Sample records for computerized tomographic angiography

  1. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.

  2. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    PubMed

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  3. Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

    PubMed Central

    Chakravarthy, Murali; Sunilkumar, Gubbihalli; Pargaonkar, Sumant; Hosur, Rajathadri; Harivelam, Chidananda; Kavaraganahalli, Deepak; Srinivasan, Pradeep

    2015-01-01

    Objective: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. Methods: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. Results: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). Conclusion: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. PMID:25849686

  4. A cost-utility analysis of the use of preoperative computed tomographic angiography in abdomen-based perforator flap breast reconstruction.

    PubMed

    Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei

    2015-04-01

    Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.

  5. Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelines

    PubMed Central

    Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C

    2014-01-01

    Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706

  6. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke

    PubMed Central

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M.; Adams, Matthew E.; Yan, Bernard; Demchuk, Andrew M.; Farrall, Andrew J.; Sellar, Robin J.; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I.; Sandercock, Peter A.G.

    2017-01-01

    Background and Purpose— Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. Methods— We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. Results— In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18–3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58–1.35; P=0.566) arterial obstruction (P for interaction 0.017). Conclusions— Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. Clinical Trial Registration— URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. PMID:28008093

  7. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke.

    PubMed

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M; Adams, Matthew E; Yan, Bernard; Demchuk, Andrew M; Farrall, Andrew J; Sellar, Robin J; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I; Sandercock, Peter A G; Wardlaw, Joanna M

    2017-02-01

    Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18-3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58-1.35; P=0.566) arterial obstruction (P for interaction 0.017). Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. © 2016 The Authors.

  8. Right Cardiac Chambers Involvement by a Malignant Testicular Germ Cell Tumor: An Imaging-pathologic Correlation.

    PubMed

    do Nascimento, Felipe Barjud Pereira; Albieri, Lilian; Bento Dos Santos, Glaucia Aparecida; Dolhnikoff, Marisa

    2016-07-01

    The cardiac chamber's involvement with neoplastic embolism has been rarely reported; it is mostly associated with gastric, breast, lung, liver, and prostate cancers, and usually affects the pulmonary arteries. This paper reports a case of a 31-year-old man with a malignant testicular germ cell tumor who presented with multiple episodes of pulmonary thromboembolism and died of sudden respiratory failure 1 year after the initial diagnosis. Death was attributed to massive pulmonary embolism and pulmonary infarction associated with a neoplastic thrombus that extended from the gonadal veins to pulmonary arteries. A postmortem computerized tomographic angiography and autopsy confirmed this finding. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Successful Transarterial Embolization of a Posttraumatic Fistula Between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus: A Case Report.

    PubMed

    Jinbo, Yin; Jun, Liu; Kejie, Mou; Zheng, Zhou

    2015-01-01

    Posterior communicating artery (PCoA) aneurysm-cavernous sinus fistulae are an extremely rare complication of head injury . The treatment of PCoA aneurysm-cavernous sinus fistulae has not been well described. A 27-year-old man was admitted with a retroocular bruit and blurred vision of the left eye seven months after a severe head injury. We report the angiographic appearance of a posterior communicating artery (PCoA) aneurysm with a fistula to the cavernous sinus. This injury had been previously misinterpreted to be a PCoA aneurysm by computerized tomographic angiography (CTA). The patient was successfully treated with coils and Onyx of a fistula between the PCoA aneurysm and cavernous sinus.

  10. Intravenous volume tomographic pulmonary angiography imaging

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.

  11. ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals

    DOE R&D Accomplishments Database

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.

  12. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coupe, Nicholas J., E-mail: optimus2050@hotmail.com; Ling, Lynn; Cowling, Mark G.

    2009-07-15

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was alsomore » not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.« less

  13. Computed Tomographic Blend Sign Is Associated With Computed Tomographic Angiography Spot Sign and Predicts Secondary Neurological Deterioration After Intracerebral Hemorrhage.

    PubMed

    Sporns, Peter B; Schwake, Michael; Schmidt, Rene; Kemmling, André; Minnerup, Jens; Schwindt, Wolfram; Cnyrim, Christian; Zoubi, Tarek; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta

    2017-01-01

    Significant early hematoma growth in patients with intracerebral hemorrhage is an independent predictor of poor functional outcome. Recently, the novel blend sign (BS) has been introduced as a new imaging sign for predicting hematoma growth in noncontrast computed tomography. Another parameter predicting increasing hematoma size is the well-established spot sign (SS) visible in computed tomographic angiography. We, therefore, aimed to clarify the association between established SS and novel BS and their values predicting a secondary neurological deterioration. Retrospective study inclusion criteria were (1) spontaneous intracerebral hemorrhage confirmed on noncontrast computed tomography and (2) noncontrast computed tomography and computed tomographic angiography performed on admission within 6 hours after onset of symptoms. We defined a binary outcome (secondary neurological deterioration versus no secondary deterioration). As secondary neurological deterioration, we defined (1) early hemicraniectomy under standardized criteria or (2) secondary decrease of Glasgow Coma Scale of >3 points, both within the first 48 hours after symptom onset. Of 182 patients with spontaneous intracerebral hemorrhage, 37 (20.3%) presented with BS and 39 (21.4%) with SS. Of the 81 patients with secondary deterioration, 31 (38.3%) had BS and SS on admission. Multivariable logistic regression analysis identified hematoma volume (odds ratio, 1.07 per mL; P≤0.001), intraventricular hemorrhage (odds ratio, 3.08; P=0.008), and the presence of BS (odds ratio, 11.47; P≤0.001) as independent predictors of neurological deterioration. The BS, which is obtainable in noncontrast computed tomography, shows a high correlation with the computed tomographic angiography SS and is a reliable predictor of secondary neurological deterioration after spontaneous intracerebral hemorrhage. © 2016 American Heart Association, Inc.

  14. D-dimer threshold increase with pretest probability unlikely for pulmonary embolism to decrease unnecessary computerized tomographic pulmonary angiography

    PubMed Central

    Hogg, Melanie M.; Courtney, D. Mark; Miller, Chadwick D.; Jones, Alan E.; Smithline, Howard A

    2012-01-01

    Background Increasing the threshold to define a positive D-dimer could reduce unnecessary computed tomographic pulmonary angiography (CTPA) for suspected PE but might increase rates of missed PE and missed pneumonia, the most common nonthromboembolic diagnosis seen on CTPA. Objective Measure the effect of doubling the standard D-dimer threshold for “PE unlikely” Revised Geneva (RGS) or Wells’ scores on the exclusion rate, frequency and size of missed PE and missed pneumonia. Methods Patients evaluated for suspected PE with 64-channel CTPA were prospectively enrolled from EDs and inpatient units of four hospitals. Pretest probability data were collected in real time and the D-dimer was measured in a central laboratory. Criterion standard was CPTA interpretation by two independent radiologists combined with clinical outcome at 30 days. Results Of 678 patients enrolled, 126 (19%) were PE+ and 93 (14%) had pneumonia. Use of either Wells≤4 or RGS≤6 produced similar results. For example, with RGS≤6 and standard threshold (<500 ng/mL), D-dimer was negative in 110/678 (16%), and 4/110 were PE+ (posterior probability 3.8%), and 9/110 (8.2%) had pneumonia. With RGS≤6 and a threshold <1000 ng/mL, D-dimer was negative in 208/678 (31%) and 11/208 (5.3%) were PE+, but 10/11 missed PEs were subsegmental, and none had concomitant DVT. Pneumonia was found in 12/208 (5.4%) with RGS≤6 and D-dimer<1000 ng/mL. Conclusions Doubling the threshold for a positive D-dimer with a PE unlikely pretest probability could reduce CTPA scanning with a slightly increased risk of missed isolated subsegmental PE, and no increase in rate of missed pneumonia. PMID:22284935

  15. Prognostic value of coronary computed tomographic angiography findings in asymptomatic individuals: a 6-year follow-up from the prospective multicentre international CONFIRM study.

    PubMed

    Cho, Iksung; Al'Aref, Subhi J; Berger, Adam; Ó Hartaigh, Bríain; Gransar, Heidi; Valenti, Valentina; Lin, Fay Y; Achenbach, Stephan; Berman, Daniel S; Budoff, Matthew J; Callister, Tracy Q; Al-Mallah, Mouaz H; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Villines, Todd C; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J; Kaufmann, Philipp A; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Chang, Hyuk-Jae; Min, James K

    2018-03-14

    The long-term prognostic benefit of coronary computed tomographic angiography (CCTA) findings of coronary artery disease (CAD) in asymptomatic populations is unknown. From the prospective multicentre international CONFIRM long-term study, we evaluated asymptomatic subjects without known CAD who underwent both coronary artery calcium scoring (CACS) and CCTA (n = 1226). Coronary computed tomographic angiography findings included the severity of coronary artery stenosis, plaque composition, and coronary segment location. Using the C-statistic and likelihood ratio tests, we evaluated the incremental prognostic utility of CCTA findings over a base model that included a panel of traditional risk factors (RFs) as well as CACS to predict long-term all-cause mortality. During a mean follow-up of 5.9 ± 1.2 years, 78 deaths occurred. Compared with the traditional RF alone (C-statistic 0.64), CCTA findings including coronary stenosis severity, plaque composition, and coronary segment location demonstrated improved incremental prognostic utility beyond traditional RF alone (C-statistics range 0.71-0.73, all P < 0.05; incremental χ2 range 20.7-25.5, all P < 0.001). However, no added prognostic benefit was offered by CCTA findings when added to a base model containing both traditional RF and CACS (C-statistics P > 0.05, for all). Coronary computed tomographic angiography improved prognostication of 6-year all-cause mortality beyond a set of conventional RF alone, although, no further incremental value was offered by CCTA when CCTA findings were added to a model incorporating RF and CACS.

  16. DETECTION OF NONEXUDATIVE CHOROIDAL NEOVASCULARIZATION IN AGE-RELATED MACULAR DEGENERATION WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Palejwala, Neal V; Jia, Yali; Gao, Simon S; Liu, Liang; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Wilson, David J; Huang, David; Bailey, Steven T

    2015-11-01

    To evaluate eyes with age-related macular degeneration and high-risk characteristics for choroidal neovascularization (CNV) with optical coherence tomographic (OCT) angiography to determine whether earlier detection of CNV is possible. Eyes with drusen, pigmentary changes, and with CNV in the fellow eye were scanned with a 70-kHz spectral domain OCT system (Optovue RTVue-XR Avanti). The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to distinguish blood flow from static tissue. Two masked graders reviewed scans for CNV, defined as flow in the outer retinal/sub-RPE slab. Choroidal neovascularization flow area repeatability and between-grader reproducibility were calculated. Of 32 eyes, 2 (6%) were found to have Type 1 CNV with OCT angiography. The lesions were not associated with leakage on fluorescein angiography or fluid on OCT. One case was followed for 8 months without treatment, and the CNV flow area enlarged slightly without fluid buildup on OCT or vision loss. Between-grader reproducibility of the CNV flow area was 9.4% (coefficient of variation) and within-visit repeatability was 5.2% (pooled coefficient of variation). Optical coherence tomographic angiography can detect the presence of nonexudative CNV, lesions difficult to identify with fluorescein angiography and OCT. Further study is needed to understand the significance and natural history of these lesions.

  17. The Supraclavicular Artery Perforator Flap: A Comparative Study of Imaging Techniques Used in Preoperative Mapping.

    PubMed

    Sheriff, Hemin Oathman; Mahmood, Kawa Abdullah; Hamawandi, Nzar; Mirza, Aram Jamal; Hawas, Jawad; Moreno, Esther Granell; Clavero, Juan Antonio; Hankins, Christopher; Masia, Jaume

    2018-05-18

     The supraclavicular artery flap is an excellent flap for head and neck reconstruction. The aim of this study is to assess imaging techniques to define the precise vascular boundaries of this flap.  Six imaging techniques were used for supraclavicular artery mapping in 65 cases; handheld Doppler, triplex ultrasound, computed tomography angiography, magnetic resonance angiography, digital subtraction angiography, and indocyanine green angiography. We checked the site of the perforators, the course of a supraclavicular artery, and anatomical mapping of the supraclavicular artery.  Handheld Doppler identified perforators' sites in 80% of the cases but showed no results for the course of the vessel. Triplex ultrasound identified the site of perforators in 52.9%, and partial mapping of the course of a supraclavicular artery in 64.7% of the cases. Computerized tomography angiography showed the site of perforators in 60%, and the course of supraclavicular artery completely in 45%, and partially in an additional 30%of the cases examined. Magnetic resonance angiography showed negative results for all parameters. Digital subtraction angiography showed the partial course of a supraclavicular artery in 62.5%, but showed no perforators. Indocyanine green angiography showed the site of perforators in 60% and a partial course of supraclavicular artery distal to perforators in 60%.Anatomical mapping of the vessel was possible with computerized tomography angiogram completely in 45%, and partially in 30%, and was also possible with indocyanine green angiography partially in 60%.  Computerized tomography angiography showed best results in the mapping of the supraclavicular artery, but with an inability to define the perforator perfusion territories, and also with risks of irradiation, while indocyanine green angiography is a good alternative as it could precisely map the superficial course of the artery and angiosomes, with no radiation exposure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    PubMed

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Carotid Angioplasty and Stenting

    MedlinePlus

    ... and of the blood flow to the brain. Magnetic resonance angiography (MRA) or computerized tomography angiography (CTA). ... vessels by using either radiofrequency waves in a magnetic field or by using X-rays with contrast ...

  20. The Use of Chest Computed Tomographic Angiography in Blunt Trauma Pediatric Population.

    PubMed

    Hasadia, Rabea; DuBose, Joseph; Peleg, Kobi; Stephenson, Jacob; Givon, Adi; Kessel, Boris

    2018-02-05

    Blunt chest trauma in children is common. Although rare, associated major thoracic vascular injuries (TVIs) are lethal potential sequelae of these mechanisms. The preferred study for definitive diagnosis of TVI in stable patients is computed tomographic angiography imaging of the chest. This imaging modality is, however, associated with high doses of ionizing radiation that represent significant carcinogenic risk for pediatric patients. The aim of the present investigation was to define the incidence of TVI among blunt pediatric trauma patients in an effort to better elucidate the usefulness of computed tomographic angiography use in this population. A retrospective cohort study was conducted including all blunt pediatric (age < 14 y) trauma victims registered in Israeli National Trauma Registry maintained by Gertner Institute for Epidemiology and Health Policy Research between the years 1997 and 2015. Data collected included age, sex, mechanism of injury, Glasgow Coma Scale, Injury Severity Score, and incidence of chest named vessel injuries. Statistical analysis was performed using SAS statistical software version 9.2 (SAS Institute Inc, Cary, NC). Among 433,325 blunt trauma victims, 119,821patients were younger than 14 years. Twelve (0.0001%, 12/119821) of these children were diagnosed with TVI. The most common mechanism in this group was pedestrian hit by a car. Mortality was 41.7% (5/12). Thoracic vascular injury is exceptionally rare among pediatric blunt trauma victims but does contribute to the high morbidity and mortality seen with blunt chest trauma. Computed tomographic angiography, with its associated radiation exposure risk, should not be used as a standard tool after trauma in injured children. Clinical protocols are needed in this population to minimize radiation risk while allowing prompt identification of life-threatening injuries.

  1. Computerized tomography using video recorded fluoroscopic images

    NASA Technical Reports Server (NTRS)

    Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.

    1975-01-01

    A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

  2. Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.

    PubMed

    Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung

    2015-11-01

    With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.

  3. Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.

    PubMed

    Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng

    2018-05-01

    The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.

  4. Lumbar artery perforators: an anatomical study based on computed tomographic angiography imaging.

    PubMed

    Sommeling, Casper Emile; Colebunders, Britt; Pardon, Heleen E; Stillaert, Filip B; Blondeel, Phillip N; van Landuyt, Koenraad

    2017-08-01

    The free lumbar artery perforator flap has recently been introduced as a potentially valuable option for autologous breast reconstruction in a subset of patients. Up to date, few anatomical studies, exploring the lumbar region as a donor site for perforator- based flaps, have been conducted. An anatomical study of the position of the dominant lumbar artery perforator was performed, using the preoperative computed tomographic angiography images of 24 autologous breast reconstruction patients. In total, 61 dominant perforators were determined, 28 on the left and 33 on the right side. A radiologist defined the position of the perforator as coordinates in an xy-grid. Dominant perforators were shown to originate from the lumbar arteries at the level of lumbar vertebrae three or four. Remarkably, approximately 85% of these lumbar artery perforators enter the skin at 7-10 cm lateral from the midline (mean left 8.6 cm, right 8.2 cm). This study concludes a rather constant position of the dominant perforator. Therefore, preoperative-computed tomographic angiography is not always essential to find this perforator and Doppler ultrasound could be considered as an alternative, thereby carefully assessing all advantages and disadvantages inherent to either of these imaging methods.

  5. Nuclear medicine in clinical neurology: an update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldendorf, W.H.

    1981-01-01

    Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less

  6. Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls

    PubMed Central

    Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James

    2013-01-01

    Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972

  7. Computerized tomography calibrator

    NASA Technical Reports Server (NTRS)

    Engel, Herbert P. (Inventor)

    1991-01-01

    A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.

  8. Carotid-bulb atypical fibromuscular dysplasia in young Afro-Caribbean patients with stroke.

    PubMed

    Joux, Julien; Chausson, Nicolas; Jeannin, Séverine; Saint-Vil, Martine; Mejdoubi, Mehdi; Hennequin, Jean-Luc; Deschamps, Lydia; Smadja, Didier; Olindo, Stéphane

    2014-12-01

    An atypical form of fibromuscular dysplasia located in the internal carotid-bulb (CaFMD) is thought to be uncommon and is poorly described as a cause of ischemic stroke in the young. This study aimed to obtain a better description of CaFMD in Afro-Caribbean population, who could be particularly affected by it. This study included consecutive patients <55 years consulting at Fort-de-France University Hospital Stroke Center (Martinique, FWI) found to have CaFMD as the only cause after a comprehensive work-up. CaFMD was diagnosed when computed tomographic angiography showed a bulbar spur without calcification. Twenty-five patients with stroke and CaFMD were identified. Computed tomographic angiography showed 2 CaFMD patterns: a thin (n=15) or thick (n=10) spur. Three patients initial computed tomographic angiography images showed a mural thrombus overlying the CaFMD. CaFMD was surgically removed from 7 of 25 and 20 of 25 patients who received antiplatelet therapy; after mean follow-up of 25.3±19.5 months, their respective recurrence rates were 0% and 30%. CaFMD could be a common condition in young Afro-Caribbeans with carotid-territory ischemic stroke. Recurrences were frequent under antiplatelet treatment, while surgical CaFMD removal seemed more effective. © 2014 American Heart Association, Inc.

  9. Preoperative evaluation of hilar vessel anatomy with 3-D computerized tomography in living kidney donors.

    PubMed

    Tombul, S T; Aki, F T; Gunay, M; Inci, K; Hazirolan, T; Karcaaltincaba, M; Erkan, I; Bakkaloglu, A; Yasavul, U; Bakkaloglu, M

    2008-01-01

    Digital subtract angiography is the gold standard for anatomic assessment of renal vasculature for living renal donors. However, multidetector-row computerized tomography (MDCT) is less invasive than digital subtract angiography and provides information of kidney stones and other intra-abdominal organs. In this study, preoperative MDCT angiography results were compared with the peroperative findings to evaluate the accuracy of MDCT for the evaluation of renal anatomy. From December 2002 to May 2007, all 60 consecutive living kidney donors were evaluated with MDCT angiography preoperatively. We reported the number and origin of renal arteries, presence of early branching arteries, and any intrinsic renal artery disease. Renal venous anatomy was evaluated for the presence of accessory, retroaortic, and circumaortic veins using venous phase axial images. The calyces and ureters were assessed with delayed topograms. The results of the MDCT angiography were compared with the peroperative findings. A total of 67 renal arteries were seen peroperatively in 60 renal units. Preoperative MDCT angiography detected 64 of them. The two arteries not detected by MDCT had diameters less than 3 mm. Anatomic variations were present in nine veins, five of which were detected by CT angiography. Sensitivity of MDCT angiography for arteries and veins was 95% and 93%, respectively. Positive predictive values were 100% for both arteries and veins. MDCT angiography offers a less invasive, rapid, and accurate preoperative investigation modality for vascular anatomy in living kidney donors. It also provides sufficient information about extrarenal anatomy important for donor surgery.

  10. Effects of Multi-Electrode Renal Denervation on Insulin Sensitivity and Glucose Metabolism in a Canine Model of Type 2 Diabetes Mellitus.

    PubMed

    Pan, Tao; Guo, Jin-He; Ling, Long; Qian, Yue; Dong, Yong-Hua; Yin, Hua-Qing; Zhu, Hai-Dong; Teng, Gao-Jun

    2018-05-01

    To evaluate the effects of multi-electrode catheter-based renal denervation (RDN) on insulin sensitivity and glucose metabolism in a type 2 diabetes mellitus (T2DM) canine model. Thirty-three dogs were divided equally into 3 groups: bilateral renal denervation (BRDN) group, left renal denervation (LRDN) group, and sham operation (SHAM) group. Body weight and blood biochemistry were measured at baseline, 20 weeks, and 32 weeks, and renal angiography and computerized tomographic (CT) angiography were determined before the procedure and 1 month, 2 months, and 3 months after the procedure. Western blot was used to identify the activities of gluconeogenic enzymes and insulin-signaling proteins. Fasting plasma glucose (9.64 ± 1.57 mmol/L vs 5.12 ± 1.08 mmol/L; P < .0001), fasting insulin (16.19 ± 1.43 mIU/mL vs 5.07 ± 1.13 mIU/mL; P < .0001), and homeostasis-model assessment of insulin resistance (HOMA-IR; 6.95 ± 1.33 vs 1.15 ± 0.33; P < .0001) in the BRDN group had significantly decreased at the 3-month follow-up compared with the SHAM group. Western blot analyses showed that RDN suppressed the gluconeogenetic genes, modulated insulin action, and activated insulin receptors-AKT signaling cascade in the liver. CT angiography and histopathologic analyses did not show any dissection, aneurysm, thrombus, or rupture in any of the renal arteries. These findings identified that multi-electrode catheter-based RDN could effectively decrease gluconeogenesis and glycogenolysis, resulting in improvements in insulin sensitivity and glucose metabolism in a T2DM canine model. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  11. Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction

    PubMed Central

    Chae, Michael P.; Hunter-Smith, David J.

    2015-01-01

    Background The high incidence of breast cancer and growing number of breast cancer patients undergoing mastectomy has led to breast reconstruction becoming an important part of holistic treatment for these patients. In planning autologous reconstructions, preoperative assessment of donor site microvascular anatomy with advanced imaging modalities has assisted in the appropriate selection of flap donor site, individual perforators, and lead to an overall improvement in flap outcomes. In this review, we compare the accuracy of fluorescent angiography, computed tomographic angiography (CTA), and magnetic resonance angiography (MRA) and their impact on clinical outcomes. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE was undertaken. Results Fluorescent angiography is technically limited by its inability to evaluate deep-lying perforators and hence, it has a minimal role in the preoperative setting. However, it may be useful intraoperatively in evaluating microvascular anastomotic patency and the mastectomy skin perfusion. CTA is currently widely considered the standard, due to its high accuracy and reliability. Multiple studies have demonstrated its ability to improve clinical outcomes, such as operative length and flap complications. However, concerns surrounding exposure to radiation and nephrotoxic contrast agents exist. MRA has been explored, however despite recent advances, the image quality of MRA is considered inferior to CTA. Conclusions Preoperative imaging is an essential component in planning autologous breast reconstruction. Fluorescent angiography presents minimal role as a preoperative imaging modality, but may be a useful intraoperative adjunct to assess the anastomosis and the mastectomy skin perfusion. Currently, CTA is the gold standard preoperatively. MRA has a role, particularly for women of younger age, iodine allergy, and renal impairment. PMID:26005648

  12. Image intensifier-based volume tomographic angiography imaging system: system evaluation

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Wang, Xiaohui; Shen, Jianjun; Conover, David L.

    1995-05-01

    An image intensifier-based rotational volume tomographic angiography imaging system has been constructed. The system consists of an x-ray tube and an image intensifier that are separately mounted on a gantry. This system uses an image intensifier coupled to a TV camera as a two-dimensional detector so that a set of two-dimensional projections can be acquired for a direct three-dimensional reconstruction (3D). This system has been evaluated with two phantoms: a vascular phantom and a monkey head cadaver. One hundred eighty projections of each phantom were acquired with the system. A set of three-dimensional images were directly reconstructed from the projection data. The experimental results indicate that good imaging quality can be obtained with this system.

  13. Can macrocirculation changes predict nonhealing diabetic foot ulcers?

    PubMed

    Lee, Ye-Na; Kim, Hyon-Surk; Kang, Jeong-A; Han, Seung-Kyu

    2014-01-01

    Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.

  14. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study.

    PubMed

    Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard

    2015-12-14

    In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  15. Relationship of Hypertension to Coronary Atherosclerosis and Cardiac Events in Patients With Coronary Computed Tomographic Angiography.

    PubMed

    Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S

    2017-08-01

    Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.

  16. Noninvasive coronary artery angiography using electron beam computed tomography

    NASA Astrophysics Data System (ADS)

    Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II

    1996-04-01

    Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.

  17. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard.

    PubMed

    Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy

    2009-10-15

    Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

  18. Gadolinium-enhanced computed tomographic angiography: current status.

    PubMed

    Rosioreanu, Alex; Alberico, Ronald A; Litwin, Alan; Hon, Man; Grossman, Zachary D; Katz, Douglas S

    2005-01-01

    This article reviews the research to date, as well as our clinical experience from two institutions, on gadolinium-enhanced computed tomographic angiography (gCTA) for imaging the body. gCTA may be an appropriate examination for the small percentage of patients who would benefit from noninvasive vascular imaging, but who have contraindications to both iodinated contrast and magnetic resonance imaging. gCTA is more expensive than CTA with iodinated contrast, due to the dose of gadolinium administered, and gCTA has limitations compared with CTA with iodinated contrast, in that parenchymal organs are not optimally enhanced at doses of 0.5 mmol/kg or lower. However, in our experience, gCTA has been a very useful problem-solving examination in carefully selected patients. With the advent of 16-64 detector CT, in combination with bolus tracking, we believe that the overall dose of gadolinium needed for diagnostic CTA examinations, while relatively high, can be safely administered.

  19. Computed tomographic angiography in stroke imaging: fundamental principles, pathologic findings, and common pitfalls.

    PubMed

    Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R

    2006-06-01

    The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.

  20. Corkscrew basilar artery as an incidental finding on neuroimaging.

    PubMed

    Moser, Franklin G; Sarnat, Harvey B; Maya, Marcel M; Menkes, John H

    2007-11-01

    We report on an incidental finding of a markedly tortuous basilar artery in a 6-year-old child. The child underwent a computed tomography scan for minor head trauma, and a basilar artery abnormality was discovered, i.e., a markedly tortuous basilar artery without any other congenital anomalies or syndromes. After an exhaustive workup including computed tomography, magnetic resonance imaging, magnetic resonance angiography, computed tomographic angiography, and genetic tests for associated genetic syndromes, no intervention was deemed necessary. The embryonic etiology and clinical implications are discussed.

  1. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury

    PubMed Central

    Easley, R. Blaine; Mulreany, Daniel G.; Lancaster, Christopher T.; Custer, Jason W.; Fernandez-Bustamante, Ana; Colantuoni, Elizabeth; Simon, Brett A.

    2009-01-01

    Background Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. We hypothesize that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. Methods Anesthetized, mechanically ventilated canines were instrumented with PiCCO® (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computerized tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. Results Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly following endotoxin administration. Computerized tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. Conclusions The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computerized tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW. PMID:19809280

  2. Association of Brachial-Ankle Pulse Wave Velocity with Asymptomatic Intracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qain, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-08-01

    Intracranial arterial stenosis is a common cause of ischemic stroke in Asians. We therefore sought to explore the relationship of brachial-ankle pulse wave velocity and intracranial arterial stenosis in 834 stroke-free hypertensive patients. Intracranial arterial stenosis was evaluated through computerized tomographic angiography. Brachial-ankle pulse wave velocity was measured by an automated cuff device. The top decile of brachial-ankle pulse wave velocity was significantly associated with intracranial arterial stenosis (P = .027, odds ratio = 1.82; 95% confidence interval: 1.07-3.10). The patients with the top decile of brachial-ankle pulse wave velocity showed 56% higher risk for the presence of intracranial arterial stenosis to the whole population, which was more significant in patients younger than 65 years old. We also found that brachial-ankle pulse wave velocity related to both intracranial arterial stenosis and homocysteine. Our study showed the association of brachial-ankle pulse wave velocity with asymptomatic intracranial arterial stenosis in hypertension patients, especially in relative younger subjects. Brachial-ankle pulse wave velocity might be a relatively simple and repeatable measurement to detect hypertension patients in high risk of intracranial arterial stenosis. Copyright © 2016. Published by Elsevier Inc.

  3. Relationship between pseudoaneurysm formation and biloma after successful transarterial embolization for severe hepatic injury: permanent embolization using stainless steel coils prevents pseudoaneurysm formation.

    PubMed

    Hagiwara, Akiyoshi; Tarui, Takehiko; Murata, Atsuo; Matsuda, Takeaki; Yamaguti, Yoshihiro; Shimazaki, Shuji

    2005-07-01

    The purpose of this study was to determine the association between bilomas and pseudoaneurysm complications after severe hepatic injury. Angiography was performed in patients with American Association for the Surgery of Trauma grade > or = III hepatic injury on contrast-enhanced computed tomographic scanning. When contrast extravasation was observed, transarterial embolization (TAE) was performed. After TAE, technetium-99m pyridoxyl-5-methyl-tryptophan cholescintigraphy was performed to detect the coexistence of bilomas. Follow-up angiography was performed when a biloma was detected. Eighty consecutive patients underwent angiography; after angiography, five patients died. The remaining 75 patients who underwent cholescintigraphy were included in this study. All 11 patients who had bilomas had angiographic evidence of contrast extravasation. The biloma frequency was higher in patients with grades IV and V injuries than in those with grade III injury (p = 0.024). Follow-up angiography revealed pseudoaneurysms in 7 of these 11 patients. All six patients in whom only gelatin sponge pledget injection was used to embolize had pseudoaneurysms. Among them, two patients had computed tomographic evidence of massive intra-abdominal fluid collection. In contrast, only one of five patients who received the combination of gelatin sponge pledget injection and stainless steel coils to permanently embolize injured arteries had a pseudoaneurysm. In this patient, the pseudoaneurysm was found in the peripheral part of the collateral vessels. All patients with pseudoaneurysms underwent repeat TAE and were discharged from the hospital uneventfully. In patients with high-grade hepatic injury and arterial bleeding who developed biloma, use of a gelatin sponge, an absorbable embolic material, is associated with a risk of pseudoaneurysm formation. Permanent arterial embolization using stainless steel coils is indicated to decrease this risk.

  4. 64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.

    PubMed

    Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum

    2011-01-01

    To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.

  5. Fractional Flow Reserve and Coronary Computed Tomographic Angiography: A Review and Critical Analysis.

    PubMed

    Hecht, Harvey S; Narula, Jagat; Fearon, William F

    2016-07-08

    Invasive fractional flow reserve (FFR) is now the gold standard for intervention. Noninvasive functional imaging analyses derived from coronary computed tomographic angiography (CTA) offer alternatives for evaluating lesion-specific ischemia. CT-FFR, CT myocardial perfusion imaging, and transluminal attenuation gradient/corrected contrast opacification have been studied using invasive FFR as the gold standard. CT-FFR has demonstrated significant improvement in specificity and positive predictive value compared with CTA alone for predicting FFR of ≤0.80, as well as decreasing the frequency of nonobstructive invasive coronary angiography. High-risk plaque characteristics have also been strongly implicated in abnormal FFR. Myocardial computed tomographic perfusion is an alternative method with promising results; it involves more radiation and contrast. Transluminal attenuation gradient/corrected contrast opacification is more controversial and may be more related to vessel diameter than stenosis. Important considerations remain: (1) improvement of CTA quality to decrease unevaluable studies, (2) is the diagnostic accuracy of CT-FFR sufficient? (3) can CT-FFR guide intervention without invasive FFR confirmation? (4) what are the long-term outcomes of CT-FFR-guided treatment and how do they compare with other functional imaging-guided paradigms? (5) what degree of stenosis on CTA warrants CT-FFR? (6) how should high-risk plaque be incorporated into treatment decisions? (7) how will CT-FFR influence other functional imaging test utilization, and what will be the effect on the practice of cardiology? (8) will a workstation-based CT-FFR be mandatory? Rapid progress to date suggests that CTA-based lesion-specific ischemia will be the gatekeeper to the cardiac catheterization laboratory and will transform the world of intervention. © 2016 American Heart Association, Inc.

  6. Results of the National CT Colonography Trial: Questions and Answers

    Cancer.gov

    Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.

  7. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    PubMed

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  8. Multislice coronary computed tomographic angiography in emergency department presentations of unsuspected acute myocardial infarction.

    PubMed

    Hecht, Harvey S; Bhatti, Tandeep

    2009-01-01

    Coronary computed tomographic angiography (CCTA) is not indicated in the setting of acute myocardial infarction in the emergency department (ED). Nonetheless, acute coronary syndromes may have atypical presentations, and CCTA may be inadvertently performed in this setting. This study was designed to determine the frequency and characteristics of CCTA imaging of unsuspected acute myocardial infarction in the ED. All CCTAs performed in the ED at Lenox Hill Hospital were reviewed for clinical indications and subsequent course; patients with documented acute myocardial infarction were identified. Of the 500 CCTAs performed on ED patients in the Lenox Hill laboratory, 5 patients (1%) were imaged during the initial phase of an unsuspected acute myocardial infarction; in all cases the CCTAs were key to the diagnosis. The imaging characteristics were (1) total or subtotal occlusion and (2) transmural hypodensity in the infarct area. Although acute myocardial infarction on CCTA in ED patients is an infrequent event, proper and prompt recognition is critical for appropriate patient care, particularly as applications to the ED increase.

  9. Prospective radiographic followup after en bloc ligation of the renal hilum.

    PubMed

    White, Wesley M; Klein, Frederick A; Gash, Judson; Waters, W Bedford

    2007-11-01

    We determined the risk of arteriovenous fistula after en bloc ligation of the renal hilum. A prospective evaluation of all patients who underwent en bloc ligation of the renal hilum during nephrectomy for malignant disease was performed. Pertinent operative data were recorded and patients were followed for clinical evidence of arteriovenous fistula formation, including hypertension, abdominal bruit and new onset congestive heart failure. Patients with at least 12 months of followup underwent computerized tomographic arteriography to assess arteriovenous fistula formation. A total of 94 patients underwent en bloc renal hilar ligation during open (43) and laparoscopic (51) nephrectomy using a 45 mm titanium endovascular stapler. Of this cohort 11 patients were lost to followup and 3 died of disease. The remaining 80 patients were followed an average of 35.2 months with no clinical evidence of arteriovenous fistula formation. Specifically there was no statistically significant difference in preoperative and postoperative blood pressure (p = 0.18 and 0.62, respectively), no evidence of abdominal bruit on examination and no new onset congestive heart failure. A total of 32 had increased serum creatinine and, therefore, they were excluded from followup computerized tomographic arteriography. Eight patients had a followup of less than 1 year and they were not yet eligible for evaluation. In the 40 patients who underwent computerized tomographic arteriography no fistulas were noted. Based on clinical followup and prospective radiographic evaluation there appears to be a low risk of arteriovenous fistula formation after en bloc ligation of the renal hilum using a titanium endovascular stapler.

  10. Various origins of the duplicated middle cerebral artery.

    PubMed

    Tutar, Nihal Uslu; Töre, Hüseyin Gürkan; Kirbaş, Ismail; Tarhan, Nefise Cağla; Coşkun, Mehmet

    2008-10-01

    We describe the features of a duplicated middle cerebral artery identified by computed tomographic angiography that originates from a previously undefined origin, ie, from the petrous portion of the internal carotid artery. Recognition of this anomaly is important in patients with a possible aneurysm, which was not present in our patient.

  11. Dual origin of the right vertebral artery from the right common carotid and aberrant right subclavian arteries.

    PubMed

    Moshayedi, Pouria; Walker, Gregory B; Tavakoli, Sina; Desai, Shashvat M; Jadhav, Ashutosh P

    2018-07-01

    This report describes a case of duplicated origin of the right vertebral artery incidentally found in a young patient. Computed tomographic angiography and digital subtraction angiography showed a dominant branch derived from the right common carotid artery and an accessory branch that derived from the right subclavian artery, which aberrantly originated from the far left aortic arch, and adjoined the dominant branch at the C5 level. We discuss angiographic findings, clinical implications and embryological basis for this rare anomaly. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials

    PubMed Central

    Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia

    2018-01-01

    Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration PROSPERO registry no CRD42016049442. PMID:29467161

  13. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    PubMed

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  14. Tomographic digital subtraction angiography for lung perfusion estimation in rodents.

    PubMed

    Badea, Cristian T; Hedlund, Laurence W; De Lin, Ming; Mackel, Julie S Boslego; Samei, Ehsan; Johnson, G Allan

    2007-05-01

    In vivo measurements of perfusion present a challenge to existing small animal imaging techniques such as magnetic resonance microscopy, micro computed tomography, micro positron emission tomography, and microSPECT, due to combined requirements for high spatial and temporal resolution. We demonstrate the use of tomographic digital subtraction angiography (TDSA) for estimation of perfusion in small animals. TDSA augments conventional digital subtraction angiography (DSA) by providing three-dimensional spatial information using tomosynthesis algorithms. TDSA is based on the novel paradigm that the same time density curves can be reproduced in a number of consecutive injections of microL volumes of contrast at a series of different angles of rotation. The capabilities of TDSA are established in studies on lung perfusion in rats. Using an imaging system developed in-house, we acquired data for four-dimensional (4D) imaging with temporal resolution of 140 ms, in-plane spatial resolution of 100 microm, and slice thickness on the order of millimeters. Based on a structured experimental approach, we optimized TDSA imaging providing a good trade-off between slice thickness, the number of injections, contrast to noise, and immunity to artifacts. Both DSA and TDSA images were used to create parametric maps of perfusion. TDSA imaging has potential application in a number of areas where functional perfusion measurements in 4D can provide valuable insight into animal models of disease and response to therapeutics.

  15. Cost-effectiveness of follow-up of pulmonary nodules incidentally detected on cardiac computed tomographic angiography in patients with suspected coronary artery disease.

    PubMed

    Goehler, Alexander; McMahon, Pamela M; Lumish, Heidi S; Wu, Carol C; Munshi, Vidit; Gilmore, Michael; Chung, Jonathan H; Ghoshhajra, Brian B; Mark, Daniel; Truong, Quynh A; Gazelle, G Scott; Hoffmann, Udo

    2014-08-19

    Pulmonary nodules (PNs) are often detected incidentally during coronary computed tomographic (CT) angiography, which is increasingly being used to evaluate patients with chest pain symptoms. However, the efficiency of following up on incidentally detected PN is unknown. We determined demographic and clinical characteristics of stable symptomatic patients referred for coronary CT angiography in whom incidentally detected PNs warranted follow-up. A validated lung cancer simulation model was populated with data from these patients, and clinical and economic consequences of follow-up per Fleischner guidelines versus no follow-up were simulated. Of the 3665 patients referred for coronary CT angiography, 591 (16%) had PNs requiring follow-up. The mean age of patients with PNs was 59±10 years; 66% were male; 67% had ever smoked; and 21% had obstructive coronary artery disease. The projected overall lung cancer incidence was 5.8% in these patients, but the majority died of coronary artery disease (38%) and other causes (57%). Follow-up of PNs was associated with a 4.6% relative reduction in cumulative lung cancer mortality (absolute mortality: follow-up, 4.33% versus non-follow-up, 4.54%), more downstream testing (follow-up, 2.34 CTs per patient versus non-follow-up, 1.01 CTs per patient), and an average increase in quality-adjusted life of 7 days. Costs per quality-adjusted life-year gained were $154 700 to follow up the entire cohort and $129 800 per quality-adjusted life-year when only smokers were included. Follow-up of PNs incidentally detected in patients undergoing coronary CT angiography for chest pain evaluation is associated with a small reduction in lung cancer mortality. However, significant downstream testing contributes to limited efficiency, as demonstrated by a high cost per quality-adjusted life-year, especially in nonsmokers. © 2014 American Heart Association, Inc.

  16. Childhood Psychosis and Computed Tomographic Brain Scan Findings.

    ERIC Educational Resources Information Center

    Gillberg, Christopher; Svendsen, Pal

    1983-01-01

    Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)

  17. Diagnostic cardiology: Noninvasive imaging techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Come, P.C.

    1985-01-01

    This book contains 23 chapters. Some of the chapter titles are: The chest x-ray and cardiac series; Computed tomographic scanning of the heart, coronary arteries, and great vessels; Digital subtraction angiography in the assessment of cardiovascular disease; Magnetic resonance: technique and cardiac applications; Basics of radiation physics and instrumentation; and Nuclear imaging: the assessment of cardiac performance.

  18. Evaluation of hepatic arterial anatomy by multidetector computed tomographic angiography in living donor liver transplantation.

    PubMed

    Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit

    2016-06-01

    The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.

  19. Left main coronary artery stenosis: severity evaluation and implications for management.

    PubMed

    Habibi, Susan E; Shah, Rahman; Berzingi, Chalak O; Melchior, Ryan; Sumption, Kevin F; Jovin, Ion S

    2017-03-01

    The significant stenosis of the left main coronary artery is associated with poor outcomes and is considered a strong indication for revascularization. However, deciding whether the stenosis is significant can sometimes be challenging, especially when the degree of stenosis is intermediate, and can necessitate additional tests and imaging modalities. Areas covered: We did a literature search using keywords like 'left main', 'imaging', 'intravascular ultrasound', 'fractional flow reserve', 'computed tomographic angiography' and 'magnetic resonance imaging'. The most commonly used methods for better characterizing intermediate left main coronary stenoses are intravascular ultrasound and fractional flow reserve, while optical coherence tomography is the newer technique that provides better images, but for which not as much data is available. The noninvasive techniques are coronary computed tomographic angiography and, to a lesser degree, coronary magnetic resonance imaging. Expert commentary: Accurately determining the severity of left main coronary stenosis can mean the difference between a major intervention and conservative therapy. The reviewed newer imaging modalities give us greater confidence that patients with left main stenosis are assigned to the right treatment modality.

  20. Osmotic blood-brain barrier disruption. Computerized tomographic monitoring of chemotherapeutic agent delivery.

    PubMed Central

    Neuwelt, E A; Maravilla, K R; Frenkel, E P; Rapaport, S I; Hill, S A; Barnett, P A

    1979-01-01

    The present study describes a canine model of transient reversible blood-brain barrier disruption with hyperosmolar mannitol infusion into the internal carotid artery. Studies in this model show that osmotic blood-brain barrier disruption before intracarotid infusion of methotrexate results in markedly elevated (therapeutic) levels of drug in the ipsilateral cerebral hemisphere. Levels in the cerebrospinal fluid correlate poorly and inconsistently with brain levels. Computerized tomograms in this canine model provide a noninvasive monitor of the degree, time-course, and localization of osmotic blood-brain barrier disruption. Images PMID:457877

  1. Clinical outcomes after magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) for pulmonary embolism evaluation.

    PubMed

    Repplinger, Michael D; Nagle, Scott K; Harringa, John B; Broman, Aimee T; Lindholm, Christopher R; François, Christopher J; Grist, Thomas M; Reeder, Scott B; Schiebler, Mark L

    2018-05-10

    To compare patient outcomes following magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) ordered for suspected pulmonary embolism (PE). In this IRB-approved, single-center, retrospective, case-control study, we reviewed the medical records of all patients evaluated for PE with MRA during a 5-year period along with age- and sex-matched controls evaluated with CTA. Only the first instance of PE evaluation during the study period was included. After application of our exclusion criteria to both study arms, the analysis included 1173 subjects. The primary endpoint was major adverse PE-related event (MAPE), which we defined as major bleeding, venous thromboembolism, or death during the 6 months following the index imaging test (MRA or CTA), obtained through medical record review. Logistic regression, chi-square test for independence, and Fisher's exact test were used with a p < 0.05 threshold. The overall 6-month MAPE rate following MRA (5.4%) was lower than following CTA (13.6%, p < 0.01). Amongst outpatients, the MAPE rate was lower for MRA (3.7%) than for CTA (8.0%, p = 0.01). Accounting for age, sex, referral source, BMI, and Wells' score, patients were less likely to suffer MAPE than those who underwent CTA, with an odds ratio of 0.44 [0.24, 0.80]. Technical success rate did not differ significantly between MRA (92.6%) and CTA (90.5%) groups (p = 0.41). Within the inherent limitations of a retrospective case-controlled analysis, we observed that the rate of MAPE was lower (more favorable) for patients following pulmonary MRA for the primary evaluation of suspected PE than following CTA.

  2. Lower gastrointestinal bleeding: Role of 64-row computed tomographic angiography in diagnosis and therapeutic planning

    PubMed Central

    Ren, Jian-Zhuang; Zhang, Meng-Fan; Rong, Ai-Mei; Fang, Xiang-Jie; Zhang, Kai; Huang, Guo-Hao; Chen, Peng-Fei; Wang, Zhao-Yang; Duan, Xu-Hua; Han, Xin-Wei; Liu, Yan-Jie

    2015-01-01

    AIM: To determine the value of computed tomographic angiography (CTA) for diagnosis and therapeutic planning in lower gastrointestinal (GI) bleeding. METHODS: Sixty-three consecutive patients with acute lower GI bleeding underwent CTA before endovascular or surgical treatment. CTA was used to determine whether the lower GI bleeding was suitable for endovascular treatment, surgical resection, or conservative treatment in each patient. Treatment planning with CTA was compared with actual treatment decisions or endovascular or surgical treatment that had been carried out in each patient based on CTA findings. RESULTS: 64-row CTA detected active extravasation of contrast material in 57 patients and six patients had no demonstrable active bleeding, resulting in an accuracy of 90.5% in the detection of acute GI bleeding (57 of 63). In three of the six patients with no demonstrable active bleeding, active lower GI bleeding recurred within one week after CTA, and angiography revealed acute bleeding. The overall location-based accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the detection of GI bleeding by 64-row CTA were 98.8% (249 of 252), 95.0% (57 of 60), 100% (192 of 192), 100% (57 of 57), and 98.5% (192 of 195), respectively. Treatment planning was correctly established on the basis of 64-row CTA with an accuracy, sensitivity, specificity, PPV and NPV of 98.4% (248 of 252), 93.3% (56 of 60), 100% (192 of 192), 100% (56 of 56), and 97.5% (192 of 196), respectively, in a location-based evaluation. CONCLUSION: 64-row CTA is safe and effective in making decisions regarding treatment, without performing digital subtraction angiography or surgery, in the majority of patients with lower GI bleeding. PMID:25852291

  3. Contrast-enhanced magnetic resonance angiography for preoperative imaging of deep inferior epigastric artery perforator flaps: advantages and disadvantages compared with computed tomography angiography: a United Kingdom perspective.

    PubMed

    Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; McCulley, Stephen J

    2011-12-01

    The anatomy of the anterior abdominal wall is highly variable and leads to uncertainty when harvesting a deep inferior epigastric artery perforator flap. Presurgical imaging has been shown to reduce the operating time, as well as reduce the rates of flap and donor site complications. The importance of imaging of the venous system has also been recognized for reducing the risk of venous congestion. The modalities currently available for presurgical imaging include handheld Doppler ultrasound, duplex ultrasound, computed tomographic angiography (CTA), and contrast-enhanced magnetic resonance angiography (CE-MRA). Of these, the most promising are CTA and CE-MRA, and advantages and disadvantages exist for both modalities. In this article, we review the use of CE-MRA for preoperative flap imaging and report our experience with its use in deep inferior epigastric artery perforator flap harvest, as well as compare it with CTA. We also explore the future directions for presurgical flap imaging.

  4. Associations Between Collateral Status and Thrombus Characteristics and Their Impact in Anterior Circulation Stroke.

    PubMed

    Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M

    2018-02-01

    Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.

  5. Awake craniotomy for microsurgical obliteration of mycotic aneurysms: technical report of three cases.

    PubMed

    Lüders, Jürgen C; Steinmetz, Michael P; Mayberg, Marc R

    2005-01-01

    Infectious (mycotic) aneurysms that do not resolve with medical treatment require surgical obliteration, usually requiring sacrifice of the parent artery. In addition, patients with mycotic aneurysms frequently need subsequent cardiac valve repair, which often necessitates anticoagulation. Three cases of awake craniotomy for microsurgical clipping of mycotic aneurysms are presented. Awake minimally invasive craniotomy using frameless stereotactic guidance on the basis of computed tomographic angiography enables temporary occlusion of the parent artery with neurological assessment before obliteration of the aneurysm. A 56-year-old woman presented with progressively worsening mitral valve disease and a history of subacute bacterial endocarditis and subarachnoid hemorrhage 30 years previously. A cerebral angiogram revealed a 4-mm left middle cerebral artery (MCA) angular branch aneurysm, which required obliteration before mitral valve replacement. The second patient, a 64-year-old woman with a history of rheumatic fever, had an 8-mm right distal MCA aneurysm diagnosed in the setting of pulmonary abscess and worsening cardiac function as a result of mitral valve disease. The third patient, a 57-year-old man with a history of fevers, night sweats, and progressive mitral valve disease, had an enlarging left MCA angular branch aneurysm despite the administration of antibiotics. Because of their location on distal MCA branches, none of the aneurysms were amenable to preoperative test balloon occlusion. After undergoing stereotactic computed tomographic angiography with fiducial markers, the patients underwent a minimally invasive awake craniotomy with frameless stereotactic navigation. In all cases, the results of the neurological examination were unchanged during temporary parent artery occlusion and the aneurysms were successfully obliterated. Awake minimally invasive craniotomy for an infectious aneurysm located in eloquent brain enables awake testing before permanent clipping or vessel sacrifice. Combining frameless stereotactic navigation with computed tomographic angiography allowed us to perform the operation quickly through a small craniotomy with minimal exploration.

  6. Contralateral decubitus positioning enhances computed tomographic angiographic evaluation of pulmonary vasculature in a patient with a pulmonary arteriovenous malformation.

    PubMed

    Tafti, Bashir Akhavan; Berenji, Gholam R; Santiago, Silverio; Barack, Bruce M

    2012-11-01

    Computed tomographic pulmonary angiography has become the diagnostic procedure of choice in patients suspected of having a pulmonary embolus. However, intrapulmonary shunting of blood in a variety of pathologic conditions can cause suboptimal opacification of the pulmonary arterial circulation and result in a suboptimal or even nondiagnostic study. Radiologists should be aware of these conditions and be familiar with positioning techniques to minimize such shunting. We report a patient suspected of having pulmonary embolism, in whom a preexisting unilateral arteriovenous malformation prevented adequate evaluation of the pulmonary circulation. Positioning the patient in the contralateral decubitus position significantly enhanced image quality.

  7. CMT for biomedical and other applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spanne, P.

    This session includes two presentations describing applications for x-ray tomography using synchrotron radiation for biomedical uses and fluid flow modeling, and outlines advantages for using monoenergetic x-rays. Contrast mechanisms are briefly described and several graphs of absorbed doses and scattering of x-rays are included. Also presented are schematic diagrams of computerized tomographic instrumentation with camera head. A brief description of goals for a real time tomographic system and expected improvements to the system are described. Color photomicrographs of the Berea Sandstone and human bone are provided, as well as a 3-D microtomographic reconstruction of a human vertebra sample.

  8. Which test for CAD should be used in patients with left bundle branch block?

    PubMed

    Xu, Bo; Cremer, Paul; Jaber, Wael; Moir, Stuart; Harb, Serge C; Rodriguez, L Leonardo

    2018-03-01

    Exercise stress electrocardiography is unreliable as a test for obstructive coronary artery disease (CAD) if the patient has left bundle branch block. The authors provide an algorithm for using alternative tests: exercise stress echocardiography, dobutamine echocardiography, computed tomographic (CT) angiography, and nuclear myocardial perfusion imaging. Copyright © 2018 Cleveland Clinic.

  9. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    PubMed

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  10. The economic potential of CT scanners for hardwood sawmills

    Treesearch

    Donald G. Hodges; Walter C. Anderson; Charles W. McMillin

    1990-01-01

    Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...

  11. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    PubMed

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Mapping the vascular anatomy of free transplanted soft tissue flaps with computed tomographic angiography.

    PubMed

    Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R

    2012-05-01

    The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011

  13. Roles of Transesophageal Echocardiography and Cardiac Computed Tomography for Evaluation of Left Atrial Thrombus and Associated Pathology: A Review and Critical Analysis.

    PubMed

    Pathan, Faraz; Hecht, Harvey; Narula, Jagat; Marwick, Thomas H

    2018-04-01

    Evaluation of the left atrium and left atrial appendage for the presence of thrombus prior to cardioversion and pulmonary vein isolation, and of the entire heart for embolic sources in the setting of cryptogenic stroke, has long been standard medical care. Guidelines have uniformly recommended transesophageal echocardiography (TEE) to accomplish these goals. In recent years, computed tomographic angiography has demonstrated diagnostic accuracy similar to that of TEE for the detection of thrombus. Analysis of the pertinent data and relative merits of the 2 technologies leads to the conclusions that: 1) both modalities have some unique, nonoverlapping capabilities that may dictate their use in specific situations; 2) computed tomographic angiography is a reasonable alternative to TEE when the primary aim is to exclude left atrial and left atrial appendage thrombus and in patients in whom the risks associated with TEE outweigh the benefits; and 3) both options should be discussed with the patient in the setting of shared decision making. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. [Evaluation of the risk of mediastinal or retroperitoneal injuries caused by dorso-lumbar pedicle screws].

    PubMed

    Hernigou, P; Germany, W

    1998-09-01

    Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of metallic markers and the respect of a safe vertebral zone on X Rays could guide the choice of the appropriate screw length.

  15. Association of Inter-arm Blood Pressure Difference with Asymptomatic Intracranial and Extracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-07-14

    Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24-3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309-3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study.

  16. Successful Resection of a Large Carotid Body Tumor Masquerading Complete Encasement of the Internal Carotid Artery on Preoperative Imaging.

    PubMed

    Kakkos, Stavros K; Zampakis, Peter; Lampropoulos, George C; Paridis, Leonidas; Kaplanis, Charalampos; Bantouna, Dimitra; Nikolakopoulos, Konstantinos M; Papageorgopoulou, Chrysanthi P; Kalogeropoulou, Christina; Tsolakis, Ioannis A

    2018-05-01

    A 41-year-old woman presented with a large painful and tender mass of the left side of her neck located just below the angle of the mandible. She was also complaining of frequent attacks of symptoms ranging from dizziness upon resuming the erect position to frank syncope. Color-coded duplex showed a large well-vascularized vascular mass at the level of the carotid bifurcation, suggesting the diagnosis of a carotid body tumor (CBT). A computerized tomographic angiography confirmed the diagnosis of a CBT, which measured 5.7 cm in its craniocaudal axis. The tumor appeared to encase the internal carotid artery (ICA) at the level of its origin, indicating the presence of a Shamblin group 3 tumor. During surgery, the CBT seemingly encased the ICA; however, it was successfully taken off the ICA, by establishing an adventitial dissection place, obviating the need for arterial resection and replacement. A brief intraoperative episode of cardiac arrest was successfully managed. Postoperative course was uneventful, and all symptoms were cured. Pathology confirmed the clinical diagnosis and did not show malignancy. In conclusion, meticulous surgical techniques can spare the ICA from removal or inadvertent injury during CBT surgery and reduce the morbidity often associated with the resection of large or advanced tumors but also cure atypical patient symptoms.

  17. Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke.

    PubMed

    d'Esterre, Christopher D; Boesen, Mari E; Ahn, Seong Hwan; Pordeli, Pooneh; Najm, Mohamed; Minhas, Priyanka; Davari, Paniz; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V; Zini, Andrea; Frayne, Richard; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Forkert, Nils D; Goyal, Mayank; Lee, Ting Y; Menon, Bijoy K

    2015-12-01

    Among patients with acute ischemic stroke, we determine computed tomographic perfusion (CTP) thresholds associated with follow-up infarction at different stroke onset-to-CTP and CTP-to-reperfusion times. Acute ischemic stroke patients with occlusion on computed tomographic angiography were acutely imaged with CTP. Noncontrast computed tomography and magnectic resonance diffusion-weighted imaging between 24 and 48 hours were used to delineate follow-up infarction. Reperfusion was assessed on conventional angiogram or 4-hour repeat computed tomographic angiography. Tmax, cerebral blood flow, and cerebral blood volume derived from delay-insensitive CTP postprocessing were analyzed using receiver-operator characteristic curves to derive optimal thresholds for combined patient data (pooled analysis) and individual patients (patient-level analysis) based on time from stroke onset-to-CTP and CTP-to-reperfusion. One-way ANOVA and locally weighted scatterplot smoothing regression was used to test whether the derived optimal CTP thresholds were different by time. One hundred and thirty-two patients were included. Tmax thresholds of >16.2 and >15.8 s and absolute cerebral blood flow thresholds of <8.9 and <7.4 mL·min(-1)·100 g(-1) were associated with infarct if reperfused <90 min from CTP with onset <180 min. The discriminative ability of cerebral blood volume was modest. No statistically significant relationship was noted between stroke onset-to-CTP time and the optimal CTP thresholds for all parameters based on discrete or continuous time analysis (P>0.05). A statistically significant relationship existed between CTP-to-reperfusion time and the optimal thresholds for cerebral blood flow (P<0.001; r=0.59 and 0.77 for gray and white matter, respectively) and Tmax (P<0.001; r=-0.68 and -0.60 for gray and white matter, respectively) parameters. Optimal CTP thresholds associated with follow-up infarction depend on time from imaging to reperfusion. © 2015 American Heart Association, Inc.

  18. Indocyanine green laser angiography improves deep inferior epigastric perforator flap outcomes following abdominal suction lipectomy.

    PubMed

    Casey, William J; Connolly, Katharine A; Nanda, Alisha; Rebecca, Alanna M; Perdikis, Galen; Smith, Anthony A

    2015-03-01

    The reliability of deep inferior epigastric artery perforator (DIEP) flap reconstruction following abdominal liposuction is controversial. The authors' early cases were technically successful; however, they experienced high partial flap loss and fat necrosis rates. The authors sought to compare DIEP flap outcomes in the setting of prior liposuction after the use of intraoperative indocyanine green angiography compared to when flaps were assessed on clinical grounds alone. A retrospective review of a consecutive series of DIEP flaps following liposuction at a single institution was performed, comparing those evaluated on clinical grounds alone and those in which indocyanine green angiography was used intraoperatively. Outcomes measured included anastomotic complications, total flap loss, partial flap loss, fat necrosis, and postoperative abdominal wounds. Thirteen DIEP flaps following prior liposuction were performed on 11 patients from July of 2003 through January of 2014. All patients had preoperative imaging with duplex ultrasound or computed tomographic angiography to analyze perforator suitability before surgical exploration. Seven flaps were evaluated intraoperatively on clinical grounds alone. Six flaps were assessed and modified based on indocyanine green angiography. All flaps were successful; however, partial flap loss and fat necrosis rates dropped from 71.4 percent to 0 percent when indocyanine green angiography was used intraoperatively (p = 0.02). Indocyanine green angiography is an excellent vascular imaging modality for intraoperative use to assess flap perfusion, and improves outcomes in DIEP flaps when harvested after prior abdominal suction lipectomy.

  19. Combining Spot Sign and Intracerebral Hemorrhage Score to Estimate Functional Outcome: Analysis From the PREDICT Cohort.

    PubMed

    Schneider, Hauke; Huynh, Thien J; Demchuk, Andrew M; Dowlatshahi, Dar; Rodriguez-Luna, David; Silva, Yolanda; Aviv, Richard; Dzialowski, Imanuel

    2018-06-01

    The intracerebral hemorrhage (ICH) score is the most commonly used grading scale for stratifying functional outcome in patients with acute ICH. We sought to determine whether a combination of the ICH score and the computed tomographic angiography spot sign may improve outcome prediction in the cohort of a prospective multicenter hemorrhage trial. Prospectively collected data from 241 patients from the observational PREDICT study (Prediction of Hematoma Growth and Outcome in Patients With Intracerebral Hemorrhage Using the CT-Angiography Spot Sign) were analyzed. Functional outcome at 3 months was dichotomized using the modified Rankin Scale (0-3 versus 4-6). Performance of (1) the ICH score and (2) the spot sign ICH score-a scoring scale combining ICH score and spot sign number-was tested. Multivariable analysis demonstrated that ICH score (odds ratio, 3.2; 95% confidence interval, 2.2-4.8) and spot sign number (n=1: odds ratio, 2.7; 95% confidence interval, 1.1-7.4; n>1: odds ratio, 3.8; 95% confidence interval, 1.2-17.1) were independently predictive of functional outcome at 3 months with similar odds ratios. Prediction of functional outcome was not significantly different using the spot sign ICH score compared with the ICH score alone (spot sign ICH score area under curve versus ICH score area under curve: P =0.14). In the PREDICT cohort, a prognostic score adding the computed tomographic angiography-based spot sign to the established ICH score did not improve functional outcome prediction compared with the ICH score. © 2018 American Heart Association, Inc.

  20. Comprehensive Digital Imaging Network Project At Georgetown University Hospital

    NASA Astrophysics Data System (ADS)

    Mun, Seong K.; Stauffer, Douglas; Zeman, Robert; Benson, Harold; Wang, Paul; Allman, Robert

    1987-10-01

    The radiology practice is going through rapid changes due to the introduction of state-of-the-art computed based technologies. For the last twenty years we have witnessed the introduction of many new medical diagnostic imaging systems such as x-ray computed tomo-graphy, digital subtraction angiography (DSA), computerized nuclear medicine, single pho-ton emission computed tomography (SPECT), positron emission tomography (PET) and more re-cently, computerized digital radiography and nuclear magnetic resonance imaging (MRI). Other than the imaging systems, there has been a steady introduction of computed based information systems for radiology departments and hospitals.

  1. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  2. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  3. The Basilar Artery on Computed Tomography Angiography Prognostic Score for Basilar Artery Occlusion.

    PubMed

    Alemseged, Fana; Shah, Darshan G; Diomedi, Marina; Sallustio, Fabrizio; Bivard, Andrew; Sharma, Gagan; Mitchell, Peter J; Dowling, Richard J; Bush, Steven; Yan, Bernard; Caltagirone, Carlo; Floris, Roberto; Parsons, Mark W; Levi, Christopher R; Davis, Stephen M; Campbell, Bruce C V

    2017-03-01

    Basilar artery occlusion is associated with high risk of disability and mortality. This study aimed to assess the prognostic value of a new radiological score: the Basilar Artery on Computed Tomography Angiography (BATMAN) score. A retrospective analysis of consecutive stroke patients with basilar artery occlusion diagnosed on computed tomographic angiography was performed. BATMAN score is a 10-point computed tomographic angiography-based grading system which incorporates thrombus burden and the presence of collaterals. Reliability was assessed with intraclass coefficient correlation. Good outcome was defined as modified Rankin Scale score of ≤3 at 3 months and successful reperfusion as thrombolysis in cerebral infarction 2b-3. BATMAN score was externally validated and compared with the Posterior Circulation Collateral score. The derivation cohort included 83 patients with 41 in the validation cohort. In receiver operating characteristic (ROC) analysis, BATMAN score had an area under receiver operating characteristic curve of 0.81 (95% confidence interval [CI], 0.7-0.9) in derivation cohort and an area under receiver operating characteristic curve of 0.74 (95% CI, 0.6-0.9) in validation cohort. In logistic regression adjusted for age and clinical severity, BATMAN score of <7 was associated with poor outcome in derivation cohort (odds ratio, 5.5; 95% CI, 1.4-21; P =0.01), in validation cohort (odds ratio, 6.9; 95% CI, 1.4-33; P =0.01), and in endovascular patients, after adjustment for recanalization and time to treatment (odds ratio, 4.8; 95% CI, 1.2-18; P =0.01). BATMAN score of <7 was not associated with recanalization. Interrater agreement was substantial (intraclass coefficient correlation, 0.85; 95% CI, 0.8-0.9). BATMAN score had greater accuracy compared with Posterior Circulation Collateral score ( P =0.04). The addition of collateral quality to clot burden in BATMAN score seems to improve prognostic accuracy in basilar artery occlusion patients. © 2017 American Heart Association, Inc.

  4. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, J.H.; Bonse, U.K.; Johnson, Q.C.; Nichols, M.C.; Saroyan, R.A.; Massey, W.N.; Nusshardt, R.

    1993-09-14

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: (a) source means for providing a source of parallel x-ray beams, (b) staging means for staging and sequentially rotating a sample to be positioned in the path of the (c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, (d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and (e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor. 25 figures.

  5. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, John H.; Bonse, Ulrich K.; Johnson, Quintin C.; Nichols, Monte C.; Saroyan, Ralph A.; Massey, Warren N.; Nusshardt, Rudolph

    1993-01-01

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: a) source means for providing a source of parallel x-ray beams, b) staging means for staging and sequentially rotating a sample to be positioned in the path of the c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor.

  6. Gadopentetate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning.

    PubMed

    Gupta, Atul K; Alberico, Ronald A; Litwin, Alan; Kanter, Peter; Grossman, Zachary D

    2002-01-01

    To demonstrate that gadopentetate dimeglumine is potentially an alternative contrast medium for computed tomographic angiography (CTA). One 12.2-kg Beagle dog was studied as proof of principle; the cervical vessels of three adult human patients were imaged for presurgical planning of the neck. Gadopentetate dimeglumine, 0.5 mol/l (Berlex Laboratories, Wayne, NJ, U.S.A.), a LightSpeed QX/i CT (General Electric Medical Systems, Milwaukee, WI, U.S.A.), and an Ultra Sparc II (SUN Microsystems, Santa Clara, CA, U.S.A.) running Advantage Windows 3.1 (General Electric Medical Systems) were used. Sufficient enhancement for CTA of the thoracic aorta, cervical vessels, and abdominal vessels was produced in the experimental dog, and the cervical vessels were clearly defined in all three patients. In that subset of patients with contraindications to iodinated contrast medium and for whom magnetic resonance angiography is inappropriate, gadopentetate dimeglumine may be an alternative contrast medium for CTA.

  7. Anthropometric and computerized tomographic measurements of lower extremity lean body mass.

    PubMed

    Buckley, D C; Kudsk, K A; Rose, B S; Fatzinger, P; Koetting, C A; Schlatter, M

    1987-02-01

    The loss of lean muscle mass is one of the hallmarks of protein-calorie malnutrition. Anthropometry is a standardized technique used to assess the response of muscle mass to nutrition therapy by quantifying the muscle and fat compartments. That technique does not accurately reflect actual limb composition, whereas computerized tomography does. Twenty lower extremities on randomly chosen men and women patients were evaluated by anthropometry and computerized tomography. Total area, muscle plus bone area, total volume, and muscle plus bone volume were correlated, using Heymsfield's equation and computerized tomography-generated areas. Anthropometrics overestimated total and muscle plus bone cross-sectional areas at almost every level. Anthropometry overestimated total area and total volume by 5% to 10% but overestimated muscle plus bone area and muscle plus bone volume by as much as 40%. Anthropometry, while easily performed and useful in large population groups for epidemiological studies, offers a poor assessment of lower extremity composition. On the other hand, computerized tomography is also easily performed and, while impractical for large population groups, does offer an accurate assessment of the lower extremity tissue compartments and is an instrument that might be used in research on lean muscle mass.

  8. Computerized tomography with 3-dimensional reconstruction for the evaluation of renal size and arterial anatomy in the living kidney donor.

    PubMed

    Janoff, Daniel M; Davol, Patrick; Hazzard, James; Lemmers, Michael J; Paduch, Darius A; Barry, John M

    2004-01-01

    Computerized tomography (CT) with 3-dimensional (3-D) reconstruction has gained acceptance as an imaging study to evaluate living renal donors. We report our experience with this technique in 199 consecutive patients to validate its predictions of arterial anatomy and kidney volumes. Between January 1997 and March 2002, 199 living donor nephrectomies were performed at our institution using an open technique. During the operation arterial anatomy was recorded as well as kidney weight in 98 patients and displacement volume in 27. Each donor had been evaluated preoperatively by CT angiography with 3-D reconstruction. Arterial anatomy described by a staff radiologist was compared with intraoperative findings. CT estimated volumes were reported. Linear correlation graphs were generated to assess the reliability of CT volume predictions. The accuracy of CT angiography for predicting arterial anatomy was 90.5%. However, as the number of renal arteries increased, predictive accuracy decreased. The ability of CT to predict multiple arteries remained high with a positive predictive value of 95.2%. Calculated CT volume and kidney weight significantly correlated (0.654). However, the coefficient of variation index (how much average CT volume differed from measured intraoperative volume) was 17.8%. CT angiography with 3-D reconstruction accurately predicts arterial vasculature in more than 90% of patients and it can be used to compare renal volumes. However, accuracy decreases with multiple renal arteries and volume comparisons may be inaccurate when the difference in kidney volumes is within 17.8%.

  9. Dyspnea predicts mortality among patients undergoing coronary computed tomographic angiography.

    PubMed

    Nakanishi, Rine; Gransar, Heidi; Rozanski, Alan; Rana, Jamal S; Cheng, Victor Y; Thomson, Louise E J; Miranda-Peats, Romalisa; Dey, Damini; Hayes, Sean W; Friedman, John D; Min, James K; Berman, Daniel S

    2016-02-01

    The prognostic implications of dyspnea and typical angina in patients referred for coronary CT angiography have not been examined. We examined features associated with incident mortality risk among individuals undergoing coronary computed tomographic angiography (CCTA) presenting with dyspnea, typical angina, and neither of these symptoms. 1147 consecutive individuals without known CAD (mean 61 years, 61.6 %men) undergoing CCTA comprised the study population 132 with dyspnea, 218 with typical angina, and 797 without dyspnea or typical angina (reference group). Mortality risk in relation to dyspnea or typical angina was evaluated with multivariable Cox proportional hazards models compared to reference. In addition, the prognosis associated with dyspnea or typical angina was assessed among age matched subgroups. Patients with dyspnea had a greater prevalence of C70 % stenosis (p\\0.001) and coronary segments with plaque (p = 0.02) compared to the other two groups. During a follow-up of 3.1 years, 52 individuals died. By multivariable Cox models, compared to patients in reference group, dyspnea patients experienced higher mortality (HR 2.0, 95 % CI 1.0–4.0, p = 0.049) while typical angina patients did not (HR 1.1, 95 % CI 0.6–2.3, p = 0.76). In the matched group, the patients with dyspnea (HR 2.2, 95 % CI 1.1–4.3, p = 0.03) still had significantly reduced survival compared to the other two groups, while those with typical angina did not (HR 1.2, 95 % CI 0.6–2.6,p = 0.62). Dyspnea is associated with increased mortality ate compared to patients with typical angina and those with neither of these symptoms among patients undergoing CCTA.

  10. Comparison of frequency of calcified versus non-calcified coronary lesions by computed tomographic angiography in patients with stable versus unstable angina pectoris.

    PubMed

    Meijs, Matthijs F L; Meijboom, W Bob; Bots, Michiel L; Kyrzopoulos, Stamatis; Eu, Rick Neoh; Prokop, Mathias; Doevendans, Pieter A; de Feyter, Pim J; Cramer, Maarten J

    2009-08-01

    Computed tomographic coronary angiography (CTCA) can noninvasively identify calcified and noncalcified coronary plaques. The aim of this study was to compare the phenotypes of all plaques and of culprit plaques between patients with unstable angina pectoris (UAP) and those with stable angina pectoris (SAP), because plaque characteristics may differ between these patients. In 110 patients with UAP and 189 with SAP from a multicenter study comparing 64-slice CTCA with conventional coronary angiography, the number and phenotypes (noncalcified, mixed, and calcified) of coronary plaques were compared. In a subanalysis in 50 patients with UAP and 64 with SAP, culprit plaque characteristics, including culprit plaque cross-sectional area relative to total vessel cross-sectional area, culprit plaque length, remodeling index, and spotty calcification, were determined. Odds ratios for the presence of UAP, adjusted for clinical variables and the total number of plaques, were calculated for plaque characteristics on CTCA. Although the number of plaques was similar for patients with UAP and those with SAP, plaques in patients with UAP were more frequently noncalcified than in patients with SAP. The odds ratio for UAP was 1.3 (95% confidence interval [CI] 1.1 to 1.5) per noncalcified plaque. In the culprit plaque subanalysis, odds ratios for UAP were 0.99 (95% CI 0.96 to 1.01) per millimeter culprit plaque length, 2.7 (95% CI 1.2 to 6.4) for noncalcified culprit plaque, and 1.06 (95% CI 0.99 to 1.13) per percentage relative culprit plaque cross-sectional area. No significant relation was found between remodeling index or spotty calcification and UAP. In conclusion, noncalcified plaques and large noncalcified culprit plaques are more frequently found in patients with UAP than in those with SAP.

  11. Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses.

    PubMed

    Rubin, G D; Armerding, M D; Dake, M D; Napel, S

    2000-04-01

    To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.

  12. PubMed Central

    Laplante, L; Everett, J

    1992-01-01

    Many attempts to isolate a dysfunctional site in the brain of schizophrenic patients have converged in a neuropathological conception of the disease based on frontal lobe hypoactivity. Recent data from studies using cytoarchitectony, computerized tomographic scans, cerebral regional blood flow, smooth pursuit eye movements and neuropsychological assessments are discussed. Current data on the hypofrontality hypothesis in schizophrenia seem to suggest an associationist rather than a localisationist perspective of the disorder. PMID:1489762

  13. Computed Tomography Status

    DOE R&D Accomplishments Database

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  14. Ultrafast CT scanning of an oak log for internal defects

    Treesearch

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  15. Morphological Analysis of Bronchial Arteries and Variants with Computed Tomography Angiography.

    PubMed

    Esparza-Hernández, Claudia Nallely; Ramírez-González, Juan Manuel; Cuéllar-Lozano, Rolando Alberto; Morales-Avalos, Rodolfo; González-Arocha, Carla Sofía; Martínez-González, Brenda; Quiroga-Garza, Alejandro; Pinales-Razo, Ricardo; Elizondo-Riojas, Guillermo; Elizondo-Omaña, Rodrigo Enrique; Guzmán-López, Santos

    2017-01-01

    The aim of our study was to determine the prevalence of anatomical variants of bronchial arteries using computed tomographic angiography in a population of northeastern Mexico. An observational, transversal, descriptive, comparative, retrospective study was performed using 139 imaging studies of Mexican patients in which we evaluated the following parameters from the left and right bronchial arteries: artery origin, branching pattern, arterial ostium, vertebral level of origin, diameter, and mediastinal trajectory. The anatomies of the bronchial arteries were similar in both genders, except distribution for vertebral origin level ( p   0.006) and the diameter ( p   0.013). Left and right arteries were similar, except for the mediastinal trajectory in reference to the esophagus ( p < 0.001) as well as the arterial diameter ( p < 0.001) and lumen diameter.

  16. [Spiral CT angiography in practice].

    PubMed

    Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko

    2005-01-01

    Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.

  17. Association of Inter-arm Blood Pressure Difference with Asymptomatic Intracranial and Extracranial Arterial Stenosis in Hypertension Patients

    PubMed Central

    Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-01-01

    Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24–3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309–3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study. PMID:27412818

  18. Laser-assisted indocyanine green angiography: a critical appraisal.

    PubMed

    Wu, Cindy; Kim, Sendia; Halvorson, Eric G

    2013-05-01

    Laser-assisted indocyanine green angiography (ICG-A) has been promoted to assess perfusion of random skin, pedicled, and free flaps. Few studies address its potential limitations. Thirty-seven patients who underwent reconstructive procedures with ICG-A were studied retrospectively to determine the correlation between clinical findings and ICG-A. Indocyanine green angiography underestimated perfusion when areas of less than or equal to 25% uptake were not debrided and remained perfused. Indocyanine green angiography overestimated perfusion when areas with greater than 25% uptake developed necrosis. Of 14 random skin flaps, ICG-A underestimated perfusion in 14% and overestimated in 14%. In 16 patients undergoing perforator flap breast reconstruction, ICG-A correlated with computed tomographic angiogram (CTA) in 85%. Indocyanine green angiography underestimated perfusion in 7% and overestimated in 7%. In 8/11 patients undergoing fasciocutaneous flaps, ICG-A aided in donor site selection. In 3/6 ALT flaps, a better unilateral blush was found that correlated with Doppler. In all 3, a dominant perforator was found. In 11 patients, there was a 9% underestimation of flap perfusion. In 3 pedicled flaps, there was a 66% underestimation and 33% overestimation of perfusion. Indocyanine green angiography often confirmed our clinical/radiologic findings in abdominal perforator and fasciocutaneous flaps. It tended to underestimate perfusion in pedicle and skin flaps. When clinical examination was obvious, ICG-A rendered clear-cut findings. When clinical examination was equivocal, ICG-A tended to provide ambiguous findings, demonstrating that a distinct cutoff point does not exists for every patient or flap. Indocyanine green angiography is a promising but expensive technology that would benefit from standardization. Further research is needed before ICG-A can become a reliable tool for surgeons.

  19. Prognostic and therapeutic implications of statin and aspirin therapy in individuals with nonobstructive coronary artery disease: results from the CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter registry) registry.

    PubMed

    Chow, Benjamin J W; Small, Gary; Yam, Yeung; Chen, Li; McPherson, Ruth; Achenbach, Stephan; Al-Mallah, Mouaz; Berman, Daniel S; Budoff, Matthew J; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Cheng, Victor Y; Chinnaiyan, Kavitha; Cury, Ricardo; Delago, Augustin; Dunning, Allison; Feuchtner, Gundrun; Hadamitzky, Martin; Hausleiter, Jörg; Karlsberg, Ronald P; Kaufmann, Philipp A; Kim, Yong-Jin; Leipsic, Jonathon; LaBounty, Troy; Lin, Fay; Maffei, Erica; Raff, Gilbert L; Shaw, Leslee J; Villines, Todd C; Min, James K

    2015-04-01

    We sought to examine the risk of mortality associated with nonobstructive coronary artery disease (CAD) and to determine the impact of baseline statin and aspirin use on mortality. Coronary computed tomographic angiography permits direct visualization of nonobstructive CAD. To date, the prognostic implications of nonobstructive CAD and the potential benefit of directing therapy based on nonobstructive CAD have not been carefully examined. A total of 27 125 consecutive patients who underwent computed tomographic angiography (12 enrolling centers and 6 countries) were prospectively entered into the COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter (CONFIRM) registry. Patients, without history of previous CAD or obstructive CAD, for whom baseline statin and aspirin use was available were analyzed. Each coronary segment was classified as normal or nonobstructive CAD (1%-49% stenosis). Patients were followed up for a median of 27.2 months for all-cause mortality. The study comprised 10 418 patients (5712 normal and 4706 with nonobstructive CAD). In multivariable analyses, patients with nonobstructive CAD had a 6% (95% confidence interval, 1%-12%) higher risk of mortality for each additional segment with nonobstructive plaque (P=0.021). Baseline statin use was associated with a reduced risk of mortality (hazard ratio, 0.44; 95% confidence interval, 0.28-0.68; P=0.0003), a benefit that was present for individuals with nonobstructive CAD (hazard ratio, 0.32; 95% confidence interval, 0.19-0.55; P<0.001) but not for those without plaque (hazard ratio, 0.66; 95% confidence interval, 0.30-1.43; P=0.287). When stratified by National Cholesterol Education Program/Adult Treatment Program III, no mortality benefit was observed in individuals without plaque. Aspirin use was not associated with mortality benefit, irrespective of the status of plaque. The presence and extent of nonobstructive CAD predicted mortality. Baseline statin therapy was associated with a significant reduction in mortality for individuals with nonobstructive CAD but not for individuals without CAD. URL: http://clinicaltrials.gov/. Unique identifier NCT01443637. © 2015 American Heart Association, Inc.

  20. Is There a Role for Empiric Gastroduodenal Artery Embolization in the Management of Patients with Active Upper GI Hemorrhage?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com; Chan, Victoria, E-mail: dr.victoriac@gmail.com; Shrivastava, Vivek, E-mail: vivshriv@yahoo.com

    2013-08-01

    PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patientsmore » who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.« less

  1. Computerized tomographic determination of spinal bone mineral content

    NASA Technical Reports Server (NTRS)

    Cann, C. E.; Genant, H. K.

    1980-01-01

    The aims of the study were three-fold: to determine the magnitude of vertebral cancellous mineral loss in normal subjects during bedrest, to compare this loss with calcium balance and mineral loss in peripheral bones, and to use the vertebral measurements as an evaluative criterion for the C12MDP treatment and compare it with other methods. The methods used are described and the results from 14 subjects are presented.

  2. A Novel Augmented Reality-Based Navigation System in Perforator Flap Transplantation - A Feasibility Study.

    PubMed

    Jiang, Taoran; Zhu, Ming; Zan, Tao; Gu, Bin; Li, Qingfeng

    2017-08-01

    In perforator flap transplantation, dissection of the perforator is an important but difficult procedure because of the high variability in vascular anatomy. Preoperative imaging techniques could provide substantial information about vascular anatomy; however, it cannot provide direct guidance for surgeons during the operation. In this study, a navigation system (NS) was established to overlie a vascular map on surgical sites to further provide a direct guide for perforator flap transplantation. The NS was established based on computed tomographic angiography and augmented reality techniques. A virtual vascular map was reconstructed according to computed tomographic angiography data and projected onto real patient images using ARToolKit software. Additionally, a screw-fixation marker holder was created to facilitate registration. With the use of a tracking and display system, we conducted the NS on an animal model and measured the system error on a rapid prototyping model. The NS assistance allowed for correct identification, as well as a safe and precise dissection of the perforator. The mean value of the system error was determined to be 3.474 ± 1.546 mm. Augmented reality-based NS can provide precise navigation information by directly displaying a 3-dimensional individual anatomical virtual model onto the operative field in real time. It will allow rapid identification and safe dissection of a perforator in free flap transplantation surgery.

  3. The use of intraosseous needles for injection of contrast media for computed tomographic angiography of the thoracic aorta.

    PubMed

    Winkler, Michael; Talley, Cynthia; Woodward, Connor; Kingsbury, Alexander; Appiah, Frank; Elbelasi, Hossam; Landwher, Kevin; Li, Xingzhe; Fleischmann, Dominik

    The objective of this study is to evaluate the safety and quality of computed tomographic angiography of the thoracic aorta (CTA-TA) exams performed using intraosseous needle intravenous access (ION-IVA) for contrast media injection (CMI). All CTA-TA exams at the study institution performed between 1/1/2013 and 8/14/2015 were reviewed retrospectively to identify those exams which had been performed using ION-IVA (ION-exams). ION-exams were then analyzed to determine aortic attenuation and contrast-to-noise ratio (CNR). Linear regression was used to determine how injection rate and other variables affected image quality for ION-exams. Patient electronic medical records were reviewed to identify any adverse events related to CTA-TA or ION-IVA. 17 (∼0.2%) of 7401 exams were ION-exams. ION-exam CMI rates varied between 2.5 and 4 ml/s. Mean attenuation was 312 HU (SD 88 HU) and mean CNR was 25 (SD 9.9). A strong positive linear association between attenuation and injection rate was found. No immediate or delayed complications related to the ION-exams, or intraosseous needle use in general, occurred. For CTA-TA, ION-IVA appears to be a safe and effective route for CMI at rates up to 4 ml/s. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. False positive computed tomographic angiography for Stanford type A aortic dissection.

    PubMed

    Bandali, Murad F; Hatem, Muhammed A; Appoo, Jehangir J; Hutchison, Stuart J; Wong, Jason K

    2015-12-01

    Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Department bedside ultrasound suggesting an intimal flap in the aorta, CTA was requested to better assess the ascending aorta and was interpreted as consistent with Stanford Type A aortic dissection with thrombosis of the false lumen in the ascending aorta. However, intra-operative imaging (TEE and epi-aortic scanning) did not identify an intimal flap or dissection, and neither did definitive surgical inspection of the aorta. The suspected aortic dissection and thrombosed false lumen were not visualized on repeat CTA two days later. False positive diagnosis of Stanford Type A aortic dissection on CTA can be the result of technical factors, streak artifacts, motion artifacts, and periaortic structures. In this case, non-uniform arterial contrast enhancement secondary to unrecognized biventricular dysfunction resulted in the false positive CTA appearance of an intimal flap and mural thrombus. Intra-operative TEE and epi-aortic scanning were proven correct in excluding aortic dissection by the standard of definitive surgical inspection of the aorta.

  5. Presence and severity of noncalcified coronary plaque on 64-slice computed tomographic coronary angiography in patients with zero and low coronary artery calcium.

    PubMed

    Cheng, Victor Y; Lepor, Norman E; Madyoon, Hooman; Eshaghian, Shervin; Naraghi, Ashkan L; Shah, Prediman K

    2007-05-01

    How well absence of coronary artery calcium (CAC) predicts the absence of noncalcified coronary artery plaque (NCAP) has not been elucidated. We conducted a cross-sectional study of 554 outpatients to quantify NCAP prevalence as a function of CAC score. All patients underwent CAC scoring followed by 64-slice computed tomographic coronary angiography. Patients were categorized as having 0 CAC (416 patients) or low CAC (138 patients; men with CAC scores from 1 to 50 and women with scores from 1 to 10). Prevalence of detectable NCAP was 6.5% in patients with 0 CAC and 65.2% in those with low CAC. Compared with patients with 0 CAC, those with low CAC had markedly increased rates of NCAP occluding <50% of the arterial lumen (56.5% vs 6.0%, p <0.001) and > or =50% of the arterial lumen (8.7% vs 0.5%, p <0.001). In conclusion, in outpatients with a low to intermediate risk presentation and no known coronary artery disease, absence of CAC predicts low prevalence of any NCAP and very low prevalence of significantly occlusive NCAP. Low but detectable CAC scores are significantly less reliable in predicting plaque burden due to their association with high overall NCAP prevalence and nearly a 10% rate of significantly occlusive NCAP.

  6. Survival of a pedicled latissimus dorsi flap in breast reconstruction without a thoracodorsal pedicle.

    PubMed

    Hartmann, C E A; Branford, O A; Malhotra, A; Chana, J S

    2013-07-01

    The latissimus dorsi flap, first performed by Tansini in 1892, was popularised for use by Olivari in 1976. The successful transfer of a latissimus dorsi flap during breast reconstruction has previously been thought to be dependent on having an intact thoracodorsal pedicle to ensure flap survival. It is well documented that the flap may also survive on the serratus branch in thoracodorsal pedicle division. We report a case of a 52-year-old female patient who underwent successful delayed breast reconstruction with a latissimus dorsi flap following previous mastectomy and axillary node clearance. Intraoperatively, the thoracodorsal pedicle and serratus branch were found to have been previously divided. On postoperative computer tomographic angiography the thoracodorsal pedicle was shown to be divided together with the serratus branch. The flap was seen to be supplied by the lateral thoracic artery. To our knowledge survival of a pedicled latissimus dorsi flap in breast reconstruction with a vascular supply from this vessel following thoracodorsal pedicle division has not previously been described. Previous thoracodorsal pedicle and serratus branch division may not be an absolute contraindication for the use of the latissimus dorsi flap in breast reconstruction, depending on the results of preoperative Doppler or computer tomographic angiography studies. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Forest representation of vessels in cone-beam computed tomographic angiography.

    PubMed

    Chen, Zikuan; Ning, Ruola

    2005-01-01

    Cone-beam computed tomographic angiography (CBCTA) provides a fast three-dimensional (3D) vascular imaging modality, aiming at digitally representing the spatial vascular structure in an angiographic volume. Due to the finite coverage of cone-beam scan, as well as the volume cropping in volumetric image processing, an angiographic volume may fail to contain a whole vascular tree, but rather consist of a multitude of vessel segments or subtrees. As such, it is convenient to represent multitudinal components by a forest. The vessel tracking issue then becomes component characterization/identification in the forest. The forest representation brings several conveniences for vessel tracking: (1) to sort and count the vessels in an angiographic volume, for example, according to spatial occupancy and skeleton pathlength; (2) to single out a vessel and perform in situ 3D measurement and 3D visualization in the support space; (3) to delineate individual vessels from the original angiographic volume; and (4) to cull the forest by getting rid of non-vessels and small vessels. A 3D skeletonization is used to generate component skeletons. For tree construction from skeletons, we suggest a pathlength-based procedure, which lifts the restrictions of unit-width skeleton and root determination. We experimentally demonstrate the forest representation of a dog's carotid arteries in a CBCTA system. In principle, the forest representation is useful for managing vessels in both 2D angiographic images and 3D angiographic volumes.

  8. Superficial Palmar Arch Aneurysm after Carpal Tunnel Decompression, a Rare Complication: A Case Report

    PubMed Central

    Gull, S.; Spence, R. A. J.; Loan, W.

    2011-01-01

    False aneurysms of the palmar arteries are rare. They are usually associated with traumatic injuries to the hand vasculature. We present a case of superficial palmar arch aneurysm (SPAA), complicating carpal tunnel decompression which presented as a pulsatile mass at the site of previous surgery. Initial diagnosis was made on clinical examination and confirmed on doppler ultrasound (US) and computed tomographic angiography (CTA). The feeding vessel of the aneurysm was subsequently occluded using coil embolization. PMID:21547251

  9. Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans

    DTIC Science & Technology

    2003-09-01

    Computerized analysis of three- dimensional reconstructed scans was also performed, based on Hounsfield unit ranges: hyperinflated, 1,000 to 900; normal...the interactive segmentation function of the software. The pulmonary parenchyma was separated into four regions based on the Hounsfield unit (HU...SII) severity. Methods: Twenty anesthetized sheep underwent graded SII: group I, no smoke; group II, 5 smoke units ; group III, 10 units ; and group IV

  10. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    PubMed

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  11. Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oztunc, Funda, E-mail: foztunc@yahoo.com; Baris, Safa, E-mail: safabaris@hotmail.co; Adaletli, Ibrahim, E-mail: iadaletli@yahoo.com

    2009-03-15

    The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carinamore » up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.« less

  12. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.

    PubMed

    Yang, Pengfei; Niu, Kai; Wu, Yijing; Struffert, Tobias; Dorfler, Arnd; Schafer, Sebastian; Royalty, Kevin; Strother, Charles; Chen, Guang-Hong

    2015-12-01

    Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality and diagnostic value of time-resolved C-arm CTA reconstructed using novel image processing algorithms. Studies were done under an Institutional Review Board approved protocol. Postprocessing of data from 21 C-arm CT dynamic perfusion acquisitions from 17 patients with acute ischemic stroke were done to derive time-resolved C-arm CTA images. Two observers independently evaluated image quality and diagnostic content for each case. ICC and receiver-operating characteristic analysis were performed to evaluate interobserver agreement and diagnostic value of this novel imaging modality. Time-resolved C-arm CTA images were successfully generated from 20 data sets (95.2%, 20/21). Two observers agreed well that the image quality for large cerebral arteries was good but was more limited for small cerebral arteries (distal to M1, A1, and P1). receiver-operating characteristic curves demonstrated excellent diagnostic value for detecting large vessel occlusions (area under the curve=0.987-1). Time-resolved CTAs derived from C-arm CT perfusion acquisitions provide high quality images that allowed accurate diagnosis of large vessel occlusions. Although image quality of smaller arteries in this study was not optimal ongoing modifications of the postprocessing algorithm will likely remove this limitation. Adding time-resolved C-arm CTAs to the capabilities of the angiography suite further enhances its suitability as a one-stop shop for care for patients with acute ischemic stroke. © 2015 American Heart Association, Inc.

  13. An anomalous origin of the gastrosplenic trunk and common hepatic artery arising independently from the abdominal aorta: a case report using MDCT angiography.

    PubMed

    Iacob, Nicoleta; Pusztai, Agneta Maria; Miclăuş, Graţian Dragoslav; Pop, Elena; Matusz, Petru

    2018-01-01

    The authors describe a case of a 61-year-old female patient, which presented on multidetector computed tomographic (MDCT) angiography a gastrosplenic trunk (GST) and common hepatic artery (CHA) arose independently from abdominal aorta (AA). The GST arose from the anterior wall of the AA, at the level of upper edge of the L1 vertebral body. The left gastric artery (LGA) arose from the superior wall of the GST. The splenic artery (SA) continuous the path of GST. The CHA arose from the anterior wall of the AA, at the level of upper one third of the L1 vertebral body, at 15.3 mm above the origin of superior mesenteric artery (SMA). The incidence and developmental and clinical significance of this vascular variation is discussed with a detailed review of the literature.

  14. Majewski osteodysplastic primordial dwarfism type II (MOPD II): expanding the vascular phenotype.

    PubMed

    Bober, Michael B; Khan, Nadia; Kaplan, Jennifer; Lewis, Kristi; Feinstein, Jeffrey A; Scott, Charles I; Steinberg, Gary K

    2010-04-01

    Majewski Osteodysplastic Primordial Dwarfism, Type II (MOPD II) is a rare, autosomal recessive disorder. Features include severe intrauterine growth retardation (IUGR), poor postnatal growth (adult stature approximately 100 cm), severe microcephaly, skeletal dysplasia, characteristic facial features, and normal or near normal intelligence. An Institutional Review Board (IRB) approved registry was created and currently follows 25 patients with a diagnosis of MOPD II. Based on previous studies, a neurovascular screening program was implemented and 13 (52%) of these patients have been found to have cerebral neurovascular abnormalities including moyamoya angiopathy and/or intracranial aneurysms. The typical moyamoya pathogenesis begins with vessel narrowing in the supraclinoid internal carotid artery, anterior cerebral (A1) or middle cerebral (M1) artery segments. The narrowing may predominate initially on one side, progresses to bilateral stenosis, with subsequent occlusion of the vessels and collateral formation. We present four patients who, on neurovascular screening, were found to have cerebrovascular changes. Two were asymptomatic, one presented with a severe headache and projectile vomiting related to a ruptured aneurysm, and one presented after an apparent decline in cognitive functioning. Analysis of the registry suggests screening for moyamoya disease be performed at the time of MOPD II diagnosis and at least every 12-18 months using MRA or computerized tomographic angiography (CTA). We believe this is imperative. If diagnosed early enough, re-vascularization and aneurysm treatment in skilled hands can be performed safely and prevent or minimize long-term sequelae in this population. Emergent evaluation is also needed when other neurologic or cardiac symptoms are present. (c) 2010 Wiley-Liss, Inc.

  15. Identification of High-Risk Plaques Destined to Cause Acute Coronary Syndrome Using Coronary Computed Tomographic Angiography and Computational Fluid Dynamics.

    PubMed

    Lee, Joo Myung; Choi, Gilwoo; Koo, Bon-Kwon; Hwang, Doyeon; Park, Jonghanne; Zhang, Jinlong; Kim, Kyung-Jin; Tong, Yaliang; Kim, Hyun Jin; Grady, Leo; Doh, Joon-Hyung; Nam, Chang-Wook; Shin, Eun-Seok; Cho, Young-Seok; Choi, Su-Yeon; Chun, Eun Ju; Choi, Jin-Ho; Nørgaard, Bjarne L; Christiansen, Evald H; Niemen, Koen; Otake, Hiromasa; Penicka, Martin; de Bruyne, Bernard; Kubo, Takashi; Akasaka, Takashi; Narula, Jagat; Douglas, Pamela S; Taylor, Charles A; Kim, Hyo-Soo

    2018-03-14

    We investigated the utility of noninvasive hemodynamic assessment in the identification of high-risk plaques that caused subsequent acute coronary syndrome (ACS). ACS is a critical event that impacts the prognosis of patients with coronary artery disease. However, the role of hemodynamic factors in the development of ACS is not well-known. Seventy-two patients with clearly documented ACS and available coronary computed tomographic angiography (CTA) acquired between 1 month and 2 years before the development of ACS were included. In 66 culprit and 150 nonculprit lesions as a case-control design, the presence of adverse plaque characteristics (APC) was assessed and hemodynamic parameters (fractional flow reserve derived by coronary computed tomographic angiography [FFR CT ], change in FFR CT across the lesion [△FFR CT ], wall shear stress [WSS], and axial plaque stress) were analyzed using computational fluid dynamics. The best cut-off values for FFR CT , △FFR CT , WSS, and axial plaque stress were used to define the presence of adverse hemodynamic characteristics (AHC). The incremental discriminant and reclassification abilities for ACS prediction were compared among 3 models (model 1: percent diameter stenosis [%DS] and lesion length, model 2: model 1 + APC, and model 3: model 2 + AHC). The culprit lesions showed higher %DS (55.5 ± 15.4% vs. 43.1 ± 15.0%; p < 0.001) and higher prevalence of APC (80.3% vs. 42.0%; p < 0.001) than nonculprit lesions. Regarding hemodynamic parameters, culprit lesions showed lower FFR CT and higher △FFR CT , WSS, and axial plaque stress than nonculprit lesions (all p values <0.01). Among the 3 models, model 3, which included hemodynamic parameters, showed the highest c-index, and better discrimination (concordance statistic [c-index] 0.789 vs. 0.747; p = 0.014) and reclassification abilities (category-free net reclassification index 0.287; p = 0.047; relative integrated discrimination improvement 0.368; p < 0.001) than model 2. Lesions with both APC and AHC showed significantly higher risk of the culprit for subsequent ACS than those with no APC/AHC (hazard ratio: 11.75; 95% confidence interval: 2.85 to 48.51; p = 0.001) and with either APC or AHC (hazard ratio: 3.22; 95% confidence interval: 1.86 to 5.55; p < 0.001). Noninvasive hemodynamic assessment enhanced the identification of high-risk plaques that subsequently caused ACS. The integration of noninvasive hemodynamic assessments may improve the identification of culprit lesions for future ACS. (Exploring the Mechanism of Plaque Rupture in Acute Coronary Syndrome Using Coronary CT Angiography and Computational Fluid Dynamic [EMERALD]; NCT02374775). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Intrinsic, Transitional, and Extrinsic Morphological Factors Associated With Rupture of Intracranial Aneurysms.

    PubMed

    Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose

    2015-09-01

    As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.

  17. Association Between Carotid Bulb Diaphragm and Ischemic Stroke in Young Afro-Caribbean Patients: A Population-Based Case-Control Study.

    PubMed

    Joux, Julien; Boulanger, Marion; Jeannin, Severine; Chausson, Nicolas; Hennequin, Jean-Luc; Molinié, Vincent; Smadja, Didier; Touzé, Emmanuel; Olindo, Stephane

    2016-10-01

    Carotid bulb diaphragm (CBD) has been described in young carotid ischemic stroke (CIS) patients, especially in blacks. However, the prevalence of CBD in CIS patients is unknown, and whether CBD is a risk factor for CIS remains unclear. We assessed the association between CBD and incident CIS in a population-based study. We selected all young (<55 years) CIS patients from a 1-year population-based cohort study in the Afro-Caribbean population of Martinique in 2012. All patients had a comprehensive work-up including a computed tomographic angiography. We calculated CIS associated with ipsilateral CBD incidence with 95% confidence intervals using Poisson distribution. We then selected age- and sex-matched controls among young (<55 years) Afro-Caribbean stroke-free patients admitted for a road crash who routinely had computed tomographic angiography. Odds ratio (ORs) were calculated by conditional logistic regression adjusted for hypertension, dyslipidemia, diabetes and smoking. CIS associated with ipsilateral CBD incidence was 3.8 per 100 000 person-years (95% confidence interval, 1.4-6.1). Prevalence of ipsilateral CBD was 23% in all CIS and 37% in undetermined CIS patients. When restricted to undetermined CIS, CBD prevalence was 24 times higher than that in controls (adjusted OR, 24.1; 95% confidence interval, 1.8-325.6). CBD is associated with an increased risk of ipsilateral CIS in young Afro-Caribbean population. © 2016 American Heart Association, Inc.

  18. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    PubMed Central

    Kim, Jong Gyu

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839

  19. Three-dimensional reconstruction of the peripancreatic vascular system based on computed tomographic angiography images and its clinical application in the surgical management of pancreatic tumors.

    PubMed

    Fang, Chi-hua; Kong, Deshuai; Wang, Xiaojun; Wang, Huaizhi; Xiang, Nan; Fan, Yingfang; Yang, Jian; Zhong, Shi Zheng

    2014-04-01

    This study aimed to investigate the clinical significance of 3-dimensional (3D) reconstruction of peripancreatic vessels for patients with suspected pancreatic cancer (PC). A total of 89 patients with PC were included; 60 patients randomly underwent computed tomographic angiography. Based on the findings of 3D reconstruction of peripancreatic vessels, the appropriate method for individualized tumor resection was determined. These patients were compared with 29 conventionally treated patients with PC. The rate of visualization was 100% for great vessels around the pancreas. The detection rates for anterior superior pancreaticoduodenal artery, posterior superior pancreaticoduodenal artery, anterior inferior pancreaticoduodenal artery, posterior inferior pancreaticoduodenal artery, dorsal pancreatic artery, superior marginal arterial branch of the pancreatic head, anterior superior pancreaticoduodenal vein, posterior superior pancreaticoduodenal vein, anterior inferior pancreaticoduodenal vein, and posterior inferior pancreaticoduodenal vein were 86.6%, 85.0%, 76.6%, 71.6%, 91.6%, 53.3%, 61.6%, 55.0%, 43.3%, and 51.6%, respectively. Forty-three patients who had undergone 3D reconstruction underwent surgery. Of the 29 conventionally treated patients, 19 underwent surgery. The operative time, blood loss, length of hospital stay, and complication incidence of the 43 patients were superior to that of the 19 patients. A peripancreatic vascular reconstruction can reveal the vascular anatomy, variations of peripancreatic vascular, and tumor-induced vascular changes; the application of the simulation surgery platform could reduce surgical trauma and decrease operative time.

  20. Diagnosis of unsuspected facial fractures on routine head computerized tomographic scans in the unconscious multiply injured patient.

    PubMed

    Rehm, C G; Ross, S E

    1995-05-01

    This article assessed the value of routine head computerized axial tomographic (CT) scans for diagnosis of unsuspected facial fractures and its clinical implications in the multiply injured patient who is intubated, unconscious, or sedated at the time of initial assessment and requires a head CT scan to assess for brain injury. At a level I trauma center from June 1, 1992 to June 1, 1993 all intubated blunt trauma patients who required routine CT scan evaluation at initial assessment were studied prospectively. Routine scanning started at the foramen magnum and included the maxilla. Patients who died within the first 24 hours were excluded. The study population included 116 patients (85 male, 21 female) aged 12 to 85 years (mean, 28 years) with injury severity scores ranging from 1 to 50 (mean, 23). The mechanism of injury was: motor vehicle accidents (n = 74), motorcycling (n = 5), pedestrians accidents (n = 13), falls (n = 10), bicycling (n = 5), assaults (n = 8), and boating accident (n = 1). There were 19 suspected facial fractures; 18 required surgical repair. There were 27 unsuspected facial fractures; 13 required surgical care. Three suspected fractures were ruled out. Routine head CT scans to assess for brain injury in the multiply injured patient are also very useful in the diagnosis of unsuspected facial fractures, almost half of which will require surgical intervention.

  1. Comparison of standard- and low-tube voltage 320-detector row volume CT angiography in detection of intracranial aneurysms with digital subtraction angiography as gold standard.

    PubMed

    Sun, Gang; Ding, Juan; Lu, Yang; Li, Min; Li, Li; Li, Guo-ying; Zhang, Xu-ping

    2012-03-01

    The aim of this study was to prospectively assess the effect of low-tube voltage (80 kVp) 320-detector row volume computed tomographic (CT) angiography (L-VCTA) in the detection of intracranial aneurysms, with three-dimensional (3D) spin digital subtraction angiography (DSA) as the gold standard. Forty-eight patients with clinically suspected subarachnoid hemorrhages were divided into two groups. One group underwent L-VCTA and DSA, while the other group underwent conventional-tube voltage (120 kVp) volume CT angiography (C-VCTA) and DSA. Vascular enhancement, image quality, detection accuracy of aneurysms, and radiation dose were compared between the two groups. For objective image quality, the L-VCTA group had higher mean vessel attenuation, correlated with higher image noise and lower signal-to-noise ratio, than the C-VCTA group. For subjective image quality, there were no significant differences between the two groups regarding scores for arterial enhancement, depiction of small arterial detail, interference of venous structures, and overall image quality scores. The mean effective dose for the L-VCTA group was significantly lower than for the C-VCTA group (0.56 ± 0.25 vs 1.84 ± 0.002 mSv), with a reduction of radiation dose of 69.73%. With 3D DSA as the reference standard, the sensitivity, specificity, and accuracy in the L-VCTA and C-VCTA groups were 94.12%, 100%, 94.4% and 100%, 100%, and 100%, respectively. In both groups, there were significant correlations for maximum aneurysm diameter measurements between volume CT angiography and 3D DSA; no statistical difference in the mean maximum diameter of each aneurysm was measured between volume CT angiography and 3D DSA. L-VCTA is helpful in detecting intracranial aneurysms, with results similar to those of 3D DSA, but at a lower radiation dose than C-VCTA. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  2. Robotic digital subtraction angiography systems within the hybrid operating room.

    PubMed

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  3. 3.0Tesla magnetic resonance angiography (MRA) for comprehensive renal evaluation of living renal donors: pilot study with computerized tomography angiography (CTA) comparison.

    PubMed

    Gulati, Mittul; Dermendjian, Harout; Gómez, Ana M; Tan, Nelly; Margolis, Daniel J; Lu, David S; Gritsch, H Albin; Raman, Steven S

    2016-01-01

    Most living related donor (LRD) kidneys are harvested laparoscopically. Renal vascular anatomy helps determine donor suitability for laparoscopic nephrectomy. Computed tomography angiography (CTA) is the current gold standard for preoperative imaging; magnetic resonance angiography (MRA) offers advantages including lack of ionizing radiation and lower incidence of contrast reactions. We evaluated 3.0T MRA for assessing renal anatomy of LRDs. Thirty consecutive LRDs underwent CTA followed by 3.0T MRA. Data points included number and branching of vessels, incidental findings, and urothelial opacification. Studies were individually evaluated by three readers blinded to patient data. Studies were reevaluated in consensus with discrepancies revealed, and final consensus results were labeled "truth". Compared with consensus "truth", both computed tomography (CT) and magnetic resonance imaging were highly accurate for assessment of arterial and venous anatomy, although CT was superior for detection of late venous confluence as well as detection of renal stones. Both modalities were comparable in opacification of lower ureters and bladder; MRA underperformed CTA for opacification of upper urinary tracts. 3.0T MRA enabled excellent detection of comprehensive renal anatomy compared to CTA in LRDs. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Research on ionospheric tomography based on variable pixel height

    NASA Astrophysics Data System (ADS)

    Zheng, Dunyong; Li, Peiqing; He, Jie; Hu, Wusheng; Li, Chaokui

    2016-05-01

    A novel ionospheric tomography technique based on variable pixel height was developed for the tomographic reconstruction of the ionospheric electron density distribution. The method considers the height of each pixel as an unknown variable, which is retrieved during the inversion process together with the electron density values. In contrast to conventional computerized ionospheric tomography (CIT), which parameterizes the model with a fixed pixel height, the variable-pixel-height computerized ionospheric tomography (VHCIT) model applies a disturbance to the height of each pixel. In comparison with conventional CIT models, the VHCIT technique achieved superior results in a numerical simulation. A careful validation of the reliability and superiority of VHCIT was performed. According to the results of the statistical analysis of the average root mean square errors, the proposed model offers an improvement by 15% compared with conventional CIT models.

  5. Computerized detection of unruptured aneurysms in MRA images: reduction of false positives using anatomical location features

    NASA Astrophysics Data System (ADS)

    Uchiyama, Yoshikazu; Gao, Xin; Hara, Takeshi; Fujita, Hiroshi; Ando, Hiromichi; Yamakawa, Hiroyasu; Asano, Takahiko; Kato, Hiroki; Iwama, Toru; Kanematsu, Masayuki; Hoshi, Hiroaki

    2008-03-01

    The detection of unruptured aneurysms is a major subject in magnetic resonance angiography (MRA). However, their accurate detection is often difficult because of the overlapping between the aneurysm and the adjacent vessels on maximum intensity projection images. The purpose of this study is to develop a computerized method for the detection of unruptured aneurysms in order to assist radiologists in image interpretation. The vessel regions were first segmented using gray-level thresholding and a region growing technique. The gradient concentration (GC) filter was then employed for the enhancement of the aneurysms. The initial candidates were identified in the GC image using a gray-level threshold. For the elimination of false positives (FPs), we determined shape features and an anatomical location feature. Finally, rule-based schemes and quadratic discriminant analysis were employed along with these features for distinguishing between the aneurysms and the FPs. The sensitivity for the detection of unruptured aneurysms was 90.0% with 1.52 FPs per patient. Our computerized scheme can be useful in assisting the radiologists in the detection of unruptured aneurysms in MRA images.

  6. Arterial imaging in patients with lower extremity ischemia and diabetes mellitus.

    PubMed

    Pomposelli, Frank

    2010-09-01

    Precise, comprehensive imaging of the arterial circulation is the cornerstone of successful revascularization of the ischemic extremity in patients with diabetes mellitus. Arterial imaging is challenging in these patients because the disease is often multisegmental with a predilection for the distal tibial and peroneal arteries. Occlusive lesions and the arterial wall itself are often calcified and patients presenting with ischemic complications frequently have underlying renal insufficiency. Intra-arterial digital subtraction angiography (DSA), contrast enhanced magnetic resonance angiography (MRA), and more recently, computerized tomographic angiography (CTA) have been used as imaging modalities in lower extremity ischemia. Each has specific advantages and shortcomings in this patient population, which will be summarized and contrasted in this review. DSA is an invasive technique most often performed from a femoral arterial puncture and requires the injection of arterial contrast, which can occasionally cause allergic reactions. In patients with pre-existing renal insufficiency, contrast infusion can result in worsening renal failure; although usually self-limited, it may occasionally require hemodialysis, especially in patients with diabetes. However, DSA provides the highest degree of spatial resolution and image quality. It is also the only modality in which the diagnosis and treatment of arterial disease can be performed simultaneously. MRA is noninvasive, and when enhanced with gadolinium contrast injection provides arterial images of comparable quality to DSA and in some circumstances may uncover distal arterial targets not visualized on DSA. However, spatial resolution is inferior to DSA and erroneous interpretations due to acquisition artifacts are common. Specialized equipment and imaging techniques are necessary to minimize their occurrence in the distal lower extremity. In addition, due to the risk of inducing nephrogenic systemic fibrosis, gadolinium-enhanced MRA cannot be used in patients with renal insufficiency. CTA is noninvasive and rapidly performed, with better spatial resolution than MRA, but requires the largest volume of contrast infusion, exposes patients to high-doses of radiation, and is subject to interpretive error due to reconstruction artifacts especially in heavily calcified arteries, limiting its usefulness in many patients with diabetes. For patients in whom the planned intervention is a surgical bypass, DSA and MRA will provide high quality images of the lower extremity arterial anatomy. For patients in whom a catheter-based intervention is the likely treatment, a diagnostic DSA immediately followed by a catheter-based treatment in the same procedure is the preferred approach. In patients with pre-existing renal dysfunction, in which gadolinium-enhanced MRA is contraindicated, DSA or CTA can be performed. However, patients should have an infusion of intravenous normal saline solution or sodium bicarbonate before the procedure to reduce the incidence of contrast-induced nephropathy. Copyright © 2010. Published by Mosby, Inc.

  7. Computed Tomographic Angiography of the Pancreas in Cats with Chronic Diabetes Mellitus Compared to Normal Cats.

    PubMed

    Secrest, S; Sharma, A; Bugbee, A

    2018-03-02

    Diabetes mellitus (DM) is a common endocrinopathy in cats. No known diagnostic test or patient characteristic at the time of diagnosis can predict likely disease course, unlike in people in whom computed tomographic angiography (CTA) is used. No published data exist regarding the CTA appearance of the pancreas in cats with DM, and thus, it is unknown what if any CTA variables should be further assessed for associations with pancreatic endocrine function. A significant difference in pancreatic attenuation, volume, and size will be identified between normal cats and those with chronic DM on CTA. Ten healthy control cats and 15 cats with naturally occurring DM present for >12 months. Prospective cross-sectional study comparing pancreatic attenuation, enhancement pattern, size, volume, pancreatic volume-to-body weight ratio (V:BW), pancreatic arterial: portal phase ratio (A:P), time-to-arterial enhancement, and time-to-peak portal enhancement on CTA between sedated healthy control cats and those with chronic DM. The pancreas in cats with chronic DM was significantly larger, had higher volume, higher V:BW, and shorter time-to-peak portal enhancement on CTA when compared to normal cats. Peak portal enhancement time, pancreatic size, pancreatic volume, and V:BW can be used to differentiate normal sedated cats from those with chronic DM by CTA. These variables warrant further investigation to identify possible associations with endocrine function. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  8. Computed Tomography-Derived Fractional Flow Reserve in the Detection of Lesion-Specific Ischemia: An Integrated Analysis of 3 Pivotal Trials.

    PubMed

    Xu, Rende; Li, Chenguang; Qian, Juying; Ge, Junbo

    2015-11-01

    Invasive fractional flow reserve (FFR) is the gold standard for the determination of physiologic stenosis severity and the need for revascularization. FFR computed from standard acquired coronary computed tomographic angiography datasets (FFRCT) is an emerging technology which allows calculation of FFR using resting image data from coronary computed tomographic angiography (CCTA). However, the diagnostic accuracy of FFRCT in the evaluation of lesion-specific myocardial ischemia remains to be confirmed, especially in patients with intermediate coronary stenosis. We performed an integrated analysis of data from 3 prospective, international, and multicenter trials, which assessed the diagnostic performance of FFRCT using invasive FFR as a reference standard. Three studies evaluating 609 patients and 1050 vessels were included. The total calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FFRCT were 82.8%, 77.7%, 60.8%, 91.6%, and 79.2%, respectively, for the per-vessel analysis, and 89.4%, 70.5%, 69.7%, 89.7%, and 78.7%, respectively, for the per-patient analysis. Compared with CCTA alone, FFRCT demonstrated significantly improved accuracy (P < 0.001) in detecting lesion-specific ischemia. In patients with intermediate coronary stenosis, FFRCT remained both highly sensitive and specific with respect to the diagnosis of ischemia. In conclusion, FFRCT appears to be a reliable noninvasive alternative to invasive FFR, as it demonstrates high accuracy in the determination of anatomy and lesion-specific ischemia, which justifies the performance of additional randomized controlled trials to evaluate both the clinical benefits and the cost-effectiveness of FFRCT-guided coronary revascularization.

  9. Computerized Doppler Tomography and Spectrum Analysis of Carotid Artery Flow

    PubMed Central

    Morton, Paul; Goldman, Dave; Nichols, W. Kirt

    1981-01-01

    Contrast angiography remains the definitive study in the evaluation of atherosclerotic occlusive vascular disease. However, a safer technique for serial screening of symptomatic patients and for routine follow up is necessary. Computerized pulsed Doppler ultrasonic arteriography is a noninvasive technique developed by Miles6 for imaging lateral, antero-posterior and transverse sections of the carotid artery. We [ill] this system with new software and hardware to analyze the three-dimensional blood flow data. The system now provides information about the location of the occlusive process in the artery and a semi-quantitative evaluation of the degree of obstruction. In addition, we interfaced a digital signal analyzer to the system which permits spectrum analysis of the pulsed Doppler signal. This addition has allowed us to identify lesions which are not yet hemodynamically significant. ImagesFig. 2bFig. 2c

  10. Use of Coronary Computed Tomographic Angiography to Guide Management of Patients With Coronary Disease

    PubMed Central

    Williams, Michelle C.; Hunter, Amanda; Shah, Anoop S.V.; Assi, Valentina; Lewis, Stephanie; Smith, Joel; Berry, Colin; Boon, Nicholas A.; Clark, Elizabeth; Flather, Marcus; Forbes, John; McLean, Scott; Roditi, Giles; van Beek, Edwin J.R.; Timmis, Adam D.; Newby, David E.

    2016-01-01

    Background In a prospective, multicenter, randomized controlled trial, 4,146 patients were randomized to receive standard care or standard care plus coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to explore the consequences of CCTA-assisted diagnosis on invasive coronary angiography, preventive treatments, and clinical outcomes. Methods In post hoc analyses, we assessed changes in invasive coronary angiography, preventive treatments, and clinical outcomes using national electronic health records. Results Despite similar overall rates (409 vs. 401; p = 0.451), invasive angiography was less likely to demonstrate normal coronary arteries (20 vs. 56; hazard ratios [HRs]: 0.39 [95% confidence interval (CI): 0.23 to 0.68]; p < 0.001) but more likely to show obstructive coronary artery disease (283 vs. 230; HR: 1.29 [95% CI: 1.08 to 1.55]; p = 0.005) in those allocated to CCTA. More preventive therapies (283 vs. 74; HR: 4.03 [95% CI: 3.12 to 5.20]; p < 0.001) were initiated after CCTA, with each drug commencing at a median of 48 to 52 days after clinic attendance. From the median time for preventive therapy initiation (50 days), fatal and nonfatal myocardial infarction was halved in patients allocated to CCTA compared with those assigned to standard care (17 vs. 34; HR: 0.50 [95% CI: 0.28 to 0.88]; p = 0.020). Cumulative 6-month costs were slightly higher with CCTA: difference $462 (95% CI: $303 to $621). Conclusions In patients with suspected angina due to coronary heart disease, CCTA leads to more appropriate use of invasive angiography and alterations in preventive therapies that were associated with a halving of fatal and non-fatal myocardial infarction. (Scottish COmputed Tomography of the HEART Trial [SCOT-HEART]; NCT01149590) PMID:27081014

  11. Donor recruitment and selection for adult-to-adult living donor liver transplantation in urgent and elective circumstances.

    PubMed

    Ben-Haim, Menahem; Carmiel, Michal; Lubezky, Nir; Keidar, Rivka; Katz, Paulina; Blachar, Arye; Nimrod, Adi; Sorkine, Patrick; Oren, Ran; Klausner, Joseph M; Nakache, Richard

    2005-03-01

    Adult-to-adult living donor liver transplantation is becoming an alternative to cadaveric transplantation in urgent and elective settings. Donor selection crucially affects donor safety and recipient outcome. To present our algorithm of urgent and elective donor selection. Urgent selection is expeditious and protocol-based. Elective selection permits a comprehensive process. Both include medical, psychosocial and surgical-anatomic evaluations. Liver volumes and vascular anatomy are evaluated with computerized tomographic angiography. Informed consent is obtained after painstaking explanations. Independent institutional committees review and approve all cases. Between July 2003 and June 2004 we evaluated 43 potential live donors for 12 potential recipients (fulminant hepatic failure, n = 5; chronic end-stage liver disease, n = 6; primary graft non-function, n = 1). Thirty-three candidates (76%) were excluded due to blood type incompatibility (n = 14, 42%), incompatible anatomy (n = 8, 24%)--including problematic volume distribution (n = 2) or vascular anatomy (n = 6)--psychosocial issues (n = 4, 12%), or medical co-morbidity (n = 7, 22%). Five recipients (FHF, n = 4; chronic ESLD, n = 1) were successfully transplanted from living donors. In the acute setting, two patients (FHF, PGNF) died in the absence of an appropriate donor (cadaveric or living donor). In the elective group, one patient died of unexpected variceal bleeding and one received a cadaveric graft just before the planned living donor transplantation was performed. One candidate was transplanted overseas and two cases are scheduled. The ratio of compatibility for donation was 34% (10/29) for blood type-compatible candidates. Donor selection for living donor liver transplantation is a complex, labor-intensive multidisciplinary process. Most exclusions are due to blood type incompatibility or anatomic details. Psychosocial aspects of these donations warrant special attention.

  12. SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee: Endorsed by the North American Society for Cardiovascular Imaging (NASCI).

    PubMed

    Abbara, Suhny; Blanke, Philipp; Maroules, Christopher D; Cheezum, Michael; Choi, Andrew D; Han, B Kelly; Marwan, Mohamed; Naoum, Chris; Norgaard, Bjarne L; Rubinshtein, Ronen; Schoenhagen, Paul; Villines, Todd; Leipsic, Jonathon

    In response to recent technological advancements in acquisition techniques as well as a growing body of evidence regarding the optimal performance of coronary computed tomography angiography (coronary CTA), the Society of Cardiovascular Computed Tomography Guidelines Committee has produced this update to its previously established 2009 "Guidelines for the Performance of Coronary CTA" (1). The purpose of this document is to provide standards meant to ensure reliable practice methods and quality outcomes based on the best available data in order to improve the diagnostic care of patients. Society of Cardiovascular Computed Tomography Guidelines for the Interpretation is published separately (2). The Society of Cardiovascular Computed Tomography Guidelines Committee ensures compliance with all existing standards for the declaration of conflict of interest by all authors and reviewers for the purpose ofclarity and transparency. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bargellini, Irene, E-mail: irenebargellini@hotmail.com; Turini, Francesca; Bozzi, Elena

    To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-timemore » X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.« less

  14. Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou Chuan; Chan, H.-P.; Sahiner, Berkman

    2007-12-15

    The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix atmore » multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.« less

  15. Systemic Artery to Pulmonary Vein Fistula After Right Upper Lobectomy Demonstrated by 4-Dimensional Flow Magnetic Resonance Imaging.

    PubMed

    Legras, Antoine; Azarine, Arshid; Poitier, Bastien; Messas, Emmanuel; Le Pimpec-Barthes, Françoise

    2017-08-01

    Postoperative systemic artery to pulmonary vein fistula is very rare. In this report, we describe an exceptional condition of both intrapulmonary arteriovenous fistula and systemic artery to pulmonary vein fistula, involving all right hemithoracic systemic arteries, inducing left-to-left shunt. This condition was responsible for heart failure, 24 years after a right upper lobectomy for inflammatory tumor. Investigations included computed tomographic angiography, arteriography, and four-dimensional flow magnetic resonance imaging. Differential diagnosis and management are discussed. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Successful Recanalization of Acute Superior Mesenteric Artery Thromboembolic Occlusion by a Combination of Intraarterial Thrombolysis and Mechanical Thrombectomy with a Carotid Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelenak, Kamil, E-mail: zelenak@unm.sk; Sinak, Igor; Janik, Jan

    2013-06-15

    Acute superior mesenteric artery (SMA) occlusion is a life-threatening disease, and acute intestinal ischemia develops from the sudden decrease in perfusion to the intestines. The key to saving the patient's life is early diagnosis, and prompt revascularization of the SMA can prevent intestinal infarction and decrease the risk of bowel segment necrosis. Computed tomographic angiography may be useful for rapid diagnosis. We report recanalization of an SMA occlusion in an 80-year-old man with a combination of intraarterial thrombolysis and mechanical thrombectomy with a carotid filter.

  17. Successful Management of Neobladder Variceal Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atwal, Dinesh; Chatterjee, Kshitij, E-mail: kchatterjee@uams.edu; Osborne, Scott

    Hematuria from a neobladder can occur due to a variety of pathologies including tumors, stones, and fistulas. Variceal bleeding in a neobladder is a very rare condition with only one case reported in literature. We present a case of a patient with cirrhosis and portal hypertension and an ileocolic orthotopic neobladder presenting with hematuria. Computed tomographic angiography showed dilated varices around the neobladder which were successfully embolized. To the best of our knowledge, this is the first report case of variceal bleeding in a neobladder successfully managed with the combination of TIPS (transjugular intrahepatic portosystemic shunt) procedure and embolization.

  18. Arteriovenous malformation of the external ear: a clinical assessment with a scoping review of the literature.

    PubMed

    Kim, Shin Hye; Han, Seung Hoon; Song, Yoonjae; Park, Chang Sik; Song, Jae-Jin

    Auricular Arteriovenous Malformation of the external ear is a rarely encountered disease; in particular, arteriovenous malformation arising from the auricle, with spontaneous bleeding, has seldom been reported. In the current study, we report an unusual case of late-onset auricular arteriovenous malformation originating from the posterior auricular artery that was confirmed by computed tomographic angiography. The case was successfully managed by pre-surgical intravascular embolization followed by total lesion excision. Prompted by this case, we also present a scoping review of the literature. A case of a 60 year-old man with right auricular arteriovenous malformation treated in our tertiary care center, and 52 patients with auricular arteriovenous malformation described in 10 case reports and a retrospective review are presented. Auricular arteriovenous malformation can manifest as swelling of the ear, pulsatile tinnitus, pain, and/or bleeding. On physical examination, a pulsatile swelling and/or a tender mass is evident. When arteriovenous malformation is suspected, the lesions should be visualized using imaging modalities that optimally detect vascular lesions, and managed via embolization, mass excision, or auricular resection. Effectiveness of the various diagnostic methods used and the treatment outcomes were analyzed. Various imaging modalities including Doppler sonography, computed tomographic angiography, magnetic resonance angiography, and/or transfemoral cerebral angiography were used to diagnose 38 cases reported in the literature. In another 15 cases, no imaging was performed; treatment was determined solely by physical examination and auscultation. Of the total of 53 cases, 12 were not treated (their symptoms were merely observed) whereas 20 underwent therapeutic embolization. In total, 32 patients, including 1 patient who was not treated and 10 with persistent or aggravated arteriovenous malformation after previous embolization, underwent mass excision or auricular resection depending on the extent of the lesion. No major postoperative complication was recorded. The postoperative follow-up duration varied from 1 month to 19 years, and only one case of unresectable, residual cervicofacial arteriovenous malformation was recorded. Auricular arteriovenous malformation is a rarely encountered disease, but should be suspected if a patient presents with a swollen ear and pulsatile tinnitus. Appropriate imaging is essential for diagnosis and evaluation of the extent of disease. As embolization affords only relatively poor control, total surgical removal of the vascular mass is recommended. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. TomoPhantom, a software package to generate 2D-4D analytical phantoms for CT image reconstruction algorithm benchmarks

    NASA Astrophysics Data System (ADS)

    Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.

    2018-01-01

    In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.

  20. Monocyte Chemoattractant Protein-1 as a Predictor of Coronary Atherosclerosis in Patients Receiving Coronary Angiography.

    PubMed

    Mahler, Simon A; Register, Thomas C; Riley, Robert F; D'Agostino, Ralph B; Stopyra, Jason P; Miller, Chadwick D

    2018-06-01

    Animal studies suggest that monocyte chemoattractant protein-1 (MCP-1) is a promising biomarker for coronary artery atherosclerosis (CAA), but human studies have been inconclusive. To determine potential relationships between plasma MCP-1 and CAA in patients with acute chest pain. A secondary analysis of 150 patients enrolled in emergency department chest pain risk stratification clinical investigations was conducted. Participants with stored blood and known coronary phenotypes (determined by coronary angiography) were selected using stratified randomization such that 50 patients were included into 3 groups: (1) no angiographic evidence of CAA, (2) nonobstructive CAA, and (3) obstructive CAA (stenosis ≥ 70%). Plasma MCP-1 levels were determined by enzyme-linked immunosorbent assay. The association between MCP-1 and obstructive CAA or any CAA was modeled using logistic regression. Variables in the unreduced model included age, sex, race, prior diagnosis of CAA or acute coronary syndrome, hyperlipidemia, hypertension, diabetes, smoking, and cardiac troponin I measurement. Among the 150 participants, 65.3% (98/150) had invasive coronary angiography and 34.7% (52/150) had coronary computed tomographic angiography. Myocardial infarction occurred in 27.3% (41/150) and coronary revascularization occurred in 26% (39/150) of the participants. Each 10 pg/mL increase in MCP-1 measurement was associated with an odds ratio of 1.12 (95% confidence interval, 1.06-1.19) for obstructive CAA. MCP-1 remained a significant predictor of obstructive CAA and any CAA after adjustment for age, sex, race, traditional cardiac risk factors, and cardiac troponin I. MCP-1 is independently associated with CAA among emergency department patients with chest pain.

  1. Utilization of Cone-Beam Computed Tomographic Angiography in Planning for Gamma Knife Radiosurgery of Arteriovenous Malformations: A Case Series and Early Report

    PubMed Central

    Safain, Mina G.; Rahal, Jason P.; Raval, Ami; Rivard, Mark J.; Mignano, John; Wu, Julian; Malek, Adel M.

    2014-01-01

    Background The effectiveness of Gamma Knife radiosurgery (GKR) for cerebral arteriovenous malformations (AVM) is predicated on inclusion of the entire nidus while excluding normal tissue. As such, GKR may be limited by the resolution and accuracy of the imaging modality used in targeting. Objective We present the first case series to demonstrate the feasibility of utilizing ultra-high-resolution C-arm cone beam computed tomography angiography (CBCT-A) in AVM targeting. Methods From June 2009 to June 2013, CBCT-A was utilized for targeting of all patients with AVMs treated with GKR at our institution. Patients underwent Leksell stereotactic head frame placement followed by catheter-based biplane 2-D digital subtraction angiography (DSA), 3-D rotational angiography (3DRA), as well as CBCT-A. The CBCT-A dataset was used for stereotactic planning for GKR. Patients were followed up at 1, 3, 6, and 12 months, and then annually thereafter. Results CBCT-A-based targeting was used in twenty-two consecutive patients. CBCT-A provided detailed spatial resolution and sensitivity of nidal angioarchitecture enabling treatment. The average radiation dose to the margin of the AVM nidus corresponding to the 50% percent isodose line was 15.6 Gy. No patient had treatment-associated hemorrhage. At early follow-up (mean=16 months), 84% of patients had a decreasing or obliterated AVM nidus. Conclusion CBCT-A-guided radiosurgery is feasible and useful because it provides sufficient detailed resolution and sensitivity for imaging brain AVMs. PMID:24584136

  2. Automated segmentation of foveal avascular zone in fundus fluorescein angiography.

    PubMed

    Zheng, Yalin; Gandhi, Jagdeep Singh; Stangos, Alexandros N; Campa, Claudio; Broadbent, Deborah M; Harding, Simon P

    2010-07-01

    PURPOSE. To describe and evaluate the performance of a computerized automated segmentation technique for use in quantification of the foveal avascular zone (FAZ). METHODS. A computerized technique for automated segmentation of the FAZ using images from fundus fluorescein angiography (FFA) was applied to 26 transit-phase images obtained from patients with various grades of diabetic retinopathy. The area containing the FAZ zone was first extracted from the original image and smoothed by a Gaussian kernel (sigma = 1.5). An initializing contour was manually placed inside the FAZ of the smoothed image and iteratively moved by the segmentation program toward the FAZ boundary. Five tests with different initializing curves were run on each of 26 images to assess reproducibility. The accuracy of the program was also validated by comparing results obtained by the program with the FAZ boundaries manually delineated by medical retina specialists. Interobserver performance was then evaluated by comparing delineations from two of the experts. RESULTS. One-way analysis of variance indicated that the disparities between different tests were not statistically significant, signifying excellent reproducibility for the computer program. There was a statistically significant linear correlation between the results obtained by automation and manual delineations by experts. CONCLUSIONS. This automated segmentation program can produce highly reproducible results that are comparable to those made by clinical experts. It has the potential to assist in the detection and management of foveal ischemia and to be integrated into automated grading systems.

  3. Coronary Plaque Morphology and the Anti-Inflammatory Impact of Atorvastatin: A Multicenter 18F-Fluorodeoxyglucose Positron Emission Tomographic/Computed Tomographic Study.

    PubMed

    Singh, Parmanand; Emami, Hamed; Subramanian, Sharath; Maurovich-Horvat, Pal; Marincheva-Savcheva, Gergana; Medina, Hector M; Abdelbaky, Amr; Alon, Achilles; Shankar, Sudha S; Rudd, James H F; Fayad, Zahi A; Hoffmann, Udo; Tawakol, Ahmed

    2016-12-01

    Nonobstructive coronary plaques manifesting high-risk morphology (HRM) associate with an increased risk of adverse clinical cardiovascular events. We sought to test the hypothesis that statins have a greater anti-inflammatory effect within coronary plaques containing HRM. In this prospective multicenter study, 55 subjects with or at high risk for atherosclerosis underwent 18 F-fluorodeoxyglucose positron emission tomographic/computed tomographic imaging at baseline and after 12 weeks of treatment with atorvastatin. Coronary arterial inflammation ( 18 F-fluorodeoxyglucose uptake, expressed as target-to-background ratio) was assessed in the left main coronary artery (LMCA). While blinded to the PET findings, contrast-enhanced computed tomographic angiography was performed to characterize the presence of HRM (defined as noncalcified or partially calcified plaques) in the LMCA. Arterial inflammation (target-to-background ratio) was higher in LMCA segments with HRM than those without HRM (mean±SEM: 1.95±0.43 versus 1.67±0.32 for LMCA with versus without HRM, respectively; P=0.04). Moreover, atorvastatin treatment for 12 weeks reduced target-to-background ratio more in LMCA segments with HRM than those without HRM (12 week-baseline Δtarget-to-background ratio [95% confidence interval]: -0.18 [-0.35 to -0.004] versus 0.09 [-0.06 to 0.26]; P=0.02). Furthermore, this relationship between coronary plaque morphology and change in LMCA inflammatory activity remained significant after adjusting for baseline low-density lipoprotein and statin dose (β=-0.27; P=0.038). In this first study to evaluate the impact of statins on coronary inflammation, we observed that the anti-inflammatory impact of statins is substantially greater within coronary plaques that contain HRM features. These findings suggest an additional mechanism by which statins disproportionately benefit individuals with more advanced atherosclerotic disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00703261. © 2016 The Authors.

  4. The Influence of a Pfannenstiel Scar on Venous Anatomy of the Lower Abdominal Wall and Implications for Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction.

    PubMed

    Kim, So Young; Lee, Kyeong-Tae; Mun, Goo-Hyun

    2017-03-01

    A Pfannenstiel incision involves the obstruction of superficial venous pathways and functional diversion of flow through alternative pathways and adjacent vessels. This study investigated the effect of a prior Pfannenstiel incision on venous anatomy of the lower abdominal wall; specifically, the superficial inferior epigastric vein (SIEV), using computed tomographic angiography. A case-control study was performed of 50 patients with Pfannenstiel scars and 50 age-matched, body mass index-matched control patients without Pfannenstiel scars. The authors compared the number of direct/indirect and total communications between the SIEV and deep inferior epigastric artery perforator (DIEP) venae comitantes, midline crossover, and other SIEV-related anatomical changes by using computed tomographic angiography. Flap-related clinical outcomes and donor-site-related complications were also assessed. The median number of direct and total communications between the SIEV and DIEP venae comitantes in the study group was greater than in the control group. The percentage of SIEVs having more than two branching patterns per hemiabdomen was significantly higher in the study group than in the control group. The study group also showed a significantly lower rate of fat necrosis compared with the control group (p = 0.03). The rate of donor-site seroma was significantly higher in the study group. This study suggests that the presence of a Pfannenstiel scar may promote the development of direct and total communications between the SIEV and DIEP venae comitantes and branching within the SIEV in the lower abdominal wall, which may facilitate venous drainage of adipose tissue in DIEP flap breast reconstruction. Risk, II.

  5. Computed tomographic angiography study of the relationship between the lingual artery and lingual markers in patients with obstructive sleep apnoea.

    PubMed

    Hou, T-N; Zhou, L-N; Hu, H-J

    2011-06-01

    To determine the relationship between the lingual artery and lingual markers for preoperative evaluation of the lingual artery in patients with obstructive sleep apnoea/hypopnoea syndrome (OSAHS). A 16-section computed tomographic angiography (CTA) of the lingual artery was performed in 87 inpatient cases with OSAHS, from December 2007 to May 2009. The course of the lingual artery and the anatomic relationship between the lingual artery and the lingual markers were analyzed using CTA imaging. The course of the lingual artery with the tongue in a resting position was similar to that of the Big Dipper constellation (Plough) in the sagittal view of CTA imaging. The first segment of the lingual artery declined approximately 19.27 ± 5.24 mm, the middle segment of the lingual artery was forward approximately 19.30 ± 6.79 mm, and the ascending segment of the lingual artery rose approximately 52.49 ± 10.98 mm. The entry point where the lingual artery entered into the tongue was adjacent to the tip of the greater horn of the hyoid bone. The relationship between the second segment of the lingual artery and the greater horn of the hyoid bone was relatively steady with the tongue in whatever position. The interval between the bilateral greater horn of the hyoid bone equalled that between the bilateral lingual arteries. Recognizing some lingual markers in the patients with OSAHS, such as the greater horn of the hyoid bone, foramen cecum, circumvallate papilla, lingual vein and tongue midline, may facilitate the surgeon's ability to define the course of the lingual artery accurately in the treatment of OSAHS. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Extended supraclavicular fasciocutaneous island flap based on the transverse cervical artery for head and neck reconstruction after cancer ablation.

    PubMed

    Chen, Wei-Liang; Zhang, Da-ming; Yang, Zhao-hui; Huang, Zhi-quan; Wang, Jian-guang; Zhang, Bin; Li, Jing-song

    2010-10-01

    This clinical study assessed a pedicled supraclavicular fasciocutaneous island flap (SFIF) based on the transverse cervical artery that was extended to include shoulder skin for reconstructing the head and neck. Pedicled SFIFs extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery were designed for 24 patients with defects of the head and neck after cancer ablation. Preoperative 3-dimensional computed tomographic angiography was performed in all patients. The patients consisted of 15 men and 9 women ranging in age from 24 to 73 years. The primary lesions included squamous cell carcinoma of the tongue, buccal mucosa, floor of the mouth, oropharynx, palate, and lower gingiva. Three-dimensional computed tomographic angiography showed that the transverse cervical artery arose from the thyrocervical trunk in 13 cases and from the subclavian artery in 11 cases. The diameter of the artery ranged from 0.15 to 0.24 cm. The size of flaps ranged from 4 × 8 cm to 6 × 12 cm, and the mean length of the vascular pedicle was approximately 18.5 cm. Of the flaps, 23 survived completely, for a success rate of 95.8%. Three patients underwent radiotherapy, and the follow-up period ranged from 3 to 12 months. One patient died of local tumor recurrence, and cervical recurrences developed in 3 patients. An SFIF extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery is a useful, viable option for defects of the head and neck after cancer ablation. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Impact of clinical presentation and pretest likelihood on the relation between calcium score and computed tomographic coronary angiography.

    PubMed

    van Werkhoven, Jacob M; de Boer, Stephanie M; Schuijf, Joanne D; Cademartiri, Filippo; Maffei, Erica; Jukema, J Wouter; Boogers, Mark J; Kroft, Lucia J; de Roos, Albert; Bax, Jeroen J

    2010-12-15

    The purpose of the present study was to assess the impact of clinical presentation and pretest likelihood on the relation between coronary calcium score (CCS) and computed tomographic coronary angiography (CTA) to determine the role of CCS as a gatekeeper to CTA in patients presenting with chest pain. In 576 patients with suspected coronary artery disease (CAD), CCS and CTA were performed. CCS was categorized as 0, 1 to 400, and >400. On CT angiogram the presence of significant CAD (≥50% luminal narrowing) was determined. Significant CAD was observed in 14 of 242 patients (5.8%) with CCS 0, in 94 of 260 patients (36.2%) with CCS 1 to 400, and in 60 of 74 patients (81.1%) with CCS >400. In patients with CCS 0, prevalence of significant CAD increased from 3.9% to 4.1% and 14.3% in nonanginal, atypical, and typical chest pain, respectively, and from 3.4% to 3.9% and 27.3% with a low, intermediate, and high pretest likelihood, respectively. In patients with CCS 1 to 400, prevalence of significant CAD increased from 27.4% to 34.7% and 51.7% in nonanginal, atypical, and typical chest pain, respectively, and from 15.4% to 35.6% and 50% in low, intermediate, and high pretest likelihood, respectively. In patients with CCS >400, prevalence of significant CAD on CT angiogram remained high (>72%) regardless of clinical presentation and pretest likelihood. In conclusion, the relation between CCS and CTA is influenced by clinical presentation and pretest likelihood. These factors should be taken into account when using CCS as a gatekeeper for CTA. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. Costs and clinical outcomes in individuals without known coronary artery disease undergoing coronary computed tomographic angiography from an analysis of Medicare category III transaction codes.

    PubMed

    Min, James K; Shaw, Leslee J; Berman, Daniel S; Gilmore, Amanda; Kang, Ning

    2008-09-15

    Multidetector coronary computed tomographic angiography (CCTA) demonstrates high accuracy for the detection and exclusion of coronary artery disease (CAD) and predicts adverse prognosis. To date, opportunity costs relating the clinical and economic outcomes of CCTA compared with other methods of diagnosing CAD, such as myocardial perfusion single-photon emission computed tomography (SPECT), remain unknown. An observational, multicenter, patient-level analysis of patients without known CAD who underwent CCTA or SPECT was performed. Patients who underwent CCTA (n = 1,938) were matched to those who underwent SPECT (n = 7,752) on 8 demographic and clinical characteristics and 2 summary measures of cardiac medications and co-morbidities and were evaluated for 9-month expenditures and clinical outcomes. Adjusted total health care and CAD expenditures were 27% (p <0.001) and 33% (p <0.001) lower, respectively, for patients who underwent CCTA compared with those who underwent SPECT, by an average of $467 (95% confidence interval $99 to $984) for CAD expenditures per patient. Despite lower total health care expenditures for CCTA, no differences were observed for rates of adverse cardiovascular events, including CAD hospitalizations (4.2% vs 4.1%, p = NS), CAD outpatient visits (17.4% vs 13.3%, p = NS), myocardial infarction (0.4% vs 0.6%, p = NS), and new-onset angina (3.0% vs 3.5%, p = NS). Patients without known CAD who underwent CCTA, compared with matched patients who underwent SPECT, incurred lower overall health care and CAD expenditures while experiencing similarly low rates of CAD hospitalization, outpatient visits, myocardial infarction, and angina. In conclusion, these data suggest that CCTA may be a cost-efficient alternative to SPECT for the initial coronary evaluation of patients without known CAD.

  9. Lidocaine bolus may facilitate computed tomographic coronary angiography in patients with frequent premature ventricular contractions

    PubMed Central

    Jastrzębski, Jan; Kępka, Cezary; Kruk, Mariusz; Demkow, Marcin; Kalińczuk, Łukasz; Wolny, Rafał; Ciszewski, Michał; Michałowska, Ilona; Witkowski, Adam

    2013-01-01

    Introduction Heart rate irregularities are the major limitations of computed tomographic coronary angiography (CTCA) due to severe motion artifacts. Aim To evaluate the safety and efficacy of a lidocaine intravenous bolus in preserving good image quality by the transient suppression of premature ventricular contractions (PVC) during the CTCA scan. Material and methods The study group comprised 67 consecutive patients with sinus rhythm and numerous PVC scheduled for CTCA. Intravenous boluses of 25–50 mg lidocaine were given after calcium score assessment and immediately before CTCA. The control group comprised 67 patients with sinus rhythm without PVC matched according to the body mass index (BMI), age, sex, and calcium score. All coronary vessel segments were assessed for image quality and presence of significant stenosis. Results As compared with calcium score assessment, after administration of lidocaine and during the CTCA scan PVC were completely suppressed in 22 (40%), reduced in 10 (18%), unchanged in 18 (32%), and intensified in 5 (10%) patients. Overall, there were 32 (58%) patients with sinus rhythm during CTCA as compared with only 11 (20%) patients free from PVC during calcium score assessment (p < 0.001). Image quality in 871 coronary segments including both the study group and control patients was worse in patients with PVC (p < 0.0001). However, there was no statistically significant difference in the number of patients with at least one segment of non-diagnostic quality (6% vs. 12%, p = 0.36; respectively). Conclusions Single lidocaine bolus given prior to CTCA is safe, may temporarily eliminate or reduce the intensity of arrhythmia, and hence results in improved quality of CTCA in patients with numerous PVC. PMID:24570719

  10. Ontario multidetector computed tomographic coronary angiography study: field evaluation of diagnostic accuracy.

    PubMed

    Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron

    2011-06-13

    Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.

  11. Safety of a rapid diagnostic protocol with accelerated stress testing.

    PubMed

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  12. High-pitch Helical Dual-source Computed Tomographic Pulmonary Angiography: Comparing Image Quality in Inspiratory Breath-hold and During Free Breathing.

    PubMed

    Ajlan, Amr M; Binzaqr, Salma; Jadkarim, Dalia A; Jamjoom, Lamia G; Leipsic, Jonathon

    2016-01-01

    The purpose of this study was to compare qualitative and quantitative image parameters of dual-source high-pitch helical computed tomographic pulmonary angiography (CTPA) in breath-holding (BH) versus free-breathing (FB) patients. Ninety-nine consented patients (61 female individuals; mean age±SD, 49±18.7 y) were randomized into BH (n=45) versus FB (n=54) high-pitch helical CTPA. Patient characteristics and CTPA radiation doses were analyzed. Two readers assessed for pulmonary embolism (PE), transient interruption of contrast, and respiratory and cardiac motion. The readers used a subjective 3-point scale to rate the pulmonary artery opacification and lung parenchymal appearance. A single reader assessed mean pulmonary artery signal intensity, noise, contrast, signal to noise ratio, and contrast to noise ratio. PE was diagnosed in 16% BH and 19% FB patients. CTPAs of both groups were of excellent or acceptable quality for PE evaluation and of similar mean radiation doses (1.3 mSv). Transient interruption of contrast was seen in 5/45 (11%) BH and 5/54 (9%) FB patients (not statistically significant, P=0.54). No statistically significant difference was noted in cardiac, diaphragmatic, and lung parenchymal motion. Lung parenchymal assessment was excellent in all cases, except for 5/54 (9%) motion-affected FB cases with acceptable quality (statistically significant, P=0.03). No CTPA was considered nondiagnostic by any of the readers. No objective image quality differences were noted between both groups (P>0.05). High-pitch helical CTPA acquired during BH or in FB yields comparable image quality for the diagnosis of PE and lung pathology, with low radiation exposure. Only a modest increase in lung parenchymal artifacts is encountered in FB high-pitch helical CTPA.

  13. Subclinical atherosclerosis detected by coronary computed tomographic angiography in Qatar: a comparison between Qataris and south Asian migrants.

    PubMed

    Schulman-Marcus, Joshua; Heo, Ran; Gransar, Heidi; Suwaidi, Jassim Al; Alkuwari, Maryam; Elmore, Kimberly; Gomez, Mille J; Jayyousi, Amin; Zirie, Mahmoud; Min, James K; Peña, Jessica M

    2017-06-01

    There are limited data regarding subclinical atherosclerosis in Middle Eastern countries. We aimed to describe and compare coronary computed tomographic angiography (CCTA) findings in Qatari native and South Asian migrants at increased risk of coronary artery disease (CAD). We performed CCTA in 251 consecutive volunteers (126 South Asian, 125 Qatari, mean age 50.0 ± 7.3 years, 27.1% female) at increased risk of cardiovascular disease. Given differences in baseline risk factors, we employed propensity score matching to create a cohort of 162 subjects for comparative analyses. We compared CAD severity, extent, plaque morphology, adverse plaque characteristics, and quantitative measures of atherosclerotic burden in both subgroups. After matching, no CAD was seen in 58.0% of South Asians and 49.4% of Qataris (p = 0.3), while obstructive CAD (≥50% luminal stenosis) was present in 40.7% of South Asians and 49.4% of Qataris (p = 0.3). There was a high prevalence of adverse plaque characteristics in both ethnicities, particularly positive remodeling. South Asians had significantly smaller vessel and lumen volumes, but the percent aggregate plaque volumes were not significantly different (2.9 ± 6.3% vs. 3.8 ± 8.0%, p = 0.4). In this first study of CCTA findings performed in a Middle Eastern country, we observed a high prevalence of obstructive CAD in a middle-aged cohort. There were no significant differences in CCTA findings between Qataris and South Asians after adjustment for clinical risk factors. Future studies are needed to identify patterns of coronary atherosclerosis by CCTA in non-European populations where cardiovascular disease is increasingly prevalent.

  14. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    PubMed

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Microdose computed tomographic cardiac angiography in normal cats.

    PubMed

    Rodriguez, Kiira T; O'Brien, Mauria A; Hartman, Susan K; Mulherin, Allison C; McReynolds, Casie J; McMichael, Maureen; Rapoport, Gregg; O'Brien, Robert T

    2014-03-01

    To determine if microdose contrast-enhanced multi-detector computed tomographic angiography (MDCTA) allows characterization of cardiac chambers in lightly sedated normal cats. Seven healthy domestic cats. Lightly sedated normal cats were imaged pre-contrast and with microdose (0.22 ml/kg of non-ionic iodinated contrast medium, 300 mg I/ml) triple-phase MDCTA in a motion restriction device. On pre-contrast images, the aorta (median: 52.43 Hounsfield units [HU], range 27.35-76.74 HU) was outlined by significantly (p = 0.015) lower attenuating periaortic fat (-66.16 HU, -42.62 to -92.77 HU). On post-contrast images, median peak contrast enhancement in the right ventricle (111.77 HU, 36.09-141.60 HU) was achieved in 3.1 s (range 2.9-7.3 s), in the aorta (149.30 HU, 99.43-319.60 HU) and left atrium (180.83 HU, 88.53-266.84 HU) in 6.4 s (range 5.6-7.7 s) and in the left ventricle (147.89 HU, 57.23-245.77 HU) in 7.10 s (range 6.2-11.2 s). Significantly higher attenuation was measured between all chambers and walls, the right ventricular lumen and interventricular septum (median ratio 53.78 HU, range 0.21-83.20 HU), left ventricular lumen and left ventricular free wall (89.32 HU, 38.81-185.95 HU) and aorta and periaortic fat (190.43 HU, 143.22-425.44 HU) on post-contrast images. Sufficient biological contrast is available on survey CT to discriminate between the aorta and the left atrium, and microdose MDCTA provides sufficient contrast enhancement for adequate visualization of the heart chambers in normal cats. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Radiation dose to patients and image quality evaluation from coronary 256-slice computed tomographic angiography

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Kuang; Wu, Tung-Hsin; Yang, Ching-Ching; Tsai, Chia-Jung; Lee, Jason J. S.

    2010-07-01

    The aim of this study is to assess radiation dose and the corresponding image quality from suggested CT protocols which depends on different mean heart rate and high heart rate variability by using 256-slice CT. Fifty consecutive patients referred for a cardiac CT examination were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on a 256-slice CT scanner with one of five different protocols: retrospective ECG-gating (RGH) with full dose exposure in all R-R intervals (protocol A), RGH of 30-80% pulsing window with tube current modulation (B), RGH of 78±5% pulsing window with tube current modulation (C), prospective ECG-triggering (PGT) of 78% R-R interval with 5% padding window (D) and PGT of 78% R-R interval without padding window (E). Radiation dose parameters and image quality scoring were determined and compared. In this study, no significant differences were found in comparison on image quality of the five different protocols. Protocol A obtained the highest radiation dose comparing with those of protocols B, C, D and E by a factor of 1.6, 2.4, 2.5 and 4.3, respectively ( p<0.001), which were ranged between 2.7 and 11.8 mSv. The PGT could significantly reduce radiation dose delivered to patients, as compared to the RGH. However, the use of PGT has limitations and is only good in assessing cases with lower mean heart rate and stable heart rate variability. With higher mean heart rate and high heart rate variability circumstances, the RGH within 30-80% of R-R interval pulsing window is suggested as a feasible technique for assessing diagnostic performance.

  17. Rapid prototyping in aortic surgery.

    PubMed

    Bangeas, Petros; Voulalas, Grigorios; Ktenidis, Kiriakos

    2016-04-01

    3D printing provides the sequential addition of material layers and, thus, the opportunity to print parts and components made of different materials with variable mechanical and physical properties. It helps us create 3D anatomical models for the better planning of surgical procedures when needed, since it can reveal any complex anatomical feature. Images of abdominal aortic aneurysms received by computed tomographic angiography were converted into 3D images using a Google SketchUp free software and saved in stereolithography format. Using a 3D printer (Makerbot), a model made of polylactic acid material (thermoplastic filament) was printed. A 3D model of an abdominal aorta aneurysm was created in 138 min, while the model was a precise copy of the aorta visualized in the computed tomographic images. The total cost (including the initial cost of the printer) reached 1303.00 euros. 3D imaging and modelling using different materials can be very useful in cases when anatomical difficulties are recognized through the computed tomographic images and a tactile approach is demanded preoperatively. In this way, major complications during abdominal aorta aneurysm management can be predicted and prevented. Furthermore, the model can be used as a mould; the development of new, more biocompatible, less antigenic and individualized can become a challenge in the future. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    PubMed

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. [Comparative evaluation of ultrasonography, computerized tomography, angiography and lipiodol CT in defining extent of hepatocarcinoma. A multicenter study].

    PubMed

    Dalla Palma, L; Pozzi Mucelli, R; Sponza, M; Bartolozzi, C; De Santis, M; Gandini, G; Mannella, P; Matricardi, L; Rossi, C; Simonetti, G

    1995-03-01

    The authors report the results of a multicentric trial on hepatocellular carcinoma (HCC) patients, whose lesions were confirmed with biopsy or by high (> 400 ng/ml) alpha-fetoprotein levels. The series consisted of 149 patients examined in 8 different centers and submitted to ultrasonography (US), Computed Tomography (CT) before and after contrast agent administration, angiography and Lipiodol CT. According to lesion size and number, the patients were divided with each imaging modality into three groups: a) group 1: unifocal HCC < 5 cm diameter; b) group 2: multifocal HCC with 2-3 nodules and/or tumor mass < 80 ml; c) multifocal HCC with more than 3 nodules (with total tumor mass not exceeding 40% of liver volume) or with total tumor mass > 80 ml. In 77 patients all the examinations were available for comparison. US and CT diagnosed more patients as belonging to group 1 than angiography and Lipiodol CT, while more patients were classified as groups 2 and 3 with angiography and Lipiodol CT, meaning that US and CT may understage some HCC cases (about 15%) because they show a lower number of nodules. This observation was confirmed by the direct comparison between US and Lipiodol CT (in 114 patients), CT and Lipiodol CT (in 103 patients) and angiography and Lipiodol CT (in 116 patients). US and Lipiodol CT were in disagreement in 18 cases, CT and Lipiodol CT in 16 cases and angiography and Lipiodol CT in 13 cases. In most of these cases, Lipiodol CT showed more lesions than the other techniques. The size of the undetected lesions was small, ranging few mm to 2 cm in nearly all cases. To conclude, the results of this multicentric trial show that Lipiodol CT is a fundamental tool to evaluate HCC extent. In contrast, conventional CT appeared not to add any significant piece of information and can therefore be excluded from the diagnostic protocol of HCC.

  20. Potential impact of clinical use of noninvasive FFRCT on radiation dose exposure and downstream clinical event rate.

    PubMed

    Bilbey, Nicolas; Blanke, Philipp; Naoum, Christopher; Arepalli, Chesnel Dey; Norgaard, Bjarne Linde; Leipsic, Jonathon

    2016-01-01

    This study aims to determine the potential impact of introducing noninvasive fractional flow reserve based on coronary computed tomography angiography (CTA) into clinical practice, with respect to radiation dose exposure and downstream event rate. We modeled a population of 1000 stable, symptomatic patients with suspected coronary artery disease, using the disease prevalence from the CONFIRM registry to estimate the pretest likelihood. Four potential clinical pathways were modeled based on the first noninvasive diagnostic test performed: (1) dobutamine echo; (2) single-photon emission computerized tomography (SPECT); (3) coronary CTA; and (4) CTA+FFRCT and leading to possible invasive coronary angiography. The posttest likelihood of testing positive/negative by each test was based on the presenting disease burden and diagnostic accuracy of each test. The dobutamine echo pathway resulted in the lowest radiation dose of 5.4 mSv, with 4.0 mSv from angiography and 1.4 mSv from percutaneous coronary intervention (PCI). The highest dose was with SPECT, with 26.5 mSv. The coronary computed tomography angiography (cCTA) pathway demonstrated a dose of 14.2 mSv, 3.7 mSv from cCTA, 7.7 mSv from angiography, and 2.8 mSv from PCI. The CTA+FFRCT pathway exhibited a radiation dose of 9.7 mSv, 3.7 mSv for cCTA, 4.2 mSv for angiography, and 1.8 mSv for PCI. Radiation dose exposure for CTA+FFRCT was lower than for SPECT (P<.001). The CTA+FFRCT pathway resulted in the lowest projected death/myocardial infarction rate at 1 year (2.44%) while the dobutamine stress pathway had the highest 1-year event rate (2.84%). Our analysis suggests that integrating FFRCT into the CTA clinical pathway may result in reduced cumulative radiation exposure, while promoting favorable clinical outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Clinical and radiologic manifestations of congenital extrahepatic portosystemic shunts: a comprehensive review.

    PubMed

    Alonso-Gamarra, Eduardo; Parrón, Manuel; Pérez, Ana; Prieto, Consuelo; Hierro, Loreto; López-Santamaría, Manuel

    2011-01-01

    Congenital extrahepatic portosystemic shunt (CEPS) is a rare condition in which the portomesenteric blood drains into a systemic vein, bypassing the liver through a complete or partial shunt. Most often, the diagnosis is made primarily with Doppler ultrasonography. Computed tomographic angiography and magnetic resonance angiography are used for further classification of the shunt and assessment of accompanying anomalies. Conventional angiography is necessary when results of the other tests disagree or are inconclusive. CEPS is classified into two types according to the pattern of anastomoses between the portal vein and systemic vein. In type 1, intrahepatic portal venous supply is absent; in type 2, intrahepatic portal venous supply is preserved. Type 1 usually occurs in girls with associated malformations, such as situs ambiguous with polysplenia and congenital heart defects. Associated anomalies are less frequent in type 2, and symptoms usually develop later without a gender preference. Hepatic encephalopathy and liver dysfunction are possible complications of both types and usually develop during adulthood. Both types are also associated with regenerative hepatic nodules. The clinical setting and imaging appearance of these nodules can help one avoid misdiagnosis. Definitive treatment of CEPS is determined by the type of shunt. Liver transplantation is the only effective treatment for symptomatic type 1 CEPS; surgical closure or embolization of the shunt is the therapeutic approach for type 2. Copyright © RSNA, 2011.

  2. Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

    PubMed

    Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui

    2014-01-01

    The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.

  3. Bilateral medial medullary infarction due to bilateral vertebral artery dissection.

    PubMed

    Fukuda, Masafumi; Aiba, Toyotaka; Takahashi, Sho

    2004-03-01

    We describe a 52-year-old woman who experienced transient motor weakness and numbness of the left extremities and presented 2 days later with severe hemiparesis and sensory impairment of the right extremities and right lingual palsy. Magnetic resonance imaging (MRI) revealed bilateral upper medial medullary infarction, primarily in the left ventral portion. The findings of both three-dimensional (3D) computed tomographic and conventional angiography suggested dissection of both intracranial vertebral arteries (VAs). Medial medullary infarction is generally caused by atherosclerosis within a VA or anterior spinal artery. This is the first report of bilateral medial medullary infarction due to dissection of both intracranial VAs.

  4. Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan.

    PubMed Central

    van Rossum, A. B.; Treurniet, F. E.; Kieft, G. J.; Smith, S. J.; Schepers-Bok, R.

    1996-01-01

    BACKGROUND: A study was carried out to evaluate the potential place of spiral volumetric computed tomography (SVCT) in the diagnostic strategy for pulmonary embolism. METHODS: In a prospective study 249 patients with clinical suspicion of pulmonary embolism were evaluated with various imaging techniques. In all patients a ventilation/perfusion (V/Q) scan was performed. Seventy seven patients with an abnormal V/Q scan underwent SVCT. Pulmonary angiography was then performed in all 42 patients with a non-diagnostic V/Q scan and in three patients with a high probability V/Q scan without emboli on the SVCT scan. Patients with an abnormal perfusion scan also underwent ultrasonography of the legs for the detection of deep vein thrombosis. RESULTS: One hundred and seventy two patients (69%) had a normal V/Q scan. Forty two patients (17%) had a non-diagnostic V/Q scan, and in five of these patients pulmonary emboli were found both by SVCT and pulmonary angiography. In one patient, although SVCT showed no emboli, the angiogram was positive for pulmonary embolism. In one of the 42 patients the SVCT scan showed an embolus which was not confirmed by pulmonary angiography. The other 35 patients showed no sign of emboli. Thirty five patients (14%) had a high probability V/Q scan, and in 32 patients emboli were seen on SVCT images. Two patients had both a negative SVCT scan and a negative pulmonary angiogram. In one who had an inconclusive SVCT scan pulmonary angiography was positive. The sensitivity for pulmonary embolism was 95% and the specificity 97%; the positive and negative predicted values of SVCT were 97% and 97%, respectively. CONCLUSIONS: SVCT is a relatively noninvasive test for pulmonary embolism which is both sensitive and specific and which may serve as an alternative to ventilation scintigraphy and possibly to pulmonary angiography in the diagnostic strategy for pulmonary embolism. Images PMID:8658363

  5. [Preoperative CT angiography for planning free perforator flaps in breast reconstruction].

    PubMed

    Kuekrek, H; Müller, D; Paepke, S; Dobritz, M; Machens, H-G; Giunta, R E

    2011-04-01

    Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used Doppler ultrasonography there are disadvantages like the additional cost factor and the radiation exposure. However, in our experience the more detailed planning increases the safety of flap raising and reduces surgery time, so that we consider CT angiography a positive tool to facilitate free perforator flaps. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Differentiation of early from advanced coronary atherosclerotic lesions: systematic comparison of CT, intravascular US, and optical frequency domain imaging with histopathologic examination in ex vivo human hearts.

    PubMed

    Maurovich-Horvat, Pál; Schlett, Christopher L; Alkadhi, Hatem; Nakano, Masataka; Stolzmann, Paul; Vorpahl, Marc; Scheffel, Hans; Tanaka, Atsushi; Warger, William C; Maehara, Akiko; Ma, Shixin; Kriegel, Matthias F; Kaple, Ryan K; Seifarth, Harald; Bamberg, Fabian; Mintz, Gary S; Tearney, Guillermo J; Virmani, Renu; Hoffmann, Udo

    2012-11-01

    To establish an ex vivo experimental setup for imaging coronary atherosclerosis with coronary computed tomographic (CT) angiography, intravascular ultrasonography (US), and optical frequency domain imaging (OFDI) and to investigate their ability to help differentiate early from advanced coronary plaques. All procedures were performed in accordance with local and federal regulations and the Declaration of Helsinki. Approval of the local Ethics Committee was obtained. Overall, 379 histologic cuts from nine coronary arteries from three donor hearts were acquired, coregistered among modalities, and assessed for the presence and composition of atherosclerotic plaque. To assess the discriminatory capacity of the different modalities in the detection of advanced lesions, c statistic analysis was used. Interobserver agreement was assessed with the Cohen κ statistic. Cross sections without plaque at coronary CT angiography and with fibrous plaque at OFDI almost never showed advanced lesions at histopathologic examination (odds ratio [OR]: 0.02 and 0.06, respectively; both P<.0001), while mixed plaque at coronary CT angiography, calcified plaque at intravascular US, and lipid-rich plaque at OFDI were associated with advanced lesions (OR: 2.49, P=.0003; OR: 2.60, P=.002; and OR: 31.2, P<.0001, respectively). OFDI had higher accuracy for discriminating early from advanced lesions than intravascular US and coronary CT angiography (area under the receiver operating characteristic curve: 0.858 [95% confidence interval {CI}: 0.802, 0.913], 0.631 [95% CI: 0.554, 0.709], and 0.679 [95% CI: 0.618, 0.740]; respectively, P<.0001). Interobserver agreement was excellent for OFDI and coronary CT angiography (κ=0.87 and 0.85, respectively) and was good for intravascular US (κ=0.66). Systematic and standardized comparison between invasive and noninvasive modalities for coronary plaque characterization in ex vivo specimens demonstrated that coronary CT angiography and intravascular US are reasonably associated with plaque composition and lesion grading according to histopathologic findings, while OFDI was strongly associated. These data may help to develop initial concepts of sequential imaging strategies to identify patients with advanced coronary plaques. © RSNA, 2012

  7. Can Radiation Dose Be Reduced and Image Quality Improved With 80-kV and Dual-Phase Scanning of the Lower Extremities With 64-Slice Computed Tomography Angiography?

    PubMed

    Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan

    2015-01-01

    To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.

  8. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juszkat, Robert, E-mail: radiologiamim@wp.p; Pukacki, Fryderyk; Zarzecka, Anna

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The proceduremore » was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.« less

  9. Aneurysm of the intradural artery of Adamkiewicz treated with muslin wrapping: technical case report.

    PubMed

    Vishteh, A G; Brown, A P; Spetzler, R F

    1997-01-01

    An exceedingly rare, isolated spinal arterial aneurysm and its management are presented. A 30-year-old man who presented with severe lower back pain and headache underwent a computed tomographic study of his head that disclosed nothing abnormal and a lumbar puncture that revealed bloody, xanthochromic cerebrospinal fluid. The findings from cerebral angiography were normal, and the results from spinal angiography were consistent with a diagnosis of an aneurysm of the artery of Adamkiewicz. A transthoracic approach with a partial T11 vertebrectomy gained exposure to this anteriorly located lesion. A fusiform aneurysm of the intradural portion of the artery of Adamkiewicz was discovered. Excision of the aneurysm with a vascular bypass was deemed impossible. The lesion was treated with muslin wrapping. One year after surgery, the patient remains at his baseline neurological condition. A review of the literature revealed only one other reported case of a ruptured aneurysm of the artery of Adamkiewicz, which was discovered postmortem. Therefore, this case represents the first report of a diagnosed and treated artery of Adamkiewicz aneurysm.

  10. Coronary angiography in Qatar: the first ten years.

    PubMed

    Chaikhouni, A; Gehani, A A; Horak, J; Hajar, H A

    1998-08-01

    Cardiac catheterization in Qatar was initiated in July 1982. In ten years, a total of 3900 procedures were performed at Hamad General Hospital. Computerized data registry has been maintained since 1982. Isolated coronary angiography was done in 2911 patients; of these, 2635 (90.5%) were men, and 276 (9.5%) were women, the average age of the patients was 47+/-9.2 years (range, twenty-five to eighty-eight). Patients' nationality was Qatari in 492 (17%), and other Arabs in 610 (21%), and 1512 (52%) were from the Asian subcontinent. Myocardial infarction was the most common indication (43%). Single-vessel disease was found in 638 (22%), two-vessel disease in 630 (22%), three-vessel disease in 950 (33%), and nonsignificant coronary artery disease in 693 (24%) patients. Morbidity related to the coronary angiography was reported in 147 (5%) patients, but there was no mortality related to the procedure. In 822 (28%) patients, the age was forty years or younger. The angiographic findings of these younger patients were compared with those of the older ones. Younger patients were usually men of Asian subcontinental origin with a recent myocardial infarction (MI). Often, they had normal coronary arteries or single-vessel disease. Patients of Asian subcontinent origin were usually young male patients with a recent MI, who receive streptokinase, and have single-vessel disease.

  11. Telestroke Imaging: A Review.

    PubMed

    Laghari, Fahad J; Hammer, Maxim D

    2017-01-01

    The use of telecommunications technology to provide the healthcare services, telemedicine, has been in use since the 1860s. The use of technology has ranged from providing medical care to far-off places during wartimes to monitoring physiological measurements of astronauts in space. Since the 1990s, reports have been published on diagnoses of neurological diseases with the use of video links. Studies confirm that the neurological examinations, including the National Institutes of Health Stroke Scale, performed during teleneurology are dependable. The transfer of stroke patients in rural hospitals to bigger medical centers delays treatment while there exists current and projected shortage of neurologists. Telestroke provides the solution. Patients suspected of acute stroke need a noncontrast computerized tomography (CT) scan for tissue plasminogen activator administration. Vascular imaging such as CT angiography, magnetic resonance angiography, and digital subtraction angiography can help show large-vessel occlusion or critical stenosis responsive to endovascular therapy. A standard protocol can be followed to decide a vascular modality of choice, considering advantages and disadvantages of each imaging modality. Telestroke solves the problems of distance and of shortage of neurologists. Neuroimaging plays a vital role in the delivery of telestroke, and the telestroke doctor should be comfortable with making a decision on selecting an appropriate vascular imaging modality. Copyright © 2016 by the American Society of Neuroimaging.

  12. Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

    PubMed

    Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan

    2009-04-01

    Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.

  13. Navigation with Electromagnetic Tracking for Interventional Radiology Procedures

    PubMed Central

    Wood, Bradford J.; Zhang, Hui; Durrani, Amir; Glossop, Neil; Ranjan, Sohan; Lindisch, David; Levy, Eliott; Banovac, Filip; Borgert, Joern; Krueger, Sascha; Kruecker, Jochen; Viswanathan, Anand; Cleary, Kevin

    2008-01-01

    PURPOSE To assess the feasibility of the use of preprocedural imaging for guide wire, catheter, and needle navigation with electromagnetic tracking in phantom and animal models. MATERIALS AND METHODS An image-guided intervention software system was developed based on open-source software components. Catheters, needles, and guide wires were constructed with small position and orientation sensors in the tips. A tetrahedral-shaped weak electromagnetic field generator was placed in proximity to an abdominal vascular phantom or three pigs on the angiography table. Preprocedural computed tomographic (CT) images of the phantom or pig were loaded into custom-developed tracking, registration, navigation, and rendering software. Devices were manipulated within the phantom or pig with guidance from the previously acquired CT scan and simultaneous real-time angiography. Navigation within positron emission tomography (PET) and magnetic resonance (MR) volumetric datasets was also performed. External and endovascular fiducials were used for registration in the phantom, and registration error and tracking error were estimated. RESULTS The CT scan position of the devices within phantoms and pigs was accurately determined during angiography and biopsy procedures, with manageable error for some applications. Preprocedural CT depicted the anatomy in the region of the devices with real-time position updating and minimal registration error and tracking error (<5 mm). PET can also be used with this system to guide percutaneous biopsies to the most metabolically active region of a tumor. CONCLUSIONS Previously acquired CT, MR, or PET data can be accurately codisplayed during procedures with reconstructed imaging based on the position and orientation of catheters, guide wires, or needles. Multimodality interventions are feasible by allowing the real-time updated display of previously acquired functional or morphologic imaging during angiography, biopsy, and ablation. PMID:15802449

  14. Cost-effectiveness of angiographic imaging in isolated perimesencephalic subarachnoid hemorrhage.

    PubMed

    Kalra, Vivek B; Wu, Xiao; Forman, Howard P; Malhotra, Ajay

    2014-12-01

    The purpose of this study is to perform a comprehensive cost-effectiveness analysis of all possible permutations of computed tomographic angiography (CTA) and digital subtraction angiography imaging strategies for both initial diagnosis and follow-up imaging in patients with perimesencephalic subarachnoid hemorrhage on noncontrast CT. Each possible imaging strategy was evaluated in a decision tree created with TreeAge Pro Suite 2014, with parameters derived from a meta-analysis of 40 studies and literature values. Base case and sensitivity analyses were performed to assess the cost-effectiveness of each strategy. A Monte Carlo simulation was conducted with distributional variables to evaluate the robustness of the optimal strategy. The base case scenario showed performing initial CTA with no follow-up angiographic studies in patients with perimesencephalic subarachnoid hemorrhage to be the most cost-effective strategy ($5422/quality adjusted life year). Using a willingness-to-pay threshold of $50 000/quality adjusted life year, the most cost-effective strategy based on net monetary benefit is CTA with no follow-up when the sensitivity of initial CTA is >97.9%, and CTA with CTA follow-up otherwise. The Monte Carlo simulation reported CTA with no follow-up to be the optimal strategy at willingness-to-pay of $50 000 in 99.99% of the iterations. Digital subtraction angiography, whether at initial diagnosis or as part of follow-up imaging, is never the optimal strategy in our model. CTA without follow-up imaging is the optimal strategy for evaluation of patients with perimesencephalic subarachnoid hemorrhage when modern CT scanners and a strict definition of perimesencephalic subarachnoid hemorrhage are used. Digital subtraction angiography and follow-up imaging are not optimal as they carry complications and associated costs. © 2014 American Heart Association, Inc.

  15. Detection of common carotid artery stenosis using duplex ultrasonography: a validation study with computed tomographic angiography.

    PubMed

    Slovut, David P; Romero, Javier M; Hannon, Kathleen M; Dick, James; Jaff, Michael R

    2010-01-01

    Severe stenosis of the common carotid artery (CCA), while uncommon, is associated with increased risk of transient ischemic attack and stroke. To date, no validated duplex ultrasound criteria have been established for grading the severity of CCA stenosis. The goal of this study was to use receiver-operating curve (ROC) analysis with computed tomographic angiography as the reference standard to establish duplex ultrasound criteria for diagnosing >or=50% CCA stenosis. The study cohort included 64 patients (42 men, 22 women) with a mean age of 65 +/- 12 years (range, 16-89 years) who had CCA peak systolic velocity (PSV) >or=150 cm/sec and underwent computed tomographic angiography (CTA) of the cervical and intracerebral vessels within 1 month of the duplex examination. One study was excluded because the CTA was technically inadequate, whereas another was excluded because the patient underwent bilateral CCA stenting. The CCA ipsilateral to any of the following was excluded from the analysis: innominate artery occlusion (n = 1), previous stenting of the ICA or CCA (n = 7), carotid endarterectomy (n = 1), or carotid-to-carotid bypass (n = 1). Thus, the data set included 62 patients and 115 vessels. Bland-Altman analysis was used to examine the agreement between two measures of luminal reduction measured by CTA: percent diameter stenosis and percent area stenosis. Receiver operating characteristic (ROC) analysis was used to determine optimal PSV and EDV thresholds for diagnosing >or=50% CCA stenosis. Severity of CCA stenosis was <50% in 76 vessels, 50%-59% in eight, 60%-69% in eight, 70%-79% in nine, 80%-89% in three, 90%-99% in five, and occluded in six. Duplex ultrasonography identified six of six (100%) patients with 100% CCA occlusion by CTA. Bland-Altman analysis showed poor agreement between percent stenosis determined by vessel diameter compared with percent stenosis determined by reduction in lumen area. Therefore, subsequent analysis was performed using percent stenosis by area. ROC analysis of different PSV thresholds for detecting stenosis >or=50% showed that >182 cm/sec was the most accurate with a sensitivity of 64% and specificity of 88% (P < .0001). Sensitivity, specificity, and accuracy of carotid duplex were higher when the stenosis was located in the mid or distal aspects of the CCA (sensitivity 76%, specificity 89%, area under curve 0.84, P < .001) than in the intrathoracic and proximal segment of the artery (P = NS). ROC analysis of different EDV thresholds for detecting CCA stenosis >or=50% showed that >30 cm/sec was the most accurate with a sensitivity of 54% and a specificity of 74% (P < .0239). Duplex ultrasonography is highly sensitive, specific, and accurate for detecting CCA lesions in the mid and distal CCA. Use of peak systolic velocity may lead to improved detection of CCA disease and initiation of appropriate therapy to reduce the risk of stroke. Copyright 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  16. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    PubMed

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, <50 HU) volume, and remodelling index. Plaques were qualitatively assessed for CTA features of disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P < 0.0001). Clinically stable patients commonly manifest plaques with features of disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  17. Nasal Chondromesenchymal Hamartoma in a Child

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finitsis, Stefanos; Giavroglou, Constantinos; Potsi, Stamatia, E-mail: matinapotsi@hotmail.co

    Nasal chondromesenchymal hamartoma (NCMH) is a benign tumor that was described in 1998. The occurrence of this lesion in the nasal cavity of infants and children is especially rare, with only 21 cases reported in the international literature. We report a 12-month-old boy with respiratory distress due to nasal obstruction. Computed tomographic scan and magnetic resonance imaging examination demonstrated a soft-tissue mass obstructing the left nasal cavity. Digital subtraction angiography and preoperative superselective embolization with microparticles were also performed. The tumor was completely resected surgically. Histopathology and immunohistochemical analyses of the tumor disclosed a NCMH. The imaging characteristics of themore » tumor are described and the radiology literature is reviewed.« less

  18. Solitary kidney with renal artery aneurysm repaired by ex vivo reconstruction.

    PubMed

    Palcau, Laura; Gouicem, Djelloul; Joguet, Etienne; Cameliere, Lucie; Berger, Ludovic

    2014-01-01

    A 22-year-old pregnant female with pyelonephritis was found to have a 26-mm left renal artery aneurysm with unknown right kidney agenesis diagnosed by magnetic resonance imaging. Computed tomographic angiography with 3-dimensional reconstructions confirmed a saccular aneurysm localized at the bifurcation of the left posterior segmental artery. The patient ultimately underwent successful ex vivo left renal artery aneurysm repair with autotransplantation. Pathologic evaluation of the resected aneurysm confirmed the diagnosis of fibromuscular dysplasia. Fibromuscular dysplasia is the most common cause of renal artery stenosis and renovascular hypertension and can, in rare cases, be associated with the development of renal artery aneurysms. © The Author(s) 2014.

  19. [Imaging of temporo-mandibular disorders].

    PubMed

    Felizardo, Rufino; Foucart, Jean-Michel; Pizelle, Christophe

    2012-03-01

    Dominated for years by standard films (tomographic mouth open and mouth closed X-rays, MRI) radiographs of the TMJ have progressively lost their usefulness to diagnosticians who have progressively increased their reliance on well codified clinical examinations, which suffice in a great majority of cases.The indications for and diagnostic worth of radiological studies and the impact they have on the management of TMJ disorders are today quite low especially when the high cost of procedures like MRI, computerized tomography, and CBCT is taken into account. In this article we discuss the various maladies that dentists might encounter and the situations in which radiological examinations are still indicated. © EDP Sciences, SFODF, 2012.

  20. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy

    2009-05-15

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic andmore » computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.« less

  1. Intrahepatic Flow Redistribution in Patients Treated with Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spreafico, Carlo, E-mail: carlo.spreafico@istitutotumori.mi.it; Morosi, Carlo, E-mail: carlo.morosi@istitutotumori.mi.it; Maccauro, Marco, E-mail: marco.maccauro@istitutotumori.mi.it

    2015-04-15

    IntroductionIn planning Yttrium-90 ({sup 90}Y)-radioembolizations, strategy problems arise in tumours with multiple arterial supplies. We aim to demonstrate that tumours can be treated via one main feeding artery achieving flow redistribution by embolizing accessory vessels.MethodsOne hundred {sup 90}Y-radioembolizations were performed on 90 patients using glass microspheres. In 19 lesions/17 patients, accessory branches were found feeding a minor tumour portion and embolized. In all 17 patients, the assessment of the complete perfusion was obtained by angiography and single photon emission computerized tomography–computerized tomography (SPECT–CT). Dosimetry, toxicity, and tumor response rate of the patients treated after flow redistribution were compared with themore » 83 standard-treated patients. Seventeen lesions in 15 patients with flow redistribution were chosen as target lesions and evaluated according to mRECIST criteria.ResultsIn all patients, the complete tumor perfusion was assessed immediately before radioembolization by angiography in all patients and after the {sup 90}Y-infusion by SPECT–CT in 15 of 17 patients. In the 15 assessable patients, the response rate in their 17 lesions was 3 CR, 8 PR, and 6 SD. Dosimetric and toxicity data, as well tumour response rate, were comparable with the 83 patients with regular vasculature.ConclusionsAll embolization procedures were performed successfully with no complications, and the flow redistribution was obtained in all cases. Results in term of toxicity, median dose administered, and radiological response were comparable with standard radioembolizations. Our findings confirmed the intratumoral flow redistribution after embolizing the accessory arteries, which makes it possible to treat the tumour through its single main feeding artery.« less

  2. Clinical anatomy of the orbitomeningeal foramina: variational anatomy of the canals connecting the orbit with the cranial cavity.

    PubMed

    Macchi, Veronica; Regoli, Marì; Bracco, Sandra; Nicoletti, Claudio; Morra, Aldo; Porzionato, Andrea; De Caro, Raffaele; Bertelli, Eugenio

    2016-03-01

    In addition to the optic canal and the superior orbital fissure, orbits are connected with the cranial cavity via inconstant canals including the orbitomeningeal foramen. This study has been carried out in order to define many anatomical and radiological details of the orbitomeningeal foramen that are relevant in the clinical practice. Almost 1000 skulls and 50 computerized tomographies were examined to determine incidence, number, length, and caliber of the orbitomeningeal foramen as well as the topography of their orbital and cranial openings. A retrospective study of angiographies carried out on more than 100 children was performed to look for arteries candidate to run through the orbitomeningeal foramen. Orbitomeningeal foramina were detected in 59.46% of skulls and in 54% of individuals by computerized tomography. Orbits with two to five foramina were found. Canals were classified as M-subtype or A-subtype depending on their cranial opening. Large foramina, with the caliber ranging between 1 and 3 mm, were found in 12.17% of orbitomeningeal foramen-bearing orbits. By computed tomography the average caliber measured 1.2 ± 0.3 and 1.5 ± 0.5 mm (p < 0.005) at the orbital and cranial openings, respectively (p < 0.005). Angiographies showed meningo-lacrimal and meningo-ophthalmic arteries, meningeal branches of the lacrimal and supraorbital arteries, and some unidentified arteries that could pass through the orbitomeningeal foramina. Orbitomeningeal foramina are a common occurrence. When large they may house important arteries that can be the source of severe bleedings during deep dissection of the lateral wall of the orbit. Orbital surgeons should be aware of their existence.

  3. Fractional flow reserve by computerized tomography and subsequent coronary revascularization

    PubMed Central

    Packard, René R. Sevag; Li, Dong; Budoff, Matthew J.; Karlsberg, Ronald P.

    2017-01-01

    Aims Fractional flow reserve by computerized tomography (FFR-CT) provides non-invasive functional assessment of the hemodynamic significance of coronary artery stenosis. We determined the FFR-CT values, receiver operator characteristic (ROC) curves, and predictive ability of FFR-CT for actual standard of care guided coronary revascularization. Methods and results Consecutive outpatients who underwent coronary CT angiography (coronary CTA) followed by invasive angiography over a 24-month period from 2012 to 2014 were identified. Studies that fit inclusion criteria (n = 75 patients, mean age 66, 75% males) were sent for FFR-CT analysis, and results stratified by coronary artery calcium (CAC) scores. Coronary CTA studies were re-interpreted in a blinded manner, and baseline FFR-CT values were obtained retrospectively. Therefore, results did not interfere with clinical decision-making. Median FFR-CT values were 0.70 in revascularized (n = 69) and 0.86 in not revascularized (n = 138) coronary arteries (P < 0.001). Using clinically established significance cut-offs of FFR-CT ≤0.80 and coronary CTA ≥70% stenosis for the prediction of clinical decision-making and subsequent coronary revascularization, the positive predictive values were 74 and 88% and negative predictive values were 96 and 84%, respectively. The area under the curve (AUC) for all studied territories was 0.904 for coronary CTA, 0.920 for FFR-CT, and 0.941 for coronary CTA combined with FFR-CT (P = 0.001). With increasing CAC scores, the AUC decreased for coronary CTA but remained higher for FFR-CT (P < 0.05). Conclusion The addition of FFR-CT provides a complementary role to coronary CTA and increases the ability of a CT-based approach to identify subsequent standard of care guided coronary revascularization. PMID:27469588

  4. Recanalization and clinical outcome of occlusion sites at baseline CT angiography in the Interventional Management of Stroke III trial.

    PubMed

    Demchuk, Andrew M; Goyal, Mayank; Yeatts, Sharon D; Carrozzella, Janice; Foster, Lydia D; Qazi, Emmad; Hill, Michael D; Jovin, Tudor G; Ribo, Marc; Yan, Bernard; Zaidat, Osama O; Frei, Donald; von Kummer, Rüdiger; Cockroft, Kevin M; Khatri, Pooja; Liebeskind, David S; Tomsick, Thomas A; Palesch, Yuko Y; Broderick, Joseph P

    2014-10-01

    To use baseline computed tomographic (CT) angiography to analyze imaging and clinical end points in an Interventional Management of Stroke III cohort to identify patients who would benefit from endovascular stroke therapy. The primary clinical end point was 90-day dichotomized modified Rankin Scale (mRS) score. Secondary end points were 90-day mRS score distribution and 24-hour recanalization. Prespecified subgroup was baseline proximal occlusions (internal carotid, M1, or basilar arteries). Exploratory analyses were subsets with any occlusion and specific sites of occlusion (two-sided α = .01). Of 656 subjects, 306 (47%) underwent baseline CT angiography or magnetic resonance angiography. Of 306, 282 (92%) had arterial occlusions. At baseline CT angiography, proximal occlusions (n = 220) demonstrated no difference in primary outcome (41.3% [62 of 150] endovascular vs 38% [27 of 70] intravenous [IV] tissue-plasminogen activator [tPA]; relative risk, 1.07 [99% confidence interval: 0.67, 1.70]; P = .70); however, 24-hour recanalization rate was higher for endovascular treatment (n = 167; 84.3% [97 of 115] endovascular vs 56% [29 of 52] IV tPA; P < .001). Exploratory subgroup analysis for any occlusion at baseline CT angiography did not demonstrate significant differences between endovascular and IV tPA arms for primary outcome (44.7% [85 of 190] vs 38% [35 of 92], P = .29), although ordinal shift analysis of full mRS distribution demonstrated a trend toward more favorable outcome (P = .011). Carotid T- or L-type occlusion (terminal internal carotid artery [ICA] with M1 middle cerebral artery and/or A1 anterior cerebral artery involvement) or tandem (extracranial or intracranial) ICA and M1 occlusion subgroup also showed a trend favoring endovascular treatment over IV tPA alone for primary outcome (26% [12 of 46] vs 4% [one of 23], P = .047). Significant differences were identified between treatment arms for 24-hour recanalization in proximal occlusions; carotid T- or L-type and tandem ICA and M1 occlusions showed greater recanalization and a trend toward better outcome with endovascular treatment. Vascular imaging should be mandated in future endovascular trials to identify such occlusions. Online supplemental material is available for this article. © RSNA, 2014.

  5. Diagnostic value of QRS and S wave variation in patients with suspicion of acute pulmonary embolism.

    PubMed

    Çağdaş, Metin; Karakoyun, Süleyman; Rencüzoğulları, İbrahim; Karabağ, Yavuz; Artaç, İnanç; İliş, Doğan; Hamideyin, Şerif; Karayol, Sibel; Çiftçi, Handan; Çınar, Tufan

    2018-03-29

    This study aimed to investigate the diagnostic value of QRS and S wave variation in patients admitted to the emergency department with suspicion of acute pulmonary embolism (APE). Computerized tomographic pulmonary angiography (CTPA) was performed in 118 consecutive patients to evaluate patients with suspected APE, and 106 subjects with appropriate electrocardiogram and CT images constituted the study population. Using CTPA, APE was diagnosed in 48.1% (n:51) of the study population. The comparison of patients with APE and those without APE revealed that increased heart rate, right axis deviation of QRS axis, complete or incomplete right bundle branch block, prominent S wave in lead D1, increased QRS duration, percentage of QRS (9,8[4,8-19,0] vs 3,8[2,7-71]; p<0,001), S wave variation (22,3[9,6-31,9] vs 4,8 [2-8]; p<0,001) and ΔS wave amplitude (1.1[0.5-1.5] vs 0.2[0.1-0.5]; p<0.001) were significantly associated with APE, but no relationship was detected with respect to the presence of atrial arrhythmias, clockwise rotation of the horizontal axis, fragmentation, ST segment deviation, T wave inversion, and S1Q3T3 and S1S2S3 patterns. The percentage of S wave variation (OR: 1072 per 1% increase, 95% CI:1011-1137) was found to be an independent predictor of APE. ΔS wave amplitude>0.5mm predicted APE with a sensitivity of 72.6% and a specificity of 74.6% (AUC:0.805, 95% CI: 0.717-0.876; p<0.001). The present study demonstrated that QRS and S wave variation could be useful electrocardiographic signs for the diagnosis of APE. Copyright © 2018. Published by Elsevier Inc.

  6. Predicting Intracerebral Hemorrhage Expansion With Noncontrast Computed Tomography: The BAT Score.

    PubMed

    Morotti, Andrea; Dowlatshahi, Dar; Boulouis, Gregoire; Al-Ajlan, Fahad; Demchuk, Andrew M; Aviv, Richard I; Yu, Liyang; Schwab, Kristin; Romero, Javier M; Gurol, M Edip; Viswanathan, Anand; Anderson, Christopher D; Chang, Yuchiao; Greenberg, Steven M; Qureshi, Adnan I; Rosand, Jonathan; Goldstein, Joshua N

    2018-05-01

    Although the computed tomographic angiography spot sign performs well as a biomarker for hematoma expansion (HE), computed tomographic angiography is not routinely performed in the emergency setting. We developed and validated a score to predict HE-based on noncontrast computed tomography (NCCT) findings in spontaneous acute intracerebral hemorrhage. After developing the score in a single-center cohort of patients with intracerebral hemorrhage (n=344), we validated it in a large clinical trial population (n=954) and in a multicenter intracerebral hemorrhage cohort (n=241). The following NCCT markers of HE were analyzed: hypodensities, blend sign, hematoma shape and density, and fluid level. HE was defined as hematoma growth >6 mL or >33%. The score was created using the estimates from multivariable logistic regression after final predictors were selected from bootstrap samples. Presence of blend sign (odds ratio, 3.09; 95% confidence interval [CI],1.49-6.40; P =0.002), any intrahematoma hypodensity (odds ratio, 4.54; 95% CI, 2.44-8.43; P <0.0001), and time from onset to NCCT <2.5 hours (odds ratio, 3.73; 95% CI, 1.86-7.51; P =0.0002) were predictors of HE. A 5-point score was created (BAT score: 1 point for blend sign, 2 points for any hypodensity, and 2 points for timing of NCCT <2.5 hours). The c statistic was 0.77 (95% CI, 0.70-0.83) in the development population, 0.65 (95% CI 0.61-0.68) and 0.70 (95% CI, 0.64-0.77) in the 2 validation cohorts. A dichotomized score (BAT score ≥3) predicted HE with 0.50 sensitivity and 0.89 specificity. An easy to use 5-point prediction score can identify subjects at high risk of HE with good specificity and accuracy. This tool requires just a baseline NCCT scan and may help select patients with intracerebral hemorrhage for antiexpansion clinical trials. © 2018 American Heart Association, Inc.

  7. Rate of Contrast Extravasation on Computed Tomographic Angiography Predicts Hematoma Expansion and Mortality in Primary Intracerebral Hemorrhage.

    PubMed

    Brouwers, H Bart; Battey, Thomas W K; Musial, Hayley H; Ciura, Viesha A; Falcone, Guido J; Ayres, Alison M; Vashkevich, Anastasia; Schwab, Kristin; Viswanathan, Anand; Anderson, Christopher D; Greenberg, Steven M; Pomerantz, Stuart R; Ortiz, Claudia J; Goldstein, Joshua N; Gonzalez, R Gilberto; Rosand, Jonathan; Romero, Javier M

    2015-09-01

    In primary intracerebral hemorrhage, the presence of contrast extravasation after computed tomographic angiography (CTA), termed the spot sign, predicts hematoma expansion and mortality. Because the biological underpinnings of the spot sign are not fully understood, we investigated whether the rate of contrast extravasation, which may reflect the rate of bleeding, predicts expansion and mortality beyond the simple presence of the spot sign. Consecutive intracerebral hemorrhage patients with first-pass CTA followed by a 90-second delayed postcontrast CT (delayed CTA) were included. CTAs were reviewed for spot sign presence by 2 blinded readers. Spot sign volumes on first-pass and delayed CTA and intracerebral hemorrhage volumes were measured using semiautomated software. Extravasation rates were calculated and tested for association with hematoma expansion and mortality using uni- and multivariable logistic regressions. One hundred and sixty-two patients were included, 48 (30%) of whom had ≥1 spot sign. Median spot sign volume was 0.04 mL on first-pass CTA and 0.4 mL on delayed CTA. Median extravasation rate was 0.23 mL/min overall and 0.30 mL/min among expanders versus 0.07 mL/min in nonexpanders. Extravasation rates were also significantly higher in patients who died in hospital: 0.27 mL/min versus 0.04 mL/min. In multivariable analysis, the extravasation rate was independently associated with in-hospital mortality (odds ratio, 1.09 [95% confidence interval, 1.04-1.18], P=0.004), 90-day mortality (odds ratio, 1.15 [95% confidence interval, 1.08-1.27]; P=0.0004), and hematoma expansion (odds ratio, 1.03 [95% confidence interval, 1.01-1.08]; P=0.047). Contrast extravasation rate, or spot sign growth, further refines the ability to predict hematoma expansion and mortality. Our results support the hypothesis that the spot sign directly measures active bleeding in acute intracerebral hemorrhage. © 2015 American Heart Association, Inc.

  8. Influence of arterial occlusion on outcome after intravenous thrombolysis for acute ischemic stroke.

    PubMed

    Medlin, Friedrich; Amiguet, Michael; Vanacker, Peter; Michel, Patrik

    2015-01-01

    We aimed to assess the interaction between intravenous thrombolysis (IVT) and arterial occlusion on acute cervicocerebral computed tomographic angiography on the outcome of patients with acute ischemic stroke. Patients from the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) registry with onset-to-door-time ≤4 hours, acute cervicocerebral computed tomographic angiography, a premorbid modified Rankin Scale ≤2, and a National Institute of Health Stroke Scale (NIHSS) >4 were selected. Patients with significant intracranial arterial obstruction (≥50%-99%) and undergoing acute endovascular treatment were excluded. An interaction analysis of IVT and initial arterial occlusion for favorable 3 months outcome (modified Rankin Scale <3) were performed with adjustment for potential confounders. Among 654 included patients, 382 (58%) showed arterial occlusion, of whom 263 (69%) received IVT. Two hundred seventy-two showed no/minimal obstruction of whom 139 (51%) received IVT. In the adjusted interaction analysis, there was a trend in favor of the arterial occlusion group (odds ratio [OR]=3.97; 95% confidence interval [CI], 0.83-18.97; P=0.08). IVT (versus no IVT) was associated with better outcome in patients with occlusion (adjusted OR for favorable outcome, 3.01; 95% CI, 1.10-8.28) but not in patients with no/minimal obstruction (OR, 0.76; 95% CI, 0.21-2.74). Conversely, patients with occlusion had a similar rate of favorable outcome as no/minimal obstruction when thrombolysed (OR, 0.5; 95% CI, 0.17-1.47) but had a less favorable outcome without thrombolysis (OR, 0.13; 95% CI, 0.04-0.44). In this retrospective analysis of consecutive patients with acute ischemic stroke, there was a trend for more favorable outcomes with IVT in the setting of initial arterial occlusion than in the setting of no/minimal obstruction. Before confirmation in randomized controlled studies, this information should not influence thrombolysis decisions, however. © 2014 American Heart Association, Inc.

  9. Coronary revascularization vs. medical therapy following coronary-computed tomographic angiography in patients with low-, intermediate- and high-risk coronary artery disease: results from the CONFIRM long-term registry

    PubMed Central

    Schulman-Marcus, Joshua; Lin, Fay Y.; Gransar, Heidi; Berman, Daniel; Callister, Tracy; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Al-Mallah, Mouaz; Budoff, Matthew; Kaufmann, Philipp; Achenbach, Stephan; Raff, Gilbert; Chinnaiyan, Kavitha; Cademartiri, Filippo; Maffei, Erica; Villines, Todd; Kim, Yong-Jin; Leipsic, Jonathon; Feuchtner, Gudrun; Rubinshtein, Ronen; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Chang, Hyuk-Jae; Chow, Benjamin J.W.; Cury, Ricardo C.; Dunning, Allison; Shaw, Leslee; Min, James K.

    2017-01-01

    Abstract Aims To identify the effect of early revascularization on 5-year survival in patients with CAD diagnosed by coronary-computed tomographic angiography (CCTA). Methods and results We examined 5544 stable patients with suspected CAD undergoing CCTA who were followed a median of 5.5 years in a large international registry. Patients were categorized as having low-, intermediate-, or high-risk CAD based on CCTA findings. Two treatment groups were defined: early revascularization within 90 days of CCTA (n = 1171) and medical therapy (n = 4373). To account for the non-randomized referral to revascularization, we developed a propensity score by logistic regression. This score was incorporated into Cox proportional hazard models to calculate the effect of revascularization on all-cause mortality. Death occurred in 363 (6.6%) patients and was more frequent in medical therapy. In multivariable models, when compared with medical therapy, the mortality benefit of revascularization varied significantly over time and by CAD risk (P for interaction 0.04). In high-risk CAD, revascularization was significantly associated with lower mortality at 1 year (hazard ratio [HR] 0.22, 95% confidence interval [CI] 0.11–0.47) and 5 years (HR 0.31, 95% CI 0.18–0.54). For intermediate-risk CAD, revascularization was associated with reduced mortality at 1 year (HR 0.45, 95% CI 0.22–0.93) but not 5 years (HR 0.63, 95% CI 0.33–1.20). For low-risk CAD, there was no survival benefit at either time point. Conclusions Early revascularization was associated with reduced 1-year mortality in intermediate- and high-risk CAD detected by CCTA, but this association only persisted for 5-year mortality in high-risk CAD. PMID:28329294

  10. Multimodal imaging findings in 'hyper-early' stage MEWDS.

    PubMed

    Cahuzac, Armelle; Wolff, Benjamin; Mathis, Thibaud; Errera, Marie-Hélène; Sahel, José-Alain; Mauget-Faÿsse, Martine

    2017-10-01

    To describe a new stage of multiple evanescent white dot syndrome (MEWDS), occurring at a very early phase of the disease. Retrospective analysis of clinical, angiographic and tomographic findings in four patients with 'hyper-early' stage MEWDS. In four patients seen within 1 week of the onset of symptoms, fundus analysis revealed macular granity and the classic yellow-white dots, some having no corresponding hyperautofluorescent pattern. Spectral-domain optical coherence tomography (SD-OCT) showed central foveal disruption of the ellipsoid zone (EZ) and interdigitation layer with a hyper-reflective dome-shaped lesion. In two patients, fluorescein angiography (FA) revealed an intermediate hypofluorescent perimacular halo, whereas late indocyanine green angiography (ICGA) showed a hyperfluorescent halo as well as the classic MEWDS features. After a few days, the EZ disruption appeared complete on OCT and fundus autofluorescence (FAF) in all patients. Visual acuity, OCT and FAF findings had fully recovered within 3 months. We have shown a new feature of MEWDS on FAF, OCT, FA and ICGA, corresponding to a very early stage of the disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Optical Coherence Tomographic Angiography in Type 2 Diabetes and Diabetic Retinopathy.

    PubMed

    Ting, Daniel Shu Wei; Tan, Gavin Siew Wei; Agrawal, Rupesh; Yanagi, Yasuo; Sie, Nicole Ming; Wong, Chee Wai; San Yeo, Ian Yew; Lee, Shu Yen; Cheung, Chui Ming Gemmy; Wong, Tien Yin

    2017-04-01

    Optical coherence tomographic angiography (OCT-A) is able to visualize retinal microvasculature without the need for injection of fluorescein contrast dye. Nevertheless, it is only able to capture a limited view of macula and does not show leakage. To evaluate the retinal microvasculature using OCT-A in patients with type 2 diabetes as well as the association of OCT-A characteristics with diabetic retinopathy (DR) and systemic risk factors. A prospective, observational study was conducted from January 1 to June 30, 2016, at medical retina clinics at the Singapore National Eye Center among 50 patients with type 2 diabetes with and without DR (n = 100 eyes). We examined the retinal microvasculature with swept-source OCT-A and a semiautomated software to measure the capillary density index (CDI) and fractal dimension (FD) at the superficial vascular plexus (SVP) and deep retinal vascular plexus (DVP). We collected data on histories of patients' glycated hemoglobin A1c, hypertension, hyperlipidemia, smoking, and renal impairment. The CDI and FD at the SVP and DVP for each severity level of DR and the association of systemic risk factors vs the CDI and FD. The mean (SD) glycated hemoglobin A1c of the 50 patients (26 men and 24 women; 35 Chinese; mean [SD] age, 59.5 [8.9] years) was 7.9% (1.7%). The mean (SD) CDI at the SVP decreased from 0.358 (0.017) in patients with no DR to 0.338 (0.012) in patients with proliferative DR (P < .001) and at the DVP decreased in patients with no DR from 0.361 (0.019) to 0.345 (0.020) in patients with proliferative DR (P = .04). The mean (SD) FD at the SVP increased from 1.53 (0.05) in patients with no DR to 1.60 (0.05) in patients with proliferative DR (P < .01) and at the DVP increased from 1.55 (0.06) in patients with no DR to 1.61 (0.05) in patients with proliferative DR (P = .02). For systemic risk factors, hyperlipidemia (odds ratio [OR], 9.82; 95% CI, 6.92-11.23; P < .001), smoking (OR, 10.90; 95% CI, 8.23-12.34; P < .001), and renal impairment (OR, 3.72; 95% CI, 1.80-4.81; P = .05) were associated with reduced CDI, while increased glycated hemoglobin A1c (≥8%) (OR, 8.77; 95% CI, 5.23-10.81; P < .01) and renal impairment (OR, 10.30; 95% CI, 8.21-11.91; P < .001) were associated with increased FD. Optical coherence tomographic angiography is a novel imaging modality to quantify the retinal capillary microvasculature in patients with diabetes. It can be potentially used in interventional trials to study the effect of systemic risk factors on the microvasculature that was previously not accessible in a noninvasive manner. The relevance of these findings relative to visual acuity, however, remains largely unknown at this time.

  12. Association of brain abscess with a mycotic aneurysm of the contralateral internal carotid artery in a patient of cyanotic heart disease

    PubMed Central

    Bansal, Sumit; Borkar, Sachin A.; Mahapatra, Ashok K.

    2017-01-01

    Congenital cyanotic heart disease can lead to intra-cranial involvement. Authors report a very rare case of right intra-cerebral abscess diagnosed on computerized tomography (CT) scan and simultaneous presence of an aneurysm of the left internal carotid artery diagnosed on CT angiogram in a 15-year-old child with congenital cyanotic heart disease with recent onset left hemiparesis. Right cerebral abscess was tapped and left internal carotid aneurysm was planned to be followed up by giving antibiotics and serial angiograms, but he could not survive and died due to non-cranial cause. We conclude that cerebral angiography is necessary to diagnose cerebro-vascular complications, including infectious aneurysms, in cases presenting with unusual findings on neuroimaging study. Patient must undergo serial angiography while being on intravenous antibiotics. Intervention (either surgical or endovascular) should be considered if there are no signs of regression of size of aneurysm or in the presence of aneurysm rupture. We have not been able to find a similar case in the English literature. PMID:28484536

  13. Biology and Medicine Division annual report, 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-04-01

    This book briefly describes the activities of the Biology and Medicine Division of the Lawrence Berkeley Laboratory. During the past year the Donner Pavilion program on the treatment of arteriovenous malformations in the brain has chalked up very significant successes. The disease control rate has been high and objective measures of success using cerebral angiography have been established. The new high resolution positron emitting tomographic imager has been demonstrated to operate successfully. In the Radiation Biophysics program, the availability of higher mass ions up to uranium has allowed us cell and tissue studies in a radiation domain that is entirelymore » new. Using uranium beams, investigators have already made new and exciting findings that are described in the body of the report.« less

  14. Cost analysis of non-invasive fractional flow reserve derived from coronary computed tomographic angiography in Japan.

    PubMed

    Kimura, Takeshi; Shiomi, Hiroki; Kuribayashi, Sachio; Isshiki, Takaaki; Kanazawa, Susumu; Ito, Hiroshi; Ikeda, Shunya; Forrest, Ben; Zarins, Christopher K; Hlatky, Mark A; Norgaard, Bjarne L

    2015-01-01

    Percutaneous coronary intervention (PCI) based on fractional flow reserve (FFRcath) measurement during invasive coronary angiography (CAG) results in improved patient outcome and reduced healthcare costs. FFR can now be computed non-invasively from standard coronary CT angiography (cCTA) scans (FFRCT). The purpose of this study is to determine the potential impact of non-invasive FFRCT on costs and clinical outcomes of patients with suspected coronary artery disease in Japan. Clinical data from 254 patients in the HeartFlowNXT trial, costs of goods and services in Japan, and clinical outcome data from the literature were used to estimate the costs and outcomes of 4 clinical pathways: (1) CAG-visual guided PCI, (2) CAG-FFRcath guided PCI, (3) cCTA followed by CAG-visual guided PCI, (4) cCTA-FFRCT guided PCI. The CAG-visual strategy demonstrated the highest projected cost ($10,360) and highest projected 1-year death/myocardial infarction rate (2.4 %). An assumed price for FFRCT of US $2,000 produced equivalent clinical outcomes (death/MI rate: 1.9 %) and healthcare costs ($7,222) for the cCTA-FFRCT strategy and the CAG-FFRcath guided PCI strategy. Use of the cCTA-FFRCT strategy to select patients for PCI would result in 32 % lower costs and 19 % fewer cardiac events at 1 year compared to the most commonly used CAG-visual strategy. Use of cCTA-FFRCT to select patients for CAG and PCI may reduce costs and improve clinical outcome in patients with suspected coronary artery disease in Japan.

  15. Advances in imaging technologies for planning breast reconstruction

    PubMed Central

    Mohan, Anita T.

    2016-01-01

    The role and choice of preoperative imaging for planning in breast reconstruction is still a disputed topic in the reconstructive community, with varying opinion on the necessity, the ideal imaging modality, costs and impact on patient outcomes. Since the advent of perforator flaps their use in microsurgical breast reconstruction has grown. Perforator based flaps afford lower donor morbidity by sparing the underlying muscle provide durable results, superior cosmesis to create a natural looking new breast, and are preferred in the context of radiation therapy. However these surgeries are complex; more technically challenging that implant based reconstruction, and leaves little room for error. The role of imaging in breast reconstruction can assist the surgeon in exploring or confirming flap choices based on donor site characteristics and presence of suitable perforators. Vascular anatomical studies in the lab have provided the surgeon a foundation of knowledge on location and vascular territories of individual perforators to improve our understanding for flap design and safe flap harvest. The creation of a presurgical map in patients can highlight any abnormal or individual anatomical variance to optimize flap design, intraoperative decision-making and execution of flap harvest with greater predictability and efficiency. This article highlights the role and techniques for preoperative planning using the newer technologies that have been adopted in reconstructive clinical practice: computed tomographic angiography (CTA), magnetic resonance angiography (MRA), laser-assisted indocyanine green fluorescence angiography (LA-ICGFA) and dynamic infrared thermography (DIRT). The primary focus of this paper is on the application of CTA and MRA imaging modalities. PMID:27047790

  16. Coronary Computed Tomographic Angiography-Derived Fractional Flow Reserve for Therapeutic Decision Making.

    PubMed

    Tesche, Christian; Vliegenthart, Rozemarijn; Duguay, Taylor M; De Cecco, Carlo N; Albrecht, Moritz H; De Santis, Domenico; Langenbach, Marcel C; Varga-Szemes, Akos; Jacobs, Brian E; Jochheim, David; Baquet, Moritz; Bayer, Richard R; Litwin, Sheldon E; Hoffmann, Ellen; Steinberg, Daniel H; Schoepf, U Joseph

    2017-12-15

    This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD. The therapeutic strategy (optimal medical therapy alone vs revascularization) and the appropriate revascularization procedure (percutaneous coronary intervention vs coronary artery bypass grafting) were selected using cCTA-CT-FFR. Thirty-six patients (49%) had a functionally significant CAD based on ICA-FFR. cCTA-CT-FFR correctly identified a functionally significant CAD and the need of revascularization in 35 of 36 patients (97%). When revascularization was deemed indicated, the same revascularization procedure (32 percutaneous coronary interventions and 3 coronary artery bypass grafting) was chosen in 35 of 35 patients (100%). Overall, identical management strategies were selected in 73 of the 74 patients (99%). cCTA-CT-FFR shows excellent performance to identify patients with and without the need for revascularization and to select the appropriate revascularization strategy. cCTA-CT-FFR as a noninvasive "one-stop shop" has the potential to change diagnostic workflows and to directly inform therapeutic decision making in patients with suspected CAD. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Cost-effectiveness of digital subtraction angiography in the setting of computed tomographic angiography negative subarachnoid hemorrhage.

    PubMed

    Jethwa, Pinakin R; Punia, Vineet; Patel, Tapan D; Duffis, E Jesus; Gandhi, Chirag D; Prestigiacomo, Charles J

    2013-04-01

    Recent studies have documented the high sensitivity of computed tomography angiography (CTA) in detecting a ruptured aneurysm in the presence of acute subarachnoid hemorrhage (SAH). The practice of digital subtraction angiography (DSA) when CTA does not reveal an aneurysm has thus been called into question. We examined this dilemma from a cost-effectiveness perspective by using current decision analysis techniques. A decision tree was created with the use of TreeAge Pro Suite 2012; in 1 arm, a CTA-negative SAH was followed up with DSA; in the other arm, patients were observed without further imaging. Based on literature review, costs and utilities were assigned to each potential outcome. Base-case and sensitivity analyses were performed to determine the cost-effectiveness of each strategy. A Monte Carlo simulation was then conducted by sampling each variable over a plausible distribution to evaluate the robustness of the model. With the use of a negative predictive value of 95.7% for CTA, observation was found to be the most cost-effective strategy ($6737/Quality Adjusted Life Year [QALY] vs $8460/QALY) in the base-case analysis. One-way sensitivity analysis demonstrated that DSA became the more cost-effective option if the negative predictive value of CTA fell below 93.72%. The Monte Carlo simulation produced an incremental cost-effectiveness ratio of $83 083/QALY. At the conventional willingness-to-pay threshold of $50 000/QALY, observation was the more cost-effective strategy in 83.6% of simulations. The decision to perform a DSA in CTA-negative SAH depends strongly on the sensitivity of CTA, and therefore must be evaluated at each center treating these types of patients. Given the high sensitivity of CTA reported in the current literature, performing DSA on all patients with CTA negative SAH may not be cost-effective at every institution.

  18. Peripheral Vasculature: High-Temporal- and High-Spatial-Resolution Three-dimensional Contrast-enhanced MR Angiography1

    PubMed Central

    Haider, Clifton R.; Glockner, James F.; Stanson, Anthony W.; Riederer, Stephen J.

    2009-01-01

    Purpose: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material–enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction–like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). Materials and Methods: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27–53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. Results: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. Conclusion: The feasibility of performing high-diagnostic-quality time-resolved 3D contrast-enhanced MR angiography of the peripheral vasculature by using CAPR and eightfold accelerated 2D SENSE has been demonstrated. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081744/-/DC1 PMID:19789238

  19. Transapical aortic valve implantation without angiography: proof of concept.

    PubMed

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report confirms that this procedure is feasible and safe, and provides good results with low incidence of postoperative renal disorders. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement.

    PubMed

    Zimmerman, J B; Pizer, S M; Staab, E V; Perry, J R; McCartney, W; Brenton, B C

    1988-01-01

    Adaptive histogram equalization (AHE) and intensity windowing have been compared using psychophysical observer studies. Experienced radiologists were shown clinical CT (computerized tomographic) images of the chest. Into some of the images, appropriate artificial lesions were introduced; the physicians were then shown the images processed with both AHE and intensity windowing. They were asked to assess the probability that a given image contained the artificial lesion, and their accuracy was measured. The results of these experiments show that for this particular diagnostic task, there was no significant difference in the ability of the two methods to depict luminance contrast; thus, further evaluation of AHE using controlled clinical trials is indicated.

  1. CMT for materials science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinney, J.

    This session is comprised of two articles by John Kinney describing biomedical and other uses for computerized tomography. In the first article, Kinney describes the use of a three-dimensional x-ray tomographic microscope to image the trabecular bone architecture of the proximal tibias of rats in vivo. Research in this field may help to detect the earliest stages of hypoestrogenemic bone loss and may help to more rapidly test the effectiveness of new clinical treatments for this major public health problem. The second article describes recent advances in X-ray tomography using synchrotron radiation to evaluate microstructures in ceramic matrix composites, bonemore » loss in osteoporosis, and the development of carries lesions in teeth.« less

  2. PubMed Central

    FOUNTOULAKIS, E.N.; PAPADAKI, E.; PANAGIOTAKI, I.; GIANNIKAKI, E.; LAGOUDIANAKIS, G.; BIZAKIS, J.

    2011-01-01

    SUMMARY Haemangiopericytoma is a rare soft tissue tumour, with great histological variability and unpredictable clinical and biological behaviour. The precise cell type origin is uncertain. One third of haemangiopericytomas occur in the head and neck area, but only a few cases have been reported regarding localization at the parapharyngeal space. Herewith, case is presented of a 54-year-old female, referred to our Department due to a parapharyngeal space tumour with non-specific imaging characteristics. The patient underwent radical excision of the tumour with a trans-cervical sub-mandibular approach. The histolopathologic examination revealed a neoplasm with the characteristic features of haemangiopericytoma. One year later, during the scheduled follow-up, the computerized tomography scan showed no evidence of recurrence or residual disease. The pre-operative evaluation of a haemangiopericytoma must include a thorough imaging evaluation with computerized tomography and magnetic resonance imaging, even if results may not be specific for haemangiopericytoma. Angiography and pre-operative embolization may be performed in cases of large tumours with significant vascularity. The treatment of choice is radical excision. The follow-up includes clinical evaluation every 6 months and annual magnetic resonance imaging for at least 3 years. PMID:22058597

  3. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  4. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    PubMed

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  5. Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography.

    PubMed

    van Velsen, Evert F S; Niessen, Wiro J; de Weert, Thomas T; de Monyé, Cécile; van der Lugt, Aad; Meijering, Erik; Stokking, Rik

    2007-07-01

    Vessel image analysis is crucial when considering therapeutical options for (cardio-) vascular diseases. Our method, VAMPIRE (Vascular Analysis using Multiscale Paths Inferred from Ridges and Edges), involves two parts: a user defines a start- and endpoint upon which a lumen path is automatically defined, and which is used for initialization; the automatic segmentation of the vessel lumen on computed tomographic angiography (CTA) images. Both parts are based on the detection of vessel-like structures by analyzing intensity, edge, and ridge information. A multi-observer evaluation study was performed to compare VAMPIRE with a conventional method on the CTA data of 15 patients with carotid artery stenosis. In addition to the start- and endpoint, the two radiologists required on average 2.5 (SD: 1.9) additional points to define a lumen path when using the conventional method, and 0.1 (SD: 0.3) when using VAMPIRE. The segmentation results were quantitatively evaluated using Similarity Indices, which were slightly lower between VAMPIRE and the two radiologists (respectively 0.90 and 0.88) compared with the Similarity Index between the radiologists (0.92). The evaluation shows that the improved definition of a lumen path requires minimal user interaction, and that using this path as initialization leads to good automatic lumen segmentation results.

  6. Advanced cardiovascular imaging in Williams syndrome: Abnormalities, usefulness, and strategy for use.

    PubMed

    Hills, Jordan A; Zarate, Yuri A; Danylchuk, Noelle R; Lepard, Tiffany; Chen, Jean Chi-Jen; Collins, Ronnie Thomas

    2017-05-01

    Extracardiac arterial stenoses are not uncommon in Williams syndrome (WS); however, data on the utility of advanced cardiovascular imaging (CVI) to assess these stenoses are lacking. We retrospectively reviewed the frequency, indication, and diagnostic outcomes of CVI modalities performed in patients with WS evaluated at a single institution between 2001 and 2014. Data were collected and analyzed from 34 patients (56% female) who underwent CVI during the study period. The median age was 10 years (range 1.8-33 years). Excluding echocardiograms, 78 CVI studies "advanced" were performed in the 34 patients (mean 2.3 studies/patient). The most common advanced CVI was renal ultrasound with Doppler (29/34, 85%), followed by computed tomographic angiography (13/34, 38%) and magnetic resonance angiography in (9/34, 26%). Abnormalities were detected in 62% of patients (21/34). For the 20 patients in whom advanced CVI were performed for defined clinical indications, the rate of abnormalities were 73, 70, 57, and 100% when performed for anatomic delineation (15 patients), hypertension (10 patients), bruits (7 patients), and/or decreased peripheral pulses (2 patients), respectively. Advanced CVI in patients with WS reveals abnormalities in the majority of cases, and physical exam findings frequently indicate abnormalities on advanced CVI. © 2017 Wiley Periodicals, Inc.

  7. Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors.

    PubMed

    Bhatti, Aftab A; Chugtai, Aamir; Haslam, Philip; Talbot, David; Rix, David A; Soomro, Naeem A

    2005-11-01

    To prospectively compare the accuracy of multislice spiral computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) in evaluating the renal vascular anatomy in potential living renal donors. Thirty-one donors underwent multislice spiral CTA and gadolinium-enhanced MRA. In addition to axial images, multiplanar reconstruction and maximum intensity projections were used to display the renal vascular anatomy. Twenty-four donors had a left laparoscopic donor nephrectomy (LDN), whereas seven had right open donor nephrectomy (ODN); LDN was only considered if the renal vascular anatomy was favourable on the left. CTA and MRA images were analysed by two radiologists independently. The radiological and surgical findings were correlated after the surgery. CTA showed 33 arteries and 32 veins (100% sensitivity) whereas MRA showed 32 arteries and 31 veins (97% sensitivity). CTA detected all five accessory renal arteries whereas MRA only detected one. CTA also identified all three accessory renal veins whereas MRA identified two. CTA had a sensitivity of 97% and 47% for left lumbar and left gonadal veins, whereas MRA had a sensitivity of 74% and 46%, respectively. Multislice spiral CTA with three-dimensional reconstruction was more accurate than MRA for both renal arterial and venous anatomy.

  8. New congenital coronary artery anomaly - double supply of single left anterior descending coronary artery from the left and right coronary sinuses: a case report.

    PubMed

    Daralammouri, Yunis; Ghannam, Malik; Lauer, Bernward

    2016-08-02

    A normal anatomy of coronary arteries is important to have adequate cardiac muscle blood supply especially during extraneous physical activities. This case report describes a rare coronary anomaly in which the accessory coronary artery arose from the right coronary artery, reentered the left anterior descending coronary artery, and then ran as a single vessel. We present a case of a coronary anomaly in a 47-year-old white man who presented with atypical angina. Computed tomographic angiography and coronary angiography showed a variant of dual left anterior descending coronary artery not previously described. Our patient's accessory coronary artery arose from his right coronary artery. It took an intramuscular course beneath the right ventricular outflow tract in the interventricular septal area to the anterior interventricular sulcus, giving off septal perforators that reentered his medial left anterior descending coronary artery. Both vessels ran after the anastomosis in the anterior interventricular sulcus as a single vessel. We propose that this anomaly represents a new variant of coronary artery anomaly. This coronary artery anomaly does not cause ischemia. Recognition of this coronary anomaly is important in patients undergoing percutaneous coronary intervention or coronary artery bypass graft operations.

  9. Fractional flow reserve based on computed tomography: an overview.

    PubMed

    Secchi, Francesco; Alì, Marco; Faggiano, Elena; Cannaò, Paola Maria; Fedele, Marco; Tresoldi, Silvia; Di Leo, Giovanni; Auricchio, Ferdinando; Sardanelli, Francesco

    2016-04-28

    Computed tomography coronary angiography (CTCA) is a technique proved to provide high sensitivity and negative predictive value for the identification of anatomically significant coronary artery disease (CAD) when compared with invasive X-ray coronary angiography. While the CTCA limitation of a ionizing radiation dose delivered to patients is substantially overcome by recent technical innovations, a relevant limitation remains the only anatomical assessment of coronary stenoses in the absence of evaluation of their functional haemodynamic significance. This limitation is highly important for those stenosis graded as intermediate at the anatomical assessment. Recently, non-invasive methods based on computational fluid dynamics were developed to calculate vessel-specific fractional flow reserve (FFR) using data routinely acquired by CTCA [computed tomographic fractional flow reserve (CT-FFR)]. Here we summarize methods for CT-FFR and review the evidence available in the literature up to June 26, 2016, including 16 original articles and one meta-analysis. The perspective of CT-FFR may greatly impact on CAD diagnosis, prognostic evaluation, and treatment decision-making. The aim of this review is to describe technical characteristics and clinical applications of CT-FFR, also in comparison with catheter-based invasive FFR, in order to make a cost-benefit balance in terms of clinical management and patient's health.

  10. Totally Endoscopic Coronary Artery Bypass for Anomalous Origin of Right Coronary Artery.

    PubMed

    Kuo, Chia-Cheng; Hsing, Chung-Hsi; Cheng, Bor-Chih

    2017-01-01

    Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Robotic totally endoscopic coronary artery bypass for isolated ostial stenosis of the left coronary artery

    PubMed Central

    Kuo, Chia-Cheng; Hsing, Chung-Hsi; Chen, Chun-I; Lee, Chen-Hui

    2017-01-01

    Isolated ostial stenosis (IOS) is a rare disease that encroaches on aorto-coronary junction of uncertain etiology. All distal coronary vessels present normally. IOS occurs predominantly in premenopausal young women with few risk factors for atherosclerotic disease. Here, we report a 40-year-old woman who had experienced crescendo angina for 4 months. Surgical revascularization was achieved by robotic totally endoscopic coronary artery bypass (TECAB) with left internal thoracic artery (LITA) graft. She resumed her daily tasks without difficulties 1 week after the operation. Postoperative computed tomographic angiography disclosed good opacification of the LITA graft and distal runoff. Robotic TECAB is a potentially feasible alternative for IOS patients, particularly in premenopausal young woman, with obvious benefits of cosmetic appearance and speedy recovery. PMID:29312766

  12. Partial anomalous pulmonary venous connection with suspected pulmonary hypertension in a cat.

    PubMed

    Nicolson, Geoff; Daley, Michael; Makara, Mariano; Beijerink, Niek

    2015-12-01

    Partial anomalous pulmonary venous connection has previously been reported in the dog, but never in a cat. A 14-month-old Devon Rex cat was presented for echocardiography to evaluate a heart murmur noticed during a routine examination. The pertinent finding was right-sided cardiomegaly in the absence of an atrial septal defect or tricuspid regurgitation; pulmonary hypertension was suspected. A thoracic computed tomographic angiography study identified a partial anomalous pulmonary venous connection with the lobar veins of the left caudal, right middle, right caudal and accessory lung lobes draining into the caudal vena cava. The resultant volume overload is an easily overlooked differential diagnosis for right-sided cardiac enlargement. This is the first such report of this anomaly in a cat. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The neurologic evaluation of patients with low-tension glaucoma.

    PubMed

    Corbett, J J; Phelps, C D; Eslinger, P; Montague, P R

    1985-08-01

    One hypothesized cause of low-tension glaucoma is chronic or intermittent ischemia of the optic nerve. Since the optic nerve and brain are both parts of the central nervous system and share a common blood supply, the authors wondered if patients with low-tension glaucoma might also have clinical or radiographic evidence of cerebral atrophy. In this study, 27 patients with low-tension glaucoma were examined using neurobehavioral testing, electroencephalography, computerized tomographic scan, neurological history, and physical examination. In only a small number of patients were these tests abnormal. However, 12 of the 27 patients gave a history of common or classic migraine. This unexpected finding raises the possibility that migraine-related ischemia might be the pathogenic mechanism in some cases of low-tension glaucoma.

  14. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  15. Role of time-resolved-CTA in intracranial arteriovenous malformation evaluation at 128-slice CT in comparison with digital subtraction angiography.

    PubMed

    Singh, Rupinder; Gupta, Vivek; Ahuja, Chirag; Kumar, Ajay; Mukherjee, Kanchan K; Khandelwal, Niranjan

    2018-06-01

    Introduction The present study aimed to evaluate the accuracy of time-resolved-computed tomographic angiography (TR-CTA) on a 128-slice CT scanner vis-à-vis cerebral digital subtraction angiography (DSA) in defining the morphological and haemodynamic characteristics of cerebral arteriovenous malformation (AVM). Methods Twenty-one patients (age range 10-46, mean 24.8 years) with clinical suspicion of AVM and three patients (age range 23-35, mean 24.3 years) with diagnosed AVM who were on follow-up underwent DSA and TR-CTA, on average 1.5 days apart. Three independent neuroradiologists analysed both studies in a blinded fashion based on the following parameters: AVM location, arterial feeder territories, venous drainage pattern, nidus flow characteristics, venous outflow obstruction, arterial feeder enlargement, external carotid artery feeder, location of aneurysm if any, leptomeningeal and transdural recruitment, neoangiogenesis, and pseudophlebitic pattern. Results The TR-CTA correctly demonstrated AVM in all 21 positive cases. It concordantly detected location (21/21), venous drainage pattern (21/21), nidus flow characteristics (21/21), and the venous outflow obstruction (9/9). However, discordance was seen in the demonstration of the arterial feeder (2/45) ( p = 0.49), arterial enlargement (13/17) ( p = 0.103), external carotid artery feeder (0/1), aneurysmal location (3/5) ( p = 0.40), leptomeningeal recruitment (1/3) ( p = 0.40), neoangiogenesis (0/4) ( p = 0.028) and in the pseudophlebitic pattern (2/5) ( p = 0.167) demonstration. Conclusions The results suggest that TR-CTA can provide the important features of cerebral AVM which are required in patient management.

  16. Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

    PubMed Central

    Jehle, Dietrich; Chae, Floria; Wai, Jonathan; Cloud, Sam; Pierce, David; Meyer, Michael

    2012-01-01

    CT angiography (CTA) has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP) misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D) reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms. PMID:22593806

  17. Usefulness of Cone-Beam Computed Tomography During Ultraselective Transcatheter Arterial Chemoembolization for Small Hepatocellular Carcinomas that Cannot be Demonstrated on Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Okuda, Miho

    2009-03-15

    This study evaluated the usefulness of cone-beam computed tomography (CBCT) during ultraselective transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCC) that could not be demonstrated on angiography. Twenty-eight patients with 33 angiographically occult tumors (mean diameter 1.3 {+-} 0.3 cm) were enrolled in the study. The ability of CBCT during arterial portography (CBCTAP), during hepatic arteriography (CBCTHA), and after iodized oil injection (LipCBCT) to detect HCC lesions was retrospectively analyzed. The technical success of TACE was divided into three grades: complete (the embolized area included the entire tumor with at least a 5-mm wide margin), adequate (the embolized area includedmore » the entire tumor but without a 5-mm wide margin in parts), and incomplete (the embolized area did not include the entire tumor) according to computed axial tomographic (CAT) images obtained 1 week after TACE. Local tumor progression was also evaluated. CBCTAP, CBCTHA, and LipCBCT detected HCC lesions in 93.9% (31 of 33), 96.7% (29 of 30), and 100% (29 of 29) of patients, respectively. A single branch was embolized in 28 tumors, and 2 branches were embolized in five tumors. Twenty-seven tumors (81.8%) were classed as complete, and 6 (18.2%) were classed as adequate. None of the tumors were classed as incomplete. Twenty-five tumors (75.8%) had not recurred during 12.0 {+-} 6.2 months. Eight tumors (24.2%), 5 (18.5%) of 27 complete success and 3 (50%) of 6 adequate success, recurred during 10.1 {+-} 6.2 months. CBCT during TACE is useful in detecting and treating small HCC lesions that cannot not be demonstrated on angiography.« less

  18. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial.

    PubMed

    Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with /=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).

  19. Central Core Laboratory versus Site Interpretation of Coronary CT Angiography: Agreement and Association with Cardiovascular Events in the PROMISE Trial.

    PubMed

    Lu, Michael T; Meyersohn, Nandini M; Mayrhofer, Thomas; Bittner, Daniel O; Emami, Hamed; Puchner, Stefan B; Foldyna, Borek; Mueller, Martin E; Hearne, Steven; Yang, Clifford; Achenbach, Stephan; Truong, Quynh A; Ghoshhajra, Brian B; Patel, Manesh R; Ferencik, Maros; Douglas, Pamela S; Hoffmann, Udo

    2018-04-01

    Purpose To assess concordance and relative prognostic utility between central core laboratory and local site interpretation for significant coronary artery disease (CAD) and cardiovascular events. Materials and Methods In the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) trial, readers at 193 North American sites interpreted coronary computed tomographic (CT) angiography as part of the clinical evaluation of stable chest pain. Readers at a central core laboratory also interpreted CT angiography blinded to clinical data, site interpretation, and outcomes. Significant CAD was defined as stenosis greater than or equal to 50%; cardiovascular events were defined as a composite of cardiovascular death or myocardial infarction. Results In 4347 patients (51.8% women; mean age ± standard deviation, 60.4 years ± 8.2), core laboratory and site interpretations were discordant in 16% (683 of 4347), most commonly because of a finding of significant CAD by site but not by core laboratory interpretation (80%, 544 of 683). Overall, core laboratory interpretation resulted in 41% fewer patients being reported as having significant CAD (14%, 595 of 4347 vs 23%, 1000 of 4347; P < .001). Over a median follow-up period of 25 months, 1.3% (57 of 4347) sustained myocardial infarction or cardiovascular death. The C statistic for future myocardial infarction or cardiovascular death was 0.61 (95% confidence interval [CI]: 0.54, 0.68) for the core laboratory and 0.63 (95% CI: 0.56, 0.70) for the sites. Conclusion Compared with interpretation by readers at 193 North American sites, standardized core laboratory interpretation classified 41% fewer patients as having significant CAD. © RSNA, 2017 Online supplemental material is available for this article. Clinical trial registration no. NCT01174550.

  20. Cerebral infarction caused by traumatic carotid artery dissection.

    PubMed

    Bayır, Ayşegül; Aydoğdu Kıreşi, Demet; Söylemez, Ali; Demirci, Osman

    2012-07-01

    Traumatic carotid artery dissection, if not diagnosed and treated early, is a serious problem with permanent neurological deficit and a high mortality rate of up to 40%. We present a case with delayed diagnosis of traumatic carotid artery dissection in a 21-year-old female. While there were no ischemic infarct findings on the admission cerebral computerized tomography (CT), such findings were observed on two cerebral CTs taken because of the left hemiplegia noticed seven days later when the patient regained consciousness. The patient was referred to our emergency service, and definitive diagnosis was achieved with arterial Doppler ultrasonography, cerebral magnetic resonance imaging (MRI), diffusion MRI, and MR angiography. We did not consider invasive treatment since the neurological damage was permanent and dissection grade was IV according to angiography findings. The case was discharged within a week and physiotherapy was advised. Despite the advances in diagnostic methods, diagnosis of traumatic carotid artery dissection is still missed or delayed, as in the case presented here. Early diagnosis can ameliorate permanent neurological damage or even prevent it. However, the vital factors for early diagnosis are the obtained anamnesis leading to appropriate radiological examinations, detailed physical examination and high clinical suspicion.

  1. Inferior gluteal artery pseudoaneurysm related to intramuscular injection

    PubMed Central

    Saad, Paulo Fernandes; Saad, Karen Ruggeri; Armstrong, Dinani Matoso Fialho de Oliveira; Soares, Bruno Leonardo de Freitas; de Almeida, Paulo Henrique Freitas; Razuk Filho, Álvaro

    2014-01-01

    INTRODUCTION Gluteal artery pseudoaneurysms are rare, yet the most common in cases involving the superior gluteal artery. Pseudoaneurysms of the inferior gluteal artery are uncommon and are often related to blunt or penetrating trauma, infections and fractures of the pelvis. PRESENTATION OF CASE The authors present a case of pseudoaneurysm of the inferior gluteal artery related to an iatrogenic injury due to intramuscular injection of medication, which was treated with selective embolization of the artery during angiography. DISCUSSION The most common manifestation of an inferior gluteal artery pseudoaneurysm is the presence of a painful mass in the buttock that may or may not be associated with neurological symptoms due to compression of the sciatic nerve. Ultrasound with color Doppler and computerized tomography with multi-detectors are useful non-invasive tools for diagnosis. However, both diagnosis and therapy are facilitated by catheter angiography. CONCLUSION This case cautions that although pseudoaneurysms are rare, pseudoaneurysms of the inferior gluteal artery require a high index of suspicion and careful physical examination by the physician in order to avoid misdiagnosis. It also illustrates the usefulness of a minimally invasive modality for treatment of these lesions. PMID:25506847

  2. Instant wireless transmission of radiological images using a personal digital assistant phone for emergency teleconsultation.

    PubMed

    Kim, Dong-Keun; Yoo, Sun K; Kim, Sun H

    2005-01-01

    The instant transmission of radiological images may be important for making rapid clinical decisions about emergency patients. We have examined an instant image transfer system based on a personal digital assistant (PDA) phone with a built-in camera. Images displayed on a picture archiving and communication systems (PACS) monitor can be captured by the camera in the PDA phone directly. Images can then be transmitted from an emergency centre to a remote physician via a wireless high-bandwidth network (CDMA 1 x EVDO). We reviewed the radiological lesions in 10 normal and 10 abnormal cases produced by modalities such as computerized tomography (CT), magnetic resonance (MR) and digital angiography. The images were of 24-bit depth and 1,144 x 880, 1,120 x 840, 1,024 x 768, 800 x 600, 640 x 480 and 320 x 240 pixels. Three neurosurgeons found that for satisfactory remote consultation a minimum size of 640 x 480 pixels was required for CT and MR images and 1,024 x 768 pixels for angiography images. Although higher resolution produced higher clinical satisfaction, it also required more transmission time. At the limited bandwidth employed, higher resolutions could not be justified.

  3. Multidetector computed tomographic pulmonary angiography in patients with a high clinical probability of pulmonary embolism.

    PubMed

    Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D

    2016-01-01

    ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely exclude PE in patients with a high clinical pretest probability. © 2015 International Society on Thrombosis and Haemostasis.

  4. European Society of Cardiology-Recommended Coronary Artery Disease Consortium Pretest Probability Scores More Accurately Predict Obstructive Coronary Disease and Cardiovascular Events Than the Diamond and Forrester Score: The Partners Registry.

    PubMed

    Bittencourt, Marcio Sommer; Hulten, Edward; Polonsky, Tamar S; Hoffman, Udo; Nasir, Khurram; Abbara, Suhny; Di Carli, Marcelo; Blankstein, Ron

    2016-07-19

    The most appropriate score for evaluating the pretest probability of obstructive coronary artery disease (CAD) is unknown. We sought to compare the Diamond-Forrester (DF) score with the 2 CAD consortium scores recently recommended by the European Society of Cardiology. We included 2274 consecutive patients (age, 56±13 years; 57% male) without prior CAD referred for coronary computed tomographic angiography. Computed tomographic angiography findings were used to determine the presence or absence of obstructive CAD (≥50% stenosis). We compared the DF score with the 2 CAD consortium scores with respect to their ability to predict obstructive CAD and the potential implications of these scores on the downstream use of testing for CAD, as recommended by current guidelines. The DF score did not satisfactorily fit the data and resulted in a significant overestimation of the prevalence of obstructive CAD (P<0.001); the CAD consortium basic score had no significant lack of fitness; and the CAD consortium clinical provided adequate goodness of fit (P=0.39). The DF score had a lower discrimination for obstructive CAD, with an area under the receiver-operating characteristics curve of 0.713 versus 0.752 and 0.791 for the CAD consortium models (P<0.001 for both). Consequently, the use of the DF score was associated with fewer individuals being categorized as requiring no additional testing (8.3%) compared with the CAD consortium models (24.6% and 30.0%; P<0.001). The proportion of individuals with a high pretest probability was 18% with the DF and only 1.1% with the CAD consortium scores (P<0.001) CONCLUSIONS: Among contemporary patients referred for noninvasive testing, the DF risk score overestimates the risk of obstructive CAD. On the other hand, the CAD consortium scores offered improved goodness of fit and discrimination; thus, their use could decrease the need for noninvasive or invasive testing while increasing the yield of such tests. © 2016 American Heart Association, Inc.

  5. A computerized tomography system for transcranial ultrasound imaging.

    PubMed

    Tang, Sai Chun; Clement, Gregory T

    Hardware for tomographic imaging presents both challenge and opportunity for simplification when compared with traditional pulse-echo imaging systems. Specifically, point diffraction tomography does not require simultaneous powering of elements, in theory allowing just a single transmit channel and a single receive channel to be coupled with a switching or multiplexing network. In our ongoing work on transcranial imaging, we have developed a 512-channel system designed to transmit and/or receive a high voltage signal from/to arbitrary elements of an imaging array. The overall design follows a hierarchy of modules including a software interface, microcontroller, pulse generator, pulse amplifier, high-voltage power converter, switching mother board, switching daughter board, receiver amplifier, analog-to-digital converter, peak detector, memory, and USB communication. Two pulse amplifiers are included, each capable of producing up to 400Vpp via power MOSFETS. Switching is based around mechanical relays that allow passage of 200V, while still achieving switching times of under 2ms, with an operating frequency ranging from below 100kHz to 10MHz. The system is demonstrated through ex vivo human skulls using 1MHz transducers. The overall system design is applicable to planned human studies in transcranial image acquisition, and may have additional tomographic applications for other materials necessitating a high signal output.

  6. Multi-dimensional distribution of near-field ionospheric disturbances produced by the 2015 Mw7.8 Nepal earthquake

    NASA Astrophysics Data System (ADS)

    Tang, Jun; Yuan, Yunbin

    2017-10-01

    Ionospheric anomalies possibly associated with large earthquakes, particularly coseismic ionospheric disturbances, have been detected by global positioning system (GPS). A large Nepal earthquake with magnitude Mw7.8 occurred on April 25, 2015. In this paper, we investigate the multi-dimensional distribution of near-field coseismic ionospheric disturbances (CIDs) using total electron content (TEC) and computerized ionospheric tomography (CIT) from regional GPS observational data. The results show significant ionospheric TEC disturbances and interesting multi-dimensional structures around the main shock. Regarding the TEC changes, coseismic ionospheric disturbances occur approximately 10-20 min after the earthquake northeast and northwest of epicentre. The maximum ridge-to-trough amplitude of CIDs is up to approximately 0.90 TECU/min. Propagation velocities of the TEC disturbances are 1.27 ± 0.06 km/s and 1.91 ± 0.38 km/s. It is believed that the ionospheric disturbances are triggered by acoustic and Rayleigh waves. Tomographic results show that the three-dimensional distribution of ionospheric disturbances obviously increases at an altitude of 300 km above the surrounding epicentre, predominantly in the entire region between 200 km and 400 km. Significant ionospheric disturbances appear at 06:30 UT from tomographic images. This study reveals characteristics of an ionospheric anomaly caused by the Nepal earthquake.

  7. Osteomyocutaneous fibular flap harvesting: Computer-assisted planning of perforator vessels using Computed Tomographic Angiography scan and cutting guide.

    PubMed

    Battaglia, Salvatore; Maiolo, Vincenzo; Savastio, Gabriella; Zompatori, Maurizio; Contedini, Federico; Antoniazzi, Elisa; Cipriani, Riccardo; Marchetti, Claudio; Tarsitano, Achille

    2017-10-01

    Mandibular reconstruction performed after virtual planning has become more common during recent years. The gold standard for extensive mandibular reconstruction is of course a fibular free flap. In designing an osteomyocutaneous fibula flap, poor planning, aberrant anatomy and/or inadequate perforator vessels are the most frequent causes of complications and may force the surgeon to modify the flap design, explore the contralateral leg or harvest an additional microvascular flap. The goal of our study was to pre-operatively evaluate the vascular anatomy of the fibula and localize the cutaneous perforator vessels, so to create the fibular cutting guide based on the position of the cutaneous perforator and safely harvest the reconstructive flap. Twenty consecutive patients who were candidates for mandibular reconstruction using a fibular microvascular free flap were enrolled in this study between January 2016 and August 2016. The patients were preoperatively assessed with a Computed Tomographic scan of head and neck and with a Computed Tomographic Angiography (CTA) scan of the lower limbs to evaluate the vascular anatomy of the fibula. Virtual planning was carried out for all patients. The fibular cutting guide was based on the position of the perforator cutaneous vessels, which were used to harvest the cutaneous part of the flap. Preoperative CT measurements were performed in order to identify the cutaneous perforators on the patients' skin. Intraoperative checking was performed to evaluate the accuracy of the perforators' position and the reproducibility of the virtual planning. In 5 patients out of 20 (25%), anatomical anomalies were discovered, without clinical evidence. The perforator vessels were localized in all patients. The average difference between the CTA and the intraoperative perforator localization was 1 mm (range 0-2 mm). Fibular cutting guide was positioned and fitted the anatomy of the patients in all treated patients. This allowed us to perform the planned segmentation of the fibula, obtaining the correct number of segments. In all cases, flap insetting was carried out and skin paddle was positioned as preoperatively planned. Neither donor site complications nor flap complications occurred. Preoperative evaluation of the legs using CTA, in patients who undergo an osteomyocutaneous fibular free flap for mandibular reconstruction, is a valuable approach to reduce altered-anatomy related complications and to improve the accuracy and outcomes of the reconstruction, especially in reconstructions of complex defects. In these cases, a soft tissue-based cutting guide can be planned based on the perforator vessels of the skin paddle, minimizing the harvesting risks of vascular lesions. Further studies and longer follow-ups are needed to evaluate the long-term outcomes and advantages of this procedure. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.

    PubMed

    Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph

    2004-12-01

    Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004

  9. Cerebral Venous Thrombosis and Pulmonary Embolism with Prothrombin G20210A Gene Mutation.

    PubMed

    Dagli, Canan Eren; Koksal, Nurhan; Guler, Selma; Gelen, Mehmet Emin; Atilla, Nurhan; Tuncel, Deniz

    2010-04-01

    A 25-year-old man presented with symptoms of syncope, cough, headache and hemoptysis. Cranial MR and venography showed thrombus formation in the right transverse sinus and superior sagittal sinus. Computed tomographic pulmonary angiography (CTPA) showed an embolic thrombus in the right pulmonary truncus and lung abscess. The patient was young, and there were no signs of lower extremity deep venous thrombosis or other major risk factors for pulmonary embolism (PE) including cardiac anomaly. The only risk factor we were able to identify was the presence of the prothrombin G20210A gene mutation. Anticoagulant treatment with oral warfarin (10 mg daily) and imipenem (4X500 mg) was started. The patient was hospitalized for antibiotic and anticoagulation therapies for three weeks and was discharged on lifelong treatment with warfarin (5 mg daily).

  10. Use of radiologic modalities in coccidioidal meningitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.

    1981-01-01

    The diagnostic utility of pentetate indium trisodium CSF studies, technetium Tc 99m brain scans, and computerized tomographic (CT) scans was evaluated in eight patients in whom coccidioidal meningitis developed following a dust storm in the Central Valley of California. The 111In flow studies and the CT scans demonstrated hydrocephalus in five patients with clinical findings suggesting this complication. Ventriculitis has not previously been diagnosed before death in patients with coccidioidal meningitis; however, it was demonstrated in two patients by the technetium Tc 99m brain scan. The finding that communicating hydrocephalus occurs early in meningitis and interferes with CSF flow intomore » infected basilar regions has important therapeutic implications in that antifungal agents injected into the lumbar subarachnoid space may not reach these regions.« less

  11. Experience with single photon emission computerized tomography (SPECT) in follow-up of sternotomy healing.

    PubMed

    Harjula, A; Järvinen, A; Mattila, S; Porkka, L

    1985-01-01

    Single photon emission computerized tomography (SPECT) was performed thrice in ten patients undergoing open-heart surgery--preoperatively and 2 and 12 weeks postoperatively. The operations were done for ischemic heart disease (5), aortic valvular stenosis (2), aortic valvular insufficiency (1), leaking mitral prosthetic valve (1) and combined aortic and mitral valvular stenosis and insufficiency (1). The healing process in the longitudinally divided sternum was evaluated from the SPECT study. Four conventional static images in two dimensions were registered in anteroposterior, posteroanterior and left and right lateral projections. A tomographic study was done. Quantitative analyses were performed. The ratio of the sternal counts to the counts from a thoracic vertebra was calculated for use as a reference. The activity ratios showed a similar pattern in six cases, with initial increases and at 12 weeks slight decrease compared with the preoperative values. In two cases the activity was still increasing after 12 postoperative weeks. One patient, with sternotomy also one year previously, showed only slightly increased activity. The activity at the areas of the sternal wires was increased in six cases. The study thus revealed differing patterns of isotope uptake, although recovery was uneventful in all patients. The differences may reflect the possibility that the operative course and the preoperative clinical status can influence the healing mechanisms.

  12. Improving perceptions of empathy in patients undergoing low-yield computerized tomographic imaging in the emergency department.

    PubMed

    Lin, Michelle P; Probst, Marc A; Puskarich, Michael A; Dehon, Erin; Kuehl, Damon R; Wang, Ralph C; Hess, Erik P; Butler, Katie; Runyon, Michael S; Wang, Hao; Courtney, D Mark; Muckley, Brandon; Hobgood, Cherri D; Hall, Cassandra L; Kline, Jeffrey A

    2018-04-01

    We assessed emergency department (ED) patient perceptions of how physicians can improve their language to determine patient preferences for 11 phrases to enhance physician empathy toward the goal of reducing low-value advanced imaging. Multi-center survey study of low-risk ED patients undergoing computerized tomography (CT) scanning. We enroled 305 participants across nine sites. The statement "I have carefully considered what you told me about what brought you here today" was most frequently rated as important (88%). The statement "I have thought about the cost of your medical care to you today" was least frequently rated as important (59%). Participants preferred statements indicating physicians had considered their "vital signs and physical examination" (86%), "past medical history" (84%), and "what prior research tells me about your condition" (79%). Participants also valued statements conveying risks of testing, including potential kidney injury (78%) and radiation (77%). The majority of phrases were identified as important. Participants preferred statements conveying cognitive reassurance, medical knowledge and risks of testing. Our findings suggest specific phrases have the potential to enhance ED patient perceptions of physician empathy. Further research is needed to determine whether statements to convey empathy affect diagnostic testing rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Multiphase contrast medium injection for optimization of computed tomographic coronary angiography.

    PubMed

    Budoff, Matthew Jay; Shinbane, Jerold S; Child, Janis; Carson, Sivi; Chau, Alex; Liu, Stephen H; Mao, SongShou

    2006-02-01

    Electron beam angiography is a minimally invasive imaging technique. Adequate vascular opacification throughout the study remains a critical issue for image quality. We hypothesized that vascular image opacification and uniformity of vascular enhancement between slices can be improved using multiphase contrast medium injection protocols. We enrolled 244 consecutive patients who were randomized to three different injection protocols: single-phase contrast medium injection (Group 1), dual-phase contrast medium injection with each phase at a different injection rate (Group 2), and a three-phase injection with two phases of contrast medium injection followed by a saline injection phase (Group 3). Parameters measured were aortic opacification based on Hounsfield units and uniformity of aortic enhancement at predetermined slices (locations from top [level 1] to base [level 60]). In Group 1, contrast opacification differed across seven predetermined locations (scan levels: 1st versus 60th, P < .05), demonstrating significant nonuniformity. In Group 2, there was more uniform vascular enhancement, with no significant differences between the first 50 slices (P > .05). In Group 3, there was greater uniformity of vascular enhancement and higher mean Hounsfield units value across all 60 images, from the aortic root to the base of the heart (P < .05). The three-phase injection protocol improved vascular opacification at the base of the heart, as well as uniformity of arterial enhancement throughout the study.

  14. Features of central serous chorioretinopathy presenting at a tertiary care hospital in Lahore.

    PubMed

    Jamil, Ahmad Zeeshan; Mirza, Khurram Azam; Qazi, Zaheer Uddin Aqil; Iqbal, Wasim; Khaliq, Javed; Fawad-ur-Rahman; Ahmed, Arslan

    2013-04-01

    To evaluate the clinical, angiographic and optical coherence tomographic features of central serous chorioretinopathy in patients presenting at a tertiary care centre in Lahore. The observational study was conducted at the Layton Rehmatulla Benevolent Trust Eye and Cancer Hospital Lahore from July 15, 2010 to December 15, 2011. Patients who had received prior treatment for the condition and allergy to fluorescein were excluded. There were 86 eyes of 64 adult patients with central serous chorioretinopathy. The following data was recorded: history, signs and symptoms, best corrected visual acuity, fundus fluorescein angiography, and central macular thickness measurement with optical coherence tomography. Data was analyzed using SPSS 17. Mean age of patients who presented during the study duration was 39.52 +/- 8.85 years.There were 53 (82.8%) males and 11(17.2%) females. Of the total, 42 (65.6%) cases had unilateral and 22 (34.4%) cases had bilateral involvement. Chronic central serous chorioretinopathy was seen in 27 (42.2%) cases while 37 (57.8%) cases were acute presentations. Retinal pigment epithelial detachment was observed in 29 (45.3%) cases. On fundus fluorescein angiography, there were 62 (72.1%) eyes that showed ink blot pattern. Median visual acuity at presentation was 0.25. Median central macular thickness at presentation was 550.5micro. Central serous chorioretinopathy in the study sample was associated with pigment epithelial detachment, bilateral involvement, and presence of systemic diseases.

  15. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  16. Best-Quality Vessel Identification Using Vessel Quality Measure in Multiple-Phase Coronary CT Angiography.

    PubMed

    Hadjiiski, Lubomir; Liu, Jordan; Chan, Heang-Ping; Zhou, Chuan; Wei, Jun; Chughtai, Aamer; Kuriakose, Jean; Agarwal, Prachi; Kazerooni, Ella

    2016-01-01

    The detection of stenotic plaques strongly depends on the quality of the coronary arterial tree imaged with coronary CT angiography (cCTA). However, it is time consuming for the radiologist to select the best-quality vessels from the multiple-phase cCTA for interpretation in clinical practice. We are developing an automated method for selection of the best-quality vessels from coronary arterial trees in multiple-phase cCTA to facilitate radiologist's reading or computerized analysis. Our automated method consists of vessel segmentation, vessel registration, corresponding vessel branch matching, vessel quality measure (VQM) estimation, and automatic selection of best branches based on VQM. For every branch, the VQM was calculated as the average radial gradient. An observer preference study was conducted to visually compare the quality of the selected vessels. 167 corresponding branch pairs were evaluated by two radiologists. The agreement between the first radiologist and the automated selection was 76% with kappa of 0.49. The agreement between the second radiologist and the automated selection was also 76% with kappa of 0.45. The agreement between the two radiologists was 81% with kappa of 0.57. The observer preference study demonstrated the feasibility of the proposed automated method for the selection of the best-quality vessels from multiple cCTA phases.

  17. ART 3.5D: an algorithm to label arteries and veins from three-dimensional angiography.

    PubMed

    Barra, Beatrice; De Momi, Elena; Ferrigno, Giancarlo; Pero, Guglielmo; Cardinale, Francesco; Baselli, Giuseppe

    2016-10-01

    Preoperative three-dimensional (3-D) visualization of brain vasculature by digital subtraction angiography from computerized tomography (CT) in neurosurgery is gaining more and more importance, since vessels are the primary landmarks both for organs at risk and for navigation. Surgical embolization of cerebral aneurysms and arteriovenous malformations, epilepsy surgery, and stereoelectroencephalography are a few examples. Contrast-enhanced cone-beam computed tomography (CE-CBCT) represents a powerful facility, since it is capable of acquiring images in the operation room, shortly before surgery. However, standard 3-D reconstructions do not provide a direct distinction between arteries and veins, which is of utmost importance and is left to the surgeon's inference so far. Pioneering attempts by true four-dimensional (4-D) CT perfusion scans were already described, though at the expense of longer acquisition protocols, higher dosages, and sensible resolution losses. Hence, space is open to approaches attempting to recover the contrast dynamics from standard CE-CBCT, on the basis of anomalies overlooked in the standard 3-D approach. This paper aims at presenting algebraic reconstruction technique (ART) 3.5D, a method that overcomes the clinical limitations of 4-D CT, from standard 3-D CE-CBCT scans. The strategy works on the 3-D angiography, previously segmented in the standard way, and reprocesses the dynamics hidden in the raw data to recover an approximate dynamics in each segmented voxel. Next, a classification algorithm labels the angiographic voxels and artery or vein. Numerical simulations were performed on a digital phantom of a simplified 3-D vasculature with contrast transit. CE-CBCT projections were simulated and used for ART 3.5D testing. We achieved up to 90% classification accuracy in simulations, proving the feasibility of the presented approach for dynamic information recovery for arteries and veins segmentation.

  18. Is chest x-ray an adequate screening tool for the diagnosis of blunt thoracic aortic injury?

    PubMed

    Ekeh, Akpofure Peter; Peterson, Wylan; Woods, Randy J; Walusimbi, Mbaga; Nwuneli, Nancy; Saxe, Jonathan M; McCarthy, Mary C

    2008-11-01

    Blunt thoracic aortic injuries (BTAI) have a high mortality rate. For survivors, chest X-ray (CXR) findings are used to determine the need for further diagnostic testing with chest computerized tomography with angiography (CTA) or conventional angiography. We set to determine the adequacy of utilizing CXR alone as a screening tool for BTAI. All patients diagnosed with BTAI at a level I trauma-center during a 7-year-period were identified. CXRs of these patients and those of a control group of blunt trauma patients with an injury severity score >15 were reviewed by four trauma surgeons blinded to the diagnosis. Based on each CXR viewed, the surgeons decided if they would have proceeded to chest CTA, angiography, or required no further studies to rule out BTAI. In the 7-year-period, 83 patients had BTAI. CXRs were available in 45 patients. The four surgeons viewed 96 CXRs including those of 51 controls. Based on the CXR appearance in patients with BTAI, the surgeons chose to proceed to chest CTA in 38 patients (84.4%), conventional aortography in two patients (4.4%), and no further testing in five patients (11.2%). A widened mediastinum (75%) and loss of the aorto-pulmonary window (40%) were the most frequent CXR abnormalities. Patients with BTAI were more likely to have an abnormal CXR-40 of 45 (88.8%) patients when compared with the controls-25 of 51 (49%)patients-p < 0.001. Although CXR is a sensitive screening modality, it failed to identify the possibility of BTAI in 11% of patients. The liberal use of chest CTA after high speed motor vehicle crashes is recommended to minimize the incidence of missed BTAI.

  19. Accuracy of Computed Tomographic Perfusion in Diagnosis of Brain Death: A Prospective Cohort Study.

    PubMed

    Sawicki, Marcin; Sołek-Pastuszka, Joanna; Chamier-Ciemińska, Katarzyna; Walecka, Anna; Bohatyrewicz, Romuald

    2018-05-04

    BACKGROUND This study was designed to determine diagnostic accuracy of computed tomographic perfusion (CTP) compared to computed tomographic angiography (CTA) for the diagnosis of brain death (BD). MATERIAL AND METHODS Whole-brain CTP was performed in patients diagnosed with BD and in patients with devastating brain injury with preserved brainstem reflexes. CTA was derived from CTP datasets. Cerebral blood flow (CBF) and volume (CBV) were calculated in all brain regions. CTP findings were interpreted as confirming diagnosis of BD (positive) when CBF and CBV in all ROIs were below 10 mL/100 g/min and 1.0 mL/100 g, respectively. CTA findings were interpreted using a 4-point system. RESULTS Fifty brain-dead patients and 5 controls were included. In brain-dead patients, CTP results revealed CBF 0.00-9.98 mL/100 g/min and CBV 0.00-0.99 mL/100 g, and were thus interpreted as positive in all patients. CTA results suggested 7 negative cases, providing 86% sensitivity. In the non-brain-dead group, CTP results revealed CBF 2.37-37.59 mL/100 g/min and CBV 0.73-2.34 mL/100 g. The difference between values of CBF and CBV in the brain-dead and non-brain-dead groups was statistically significant (p=0.002 for CBF and p=0.001 for CBV). CTP findings in all non-brain-dead patients were interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTP in the diagnosis of BD. In all non-brain-dead patients, CTA revealed preserved intracranial filling and was interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTA in diagnosis of BD. CONCLUSIONS Whole-brain CTP seems to be a highly sensitive and specific method in diagnosis of BD.

  20. Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bapst, Blanche, E-mail: blanchebapst@hotmail.com; Lagadec, Matthieu, E-mail: matthieu.lagadec@bjn.aphp.fr; Breguet, Romain, E-mail: romain.breguet@hcuge.ch

    Cone beam computed tomography (CBCT) is an imaging modality that provides computed tomographic images using a rotational C-arm equipped with a flat panel detector as part of the Angiography suite. The aim of this technique is to provide additional information to conventional 2D imaging to improve the performance of interventional liver oncology procedures (intraarterial treatments such as chemoembolization or selective internal radiation therapy, and percutaneous tumor ablation). CBCT provides accurate tumor detection and targeting, periprocedural guidance, and post-procedural evaluation of treatment success. This technique can be performed during intraarterial or intravenous contrast agent administration with various acquisition protocols to highlightmore » liver tumors, liver vessels, or the liver parenchyma. The purpose of this review is to present an extensive overview of published data on CBCT in interventional oncology of the liver, for both percutaneous ablation and intraarterial procedures.« less

  1. Endovascular repair of a traumatic arteriovenous fistula 34 years after the injury: report of a case.

    PubMed

    Baril, Donald T; Denoya, Paula I; Ellozy, Sharif H; Carroccio, Alfio; Marin, Michael L

    2007-01-01

    Penetrating extremity injuries can result in the development of arteriovenous fistulas (AVFs), whereby normal blood flow through the capillary bed is bypassed. Late complications of untreated AVFs include proximal arterial dilatation, venous congestion, congestive heart failure, and distal ischemia. We report the case of a 57-year-old man who was referred to us for treatment of a traumatic AVF with multiple sequelae, 34 years after he sustained a shrapnel injury to his right lower leg. We performed successful endovascular repair of this AVF with the patient under spinal anesthesia. Computed tomographic angiography (CTA) done 1 month and 6 months later confirmed AVF exclusion. Patients may present with sequelae of traumatic AVFs many years after their initial injury. Endovascular repair of AVFs offers several advantages over conventional repair and can be performed successfully even in the presence of complex anatomic abnormalities.

  2. Performance evaluation of an automatic segmentation method of cerebral arteries in MRA images by use of a large image database

    NASA Astrophysics Data System (ADS)

    Uchiyama, Yoshikazu; Asano, Tatsunori; Hara, Takeshi; Fujita, Hiroshi; Kinosada, Yasutomi; Asano, Takahiko; Kato, Hiroki; Kanematsu, Masayuki; Hoshi, Hiroaki; Iwama, Toru

    2009-02-01

    The detection of cerebrovascular diseases such as unruptured aneurysm, stenosis, and occlusion is a major application of magnetic resonance angiography (MRA). However, their accurate detection is often difficult for radiologists. Therefore, several computer-aided diagnosis (CAD) schemes have been developed in order to assist radiologists with image interpretation. The purpose of this study was to develop a computerized method for segmenting cerebral arteries, which is an essential component of CAD schemes. For the segmentation of vessel regions, we first used a gray level transformation to calibrate voxel values. To adjust for variations in the positioning of patients, registration was subsequently employed to maximize the overlapping of the vessel regions in the target image and reference image. The vessel regions were then segmented from the background using gray-level thresholding and region growing techniques. Finally, rule-based schemes with features such as size, shape, and anatomical location were employed to distinguish between vessel regions and false positives. Our method was applied to 854 clinical cases obtained from two different hospitals. The segmentation of cerebral arteries in 97.1%(829/854) of the MRA studies was attained as an acceptable result. Therefore, our computerized method would be useful in CAD schemes for the detection of cerebrovascular diseases in MRA images.

  3. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).

    PubMed

    Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R

    2005-08-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.

  4. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)

    PubMed Central

    Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.

    2005-01-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670

  5. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data

    PubMed Central

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-01-01

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone. PMID:26266764

  6. A rare case of ethambutol induced pulmonary eosinophilia

    PubMed Central

    Saha, Kaushik; Bandyopadhyay, Ankan; Sengupta, Amitabha; Jash, Debraj

    2013-01-01

    Antitubercular drug (ATD) induced eosinophilic lung disease is a rare phenomenon. It usually occurs due to isoniazid and para amino salicylic acid. A 34-year-male of sputum positive pulmonary tuberculosis, on antitubercular drugs (rifampicin, isoniazid, ethambutol, and pyrazinamide) for last 3 weeks, presented with generalized arthralgia and maculopapular rash for last 2 weeks and shortness of breath for last 1 week. Chest X-ray and High resolution computerized tomographic scan thorax showed bilateral peripheral airspace opacification. Bronchoalveolar lavage revealed 51% eosinophils of total cellularity (1200/cmm) confirming the diagnosis of pulmonary eosinophilia. ATD was stopped for 2 weeks and then reintroduced one by one. Patient again developed similar kind of symptoms with reintroduction of ethambutol. According to criteria for drug induced pulmonary eosinophilia, he was diagnosed as a case of ethambutol induced pulmonary eosinophilia. PMID:24250213

  7. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data.

    PubMed

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-08-12

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone.

  8. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography: The WIFI II Study (Wire-Free Functional Imaging II).

    PubMed

    Westra, Jelmer; Tu, Shengxian; Winther, Simon; Nissen, Louise; Vestergaard, Mai-Britt; Andersen, Birgitte Krogsgaard; Holck, Emil Nielsen; Fox Maule, Camilla; Johansen, Jane Kirk; Andreasen, Lene Nyhus; Simonsen, Jo Krogsgaard; Zhang, Yimin; Kristensen, Steen Dalby; Maeng, Michael; Kaltoft, Anne; Terkelsen, Christian Juhl; Krusell, Lars Romer; Jakobsen, Lars; Reiber, Johan H C; Lassen, Jens Flensted; Bøttcher, Morten; Bøtker, Hans Erik; Christiansen, Evald Høj; Holm, Niels Ramsing

    2018-03-01

    Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717. © 2018 The Authors.

  9. Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries.

    PubMed

    Nael, Kambiz; Khan, Rihan; Choudhary, Gagandeep; Meshksar, Arash; Villablanca, Pablo; Tay, Jennifer; Drake, Kendra; Coull, Bruce M; Kidwell, Chelsea S

    2014-07-01

    If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scale ≥3, and absence of MRI contraindications. A combination of echo-planar imaging (EPI) and a parallel acquisition technique were used on a 3T magnetic resonance (MR) scanner to accelerate the acquisition time. Image analysis was performed independently by 2 neuroradiologists. A total of 62 patients met inclusion criteria. A repeat MRI scan was performed in 22 patients resulting in a total of 84 MRIs available for analysis. Diagnostic image quality was achieved in 100% of diffusion-weighted imaging, 100% EPI-fluid attenuation inversion recovery imaging, 98% EPI-gradient recalled echo, 90% neck MR angiography and 96% of brain MR angiography, and 94% of dynamic susceptibility contrast perfusion scans with interobserver agreements (k) ranging from 0.64 to 0.84. Fifty-nine patients (95%) had acute infarction. There was good interobserver agreement for EPI-fluid attenuation inversion recovery imaging findings (k=0.78; 95% confidence interval, 0.66-0.87) and for detection of mismatch classification using dynamic susceptibility contrast-Tmax (k=0.92; 95% confidence interval, 0.87-0.94). Thirteen acute intracranial hemorrhages were detected on EPI-gradient recalled echo by both observers. A total of 68 and 72 segmental arterial stenoses were detected on contrast-enhanced MR angiography of the neck and brain with k=0.93, 95% confidence interval, 0.84 to 0.96 and 0.87, 95% confidence interval, 0.80 to 0.90, respectively. A 6-minute multimodal MR protocol with good diagnostic quality is feasible for the evaluation of patients with acute ischemic stroke and can result in significant reduction in scan time rivaling that of the multimodal computed tomographic protocol. © 2014 American Heart Association, Inc.

  10. Diagnostic performance of computed tomography coronary angiography (from the Prospective National Multicenter Multivendor EVASCAN Study).

    PubMed

    Gueret, Pascal; Deux, Jean-François; Bonello, Laurent; Sarran, Anthony; Tron, Christophe; Christiaens, Luc; Dacher, Jean-Nicolas; Bertrand, David; Leborgne, Laurent; Renard, Cedric; Caussin, Christophe; Cluzel, Philippe; Helft, Gerard; Crochet, Dominique; Vernhet-Kovacsik, Hélène; Chabbert, Valérie; Ferrari, Emile; Gilard, Martine; Willoteaux, Serge; Furber, Alain; Barone-Rochette, Gilles; Jankowski, Adrien; Douek, Philippe; Mousseaux, Elie; Sirol, Marc; Niarra, Ralph; Chatellier, Gilles; Laissy, Jean-Pierre

    2013-02-15

    Computed tomographic coronary angiography (CTCA) has been proposed as a noninvasive test for significant coronary artery disease (CAD), but only limited data are available from prospective multicenter trials. The goal of this study was to establish the diagnostic accuracy of CTCA compared to coronary angiography (CA) in a large population of symptomatic patients with clinical indications for coronary imaging. This national, multicenter study was designed to prospectively evaluate stable patients able to undergo CTCA followed by conventional CA. Data from CTCA and CA were analyzed in a blinded fashion at central core laboratories. The main outcome was the evaluation of patient-, vessel-, and segment-based diagnostic performance of CTCA to detect or rule out significant CAD (≥50% luminal diameter reduction). Of 757 patients enrolled, 746 (mean age 61 ± 12 years, 71% men) were analyzed. They underwent CTCA followed by CA 1.7 ± 0.8 days later using a 64-detector scanner. The prevalence of significant CAD in native coronary vessels by CA was 54%. The rate of nonassessable segments by CTCA was 6%. In a patient-based analysis, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of CTCA were 91%, 50%, 68%, 83%, 1.82, and 0.18, respectively. The strongest predictors of false-negative results on CTCA were high estimated pretest probability of CAD (odds ratio [OR] 1.97, p <0.001), male gender (OR 1.5, p <0.002), diabetes (OR 1.5, p <0.0001), and age (OR 1.2, p <0.0001). In conclusion, in this large multicenter study, CTCA identified significant CAD with high sensitivity. However, in routine clinical practice, each patient should be individually evaluated, and the pretest probability of obstructive CAD should be taken into account when deciding which method, CTCA or CA, to use to diagnose its presence and severity. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Spontaneous coronary artery dissection: association with predisposing arteriopathies and precipitating stressors and cardiovascular outcomes.

    PubMed

    Saw, Jacqueline; Aymong, Eve; Sedlak, Tara; Buller, Christopher E; Starovoytov, Andrew; Ricci, Donald; Robinson, Simon; Vuurmans, Tycho; Gao, Min; Humphries, Karin; Mancini, G B John

    2014-10-01

    Nonatherosclerotic spontaneous coronary artery dissection (NA-SCAD) is underdiagnosed and an important cause of myocardial infarction in young women. The frequency of predisposing and precipitating conditions and cardiovascular outcomes remains poorly described. Patients with NA-SCAD prospectively evaluated (retrospectively or prospectively identified) at Vancouver General Hospital were included. Angiographic SCAD diagnosis was confirmed by 2 experienced interventional cardiologists and categorized as type 1 (multiple lumen), 2 (diffuse stenosis), or 3 (mimic atherosclerosis). Fibromuscular dysplasia screening of renal, iliac, and cerebrovascular arteries were performed with angiography or computed tomographic angiography/MR angiography. Baseline, predisposing and precipitating conditions, angiographic, revascularization, in-hospital, and long-term events were recorded. We prospectively evaluated 168 patients with NA-SCAD. Average age was 52.1±9.2 years, 92.3% were women (62.3% postmenopausal). All presented with myocardial infarction. ECG showed ST-segment elevation in 26.1%, and 3.6% had ventricular tachycardia/ventricular fibrillation arrest. Fibromuscular dysplasia was diagnosed in 72.0%. Precipitating emotional or physical stress was reported in 56.5%. Majority had type 2 angiographic SCAD (67.0%), only 29.1% had type 1, and 3.9% had type 3. The majority (134/168) were initially treated conservatively. Overall, 6 of 168 patients had coronary artery bypass surgery and 33 of 168 had percutaneous coronary intervention in-hospital. Of those treated conservatively (n=134), 3 required revascularization for SCAD extension, and all 79 who had repeat angiogram ≥26 days later had spontaneous healing. Two-year major adverse cardiac events were 16.9% (retrospectively identified group) and 10.4% (prospectively identified group). Recurrent SCAD occurred in 13.1%. Majority of patients with NA-SCAD had fibromuscular dysplasia and type 2 angiographic SCAD. Conservative therapy was associated with spontaneous healing. NA-SCAD survivors are at risk for recurrent cardiovascular events, including recurrent SCAD. © 2014 American Heart Association, Inc.

  12. En face choroidal vascular feature imaging in acute and chronic central serous chorioretinopathy using swept source optical coherence tomography.

    PubMed

    Lee, Won June; Lee, Jung Wook; Park, Seung Hun; Lee, Byung Ro

    2017-05-01

    To evaluate the variable depth tomographic features of choroidal vasculature in acute and chronic central serous chorioretinopathy (CSC) using swept source optical coherence tomography (SS-OCT) en face imaging. We retrospectively reviewed the en face SS-OCT images of 29 patients that presented with acute (12 eyes) or chronic (17 eyes) CSC. All of the patient eyes underwent 6×6 macular scans with SS-OCT (DRI OCT-1, Topcon, Tokyo, Japan), fluorescein angiography and indocyanine green angiography. The en face image was used to investigate the choroidal vasculature of each layer. Moreover, we determined that some parts corresponded to choriocapillaris and Sattler's layer attenuation, whereas choroidal vessel dilatation was associated with Haller's layer. At Haller's layer level, choroidal vessel dilatation was observed in 11 of 12 acute CSC (91.7%) and 15 of 17 chronic CSC (88.2%). In acute CSC, choroidal vessel dilatation was divided into focal (9/11; 81.8%) and diffuse (2/11; 18.2%) patterns. The chronic CSC cases demonstrated different patterns of choroidal vessel dilatation: focal (5/15; 33.3%) and diffuse (10/15; 66.6%). Ten of the acute CSC eyes (83.3%) and 14 of the chronic CSC eyes (82.4%) were found to have obscured choriocapillaris and Sattler's layers on en face imaging. En face imaging of SS-OCT is useful when combined with angiography in CSC for evaluating choroidal vessel dilatation at Haller's layer and to identify obscured upper layers. We identified different choroidal vessel dilatation patterns between acute and chronic CSC. These findings might be useful for pathophysiological understanding of CSC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    PubMed

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (P<0.001). The clinical outcome measured by the modified Rankin Scale was significantly worse in patients with spot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  14. [Early macular edema after phacoemulsification and suspected overdose of cefuroxime: report of six cases].

    PubMed

    Le Dû, B; Pierre-Kahn, V

    2014-03-01

    Antibiotic prophylaxis by intracameral cefuroxime injection, 1mg/0.1 mL after cataract surgery is increasing in popularity. Several cases of early postoperative macular edema have recently been reported after cefuroxime injection, most of them due to accidental cefuroxime overdose. We report six additional cases of macular involvement after cataract surgery, with intracameral cefuroxime injection imputed to cause retinal toxicity. Formal proof of cefuroxime overdose has never been possible, due to rapid wash-out in a few hours and the diagnosis of the macular edema the day after surgery or within a few days. Thus, this strong suspicion is based on clinical, pharmacokinetic, tomographic and retinographic criteria. In our series of six cases, the first four patients involved the same surgeon in the same hospital, and two of them on the same day. For the sixth case, the diagnosis was made retrospectively and based on history and medium-term tomographic characteristics. All the patients underwent optical coherence tomography (OCT) relatively early. As early as day one after surgery, there is macular edema predominantly in the outer retinal layers associated with serous retinal detachment, similar to the cases described in the literature. In the late stage, three patients had functional impairment related to photoreceptor damage on OCT. Three cases are described with additional retinal imaging (angiography, autofluorescence) to better characterize this macular toxicity associated with cefuroxime. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.

    PubMed

    Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli

    2012-08-15

    This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p <0.001). On receiver operating characteristic analysis, an EAT value ≥ 2.4 mm predicted the presence of significant (>50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p <0.05) and between patients with a calcium score >400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Spectral-Domain Optical Coherence Tomographic Angiography in Children With Amblyopia.

    PubMed

    Lonngi, Marcela; Velez, Federico G; Tsui, Irena; Davila, Juan Pablo; Rahimi, Mansour; Chan, Clarissa; Sarraf, David; Demer, Joseph L; Pineles, Stacy L

    2017-10-01

    Amblyopia is the most common cause of visual impairment in childhood, with a prevalence of 1% to 4% in children in the United States. To date, no studies using noninvasive optical coherence tomographic angiography (OCTA) have measured blood flow in the retinal capillary layers in children with amblyopia. To evaluate the retinal and microvascular features using OCTA in children (<18 years) with amblyopia. This observational case-control study enrolled patients from September 1, 2016, through May 31, 2017, and was conducted from September 1, 2016, through June 30, 2017, at the Stein Eye Institute at UCLA (University of California, Los Angeles). Participants included 59 children (<18 years) with amblyopia and without amblyopia examined at a pediatric ophthalmology clinic or referred to the clinic by coinvestigators. All patients underwent comprehensive ophthalmological examination, including visual acuity, refraction, and ocular motility tests; anterior and posterior segment examination; and OCTA. Reduced superficial and deep retinal capillary vessel density on OCTA. Of the 63 eyes evaluated, 13 (21%) were amblyopic and 50 (79%) were control eyes. Of the 59 patients, the mean (SD) age of patients with amblyopia was 8.0 (4.0) years and 10.3 (3.3) years for the controls; 33 patients (56%) were female; and 5 of 13 (39%) and 27 of 46 (54%) patients in the amblyopic and control groups, respectively, were identified as white. The macular vessel density of the superficial capillary plexus was lower in the amblyopic group than in the control group in both 3 × 3-mm and 6 × 6-mm scans. After adjusting for age and refractive error, the mean (SD) difference in the superficial capillary plexus in the 6 × 6-mm scan was statistically significant (49.3% [4.1] vs 51.2% [2.9]; P = .02). Macular vessel density of the deep capillary plexus in the 6 × 6-mm scans was also considerably different between groups: mean (SD) vessel density of the deep retinal capillary plexus was 54.4% (4.7%) in the amblyopia group and 60.1% (3.3%) in the control group, with a difference of 5.7% (95% CI, 3.4%-8.1%; P = .002). The study found that OCTA reveals subnormal superficial and deep retinal capillary density in the macula of patients with amblyopia. Further studies are needed to determine the clinical relevance of this finding.

  17. Influence of contrast media viscosity and temperature on injection pressure in computed tomographic angiography: a phantom study.

    PubMed

    Kok, Madeleine; Mihl, Casper; Mingels, Alma A; Kietselaer, Bas L; Mühlenbruch, Georg; Seehofnerova, Anna; Wildberger, Joachim E; Das, Marco

    2014-04-01

    Iodinated contrast media (CM) in computed tomographic angiography is characterized by its concentration and, consecutively, by its viscosity. Viscosity itself is directly influenced by temperature, which will furthermore affect injection pressure. Therefore, the purposes of this study were to systematically evaluate the viscosity of different CM at different temperatures and to assess their impact on injection pressure in a circulation phantom. Initially, viscosity of different contrast media concentrations (240, 300, 370, and 400 mgI/mL) was measured at different temperatures (20°C-40°C) with a commercially available viscosimeter. In the next step, a circulation phantom with physical conditions was used. Contrast media were prepared at different temperatures (20°C, 30°C, 37°C) and injected through a standard 18-gauge needle. All other relevant parameters were kept constant (iodine delivery rate, 1.9 g I/s; total amount of iodine, 15 g I). Peak flow rate (in milliliter per second) and injection pressure (psi) were monitored. Differences in significance were tested using the Kruskal-Wallis test (Statistical Package for the Social Sciences). Viscosities for iodinated CM of 240, 300, 370, and 400 mg I/mL at 20°C were 5.1, 9.1, 21.2, and 28.8 mPa.s, respectively, whereas, at 40°C, these were substantially lower (2.8, 4.4, 8.7, and 11.2 mPa.s). In the circulation phantom, mean (SD) peak pressures for CM of 240 mg I/mL at 20°C, 30°C, and 37°C were 107 (1.5), 95 (0.6), and 92 (2.1) psi; for CM of 300 mg I/mL, 119 (1.5), 104 (0.6), and 100 (3.6) psi; for CM of 370 mg I/mL, 150 (0.6), 133 (4.4), and 120 (3.5) psi; and for CM of 400 mg I/mL, 169 (1.0), 140 (2.1), and 135 (2.9) psi, respectively, with all P values less than 0.05. Low concentration, low viscosity, and high temperatures of CM are beneficial in terms of injection pressure. This should also be considered for individually tailored contrast protocols in daily routine scanning.

  18. Use of a hybrid iterative reconstruction technique to reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography.

    PubMed

    Kligerman, Seth; Mehta, Dhruv; Farnadesh, Mahmmoudreza; Jeudy, Jean; Olsen, Kathryn; White, Charles

    2013-01-01

    To determine whether an iterative reconstruction (IR) technique (iDose, Philips Healthcare) can reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography (CTPA). The study was Health Insurance Portability and Accountability Act compliant and approved by our institutional review board. A total of 33 obese patients (average body mass index: 42.7) underwent CTPA studies following standard departmental protocols. The data were reconstructed with filtered back projection (FBP) and 3 iDose strengths (iDoseL1, iDoseL3, and iDoseL5) for a total of 132 studies. FBP data were collected from 33 controls (average body mass index: 22) undergoing CTPA. Regions of interest were drawn at 6 identical levels in the pulmonary artery (PA), from the main PA to a subsegmental branch, in both the control group and study groups using each algorithm. Noise and attenuation were measured at all PA levels. Three thoracic radiologists graded each study on a scale of 1 (very poor) to 5 (ideal) by 4 categories: image quality, noise, PA enhancement, and "plastic" appearance. Statistical analysis was performed using an unpaired t test, 1-way analysis of variance, and linear weighted κ. Compared with the control group, there was significantly higher noise with FBP, iDoseL1, and iDoseL3 algorithms (P<0.001) in the study group. There was no significant difference between the noise in the control group and iDoseL5 algorithm in the study group. Analysis within the study group showed a significant and progressive decrease in noise and increase in the contrast-to-noise ratio as the level of IR was increased (P<0.001). Compared with FBP, readers graded overall image quality as being higher using iDoseL1 (P=0.0018), iDoseL3 (P<0.001), and iDoseL5 (P<0.001). Compared with FBP, there was subjective improvement in image noise and PA enhancement with increasing levels of iDose. The use of an IR technique leads to qualitative and quantitative improvements in image noise and image quality in obese patients undergoing CTPA.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zanchetta, Mario, E-mail: emodinacit@ulss15.pd.it; Rigatelli, Gianluca; Pedon, Luigi

    To assess the accuracy and efficacy of intravascular ultrasound guidance obtained by an intracardiac ultrasound probe during complex aortic endografting. Between November 1999 and July 2002, 19 patients (5 female, 14 male; mean age 73.5 {+-} 2.1 years) underwent endovascular repair of thoracic (n = 10), complex abdominal (n = 6) and concomitant thoraco-abdominal (n = 3) aortic aneurysm. The most suitable size and configuration of the stent-graft were chosen on the basis of preoperative computed tomographic angiography (CTA) or magnetic resonance angiography (MRA). Intraoperative intravascular ultrasound imaging was obtained using a 9 Fr, 9 MHz intracardiac echocardiography (ICE) probe,more » 110 cm in length, inserted through a 10 Fr precurved long sheath. The endografts were deployed as planned by CTA or MRA. Before stent-graft deployment, the ICE probe allowed us to view the posterior aortic arch and descending thoraco-abdominal aorta without position-related artifacts, and to identify both sites of stent-graft positioning. After stent-graft deployment, the ICE probe allowed us to detect the need for additional modular components to internally reline the aorta in 11 patients, and to discover 2 incomplete graft expansions subsequently treated with adjunctive balloon angioplasty. In 1 patient, the ICE probe supported the decision that the patient was ineligible for the endovascular exclusion procedure. The ICE probe provides accurate information on the anatomy of the posterior aortic arch and thoracic and abdominal aortic aneurysms and a rapid identification of attachment sites and stent-graft pathology, allowing refinement and improvement of the endovascular strategy.« less

  20. Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection

    NASA Astrophysics Data System (ADS)

    Li, Yinsheng; Garrett, John W.; Li, Ke; Wu, Yijing; Johnson, Kevin; Schafer, Sebastian; Strother, Charles; Chen, Guang-Hong

    2018-04-01

    Time-resolved C-arm cone-beam CT (CBCT) angiography (TR-CBCTA) images can be generated from a series of CBCT acquisitions that satisfy data sufficiency condition in analytical image reconstruction theory. In this work, a new technique was developed to generate TR-CBCTA images from a single short-scan CBCT data acquisition with contrast media injection. The reconstruction technique enabling this application is a previously developed image reconstruction technique, synchronized multi-artifact reduction with tomographic reconstruction (SMART-RECON). In this new application, the acquired short-scan CBCT projection data were sorted into a union of several sub-sectors of view angles and each sub-sector of view angles corresponds to an individual image volume to be reconstructed. The SMART-RECON method was then used to jointly reconstruct all of these individual image volumes under two constraints: (1) each individual image volume is maximally consistent with the measured cone-beam projection data within the corresponding view angle sector and (2) the nuclear norm of the image matrix is minimized. The difference between these reconstructed individual image volumes is used to generated the desired subtracted angiograms. To validate the technique, numerical simulation data generated from a fractal tree angiogram phantom were used to quantitatively study the accuracy of the proposed method and retrospective in vivo human subject studies were used to demonstrate the feasibility of generating TR-CBCTA in clinical practice.

  1. Diagnosis and surgical approach of popliteal artery entrapment syndrome: a retrospective study.

    PubMed

    Gourgiotis, Stavros; Aggelakas, John; Salemis, Nikolaos; Elias, Charalabos; Georgiou, Charalabos

    2008-01-01

    Popliteal artery entrapment syndrome (PAES) is a rare but potentially limb threatening peripheral vascular disease occurring predominantly in young adults. This study is a retrospective review of 49 limbs in 38 patients with PAES treated surgically over an 8-year period. From 1995 to 2002, 38 patients with a mean age of 21 years (range, 18-29 years) underwent surgery for PAES at a single institution. The patients' demographic data and clinical features are recorded. The preoperative diagnosis of PAES was made based on various combinations of investigations including positional stress test, duplex ultrasonography, computed tomography, computed tomographic angiography, and angiography. Nine, 33, and 7 patients had Delaney's type I, II, and III PAES respectively. The surgical procedures consisted of simple release of the popliteal artery in 33 limbs (67.3%), autogenous saphenous vein (ASV) patch angioplasty with or without thromboendarterectomy (TEA) in 5 limbs (10.2%) and ASV graft interposition or bypass in 11 limbs (22.5%). At a median follow up of 34 months (range, 8-42 months), there were no postoperative complications and all the patients were cured of their symptoms. PAES is an unusual but important cause of peripheral vascular insufficiency especially in young patients. Early diagnosis through a combined approach is necessary for exact diagnosis. Popliteal artery release alone or with vein bypass is the treatment of choice when intervention is indicated for good operative outcome and to prevent limb loss.

  2. Total Face, Eyelids, Ears, Scalp, and Skeletal Subunit Transplant Research Procurement: A Translational Simulation Model.

    PubMed

    Sosin, Michael; Ceradini, Daniel J; Hazen, Alexes; Sweeney, Nicole G; Brecht, Lawrence E; Levine, Jamie P; Staffenberg, David A; Saadeh, Pierre B; Bernstein, G Leslie; Rodriguez, Eduardo D

    2016-05-01

    Cadaveric face transplant models are routinely used for technical allograft design, perfusion assessment, and transplant simulation but are associated with substantial limitations. The purpose of this study was to describe the experience of implementing a translational donor research facial procurement and solid organ allograft recovery model. Institutional review board approval was obtained, and a 49-year-old, brain-dead donor was identified for facial vascularized composite allograft research procurement. The family generously consented to donation of solid organs and the total face, eyelids, ears, scalp, and skeletal subunit allograft. The successful sequence of computed tomographic scanning, fabrication and postprocessing of patient-specific cutting guides, tracheostomy placement, preoperative fluorescent angiography, silicone mask facial impression, donor facial allograft recovery, postprocurement fluorescent angiography, and successful recovery of kidneys and liver occurred without any donor instability. Preservation of the bilateral external carotid arteries, facial arteries, occipital arteries, and bilateral thyrolinguofacial and internal jugular veins provided reliable and robust perfusion to the entirety of the allograft. Total time of facial procurement was 10 hours 57 minutes. Essential to clinical face transplant outcomes is the preparedness of the institution, multidisciplinary face transplant team, organ procurement organization, and solid organ transplant colleagues. A translational facial research procurement and solid organ recovery model serves as an educational experience to modify processes and address procedural, anatomical, and logistical concerns for institutions developing a clinical face transplantation program. This methodical approach best simulates the stressors and challenges that can be expected during clinical face transplantation. Therapeutic, V.

  3. Automated estimation of image quality for coronary computed tomographic angiography using machine learning.

    PubMed

    Nakanishi, Rine; Sankaran, Sethuraman; Grady, Leo; Malpeso, Jenifer; Yousfi, Razik; Osawa, Kazuhiro; Ceponiene, Indre; Nazarat, Negin; Rahmani, Sina; Kissel, Kendall; Jayawardena, Eranthi; Dailing, Christopher; Zarins, Christopher; Koo, Bon-Kwon; Min, James K; Taylor, Charles A; Budoff, Matthew J

    2018-03-23

    Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

  4. Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anil, Gopinathan, E-mail: ivyanil10@gmail.com; Tay, Kiang-Hiong; Howe, Tse-Chiang

    2011-04-15

    This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affectedmore » in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.« less

  5. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    PubMed

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  6. Cerebrospinal fluid flow abnormalities in patients with neoplastic meningitis. An evaluation using /sup 111/In-DTPA ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grossman, S.A.; Trump, D.L.; Chen, D.C.

    1982-11-01

    Cerebrospinal fluid flow dynamics were evaluated by /sup 111/In-diethylenetriamine pentaacetic acid (/sup 111/In-DTPA) ventriculography in 27 patients with neoplastic meningitis. Nineteen patients (70 percent) had evidence of cerebrospinal fluid flow disturbances. These occurred as ventricular outlet obstructions, abnormalities of flow in the spinal canal, or flow distrubances over the cortical convexities. Tumor histology, physical examination, cerebrospinal fluid analysis, myelograms, and computerized axial tomographic scans were not sufficient to predict cerebrospinal fluid flow patterns. These data indicate that cerebrospinal fluid flow abnormalities are common in patients with neoplastic meningitis and that /sup 111/In-DTPA cerebrospinal fluid flow imaging is useful in characterizingmore » these abnormalities. This technique provides insight into the distribution of intraventricularly administered chemotherapy and may provide explanations for treatment failure and drug-induced neurotoxicity in patients with neoplastic meningitis.« less

  7. Vertical structure of medium-scale traveling ionospheric disturbances

    NASA Astrophysics Data System (ADS)

    Ssessanga, Nicholas; Kim, Yong Ha; Kim, Eunsol

    2015-11-01

    We develop an algorithm of computerized ionospheric tomography (CIT) to infer information on the vertical and horizontal structuring of electron density during nighttime medium-scale traveling ionospheric disturbances (MSTIDs). To facilitate digital CIT we have adopted total electron contents (TEC) from a dense Global Positioning System (GPS) receiver network, GEONET, which contains more than 1000 receivers. A multiplicative algebraic reconstruction technique was utilized with a calibrated IRI-2012 model as an initial solution. The reconstructed F2 peak layer varied in altitude with average peak-to-peak amplitude of ~52 km. In addition, the F2 peak layer anticorrelated with TEC variations. This feature supports a theory in which nighttime MSTID is composed of oscillating electric fields due to conductivity variations. Moreover, reconstructed TEC variations over two stations were reasonably close to variations directly derived from the measured TEC data set. Our tomographic analysis may thus help understand three-dimensional structure of MSTIDs in a quantitative way.

  8. Measurement of absolute lung volumes by imaging techniques.

    PubMed

    Clausen, J

    1997-10-01

    In this paper, the techniques available for estimating total lung capacities from standard chest radiographs in children and infants as well as adults are reviewed. These techniques include manual measurements using ellipsoid and planimetry techniques as well as computerized systems. Techniques are also available for making radiographic lung volume measurements from portable chest radiographs. There are inadequate data in the literature to support recommending one specific technique over another. Though measurements of lung volumes by radiographic, plethysmographic, gas dilution or washout techniques result in remarkably similar mean results when groups of normal subjects are tested, in patients with disease, the results of these different basic measurement techniques can differ significantly. Computed tomographic and magnetic resonance techniques can also be used to measure absolute lung volumes and offer the theoretical advantages that the results in individual subjects are less affected by variances of thoracic shape than are measurements made using conventional chest radiographs.

  9. Technical report on semiautomatic segmentation using the Adobe Photoshop.

    PubMed

    Park, Jin Seo; Chung, Min Suk; Hwang, Sung Bae; Lee, Yong Sook; Har, Dong-Hwan

    2005-12-01

    The purpose of this research is to enable users to semiautomatically segment the anatomical structures in magnetic resonance images (MRIs), computerized tomographs (CTs), and other medical images on a personal computer. The segmented images are used for making 3D images, which are helpful to medical education and research. To achieve this purpose, the following trials were performed. The entire body of a volunteer was scanned to make 557 MRIs. On Adobe Photoshop, contours of 19 anatomical structures in the MRIs were semiautomatically drawn using MAGNETIC LASSO TOOL and manually corrected using either LASSO TOOL or DIRECT SELECTION TOOL to make 557 segmented images. In a similar manner, 13 anatomical structures in 8,590 anatomical images were segmented. Proper segmentation was verified by making 3D images from the segmented images. Semiautomatic segmentation using Adobe Photoshop is expected to be widely used for segmentation of anatomical structures in various medical images.

  10. Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics.

    PubMed

    Silvestrini Biavati, A; Tecco, S; Migliorati, M; Festa, F; Panza, G; Marzo, G; Gherlone, E; Tetè, S

    2011-05-01

    To evaluate the maxilla, mandible, and cortical plates on computerized tomographic (CT) scans to achieve accurate three-dimensional bone thickness measurements. We selected the CT scans of 25 subjects (among 102), aged 18-58 years (10 men, 15 women), with nearly complete dentition. We performed interradicular and bucco-lingual (including cortical plate thickness) measurements in dental areas distal to the canines in both alveolar arches, at three levels (5, 8, and 11 mm) from the alveolar ridge. The mean thicknesses of the cortical plates in the maxilla were 1.10 mm buccally and 1.27 mm on the palatal side (p < 0.05). In the mandible, cortical plates were 2.23 mm buccally and 2.02 mm lingually. Mandibular buccal and lingual cortical plates became thicker distally in the second and third molar areas. There was considerable variation in cortical thickness (from 0.25 to 5.50 mm). Based on interradicular distances, only 13% of measured sites in the maxilla were suitable for miniscrew insertion (≥3.3 mm), but 63% of sites were suitable in the mandible. This study showed considerable individual variation in bone thickness. Our data suggested that the palatal/lingual side may provide greater primary stability for miniscrews. The palatal area, between the second upper bicuspid and the first molar, appeared to be the most suitable area for tapered 7- to 9-mm miniscrews, starting at 1.5-2 mm from the alveolar crest. © 2011 John Wiley & Sons A/S.

  11. Laterality and Left-sidedness in the Nose, Face, and Body: A New Finding.

    PubMed

    Hafezi, Farhad; Javdani, Ali; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi

    2017-12-01

    Asymmetry is a common occurrence in bilaterian animals, particularly human beings. Through examination of patients and their photographs during rhinoplasty, we noted wider left-sided nasal and facial features in most patients. This observation led us to hypothesize that this might be consistent to the whole body. We conducted a study in 3 parts to test the question above. First, we analyzed operating notes of 50 rhinoplasty patients to determine the wider side of the upper, middle, and lower thirds of the nose. Second, we analyzed the width of the face and chest wall in 31 patients to discern any correlation between facial and bodily asymmetry. Third, computerized tomographic scans of the thorax and body of 48 patients were studied to measure the width of the hemithorax and hemipelvic bone. (1) Upper vault width was wider on left side (78%). Left middle vault width was wider (88%). The lower lateral cartilage, lateral crura convexity was more prominent on left side (48%), and a wider scroll area was found and trimmed in 21 (left) and 0 (right) cases. The alar base was wider on left side (56%). (2) In the body and face analysis, 64.5% had a wider left-sided face and body. (3) In the computed tomographic scan analysis, same-sided thorax and pelvis asymmetry was seen (85.35%), 33 and 7 of which were left- and right-sided, respectively. We observed generalized asymmetry of the face and body with left-sided predominance.

  12. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant apices into augmented sinus lift occurred, whereas the bone remodelling of the coronal areas was not influenced by the events in the maxillary sinus. A diameter ranging from 4 to 5 mm might better guarantee a conservation of marginal peri-implant bone level compared with implants with smaller diameters. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Effect of Sandostatin LAR on sleep apnoea in acromegaly: correlation with computerized tomographic cephalometry and hormonal activity.

    PubMed

    Ip, M S; Tan, K C; Peh, W C; Lam, K S

    2001-10-01

    Sleep apnoea has been reported to occur in subjects with acromegaly. This study evaluates the relationship among biochemical activity, sleep apnoeic activity and upper airway anatomic profile in acromegaly, and the effect of Sandostatin LAR, a long-acting somatostatin analogue, on these parameters. Fourteen subjects with acromegaly were recruited. Subjects were assessed at baseline and those with apnoea-hypopnoea index (AHI) > or = 5 were reassessed after 6 months of treatment with Sandostatin LAR 20-30 mg IMI 4-weekly. Biochemical activity was assessed with levels of GH and IGF-1. Sleep disordered breathing was assessed with overnight polysomnography. Upper airway anatomic profile was defined with computerized tomographic cephalometry. Of 14 subjects (age 42.0 +/- 8.1 years, mean +/- SD; 11 men) at baseline, there was a positive correlation between GH and tongue length (VT; P = 0.004), and between AHI and cephalometric indices: length of soft palate (PMU; P = 0.002); mandibular plane-hyoid bone distance (MPH; P = 0.017), maximum thickness of soft palate (Max-SP; P = 0.018) and VT (P = 0.027). Eight patients had sleep disordered breathing (AHI > or = 5) which was predominantly obstructive in nature (AHI = 29.4 +/- 22.6). After treatment, there were significant improvements in hormonal profile: GH, mU/l (before, 51.5 +/- 27.8; after, 8.0 +/- 7.4; P = 0.017) and IGF-1, nmol/l (before, 95.5 +/- 23.4; after, 35.0 +/- 12.4; P = 0.012); sleep-disordered breathing: AHI (before, 29.4 +/- 22.6; after, 13.4 +/- 11.12; P = 0.025), snoring episodes (before, 486 +/- 240; after, 165 +/- 170; P = 0.05); cephalometric indices, mm: MPH (before, 18.8 +/- 12.1; after, 14.8 +/- 8.4; P = 0.018), VT (before, 72.3 +/- 4.4; after, 69.7 +/- 4.3; P = 0.05). There was a positive correlation between the reduction in GH and AHI (r = 0.738, P = 0.037). The findings demonstrated that there was correlation between sleep apnoea severity and soft tissue overgrowth at the upper airway region in acromegaly. They also suggest that Sandostatin LAR improved obstructive sleep apnoea in acromegaly, and the effect might be partly mediated via a reduction in upper airway soft tissue, in particular that of the tongue, concomitant with a reduction in GH levels.

  14. Three-dimensional display of cortical anatomy and vasculature: MR angiography versus multimodality integration

    NASA Astrophysics Data System (ADS)

    Henri, Christopher J.; Pike, Gordon; Collins, D. Louis; Peters, Terence M.

    1990-07-01

    We present two methods for acquiring and viewing integrated 3-D images of cerebral vasculature and cortical anatomy. The aim of each technique is to provide the neurosurgeon or radiologist with a 3-D image containing information which cannot ordinarily be obtained from a single imaging modality. The first approach employs recent developments in MR which is now capable of imaging flowing blood as well as static tissue. Here, true 3-D data are acquired and displayed using volume or surface rendering techniques. The second approach is based on the integration of x-ray projection angiograms and tomographic image data, allowing a composite image of anatomy and vasculature to be viewed in 3-D. This is accomplished by superimposing an angiographic stereo-pair onto volume rendered images of either CT or MR data created from matched viewing geometries. The two approaches are outlined and compared. Results are presented for each technique and potential clinical applications discussed.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Köklü, Erkan, E-mail: drerkankoklu@gmail.com; Arslan, Şakir; Yüksel, İsa Öner

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after themore » procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication.« less

  16. Iatrogenic arteriovenous fistula of the superficial temporal artery after reduction malarplasty.

    PubMed

    Kim, Jun Hyuk; Yoon, Seok Mann; Choi, Hwan Jun

    2015-01-01

    A 34-year-old woman who had a history of undergoing reduction malarplasty at a local clinic about 1 year ago developed gradually increasing pulsatile tinnitus in the right preauricular area since the last 6 months. On physical examination, there were an approximately 1 × 0.5-cm nontender, soft, pulsatile mass with a palpable thrill and a continuous machinery-like buzzing sound in synchrony with the heartbeat. She had a fine scar near the mass, which was supposed to be a postoperative scar of reduction malarplasty. A three-dimensional computed tomographic angiogram revealed a direct arteriovenous fistula between the superficial temporal artery and superficial temporal vein in the right preauricular area. The arteriovenous fistula was embolized using Tornado coils. After coiling, the thrill and disturbing tinnitus disappeared immediately, and postembolization angiography confirmed obliteration of the arteriovenous shunt. This is the first case of an arteriovenous fistula of the superficial temporal artery after reduction malarplasty, and it indicates that arteriovenous fistula can occur as a delayed complication of reduction malarplasty.

  17. Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study.

    PubMed

    Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi

    2013-01-01

    Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.

  18. The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.

    PubMed

    Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J

    2018-06-23

    The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.

  19. CT features and common causes of arc of Riolan expansion: an analysis with 64-detector-row computed tomographic angiography

    PubMed Central

    Xie, Yuanliang; Jin, Chaolin; Zhang, Shutong; Wang, Xiang; Jiang, Yanping

    2015-01-01

    Objective: To study the manifestations of arc of Riolan expansion (ARE) using multi-detector computed tomography angiography (MDCTA). Materials and methods: The manifestations and clinical data of 626 consecutive mesentery CTA images were retrospectively analyzed. The 47 cases with ARE and 47 patients without expansion were involved. The average diameter of arc of Riolan was measured. Two radiologists after reaching consensus analyzed the shapes of mesenteric artery, CT findings and the occurrence and causes of ARE. Results: The mean diameter of arc of Riolan was 1.2 mm, 4.6 mm, 2.5 mm, 2.3 mm, 1.9 mm, 2.5 mm, and 2.0 mm at baseline and following obstruction of superior mesenteric artery (SMA), stenosis of SMA, obstruction of inferior mesenteric artery (IMA), stenosis of IMA, colon cancer, and active ulcerative colitis, respectively. The expansion of arc of Riolan was the most significant following obstruction of SMA. The diameters of arc of Riolan were significantly different between the upward flow group and the downward or the two-way flow groups, and between the colon tumor group and the active ulcerative colitis group. CT findings such as bowel wall thickening, contrast enhancement, intestinal obstruction, marginal artery expansion, lymph node enlargement varied and were help to identify the cause of ARE. Conclusions: ARE often suggests the occurrence of obstructed intestinal feeding artery or intestinal lesions. MDCTA can clearly display the situation of arc of Riolan and collateral circulation, and together with CT symptoms, can guide the selection of diagnosis and treatment schemes in clinic. PMID:26064208

  20. Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease.

    PubMed

    Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Shin, Seitaro; Hino, Takuya; Nagata, Hazumu; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi

    2018-05-05

    To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0-2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0-4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

  1. Anatomical variations in the origins of the celiac axis and the superior mesenteric artery: MDCT angiographic findings and their probable embryological mechanisms.

    PubMed

    Wang, Yi; Cheng, Cheng; Wang, Lu; Li, Ran; Chen, Jin-hua; Gong, Shui-gen

    2014-08-01

    To identify the spectrum and prevalence of anatomical variations in the origin of the celiac axis (CA), the superior mesenteric artery (SMA) and their major branches by using multidetector computed tomographic (MDCT) angiography. A retrospective evaluation was carried out on 1,500 abdominal MDCT angiography images. The aortic origins of the CA, the SMA and their major branch patterns were investigated. Normal aortic origins of CA and SMA were noted in 1,347 (89.8%) patients. Seven types of CA and SMA origin variants were identified in 153 (10.2%) patients. The three most common variations were hepatomesenteric trunk (67 patients, 4.47%), celiomesenteric trunk (CMT) (51 patients, 3.4%) and splenomesenteric trunk (18 patients, 1.2%). An evaluation of CMT was classified as long (34 patients, 66.7%) or short (17 patients, 33.3%) subtypes, compared with the length of the common trunk. Further CMT classification was based on the origin of the left gastric artery: subtype I, 26 patients (53.1%); subtype II, 5 patients (10.2%); subtype III, 15 patients (30.6%); subtype IV, 3 patients (6.1%). Dislocation interruption, incomplete interruption and persistence of the longitudinal anastomosis could be the embryological mechanisms of the variant origins of the CA, the SMA and their major branches. • Aortic origins of CA, SMA and their major branches were investigated. • Celiomesenteric trunk includes several different subtypes and configurations. • Probable embryological mechanisms of origin variants in these observed arteries were discussed. • Origin variants in these observed arteries have wide-ranging health implications.

  2. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    PubMed

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  3. Congenital and hereditary causes of sudden cardiac death in young adults: diagnosis, differential diagnosis, and risk stratification.

    PubMed

    Stojanovska, Jadranka; Garg, Anubhav; Patel, Smita; Melville, David M; Kazerooni, Ella A; Mueller, Gisela C

    2013-01-01

    Sudden cardiac death is defined as death from unexpected circulatory arrest-usually a result of cardiac arrhythmia-that occurs within 1 hour of the onset of symptoms. Proper and timely identification of individuals at risk for sudden cardiac death and the diagnosis of its predisposing conditions are vital. A careful history and physical examination, in addition to electrocardiography and cardiac imaging, are essential to identify conditions associated with sudden cardiac death. Among young adults (18-35 years), sudden cardiac death most commonly results from a previously undiagnosed congenital or hereditary condition, such as coronary artery anomalies and inherited cardiomyopathies (eg, hypertrophic cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy [ARVC], dilated cardiomyopathy, and noncompaction cardiomyopathy). Overall, the most common causes of sudden cardiac death in young adults are, in descending order of frequency, hypertrophic cardiomyopathy, coronary artery anomalies with an interarterial or intramural course, and ARVC. Often, sudden cardiac death is precipitated by ventricular tachycardia or fibrillation and may be prevented with an implantable cardioverter defibrillator (ICD). Risk stratification to determine the need for an ICD is challenging and involves imaging, particularly echocardiography and cardiac magnetic resonance (MR) imaging. Coronary artery anomalies, a diverse group of congenital disorders with a variable manifestation, may be depicted at coronary computed tomographic angiography or MR angiography. A thorough understanding of clinical risk stratification, imaging features, and complementary diagnostic tools for the evaluation of cardiac disorders that may lead to sudden cardiac death is essential to effectively use imaging to guide diagnosis and therapy.

  4. Absolute polycythemia in a bald eagle (Haliaeetus leucocephalus).

    PubMed

    Fernandes, Andreia F; Fenton, Heather; Martinson, Shannon; Desmarchelier, Marion; Ferrell, Shannon T

    2014-12-01

    An approximately 6-mo-old female bald eagle (Haliaeetus leucocephalus) was presented for an inability to fly and bilateral drooped wings. Pectoral muscle atrophy with a moderate polycythemia was present. Over the course of 3 wk, there were no improvements in flight capacity, although the bird gained substantial weight. Further investigation revealed a prominent cyanosis that was responsive to oxygen therapy, a chronic respiratory acidosis with hypoxia, a cardiac murmur, and a persistent polycythemia. No obvious antemortem etiology for the clinical findings was discovered on computerized tomography, angiography, or echocardiography. The bird was euthanatized as a result of the poor prognosis. Necropsy and histopathology revealed no significant cardiovascular or pulmonary pathology. No myopathy was evident on electron microscopy of formalin-fixed tissues. Based on these diagnostics, a neuromuscular disorder is suspected as the cause for the blood gas abnormalities, with a resulting polycythemia from the hypoxia.

  5. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    PubMed

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P < .01 for all). For stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P < .01 for all). There were no significant differences between stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  6. Contrast Media Administration in Coronary Computed Tomography Angiography - A Systematic Review.

    PubMed

    Mihl, Casper; Maas, Monique; Turek, Jakub; Seehofnerova, Anna; Leijenaar, Ralph T H; Kok, Madeleine; Lobbes, Marc B I; Wildberger, Joachim E; Das, Marco

    2017-04-01

    Background  Various different injection parameters influence enhancement of the coronary arteries. There is no consensus in the literature regarding the optimal contrast media (CM) injection protocol. The aim of this study is to provide an update on the effect of different CM injection parameters on the coronary attenuation in coronary computed tomographic angiography (CCTA). Method  Studies published between January 2001 and May 2014 identified by Pubmed, Embase and MEDLINE were evaluated. Using predefined inclusion criteria and a data extraction form, the content of each eligible study was assessed. Initially, 2551 potential studies were identified. After applying our criteria, 36 studies were found to be eligible. Studies were systematically assessed for quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-II checklist. Results  Extracted data proved to be heterogeneous and often incomplete. The injection protocol and outcome of the included publications were very diverse and results are difficult to compare. Based on the extracted data, it remains unclear which of the injection parameters is the most important determinant for adequate attenuation. It is likely that one parameter which combines multiple parameters (e. g. IDR) will be the most suitable determinant of coronary attenuation in CCTA protocols. Conclusion  Research should be directed towards determining the influence of different injection parameters and defining individualized optimal IDRs tailored to patient-related factors (ideally in large randomized trials). Key points   · This systematic review provides insight into decisive factors on coronary attenuation.. · Different and contradicting outcomes are reported on coronary attenuation in CCTA.. · One parameter combining multiple parameters (IDR) is likely decisive in coronary attenuation.. · Research should aim at defining individualized optimal IDRs tailored to individual factors.. · Future directions should be tailored towards the influence of different injection parameters.. Citation Format · Mihl C, Maas M, Turek J et al. Contrast Media Administration in Coronary Computed Tomography Angiography - A Systematic Review. Fortschr Röntgenstr 2017; 189: 312 - 325. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Three-Station Three-dimensional Bolus-Chase MR Angiography with Real-time Fluoroscopic Tracking

    PubMed Central

    Johnson, Casey P.; Weavers, Paul T.; Borisch, Eric A.; Grimm, Roger C.; Hulshizer, Thomas C.; LaPlante, Christine C.; Rossman, Phillip J.; Glockner, James F.; Young, Phillip M.

    2014-01-01

    Purpose To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. Materials and Methods This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30–81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47–81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. Results Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. Conclusion Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms. © RSNA, 2014 Online supplemental material is available for this article. PMID:24635676

  8. Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner

    NASA Astrophysics Data System (ADS)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.

    2006-03-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.

  9. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease.

    PubMed

    Gooley, Robert P; Cameron, James D; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T

    2015-09-01

    Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. The mean age was 59±12 years. The basal plane was eccentric (EI=0.22±0.06) while the left ventricular outflow tract was more eccentric (EI=0.32±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical reporting and for future research studies by using a standardised measurement technique. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. NECTAR—A fission neutron radiography and tomography facility

    NASA Astrophysics Data System (ADS)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  11. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    PubMed

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  12. Liquid metal angiography for mega contrast X-ray visualization of vascular network in reconstructing in-vitro organ anatomy.

    PubMed

    Wang, Qian; Yu, Yang; Pan, Keqin; Liu, Jing

    2014-07-01

    Visualization on the anatomical vessel networks plays a vital role in the physiological or pathological investigations. However, so far it still remains a big challenge to identify the fine structures of the smallest capillary vessel networks via conventional imaging ways. Here, the room temperature liquid metal angiography was proposed for the first time to generate mega contrast X-ray images for multiscale vasculature mapping. Particularly, gallium was adopted as the room temperature liquid metal contrast agent and infused into the vessels of in vitro pig hearts and kidneys. We scanned the samples under X-ray and compared the angiograms with those obtained via conventional contrast agent--the iohexol. As quantitatively demonstrated by the grayscale histograms and numerical indexes, the contrast of the vessels to the surrounding tissues in the liquid metal angiograms is orders higher than that of the iohexol enhanced images. And the angiogram has reached detailed enough width of 0.1 mm for the tiny vessels, which indicated that the capillaries can be clearly distinguished under the liquid metal enhanced images. Further, with tomography from the micro-CT, we also managed to reconstruct the 3-D structures of the kidney vessels. Tremendous clarity and efficiency of the method over existing approaches have been experimentally clarified. It was disclosed that the usually invisible capillary networks now become distinctively clear in the gallium angiograms. This basic mechanism has generalized purpose and can be extended to a wide spectrum of 3-D computational tomographic areas. It opens a new soft tool for quickly reconstructing high-resolution spatial channel networks for scientific researches as well as engineering practices where complicated and time-consuming resections are no longer a necessity.

  13. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  14. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    PubMed

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  15. Morphometric analysis of diameter and relationship of vertebral artery with respect to transverse foramen in Indian population

    PubMed Central

    Sureka, Binit; Mittal, Mahesh Kumar; Mittal, Aliza; Agarwal, Mukul Sinha Kanhaiya; Bhambri, Narendra Kumar; Thukral, Brij Bhushan

    2015-01-01

    Purpose: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA) measurements in the Indian population. Materials and Methods: A retrospective review of multi-detector CT (MDCT) cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL) and the shortest distance between the vertebral artery and the medial (M), lateral (L), anterior (A), and posterior (P) borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h) was also analyzed. Statistical Analysis: The means and their standard deviations (SD) were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. Results: The largest vertebral artery diameter (AL) was at level C7 on the right side (3.5 ± 0.8) and at the level of C5 on the left side (3.7 ± 0.4). Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P) at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. Conclusion: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7. PMID:25969640

  16. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    PubMed

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  17. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study

    PubMed Central

    Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.

    2017-01-01

    Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067

  18. Machine learning for prediction of all-cause mortality in patients with suspected coronary artery disease: a 5-year multicentre prospective registry analysis

    PubMed Central

    Motwani, Manish; Dey, Damini; Berman, Daniel S.; Germano, Guido; Achenbach, Stephan; Al-Mallah, Mouaz H.; Andreini, Daniele; Budoff, Matthew J.; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; Cury, Ricardo C.; Delago, Augustin; Gomez, Millie; Gransar, Heidi; Hadamitzky, Martin; Hausleiter, Joerg; Hindoyan, Niree; Feuchtner, Gudrun; Kaufmann, Philipp A.; Kim, Yong-Jin; Leipsic, Jonathon; Lin, Fay Y.; Maffei, Erica; Marques, Hugo; Pontone, Gianluca; Raff, Gilbert; Rubinshtein, Ronen; Shaw, Leslee J.; Stehli, Julia; Villines, Todd C.; Dunning, Allison; Min, James K.; Slomka, Piotr J.

    2017-01-01

    Aims Traditional prognostic risk assessment in patients undergoing non-invasive imaging is based upon a limited selection of clinical and imaging findings. Machine learning (ML) can consider a greater number and complexity of variables. Therefore, we investigated the feasibility and accuracy of ML to predict 5-year all-cause mortality (ACM) in patients undergoing coronary computed tomographic angiography (CCTA), and compared the performance to existing clinical or CCTA metrics. Methods and results The analysis included 10 030 patients with suspected coronary artery disease and 5-year follow-up from the COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter registry. All patients underwent CCTA as their standard of care. Twenty-five clinical and 44 CCTA parameters were evaluated, including segment stenosis score (SSS), segment involvement score (SIS), modified Duke index (DI), number of segments with non-calcified, mixed or calcified plaques, age, sex, gender, standard cardiovascular risk factors, and Framingham risk score (FRS). Machine learning involved automated feature selection by information gain ranking, model building with a boosted ensemble algorithm, and 10-fold stratified cross-validation. Seven hundred and forty-five patients died during 5-year follow-up. Machine learning exhibited a higher area-under-curve compared with the FRS or CCTA severity scores alone (SSS, SIS, DI) for predicting all-cause mortality (ML: 0.79 vs. FRS: 0.61, SSS: 0.64, SIS: 0.64, DI: 0.62; P< 0.001). Conclusions Machine learning combining clinical and CCTA data was found to predict 5-year ACM significantly better than existing clinical or CCTA metrics alone. PMID:27252451

  19. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit.

    PubMed

    Pedicelli, Alessandro; Verdolotti, Tommaso; Pompucci, Angelo; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo

    2011-12-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180° and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of "CT-like" MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room.

  20. Vertebrobasilar ectasia in patients with lacunar stroke: the secondary prevention of small subcortical strokes trial.

    PubMed

    Nakajima, Makoto; Pearce, Lesly A; Ohara, Nobuyuki; Field, Thalia S; Bazan, Carlos; Anderson, David C; Hart, Robert G; Benavente, Oscar R

    2015-05-01

    The clinical implications of vertebrobasilar ectasia (VBE) in patients with cerebral small-artery disease are not well defined. We investigated whether VBE is associated with recurrent stroke, major hemorrhage, and death in a large cohort of patients with recent lacunar stroke. Maximum diameters of the vertebral and basilar arteries were measured by magnetic resonance angiography and computed tomographic angiography in 2621 participants in the Secondary Prevention of Small Subcortical Strokes trial. VBE was defined a priori as basilar artery greater than 4.5 mm and/or vertebral artery greater than 4.0 mm. Patient characteristics and risks of stroke recurrence and mortality during follow-up (median, 3.5 years) were compared between patients with and without VBE. VBE affecting 1 or more arteries was present in 200 (7.6%) patients. Patient features independently associated with VBE were increasing age, male sex, white race ethnicity, hypertension, and higher baseline diastolic blood pressure. Baseline systolic blood pressure was inversely associated with VBE. After adjustment for other risk factors, VBE was not predictive of recurrent stroke (hazard ratio [HR], 1.3; 95% confidence interval [CI], .85-1.9) or major hemorrhage (HR, 1.5; CI, .94-2.6), but was of death (HR, 1.7; CI, 1.1-2.7). In this large well-characterized cohort of patients with recent lacunar stroke, VBE was predictive of death but not of recurrent stroke or major hemorrhage. In these exploratory analyses, the frequency of VBE was directly related to diastolic blood pressure but inversely related to systolic blood pressure. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Prognostic value of computed tomographic coronary angiography and exercise electrocardiography for cardiovascular events

    PubMed Central

    Kim, Kye-Hwan; Jeon, Kyung Nyeo; Kang, Min Gyu; Ahn, Jong Hwa; Koh, Jin-Sin; Park, Yongwhi; Hwang, Seok-Jae; Jeong, Young-Hoon; Kwak, Choong Hwan; Hwang, Jin-Yong; Park, Jeong Rang

    2016-01-01

    Background/Aims: This study is a head-to-head comparison of predictive values for long-term cardiovascular outcomes between exercise electrocardiography (ex-ECG) and computed tomography coronary angiography (CTCA) in patients with chest pain. Methods: Four hundred and forty-two patients (mean age, 56.1 years; men, 61.3%) who underwent both ex-ECG and CTCA for evaluation of chest pain were included. For ex-ECG parameters, the patients were classified according to negative or positive results, and Duke treadmill score (DTS). Coronary artery calcium score (CACS), presence of plaque, and coronary artery stenosis were evaluated as CTCA parameters. Cardiovascular events for prognostic evaluation were defined as unstable angina, acute myocardial infarction, revascularization, heart failure, and cardiac death. Results: The mean follow-up duration was 2.8 ± 1.1 years. Fifteen patients experienced cardiovascular events. Based on pretest probability, the low- and intermediate-risks of coronary artery disease were 94.6%. Odds ratio of CACS > 40, presence of plaque, coronary stenosis ≥ 50% and DTS ≤ 4 were significant (3.79, p = 0.012; 9.54, p = 0.030; 6.99, p < 0.001; and 4.58, p = 0.008, respectively). In the Cox regression model, coronary stenosis ≥ 50% (hazard ratio, 7.426; 95% confidence interval, 2.685 to 20.525) was only significant. After adding DTS ≤ 4 to coronary stenosis ≥ 50%, the integrated discrimination improvement and net reclassification improvement analyses did not show significant. Conclusions: CTCA was better than ex-ECG in terms of predicting long-term outcomes in low- to intermediate-risk populations. The predictive value of the combination of CTCA and ex-ECG was not superior to that of CTCA alone. PMID:27017387

  2. Machine learning for prediction of all-cause mortality in patients with suspected coronary artery disease: a 5-year multicentre prospective registry analysis.

    PubMed

    Motwani, Manish; Dey, Damini; Berman, Daniel S; Germano, Guido; Achenbach, Stephan; Al-Mallah, Mouaz H; Andreini, Daniele; Budoff, Matthew J; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; Cury, Ricardo C; Delago, Augustin; Gomez, Millie; Gransar, Heidi; Hadamitzky, Martin; Hausleiter, Joerg; Hindoyan, Niree; Feuchtner, Gudrun; Kaufmann, Philipp A; Kim, Yong-Jin; Leipsic, Jonathon; Lin, Fay Y; Maffei, Erica; Marques, Hugo; Pontone, Gianluca; Raff, Gilbert; Rubinshtein, Ronen; Shaw, Leslee J; Stehli, Julia; Villines, Todd C; Dunning, Allison; Min, James K; Slomka, Piotr J

    2017-02-14

    Traditional prognostic risk assessment in patients undergoing non-invasive imaging is based upon a limited selection of clinical and imaging findings. Machine learning (ML) can consider a greater number and complexity of variables. Therefore, we investigated the feasibility and accuracy of ML to predict 5-year all-cause mortality (ACM) in patients undergoing coronary computed tomographic angiography (CCTA), and compared the performance to existing clinical or CCTA metrics. The analysis included 10 030 patients with suspected coronary artery disease and 5-year follow-up from the COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter registry. All patients underwent CCTA as their standard of care. Twenty-five clinical and 44 CCTA parameters were evaluated, including segment stenosis score (SSS), segment involvement score (SIS), modified Duke index (DI), number of segments with non-calcified, mixed or calcified plaques, age, sex, gender, standard cardiovascular risk factors, and Framingham risk score (FRS). Machine learning involved automated feature selection by information gain ranking, model building with a boosted ensemble algorithm, and 10-fold stratified cross-validation. Seven hundred and forty-five patients died during 5-year follow-up. Machine learning exhibited a higher area-under-curve compared with the FRS or CCTA severity scores alone (SSS, SIS, DI) for predicting all-cause mortality (ML: 0.79 vs. FRS: 0.61, SSS: 0.64, SIS: 0.64, DI: 0.62; P< 0.001). Machine learning combining clinical and CCTA data was found to predict 5-year ACM significantly better than existing clinical or CCTA metrics alone. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  3. The side-to-side fashion for individual distal coronary anastomosis using venous conduit.

    PubMed

    Kato, Takayoshi; Tsunekawa, Tomohiro; Motoji, Yusuke; Hirakawa, Akihiro; Okawa, Yasuhide; Tomita, Shinji

    2017-04-01

    Regarding to coronary artery bypass grafting (CABG), the end-to-side anastomosis (ESA) has been performed as a gold standard. Recently, the effectiveness of the distal side-to-side anastomosis (SSA) in CABG using internal mammary artery has been reported. The benefit of SSA comparing to ESA also has been disclosed by computing simulation. However, use of SSA by venous conduit for individual CABG has not been reported. In this study, we investigated feasibility of SSA. From January 2013 to October 2014, we conducted 114 CABGs. There were 92 venous distal anastomoses without sequential anastomotic site (61 SSA and 31 ESA). The anastomosis was evaluated before discharge and at 1 year after the procedure by angiography or multi-detector row computed tomographic coronary angiography. The median values for time to anastomosis were 13 min in the two group (p = 0.89). There was no revision of anastomosis in both groups. Additional stitches for hemostasis were required significantly less in SSA than ESA (18.0 vs 45.2 %, respectively, p < 0.05). Early angiographic patency; 96.6 % for SSA vs 93.5 % for ESA (p = 0.50), and percentage of good anastomotic figure; 91.2 % for SSA vs 87.1 % for ESA (p = 0.54) were similar in both groups. The angiographic patency at 1 year were 92.9 % for SSA and 81.0 % for ESA (p = 0.16). There was no predictive factor for early and late graft failure. Our study showed feasibility of SSA using venous conduit in individual CABG based on early and mid-term angiographic results. This anastomotic fashion is easy to perform and maybe beneficial in blood flow pattern.

  4. Vertebrobasilar system computed tomographic angiography in central vertigo

    PubMed Central

    Paşaoğlu, Lale

    2017-01-01

    Abstract The incidence of vertigo in the population is 20% to 30% and one-fourth of the cases are related to central causes. The aim of this study was to evaluate computed tomography angiography (CTA) findings of the vertebrobasilar system in central vertigo without stroke. CTA and magnetic resonance images of patients with vertigo were retrospectively evaluated. One hundred twenty-nine patients suspected of having central vertigo according to history, physical examination, and otological and neurological tests without signs of infarction on diffusion-weighted magnetic resonance imaging were included in the study. The control group included 120 patients with similar vascular disease risk factors but without vertigo. Vertebral and basilar artery diameters, hypoplasias, exit-site variations of vertebral artery, vertebrobasilar tortuosity, and stenosis of ≥50% detected on CTA were recorded for all patients. Independent-samples t test was used in variables with normal distribution, and Mann–Whitney U test in non-normal distribution. The difference of categorical variable distribution according to groups was analyzed with χ2 and/or Fisher exact test. Vertebral artery hypoplasia and ≥50% stenosis were seen more often in the vertigo group (P = 0.000, <0.001). Overall 78 (60.5%) vertigo patients had ≥50% stenosis, 54 (69.2%) had stenosis at V1 segment, 9 (11.5%) at V2 segment, 2 (2.5%) at V3 segment, and 13 (16.6%) at V4 segment. Both vertigo and control groups had similar basilar artery hypoplasia and ≥50% stenosis rates (P = 0.800, >0.05). CTA may be helpful to clarify the association between abnormal CTA findings of vertebral arteries and central vertigo. This article reveals the opportunity to diagnose posterior circulation abnormalities causing central vertigo with a feasible method such as CTA. PMID:28328808

  5. Vertebrobasilar system computed tomographic angiography in central vertigo.

    PubMed

    Paşaoğlu, Lale

    2017-03-01

    The incidence of vertigo in the population is 20% to 30% and one-fourth of the cases are related to central causes. The aim of this study was to evaluate computed tomography angiography (CTA) findings of the vertebrobasilar system in central vertigo without stroke.CTA and magnetic resonance images of patients with vertigo were retrospectively evaluated. One hundred twenty-nine patients suspected of having central vertigo according to history, physical examination, and otological and neurological tests without signs of infarction on diffusion-weighted magnetic resonance imaging were included in the study. The control group included 120 patients with similar vascular disease risk factors but without vertigo. Vertebral and basilar artery diameters, hypoplasias, exit-site variations of vertebral artery, vertebrobasilar tortuosity, and stenosis of ≥50% detected on CTA were recorded for all patients. Independent-samples t test was used in variables with normal distribution, and Mann-Whitney U test in non-normal distribution. The difference of categorical variable distribution according to groups was analyzed with χ and/or Fisher exact test.Vertebral artery hypoplasia and ≥50% stenosis were seen more often in the vertigo group (P = 0.000, <0.001). Overall 78 (60.5%) vertigo patients had ≥50% stenosis, 54 (69.2%) had stenosis at V1 segment, 9 (11.5%) at V2 segment, 2 (2.5%) at V3 segment, and 13 (16.6%) at V4 segment. Both vertigo and control groups had similar basilar artery hypoplasia and ≥50% stenosis rates (P = 0.800, >0.05).CTA may be helpful to clarify the association between abnormal CTA findings of vertebral arteries and central vertigo.This article reveals the opportunity to diagnose posterior circulation abnormalities causing central vertigo with a feasible method such as CTA.

  6. Three-dimensional brain arteriovenous malformation models for clinical use and resident training.

    PubMed

    Dong, Mengqi; Chen, Guangzhong; Li, Jianyi; Qin, Kun; Ding, Xiaowen; Peng, Chao; Zhou, Dong; Lin, Xiaofeng

    2018-01-01

    To fabricate three-dimensional (3D) models of brain arteriovenous malformation (bAVM) and report our experience with customized 3D printed models of patients with bAVM as an educational and clinical tool for patients, doctors, and surgical residents. Using computerized tomography angiography (CTA) or digital subtraction angiography (DSA) images, the rapid prototyping process was completed with specialized software and "in-house" 3D printing service. Intraoperative validation of model fidelity was performed by comparing to DSA images of the same patient during the endovascular treatment process. 3D bAVM models were used for preoperative patient education and consultation, surgical planning, and resident training. 3D printed bAVM models were successful made. By neurosurgeons' evaluation, the printed models precisely replicated the actual bAVM structure of the same patients (n = 7, 97% concordance, range 95%-99% with average of < 2 mm variation). The use of 3D models was associated shorter time for preoperative patient education and consultation, higher acceptable of the procedure for patients and relatives, shorter time between obtaining intraoperative DSA data and the start of endovascular treatment. Thirty surgical residents from residency programs tested the bAVM models and provided feedback on their resemblance to real bAVM structures and the usefulness of printed solid model as an educational tool. Patient-specific 3D printed models of bAVM can be constructed with high fidelity. 3D printed bAVM models were proven to be helpful in preoperative patient consultation, surgical planning, and resident training. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  7. Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oender, Hakan, E-mail: drhakanonder@hotmail.com; Oguzkurt, Levent; Guer, Serkan

    To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Ofmore » the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.« less

  8. Initial clinical application of a robotically steerable catheter system in endovascular aneurysm repair.

    PubMed

    Riga, Celia; Bicknell, Colin; Cheshire, Nicholas; Hamady, Mohamad

    2009-04-01

    To report the initial clinical use of a robotically steerable catheter during endovascular aneurysm repair (EVAR) in order to assess this novel and innovative approach in a clinical setting. Following a series of in-vitro studies and procedure rehearsals using a pulsatile silicon aneurysm model, a 78-year-old man underwent robot-assisted EVAR of a 5.9-cm infrarenal abdominal aortic aneurysm. During the standard procedure, a 14-F remotely steerable robotic catheter was used to successfully navigate through the aneurysm sac, cannulate the contralateral limb of a bifurcated stent-graft under fluoroscopic guidance, and place stiff wires using fine and controlled movements. The procedure was completed successfully. There were no postoperative complications, and computed tomographic angiography prior to discharge and at 3 months confirmed that the stent-graft remained in good position, with no evidence of an endoleak. EVAR using robotically-steerable catheters is feasible. This technology may simplify more complex procedures by increasing the accuracy of vessel cannulation and perhaps reduce procedure times and radiation exposure to the patient and operator.

  9. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    PubMed

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  10. Cardiac radiology: centenary review.

    PubMed

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  11. An Unruptured Aneurysm Coexisting with an Infundibular Dilatation: A Case Report.

    PubMed

    Kitamura, Takao; Murai, Yasuo; Shirokane, Kazutaka; Matano, Fumihiro; Kitamura, Takayuki; Morita, Akio

    2016-01-01

    Infundibular dilatation (ID) is a funnel-shaped enlargement of the origin of cerebral arteries. The coexistence of an aneurysm and ID is relatively rare. Patients with IDs are rarely followed up. However, some IDs have been reported to develop into aneurysms with subsequent rupture. Here we report on a case of an aneurysm that coexisted with ID of the posterior communicating artery. A 51-year-old woman underwent magnetic resonance imaging (MRI) to check for aneurysms and other problems. MRI revealed an unruptured aneurysm of the right internal carotid artery, for which the patient was admitted to our hospital. Three-dimensional computed tomographic angiography revealed an aneurysm, which protruded outward, and ID of the posterior communicating artery, which protruded inward. A right pterional craniotomy was performed with aneurysm clipping. The postoperative course was uneventful. In this report, we demonstrate operative views of the aneurysm and ID with the use of neuroendoscopy. ID can develop into a true arterial aneurysm and potentially rupture. Therefore, we need to observe the patients with IDs carefully, particularly in young women.

  12. Vesselness propagation: a fast interactive vessel segmentation method

    NASA Astrophysics Data System (ADS)

    Cai, Wenli; Dachille, Frank; Harris, Gordon J.; Yoshida, Hiroyuki

    2006-03-01

    With the rapid development of multi-detector computed tomography (MDCT), resulting in increasing temporal and spatial resolution of data sets, clinical use of computed tomographic angiography (CTA) is rapidly increasing. Analysis of vascular structures is much needed in CTA images; however, the basis of the analysis, vessel segmentation, can still be a challenging problem. In this paper, we present a fast interactive method for CTA vessel segmentation, called vesselness propagation. This method is a two-step procedure, with a pre-processing step and an interactive step. During the pre-processing step, a vesselness volume is computed by application of a CTA transfer function followed by a multi-scale Hessian filtering. At the interactive stage, the propagation is controlled interactively in terms of the priority of the vesselness. This method was used successfully in many CTA applications such as the carotid artery, coronary artery, and peripheral arteries. It takes less than one minute for a user to segment the entire vascular structure. Thus, the proposed method provides an effective way of obtaining an overview of vascular structures.

  13. External and internal macromorphology in 3D-reconstructed maxillary molars using computerized X-ray microtomography.

    PubMed

    Bjørndal, L; Carlsen, O; Thuesen, G; Darvann, T; Kreiborg, S

    1999-01-01

    The aim of this study was to perform a qualitative analysis of the relationship between the external and internal macromorphology of the root complex and to use fractal dimension analysis to determine the correlation between the shape of the outer surface of the root and the shape of the root canal. On the basis of X-ray computed transaxial microtomography, a qualitative and quantitative analysis of the external and internal macromorphology of the root complex in permanent maxillary molars was performed using well-defined macromorphological variables and fractal dimension analysis. Five maxillary molars were placed between a microfocus X-ray tube with a focal spot size of 0.07 mm, a Thomson-SCF image intensifier, and a CCD camera compromising a detector for the tomograph. Between 100 and 240 tomographic 2D slices were made of each tooth. Assembling slices for 3D volume was carried out with subsequent median noise filtering. Segmentation into enamel, dentine and pulp space was achieved through thresholding followed by morphological filtering. Surface representations were then constructed. A useful visualization of the tooth was created by making the dental hard tissues transparent and the pulp chamber and root-canal system opaque. On this basis it became possible to assess the relationship between the external and internal macromorphology of the crown and root complex. There was strong agreement between the number, position and cross-section of the root canals and the number, position and degree of manifestation of the root complex macrostructures. Data from a fractal dimension analysis also showed a high correlation between the shape of the root canals and the corresponding roots. It is suggested that these types of 3D volumes constitute a platform for preclinical training in fundamental endodontic procedures.

  14. Coronary angiography

    MedlinePlus

    ... Angiogram - coronary; Coronary artery disease - angiography; CAD - angiography; Angina - angiography; Heart disease - angiography ... Coronary angiography may be done if: You have angina for the first time. Your angina that is ...

  15. CT Angiography (CTA)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z CT Angiography (CTA) Computed tomography angiography (CTA) uses an ... are the limitations of CT Angiography? What is CT Angiography? Angiography is a minimally invasive medical test ...

  16. Volume changes of autogenous bone after sinus lifting and grafting procedures: a 6-year computerized tomographic follow-up.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Guidetti, Franco; Califano, Luigi; Bufo, Pantaleo; Sbordone, Ludovico

    2013-04-01

    To evaluate long-term bone remodelling of autografts over time (annually, for 6 years), comparing the block and particulate bone procedures for sinus floor elevation, as well as to evaluate the survival of positioned dental implants. Twenty-three sinus lift procedures with autogenous bone were performed: seven sinus lift procedures using particulate graft and 10 with block autogenous bone were performed in 17 patients. Employing a software program, pre- and post-surgical computerized tomography (CT) scans were used to compare the volume (V) and density (D) of inlay grafts over time (up to 6 years), and to determine the percentage of remaining bone (%R). All variable (V, D and %R) measurements were then compared statistically. At the 6-year survey for block form, a resorption of 21.5% was seen, whereas for particulate grafts there was a resorption of 39.2%. Both groups exhibited bone remodelling between the first and second follow-up which was significant regarding volume for the block form and regarding density for the particulate group. During the initial period of healing, the cortico-cancellous block bone grafted into the maxillary sinus underwent a negative remodelling of the volume, which is most probably due to graft cortex resorption, coupled with, primarily, an increase in density in the spongious area; for the particulate grafts, significant augmentations in density were obtained. The lack of significant differences among volumes was due to the wide degree of dispersion of the data. The rough data presented in this paper seem to support the use of a bone-block grafting procedure in maxillary sinus augmentation. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Surgically Assisted Rapid Palatomaxillary Expansion With or Without Pterygomaxillary Disjunction: A Systematic Review and Meta-Analysis.

    PubMed

    Hamedi Sangsari, Adrien; Sadr-Eshkevari, Pooyan; Al-Dam, Ahmed; Friedrich, Reinhard E; Freymiller, Earl; Rashad, Ashkan

    2016-02-01

    The purpose of this review was to evaluate the outcome measurements of anterior expansion, posterior expansion, and complications after surgically assisted rapid palatal expansion (SARPE) with or without pterygomaxillary disjunction (PMD). A computerized database search was performed using PubMed, CINAHL, Cochrane, Scopus, and Web of Science. Then, a computerized search was conducted in Google Scholar and ProQuest to overcome publication bias. From the original 125 combined results, 3 met the inclusion criteria. The Quality Assessment Tool for Quantitative Studies of the Effective Public Health Practice Project assessed 2 articles as weak and 1 as moderate. The systematic review included a total of 48 patients (11 male and 37 female). For 25 patients, SARPE was performed with PMD and for 23 patients SARPE was performed without PMD. A tooth-borne fixed hyrax-type palatal expansion screw appliance was used for all cases, activated 1 to 2 mm intraoperatively, and, after a latency period of 3 to 7 days, activated 0.5 to 0.6 mm per day for 38 patients and 0.25 mm for the other 10 until adequate expansion. Postexpansion retention was performed using ligature wired hyrax in 18 patients for 4 months. Comparisons were based on cone-beam computed tomographic projections, study models only, or a combination of study models, anteroposterior cephalometric radiographs, and occlusal radiographs. The time to measure the changes ranged from before fixed orthodontic retention to 6 months after the completion of active expansion. A meta-analysis was possible only for anterior (intercanine) and posterior (inter-molar) dental expansions. The literature is inconclusive regarding the effect of PMD on the outcomes of SARPE. Further controlled trials are needed. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Peritoneal mesothelioma presenting as an acute surgical abdomen due to jejunal perforation.

    PubMed

    Salemis, Nikolaos S; Tsiambas, Evangelos; Gourgiotis, Stavros; Mela, Ageliki; Karameris, Andreas; Tsohataridis, Efstathios

    2007-11-01

    Peritoneal mesothelioma is a rare disease associated with poor prognosis. Acute abdomen as the first presentation is an extremely rare occurrence. We report an exceptional case of a patient who was found to have a jejunal perforation due to infiltration of peritoneal mesothelioma. A 62-year-old man was admitted with clinical signs of peritonitis. Computerized tomographic scans showed a mass distal to the ligament of Treitz, thickening of the mesentery and a small amount of ascites. Emergency laparotomy revealed a perforated tumor 15 cm distal to the ligament of Treitz and diffuse peritoneal disease. Segmental small bowel resection and suboptimal cytoreduction were performed. Histopathology and immunohistochemistry showed infiltration of malignant mesothelioma. During the postoperative period pleural mesothelioma was also diagnosed. Despite adjuvant chemotherapy, the patient died of disseminated progressive disease 7 months after surgery. Peritoneal mesothelioma is a rare malignancy with grim prognosis. Small bowel involvement is a poor prognostic indicator. Our case of a small bowel perforation due to direct infiltration by peritoneal mesothelioma appears to be the first reported in the English literature.

  20. Current Trends in the Management of Abdominal Aortic Aneurysms

    PubMed Central

    Harris, K.A.; Ameli, F. Michael; Louis, E.L. St.

    1987-01-01

    The treatment of abdominal aortic aneurysm has undergone dramatic changes over the last three decades. More sophisticated diagnostic techniques have allowed early elective repair to be carried out. Improvement has resulted in both morbidity and mortality rates. Investigations such as ultrasound, computerized tomographic scanning and arteriography allow easy confirmation of the diagnosis of aortic aneurysms and permit a better assessment of the extent prior to surgical intervention. Improvement in the pre-operative management, particularly in relation to cardiac, renal, and pulmonary disease, has led to greatly improved results. The most important change in surgical technique has been repair of the aneurysm rather than resection. Combined with better post-operative intensive care units, this development has contributed to the improved morbidity and mortality rates. Although the complication rate of elective repair is low, the major cause of death remains myocardial infarction. As a result of all these improvements, indication for repair of abdominal aortic aneurysms has been extended to patients over the age of 80. Following surgical repair, most patients can be expected to return to normal lifestyles and lifespans. ImagesFigure 2Figure 3Figure 4 PMID:21263973

  1. Computed Tomographic Angiographic Perforator Localization for Virtual Surgical Planning of Osteocutaneous Fibular Free Flaps in Head and Neck Reconstruction.

    PubMed

    Ettinger, Kyle S; Alexander, Amy E; Arce, Kevin

    2018-04-10

    Virtual surgical planning (VSP), computer-aided design and computer-aided modeling, and 3-dimensional printing are 3 distinct technologies that have become increasingly used in head and neck oncology and microvascular reconstruction. Although each of these technologies has long been used for treatment planning in other surgical disciplines, such as craniofacial surgery, trauma surgery, temporomandibular joint surgery, and orthognathic surgery, its widespread use in head and neck reconstructive surgery remains a much more recent event. In response to the growing trend of VSP being used for the planning of fibular free flaps in head and neck reconstruction, some surgeons have questioned the technology's implementation based on its inadequacy in addressing other reconstructive considerations beyond hard tissue anatomy. Detractors of VSP for head and neck reconstruction highlight its lack of capability in accounting for multiple reconstructive factors, such as recipient vessel selection, vascular pedicle reach, need for dead space obliteration, and skin paddle perforator location. It is with this premise in mind that the authors report on a straightforward technique for anatomically localizing peroneal artery perforators during VSP for osteocutaneous fibular free flaps in which bone and a soft tissue skin paddle are required for ablative reconstruction. The technique allows for anatomic perforator localization during the VSP session based solely on data existent at preoperative computed tomographic angiography (CTA); it does not require any modifications to preoperative clinical workflows. It is the authors' presumption that many surgeons in the field are unaware of this planning capability within the context of modern VSP for head and neck reconstruction. The primary purpose of this report is to introduce and further familiarize surgeons with the technique of CTA perforator localization as a method of improving intraoperative fidelity for VSP of osteocutaneous fibular free flaps. Copyright © 2018. Published by Elsevier Inc.

  2. Validating a Predictive Model of Acute Advanced Imaging Biomarkers in Ischemic Stroke.

    PubMed

    Bivard, Andrew; Levi, Christopher; Lin, Longting; Cheng, Xin; Aviv, Richard; Spratt, Neil J; Lou, Min; Kleinig, Tim; O'Brien, Billy; Butcher, Kenneth; Zhang, Jingfen; Jannes, Jim; Dong, Qiang; Parsons, Mark

    2017-03-01

    Advanced imaging to identify tissue pathophysiology may provide more accurate prognostication than the clinical measures used currently in stroke. This study aimed to derive and validate a predictive model for functional outcome based on acute clinical and advanced imaging measures. A database of prospectively collected sub-4.5 hour patients with ischemic stroke being assessed for thrombolysis from 5 centers who had computed tomographic perfusion and computed tomographic angiography before a treatment decision was assessed. Individual variable cut points were derived from a classification and regression tree analysis. The optimal cut points for each assessment variable were then used in a backward logic regression to predict modified Rankin scale (mRS) score of 0 to 1 and 5 to 6. The variables remaining in the models were then assessed using a receiver operating characteristic curve analysis. Overall, 1519 patients were included in the study, 635 in the derivation cohort and 884 in the validation cohort. The model was highly accurate at predicting mRS score of 0 to 1 in all patients considered for thrombolysis therapy (area under the curve [AUC] 0.91), those who were treated (AUC 0.88) and those with recanalization (AUC 0.89). Next, the model was highly accurate at predicting mRS score of 5 to 6 in all patients considered for thrombolysis therapy (AUC 0.91), those who were treated (0.89) and those with recanalization (AUC 0.91). The odds ratio of thrombolysed patients who met the model criteria achieving mRS score of 0 to 1 was 17.89 (4.59-36.35, P <0.001) and for mRS score of 5 to 6 was 8.23 (2.57-26.97, P <0.001). This study has derived and validated a highly accurate model at predicting patient outcome after ischemic stroke. © 2017 American Heart Association, Inc.

  3. Ultrahigh resolution and brilliance laser wakefield accelerator betatron x-ray source for rapid in vivo tomographic microvasculature imaging in small animal models

    NASA Astrophysics Data System (ADS)

    Fourmaux, Sylvain; Kieffer, Jean-Claude; Krol, Andrzej

    2017-03-01

    We are developing ultrahigh spatial resolution (FWHM < 2 μm) high-brilliance x-ray source for rapid in vivo tomographic microvasculature imaging micro-CT angiography (μCTA) in small animal models using optimized contrast agent. It exploits Laser Wakefield Accelerator (LWFA) betatron x-ray emission phenomenon. Ultrashort high-intensity laser pulse interacting with a supersonic gas jet produces an ion cavity ("bubble") in the plasma in the wake of the laser pulse. Electrons that are injected into this bubble gain energy, perform wiggler-like oscillations and generate burst of incoherent x-rays with characteristic duration time comparable to the laser pulse duration, continuous synchrotron-like spectral distribution that might extend to hundreds keV, very high brilliance, very small focal spot and highly directional emission in the cone-beam geometry. Such LWFA betatron x-ray source created in our lab produced 1021 -1023 photonsṡ shot-1ṡmrad-2ṡmm-2/0.1%bw with mean critical energy in the12-30 keV range. X-ray source size for a single laser shot was FWHM=1.7 μm x-ray beam divergence 20-30 mrad, and effective focal spot size for multiple shots FWHM= 2 μm. Projection images of simple phantoms and complex biological objects including insects and mice were obtained in single laser shots. We conclude that ultrahigh spatial resolution μCTA (FWHM 2 μm) requiring thousands of projection images could be accomplished using LWFA betatron x-ray radiation in approximately 40 s with our existing 220 TW laser and sub seconds with next generation of ultrafast lasers and x-ray detectors, as opposed to several hours required using conventional microfocal x-ray tubes. Thus, sub second ultrahigh resolution in vivo microtomographic microvasculature imaging (in both absorption and phase contrast mode) in small animal models of cancer and vascular diseases will be feasible with LWFA betatron x-ray source.

  4. Gadolinium-enhanced magnetic resonance angiography in renal artery stenosis: comparison with digital subtraction angiography.

    PubMed

    Law, Y M; Tay, K H; Gan, Y U; Cheah, F K; Tan, B S

    2008-04-01

    To evaluate the accuracy of gadolinium-enhanced magnetic resonance angiography in assessing renal artery stenosis compared to catheter digital subtraction angiography. Retrospective study. Singapore General Hospital. Records of patients who underwent magnetic resonance angiography as well as digital subtraction angiography for assessment of renal artery stenosis from January 2003 to December 2005 were reviewed. There were 27 patients (14 male, 13 female) with a mean age of 62 (range, 44-77) years. There were 10 patients with renal transplants; their native renal arteries were not evaluated. Each of the two experienced interventional and body magnetic resonance radiologists, who were blinded to the results, reviewed the digital subtraction angiography and magnetic resonance angiography images respectively. Digital subtraction angiography was used as the standard of reference. A total of 39 renal arteries from these 27 patients were evaluated. One of the arteries was previously stented and could not be assessed with magnetic resonance angiography due to severe artefacts. Of the remaining 38 renal arteries, two were graded as normal, seven as having mild stenosis (<50%), eight as having moderate stenosis (> or =50% but <75%), and 21 as having severe stenosis (> or =75%). Magnetic resonance angiography and digital subtraction angiography were concordant in 89% of the arteries; magnetic resonance angiography overestimated the degree of stenosis in 8% and underestimated it in 3% of them. In the evaluation of clinically significant renal artery stenosis (> or =50%) with magnetic resonance angiography, the overall sensitivity, specificity, positive predictive value, and negative predictive value were 97%, 67%, 90%, and 86% respectively. The sensitivity and specificity of magnetic resonance angiography in transplant renal artery stenosis was 100%. CONCLUSION. Our experience suggested that gadolinium-enhanced magnetic resonance angiography is a sensitive non-invasive modality useful in the assessment of clinically significant renal artery stenosis.

  5. How I Do It: Cone-Beam CT during Transarterial Chemoembolization for Liver Cancer

    PubMed Central

    Tacher, Vania; Radaelli, Alessandro; Lin, MingDe

    2015-01-01

    Cone-beam computed tomography (CBCT) is an imaging technique that provides computed tomographic (CT) images from a rotational scan acquired with a C-arm equipped with a flat panel detector. Utilizing CBCT images during interventional procedures bridges the gap between the world of diagnostic imaging (typically three-dimensional imaging but performed separately from the procedure) and that of interventional radiology (typically two-dimensional imaging). CBCT is capable of providing more information than standard two-dimensional angiography in localizing and/or visualizing liver tumors (“seeing” the tumor) and targeting tumors though precise microcatheter placement in close proximity to the tumors (“reaching” the tumor). It can also be useful in evaluating treatment success at the time of procedure (“assessing” treatment success). CBCT technology is rapidly evolving along with the development of various contrast material injection protocols and multiphasic CBCT techniques. The purpose of this article is to provide a review of the principles of CBCT imaging, including purpose and clinical evidence of the different techniques, and to introduce a decision-making algorithm as a guide for the routine utilization of CBCT during transarterial chemoembolization of liver cancer. © RSNA, 2015 Online supplemental material is available for this article. PMID:25625741

  6. Optoacoustic angiography of peripheral vasculature

    NASA Astrophysics Data System (ADS)

    Ermilov, Sergey; Su, Richard; Zamora, Mario; Hernandez, Travis; Nadvoretsky, Vyacheslav; Oraevsky, Alexander

    2012-02-01

    We developed a new optoacoustic microangiography system (OmAS) intended for in-vivo vascular imaging of a human finger. The system employs an arc-shaped acoustic array that is rotated 360 degrees around the finger providing optoacoustic data necessary for tomographic reconstruction of the three-dimensional images of a finger. A near-infrared Q-switched laser is used to generate optoacoustic signals with increased contrast of blood vessels. The laser is coupled through two randomized fiberoptic bundles oriented in orthogonal optoacoustic mode. To demonstrate OmAS capabilities, we present a time-series of optoacoustic images of a human finger taken after the hypothermia stress test. The images show a detailed vascular anatomy of a finger down to the capillary level. A series of quick 30s scans allowed us to visualize the thermoregulatory response within the studied finger as it was manifested via vasomotor activity during the hypothermia recovery. We propose that the developed system can be used for diagnostics of various medical conditions that are manifested in change of the peripheral (finger) blood flow. Examples of the medical conditions that could be diagnosed and staged using the OmAS include the peripheral arterial disease (PAD), thrombosis, frostbite, and traumas.

  7. Myocardial scintigraphy with 201thallium in pediatric cardiology: A review of 52 cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjoerkhem, G.E.; Evander, E.; White, T.

    1990-01-01

    We report our experience of myocardial scintigraphy with 201thallium (201Tl) in 52 children, aged 4 days to 18 years, in which 80 studies were made primarily to demonstrate or exclude impaired myocardial perfusion. For analysis, the patients were divided into the following eight groups: group I, coronary artery malformations (five patients); group II, Kawasaki's syndrome (six patients); group III, arterial switch operation (seven patients); group IV, dilated cardiomyopathy (18 patients); group V, hypertrophic cardiomyopathy (four patients); group VI, myocardial dysfunction after surgery for congenital heart disease (five patients); group VII, pulmonary atresia (three patients); and group VIII, miscellaneous (four patients).more » Myocardial scintigraphy was performed with a planar or tomographic technique at rest or after exercise (four patients). Isotope-uptake defects, indicating impaired myocardial perfusion, were present in 14 patients, including small infants. Defects were seen in all groups except those with hypertrophic cardiomyopathy and pulmonary atresia. The absence of such defects in several of the patients with Kawasaki's syndrome was particularly valuable as it made coronary angiography unnecessary. In the other groups of patients myocardial scintigraphy was a valuable adjunct to other investigations.« less

  8. Software Development for Estimating the Conversion Factor (K-Factor) at Suitable Scan Areas, Relating the Dose Length Product to the Effective Dose.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi

    2017-05-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Toxic Myocarditis Caused by Acetaminophen in a Multidrug Overdose.

    PubMed

    Gosselin, Maxime; Dazé, Yann; Mireault, Pascal; Crahes, Marie

    2017-12-01

    We report the case of an 18-year-old woman with personality disorders who was hospitalized a few hours after suicidal ingestion of acetaminophen, quetiapine, acetylsalicylic acid, and ethanol. Twelve hours after admission, severe liver damage was evident, but the patient was stable and awaiting hepatic transplantation. Electrolytes were successfully controlled. The condition of the liver stabilized. Cardiac biomarkers then deteriorated unexpectedly. Localized ST-segment elevations were noted on electrocardiogram, but angiography ruled out myocardial infarction. A computed tomographic scan ruled out cerebral edema. The patient died of irreversible cardiac arrest 40 hours after admission. Heart failure remained unexplained, and the body underwent forensic autopsy.At autopsy, histologic findings were indicative of acute toxic myocarditis and were concluded to be caused by acetaminophen intoxication. Acetaminophen overdose is common and typically leads to liver failure requiring supportive treatment and emergency liver transplantation. Toxic myocarditis is an extremely rare complication of acetaminophen overdose. It has only been reported 4 times in the literature despite the widespread use and misuse of acetaminophen. Toxic myocarditis remains a possibility in many cases of overdose but can be overlooked in a clinical picture dominated by hepatorenal failure and encephalopathy. Clinicians and forensic pathologists should be aware of this rare potential complication.

  10. Carotid body size measured by computed tomographic angiography in individuals born prematurely.

    PubMed

    Bates, Melissa L; Welch, Brian T; Randall, Jess T; Petersen-Jones, Humphrey G; Limberg, Jacqueline K

    2018-05-24

    We tested the hypothesis that the carotid bodies would be smaller in individuals born prematurely or exposed to perinatal oxygen therapy when compared individuals born full term that did not receive oxygen therapy. A retrospective chart review was conducted on patients who underwent head/neck computed tomography angiography (CTA) at the Mayo Clinic between 10 and 40 years of age (n = 2503). Patients were identified as premature ( < 38 weeks) or receiving perinatal oxygen therapy by physician completion or billing codes (n = 16 premature and n = 7 receiving oxygen). Widest axial measurements of the carotid body images captured during the CTA were performed. Carotid body visualization was possible in 43% of patients and 52% of age, sex, and body mass index (BMI)-matched controls but only 17% of juvenile preterm subjects (p = 0.07). Of the carotid bodies that could be visualized, widest axial measurements of the carotid bodies in individuals born prematurely (n = 7, 34 ± 4 weeks gestation, birth weight: 2460 ± 454 g; average size: 2.5 ± 0.2 cm) or individuals exposed to perinatal oxygen therapy (n = 3, 38 ± 2 weeks gestation, Average size: 2.2 ± 0.1 cm) were not different when compared to controls (2.3 ± 0.2 cm and 2.3 ± 0.2 cm, respectively, p > 0.05). Carotid body size, as measured using CTA, is not smaller in adults born prematurely or exposed to perinatal oxygen therapy when compared to sex, age, and BMI-matched controls. However, carotid body visualization was lower in juvenile premature patients. The decreased ability to visualize the carotid bodies in these individuals may be a result of their prematurity. Copyright © 2018. Published by Elsevier B.V.

  11. Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal.

    PubMed

    Kaemmerer, Nadine; Brand, Michael; Hammon, Matthias; May, Matthias; Wuest, Wolfgang; Krauss, Bernhard; Uder, Michael; Lell, Michael M

    2016-10-01

    Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.

  12. Highly increased Troponin I levels following high-intensity endurance cycling may detect subclinical coronary artery disease in presumably healthy leisure sport cyclists: The North Sea Race Endurance Exercise Study (NEEDED) 2013.

    PubMed

    Skadberg, Øyvind; Kleiven, Øyunn; Bjørkavoll-Bergseth, Magnus; Melberg, Tor; Bergseth, Rolf; Selvåg, Jone; Auestad, Bjørn; Greve, Ole J; Dickstein, Kenneth; Aarsland, Torbjørn; Ørn, Stein

    2017-05-01

    Background Circulating cardiac troponin levels increase following prolonged intense physical exercise. The aim of this study was to identify participants with highly elevated cardiac troponins after prolonged, high intensity exercise, and to evaluate these for subclinical coronary artery disease. Methods and results Ninety-seven recreational cyclists without known cardiovascular disease or diabetes, participating in a 91 km mountain bike race were included, 74 (76%) were males, age: 43 ± 10 years, race duration: 4.2 (3.6-4.7) h. Blood samples, rest electrocardiogram and physical examination were obtained 24 h prior to, and at 0, 3 and 24 h following the race. Median cardiac troponin I level at baseline: 3.4 (2.1-4.9) ng/l (upper limit of normal: 30.0 ng/l). There was a highly significant ( p < 0.0001) increase in circulating cardiac troponin I in all participants: immediately following the race; 50.5 (28.5-71.9) ng/l, peaking at 3 h 69.3 (42.3-97.7) ng/l and declining at 24 h: 14.2 (8.5-27.9) ng/l. No cyclist had symptoms or rest electrocardiogram changes compatible with coronary artery disease during or following the race. Coronary artery disease was detected by coronary angiography in the three cyclists with the three of the four highest cardiac troponin values (>370 ng/l) at 3 and 24 h following the race. Computed tomographic coronary angiography was performed in an additional 10 riders with the subsequently highest cardiac troponin I values, without identifying underlying coronary artery disease. Conclusions This study suggests that there is a pathologic cardiac troponin I response following exercise in individuals with subclinical coronary artery disease. This response may be associated with an excessive cardiac troponin I increase at 3 and 24 h following prolonged high-intensity exercise.

  13. Improving prediction of recanalization in acute large-vessel occlusive stroke.

    PubMed

    Vanacker, P; Lambrou, D; Eskandari, A; Maeder, P; Meuli, R; Ntaios, G; Michel, P

    2014-06-01

    Recanalization in acute ischemic stroke with large-vessel occlusion is a potent indicator of good clinical outcome. To identify easily available clinical and radiologic variables predicting recanalization at various occlusion sites. All consecutive, acute stroke patients from the Acute STroke Registry and Analysis of Lausanne (2003-2011) who had a large-vessel occlusion on computed tomographic angiography (CTA) (< 12 h) were included. Recanalization status was assessed at 24 h (range: 12-48 h) with CTA, magnetic resonance angiography, or ultrasonography. Complete and partial recanalization (corresponding to the modified Treatment in Cerebral Ischemia scale 2-3) were grouped together. Patients were categorized according to occlusion site and treatment modality. Among 439 patients, 51% (224) showed complete or partial recanalization. In multivariate analysis, recanalization of any occlusion site was most strongly associated with endovascular treatment, including bridging therapy (odds ratio [OR] 7.1, 95% confidence interval [CI] 2.2-23.2), and less so with intravenous thrombolysis (OR 1.6, 95% CI 1.0-2.6) and recanalization treatments performed beyond guidelines (OR 2.6, 95% CI 1.2-5.7). Clot location (large vs. intermediate) and tandem pathology (the combination of intracranial occlusion and symptomatic extracranial stenosis) were other variables discriminating between recanalizers and non-recanalizers. For patients with intracranial occlusions, the variables significantly associated with recanalization after 24 h were: baseline National Institutes of Health Stroke Scale (NIHSS) (OR 1.04, 95% CI 1.02-1.1), Alberta Stroke Program Early CT Score (ASPECTS) on initial computed tomography (OR 1.2, 95% CI 1.1-1.3), and an altered level of consciousness (OR 0.2, 95% CI 0.1-0.5). Acute endovascular treatment is the single most important factor promoting recanalization in acute ischemic stroke. The presence of extracranial vessel stenosis or occlusion decreases recanalization rates. In patients with intracranial occlusions, higher NIHSS score and ASPECTS and normal vigilance facilitate recanalization. Clinical use of these predictors could influence recanalization strategies in individual patients. © 2014 International Society on Thrombosis and Haemostasis.

  14. Blunt cerebrovascular injury screening with 64-channel multidetector computed tomography: more slices finally cut it.

    PubMed

    Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A

    2014-02-01

    Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.

  15. Prevalence by Computed Tomographic Angiography of Coronary Plaques in South Asian and White Patients With Type 2 Diabetes Mellitus at Low and High Risk Using Four Cardiovascular Risk Scores (UKPDS, FRS, ASCVD, and JBS3).

    PubMed

    Gobardhan, Sanjay N; Dimitriu-Leen, Aukelien C; van Rosendael, Alexander R; van Zwet, Erik W; Roos, Cornelis J; Oemrawsingh, Pranobe V; Kharagjitsingh, Aan V; Jukema, J Wouter; Delgado, Victoria; Schalij, Martin J; Bax, Jeroen J; Scholte, Arthur J H A

    2017-03-01

    The aim of this study was to explore the association between various cardiovascular (CV) risk scores and coronary atherosclerotic burden on coronary computed tomography angiography (CTA) in South Asians with type 2 diabetes mellitus and matched whites. Asymptomatic type 2 diabetic South Asians and whites were matched for age, gender, body mass index, hypertension, and hypercholesterolemia. Ten-year CV risk was estimated using different risk scores (United Kingdom Prospective Diabetes Study [UKPDS], Framingham Risk Score [FRS], AtheroSclerotic CardioVascular Disease [ASCVD], and Joint British Societies for the prevention of CVD [JBS3]) and categorized into low- and high-risk groups. The presence of coronary artery calcium (CAC) and obstructive coronary artery disease (CAD; ≥50% stenosis) was assessed using coronary CTA. Finally, the relation between coronary atherosclerosis on CTA and the low- and high-risk groups was compared. UKPDS, FRS, and ASCVD showed no differences in estimated CV risk between 159 South Asians and 159 matched whites. JBS3 showed a significant greater absolute CV risk in South Asians (18.4% vs 14.2%, p <0.01). Higher presence of CAC score >0 (69% vs 55%, p <0.05) and obstructive CAD (39% vs 27%, p <0.05) was observed in South Asians. South Asians categorized as high risk, using UKPDS, FRS, and ASCVD, showed more CAC and CAD compared than whites. JBS3 showed no differences. In conclusion, asymptomatic South Asians with type 2 diabetes mellitus more frequently showed CAC and obstructive CAD than matched whites in the population categorized as high-risk patients using UKPDS, FRS, and ASCVD as risk estimators. However, JBS3 seems to correlate best to CAC and CAD in both ethnicity groups compared with the other risk scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Dissection and Aneurysm in Patients With Fibromuscular Dysplasia: Findings From the U.S. Registry for FMD.

    PubMed

    Kadian-Dodov, Daniella; Gornik, Heather L; Gu, Xiaokui; Froehlich, James; Bacharach, J Michael; Chi, Yung-Wei; Gray, Bruce H; Jaff, Michael R; Kim, Esther S H; Mace, Pamela; Sharma, Aditya; Kline-Rogers, Eva; White, Christopher; Olin, Jeffrey W

    2016-07-12

    Fibromuscular dysplasia (FMD) is a noninflammatory arterial disease that predominantly affects women. The arterial manifestations may include beading, stenosis, aneurysm, dissection, or tortuosity. This study compared the frequency, location, and outcomes of FMD patients with aneurysm and/or dissection to those of patients without. The U.S. Registry for FMD involves 12 clinical centers. This analysis included clinical history, diagnostic, and therapeutic procedure results for 921 FMD patients enrolled in the registry as of October 17, 2014. Aneurysm occurred in 200 patients (21.7%) and dissection in 237 patients (25.7%); in total, 384 patients (41.7%) had an aneurysm and/or a dissection by the time of FMD diagnosis. The extracranial carotid, renal, and intracranial arteries were the most common sites of aneurysm; dissection most often occurred in the extracranial carotid, vertebral, renal, and coronary arteries. FMD patients with dissection were younger at presentation (48.4 vs. 53.5 years of age, respectively; p < 0.0001) and experienced more neurological symptoms and other end-organ ischemic events than those without dissection. One-third of aneurysm patients (63 of 200) underwent therapeutic intervention for aneurysm repair. Patients with FMD have a high prevalence of aneurysm and/or dissection prior to or at the time of FMD diagnosis. Patients with dissection were more likely to experience ischemic events, and a significant number of patients with dissection or aneurysm underwent therapeutic procedures for these vascular events. Because of the high prevalence and associated morbidity in patients with FMD who have an aneurysm and/or dissection, it is recommended that every patient with FMD undergo one-time cross-sectional imaging from head to pelvis with computed tomographic angiography or magnetic resonance angiography. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. A safe and effective management strategy for blunt cerebrovascular injury: Avoiding unnecessary anticoagulation and eliminating stroke.

    PubMed

    Shahan, Charles P; Magnotti, Louis J; Stickley, Shaun M; Weinberg, Jordan A; Hendrick, Leah E; Uhlmann, Rebecca A; Schroeppel, Thomas J; Hoit, Daniel A; Croce, Martin A; Fabian, Timothy C

    2016-06-01

    Few injuries have produced as much debate with respect to management as have blunt cerebrovascular injuries (BCVIs). Recent work (American Association for the Surgery of Trauma 2013) from our institution suggested that 64-channel multidetector computed tomographic angiography (CTA) could be the primary screening tool for BCVI. Consequently, our screening algorithm changed from digital subtraction angiography (DSA) to CTA, with DSA reserved for definitive diagnosis of BCVI following CTA-positive study results or unexplained neurologic findings. The current study was performed to evaluate outcomes, including the potential for missed clinically significant BCVI, since this new management algorithm was adopted. Patients who underwent DSA (positive CTA finding or unexplained neurologic finding) over an 18-month period subsequent to the previous study were identified. Screening and confirmatory test results, complications, and BCVI-related strokes were reviewed and compared. A total of 228 patients underwent DSA: 64% were male, with mean age and Injury Severity Score (ISS) of 43 years and 22, respectively. A total of 189 patients (83%) had a positive screening CTA result. Of these, DSA confirmed injury in 104 patients (55%); the remaining 85 patients (45%) (false-positive results) were found to have no injury on DSA. Five patients (4.8%) experienced BCVI-related strokes, unchanged from the previous study (3.9%, p = 0.756); two were symptomatic at trauma center presentation, and three occurred while receiving appropriate therapy. No patient with a negative screening CTA result experienced a stroke. This management scheme using 64-channel CTA for screening coupled with DSA for definitive diagnosis was proven to be safe and effective in identifying clinically significant BCVIs and maintaining a low stroke rate. Definitive diagnosis by DSA led to avoidance of potentially harmful anticoagulation in 45% of CTA-positive patients (false-positive results). No strokes resulted from injuries missed by CTA. Diagnostic study, level III.

  18. ACG Clinical Guideline: Management of Patients With Acute Lower Gastrointestinal Bleeding.

    PubMed

    Strate, Lisa L; Gralnek, Ian M

    2016-04-01

    This guideline provides recommendations for the management of patients with acute overt lower gastrointestinal bleeding. Hemodynamic status should be initially assessed with intravascular volume resuscitation started as needed. Risk stratification based on clinical parameters should be performed to help distinguish patients at high- and low-risk of adverse outcomes. Hematochezia associated with hemodynamic instability may be indicative of an upper gastrointestinal (GI) bleeding source and thus warrants an upper endoscopy. In the majority of patients, colonoscopy should be the initial diagnostic procedure and should be performed within 24 h of patient presentation after adequate colon preparation. Endoscopic hemostasis therapy should be provided to patients with high-risk endoscopic stigmata of bleeding including active bleeding, non-bleeding visible vessel, or adherent clot. The endoscopic hemostasis modality used (mechanical, thermal, injection, or combination) is most often guided by the etiology of bleeding, access to the bleeding site, and endoscopist experience with the various hemostasis modalities. Repeat colonoscopy, with endoscopic hemostasis performed if indicated, should be considered for patients with evidence of recurrent bleeding. Radiographic interventions (tagged red blood cell scintigraphy, computed tomographic angiography, and angiography) should be considered in high-risk patients with ongoing bleeding who do not respond adequately to resuscitation and who are unlikely to tolerate bowel preparation and colonoscopy. Strategies to prevent recurrent bleeding should be considered. Nonsteroidal anti-inflammatory drug use should be avoided in patients with a history of acute lower GI bleeding, particularly if secondary to diverticulosis or angioectasia. Patients with established high-risk cardiovascular disease should not stop aspirin therapy (secondary prophylaxis) in the setting of lower GI bleeding. [corrected]. The exact timing depends on the severity of bleeding, perceived adequacy of hemostasis, and the risk of a thromboembolic event. Surgery for the prevention of recurrent lower gastrointestinal bleeding should be individualized, and the source of bleeding should be carefully localized before resection.

  19. An ischemic stroke patient with free floating thrombus in carotid artery, successfully treated by open carotid thrombectomy: a first case report in Nepal.

    PubMed

    Shrestha, Prabin; Adhikari, Rupendra; Tamrakar, Samantha; Pant, Basanta; Koirala, Bhagwan; Yamaguchi, Satoshi; Kurisu, Kaoru

    2012-12-01

    Free floating thrombus in the carotid artery is a well-known phenomenon, though relatively rare. We present a case in which we performed open surgery and achieved successful retrieval of the thrombus. A 40 year-old male patient presented with ischemic stroke and mild left hemiparesis. Computerized tomography and magnetic resonance imaging showed infarction in the right parieto-occipital area. Carotid Doppler study showed carotid stenosis on the right side. Further investigation with CT angiography of the neck vessels confirmed significant carotid artery occlusion with a free-floating thrombus in the internal carotid artery. Carotid endarterectomy was planned under EEG monitoring. The right carotid artery was exposed with a vertical incision along the medial margin of the sternocleido-mastoid muscle. The carotid artery was opened and, as expected, showed a soft, mobile thrombus. Thus thrombectomy was planned. A 2 Fr fogarty catheter was introduced distal to the thrombus, the balloon was inflated and pulled back gently, which removed the thrombus completely. There was no postoperative complication and the patient is fine at 1 year follow-up.

  20. Cerebral angiography

    MedlinePlus

    ... Carotid angiogram; Cervicocerebral catheter-based angiography; Intra-arterial digital subtraction angiography; IADSA ... with the dye are seen. This is called digital subtraction angiography (DSA). After the x-rays are ...

  1. Pedal angiography in peripheral arterial occlusive disease: first-pass i.v. contrast-enhanced MR angiography with blood pool contrast medium versus intraarterial digital subtraction angiography.

    PubMed

    Kos, Sebastian; Reisinger, Clemens; Aschwanden, Markus; Bongartz, Georg M; Jacob, Augustinus L; Bilecen, Deniz

    2009-03-01

    The purpose of this study was to prospectively evaluate first-pass i.v. gadofosveset-enhanced MR angiography in patients with peripheral arterial occlusive disease for visualization of the pedal arteries and stenosis or occlusion of those arteries with intraarterial digital subtraction angiography as the reference standard. Twenty patients with peripheral arterial occlusive disease (nine women, 11 men; age-range 58-83 years) were prospectively enrolled. Gadofosveset first-pass contrast-enhanced MR angiography was performed with a 1.5-T system, a dedicated foot coil, and cuff compression to the calf. Arterial segments were assessed for degree of arterial stenosis, arterial visibility, diagnostic utility, and venous contamination. Detection of vessel stenosis or occlusion was evaluated in comparison with findings at digital subtraction angiography. The unpaired Student's t test was used to test arterial visibility with the two techniques. First-pass MR angiography with gadofosveset had good diagnostic utility in 83.9% of all segments and no venous contamination in 96.8% of all segments. There was no difference between the performance of intraarterial digital subtraction angiography and that of i.v. contrast-enhanced MR angiography in arterial visibility overall (p = 0.245) or in subgroup analysis of surgical arterial bypass targets (p = 0.202). The overall sensitivity, specificity, and accuracy of i.v. gadofosveset-enhanced MR angiography for characterization of clinically significant stenosis and occlusion were 91.4%, 96.1%, and 93.9%. In the subgroup analysis, the sensitivity, specificity, and accuracy were 85.5%, 96.5%, and 92.1%. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with peripheral arterial occlusive disease has arterial visibility equal to that of digital subtraction angiography and facilitates depiction of clinically significant stenosis and occlusion.

  2. Stenosis detection in native hemodialysis fistulas with MDCT angiography.

    PubMed

    Heye, Sam; Maleux, Geert; Claes, Kathleen; Kuypers, Dirk; Oyen, Raymond

    2009-04-01

    The objective of our study was to assess the diagnostic value of 64-MDCT angiography in the evaluation of failing hemodialysis arteriovenous fistulas (AVFs) in comparison with conventional digital subtraction angiography (DSA). Thirty-six patients (22 men; mean age +/- SD, 65 +/- 15 years) with hemodialysis fistula dysfunction underwent MDCT angiography before DSA. Linear weighted kappa was used to calculate interobserver agreement for stenosis for both MDCT angiography and DSA on a 5-point scale. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the detection of >/= 50% stenosis or occlusion on MDCT angiography was calculated using DSA as the standard of reference. Wilcoxon's signed rank test and Mann-Whitney U test were used to compare differences in image quality between MDCT angiography and DSA and between MDCT angiography with the patient's arm stretched overhead or alongside the body, respectively. Interobserver agreement for detecting stenosis was excellent for both DSA (kappa = 0.86; 95% CI, 0.81-0.91) and MDCT angiography (kappa = 0.82; 95% CI, 0.77-0.87). Accuracy, sensitivity, specificity, PPV, and NPV of MDCT angiography for detecting >/= 50% stenosis or occlusion was 92.0% (95% CI, 86.8-95.3%), 90.2% (77.8-96.3%), 92.8% (85.9-96.6%), 85.2% (72.3-92.9%), and 95.4% (89.0-98.3%), respectively. No significant difference in image quality was seen between MDCT angiography and DSA (p = 0.3008) or between MDCT angiography with the patient's arm stretched overhead or alongside the body (p = 0.2912). MDCT angiography is a reproducible and reliable imaging technique for detection of >/= 50% stenosis or occlusion in dysfunctional hemodialysis fistulas.

  3. Role of CT scanning in formation evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergosh, J.L.; Dibona, B.G.

    1988-01-01

    The use of the computerized tomographic (CT) scanner in formation evaluation of difficult to analyze core samples has moved from the research and development phase to daily, routine use in the core-analysis laboratory. The role of the CT scanner has become increasingly important as geologists try to obtain more representative core material for accurate formation evaluation. The most common problem facing the core analyst when preparing to measure petrophysical properties is the selection of representative and unaltered core samples for routine and special core testing. Recent data have shown that heterogeneous reservoir rock can be very difficult, if not impossible,more » to assess correctly when using standard core examination procedures, because many features, such as fractures, are not visible on the core surface. Another problem is the invasion of drilling mud into the core sample. Flushing formation oil and water from the core can greatly alter the saturation and distribution of fluids and lead to serious formation evaluation problems. Because the quality and usefulness of the core date are directly tied to proper sample selection, it has become imperative that the CT scanner be used whenever possible.« less

  4. Chondro-manubrial deformity and bifid rib, rare variations seen in pectus carinatum: a radiological finding.

    PubMed

    Allwyn Joshua, S; Shetty, Lathika; Pare, V S; Sebastian, Roopa

    2013-07-01

    Pectus carinatum or protrusion deformity of chest wall is less frequently occurring anterior chest wall deformity when compared to pectus excavatum. It may be classified as type 1 or chondro-gladiolar and type 2 or chondro-manubrial deformity. Other variations seen are symmetrical and asymmetrical pectus carinatum. Here we present two unique case reports, one with chondro-manubrial deformity (Currarino-Silverman syndrome) and other with asymmetrical pectus carinatum having bifid rib which are some of the rare variations seen in pectus carinatum found during Computerized tomographic examination. Currarino-Silverman syndrome is a type 2 pectus carinatum, a rare deformity with chondro-manubrial involvement and usually associated congenital heart diseases. Early fusion of sternal plates is one of the known theories in producing this deformity. On the other hand, asymmetrical pectus deformity are usually seen due to imbalance or abnormality in growth plates of costal cartilages leading to forked rib or bifid rib, which are accidently seen on radiological examination. To conclude, our reports would help in differential diagnosis from frequently occurring conditions affecting chest like chondro-gladiolar deformity, pectus excavatum, chest wall tumours, rib fractures and intra thoracic ribs.

  5. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  6. Contemporary Patterns of Early Coronary Angiography Use in Patients With Non-ST-Segment Elevation Myocardial Infarction in the United States: Insights From the National Cardiovascular Data Registry Acute Coronary Treatment and Intervention Outcomes Network Registry.

    PubMed

    Malta Hansen, Carolina; Wang, Tracy Y; Chen, Anita Y; Chiswell, Karen; Bhatt, Deepak L; Enriquez, Jonathan R; Henry, Timothy; Roe, Matthew T

    2018-02-26

    The study sought to characterize patient- and hospital-level variation in early angiography use among non-ST-segment elevation myocardial infarction (NSTEMI) patients. Contemporary implementation of guideline recommendations for early angiography use in NSTEMI patients in the United States have not been described. The study analyzed NSTEMI patients included in ACTION (Acute Coronary Treatment and Intervention Outcomes Network) registry (2012 to 2014) who underwent in-hospital angiography. Timing of angiography was categorized as early (≤24 h) vs. delayed (>24 h). The study evaluated factors associated with early angiography, hospital-level variation in early angiography use, and the relationship with quality-of-care measures. A total of 79,760 of 138,688 (57.5%) patients underwent early angiography. Factors most strongly associated with delayed angiography included weekend or holiday presentation, lower initial troponin ratio values, higher initial creatinine values, heart failure on presentation, and older age. Median hospital-level use of early angiography was 58.5% with wide variation across hospitals (21.7% to 100.0%). Patient characteristics did not differ substantially across hospitals grouped by tertiles of early angiography use (low, middle, and high). Hospitals in the highest tertile tended to more commonly use guideline-recommended medications and had higher defect-free care quality scores. In contemporary U.S. practice, high-risk clinical characteristics were associated with lower use of early angiography in NSTEMI patients; hospital-level use of early angiography varied widely despite few differences in case mix. Hospitals that most commonly utilized early angiography also had higher quality-of-care metrics, highlighting the need for improved NSTEMI guideline adherence. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. CT angiography versus conventional digital angiography in preoperative assessment for Chinese living kidney donors.

    PubMed

    Yap, Desmond Yat Hin; Chu, Ferdinand Siu Kay; Chu, Sai Man; Tam, Po Chor; Tam, Sidney; Chan, Tak Mao; Lai, Kar Neng; Tang, Sydney Chi Wai

    2010-01-01

    Computed tomography (CT) angiography is used for preoperative evaluation of living kidney donors, but its correlation with intraoperative findings during the transplant operation remains unknown. Between April 1997 and October 2008, 34 consecutive pairs of living kidney transplants were carried out. Conventional digital angiography was employed for the preoperative assessment in the first 19 pairs, and CT angiography in the subsequent 15 pairs. The radiological reports and operative findings during kidney harvest were carefully examined and compared. Among the 34 cases in our cohort, we found 9 early branching renal arteries (26.4%) and 6 double renal arteries (17%). Venous and ureteral anomalies were rare, with only 1 case (2.9%) of each. CT angiography offered excellent and equal accuracy (accuracy 100%) when compared with conventional digital angiography for renal arterial anatomy. CT angiography showed superior performance compared with conventional angiography in the domain of venous and collecting system anomalies (accuracy 100% vs. 94.7%, respectively). No contrast nephropathy or allergy was documented in our series. CT angiography showed excellent correlations with surgical findings in the Chinese population. It is associated with minimal risk of contrast nephropathy as well as lower cost and therefore should be adopted as the standard preoperative assessment of living kidney donors.

  8. Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

    PubMed

    Chen, Marcus Y; Shanbhag, Sujata M; Arai, Andrew E

    2013-04-01

    To (a) use a new second-generation wide-volume 320-detector row computed tomographic (CT) scanner to explore optimization of radiation exposure in coronary CT angiography in an unselected and consecutive cohort of patients referred for clinical purposes and (b) compare estimated radiation exposure and image quality with that from a cohort of similar patients who underwent imaging with a previous first-generation CT system. The study was approved by the institutional review board, and all subjects provided written consent. Coronary CT angiography was performed in 107 consecutive patients with a new second-generation 320-detector row unit. Estimated radiation exposure and image quality were compared with those from 100 consecutive patients who underwent imaging with a previous first-generation scanner. Effective radiation dose was estimated by multiplying the dose-length product by an effective dose conversion factor of 0.014 mSv/mGy ⋅ cm and reported with size-specific dose estimates (SSDEs). Image quality was evaluated by two independent readers. The mean age of the 107 patients was 55.4 years ± 12.0 (standard deviation); 57 patients (53.3%) were men. The median body mass index was 27.3 kg/m(2) (range, 18.1-47.2 kg/m(2)); however, 71 patients (66.4%) were overweight, obese, or morbidly obese. A tube potential of 100 kV was used in 97 patients (90.6%), single-volume acquisition was used in 104 (97.2%), and prospective electrocardiographic gating was used in 106 (99.1%). The mean heart rate was 57.1 beats per minute ± 11.2 (range, 34-96 beats per minute), which enabled single-heartbeat scans in 100 patients (93.4%). The median radiation dose was 0.93 mSv (interquartile range [IQR], 0.58-1.74 mSv) with the second-generation unit and 2.67 mSv (IQR, 1.68-4.00 mSv) with the first-generation unit (P < .0001). The median SSDE was 6.0 mGy (IQR, 4.1-10.0 mGy) with the second-generation unit and 13.2 mGy (IQR, 10.2-18.6 mGy) with the first-generation unit (P < .0001). Overall, the radiation dose was less than 0.5 mSv for 23 of the 107 CT angiography examinations (21.5%), less than 1 mSv for 58 (54.2%), and less than 4 mSv for 103 (96.3%). All studies were of diagnostic quality, with most having excellent image quality. Three of four image quality indexes were significantly better with the second-generation unit compared with the first-generation unit. The combination of a gantry rotation time of 275 msec, wide volume coverage, iterative reconstruction, automated exposure control, and larger x-ray power generator of the second-generation CT scanner provides excellent image quality over a wide range of body sizes and heart rates at low radiation doses. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122621/-/DC1. RSNA, 2013

  9. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    PubMed

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  10. Gamma Knife surgery for arteriovenous malformations in the brain: integration of time-resolved contrast-enhanced magnetic resonance angiography into dosimetry planning. Technical note.

    PubMed

    Taschner, Christian A; Le Thuc, Vianney; Reyns, Nicolas; Gieseke, Juergen; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2007-10-01

    The aim of this study was to develop an algorithm for the integration of time-resolved contrast-enhanced magnetic resonance (MR) angiography into dosimetry planning for Gamma Knife surgery (GKS) of arteriovenous malformations (AVMs) in the brain. Twelve patients harboring brain AVMs referred for GKS underwent intraarterial digital subtraction (DS) angiography and time-resolved MR angiography while wearing an externally applied cranial stereotactic frame. Time-resolved MR angiography was performed on a 1.5-tesla MR unit (Achieva, Philips Medical Systems) using contrast-enhanced 3D fast field echo sequencing with stochastic central k-space ordering. Postprocessing with interactive data language (Research Systems, Inc.) produced hybrid data sets containing dynamic angiographic information and the MR markers necessary for stereotactic transformation. Image files were sent to the Leksell GammaPlan system (Elekta) for dosimetry planning. Stereotactic transformation of the hybrid data sets containing the time-resolved MR angiography information with automatic detection of the MR markers was possible in all 12 cases. The stereotactic coordinates of vascular structures predefined from time-resolved MR angiography matched with DS angiography data in all cases. In 10 patients dosimetry planning could be performed based on time-resolved MR angiography data. In two patients, time-resolved MR angiography data alone were considered insufficient. The target volumes showed a notable shift of centers between modalities. Integration of time-resolved MR angiography data into the Leksell GammaPlan system for patients with brain AVMs is feasible. The proposed algorithm seems concise and sufficiently robust for clinical application. The quality of the time-resolved MR angiography sequencing needs further improvement.

  11. Use of Noncontrast Computed Tomography and Computed Tomographic Perfusion in Predicting Intracerebral Hemorrhage After Intravenous Alteplase Therapy.

    PubMed

    Batchelor, Connor; Pordeli, Pooneh; d'Esterre, Christopher D; Najm, Mohamed; Al-Ajlan, Fahad S; Boesen, Mari E; McDougall, Connor; Hur, Lisa; Fainardi, Enrico; Shankar, Jai Jai Shiva; Rubiera, Marta; Khaw, Alexander V; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Goyal, Mayank; Lee, Ting-Yim; Aviv, Richard I; Menon, Bijoy K

    2017-06-01

    Intracerebral hemorrhage is a feared complication of intravenous alteplase therapy in patients with acute ischemic stroke. We explore the use of multimodal computed tomography in predicting this complication. All patients were administered intravenous alteplase with/without intra-arterial therapy. An age- and sex-matched case-control design with classic and conditional logistic regression techniques was chosen for analyses. Outcome was parenchymal hemorrhage on 24- to 48-hour imaging. Exposure variables were imaging (noncontrast computed tomography hypoattenuation degree, relative volume of very low cerebral blood volume, relative volume of cerebral blood flow ≤7 mL/min·per 100 g, relative volume of T max ≥16 s with all volumes standardized to z axis coverage, mean permeability surface area product values within T max ≥8 s volume, and mean permeability surface area product values within ipsilesional hemisphere) and clinical variables (NIHSS [National Institutes of Health Stroke Scale], onset to imaging time, baseline systolic blood pressure, blood glucose, serum creatinine, treatment type, and reperfusion status). One-hundred eighteen subjects (22 patients with parenchymal hemorrhage versus 96 without, median baseline NIHSS score of 15) were included in the final analysis. In multivariable regression, noncontrast computed tomography hypoattenuation grade ( P <0.006) and computerized tomography perfusion white matter relative volume of very low cerebral blood volume ( P =0.04) were the only significant variables associated with parenchymal hemorrhage on follow-up imaging (area under the curve, 0.73; 95% confidence interval, 0.63-0.83). Interrater reliability for noncontrast computed tomography hypoattenuation grade was moderate (κ=0.6). Baseline hypoattenuation on noncontrast computed tomography and very low cerebral blood volume on computerized tomography perfusion are associated with development of parenchymal hemorrhage in patients with acute ischemic stroke receiving intravenous alteplase. © 2017 American Heart Association, Inc.

  12. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    PubMed

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure required to obtain clinically useful 3D rotational angiography. © 2018 by American Journal of Neuroradiology.

  13. The evaluation of a formalized queue management system for coronary angiography waiting lists.

    PubMed

    Alter, D A; Newman, Alice M; Cohen, Eric A; Sykora, Kathy; Tu, Jack V

    2005-11-01

    Lengthy waiting lists for coronary angiography have been described in many health care systems worldwide. The extent to which formal queue management systems may improve the prioritization and survival of patients in the angiography queue is unknown. To prospectively evaluate the performance of a formal queue management system for patients awaiting coronary angiography in Ontario. The coronary angiography urgency scale, a formal queue management system developed in 1993 using a modified Delphi panel, allocates recommended maximum waiting times (RMWTs) in accordance with clinical necessity. By using a provincial clinical registry, 35,617 consecutive patients referred into the coronary angiography queue between April 1, 2001, and March 31, 2002, were prospectively tracked. Cox proportional hazards models were used to examined mortality risk across urgency after adjusting for additional clinical and comorbid factors. Good agreement was determined in urgency ratings between scores from the coronary angiography urgency scale and implicit physician judgement, which was obtained independently at the time of the index referral (weighted kappa = 0.49). The overall mortality in the queue was 0.3% (0.47%, 0.26% and 0.13% for urgent, semiurgent and elective patients, respectively). Urgency, as specified by the coronary angiography urgency scale, was the strongest predictor of death in the queue (P<0.001). However, when patients were censored according to their RMWTs, mortality was similar across different levels of urgency. Consequently, up to 18.5 deaths per 10,000 patients could have potentially been averted had patients been triaged and undergone coronary angiography within the RMWT as specified by the coronary angiography urgency scale. The incorporation of the coronary angiography urgency scale as a formal queue management system may decrease mortality in the coronary angiography queue. The authors recommend its implementation in health care systems where patients experience excessive waiting time delays for coronary angiography.

  14. Optical Coherence Tomography Angiography Features of Diabetic Retinopathy

    PubMed Central

    Hwang, Thomas S.; Jia, Yali; Gao, Simon S.; Bailey, Steven T.; Lauer, Andreas K.; Flaxel, Christina J.; Wilson, David J.; Huang, David

    2015-01-01

    Purpose To describe the optical coherence tomography (OCT) angiography features of diabetic retinopathy Methods Using a 70kHz OCT and the split-spectrum amplitude decorrelation angiography (SSADA) algorithm, 6 × 6 mm 3-dimensional angiograms of the macula of 4 patients with diabetic retinopathy were obtained and compared with fluorescein angiography (FA) for features catalogued by the Early Treatment of Diabetic Retinopathy Study. Results OCT angiography detected enlargement and distortion of the foveal avascular zone, retinal capillary dropout, and pruning of arteriolar branches. Areas of capillary loss obscured by fluorescein leakage on FA were more clearly defined on OCT angiography. Some areas of focal leakage on FA that were thought to be microaneurysms were found to be small tufts of neovascularization that extended above the inner limiting membrane. Conclusion OCT angiography does not show leakage, but can better delineate areas of capillary dropout and detect early retinal neovascularization. This new noninvasive angiography technology may be useful for routine surveillance of proliferative and ischemic changes in diabetic retinopathy. PMID:26308529

  15. Laser injury and in vivo multimodal imaging using a mouse model

    NASA Astrophysics Data System (ADS)

    Pocock, Ginger M.; Boretsky, Adam; Gupta, Praveena; Oliver, Jeff W.; Motamedi, Massoud

    2011-03-01

    Balb/c wild type mice were used to perform in vivo experiments of laser-induced thermal damage to the retina. A Heidelberg Spectralis HRA confocal scanning laser ophthalmoscope with a spectral domain optical coherence tomographer was used to obtain fundus and cross-sectional images of laser induced injury in the retina. Sub-threshold, threshold, and supra-threshold lesions were observed using optical coherence tomography (OCT), infrared reflectance, red-free reflectance, fluorescence angiography, and autofluorescence imaging modalities at different time points post-exposure. Lesions observed using all imaging modalities, except autofluorescence, were not visible immediately after exposure but did resolve within an hour and grew in size over a 24 hour period. There was a decrease in fundus autofluorescence at exposure sites immediately following exposure that developed into hyper-fluorescence 24-48 hours later. OCT images revealed threshold damage that was localized to the RPE but extended into the neural retina over a 24 hour period. Volumetric representations of the mouse retina were created to visualize the extent of damage within the retina over a 24 hour period. Multimodal imaging provides complementary information regarding damage mechanisms that may be used to quantify the extent of the damage as well as the effectiveness of treatments without need for histology.

  16. Uncluttered Single-Image Visualization of Vascular Structures using GPU and Integer Programming

    PubMed Central

    Won, Joong-Ho; Jeon, Yongkweon; Rosenberg, Jarrett; Yoon, Sungroh; Rubin, Geoffrey D.; Napel, Sandy

    2013-01-01

    Direct projection of three-dimensional branching structures, such as networks of cables, blood vessels, or neurons onto a 2D image creates the illusion of intersecting structural parts and creates challenges for understanding and communication. We present a method for visualizing such structures, and demonstrate its utility in visualizing the abdominal aorta and its branches, whose tomographic images might be obtained by computed tomography or magnetic resonance angiography, in a single two-dimensional stylistic image, without overlaps among branches. The visualization method, termed uncluttered single-image visualization (USIV), involves optimization of geometry. This paper proposes a novel optimization technique that utilizes an interesting connection of the optimization problem regarding USIV to the protein structure prediction problem. Adopting the integer linear programming-based formulation for the protein structure prediction problem, we tested the proposed technique using 30 visualizations produced from five patient scans with representative anatomical variants in the abdominal aortic vessel tree. The novel technique can exploit commodity-level parallelism, enabling use of general-purpose graphics processing unit (GPGPU) technology that yields a significant speedup. Comparison of the results with the other optimization technique previously reported elsewhere suggests that, in most aspects, the quality of the visualization is comparable to that of the previous one, with a significant gain in the computation time of the algorithm. PMID:22291148

  17. Coronary artery anomalies in Turner Syndrome.

    PubMed

    Viuff, Mette H; Trolle, Christian; Wen, Jan; Jensen, Jesper M; Nørgaard, Bjarne L; Gutmark, Ephraim J; Gutmark-Little, Iris; Mortensen, Kristian H; Gravholt, Claus Højbjerg; Andersen, Niels H

    Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had a tubular origin of the right coronary artery above the aortic sinus. There was no correlation between the presence of coronary arterial anomalies and karyotype, bicuspid aortic valve, or other congenital heart defects. Coronary anomalies are highly prevalent in Turner Syndrome. The left coronary artery is predominantly affected, with an absent left main coronary artery being the most common anomaly. No hemodynamically relevant coronary anomalies were found. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  18. Tomographic Imaging of a Forested Area By Airborne Multi-Baseline P-Band SAR.

    PubMed

    Frey, Othmar; Morsdorf, Felix; Meier, Erich

    2008-09-24

    In recent years, various attempts have been undertaken to obtain information about the structure of forested areas from multi-baseline synthetic aperture radar data. Tomographic processing of such data has been demonstrated for airborne L-band data but the quality of the focused tomographic images is limited by several factors. In particular, the common Fourierbased focusing methods are susceptible to irregular and sparse sampling, two problems, that are unavoidable in case of multi-pass, multi-baseline SAR data acquired by an airborne system. In this paper, a tomographic focusing method based on the time-domain back-projection algorithm is proposed, which maintains the geometric relationship between the original sensor positions and the imaged target and is therefore able to cope with irregular sampling without introducing any approximations with respect to the geometry. The tomographic focusing quality is assessed by analysing the impulse response of simulated point targets and an in-scene corner reflector. And, in particular, several tomographic slices of a volume representing a forested area are given. The respective P-band tomographic data set consisting of eleven flight tracks has been acquired by the airborne E-SAR sensor of the German Aerospace Center (DLR).

  19. Neurosurgical applications of ion beams

    NASA Astrophysics Data System (ADS)

    Fabrikant, Jacob I.; Levy, Richard P.; Phillips, Mark H.; Frankel, Kenneth A.; Lyman, John T.

    1989-04-01

    The program at Donner Pavilion has applied nuclear medicine research to the diagnosis and radiosurgical treatment of life-threatening intracranial vascular disorders that affect more than half a million Americans. Stereotactic heavy-charged-particle Bragg peak radiosurgery, using narrow beams of heavy ions, demonstrates superior biological and physical characteristics in brain over X-and γ-rays, viz., improved dose distribution in the Bragg peak and sharp lateral and distal borders and less scattering of the beam. Examination of CNS tissue response and alteration of cerebral blood-flow dynamics related to heavy-ion Bragg peak radiosurgery is carried out using three-dimensional treatment planning and quantitative imaging utilizing cerebral angiography, computerized tomography (CT), magnetic resonance imaging (MRI), cine-CT, xenon X-ray CT and positron emission tomography (PET). Also under examination are the physical properties of narrow heavy-ion beams for improving methods of dose delivery and dose distribution and for establishing clinical RBE/LET and dose-response relationships for human CNS tissues. Based on the evaluation and treatment with stereotactically directed narrow beams of heavy charged particles of over 300 patients, with cerebral angiography, CT scanning and MRI and PET scanning of selected patients, plus extensive clinical and neuroradiological followup, it appears that Stereotactic charged-particle Bragg peak radiosurgery obliterates intracranial arteriovenous malformations or protects against rebleeding with reduced morbidity and no mortality. Discussion will include the method of evaluation, the clinical research protocol, the Stereotactic neuroradiological preparation, treatment planning, the radiosurgery procedure and the protocol for followup. Emphasis will be placed on the neurological results, including the neuroradiological and clinical response and early and late delayed injury in brain leading to complications (including vasogenic edema, arterial occlusion, venous thrombosis and radiation necrosis). Clinical results in both children and adults will be illustrated and health outcome will be related to the advantages of charged-particle treatment planning, the radiosurgical procedure, dose distribution and dose localization.

  20. [Digital angiography and lipiodol computerized tomography in the anatomopathological framework of hepatocarcinoma].

    PubMed

    Pozzi-Mucelli, R; Pozzi-Mucelli, R; Pagnan, L; Dalla Palma, L

    1994-12-01

    The introduction of therapies other than conventional surgery of hepatocellular carcinoma (HCC) requires an accurate pathologic classification, which is important because it is well known that HCC may have multicentric growth. The Liver Cancer Study Group of Japan has proposed a classification dividing HCCs into three macroscopic forms from the pathologic point of view: nodular, massive and infiltrating HCCs. The nodular type is subdivided into four types: single nodular type, single nodular type with surrounding proliferation, multinodular fused type and multinodular type. Forty-six HCC patients were examined with Lipiodol Computed Tomography (LCT) to investigate the agreement between pathologic and imaging findings. LCT proved to be in close agreement with pathologic findings. Sixteen cases were classified as type I (single nodular type), 8 as type II (single nodular type with limited foci), 1 as type III (multinodular fused type), 18 as type IV (multiple nodular type with diffuse foci) and 3 cases as type V (massive form). No cases of infiltrative forms were observed in our series. Based on LCT findings, the capabilities of digital subtraction angiography (DSA) were studied in the pathologic classification of HCCs. DSA exhibited some limitations in the pathologic classification of HCCs in 5 of 16 patients with type I lesions. In these cases DSA suggested false-positive diagnoses because of regenerative nodules in cirrhotic liver in 3 cases and of daughter nodules (not confirmed at LCT) in 2 cases. In 7 of 8 patients with type II HCCs, DSA failed to show the daughter nodules surrounding the main nodule. In the 18 patients with multiple distant nodules (type IV), DSA was less sensitive in defining nodule number and site. In the massive form, the information obtained with LCT and DSA was comparable. In conclusion, LCT should be considered a basic examination in the study of HCC extent. Based on LCT findings, the most appropriate treatment can be selected, be it surgery, alcohol injection, or intraarterial chemoembolization.

  1. Comparison of CT angiography with conventional arterial angiography in aortoiliac occlusive disease.

    PubMed

    Tins, B; Oxtoby, J; Patel, S

    2001-03-01

    This study compared the results of conventional and CT angiography of the aortoiliac segment in 35 patients with occlusive disease. Disease severity was graded into five categories. Two assessors independently assessed the segment from the distal abdominal aorta to the proximal superficial femoral artery and a consensus was formed. There was interobserver agreement in 87% of segments for conventional angiography and in 78% for CT angiography. Comparison of the two modalities gave identical grading in 84% of segments. Dissimilar grading was found in 16%, with a roughly equal number of undergrading and overgrading. CT angiography has the advantages of being minimally invasive, requiring only an intravenous injection of contrast medium and imaging surrounding soft tissues. Multiplanar reconstruction aids the visualization of asymmetrical stenoses, and collateral blood supply is readily appreciated. However, CT angiography may fail to demonstrate short stenoses owing to limited z-axis resolution.

  2. Diagnostic Accuracy of Computed Tomography Angiography as Compared to Conventional Angiography in Patients Undergoing Noncoronary Cardiac Surgery

    PubMed Central

    Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal

    2016-01-01

    Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455

  3. [Indocyanine green infrared fluorescence angiography and vascular cast--preparation in experimental choroidal circulatory disturbance].

    PubMed

    Matsunaga, H; Andoh, A; Matsubara, T; Fukushima, I; Takahashi, K; Ohkuma, H; Uyama, M

    1996-03-01

    We performed experiments in 20 monkey eyes in order to clarify basic problems about interpretation of indocyanine green fluorescence angiography (ICG angiography). We severed the temporal group of posterior ciliary arteries to produce choroidal circulatory disturbance. ICG angiography was performed immediately, and 2 days, 4 days, and 2 weeks later. Following each ICG angiography, the eye was studied by plastic vascular cast technique with scanning electron microscopy. Immediately after occlusion, ICG angiography showed filling defect in the temporal choroidal hemisphere during the early phase. In the later phase, this area was gradually filled by the dye from choroidal arteries in the nasal hemisphere and the anterior ciliary arteries. Vascular cast preparations showed filling defect in the temporal choroidal hemisphere, corresponding with the early ICG angiogaphic findings. Both filling delay in ICG angiography and filling defect in vascular casts improved daily after occlusion. Two weeks after occlusion, The area of choroidal infarct temporal to the macula turned into chorioretinal atrophy. This area showed hypofluorescence in the early-phase ICG angiography and filling defect of the choriocapillaris in plastic casts. The early-phase ICG angiographic findings thus corresponded well with observations of vascular casts. We conclude that ICG angiography correctly reflects the actual circulatory disturbances in the choroid.

  4. Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deutschmann, Hannes A.; Schoellnast, Helmut; Portugaller, Horst R.

    2006-10-15

    Purpose. To compare the diagnostic accuracy of contrast-enhanced (CE) three-dimensional (3D) moving-table magnetic resonance (MR) angiography with that of selective digital subtraction angiography (DSA) for routine clinical investigation in patients with peripheral arterial occlusive disease. Methods. Thirty-eight patients underwent CE 3D moving-table MR angiography of the pelvic and peripheral arteries. A commercially available large-field-of-view adapter and a dedicated peripheral vascular phased-array coil were used. MR angiograms were evaluated for grade of arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of selective DSA. Results. Two hundred and twenty-six arterial segments inmore » 38 patients were evaluated by both selective DSA and MR angiography. No complications related to MR angiography were observed. There was agreement in stenosis classification in 204 (90.3%) segments; MR angiography overgraded 16 (7%) segments and undergraded 6 (2.7%) segments. Compared with selective DSA, MR angiography provided high sensitivity and specificity and excellent interobserver agreement for detection of severe stenosis (97% and 95%, {kappa} = 0.9 {+-} 0.03) and moderate stenosis (96.5% and 94.3%, {kappa} = 0.9 {+-} 0.03). Conclusion. Compared with selective DSA, moving-table MR angiography proved to be an accurate, noninvasive method for evaluation of peripheral arterial occlusive disease and may thus serve as an alternative to DSA in clinical routine.« less

  5. The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children

    PubMed Central

    Alipour, Mohammad-Reza; Rastegar, Mazyar; Ghaderian, Mehdi; Namayandeh, Seyedeh-Mahdieh; Faraji, Reza; Pezeshkpour, Zohreh

    2016-01-01

    Background Information from pulse oximeter waves confirms the presence of a pulse and helps obtain waves from tissue when the supplying artery is not readily accessible. Objectives This study determined the predictive value of pulse oximeters for detecting improved arterial pulses after angiography. Patients and Methods This cross-sectional, multi-center study included 467 4-day-old to 12-year-old patients and was conducted from January 2012 to January 2016. Angiographies were performed on 12-year-old or younger children for various medical reasons using venous, arterial, or both types of paths. The posterior malleolar or dorsalis pedis were palpated in punctured lower extremities. In the absence of a pulse, pulse oximetry was performed to identify pulse curves at 1 hour, 6 hours, and 12 hours after each angiography. Results Pulse oximetry displayed the pulses of 319 patients immediately following each angiography. Of these, 262 patients had palpable pulses at 6 hours after angiography (P < 0.0001), while 57 patients had no palpable pulse. Of these 57 patients, 15 had no palpable pulse at 12 hours after angiography (P < 0.0001). The odds of pulse improvement in children 6 hours after catheter angiography were 76% for the arterial path, 90% for the venous path, and 83.2% for both paths. At 12 hours after catheter angiography, these values increased to 91.6% for the arterial path, 100% for the venous path, and 95.9% for both paths. Conclusions The pulse oximeter can display the pulse curve immediately (1 hour) after angiography and indicate pulse improvement at 12 hours maximally following an angiography. In this case, heparin alone may be used instead of thrombolytic agents. PMID:28203338

  6. A comparative analysis of noncontrast flow-spoiled versus contrast-enhanced magnetic resonance angiography for evaluation of peripheral arterial disease.

    PubMed

    Kassamali, Rahil Hussein; Hoey, Edward T D; Ganeshan, Arul; Littlehales, Tracey

    2013-01-01

    This feasibility study aimed to obtain initial data to assess the performance of a novel noncontrast spoiled magnetic resonance (MR) angiography technique (fresh-blood imaging [FBI]) compared to gadolinium-enhanced MR (Gd-MR) angiography for evaluation of the aorto-iliac and lower extremity arteries. Thirteen patients with suspected lower extremity arterial disease that had undergone Gd-MR angiography and FBI at the same session were randomly included in the study. FBI was performed using an ECG-gated ow-spoiled T2-weighted half-Fourier fast spin-echo sequence. For analysis, the aortoiliac and lower limb arteries were divided into 18 anatomical segments. Two blinded readers individually graded image quality of FBI and also assessed the presence and severity of any stenotic lesions. A similar analysis was performed for the Gd-MR angiography images. A total of 385 arterial segments were analyzed; 34 segments were excluded due to degraded image quality (1.3% of Gd- MR vs. 8% of FBI-MR angiography images). FBI-MR angiography had comparable accuracy to Gd-MR angiography for assessment of the above knee vessels with high kappa statistics (large arteries, 0.91; small arteries, 0.86) and high sensitivity (large arteries, 98.1%; small arteries, 88.6%) and specificity (large arteries, 97.2%; small arteries, 97.6%) using Gd-MR angiography as the gold standard. Initial results show good agreement between FBI-MR angiography and Gd-MR angiography in the diagnosis of peripheral arterial disease, making FBI a potential alternative in patients with renal impairment. FBI showed highest accuracy in the above knee vessels. Technological refinements are required to improve accuracy for assessing the calf and pedal vessels.

  7. Angiography Before Posterior Mediastinal Tumor Resection: Selection Criteria and Patient Outcomes.

    PubMed

    Madariaga, Maria Lucia; Borges, Lawrence F; Rabinov, James D; Chang, David C; Lanuti, Michael; Mathisen, Douglas J; Gaissert, Henning A

    2018-04-01

    Resection of posterior mediastinal tumors may be complicated by bleeding or neurologic injury. Preoperative spinal angiography of mediastinal tumors has been underreported or not commonly practiced. This study evaluated the selection criteria and outcomes of patients with posterior mediastinal tumors who underwent preoperative angiography and embolization. This was a single-institution retrospective study of patients with posterior mediastinal tumors from 2002 to 2016. Multilevel spinal angiography was performed, with or without selective arterial embolization of vascular supply, in patients selected by thoracic or neurologic surgeons. Ten of 87 patients (11%) with posterior mediastinal tumors underwent preoperative angiography. A mean of 11 arteries (range, 2 to 25) were studied. Embolization in 7 of 10 patients successfully occluded 1 to 3 arteries. There was no significant difference in age, sex, body mass index, American Society of Anesthesiologists Physical Status Classification, operative time, operative blood loss, complications, or death between patients with or without angiography. Patients who underwent angiography had larger tumors (1,490 vs 97 cm 3 , p < 0.0001), involvement of the neuroforamen (44% vs 10%, p < 0.05), and a longer hospital stay (9 vs 4.5 days, p < 0.05). Angiography was complicated in 1 patient by vocal cord ulceration after intubation of a tumor-compressed trachea. Shared blood supply between the tumor and the spinal cord precluded embolization and tumor resection in 1 patient. Use of angiography increased over time. Selective preoperative angiography for evaluation of posterior mediastinal tumors identifies arterial variations, threatened spinal arteries, and targets for embolization. The specific role of angiography and embolization requires further investigation to standardize indications and protocols for the number of arteries examined. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Quality of life after acute myocardial infarction among patients treated at sites with and without on-site availability of angiography.

    PubMed

    Pilote, Louise; Lauzon, Claude; Huynh, Thao; Dion, Danielle; Roux, René; Racine, Normand; Carignan, Suzanne; Diodati, Jean G; Lévesque, Claude; Charbonneau, François; Pouliot, Joël; Joseph, Lawrence; Eisenberg, Mark J

    2002-03-11

    Previous studies have compared the treatment and outcome of patients with acute myocardial infarction (AMI) admitted at sites with and without availability of angiography. Although mortality rates do not differ, it is unknown if quality of life (QOL) and functional status differ. We measured QOL and functional status in patients with AMI treated within Québec at 5 sites with (n = 253) and 5 sites without (n = 334) angiography. At admission, clinical characteristics, complication rates, and baseline measures of QOL and functional status were similar at sites with and without angiography. During hospitalization, patients treated at sites with angiography were more likely to undergo an invasive cardiac procedure than patients admitted at sites without angiography (angiography, 63% vs 26%; percutaneous transluminal coronary angioplasty, 33% vs 13%; and coronary artery bypass graft, 12% vs 5%). At 30 days and 6 months after AMI, QOL was slightly superior at sites with angiography, but by 1 year, most measures of QOL were back to baseline at both types of sites and were similar between the 2 groups. At 6 months, most standard health-related QOL components were similar; only physical and emotional role limitations were higher at sites with angiography. Return to work occurred earlier (at 30 days, 23% vs 12%), and a lower proportion of patients was readmitted for angina (within 1 year after AMI, 12% vs 18%) at sites with angiography. In the early post-AMI period, the QOL of patients admitted at sites with angiography was higher than that of patients admitted at sites without angiography. However, by 1 year, the QOL and functional status of patients was similar in both groups. Differences in QOL were greatest when differences in treatment were greatest, lending support to a positive albeit small association between an early invasive approach to post-AMI care and improved QOL.

  9. Three-dimensional volume-rendering technique in the angiographic follow-up of intracranial aneurysms embolized with coils.

    PubMed

    Zhou, Bing; Li, Ming-Hua; Wang, Wu; Xu, Hao-Wen; Cheng, Yong-De; Wang, Jue

    2010-03-01

    The authors conducted a study to evaluate the advantages of a 3D volume-rendering technique (VRT) in follow-up digital subtraction (DS) angiography of coil-embolized intracranial aneurysms. One hundred nine patients with 121 intracranial aneurysms underwent endovascular coil embolization and at least 1 follow-up DS angiography session at the authors' institution. Two neuroradiologists independently evaluated the conventional 2D DS angiograms, rotational angiograms, and 3D VRT images obtained at the interventional procedures and DS angiography follow-up. If multiple follow-up sessions were performed, the final follow-up was mainly considered. The authors compared the 3 techniques for their ability to detect aneurysm remnants (including aneurysm neck and sac remnants) and parent artery stenosis based on the angiographic follow-up. The Kruskal-Wallis test was used for group comparisons, and the kappa test was used to measure interobserver agreement. Statistical analyses were performed using commercially available software. There was a high statistical significance among 2D DS angiography, rotational angiography, and 3D VRT results (X(2) = 9.9613, p = 0.0069) when detecting an aneurysm remnant. Further comparisons disclosed a statistical significance between 3D VRT and rotational angiography (X(2) = 4.9754, p = 0.0257); a high statistical significance between 3D VRT and 2D DS angiography (X(2) = 8.9169, p = 0.0028); and no significant difference between rotational angiography and 2D DS angiography (X(2) = 0.5648, p = 0.4523). There was no statistical significance among the 3 techniques when detecting parent artery stenosis (X(2) = 2.5164, p = 0.2842). One case, in which parent artery stenosis was diagnosed by 2D DS angiography and rotational angiography, was excluded by 3D VRT following observations of multiple views. The kappa test showed good agreement between the 2 observers. The 3D VRT is more sensitive in detecting aneurysm remnants than 2D DS angiography and rotational angiography and is helpful for identifying parent artery stenosis. The authors recommend this technique for the angiographic follow-up of patients with coil-embolized aneurysms.

  10. Does CT Angiography Matter for Patients with Cervical Spine Injuries?

    PubMed

    Hagedorn, John C; Emery, Sanford E; France, John C; Daffner, Scott D

    2014-06-04

    Cervical injury can be associated with vertebral artery injury. This study was performed to determine the impact of computed tomography (CT) angiography of the head and neck on planning treatment of cervical spine fracture, if these tests were ordered appropriately, and to estimate cost and associated exposure to radiation and contrast medium. This retrospective review included all patients who underwent CT of the cervical spine and CT angiography of the head and neck from January 2010 to August 2011 at one institution. Patients were divided into those with and those without cervical spine fracture seen on CT of the cervical spine. We determined if the CT angiography of the head and neck was positive for vascular injury in the patients with a cervical fracture. Vascular injury treatment and alterations in surgical fracture treatment due to positive CT angiography of the head and neck were recorded. A scan was deemed appropriate if it had been ordered per established institutional protocol. Of the 381 patients who underwent CT angiography of the head and neck, 126 had a cervical injury. Sixteen of the CT angiography studies were appropriately ordered for non-spinal indications, and twenty-three were inappropriately ordered. The CT angiography was positive for one patient for whom the imaging was off protocol and one for whom the indication was non-spinal. Nineteen patients had positive CT angiography of the head and neck; no patient underwent surgical intervention for a vascular lesion. Eleven patients underwent surgical intervention for a cervical fracture; the operative plan was changed because of vascular injury in one case. The CT angiography was positive for eleven of forty-eight patients who had sustained a C2 fracture; this group accounted for eleven of the nineteen positive CT angiography studies. Noncontiguous injuries occurred in nineteen patients; three had positive CT angiography of the head and neck. The approximate charge for the CT angiography was $3925, radiation exposure was approximately 4000 mGy/cm, and contrast-medium load was approximately 100 mL. Positive CT angiography of the head and neck rarely altered surgical treatment of cervical spine injuries. This study supports the findings in the literature that C1-C3 spine injuries have an increased association with vertebral artery injury. CT angiography of the head and neck ordered off protocol had a low likelihood of being positive. Strict adherence to protocols for CT angiography of the head and neck can reduce costs and decrease unnecessary exposure to radiation and contrast medium. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  11. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abraham, I., E-mail: isabelle.abraham@cea.fr; Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  12. Use of Order Sets in Inpatient Computerized Provider Order Entry Systems: A Comparative Analysis of Usage Patterns at Seven Sites

    PubMed Central

    Wright, Adam; Feblowitz, Joshua C.; Pang, Justine E.; Carpenter, James D.; Krall, Michael A.; Middleton, Blackford; Sittig, Dean F.

    2012-01-01

    Background Many computerized provider order entry (CPOE) systems include the ability to create electronic order sets: collections of clinically-related orders grouped by purpose. Order sets promise to make CPOE systems more efficient, improve care quality and increase adherence to evidence-based guidelines. However, the development and implementation of order sets can be expensive and time-consuming and limited literature exists about their utilization. Methods Based on analysis of order set usage logs from a diverse purposive sample of seven sites with commercially- and internally-developed inpatient CPOE systems, we developed an original order set classification system. Order sets were categorized across seven non-mutually exclusive axes: admission/discharge/transfer (ADT), perioperative, condition-specific, task-specific, service-specific, convenience, and personal. In addition, 731 unique subtypes were identified within five axes: four in ADT (S=4), three in perioperative, 144 in condition-specific, 513 in task-specific, and 67 in service-specific. Results Order sets (n=1,914) were used a total of 676,142 times at the participating sites during a one-year period. ADT and perioperative order sets accounted for 27.6% and 24.2% of usage respectively. Peripartum/labor, chest pain/Acute Coronary Syndrome/Myocardial Infarction and diabetes order sets accounted for 51.6% of condition-specific usage. Insulin, angiography/angioplasty and arthroplasty order sets accounted for 19.4% of task-specific usage. Emergency/trauma, Obstetrics/Gynecology/Labor Delivery and anesthesia accounted for 32.4% of service-specific usage. Overall, the top 20% of order sets accounted for 90.1% of all usage. Additional salient patterns are identified and described. Conclusion We observed recurrent patterns in order set usage across multiple sites as well as meaningful variations between sites. Vendors and institutional developers should identify high-value order set types through concrete data analysis in order to optimize the resources devoted to development and implementation. PMID:22819199

  13. Feasibility and utility of an integrated medical imaging and informatics smartphone system for management of acute stroke.

    PubMed

    Shkirkova, Kristina; Akam, Eftitan Y; Huang, Josephine; Sheth, Sunil A; Nour, May; Liang, Conrad W; McManus, Michael; Trinh, Van; Duckwiler, Gary; Tarpley, Jason; Vinuela, Fernando; Saver, Jeffrey L

    2017-12-01

    Background Rapid dissemination and coordination of clinical and imaging data among multidisciplinary team members are essential for optimal acute stroke care. Aim To characterize the feasibility and utility of the Synapse Emergency Room mobile (Synapse ERm) informatics system. Methods We implemented the Synapse ERm system for integration of clinical data, computerized tomography, magnetic resonance, and catheter angiographic imaging, and real-time stroke team communications, in consecutive acute neurovascular patients at a Comprehensive Stroke Center. Results From May 2014 to October 2014, the Synapse ERm application was used by 33 stroke team members in 84 Code Stroke alerts. Patient age was 69.6 (±17.1), with 41.5% female. Final diagnosis was: ischemic stroke 64.6%, transient ischemic attack 7.3%, intracerebral hemorrhage 6.1%, and cerebrovascular-mimic 22.0%. Each patient Synapse ERm record was viewed by a median of 10 (interquartile range 6-18) times by a median of 3 (interquartile range 2-4) team members. The most used feature was computerized tomography, magnetic resonance, and catheter angiography image display. In-app tweet team, communications were sent by median 1 (interquartile range 0-1, range 0-13) users per case and viewed by median 1 (interquartile range 0-3, range 0-44) team members. Use of the system was associated with rapid treatment times, faster than national guidelines, including median door-to-needle 51.0 min (interquartile range 40.5-69.5) and median door-to-groin 94.5 min (interquartile range 85.5-121.3). In user surveys, the mobile information platform was judged easy to employ in 91% (95% confidence interval 65%-99%) of uses and of added help in stroke management in 50% (95% confidence interval 22%-78%). Conclusion The Synapse ERm mobile platform for stroke team distribution and integration of clinical and imaging data was feasible to implement, showed high ease of use, and moderate perceived added utility in therapeutic management.

  14. Feasibility of Selective Catheter-Directed Coronary Computed Tomography Angiography Using Ultralow-Dose Intracoronary Contrast Injection in a Swine Model.

    PubMed

    Hong, Youngtaek; Shin, Sanghoon; Park, Hyung-Bok; Lee, Byoung Kwon; Arsanjani, Reza; ó Hartaigh, Bríain; Ha, Seongmin; Jang, Yeonggul; Jeon, Byunghwan; Jung, Sunghee; Park, Se-Il; Sung, Ji Min; Shim, Hackjoon; Chang, Hyuk-Jae

    2015-07-01

    Selective catheter-directed intracoronary contrast injected coronary computed tomography angiography (selective CCTA) has recently been introduced for on-site evaluation of coronary artery disease during coronary artery catheterization. In this study, we aimed to develop a feasible protocol for selective CCTA using ultralow-dose contrast medium as compared with conventional intravenous CCTA (IV CCTA). A novel combined system incorporating coronary angiography and a 320-detector row computed tomographic scanner was used to study 4 swine (35-40 kg) under animal institutional review board approval. A selective CCTA scan was simultaneously performed with an injection of 13.13 mgI/mL of modulated contrast medium at multiple different injection rates including 2, 3, and 4 mL/s and different total injection volumes of either 20 or 30 mL. Intravenous CCTA was performed with 60 mL of contrast medium, followed by 30 mL of saline chaser at 5 mL/s. Coronary mean and peak intensity, transluminal attenuation gradient, as well as 3-dimensional maximum intensity projections were obtained. Attenuation values (mean ± standard error, in Hounsfield units [HUs]) of selective CCTA for the left anterior descending (LAD) and right coronary artery (RCA) using the various combinations of injection rates and total injection volumes were as follows: 20 mL at 2 mL/s (LAD, 270.3 ± 20.4 HU; RCA, 322.6 ± 7.4 HU), 20 mL at 3 mL/s (LAD, 262.9 ± 20.4 HU; RCA, 264.7 ± 7.4 HU), 30 mL at 3 mL/s (LAD, 276.8 ± 20.4 HU; RCA, 274.0 ± 7.4 HU), 20 mL at 4 mL/s (LAD, 268.0 ± 20.4 HU; RCA, 277.7 ± 7.4 HU), and 30 mL at 4 mL/s (LAD, 251.3 ± 20.4 HU; RCA, 334.7 ± 7.4 HU). The representative protocol of the selective CCTA studies produced results within the optimal enhancement range (approximately 250-350 HU) for all segments, and comparison of transluminal attenuation gradient data with selective CCTA and IV CCTA studies demonstrated that the former method was more homogenous (-1.5245 and -1.7558 for LAD as well as 0.0459 and 0.0799 for RCA, respectively). Notably, the volume of iodine contrast medium used for selective CCTA was reported to be 1.09% (0.2 g) of IV CCTA (24 g). The current findings demonstrate the feasibility of selective CCTA using ultralow-dose intracoronary contrast injection. This technique may provide additional means of coronary evaluation in patients who may require strategic planning before a procedure using a combined modality system.

  15. Efficacy and safety of gadobutrol-enhanced MRA of the renal arteries: Results from GRAMS (Gadobutrol-enhanced renal artery MRA study), a prospective, intraindividual multicenter phase 3 blinded study.

    PubMed

    Fabrega-Foster, Kelly E; Agarwal, Sheela; Rastegar, Neda; Haverstock, Daniel; Agris, Jacob M; Kamel, Ihab R

    2018-02-01

    To compare the performance of magnetic resonance angiography (MRA) with 1M gadobutrol, a high relaxivity macrocyclic contrast agent, to 2D time-of-flight MRA (ToF-MRA) using computed tomographic angiography (CTA) as the standard of reference. Primary objectives were evaluation for superiority of structural delineation and noninferiority for detection and exclusion of clinically significant disease. In all, 315 subjects underwent unenhanced and contrast-enhanced MRA with 1M gadobutrol (CE-MRA) and were scanned with 1.5T MRI equipped with an at least 6-element body coil. Evaluations were based on both centralized blinded read (BR) performed by six readers as well as investigator site interpretations for the 292 subjects who completed the study. Quantitative evaluations including percent stenosis and normal vessel measurements were also performed. Secondary endpoints included identification of accessory renal arteries, diagnosis of fibromuscular dysplasia (FMD), diagnostic confidence, and need for additional imaging. A total of 292 patients suspected of renal artery disease completed the study. CE-MRA demonstrated statistically significant improvement in assessability of vascular segments compared to ToF: 95.9% vs. 77.6% (P < 0.0001). In the BR, the sensitivity and specificity of CE-MRA were noninferior to ToF-MRA (53.4% vs. 46.6% and 95.1% vs. 85.7%, respectively). There was less error in the CE-MRA stenosis measurements (0.15 mm gadobutrol vs. 0.41 mm ToF, P < 0.05). FMD was correctly diagnosed more frequently, 10% more accessory renal arteries were identified (P < 0.01), diagnostic confidence increased (P < 0.01), and fewer additional imaging studies were recommended (P < 0.01). Gadobutrol-enhanced MRA of the renal arteries has superior visualization, more accurate vessel measurements, and may serve as a CTA alternative without any ionizing radiation. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:572-581. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Current but not past smoking increases the risk of cardiac events: insights from coronary computed tomographic angiography

    PubMed Central

    Nakanishi, Rine; Berman, Daniel S.; Budoff, Matthew J.; Gransar, Heidi; Achenbach, Stephan; Al-Mallah, Mouaz; Andreini, Daniele; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Cheng, Victor Y.; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; Cury, Ricardo; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Jörg; Feuchtner, Gudrun; Kim, Yong-Jin; Kaufmann, Philipp A.; Leipsic, Jonathon; Lin, Fay Y.; Maffei, Erica; Pontone, Gianluca; Raff, Gilbert; Shaw, Leslee J.; Villines, Todd C.; Dunning, Allison; Min, James K.

    2015-01-01

    Aims We evaluated coronary artery disease (CAD) extent, severity, and major adverse cardiac events (MACEs) in never, past, and current smokers undergoing coronary CT angiography (CCTA). Methods and results We evaluated 9456 patients (57.1 ± 12.3 years, 55.5% male) without known CAD (1588 current smokers; 2183 past smokers who quit ≥3 months before CCTA; and 5685 never smokers). By risk-adjusted Cox proportional-hazards models, we related smoking status to MACE (all-cause death or non-fatal myocardial infarction). We further performed 1:1:1 propensity matching for 1000 in each group evaluate event risk among individuals with similar age, gender, CAD risk factors, and symptom presentation. During a mean follow-up of 2.8 ± 1.9 years, 297 MACE occurred. Compared with never smokers, current and past smokers had greater atherosclerotic burden including extent of plaque defined as segments with any plaque (2.1 ± 2.8 vs. 2.6 ± 3.2 vs. 3.1 ± 3.3, P < 0.0001) and prevalence of obstructive CAD [1-vessel disease (VD): 10.6% vs. 14.9% vs. 15.2%, P < 0.001; 2-VD: 4.4% vs. 6.1% vs. 6.2%, P = 0.001; 3-VD: 3.1% vs. 5.2% vs. 4.3%, P < 0.001]. Compared with never smokers, current smokers experienced higher MACE risk [hazard ratio (HR) 1.9, 95% confidence interval (CI) 1.4–2.6, P < 0.001], while past smokers did not (HR 1.2, 95% CI 0.8–1.6, P = 0.35). Among matched individuals, current smokers had higher MACE risk (HR 2.6, 95% CI 1.6–4.2, P < 0.001), while past smokers did not (HR 1.3, 95% CI 0.7–2.4, P = 0.39). Similar findings were observed for risk of all-cause death. Conclusion Among patients without known CAD undergoing CCTA, current and past smokers had increased burden of atherosclerosis compared with never smokers; however, risk of MACE was heightened only in current smokers. PMID:25666322

  17. Sex-based Prognostic Implications of Nonobstructive Coronary Artery Disease: Results from the International Multicenter CONFIRM Study

    PubMed Central

    Taylor, Carolyn M.; Gransar, Heidi; Shaw, Leslee J.; Ahmadi, Amir; Thompson, Angus; Humphries, Karin; Berman, Daniel S.; Hausleiter, Jörg; Achenbach, Stephan; Al-Mallah, Mouaz; Budoff, Matthew J.; Cademartiri, Fillippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Chow, Benjamin J. W.; Cury, Ricardo C.; Delago, Augustin J.; Dunning, Allison L.; Feuchtner, Gudrun M.; Hadamitzky, Martin; Kaufmann, Philipp A.; Lin, Fay Y.; Chinnaiyan, Kavitha M.; Maffei, Erica; Raff, Gilbert L.; Villines, Todd C.; Gomez, Millie J.; Min, James K.

    2014-01-01

    Purpose To determine the clinical outcomes of women and men with nonobstructive coronary artery disease (CADcoronary artery disease) with coronary computed tomographic (CT) angiography data in patients who were similar in terms of CADcoronary artery disease risk factors, angina typicality, and CADcoronary artery disease extent and distribution. Materials and Methods Institutional review board approval was obtained for all participating sites, with either informed consent or waiver of informed consent. In a prospective international multicenter cohort study of 27 125 patients undergoing coronary CT angiography at 12 centers, 18 158 patients with no CADcoronary artery disease or nonobstructive (<50% stenosis) CADcoronary artery disease were examined. Men and women were propensity matched for age, CADcoronary artery disease risk factors, angina typicality, and CADcoronary artery disease extent and distribution, which resulted in a final cohort of 11 462 subjects. Nonobstructive CADcoronary artery disease presence and extent were related to incident major adverse cardiovascular events (MACEmajor adverse cardiovascular events), which were inclusive of death and myocardial infarction and were estimated by using multivariable Cox proportional hazards models. Results At a mean follow-up ± standard deviation of 2.3 years ± 1.1, MACEmajor adverse cardiovascular events occurred in 164 patients (0.6% annual event rate). After matching, women and men experienced identical annualized rates of myocardial infarction (0.2% vs 0.2%, P = .72), death (0.5% vs 0.5%, P = .98), and MACEmajor adverse cardiovascular events (0.6% vs 0.6%, P = .94). In multivariable analysis, nonobstructive CADcoronary artery disease was associated with similarly increased MACEmajor adverse cardiovascular events for both women (hazard ratio: 1.96 [95% confidence interval {CIconfidence interval}: 1.17, 3.28], P = .01) and men (hazard ratio: 1.77 [95% CIconfidence interval: 1.07, 2.93], P = .03). Conclusion When matched for age, CADcoronary artery disease risk factors, angina typicality, and nonobstructive CADcoronary artery disease extent, women and men experience comparable rates of incident mortality and myocardial infarction. © RSNA, 2014 Online supplemental material is available for this article. PMID:25028784

  18. Sex-based prognostic implications of nonobstructive coronary artery disease: results from the international multicenter CONFIRM study.

    PubMed

    Leipsic, Jonathon; Taylor, Carolyn M; Gransar, Heidi; Shaw, Leslee J; Ahmadi, Amir; Thompson, Angus; Humphries, Karin; Berman, Daniel S; Hausleiter, Jörg; Achenbach, Stephan; Al-Mallah, Mouaz; Budoff, Matthew J; Cademartiri, Fillippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chow, Benjamin J W; Cury, Ricardo C; Delago, Augustin J; Dunning, Allison L; Feuchtner, Gudrun M; Hadamitzky, Martin; Kaufmann, Philipp A; Lin, Fay Y; Chinnaiyan, Kavitha M; Maffei, Erica; Raff, Gilbert L; Villines, Todd C; Gomez, Millie J; Min, James K

    2014-11-01

    To determine the clinical outcomes of women and men with nonobstructive coronary artery disease ( CAD coronary artery disease ) with coronary computed tomographic (CT) angiography data in patients who were similar in terms of CAD coronary artery disease risk factors, angina typicality, and CAD coronary artery disease extent and distribution. Institutional review board approval was obtained for all participating sites, with either informed consent or waiver of informed consent. In a prospective international multicenter cohort study of 27 125 patients undergoing coronary CT angiography at 12 centers, 18 158 patients with no CAD coronary artery disease or nonobstructive (<50% stenosis) CAD coronary artery disease were examined. Men and women were propensity matched for age, CAD coronary artery disease risk factors, angina typicality, and CAD coronary artery disease extent and distribution, which resulted in a final cohort of 11 462 subjects. Nonobstructive CAD coronary artery disease presence and extent were related to incident major adverse cardiovascular events ( MACE major adverse cardiovascular events ), which were inclusive of death and myocardial infarction and were estimated by using multivariable Cox proportional hazards models. At a mean follow-up ± standard deviation of 2.3 years ± 1.1, MACE major adverse cardiovascular events occurred in 164 patients (0.6% annual event rate). After matching, women and men experienced identical annualized rates of myocardial infarction (0.2% vs 0.2%, P = .72), death (0.5% vs 0.5%, P = .98), and MACE major adverse cardiovascular events (0.6% vs 0.6%, P = .94). In multivariable analysis, nonobstructive CAD coronary artery disease was associated with similarly increased MACE major adverse cardiovascular events for both women (hazard ratio: 1.96 [95% confidence interval { CI confidence interval }: 1.17, 3.28], P = .01) and men (hazard ratio: 1.77 [95% CI confidence interval : 1.07, 2.93], P = .03). When matched for age, CAD coronary artery disease risk factors, angina typicality, and nonobstructive CAD coronary artery disease extent, women and men experience comparable rates of incident mortality and myocardial infarction.

  19. Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite.

    PubMed

    Uhl, Eberhard; Zausinger, Stefan; Morhard, Dominik; Heigl, Thomas; Scheder, Benjamin; Rachinger, Walter; Schichor, Christian; Tonn, Jörg-Christian

    2009-05-01

    We report our preliminary experience in a prospective series of patients with regard to feasibility, work flow, and image quality using a multislice computed tomographic (CT) scanner combined with a frameless neuronavigation system (NNS). A sliding gantry 40-slice CT scanner was installed in a preexisting operating room. The scanner was connected to a frameless infrared-based NNS. Image data was transferred directly from the scanner into the navigation system. This allowed updating of the NNS during surgery by automated image registration based on the position of the gantry. Intraoperative CT angiography was possible. The patient was positioned on a radiolucent operating table that fits within the bore of the gantry. During image acquisition, the gantry moved over the patient. This table allowed all positions and movements like any normal operating table without compromising the positioning of the patient. For cranial surgery, a carbon-made radiolucent head clamp was fixed to the table. Experience with the first 230 patients confirms the feasibility of intraoperative CT scanning (136 patients with intracranial pathology, 94 patients with spinal lesions). After a specific work flow, interruption of surgery for intraoperative scanning can be limited to 10 to 15 minutes in cranial surgery and to 9 minutes in spinal surgery. Intraoperative imaging changed the course of surgery in 16 of the 230 cases either because control CT scans showed suboptimal screw position (17 of 307 screws, with 9 in 7 patients requiring correction) or that tumor resection was insufficient (9 cases). Intraoperative CT angiography has been performed in 7 cases so far with good image quality to determine residual flow in an aneurysm. Image quality was excellent in spinal and cranial base surgery. The system can be installed in a preexisting operating environment without the need for special surgical instruments. It increases the safety of the patient and the surgeon without necessitating a change in the existing surgical protocol and work flow. Imaging and updating of the NNS can be performed at any time during surgery with very limited time and modification of the surgical setup. Multidisciplinary use increases utilization of the system and thus improves the cost-efficiency relationship.

  20. Sex Differences in Functional Stress Test Versus CT Angiography in Symptomatic Patients With Suspected CAD: Insights From PROMISE

    PubMed Central

    Pagidipati, Neha J.; Hemal, Kshipra; Coles, Adrian; Mark, Daniel B.; Dolor, Rowena J.; Pellikka, Patricia A.; Hoffmann, Udo; Litwin, Sheldon E.; Udelson, James; Daubert, Melissa A.; Shah, Svati H.; Martinez, Beth; Lee, Kerry L.; Douglas, Pamela S.

    2016-01-01

    Background Risk stratification is an important goal of cardiac noninvasive tests (NITs), yet little contemporary data exist on the prognostic value of different NITs by patient sex. Objectives To compare the results and prognostic information derived from anatomic versus stress testing in stable men and women with suspected coronary artery disease. Methods In 8966 PROMISE trial patients tested as randomized (4500 computed tomographic angiography [CTA], 52% female; 4466 stress testing, 53% female), we assessed the relationship between sex and NIT results using logistic regression, and the relationship between sex and a composite of death, myocardial infarction, and unstable angina hospitalization using Cox proportional hazards models. Results In women, a positive CTA (≥70% stenosis) was less likely than a positive stress test (8% vs. 12%, adjusted OR 0.67 [95% CI 0.55-0.82]). Compared with negative tests, a positive CTA was more strongly associated with subsequent clinical events than a positive stress test (CTA adjusted HR 5.86 [95% CI 3.32-10.35]; stress adjusted HR 2.27 [95% CI 1.21-4.25]; adjusted p=0.028). Men were more likely to have a positive CTA than stress test (16% vs. 14%, adjusted OR 1.23 [95% CI 1.04-1.47]). Compared with negative tests, a positive CTA was less strongly associated with subsequent clinical events than a positive stress test in men, although this difference was not statistically significant (CTA adjusted HR 2.80 [95% CI 1.76-4.45]; stress adjusted HR 4.42 [95% CI 2.77-7.07]; adjusted p=0.168). Negative CTA and stress tests were equally likely to predict an event in both sexes (adjusted p-values=NS). A significant interaction between sex, NIT type, and test result (p=0.01) suggests that sex and NIT type jointly influence the relationship between test result and clinical events. Conclusions The prognostic value of an NIT result varies by test type and patient sex. Women appear to derive more prognostic information from a CTA, while men tend to derive similar prognostic value from both test types. PMID:27058908

  1. Fully quantitative pixel-wise analysis of cardiovascular magnetic resonance perfusion improves discrimination of dark rim artifact from perfusion defects associated with epicardial coronary stenosis.

    PubMed

    Ta, Allison D; Hsu, Li-Yueh; Conn, Hannah M; Winkler, Susanne; Greve, Anders M; Shanbhag, Sujata M; Chen, Marcus Y; Patricia Bandettini, W; Arai, Andrew E

    2018-03-08

    Dark rim artifacts in first-pass cardiovascular magnetic resonance (CMR) perfusion images can mimic perfusion defects and affect diagnostic accuracy for coronary artery disease (CAD). We evaluated whether quantitative myocardial blood flow (MBF) can differentiate dark rim artifacts from true perfusion defects in CMR perfusion. Regadenoson perfusion CMR was performed at 1.5 T in 76 patients. Significant CAD was defined by quantitative invasive coronary angiography (QCA) ≥ 50% diameter stenosis. Non-significant CAD (NonCAD) was defined as stenosis by QCA < 50% diameter stenosis or computed tomographic coronary angiography (CTA) < 30% in all major epicardial arteries. Dark rim artifacts had study specific and guideline-based definitions for comparison purposes. MBF was quantified at the pixel-level and sector-level. In a NonCAD subgroup with dark rim artifacts, stress MBF was lower in the subendocardial than midmyocardial and epicardial layers (2.17 ± 0.61 vs. 3.06 ± 0.75 vs. 3.24 ± 0.80 mL/min/g, both p < 0.001) and was also 30% lower than in remote regions (2.17 ± 0.61 vs. 2.83 ± 0.67 mL/min/g, p < 0.001). However, subendocardial stress MBF in dark rim artifacts was 37-56% higher than in true perfusion defects (2.17 ± 0.61 vs. 0.95 ± 0.43 mL/min/g, p < 0.001). Absolute stress MBF differentiated CAD from NonCAD with an accuracy ranging from 86 to 89% (all p < 0.001) using pixel-level analyses. Similar results were seen at a sector level. Quantitative stress MBF is lower in dark rim artifacts than remote myocardium but significantly higher than in true perfusion defects. If confirmed in larger series, this approach may aid the interpretation of clinical stress perfusion exams. ClinicalTrials.gov Identifier: NCT00027170 ; first posted 11/28/2001; updated 11/27/2017.

  2. CT Angiography after 20 Years

    PubMed Central

    Rubin, Geoffrey D.; Leipsic, Jonathon; Schoepf, U. Joseph; Fleischmann, Dominik; Napel, Sandy

    2015-01-01

    Through a marriage of spiral computed tomography (CT) and graphical volumetric image processing, CT angiography was born 20 years ago. Fueled by a series of technical innovations in CT and image processing, over the next 5–15 years, CT angiography toppled conventional angiography, the undisputed diagnostic reference standard for vascular disease for the prior 70 years, as the preferred modality for the diagnosis and characterization of most cardiovascular abnormalities. This review recounts the evolution of CT angiography from its development and early challenges to a maturing modality that has provided unique insights into cardiovascular disease characterization and management. Selected clinical challenges, which include acute aortic syndromes, peripheral vascular disease, aortic stent-graft and transcatheter aortic valve assessment, and coronary artery disease, are presented as contrasting examples of how CT angiography is changing our approach to cardiovascular disease diagnosis and management. Finally, the recently introduced capabilities for multispectral imaging, tissue perfusion imaging, and radiation dose reduction through iterative reconstruction are explored with consideration toward the continued refinement and advancement of CT angiography. PMID:24848958

  3. Tricuspid regurgitation by radionuclide angiography and contrast right ventriculography: a preliminary observation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumia, F.J.; Patil, A.; Germon, P.A.

    In a retrospective study correlating the degree of tricuspid regurgitation seen on first-pass radionuclide angiography with that seen on contrast right ventriculography in 51 patients, ten had no tricuspid regurgitation by contrast ventriculography, whereas by radionuclide angiography nine had no regurgitation and one had minimal regurgitation. Of eight patients with minimal tricuspid regurgitation by contrast ventriculography, five had minimal regurgitation by nuclide angiography and three had no regurgitation. Of the 11 patients with mild to moderate tricuspid regurgitation by contrast studies, ten had mild to moderate regurgitation and one had severe regurgitation by nuclide angiography. Of 22 patients with moderatemore » to severe tricuspid regurgitation by contrast studies, 15 had moderate to severe regurgitation and seven had mild to moderate regurgitation by nuclear angiography. In this preliminary study comparing radionuclide angiography with contrast right ventriculography, there were three false-negative and one false-positive nuclide angiograms, giving a sensitivity of 93% and a specificity of 90%.« less

  4. System and method for generating motion corrected tomographic images

    DOEpatents

    Gleason, Shaun S [Knoxville, TN; Goddard, Jr., James S.

    2012-05-01

    A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

  5. Optical tomographic memories: algorithms for the efficient information readout

    NASA Astrophysics Data System (ADS)

    Pantelic, Dejan V.

    1990-07-01

    Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different

  6. Coronary artery calcium scoring does not add prognostic value to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease.

    PubMed

    Kwon, Sung Woo; Kim, Young Jin; Shim, Jaemin; Sung, Ji Min; Han, Mi Eun; Kang, Dong Won; Kim, Ji-Ye; Choi, Byoung Wook; Chang, Hyuk-Jae

    2011-04-01

    To evaluate the prognostic outcome of cardiac computed tomography (CT) for prediction of major adverse cardiac events (MACEs) in low-risk patients suspected of having coronary artery disease (CAD) and to explore the differential prognostic values of coronary artery calcium (CAC) scoring and coronary CT angiography. Institutional review committee approval and informed consent were obtained. In 4338 patients who underwent 64-section CT for evaluation of suspected CAD, both CAC scoring and CT angiography were concurrently performed by using standard scanning protocols. Follow-up clinical outcome data regarding composite MACEs were procured. Multivariable Cox proportional hazards models were developed to predict MACEs. Risk-adjusted models incorporated traditional risk factors for CAC scoring and coronary CT angiography. During the mean follow-up of 828 days ± 380, there were 105 MACEs, for an event rate of 3%. The presence of obstructive CAD at coronary CT angiography had independent prognostic value, which escalated according to the number of stenosed vessels (P < .001). In the receiver operating characteristic curve (ROC) analysis, the superiority of coronary CT angiography to CAC scoring was demonstrated by a significantly greater area under the ROC curve (AUC) (0.892 vs 0.810, P < .001), whereas no significant incremental value for the addition of CAC scoring to coronary CT angiography was established (AUC = 0.892 for coronary CT angiography alone vs 0.902 with addition of CAC scoring, P = .198). Coronary CT angiography is better than CAC scoring in predicting MACEs in low-risk patients suspected of having CAD. Furthermore, the current standard multisection CT protocol (coronary CT angiography combined with CAC scoring) has no incremental prognostic value compared with coronary CT angiography alone. Therefore, in terms of determining prognosis, CAC scoring may no longer need to be incorporated in the cardiac CT protocol in this population. © RSNA, 2011.

  7. Relationship between the Self-Rating Anxiety Scale score and the success rate of 64-slice computed tomography coronary angiography.

    PubMed

    Li, Hui; Jin, Dan; Qiao, Fang; Chen, Jianchang; Gong, Jianping

    Computed tomography coronary angiography, a key method for obtaining coronary artery images, is widely used to screen for coronary artery diseases due to its noninvasive nature. In China, 64-slice computed tomography systems are now the most common models. As factors that directly affect computed tomography performance, heart rate and rhythm control are regulated by the autonomic nervous system and are highly related to the emotional state of the patient. The aim of this prospective study is to use a pre-computed tomography scan Self-Rating Anxiety Scale assessment to analyze the effects of tension and anxiety on computed tomography coronary angiography success. Subjects aged 18-85 years who were planned to undergo computed tomography coronary angiography were enrolled; 1 to 2 h before the computed tomography scan, basic patient data (gender, age, heart rate at rest, and family history) and Self-Rating Anxiety Scale score were obtained. The same group of imaging department doctors, technicians, and nurses performed computed tomography coronary angiography for all the enrolled subjects and observed whether those subjects could finish the computed tomography coronary angiography scan and provide clear, diagnostically valuable images. Participants were divided into successful (obtained diagnostically useful coronary images) and unsuccessful groups. Basic data and Self-Rating Anxiety Scale scores were compared between the groups. The Self-Rating Anxiety Scale standard score of the successful group was lower than that of the unsuccessful group (P = 0.001). As the Self-Rating Anxiety Scale standard score rose, the success rate of computed tomography coronary angiography decreased. The Self-Rating Anxiety Scale score has a negative relationship with computed tomography coronary angiography success. Anxiety can be a disadvantage in computed tomography coronary angiography examination. The pre-computed tomography coronary angiography scan Self-Rating Anxiety Scale score may be a useful tool for assessing whether a computed tomography coronary angiography scan will be successful or not. © The Author(s) 2015.

  8. CT angiography - abdomen and pelvis

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007674.htm CT angiography - abdomen and pelvis To use the sharing features on this page, please enable JavaScript. CT angiography combines a CT scan with the injection ...

  9. CT angiography - arms and legs

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007675.htm CT angiography - arms and legs To use the sharing features on this page, please enable JavaScript. CT angiography combines a CT scan with the injection ...

  10. CT angiography - head and neck

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007677.htm CT angiography - head and neck To use the sharing features on this page, please enable JavaScript. CT angiography (CTA) combines a CT scan with the ...

  11. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P < 0.01). In both superficial and deep network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P < 0.01). The deep network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  12. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents.

    PubMed

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia; Thoeny, Harriet C

    2010-03-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 +/- 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m(2)). Mean eGFR pre-angiography was 26 ml/min/1.73 m(2) and 33 ml/min/1.73 m(2) post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO(2) angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients.

  13. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    PubMed

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  14. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    PubMed

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  15. [X-ray computed tomographic abnormalities in schizophrenia. Trial of relationship with clinical data].

    PubMed

    D'Amato, T; Rochet, T; Dalery, J; Chauchat, J H; Terra, J L; Arteaga, C; Marie-Cardine, M

    1992-01-01

    Computerized tomography (CT-scan) studies in schizophrenia revealed that some patients have neuromorphological abnormalities. The structural changes consist mainly in lateral and third ventricle enlargement, and in cortical atrophy. The present study evaluates these three changes in 42 schizophrenics aged 18 to 50, compared to 24 healthy controls. Diagnosis were established from information gathered by personal interview with the SADS-LA. Clinical sub-types were evaluated according to the DSM III-R criteria. Moreover, detailed symptoms were rated according to the Positive And Negative Syndrome Scale (PANSS). CT scans were recorded in floppy disks and blindly analyzed. Schizophrenics shown significant higher mean size of lateral and third ventricles, and higher mean anterior cortical atrophy than healthy subjects. Significant differences were also found between subtypes, with more marked abnormalities in the disorganized group. The relationship between brain abnormalities and clinical symptoms recorded with the PANSS, were analysed using Pearson correlates. Positive correlations concerned mainly negative symptoms like blunted affect, emotional withdrawal, difficulties in abstract thinking, passive apathetic social withdrawal and lack of spontaneity of conversation. Positive correlations are also observed with some symptoms classified with the PANSS in the General Psychopathology scale such as mannerism and disorientation. Negative correlation concerned most of PANSS positive symptoms.

  16. Pseudo-shading technique in the two-dimensional domain: a post-processing algorithm for enhancing the Z-buffer of a three-dimensional binary image.

    PubMed

    Tan, A C; Richards, R

    1989-01-01

    Three-dimensional (3D) medical graphics is becoming popular in clinical use on tomographic scanners. Research work in 3D reconstructive display of computerized tomography (CT) and magnetic resonance imaging (MRI) scans on conventional computers has produced many so-called pseudo-3D images. The quality of these images depends on the rendering algorithm, the coarseness of the digitized object, the number of grey levels and the image screen resolution. CT and MRI data are fundamentally voxel based and they produce images that are coarse because of the resolution of the data acquisition system. 3D images produced by the Z-buffer depth shading technique suffer loss of detail when complex objects with fine textural detail need to be displayed. Attempts have been made to improve the display of voxel objects, and existing techniques have shown the improvement possible using these post-processing algorithms. The improved rendering technique works on the Z-buffer image to generate a shaded image using a single light source in any direction. The effectiveness of the technique in generating a shaded image has been shown to be a useful means of presenting 3D information for clinical use.

  17. Electrical properties of rat muscle after sciatic nerve injury: Impact on surface impedance measurements assessed via finite element analysis

    NASA Astrophysics Data System (ADS)

    Ahad, M. A.; Rutkove, S. B.

    2010-04-01

    Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.

  18. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  19. Finite element method framework for RF-based through-the-wall mapping

    NASA Astrophysics Data System (ADS)

    Campos, Rafael Saraiva; Lovisolo, Lisandro; de Campos, Marcello Luiz R.

    2017-05-01

    Radiofrequency (RF) Through-the-Wall Mapping (TWM) employs techniques originally applied in X-Ray Computerized Tomographic Imaging to map obstacles behind walls. It aims to provide valuable information for rescuing efforts in damaged buildings, as well as for military operations in urban scenarios. This work defines a Finite Element Method (FEM) based framework to allow fast and accurate simulations of the reconstruction of floors blueprints, using Ultra High-Frequency (UHF) signals at three different frequencies (500 MHz, 1 GHz and 2 GHz). To the best of our knowledge, this is the first use of FEM in a TWM scenario. This framework allows quick evaluation of different algorithms without the need to assemble a full test setup, which might not be available due to budgetary and time constraints. Using this, the present work evaluates a collection of reconstruction methods (Filtered Backprojection Reconstruction, Direct Fourier Reconstruction, Algebraic Reconstruction and Simultaneous Iterative Reconstruction) under a parallel-beam acquisition geometry for different spatial sampling rates, number of projections, antenna gains and operational frequencies. The use of multiple frequencies assesses the trade-off between higher resolution at shorter wavelengths and lower through-the-wall penetration. Considering all the drawbacks associated with such a complex problem, a robust and reliable computational setup based on a flexible method such as FEM can be very useful.

  20. Comparison study on the feasibility of photoacoustic power spectrum analysis in osteoporosis detection

    NASA Astrophysics Data System (ADS)

    He, Weizhen; Zhu, Yunhao; Feng, Ting; Wang, Huaideng; Yuan, Jie; Xu, Guan; Wang, Xueding; Carson, Paul

    2017-03-01

    Osteoporosis is a progressive bone disease which is characterized by a decrease in the bone mass and deterioration in bone micro-architecture. In theory, photoacoustic (PA) imaging analysis has potential to obtain the characteristics of the bone effectively. Previous study demonstrated that photoacoustic spectral analysis (PASA) method with the qualified parameter slope could provide an objective assessment of bone microstructure and deterioration. In this study, we tried to compare PASA method with the traditional quantitative ultrasound (QUS) method in osteoporosis assessment. Numerical simulations of both PA and ultrasound (US) signal are performed on computerized tomographic (CT) images of trabecular bone with different bone mineral densities (BMDs). Ex vivo experiments were conducted on porcine femur bone model of different BMDs. We compared the quantified parameter slope and the broadband ultrasound attenuation (BUA) coefficient from the PASA and QUS among different bone models, respectively. Both the simulation and ex vivo experiment results show that bone with low BMD has a higher slope value and lower BUA value. Our result demonstrated that the PASA method has the same efficacy with QUS in bone assessment, considering PA is a non-ionizing, non-invasive technique, PASA method holds potential for clinical diagnosis in osteoporosis and other bone diseases.

  1. Creation of virtual patients from CT images of cadavers to enhance integration of clinical and basic science student learning in anatomy.

    PubMed

    Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F

    2009-08-01

    The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.

  2. Pulmonary Thromboembolism: Evaluation By Intravenous Angiography

    NASA Astrophysics Data System (ADS)

    Pond, Gerald D.; Cook, Glenn C.; Woolfenden, James M.; Dodge, Russell R.

    1981-11-01

    Using perfusion lung scans as a guide, digital video subtraction angiography of the pulmonary arteries was performed in human subjects suspected of having pulmonary embolism. Dogs were employed as a pulmonary embolism model and both routine pulmonary angiography and intravenous pulmonary angiograms were obtained for comparison purposes. We have shown by our preliminary results that the technique is extremely promising as a safe and accurate alternative to routine pulmonary angiography in selected patients.

  3. CT angiography of the renal arteries and veins: normal anatomy and variants.

    PubMed

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  4. In Response to Laovirojjanakul W, Acharya N and Gonzales JA's "Ultra-Widefield Fluorescein Angiography in Intermediate Uveitis".

    PubMed

    Babu, Kalpana; Kumaradas, Mrinalini

    2017-12-28

    We read with great interest the article by Laovirojjanakul et al. on ultra-widefield fluorescein angiography in intermediate uveitis. We would like to share a similar case of chronic intermediate uveitis highlighting a fern-like pattern of diffuse vascular leakage on fluorescein angiography, with good visual acuity, absence of clinically active inflammation, and a similar fluorescein angiography picture over a follow-up of 4 years.

  5. New developments in multimodal clinical multiphoton tomography

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2011-03-01

    80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.

  6. Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes

    PubMed Central

    Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.

    2016-01-01

    Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614

  7. Current Perspectives in Imaging Modalities for the Assessment of Unruptured Intracranial Aneurysms: A Comparative Analysis and Review.

    PubMed

    Turan, Nefize; Heider, Robert A; Roy, Anil K; Miller, Brandon A; Mullins, Mark E; Barrow, Daniel L; Grossberg, Jonathan; Pradilla, Gustavo

    2018-05-01

    Intracranial aneurysms (IAs) are pathologic dilatations of cerebral arteries. This systematic review summarizes and compares imaging techniques for assessing unruptured IAs (UIAs). This review also addresses their uses in different scopes of practice. Pathophysiologic mechanisms are reviewed to better understand the clinical usefulness of each imaging modality. A literature review was performed using PubMed with these search terms: "intracranial aneurysm," "cerebral aneurysm," "magnetic resonance angiography (MRA)," computed tomography angiography (CTA)," "catheter angiography," "digital subtraction angiography," "molecular imaging," "ferumoxytol," and "myeloperoxidase". Only studies in English were cited. Since the development and improvement of noninvasive diagnostic imaging (computed tomography angiography and magnetic resonance angiography), many prospective studies and meta-analyses have compared these tests with gold standard digital subtraction angiography (DSA). Although computed tomography angiography and magnetic resonance angiography have lower detection rates for UIAs, they are vital in the treatment and follow-up of UIAs. The reduction in ionizing radiation and lack of endovascular instrumentation with these modalities provide benefits compared with DSA. Novel molecular imaging techniques to detect inflammation within the aneurysmal wall with the goal of stratifying risk based on level of inflammation are under investigation. DSA remains the gold standard for preoperative planning and follow-up for patients with IA. Newer imaging modalities such as ferumoxytol-enhanced magnetic resonance imaging are emerging techniques that provide critical in vivo information about the inflammatory milieu within aneurysm walls. With further study, these techniques may provide aneurysm rupture risk and prediction models for individualized patient care. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Coronary CT Angiography-derived Fractional Flow Reserve: Machine Learning Algorithm versus Computational Fluid Dynamics Modeling.

    PubMed

    Tesche, Christian; De Cecco, Carlo N; Baumann, Stefan; Renker, Matthias; McLaurin, Tindal W; Duguay, Taylor M; Bayer, Richard R; Steinberg, Daniel H; Grant, Katharine L; Canstein, Christian; Schwemmer, Chris; Schoebinger, Max; Itu, Lucian M; Rapaka, Saikiran; Sharma, Puneet; Schoepf, U Joseph

    2018-04-10

    Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFR CFD ) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFR ML )-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFR CFD and FFR ML . The performance of both techniques for detecting lesion-specific ischemia was compared against visual stenosis grading at coronary CT angiography, QCA, and invasive FFR as the reference standard. Results On a per-lesion and per-patient level, FFR ML showed a sensitivity of 79% and 90% and a specificity of 94% and 95%, respectively, for detecting lesion-specific ischemia. Meanwhile, FFR CFD resulted in a sensitivity of 79% and 89% and a specificity of 93% and 93%, respectively, on a per-lesion and per-patient basis (P = .86 and P = .92). On a per-lesion level, the area under the receiver operating characteristics curve (AUC) of 0.89 for FFR ML and 0.89 for FFR CFD showed significantly higher discriminatory power for detecting lesion-specific ischemia compared with that of coronary CT angiography (AUC, 0.61) and QCA (AUC, 0.69) (all P < .0001). Also, on a per-patient level, FFR ML (AUC, 0.91) and FFR CFD (AUC, 0.91) performed significantly better than did coronary CT angiography (AUC, 0.65) and QCA (AUC, 0.68) (all P < .0001). Processing time for FFR ML was significantly shorter compared with that of FFR CFD (40.5 minutes ± 6.3 vs 43.4 minutes ± 7.1; P = .042). Conclusion The FFR ML algorithm performs equally in detecting lesion-specific ischemia when compared with the FFR CFD approach. Both methods outperform accuracy of coronary CT angiography and QCA in the detection of flow-limiting stenosis. © RSNA, 2018.

  9. Infrared-laser-based fundus angiography

    NASA Astrophysics Data System (ADS)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  10. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin

    2007-09-15

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels.

  11. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasationmore » of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.« less

  12. Revascularization of Left Coronary System Using a Skeletonized Left Internal Mammary Artery - Sequential vs. Separate Grafting.

    PubMed

    Ji, Qiang; Shi, YunQing; Xia, LiMin; Ma, RunHua; Shen, JinQiang; Lai, Hao; Ding, WenJun; Wang, ChunSheng

    2017-12-25

    To evaluate in-hospital and mid-term outcomes of sequential vs. separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study.Methods and Results:After propensity score-matching, 120 pairs of patients undergoing first scheduled isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Both propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. Sequential LIMA grafting was not found to be an independent predictor of adverse events. During a follow-up period of 27.0±7.3 months, 99.1% patency for the diagonal site and 98.3% for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.

  13. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    PubMed

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  14. Reconstructive valve surgery within 10 days of stroke in endocarditis.

    PubMed

    Raman, Jai; Ballal, Apoorva; Hota, Bala; Mirza, Sara; Lai, David; Bleck, Thomas; Lateef, Omar

    2016-07-01

    The optimal timing of surgical treatment for infective endocarditis complicated by cerebrovascular events is controversial, largely due to the perceived risk of perioperative intracranial bleeding. Current guidelines suggest waiting 2 weeks between the diagnosis of stroke and surgery. The aim of this study was to investigate the clinical and neurological outcomes of early surgery following a stroke. This was a single-center retrospective analysis of 12 consecutive patients requiring surgery for infective endocarditis between 2011 and 2014 at Rush University Medical Center, with either ischemic (n = 6) and/or hemorrhagic (n = 6) cerebrovascular complications. All underwent computed tomographic angiography prior to early valve reconstructive surgery to identify potentially actionable neurological findings. Early valve surgery was performed for ongoing sepsis or persistent emboli. Neurologic risk and outcome were assessed pre- and postoperatively using the National Institutes of Health Stroke Scale and the Glasgow Outcome Scale, respectively. All 12 patients underwent surgical treatment within 10 days of the diagnosis of stroke. Mortality in the immediate postoperative period was 8%. Eleven of the 12 patients exhibited good neurological recovery in the immediate postoperative period, with a Glasgow Outcome Scale score ≥ 3. There was no correlation between duration of cardiopulmonary bypass and neurological outcomes. Early cardiac surgery in patients with infective endocarditis and stroke maybe lifesaving with a low neurological risk. Comprehensive neurovascular imaging may help in identifying patient-related risk factors. © The Author(s) 2016.

  15. Neck Pain One Week after Pacemaker Generator Replacement.

    PubMed

    Graham, Ross F; Wightman, John M

    2015-07-01

    The incidence of cardiac pacemaker implantation has risen markedly in the past three decades, making awareness of possible postprocedural complications critical to the emergency physician. This case is the first documented instance of internal jugular (IJ) deep vein thrombosis (DVT) from an uncomplicated pacemaker generator replacement. A patient presented to an Emergency Department with a 2-day history of mild left temporal headache migrating to his left neck. The patient did not volunteer this information, but review of systems revealed a temporary transvenous pacemaker inserted through the right IJ vein 1 week previously during a routine exchange of a left-sided cardiac pacemaker generator. Manipulation of the existing pacemaker wires entering the left subclavian vein was minimal. Computed tomographic angiography of the neck demonstrated near-complete thrombotic occlusion of the entire length of his left IJ vein. This required hospital admission for observation and treatment with anticoagulation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: DVT, with thrombotic extension into adjacent vessels anywhere along the course of pacemaker wires, should be considered by the emergency provider in the evaluation of head, neck, or upper extremity symptoms after recent or remote implantation or manipulation of a transvenous cardiac pacemaker, including generator replacement. Failure to identify and treat appropriately could result in significant morbidity and mortality from airway edema, septic thrombophlebitis, superior vena cava syndrome, superior sagittal sinus thrombosis, or pulmonary embolism. Published by Elsevier Inc.

  16. Combined Rex-bypass shunt with pericardial devascularization alleviated prehepatic portal hypertension caused by cavernomatous transformation of portal vein.

    PubMed

    Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang

    2017-09-01

    To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P < 0.05), the blood flow velocity (P < 0.05) and diameter (P < 0.05) of the left portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P < 0.05), and better effects of earlier operations were demonstrated than the delayed ones (P < 0.05). During the period of follow-up from 6 to 64 months, the overall patency rate was 85.7% and the younger the age the better of the effect. Rex-bypass shunt combined with pericardial devascularization is a safe and effective procedure for prehepatic portal hypertension caused by CTPV.

  17. Coronary angiography in worsening heart failure: determinants, findings and prognostic implications.

    PubMed

    Ferreira, João Pedro; Rossignol, Patrick; Demissei, Biniyam; Sharma, Abhinav; Girerd, Nicolas; Anker, Stefan D; Cleland, John G; Dickstein, Kenneth; Filippatos, Gerasimos; Hillege, Hans L; Lang, Chim C; Metra, Marco; Ng, Leong L; Ponikowski, Piotr; Samani, Nilesh J; van Veldhuisen, Dirk J; Zwinderman, Aeilko H; Voors, Adriaan; Zannad, Faiez

    2018-04-01

    Coronary angiography is regularly performed in patients with worsening signs and/or symptoms of heart failure (HF). However, little is known on the determinants, findings and associated clinical outcomes of coronary angiography performed in patients with worsening HF. The BIOSTAT-CHF (a systems BIOlogy Study to TAilored Treatment in Chronic Heart Failure) programme enrolled 2516 patients with worsening symptoms and/or signs of HF, either hospitalised or in the outpatient setting. All patients were included in the present analysis. Of the 2516 patients included, 315 (12.5%) underwent coronary angiography within the 30 days after the onset of worsening symptoms and/or signs of HF. Subjects who underwent angiography were more often observed as inpatients, had more often an overt acute coronary syndrome, had higher troponin I levels, were younger and had better renal function (all p≤0.01). Patients who underwent coronary angiography had a lower risk of the primary outcome of death and/or HF hospitalisation (adjusted HR=0.71, 95% CI 0.57 to 0.89, p=0.003) and death (adjusted HR=0.59, 95% CI 0.43 to 0.80, p=0.001). Among the patients who underwent coronary angiography, those with a coronary stenosis (39%) had a worse prognosis than those without stenosis (adjusted HR for the primary outcome=1.71, 95% CI 1.10 to 2.64, p=0.016). Coronary angiography was performed in <13% of patients with symptoms and/or signs of worsening HF. These patients were remarkably different from those who did not undergo coronary angiography and had a lower risk of subsequent events. The presence of coronary stenosis on coronary angiography was associated with a worse prognosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Methods and algorithms for optical coherence tomography-based angiography: a review and comparison

    NASA Astrophysics Data System (ADS)

    Zhang, Anqi; Zhang, Qinqin; Chen, Chieh-Li; Wang, Ruikang K.

    2015-10-01

    Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance, phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.

  19. Dark and white lesions observed in central serous chorioretinopathy on optical coherence tomography angiography.

    PubMed

    De Bats, Flore; Cornut, Pierre-Loïc; Wolff, Benjamin; Kodjikian, Laurent; Mauget-Faÿsse, Martine

    2018-03-01

    To describe abnormal dark (hyposignal) and white (hypersignal) lesions observed on optical coherence tomography angiography in central serous chorioretinopathy. Prospective, multicenter, and descriptive study including patients with active or quiescent central serous chorioretinopathy. All patients had undergone a complete ophthalmic examination. Abnormal dark lesions were detected as "dark spots" and "dark areas" on optical coherence tomography angiography. A "dark spot" could correspond to six different abnormalities: pigment epithelium detachment, subretinal deposit, "Lucency" within surrounding subretinal fibrin, choroidal cavitation, choroidal excavation, and choroidal fluid. A "dark area" could be related to a serous retinal detachment or choriocapillary compression. Abnormal white lesions were also detected: A "white spot" could correspond with the leaking point on fluorescein angiography or with hyper-reflective dots; A "white filamentous pattern" at the Brüch's membrane level corresponded to abnormal choroidal neovascular vessels. A semiology is described using optical coherence tomography angiography in central serous chorioretinopathy as abnormal dark and white lesions. Multimodal imaging is mandatory in addition to optical coherence tomography angiography to diagnose non-neovascular retinal and choroidal central serous chorioretinopathy lesions. However, optical coherence tomography angiography alone is helpful in detecting choroidal neovascular membrane in central serous chorioretinopathy.

  20. First results from the ionospheric tomography experiment using beacon TEC data obtained by means of a network along a longitude of 136°E over Japan

    NASA Astrophysics Data System (ADS)

    Thampi, Smitha V.; Yamamoto, Mamoru

    2010-03-01

    A chain of newly designed GNU (GNU is not UNIX) Radio Beacon Receivers (GRBR) has recently been established over Japan, primarily for tomographic imaging of the ionosphere over this region. Receivers installed at Shionomisaki (33.45°N, 135.8°E), Shigaraki (34.8°N, 136.1°E), and Fukui (36°N, 136°E) continuously track low earth orbiting satellites (LEOS), mainly OSCAR, Cosmos, and FORMOSAT-3/COSMIC, to obtain simultaneous total electron content (TEC) data from these three locations, which are then used for the tomographic reconstruction of ionospheric electron densities. This is the first GRBR network established for TEC observations, and the first beacon-based tomographic imaging in Japanese longitudes. The first tomographic images revealed the temporal evolution with all of the major features in the ionospheric electron density distribution over Japan. A comparison of the tomographically reconstructed electron densities with the ƒ o F 2 data from Kokubunji (35°N, 139°E) revealed that there was good agreement between the datasets. These first results show the potential of GRBR and its network for making continuous, unattended ionospheric TEC measurements and for tomographic imaging of the ionosphere.

  1. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    PubMed

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  2. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    PubMed

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  3. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial

    PubMed Central

    Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-01-01

    Objective To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease. Design Prospective randomised single centre trial. Setting University hospital in Germany. Participants 340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain. Interventions 168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes. Main outcome measure The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography. Results Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients stated that they would prefer CT for subsequent testing. The study was conducted at a University hospital in Germany and thus the performance of CT may be different in routine clinical practice. The prevalence was lower than expected, resulting in an underpowered study for the predefined primary outcome. Conclusions CT increased the diagnostic yield and was a safe gatekeeper for coronary angiography with no increase in long term events. The length of stay was shortened by 22.9 hours with CT, and patients preferred non-invasive testing. Trial registration ClinicalTrials.gov NCT00844220. PMID:27777234

  4. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial.

    PubMed

    Dewey, Marc; Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-10-24

     To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease.  Prospective randomised single centre trial.  University hospital in Germany.  340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain.  168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes.  The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography.  Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients stated that they would prefer CT for subsequent testing. The study was conducted at a University hospital in Germany and thus the performance of CT may be different in routine clinical practice. The prevalence was lower than expected, resulting in an underpowered study for the predefined primary outcome.  CT increased the diagnostic yield and was a safe gatekeeper for coronary angiography with no increase in long term events. The length of stay was shortened by 22.9 hours with CT, and patients preferred non-invasive testing.Trial registration ClinicalTrials.gov NCT00844220. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. On the feasibility of tomographic-PIV with low pulse energy illumination in a lifted turbulent jet flame

    NASA Astrophysics Data System (ADS)

    Boxx, I.; Carter, C. D.; Meier, W.

    2014-08-01

    Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.

  6. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  7. Clinical, radiographic, ultrasonographic and computed tomographic features of nonseptic osteitis of the axial border of the proximal sesamoid bones.

    PubMed

    Vanderperren, K; Bergman, H J; Spoormakers, T J P; Pille, F; Duchateau, L; Puchalski, S M; Saunders, J H

    2014-07-01

    Lysis of the axial aspect of equine proximal sesamoid bones (PSBs) is a rare condition reported to have septic or traumatic origins. Limited information exists regarding imaging of nonseptic axial osteitis of a PSB. To report the clinical, radiographic, ultrasonographic, computed tomographic and intra-arterial contrast-enhanced computed tomographic abnormalities in horses with axial nonseptic osteitis of a PSB. Retrospective clinical study. Eighteen horses diagnosed with nonseptic osteitis of the axial border of a PSB between 2007 and 2012 were reviewed retrospectively. Case details, clinical examination, radiographic, ultrasonographic, computed tomographic and intra-arterial/intra-articular contrast-enhanced computed tomographic features were recorded, when available. Radiographic, ultrasonographic and computed tomographic evaluations of the fetlock region had been performed on 18, 15 and 9 horses, respectively. The effect of the degree of lysis on the grade and duration of lameness was determined. All horses had chronic unilateral lameness, 4 with forelimb and 14 with hindlimb signs. On radiographs, lysis was identified in both PSBs in 14 horses, one PSB in 3 horses and in one horse no lysis was identified. The degree of osteolysis was variable. Ultrasonography identified variably sized irregularities of the bone surface and alteration in echogenicity of the palmar/plantar ligament (PL). All horses undergoing computed tomographic examination (n = 9) had biaxial lysis. The lesions were significantly longer and deeper on computed tomographic images compared with radiographic images. Intra-arterial contrast-enhanced computed tomography may reveal moderate to marked contrast enhancement of the PL. There was no significant effect of the degree of lysis on the grade and duration of lameness. Lesions of nonseptic axial osteitis of a PSB can be identified using a combination of radiography and ultrasonography. Computed tomography provides additional information regarding the extent of the pathology. © 2013 EVJ Ltd.

  8. The utility of postmortem computed tomography selective coronary angiography in parallel with autopsy.

    PubMed

    Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro

    2013-12-01

    Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.

  9. The use of carbon dioxide angiography for renal sympathetic denervation: a technical report.

    PubMed

    Renton, Mary; Hameed, Mohammad A; Dasgupta, Indranil; Hoey, Edward T D; Freedman, Jonathan; Ganeshan, Arul

    2016-12-01

    Hypertension is the leading attributable cause of cardiovascular mortality worldwide. Patients with hypertension have multiple comorbidities including high rates of concomitant renal disease. Current pharmacological approaches are inadequate in the treatment of resistant hypertension. Renal sympathetic denervation (RDN) has been shown to effectively treat resistant hypertension. The traditional use of iodinated contrast in RDN is contraindicated in patients with significant renal insufficiency. In patients with renal impairment, carbon dioxide (CO 2 ) can be used as an alternative contrast material for RDN. This article describes the technical aspects of RDN using CO 2 angiography. Our centre is experienced in the innovative RDN procedure using CO 2 angiography. We describe the protocol for CO 2 angiography for RDN using a home-made CO 2 delivery system and the Symplicity ™ (Minneapolis MN 55432 USA) catheter (Medtronic) device. CO 2 angiography is an excellent alternative to iodinated contrast for RDN procedures. CO 2 angiography for RDN is a safe and effective alternative to iodinated contrast. RDN using CO 2 angiography is an easy and feasible procedure that can be used in patients with renal insufficiency or iodinated contrast allergies. Advances in knowledge: There is a paucity of descriptive reports for CO 2 angiography for RDN and we provide details of the optimal protocol for the procedure. In particular, we describe the use of a Symplicity Spyral ™ catheter (Medtronic), which has not been reported to date for use in this procedure.

  10. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks.

    PubMed

    López-Linares, Karen; Aranjuelo, Nerea; Kabongo, Luis; Maclair, Gregory; Lete, Nerea; Ceresa, Mario; García-Familiar, Ainhoa; Macía, Iván; González Ballester, Miguel A

    2018-05-01

    Computerized Tomography Angiography (CTA) based follow-up of Abdominal Aortic Aneurysms (AAA) treated with Endovascular Aneurysm Repair (EVAR) is essential to evaluate the progress of the patient and detect complications. In this context, accurate quantification of post-operative thrombus volume is required. However, a proper evaluation is hindered by the lack of automatic, robust and reproducible thrombus segmentation algorithms. We propose a new fully automatic approach based on Deep Convolutional Neural Networks (DCNN) for robust and reproducible thrombus region of interest detection and subsequent fine thrombus segmentation. The DetecNet detection network is adapted to perform region of interest extraction from a complete CTA and a new segmentation network architecture, based on Fully Convolutional Networks and a Holistically-Nested Edge Detection Network, is presented. These networks are trained, validated and tested in 13 post-operative CTA volumes of different patients using a 4-fold cross-validation approach to provide more robustness to the results. Our pipeline achieves a Dice score of more than 82% for post-operative thrombus segmentation and provides a mean relative volume difference between ground truth and automatic segmentation that lays within the experienced human observer variance without the need of human intervention in most common cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... magnetic media, such as magnetic tapes or magnetic diskettes, containing the computerized information at.... The computerized magnetic media shall be prepared and delivered at the committee's expense and shall... Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal...

  12. SIRT-FILTER v1.0.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PELT, DANIEL

    2017-04-21

    Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).

  13. Quantitation of mandibular ramus volume as a source of bone grafting.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p < 0.001). The bone volume measured 6 months post-sinus augmentation averaged 2.2 mL (SD 0.4 mL, range: 1.6-2.8 mL) with a mean loss of 0.3 mL in volume. The mandibular second molar area provided the thickest cortical graft. A cortical plate of 2.8 mm in average at combined second and third molar areas provided 2.5 mL particulated volume. The use of a design software program can improve surgical treatment planning prior to ramus bone grafting. The AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  14. Magnetic resonance angiography of the pediatric abdomen and pelvis: techniques and imaging findings.

    PubMed

    Sada, David M; Vellody, Ranjith; Liu, Peter S

    2013-11-01

    Although traditional catheter-based angiography has been the gold standard for pediatric abdominal and pelvic vascular imaging for the past several decades, advances in magnetic resonance angiography (MRA) have made it a viable alternative. MRA offers several advantages in that it is noninvasive, can be performed without ionizing radiation, and does not necessarily rely on contrast administration. The ability of modern MRA techniques to define variant vascular anatomy and detect vascular disease may obviate traditional angiography in some patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    PubMed

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  16. OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY SHOWS INNER CHOROIDAL ISCHEMIA IN ACUTE POSTERIOR MULTIFOCAL PLACOID PIGMENT EPITHELIOPATHY.

    PubMed

    Dolz-Marco, Rosa; Sarraf, David; Giovinazzo, Vincent; Freund, K Bailey

    2017-01-01

    To describe multimodal imaging findings of an evolving case of acute posterior multifocal placoid pigment epitheliopathy occurring in a young healthy male. Case report of a patient with acute posterior multifocal placoid pigment epitheliopathy including comprehensive systemic and ocular examinations. Ultra-widefield autofluorescence, fluorescein angiography, indocyanine green angiography, and serial optical coherence tomography angiography were performed. A 34-year-old male presented with acute vision loss in his left eye for 2 weeks. His best-corrected visual acuity was 20/20 in his right eye and 20/200 in his left eye. Dilated funduscopic examination revealed multiple creamy white deep retinal lesions showing macular involvement of the left eye with a diffuse area of pigmentary changes. The presence of multiple areas of hypoperfusion of the inner choroid were demonstrated with fluorescein and indocyanine green angiography. Serial optical coherence tomography angiography showed multiple evolving areas of decreased flow at the level of the inner choroid. Although the pathogenesis of acute posterior multifocal placoid pigment epitheliopathy remains unknown, there is growing evidence of a primary choroidal involvement with secondary damage to the overlying retinal pigment epithelium and the outer retinal layers. Optical coherence tomography angiography may provide valuable information for the diagnosis and follow-up of this condition avoiding invasive angiographic procedures.

  17. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    PubMed Central

    Ito, Hiromichi; Matsushita, Shonosuke; Hyodo, Kazuyuki; Sato, Yukio; Sakakibara, Yuzuru

    2013-01-01

    Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity. PMID:23412496

  18. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özgen, Ali, E-mail: draliozgen@hotmail.com; Sanioğlu, Soner; Bingöl, Uğur Anıl

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatininemore » levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.« less

  19. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    PubMed

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  20. Systematic preoperative coronary angiography and stenting improves postoperative results of carotid endarterectomy in patients with asymptomatic coronary artery disease: a randomised controlled trial.

    PubMed

    Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L

    2010-02-01

    To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography before carotid surgery was 4 times less likely to have a cardiac ischaemic event after carotid surgery. No complications related to coronary angiography were observed and no cervical haematomas occurred in patients undergoing surgery under aspirin and clopidogrel in this study. Systematic preoperative coronary angiography, possibly followed by PCI, significantly reduces the incidence of postoperative myocardial events after CEA in patients without clinical evidence of CAD. Copyright (c) 2009 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Magnetic resonance angiography in the follow-up of distal lower-extremity bypass surgery: comparison with duplex ultrasound and digital subtraction angiography.

    PubMed

    Meissner, Oliver A; Verrel, Frauke; Tató, Federico; Siebert, Uwe; Ramirez, Heldin; Ruppert, Volker; Schoenberg, Stefan O; Reiser, Maximilian

    2004-11-01

    The danger of limb loss as a consequence of acute occlusion of infrapopliteal bypasses underscores the requirement for careful patient follow-up. The objective of this study was to determine the agreement and accuracy of contrast material-enhanced moving-table magnetic resonance (MR) angiography and duplex ultrasonography (US) in the assessment of failing bypass grafts. In cases of discrepancy, digital subtraction angiography (DSA) served as the reference standard. MR angiography was performed in 24 consecutive patients with 26 femorotibial or femoropedal bypass grafts. Each revascularized limb was divided into five segments--(i) native arteries proximal to the graft; (ii) proximal anastomosis; (iii) graft course; (iv) distal anastomosis; and (v) native arteries distal to the graft-resulting in 130 vascular segments. Three readers evaluated all MR angiograms for image quality and the presence of failing grafts. The degree of stenosis was compared to the findings of duplex US, and in case of discrepancy, to DSA findings. Two separate analyses were performed with use of DSA only and a combined diagnostic endpoint as the reference standard. Image quality was rated excellent or intermediate in 119 of 130 vascular segments (92%). Venous overlay was encountered in 26 of 130 segments (20%). In only two segments was evaluation of the outflow region not feasible. One hundred seventeen of 130 vascular segments were available for quantitative analysis. In 109 of 117 segments (93%), MR angiography and duplex US showed concordant findings. In the eight discordant segments in seven patients, duplex US overlooked four high-grade stenoses that were correctly identified by MR angiography and confirmed by DSA. Percutaneous transluminal angioplasty was performed in these cases. In no case did MR angiography miss an area of stenosis of sufficient severity to require treatment. Total accuracy for duplex US ranged from 0.90 to 0.97 depending on the reference standard used, whereas MR angiography was completely accurate (1.00) regardless of the standard definition. Our data strongly suggest that the accuracy of MR angiography for identifying failing grafts in the infrapopliteal circulation is equal to that of duplex US and superior to that of duplex US in cases of complex revascularization. MR angiography should be included in routine follow-up of patients undergoing infrapopliteal bypass surgery.

  2. A review of US anthropometric reference data (1971 2000) with comparisons to both stylized and tomographic anatomic models

    NASA Astrophysics Data System (ADS)

    Huh, C.; Bolch, W. E.

    2003-10-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ~5%), present-day 40-year-old males have an average total body mass that is ~16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males. Both Helga (27-year-old F) and Donna, however, provide good matches to average US sitting heights for adult females, while Golem and Otoko (male of unknown age) yield sitting heights that are slightly below US adult male averages. Finally, Helga is seen as the only GSF tomographic female model that yields a body mass index in line with her average US female counterpart at age 26. In terms of dose reconstruction activities, however, all current tomographic voxel models are valuable assets in attempting to cover the broad distribution of individual anthropometric parameters representative of the current US population. It is highly recommended that similar attempts to create a broad library of tomographic models be initiated in the United States and elsewhere to complement and extend the limited number of tomographic models presently available for these efforts.

  3. Critical factors influencing physicians' intention to use computerized clinical practice guidelines: an integrative model of activity theory and the technology acceptance model.

    PubMed

    Hsiao, Ju-Ling; Chen, Rai-Fu

    2016-01-16

    With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p < 0.001), organizational support (γ = 0.285, p < 0.001), perceived usefulness of computerized clinical practice guidelines (γ = 0.219, p < 0.05), and social influence (γ = 0.213, p < 0.05) were critical factors influencing physicians' intention to use computerized clinical practice guidelines, and these factors can explain 68.6 % of the variance in intention to use computerized clinical practice guidelines. This study confirmed that some subject (human) factors, environment (organization) factors, tool (technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.

  4. 39 CFR 501.15 - Computerized Meter Resetting System.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...

  5. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    NASA Astrophysics Data System (ADS)

    Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2003-04-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

  6. High-Energy, High-Pulse-Rate Light Sources for Enhanced Time-Resolved Tomographic PIV of Unsteady and Turbulent Flows

    DTIC Science & Technology

    2017-07-31

    Report: High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows The views, opinions and/or...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows Report Term: 0-Other Email

  7. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...

  8. Image processing pipeline for synchrotron-radiation-based tomographic microscopy.

    PubMed

    Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M

    2010-07-01

    With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.

  9. Tomographic imaging of OH laser-induced fluorescence in laminar and turbulent jet flames

    NASA Astrophysics Data System (ADS)

    Li, Tao; Pareja, Jhon; Fuest, Frederik; Schütte, Manuel; Zhou, Yihui; Dreizler, Andreas; Böhm, Benjamin

    2018-01-01

    In this paper a new approach for 3D flame structure diagnostics using tomographic laser-induced fluorescence (Tomo-LIF) of the OH radical was evaluated. The approach combined volumetric illumination with a multi-camera detection system of eight views. Single-shot measurements were performed in a methane/air premixed laminar flame and in a non-premixed turbulent methane jet flame. 3D OH fluorescence distributions in the flames were reconstructed using the simultaneous multiplicative algebraic reconstruction technique. The tomographic measurements were compared and validated against results of OH-PLIF in the laminar flame. The effects of the experimental setup of the detection system and the size of the volumetric illumination on the quality of the tomographic reconstructions were evaluated. Results revealed that the Tomo-LIF is suitable for volumetric reconstruction of flame structures with acceptable spatial resolution and uncertainty. It was found that the number of views and their angular orientation have a strong influence on the quality and accuracy of the tomographic reconstruction while the illumination volume thickness influences mainly the spatial resolution.

  10. A comparison of free autologous breast reconstruction with and without the use of laser-assisted indocyanine green angiography: a cost-effectiveness analysis.

    PubMed

    Chatterjee, Abhishek; Krishnan, Naveen M; Van Vliet, Michael M; Powell, Stephen G; Rosen, Joseph M; Ridgway, Emily B

    2013-05-01

    Laser-assisted indocyanine green angiography is a U.S. Food and Drug Administration-approved technology used to assess tissue viability and perfusion. Its use in plastic and reconstructive surgery to assess flap perfusion in autologous breast reconstruction is relatively new. There have been no previous studies evaluating the cost-effectiveness of this new technology compared with the current practice of clinical judgment in evaluating tissue perfusion and viability in free autologous breast reconstruction in patients who have undergone mastectomy. A comprehensive literature review was performed to identify the complication rate of the most common complications with and without laser-assisted indocyanine green angiography in free autologous breast reconstruction after mastectomy. These probabilities were combined with Medicare Current Procedural Terminology provider reimbursement codes (cost) and utility estimates for common complications from a survey of 10 plastic surgeons to fit into a decision model to evaluate the cost-effectiveness of laser-assisted indocyanine green angiography. The decision model revealed a baseline cost difference of $773.66 and a 0.22 difference in the quality-adjusted life-years, yielding an incremental cost-utility ratio of $3516.64 per quality-adjusted life year favoring laser-assisted indocyanine green angiography. Sensitivity analysis showed that using laser-assisted indocyanine green angiography was more cost-effective when the complication rate without using laser-assisted indocyanine green angiography (clinical judgment alone) was 4 percent or higher. The authors' study demonstrates that laser-assisted indocyanine green angiography is a cost-effective technology under the most stringent acceptable thresholds when used in immediate free autologous breast reconstruction.

  11. Moyamoya syndrome as a risk factor for stroke in Saudi children. Novel and usual associations.

    PubMed

    Salih, Mustafa A; Murshid, Waleed R; Al-Salman, Mussaad M; Abdel-Gader, Abdel-Galil M; Al-Jarallah, Ahmed A; Alorainy, Ibrahim A; Hassan, Hamdy H; Kentab, Amal Y; Van Maldergem, Lionel; Othman, Saleh A; El-Desouki, Mahmoud I; Elgamal, Essam A

    2006-03-01

    To report on moyamoya syndrome (MMS) as a risk factor for stroke in a prospective and retrospective cohort of Saudi children. The usual and novel associations of MMS in this cohort will also be described. Children with stroke were evaluated at the Division of Pediatric Neurology at King Khalid University Hospital, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the periods July 1992 to February 2001 (retrospective study) and February 2001 to March 2003 (prospective study). Investigations for suspected cases included hemostatic assays, biochemical, and serological tests. Neuroimaging included CT, MRI, magnetic resonance angiography (MRA), single photon computerized tomography (SPECT) brain scan and conventional cerebral angiography. Moyamoya syndrome was the underlying risk factor for stroke in 6 (5.8%) of the 104 children (aged one month to 12 years). They were 4 females and 2 males. Their first cerebral ischemic event occurred at a mean age of 45 months (median = 44 months, range 17-66 months). In all 6 cases, MMS was associated with an underlying hematologic abnormality or other diseases. Protein C deficiency was identified in one girl and protein S deficiency in another. Two patients had respectively, sickle cell disease (SCD) and sickle cell-beta-thalassemia (S beta-thalassemia), which had been associated in the latter with membranous ventricular septal defect. Adams-Oliver syndrome (AOS, OMIM 100300) was associated with MMS in an 18-month-old girl. A 4-year-old boy had wrinkly skin syndrome (WSS, OMIM 278250) phenotype. The association of MMS and protein C deficiency was first reported in this cohort of patients, whereas the association of the syndrome with WWS and AOS has not, hitherto, been described. The 3 patients who had MMS associated with protein C deficiency, SCD, and AOS underwent successful revascularization surgery in the form of encephaloduroarteriosynangiosis. Moyamoya syndrome constitutes an important risk factor of stroke in Saudi children. Comprehensive clinical evaluation and investigations, including screening for thrombophilia and neuroimaging studies, are required for the primary diagnosis of the disease and for unraveling other diseases associated with MMS. This will help in managing these patients and in guiding genetic counseling for their families.

  12. Vertebral artery and osseous anomalies characteristic at the craniocervical junction diagnosed by CT and 3D CT angiography in normal Czech population: analysis of 511 consecutive patients.

    PubMed

    Vaněk, P; Bradáč, Ondřej; de Lacy, P; Konopková, R; Lacman, J; Beneš, V

    2017-07-01

    There are numerous indications for stabilization using instrumentation of the upper cervical spine. This area is comprised of sophisticated anatomy. There is no study describing bony and vascular anomalies of this area in the middle European population. The main aim of this study was to investigate prevalence of any vertebral artery (VA) variations and osseous anomalies in the region of the craniocervical junction in a large sample of Czech patients based on three-dimensional computed tomographic angiography (3D CTA). The VA has a variable course through C2 before it passes above its groove on the posterior arch of C1. The artery can course more medially, more posteriorly or more superiorly, thus limiting the diameter of the bony elements used as landmarks for the safe insertion of metalwork. This is known as a high-riding VA (HRVA). The VA was considered HRVA in this study if the thickness of the C2 isthmus was less than 5 mm and/or the C2 internal height was less than 2 mm and/or the width of the C2 pedicle was less than 4 mm. The prevalence of ponticulus posticus (PP) was also identified. Following the VA variations in the V3 segment of the artery were persistent first intersegmental artery (FIA), fenestration (FEN) of the VA, and the posterior inferior cerebellar artery (PICA) branch originating from the C1/2 part of VA. Records of 511 patients from our institution were analyzed. The mean age of the patients was 63.6 years. One hundred and twenty-three (24.1 %) patients were identified to have HRVA, 30 (6 %) present on both sides. The age of patient over 70 years and female sex were found to be significant risk factors for HRVA presence. The prevalence of a nearby PICA branch was 4 %, FIA was 0.4 %, and FEN was 0.2 %. The presence of PP was identified in 14.3 % of patients. The HRVA and PP are common anomalies in the Czech population, and routine preoperative high-resolution CT evaluation is mandatory to prevent the VA injury when C1-C2 instrumentation is planned. The female sex and age over 70 years were found to be the most important factors for HRVA presence. The FIA and the FEN VA were rare in our study contrary to reports published from Asia, showing as many as a 10 % the VA presence over the starting point for C1 lateral screw. On the basis of the infrequent occurrence of these anomalies, we do not recommend routine CT angiography when upper cervical spine instrumentation in the normal population is planned.

  13. Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

    PubMed Central

    2013-01-01

    We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach. PMID:23971026

  14. Non-invasive coronary angiography for patients with acute atypical chest pain discharged after negative screening including maximal negative treadmill stress test. A prospective study.

    PubMed

    Bonello, L; Armero, S; Jacquier, A; Com, O; Sarran, A; Sbragia, P; Panuel, M; Arques, S; Paganelli, F

    2009-05-01

    Among patients admitted in the emergency department for acute atypical chest pain those with an acute coronary syndrome (ACS) who are mistakenly discharged home have high mortality. A recent retrospective study has demonstrated that multislice computed tomography (MSCT) coronary angiography could improve triage of these patients. We aimed to prospectively confirm these data on patients with a negative screening including maximal treadmill stress. 30 patients discharged from the emergency department after negative screening for an ACS were included. All patients underwent MSCT angiography of the coronary artery. Patients with coronary atheroma on MSCT had an invasive coronary angiography to confirm these findings. Seven patients (23%) had obstructive coronary artery disease on MSCT. Invasive coronary angiography (ICA) confirmed the diagnosis in all patients. In patients with no previously known coronary artery disease admitted to the emergency department with atypical acute chest pain and discharged after negative screening, including maximal treadmill stress test, MSCT coronary angiography is useful for the diagnosis of obstructive coronary artery disease.

  15. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, James G.; Daily, William D.

    1994-01-01

    A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  16. 45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computerized support enforcement systems. 307.15 Section 307.15 Public Welfare Regulations Relating to Public... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.15 Approval of advance planning documents for computerized support enforcement systems. (a...

  17. Arkansas' Curriculum Guide. Competency Based Computerized Accounting.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock. Div. of Vocational, Technical and Adult Education.

    This guide contains the essential parts of a total curriculum for a one-year secondary-level course in computerized accounting. Addressed in the individual sections of the guide are the following topics: the complete accounting cycle, computer operations for accounting, computerized accounting and general ledgers, computerized accounts payable,…

  18. New insights into diabetic retinopathy by OCT angiography.

    PubMed

    Liu, Guodong; Xu, Ding; Wang, Fang

    2018-06-04

    Diabetic retinopathy (DR) is one of the most common diabetic complications, which has become a leading cause for vision loss, mainly because of macular edema and vitreous hemorrhage. Optical coherence tomography (OCT) angiography is a novel technique to visualize vascular changes including microaneurysm, non-perfusion area, intraretinal microvascular abnormalities, and neovascularization. Recently, it is possible to quantify vascular density, foveal avascular zone area, non-perfusion area objectively using OCT angiography. In addition, OCT angiography also provides an alternative method to evaluate the effect of anti-vascular endothelial growth factor (VEGF) treatments by providing high resolution images of macular microcirculatory abnormalities. Thus OCT angiography is an effective method to investigate the vascular changes of the disease, and can also be potentially applied in the diagnosis, treatment, and follow up of DR. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Indocyanine green angiography of juvenile X-linked retinoschisis.

    PubMed

    Souied, Eric H; Goritsa, Anna; Querques, Giuseppe; Coscas, Gabriel; Soubrane, Gisele

    2005-09-01

    In juvenile X-linked retinoschisis (XLRS), fluorescein angiography is usually unremarkable and contributes poorly to the diagnosis. However, indocyanine green (ICG) angiography features in eyes that are affected with XLRS were not yet described. Retrospective observational case series. A complete ophthalmologic examination that included ICG angiography was performed on three unrelated male patients (six eyes) who were 15, 22, and 48 years old. A distinct hyperfluorescent stellate pattern in the macular area that was associated with radial lines of hypofluorescence that were centered on the foveola was observed on the early phase of ICG examination (six of six eyes). This feature disappeared on the late phase of ICG examination. On these six XLRS eyes, early phases of ICG examination revealed an unusual radial aspect on the macula. This finding suggests that ICG angiography may be useful for the diagnosis of XLRS.

  20. Fairness in the coronary angiography queue.

    PubMed

    Alter, D A; Basinski, A S; Cohen, E A; Naylor, C D

    1999-10-05

    Since waiting lists for coronary angiography are generally managed without explicit queuing criteria, patients may not receive priority on the basis of clinical acuity. The objective of this study was to examine clinical and nonclinical determinants of the length of time patients wait for coronary angiography. In this single-centre prospective cohort study conducted in the autumn of 1997, 357 consecutive patients were followed from initial triage until a coronary angiography was performed or an adverse cardiac event occurred. The referring physicians' hospital affiliation (physicians at Sunnybrook & Women's College Health Sciences Centre, those who practice at another centre but perform angiography at Sunnybrook and those with no previous association with Sunnybrook) was used to compare processes of care. A clinical urgency rating scale was used to assign a recommended maximum waiting time (RMWT) to each patient retrospectively, but this was not used in the queuing process. RMWTs and actual waiting times for patients in the 3 referral groups were compared; the influence clinical and nonclinical variables had on the actual length of time patients waited for coronary angiography was assessed; and possible predictors of adverse events were examined. Of 357 patients referred to Sunnybrook, 22 (6.2%) experienced adverse events while in the queue. Among those who remained, 308 (91.9%) were in need of coronary angiography; 201 (60.0%) of those patients received one within the RMWT. The length of time to angiography was influenced by clinical characteristics similar to those specified on the urgency rating scale, leading to a moderate agreement between actual waiting times and RMWTs (kappa = 0.53). However, physician affiliation was a highly significant (p < 0.001) and independent predictor of waiting time. Whereas 45.6% of the variation in waiting time was explained by all clinical factors combined, 9.3% of the variation was explained by physician affiliation alone. Informal queuing practices for coronary angiography do reflect clinical acuity, but they are also influenced by nonclinical factors, such as the nature of the physicians' association with the catheterization facility.

  1. Pulmonary Angiography and Embolization for Severe Hemoptysis Due to Cavitary Pulmonary Tuberculosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanyika, Charles; Corr, Peter; Royston, Duncan

    1999-11-15

    Purpose: To identify the role of pulmonary angiography in the diagnosis and treatment of severe hemoptysis due to cavitary pulmonary tuberculosis. Methods: Selective pulmonary angiography was performed on eight patients with severe hemoptysis uncontrolled by previous bronchial and systemic arterial embolization. Results: Three (38%) patients had Rasmussen aneurysms, which were successfully embolized with steel coils. Five patients demonstrated pulmonary arterial hypoperfusion in the diseased lung. Conclusions: We recommend pulmonary angiography in cavitary tuberculous patients with severe hemoptysis who do not respond to systemic arterial embolization. Rasmussen aneurysms are effectively treated by steel coil occlusion.

  2. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    USGS Publications Warehouse

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  3. Business aspects of cardiovascular computed tomography: tackling the challenges.

    PubMed

    Bateman, Timothy M

    2008-01-01

    The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.

  4. 3D "spectracoustic" system: a modular, tomographic, spectroscopic mapping imaging, non-invasive, diagnostic system for detection of small starting developing tumors like melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios

    2017-03-01

    This work led to a new method named 3D spectracoustic tomographic mapping imaging. The current and the future work is related to the fabrication of a combined acoustic microscopy transducer and infrared illumination probe permitting the simultaneous acquisition of the spectroscopic and the tomographic information. This probe provides with the capability of high fidelity and precision registered information from the combined modalities named spectracoustic information.

  5. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    DTIC Science & Technology

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow...2001). 6. K. M. Tacina and W. J. A. Dahm, “Effects of heat release on turbulent shear flows, Part 1. A general equivalence principle for non-buoyant

  6. Tomographic diffractive microscopy with agile illuminations for imaging targets in a noisy background.

    PubMed

    Zhang, T; Godavarthi, C; Chaumet, P C; Maire, G; Giovannini, H; Talneau, A; Prada, C; Sentenac, A; Belkebir, K

    2015-02-15

    Tomographic diffractive microscopy is a marker-free optical digital imaging technique in which three-dimensional samples are reconstructed from a set of holograms recorded under different angles of incidence. We show experimentally that, by processing the holograms with singular value decomposition, it is possible to image objects in a noisy background that are invisible with classical wide-field microscopy and conventional tomographic reconstruction procedure. The targets can be further characterized with a selective quantitative inversion.

  7. Fusion of Three-Dimensional Echocardiographic Regional Myocardial Strain with Cardiac Computed Tomography for Noninvasive Evaluation of the Hemodynamic Impact of Coronary Stenosis in Patients with Chest Pain.

    PubMed

    Mor-Avi, Victor; Patel, Mita B; Maffessanti, Francesco; Singh, Amita; Medvedofsky, Diego; Zaidi, S Javed; Mediratta, Anuj; Narang, Akhil; Nazir, Noreen; Kachenoura, Nadjia; Lang, Roberto M; Patel, Amit R

    2018-06-01

    Combined evaluation of coronary stenosis and the extent of ischemia is essential in patients with chest pain. Intermediate-grade stenosis on computed tomographic coronary angiography (CTCA) frequently triggers downstream nuclear stress testing. Alternative approaches without stress and/or radiation may have important implications. Myocardial strain measured from echocardiographic images can be used to detect subclinical dysfunction. The authors recently tested the feasibility of fusion of three-dimensional (3D) echocardiography-derived regional resting longitudinal strain with coronary arteries from CTCA to determine the hemodynamic significance of stenosis. The aim of the present study was to validate this approach against accepted reference techniques. Seventy-eight patients with chest pain referred for CTCA who also underwent 3D echocardiography and regadenoson stress computed tomography were prospectively studied. Left ventricular longitudinal strain data (TomTec) were used to generate fused 3D displays and detect resting strain abnormalities (RSAs) in each coronary territory. Computed tomographic coronary angiographic images were interpreted for the presence and severity of stenosis. Fused 3D displays of subendocardial x-ray attenuation were created to detect stress perfusion defects (SPDs). In patients with stenosis >25% in at least one artery, fractional flow reserve was quantified (HeartFlow). RSA as a marker of significant stenosis was validated against two different combined references: stenosis >50% on CTCA and SPDs seen in the same territory (reference standard A) and fractional flow reserve < 0.80 and SPDs in the same territory (reference standard B). Of the 99 arteries with no stenosis >50% and no SPDs, considered as normal, 19 (19%) had RSAs. Conversely, with stenosis >50% and SPDs, RSAs were considerably more frequent (17 of 24 [71%]). The sensitivity, specificity, and accuracy of RSA were 0.71, 0.81, and 0.79, respectively, against reference standard A and 0.83, 0.81, and 0.82 against reference standard B. Fusion of CTCA and 3D echocardiography-derived resting myocardial strain provides combined displays, which may be useful in determination of the hemodynamic or functional impact of coronary abnormalities, without additional ionizing radiation or stress testing. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  8. Organ dose measurements from multiple-detector computed tomography using a commercial dosimetry system and tomographic, physical phantoms

    NASA Astrophysics Data System (ADS)

    Lavoie, Lindsey K.

    The technology of computed tomography (CT) imaging has soared over the last decade with the use of multi-detector CT (MDCT) scanners that are capable of performing studies in a matter of seconds. While the diagnostic information obtained from MDCT imaging is extremely valuable, it is important to ensure that the radiation doses resulting from these studies are at acceptably safe levels. This research project focused on the measurement of organ doses resulting from modern MDCT scanners. A commercially-available dosimetry system was used to measure organ doses. Small dosimeters made of optically-stimulated luminescent (OSL) material were analyzed with a portable OSL reader. Detailed verification of this system was performed. Characteristics studied include energy, scatter, and angular responses; dose linearity, ability to erase the exposed dose and ability to reuse dosimeters multiple times. The results of this verification process were positive. While small correction factors needed to be applied to the dose reported by the OSL reader, these factors were small and expected. Physical, tomographic pediatric and adult phantoms were used to measure organ doses. These phantoms were developed from CT images and are composed of tissue-equivalent materials. Because the adult phantom is comprised of numerous segments, dosimeters were placed in the phantom at several organ locations, and doses to select organs were measured using three clinical protocols: pediatric craniosynostosis, adult brain perfusion and adult cardiac CT angiography (CTA). A wide-beam, 320-slice, volumetric CT scanner and a 64-slice, MDCT scanner were used for organ dose measurements. Doses ranged from 1 to 26 mGy for the pediatric protocol, 1 to 1241 mGy for the brain perfusion protocol, and 2-100 mGy for the cardiac protocol. In most cases, the doses measured on the 64-slice scanner were higher than those on the 320-slice scanner. A methodology to measure organ doses with OSL dosimeters received from CT imaging has been presented. These measurements are especially important in keeping with the ALARA (as low as reasonably achievable) principle. While diagnostic information from CT imaging is valuable and necessary, the dose to patients is always a consideration. This methodology aids in this important task. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)

  9. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    PubMed

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  10. Ultra-wide-field angiography improves the detection and classification of diabetic retinopathy.

    PubMed

    Wessel, Matthew M; Aaker, Grant D; Parlitsis, George; Cho, Minhee; D'Amico, Donald J; Kiss, Szilárd

    2012-04-01

    To evaluate patients with diabetic retinopathy using ultra-wide-field fluorescein angiography and to compare the visualized retinal pathology with that seen on an overly of conventional 7 standard field (7SF) imaging. Two hundred and eighteen eyes of 118 diabetic patients who underwent diagnostic fluorescein angiography using the Optos Optomap Panoramic 200A imaging system were included. The visualized area of the retina, retinal nonperfusion, retinal neovascularization, and panretinal photocoagulation were quantified by two independent masked graders. The respective areas identified on the ultra-wide-field fluorescein angiography image were compared with an overly of a modified 7SF image as outlined in the Early Treatment Diabetic Retinopathy Study. Ultra-wide-field fluorescein angiograms imaging, on average, demonstrated 3.2 times more total retinal surface area than 7SF. When compared with 7SF, ultra-wide-field fluorescein angiography showed 3.9 times more nonperfusion (P < 0.001), 1.9 times more neovascularization (P = 0.036), and 3.8 times more panretinal photocoagulation (P < 0.001). In 22 eyes (10%), ultra-wide-field fluorescein angiography demonstrated retinal pathology (including nonperfusion and neovascularization) not evident in an 7SF overly. Compared with conventional 7SF imaging, ultra-wide-field fluorescein angiography reveals significantly more retinal vascular pathology in patients with diabetic retinopathy. Improved retinal visualization may alter the classification of diabetic retinopathy and may therefore influence follow-up and treatment of these patients.

  11. Intraoperative bypass graft angiography: cooperation between cardiologist and surgeons in the operation room for optimal postoperative results -- is this the way for the future?

    PubMed

    Shrestha, M; Bara, C; Khaladj, N; Kamiya, H; Hagl, C; Kallenbach, K; Zhang, R; Klima, U; Haverich, A

    2007-09-01

    To confirm the quality of total arterial CABG carried out using the left internal thoracic artery (LITA) and a radial artery (RA) T-graft and distal anastomoses immediately in the OR, we developed a new technique using intraoperative graft angiography. A 5-Fr sheath is inserted in the proximal radial artery stump, through which a catheter for LITA angiography is later introduced. From July 2004 to March 2005, 23 patients underwent total arterial CABG with the T-graft and intraoperative graft angiography. On-pump CABG was performed in 22 patients and off-pump CABG in 1 patient. Mean procedure time for the angiography was 13.7 +/- 7.3 minutes, and mean fluoroscopy time was 6.2 +/- 4.6 minutes. In two patients, the RA-marginal artery side-to-side anastomosis was stenosed and had to be revised as demonstrated by graft angiography. In one patient, the RA was kinked and in another, there was a kinking of the LITA. In both cases, kinking was corrected. The remaining anastomoses were seen to have unobstructed flow with no evidence of stenosis. Intraoperative graft angiography can be performed in patients undergoing total arterial CABG. This concept of intraoperative cooperation between an interventional cardiologist and surgeons could significantly improve the operative outcome in CABG surgery.

  12. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    ERIC Educational Resources Information Center

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  13. A Randomized Controlled Trial of the "Cool Teens" CD-ROM Computerized Program for Adolescent Anxiety

    ERIC Educational Resources Information Center

    Wuthrich, Viviana M.; Rapee, Ronald M.; Cunningham, Michael J.; Lyneham, Heidi J.; Hudson, Jennifer L.; Schniering, Carolyn A.

    2012-01-01

    Objective: Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This…

  14. Combining computerized social cognitive training with neuroplasticity-based auditory training in schizophrenia.

    PubMed

    Sacks, Stephanie; Fisher, Melissa; Garrett, Coleman; Alexander, Phillip; Holland, Christine; Rose, Demian; Hooker, Christine; Vinogradov, Sophia

    2013-01-01

    Social cognitive deficits are an important treatment target in schizophrenia, but it is unclear to what degree they require specialized interventions and which specific components of behavioral interventions are effective. In this pilot study, we explored the effects of a novel computerized neuroplasticity-based auditory training delivered in conjunction with computerized social cognition training (SCT) in patients with schizophrenia. Nineteen clinically stable schizophrenia subjects performed 50 hours of computerized exercises that place implicit, increasing demands on auditory perception, plus 12 hours of computerized training in emotion identification, social perception, and theory of mind tasks. All subjects were assessed with MATRICS-recommended measures of neurocognition and social cognition, plus a measure of self-referential source memory before and after the computerized training. Subjects showed significant improvements on multiple measures of neurocognition. Additionally, subjects showed significant gains on measures of social cognition, including the MSCEIT Perceiving Emotions, MSCEIT Managing Emotions, and self-referential source memory, plus a significant decrease in positive symptoms. Computerized training of auditory processing/verbal learning in schizophrenia results in significant basic neurocognitive gains. Further, addition of computerized social cognition training results in significant gains in several social cognitive outcome measures. Computerized cognitive training that directly targets social cognitive processes can drive improvements in these crucial functions.

  15. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    PubMed

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  16. Management of seizures in the elderly: a survey of UK geriatricians.

    PubMed Central

    Stolarek, I H; Brodie, A F; Brodie, M J

    1995-01-01

    The incidence and prevalence of epilepsy increase substantially with old age. Despite this, the investigation and management of this patient population remains a grey area. Four hundred and eleven (53%) consultant geriatricians responded to a questionnaire exploring their approach to seizures in the elderly in order to establish an overview of current clinical practice. Between one and five patients presenting with seizures, predominantly aged between 75-85 years, were reviewed monthly. Seventy per cent of geriatricians undertook to investigate the patients themselves with biochemical and haematological profiles performed by most. Electroencephalography and computerized tomographic scanning were routinely requested by a quarter of responders. Only 58% would themselves initiate therapy with antiepileptic drugs, with 16% of consultants starting treatment following the first seizure, 59% after a second and 5% after a third. Phenytoin was first choice for generalized tonic-clonic seizures with carbamazepine preferred for partial seizures. If good control was not obtained, 67% would substitute another first line drug, while 27% would add in a second. Less than 3% would use the new anticonvulsants lamotrigine or vigabatrin. Sixty per cent monitored anticonvulsant concentrations in patients with poor control or suspected toxicity. A wide variability was seen in the current approach to seizures in the elderly, which reflects a lack of established practice. Epilepsy clinics for the elderly would encourage structured research into the many unanswered questions affecting the care of older people with seizures. PMID:8786590

  17. Regional model-based computerized ionospheric tomography using GPS measurements: IONOLAB-CIT

    NASA Astrophysics Data System (ADS)

    Tuna, Hakan; Arikan, Orhan; Arikan, Feza

    2015-10-01

    Three-dimensional imaging of the electron density distribution in the ionosphere is a crucial task for investigating the ionospheric effects. Dual-frequency Global Positioning System (GPS) satellite signals can be used to estimate the slant total electron content (STEC) along the propagation path between a GPS satellite and ground-based receiver station. However, the estimated GPS-STEC is very sparse and highly nonuniformly distributed for obtaining reliable 3-D electron density distributions derived from the measurements alone. Standard tomographic reconstruction techniques are not accurate or reliable enough to represent the full complexity of variable ionosphere. On the other hand, model-based electron density distributions are produced according to the general trends of ionosphere, and these distributions do not agree with measurements, especially for geomagnetically active hours. In this study, a regional 3-D electron density distribution reconstruction method, namely, IONOLAB-CIT, is proposed to assimilate GPS-STEC into physical ionospheric models. The proposed method is based on an iterative optimization framework that tracks the deviations from the ionospheric model in terms of F2 layer critical frequency and maximum ionization height resulting from the comparison of International Reference Ionosphere extended to Plasmasphere (IRI-Plas) model-generated STEC and GPS-STEC. The suggested tomography algorithm is applied successfully for the reconstruction of electron density profiles over Turkey, during quiet and disturbed hours of ionosphere using Turkish National Permanent GPS Network.

  18. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    PubMed

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  19. Compton imaging tomography for nondestructive evaluation of large multilayer aircraft components and structures

    NASA Astrophysics Data System (ADS)

    Romanov, Volodymyr; Grubsky, Victor; Zahiri, Feraidoon

    2017-02-01

    We present a novel NDT/NDE tool for non-contact, single-sided 3D inspection of aerospace components, based on Compton Imaging Tomography (CIT) technique, which is applicable to large, non-uniform, and/or multilayer structures made of composites or lightweight metals. CIT is based on the registration of Compton-scattered X-rays, and permits the reconstruction of the full 3D (tomographic) image of the inspected objects. Unlike conventional computerized tomography (CT), CIT requires only single-sided access to objects, and therefore can be applied to large structures without their disassembly. The developed tool provides accurate detection, identification, and precise 3D localizations and measurements of any possible internal and surface defects (corrosions, cracks, voids, delaminations, porosity, and inclusions), and also disbonds, core and skin defects, and intrusion of foreign fluids (e.g., fresh and salt water, oil) inside of honeycomb sandwich structures. The NDE capabilities of the system were successfully demonstrated on various aerospace structure samples provided by several major aerospace companies. Such a CIT-based tool can detect and localize individual internal defects with dimensions about 1-2 mm3, and honeycomb disbond defects less than 6 mm by 6 mm area with the variations in the thickness of the adhesive by 100 m. Current maximum scanning speed of aircraft/spacecraft structures is about 5-8 min/ft2 (50-80 min/m2).

  20. The optimal imaging strategy for patients with stable chest pain: a cost-effectiveness analysis.

    PubMed

    Genders, Tessa S S; Petersen, Steffen E; Pugliese, Francesca; Dastidar, Amardeep G; Fleischmann, Kirsten E; Nieman, Koen; Hunink, M G Myriam

    2015-04-07

    The optimal imaging strategy for patients with stable chest pain is uncertain. To determine the cost-effectiveness of different imaging strategies for patients with stable chest pain. Microsimulation state-transition model. Published literature. 60-year-old patients with a low to intermediate probability of coronary artery disease (CAD). Lifetime. The United States, the United Kingdom, and the Netherlands. Coronary computed tomography (CT) angiography, cardiac stress magnetic resonance imaging, stress single-photon emission CT, and stress echocardiography. Lifetime costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios. The strategy that maximized QALYs and was cost-effective in the United States and the Netherlands began with coronary CT angiography, continued with cardiac stress imaging if angiography found at least 50% stenosis in at least 1 coronary artery, and ended with catheter-based coronary angiography if stress imaging induced ischemia of any severity. For U.K. men, the preferred strategy was optimal medical therapy without catheter-based coronary angiography if coronary CT angiography found only moderate CAD or stress imaging induced only mild ischemia. In these strategies, stress echocardiography was consistently more effective and less expensive than other stress imaging tests. For U.K. women, the optimal strategy was stress echocardiography followed by catheter-based coronary angiography if echocardiography induced mild or moderate ischemia. Results were sensitive to changes in the probability of CAD and assumptions about false-positive results. All cardiac stress imaging tests were assumed to be available. Exercise electrocardiography was included only in a sensitivity analysis. Differences in QALYs among strategies were small. Coronary CT angiography is a cost-effective triage test for 60-year-old patients who have nonacute chest pain and a low to intermediate probability of CAD. Erasmus University Medical Center.

  1. Use of the 2.8 French Progreat microcatheter in diagnostic cerebral angiography.

    PubMed

    Griauzde, Julius; Gemmete, Joseph J; Shastri, Ravi; Pandey, Aditya S; Chaudhary, Neeraj

    2017-01-01

    Tortuous vascular anatomy poses a significant challenge to performing diagnostic cerebral angiography. To report a new cerebral angiography technique for overcoming tortuous aortic and supra-aortic anatomy using a 2.8 French (F) Progreat microcatheter (0.028 inch (internal diameter) (Terumo; Somerset, New Jersey, USA) to obtain a diagnostic cerebral angiogram. A retrospective analysis of consecutive cases undergoing diagnostic cerebral angiography at our institution between 1 January 2013 and 30 November 2015 in which a 2.8F Progreat microcatheter was used. Clinical and operative notes were reviewed and correlated with imaging. Radiologic imaging, including CT, MRI, and digital subtraction angiography, was reviewed. Neurologic, systemic, and local complications were recorded on the basis of clinical follow-up results after each angiographic examination. Events that occurred within 24 h of the angiography were considered to be complications of the procedure. Initial attempts at catheterization of the target vessel with various 4F and 5F catheters were unsuccessful owing to tortuosity, atherosclerotic disease, or occlusion of the catheter in the target vessel. Microcatheterization of the target vessel was successful in 59/62 (95%) target vessels. A diagnostic cerebral angiogram with a power injection was obtained in 59 (100%) of the successfully catheterized vessels. In one case, angiography proceeded to aneurysm coiling after over-the-wire exchange. In two cases, angiography proceeded to mechanical thrombectomy after over-the-wire exchange. No procedural complications were seen. The 2.8F Progreat microcatheter can be used to obtain a diagnostic cerebral angiogram in patients with anatomic challenges limiting catheterization by standard techniques. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Effect of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease undergoing coronary angiography.

    PubMed

    Deftereos, Spyridon; Giannopoulos, Georgios; Kossyvakis, Charalampos; Raisakis, Konstantinos; Kaoukis, Andreas; Driva, Metaxia; Ntzouvara, Olga; Panagopoulou, Vasiliki; Rentoukas, Ilias; Nikas, Dimitrios J; Pyrgakis, Vlasios; Alpert, Martin A

    2009-09-01

    The effects of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease (CAD) are unknown. The purpose of this study was to assess the comparative effects of ionic high-osmolar and non-ionic iso-osmolar radiographic contrast media on plasma markers of complement activation and apoptosis in patients with chronic CAD undergoing coronary angiography. Forty-four patients undergoing coronary angiography for chronic CAD were randomly assigned to receive the ionic high-osmolar radiographic contrast agent diatrizoate (Group A), or the non-ionic iso-osmolar contrast agent iodixanol (Group B) during angiography. Complement component 5 (C5a) and apoptotic markers sFas and sFasL were measured just prior to angiography and 1 hour after completion of angiography. Comparison of mean pre- and post-angiography plasma marker levels showed significantly greater increases in plasma levels in Group A than in Group B of C5a (29.30 +/- 5.45 ng/ml for Group A and 0.47 +/- 0.70 ng/ml for Group B (p < 0.00001), sFas (2.36 +/- 1.63 ng/ml for Group A and 0.23 +/- 0.90 ng/ml for Group B (p < 0.00001) and sFasL (14.00 +/- 5.41 pg/ml for Group A and 0.01 +/- 1.00 pg/ml for Group B (p < 0.00001). The results suggest that in patients with chronic CAD, the use of ionic high-osmolar radiographic contrast media during coronary angiography is associated with a more robust inflammatory and apoptotic milieu than that associated with the use of non-ionic iso-osmolar radiographic contrast media.

  3. Indocyanine green angiography in patients with human T cell-lymphotropic virus type 1 uveitis.

    PubMed

    Sakurai, Toshiya; Yukawa, Eiichi; Hara, Yoshiaki; Miyata, Norio; Mochizuki, Manabu

    2002-02-01

    To determine the indocyanine green (ICG) angiographic features and to evaluate the choroidal involvement of human T-cell lymphotropic virus type 1 (HTLV-1)-associated uveitis. We performed ICG angiography using scanning laser ophthalmoscopy in 54 eyes of 27 patients (8 men and 19 women) diagnosed with HTLV-1 uveitis. The patient's mean age was 51.5 years with a range of 24-65 years. The early phase of ICG angiography revealed ICG leakage from the choroidal vessels in the posterior pole, hyperfluorescent spots that which were not detected with fluorescein angiography, and small hypofluorescent lesions in the macula which most likely corresponded to microcirculatory disturbances in the choriocapillaris. We suggest that the ICG angiographic findings reflect choroidal lesions such as infiltration with leukocytes and edema. ICG angiography may provide useful information on choroidopathy in HTLV-1 uveitis.

  4. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, J.G.; Daily, W.D.

    1994-07-05

    A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  5. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    PubMed Central

    Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo

    2016-01-01

    This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041

  6. 45 CFR 310.40 - What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...

  7. A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging

    NASA Astrophysics Data System (ADS)

    Tornai, Martin P.; Bowsher, James E.; Archer, Caryl N.; Peter, Jörg; Jaszczak, Ronald J.; MacDonald, Lawrence R.; Patt, Bradley E.; Iwanczyk, Jan S.

    2003-01-01

    A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast and near chest wall. Initial emission imaging measurements with breast lesions of various uptake ratios are presented. Methods: A prototype tomograph was constructed utilizing a compact gamma camera having a field-of-view of <13×13 cm 2 with arrays of 2×2×6 mm 3 quantized NaI(Tl) scintillators coupled to position sensitive PMTs. The camera was mounted on a radially oriented support with 6 cm variable radius-of-rotation. This unit is further mounted on a goniometric cradle providing polar motion, and in turn mounted on an azimuthal rotation stage capable of indefinite vertical axis-of-rotation about the central rotation axis (RA). Initial measurements with isotopic Tc-99 m (140 keV) to evaluate the system include acquisitions with various polar tilt angles about the RA. Tomographic measurements were made of a frequency and resolution cold-rod phantom filled with aqueous Tc-99 m. Tomographic and planar measurements of 0.6 and 1.0 cm diameter fillable spheres in an available ˜950 ml hemi-ellipsoidal (uncompressed) breast phantom attached to a life-size anthropomorphic torso phantom with lesion:breast-and-body:cardiac-and-liver activity concentration ratios of 11:1:19 were compared. Various photopeak energy windows from 10-30% widths were obtained, along with a 35% scatter window below a 15% photopeak window from the list mode data. Projections with all photopeak window and camera tilt conditions were reconstructed with an ordered subsets expectation maximization (OSEM) algorithm capable of reconstructing arbitrary tomographic orbits. Results: As iteration number increased for the tomographically measured data at all polar angles, contrasts increased while signal-to-noise ratios (SNRs) decreased in the expected way with OSEM reconstruction. The rollover between contrast improvement and SNR degradation of the lesion occurred at two to three iterations. The reconstructed tomographic data yielded SNRs with or without scatter correction that were >9 times better than the planar scans. There was up to a factor of ˜2.5 increase in total primary and scatter contamination in the photopeak window with increasing tilt angle from 15° to 45°, consistent with more direct line-of-sight of myocardial and liver activity with increased camera polar angle. Conclusion: This new, ultra-compact, dedicated tomographic imaging system has the potential of providing valuable, fully 3D functional information about small, otherwise indeterminate breast lesions as an adjunct to diagnostic mammography.

  8. Validation and comparison of four models to calculate pretest probability of obstructive coronary artery disease in a Chinese population: A coronary computed tomographic angiography study.

    PubMed

    Zhou, Jia; Liu, Yujie; Huang, Lingyu; Tan, Yahang; Li, Xingchen; Zhang, Hong; Ma, Yanhe; Zhang, Ying

    We sought to compare the performance of the updated Diamond-Forrester method (UDFM), Duke clinical score (DCS), Genders clinical model (GCM) and Genders extended model (GEM) in a Chinese population referred to coronary computed tomography angiography (coronary CTA). The reliability of existing models to calculate the pretest proability (PTP) of obstructive coronary artery disease (CAD) have not been fully investigated, especially in a Chinese population. We identified 5743 consecutive patients with suspected stable CAD who underwent coronary calcium scoring (CCS) and coronary CCTA. Obstructive CAD was defined as with the presence of ≥50% diameter stenosis in coronary CTA or unassessable segments due to severe calcification. Area under the receiver operating characteristic curve (AUC), integrated discrimination improvement (IDI), net reclassification improvement (NRI) and Hosmer-Lemeshow goodness-of-fit statistic (H-L χ 2 ) were assessed to validate and compare these models. Overall, 1872 (32%) patients had obstructive CAD and 2467 (43%) had a CCS of 0. GEM demonstrated improved discrimination over the other models through the largest AUC (0.816 for GEM, 0.774 for GCM, 0.772 for DCS and 0.765 for UDFM). UDFM (-0.3255, p < 0.0001), DCS (-0.3149, p < 0.0001) and GCM (-0.2264, p < 0.0001) showed negative IDI compared to GEM. The NRI was significantly higher for GEM than the other models (0.7152, p < 0.0001, 0.5595, p < 0.0001 and 0.3195, p < 0.0001, respectively). All of the four models overestimated the prevalence of obstructive CAD, with unsatisfactory (p < 0.01 for all) calibration for UDFM (H-L χ 2  = 137.82), DCS (H-L χ 2  = 156.70), GCM (H-L χ 2  = 51.17) and GEM (H-L χ 2  = 29.67), respectively. Although GEM was superior for calculating PTP in a Chinese population referred for coronary CTA, developing new models allowing for more accurate and operational estimation are warranted. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  9. The Modification of Fluorescein Angiography and Its Applications in Age-Related Macular Degeneration and Polypoidal Choroidal Vasculopathy.

    PubMed

    Peng, Qing; Chen, Yutong; Hua, Rui

    2018-06-07

    To establish a novel retinal angiography method, red-free angiography (RFA), to investigate retinal changes in age-related macular degeneration (AMD) and polypoidal choroidal vasculopathy (PCV). Following the venous phase of fundus fluorescein angiography (FFA), the detection mode was switched to red-free reflectance to acquire RFA images using the same parameters. RFA showed subretinal fluid, polyps, and outer retinal tubulation, with a higher definition than the FFA and red-free reflectance results. The absorption coefficients in RFA provided more detailed images for AMD and PCV diagnosis. RFA is therefore a promising approach to supplement FFA. © 2018 S. Karger AG, Basel.

  10. SENSITIVITY AND SPECIFICITY OF DETECTING POLYPOIDAL CHOROIDAL VASCULOPATHY WITH EN FACE OPTICAL COHERENCE TOMOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Kokame, Gregg T; Kaneko, Kyle N; Lian, Rebecca; Lai, James C; Wee, Raymond

    2018-03-20

    Determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis with structural en face optical coherence tomography (OCT) and OCT angiography (OCTA). Retrospective review of the medical records of eyes diagnosed with PCV by indocyanine green angiography with review of diagnostic testing with structural en face OCT and OCTA by a trained reader. Structural en face OCT, cross-sectional OCT angiograms alone, and OCTA in its entirety were reviewed blinded to the findings of indocyanine green angiography and each other to determine if they could demonstrate the PCV complex. Sensitivity and specificity of PCV diagnosis was determined for each imaging technique using indocyanine green angiography as the ground truth. Sensitivity and specificity of structural en face OCT were 30.0% and 85.7%, of OCT angiograms alone were 26.8% and 96.8%, and of the entire OCTA were 43.9% and 87.1%, respectively. Sensitivity and specificity were improved for OCT angiograms and OCTA when looking at images taken within 1 month of PCV diagnosis. Sensitivity of detecting PCV was low using structural en face OCT and OCTA but specificity was high. Indocyanine green angiography remains the gold standard for PCV detection.

  11. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    PubMed

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  12. X-ray angiography systems.

    PubMed

    1993-11-01

    Despite the emergence of several alternative angiographic imaging techniques (i.e., magnetic resonance imaging, computed tomography, and ultrasound angiography), x-ray angiography remains the predominant vascular imaging modality, generating over $4 billion in revenue a year in U.S. hospitals. In this issue, we provide a brief overview of the various angiographic imaging techniques, comparing them with x-ray angiography, and discuss the clinical aspects of x-ray vascular imaging, including catheterization and clinical applications. Clinical, cost, usage, and legal issues related to contrast media are discussed in "Contrast Media: Ionic versus Nonionic and Low-osmolality Agents." We also provide a technical overview and selection guidance for a basic x-ray angiography imaging system, including the gantry and table system, x-ray generator, x-ray tube, image intensifier, video camera and display monitors, image-recording devices, and digital acquisition and processing systems. This issue also contains our Evaluation of the GE Advantx L/C cardiac angiography system and the GE Advantx AFM general-purpose angiography system; the AFM can be used for peripheral, pulmonary, and cerebral vascular studied, among others, and can also be configured for cardiac angiography. Many features of the Advantx L/C system, including generator characteristics and ease of use, also apply to the Advantx AFM as configured for cardiac angiography. Our ratings are based on the systems' ability to provide the best possible image quality for diagnosis and therapy while minimizing patient and personnel exposure to radiation, as well as its ability to minimize operator effort and inconvenience. Both units are rated Acceptable. In the Guidance Section, "Radiation Safety and Protection," we discuss the importance of keeping patient and personnel exposures to radiation as low as reasonably possible, especially in procedures such as cardiac catheterization, angiographic imaging for special procedures, and interventional radiology, which produce among the highest radiation exposure of all x-ray imaging techniques. We also provide recommendations for minimizing personnel and patient exposures to radiation. For more information about x-ray angiography systems and similar devices, as well as for additional perspectives on which we based this study, see the following Health Devices Evaluations: "Mobile C-arm Units" (19[8], August 1990) and "Noninvasive Electronic Quality Control Devices for X-ray Generator Testing" (21[6-7], June-July 1992).(ABSTRACT TRUNCATED AT 400 WORDS)

  13. Timing of angiography with a routine invasive strategy and long-term outcomes in non-ST-segment elevation acute coronary syndrome: a collaborative analysis of individual patient data from the FRISC II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) Trials.

    PubMed

    Damman, Peter; van Geloven, Nan; Wallentin, Lars; Lagerqvist, Bo; Fox, Keith A A; Clayton, Tim; Pocock, Stuart J; Hirsch, Alexander; Windhausen, Fons; Tijssen, Jan G P; de Winter, Robbert J

    2012-02-01

    This study sought to investigate long-term outcomes after early or delayed angiography in patients with non-ST-segment elevation acute coronary syndrome (nSTE-ACS) undergoing a routine invasive management. The optimal timing of angiography in patients with nSTE-ACS is currently a topic for debate. Long-term follow-up after early (within 2 days) angiography versus delayed (within 3 to 5 days) angiography was investigated in the FRISC-II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) (FIR) nSTE-ACS patient-pooled database. The main outcome was cardiovascular death or myocardial infarction up to 5-year follow-up. Hazard ratios (HR) were calculated with Cox regression models. Adjustments were made for the FIR risk score, study, and the propensity of receiving early angiography using inverse probability weighting. Of 2,721 patients originally randomized to the routine invasive arm, consisting of routine angiography and subsequent revascularization if suitable, 975 underwent early angiography and 1,141 delayed angiography. No difference was observed in 5-year cardiovascular death or myocardial infarction in unadjusted (HR: 1.06, 95% confidence interval [CI]: 0.79 to 1.42, p=0.61) and adjusted (HR: 0.93, 95% CI: 0.75 to 1.16, p=0.54) Cox regression models. In the FIR database of patients presenting with nSTE-ACS, the timing of angiography was not related to long-term cardiovascular mortality or myocardial infarction. (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes [ICTUS]; ISRCTN82153174. Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction [the Third Randomised Intervention Treatment of Angina Trials (RITA-3)]; ISRCTN07752711). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source

    PubMed Central

    Atwood, Robert C.; Bodey, Andrew J.; Price, Stephen W. T.; Basham, Mark; Drakopoulos, Michael

    2015-01-01

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an ‘orthogonal’ fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and ‘facility-independent’: it can run on standard cluster infrastructure at any institution. PMID:25939626

  15. Tomographic inversion of satellite photometry. II

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.; Hays, P. B.; Abreu, V. J.

    1985-01-01

    A method for combining nadir observations of emission features in the upper atmosphere with the result of a tomographic inversion of limb brightness measurements is presented. Simulated and actual results are provided, and error sensitivity is investigated.

  16. Mesenteric angiography

    MedlinePlus

    ... Arteriogram - abdomen; Mesenteric angiogram Images Mesenteric arteriography References Kaufman JA. Fundamentals of angiography. In: Kaufman JA, Lee MJ, eds. Vascular and Interventional Radiology: ...

  17. Stored-fluorography mode reduces radiation dose during cardiac catheterization measured with OSLD dosimeter

    NASA Astrophysics Data System (ADS)

    Ting, Chien-Yi; Chen, Zhih-Cherng; Tang, Kuo-Ting; Liu, Wei-Chung; Lin, Chun-Chih; Wang, Hsin-Ell

    2015-12-01

    Coronary angiogram is an imperative tool for diagnosis of coronary artery diseases, in which cine-angiography is a commonly used method. Although the angiography proceeds under radiation, the potential risk of radiation exposure for both the patients and the operators was seldom noticed. In this study, the absorbed radiation dose in stored-fluorography mode was compared with that in cine-angiography mode by using optically simulated luminescent dosimeters to realize their effects on radiation dose. Patients received coronary angiogram via radial artery approach were randomized into the stored-fluorography group (N=30) or the cine-angiography group (N=30). The excluded criteria were: 1. women at pregnancy or on breast feeding, 2. chronic kidney diseases with glomerular filtration rate less than 60 mL/min. During the coronary angiogram, absorbed dose of the patients and the operator radiation exposure was measured with optically simulated luminescent dosimeter (OSLD). The absorbed dose of the patients in the stored-fluorography group (3.13±0.25 mGy) was apparently lower than that in the cine-angiography group (65.57±5.37 mGy; P<0.001). For the operator, a statistical difference (P<0.001) was also found between the stored-fluorography group (0.09163 μGy) and the cine-angiography (0.6519μGy). Compared with traditional cine-angiography mode, the stored-fluorography mode can apparently reduce radiation exposure of the patients and the operator in coronary angiogram.

  18. Intraoperative Fluorescence Cerebral Angiography by Laser Surgical Microscopy: Comparison With Xenon Microscopy and Simultaneous Observation of Cerebral Blood Flow and Surrounding Structures.

    PubMed

    Ito, Yuhei; Suzuki, Kyouichi; Ichikawa, Tsuyoshi; Watanabe, Yoichi; Sato, Taku; Sakuma, Jun; Saito, Kiyoshi

    2018-06-12

    Laser surgical microscopes should enable uniform illumination of the operative field, and require less luminous energy compared with existing xenon surgical microscopes. To examine the utility of laser illumination in fluorescence cerebral angiography. Fluorescein sodium (fluorescein) was used as a fluorescent dye. We first compared the clarity of cerebral blood flow images collected by fluorescence angiography between the laser illumination and xenon illumination methods. We then assessed use of the laser illuminator for simultaneous observation of blood flow and surrounding structures during fluorescence angiography. Furthermore, the study was designed to evaluate usefulness of the thus determined excitation light in clinical cases. Fluorescence angiography using blue light laser for excitation provided higher clarity and contrast blood flow images compared with using blue light generated from a xenon lamp. Further, illumination with excitation light consisting of a combination of 3 types of laser (higher level of blue light, no green light, and lower level of red light) enabled both blood flow and surrounding structures to be observed through the microscope directly by the surgeon. Laser-illuminated fluorescence angiography provides high clarity and contrast images of cerebral blood flow. Further, a laser providing strong blue light and weak red light for excitation light enables simultaneous visual observation of fluorescent blood flow and surrounding structures by the surgeon using a surgical microscope. Overall, these data suggest that laser surgical microscopes are useful for both ordinary operative manipulations and fluorescence angiography.

  19. Acute choroidal ischemia associated with toxoplasmic retinochoroiditis.

    PubMed

    Khairallah, Moncef; Yahia, Salim Ben; Zaouali, Sonia; Jenzeri, Salah; Attia, Sonia; Messaoud, Riadh

    2007-09-01

    To describe eight patients with active toxoplasmic retinochoroiditis (RC) who had features suggestive of acute choroidal ischemia. A retrospective review of the clinical records of 23 consecutive patients with acute toxoplasmic RC was performed. All patients underwent detailed ophthalmic examination at presentation and throughout follow-up, including dilated biomicroscopic fundus examination, fundus photography, fluorescein angiography, and indocyanine green (ICG) angiography. Of 23 patients, 8 (34.8%) had a large area of retinal whitening surrounding a small focus of RC. Fluorescein as well as ICG angiography showed a well demarcated geographic area of early choroidal hypofluorescence that extended beyond the clinical borders of the white retinal lesion, particularly by ICG angiography. Associated findings for these 8 patients included old retinochoroidal scars (7 [87.5%]), serous retinal detachment (3 [37.5%]), retinal hemorrhages (1 [12.5%]), and multiple satellite dark dots by ICG angiography (6 [75%]). Seven of eight patients were treated using a combination of antitoxoplasmic drugs and corticosteroids. All findings seen at the acute stage resolved in 2 weeks to 6 weeks. A small atrophic retinochoroidal scar replaced the active toxoplasmic lesion and was surrounded with mild or moderate retinal pigment epithelium changes that were associated with decreased final visual acuity in 2 patients (25%). Patients with toxoplasmic RC may develop features suggestive of choroidal ischemia that can result in a transient or permanent decrease in vision. Choroidal ischemia can only be suspected clinically, and fluorescein angiography and ICG angiography are required to establish the definitive diagnosis.

  20. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    PubMed

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

Top