are associated with a wide range of age-related health and functional outcomes. However, practical issues of conducting high-frequency assessments make investigations of micro-longitudinal cognition costly and burdensome to run. One way of addressing this is to develop cognitive assessments that can be performed by older adults, in their own homes, without a researcher being present. Here, we address the question of whether reliable and valid cognitive data can be collected over micro-longitudinal timescales using unsupervised cognitive tests.In study 1, 48 older adults completed two touchscreen cognitive tests, on three occasions, in controlled conditions, alongside a battery of standard tests of cognitive functions. In study 2, 40 older adults completed the same two computerized tasks on multiple occasions, over three separate week-long periods, in their own homes, without a researcher present. Here, the tasks were incorporated into a wider touchscreen system (Novel Assessment of Nutrition and Ageing (NANA)) developed to assess multiple domains of health and behavior. Standard tests of cognitive function were also administered prior to participants using the NANA system.Performance on the two "NANA" cognitive tasks showed convergent validity with, and similar levels of reliability to, the standard cognitive battery in both studies. Completion and accuracy rates were also very high. These results show that reliable and valid cognitive data can be collected from older adults using unsupervised computerized tests, thus affording new opportunities for the investigation of cognitive.

  7. 1958-2008: 50 years of youth fitness tests in the United States.

    PubMed

    Morrow, James R; Zhu, Weimo; Franks, B Don; Meredith, Marilu D; Spain, Christine

    2009-03-01

    The AAHPER Youth Fitness Test, the first U.S. national fitness test, was published 50 years ago. The seminal work of Krause and Hirschland influenced the fitness world and continues to do so today. Important youth fitness test initiatives in the last half century are summarized. Key elements leading to continued interest in youth fitness testing at the start of the 21st century include (a) concerns about children and youth fitness levels, (b) AAHPER(D)-led youth fitness battery development, (c) differentiation between performance-related and health-related fitness testing, (d) the numerous youth fitness tests developed, (e) collaborative discussions on development and adoption of a unified national youth fitness battery, (f) computerization of youth fitness test results, (g) differentiation between norm-referenced and criterion-referenced evaluation of student results, and (h) concern about youth fitness levels (again, but with a focus on health). We have come full circle on youth fitness interests. This article summarizes the key youth fitness tests in the second half of the 20th century and projects future considerations.

  8. Subjective, but not Objective, Lingering Effects of Multiple Past Concussions in Adolescents

    PubMed Central

    McKay, Carly D.; Mrazik, Martin; Barlow, Karen M.; Meeuwisse, Willem H.; Emery, Carolyn A.

    2013-01-01

    Abstract The existing literature on lingering effects from concussions in children and adolescents is limited and mixed, and there are no clear answers for patients, clinicians, researchers, or policy makers. The purpose of this study was to examine whether there are lingering effects of past concussions in adolescent athletes. Participants in this study included 643 competitive Bantam and Midget hockey players (most elite 20% by division of play) between 13 and 17 years of age (mean age=15.5, SD=1.2). Concussion history at baseline assessment was retrospectively documented using a pre-season questionnaire (PSQ), which was completed at home by parents and players in advance of baseline testing. Players with English as a second language, self-reported attention or learning disorders, a concussion within 6 months of baseline, or suspected invalid test profiles were excluded from these analyses. Demographically adjusted standard scores for the five composites/domains and raw symptom ratings from the brief Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) computerized battery were analyzed. Adolescent athletes with one or two or more prior concussions did not have significantly worse neurocognitive functioning on ImPACT than did those with no previous concussions. There were significantly more symptoms reported in those with two or more prior concussions than in those with no or one prior concussion. Adolescents with multiple previous concussions had higher levels of baseline symptoms, but there were not group differences in neurocognitive functioning using this brief computerized battery. PMID:23560947

  9. Subjective, but not objective, lingering effects of multiple past concussions in adolescents.

    PubMed

    Brooks, Brian L; McKay, Carly D; Mrazik, Martin; Barlow, Karen M; Meeuwisse, Willem H; Emery, Carolyn A

    2013-09-01

    The existing literature on lingering effects from concussions in children and adolescents is limited and mixed, and there are no clear answers for patients, clinicians, researchers, or policy makers. The purpose of this study was to examine whether there are lingering effects of past concussions in adolescent athletes. Participants in this study included 643 competitive Bantam and Midget hockey players (most elite 20% by division of play) between 13 and 17 years of age (mean age=15.5, SD=1.2). Concussion history at baseline assessment was retrospectively documented using a pre-season questionnaire (PSQ), which was completed at home by parents and players in advance of baseline testing. Players with English as a second language, self-reported attention or learning disorders, a concussion within 6 months of baseline, or suspected invalid test profiles were excluded from these analyses. Demographically adjusted standard scores for the five composites/domains and raw symptom ratings from the brief Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) computerized battery were analyzed. Adolescent athletes with one or two or more prior concussions did not have significantly worse neurocognitive functioning on ImPACT than did those with no previous concussions. There were significantly more symptoms reported in those with two or more prior concussions than in those with no or one prior concussion. Adolescents with multiple previous concussions had higher levels of baseline symptoms, but there were not group differences in neurocognitive functioning using this brief computerized battery.

  10. Validation of Computerized Adaptive Testing in an Outpatient Non-academic Setting: the VOCATIONS Trial

    PubMed Central

    Achtyes, Eric Daniel; Halstead, Scott; Smart, LeAnn; Moore, Tara; Frank, Ellen; Kupfer, David J.; Gibbons, Robert

    2015-01-01

    Objective Computerized adaptive tests (CAT) provide an alternative to fixed-length assessments for diagnostic screening and severity measurement of psychiatric disorders. We sought to cross-sectionally validate a suite of computerized adaptive tests for mental health (CAT-MH) in a community psychiatric sample. Methods 145 adult psychiatric outpatients and controls were prospectively evaluated with CAT for depression, mania and anxiety symptoms, compared to gold-standard psychiatric assessments including: Structured Clinical Interview for DSM IV-TR (SCID), Hamilton Rating Scale for Depression (HAM-D25), Patient Health Questionnaire (PHQ-9), Center for Epidemiologic Studies Depression Scale (CES-D), and Global Assessment of Functioning (GAF). Results Sensitivity and specificity for the computerized adaptive diagnostic test for depression (CAD-MDD) were .96 and .64, respectively (.96 and 1.00 for major depression versus controls). CAT for depression severity (CAT-DI) correlated well to standard depression scales HAM-D25 (r=.79), PHQ-9 (r=.90), CES-D (r=.90) and had OR=27.88 for current SCID major depressive disorder diagnosis across its range. CAT for anxiety severity (CAT-ANX) correlated to HAM-D25 (r=.73), PHQ-9 (r=.78), CES-D (r=.81), and had OR=11.52 for current SCID generalized anxiety disorder diagnosis across its range. CAT for mania severity (CAT-MANIA) did not correlate well to HAM-D25 (r=.31), PHQ-9 (r=.37), CES-D (r=.39), but had an OR=11.56 for a current SCID bipolar diagnosis across its range. Participants found the CAT-MH suite of tests acceptable and easy to use, averaging 51.7 items and 9.4 minutes to complete the full battery. Conclusions Compared to current gold-standard diagnostic and assessment measures, CAT-MH provides an effective, rapidly-administered assessment of psychiatric symptoms. PMID:26030317

  11. Examining an Executive Function Battery for Use with Preschool Children with Disabilities

    ERIC Educational Resources Information Center

    Kuhn, Laura J.; Willoughby, Michael T.; Blair, Clancy B.; McKinnon, Rachel

    2017-01-01

    Performance-based assessments of EF for use with young children who have or are at risk for disabilities are lacking. The current study investigates the use of a computerized battery for children with subclinical behaviors (N = 846) across a variety of developmental disabilities and evaluates practical information about feasibility of task…

  12. Performance in normal subjects on a novel battery of driving-related sensory-motor and cognitive tests.

    PubMed

    Innes, Carrie R H; Jones, Richard D; Anderson, Tim J; Hollobon, Susan G; Dalrymple-Alford, John C

    2009-05-01

    Currently, there is no international standard for the assessment of fitness to drive for cognitively or physically impaired persons. A computerized battery of driving-related sensory-motor and cognitive tests (SMCTests) has been developed, comprising tests of visuoperception, visuomotor ability, complex attention, visual search, decision making, impulse control, planning, and divided attention. Construct validity analysis was conducted in 60 normal, healthy subjects and showed that, overall, the novel cognitive tests assessed cognitive functions similar to a set of standard neuropsychological tests. The novel tests were found to have greater perceived face validity for predicting on-road driving ability than was found in the equivalent standard tests. Test-retest stability and reliability of SMCTests measures, as well as correlations between SMCTests and on-road driving, were determined in a subset of 12 subjects. The majority of test measures were stable and reliable across two sessions, and significant correlations were found between on-road driving scores and measures from ballistic movement, footbrake reaction, hand-control reaction, and complex attention. The substantial face validity, construct validity, stability, and reliability of SMCTests, together with the battery's level of correlation with on-road driving in normal subjects, strengthen our confidence in the ability of SMCTests to detect and identify sensory-motor and cognitive deficits related to unsafe driving and increased risk of accidents.

  13. Application of a computer-based neurocognitive assessment battery in the elderly with and without hearing loss.

    PubMed

    Völter, Christiane; Götze, Lisa; Falkenstein, Michael; Dazert, Stefan; Thomas, Jan Peter

    2017-01-01

    Due to demographic changes, the number of people suffering not only from dementia illness but also from hearing impairment with the need for hearing rehabilitation have increased noticeably. Even with the association between hearing, age, and cognitive decline being well known, this issue has so far not played an important role in daily clinical Ear Nose Throat settings. The aim of the present study was to evaluate the use of a computer-based battery of tests of neurocognitive abilities in older patients with and without hearing loss. A total of 120 patients aged 50 years and older were enrolled in this prospective clinical study: 40 patients suffered from severe bilateral hearing loss and were tested before cochlear implantation and 80 patients showed normal hearing thresholds between 500 and 4,000 Hz bilaterally. The test battery covered a wide range of cognitive abilities such as long- and short-term memory, working memory (WM), attention, inhibition, and other executive functions. Individuals with severe depression or cognitive impairment were excluded. Hearing status was a significant predictor of performance on delayed recall ( P =0.0082) and verbal fluency after adjusting for age ( P =0.0016). Age predominantly impacted on inhibition ( P =0.0039) and processing speed ( P <0.0001), whereas WM measured by the Operation Span task (OSPAN) and the attention were influenced by both age and hearing. The battery of tests was feasible and practical for testing older patients without prior computer skills. A computerized neurocognitive assessment battery may be a suitable tool for the elderly in clinical practice. While it cannot replace a thorough neuropsychological examination, it may help to draw the line between cognitive and hearing impairment in the elderly and enable the development of individual strategies for hearing rehabilitation.

  14. Determining the Sensitivity of CAT-ASVAB (Computerized Adaptive Testing- Armed Services Vocational Aptitude Battery) Scores to Changes in Item Response Curves with the Medium of Administration

    DTIC Science & Technology

    1986-08-01

    most examinees. Therefore it appears psychometrically ac - ceptable for the CAT -ASVAB project to proceed without item recalibration based on...MEMORANDUM DETERMINING THE SENSITIVITY OF CAT -ASVAB SCORES TO CHANGES IN ITEM RESPONSE CURVES WITH THE MEDIUM OF ADMINISTRATION D. R. Divgi...Subj: Center for Naval Analyses Research Memorandum 86-189 End: (1) CNA Research Memorandum 86-189, "Determining the Sensitivity of CAT -ASVAB

  15. Evaluation of the validity of the Psychology Experiment Building Language tests of vigilance, auditory memory, and decision making.

    PubMed

    Piper, Brian; Mueller, Shane T; Talebzadeh, Sara; Ki, Min Jung

    2016-01-01

    Background. The Psychology Experimental Building Language (PEBL) test battery (http://pebl.sourceforge.net/) is a popular application for neurobehavioral investigations. This study evaluated the correspondence between the PEBL and the non-PEBL versions of four executive function tests. Methods. In one cohort, young-adults (N = 44) completed both the Conner's Continuous Performance Test (CCPT) and the PEBL CPT (PCPT) with the order counter-balanced. In a second cohort, participants (N = 47) completed a non-computerized (Wechsler) and a computerized (PEBL) Digit Span (WDS or PDS) both Forward and Backward. Participants also completed the Psychological Assessment Resources or the PEBL versions of the Iowa Gambling Task (PARIGT or PEBLIGT). Results. The between-test correlations were moderately high (reaction time r = 0.78, omission errors r = 0.65, commission errors r = 0.66) on the CPT. DS Forward was significantly greater than DS Backward on the WDS (p < .0005) and the PDS (p < .0005). The total WDS score was moderately correlated with the PDS (r = 0.56). The PARIGT and the PEBLIGTs showed a very similar pattern for response times across blocks, development of preference for Advantageous over Disadvantageous Decks, and Deck selections. However, the amount of money earned (score-loan) was significantly higher in the PEBLIGT during the last Block. Conclusions. These findings are broadly supportive of the criterion validity of the PEBL measures of sustained attention, short-term memory, and decision making. Select differences between workalike versions of the same test highlight how detailed aspects of implementation may have more important consequences for computerized testing than has been previously acknowledged.

  16. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    PubMed

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  17. Traditional neuropsychological correlates and reliability of the automated neuropsychological assessment metrics-4 battery for Parkinson's disease.

    PubMed

    Hawkins, Keith A; Jennings, Danna; Vincent, Andrea S; Gilliland, Kirby; West, Adrienne; Marek, Kenneth

    2012-08-01

    The automated neuropsychological assessment metrics battery-4 for PD offers the promise of a computerized approach to cognitive assessment. To assess its utility, the ANAM4-PD was administered to 72 PD patients and 24 controls along with a traditional battery. Reliability was assessed by retesting 26 patients. The cognitive efficiency score (CES; a global score) exhibited high reliability (r = 0.86). Constituent variables exhibited lower reliability. The CES correlated strongly with the traditional battery global score, but displayed weaker relationships to UPDRS scores than the traditional score. Multivariate analysis of variance revealed a significant difference between the patient and control groups in ANAM4-PD performance, with three ANAM4-PD tests, math, tower, and pursuit tracking, displaying sizeable differences. In discriminant analyses these variables were as effective as the total ANAM4-PD in classifying cases designated as impaired based on traditional variables. Principal components analyses uncovered fewer factors in the ANAM4-PD relative to the traditional battery. ANAM4-PD variables correlated at higher levels with traditional motor and processing speed variables than with untimed executive, intellectual or memory variables. The ANAM4-PD displays high global reliability, but variable subtest reliability. The battery assesses a narrower range of cognitive functions than traditional tests, and discriminates between patients and controls less effectively. Three ANAM4-PD tests, pursuit tracking, math, and tower performed as well as the total ANAM4-PD in classifying patients as cognitively impaired. These findings could guide the refinement of the ANAM4-PD as an efficient method of screening for mild to moderate cognitive deficits in PD patients. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Measuring the Performance of Attention Networks with the Dalhousie Computerized Attention Battery (DalCAB): Methodology and Reliability in Healthy Adults.

    PubMed

    Jones, Stephanie A H; Butler, Beverly C; Kintzel, Franziska; Johnson, Anne; Klein, Raymond M; Eskes, Gail A

    2016-01-01

    Attention is an important, multifaceted cognitive domain that has been linked to three distinct, yet interacting, networks: alerting, orienting, and executive control. The measurement of attention and deficits of attention within these networks is critical to the assessment of many neurological and psychiatric conditions in both research and clinical settings. The Dalhousie Computerized Attention Battery (DalCAB) was created to assess attentional functions related to the three attention networks using a range of tasks including: simple reaction time, go/no-go, choice reaction time, dual task, flanker, item and location working memory, and visual search. The current study provides preliminary normative data, test-retest reliability (intraclass correlations) and practice effects in DalCAB performance 24-h after baseline for healthy young adults (n = 96, 18-31 years). Performance on the DalCAB tasks demonstrated Good to Very Good test-retest reliability for mean reaction time, while accuracy and difference measures (e.g., switch costs, interference effects, and working memory load effects) were most reliable for tasks that require more extensive cognitive processing (e.g., choice reaction time, flanker, dual task, and conjunction search). Practice effects were common and pronounced at the 24-h interval. In addition, performance related to specific within-task parameters of the DalCAB sub-tests provides preliminary support for future formal assessment of the convergent validity of our interpretation of the DalCAB as a potential clinical and research assessment tool for measuring aspects of attention related to the alerting, orienting, and executive control networks.

  19. Supervision and computerized neurocognitive baseline test performance in high school athletes: an initial investigation.

    PubMed

    Kuhn, Andrew Warren; Solomon, Gary S

    2014-01-01

    Computerized neuropsychological testing batteries have provided a time-efficient and cost-efficient way to assess and manage the neurocognitive aspects of patients with sport-related concussion. These tests are straightforward and mostly self-guided, reducing the degree of clinician involvement required by traditional clinical neuropsychological paper-and-pencil tests. To determine if self-reported supervision status affected computerized neurocognitive baseline test performance in high school athletes. Retrospective cohort study. Supervised testing took place in high school computer libraries or sports medicine clinics. Unsupervised testing took place at the participant's home or another location with computer access. From 2007 to 2012, high school athletes across middle Tennessee (n = 3771) completed computerized neurocognitive baseline testing (Immediate Post-Concussion Assessment and Cognitive Testing [ImPACT]). They reported taking the test either supervised by a sports medicine professional or unsupervised. These athletes (n = 2140) were subjected to inclusion and exclusion criteria and then matched based on age, sex, and number of prior concussions. We extracted demographic and performance-based data from each de-identified baseline testing record. Paired t tests were performed between the self-reported supervised and unsupervised groups, comparing the following ImPACT baseline composite scores: verbal memory, visual memory, visual motor (processing) speed, reaction time, impulse control, and total symptom score. For differences that reached P < .05, the Cohen d was calculated to measure the effect size. Lastly, a χ(2) analysis was conducted to compare the rate of invalid baseline testing between the groups. All statistical tests were performed at the 95% confidence interval level. Self-reported supervised athletes demonstrated better visual motor (processing) speed (P = .004; 95% confidence interval [0.28, 1.52]; d = 0.12) and faster reaction time (P < .001; 95% confidence interval [-0.026, -0.014]; d = 0.21) composite scores than self-reported unsupervised athletes. Speed-based tasks were most affected by self-reported supervision status, although the effect sizes were relatively small. These data lend credence to the hypothesis that supervision status may be a factor in the evaluation of ImPACT baseline test scores.

  20. Sensorimotor Learning in a Computerized Athletic Training Battery.

    PubMed

    Krasich, Kristina; Ramger, Ben; Holton, Laura; Wang, Lingling; Mitroff, Stephen R; Gregory Appelbaum, L

    2016-01-01

    Sensorimotor abilities are crucial for performance in athletic, military, and other occupational activities, and there is great interest in understanding learning in these skills. Here, behavioral performance was measured over three days as twenty-seven participants practiced multiple sessions on the Nike SPARQ Sensory Station (Nike, Inc., Beaverton, Oregon), a computerized visual and motor assessment battery. Wrist-worn actigraphy was recorded to monitor sleep-wake cycles. Significant learning was observed in tasks with high visuomotor control demands but not in tasks of visual sensitivity. Learning was primarily linear, with up to 60% improvement, but did not relate to sleep quality in this normal-sleeping population. These results demonstrate differences in the rate and capacity for learning across perceptual and motor domains, indicating potential targets for sensorimotor training interventions.

  1. Cognition assessment using the NIH Toolbox

    PubMed Central

    Dikmen, Sureyya S.; Heaton, Robert K.; Tulsky, David S.; Zelazo, Philip D.; Bauer, Patricia J.; Carlozzi, Noelle E.; Slotkin, Jerry; Blitz, David; Wallner-Allen, Kathleen; Fox, Nathan A.; Beaumont, Jennifer L.; Mungas, Dan; Nowinski, Cindy J.; Richler, Jennifer; Deocampo, Joanne A.; Anderson, Jacob E.; Manly, Jennifer J.; Borosh, Beth; Havlik, Richard; Conway, Kevin; Edwards, Emmeline; Freund, Lisa; King, Jonathan W.; Moy, Claudia; Witt, Ellen; Gershon, Richard C.

    2013-01-01

    Cognition is 1 of 4 domains measured by the NIH Toolbox for the Assessment of Neurological and Behavioral Function (NIH-TB), and complements modules testing motor function, sensation, and emotion. On the basis of expert panels, the cognition subdomains identified as most important for health, success in school and work, and independence in daily functioning were Executive Function, Episodic Memory, Language, Processing Speed, Working Memory, and Attention. Seven measures were designed to tap constructs within these subdomains. The instruments were validated in English, in a sample of 476 participants ranging in age from 3 to 85 years, with representation from both sexes, 3 racial/ethnic categories, and 3 levels of education. This report describes the development of the Cognition Battery and presents results on test-retest reliability, age effects on performance, and convergent and discriminant construct validity. The NIH-TB Cognition Battery is intended to serve as a brief, convenient set of measures to supplement other outcome measures in epidemiologic and longitudinal research and clinical trials. With a computerized format and national standardization, this battery will provide a “common currency” among researchers for comparisons across a wide range of studies and populations. PMID:23479546

  2. Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.

    PubMed

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc

    2013-10-01

    To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.

  3. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    PubMed

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge after sedation.

  4. Evaluation of the validity of the Psychology Experiment Building Language tests of vigilance, auditory memory, and decision making

    PubMed Central

    Mueller, Shane T.; Talebzadeh, Sara; Ki, Min Jung

    2016-01-01

    Background. The Psychology Experimental Building Language (PEBL) test battery (http://pebl.sourceforge.net/) is a popular application for neurobehavioral investigations. This study evaluated the correspondence between the PEBL and the non-PEBL versions of four executive function tests. Methods. In one cohort, young-adults (N = 44) completed both the Conner’s Continuous Performance Test (CCPT) and the PEBL CPT (PCPT) with the order counter-balanced. In a second cohort, participants (N = 47) completed a non-computerized (Wechsler) and a computerized (PEBL) Digit Span (WDS or PDS) both Forward and Backward. Participants also completed the Psychological Assessment Resources or the PEBL versions of the Iowa Gambling Task (PARIGT or PEBLIGT). Results. The between-test correlations were moderately high (reaction time r = 0.78, omission errors r = 0.65, commission errors r = 0.66) on the CPT. DS Forward was significantly greater than DS Backward on the WDS (p < .0005) and the PDS (p < .0005). The total WDS score was moderately correlated with the PDS (r = 0.56). The PARIGT and the PEBLIGTs showed a very similar pattern for response times across blocks, development of preference for Advantageous over Disadvantageous Decks, and Deck selections. However, the amount of money earned (score–loan) was significantly higher in the PEBLIGT during the last Block. Conclusions. These findings are broadly supportive of the criterion validity of the PEBL measures of sustained attention, short-term memory, and decision making. Select differences between workalike versions of the same test highlight how detailed aspects of implementation may have more important consequences for computerized testing than has been previously acknowledged. PMID:27014512

  5. Investigations of a simulated geomagnetic field experienced by the International Space Station on attentional performance

    NASA Astrophysics Data System (ADS)

    Del Seppia, C.; Mezzasalma, L.; Messerotti, M.; Cordelli, A.; Ghione, S.

    2009-01-01

    We have previously reported that the exposure to an abnormal magnetic field simulating the one encountered by the International Space Station (ISS) orbiting around the Earth may enhance autonomic response to emotional stimuli. Here we report the results of the second part of that study which tested whether this field also affects cognitive functions. Twenty-four volunteers participated in the study, 12 exposed to the natural geomagnetic field and 12 to the magnetic field encountered by ISS. The test protocol consisted of a set of eight tests chosen from a computerized test battery for the assessment of attentional performance. The duration of exposure was 90 min. No effect of exposure to ISS magnetic field was observed on attentional performance.

  6. Stroop performance in multiple sclerosis: information processing, selective attention, or executive functioning?

    PubMed

    Macniven, J A B; Davis, C; Ho, M-Y; Bradshaw, C M; Szabadi, E; Constantinescu, C S

    2008-09-01

    Cognitive impairments in information processing speed, attention and executive functioning are widely reported in patients with multiple sclerosis (MS). Several studies have identified impaired performance on the Stroop test in people with MS, yet uncertainty remains over the cause of this phenomenon. In this study, 25 patients with MS were assessed with a neuropsychological test battery including a computerized Stroop test and a computerized test of information processing speed, the Graded Conditional Discrimination Tasks (GCDT). The patient group was compared with an individually age, sex and estimated premorbid IQ-matched healthy control group. The patients' reaction times (RTs) were significantly longer than those of the controls on all Stroop test trials and there was a significantly enhanced absolute (RT(incongruent)-RT(neutral)) and relative (100 x [RT(incongruent)-RT(neutral)]/RT(neutral)) Stroop interference effect for the MS group. The linear function relating RT to stimulus complexity in the GCDT was significantly steeper in the patient group, indicating slowed information processing. The results are discussed with reference to the difference engine model, a theory of diversity in speeded cognition. It is concluded that, in the assessment of people with MS, great caution must be used in the interpretation of performance on neuropsychological tests which rely on RT as the primary measure.

  7. Modulation of cognitive performance and mood by aromas of peppermint and ylang-ylang.

    PubMed

    Moss, Mark; Hewitt, Steven; Moss, Lucy; Wesnes, Keith

    2008-01-01

    This study provides further evidence for the impact of the aromas of plant essential oils on aspects of cognition and mood in healthy participants. One hundred and forty-four volunteers were randomly assigned to conditions of ylang-ylang aroma, peppermint aroma, or no aroma control. Cognitive performance was assessed using the Cognitive Drug Research computerized assessment battery, with mood scales completed before and after cognitive testing. The analysis of the data revealed significant differences between conditions on a number of the factors underpinning the tests that constitute the battery. Peppermint was found to enhance memory whereas ylang-ylang impaired it, and lengthened processing speed. In terms of subjective mood peppermint increased alertness and ylang-ylang decreased it, but significantly increased calmness. These results provide support for the contention that the aromas of essential oils can produce significant and idiosyncratic effects on both subjective and objective assessments of aspects of human behavior. They are discussed with reference to possible pharmacological and psychological modes of influence.

  8. Sensitivity and specificity of subacute computerized neurocognitive testing and symptom evaluation in predicting outcomes after sports-related concussion.

    PubMed

    Lau, Brian C; Collins, Michael W; Lovell, Mark R

    2011-06-01

    Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.

  9. A computerized aircraft battery servicing facility

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.

    1992-01-01

    The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.

  10. Development and Validation of the Cognition Test Battery for Spaceflight.

    PubMed

    Basner, Mathias; Savitt, Adam; Moore, Tyler M; Port, Allison M; McGuire, Sarah; Ecker, Adrian J; Nasrini, Jad; Mollicone, Daniel J; Mott, Christopher M; McCann, Thom; Dinges, David F; Gur, Ruben C

    2015-11-01

    Sustained high-level cognitive performance is of paramount importance for the success of space missions, which involve environmental, physiological, and psychological stressors that may affect brain functions. Despite subjective symptom reports of cognitive fluctuations in spaceflight, the nature of neurobehavioral functioning in space has not been clarified. We developed a computerized cognitive test battery (Cognition) that has sensitivity to multiple cognitive domains and was specifically designed for the high-performing astronaut population. Cognition consists of 15 unique forms of 10 neuropsychological tests that cover a range of cognitive domains, including emotion processing, spatial orientation, and risk decision making. Cognition is based on tests known to engage specific brain regions as evidenced by functional neuroimaging. Here we describe the first normative and acute total sleep deprivation data on the Cognition test battery as well as several efforts underway to establish the validity, sensitivity, feasibility, and acceptability of Cognition. Practice effects and test-retest variability differed substantially between the 10 Cognition tests, illustrating the importance of normative data that both reflect practice effects and differences in stimulus set difficulty in the population of interest. After one night without sleep, medium to large effect sizes were observed for 3 of the 10 tests addressing vigilant attention (Cohen's d = 1.00), cognitive throughput (d = 0.68), and abstract reasoning (d = 0.65). In addition to providing neuroimaging-based novel information on the effects of spaceflight on a range of cognitive functions, Cognition will facilitate comparing the effects of ground-based analogues to spaceflight, increase consistency across projects, and thus enable meta-analyses.

  11. Development and Validation of the Cognition Test Battery for Spaceflight

    PubMed Central

    Basner, Mathias; Savitt, Adam; Moore, Tyler M.; Port, Allison M.; McGuire, Sarah; Ecker, Adrian J.; Nasrini, Jad; Mollicone, Daniel J.; Mott, Christopher M.; McCann, Thom; Dinges, David F.; Gur, Ruben C.

    2015-01-01

    Background Sustained high-level cognitive performance is of paramount importance for the success of space missions, which involve environmental, physiological and psychological stressors that may affect brain functions. Despite subjective symptom reports of cognitive fluctuations in spaceflight, the nature of neurobehavioral functioning in space has not been clarified. Methods We developed a computerized cognitive test battery (Cognition) that has sensitivity to multiple cognitive domains and was specifically designed for the high-performing astronaut population. Cognition consists of 15 unique forms of 10 neuropsychological tests that cover a range of cognitive domains including emotion processing, spatial orientation, and risk decision making. Cognition is based on tests known to engage specific brain regions as evidenced by functional neuroimaging. Here we describe the first normative and acute total sleep deprivation data on the Cognition test battery as well as several efforts underway to establish the validity, sensitivity, feasibility, and acceptability of Cognition. Results Practice effects and test-retest variability differed substantially between the 10 Cognition tests, illustrating the importance of normative data that both reflect practice effects and differences in stimulus set difficulty in the population of interest. After one night without sleep, medium to large effect sizes were observed for 3 of the 10 tests addressing vigilant attention (Cohen’s d=1.00), cognitive throughput (d=0.68), and abstract reasoning (d=0.65). Conclusions In addition to providing neuroimaging-based novel information on the effects of spaceflight on a range of cognitive functions, Cognition will facilitate comparing the effects of ground-based analogs to spaceflight, increase consistency across projects, and thus enable meta-analyses. PMID:26564759

  12. Using the Cambridge Neuropsychological Test Automated Battery (CANTAB) to assess the cognitive impact of electroconvulsive therapy on visual and visuospatial memory.

    PubMed

    Falconer, D W; Cleland, J; Fielding, S; Reid, I C

    2010-06-01

    The cognitive impact of electroconvulsive therapy (ECT) is rarely measured systematically in everyday clinical practice even though patient and clinician acceptance is limited by its adverse affect on memory. If patients are tested it is often with simple paper and pencil tests of visual or verbal memory. There are no reported studies of computerized neuropsychological testing to assess the cognitive impact of ECT on visuospatial memory. Twenty-four patients with severe depression were treated with a course of bilateral ECT and assessed with a battery of visual memory tests within the Cambridge Neuropsychological Test Automated Battery (CANTAB). These included spatial and pattern recognition memory, pattern-location associative learning and a delayed matching to sample test. Testing was carried out before ECT, during ECT, within the week after ECT and 1 month after ECT. Patients showed significant impairments in visual and visuospatial memory both during and within the week after ECT. Most impairments resolved 1 month following ECT; however, significant impairment in spatial recognition memory remained. This is one of only a few studies that have detected anterograde memory deficits more than 2 weeks after treatment. Patients receiving ECT displayed a range of visual and visuospatial deficits over the course of their treatment. These deficits were most prominent for tasks dependent on the use of the right medial temporal lobe; frontal lobe function may also be implicated. The CANTAB appears to be a useful instrument for measuring the adverse cognitive effects of ECT on aspects of visual and visuospatial memory.

  13. Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

    NASA Technical Reports Server (NTRS)

    Wilkes, R. L.; Kennedy, R. S.; Dunlap, W. P.; Lane, N. E.

    1986-01-01

    A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.

  14. Investigations of a simulated geomagnetic field experienced by the International Space Station on attentional performance.

    PubMed

    Del Seppia, Cristina; Mezzasalma, Lorena; Messerotti, Mauro; Cordelli, Alessandro; Ghione, Sergio

    2009-01-01

    We have previously reported that the exposure to an abnormal magnetic field simulating the one encountered by the International Space Station (ISS) orbiting around the Earth may enhance autonomic response to emotional stimuli. Here we report the results of the second part of that study which tested whether this field also affects cognitive functions. Twenty-four volunteers participated in the study, 12 exposed to the natural geomagnetic field and 12 to the magnetic field encountered by ISS. The test protocol consisted of a set of eight tests chosen from a computerized test battery for the assessment of attentional performance. The duration of exposure was 90 min. No effect of exposure to ISS magnetic field was observed on attentional performance. (c) 2008 Wiley-Liss, Inc.

  15. A combination of physical activity and computerized brain training improves verbal memory and increases cerebral glucose metabolism in the elderly.

    PubMed

    Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N

    2014-12-02

    Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60-85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [(18)F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults.

  16. A combination of physical activity and computerized brain training improves verbal memory and increases cerebral glucose metabolism in the elderly

    PubMed Central

    Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N

    2014-01-01

    Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60–85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [18F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults. PMID:25463973

  17. Logistic regression function for detection of suspicious performance during baseline evaluations using concussion vital signs.

    PubMed

    Hill, Benjamin David; Womble, Melissa N; Rohling, Martin L

    2015-01-01

    This study utilized logistic regression to determine whether performance patterns on Concussion Vital Signs (CVS) could differentiate known groups with either genuine or feigned performance. For the embedded measure development group (n = 174), clinical patients and undergraduate students categorized as feigning obtained significantly lower scores on the overall test battery mean for the CVS, Shipley-2 composite score, and California Verbal Learning Test-Second Edition subtests than did genuinely performing individuals. The final full model of 3 predictor variables (Verbal Memory immediate hits, Verbal Memory immediate correct passes, and Stroop Test complex reaction time correct) was significant and correctly classified individuals in their known group 83% of the time (sensitivity = .65; specificity = .97) in a mixed sample of young-adult clinical cases and simulators. The CVS logistic regression function was applied to a separate undergraduate college group (n = 378) that was asked to perform genuinely and identified 5% as having possibly feigned performance indicating a low false-positive rate. The failure rate was 11% and 16% at baseline cognitive testing in samples of high school and college athletes, respectively. These findings have particular relevance given the increasing use of computerized test batteries for baseline cognitive testing and return-to-play decisions after concussion.

  18. The aerospace energy systems laboratory: Hardware and software implementation

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.; Oneil-Rood, Nora

    1989-01-01

    For many years NASA Ames Research Center, Dryden Flight Research Facility has employed automation in the servicing of flight critical aircraft batteries. Recently a major upgrade to Dryden's computerized Battery Systems Laboratory was initiated to incorporate distributed processing and a centralized database. The new facility, called the Aerospace Energy Systems Laboratory (AESL), is being mechanized with iAPX86 and iAPX286 hardware running iRMX86. The hardware configuration and software structure for the AESL are described.

  19. Performance on a computerized shopping task significantly predicts real world functioning in persons diagnosed with bipolar disorder.

    PubMed

    Laloyaux, Julien; Pellegrini, Nadia; Mourad, Haitham; Bertrand, Hervé; Domken, Marc-André; Van der Linden, Martial; Larøi, Frank

    2013-12-15

    Persons diagnosed with bipolar disorder often suffer from cognitive impairments. However, little is known concerning how these cognitive deficits impact their real world functioning. We developed a computerized real-life activity task, where participants are required to shop for a list of grocery store items. Twenty one individuals diagnosed with bipolar disorder and 21 matched healthy controls were administered the computerized shopping task. Moreover, the patient group was assessed with a battery of cognitive tests and clinical scales. Performance on the shopping task significantly differentiated patients and healthy controls for two variables: Total time to complete the shopping task and Mean time spent to consult the shopping list. Moreover, in the patient group, performance on these variables from the shopping task correlated significantly with cognitive functioning (i.e. processing speed, verbal episodic memory, planning, cognitive flexibility, and inhibition) and with clinical variables including duration of illness and real world functioning. Finally, variables from the shopping task were found to significantly explain 41% of real world functioning of patients diagnosed with bipolar disorder. These findings suggest that the shopping task provides a good indication of real world functioning and cognitive functioning of persons diagnosed with bipolar disorder. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Investigations of rhesus monkey video-task performance: evidence for enrichment

    NASA Technical Reports Server (NTRS)

    Washburn, D. A.; Rumbaugh, D. M.

    1992-01-01

    We have developed the Language Research Center's Computerized Test System (LRC-CTS) for psychological research. Basically, the LRC-CTS is a battery of software tasks--computerized versions of many of the classic testing paradigms of cognitive and comparative psychology--and the hardware required to administer them. An XT- or 386-compatible computer is connected to a color monitor, onto which computer-generated stimuli are presented. Sound feedback is delivered through an external speaker/amplifier, and a joystick is used as an input device. The animals reach through the mesh of their home cages to manipulate the joystick, which causes isomorphic movements of a cursor on the screen thereby allowing animals to respond according to the varied demands of the tasks. Correct responses are rewarded with a fruit-flavored chow pellet. Using this technology, we have trained and tested rhesus monkeys, a variety of apes, human adults, and normally developing or mentally retarded human children. Other labs using the LRC-CTS are beginning to report encouraging results with other monkey species as well. From this research, a number of interesting and important psychological findings have resulted. In the present paper, however, evidence will be reviewed which suggests that the LRC-CTS is an effective means of providing environmental enrichment to singly housed rhesus monkeys.

  1. Retinal nerve fiber layer thickness and neuropsychiatric manifestations in systemic lupus erythematosus.

    PubMed

    Shulman, S; Shorer, R; Wollman, J; Dotan, G; Paran, D

    2017-11-01

    Background Cognitive impairment is frequent in systemic lupus erythematosus. Atrophy of the corpus callosum and hippocampus have been reported in patients with systemic lupus erythematosus, and diffusion tensor imaging studies have shown impaired white matter integrity, suggesting that white matter damage in systemic lupus erythematosus may underlie the cognitive impairment as well as other neuropsychiatric systemic lupus erythematosus manifestations. Retinal nerve fiber layer thickness, as assessed by optical coherence tomography, has been suggested as a biomarker for white matter damage in neurologic disorders such as multiple sclerosis, Alzheimer's disease and Parkinson's disease. Retinal nerve fiber layer thinning may occur early, even in patients with mild clinical symptoms. Aim The objective of this study was to assess the association of retinal nerve fiber layer thickness, as a biomarker of white matter damage in systemic lupus erythematosus patients, with neuropsychiatric systemic lupus erythematosus manifestations, including cognitive impairment. Methods Twenty-one consecutive patients with systemic lupus erythematosus underwent neuropsychological testing using a validated computerized battery of tests as well as the Rey-Auditory verbal learning test. All 21 patients, as well as 11 healthy, age matched controls, underwent optical coherence tomography testing to assess retinal nerve fiber layer thickness. Correlations between retinal nerve fiber layer thickness and results in eight cognitive domains assessed by the computerized battery of tests as well as the Rey-Auditory verbal learning test were assessed in patients with systemic lupus erythematosus, with and without neuropsychiatric systemic lupus erythematosus, and compared to retinal nerve fiber layer thickness in healthy controls. Results No statistically significant correlation was found between retinal nerve fiber layer thickness in patients with systemic lupus erythematosus as compared to healthy controls. When evaluating by subgroups, no correlation was found between patients with or without neuropsychiatric systemic lupus erythematosus or cognitive impairment and retinal nerve fiber layer thickness. Conclusion Retinal nerve fiber layer thickness of systemic lupus erythematosus patients was not found to be statistically different compared to controls. Within systemic lupus erythematosus patients there was no correlation between retinal nerve fiber layer thickness and cognitive impairment or other neuropsychiatric systemic lupus erythematosus manifestations.

  2. Evaluation of the Waggoner Computerized Color Vision Test.

    PubMed

    Ng, Jason S; Self, Eriko; Vanston, John E; Nguyen, Andrew L; Crognale, Michael A

    2015-04-01

    Clinical color vision evaluation has been based primarily on the same set of tests for the past several decades. Recently, computer-based color vision tests have been devised, and these have several advantages but are still not widely used. In this study, we evaluated the Waggoner Computerized Color Vision Test (CCVT), which was developed for widespread use with common computer systems. A sample of subjects with (n = 59) and without (n = 361) color vision deficiency (CVD) were tested on the CCVT, the anomaloscope, the Richmond HRR (Hardy-Rand-Rittler) (4th edition), and the Ishihara test. The CCVT was administered in two ways: (1) on a computer monitor using its default settings and (2) on one standardized to a correlated color temperature (CCT) of 6500 K. Twenty-four subjects with CVD performed the CCVT both ways. Sensitivity, specificity, and correct classification rates were determined. The screening performance of the CCVT was good (95% sensitivity, 100% specificity). The CCVT classified subjects as deutan or protan in agreement with anomaloscopy 89% of the time. It generally classified subjects as having a more severe defect compared with other tests. Results from 18 of the 24 subjects with CVD tested under both default and calibrated CCT conditions were the same, whereas the results from 6 subjects had better agreement with other test results when the CCT was set. The Waggoner CCVT is an adequate color vision screening test with several advantages and appears to provide a fairly accurate diagnosis of deficiency type. Used in conjunction with other color vision tests, it may be a useful addition to a color vision test battery.

  3. NATURE OF BINDING INTERACTION OF SELECTED CHEMICALS WITH RAT ESTROGEN RECEPTORS

    EPA Science Inventory

    The US EPA is currently validating a rat uterine estrogen receptor (ER) binding assay as part of the Tier 1 Screening Battery for the Endocrine Disruptor Program. An eventual goal is to use interactive data to create computerized structure-activity models. However, more informati...

  4. Position requirements for space station personnel and linkages to portable microcomputer performance assessment

    NASA Technical Reports Server (NTRS)

    Jeanneret, P. R.

    1988-01-01

    The development and use of a menu of performance tests that can be self-administered on a portable microcomputer are investigated. In order to identify, develop, or otherwise select the relevant human capabilities/attributes to measure and hence include in the performance battery, it is essential that an analysis be conducted of the jobs or functions that will be performed throughout a space shuttle mission. The primary job analysis instrument, the Position Analysis Questionnaire (PAQ), is discussed in detail so the reader will have sufficient background for understanding the application of the instrument to the various work activities included within the scope of the study, and the derivation of the human requirements (abilities/attributes) from the PAQ analyses. The research methodology is described and includes the procedures used for gathering the PAQ data. The results are presented in detail with specific emphasis on identifying critical requirements that can be measured with a portable computerized assessment battery. A discussion of the results is given with implications for future research.

  5. Low Vision: Assessment and Training for Mobility.

    ERIC Educational Resources Information Center

    Dodds, Allan G.; Davis, Denis P.

    1987-01-01

    To develop a battery of tasks to predict and improve mobility performance, a series of functional vision tasks (texural shearing, degraded images, embedded figures, and parafoveal attention) were generated by a microcomputer. Sixty visually impaired subjects given either computerized task training or real-life training improved their low vision…

  6. Performance on a computerized neurocognitive battery in 22q11.2 deletion syndrome: A comparison between US and Israeli cohorts

    PubMed Central

    Yi, James J.; Weinberger, Ronnie; Moore, Tyler M.; Calkins, Monica E.; Guri, Yael; McDonald-McGinn, Donna M.; Zackai, Elaine H.; Emanuel, Beverly S.; Gur, Raquel E.; Gothelf, Doron; Gur, Ruben C.

    2016-01-01

    Increasingly, the effects of copy number variation (CNV) in the genome on brain function and behaviors are recognized as means to elucidate pathophysiology of psychiatric disorders. Such studies require large samples and we characterized the neurocognitive profile of two cohorts of individuals with 22q11.2 deletion syndrome (22q11DS), the most common CNV associated with schizophrenia, in an effort to harmonize phenotyping in multi-site global collaborations. The Penn Computerized Neurocognitive Battery (PCNB) was administered to individuals with 22q11DS in Philadelphia (PHL; n=155, aged 12–40) and Tel Aviv (TLV; n=59, aged 12–36). We examined effect sizes of performance differences between the cohorts and confirmed the factor structure of PCNB performance efficiency in the combined sample based on data from a large comparison community sample. The cohorts performed comparably with notable deficits in executive function, episodic memory and social cognition domains that were previously associated with abnormal neuroimaging findings in 22q11DS. In mixed model analysis, while there was a main effect for site for accuracy (number of correct response) and speed (time to correct response) independently, there were no main site effects for standardized efficiency (average of accuracy and speed). The fit of a structural model was excellent indicating that PCNB tests were related to the targeted cognitive domains. Thus, our results provide preliminary support for the use of the PCNB as an efficient tool for neurocognitive assessment in international 22q11DS collaborations. PMID:27200494

  7. Performance on a computerized neurocognitive battery in 22q11.2 deletion syndrome: A comparison between US and Israeli cohorts.

    PubMed

    Yi, James J; Weinberger, Ronnie; Moore, Tyler M; Calkins, Monica E; Guri, Yael; McDonald-McGinn, Donna M; Zackai, Elaine H; Emanuel, Beverly S; Gur, Raquel E; Gothelf, Doron; Gur, Ruben C

    2016-07-01

    Increasingly, the effects of copy number variation (CNV) in the genome on brain function and behaviors are recognized as means to elucidate pathophysiology of psychiatric disorders. Such studies require large samples and we characterized the neurocognitive profile of two cohorts of individuals with 22q11.2 deletion syndrome (22q11DS), the most common CNV associated with schizophrenia, in an effort to harmonize phenotyping in multi-site global collaborations. The Penn Computerized Neurocognitive Battery (PCNB) was administered to individuals with 22q11DS in Philadelphia (PHL; n=155, aged 12-40) and Tel Aviv (TLV; n=59, aged 12-36). We examined effect sizes of performance differences between the cohorts and confirmed the factor structure of PCNB performance efficiency in the combined sample based on data from a large comparison community sample. The cohorts performed comparably with notable deficits in executive function, episodic memory and social cognition domains that were previously associated with abnormal neuroimaging findings in 22q11DS. In mixed model analysis, while there was a main effect for site for accuracy (number of correct response) and speed (time to correct response) independently, there were no main site effects for standardized efficiency (average of accuracy and speed). The fit of a structural model was excellent indicating that PCNB tests were related to the targeted cognitive domains. Thus, our results provide preliminary support for the use of the PCNB as an efficient tool for neurocognitive assessment in international 22q11DS collaborations. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Analysis of internal and external validity criteria for a computerized visual search task: A pilot study.

    PubMed

    Richard's, María M; Introzzi, Isabel; Zamora, Eliana; Vernucci, Santiago

    2017-01-01

    Inhibition is one of the main executive functions, because of its fundamental role in cognitive and social development. Given the importance of reliable and computerized measurements to assessment inhibitory performance, this research intends to analyze the internal and external criteria of validity of a computerized conjunction search task, to evaluate the role of perceptual inhibition. A sample of 41 children (21 females and 20 males), aged between 6 and 11 years old (M = 8.49, SD = 1.47), intentionally selected from a private management school of Mar del Plata (Argentina), middle socio-economic level were assessed. The Conjunction Search Task from the TAC Battery, Coding and Symbol Search tasks from Wechsler Intelligence Scale for Children were used. Overall, results allow us to confirm that the perceptual inhibition task form TAC presents solid rates of internal and external validity that make a valid measurement instrument of this process.

  9. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    PubMed

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  10. Neuropsychological Construct Structure of a Brief Computerized Neuropsychological Battery: Windows Spaceflight Cognitive Assessment Tool (WinSCAT)

    DTIC Science & Technology

    2005-09-08

    active, or widespread skin conditions such as eczema, psoriasis or a bad sunburn, you will not be able to participate in the study. If you have a history...the following health conditions?" Flashbacks/ PTSD _Panic Attacks/Disorder _Schizophrenia _Anxiety/Depression _Substance Abuse _Bipolar Disorder/Manic

  11. Identifying Simple Numerical Stimuli: Processing Inefficiencies Exhibited by Arithmetic Learning Disabled Children.

    ERIC Educational Resources Information Center

    Koontz, Kristine L.; Berch, Daniel B.

    1996-01-01

    Children with arithmetic learning disabilities (n=16) and normally achieving controls (n=16) in grades 3-5 were administered a battery of computerized tasks. Memory spans for both letters and digits were found to be smaller among the arithmetic learning disabled children. Implications for teaching are discussed. (Author/CMS)

  12. Multitasking capacities in persons diagnosed with schizophrenia: a preliminary examination of their neurocognitive underpinnings and ability to predict real world functioning.

    PubMed

    Laloyaux, Julien; Van der Linden, Martial; Levaux, Marie-Noëlle; Mourad, Haitham; Pirri, Anthony; Bertrand, Hervé; Domken, Marc-André; Adam, Stéphane; Larøi, Frank

    2014-07-30

    Difficulties in everyday life activities are core features of persons diagnosed with schizophrenia and in particular during multitasking activities. However, at present, patients׳ multitasking capacities have not been adequately examined in the literature due to the absence of suitable assessment strategies. We thus recently developed a computerized real-life activity task designed to take into account the complex and multitasking nature of certain everyday life activities where participants are required to prepare a room for a meeting. Twenty-one individuals diagnosed with schizophrenia and 20 matched healthy controls completed the computerized task. Patients were also evaluated with a cognitive battery, measures of symptomatology and real world functioning. To examine the ecological validity, 14 other patients were recruited and were given the computerized version and a real version of the meeting preparation task. Results showed that performance on the computerized task was significantly correlated with executive functioning, pointing to the major implication of these cognitive processes in multitasking situations. Performance on the computerized task also significantly predicted up to 50% of real world functioning. Moreover, the computerized task demonstrated good ecological validity. These findings suggest the importance of evaluating multitasking capacities in patients diagnosed with schizophrenia in order to predict real world functioning. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. The BEVPS: A new test battery to assess visual perceptual and spatial processing abilities in 5-14 year-old children.

    PubMed

    Schmetz, Emilie; Rousselle, Laurence; Ballaz, Cécile; Detraux, Jean-Jacques; Barisnikov, Koviljka

    2017-06-20

    This study aims to examine the different levels of visual perceptual object recognition (early, intermediate, and late) defined in Humphreys and Riddoch's model as well as basic visual spatial processing in children using a new test battery (BEVPS). It focuses on the age sensitivity, internal coherence, theoretical validity, and convergent validity of this battery. French-speaking, typically developing children (n = 179; 5 to 14 years) were assessed using 15 new computerized subtests. After selecting the most age-sensitive tasks though ceiling effect and correlation analyses, an exploratory factorial analysis was run with the 12 remaining subtests to examine the BEVPS' theoretical validity. Three separate factors were identified for the assessment of the stimuli's basic features (F1, four subtests), view-dependent and -independent object representations (F2, six subtests), and basic visual spatial processing (F3, two subtests). Convergent validity analyses revealed positive correlations between F1 and F2 and the Beery-VMI visual perception subtest, while no such correlations were found for F3. Children's performances progressed until the age of 9-10 years in F1 and in view-independent representations (F2), and until 11-12 years in view-dependent representations (F2). However, no progression with age was observed in F3. Moreover, the selected subtests, present good-to-excellent internal consistency, which indicates that they provide reliable measures for the assessment of visual perceptual processing abilities in children.

  14. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults.

    PubMed

    Piper, Brian J; Mueller, Shane T; Geerken, Alexander R; Dixon, Kyle L; Kroliczak, Gregory; Olsen, Reid H J; Miller, Jeremy K

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18-22). Study II evaluated test-retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18-22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen's d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance.

  15. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    ERIC Educational Resources Information Center

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  16. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    PubMed Central

    Mueller, Shane T.; Geerken, Alexander R.; Dixon, Kyle L.; Kroliczak, Gregory; Olsen, Reid H.J.; Miller, Jeremy K.

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18–22). Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance. PMID:26713233

  17. Microcomputer Network for Computerized Adaptive Testing (CAT)

    DTIC Science & Technology

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  18. Computerized Classification Testing with the Rasch Model

    ERIC Educational Resources Information Center

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  19. Neuropsychological Measures in the Diagnosis of ADHD in Preschool: Can Developmental Research Inform Diagnostic Practice?

    PubMed

    Merkt, Julia; Siniatchkin, Michael; Petermann, Franz

    2016-03-22

    The diagnosis of ADHD in preschool is challenging. Behavioral ratings are less reliable, but the value of neuropsychological tests in the diagnosis of ADHD has been debated. This article provides an overview of neuropsychological measures utilized in preschoolers with ADHD (3-5 years). In addition, the manuscript discusses the extent to which these measures have been tested for their diagnostic capacity. The diagnostic utility of computerized continuous performance tests and working memory subtests from IQ-batteries has been demonstrated in a number of studies by assessing their psychometric properties, sensitivity, and specificity. However, findings from developmental and basic research attempting to describe risk factors that explain variance in ADHD show the most consistent associations of ADHD with measures of delay aversion. Results from developmental research could benefit studies that improve ADHD diagnosis at the individual level. It might be helpful to consider testing as a structured situation for behavioral observation by the clinician. © The Author(s) 2016.

  20. Is there an association between advanced paternal age and endophenotype deficit levels in schizophrenia?

    PubMed

    Tsuang, Debby; Esterberg, Michelle; Braff, David; Calkins, Monica; Cadenhead, Kristin; Dobie, Dorcas; Freedman, Robert; Green, Michael F; Greenwood, Tiffany; Gur, Raquel; Gur, Ruben; Horan, William; Lazzeroni, Laura C; Light, Gregory A; Millard, Steven P; Olincy, Ann; Nuechterlein, Keith; Seidman, Larry; Siever, Larry; Silverman, Jeremy; Stone, William; Sprock, Joyce; Sugar, Catherine; Swerdlow, Neal; Tsuang, Ming; Turetsky, Bruce; Radant, Allen

    2014-01-01

    The children of older fathers have increased risks of developing schizophrenia spectrum disorders, and among those who develop these disorders, those with older fathers present with more severe clinical symptoms. However, the influence of advanced paternal age on other important domains related to schizophrenia, such as quantitative endophenotype deficit levels, remains unknown. This study investigated the associations between paternal age and level of endophenotypic impairment in a well-characterized family-based sample from the Consortium on the Genetics of Schizophrenia (COGS). All families included at least one affected subject and one unaffected sibling. Subjects met criteria for schizophrenia (probands; n = 293) or were unaffected first-degree siblings of those probands (n = 382). Paternal age at the time of subjects' birth was documented. Subjects completed a comprehensive clinical assessment and a battery of tests that measured 16 endophenotypes. After controlling for covariates, potential paternal age-endophenotype associations were analyzed using one model that included probands alone and a second model that included both probands and unaffected siblings. Endophenotype deficits in the Identical Pairs version of the 4-digit Continuous Performance Test and in the Penn Computerized Neurocognitive Battery verbal memory test showed significant associations with paternal age. However, after correcting for multiple comparisons, no endophenotype was significantly associated with paternal age. These findings suggest that factors other than advanced paternal age at birth may account for endophenotypic deficit levels in schizophrenia.

  1. Executive function on the Psychology Experiment Building Language tests.

    PubMed

    Piper, Brian J; Li, Victoria; Eiwaz, Massarra A; Kobel, Yuliyana V; Benice, Ted S; Chu, Alex M; Olsen, Reid H J; Rice, Douglas Z; Gray, Hilary M; Mueller, Shane T; Raber, Jacob

    2012-03-01

    The measurement of executive function has a long history in clinical and experimental neuropsychology. The goal of the present report was to determine the profile of behavior across the lifespan on four computerized measures of executive function contained in the recently developed Psychology Experiment Building Language (PEBL) test battery http://pebl.sourceforge.net/ and evaluate whether this pattern is comparable to data previously obtained with the non-PEBL versions of these tests. Participants (N = 1,223; ages, 5-89 years) completed the PEBL Trail Making Test (pTMT), the Wisconsin Card Sort Test (pWCST; Berg, Journal of General Psychology, 39, 15-22, 1948; Grant & Berg, Journal of Experimental Psychology, 38, 404-411, 1948), the Tower of London (pToL), or a time estimation task (Time-Wall). Age-related effects were found over all four tests, especially as age increased from young childhood through adulthood. For several tests and measures (including pToL and pTMT), age-related slowing was found as age increased in adulthood. Together, these findings indicate that the PEBL tests provide valid and versatile new research tools for measuring executive functions.

  2. Aerospace Energy Systems Laboratory - Requirements and design approach

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.

    1988-01-01

    The NASA Ames/Dryden Flight Research Facility operates a mixed fleet of research aircraft employing NiCd batteries in a variety of flight-critical applications. Dryden's Battery Systems Laboratory (BSL), a computerized facility for battery maintenance servicing, has evolved over two decades into one of the most advanced facilities of its kind in the world. Recently a major BSL upgrade was initiated with the goal of modernization to provide flexibility in meeting the needs of future advanced projects. The new facility will be called the Aerospace Energy Systems Laboratory (AESL) and will employ distributed processing linked to a centralized data base. AESL will be both a multistation servicing facility and a research laboratory for the advancement of energy storage system maintenance techniques. This paper describes the baseline requirements for the AESL and the design approach being taken for its mechanization.

  3. Design considerations for advanced battery concepts

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.; Thaller, L. H.

    1986-01-01

    A mathematical representation for the charge and discharge of a sodium-sulfur cell is developed. These equations are then used as the basis for a computerized model to examine the effects of cell arrangement in the design of a large multi-kilowatt battery from a group of hypothetical individual cells with known variations in their ampere hour capacity and internal resistance. The cycling characteristics of 216 individual cells arranged in six different configurations are evaluated with the view towards minimizing the adverse effects that are introduced due to the stoichastic aspects of groupings of cells, as well as the possibility of cell failures in both the open and shorted mode. Although battery systems based on sodium-sulfur cells are described in this example, any of the newer electrochemical systems can be fitted into this framework by making appropriate modifications to the basic equations.

  4. Design considerations for advanced battery concepts

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.; Thaller, L. H.

    1986-01-01

    A mathematical representation for the charge and discharge of a sodium-sulfur cell is developed. These equations are then used as the basis for a computerized model to examine the effects of cell arrangement in the design of a large multi-kilowatt battery from a group of hypothetical individual cells with known variations in their ampere hour capacity and internal resistance. The cycling characteristics of 216 individual cells arranged in six different configurations are evaluated with the view towards minimizing the adverse effects that are introduced due to the stochastic aspects of groupings of cells, as well as the possibility of cell failures in both the open and shorted mode. Although battery systems based on sodium-sulfur cells are described in this example, any of the newer electrochemical systems can be fitted into this framework by making appropriate modifications to the basic equations.

  5. Computerized Adaptive Testing (CAT): A User Manual

    DTIC Science & Technology

    1984-03-12

    NPRDC TR 84-32 COMPUTERIZED ADAPTIVE TESTING ( CAT ): A USER MANUAL Susan Hardwick Lawrence Eastman Ross Cooper Rehab Group, Incorporated San...a ~EI’IOD COVIRED COMPUTERIZED ADAPTIVE TESTING ( CAT ) Final Report Aug 1981-June 1982 A USER MANUAL 1. ~l:l’t,ORMINCI ORCI. RE~ORT NUM.I:R 62-83...II nee• .. _, entl ldentll)’ ,,. llloclr _,.,) A joint-service effort is underway to develop a computerized adaptive testing ( CAT ) system and to

  6. The Relationship between Specific Cognitive Domains, Fear of Falling, and Falls in People with Multiple Sclerosis

    PubMed Central

    2014-01-01

    The primary aim was to examine the relationship between seven definite aspects of cognition measured by a computerized cognitive testing tool on the history falls in people with mild to moderate MS (PwMS). Secondary aims focused on whether cognition performance is correlated to fear of falling, walking velocity, and a patient-rated measure of walking ability. One hundred and one PwMS were included in the study analysis. Fifty-two had a history of at least one fall during the past year. Outcome measures included a computerized cognitive test battery designed to evaluate multiple cognitive domains, gait speed, and self-reported questionnaires; 12-item MS walking scale (MSWS-12); and Falls Efficacy Scale International. Significant differences between fallers and nonfallers were exhibited in attention and verbal function, scoring 7.5% (P = 0.013) and 6.2% (P = 0.05), respectively, below the parallel scores of the nonfallers. Attention was the only cognitive component significantly correlated with the MSWS-12 self-reported questionnaire. Fear of falling was significantly correlated with 6 (out of 7) definite cognitive variables. The present findings support the concept that when evaluating and attempting to reduce fall risk, emphasis should be placed not only on traditional fall risk factors like muscle strength and motor function, but also on cognitive function. PMID:25165694

  7. Normative accuracy and response time data for the computerized Benton Facial Recognition Test (BFRT-c).

    PubMed

    Rossion, Bruno; Michel, Caroline

    2018-03-16

    We report normative data from a large (N = 307) sample of young adult participants tested with a computerized version of the long form of the classical Benton Facial Recognition Test (BFRT; Benton & Van Allen, 1968). The BFRT-c requires participants to match a target face photograph to either one or three of six face photographs presented simultaneously. We found that the percent accuracy on the BFRT-c (81%-83%) was below ceiling yet well above chance level, with little interindividual variance in this typical population sample, two important aspects of a sensitive clinical test. Although the split-half reliability on response accuracy was relatively low, due to the large variability in difficulty across items, the correct response times measured in this version-completed in 3 min, on average-provide a reliable and critical complementary measure of performance at individual unfamiliar-face matching. In line with previous observations from other measures, females outperformed male participants at the BFRT-c, especially for female faces. In general, performance was also lower following lighting changes than following head rotations, in line with previous studies that have emphasized participants' limited ability to match pictures of unfamiliar faces with important variations in illumination. Overall, this normative data set supports the validity of the BFRT-c as a key component of a battery of tests to identify clinical impairments in individual face recognition, such as observed in acquired prosopagnosia. However, this analysis strongly recommends that researchers consider the full test results: Beyond global indexes of performance based on accuracy rates only, they should consider the time taken to match individual faces as well as the variability in performance across items.

  8. Challenges and opportunities for genomic developmental neuropsychology: examples from the Penn-Drexel collaborative battery.

    PubMed

    Gur, Ruben C; Irani, Farzin; Seligman, Sarah; Calkins, Monica E; Richard, Jan; Gur, Raquel E

    2011-08-01

    Genomics has been revolutionizing medicine over the past decade by offering mechanistic insights into disease processes and engendering the age of "individualized medicine." Because of the sheer number of measures generated by gene sequencing methods, genomics requires "Big Science" where large datasets on genes are analyzed in reference to electronic medical record data. This revolution has largely bypassed the behavioral neurosciences, mainly because of the paucity of behavioral data in medical records and the labor-intensity of available neuropsychological assessment methods. We describe the development and implementation of an efficient neuroscience-based computerized battery, coupled with a computerized clinical assessment procedure. This assessment package has been applied to a genomic study of 10,000 children aged 8-21, of whom 1000 also undergo neuroimaging. Results from the first 3000 participants indicate sensitivity to neurodevelopmental trajectories. Sex differences were evident, with females outperforming males in memory and social cognition domains, while for spatial processing males were more accurate and faster, and they were faster on simple motor tasks. The study illustrates what will hopefully become a major component of the work of clinical and research neuropsychologists as invaluable participants in the dawning age of Big Science neuropsychological genomics.

  9. Reaction Time is a Marker of Early Cognitive and Behavioral Alterations in Pure Cerebral Small Vessel Disease.

    PubMed

    Jouvent, Eric; Reyes, Sonia; De Guio, François; Chabriat, Hugues

    2015-01-01

    The assessment of early and subtle cognitive and behavioral effects of cerebral small vessel disease (SVD) requires specific and long-lasting evaluations performed by experienced neuropsychologists. Simpler tools would be helpful for daily clinical practice. To determine whether a simple reaction time task that lasts 5 minutes and can be performed without external supervision on any tablet or laptop can be used as a proxy of early cognitive and behavioral alterations in CADASIL (Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy), a monogenic form of pure SVD related to NOTCH3 mutations. Twenty-two genetically confirmed patients with CADASIL having preserved global cognitive abilities and without disability (MMSE >24 and modified Rankin's scale ≤1) were compared to 29 age-and-gender matched controls to determine group differences according to: 1) conventional neuropsychological and behavioral testing; 2) a computerized battery evaluating reaction time, processing speed, and executive functions. In a second step, correlations between reaction time and cognitive and behavioral alterations detected using both conventional and computerized testing were tested in patients. Reaction time was significantly higher in patients than in controls (mean in patients: 283 ms - in controls: 254 ms, p = 0.03). In patients, reaction time was significantly associated with conventional and chronometric tests of executive functions, working memory, and apathy. Reaction time obtained using a very simple task may serve as a proxy of early cognitive and behavioral alterations in SVD and could be easily used in daily clinical practice.

  10. An Application of the Rasch Model to Computerized Adaptive Testing.

    ERIC Educational Resources Information Center

    Wisniewski, Dennis R.

    Three questions concerning the Binary Search Method (BSM) of computerized adaptive testing were studied: (1) whether it provided a reliable and valid estimation of examinee ability; (2) its effect on examinee attitudes toward computerized adaptive testing and conventional paper-and-pencil testing; and (3) the relationship between item response…

  11. Technology and Language Testing. A Collection of Papers from the Annual Colloquium on Language Testing Research (7th, Princeton, New Jersey, April 6-9, 1985).

    ERIC Educational Resources Information Center

    Stansfield, Charles W., Ed.

    This collection of essays on measurement theory and language testing includes: "Computerized Adaptive Testing: Implications for Language Test Developers" (Peter Tung); "The Promise and Threat of Computerized Adaptive Assessment of Reading Comprehension" (Michael Canale); "Computerized Rasch Analysis of Item Bias in ESL…

  12. Computerized Dynamic Adaptive Tests with Immediately Individualized Feedback for Primary School Mathematics Learning

    ERIC Educational Resources Information Center

    Wu, Huey-Min; Kuo, Bor-Chen; Wang, Su-Chen

    2017-01-01

    In this study, a computerized dynamic assessment test with both immediately individualized feedback and adaptively property was applied to Mathematics learning in primary school. For evaluating the effectiveness of the computerized dynamic adaptive test, the performances of three types of remedial instructions were compared by a pre-test/post-test…

  13. Normative neurocognitive data for National Football League players: an initial compendium.

    PubMed

    Solomon, Gary S; Lovell, Mark R; Casson, Ira R; Viano, David C

    2015-03-01

    The use of clinical neuropsychological tests in the evaluation of National Football League (NFL) players has been ongoing for more than two decades. Prior research has demonstrated that the NFL population may perform differently than the general population on standard paper and pencil neuropsychological tests. Given the increased interest in the longitudinal and long-term assessment of neurocognitive functioning in this group of athletes, we reviewed the published neuropsychological literature in an attempt to compile an initial compendium of available normative data on paper and pencil as well as computerized neuropsychological tests for this group of football players. Thirteen published studies met the inclusion criteria, and the results are presented by athlete status (active vs. retired) and classified by neuropsychological domain. Suggestions for potential core batteries with this population are discussed, as are directions for future research. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Aerospace energy systems laboratory: Requirements and design approach

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.

    1988-01-01

    The NASA Ames-Dryden Flight Research Facility at Edwards, California, operates a mixed fleet of research aircraft employing nickel-cadmium (NiCd) batteries in a variety of flight-critical applications. Dryden's Battery Systems Laboratory (BSL), a computerized facility for battery maintenance servicing, has developed over two decades into one of the most advanced facilities of its kind in the world. Recently a major BSL upgrade was initiated with the goal of modernization to provide flexibility in meeting the needs of future advanced projects. The new facility will be called the Aerospace Energy Systems Laboratory (AESL) and will employ distributed processing linked to a centralized data base. AESL will be both a multistation servicing facility and a research laboratory for the advancement of energy storage system maintenance techniques. This paper describes the baseline requirements for the AESL and the design approach being taken for its mechanization.

  15. Specific Features of Executive Dysfunction in Alzheimer-Type Mild Dementia Based on Computerized Cambridge Neuropsychological Test Automated Battery (CANTAB) Test Results.

    PubMed

    Kuzmickienė, Jurgita; Kaubrys, Gintaras

    2016-10-08

    BACKGROUND The primary manifestation of Alzheimer's disease (AD) is decline in memory. Dysexecutive symptoms have tremendous impact on functional activities and quality of life. Data regarding frontal-executive dysfunction in mild AD are controversial. The aim of this study was to assess the presence and specific features of executive dysfunction in mild AD based on Cambridge Neuropsychological Test Automated Battery (CANTAB) results. MATERIAL AND METHODS Fifty newly diagnosed, treatment-naïve, mild, late-onset AD patients (MMSE ≥20, AD group) and 25 control subjects (CG group) were recruited in this prospective, cross-sectional study. The CANTAB tests CRT, SOC, PAL, SWM were used for in-depth cognitive assessment. Comparisons were performed using the t test or Mann-Whitney U test, as appropriate. Correlations were evaluated by Pearson r or Spearman R. Statistical significance was set at p<0.05. RESULTS AD and CG groups did not differ according to age, education, gender, or depression. Few differences were found between groups in the SOC test for performance measures: Mean moves (minimum 3 moves): AD (Rank Sum=2227), CG (Rank Sum=623), p<0.001. However, all SOC test time measures differed significantly between groups: SOC Mean subsequent thinking time (4 moves): AD (Rank Sum=2406), CG (Rank Sum=444), p<0.001. Correlations were weak between executive function (SOC) and episodic/working memory (PAL, SWM) (R=0.01-0.38) or attention/psychomotor speed (CRT) (R=0.02-0.37). CONCLUSIONS Frontal-executive functions are impaired in mild AD patients. Executive dysfunction is highly prominent in time measures, but minimal in performance measures. Executive disorders do not correlate with a decline in episodic and working memory or psychomotor speed in mild AD.

  16. The LIFE Cognition Study: design and baseline characteristics

    PubMed Central

    Sink, Kaycee M; Espeland, Mark A; Rushing, Julia; Castro, Cynthia M; Church, Timothy S; Cohen, Ronald; Gill, Thomas M; Henkin, Leora; Jennings, Janine M; Kerwin, Diana R; Manini, Todd M; Myers, Valerie; Pahor, Marco; Reid, Kieran F; Woolard, Nancy; Rapp, Stephen R; Williamson, Jeff D

    2014-01-01

    Observational studies have shown beneficial relationships between exercise and cognitive function. Some clinical trials have also demonstrated improvements in cognitive function in response to moderate–high intensity aerobic exercise; however, these have been limited by relatively small sample sizes and short durations. The Lifestyle Interventions and Independence for Elders (LIFE) Study is the largest and longest randomized controlled clinical trial of physical activity with cognitive outcomes, in older sedentary adults at increased risk for incident mobility disability. One LIFE Study objective is to evaluate the effects of a structured physical activity program on changes in cognitive function and incident all-cause mild cognitive impairment or dementia. Here, we present the design and baseline cognitive data. At baseline, participants completed the modified Mini Mental Status Examination, Hopkins Verbal Learning Test, Digit Symbol Coding, Modified Rey–Osterrieth Complex Figure, and a computerized battery, selected to be sensitive to changes in speed of processing and executive functioning. During follow up, participants completed the same battery, along with the Category Fluency for Animals, Boston Naming, and Trail Making tests. The description of the mild cognitive impairment/dementia adjudication process is presented here. Participants with worse baseline Short Physical Performance Battery scores (prespecified at ≤7) had significantly lower median cognitive test scores compared with those having scores of 8 or 9 with modified Mini Mental Status Examination score of 91 versus (vs) 93, Hopkins Verbal Learning Test delayed recall score of 7.4 vs 7.9, and Digit Symbol Coding score of 45 vs 48, respectively (all P<0.001). The LIFE Study will contribute important information on the effects of a structured physical activity program on cognitive outcomes in sedentary older adults at particular risk for mobility impairment. In addition to its importance in the area of prevention of cognitive decline, the LIFE Study will also likely serve as a model for exercise and other behavioral intervention trials in older adults. PMID:25210447

  17. Severity of Organized Item Theft in Computerized Adaptive Testing: A Simulation Study

    ERIC Educational Resources Information Center

    Yi, Qing; Zhang, Jinming; Chang, Hua-Hua

    2008-01-01

    Criteria had been proposed for assessing the severity of possible test security violations for computerized tests with high-stakes outcomes. However, these criteria resulted from theoretical derivations that assumed uniformly randomized item selection. This study investigated potential damage caused by organized item theft in computerized adaptive…

  18. Computerized Adaptive Assessment of Cognitive Abilities among Disabled Adults.

    ERIC Educational Resources Information Center

    Engdahl, Brian

    This study examined computerized adaptive testing and cognitive ability testing of adults with cognitive disabilities. Adult subjects (N=250) were given computerized tests on language usage and space relations in one of three administration conditions: paper and pencil, fixed length computer adaptive, and variable length computer adaptive.…

  19. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  20. Evaluation of an ontology-based system for computerized cognitive rehabilitation.

    PubMed

    Alloni, Anna; Quaglini, Silvana; Panzarasa, Silvia; Sinforiani, Elena; Bernini, Sara

    2018-07-01

    This paper describes the results of a randomized clinical trial about the effectiveness of a computerized rehabilitation treatment on a sample of 31 patients affected by Parkinson disease. Computerized exercises were administered by the therapists to the intervention group (n = 17) through the CoRe tool, which automatically generates a big variety of exercises leveraging on a stimuli set (words, sounds and images) organized into a dedicated ontology. A battery of standard neuropsychological tests was performed for patients' assessment at baseline, after the treatment (that lasted 1 month), and after 6 months from the treatment stop. The control group underwent a sham intervention. Results show a statistically significant clinical benefit from computerized rehabilitation with respect to sham treatment. For the intervention group, response time and response accuracy were integrated into a weighted score that accounts also for the specific cognitive burden of each exercise. Differently from the control group, the majority of patients in the intervention group showed an improvement in that score, more marked in the first week of treatment, and which lasts for the entire treatment period, which could account both for a quick learning effect and for an improvement of cognitive conditions. Good usability of CoRe, already observed in previous studies, was confirmed by the present trial, where the percentage of protocol completion in the intervention group is very high (all but one patient are above 90%). The CoRe system showed to be effective to improve some cognitive abilities in patients with Parkinson disease. However, after the end of the training, the benefit is hardly maintained over time. These findings support the implementation of CoRe in the clinical routine and the continuation of the treatment after discharge through the use of a homecare version of the system. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Computerized Adaptive Test (CAT) Applications and Item Response Theory Models for Polytomous Items

    ERIC Educational Resources Information Center

    Aybek, Eren Can; Demirtasli, R. Nukhet

    2017-01-01

    This article aims to provide a theoretical framework for computerized adaptive tests (CAT) and item response theory models for polytomous items. Besides that, it aims to introduce the simulation and live CAT software to the related researchers. Computerized adaptive test algorithm, assumptions of item response theory models, nominal response…

  2. Computerized Testing of Level III Associate Degree Nursing Students versus Paper and Pencil Testing Methods

    ERIC Educational Resources Information Center

    Gullo, Shirna R.

    2014-01-01

    Computerized testing may be one solution to enhance performance on the curricular Health Education Systems Inc. (HESI) exam and the National Council Licensure Exam for Registered Nurses (NCLEX-RN). Due to the integration of improved technological processes and procedures in healthcare for computerized documentation and electronicmedical records,…

  3. Is There an Association between Advanced Paternal Age and Endophenotype Deficit Levels in Schizophrenia?

    PubMed Central

    Tsuang, Debby; Esterberg, Michelle; Braff, David; Calkins, Monica; Cadenhead, Kristin; Dobie, Dorcas; Freedman, Robert; Green, Michael F.; Greenwood, Tiffany; Gur, Raquel; Gur, Ruben; Horan, William; Lazzeroni, Laura C.; Light, Gregory A.; Millard, Steven P.; Olincy, Ann; Nuechterlein, Keith; Seidman, Larry; Siever, Larry; Silverman, Jeremy; Stone, William; Sprock, Joyce; Sugar, Catherine; Swerdlow, Neal; Tsuang, Ming; Turetsky, Bruce; Radant, Allen

    2014-01-01

    The children of older fathers have increased risks of developing schizophrenia spectrum disorders, and among those who develop these disorders, those with older fathers present with more severe clinical symptoms. However, the influence of advanced paternal age on other important domains related to schizophrenia, such as quantitative endophenotype deficit levels, remains unknown. This study investigated the associations between paternal age and level of endophenotypic impairment in a well-characterized family-based sample from the Consortium on the Genetics of Schizophrenia (COGS). All families included at least one affected subject and one unaffected sibling. Subjects met criteria for schizophrenia (probands; n = 293) or were unaffected first-degree siblings of those probands (n = 382). Paternal age at the time of subjects’ birth was documented. Subjects completed a comprehensive clinical assessment and a battery of tests that measured 16 endophenotypes. After controlling for covariates, potential paternal age–endophenotype associations were analyzed using one model that included probands alone and a second model that included both probands and unaffected siblings. Endophenotype deficits in the Identical Pairs version of the 4-digit Continuous Performance Test and in the Penn Computerized Neurocognitive Battery verbal memory test showed significant associations with paternal age. However, after correcting for multiple comparisons, no endophenotype was significantly associated with paternal age. These findings suggest that factors other than advanced paternal age at birth may account for endophenotypic deficit levels in schizophrenia. PMID:24523888

  4. Executive dysfunction in bipolar disorder and borderline personality disorder.

    PubMed

    Gvirts, H Z; Braw, Y; Harari, H; Lozin, M; Bloch, Y; Fefer, K; Levkovitz, Y

    2015-11-01

    The boundary between bipolar disorder (BD) and borderline personality disorder is a controversial one. Despite the importance of the topic, few studies have directly compared these patient groups. The aim of the study was to compare the executive functioning profile of BD and BPD patients. Executive functioning (sustained attention, problem-solving, planning, strategy formation, cognitive flexibility and working memory) was assessed in BD (n=30) and BPD outpatients (n=32) using a computerized assessment battery (Cambridge Neuropsychological Test Automated Battery, CANTAB). The groups were compared to one another as well as to healthy controls. BD patients showed deficits in strategy formation and in planning (indicated by longer execution time in the ToL task) in comparison to BPD patients and healthy controls. BPD patients showed deficits in planning (short deliberation time in the ToL task) in comparison to BD patients and in comparison to healthy controls. In comparison to healthy controls, BPD patients displayed deficits in problem-solving. Differences in executive dysfunction between BD and BPD patients suggest that this cognitive dimension may be relevant for the clarification of the boundary between the disorders. Copyright © 2015. Published by Elsevier Masson SAS.

  5. An Analysis of Minimum System Requirements to Support Computerized Adaptive Testing.

    DTIC Science & Technology

    1986-09-01

    adaptive test ( CAT ); adaptive test ing A;4SRAC:’ (Continue on reverie of necessary and ident4f by block number) % This pape-r discusses the minimum system...requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing, establishes a set of...discusses the minimum system requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing

  6. Income, neural executive processes, and preschool children's executive control.

    PubMed

    Ruberry, Erika J; Lengua, Liliana J; Crocker, Leanna Harris; Bruce, Jacqueline; Upshaw, Michaela B; Sommerville, Jessica A

    2017-02-01

    This study aimed to specify the neural mechanisms underlying the link between low household income and diminished executive control in the preschool period. Specifically, we examined whether individual differences in the neural processes associated with executive attention and inhibitory control accounted for income differences observed in performance on a neuropsychological battery of executive control tasks. The study utilized a sample of preschool-aged children (N = 118) whose families represented the full range of income, with 32% of families at/near poverty, 32% lower income, and 36% middle to upper income. Children completed a neuropsychological battery of executive control tasks and then completed two computerized executive control tasks while EEG data were collected. We predicted that differences in the event-related potential (ERP) correlates of executive attention and inhibitory control would account for income differences observed on the executive control battery. Income and ERP measures were related to performance on the executive control battery. However, income was unrelated to ERP measures. The findings suggest that income differences observed in executive control during the preschool period might relate to processes other than executive attention and inhibitory control.

  7. Challenges and opportunities for genomic developmental neuropsychology: Examples from the Penn-Drexel collaborative battery

    PubMed Central

    Gur, Ruben C.; Irani, Farzin; Seligman, Sarah; Calkins, Monica E.; Richard, Jan; Gur, Raquel E.

    2014-01-01

    Genomics has been revolutionizing medicine over the past decade by offering mechanistic insights into disease processes and harboring the age of “individualized medicine.” Because of the sheer number of measures generated by gene sequencing methods, genomics requires “Big Science” where large datasets on genes are analyzed in reference to electronic medical record data. This revolution has largely bypassed the behavioral neurosciences, mainly because of the paucity of behavioral data in medical records and the labor intensity of available neuropsychological assessment methods. We describe the development and implementation of an efficient neuroscience-based computerized battery, coupled with a computerized clinical assessment procedure. This assessment package has been applied to a genomic study of 10,000 children aged 8-21, of whom 1000 also undergo neuroimaging. Results from the first 3000 participants indicate sensitivity to neurodevelopmental trajectories. Sex differences were evident, with females outperforming males in memory and social cognition domains, while for spatial processing males were more accurate and faster, and they were faster on simple motor tasks. The study illustrates what will hopefully become a major component of the work of clinical and research neuropsychologists as invaluable participants in the dawning age of Big Science neuropsychological genomics. PMID:21902564

  8. Cognitive and emotional biomarkers of melancholic depression: An iSPOT-D report.

    PubMed

    Day, Claire V; Gatt, Justine M; Etkin, Amit; DeBattista, Charles; Schatzberg, Alan F; Williams, Leanne M

    2015-05-01

    Depressed patients with melancholic features have distinct impairments in cognition and anhedonia, but it remains unknown whether these impairments can be quantified on neurocognitive biomarker tests of behavioral performance. We compared melancholic major depressive disorder (MDD) patients to non-melancholic MDD patients and controls on a neurocognitive test battery that assesses eight general and emotional cognitive domains including the hypothesized decision-making and reward-threat perception. MDD outpatients (n=1008) were assessed using a computerized battery of tests. MDD participants met DSM-IV criteria for MDD and had a score ≥16 on the 17-item Hamilton Rating Scale for Depression. Melancholic MDD was defined using the Mini-International Neuropsychiatric Interview and a psychomotor disturbance observer-rated CORE measure score >7. Controls were age- and gender-matched with no previous DSM-IV or significant medical history. Melancholic participants (33.7% of the MDD sample) exhibited significantly poorer performance than controls across each domain of cognitive function and for speed of emotion identification and implicit emotion priming. Compared to the non-melancholic group, specific disturbances were seen on tests of information speed, decision speed, and reward-relevant emotional processing of happy expressions, even after co-varying for symptom severity. Assessments were taken at only one medication-free time point. Reward was investigated using an emotional faces task. Melancholic MDD is distinguished by a specific neurocognitive marker profile consistent with reduced decision-making capacity under time demands and loss of reward sensitivity. This profile suggests an underlying deficit in mesolimbic-cortical circuitry for motivationally-directed behavior. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Computerized Diagnostic Testing: Problems and Possibilities.

    ERIC Educational Resources Information Center

    McArthur, David L.

    The use of computers to build diagnostic inferences is explored in two contexts. In computerized monitoring of liquid oxygen systems for the space shuttle, diagnoses are exact because they can be derived within a world which is closed. In computerized classroom testing of reading comprehension, programs deliver a constrained form of adaptive…

  10. Microcomputer Network for Computerized Adaptive Testing (CAT): Program Listing. Supplement.

    DTIC Science & Technology

    1984-03-01

    UMICROCOMPUTER NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ): PROGRAM LISTING in APPROVED FOR PUBLIC RELEASE;IDISTRIBUTION UNLIMITEDPs DTIC ’ Akf 3 0 1-d84...NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ).- PROGRAM LISTING , ,j Baldwin Quan Thomas A. Park Gary Sandahl John H. Wolfe Reviewed by James R. McBride A...Center San Diego, California 92152 V.% :-, CONTENTrS Page CATPROJECT.TEXT CAT system driver textfile I 1 ADMINDIR- Subdirectory - Test administration

  11. Computerized Adaptive Screening Test (CAST): Development for Use in Military Recruiting Stations

    DTIC Science & Technology

    1984-01-01

    testing ( CAT ) 20. ABSTRACT (Continuo on rover .. efdo II neco .. ., ond Identity bJ’ 11/oclr -llor) The Computerized Adaptive Screening Test (CAST...effort is in progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the military entrance...U.S. Marine Corps) has been designated as lead service for CAT system development; and the Navy Personnel Research and Development Center, as lead

  12. Development of a Computerized Data Base to Monitor Wheeled Vehicle Corrosion

    DTIC Science & Technology

    1989-10-01

    the region which corrodes. This potential difference , or voltage of these little batteries or cells, is due to the difference in the oxygen...availability at the point of attack. Differential aeration cells occur at all places where there is a difference in the availability of oxygen and can only...program is actually an evaluation of the various corrosion prevention systems and methods which were applied to the wheeled vehicles when they were

  13. Contrasting group analysis of Brazilian students with dyslexia and good readers using the computerized reading and writing assessment battery “BALE”

    PubMed Central

    Toledo Piza, Carolina M. J.; de Macedo, Elizeu C.; Miranda, Monica C.; Bueno, Orlando F. A.

    2014-01-01

    The analysis of cognitive processes underpinning reading and writing skills may help to distinguish different reading ability profiles. The present study used a Brazilian reading and writing battery to compare performance of students with dyslexia with two individually matched control groups: one contrasting on reading competence but not age and the other group contrasting on age but not reading competence. Participants were 28 individuals with dyslexia (19 boys) with a mean age of 9.82 (SD ± 1.44) drawn from public and private schools. These were matched to: (1) an age control group (AC) of 26 good readers with a mean age of 9.77 (SD ± 1.44) matched by age, sex, years of schooling, and type of school; (2) reading control group (RC) of 28 younger controls with a mean age of 7.82 (SD ± 1.06) matched by sex, type of school, and reading level. All groups were tested on four tasks from the Brazilian Reading and Writing Assessment battery (“BALE”): Written Sentence Comprehension Test (WSCT); Spoken Sentence Comprehension Test (OSCT); Picture-Print Writing Test (PPWT 1.1-Writing); and the Reading Competence Test (RCT). These tasks evaluate reading and listening comprehension for sentences, spelling, and reading isolated words and pseudowords (non-words). The dyslexia group scored lower and took longer to complete tasks than the AC group. Compared with the RC group, there were no differences in total scores on reading or oral comprehension tasks. However, dyslexics presented slower reading speeds, longer completion times, and lower scores on spelling tasks, even compared with younger controls. Analysis of types of errors on word and pseudoword reading items showed students with dyslexia scoring lower for pseudoword reading than the other two groups. These findings suggest that the dyslexics overall scores were similar to those of younger readers. However, specific phonological and visual decoding deficits showed that the two groups differ in terms of underpinning reading strategies. PMID:25132829

  14. One-year vestibular and balance outcomes of Oklahoma City bombing survivors.

    PubMed

    Van Campen, L E; Dennis, J M; King, S B; Hanlin, R C; Velderman, A M

    1999-10-01

    This multisite investigation assessed subjective, behavioral, and objective balance function in 30 blast survivors. Subjects with vertigo, dizziness, or imbalance were screened (n = 6) or evaluated (n = 27) during 1 year. Tests included a questionnaire, electronystagmography (ENG), and computerized dynamic posturography (CDP). Ninety-seven percent of subjects were located inside a building during the blast, and 63 percent of subjects experienced dysequilibrium within 48 hours. Forty-three percent of symptoms could not be attributed to head injury. Sixty percent of subjects had abnormal ENG and/or CDP; ENG abnormalities mostly were peripheral or nonlocalizing, whereas CDP patterns were "vestibular," "surface dependent," and "physiologically inconsistent." At 1-year postblast, 55 percent of initially abnormal CDP results were normal, and 72 percent of subjects said symptoms were unchanged or occurred intermittently. A serial, test battery approach is recommended to assess symptoms. Blast-related dysequilibrium had clinically significant manifestations and should be considered a valid component of aural blast injury.

  15. Language Research Center's Computerized Test System (LRC-CTS) - Video-formatted tasks for comparative primate research

    NASA Technical Reports Server (NTRS)

    Rumbaugh, Duane M.; Washburn, David A.; Savage-Rumbaugh, E. S.; Hopkins, William D.; Richardson, W. K.

    1991-01-01

    Automation of a computerized test system for comparative primate research is shown to improve the results of learning in standard paradigms. A mediational paradigm is used to determine the degree to which criterion in the learning-set testing reflects stimulus-response associative or mediational learning. Rhesus monkeys are shown to exhibit positive transfer as the criterion levels are shifted upwards, and the effectiveness of the computerized testing system is confirmed.

  16. Computer-assisted rehabilitation of attention in pediatric multiple sclerosis and ADHD patients: a pilot trial.

    PubMed

    Simone, Marta; Viterbo, Rosa Gemma; Margari, Lucia; Iaffaldano, Pietro

    2018-06-08

    The treatment of cognitive deficits is challenging in pediatric onset multiple sclerosis (POMS) and in patients with attention deficit hyperactivity disorder (ADHD). We performed a pilot double-blind RCT to evaluate the efficacy of a home-based computerized-program for retraining attention in two cohorts of POMS and ADHD patients. POMS and ADHD patients failing in at least 2/4 attention tests on a neuropsychological battery were randomized to specific or nonspecific computerized training (ST, nST), performed in one-hour sessions, twice/week for 3 months. The primary outcome was the effect of the training on global neuropsychological performances measured by the cognitive impairment index (CII). The efficacy of the intervention was evaluated in each disease group by using repeated measures ANOVA. Sixteen POMS (9 females, age 15.75 ± 1.74 years) and 20 ADHD (2 females, age 11.19 ± 2.49 years) patients were enrolled. In POMS patients the ST exposure was associated to a significantly more pronounced improvement of the CII (p < 0.0001) and on cognitive test exploring attention, concentration, planning strategies and visuo-spatial memory performances in comparison to nST exposure. In ADHD patients the difference between the ST and nST on the CII was not statistical significant (p = 0.06), but a greater effect of the ST was found only on cognitive test exploring attention and delayed recall of visuo-spatial memory performances. Our data suggest that a cognitive rehabilitation program that targets attention is a suitable tool for improving global cognitive functioning in POMS patients, whereas it has a less pronounced transfer effect in ADHD patients. ClinicalTrials.gov; NCT03190902 ; registration date: June 15, 2017; retrospectively registered.

  17. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  18. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  19. Psychomotor and cognitive effects of piribedil, a dopamine agonist, in young healthy volunteers.

    PubMed

    Schück, Stéphane; Bentué-Ferrer, Danièle; Kleinermans, Diane; Reymann, Jean-Michel; Polard, Elisabeth; Gandon, Jean-Marc; Allain, Hervé

    2002-02-01

    Piribedil is a dopamine agonist acting on D2 and D3 central nervous system dopamine receptors. This drug has been administered to 12 young healthy male volunteers (age 22 +/- 2 years) according to a single center randomized, double-blind, two ways cross-over, placebo controlled trial, including a washout period of one week. Placebo and piribedil were administered by a single intravenous infusion over 2 h (3 mg). Psychomotor performance and cognitive functions were assessed through a standardized and computerized psychometric tests battery and a continuous electroencephalogram (EEG) mapping. Piribedil improved simple reaction time (P=0.02), immediate (P=0.045 and 0.004), and delayed free recall (P=0.05), dual coding test (P=0.02) and increased theta and fast beta waves on the EEG (P < 0.05 and 0.001, respectively). No deleterious effect was observed on the tests exploring attention and concentration via the other procedures. It is concluded that a single intravenous perfusion of piribedil 3 mg improves alertness and the information processing speed within the central nervous system, in healthy volunteers.

  20. The electrochemical fluorination of polymeric materials for high energy density aqueous and non-aqueous battery and fuel cell separators

    NASA Technical Reports Server (NTRS)

    Liu, C. C.

    1983-01-01

    A computerized system was established and the electrochemical fluorination of trichloroethylene, polyacrylic acid and polyvinyl alcohol in anhydrous hydrogen fluoride was attempted. Both solid substrates as well as membranes were used. Some difficulties were found in handling and analyzing the solid substrates and membranes. Further studies are needed in this area. A microprocessor aided electrochemical fluorination system capable of obtaining highly reproducible experimental results was established.

  1. Termination Criteria for Computerized Classification Testing

    ERIC Educational Resources Information Center

    Thompson, Nathan A.

    2011-01-01

    Computerized classification testing (CCT) is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as "pass" and "fail." Like adaptive testing for point estimation of ability, the key component is the…

  2. The Role of Gender in Neuropsychological Assessment in Healthy Adolescents.

    PubMed

    Mormile, Megan Elizabeth Evelyn; Langdon, Jody L; Hunt, Tamerah Nicole

    2018-01-01

    Research in college athletes has revealed significant gender differences in areas of verbal memory, visual memory, and reaction time. Additionally, research has focused on differences in neuropsychological components and gender in college populations; however, such differences in gender have not been documented in healthy adolescent populations. To identify potential differences between males and females using different components of a common computerized neuropsychological test. A computerized neuropsychological test battery (ImPACT®) was administered to 662 high-school age adolescent athletes (male: n = 451 female: n = 262). Differences between genders were calculated using a 1-way ANOVA. All statistical analyses were conducted using SPSS 23.0. Significance levels were set a priori at P < .05. A 1-way ANOVA revealed statistically significant differences between males and females for composite reaction time (F 1,660  = 10.68, P = .001) and total symptom score (F 1,660  = 81.20, P < .001). However, no statistically significant differences were found between males and females in composite verbal memory, visual memory, visual motor, or impulse control (P > .05). Significant differences between males and females were discovered for composite reaction time and total symptom scores, with females reporting more symptoms and slower reaction times at a baseline assessment. Increased symptom reporting by females may be attributed to both hormonal differences and increased honesty. Quicker reaction times in males may support theories that repetition of activities and quicker muscle contraction are gender dependent. However, additional research is necessary to understand gender differences in adolescent athletes during periods of cognitive and physical maturation.

  3. Computerized Adaptive Testing for Polytomous Motivation Items: Administration Mode Effects and a Comparison with Short Forms

    ERIC Educational Resources Information Center

    Hol, A. Michiel; Vorst, Harrie C. M.; Mellenbergh, Gideon J.

    2007-01-01

    In a randomized experiment (n = 515), a computerized and a computerized adaptive test (CAT) are compared. The item pool consists of 24 polytomous motivation items. Although items are carefully selected, calibration data show that Samejima's graded response model did not fit the data optimally. A simulation study is done to assess possible…

  4. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    NASA Technical Reports Server (NTRS)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  5. A new color vision test to differentiate congenital and acquired color vision defects.

    PubMed

    Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak

    2007-07-01

    To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.

  6. Zingiber officinale Improves Cognitive Function of the Middle-Aged Healthy Women

    PubMed Central

    Saenghong, Naritsara; Wattanathorn, Jintanaporn; Muchimapura, Supaporn; Tongun, Terdthai; Piyavhatkul, Nawanant; Banchonglikitkul, Chuleratana; Kajsongkram, Tanwarat

    2012-01-01

    The development of cognitive enhancers from plants possessing antioxidants has gained much attention due to the role of oxidative stress-induced cognitive impairment. Thus, this study aimed to determine the effect of ginger extract, or Zingiber officinale, on the cognitive function of middle-aged, healthy women. Sixty participants were randomly assigned to receive a placebo or standardized plant extract at doses of 400 and 800 mg once daily for 2 months. They were evaluated for working memory and cognitive function using computerized battery tests and the auditory oddball paradigm of event-related potentials at three different time periods: before receiving the intervention, one month, and two months. We found that the ginger-treated groups had significantly decreased P300 latencies, increased N100 and P300 amplitudes, and exhibited enhanced working memory. Therefore, ginger is a potential cognitive enhancer for middle-aged women. PMID:22235230

  7. Evaluating Content Alignment in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wise, Steven L.; Kingsbury, G. Gage; Webb, Norman L.

    2015-01-01

    The alignment between a test and the content domain it measures represents key evidence for the validation of test score inferences. Although procedures have been developed for evaluating the content alignment of linear tests, these procedures are not readily applicable to computerized adaptive tests (CATs), which require large item pools and do…

  8. Learning effect of computerized cognitive tests in older adults

    PubMed Central

    de Oliveira, Rafaela Sanches; Trezza, Beatriz Maria; Busse, Alexandre Leopold; Jacob-Filho, Wilson

    2014-01-01

    ABSTRACT Objective: To evaluate the learning effect of computerized cognitive testing in the elderly. Methods: Cross-sectional study with 20 elderly, 10 women and 10 men, with average age of 77.5 (±4.28) years. The volunteers performed two series of computerized cognitive tests in sequence and their results were compared. The applied tests were: Trail Making A and B, Spatial Recognition, Go/No Go, Memory Span, Pattern Recognition Memory and Reverse Span. Results: Based on the comparison of the results, learning effects were observed only in the Trail Making A test (p=0.019). Other tests performed presented no significant performance improvements. There was no correlation between learning effect and age (p=0.337) and education (p=0.362), as well as differences between genders (p=0.465). Conclusion: The computerized cognitive tests repeated immediately afterwards, for elderly, revealed no change in their performance, with the exception of the Trail Making test, demonstrating high clinical applicability, even in short intervals. PMID:25003917

  9. Item Pocket Method to Allow Response Review and Change in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2013-01-01

    Most computerized adaptive testing (CAT) programs do not allow test takers to review and change their responses because it could seriously deteriorate the efficiency of measurement and make tests vulnerable to manipulative test-taking strategies. Several modified testing methods have been developed that provide restricted review options while…

  10. The Effects of Test Difficulty Manipulation in Computerized Adaptive Testing and Self-Adapted Testing.

    ERIC Educational Resources Information Center

    Ponsoda, Vicente; Olea, Julio; Rodriguez, Maria Soledad; Revuelta, Javier

    1999-01-01

    Compared easy and difficult versions of self-adapted tests (SAT) and computerized adapted tests. No significant differences were found among the tests for estimated ability or posttest state anxiety in studies with 187 Spanish high school students, although other significant differences were found. Discusses implications for interpreting test…

  11. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    PubMed

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.

  12. Balancing Flexible Constraints and Measurement Precision in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Moyer, Eric L.; Galindo, Jennifer L.; Dodd, Barbara G.

    2012-01-01

    Managing test specifications--both multiple nonstatistical constraints and flexibly defined constraints--has become an important part of designing item selection procedures for computerized adaptive tests (CATs) in achievement testing. This study compared the effectiveness of three procedures: constrained CAT, flexible modified constrained CAT,…

  13. Suitcase Communicator

    NASA Technical Reports Server (NTRS)

    1984-01-01

    A joint development of Ames Research Center and General Electric Company, Schenectady, NY has produced a portable communications system designed to relay messages over long distances by satellite. It consists of a collapsible antenna and computerized transceiver, and a terminal for sending and receiving messages. The whole system fits into two Pullman size suit cases, and is powered from a conventional outlet or a vehicle's battery. Principal use is communications in disasters and other emergencies where it is necessary to get short but vital messages out of the emergency area.

  14. The Aerospace Energy Systems Laboratory: A BITBUS networking application

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.; Oneill-Rood, Nora

    1989-01-01

    The NASA Ames-Dryden Flight Research Facility developed a computerized aircraft battery servicing facility called the Aerospace Energy Systems Laboratory (AESL). This system employs distributed processing with communications provided by a 2.4-megabit BITBUS local area network. Customized handlers provide real time status, remote command, and file transfer protocols between a central system running the iRMX-II operating system and ten slave stations running the iRMX-I operating system. The hardware configuration and software components required to implement this BITBUS application are required.

  15. Solving Infeasibility Problems in Computerized Test Assembly.

    ERIC Educational Resources Information Center

    Timminga, Ellen

    1998-01-01

    Discusses problems of diagnosing and repairing infeasible linear-programming models in computerized test assembly. Demonstrates that it is possible to localize the causes of infeasibility, although this is not always easy. (SLD)

  16. Developing Computerized Tests for Classroom Teachers: A Pilot Study.

    ERIC Educational Resources Information Center

    Glowacki, Margaret L.; And Others

    Two types of computerized testing have been defined: (1) computer-based testing, using a computer to administer conventional tests in which all examinees take the same set of items; and (2) adaptive tests, in which items are selected for administration by the computer, based on examinee's previous responses. This paper discusses an option for…

  17. The Role of Item Feedback in Self-Adapted Testing.

    ERIC Educational Resources Information Center

    Roos, Linda L.; And Others

    1997-01-01

    The importance of item feedback in self-adapted testing was studied by comparing feedback and no feedback conditions for computerized adaptive tests and self-adapted tests taken by 363 college students. Results indicate that item feedback is not necessary to realize score differences between self-adapted and computerized adaptive testing. (SLD)

  18. An Introduction to the Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Tian, Jian-quan; Miao, Dan-min; Zhu, Xia; Gong, Jing-jing

    2007-01-01

    Computerized adaptive testing (CAT) has unsurpassable advantages over traditional testing. It has become the mainstream in large scale examinations in modern society. This paper gives a brief introduction to CAT including differences between traditional testing and CAT, the principles of CAT, psychometric theory and computer algorithms of CAT, the…

  19. Computerized Adaptive Testing: An Overview and an Example.

    ERIC Educational Resources Information Center

    McBride, James R.

    The advantages of computerized adaptive testing are discussed, and an example illustrates its use in sixth grade mathematics. These tests are administered at a computer terminal, and the test items to be administered are selected according to the difficulty level appropriate to the individual's ability. Tailoring increases the psychometric…

  20. The Relationship Between Computer Experience and Computerized Cognitive Test Performance Among Older Adults

    PubMed Central

    2013-01-01

    Objective. This study compared the relationship between computer experience and performance on computerized cognitive tests and a traditional paper-and-pencil cognitive test in a sample of older adults (N = 634). Method. Participants completed computer experience and computer attitudes questionnaires, three computerized cognitive tests (Useful Field of View (UFOV) Test, Road Sign Test, and Stroop task) and a paper-and-pencil cognitive measure (Trail Making Test). Multivariate analysis of covariance was used to examine differences in cognitive performance across the four measures between those with and without computer experience after adjusting for confounding variables. Results. Although computer experience had a significant main effect across all cognitive measures, the effect sizes were similar. After controlling for computer attitudes, the relationship between computer experience and UFOV was fully attenuated. Discussion. Findings suggest that computer experience is not uniquely related to performance on computerized cognitive measures compared with paper-and-pencil measures. Because the relationship between computer experience and UFOV was fully attenuated by computer attitudes, this may imply that motivational factors are more influential to UFOV performance than computer experience. Our findings support the hypothesis that computer use is related to cognitive performance, and this relationship is not stronger for computerized cognitive measures. Implications and directions for future research are provided. PMID:22929395

  1. Computerized Adaptive Testing: Overview and Introduction.

    ERIC Educational Resources Information Center

    Meijer, Rob R.; Nering, Michael L.

    1999-01-01

    Provides an overview of computerized adaptive testing (CAT) and introduces contributions to this special issue. CAT elements discussed include item selection, estimation of the latent trait, item exposure, measurement precision, and item-bank development. (SLD)

  2. Procedures for Selecting Items for Computerized Adaptive Tests.

    ERIC Educational Resources Information Center

    Kingsbury, G. Gage; Zara, Anthony R.

    1989-01-01

    Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)

  3. Hubble Space Telescope nickel-hydrogen battery testing: An update

    NASA Technical Reports Server (NTRS)

    Whitt, Thomas H.; Brewer, Jeffrey C.

    1995-01-01

    The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

  4. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    PubMed

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Development and Simulation Testing of a Computerized Adaptive Version of the Philadelphia Naming Test

    ERIC Educational Resources Information Center

    Hula, William D.; Kellough, Stacey; Fergadiotis, Gerasimos

    2015-01-01

    Purpose: The purpose of this study was to develop a computerized adaptive test (CAT) version of the Philadelphia Naming Test (PNT; Roach, Schwartz, Martin, Grewal, & Brecher, 1996), to reduce test length while maximizing measurement precision. This article is a direct extension of a companion article (Fergadiotis, Kellough, & Hula, 2015),…

  6. Computerized Adaptive Testing, Anxiety Levels, and Gender Differences

    ERIC Educational Resources Information Center

    Fritts, Barbara E.; Marszalek, Jacob M.

    2010-01-01

    This study compares the amount of test anxiety experienced on a computerized adaptive test (CAT) to a paper-and-pencil test (P&P), as well as the state test anxiety experienced between males and females. Ninety-four middle school CAT examinees were compared to 65 middle school P&P examinees on their responses to the State-Trait Anxiety…

  7. Effects of a Computerized Program on Use of the Test-Taking Strategy by Secondary Students with Disabilities

    ERIC Educational Resources Information Center

    Lancaster, Paula E.; Schumaker, Jean B.; Lancaster, Sean J. C.; Deshler, Donald D.

    2009-01-01

    Students with disabilities must meet many testing demands, given the current emphasis on accountability and state competency testing. The purpose of this project was to develop and field test a computerized program to teach the Test-Taking Strategy (Hughes, Schumaker, Deshler, & Mercer, 1988) to secondary-level students with disabilities. The…

  8. A Multiple Objective Test Assembly Approach for Exposure Control Problems in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Veldkamp, Bernard P.; Verschoor, Angela J.; Eggen, Theo J. H. M.

    2010-01-01

    Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT) systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has…

  9. An Efficiency Balanced Information Criterion for Item Selection in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2012-01-01

    Successful administration of computerized adaptive testing (CAT) programs in educational settings requires that test security and item exposure control issues be taken seriously. Developing an item selection algorithm that strikes the right balance between test precision and level of item pool utilization is the key to successful implementation…

  10. Variable-Length Computerized Adaptive Testing: Adaptation of the A-Stratified Strategy in Item Selection with Content Balancing

    ERIC Educational Resources Information Center

    Huo, Yan

    2009-01-01

    Variable-length computerized adaptive testing (CAT) can provide examinees with tailored test lengths. With the fixed standard error of measurement ("SEM") termination rule, variable-length CAT can achieve predetermined measurement precision by using relatively shorter tests compared to fixed-length CAT. To explore the application of…

  11. A "Rearrangement Procedure" for Scoring Adaptive Tests with Review Options.

    ERIC Educational Resources Information Center

    Papanastasiou, Elena C.

    Due to the increased popularity of computerized adaptive testing (CAT), many admissions tests, as well as certification and licensure examinations, have been transformed from their paper-and-pencil versions to computerized adaptive versions. A major difference between paper-and-pencil tests and CAT, from an examinees point of view, is that in many…

  12. A "Rearrangement Procedure" for Scoring Adaptive Tests with Review Options

    ERIC Educational Resources Information Center

    Papanastasiou, Elena C.; Reckase, Mark D.

    2007-01-01

    Because of the increased popularity of computerized adaptive testing (CAT), many admissions tests, as well as certification and licensure examinations, have been transformed from their paper-and-pencil versions to computerized adaptive versions. A major difference between paper-and-pencil tests and CAT from an examinee's point of view is that in…

  13. A Comparison of Procedures for Content-Sensitive Item Selection in Computerized Adaptive Tests.

    ERIC Educational Resources Information Center

    Kingsbury, G. Gage; Zara, Anthony R.

    1991-01-01

    This simulation investigated two procedures that reduce differences between paper-and-pencil testing and computerized adaptive testing (CAT) by making CAT content sensitive. Results indicate that the price in terms of additional test items of using constrained CAT for content balancing is much smaller than that of using testlets. (SLD)

  14. Controlling Item Exposure Conditional on Ability in Computerized Adaptive Testing.

    ERIC Educational Resources Information Center

    Stocking, Martha L.; Lewis, Charles

    1998-01-01

    Ensuring item and pool security in a continuous testing environment is explored through a new method of controlling exposure rate of items conditional on ability level in computerized testing. Properties of this conditional control on exposure rate, when used in conjunction with a particular adaptive testing algorithm, are explored using simulated…

  15. Cross-Validation of the Computerized Adaptive Screening Test (CAST).

    ERIC Educational Resources Information Center

    Pliske, Rebecca M.; And Others

    The Computerized Adaptive Screening Test (CAST) was developed to provide an estimate at recruiting stations of prospects' Armed Forces Qualification Test (AFQT) scores. The CAST was designed to replace the paper-and-pencil Enlistment Screening Test (EST). The initial validation study of CAST indicated that CAST predicts AFQT at least as accurately…

  16. Designing and evaluating Brain Powered Games for cognitive training and rehabilitation in at-risk African children.

    PubMed

    Giordani, B; Novak, B; Sikorskii, A; Bangirana, P; Nakasujja, N; Winn, B M; Boivin, M J

    2015-01-01

    Valid, reliable, accessible, and cost-effective computer-training approaches can be important components in scaling up educational support across resource-poor settings, such as sub-Saharan Africa. The goal of the current study was to develop a computer-based training platform, the Michigan State University Games for Entertainment and Learning laboratory's Brain Powered Games (BPG) package that would be suitable for use with at-risk children within a rural Ugandan context and then complete an initial field trial of that package. After game development was completed with the use of local stimuli and sounds to match the context of the games as closely as possible to the rural Ugandan setting, an initial field study was completed with 33 children (mean age = 8.55 ± 2.29 years, range 6-12 years of age) with HIV in rural Uganda. The Test of Variables of Attention (TOVA), CogState computer battery, and the Non-Verbal Index from the Kaufman Assessment Battery for Children, 2nd edition (KABC-II) were chosen as the outcome measures for pre- and post-intervention testing. The children received approximately 45 min of BPG training several days per week for 2 months (24 sessions). Although some improvements in test scores were evident prior to BPG training, following training, children demonstrated clinically significant changes (significant repeated-measures outcomes with moderate to large effect sizes) on specific TOVA and CogState measures reflecting processing speed, attention, visual-motor coordination, maze learning, and problem solving. Results provide preliminary support for the acceptability, feasibility, and neurocognitive benefit of BPG and its utility as a model platform for computerized cognitive training in cross-cultural low-resource settings.

  17. Frontal D2/3 Receptor Availability in Schizophrenia Patients Before and After Their First Antipsychotic Treatment: Relation to Cognitive Functions and Psychopathology.

    PubMed

    Nørbak-Emig, Henrik; Ebdrup, Bjørn H; Fagerlund, Birgitte; Svarer, Claus; Rasmussen, Hans; Friberg, Lars; Allerup, Peter N; Rostrup, Egill; Pinborg, Lars H; Glenthøj, Birte Y

    2016-05-01

    We have previously reported associations between frontal D2/3 receptor binding potential positive symptoms and cognitive deficits in antipsychotic-naïve schizophrenia patients. Here, we examined the effect of dopamine D2/3 receptor blockade on cognition. Additionally, we explored the relation between frontal D2/3 receptor availability and treatment effect on positive symptoms. Twenty-five antipsychotic-naïve first-episode schizophrenia patients were examined with the Positive and Negative Syndrome Scale, tested with the cognitive test battery Cambridge Neuropsychological Test Automated Battery, scanned with single-photon emission computerized tomography using the dopamine D2/3 receptor ligand [(123)I]epidepride, and scanned with MRI. After 3 months of treatment with either risperidone (n=13) or zuclopenthixol (n=9), 22 patients were reexamined. Blockade of extrastriatal dopamine D2/3 receptors was correlated with decreased attentional focus (r = -0.615, P=.003) and planning time (r = -0.436, P=.048). Moreover, baseline frontal dopamine D2/3 binding potential and positive symptom reduction correlated positively (D2/3 receptor binding potential left frontal cortex rho = 0.56, P=.003; D2/3 receptor binding potential right frontal cortex rho = 0.48, P=.016). Our data support the hypothesis of a negative influence of D2/3 receptor blockade on specific cognitive functions in schizophrenia. This is highly clinically relevant given the well-established association between severity of cognitive disturbances and a poor functional outcome in schizophrenia. Additionally, the findings support associations between frontal D2/3 receptor binding potential at baseline and the effect of antipsychotic treatment on positive symptoms. © The Author 2016. Published by Oxford University Press on behalf of CINP.

  18. Computerization of material test data reporting system : interim report.

    DOT National Transportation Integrated Search

    1973-09-01

    This study was initiated to provide an integrated system of reporting, storing, and retrieving of construction and material test data using computerized (storage-retrieval) and quality control techniques. The findings reported in this interim report ...

  19. Computerized NCLEX-RN and NCLEX-PN preparation programs. Comparative review, 1997.

    PubMed

    Riner, M E; Mueller, C; Ihrke, B; Smolen, R A; Wilson, M; Richardson, V; Stone, C; Zwirn, E E

    1997-01-01

    The computerized test taking market continues to expand to meet the needs of nursing students studying to prepare for the NCLEX-RN and the NCLEX-PN. In addition, currently registered nurses may choose to use these software programs to review clinical knowledge in areas in which they are not currently practicing. This article reviewed software designed for personal use, review books with complete disks, on-site institutional testing and consultation, and school of nursing LANs. The costs of software for personal use is priced reasonably and provides flexibility for students to use as their schedule permits. The cost of institutional licenses is moderate and most programs provide multiple on-site use rights. The marketplace has responded to the computerized NCLEX testing now in place nationally. As new formats are developed and new uses identified, nursing faculty and students can expect to see an expanded use of computerized testing.

  20. HIL Development and Validation of Lithium-ion Battery Packs (SAE 2014-01-1863)

    EPA Science Inventory

    A Battery Test Facility (BTF) has been constructed at United States Environmental Protection Agency (EPA) to test various automotive battery packs for HEV, PHEV, and EV vehicles. Battery pack tests were performed in the BTF using a battery cycler, testing controllers, battery pa...

  1. Individual Differences in Computerized Adaptive Testing.

    ERIC Educational Resources Information Center

    Kim, JinGyu

    Research on the major computerized adaptive testing (CAT) strategies is reviewed, and some findings are reported that examine effects of examinee demographic and psychological characteristics on CAT strategies. In fixed branching strategies, all examinees respond to a common routing test, the score of which is used to assign examinees to a…

  2. Multidimensional Computerized Adaptive Testing for Indonesia Junior High School Biology

    ERIC Educational Resources Information Center

    Kuo, Bor-Chen; Daud, Muslem; Yang, Chih-Wei

    2015-01-01

    This paper describes a curriculum-based multidimensional computerized adaptive test that was developed for Indonesia junior high school Biology. In adherence to the Indonesian curriculum of different Biology dimensions, 300 items was constructed, and then tested to 2238 students. A multidimensional random coefficients multinomial logit model was…

  3. Using Unidimensional IRT Models for Dichotomous Classification via Computerized Classification Testing with Multidimensional Data.

    ERIC Educational Resources Information Center

    Lau, Che-Ming Allen; And Others

    This study focused on the robustness of unidimensional item response theory (UIRT) models in computerized classification testing against violation of the unidimensionality assumption. The study addressed whether UIRT models remain acceptable under various testing conditions and dimensionality strengths. Monte Carlo simulation techniques were used…

  4. Computerized Numerical Control Test Item Bank.

    ERIC Educational Resources Information Center

    Reneau, Fred; And Others

    This guide contains 285 test items for use in teaching a course in computerized numerical control. All test items were reviewed, revised, and validated by incumbent workers and subject matter instructors. Items are provided for assessing student achievement in such aspects of programming and planning, setting up, and operating machines with…

  5. On the Issue of Item Selection in Computerized Adaptive Testing with Response Times

    ERIC Educational Resources Information Center

    Veldkamp, Bernard P.

    2016-01-01

    Many standardized tests are now administered via computer rather than paper-and-pencil format. The computer-based delivery mode brings with it certain advantages. One advantage is the ability to adapt the difficulty level of the test to the ability level of the test taker in what has been termed computerized adaptive testing (CAT). A second…

  6. Multidimensional Computerized Adaptive Scholastic Aptitude Test Program Used for Grade 9 Students under Different Reviewing Test Conditions

    ERIC Educational Resources Information Center

    Khunkrai, Naruemon; Sawangboon, Tatsirin; Ketchatturat, Jatuphum

    2015-01-01

    The aim of this research is to study the accurate prediction of comparing test information and evaluation result by multidimensional computerized adaptive scholastic aptitude test program used for grade 9 students under different reviewing test conditions. Grade 9 students of the Secondary Educational Service Area Office in the North-east of…

  7. Angina pectoris severity among coronary heart disease patients is associated with subsequent cognitive impairment.

    PubMed

    Weinstein, Galit; Goldbourt, Uri; Tanne, David

    2015-01-01

    The relationship between coronary heart disease (CHD) and cognitive function is not completely elucidated. We examined the association between severity of angina pectoris (AP) in mid-life and subsequent cognitive impairment among CHD patients. Severity of AP according to the Canadian Cardiovascular Society angina classification was assessed in a subgroup of people with chronic CHD, who previously participated in a secondary prevention trial. Cognitive performance was evaluated 15±3 years later, using a validated set of computerized cognitive tests (Neurotrax Computerized Cognitive Battery; computing index scores summarizing performance in each cognitive domain and a global cognitive score). We compared the risk of cognitive deficits in participants with AP class >2 to those with AP≤2, adjusting for vascular risk factors, common carotid-intima media thickness (CC-IMT), and presence of carotid plaques. Among 535 participants (mean age at baseline 57.9±6.6 y; 95% males), AP class >2 was associated with subsequent poorer performance on tests of memory and attention compared to those with AP class ≤2 (β=-4.3±1.8; P=0.016 and β=-3.6±1.7; P=0.029, respectively) and with a higher risk of having impairment in these domains [odds ratio (95% confidence interval)=1.83 (1.11-3.02); P=0.019 and 2.36 (1.34-4.16); P=0.003, for memory and attention, respectively]. These results were similar after controlling for vascular risk factors; however, the association of AP with memory domain attenuated after adjustment for CC-IMT or presence of carotid plaques. In people with preexisting CHD, severity of AP is associated with late-life poorer cognitive performance, independent of other vascular risk factors.

  8. Validation of a Computerized test of Functional Capacity.

    PubMed

    Keefe, Richard S E; Davis, Vicki G; Atkins, Alexandra S; Vaughan, Adam; Patterson, Tom; Narasimhan, Meera; Harvey, Philip D

    2016-08-01

    Regulatory guidance for schizophrenia cognition clinical trials requires that the assessment of cognitive change is accompanied by a functionally meaningful endpoint. However, currently available measures are challenged by resistance to change, psychometric weaknesses, and for interview-based assessments, dependence upon the presence of an informant. The aims of the current study were to: 1) assess the validity, sensitivity, and reliability of the Virtual Reality Functional Capacity Assessment Tool (VRFCAT) as a measure of functional capacity; 2) determine the association between performance on the VRFCAT and performance on the MATRICS Consensus Cognitive Battery (MCCB); and 3) compare the metrics of the VRFCAT with the UCSD Performance-based Skills Assessment (UPSA). 167 patients with schizophrenia and 166 healthy controls completed the VRFCAT, UPSA, and the MCCB at baseline. The VRFCAT and UPSA were completed again at follow-up. The VRFCAT, MCCB, and UPSA were very sensitive to impairment in schizophrenia (d=1.16 to 1.22). High test-retest reliability was demonstrated for VRFCAT total completion time and the UPSA total score in patients (ICC=0.81 and 0.78, respectively). The UPSA demonstrated significant practice effects in patients (d=0.35), while the VRFCAT did not (d=-0.04). VRFCAT total completion time was correlated with both UPSA (r=-0.56, p<0.0001 for patients and -0.58, p<0.0001 for controls) and MCCB Composite (r=-0.57, p<0.0001 for patients and -0.68, p<0.0001 for controls). The VRFCAT is a highly reliable and sensitive measure of functional capacity with associations to the UPSA and MCCB. These results provide encouraging support for a computerized functional capacity assessment for use in schizophrenia. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Validation of a Computerized Test of Functional Capacity

    PubMed Central

    Keefe, Richard S.E.; Davis, Vicki G.; Atkins, Alexandra S.; Vaughan, Adam; Patterson, Tom; Narasimhan, Meera; Harvey, Philip D.

    2016-01-01

    Regulatory guidance for schizophrenia cognition clinical trials requires that the assessment of cognitive change is accompanied by a functionally meaningful endpoint. However, currently available measures are challenged by resistance to change, psychometric weaknesses, and for interview-based assessments, dependence upon the presence of an informant. The aims of the current study were to: 1) assess the validity, sensitivity, and reliability of the Virtual Reality Functional Capacity Assessment Tool (VRFCAT) as a measure of functional capacity; 2) determine the association between performance on the VRFCAT and performance on the MATRICS Consensus Cognitive Battery (MCCB); and 3) compare the metrics of the VRFCAT with the UCSD Performance-based Skills Assessment (UPSA). 167 patients with schizophrenia and 166 healthy controls completed the VRFCAT, UPSA, and the MCCB at baseline. The VRFCAT and UPSA were completed again at follow-up. The VRFCAT, MCCB, and UPSA were very sensitive to impairment in schizophrenia (d = 1.16 to 1.22). High test-retest reliability was demonstrated for VRFCAT total completion time and the UPSA total score in patients (ICC=0.81 and 0.78, respectively). The UPSA demonstrated significant practice effects in patients (d=0.35), while the VRFCAT did not (d=−0.04). VRFCAT total completion time was correlated with both UPSA (r=−0.56, p<0.0001 for patients and −0.58, p<0.0001 for controls) and MCCB Composite (r=−0.57, p<0.0001 for patients and −0.68, p<0.0001 for controls). The VRFCAT is a highly reliable and sensitive measure of functional capacity with associations to the UPSA and MCCB. These results provide encouraging support for a computerized functional capacity assessment for use in schizophrenia. PMID:27091656

  10. Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis

    NASA Technical Reports Server (NTRS)

    Marley, Mike

    2008-01-01

    The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.

  11. Documentation of CTRS--Computerized Test-Result Reporting System. The Illinois Series on Educational Application of Computers, No. 22e.

    ERIC Educational Resources Information Center

    Muiznieks, Viktors J.; Cox, John

    The Computerized Test-Result Reporting System (CTRS), which consists of three programs written in the BASIC language, was developed to analyze obective tests, test items, test results, and to provide the teacher-user with interpreted data about the performance of tests, Lest items, and students. This paper documents the three programs from the…

  12. The Influence of Item Calibration Error on Variable-Length Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Patton, Jeffrey M.; Cheng, Ying; Yuan, Ke-Hai; Diao, Qi

    2013-01-01

    Variable-length computerized adaptive testing (VL-CAT) allows both items and test length to be "tailored" to examinees, thereby achieving the measurement goal (e.g., scoring precision or classification) with as few items as possible. Several popular test termination rules depend on the standard error of the ability estimate, which in turn depends…

  13. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    ERIC Educational Resources Information Center

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  14. Assembling a Computerized Adaptive Testing Item Pool as a Set of Linear Tests

    ERIC Educational Resources Information Center

    van der Linden, Wim J.; Ariel, Adelaide; Veldkamp, Bernard P.

    2006-01-01

    Test-item writing efforts typically results in item pools with an undesirable correlational structure between the content attributes of the items and their statistical information. If such pools are used in computerized adaptive testing (CAT), the algorithm may be forced to select items with less than optimal information, that violate the content…

  15. Revisiting a Cognitive Framework for Test Design: Applications for a Computerized Perceptual Speed Test.

    ERIC Educational Resources Information Center

    Alderton, David L.

    This paper highlights the need for a systematic, content aware, and theoretically-based approach to test design. The cognitive components approach is endorsed, and is applied to the development of a computerized perceptual speed test. Psychometric literature is reviewed and shows that: every major multi-factor theory includes a clerical/perceptual…

  16. Skilled but Unaware of It: CAT Undermines a Test Taker's Metacognitive Competence

    ERIC Educational Resources Information Center

    Ortner, Tuulia M.; Weisskopf, Eva; Gerstenberg, Friederike X. R.

    2013-01-01

    We investigated students' metacognitive experiences with regard to feelings of difficulty (FD), feelings of satisfaction (FS), and estimate of effort (EE), employing either computerized adaptive testing (CAT) or computerized fixed item testing (FIT). In an experimental approach, 174 students in grades 10 to 13 were tested either with a CAT or a…

  17. Can Computerized Adaptive Testing Work in Students' Admission to Higher Education Programs in Turkey?

    ERIC Educational Resources Information Center

    Kalender, Ilker; Berberoglu, Giray

    2017-01-01

    Admission into university in Turkey is very competitive and features a number of practical problems regarding not only the test administration process itself, but also concerning the psychometric properties of test scores. Computerized adaptive testing (CAT) is seen as a possible alternative approach to solve these problems. In the first phase of…

  18. A Fair Comparison of the Performance of Computerized Adaptive Testing and Multistage Adaptive Testing

    ERIC Educational Resources Information Center

    Wang, Keyin

    2017-01-01

    The comparison of item-level computerized adaptive testing (CAT) and multistage adaptive testing (MST) has been researched extensively (e.g., Kim & Plake, 1993; Luecht et al., 1996; Patsula, 1999; Jodoin, 2003; Hambleton & Xing, 2006; Keng, 2008; Zheng, 2012). Various CAT and MST designs have been investigated and compared under the same…

  19. A computerized clinical decision support system as a means of implementing depression guidelines.

    PubMed

    Trivedi, Madhukar H; Kern, Janet K; Grannemann, Bruce D; Altshuler, Kenneth Z; Sunderajan, Prabha

    2004-08-01

    The authors describe the history and current use of computerized systems for implementing treatment guidelines in general medicine as well as the development, testing, and early use of a computerized decision support system for depression treatment among "real-world" clinical settings in Texas. In 1999 health care experts from Europe and the United States met to confront the well-documented challenges of implementing treatment guidelines and to identify strategies for improvement. They suggested the integration of guidelines into computer systems that is incorporated into clinical workflow. Several studies have demonstrated improvements in physicians' adherence to guidelines when such guidelines are provided in a computerized format. Although computerized decision support systems are being used in many areas of medicine and have demonstrated improved patient outcomes, their use in psychiatric illness is limited. The authors designed and developed a computerized decision support system for the treatment of major depressive disorder by using evidence-based guidelines, transferring the knowledge gained from the Texas Medication Algorithm Project (TMAP). This computerized decision support system (CompTMAP) provides support in diagnosis, treatment, follow-up, and preventive care and can be incorporated into the clinical setting. CompTMAP has gone through extensive testing to ensure accuracy and reliability. Physician surveys have indicated a positive response to CompTMAP, although the sample was insufficient for statistical testing. CompTMAP is part of a new era of comprehensive computerized decision support systems that take advantage of advances in automation and provide more complete clinical support to physicians in clinical practice.

  20. Individualized identification of euthymic bipolar disorder using the Cambridge Neuropsychological Test Automated Battery (CANTAB) and machine learning.

    PubMed

    Wu, Mon-Ju; Passos, Ives Cavalcante; Bauer, Isabelle E; Lavagnino, Luca; Cao, Bo; Zunta-Soares, Giovana B; Kapczinski, Flávio; Mwangi, Benson; Soares, Jair C

    2016-03-01

    Previous studies have reported that patients with bipolar disorder (BD) present with cognitive impairments during mood episodes as well as euthymic phase. However, it is still unknown whether reported neurocognitive abnormalities can objectively identify individual BD patients from healthy controls (HC). A total of 21 euthymic BD patients and 21 demographically matched HC were included in the current study. Participants performed the computerized Cambridge Neurocognitive Test Automated Battery (CANTAB) to assess cognitive performance. The least absolute shrinkage selection operator (LASSO) machine learning algorithm was implemented to identify neurocognitive signatures to distinguish individual BD patients from HC. The LASSO machine learning algorithm identified individual BD patients from HC with an accuracy of 71%, area under receiver operating characteristic curve of 0.7143 and significant at p=0.0053. The LASSO algorithm assigned individual subjects with a probability score (0-healthy, 1-patient). Patients with rapid cycling (RC) were assigned increased probability scores as compared to patients without RC. A multivariate pattern of neurocognitive abnormalities comprising of affective Go/No-go and the Cambridge gambling task was relevant in distinguishing individual patients from HC. Our study sample was small as we only considered euthymic BD patients and demographically matched HC. Neurocognitive abnormalities can distinguish individual euthymic BD patients from HC with relatively high accuracy. In addition, patients with RC had more cognitive impairments compared to patients without RC. The predictive neurocognitive signature identified in the current study can potentially be used to provide individualized clinical inferences on BD patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Marshall Space Flight Center battery activity

    NASA Technical Reports Server (NTRS)

    Lowery, Eric

    1993-01-01

    The topics covered are presented in viewgraph form and include a flight program history and in-house activities. Some of the in-house activities addressed include secondary battery/cell testing and Hubble Space Telescope Test data updates involving the NiCd type 40 test - battery 1 and 2, the NiCd type 41 test battery, the general electric battery, the NiCd six-battery system, the six four-cell packs, fourteen-cell pack, three four-cell packs, the NiH2 six-battery system, and the flight spare battery. A general test data update is also presented for the twelve-cell pack, the four four-cell packs, the reconditioning test, and planned Ni-MH testing.

  2. Use of COTS Batteries on ISS and Shuttle

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.

    2004-01-01

    This presentation focuses on COTS Battery testing for energy content, toxicity, hazards, failures modes and controls for different battery chemistries. It also discusses the current program requirements, challenges with COTS Batteries in manned vehicle COTS methodology, JSC test details, and gives a list of incidents from consumer protection safety commissions. The Battery test process involved testing new batteries for engineering certification, qualification of batteries, flight acceptance, cell and battery, environment, performance and abuse. Their conclusions and recommendations were that: high risk is undertaken with the use of COTS batteries, hazard control verification is required to allow the use of these batteries on manned space flights, failures during use cannot be understood if different scenarios of failure are not tested on the ground, and that testing is performed on small sample numbers due to restrictions on cost and time. They recommend testing of large sample size to gain more confidence in the operation of the hazard controls.

  3. A case matched study examining the reliability of using ImPACT to assess effects of multiple concussions.

    PubMed

    Barker, Trevor; Russo, Stephen A; Barker, Gaytri; Rice, Mark A; Jeffrey, Mary G; Broderick, Gordon; Craddock, Travis J A

    2017-04-28

    Approximately 3.8 million sport and recreational concussions occur per year, creating a need for accurate diagnosis and management of concussions. Researchers and clinicians are exploring the potential dose-response cumulative effects of concussive injuries using computerized neuropsychological exams, however, results have been mixed and/or contradictory. This study starts with a large adolescent population and applies strict inclusion criteria to examine how previous mild traumatic brain injuries affect symptom reports and neurocognitive performance on the Immediate Post-concussion Assessment and Cognitive Testing (ImPACT) computerized tool. After applying exclusion criteria and case matching, 204 male and 99 female participants remained. These participants were grouped according to sex and the number of previous self-reported concussions and examined for overall differences on symptoms reported and scores obtained on the ImPACT neurocognitive battery composites. In an effort to further reduce confounding factors due to the varying group sizes, participants were then case matched on age, sex, and body mass index and analyzed for differences on symptoms reported and scores obtained on the ImPACT neurocognitive battery composites. Case matched analysis demonstrated males with concussions experience significantly higher rates of dizziness (p = .027, η 2  = .035), fogginess (p = .038, η 2  = .032), memory problems (p = .003, η 2  = .055), and concentration problems (p = .009, η 2  = .046) than males with no reported previous concussions. No significant effects were found for females, although females reporting two concussions demonstrated a slight trend for experiencing higher numbers of symptoms than females reporting no previous concussions. The results suggest that male adolescent athletes reporting multiple concussions have lingering concussive symptoms well after the last concussive event; however, these symptoms were found to be conflicting and better explained by complainer versus complacent attitudes in the population examined. Our results conflict with a significant portion of the current literature that uses relatively lenient inclusion and exclusion criteria, providing evidence of the importance of strict inclusion and exclusion criteria and examination of confounding factors when assessing the effects of concussions.

  4. Upgraded demonstration vehicle task report

    NASA Technical Reports Server (NTRS)

    Bryant, J.; Hardy, K.; Livingston, R.; Sandberg, J.

    1981-01-01

    Vehicle/battery performance capabilities and interface problems that occurred when upgraded developmental batteries were integrated with upgraded versions of comercially available electric vehicles were investigated. Developmental batteries used included nickel zinc batteries, a nickel iron battery, and an improved lead acid battery. Testing of the electric vehicles and upgraded batteries was performed in the complete vehicle system environment to characterize performance and identify problems unique to the vehicle/battery system. Constant speed tests and driving schedule range tests were performed on a chassis dynamometer. The results from these tests of the upgraded batteries and vehicles were compared to performance capabilities for the same vehicles equipped with standard batteries.

  5. Deriving Stopping Rules for Multidimensional Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wang, Chun; Chang, Hua-Hua; Boughton, Keith A.

    2013-01-01

    Multidimensional computerized adaptive testing (MCAT) is able to provide a vector of ability estimates for each examinee, which could be used to provide a more informative profile of an examinee's performance. The current literature on MCAT focuses on the fixed-length tests, which can generate less accurate results for those examinees whose…

  6. A Mixture Rasch Model-Based Computerized Adaptive Test for Latent Class Identification

    ERIC Educational Resources Information Center

    Jiao, Hong; Macready, George; Liu, Junhui; Cho, Youngmi

    2012-01-01

    This study explored a computerized adaptive test delivery algorithm for latent class identification based on the mixture Rasch model. Four item selection methods based on the Kullback-Leibler (KL) information were proposed and compared with the reversed and the adaptive KL information under simulated testing conditions. When item separation was…

  7. Detection of Person Misfit in Computerized Adaptive Tests with Polytomous Items.

    ERIC Educational Resources Information Center

    van Krimpen-Stoop, Edith M. L. A.; Meijer, Rob R.

    2002-01-01

    Compared the nominal and empirical null distributions of the standardized log-likelihood statistic for polytomous items for paper-and-pencil (P&P) and computerized adaptive tests (CATs). Results show that the empirical distribution of the statistic differed from the assumed standard normal distribution for both P&P tests and CATs. Also…

  8. Optimal Stratification of Item Pools in a-Stratified Computerized Adaptive Testing.

    ERIC Educational Resources Information Center

    Chang, Hua-Hua; van der Linden, Wim J.

    2003-01-01

    Developed a method based on 0-1 linear programming to stratify an item pool optimally for use in alpha-stratified adaptive testing. Applied the method to a previous item pool from the computerized adaptive test of the Graduate Record Examinations. Results show the new method performs well in practical situations. (SLD)

  9. Computerized Adaptive Testing for Effective and Efficient Measurement in Counseling and Education

    ERIC Educational Resources Information Center

    Weiss, David J.

    2004-01-01

    Computerized adaptive testing (CAT) is described and compared with conventional tests, and its advantages summarized. Some item response theory concepts used in CAT are summarized and illustrated. The author describes the potential usefulness of CAT in counseling and education and reviews some current issues in the implementation of CAT.

  10. Preliminary Report on a National Cross-Validation of the Computerized Adaptive Screening Test (CAST).

    ERIC Educational Resources Information Center

    Knapp, Deirdre J.; Pliske, Rebecca M.

    A study was conducted to validate the Army's Computerized Adaptive Screening Test (CAST), using data from 2,240 applicants from 60 army recruiting stations across the nation. CAST is a computer-assisted adaptive test used to predict performance on the Armed Forces Qualification Test (AFQT). AFQT scores are computed by adding four subtest scores of…

  11. Person Fit Analysis in Computerized Adaptive Testing Using Tests for a Change Point

    ERIC Educational Resources Information Center

    Sinharay, Sandip

    2016-01-01

    Meijer and van Krimpen-Stoop noted that the number of person-fit statistics (PFSs) that have been designed for computerized adaptive tests (CATs) is relatively modest. This article partially addresses that concern by suggesting three new PFSs for CATs. The statistics are based on tests for a change point and can be used to detect an abrupt change…

  12. Gas Analyzer

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A miniature gas chromatograph, a system which separates a gaseous mixture into its components and measures the concentration of the individual gases, was designed for the Viking Lander. The technology was further developed under National Institute for Occupational Safety and Health (NIOSH) and funded by Ames Research Center/Stanford as a toxic gas leak detection device. Three researchers on the project later formed Microsensor Technology, Inc. to commercialize the product. It is a battery-powered system consisting of a sensing wand connected to a computerized analyzer. Marketed as the Michromonitor 500, it has a wide range of applications.

  13. Computerized lateral-shear interferometer

    NASA Astrophysics Data System (ADS)

    Hasegan, Sorin A.; Jianu, Angela; Vlad, Valentin I.

    1998-07-01

    A lateral-shear interferometer, coupled with a computer for laser wavefront analysis, is described. A CCD camera is used to transfer the fringe images through a frame-grabber into a PC. 3D phase maps are obtained by fringe pattern processing using a new algorithm for direct spatial reconstruction of the optical phase. The program describes phase maps by Zernike polynomials yielding an analytical description of the wavefront aberration. A compact lateral-shear interferometer has been built using a laser diode as light source, a CCD camera and a rechargeable battery supply, which allows measurements in-situ, if necessary.

  14. Role of tDCS in potentiating poststroke computerized cognitive rehabilitation: Lessons learned from a case study.

    PubMed

    Leo, Antonino; De Luca, Rosario; Russo, Margherita; Naro, Antonino; Bramanti, Placido; Calabrò, Rocco S

    2016-01-01

    Cognitive impairment after stroke is quite common and can cause important disability with a relevant impact on quality of life. Cognitive rehabilitation (CR) and related assistive technology may improve functional outcomes. A 30-year-old woman came to our research institute for an intensive CR cycle following a right parieto-temporal stroke. Because the patient was in the chronic phase, we decided to use 3 different rehabilitative protocols: (a) traditional cognitive training (TCT), (b) computerized cognitive training (CCT), and (c) CCT combined with transcranial direct stimulation (CCT plus) with a 2-week interval separating each session. Cognitive and language deficits were investigated using an ad-hoc psychometric battery at baseline (T0), post-TCT (T1), post-CCT (T2), and post-CCT plus (T3). Our patient showed the best neuropsychological improvement, with regard to attention processes and language domain, after T3. Our data showed that CCT plus should be considered a promising tool in the treatment of poststroke neuropsychological deficits.

  15. Ground Handling of Batteries at Test and Launch-site Facilities

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Hohl, Alan R.

    2008-01-01

    Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.

  16. Design Evaluation of High Reliability Lithium Batteries

    NASA Technical Reports Server (NTRS)

    Buchman, R. C.; Helgeson, W. D.; Istephanous, N. S.

    1985-01-01

    Within one year, a lithium battery design can be qualified for device use through the application of accelerated discharge testing, calorimetry measurements, real time tests and other supplemental testing. Materials and corrosion testing verify that the battery components remain functional during expected battery life. By combining these various methods, a high reliability lithium battery can be manufactured for applications which require zero defect battery performance.

  17. The effects of mild and severe traumatic brain injury on speed of information processing as measured by the computerized tests of information processing (CTIP).

    PubMed

    Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra

    2007-01-01

    In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.

  18. Computerized test versus personal interview as admission methods for graduate nursing studies: A retrospective cohort study.

    PubMed

    Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana

    2016-12-01

    The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.

  19. NASA/Marshall's lithium battery applications

    NASA Technical Reports Server (NTRS)

    Paschal, L. E.

    1980-01-01

    A general lithium battery is described and a summary of lithium battery applications is presented. Four aspects of a particular lithium battery, the inducement environmental contamination monitoring battery, are discussed-design and construction details, thermal vacuum tests, projection tests, and acceptance tests.

  20. A Bayesian Method for the Detection of Item Preknowledge in CAT. Law School Admission Council Computerized Testing Report. LSAC Research Report Series.

    ERIC Educational Resources Information Center

    McLeod, Lori D.; Lewis, Charles; Thissen, David.

    With the increased use of computerized adaptive testing, which allows for continuous testing, new concerns about test security have evolved, one being the assurance that items in an item pool are safeguarded from theft. In this paper, the risk of score inflation and procedures to detect test takers using item preknowledge are explored. When test…

  1. A Comparison of Validity Rates between Paper-and-Pencil and Computerized Testing with the MMPI-2

    ERIC Educational Resources Information Center

    Blazek, Nicole L.; Forbey, Johnathan D.

    2011-01-01

    Although the use of computerized testing in psychopathology assessment has increased in recent years, limited research has examined the impact of this format in terms of potential differences in test validity rates. The current study explores potential differences in the rates of valid and invalid Minnesota Multiphasic Personality Inventory--2…

  2. Mutual Information Item Selection Method in Cognitive Diagnostic Computerized Adaptive Testing with Short Test Length

    ERIC Educational Resources Information Center

    Wang, Chun

    2013-01-01

    Cognitive diagnostic computerized adaptive testing (CD-CAT) purports to combine the strengths of both CAT and cognitive diagnosis. Cognitive diagnosis models aim at classifying examinees into the correct mastery profile group so as to pinpoint the strengths and weakness of each examinee whereas CAT algorithms choose items to determine those…

  3. Assessment of Selective Attention with CSCWT (Computerized Stroop Color-Word Test) among Children and Adults

    ERIC Educational Resources Information Center

    Afsaneh, Zarghi; Alireza, Zali; Mehdi, Tehranidost; Farzad, Ashrafi; Reza, Zarindast Mohammad; Mehdi, Moazzezi; Mojtaba, Khodadadi Seyed

    2012-01-01

    The SCWT (Stroop Color-Word Test) is a quick and frequently used measure for assessing selective attention and cognitive flexibility. This study determines age, sex and education level influence on attention and cognitive flexibility by CSCWT (Computerized Stroop Color-Word Test) among healthy Iranian children and adults. There were 78 healthy…

  4. Comparing Assessments of Students' Knowledge by Computerized Open-Ended and Multiple-Choice Tests.

    ERIC Educational Resources Information Center

    Anbar, Michael

    1991-01-01

    Interactive computerized tests accepting unrestricted natural-language input were used to assess knowledge of clinical biophysics at the State University of New York at Buffalo. Comparison of responses to open-ended sequential questions and multiple-choice questions on the same material found the two formats test different aspects of competence.…

  5. Strategies for Controlling Item Exposure in Computerized Adaptive Testing with the Generalized Partial Credit Model

    ERIC Educational Resources Information Center

    Davis, Laurie Laughlin

    2004-01-01

    Choosing a strategy for controlling item exposure has become an integral part of test development for computerized adaptive testing (CAT). This study investigated the performance of six procedures for controlling item exposure in a series of simulated CATs under the generalized partial credit model. In addition to a no-exposure control baseline…

  6. Severity of Organized Item Theft in Computerized Adaptive Testing: An Empirical Study. Research Report. ETS RR-06-22

    ERIC Educational Resources Information Center

    Yi, Qing; Zhang, Jinming; Chang, Hua-Hua

    2006-01-01

    Chang and Zhang (2002, 2003) proposed several baseline criteria for assessing the severity of possible test security violations for computerized tests with high-stakes outcomes. However, these criteria were obtained from theoretical derivations that assumed uniformly randomized item selection. The current study investigated potential damage caused…

  7. Development and Application of Detection Indices for Measuring Guessing Behaviors and Test-Taking Effort in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Chang, Shu-Ren; Plake, Barbara S.; Kramer, Gene A.; Lien, Shu-Mei

    2011-01-01

    This study examined the amount of time that different ability-level examinees spend on questions they answer correctly or incorrectly across different pretest item blocks presented on a fixed-length, time-restricted computerized adaptive testing (CAT). Results indicate that different ability-level examinees require different amounts of time to…

  8. Application of Computerized Adaptive Testing to Entrance Examination for Graduate Studies in Turkey

    ERIC Educational Resources Information Center

    Bulut, Okan; Kan, Adnan

    2012-01-01

    Problem Statement: Computerized adaptive testing (CAT) is a sophisticated and efficient way of delivering examinations. In CAT, items for each examinee are selected from an item bank based on the examinee's responses to the items. In this way, the difficulty level of the test is adjusted based on the examinee's ability level. Instead of…

  9. The Application of the Monte Carlo Approach to Cognitive Diagnostic Computerized Adaptive Testing With Content Constraints

    ERIC Educational Resources Information Center

    Mao, Xiuzhen; Xin, Tao

    2013-01-01

    The Monte Carlo approach which has previously been implemented in traditional computerized adaptive testing (CAT) is applied here to cognitive diagnostic CAT to test the ability of this approach to address multiple content constraints. The performance of the Monte Carlo approach is compared with the performance of the modified maximum global…

  10. Comparing and Combining Dichotomous and Polytomous Items with SPRT Procedure in Computerized Classification Testing.

    ERIC Educational Resources Information Center

    Lau, C. Allen; Wang, Tianyou

    The purposes of this study were to: (1) extend the sequential probability ratio testing (SPRT) procedure to polytomous item response theory (IRT) models in computerized classification testing (CCT); (2) compare polytomous items with dichotomous items using the SPRT procedure for their accuracy and efficiency; (3) study a direct approach in…

  11. A New Item Selection Procedure for Mixed Item Type in Computerized Classification Testing.

    ERIC Educational Resources Information Center

    Lau, C. Allen; Wang, Tianyou

    This paper proposes a new Information-Time index as the basis for item selection in computerized classification testing (CCT) and investigates how this new item selection algorithm can help improve test efficiency for item pools with mixed item types. It also investigates how practical constraints such as item exposure rate control, test…

  12. When Cognitive Diagnosis Meets Computerized Adaptive Testing: CD-CAT

    ERIC Educational Resources Information Center

    Cheng, Ying

    2009-01-01

    Computerized adaptive testing (CAT) is a mode of testing which enables more efficient and accurate recovery of one or more latent traits. Traditionally, CAT is built upon Item Response Theory (IRT) models that assume unidimensionality. However, the problem of how to build CAT upon latent class models (LCM) has not been investigated until recently,…

  13. Optimizing the Use of Response Times for Item Selection in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Choe, Edison M.; Kern, Justin L.; Chang, Hua-Hua

    2018-01-01

    Despite common operationalization, measurement efficiency of computerized adaptive testing should not only be assessed in terms of the number of items administered but also the time it takes to complete the test. To this end, a recent study introduced a novel item selection criterion that maximizes Fisher information per unit of expected response…

  14. Validation of a Computerized Cognitive Assessment System for Persons with Stroke: A Pilot Study

    ERIC Educational Resources Information Center

    Yip, Chi Kwong; Man, David W. K.

    2009-01-01

    This study investigates the validity of a newly developed computerized cognitive assessment system (CCAS) that is equipped with rich multimedia to generate simulated testing situations and considers both test item difficulty and the test taker's ability. It is also hypothesized that better predictive validity of the CCAS in self-care of persons…

  15. Evaluation of betahistine for the prevention of seasickness: effect on vestibular function, psychomotor performance and efficacy at sea.

    PubMed

    Gordon, Carlos R; Doweck, Ilana; Nachum, Zohar; Gonen, Adi; Spitzer, Orna; Shupak, Avi

    2003-01-01

    Betahistine was evaluated for the prevention of seasickness in a laboratory and sea study. The effect of 48 mg betahistine on the vestibulo-ocular reflex (VOR) and on psychomotor performance was evaluated in twelve young healthy subjects in a double-blind, placebo controlled, randomized, crossover design. The vestibulo-ocular reflex was evaluated by the Sinusoidal Harmonic Acceleration (SHA) test at frequencies of 0.01, 0.02, 0.04, 0.08 and 0.16 Hz. Psychomotor performance was assessed by both computerized and paper and pencil test batteries. No significant differences in VOR gain or phase were found between betahistine and placebo treatment for any of the frequencies tested. No significant differences were found between treatments for any of the psychomotor performance tests or other possible side effects. The effect of 48 mg betahistine on seasickness severity was evaluated in 83 subjects during a voyage in rough seas. Betahistine had a borderline non-statistically significant effect on the prevention of seasickness in comparison with placebo (p = 0.053), with no notable side effects. Although our results are insufficient to recommend betahistine as an anti-seasickness drug, further studies are required to determine its possible effectiveness in less provocative motion sickness situations.

  16. International Ultraviolet Explorer (IUE) Battery History and Performance

    NASA Technical Reports Server (NTRS)

    Rao, Gopalskrishna M.; Tiller, Smith E.

    1999-01-01

    The "International Ultraviolet Explorer (IUE) Battery History and Performance" report provides the information on the cell/battery design, battery performance during the thirty eight (38) solar eclipse seasons and the end-of-life test data. It is noteworthy that IUE spacecraft was an in-house project and that the batteries were designed, fabricated and tested (Qualification and Acceptance) at the Goddard Space Flight Center. A detailed information is given on the cell and battery design criteria and the designs, on the Qualification and the Acceptance tests, and on the cell life cycling tests. The environmental, thermal, and vibration tests were performed on the batteries at the battery level as well as with the interface on the spacecraft. The telemetry data were acquired, analyzed, and trended for various parameters over the mission life. Rigorous and diligent battery management programs were developed and implemented from time to time to extend the mission life over eighteen plus years. Prior to the termination of spacecraft operation, special tests were conducted to check the battery switching operation, battery residual capacity, third electrode performance and battery impedance.

  17. The 2004 NASA Aerospace Battery Workshop

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Topics covered include: Super NiCd(TradeMark) Energy Storage for Gravity Probe-B Relativity Mission; Hubble Space Telescope 2004 Battery Update; The Development of Hermetically Sealed Aerospace Nickel-Metal Hydride Cell; Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System; Cell Equalization of Lithium-Ion Cells; The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics; Identification and Treatment of Lithium Battery Cell Imbalance under Flight Conditions; Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers; Cell Over Voltage Protection and Balancing Circuit of the Lithium-Ion Battery; Lithium-Ion Battery Electronics for Aerospace Applications; Lithium-Ion Cell Charge Control Unit; Lithium Ion Battery Cell Bypass Circuit Test Results at the U.S. Naval Research Laboratory; High Capacity Battery Cell By-Pass Switches: High Current Pulse Testing of Lithium-Ion; Battery By-Pass Switches to Verify Their Ability to Withstand Short-Circuits; Incorporation of Physics-Based, Spatially-Resolved Battery Models into System Simulations; A Monte Carlo Model for Li-Ion Battery Life Projections; Thermal Behavior of Large Lithium-Ion Cells; Thermal Imaging of Aerospace Battery Cells; High Rate Designed 50 Ah Li-Ion Cell for LEO Applications; Evaluation of Corrosion Behavior in Aerospace Lithium-Ion Cells; Performance of AEA 80 Ah Battery Under GEO Profile; LEO Li-Ion Battery Testing; A Review of the Feasibility Investigation of Commercial Laminated Lithium-Ion Polymer Cells for Space Applications; Lithium-Ion Verification Test Program; Panasonic Small Cell Testing for AHPS; Lithium-Ion Small Cell Battery Shorting Study; Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles; Update on Development of Lithium-Ion Cells for Space Applications at JAXA; Foreign Comparative Technology: Launch Vehicle Battery Cell Testing; 20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit; Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft; and Evaluation of the Effects of DoD and Charge Rate on a LEO Optimized 50 Ah Li-Ion Aerospace Cell.

  18. A Comparison of Item Selection Procedures Using Different Ability Estimation Methods in Computerized Adaptive Testing Based on the Generalized Partial Credit Model

    ERIC Educational Resources Information Center

    Ho, Tsung-Han

    2010-01-01

    Computerized adaptive testing (CAT) provides a highly efficient alternative to the paper-and-pencil test. By selecting items that match examinees' ability levels, CAT not only can shorten test length and administration time but it can also increase measurement precision and reduce measurement error. In CAT, maximum information (MI) is the most…

  19. Sequential Computerized Mastery Tests--Three Simulation Studies

    ERIC Educational Resources Information Center

    Wiberg, Marie

    2006-01-01

    A simulation study of a sequential computerized mastery test is carried out with items modeled with the 3 parameter logistic item response theory model. The examinees' responses are either identically distributed, not identically distributed, or not identically distributed together with estimation errors in the item characteristics. The…

  20. 2007 Nissan Altima-2351 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of on-road accelerated testing. This report documents the battery testing performed and the battery testing results for the 2007 Nissan Altima HEV, number 2351 (VIN 1N4CL21E87C172351). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec). The Idaho National Laboratory and eTec conduct the AVTA for DOE’s Vehicle Technologies Program.

  1. Testing activities at the National Battery Test Laboratory

    NASA Astrophysics Data System (ADS)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  2. Development of a Computerized In-Basket Exercise for the Classroom: A Sales Management Example

    ERIC Educational Resources Information Center

    Pearson, Michael M.; Barnes, John W.; Onken, Marina H.

    2006-01-01

    This article follows the development of a sales management in-basket exercise for use in the classroom. The authors have computerized the exercise and added features to allow for additional and more quantitative input from the students. The exercise has evolved and been tested in numerous classroom situations. The computerized in-basket exercise…

  3. Assessment of cognition in early dementia

    PubMed Central

    Silverberg, Nina B.; Ryan, Laurie M.; Carrillo, Maria C.; Sperling, Reisa; Petersen, Ronald C.; Posner, Holly B.; Snyder, Peter J.; Hilsabeck, Robin; Gallagher, Michela; Raber, Jacob; Rizzo, Albert; Possin, Katherine; King, Jonathan; Kaye, Jeffrey; Ott, Brian R.; Albert, Marilyn S.; Wagster, Molly V.; Schinka, John A.; Cullum, C. Munro; Farias, Sarah T.; Balota, David; Rao, Stephen; Loewenstein, David; Budson, Andrew E.; Brandt, Jason; Manly, Jennifer J.; Barnes, Lisa; Strutt, Adriana; Gollan, Tamar H.; Ganguli, Mary; Babcock, Debra; Litvan, Irene; Kramer, Joel H.; Ferman, Tanis J.

    2012-01-01

    Better tools for assessing cognitive impairment in the early stages of Alzheimer’s disease (AD) are required to enable diagnosis of the disease before substantial neurodegeneration has taken place and to allow detection of subtle changes in the early stages of progression of the disease. The National Institute on Aging and the Alzheimer’s Association convened a meeting to discuss state of the art methods for cognitive assessment, including computerized batteries, as well as new approaches in the pipeline. Speakers described research using novel tests of object recognition, spatial navigation, attentional control, semantic memory, semantic interference, prospective memory, false memory and executive function as among the tools that could provide earlier identification of individuals with AD. In addition to early detection, there is a need for assessments that reflect real-world situations in order to better assess functional disability. It is especially important to develop assessment tools that are useful in ethnically, culturally and linguistically diverse populations as well as in individuals with neurodegenerative disease other than AD. PMID:23559893

  4. Consequences of mild traumatic brain injury on information processing assessed with attention and short-term memory tasks.

    PubMed

    Malojcic, Branko; Mubrin, Zdenko; Coric, Bojana; Susnic, Mirica; Spilich, George J

    2008-01-01

    In this investigation, we explored the impact of mild traumatic brain injury (mTBI) upon short term or working memory and attention. The performance of 37 individuals with mTBI was compared with that of 53 age, sex and education-matched controls. All participants were staff members or individuals seeking medical care at a University hospital serving a large metropolitan area. A battery of computerized tests measured sustained visual attention, short-term memory (STM), simple reaction time, and decision time. Individuals with mTBI showed a performance deficit at sustained visual attention, STM scanning and a trend towards slowing in choice decision making. These observed changes in the cognitive performance of mTBI individuals are hypothesized to be a consequence of impaired central information processing. Our results suggest that mTBI can elicit meaningful cognitive deficits for several months post-injury. Additionally, we believe that the tasks employed in the current investigation demonstrate their utility for understanding cognitive deficits in mTBI individuals.

  5. Item Selection Criteria with Practical Constraints for Computerized Classification Testing

    ERIC Educational Resources Information Center

    Lin, Chuan-Ju

    2011-01-01

    This study compares four item selection criteria for a two-category computerized classification testing: (1) Fisher information (FI), (2) Kullback-Leibler information (KLI), (3) weighted log-odds ratio (WLOR), and (4) mutual information (MI), with respect to the efficiency and accuracy of classification decision using the sequential probability…

  6. A Comparative Study of Online Item Calibration Methods in Multidimensional Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Chen, Ping

    2017-01-01

    Calibration of new items online has been an important topic in item replenishment for multidimensional computerized adaptive testing (MCAT). Several online calibration methods have been proposed for MCAT, such as multidimensional "one expectation-maximization (EM) cycle" (M-OEM) and multidimensional "multiple EM cycles"…

  7. Computerized Adaptive Testing: Some Issues in Development.

    ERIC Educational Resources Information Center

    Orcutt, Venetia L.

    The emergence of enhanced capabilities in computer technology coupled with the growing body of knowledge regarding item response theory has resulted in the expansion of computerized adaptive test (CAT) utilization in a variety of venues. Newcomers to the field need a more thorough understanding of item response theory (IRT) principles, their…

  8. Variable-Length Computerized Adaptive Testing Based on Cognitive Diagnosis Models

    ERIC Educational Resources Information Center

    Hsu, Chia-Ling; Wang, Wen-Chung; Chen, Shu-Ying

    2013-01-01

    Interest in developing computerized adaptive testing (CAT) under cognitive diagnosis models (CDMs) has increased recently. CAT algorithms that use a fixed-length termination rule frequently lead to different degrees of measurement precision for different examinees. Fixed precision, in which the examinees receive the same degree of measurement…

  9. Best Design for Multidimensional Computerized Adaptive Testing with the Bifactor Model

    ERIC Educational Resources Information Center

    Seo, Dong Gi; Weiss, David J.

    2015-01-01

    Most computerized adaptive tests (CATs) have been studied using the framework of unidimensional item response theory. However, many psychological variables are multidimensional and might benefit from using a multidimensional approach to CATs. This study investigated the accuracy, fidelity, and efficiency of a fully multidimensional CAT algorithm…

  10. Application of the Bifactor Model to Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Seo, Dong Gi

    2011-01-01

    Most computerized adaptive tests (CAT) have been studied under the framework of unidimensional item response theory. However, many psychological variables are multidimensional and might benefit from using a multidimensional approach to CAT. In addition, a number of psychological variables (e.g., quality of life, depression) can be conceptualized…

  11. Computerized Adaptive Testing System Design: Preliminary Design Considerations.

    ERIC Educational Resources Information Center

    Croll, Paul R.

    A functional design model for a computerized adaptive testing (CAT) system was developed and presented through a series of hierarchy plus input-process-output (HIPO) diagrams. System functions were translated into system structure: specifically, into 34 software components. Implementation of the design in a physical system was addressed through…

  12. Considering the Use of General and Modified Assessment Items in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wyse, Adam E.; Albano, Anthony D.

    2015-01-01

    This article used several data sets from a large-scale state testing program to examine the feasibility of combining general and modified assessment items in computerized adaptive testing (CAT) for different groups of students. Results suggested that several of the assumptions made when employing this type of mixed-item CAT may not be met for…

  13. Precision-Based Item Selection for Exposure Control in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Carroll, Ian A.

    2017-01-01

    Item exposure control is, relative to adaptive testing, a nascent concept that has emerged only in the last two to three decades on an academic basis as a practical issue in high-stakes computerized adaptive tests. This study aims to implement a new strategy in item exposure control by incorporating the standard error of the ability estimate into…

  14. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    PubMed

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  15. Building the Vocational Phase of the Computerized Motor Skills Testing System for Use in the Electronics and Electrical Engineering Group and Hospitality Group

    ERIC Educational Resources Information Center

    Hsiao, Hsien-Sheng; Chen, Jyun-Chen; Hong, Kunde

    2016-01-01

    Technical and vocational education emphasizes the development and training of hand motor skills. However, some problems exist in the current career and aptitude tests in that they do not truly measure the hand motor skills. This study used the Nintendo Wii Remote Controller as the testing device in developing a set of computerized testing tools to…

  16. Potential use of battery packs from NCAP tested vehicles.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, Joshua; Orendorff, Christopher J.

    2013-10-01

    Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of accessmore » available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.« less

  17. C-TOC (Cognitive Testing on Computer): investigating the usability and validity of a novel self-administered cognitive assessment tool in aging and early dementia.

    PubMed

    Jacova, Claudia; McGrenere, Joanna; Lee, Hyunsoo S; Wang, William W; Le Huray, Sarah; Corenblith, Emily F; Brehmer, Matthew; Tang, Charlotte; Hayden, Sherri; Beattie, B Lynn; Hsiung, Ging-Yuek R

    2015-01-01

    Cognitive Testing on Computer (C-TOC) is a novel computer-based test battery developed to improve both usability and validity in the computerized assessment of cognitive function in older adults. C-TOC's usability was evaluated concurrently with its iterative development to version 4 in subjects with and without cognitive impairment, and health professional advisors representing different ethnocultural groups. C-TOC version 4 was then validated against neuropsychological tests (NPTs), and by comparing performance scores of subjects with normal cognition, Cognitive Impairment Not Dementia (CIND) and Alzheimer disease. C-TOC's language tests were validated in subjects with aphasic disorders. The most important usability issue that emerged from consultations with 27 older adults and with 8 cultural advisors was the test-takers' understanding of the task, particularly executive function tasks. User interface features did not pose significant problems. C-TOC version 4 tests correlated with comparator NPT (r=0.4 to 0.7). C-TOC test scores were normal (n=16)>CIND (n=16)>Alzheimer disease (n=6). All normal/CIND NPT performance differences were detected on C-TOC. Low computer knowledge adversely affected test performance, particularly in CIND. C-TOC detected impairments in aphasic disorders (n=11). In general, C-TOC had good validity in detecting cognitive impairment. Ensuring test-takers' understanding of the tasks, and considering their computer knowledge appear important steps towards C-TOC's implementation.

  18. Performance of the Lester battery charger in electric vehicles

    NASA Technical Reports Server (NTRS)

    Vivian, H. C.; Bryant, J. A.

    1984-01-01

    Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

  19. Air Force Phillips Laboratory Battery Program overview

    NASA Technical Reports Server (NTRS)

    House, Shaun

    1992-01-01

    Battery development and testing efforts at Phillips Laboratory fall into three main categories: nickel hydrogen, sodium sulfur, and solid state batteries. Nickel hydrogen work is broken down into a Low Earth Orbit (LEO) Life Test Program, a LEO Pulse Test Program, and a Hydrogen Embrittlement Investigation. Sodium sulfur work is broken down into a Geosynchronous Earth Orbit (GEO) Battery Flight Test and a Hot Launch Evaluation. Solid state polymer battery work consists of a GEO Battery Development Program, a Pulse Power Battery Small Business Innovation Research (SBIR), and an in-house evaluation of current generation laboratory cells. An overview of the program is presented.

  20. 2010 Toyota Prius VIN 0462 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN: JTDKN3DU2A5010462). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  1. 2010 Honda Insight VIN 0141 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H78AS010141). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  2. 2010 Toyota Prius VIN 6063 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN JTDKN3DU5A0006063). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  3. 2010 Honda Insight VIN 1748 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H59AS011748). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  4. 2010 Ford Fusion VIN 4757 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2010 Ford Fusion HEV (VIN: 3FADP0L34AR144757). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for themore » Vehicle Technologies Program of the U.S. Department of Energy.« less

  5. Cell overcharge testing inside sodium metal halide battery

    NASA Astrophysics Data System (ADS)

    Frutschy, Kris; Chatwin, Troy; Bull, Roger

    2015-09-01

    Testing was conducted to measure electrical performance and safety of the General Electric Durathon™ E620 battery module (600 V class 20 kWh) during cell overcharge. Data gathered from this test was consistent with SAE Electric Vehicle Battery Abuse Testing specification J2464 [1]. After cell overcharge failure and 24 A current flow for additional 60 minutes, battery was then discharged at 7.5 KW average power to 12% state of charge (SOC) and recharged back to 100% SOC. This overcharging test was performed on two cells. No hydrogen chloride (HCl) gas was detected during front cell (B1) test, and small amount (6.2 ppm peak) was measured outside the battery after center cell (F13) overcharge. An additional overcharge test was performed per UL Standard 1973 - Batteries for Use in Light Electric Rail (LER) Applications and Stationary Applications[2]. With the battery at 11% SOC and 280 °C float temperature, an individual cell near the front (D1) was deliberately imbalanced by charging it to 62% SOC. The battery was then recharged to 100% SOC. In all three tests, the battery cell pack was stable and individual cell failure did not propagate to other cells. Battery discharge performance, charge performance, and electrical isolation were normal after all three tests.

  6. Testing primates with joystick-based automated apparatus - Lessons from the Language Research Center's Computerized Test System

    NASA Technical Reports Server (NTRS)

    Washburn, David A.; Rumbaugh, Duane M.

    1992-01-01

    Nonhuman primates provide useful models for studying a variety of medical, biological, and behavioral topics. Four years of joystick-based automated testing of monkeys using the Language Research Center's Computerized Test System (LRC-CTS) are examined to derive hints and principles for comparable testing with other species - including humans. The results of multiple parametric studies are reviewed, and reliability data are presented to reveal the surprises and pitfalls associated with video-task testing of performance.

  7. Validity and Reliability of Baseline Testing in a Standardized Environment.

    PubMed

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Batteries for Electric Vehicles

    NASA Technical Reports Server (NTRS)

    Conover, R. A.

    1985-01-01

    Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.

  9. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    PubMed

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Laboratory testing of the (Japan Storage Battery) traction batteries GS E75A and GS E150H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report describes the testing of the GS E75A and GS E150H flooded lead-acid 12-volt traction batteries and compares the selected batteries to U.S.-made electric vehicle batteries. The results and conclusions of the testing are presented.

  11. Ampule tests to simulate glass corrosion in ambient temperature lithium batteries. Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Douglas, S.C.; Bunker, B.C.; Crafts, C.C.

    1984-06-01

    Glass corrosion in battery headers has been found to limit the shelf life of ambient temperature lithium batteries. Glass corrosion can lead to loss of battery electrolytes or to shorts across the conductive corrosion product. Tests have been conducted which simulate the corrosive environment in a battery by sealing headers attached to lithium metal into Pyrex ampules containing battery electrolyte. Using the ampule test, glass corrosion kinetics have been determined at 70/sup 0/C for the Li/SO/sub 2/, Li/SOCl/sub 2/, and Li/SOCl/sub 2/ + BrCl battery systems. Test results indicate that corrosion of commercial glass compositions is extensive in all electrolytesmore » tested, resulting in predicted battery failures after several months. Sandia's TA-23 glass corrodes at a much slower rate, indicating a projected battery lifetime of over five years in the Li/SO/sub 2/ system. Test results reveal that corrosion kinetics are sensitive to header polarization, stress, and configuration as well as glass composition.« less

  12. Reliability and Validity of the Computerized Revised Token Test: Comparison of Reading and Listening Versions in Persons with and without Aphasia

    ERIC Educational Resources Information Center

    McNeil, Malcolm R.; Pratt, Sheila R.; Szuminsky, Neil; Sung, Jee Eun; Fossett, Tepanta R. D.; Fassbinder, Wiltrud; Lim, Kyoung Yuel

    2015-01-01

    Purpose: This study assessed the reliability and validity of intermodality associations and differences in persons with aphasia (PWA) and healthy controls (HC) on a computerized listening and 3 reading versions of the Revised Token Test (RTT; McNeil & Prescott, 1978). Method: Thirty PWA and 30 HC completed the test versions, including a…

  13. Discovering Visual Scanning Patterns in a Computerized Cancellation Test

    ERIC Educational Resources Information Center

    Huang, Ho-Chuan; Wang, Tsui-Ying

    2013-01-01

    The purpose of this study was to develop an attention sequential mining mechanism for investigating the sequential patterns of children's visual scanning process in a computerized cancellation test. Participants had to locate and cancel the target amongst other non-targets in a structured form, and a random form with Chinese stimuli. Twenty-three…

  14. A Framework for the Development of Computerized Adaptive Tests

    ERIC Educational Resources Information Center

    Thompson, Nathan A.; Weiss, David J.

    2011-01-01

    A substantial amount of research has been conducted over the past 40 years on technical aspects of computerized adaptive testing (CAT), such as item selection algorithms, item exposure controls, and termination criteria. However, there is little literature providing practical guidance on the development of a CAT. This paper seeks to collate some…

  15. SimulCAT: Windows Software for Simulating Computerized Adaptive Test Administration

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2012-01-01

    Most, if not all, computerized adaptive testing (CAT) programs use simulation techniques to develop and evaluate CAT program administration and operations, but such simulation tools are rarely available to the public. Up to now, several software tools have been available to conduct CAT simulations for research purposes; however, these existing…

  16. Firestar-"D": Computerized Adaptive Testing Simulation Program for Dichotomous Item Response Theory Models

    ERIC Educational Resources Information Center

    Choi, Seung W.; Podrabsky, Tracy; McKinney, Natalie

    2012-01-01

    Computerized adaptive testing (CAT) enables efficient and flexible measurement of latent constructs. The majority of educational and cognitive measurement constructs are based on dichotomous item response theory (IRT) models. An integral part of developing various components of a CAT system is conducting simulations using both known and empirical…

  17. A Feedback Control Strategy for Enhancing Item Selection Efficiency in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Weissman, Alexander

    2006-01-01

    A computerized adaptive test (CAT) may be modeled as a closed-loop system, where item selection is influenced by trait level ([theta]) estimation and vice versa. When discrepancies exist between an examinee's estimated and true [theta] levels, nonoptimal item selection is a likely result. Nevertheless, examinee response behavior consistent with…

  18. Dual-Objective Item Selection Criteria in Cognitive Diagnostic Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Kang, Hyeon-Ah; Zhang, Susu; Chang, Hua-Hua

    2017-01-01

    The development of cognitive diagnostic-computerized adaptive testing (CD-CAT) has provided a new perspective for gaining information about examinees' mastery on a set of cognitive attributes. This study proposes a new item selection method within the framework of dual-objective CD-CAT that simultaneously addresses examinees' attribute mastery…

  19. Young Learners' Response Processes When Taking Computerized Tasks for Speaking Assessment

    ERIC Educational Resources Information Center

    Lee, Shinhye; Winke, Paula

    2018-01-01

    We investigated how young language learners process their responses on and perceive a computer-mediated, timed speaking test. Twenty 8-, 9-, and 10-year-old non-native English-speaking children (NNSs) and eight same-aged, native English-speaking children (NSs) completed seven computerized sample TOEFL® Primary™ speaking test tasks. We investigated…

  20. Optimal Item Pool Design for a Highly Constrained Computerized Adaptive Test

    ERIC Educational Resources Information Center

    He, Wei

    2010-01-01

    Item pool quality has been regarded as one important factor to help realize enhanced measurement quality for the computerized adaptive test (CAT) (e.g., Flaugher, 2000; Jensema, 1977; McBride & Wise, 1976; Reckase, 1976; 2003; van der Linden, Ariel, & Veldkamp, 2006; Veldkamp & van der Linden, 2000; Xing & Hambleton, 2004). However, studies are…

  1. The Work Disability Functional Assessment Battery (WD-FAB): Feasibility and Psychometric Properties

    PubMed Central

    Meterko, Mark; Marfeo, Elizabeth E.; McDonough, Christine M.; Jette, Alan M.; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E.; Chan, Leighton

    2015-01-01

    Objectives To assess the feasibility and psychometric properties of eight scales covering two domains of the newly developed Work Disability Functional Assessment Battery (WD-FAB): physical function (PF) and behavioral health (BH) function. Design Cross-sectional. Setting Community. Participants Adults unable to work due to a physical (n=497) or mental (n=476) disability. Interventions None. Main Outcome Measures Each disability group responded to a survey consisting of the relevant WD-FAB scales and existing measures of established validity. The WD-FAB scales were evaluated with regard to data quality (score distribution; percent “I don’t know” responses), efficiency of administration (number of items required to achieve reliability criterion; time required to complete the scale) by computerized adaptive testing (CAT), and measurement accuracy as tested by person fit. Construct validity was assessed by examining both convergent and discriminant correlations between the WD-FAB scales and scores on same-domain and cross-domain established measures. Results Data quality was good and CAT efficiency was high across both WD-FAB domains. Measurement accuracy was very good for the PF scales; BH scales demonstrated more variability. Construct validity correlations, both convergent and divergent, between all WD-FAB scales and established measures were in the expected direction and range of magnitude. Conclusions The data quality, CAT efficacy, person fit and construct validity of the WD-FAB scales were well supported and suggest that the WD-FAB could be used to assess physical and behavioral health function related to work disability. Variation in scale performance suggests the need for future work on item replenishment and refinement, particularly regarding the Self-Efficacy scale. PMID:25528263

  2. A neuropsychological assessment, using computerized battery tests (CANTAB), in children with benign rolandic epilepsy before AED therapy.

    PubMed

    Vinţan, M A; Palade, S; Cristea, A; Benga, I; Muresanu, D F

    2012-02-22

    Benign rolandic epilepsy (BRE) is a form of partial idiopathic epilepsy according to the International League Against Epilepsy (ILAE) syndromes classification (1989). Recent studies have identified cases of BRE that do not meet the initial definition of 'benign'; these included reports of cases with specific cognitive deficits. It is still a matter of debate, whether these deficits are due to epilepsy per se, to treatment or other associated factors. The aim of this study was to evaluate if BRE children have cognitive deficits at the onset of their seizures, prior to their participation in any anti-epileptic drug therapy (AED). We performed a neuropsychological assessment of 18 BRE children compared with a corresponding age-matched control group. We used the Cambridge Neuropsychological Test Automated Battery (CANTAB). Subjects were at their first neurological evaluation, before any AED therapy. We assessed: visual memory, induction and executive functions. In our group, the BRE children performed comparably with the control children for the induction and executive functions. Substantial differences were identified for the visual memory subtests: PRM percent correct (t = -2.58, p = 0.01) and SRM percent correct (t = -2.73, p = 0.01). Age of seizure onset had a negative impact on the visual memory subtest performances (PRM mean correct latency). We found significant correlations between the different CANTAB subtests results and characteristics of the centrotemporal spikes (CTS). Our results are consistent with the findings of other similar studies. This form of epilepsy is associated with subtle neuropsychological deficits, present at seizure onset. Neuropsychological deficits identified, suggest a more diffuse brain involvement in the epileptiform process.

  3. Neuropsychological mechanisms of Digit Symbol Substitution Test impairment in Asperger Disorder.

    PubMed

    Yoran-Hegesh, Roni; Kertzman, Semion; Vishne, Tali; Weizman, Abraham; Kotler, Moshe

    2009-03-31

    Our aim was to investigate the neurocognitive mechanisms recruited by adolescents with Asperger Disorder (AD), in comparison to controls, and to detect the underlying mechanisms during the complex information processing required for the performance of the Digit Symbol Substitution Test (DSST). Male adolescents (n=23; mean age 15.1+/-3.6 years) with a DSM-IV diagnosis of AD were compared with a normal male control group with similar demographic characteristics (n=43; mean age: 15.1+/-3.6 years). A computerized neurocognitive battery was administered and included: Inspection Time (IT), Finger Tapping Test (FTT), Simple Reaction Time (SRT), Choice Reaction Time (CRT), Digit Running task (DRT), Stroop test and Digit Symbol Substitution Test (DSST). Adolescents with AD performed significantly worse than controls on the DSST. This impaired DSST performance was related to cognitive mechanisms different from those employed by normal controls. Motor slowness and inability to deal with increased amounts of information affected the performance of the AD group, while shifting of attention was the limiting factor in the controls. Both groups were similarly dependent on response selection. This study demonstrated differences in performance in complex cognitive tasks between adolescents with AD and normal controls that may be related to differences in neurocognitive mechanisms underlying information processing. Future neuroimaging studies are needed to clarify the neural network involved in the differences in cognitive performance between AD subjects and normal controls.

  4. Psychomotor performance during a 28 day head-down tilt with and without lower body negative pressure

    NASA Astrophysics Data System (ADS)

    Traon, A. Pavy-le; de Feneyrols, A. Rous; Cornac, A.; Abdeseelam, R.; N'uygen, D.; Lazerges, M.; Güell, A.; Bes, A.

    Several factors may affect psychomotor performance in space: sensory-motor changes, sleep disturbances, psychological modifications induced by the social isolation and confinement. However, psychomotor performance is difficult to assess. A battery of standardized and computerized tests, so-called "Automated Portable Test System" (APTS) was devised to ascertain the cognitive, perceptive and motor abilities and their possible fluctuations according to environmental effects. Antiorthostatic bedrest, often used to simulate weightlessness, (particularly cardiovascular modifications) also constitutes a situation of social confinement and isolation. During two bedrest experiments (with head-down tilt of -6°) of 28 days each, we intended to assess psychomotor performance of 6 males so as to determine whether: —on the one hand, it could be altered by remaining in decubitus; —on the other, the Lower Body Negative Pressure sessions, designed to prevent orthostatic intolerance back on Earth, could improve the performance. To accomplish this, part of the APTS tests as well as an automated perceptive attention test were performed. No downgrading of psychomotor performance was observed. On the contrary, the tasks were more accurately performed over time. In order to assess the experimental conditions on the acquisition phase, the learning curves were modelled. A beneficial effect of the LBNP sessions on simple tests involving the visual-motor coordination and attention faculties can only be regarded as a mere trend. Methods used in this experiment are also discussed.

  5. Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

    NASA Astrophysics Data System (ADS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gahn, Randall F.

    1989-12-01

    In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

  6. Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

    NASA Technical Reports Server (NTRS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gahn, Randall F.

    1989-01-01

    In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

  7. [The clinical economic analysis of the methods of ischemic heart disease diagnostics].

    PubMed

    Kalashnikov, V Iu; Mitriagina, S N; Syrkin, A L; Poltavskaia, M G; Sorokina, E G

    2007-01-01

    The clinical economical analysis was applied to assess the application of different techniques of ischemic heart disease diagnostics - the electro-cardiographic monitoring, the treadmill-testing, the stress-echo cardiographic with dobutamine, the single-photon computerized axial tomography with load, the multi-spiral computerized axial tomography with coronary arteries staining in patients with different initial probability of disease occurrence. In all groups, the best value of "cost-effectiveness" had the treadmill-test. The patients with low risk needed 17.4 rubles to precise the probability of ischemic heart disease occurrence at 1%. In the group with medium and high risk this indicator was 9.4 and 24.7 rubles correspondingly. It is concluded that to precise the probability of ischemic heart disease occurrence after tredmil-test in the patients with high probability it is appropriate to use the single-photon computerized axial tomography with load and in the case of patients with low probability the multi-spiral computerized axial tomography with coronary arteries staining.

  8. Computerized Cognitive Screen (CoCoSc): A Self-Administered Computerized Test for Screening for Cognitive Impairment in Community Social Centers.

    PubMed

    Wong, Adrian; Fong, Ching-Hang; Mok, Vincent Chung-Tong; Leung, Kam-Tat; Tong, Raymond Kai-Yu

    2017-01-01

    Computerized cognitive tests may serve as a preliminary, low-cost method to identify individuals with suspected cognitive impairment in the community. To develop a self-administered computerized test, namely the "Computerized Cognitive Screen (CoCoSc), Hong Kong version", for screening of individuals with cognitive impairment (CI) in community settings. The CoCoSc is a 15-min computerized cognitive screen covering memory, executive functions, orientation, attention and working memory, and prospective memory administered on a touchscreen computer. Individuals with CI and cognitively normal controls were administered the CoCoSc and the Montreal Cognitive Assessment (MoCA). Validity of the CoCoSc was assessed based on the relationship with the MoCA using Pearson correlation. Receiver operating characteristic curve (ROC) was used to examine the ability of the CoCoSc to differentiate CI from controls. Fifty-nine individuals with CI and 101 controls were recruited. Seventy-five (46.9%) participants had ≤6 years of education. Performance on the CoCoSc differed between normal and CI groups in both low and high education subgroups. Total scores of the CoCoSc and MoCA were significantly correlated (r = 0.71, p < 0.001). The area under ROC was 0.78, p < 0.001 for the CoCoSc total score in differentiating the CI group from the cognitively normal group. A cut-off of ≤30 on the CoCoSc was associated with a sensitivity of 0.78 and specificity of 0.69. The CoCoSc was well accepted by attendees of community social centers. The CoCoSc is a promising computerized cognitive screen for self-administration in community social centers. It is feasible for testing individuals with high or low education levels.

  9. SMS/GOES cell and battery data analysis report

    NASA Technical Reports Server (NTRS)

    Armantrout, J. D.

    1977-01-01

    The nickel-cadmium battery design developed for the Synchronous Meteorological Satellite (SMS) and Geostationary Operational Environmental Satellite (GOES) provided background and guidelines for future development, manufacture, and application of spacecraft batteries. SMS/GOES battery design, development, qualification testing, acceptance testing, and life testing/mission performance characteristics were evaluated for correlation with battery cell manufacturing process variables.

  10. Life test of a nickel cadmium battery with a protection/reconditioning circuit

    NASA Technical Reports Server (NTRS)

    Lanier, J. R., Jr.; Bush, J. R., Jr.

    1981-01-01

    Results are discussed for a Ni-Cd battery test over a period of 8 years, 2 months and 44,213 simulated low Earth orbits. The battery cells were protected against overdischarge and reversal at discharge rates up to 25 amperes (1.25C) by a battery protection and reconditioning circuit. The circuit performed flawlessly during the test, and proved its value, both as a battery reconditioner and a cell protection device. Battery cell failures are also discussed. The test demonstrated the viability of using Ni-Cd batteries at depth-of-discharge up to 25 percent for over 5 years in a low Earth orbit.

  11. Testing of the Eagle-Picher nickel-iron, the Globe ISOA lead-acid, and the Westinghouse nickel-iron battery subsystems in an electric-vehicle environment

    NASA Technical Reports Server (NTRS)

    Hewitt, R.; Bryant, J.

    1982-01-01

    Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.

  12. Testing of sealed lead-acid batteries

    NASA Astrophysics Data System (ADS)

    Bush, D. M.; Sealey, J. D.; Miller, D. W.

    1984-02-01

    Sealed lead acid batteries under development were tested. The goal was to develop a totally maintenance free sealed lead acid battery capable of deep discharge operation in a photovoltaic power system. Sealed lead acid batteries and a group of conventional, flooded lead acid batteries were exposed to a matrix test plan, with some approaching 1000 cycles. This performance was achieved with the standard National Electrical Manufacturers' Association cycle test, and the partial state of charge cycle test. Modes of failure are investigated.

  13. Allium sativum L. Improves Visual Memory and Attention in Healthy Human Volunteers

    PubMed Central

    Tasnim, Sara; Haque, Parsa Sanjana; Bari, Md. Sazzadul; Hossain, Md. Monir; Islam, Sardar Mohd. Ashraful; Shahriar, Mohammad; Bhuiyan, Mohiuddin Ahmed; Bin Sayeed, Muhammad Shahdaat

    2015-01-01

    Studies have shown that Allium sativum L. (AS) protects amyloid-beta peptide-induced apoptosis, prevents oxidative insults to neurons and synapses, and thus prevent Alzheimer's disease progression in experimental animals. However, there is no experimental evidence in human regarding its putative role in memory and cognition. We have studied the effect of AS consumption by healthy human volunteers on visual memory, verbal memory, attention, and executive function in comparison to control subjects taking placebo. The study was conducted over five weeks and twenty volunteers of both genders were recruited and divided randomly into two groups: A (AS) and B (placebo). Both groups participated in the 6 computerized neuropsychological tests of the Cambridge Neuropsychological Test Automated Battery (CANTAB) twice: at the beginning and after five weeks of the study. We found statistically significant difference (p < 0.05) in several parameters of visual memory and attention due to AS ingestion. We also found statistically nonsignificant (p > 0.05) beneficial effects on verbal memory and executive function within a short period of time among the volunteers. Study for a longer period of time with patients suffering from neurodegenerative diseases might yield more relevant results regarding the potential therapeutic role of AS. PMID:26351508

  14. Prosody recognition and audiovisual emotion matching in schizophrenia: the contribution of cognition and psychopathology.

    PubMed

    Castagna, Filomena; Montemagni, Cristiana; Maria Milani, Anna; Rocca, Giuseppe; Rocca, Paola; Casacchia, Massimo; Bogetto, Filippo

    2013-02-28

    This study aimed to evaluate the ability to decode emotion in the auditory and audiovisual modality in a group of patients with schizophrenia, and to explore the role of cognition and psychopathology in affecting these emotion recognition abilities. Ninety-four outpatients in a stable phase and 51 healthy subjects were recruited. Patients were assessed through a psychiatric evaluation and a wide neuropsychological battery. All subjects completed the comprehensive affect testing system (CATS), a group of computerized tests designed to evaluate emotion perception abilities. With respect to the controls, patients were not impaired in the CATS tasks involving discrimination of nonemotional prosody, naming of emotional stimuli expressed by voice and judging the emotional content of a sentence, whereas they showed a specific impairment in decoding emotion in a conflicting auditory condition and in the multichannel modality. Prosody impairment was affected by executive functions, attention and negative symptoms, while deficit in multisensory emotion recognition was affected by executive functions and negative symptoms. These emotion recognition deficits, rather than being associated purely with emotion perception disturbances in schizophrenia, are affected by core symptoms of the illness. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Field evaluation of a behavioral test battery for DWI

    DOT National Transportation Integrated Search

    1983-09-01

    This paper presents initial findings from a recently conducted field evaluation of a sobriety test battery. Police officers from four jurisdictions were trained in the use of the sobriety test battery. They then administered the battery to drivers st...

  16. Enhancing effects of nicotine and impairing effects of scopolamine on distinct aspects of performance in computerized attention and working memory tasks in marmoset monkeys.

    PubMed

    Spinelli, Simona; Ballard, Theresa; Feldon, Joram; Higgins, Guy A; Pryce, Christopher R

    2006-08-01

    With the CAmbridge Neuropsychological Test Automated Battery (CANTAB), computerized neuropsychological tasks can be presented on a touch-sensitive computer screen, and this system has been used to assess cognitive processes in neuropsychiatric patients, healthy volunteers, and species of non-human primate, primarily the rhesus macaque and common marmoset. Recently, we reported that the common marmoset, a small-bodied primate, can be trained to a high and stable level of performance on the CANTAB five-choice serial reaction time (5-CSRT) task of attention, and a novel task of working memory, the concurrent delayed match-to-position (CDMP) task. Here, in order to increase understanding of the specific cognitive demands of these tasks and the importance of acetylcholine to their performance, the effects of systemic delivery of the muscarinic receptor antagonist scopolamine and the nicotinic receptor agonist nicotine were studied. In the 5-CSRT task, nicotine enhanced performance in terms of increased sustained attention, whilst scopolamine led to increased omissions despite a high level of orientation to the correct stimulus location. In the CDMP task, scopolamine impaired performance at two stages of the task that differ moderately in terms of memory retention load but both of which are likely to require working memory, including interference-coping, abilities. Nicotine tended to enhance performance at the long-delay stage specifically but only against a background of relatively low baseline performance. These data are consistent with a dissociation of the roles of muscarinic and nicotinic cholinergic receptors in the regulation of both sustained attention and working memory in primates.

  17. International Space Station Lithium-Ion Main Battery Thermal Runaway Propagation Test

    NASA Technical Reports Server (NTRS)

    Dalton, Penni J.; North, Tim

    2017-01-01

    In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the aging Ni-H2 batteries on the primary Electric Power System (EPS). After the Boeing 787 Li-Ion battery fires, the NASA Engineering and Safety Center (NESC) Power Technical Discipline Team was tasked by ISS to investigate the possibility of Thermal Runaway Propagation (TRP) in all Li-Ion batteries used on the ISS. As part of that investigation, NESC funded a TRP test of an ISS EPS non-flight Li-Ion battery. The test was performed at NASA White Sands Test Facility in October 2016. This paper will discuss the work leading up to the test, the design of the test article, and the test results.

  18. Cognitive Training Program to Improve Working Memory in Older Adults with MCI.

    PubMed

    Hyer, Lee; Scott, Ciera; Atkinson, Mary Michael; Mullen, Christine M; Lee, Anna; Johnson, Aaron; Mckenzie, Laura C

    2016-01-01

    Deficits in working memory (WM) are associated with age-related decline. We report findings from a clinical trial that examined the effectiveness of Cogmed, a computerized program that trains WM. We compare this program to a Sham condition in older adults with Mild Cognitive Impairment (MCI). Older adults (N = 68) living in the community were assessed. Participants reported memory impairment and met criteria for MCI, either by poor delayed memory or poor performance in other cognitive areas. The Repeatable Battery for the Assessment of Neuropsychological Status (RBANS, Delayed Memory Index) and the Clinical Dementia Rating scale (CDR) were utilized. All presented with normal Mini Mental State Exams (MMSE) and activities of daily living (ADLs). Participants were randomized to Cogmed or a Sham computer program. Twenty-five sessions were completed over five to seven weeks. Pre, post, and follow-up measures included a battery of cognitive measures (three WM tests), a subjective memory scale, and a functional measure. Both intervention groups improved over time. Cogmed significantly outperformed Sham on Span Board and exceeded in subjective memory reports at follow-up as assessed by the Cognitive Failures Questionnaire (CFQ). The Cogmed group demonstrated better performance on the Functional Activities Questionnaire (FAQ), a measure of adjustment and far transfer, at follow-up. Both groups, especially Cogmed, enjoyed the intervention. Results suggest that WM was enhanced in both groups of older adults with MCI. Cogmed was better on one core WM measure and had higher ratings of satisfaction. The Sham condition declined on adjustment.

  19. 2011 Chevrolet Volt VIN 0815 Plug-In Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk; Jeffrey Wishart

    2013-07-01

    The U.S. Department of Energy (DOE) Advanced Vehicle Testing Activity (AVTA) program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on plug-in hybrid electric vehicles (PHEVs), including testing the PHEV batteries when both the vehicles and batteries are new and at the conclusion of 12,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Chevrolet Volt PHEV (VIN 1G1RD6E48BU100815). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec) dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on themore » AVTA for the Vehicle Technologies Program of the DOE.« less

  20. Detection of Acute and Long-Term Effects of Concussion: Dual-Task Gait Balance Control Versus Computerized Neurocognitive Test.

    PubMed

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2018-02-16

    To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits alone. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Vestibular rehabilitation outcomes in chronic vertiginous patients through computerized dynamic visual acuity and Gaze stabilization test.

    PubMed

    Badaracco, Carlo; Labini, Francesca Sylos; Meli, Annalisa; De Angelis, Ezio; Tufarelli, Davide

    2007-09-01

    To evaluate the efficiency of the rehabilitative protocols in patients with labyrinthine hypofunction, focusing on computerized dynamic visual acuity test (DVAt) and Gaze stabilization test (GST) specifically evaluating the vestibulo-oculomotor reflex (VOR) changes due to vestibular rehabilitation. Consecutive sample study. Day hospital in Ears, Nose, and Throat Rehabilitation Unit. Thirty-two patients with chronic dizziness with a mean age of 60.74 years. Patients performed one cycle of 12 daily rehabilitation sessions (2 h each) consisting of exercises aimed at improving VOR gain. The rehabilitation program included substitutional and/or habitudinal exercises, exercises on a stability platform, and exercises on a moving footpath with rehabilitative software. Dizziness Handicap Inventory and Activities-specific Balance Confidence Scale. Computerized dynamic posturography, computerized DVAt, and GST. The patients significantly improved in all the tests. Vestibular rehabilitation improved the quality of life by reducing the handicap index and improving the ability in everyday tasks. The recovery of the vestibular-ocular reflex and vestibular-spinal reflex efficiency was objectively proven by instrumental testing. The DVAt and the GST allow to objectively quantify the fixation ability at higher frequencies and speeds (main VOR function). Moreover, these new parameters permit to completely evaluate vestibular rehabilitation outcomes, adding new information to the generally used tests that only assess vestibulospinal reflex.

  2. Sodium-sulfur battery flight experiment definition study

    NASA Technical Reports Server (NTRS)

    Chang, Rebecca; Minck, Robert

    1990-01-01

    Sodium-sulfur batteries are considered to be one of the most likely battery systems for space applications. Compared with the Ni-H2 or Ni-Co battery systems, Na-S batteries offer a mass reduction by a factor of 2 to 4, representing significant launch cost savings or increased payload mass capabilities. The Na-S battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte; the transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. This paper describes five tests identified for the Na-S battery flight experiment definition study, which include the cell characterization test, the reactant distribution test, the current/temperature distribution test, the freeze/thaw test, and the multicell LEO test. A schematic diagram of Na-S cell is included.

  3. Testing Conducted for Lithium-Ion Cell and Battery Verification

    NASA Technical Reports Server (NTRS)

    Reid, Concha M.; Miller, Thomas B.; Manzo, Michelle A.

    2004-01-01

    The NASA Glenn Research Center has been conducting in-house testing in support of NASA's Lithium-Ion Cell Verification Test Program, which is evaluating the performance of lithium-ion cells and batteries for NASA mission operations. The test program is supported by NASA's Office of Aerospace Technology under the NASA Aerospace Flight Battery Systems Program, which serves to bridge the gap between the development of technology advances and the realization of these advances into mission applications. During fiscal year 2003, much of the in-house testing effort focused on the evaluation of a flight battery originally intended for use on the Mars Surveyor Program 2001 Lander. Results of this testing will be compared with the results for similar batteries being tested at the Jet Propulsion Laboratory, the Air Force Research Laboratory, and the Naval Research Laboratory. Ultimately, this work will be used to validate lithium-ion battery technology for future space missions. The Mars Surveyor Program 2001 Lander battery was characterized at several different voltages and temperatures before life-cycle testing was begun. During characterization, the battery displayed excellent capacity and efficiency characteristics across a range of temperatures and charge/discharge conditions. Currently, the battery is undergoing lifecycle testing at 0 C and 40-percent depth of discharge under low-Earth-orbit (LEO) conditions.

  4. Multistage Computerized Adaptive Testing with Uniform Item Exposure

    ERIC Educational Resources Information Center

    Edwards, Michael C.; Flora, David B.; Thissen, David

    2012-01-01

    This article describes a computerized adaptive test (CAT) based on the uniform item exposure multi-form structure (uMFS). The uMFS is a specialization of the multi-form structure (MFS) idea described by Armstrong, Jones, Berliner, and Pashley (1998). In an MFS CAT, the examinee first responds to a small fixed block of items. The items comprising…

  5. Effects of Content Balancing and Item Selection Method on Ability Estimation in Computerized Adaptive Tests

    ERIC Educational Resources Information Center

    Sahin, Alper; Ozbasi, Durmus

    2017-01-01

    Purpose: This study aims to reveal effects of content balancing and item selection method on ability estimation in computerized adaptive tests by comparing Fisher's maximum information (FMI) and likelihood weighted information (LWI) methods. Research Methods: Four groups of examinees (250, 500, 750, 1000) and a bank of 500 items with 10 different…

  6. Equating Computerized Adaptive Certification Examinations: The Board of Registry Series of Studies.

    ERIC Educational Resources Information Center

    Lunz, Mary E.; Bergstrom, Betty A.

    The Board of Registry (BOR) certifies medical technologists and other laboratory personnel. The BOR has studied adaptive testing for over 6 years and now administers all 17 BOR certification examinations using computerized adaptive testing (CAT). This paper presents an overview of the major research efforts from 1989 to the present related to test…

  7. Multiple Maximum Exposure Rates in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Ramon Barrada, Juan; Veldkamp, Bernard P.; Olea, Julio

    2009-01-01

    Computerized adaptive testing is subject to security problems, as the item bank content remains operative over long periods and administration time is flexible for examinees. Spreading the content of a part of the item bank could lead to an overestimation of the examinees' trait level. The most common way of reducing this risk is to impose a…

  8. A Semiparametric Model for Jointly Analyzing Response Times and Accuracy in Computerized Testing

    ERIC Educational Resources Information Center

    Wang, Chun; Fan, Zhewen; Chang, Hua-Hua; Douglas, Jeffrey A.

    2013-01-01

    The item response times (RTs) collected from computerized testing represent an underutilized type of information about items and examinees. In addition to knowing the examinees' responses to each item, we can investigate the amount of time examinees spend on each item. Current models for RTs mainly focus on parametric models, which have the…

  9. The Design and Evaluation of a Computerized Adaptive Test on Mobile Devices

    ERIC Educational Resources Information Center

    Triantafillou, Evangelos; Georgiadou, Elissavet; Economides, Anastasios A.

    2008-01-01

    The use of computerized adaptive testing (CAT) has expanded rapidly over recent years mainly due to the advances in communication and information technology. Availability of advanced mobile technologies provides several benefits to e-learning by creating an additional channel of access with mobile devices such as PDAs and mobile phones. This paper…

  10. Item Pool Design for an Operational Variable-Length Computerized Adaptive Test

    ERIC Educational Resources Information Center

    He, Wei; Reckase, Mark D.

    2014-01-01

    For computerized adaptive tests (CATs) to work well, they must have an item pool with sufficient numbers of good quality items. Many researchers have pointed out that, in developing item pools for CATs, not only is the item pool size important but also the distribution of item parameters and practical considerations such as content distribution…

  11. A Battery Certification Testbed for Small Satellite Missions

    NASA Technical Reports Server (NTRS)

    Cameron, Zachary; Kulkarni, Chetan S.; Luna, Ali Guarneros; Goebel, Kai; Poll, Scott

    2015-01-01

    A battery pack consisting of standard cylindrical 18650 lithium-ion cells has been chosen for small satellite missions based on previous flight heritage and compliance with NASA battery safety requirements. However, for batteries that transit through the International Space Station (ISS), additional certification tests are required for individual cells as well as the battery packs. In this manuscript, we discuss the development of generalized testbeds for testing and certifying different types of batteries critical to small satellite missions. Test procedures developed and executed for this certification effort include: a detailed physical inspection before and after experiments; electrical cycling characterization at the cell and pack levels; battery-pack overcharge, over-discharge, external short testing; battery-pack vacuum leak and vibration testing. The overall goals of these certification procedures are to conform to requirements set forth by the agency and identify unique safety hazards. The testbeds, procedures, and experimental results are discussed for batteries chosen for small satellite missions to be launched from the ISS.

  12. Optimization of batteries for plug-in hybrid electric vehicles

    NASA Astrophysics Data System (ADS)

    English, Jeffrey Robb

    This thesis presents a method to quickly determine the optimal battery for an electric vehicle given a set of vehicle characteristics and desired performance metrics. The model is based on four independent design variables: cell count, cell capacity, state-of-charge window, and battery chemistry. Performance is measured in seven categories: cost, all-electric range, maximum speed, acceleration, battery lifetime, lifetime greenhouse gas emissions, and charging time. The performance of each battery is weighted according to a user-defined objective function to determine its overall fitness. The model is informed by a series of battery tests performed on scaled-down battery samples. Seven battery chemistries were tested for capacity at different discharge rates, maximum output power at different charge levels, and performance in a real-world automotive duty cycle. The results of these tests enable a prediction of the performance of the battery in an automobile. Testing was performed at both room temperature and low temperature to investigate the effects of battery temperature on operation. The testing highlighted differences in behavior between lithium, nickel, and lead based batteries. Battery performance decreased with temperature across all samples with the largest effect on nickel-based chemistries. Output power also decreased with lead acid batteries being the least affected by temperature. Lithium-ion batteries were found to be highly efficient (>95%) under a vehicular duty cycle; nickel and lead batteries have greater losses. Low temperatures hindered battery performance and resulted in accelerated failure in several samples. Lead acid, lead tin, and lithium nickel alloy batteries were unable to complete the low temperature testing regime without losing significant capacity and power capability. This is a concern for their applicability in electric vehicles intended for cold climates which have to maintain battery temperature during long periods of inactivity. Three sample optimizations were performed: a compact car, a, truck, and a sports car. The compact car benefits from increased battery capacity despite the associated higher cost. The truck returned the smallest possible battery of each chemistry, indicating that electrification is not advisable. The sports car optimization resulted in the largest possible battery, indicating large performance from increased electrification. These results mirror the current state of the electric vehicle market.

  13. Satellite battery testing status

    NASA Astrophysics Data System (ADS)

    Haag, R.; Hall, S.

    1986-09-01

    Because of the large numbers of satellite cells currently being tested and anticipated at the Naval Weapons Support Center (NAVWPNSUPPCEN) Crane, Indiana, satellite cell testing is being integrated into the Battery Test Automation Project (BTAP). The BTAP, designed to meet the growing needs for battery testing at the NAVWPNSUPPCEN Crane, will consist of several Automated Test Stations (ATSs) which monitor batteries under test. Each ATS will interface with an Automation Network Controller (ANC) which will collect test data for reduction.

  14. Satellite battery testing status

    NASA Technical Reports Server (NTRS)

    Haag, R.; Hall, S.

    1986-01-01

    Because of the large numbers of satellite cells currently being tested and anticipated at the Naval Weapons Support Center (NAVWPNSUPPCEN) Crane, Indiana, satellite cell testing is being integrated into the Battery Test Automation Project (BTAP). The BTAP, designed to meet the growing needs for battery testing at the NAVWPNSUPPCEN Crane, will consist of several Automated Test Stations (ATSs) which monitor batteries under test. Each ATS will interface with an Automation Network Controller (ANC) which will collect test data for reduction.

  15. Effects of Electric Vehicle Fast Charging on Battery Life and Vehicle Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthew Shirk; Jeffrey Wishart

    2015-04-01

    As part of the U.S. Department of Energy’s Advanced Vehicle Testing Activity, four new 2012 Nissan Leaf battery electric vehicles were instrumented with data loggers and operated over a fixed on-road test cycle. Each vehicle was operated over the test route, and charged twice daily. Two vehicles were charged exclusively by AC level 2 EVSE, while two were exclusively DC fast charged with a 50 kW charger. The vehicles were performance tested on a closed test track when new, and after accumulation of 50,000 miles. The traction battery packs were removed and laboratory tested when the vehicles were new, andmore » at 10,000-mile intervals. Battery tests include constant-current discharge capacity, electric vehicle pulse power characterization test, and low peak power tests. The on-road testing was carried out through 70,000 miles, at which point the final battery tests were performed. The data collected over 70,000 miles of driving, charging, and rest are analyzed, including the resulting thermal conditions and power and cycle demands placed upon the battery. Battery performance metrics including capacity, internal resistance, and power capability obtained from laboratory testing throughout the test program are analyzed. Results are compared within and between the two groups of vehicles. Specifically, the impacts on battery performance, as measured by laboratory testing, are explored as they relate to battery usage and variations in conditions encountered, with a primary focus on effects due to the differences between AC level 2 and DC fast charging. The contrast between battery performance degradation and the effect on vehicle performance is also explored.« less

  16. Transport Properties of LiTFSI-Acetamide Room Temperature Molten Salt Electrolytes Applied in an Li-Ion Battery

    NASA Astrophysics Data System (ADS)

    Yang, Chao-Chen; Hsu, Hsin-Yi; Hsu, Chen-Ruei

    2007-11-01

    In the present work some transport properties of the binary room temperature molten salt (RTMS) lithium bis(trifluoromethane sulfone)imide (LiTFSI)-acetamide [LiN(SO2CF3)2-CH3CONH2], applied in an Li-ion battery, have been investigated. The phase diagram was determined by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The result reveals that the binary RTMS has an eutectic point at 201 K and the 30 mol% LiTFSI composition. The electric conductivity was measured using a direct current computerized method. The result shows that the conductivities of the melts increase with increasing temperature and acetamide content. The densities of all melts decrease with increasing temperature and acetamide content. The equivalent conductivities were fitted by the Arrhenius equation, where the activation energies were 18.15, 18.52, 20.35, 25.08 kJ/mol for 10, 20, 30, 40 mol% LiTFSI, respectively. Besides the relationships between conductivity, density composition and temperature, of the ion interaction is discussed.

  17. Mariner Mars 1971 battery design, test, and flight performance

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1973-01-01

    The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

  18. Testing and development of electric vehicle batteries for EPRI Electric Transportation Program

    NASA Astrophysics Data System (ADS)

    1985-11-01

    Argonne National Laboratory conducted an electric-vehicle battery testing and development program for the Electric Power Research Institute. As part of this program, eighteen battery modules previously developed by Johnson Controls, Inc. were tested. This type of battery (EV-2300 - an improved state-of-the-art lead-acid battery) was designed specifically for improved performance, range, and life in electric vehicles. In order to obtain necessary performance data, the batteries were tested under various duty cycles typical of normal service. This program, supported by the Electric Power Research Institute, consisted of three tasks: determination of the effect of cycle life vs peak power and rest period, determination of the impact of charge method on cycle life, and evaluation of the EV-2300 battery system. Two supporting studies were also carried out: one on thermal management of electric-vehicle batteries and one on enhanced utilization of active material in lead-acid batteries.

  19. A portable battery for objective, non-obstrusive measures of human performances

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.

    1984-01-01

    The need for a standardized battery of human performance tests to measure the effects of various treatments is pointed out. Progress in such a program is reported. Three batteries are available which differ in length and the number of tests in the battery. All tests are implemented on a portable, lap held, briefcase size microprocessor. Performances measured include: information processing, memory, visual perception, reasoning, and motor skills, programs to determine norms, reliabilities, stabilities, factor structure of tests, comparisons with marker tests, apparatus suitability. Rationale for the battery is provided.

  20. Project Among African-Americans to Explore Risks for Schizophrenia (PAARTNERS): Evidence for Impairment and Heritability of Neurocognitive Functioning in Families of Schizophrenia Patients

    PubMed Central

    Calkins, Monica E.; Tepper, Ping; Gur, Ruben C.; Ragland, J. Daniel; Klei, Lambertus; Wiener, Howard W.; Richard, Jan; Savage, Robert M.; Allen, Trina B.; O'Jile, Judith; Devlin, Bernie; Kwentus, Joseph; Aliyu, Muktar H.; Bradford, L. DiAnne; Edwards, Neil; Lyons, Paul D.; Nimgaonkar, Vishwajit L.; Santos, Alberto B.; Go, Rodney C.P.; Gur, Raquel E.

    2015-01-01

    Objective Neurocognitive impairments in schizophrenia are well replicated and widely regarded as candidate endophenotypes that may facilitate understanding of schizophrenia genetics and pathophysiology. The Project Among African-Americans to Explore Risks for Schizophrenia (PAARTNERS) aims to identify genes underlying liability to schizophrenia. The unprecedented size of its study group (N=1,872), made possible through use of a computerized neurocognitive battery, can help further investigation of the genetics of neurocognition. The current analysis evaluated two characteristics not fully addressed in prior research: 1) heritability of neurocognition in African American families and 2) relationship between neurocognition and psychopathology in families of African American probands with schizophrenia or schizoaffective disorder. Method Across eight data collection sites, patients with schizophrenia or schizoaffective disorder (N=610), their biological relatives (N=928), and community comparison subjects (N=334) completed a standardized diagnostic evaluation and the computerized neurocognitive battery. Performance accuracy and response time (speed) were measured separately for 10 neurocognitive domains. Results The patients with schizophrenia or schizoaffective disorder exhibited less accuracy and speed in most neurocognitive domains than their relatives both with and without other psychiatric disorders, who in turn were more impaired than comparison subjects in most domains. Estimated trait heritability after inclusion of the mean effect of diagnostic status, age, and sex revealed significant heritabilities for most neurocognitive domains, with the highest for accuracy of abstraction/ flexibility, verbal memory, face memory, spatial processing, and emotion processing and for speed of attention. Conclusions Neurocognitive functions in African American families are heritable and associated with schizophrenia. They show potential for gene-mapping studies. PMID:20194479

  1. Effects of Calibration Sample Size and Item Bank Size on Ability Estimation in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Sahin, Alper; Weiss, David J.

    2015-01-01

    This study aimed to investigate the effects of calibration sample size and item bank size on examinee ability estimation in computerized adaptive testing (CAT). For this purpose, a 500-item bank pre-calibrated using the three-parameter logistic model with 10,000 examinees was simulated. Calibration samples of varying sizes (150, 250, 350, 500,…

  2. Construct Validity and Measurement Invariance of Computerized Adaptive Testing: Application to Measures of Academic Progress (MAP) Using Confirmatory Factor Analysis

    ERIC Educational Resources Information Center

    Wang, Shudong; McCall, Marty; Jiao, Hong; Harris, Gregg

    2012-01-01

    The purposes of this study are twofold. First, to investigate the construct or factorial structure of a set of Reading and Mathematics computerized adaptive tests (CAT), "Measures of Academic Progress" (MAP), given in different states at different grades and academic terms. The second purpose is to investigate the invariance of test…

  3. An Item Response Theory-Based, Computerized Adaptive Testing Version of the MacArthur-Bates Communicative Development Inventory: Words & Sentences (CDI:WS)

    ERIC Educational Resources Information Center

    Makransky, Guido; Dale, Philip S.; Havmose, Philip; Bleses, Dorthe

    2016-01-01

    Purpose: This study investigated the feasibility and potential validity of an item response theory (IRT)-based computerized adaptive testing (CAT) version of the MacArthur-Bates Communicative Development Inventory: Words & Sentences (CDI:WS; Fenson et al., 2007) vocabulary checklist, with the objective of reducing length while maintaining…

  4. Computerized Classification Testing under the One-Parameter Logistic Response Model with Ability-Based Guessing

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Huang, Sheng-Yun

    2011-01-01

    The one-parameter logistic model with ability-based guessing (1PL-AG) has been recently developed to account for effect of ability on guessing behavior in multiple-choice items. In this study, the authors developed algorithms for computerized classification testing under the 1PL-AG and conducted a series of simulations to evaluate their…

  5. Placement Decisions for First-Time-in-College Students Using the Computerized Placement Test. Information Capsule.

    ERIC Educational Resources Information Center

    Bashford, Joanne

    This information capsule explores the effectiveness of score ranges on the Computerized Placement Test (CPT), used to assess the skills of entry-level students at Miami-Dade Community College and place first-time-in-college students in classes. Data are provided for students entering in Fall terms 1996 and 1997 showing the number of students…

  6. A Method for the Comparison of Item Selection Rules in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Barrada, Juan Ramon; Olea, Julio; Ponsoda, Vicente; Abad, Francisco Jose

    2010-01-01

    In a typical study comparing the relative efficiency of two item selection rules in computerized adaptive testing, the common result is that they simultaneously differ in accuracy and security, making it difficult to reach a conclusion on which is the more appropriate rule. This study proposes a strategy to conduct a global comparison of two or…

  7. New Battery Testing Facility Could Boost Future of Electric Vehicles

    Science.gov Websites

    industry. The Battery Thermal Test Facility at the U.S. Department of Energy's (DOE) National Renewable , ambient heat sources that could effect thermal readings from the battery. The cycler can both charge and draw current from a battery, allowing for thermal testing of any voltage. It can also be used to test

  8. The poppy seed test for colovesical fistula: big bang, little bucks!

    PubMed

    Kwon, Eric O; Armenakas, Noel A; Scharf, Stephen C; Panagopoulos, Georgia; Fracchia, John A

    2008-04-01

    Diagnosis of a colovesical fistula is often challenging, and usually involves numerous invasive and expensive tests and procedures. The poppy seed test stands out as an exception to this rule. We evaluated the accuracy and cost-effectiveness of various established diagnostic tests used to evaluate a suspected colovesical fistula. We identified 20 prospectively entered patients with surgically confirmed colovesical fistulas between 2000 and 2006. Each patient was evaluated preoperatively with a (51)chromium nuclear study, computerized tomography of the abdomen and pelvis with oral and intravenous contrast medium, and the poppy seed test. Costs were calculated using institutional charges, 2006 Medicare limiting approved charges and the market price, respectively. The z test was used to compare the proportion of patients who tested positive for a fistula with each of these modalities. The chromium study was positive in 16 of 20 patients (80%) at a cost of $490.83 per study. Computerized tomography was positive in 14 of 20 patients (70%) at a cost of $652.92 per study. The poppy seed test was positive in 20 of 20 patients (100%) at a cost of $5.37 per study. The difference in the proportion of patients who tested positive for a fistula on computerized tomography and the poppy seed test was statistically significant (p = 0.03). There was no difference between the chromium group and the computerized tomography or poppy seed group (p = 0.72 and 0.12, respectively). The poppy seed test is an accurate, convenient and inexpensive diagnostic test. It is an ideal initial consideration for evaluating a suspected colovesical fistula.

  9. Hubble Space Telescope Battery Capacity Update

    NASA Technical Reports Server (NTRS)

    Hollandsworth, Roger; Armantrout, Jon; Rao, Gopalakrishna M.

    2007-01-01

    Orbital battery performance for the Hubble Space Telescope is discussed and battery life is predicted which supports decision to replace orbital batteries by 2009-2010 timeframe. Ground characterization testing of cells from the replacement battery build is discussed, with comparison of data from battery capacity characterization with cell studies of Cycle Life and 60% Stress Test at the Naval Weapons Surface Center (NWSC)-Crane, and cell Cycle Life testing at the Marshal Space Flight Center (MSFC). The contents of this presentation includes an update to the performance of the on-orbit batteries, as well as a discussion of the HST Service Mission 4 (SM4) batteries manufactured in 1996 and activated in 2000, and a second set of SM4 backup replacement batteries which began manufacture Jan 11, 2007, with delivery scheduled for July 2008.

  10. Zinc-chloride battery technology - Status 1983

    NASA Astrophysics Data System (ADS)

    Rowan, J. W.; Carr, P.; Warde, C. J.; Henriksen, G. L.

    Zinc-chloride batteries are presently under development at Energy Development Associates (EDA) for load-leveling, electric-vehicle, and specialty applications. A 500-kWh battery system has been built at Detroit Edison's Charlotte substation near downtown Detroit. Following shakedown testing, this system will be installed at the Battery Energy Storage Test (BEST) Facility in Hillsborough, New Jersey, in July 1983. Data is presented also for a prototype 50-kWh battery which has successfully operated through 150 cycles. EDA has built and tested three 4-passenger automobiles. The maximum range achieved on a single charge was 200 miles at 40 mph. Recently, the electric-vehicle battery program at EDA has focused on commercial vehicles. Two vans, each powered with a 45-kWh zinc-chloride battery, have been built and track tested. These vehicles, which carry a payload of 1,000 pounds, have a top speed of 55 mph and an operational range in excess of 80 miles. In the specialty battery area, two 6-kWh 12-V reserve batteries have been built and tested. This type of battery offers the prospect of long shelf life and an energy density in excess of 100 Wh/lb.

  11. [Normalisation and validation of the Brief Neuropsychological Battery as the reference neuropsychological test in multiple sclerosis].

    PubMed

    Duque, P; Ibanez, J; Del Barco, A; Sepulcre, J; de Ramon, E; Fernandez-Fernandez, O

    2012-03-01

    INTRODUCTION. The current batteries such as the Brief Repeatable Battery of Neuropsychological Tests (BRB-N) for evaluating cognitive decline in patients with multiple sclerosis are complex and time-consuming. AIM. To obtain normative values and validate a new battery. SUBJECTS AND METHODS. Four neuropsychological tests were finally included (episodic memory, the Symbol-Digit Modalities Test, a category fluency test, and the Paced Auditory Serial Addition Test). Normative values (overall and by age group) were derived by administering the battery to healthy subjects (5th percentile was the limit of normal). External validity was explored by comparison with the BRB-N. The new battery was also administered to a subsample after 4 weeks to assess reproducibility. RESULTS. To provide normative data, 1036 healthy subjects were recruited. The mean completion time was 18.5 ± 5.2 minutes. For the 229 subjects who were administered the new battery and the BRB-N, no statistically significant differences were found except for mean completion time (19 ± 4 vs 25 ± 5 minutes). In the reproducibility study, there were no significant differences except in the memory tests. CONCLUSION. The scores on the new battery and the BRB-N were strongly correlated although the shorter completion time and ease of administration could make the new battery preferable in clinical practice.

  12. Relationship of Attention Deficit Hyperactivity Disorder and Postconcussion Recovery in Youth Athletes.

    PubMed

    Mautner, Kenneth; Sussman, Walter I; Axtman, Matthew; Al-Farsi, Yahya; Al-Adawi, Samir

    2015-07-01

    To investigate whether attention deficit hyperactivity disorder (ADHD) influences postconcussion recovery, as measured by computerized neurocognitive testing. This is a retrospective case control study. Computer laboratories across 10 high schools in the greater Atlanta, Georgia area. Immediate postconcussion assessment and cognitive testing (ImPACT) scores of 70 athletes with a self-reported diagnosis of ADHD and who sustained a sport-related concussion were compared with a randomly selected age-matched control group. Immediate postconcussion assessment and cognitive testing scores over a 5-year interval were reviewed for inclusion. Postconcussion recovery was defined as a return to equivalent baseline neurocognitive score on the ImPACT battery, and a concussion symptom score of ≤7. Athletes with ADHD had on average a longer time to recovery when compared with the control group (16.5 days compared with 13.5 days), although not statistically significant. The number of previous concussions did not have any effect on the rate of recovery in the ADHD or the control group. In addition, baseline neurocognitive testing did not statistically differ between the 2 groups, except in verbal memory. Although not statistically significant, youth athletes with ADHD took on average 3 days longer to return to baseline neurocognitive testing compared with a control group without ADHD. Youth athletes with ADHD may have a marginally prolonged recovery as indexed by neurocognitive testing and should be considered when prognosticating time to recovery in this subset of student athletes.

  13. Users manual for the Automated Performance Test System (APTS)

    NASA Technical Reports Server (NTRS)

    Lane, N. E.; Kennedy, R. S.

    1990-01-01

    The characteristics of and the user information for the Essex Automated Performance Test System (APTS) computer-based portable performance assessment battery are given. The battery was developed to provide a menu of performance test tapping the widest possible variety of human cognitive and motor functions, implemented on a portable computer system suitable for use in both laboratory and field settings for studying the effects of toxic agents and other stressors. The manual gives guidance in selecting, administering and scoring tests from the battery, and reviews the data and studies underlying the development of the battery. Its main emphasis is on the users of the battery - the scientists, researchers and technicians who wish to examine changes in human performance across time or as a function of changes in the conditions under which test data are obtained. First the how to information needed to make decisions about where and how to use the battery is given, followed by the research background supporting the battery development. Further, the development history of the battery focuses largely on the logical framework within which tests were evaluated.

  14. Impairment of Concept Formation Ability in Children with ADHD: Comparisons between Lower Grades and Higher Grades

    PubMed Central

    Hong, Hye Jeong; Kim, Jin Sung; Seo, Wan Seok; Koo, Bon Hoon; Bai, Dai Seg; Jeong, Jin Young

    2010-01-01

    Objective We investigated executive functions (EFs), as evaluated by the Wisconsin Card Sorting Test (WCST), and other EF between lower grades (LG) and higher grades (HG) in elementary-school-age attention deficit hyperactivity disorder (ADHD) children. Methods We classified a sample of 112 ADHD children into 4 groups (composed of 28 each) based on age (LG vs. HG) and WCST performance [lower vs. higher performance on WCST, defined by the number of completed categories (CC)] Participants in each group were matched according to age, gender, ADHD subtype, and intelligence. We used the Wechsler intelligence Scale for Children 3rd edition to test intelligence and the Computerized Neurocognitive Function Test-IV, which included the WCST, to test EF. Results Comparisons of EFs scores in LG ADHD children showed statistically significant differences in performing digit spans backward, some verbal learning scores, including all memory scores, and Stroop test scores. However, comparisons of EF scores in HG ADHD children did not show any statistically significant differences. Correlation analyses of the CC and EF variables and stepwise multiple regression analysis in LG ADHD children showed a combination of the backward form of the Digit span test and Visual span test in lower-performance ADHD participants significantly predicted the number of CC (R2=0.273, p<0.001). Conclusion This study suggests that the design of any battery of neuropsychological tests for measuring EF in ADHD children should first consider age before interpreting developmental variations and neuropsychological test results. Researchers should consider the dynamics of relationships within EF, as measured by neuropsychological tests. PMID:20927306

  15. 2007 Nissan Altima-7982 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Grey; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Nissan Altima hybrid electric vehicle (Vin Number 1N4CL21E27C177982). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporationmore » conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.« less

  16. Computer-based, personalized cognitive training versus classical computer games: a randomized double-blind prospective trial of cognitive stimulation.

    PubMed

    Peretz, Chava; Korczyn, Amos D; Shatil, Evelyn; Aharonson, Vered; Birnboim, Smadar; Giladi, Nir

    2011-01-01

    Many studies have suggested that cognitive training can result in cognitive gains in healthy older adults. We investigated whether personalized computerized cognitive training provides greater benefits than those obtained by playing conventional computer games. This was a randomized double-blind interventional study. Self-referred healthy older adults (n = 155, 68 ± 7 years old) were assigned to either a personalized, computerized cognitive training or to a computer games group. Cognitive performance was assessed at baseline and after 3 months by a neuropsychological assessment battery. Differences in cognitive performance scores between and within groups were evaluated using mixed effects models in 2 approaches: adherence only (AO; n = 121) and intention to treat (ITT; n = 155). Both groups improved in cognitive performance. The improvement in the personalized cognitive training group was significant (p < 0.03, AO and ITT approaches) in all 8 cognitive domains. However, in the computer games group it was significant (p < 0.05) in only 4 (AO) or 6 domains (ITT). In the AO analysis, personalized cognitive training was significantly more effective than playing games in improving visuospatial working memory (p = 0.0001), visuospatial learning (p = 0.0012) and focused attention (p = 0.0019). Personalized, computerized cognitive training appears to be more effective than computer games in improving cognitive performance in healthy older adults. Further studies are needed to evaluate the ecological validity of these findings. Copyright © 2011 S. Karger AG, Basel.

  17. Life prediction and reliability assessment of lithium secondary batteries

    NASA Astrophysics Data System (ADS)

    Eom, Seung-Wook; Kim, Min-Kyu; Kim, Ick-Jun; Moon, Seong-In; Sun, Yang-Kook; Kim, Hyun-Soo

    Reliability assessment of lithium secondary batteries was mainly considered. Shape parameter (β) and scale parameter (η) were calculated from experimental data based on cycle life test. We also examined safety characteristics of lithium secondary batteries. As proposed by IEC 62133 (2002), we had performed all of the safety/abuse tests such as 'mechanical abuse tests', 'environmental abuse tests', 'electrical abuse tests'. This paper describes the cycle life of lithium secondary batteries, FMEA (failure modes and effects analysis) and the safety/abuse tests we had performed.

  18. ECHO: A Computer Based Test for the Measurement of Individualistic, Cooperative, Defensive, and Aggressive Models of Behavior. Occasional Paper No. 30.

    ERIC Educational Resources Information Center

    Krus, David J.; And Others

    This paper describes a test which attempts to measure a group of personality traits by analyzing the actual behavior of the participant in a computer-simulated game. ECHO evolved from an extension and computerization of Horstein and Deutsch's allocation game. The computerized version of ECHO requires subjects to make decisions about the allocation…

  19. On the Reliability and Validity of a Numerical Reasoning Speed Dimension Derived from Response Times Collected in Computerized Testing

    ERIC Educational Resources Information Center

    Davison, Mark L.; Semmes, Robert; Huang, Lan; Close, Catherine N.

    2012-01-01

    Data from 181 college students were used to assess whether math reasoning item response times in computerized testing can provide valid and reliable measures of a speed dimension. The alternate forms reliability of the speed dimension was .85. A two-dimensional structural equation model suggests that the speed dimension is related to the accuracy…

  20. Development of a Computerized Adaptive Testing for Diagnosing the Cognitive Process of Grade 7 Students in Learning Algebra, Using Multidimensional Item Response Theory

    ERIC Educational Resources Information Center

    Senarat, Somprasong; Tayraukham, Sombat; Piyapimonsit, Chatsiri; Tongkhambanjong, Sakesan

    2013-01-01

    The purpose of this research is to develop a multidimensional computerized adaptive test for diagnosing the cognitive process of grade 7 students in learning algebra by applying multidimensional item response theory. The research is divided into 4 steps: 1) the development of item bank of algebra, 2) the development of the multidimensional…

  1. Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB). Part 1: Design and specification of the battery

    NASA Astrophysics Data System (ADS)

    Englund, C. E.; Reeves, D. L.; Shingledecker, C. A.; Thorne, D. R.; Wilson, K. P.

    1987-02-01

    The Unified Tri-Service Cognitive Performance Assessment Battery (UTC-PAB) represents the primary metric for a Level 2 evaluation of cognitive performance in the JWGD3 MILPERF chemical defense biomedical drug screening program. Emphasis for UTC-PAB development has been on the standardization of test batteries across participating laboratories with respect to content, computer-based administration, test scoring, and data formatting. This effort has produced a 25-test UTC-PAB that represents the consolidation and unification of independent developments by the Tri-service membership. Test selection was based on established test validity and relevance of military performance. Sensitivity to effects of hostile environments and sustained operations were also considerations involved in test selection. Information processing, decision making, perception, and mental workload capacity are among the processes and abilities addressed in the battery. The UTC-PAB represents a dynamic approach to battery development. The nature of the biomedical drugs screened and information from performance centered task analyses will direct the form of future versions of the battery.

  2. Charge Efficiency Tests of Lead/Acid Batteries

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J.

    1984-01-01

    Current, voltage, and gas evolution measured during charge/discharge cycles. Series of standarized tests for evaluating charging efficiency of lead/acid storage batteries described in report. Purpose of tests to provide information for design of battery charger that allows maximum recharge efficiency for electric-vehicle batteries consistent with other operating parameters, such as range, water loss, and cycle life.

  3. The Danish test battery for auditory processing disorder evaluated with patient and control data.

    PubMed

    Raben Pedersen, Ellen

    2018-06-10

    This study evaluates the Danish test battery for auditory processing disorder (APD). The battery consists of four behavioural tests, two speech and two non-speech stimuli tests. The evaluation includes determination of: (1) new cut-off values (pass-fail criteria), (2) the sensitivity and the specificity of the entire test battery and (3) the failure rate of different test combinations. For each test in the battery, cut-off values were determined using the weighted Youden index. Applying the newly derived cut-off values, the distribution of failing specific test combinations was determined. A group of 112 children diagnosed with APD (57 boys, 55 girls, aged 6-16 years) and a control group containing 158 children without auditory problems (75 boys, 83 girls, aged 6-16 years). Cut-off values for different weights of the sensitivity and the specificity have been determined. Using the criterion that at least two tests have to be failed for APD to be suspected, the sensitivity and the specificity of the entire test battery were 95.3% and 91.6%, respectively. Some test combinations were found to have higher failure rates than others. Due to the high sensitivity and specificity the test battery has good predictive value in APD assessment.

  4. Decision Making Processes and Outcomes

    PubMed Central

    Hicks Patrick, Julie; Steele, Jenessa C.; Spencer, S. Melinda

    2013-01-01

    The primary aim of this study was to examine the contributions of individual characteristics and strategic processing to the prediction of decision quality. Data were provided by 176 adults, ages 18 to 93 years, who completed computerized decision-making vignettes and a battery of demographic and cognitive measures. We examined the relations among age, domain-specific experience, working memory, and three measures of strategic information search to the prediction of solution quality using a 4-step hierarchical linear regression analysis. Working memory and two measures of strategic processing uniquely contributed to the variance explained. Results are discussed in terms of potential advances to both theory and intervention efforts. PMID:24282638

  5. Reserve Li/SOC12 Battery Safety Testing

    NASA Technical Reports Server (NTRS)

    Dils, C. T.; Garoutte, K. F.

    1984-01-01

    A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

  6. Crane Cell Testing Support of Nasa/goddard Space Flight Center: an Update

    NASA Technical Reports Server (NTRS)

    Strawn, Mike; David, Jerry; Rao, Gopalakrishna M.

    2001-01-01

    The objective of this paper is to verify the quality and reliability of aerospace battery cells and batteries for NASA flight programs, disseminate the data - to develop a plan for in-orbit battery management - to design a cell/battery for future NASA spacecraft and establish a cell test data base for rechargeable cell/batteries.

  7. [ALPHA-fitness test battery: health-related field-based fitness tests assessment in children and adolescents].

    PubMed

    Ruiz, J R; España Romero, V; Castro Piñero, J; Artero, E G; Ortega, F B; Cuenca García, M; Jiménez Pavón, D; Chillón, P; Girela Rejón, Ma J; Mora, J; Gutiérrez, A; Suni, J; Sjöstrom, M; Castillo, M J

    2011-01-01

    Hereby we summarize the work developed by the ALPHA (Assessing Levels of Physical Activity) Study and describe the tests included in the ALPHA health-related fitness test battery for children and adolescents. The evidence-based ALPHA-Fitness test battery include the following tests: 1) the 20 m shuttle run test to assess cardiorespiratory fitness; 2) the handgrip strength and 3) standing broad jump to assess musculoskeletal fitness, and 4) body mass index, 5) waist circumference; and 6) skinfold thickness (triceps and subscapular) to assess body composition. Furthermore, we include two versions: 1) the high priority ALPHA health-related fitness test battery, which comprises all the evidence-based fitness tests except the measurement of the skinfold thickness; and 2) the extended ALPHA health-related fitness tests battery for children and adolescents, which includes all the evidence-based fitness tests plus the 4 x 10 m shuttle run test to assess motor fitness.

  8. A menu of self-administered microcomputer-based neurotoxicology tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Kuntz, Lois-Ann; Baltzley, Dennis R.

    1988-01-01

    This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

  9. Glossary of testing terminology for rechargeable batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, P.C.

    1988-10-01

    The Battery Test Working Task Force was formed in 1983 for the purpose of coordinating the evaluation of development rechargeable batteries by DOE-funded labs. The Task Force developed this glossary of testing terminology to improve the accuracy of communication and to permit meaningful comparisons of test results. It consists of a section of technical terms and a separate section of programmatic phrases and acronyms. The glossary emphasizes terms related to electric vehicle batteries due to the significant development and testing activities in this area. 8 refs.

  10. The 1988 Goddard Space Flight Center Battery Workshop

    NASA Technical Reports Server (NTRS)

    Yi, Thomas Y. (Editor)

    1993-01-01

    This document contains the proceedings of the 21st annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 1-3, 1988. The Workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included battery testing methodologies and criteria, life testing of nickel-cadmium cells, testing and operation of nickel-hydrogen batteries in low earth orbit, and nickel-hydrogen technology issues and concerns.

  11. Nonleaking battery terminals

    NASA Technical Reports Server (NTRS)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45 percent KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide (PPO) plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a potassium hydroxide (KOH) electrolyte in a plastic case are discussed.

  12. Nonleaking battery terminals.

    NASA Technical Reports Server (NTRS)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

  13. Equipment for testing automotive lead/acid batteries under SAE J240a conditions

    NASA Astrophysics Data System (ADS)

    Hamilton, J. A.; Rand, D. A. J.

    Battery cycling equipment has been designed and constructed to test lead/acid batteries according to the American Society of Automotive Engineers' (SAE) J240a Standard. This life test simulates automotive service where the battery operates in a voltage-regulated charging system. The CSIRO design uses a master/slave concept to reduce both construction time and cost.

  14. Open stack thermal battery tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Kevin N.; Roberts, Christine C.; Grillet, Anne M.

    We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transversemore » to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.« less

  15. Drug-resistant MS spasticity treatment with Sativex(®) add-on and driving ability.

    PubMed

    Freidel, M; Tiel-Wilck, K; Schreiber, H; Prechtl, A; Essner, U; Lang, M

    2015-01-01

    The aim of the present observational study was to determine the effects of a delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) oromucosal spray (Sativex(®) spray), brand name Sativex(®), indicated for drug-resistant MS spasticity, on the driving ability of treated MS patients. The study was conducted over a period of 4-6 weeks. Thirty-three MS patients with moderate to severe treatment-resistant spasticity and planned to begin add-on treatment with Sativex(®) were enrolled at three specialized MS centres in Germany. A set of five driving test procedures from a validated computerized test battery was used to evaluate the driving ability of eligible patients. Tests were performed by patients at baseline and repeated after 4-6 weeks of treatment with Sativex(®) oromucosal spray. According to German normative data, the test thresholds achieved by the general population served as a reference to allow for a fitness/unfitness to drive classification. Patients showed comparable driving test results at baseline and at final visits. Only two patients changed classification shifting from 'unfit' to drive to 'fit' and vice versa. The mean severity of spasticity, as self-reported by the patients, improved with statistical significance. Sativex(®) was generally well tolerated. Treatment of MS patients with Sativex(®) does not negatively impact on driving ability and may improve moderate to severe treatment-resistant MS spasticity. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Invalid performance and the ImPACT in national collegiate athletic association division I football players.

    PubMed

    Szabo, Ashley J; Alosco, Michael L; Fedor, Andrew; Gunstad, John

    2013-01-01

    Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a computerized cognitive test battery commonly used for concussion evaluation. An important aspect of these procedures is baseline testing, but researchers have suggested that many users do not use validity indices to ensure adequate effort during testing. No one has examined the prevalence of invalid performance for college football players. To examine the prevalence of invalid scores on ImPACT testing. Cross-sectional study. National Collegiate Athletic Association Division I university. A total of 159 athletes (age = 20.3 ± 1.41 years; range = 17.8-23.7 years) from a Division I collegiate football team participated. An informational intervention regarding the importance of concussion testing to promote safety was administered before testing for the most recent season. We examined preseason ImPACT testing data across a 3-year period (total assessments = 269). Based on invalid and sandbagging indices denoted by the ImPACT manual, protocols were examined to indicate how many invalid indices each athlete had. A total of 27.9% (n = 75) of assessments were suggestive of invalid scores, with 4.1% (n = 11) suggesting invalid responding only, 17.5% (n = 47) indicating "sandbagging" only, and 6.3% (n = 17) showing both invalid and sandbagging responding. The informational intervention did not reduce the prevalence of invalid responding. These findings highlight the need for further information about the ImPACT validity indices and whether they truly reflect poor effort. Future work is needed to identify practices to reliably target and reduce invalid responding.

  17. The UltraBattery-A new battery design for a new beginning in hybrid electric vehicle energy storage

    NASA Astrophysics Data System (ADS)

    Cooper, A.; Furakawa, J.; Lam, L.; Kellaway, M.

    The UltraBattery, developed by CSIRO Energy Technology in Australia, is a hybrid energy storage device which combines an asymmetric super-capacitor and a lead-acid battery in single unit cells. This takes the best from both technologies without the need for extra, expensive electronic controls. The capacitor enhances the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging, thus enabling it to provide and absorb charge rapidly during vehicle acceleration and braking. The initial performance of the prototype UltraBatteries was evaluated according to the US FreedomCAR targets and was shown to meet or exceed these in terms of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist hybrid electric vehicles (HEVs). Other laboratory cycling tests showed a fourfold improvement over previous state-of-the-art lead-acid batteries under the RHOLAB test profile and better life than commercial nickel/metal hydride (NiMH) cells used in a Honda Insight when tested under the EUCAR HEV profile. As a result of this work, a set of twelve 12 V modules was built by The Furukawa Battery Co., Ltd. in Japan and were fitted into a Honda Insight instead of the NiMH battery by Provector Ltd. The battery pack was fitted with full monitoring and control capabilities and the car was tested at Millbrook Proving Ground under a General Motors road test simulation cycle for an initial target of 50 000 miles which was extended to 100 000 miles. This was completed on 15th January 2008 without any battery problems. Furthermore, the whole test was completed without the need for any conditioning or equalisation of the battery pack.

  18. Data pieces-based parameter identification for lithium-ion battery

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Zou, Yuan; Sun, Fengchun; Hu, Xiaosong; Yu, Yang; Feng, Sen

    2016-10-01

    Battery characteristics vary with temperature and aging, it is necessary to identify battery parameters periodically for electric vehicles to ensure reliable State-of-Charge (SoC) estimation, battery equalization and safe operation. Aiming for on-board applications, this paper proposes a data pieces-based parameter identification (DPPI) method to identify comprehensive battery parameters including capacity, OCV (open circuit voltage)-Ah relationship and impedance-Ah relationship simultaneously only based on battery operation data. First a vehicle field test was conducted and battery operation data was recorded, then the DPPI method is elaborated based on vehicle test data, parameters of all 97 cells of the battery package are identified and compared. To evaluate the adaptability of the proposed DPPI method, it is used to identify battery parameters of different aging levels and different temperatures based on battery aging experiment data. Then a concept of ;OCV-Ah aging database; is proposed, based on which battery capacity can be identified even though the battery was never fully charged or discharged. Finally, to further examine the effectiveness of the identified battery parameters, they are used to perform SoC estimation for the test vehicle with adaptive extended Kalman filter (AEKF). The result shows good accuracy and reliability.

  19. Nickel-cadium batteries for Apollo telescope mount

    NASA Technical Reports Server (NTRS)

    Kirsch, W. W.; Shikoh, A. E.

    1974-01-01

    The operational testing and evaluation program is presented which was conducted on 20-ampere-hour nickel-cadmium (Ni-Cd) batteries for use on the Apollo telescope mount (ATM). The test program was initiated in 1967 to determine if the batteries could meet ATM mission requirements and to determine operating characteristics and methods. The ATM system power and charging power for the Ni-Cd secondary batteries is provided by a solar array during the 58-minute daylight portion of the orbit; during the 36-minute night portion of the orbit, the Ni-Cd secondary batteries will supply ATM system power. The test results reflect battery operating characteristics and parameters relative to simulated ATM orbital test conditions. Maximum voltage, charge requirements, capacity, temperature, and cyclic characteristics are presented.

  20. A Path to an Instructional Science: Data-Generated vs. Postulated Models

    ERIC Educational Resources Information Center

    Gropper, George L.

    2016-01-01

    Psychological testing can serve as a prototype on which to base a data-generated approach to instructional design. In "testing batteries" tests are used to predict achievement. In the proposed approach batteries of prescriptions would be used to produce achievement. In creating "test batteries" tests are selected for their…

  1. Development of satellite borne nickel hydrogen battery experiment equipment for ETS-6

    NASA Astrophysics Data System (ADS)

    Kuwashima, Saburou; Kamimori, Norimitsu; Kusawake, Hiroaki; Takahashi, Kazumichi

    1992-08-01

    An overview of the support rendered for the Engineering Test Satellite-6 (ETS-6) system integration test and protoflight test by the ETS-6 borne experimental nickel hydrogen battery development part is presented. Articles in the ETS-6 specifications and procedures related to the experimental battery were prepared or supported in preparation because of the battery's special characteristics such as its automatic control dependency on the bus voltage, thermal sensitivity equivalent to that of other batteries and so forth. System tests were witnessed and the acquired data were evaluated. Charging characteristics from 0 V were verified at trickle charging rate, using a flight scale model of Nickel Hydrogen (Ni-H2) Battery (NHB) after long term storage and an engineering model of the Ni-H2 Battery Controller (NHC). Requests for approval were submitted to the related self governing bodies in accordance with the Explosives Control Law when NHB's were charged and discharged. Installation and calibration data acquisition of the inner pressure sensors for the Ni-H2 battery cells for the flight model NHB were conducted and the battery assembly was started.

  2. Evaluation program for secondary spacecraft cells: Cycle life test

    NASA Technical Reports Server (NTRS)

    Harkness, J. D.

    1979-01-01

    The service life and storage stability for several storage batteries were determined. The batteries included silver-zinc batteries, nickel-cadmium batteries, and silver-cadmium batteries. The cell performance characteristics and limitations are to be used by spacecraft power systems planners and designers. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is presented.

  3. Space Technology-5 Lithium-Ion Battery Design, Qualification and Integration and Testing

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakishna M.; Stewart, Karen; Ameen, Syed; Banfield, Peter K.

    2005-01-01

    This document is a viewgraph presentation that reviews the Lithium Ion Battery for the Space Technology-5 (ST-5) mission. Included in the document is a review of the ST-5 Mission, a review of the battery requirements, a description of the battery and the battery materials. The testing and the integration and qualification data is reviewed.

  4. An Evaluation of Computerized Tests as Predictors of Job Performance: II. Differential Validity for Global and Job Element Criteria. Final Report.

    ERIC Educational Resources Information Center

    Cory, Charles H.

    This report presents data concerning the validity of a set of experimental computerized and paper-and-pencil tests for measures of on-job performance on global and job elements. It reports on the usefulness of 30 experimental and operational variables for predicting marks on 42 job elements and on a global criterion for Electrician's Mate,…

  5. The Use of Statistical Process Control-Charts for Person-Fit Analysis on Computerized Adaptive Testing. LSAC Research Report Series.

    ERIC Educational Resources Information Center

    Meijer, Rob R.; van Krimpen-Stoop, Edith M. L. A.

    In this study a cumulative-sum (CUSUM) procedure from the theory of Statistical Process Control was modified and applied in the context of person-fit analysis in a computerized adaptive testing (CAT) environment. Six person-fit statistics were proposed using the CUSUM procedure, and three of them could be used to investigate the CAT in online test…

  6. Effects of Bright Light Therapy of Sleep, Cognition, Brain Function, and Neurochemistry in Mild Traumatic Brain Injury

    DTIC Science & Technology

    2012-01-01

    computerized stimulation paradigms for use during functional neuroimaging (i.e., MSIT). Accomplishments: • The following computer tasks were...and Stability Test. • Programming of all computerized functional MRI stimulation paradigms and assessment tasks using E-prime software was completed...Computer stimulation paradigms were tested in the scanner environment to ensure that they could be presented and seen by subjects in the scanner

  7. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  8. Development of a Valid Volleyball Skills Test Battery.

    ERIC Educational Resources Information Center

    Bartlett, Jackie; And Others

    1991-01-01

    Describes the development of the North Carolina State University Volleyball Skills Test Battery which offers accurate measurement of three volleyball skills (serve, forearm pass, and set). When physical educators tested 313 students, the battery objectively measured their abilities, providing a gamelike means of teaching, testing, grouping, and…

  9. Li-Ion Battery Studies at NASA/Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Lee, Leonine; Rao, Gopalakrishna M.

    2006-01-01

    This viewgraph presentation reviews NASA and GSFC's interest in Lithium Ion Batteries as power suupplies for space usage, the tests, and results on several commercially available batteries. Severl batteries were tested for Geosynchronous orbit, Low Earth Orbit, and Low Lunar Orbit conditions.

  10. CogState computerized memory tests in patients with brain metastases: secondary endpoint results of NRG Oncology RTOG 0933.

    PubMed

    Caine, Chip; Deshmukh, Snehal; Gondi, Vinai; Mehta, Minesh; Tomé, Wolfgang; Corn, Benjamin W; Kanner, Andrew; Rowley, Howard; Kundapur, Vijayananda; DeNittis, Albert; Greenspoon, Jeffrey Noah; Konski, Andre A; Bauman, Glenn S; Raben, Adam; Shi, Wenyin; Wendland, Merideth; Kachnic, Lisa

    2016-01-01

    Whole brain radiotherapy (WBRT) is associated with memory dysfunction. As part of NRG Oncology RTOG 0933, a phase II study of WBRT for brain metastases that conformally avoided the hippocampal stem cell compartment (HA-WBRT), memory was assessed pre- and post-HA-WBRT using both traditional and computerized memory tests. We examined whether the computerized tests yielded similar findings and might serve as possible alternatives for assessment of memory in multi-institution clinical trials. Adult patients with brain metastases received HA-WBRT to 30 Gy in ten fractions and completed Hopkins Verbal Learning Test-Revised (HVLT-R), CogState International Shopping List Test (ISLT) and One Card Learning Test (OCLT), at baseline, 2 and 4 months. Tests' completion rates were 52-53 % at 2 months and 34-42 % at 4 months. All baseline correlations between HVLT-R and CogState tests were significant (p ≤ 0.003). At baseline, both CogState tests and one component of HVLT-R differentiated those who were alive at 6 months and those who had died (p ≤ 0.01). At 4 months, mean relative decline was 7.0 % for HVLT-R Delayed Recall and 18.0 % for ISLT Delayed Recall. OCLT showed an 8.0 % increase. A reliable change index found no significant changes from baseline to 2 and 4 months for ISLT Delayed Recall (z = -0.40, p = 0.34; z = -0.68, p = 0.25) or OCLT (z = 0.15, p = 0.56; z = 0.41, p = 0.66). Study findings support the possibility that hippocampal avoidance may be associated with preservation of memory test performance, and that these computerized tests also may be useful and valid memory assessments in multi-institution adult brain tumor trials.

  11. Accelerated battery-life testing - A concept

    NASA Technical Reports Server (NTRS)

    Mccallum, J.; Thomas, R. E.

    1971-01-01

    Test program, employing empirical, statistical and physical methods, determines service life and failure probabilities of electrochemical cells and batteries, and is applicable to testing mechanical, electrical, and chemical devices. Data obtained aids long-term performance prediction of battery or cell.

  12. Cognitive remediation for adolescents with 22q11 deletion syndrome (22q11DS): a preliminary study examining effectiveness, feasibility, and fidelity of a hybrid strategy, remote and computer-based intervention.

    PubMed

    Mariano, Margaret A; Tang, Kerri; Kurtz, Matthew; Kates, Wendy R

    2015-08-01

    22q11DS is a multiple anomaly syndrome involving intellectual and behavioral deficits, and increased risk for schizophrenia. As cognitive remediation (CR) has recently been found to improve cognition in younger patients with schizophrenia, we investigated the efficacy, feasibility, and fidelity of a remote, hybrid strategy, computerized CR program in youth with 22q11DS. A longitudinal design was implemented in which 21 participants served as their own controls. Following an eight month baseline period in which no interventions were provided, cognitive coaches met with participants remotely for CR via video conferencing three times a week over a targeted 8month timeframe and facilitated their progress through the intervention, offering task-specific strategies. A subset of strategies were examined for fidelity. Outcomes were evaluated using a neurocognitive test battery at baseline, pre-treatment and post-treatment. All participants adhered to the intervention. The mean length of the treatment phase was 7.96months. A moderately high correlation (intraclass correlation coefficient, 0.73) was found for amount and type of strategies offered by coaches. Participants exhibited significant improvements (ES=.36-.55, p≤.009) in working memory, shifting attention and cognitive flexibility. All significant models were driven by improvements in pre to post-treatment scores. Based on our preliminary investigation, a remote, hybrid strategy, computerized CR program can be implemented with 22q11DS youth despite geographic location, health, and cognitive deficits. It appears effective in enhancing cognitive skills during the developmental period of adolescence, making this type of CR delivery useful for youth with 22q11DS transitioning into post-school environments. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    NASA Astrophysics Data System (ADS)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  14. SHAWNEE LIME/LIMESTONE SCRUBBING COMPUTERIZED DESIGN/COST-ESTIMATE MODEL USERS MANUAL

    EPA Science Inventory

    The manual gives a general description of the Shawnee lime/limestone scrubbing computerized design/cost-estimate model and detailed procedures for using it. It describes all inputs and outputs, along with available options. The model, based on Shawnee Test Facility scrubbing data...

  15. Special Test Methods for Batteries

    NASA Technical Reports Server (NTRS)

    Gross, S.

    1984-01-01

    Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

  16. Special test methods for batteries

    NASA Astrophysics Data System (ADS)

    Gross, S.

    1984-09-01

    Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

  17. The electrical performance of Ag Zn batteries for the Venus multi-probe mission

    NASA Technical Reports Server (NTRS)

    Palandati, C.

    1975-01-01

    An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.

  18. Mixed results in the safety performance of computerized physician order entry.

    PubMed

    Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C

    2010-04-01

    Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.

  19. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.48 Acid resistance test. (a) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  20. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.48 Acid resistance test. (a) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  1. UHM/HNEI EV test and evaluation program

    NASA Astrophysics Data System (ADS)

    1992-03-01

    The electric vehicle (EV) program of the Hawaii Natural Energy Institute (HNEI) focuses primarily on the field testing of promising EV/traction batteries. The intent is to utilize typical driving cycles to develop information that verifies or refutes what is obtained in the laboratory. Three different types of batteries were assigned by the U.S. DOE for testing in this program: Sonnenschein Dryfit 6V-160, Exide GC-5, Trojan T-145. We added the following battery to the test program: ALCO2200. The following EVs were chosen in our program: Converted Ford Escort station wagon, Converted Ford Escort two-door sedan, Converted Ford Escort two-door sedan, Converted Dodge van. Based on capacity tests, corrective action such as battery replacement, additional charging, adjusting terminal connections, etc., may be taken to maintain good performance. About 15,500 miles and 600 cycles have been accumulated on the Sonnenschein Dryfit 6V-160 battery pack. Five of its 18 modules have been changed. Based on DOE's standard, the battery has reached the end of its useful life. Nevertheless, the battery pack is still operational and its operating range is still greater than 40 miles per charge. It is too early to evaluate the life expectancy of the other three batteries. No module has been replaced in these three packs. HNEI will keep the Trojan and Exide battery packs in operation. The Alco 2200 batteries will be transferred to another vehicle.

  2. Hubble Space Telescope On-orbit NiH2 Battery Performance

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakrishna M.; Krol, Stanley J., Jr.

    2002-01-01

    This paper summarizes the Hubble Space Telescope (HST) nickel-hydrogen (NiH2) battery performance from launch to the present time. Over the life of HST vehicle configuration, charge system degradation and failures together with thermal design limitations have had a significant effect on the capacity of the HST batteries. Changes made to the charge system configuration in order to protect against power system failures and to maintain battery thermal stability resulted in undercharging of the batteries. This undercharging resulted in decreased usable battery capacity as well as battery cell voltage/capacity divergence. This cell divergence was made evident during on-orbit battery capacity measurements by a relatively shallow slope of the discharge curve following the discharge knee. Early efforts to improve the battery performance have been successful. On-orbit capacity measurement data indicates increases in the usable battery capacity of all six batteries as well as improvements in the battery cell voltage/capacity divergence. Additional measures have been implemented to improve battery performance, however, failures within the HST Power Control Unit (PCU) have prevented verification of battery status. As this PCU fault prevents the execution of on-orbit capacity testing, the HST Project has based the battery capacity on trends, which utilizes previous on-orbit battery capacity test data, for science mission and servicing mission planning. The Servicing Mission 38 (SM-3B) in March 2002 replaced the faulty PCU. Following the servicing mission, on-orbit capacity test resumed. A summary of battery performance is reviewed since launch in this paper.

  3. Initial testing of two DEMI (Driesbach Electromotive Inc. ) Model 4E zinc-air rechargeable cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.; Martin, M.E.

    1989-10-23

    The purpose of this document is to report the results of INEL laboratory testing of two DEMI 4E Aerobic Power Battery Cells (collectively designated Pack 46 in INEL records). The 4E Aerobic Power Battery is a secondary battery developed privately by Driesbach Electromotive Inc. (DEMI). The battery employs zinc as the anode and a bifunctional air cathode. This testing was performed as the first phase of a cooperative agreement between INEL and DEMI leading to the construction and testing of electric vehicle-size cells, to be followed eventually by a battery pack. 3 refs., 3 figs., 5 tabs.

  4. Posturography and locomotor tests of dynamic balance after long-duration spaceflight.

    PubMed

    Cohen, Helen S; Kimball, Kay T; Mulavara, Ajitkumar P; Bloomberg, Jacob J; Paloski, William H

    2012-01-01

    The currently approved objective clinical measure of standing balance in astronauts after space flight is the Sensory Organization Test battery of computerized dynamic posturography. No tests of walking balance are currently approved for standard clinical testing of astronauts. This study determined the sensitivity and specificity of standing and walking balance tests for astronauts before and after long-duration space flight. Astronauts were tested on an obstacle avoidance test known as the Functional Mobility Test (FMT) and on the Sensory Organization Test using sway-referenced support surface motion with eyes closed (SOT 5) before and six months after (n=15) space flight on the International Space Station. They were tested two to seven days after landing. Scores on SOT tests decreased and scores on FMT increased significantly from pre- to post-flight. In other words, post-flight scores were worse than pre-flight scores. SOT and FMT scores were not significantly related. ROC analyses indicated supra-clinical cut-points for SOT 5 and for FMT. The standard clinical cut-point for SOT 5 had low sensitivity to post-flight astronauts. Higher cut-points increased sensitivity to post-flight astronauts but decreased specificity to pre-flight astronauts. Using an FMT cut-point that was moderately highly sensitive and highly specific plus SOT 5 at the standard clinical cut-point was no more sensitive than SOT 5, alone. FMT plus SOT 5 at higher cut-points was more specific and more sensitive. The total correctly classified was highest for FMT, alone, and for FMT plus SOT 5 at the highest cut-point. These findings indicate that standard clinical comparisons are not useful for identifying problems. Testing both standing and walking balance will be more likely to identify balance deficits.

  5. The Computerization of the National Library in Paris.

    ERIC Educational Resources Information Center

    Lerin, Christian; Bernard, Annick

    1986-01-01

    Describes the organization and automation plan of the Bibliotheque Nationale (Paris, France) that was begun in 1981. Highlights include the method of moving toward computerization; technical choices; the choosing procedure (pre-qualification, bench-mark test); short term and pilot operations; and preparation for the implementation of the…

  6. Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Chapman, P.

    1982-01-01

    Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

  7. Baseline Field Testing of BB-2590 Lithium-Ion Batteries using an iRobot FasTac 510 Robot

    DTIC Science & Technology

    2010-09-17

    No. 21320 Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot FasTac 510 Robot U.S. Army Tank...SEP 2010 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot...COVERED (From - To) Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an 4. TITLE AND SUBTITLE iRobot FasTac 510 Robot 5a. CONTRACT

  8. Accelerated and real-time geosynchronous life cycling test performance of nickel-hydrogen batteries

    NASA Technical Reports Server (NTRS)

    Green, R. S.

    1985-01-01

    RCA Astro-Electronics currently has four nickel-hydrogen storage battery modules (11 cells each) on test in simulated geosynchronous life cycle regimes. These battery modules are of identical design to those used on the GSTAR (GTE Satellite Corp.) and Spacenet (GTE Spacenet Corp.) communications satellites. The batteries are being tested using an automated test station equipped with computer-controlled environmental chambers and recording equipment. The two battery types, 30 ampere-hours and 40 ampere-hours (GSTAR and Spacenet, respectively), are being electrically cycled using identical 44-day eclipse sequences at 5 C and vary with respect to depth of discharge, recharge ratio, duration of accumulated suntime, and the use of a reconditioning sequence. The test parameters are outlined and the preliminary test data and results are presented.

  9. Cognitive task performance and frequency of alcohol usage in young adults.

    PubMed

    Harvanko, Arit M; Odlaug, Brian L; Schreiber, Liana R N; Grant, Jon E

    2012-06-01

    The goal of our study was to examine cognitive effects of alcohol in young adults at varied levels of alcohol usage using well-validated computerized cognitive measures. One hundred fifty-five young adults (mean age: 21.15 ± 3.092 years; 25.8% female), free from non-alcohol-related psychiatric diagnoses and drug use, underwent selected tests from the Cambridge Neuropsychological Test Automated Battery in conjunction with the Barratt Impulsivity Scale, Eysenck Impulsivity Questionnaire, and the Tridimensional Personality Questionnaire. Study participants were grouped according to alcohol frequency: nondrinkers, at-risk drinkers (subsyndromal alcohol usage), and alcohol use disorder. At-risk drinkers and individuals with alcohol use disorders bet significantly more overall on the Cambridge Gambling Task than nondrinkers. There were no significant differences noted between groups on the Spatial Working Memory task or Intra-dimensional/Extra-dimensional Set Shift task. Individuals with alcohol use disorders endorsed higher impulsivity than at-risk and nondrinkers on the Barratt Impulsivity Scale and Eysenck Impulsivity Questionnaire. Individuals with alcohol use disorders and at-risk drinkers also endorsed higher venturesomeness than nondrinkers on the Tridimensional Personality Questionnaire. Results from the Cambridge Gambling Task suggest that even at a subsyndromal level, young adults make risky decisions that mirror those seen in individuals with alcohol use disorders.

  10. Computerized Adaptive Testing System Design: Preliminary Design Considerations.

    DTIC Science & Technology

    1982-07-01

    the administrative or operational requirements of CAT and presented - # k*----.,ku nh-n.-utu (IPOI efi~g.2me (PMU tQ7q. vim NPRDC TR 82-52 July 1982...design model for a computerized adaptive testing ( CAT ) system was developed and presented through a series of hierarchy plus input-process-output (HIPO...physical system was addressed through brief discussions of hardware, software, interfaces, and personnel requirements. Further steps in CAT system

  11. The Psychology Experiment Building Language (PEBL) and PEBL Test Battery.

    PubMed

    Mueller, Shane T; Piper, Brian J

    2014-01-30

    We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. We describe the PEBL Test Battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. We report the results of benchmark tests that establish the timing precision of PEBL. We consider alternatives to the PEBL system and battery tests. We conclude with a discussion of the ethical factors involved in the open source testing movement. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. The Psychology Experiment Building Language (PEBL) and PEBL Test Battery

    PubMed Central

    Mueller, Shane T.; Piper, Brian J.

    2014-01-01

    Background We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. New Method We describe the PEBL test battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. Results We report the results of benchmark tests that establish the timing precision of PEBL. Comparison with Existing Method We consider alternatives to the PEBL system and battery tests. Conclusions We conclude with a discussion of the ethical factors involved in the open source testing movement. PMID:24269254

  13. Low Temperature Life-cycle Testing of a Lithium-ion Battery for Low-earth-orbiting Spacecraft

    NASA Technical Reports Server (NTRS)

    Reid, Concha

    2004-01-01

    A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 lander is undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their low specific energy, low energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned mission. This paper discusses the performance of the 28 volt, 25 ampere-hour battery through 6000 LEO cycles, which corresponds to one year on LEO orbit. Testing is being performed at 0 C and 40% depth-of-discharge. Individual cell behaviors and their effect on the performance of the battery are described. Capacity, impedance, energy efficiency and end-of-discharge voltage at 1000 cycle intervals are reported. Results from this life-testing will help contribute to the database on battery-level performance of aerospace Li-ion batteries and low temperature cycling under LEO conditions.

  14. Safety modelling and testing of lithium-ion batteries in electrified vehicles

    NASA Astrophysics Data System (ADS)

    Deng, Jie; Bae, Chulheung; Marcicki, James; Masias, Alvaro; Miller, Theodore

    2018-04-01

    To optimize the safety of batteries, it is important to understand their behaviours when subjected to abuse conditions. Most early efforts in battery safety modelling focused on either one battery cell or a single field of interest such as mechanical or thermal failure. These efforts may not completely reflect the failure of batteries in automotive applications, where various physical processes can take place in a large number of cells simultaneously. In this Perspective, we review modelling and testing approaches for battery safety under abuse conditions. We then propose a general framework for large-scale multi-physics modelling and experimental work to address safety issues of automotive batteries in real-world applications. In particular, we consider modelling coupled mechanical, electrical, electrochemical and thermal behaviours of batteries, and explore strategies to extend simulations to the battery module and pack level. Moreover, we evaluate safety test approaches for an entire range of automotive hardware sets from cell to pack. We also discuss challenges in building this framework and directions for its future development.

  15. Advanced lead acid battery development project. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-02-01

    This project involved laboratory and road testing of the Horizon (registered) advanced lead acid batteries produced by Electrosource, Inc. A variety of electric vehicles in the fleet operated by the Sacramento Municipal Utility District and McClellan Air Force Base were used for road tests. The project was sponsored by the Defense Advanced Research Projects Agency under RA 93-23 entitled Electric Vehicle Technology and Infrastructure. The Horizon battery is a valve regulated, or sealed, lead acid battery produced in a variety of sizes and performance levels. During the project, several design and process improvements on the Horizon battery resulted in amore » production battery with a specific energy approaching 45 watt-hours per kilogram (Whr/kg) capable of delivering a peak current of 450 amps. The 12 volt, 95 amp-hour (Ahr) Horizon battery, model number 12N95, was placed into service in seven (7) test vehicles, including sedans, prototype lightweight electric vehicles, and passenger vans. Over 20,000 miles have been driven to date on vehicles powered by the Horizon battery. Road test results indicate that when the battery pack is used with a compatible charger and charge management system, noticeably improved acceleration characteristics are evident, and the vehicles provide a useful range almost 20% greater than with conventional lead-acid batteries.« less

  16. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  17. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-12-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  18. Causal Analysis For Occurrence Report OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbes, Elizabeth H.

    2015-08-01

    On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room;more » initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.« less

  19. Psychometric evaluation of a motor control test battery of the craniofacial region.

    PubMed

    von Piekartz, H; Stotz, E; Both, A; Bahn, G; Armijo-Olivo, S; Ballenberger, N

    2017-12-01

    The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region. © 2017 John Wiley & Sons Ltd.

  20. A field operational test on valve-regulated lead-acid absorbent-glass-mat batteries in micro-hybrid electric vehicles. Part I. Results based on kernel density estimation

    NASA Astrophysics Data System (ADS)

    Schaeck, S.; Karspeck, T.; Ott, C.; Weckler, M.; Stoermer, A. O.

    2011-03-01

    In March 2007 the BMW Group has launched the micro-hybrid functions brake energy regeneration (BER) and automatic start and stop function (ASSF). Valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology are applied in vehicles with micro-hybrid power system (MHPS). In both part I and part II of this publication vehicles with MHPS and AGM batteries are subject to a field operational test (FOT). Test vehicles with conventional power system (CPS) and flooded batteries were used as a reference. In the FOT sample batteries were mounted several times and electrically tested in the laboratory intermediately. Vehicle- and battery-related diagnosis data were read out for each test run and were matched with laboratory data in a data base. The FOT data were analyzed by the use of two-dimensional, nonparametric kernel estimation for clear data presentation. The data show that capacity loss in the MHPS is comparable to the CPS. However, the influence of mileage performance, which cannot be separated, suggests that battery stress is enhanced in the MHPS although a battery refresh function is applied. Anyway, the FOT demonstrates the unsuitability of flooded batteries for the MHPS because of high early capacity loss due to acid stratification and because of vanishing cranking performance due to increasing internal resistance. Furthermore, the lack of dynamic charge acceptance for high energy regeneration efficiency is illustrated. Under the presented FOT conditions charge acceptance of lead-acid (LA) batteries decreases to less than one third for about half of the sample batteries compared to new battery condition. In part II of this publication FOT data are presented by multiple regression analysis (Schaeck et al., submitted for publication [1]).

  1. Computer-Based and Paper-Based Measurement of Semantic Knowledge

    DTIC Science & Technology

    1989-01-01

    of Personality Assessment , 34, 353-361. McArthur, D. L., & Choppin, B. H. (1984). Computerized diagnostic testing. Journal 15 of Educational...Computers in Human Behavior, 1, 49-58. Lushene, R. E., O’Neii, H. F., & Dunn, T. (1974). Equivalent validity of a completely computerized MMPI. Journal

  2. An Application of Computerized Instructional Television in Biology.

    ERIC Educational Resources Information Center

    Kendrick, Bryce

    Computerized instructional television was used to teach undergraduate students about 100,000 or more extant fungi through an interactive, self testing, teaching program. Students did not find this sophisticated hardware an adequate substitute for the lecture experience and ultimately gave their professor a strong vote of confidence. (Author/JEG)

  3. Laboratory discharge studies of a 6 V alkaline lantern-type battery Eveready Energizer no. 528, under various ambient temperatures (-15 deg C and + 22 deg C) and loads (30 omega and 60 omega)

    NASA Technical Reports Server (NTRS)

    Ahrens, S. T.

    1984-01-01

    The voltages of two Eveready No. 528 batteries, one the test battery, the other the control battery, were simultaneously recorded as they were discharged across 30 omega loads using a dual chart recorder. The test battery was initially put in a freezer at -15 + or - 3 C. After its voltage had fallen to .6 V, it was brought back out into the room at 22 + or - 3 C. A second run was made with 60 omega loads. Assuming a 3.0 V cut-off, the total energy output of the test battery at -15 C was 26 WHr 30 omega and 35 WHr 60 omega, and the corresponding numbers for the control battery at 22 C were 91 WHr and 100 WHr. When the test battery was subsequently allowed to warm up, the voltage rose above 4 V and the total energy output rose to 80 WHr 30 omega and 82 WHR 60 omega.

  4. The importance of proper administration and interpretation of neuropsychological baseline and postconcussion computerized testing.

    PubMed

    Moser, Rosemarie Scolaro; Schatz, Philip; Lichtenstein, Jonathan D

    2015-01-01

    Media coverage, litigation, and new legislation have resulted in a heightened awareness of the prevalence of sports concussion in both adult and youth athletes. Baseline and postconcussion testing is now commonly used for the assessment and management of sports-related concussion in schools and in youth sports leagues. With increased use of computerized neurocognitive sports concussion testing, there is a need for standards for proper administration and interpretation. To date, there has been a lack of standardized procedures by which assessments are administered. More specifically, individuals who are not properly trained often interpret test results, and their methods of interpretation vary considerably. The purpose of this article is to outline factors affecting the validity of test results, to provide examples of misuse and misinterpretation of test results, and to communicate the need to administer testing in the most effective and useful manner. An increase in the quality of test administration and application may serve to decrease the prevalence of invalid test results and increase the accuracy and utility of baseline test results if an athlete sustains a concussion. Standards for test use should model the American Psychological Association and Centers for Disease Control and Prevention guidelines, as well as the recent findings of the joint position paper on computerized neuropsychological assessment devices.

  5. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    NASA Technical Reports Server (NTRS)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  6. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    NASA Technical Reports Server (NTRS)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  7. Electric vehicle energy management system

    NASA Astrophysics Data System (ADS)

    Alaoui, Chakib

    This thesis investigates and analyzes novel strategies for the optimum energy management of electric vehicles (EVs). These are aimed to maximize the useful life of the EV batteries and make the EV more practical in order to increase its acceptability to market. The first strategy concerns the right choice of the batteries for the EV according to the user's driving habits, which may vary. Tests conducted at the University of Massachusetts Lowell battery lab show that the batteries perform differently from one manufacturer to the other. The second strategy was to investigate the fast chargeability of different batteries, which leads to reduce the time needed to recharge the EV battery pack. Tests were conducted again to prove that only few battery types could be fast charged. Test data were used to design a fast battery charger that could be installed in an EV charging station. The third strategy was the design, fabrication and application of an Electric Vehicle Diagnostic and Rejuvenation System (EVDRS). This system is based on Mosfet Controlled Thyristors (MCTs). It is capable of quickly identifying any failing battery(s) within the EV pack and rejuvenating the whole battery pack without dismantling them and unloading them. A novel algorithm to rejuvenate Electric Vehicle Sealed Lead Acid Batteries is described. This rejuvenation extends the useful life of the batteries and makes the EV more competitive. The fourth strategy was to design a thermal management system for EV, which is crucial to the safe operation, and the achievement of normal/optimal performance of, electric vehicle (EV) batteries. A novel approach for EV thermal management, based on Pettier-Effect heat pumps, was designed, fabricated and tested in EV. It shows the application of this type of technology for thermal management of EVs.

  8. The cognitive cost of anticholinergic burden: decreased response to cognitive training in schizophrenia.

    PubMed

    Vinogradov, Sophia; Fisher, Melissa; Warm, Heather; Holland, Christine; Kirshner, Margaret A; Pollock, Bruce G

    2009-09-01

    Schizophrenia is treated with medications that raise serum anticholinergic activity and are known to adversely affect cognition. The authors examined the relationship between serum anticholinergic activity and baseline cognitive performance and response to computerized cognitive training in outpatients with schizophrenia. Fifty-five patients were randomly assigned to either computerized cognitive training or a computer games control condition. A neurocognitive battery based on the Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) initiative was performed at baseline and after the intervention. Serum anticholinergic activity, measured at study entry by radioreceptor assay, was available for 49 patients. Serum anticholinergic activity showed a significant negative correlation with baseline performance in verbal working memory and verbal learning and memory, accounting for 7% of the variance in these measures, independent of age, IQ, or symptom severity. Patients in the cognitive training condition (N=25) showed a significant gain in global cognition compared to those in the control condition, but this improvement was negatively correlated with anticholinergic burden. Serum anticholinergic activity uniquely accounted for 20% of the variance in global cognition change, independent of age, IQ, or symptom severity. Serum anticholinergic activity in schizophrenia patients shows a significant association with impaired performance in MATRICS-based measures of verbal working memory and verbal learning and memory and is significantly associated with a lowered response to an intensive course of computerized cognitive training. These findings underscore the cognitive cost of medications that carry a high anticholinergic burden. The findings also have implications for the design and evaluation of cognitive treatments for schizophrenia.

  9. 30 CFR 7.46 - Impact test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.46 Impact test. (a) Test... at 122 °F (50 °C) for a period of 48 hours. (2) Mount the covers on a battery box of the same design with which the covers are to be approved, including any support blocks, with the battery cells...

  10. Battery Calendar Life Estimator Manual Modeling and Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jon P. Christophersen; Ira Bloom; Ed Thomas

    2012-10-01

    The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.

  11. Battery Life Estimator Manual Linear Modeling and Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jon P. Christophersen; Ira Bloom; Ed Thomas

    2009-08-01

    The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, W.; Shiota, T.

    Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990`s are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, W.; Shiota, T.

    Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990's are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.

  14. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    PubMed

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  15. The Construction and Analysis of a Test Battery Related to Volleyball Playing Capacity in Females.

    ERIC Educational Resources Information Center

    Disch, James G.; And Others

    The purpose of this report was to analyze a test battery constructed to describe and predict volleyball playing capacity in college and high school women. The following criteria were used for selecting a test for initial inclusion into the battery: (1) The test is related to a basic motor ability important to playing volleyball; (2) The test can…

  16. Computerized Neuropsychological Assessment Devices: Joint Position Paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology†

    PubMed Central

    Bauer, Russell M.; Iverson, Grant L.; Cernich, Alison N.; Binder, Laurence M.; Ruff, Ronald M.; Naugle, Richard I.

    2012-01-01

    This joint position paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology sets forth our position on appropriate standards and conventions for computerized neuropsychological assessment devices (CNADs). In this paper, we first define CNADs and distinguish them from examiner-administered neuropsychological instruments. We then set forth position statements on eight key issues relevant to the development and use of CNADs in the healthcare setting. These statements address (a) device marketing and performance claims made by developers of CNADs; (b) issues involved in appropriate end-users for administration and interpretation of CNADs; (c) technical (hardware/software/firmware) issues; (d) privacy, data security, identity verification, and testing environment; (e) psychometric development issues, especially reliability, and validity; (f) cultural, experiential, and disability factors affecting examinee interaction with CNADs; (g) use of computerized testing and reporting services; and (h) the need for checks on response validity and effort in the CNAD environment. This paper is intended to provide guidance for test developers and users of CNADs that will promote accurate and appropriate use of computerized tests in a way that maximizes clinical utility and minimizes risks of misuse. The positions taken in this paper are put forth with an eye toward balancing the need to make validated CNADs accessible to otherwise underserved patients with the need to ensure that such tests are developed and utilized competently, appropriately, and with due concern for patient welfare and quality of care. PMID:22382386

  17. Computerized Neuropsychological Assessment Devices: Joint Position Paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology†

    PubMed Central

    Bauer, Russell M.; Iverson, Grant L.; Cernich, Alison N.; Binder, Laurence M.; Ruff, Ronald M.; Naugle, Richard I.

    2013-01-01

    This joint position paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology sets forth our position on appropriate standards and conventions for computerized neuropsychological assessment devices (CNADs). In this paper, we first define CNADs and distinguish them from examiner-administered neuropsychological instruments. We then set forth position statements on eight key issues relevant to the development and use of CNADs in the healthcare setting. These statements address (a) device marketing and performance claims made by developers of CNADs; (b) issues involved in appropriate end-users for administration and interpretation of CNADs; (c) technical (hardware/software/firmware) issues; (d) privacy, data security, identity verification, and testing environment; (e) psychometric development issues, especially reliability and validity; (f) cultural, experiential, and disability factors affecting examinee interaction with CNADs; (g) use of computerized testing and reporting services; and (h) the need for checks on response validity and effort in the CNAD environment. This paper is intended to provide guidance for test developers and users of CNADs that will promote accurate and appropriate use of computerized tests in a way that maximizes clinical utility and minimizes risks of misuse. The positions taken in this paper are put forth with an eye toward balancing the need to make validated CNADs accessible to otherwise underserved patients with the need to ensure that such tests are developed and utilized competently, appropriately, and with due concern for patient welfare and quality of care. PMID:22394228

  18. Computerized Adaptive Testing Project: Objectives and Requirements.

    DTIC Science & Technology

    1982-07-01

    developing a cqmputerlzed adaptive lwfb system ( CAT ). SiN 0102- LP. Old. "O AM"- S/M "of F.g~ smuuim ftmAYUSN 0 IM ~ A joint-service coordinated effort is In...progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the Military Enlistment Processing Stations...lead laboratory for this effort. This report is intended to serve as a working paper documenting CAT system functional requirements and schedules. It

  19. What Do Battery Testers Test?

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1996-01-01

    Presents activities to determine whether it is better to test dry cells with an ammeter than with a voltmeter and how best to test alkaline batteries. Discusses classification of disposable testers as instruments. Concludes that a laboratory voltmeter gives a good indication of the condition of an alkaline cell while carbon batteries are best…

  20. Performance and safety testing of lithium batteries for the Expendable, Mobile, ASW Training Target (EMATT)

    NASA Astrophysics Data System (ADS)

    Hallal, P. B.; Bis, R. F.

    1986-08-01

    The developmental EMATT (expendable, mobile, ASW training target) may use a high-energy (lithium/sulfuryl chloride) battery system. Safety problems with the original battery cell design were experienced during early performance and safety testing. After redesign of the battery cell, performance and safety tests were made under specified abuse conditions, as well as under simulated launch conditions. The test results showed that the power system now meets all safety requirements, and that the EMATT vehicle is safe to deploy for its engineering development phase.

  1. Human-rated Safety Certification of a High Voltage Robonaut Lithium-ion Battery

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith; Yayathi, S.; Johnson, M.; Waligora, T.; Verdeyen, W.

    2013-01-01

    NASA's rigorous certification process is being followed for the R2 high voltage battery program for use of R2 on International Space Station (ISS). Rigorous development testing at appropriate levels to credible off-nominal conditions and review of test data led to design improvements for safety at the virtual cell, cartridge and battery levels. Tests were carried out at all levels to confirm that both hardware and software controls work. Stringent flight acceptance testing of the flight battery will be completed before launch for mission use on ISS.

  2. A differential approach to microcomputer test battery development and implementation

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Baltzley, D. R.; Osteen, M. K.; Turnage, J. J.

    1988-01-01

    The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

  3. NREL Scientists and Engineers Recognized for Top Innovations | NREL | News

    Science.gov Websites

    commercially available, large-format isothermal battery calorimeter for lithium-ion battery safety testing to test the performance and safety of large-format lithium-ion batteries used extensively in electric develop NREL intellectual property representing an isothermal battery calorimeter. The technical

  4. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sally; Tyler Gray; Pattie Hovorka

    2012-08-01

    The UltraBattery Retrofit Project DP1.8 and Carbon Enriched Project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy and the Advanced Lead Acid Battery Consortium (ALABC), are established to demonstrate the suitability of advanced lead battery technology in hybrid electrical vehicles (HEVs). A profile, termed the “Simulated Honda Civic HEV Profile” (SHCHEVP) has been developed in Project DP1.8 in order to provide reproducible laboratory evaluations of different battery types under real-world HEV conditions. The cycle is based on the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles and simulates operation of amore » battery pack in a Honda Civic HEV. One pass through the SHCHEVP takes 2,140 seconds and simulates 17.7 miles of driving. A complete nickel metal hydride (NiMH) battery pack was removed from a Honda Civic HEV and operated under SHCHEVP to validate the profile. The voltage behavior and energy balance of the battery during this operation was virtually the same as that displayed by the battery when in the Honda Civic operating on the dynamometer under the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles, thus confirming the efficacy of the simulated profile. An important objective of the project has been to benchmark the performance of the UltraBatteries manufactured by both Furukawa Battery Co., Ltd., Japan (Furakawa) and East Penn Manufacturing Co., Inc. (East Penn). Accordingly, UltraBattery packs from both Furakawa and East Penn have been characterized under a range of conditions. Resistance measurements and capacity tests at various rates show that both battery types are very similar in performance. Both technologies, as well as a standard lead-acid module (included for baseline data), were evaluated under a simple HEV screening test. Both Furakawa and East Penn UltraBattery packs operated for over 32,000 HEV cycles, with minimal loss in performance; whereas the standard lead-acid unit experienced significant degradation after only 6,273 cycles. The high-carbon, ALABC battery manufactured in Project C3 also was tested under the advanced HEV schedule. Its performance was significantly better than the standard lead-acid unit, but was still inferior compared with the UltraBattery. The batteries supplied by Exide as part of the C3 Project performed well under the HEV screening test, especially at high temperatures. The results suggest that higher operating temperatures may improve the performance of lead-acid-based technologies operated under HEV conditions—it is recommended that life studies be conducted on these technologies under such conditions.« less

  5. Nickel-Hydrogen and Lithium Ion Space Batteries

    NASA Technical Reports Server (NTRS)

    Reid, Robert O., II

    2004-01-01

    The tasks of the Electrochemistry Branch of NASA Glenn Research Center are to improve and develop high energy density and rechargeable, life-long batteries. It is with these batteries that people across the globe are able to power their cell phones, laptop computers, and cameras. Here, at NASA Glenn Research Center, the engineers and scientists of the Electrochemistry branch are leading the way in the development of more powerful, long life batteries that can be used to power space shuttles and satellites. As of now, the cutting edge research and development is being done on nickel-hydrogen batteries and lithium ion batteries. Presently, nickel-hydrogen batteries are common types of batteries that are used to power satellites, space stations, and space shuttles, while lithium batteries are mainly used to power smaller appliances such as portable computers and phones. However, the Electrochemistry Branch at NASA Glenn Research Center is focusing more on the development of lithium ion batteries for deep space use. Because of the limitless possibilities, lithium ion batteries can revolutionize the space industry for the better. When compared to nickel-hydrogen batteries, lithium ion batteries possess more advantages than its counterpart. Lithium ion batteries are much smaller than nickel-hydrogen batteries and also put out more power. They are more energy efficient and operate with much more power at a reduced weight than its counterpart. Lithium ion cells are also cheaper to make, possess flexibility that allow for different design modifications. With those statistics in hand, the Electrochemistry Branch of NASA Glenn has decided to shut down its Nickel-Hydrogen testing for lithium ion battery development. Also, the blackout in the summer of 2003 eliminated vital test data, which played a part in shutting down the program. from the nickel-hydrogen batteries and compare it to past data. My other responsibilities include superheating the electrolyte that is used in the nickel-hydrogen cell in a calorimeter to test its performance under various conditions. 1 used a program called Arbin to study my data. The Arbin allows me to look at different parameters such as pressure and time and how they affect the changing temperature of the electrolyte that is being tested. In addition, I had the responsibility of taking apart and modifying battery coolers that would be used. My mentors told me that the batteries kept shutting down, so it was my responsibility to remove excess fan grilles, rotate the fans, and then switch the aluminum standoffs with nylon ones so that the coolers could operate without problems. My last task is to collect all the battery test data and organize them into charts using Microsoft Excel, before the Branch is able to conduct its research on lithium ion batteries. Therefore, during my tenure, it is my responsibility to take down final test data

  6. Hypervelocity Impact Testing of Nickel Hydrogen Battery Cells

    NASA Technical Reports Server (NTRS)

    Frate, David T.; Nahra, Henry K.

    1996-01-01

    Nickel-Hydrogen (Ni/H2) battery cells have been used on several satellites and are planned for use on the International Space Station. In January 1992, the NASA Lewis Research Center (LeRC) conducted hypervelocity impact testing on Ni/H2 cells to characterize their failure modes. The cell's outer construction was a 24 mil-thick Inconel 718 pressure vessel. A sheet of 1.27 cm thick honeycomb was placed in front of the battery cells during testing to simulate the on-orbit box enclosure. Testing was conducted at the NASA White Sands Test Facility (WSTF). The hypervelocity gun used was a 7.6 mm (0.30 caliber) two-stage light gas gun. Test were performed at speeds of 3, 6, and 7 km/sec using aluminum 2017 spherical particles of either 4.8 or 6.4 mm diameter as the projectile. The battery cells were electrically charged to about 75 percent of capacity, then back-filled with hydrogen gas to 900 psi simulating the full charge condition. High speed film at 10,000 frames/sec was taken of the impacts. Impacts in the dome area (top) and the electrode area (middle) of the battery cells were investigated. Five tests on battery cells were performed. The results revealed that in all of the test conditions investigated, the battery cells simply vented their hydrogen gas and some electrolyte, but did not burst or generate any large debris fragments.

  7. Primary zinc-air batteries for space power

    NASA Technical Reports Server (NTRS)

    Bragg, Bobby J.; Bourland, Deborah S.; Merry, Glenn; Putt, Ron

    1992-01-01

    Prismatic HR and LC cells and batteries were built and tested, and they performed well with respect to the program goals of high capacity and high rate capability at specific energies. The HR batteries suffered reduced utilizations owing to dryout at the 2 and 3 A rates for the 50 C tests owing to the requirement for forced convection. The LC batteries suffered reduced utilizations under all conditions owing to the chimney effect at 1 G, although this effect would not occur at 0 G. An empirical model was developed which accurately predicted utilizations and average voltages for single cells, although thermal effects encountered during battery testing caused significant deviations, both positive and negative, from the model. Based on the encouraging results of the test program, we believe that the zinc-air primary battery of a flat, stackable configuration can serve as a high performance and safe power source for a range of space applications.

  8. Development of a lead-acid battery for a hybrid electric vehicle

    NASA Astrophysics Data System (ADS)

    Cooper, A.

    In September 2000, a project reliable, highly optimized lead-acid battery (RHOLAB) started under the UK Foresight Vehicle Programme with the objective of developing an optimized lead-acid battery solution for hybrid electric vehicles. The work is based on a novel, individual, spirally-wound valve-regulated lead-acid 2 V cell optimized for HEV use and low variability. This cell is being used as a building block for the development of a complete battery pack that is managed at the cell level. Following bench testing, this battery pack is to be thoroughly evaluated by substituting it for the Ni-MH pack in a Honda Insight. The RHOLAB cell is based on the 8 Ah Hawker Cyclon cell which has been modified to have current take-off at both ends—the dual-tab design. In addition, a variant has been produced with modified cell chemistry to help deal with problems that can occur when these valve-regulated lead-acid battery (VRLA) cells operate in a partial-state-of-charge condition. The cells have been cycled to a specially formulated test cycle based on real vehicle data derived from testing the Honda Insight on the various test tracks at the Millbrook Proving Grounds in the UK. These cycling tests have shown that the lead-acid pack can be successfully cycled when subjected to the high current demands from the vehicle, which have been measured at up to 15 C on discharge and 8 C during regenerative recharging, and cycle life is looking very promising under this arduous test regime. Concurrent with this work, battery development has been taking place. It was decided early on to develop the 144 V battery as four 36 V modules. Data collection and control has been built-in and special steps taken to minimize the problems of interconnect in this complex system. Development of the battery modules is now at an advanced stage. The project plan then allows for extensive testing of the vehicle with its lead-acid battery at Millbrook so it can be compared with the benchmark tests which have already been carried out on the vehicle with its Ni-MH batteries.

  9. The Beneficial Effects of Cognitive Training With Simple Calculation and Reading Aloud (SCRA) in the Elderly Postoperative Population: A Pilot Randomized Controlled Trial.

    PubMed

    Kulason, Kay; Nouchi, Rui; Hoshikawa, Yasushi; Noda, Masafumi; Okada, Yoshinori; Kawashima, Ryuta

    2018-01-01

    Background: There has been little research conducted regarding cognitive treatments for the elderly postsurgical population. Patients aged ≥60 years have an increased risk of postoperative cognitive decline, a condition in which cognitive functions are negatively affected. This cognitive decline can lead to a decline in quality of life. In order to maintain a high quality of life, the elderly postsurgical population may benefit from treatment to maintain and/or improve their cognitive functions. This pilot study investigates the effect of simple calculation and reading aloud (SCRA) cognitive training in elderly Japanese postsurgical patients. Methods: Elderly patients undergoing non-cardiovascular thoracic surgery under general anesthesia were recruited ( n = 12). Subjects were randomly divided into two groups-one that receives 12 weeks of SCRA intervention, and a waitlisted control group. Before and after the intervention, we measured cognitive function [Mini-Mental Status Exam-Japanese (MMSE-J), Frontal Assessment Battery (FAB), computerized Cogstate Brief Battery (CBB)] and emotional state [General Health Questionnaire-12 (GHQ-12), Geriatric Depression Scale (GDS), Quality of Life Scale-5 (QOL-5)]. Results: Group difference analyses using ANCOVA with permutation test showed that the intervention SCRA group had a significant improvement in FAB motor programming sub-score, GDS, and QOL-5 compared to the control group. Within-group analyses using Wilcoxon signed-rank test to compare baseline and follow-up showed that the SCRA intervention group total FAB scores, FAB motor programming sub-scores, and QOL-5 scores were significantly improved. Discussion: This pilot study showed that there are important implications for the beneficial effects of SCRA intervention on cognitive function and emotional state in the postoperative elderly population; however, further investigations are necessary to reach any conclusions. Trial registration: This study was registered with the University Hospital Medical Information Network (UMIN) Clinical Trial Registry (UMIN000019832).

  10. The Beneficial Effects of Cognitive Training With Simple Calculation and Reading Aloud (SCRA) in the Elderly Postoperative Population: A Pilot Randomized Controlled Trial

    PubMed Central

    Kulason, Kay; Nouchi, Rui; Hoshikawa, Yasushi; Noda, Masafumi; Okada, Yoshinori; Kawashima, Ryuta

    2018-01-01

    Background: There has been little research conducted regarding cognitive treatments for the elderly postsurgical population. Patients aged ≥60 years have an increased risk of postoperative cognitive decline, a condition in which cognitive functions are negatively affected. This cognitive decline can lead to a decline in quality of life. In order to maintain a high quality of life, the elderly postsurgical population may benefit from treatment to maintain and/or improve their cognitive functions. This pilot study investigates the effect of simple calculation and reading aloud (SCRA) cognitive training in elderly Japanese postsurgical patients. Methods: Elderly patients undergoing non-cardiovascular thoracic surgery under general anesthesia were recruited (n = 12). Subjects were randomly divided into two groups—one that receives 12 weeks of SCRA intervention, and a waitlisted control group. Before and after the intervention, we measured cognitive function [Mini-Mental Status Exam-Japanese (MMSE-J), Frontal Assessment Battery (FAB), computerized Cogstate Brief Battery (CBB)] and emotional state [General Health Questionnaire-12 (GHQ-12), Geriatric Depression Scale (GDS), Quality of Life Scale-5 (QOL-5)]. Results: Group difference analyses using ANCOVA with permutation test showed that the intervention SCRA group had a significant improvement in FAB motor programming sub-score, GDS, and QOL-5 compared to the control group. Within-group analyses using Wilcoxon signed-rank test to compare baseline and follow-up showed that the SCRA intervention group total FAB scores, FAB motor programming sub-scores, and QOL-5 scores were significantly improved. Discussion: This pilot study showed that there are important implications for the beneficial effects of SCRA intervention on cognitive function and emotional state in the postoperative elderly population; however, further investigations are necessary to reach any conclusions. Trial registration: This study was registered with the University Hospital Medical Information Network (UMIN) Clinical Trial Registry (UMIN000019832). PMID:29643802

  11. Is there a link between the hospital-acquired injurious fall rates in US acute care hospitals and these institutions' implementation levels of computerized systems?

    PubMed

    Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi

    2011-12-01

    Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.

  12. Reliability and Validity of the Flemish Physical Activity Computerized Questionnaire in Adults

    ERIC Educational Resources Information Center

    Matton, Lynn; Wijndaele, Katrien; Duvigneaud, Nathalie; Duquet, William; Philippaerts, Renaat; Thomis, Martine; Lefevre, Johan

    2007-01-01

    The purpose of this study was to investigate the test-retest reliability and concurrent validity of the Flemish Physical Activity Computerized Questionnaire (FPACQ) in employed/unemployed and retired people. The FPACQ was developed to assess detailed information on several dimensions of physical activity and sedentary behavior over a usual week. A…

  13. Evaluating the Validity of Computerized Content Analysis Programs for Identification of Emotional Expression in Cancer Narratives

    ERIC Educational Resources Information Center

    Bantum, Erin O'Carroll; Owen, Jason E.

    2009-01-01

    Psychological interventions provide linguistic data that are particularly useful for testing mechanisms of action and improving intervention methodologies. For this study, emotional expression in an Internet-based intervention for women with breast cancer (n = 63) was analyzed via rater coding and 2 computerized coding methods (Linguistic Inquiry…

  14. Planning Future Instructional Programs through Computerized L2 Dynamic Assessment

    ERIC Educational Resources Information Center

    Ebadi, Saman; Saeedian, Abdulbaset

    2016-01-01

    Dynamic Assessment (DA) is a postmodern notion in testing which sees instruction and assessment as inextricably mingled contending that learners will progress if provided with dynamic interactions. The main purpose of the study is to see if the scores generated by the computerized dynamic assessment (C-DA) which is grounded in Vygotsky's…

  15. Development and Implementation of a Hardware In-the-Loop Test Bed for Unmanned Aerial Vehicle Control Algorithms

    NASA Technical Reports Server (NTRS)

    Nyangweso, Emmanuel; Bole, Brian

    2014-01-01

    Successful prediction and management of battery life using prognostic algorithms through ground and flight tests is important for performance evaluation of electrical systems. This paper details the design of test beds suitable for replicating loading profiles that would be encountered in deployed electrical systems. The test bed data will be used to develop and validate prognostic algorithms for predicting battery discharge time and battery failure time. Online battery prognostic algorithms will enable health management strategies. The platform used for algorithm demonstration is the EDGE 540T electric unmanned aerial vehicle (UAV). The fully designed test beds developed and detailed in this paper can be used to conduct battery life tests by controlling current and recording voltage and temperature to develop a model that makes a prediction of end-of-charge and end-of-life of the system based on rapid state of health (SOH) assessment.

  16. Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions

    NASA Technical Reports Server (NTRS)

    Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L. D.; Puglia, F. J.; Santee, S.; Gitzendanner, R.

    2009-01-01

    NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.

  17. Laboratory testing of GNB switch 12 volt SLI (starting, lighting and ignition) battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.

    1990-03-01

    The purpose of this report is to describe the testing performed on the GNB Switch flooded lead SLI battery in the INEL Electric Vehicle Battery Laboratory, to present the results and conclusions of this testing, and to make appropriate recommendations. GNB Inc. is a Pacific Dunlop Company. The term SWITCH'' comes from the fact that this product consists of two batteries in one package which can be connected in parallel by a switch for higher cranking energy or reserve capacity. The smaller second battery is float charged through a diode. GNB advertising describes the SWITCH'' as The Battery With Amore » Spare''. The Switch, a BCI Group 24 SLI (Starting, Lighting and Ignition) battery, is manufactured in Georgia for sale throughout the US. The initial design work on the Switch was done in Australia under the Pulsar name by Dunlop. 11 figs., 3 tabs.« less

  18. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  19. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  20. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  1. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    PubMed Central

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468

  2. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    PubMed

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  3. Design techniques for developing a computerized instrumentation test plan. [for wind tunnel test data acquisition system

    NASA Technical Reports Server (NTRS)

    Burnett, S. Kay; Forsyth, Theodore J.; Maynard, Everett E.

    1987-01-01

    The development of a computerized instrumentation test plan (ITP) for the NASA/Ames Research Center National Full Scale Aerodynamics Complex (NFAC) is discussed. The objective of the ITP program was to aid the instrumentation engineer in documenting the configuration and calibration of data acquisition systems for a given test at any of four low speed wind tunnel facilities (Outdoor Aerodynamic Research Facility, 7 x 10, 40 x 80, and 80 x 120) at the NFAC. It is noted that automation of the ITP has decreased errors, engineering hours, and setup time while adding a higher level of consistency and traceability.

  4. Evaluation of a new charge algorithm for a lead-acid battery with gelled electrolyte using a 96V gel cell IV as a test battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowak, D.K.

    1989-10-01

    This document has reported a summary of test results obtained utilizing the new UAH charge algorithm for Lead-Acid batteries with gelled electrolyte. The battery performance data for a 96V Phase IV Gel/Cell battery pack was tested in a Jet Industries Electrica vehicle. It was shown that the new charge concept is sound although there can be problems with batteries that are highly imbalanced and where excessive electronic noise is experienced on the electronic signal feed-back line that carries the voltage sensor signals from the battery. Additional work is needed to add intelligence to the charge algorithm in terms of amore » better ability to extract the beginning of gas development from the voltage spread function. This can probably be accomplished by scanning the voltages more often and including that data into the function analysis by adding software filters. The Phase IV Gel/Cell battery performance was found to be about 20% lower than that of the Phase III Gel/Cell battery. Problems with cell valve leakage were encountered in the Phase IV Gel/Cell that pose a threat to battery life although so far no battery module has been lost. 2 refs., 13 figs., 4 tabs.« less

  5. Commercial aerospace and terrestrial applications of nickel-hydrogen batteries

    NASA Astrophysics Data System (ADS)

    Caldwell, Dwight B.; Coates, Dwaine K.; Fox, Chris L.; Miller, Lee E.

    1996-03-01

    The nickel-hydrogen battery system, used extensively in the aerospace industry to supply electrical power to earth-orbital satellites for communications, observation, and military applications, is being developed for commercial, terrestrial applications. Low-cost components, electrodes, cell designs, and battery designs are currently being tested. Catalytic hydrogen electrodes have been developed which are compatible with commercial nickel battery cost. Prismatic and spiral-wound cell designs have been built and tested. Common pressure vessel and dependent pressure vessel battery designs are also being evaluated. The nickel-hydrogen battery offers potential cycle life unequaled by any other battery system. This makes the battery ideal for many commercial and terrestrial energy storage applications such as telecommunication, remote stand-alone power systems, utility load-leveling, and other applications which require long life and a truly maintenance-free and abuse-tolerant battery system.

  6. Battery cycling and calendar aging: year one testing results.

    DOT National Transportation Integrated Search

    2016-07-01

    This report is meant to provide an update on the ongoing battery testing performed by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV batte...

  7. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    NASA Astrophysics Data System (ADS)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  8. Age, sex, and symptom intensity influence test taking parameters on functional patient-reported outcomes.

    PubMed

    Cheville, Andrea L; Wang, Chun; Ni, Pengsheng; Jette, Alan M; Basford, Jeffrey R

    2014-11-01

    Item response theory-based patient-reported outcomes such as the Activity Measure for Post Acute Care Computerized Adaptive Test are gaining use because of their flexibility and ease of administration. Their psychometric properties are being explored, but little is known about how respondent characteristics may impact precision. The goal of this study was, therefore, to assess the effects of age, sex, and symptom intensity on respondents' test taking behaviors and scores. Three hundred eleven adults with late-stage lung cancer were consecutively enrolled between April 2008 and April 2009. Demographics and comorbidities were abstracted from their electronic medical records. The participants were followed on a 3- to 4-wk basis by telephonic interviews that involved administration of the Activity Measure for Post Acute Care Computerized Adaptive Test, followed by numerical rating scales scoring of their pain, fatigue, and dyspnea. In more than 2538 computerized adaptive test (CAT) sessions, three findings were prominent. First, the women and the older patients took longer to complete CAT sessions, were more likely to skip items, and produced scores with larger standard errors. Second, the respondents with higher levels of dyspnea and fatigue, but not pain, completed their CAT sessions more rapidly and were less likely to skip items. Third, fatigue and dyspnea interact with age but not sex to influence CAT duration and skip count. The findings of this study suggest that certain common clinical populations, for example, women, geriatric patients, and patients with intense symptoms, differ systematically in the time they are willing to devote to testing and the precision of their responses. The latter finding, unstable precision, is unlikely to be CAT specific and has implications for the interpretation of the scores of the Activity Measure for Post Acute Care Computerized Adaptive Test and other patient-reported outcomes.

  9. The 1975 GSFC Battery Workshop

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The proceedings of the 1975 Goddard Space Flight Center Battery Workshop are presented. The major topics of discussion were nickel cadmium batteries and, to a lesser extent, nickel hydrogen batteries. Battery design, manufacturing techniques, testing programs, and electrochemical characteristics were considered. The utilization of these batteries for spacecraft power supplies was given particular attention.

  10. Nickelzinc Batteries for RPV Applications.

    DTIC Science & Technology

    1981-06-01

    batteries used in the BQM-34A target drones are: 1) The secondary nickel-zinc system is able to provide superior Amp-Hr capacity with respect to volume as...7) MAR-5013 Flight Test batteries, have been constructed and shipped to Tyndall AFB for testing in the BQM- 34A remotely piloted target drone . The...ditioning.The seventh battery was lost on a flight mission when the target drone was shot down. Refer to Table 16 for a summary of battery history prior

  11. Field testing the Wildlink Capture Collar on wolves

    USGS Publications Warehouse

    Mech, L. David; Gesit, Eric L.

    1992-01-01

    Seventeen Wildlink capture collars were tested 61 times on 18 gray wolves (Canis lupus) during 1989-1991 in the Superior National Forest of northeastern Minnesota. Overall success rate was 89%, and most failures were attributable to premature battery expiration. When batteries were changed ≤ every 2 months, 17 of 17 tests succeeded. With an upgraded version of the collar in which batteries lasted longer, 17 of 18 tests succeeded. Over the 2-year study, 6 of the 17 collars were lost. For serially recapturing individuals, the Wildlink collar proved useful and reliable if care was taken to replace batteries at proper intervals.

  12. Acceptance Equipment System Data Acquisition and Processing Utility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fakhro, Rowan

    2015-02-01

    My internship at Sandia National Laboratories took place in the Department of Sensors and Embedded Systems, which is tasked with, among many things, the non-destructive testing of thermal batteries. The Acceptance Equipment System (AES) is a flexible rack system designed to electrically test thermal batteries individually for internal defects before they are stored in the battery stock pile. Aside from individual testing, data acquired by the AES is used for many things including trending and catching outliers within the tolerance levels of a particular battery type, allowing for the development of more refined acceptance requirements and testing procedures.

  13. Parametric tests of a 40-Ah bipolar nickel-hydrogen battery

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1986-01-01

    A series of tests were performed to characterize battery performance relating to certain operating parameters which include charge current, discharge current, temperature, and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions.

  14. Semi-Automated Full Battery.

    ERIC Educational Resources Information Center

    Vincent, Ken R.

    1980-01-01

    Presents the format for the development of interpretive statements covering an entire test battery content on both objective tests and projective instruments. This procedure, the semiautomated full battery, can lessen significantly the time and much of the repetition entailed in psychological report writing. (Author)

  15. Neuropsychological Functioning in Obsessive-Compulsive Washers: Drug-Naive Without Depressive Symptoms.

    PubMed

    Saremi, Ali Akbar; Shariat, Seyed Vahid; Nazari, Mohammad Ali; Dolatshahi, Behrooz

    2017-01-01

    Obsessive-Compulsive Disorder (OCD) is a complex and heterogeneous neuropsychiatric syndrome. Contamination obsessions and washing/cleaning compulsions are the most frequent clinical OCD subtypes. The current study aimed at examining the neuropsychological impairments in drug-naive obsessive-compulsive (OC) washers without depressive symptoms and their association with the severity of symptoms. In the current causal-comparative study, 35 patients with diagnostic and statistical mental disorders class (DSM)-IV diagnosed with washing-subtype OCD and 35 healthy subjects were selected by the convenience sampling method and evaluated by computerized neuropsychology battery and clinical tests as Stroop Color-Word Test (SCWT), Wisconsin Card Sorting Test (WCST), Go/No-Go Test, Digits Forward (DF), Digits Backward (DB), Yale-Brown Obsessive-Compulsive Scale (Y-BOCS), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), and General Health Questionnaire (GHQ)-28. The patients were matched to the comparison group with regard to age, gender, intelligence quotient (IQ), education, and handedness. All the tests were standardized in Iran. SPSS version 20.00 was used for descriptive and analytical data analysis. There was no statistically significant different between the OCD washing and the control groups regarding socio-demographic variables or IQ. There were significant differences between the OC washer and the healthy control groups on the neuropsychological functioning. The obtained results suggested that OC washers performed significantly worse on neuropsychological measures than the controls. There was no significant association between the severity of OC symptoms and the neuropsychological functions in the OCD washing group. It was concluded that executive function impairment, which is a core feature in OC washers was trait-like in nature.

  16. Battery algorithm verification and development using hardware-in-the-loop testing

    NASA Astrophysics Data System (ADS)

    He, Yongsheng; Liu, Wei; Koch, Brain J.

    Battery algorithms play a vital role in hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), extended-range electric vehicles (EREVs), and electric vehicles (EVs). The energy management of hybrid and electric propulsion systems needs to rely on accurate information on the state of the battery in order to determine the optimal electric drive without abusing the battery. In this study, a cell-level hardware-in-the-loop (HIL) system is used to verify and develop state of charge (SOC) and power capability predictions of embedded battery algorithms for various vehicle applications. Two different batteries were selected as representative examples to illustrate the battery algorithm verification and development procedure. One is a lithium-ion battery with a conventional metal oxide cathode, which is a power battery for HEV applications. The other is a lithium-ion battery with an iron phosphate (LiFePO 4) cathode, which is an energy battery for applications in PHEVs, EREVs, and EVs. The battery cell HIL testing provided valuable data and critical guidance to evaluate the accuracy of the developed battery algorithms, to accelerate battery algorithm future development and improvement, and to reduce hybrid/electric vehicle system development time and costs.

  17. The 1984 Goddard Space Flight Center Battery Workshop

    NASA Technical Reports Server (NTRS)

    Morrow, G. W. (Editor)

    1985-01-01

    Various topics related to spacecraft power supply systems are discussed. Regenerative fuel cells, lithium molybdenum batteries, nickel hydrogen batteries, nickel cadmium batteries, failure analysis, and performance testing are covered.

  18. Energy Storage Requirements & Challenges for Ground Vehicles

    DTIC Science & Technology

    2010-03-18

    Titinate Evaluation Cell Evaluation Battery Aging Phenomenon Battery SOC/SOH Determination Modeling ARM 100 LiIon APU Lion Cell Evaluation Cell...Advanced Batteries Fuels Th er m al Ma na ge m en t Radiators Heat Recovery Thermal Interface Materials Phase Change Cooling Advanced Electronics...in all energy storage Energy Storage Team Mission Battery Technology Evaluation Lab Module Test & Eval Cell Test & Eval 6UNCLASSIFIED Pacing Vehicle

  19. TARDEC Brief to OnPoint Technologies

    DTIC Science & Technology

    2007-02-28

    in Aberdeen, MD with Lithium - ion battery packs. - The vehicle will undergo many tests using a 15kW-hr battery pack. 30 Other Battery Related...battery, operation requires that the battery be maintained in a heated condition. NiMH - NiMH is the first fall back position after the Lithium Ion battery chemistry

  20. International Space Station Lithium-Ion Battery

    NASA Technical Reports Server (NTRS)

    Dalton, Penni J.; Schwanbeck, Eugene; North, Tim; Balcer, Sonia

    2016-01-01

    The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.

  1. End User Acceptance - Requirements or Specifications, Certification, Testing

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2013-01-01

    NASA follows top level safety requirement of two-failure tolerance (t hree levels of controls or design for minimum risk) to all catastroph ic hazards in the design of safe li-ion batteries for space use. ? R igorous development testing at appropriate levels to credible offnominal conditions and review of test data. ? Implement robust design con trols based on test results and test again to confirm safety at the a ppropriate levels. ? Stringent testing of all (100%) flight batteries (from button cells to large batteries).

  2. The effect of cell design and test criteria on the series/parallel performance of nickel cadmium cells and batteries

    NASA Technical Reports Server (NTRS)

    Halpert, G.; Webb, D. A.

    1983-01-01

    Three batteries were operated in parallel from a common bus during charge and discharge. SMM utilized NASA Standard 20AH cells and batteries, and LANDSAT-D NASA 50AH cells and batteries of a similar design. Each battery consisted of 22 series connected cells providing the nominal 28V bus. The three batteries were charged in parallel using the voltage limit/current taper mode wherein the voltage limit was temperature compensated. Discharge occurred on the demand of the spacecraft instruments and electronics. Both flights were planned for three to five year missions. The series/parallel configuration of cells and batteries for the 3-5 yr mission required a well controlled product with built-in reliability and uniformity. Examples of how component, cell and battery selection methods affect the uniformity of the series/parallel operation of the batteries both in testing and in flight are given.

  3. Parameters of Emotional Processing in Neuropsychiatric Disorders: Conceptual Issues and a Battery of Tests.

    ERIC Educational Resources Information Center

    Borod, Joan C.; And Others

    1990-01-01

    Components of emotional processing (communication channel, processing mode, and emotional valence) were examined in psychiatric and neurological populations, using an experimental affect battery. The test battery exhibited good psychometric properties and discriminated among diagnostic groups. (Author/JDD)

  4. Informap... a computerized information system for fire planning and fire control

    Treesearch

    Theodore G. Storey; Ross D. Carder; Ernest T. Tolin

    1969-01-01

    INFORMAP (Information Necessary for Optimum Resource Management and Protection) is a computerized system under development for storing, manipulating, retrieving, and displaying data for fire planning and fire control. A prototype for planning applications has been developed and tested. It is programed in Fortran IV for the IBM 7040 computer, and displays information in...

  5. The Effects of Computerized Symbol Processor Instruction on the Communication Skills of Nonspeaking Students.

    ERIC Educational Resources Information Center

    Osguthorpe, Russell T.; Li Chang, Linda

    1988-01-01

    A computerized symbol processor system using an Apple IIe computer and a Power Pad graphics tablet was tested with 22 nonspeaking, multiply disabled students. The students were taught to express themselves independently in writing, and they did significantly better than control students on measures of language comprehension and symbol recognition.…

  6. Improving Emergency Department Triage Classification with Computerized Clinical Decision Support at a Pediatric Hospital

    ERIC Educational Resources Information Center

    Kunisch, Joseph Martin

    2012-01-01

    Background: The Emergency Severity Index (ESI) is an emergency department (ED) triage classification system based on estimated patient-specific resource utilization. Rules for a computerized clinical decision support (CDS) system based on a patient's chief complaint were developed and tested using a stochastic model for predicting ESI scores.…

  7. Computerized Aid Improves Safety Decision Process for Survivors of Intimate Partner Violence

    ERIC Educational Resources Information Center

    Glass, Nancy; Eden, Karen B.; Bloom, Tina; Perrin, Nancy

    2010-01-01

    A computerized safety decision aid was developed and tested with Spanish or English-speaking abused women in shelters or domestic violence (DV) support groups (n = 90). The decision aid provides feedback about risk for lethal violence, options for safety, assistance with setting priorities for safety, and a safety plan personalized to the user.…

  8. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  9. Evaluating Maintenance Performance: The Development and Tryout of Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report for Period January 1969-May 1974.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; Foley, John P., Jr.

    A battery of criterion referenced job task performance tests (JIPT) for typical electronic maintenance activities were developed. The construction of a battery of such tests together with an appropriate scoring for reporting the results is detailed. The development of a Test Administrators Handbook also is described. This battery is considered to…

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daena Kei

    On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glassesmore » and a high temperature glove on the hand that was holding the battery.« less

  11. Prismatic sealed nickel-cadmium batteries utilizing fiber structured electrodes. II - Applications as a maintenance free aircraft battery

    NASA Astrophysics Data System (ADS)

    Anderman, Menahem; Benczur-Urmossy, Gabor; Haschka, Friedrich

    Test data on prismatic sealed Ni-Cd batteries utilizing fiber structured electrodes (sealed FNC) is discussed. It is shown that, under a voltage limited charging scheme, the charge acceptance of the sealed FNC battery is far superior to that of the standard vented aircraft Ni-Cd batteries. This results in the sealed FNC battery maintaining its capacity over several thousand cycles without any need for electrical conditioning or water topping. APU start data demonstrate superior power capabilities over existing technologies. Performance at low temperature is presented. Abuse test results reveal a safe fail mechanism even under severe electrical abuse.

  12. Results of advanced battery technology evaluations for electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1992-10-01

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  13. Crane Cell Testing Support of NASA/Goddard Space Flight Center: An Update

    NASA Technical Reports Server (NTRS)

    Strawn, Mike; David, Jerry; Rao, Gopalakrishna M.

    2001-01-01

    The objectives presented in this viewgraph presentation include: 1) Verify the quality and reliability of aerospace battery cells and batteries for NASA flight programs; 2) Disseminate the data to develop a plan for in-orbit battery management and to design a cell/battery for future NASA spacecraft; and 3) Establish a cell test data base for rechargeable cell/batteries. In summary: quality EPT Ni-H2, EPT Super NiCd and SAFT NiCd cells have been demonstrated for aerospace applications; the data has been provided to NASA Centers and other agencies for their use and application; developed plan and used in NASA in-orbit battery management. Database on rechargeable cell/batteries is now available for customer use.

  14. Neurocognitive functioning in individuals with bipolar disorder and their healthy siblings: a preliminary study

    PubMed Central

    Bauer, Isabelle E.; Wu, Mon-Ju; Frazier, T.W.; Mwangi, Benson; Spiker, Danielle; Zunta-Soares, Giovana B.; Soares, Jair C.

    2016-01-01

    Background Cognitive deficits have been consistently reported in individuals with bipolar disorder (BD). The cognitive profile of siblings of individuals with BD is, however, less clearly established possibly due to the heterogeneity of neuropsychological measures used in previous studies. The aim of this exploratory study was to assess the cognitive function of siblings of individuals with BD and compare it with that of their first-degree relatives suffering with BD, and healthy controls (HC) using the Cambridge Neuropsychological Test Automated Battery (CANTAB) - a comprehensive and validated computerized cognitive battery. Methods We recruited 23 HC (33.52±10.29 years, 8 males), 27 individuals with BD (34.26±10.19 years, 9 males, 25 BDI, 1BDII and 1 BD-NOS), and 15 of their biologically related siblings (37.47±13.15 years, 4 males). Siblings had no current or lifetime history of mental disorders. Participants performed the CANTAB and completed questionnaires assessing mood and global functioning. Multivariate analyses compared CANTAB measures across the three participant groups. Results Individuals with BD and their siblings were less accurate in a task of sustained attention (Rapid Visual Processing) when compared to HC. Further, individuals with BD displayed pronounced deficits in affective processing (Affective Go/No-Go) compared to HC. There were no cognitive differences between siblings and individuals with BD. After correcting for current depressive symptoms, these results did not reach statistical significance. Conclusions Subthreshold depressive symptoms may be associated with reduced sustained attention in healthy siblings of BD patients. This preliminary result needs to be corroborated by large-scale, longitudinal studies assessing the relationship between cognition and mood in vulnerable individuals. PMID:27179338

  15. Deep reconditioning of batteries during DSCS 3 flight operations

    NASA Technical Reports Server (NTRS)

    Thierfelder, H. E.; Stearns, R. J.; Jones, P. W.

    1985-01-01

    Deep reconditioning of batteries is defined as discharge below the 1.0 volt/cell level to a value of about 1.0 volt/battery. This type of reconditioning was investigated for use on the Defense Satellite Communications System (DSCS) spacecraft, and has been used during the first year of orbital operation. Prior to launch of the spacecraft, the deep reconditioning was used during the battery life test, which has now complete fourteen eclipse periods. Reconditioning was performed prior to each eclipse period of the life test, and is scheduled to be used prior to each eclipse period in orbit. The battery data for discharge and recharge is presented for one of the life test reconditioning cycles, and for each of the three batteries during the reconditioning cycles between eclipse period no.1 and eclipse period no.2 in Earth orbit.

  16. Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.

    PubMed

    Staszewska, Anna; Zaki, Pearl; Lee, Joon

    2017-10-06

    Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious illness. ©Anna Staszewska, Pearl Zaki, Joon Lee. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 06.10.2017.

  17. Sensitivity of the Halstead and Wechsler Test Batteries to brain damage: Evidence from Reitan's original validation sample.

    PubMed

    Loring, David W; Larrabee, Glenn J

    2006-06-01

    The Halstead-Reitan Battery has been instrumental in the development of neuropsychological practice in the United States. Although Reitan administered both the Wechsler-Bellevue Intelligence Scale and Halstead's test battery when evaluating Halstead's theory of biologic intelligence, the relative sensitivity of each test battery to brain damage continues to be an area of controversy. Because Reitan did not perform direct parametric analysis to contrast group performances, we reanalyze Reitan's original validation data from both Halstead (Reitan, 1955) and Wechsler batteries (Reitan, 1959a) and calculate effect sizes and probability levels using traditional parametric approaches. Eight of the 10 tests comprising Halstead's original Impairment Index, as well as the Impairment Index itself, statistically differentiated patients with unequivocal brain damage from controls. In addition, 13 of 14 Wechsler measures including Full-Scale IQ also differed statistically between groups (Brain Damage Full-Scale IQ = 96.2; Control Group Full Scale IQ = 112.6). We suggest that differences in the statistical properties of each battery (e.g., raw scores vs. standardized scores) likely contribute to classification characteristics including test sensitivity and specificity.

  18. Comparison of Battery Life Across Real-World Automotive Drive-Cycles (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, K.; Earleywine, M.; Wood, E.

    2011-11-01

    Laboratories run around-the-clock aging tests to try to understand as quickly as possible how long new Li-ion battery designs will last under certain duty cycles. These tests may include factors such as duty cycles, climate, battery power profiles, and battery stress statistics. Such tests are generally accelerated and do not consider possible dwell time at high temperatures and states-of-charge. Battery life-predictive models provide guidance as to how long Li-ion batteries may last under real-world electric-drive vehicle applications. Worst-case aging scenarios are extracted from hundreds of real-world duty cycles developed from vehicle travel surveys. Vehicles examined included PHEV10 and PHEV40 EDVsmore » under fixed (28 degrees C), limited cooling (forced ambient temperature), and aggressive cooling (20 degrees C chilled liquid) scenarios using either nightly charging or opportunity charging. The results show that battery life expectancy is 7.8 - 13.2 years for the PHEV10 using a nightly charge in Phoenix, AZ (hot climate), and that the 'aggressive' cooling scenario can extend battery life by 1-3 years, while the 'limited' cooling scenario shortens battery life by 1-2 years. Frequent (opportunity) charging can reduce battery life by 1 year for the PHEV10, while frequent charging can extend battery life by one-half year.« less

  19. Effect of trait anxiety on cognitive test performance in adolescents with and without attention-deficit/hyperactivity disorder.

    PubMed

    Ruf, Barbara M; Bessette, Katie L; Pearlson, Godfrey D; Stevens, Michael C

    2017-06-01

    Attention-deficit/hyperactivity disorder (ADHD) and anxiety are frequently comorbid disorders associated with different types of abnormal performance on neuropsychological tests. Although some studies have shown that comorbid anxiety alters ADHD test performance, results inconsistently show both improvements and worsening of different abilities, with failures to replicate across different anxiety disorders. Alternatively, trait anxiety may reflect a more stable influence on ADHD test performance than various diagnosable anxiety disorders. To better understand the possible enhancing or deleterious effects of anxiety on ADHD cognitive impairments, this study examined the effect of individual differences in trait anxiety measured by the Multidimensional Anxiety Scale for Children (MASC) on a battery of computerized, rapid-performance tests measuring attention and impulsivity-related performance in 98 Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition (DSM-IV) Combined-Subtype ADHD adolescents and 123 healthy controls. It was hypothesized that trait anxiety would attenuate response inhibition and attention deficits in ADHD. ADHD-diagnosed adolescents with higher trait anxiety performed better on indices of sustained attention, reaction time, and motor variability, and had altered overall test-performance strategy, while response inhibition was affected in both ADHD and non-ADHD. This study provides the first evidence that pathological levels of anxiety are not needed to see differences in ADHD neuropsychological test performance. Instead, mildly elevated trait anxiety confers a protective influence by reducing the degree of impairment seen in ADHD. These findings suggest that better performing ADHD adolescents might have optimized levels of cortical arousal, and raise new questions about how best to identify the neurobiological substrates responsible for the beneficial effects.

  20. Solar photovoltaic charging of lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Gibson, Thomas L.; Kelly, Nelson A.

    Solar photovoltaic (PV) charging of batteries was tested by using high efficiency crystalline and amorphous silicon PV modules to recharge lithium-ion battery modules. This testing was performed as a proof of concept for solar PV charging of batteries for electrically powered vehicles. The iron phosphate type lithium-ion batteries were safely charged to their maximum capacity and the thermal hazards associated with overcharging were avoided by the self-regulating design of the solar charging system. The solar energy to battery charge conversion efficiency reached 14.5%, including a PV system efficiency of nearly 15%, and a battery charging efficiency of approximately 100%. This high system efficiency was achieved by directly charging the battery from the PV system with no intervening electronics, and matching the PV maximum power point voltage to the battery charging voltage at the desired maximum state of charge for the battery. It is envisioned that individual homeowners could charge electric and extended-range electric vehicles from residential, roof-mounted solar arrays, and thus power their daily commuting with clean, renewable solar energy.

Top