Sample records for computerized tomographic evaluation

  1. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.

  2. ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals

    DOE R&D Accomplishments Database

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.

  3. Results of the National CT Colonography Trial: Questions and Answers

    Cancer.gov

    Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.

  4. Prospective radiographic followup after en bloc ligation of the renal hilum.

    PubMed

    White, Wesley M; Klein, Frederick A; Gash, Judson; Waters, W Bedford

    2007-11-01

    We determined the risk of arteriovenous fistula after en bloc ligation of the renal hilum. A prospective evaluation of all patients who underwent en bloc ligation of the renal hilum during nephrectomy for malignant disease was performed. Pertinent operative data were recorded and patients were followed for clinical evidence of arteriovenous fistula formation, including hypertension, abdominal bruit and new onset congestive heart failure. Patients with at least 12 months of followup underwent computerized tomographic arteriography to assess arteriovenous fistula formation. A total of 94 patients underwent en bloc renal hilar ligation during open (43) and laparoscopic (51) nephrectomy using a 45 mm titanium endovascular stapler. Of this cohort 11 patients were lost to followup and 3 died of disease. The remaining 80 patients were followed an average of 35.2 months with no clinical evidence of arteriovenous fistula formation. Specifically there was no statistically significant difference in preoperative and postoperative blood pressure (p = 0.18 and 0.62, respectively), no evidence of abdominal bruit on examination and no new onset congestive heart failure. A total of 32 had increased serum creatinine and, therefore, they were excluded from followup computerized tomographic arteriography. Eight patients had a followup of less than 1 year and they were not yet eligible for evaluation. In the 40 patients who underwent computerized tomographic arteriography no fistulas were noted. Based on clinical followup and prospective radiographic evaluation there appears to be a low risk of arteriovenous fistula formation after en bloc ligation of the renal hilum using a titanium endovascular stapler.

  5. [Evaluation of the risk of mediastinal or retroperitoneal injuries caused by dorso-lumbar pedicle screws].

    PubMed

    Hernigou, P; Germany, W

    1998-09-01

    Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of metallic markers and the respect of a safe vertebral zone on X Rays could guide the choice of the appropriate screw length.

  6. The economic potential of CT scanners for hardwood sawmills

    Treesearch

    Donald G. Hodges; Walter C. Anderson; Charles W. McMillin

    1990-01-01

    Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...

  7. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    PubMed

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    PubMed

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Computerized tomography using video recorded fluoroscopic images

    NASA Technical Reports Server (NTRS)

    Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.

    1975-01-01

    A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

  10. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    PubMed

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  11. Nuclear medicine in clinical neurology: an update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldendorf, W.H.

    1981-01-01

    Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less

  12. Computerized tomography calibrator

    NASA Technical Reports Server (NTRS)

    Engel, Herbert P. (Inventor)

    1991-01-01

    A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.

  13. Computerized tomographic determination of spinal bone mineral content

    NASA Technical Reports Server (NTRS)

    Cann, C. E.; Genant, H. K.

    1980-01-01

    The aims of the study were three-fold: to determine the magnitude of vertebral cancellous mineral loss in normal subjects during bedrest, to compare this loss with calcium balance and mineral loss in peripheral bones, and to use the vertebral measurements as an evaluative criterion for the C12MDP treatment and compare it with other methods. The methods used are described and the results from 14 subjects are presented.

  14. Anthropometric and computerized tomographic measurements of lower extremity lean body mass.

    PubMed

    Buckley, D C; Kudsk, K A; Rose, B S; Fatzinger, P; Koetting, C A; Schlatter, M

    1987-02-01

    The loss of lean muscle mass is one of the hallmarks of protein-calorie malnutrition. Anthropometry is a standardized technique used to assess the response of muscle mass to nutrition therapy by quantifying the muscle and fat compartments. That technique does not accurately reflect actual limb composition, whereas computerized tomography does. Twenty lower extremities on randomly chosen men and women patients were evaluated by anthropometry and computerized tomography. Total area, muscle plus bone area, total volume, and muscle plus bone volume were correlated, using Heymsfield's equation and computerized tomography-generated areas. Anthropometrics overestimated total and muscle plus bone cross-sectional areas at almost every level. Anthropometry overestimated total area and total volume by 5% to 10% but overestimated muscle plus bone area and muscle plus bone volume by as much as 40%. Anthropometry, while easily performed and useful in large population groups for epidemiological studies, offers a poor assessment of lower extremity composition. On the other hand, computerized tomography is also easily performed and, while impractical for large population groups, does offer an accurate assessment of the lower extremity tissue compartments and is an instrument that might be used in research on lean muscle mass.

  15. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury

    PubMed Central

    Easley, R. Blaine; Mulreany, Daniel G.; Lancaster, Christopher T.; Custer, Jason W.; Fernandez-Bustamante, Ana; Colantuoni, Elizabeth; Simon, Brett A.

    2009-01-01

    Background Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. We hypothesize that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. Methods Anesthetized, mechanically ventilated canines were instrumented with PiCCO® (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computerized tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. Results Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly following endotoxin administration. Computerized tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. Conclusions The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computerized tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW. PMID:19809280

  16. Diagnosis of unsuspected facial fractures on routine head computerized tomographic scans in the unconscious multiply injured patient.

    PubMed

    Rehm, C G; Ross, S E

    1995-05-01

    This article assessed the value of routine head computerized axial tomographic (CT) scans for diagnosis of unsuspected facial fractures and its clinical implications in the multiply injured patient who is intubated, unconscious, or sedated at the time of initial assessment and requires a head CT scan to assess for brain injury. At a level I trauma center from June 1, 1992 to June 1, 1993 all intubated blunt trauma patients who required routine CT scan evaluation at initial assessment were studied prospectively. Routine scanning started at the foramen magnum and included the maxilla. Patients who died within the first 24 hours were excluded. The study population included 116 patients (85 male, 21 female) aged 12 to 85 years (mean, 28 years) with injury severity scores ranging from 1 to 50 (mean, 23). The mechanism of injury was: motor vehicle accidents (n = 74), motorcycling (n = 5), pedestrians accidents (n = 13), falls (n = 10), bicycling (n = 5), assaults (n = 8), and boating accident (n = 1). There were 19 suspected facial fractures; 18 required surgical repair. There were 27 unsuspected facial fractures; 13 required surgical care. Three suspected fractures were ruled out. Routine head CT scans to assess for brain injury in the multiply injured patient are also very useful in the diagnosis of unsuspected facial fractures, almost half of which will require surgical intervention.

  17. An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement.

    PubMed

    Zimmerman, J B; Pizer, S M; Staab, E V; Perry, J R; McCartney, W; Brenton, B C

    1988-01-01

    Adaptive histogram equalization (AHE) and intensity windowing have been compared using psychophysical observer studies. Experienced radiologists were shown clinical CT (computerized tomographic) images of the chest. Into some of the images, appropriate artificial lesions were introduced; the physicians were then shown the images processed with both AHE and intensity windowing. They were asked to assess the probability that a given image contained the artificial lesion, and their accuracy was measured. The results of these experiments show that for this particular diagnostic task, there was no significant difference in the ability of the two methods to depict luminance contrast; thus, further evaluation of AHE using controlled clinical trials is indicated.

  18. Childhood Psychosis and Computed Tomographic Brain Scan Findings.

    ERIC Educational Resources Information Center

    Gillberg, Christopher; Svendsen, Pal

    1983-01-01

    Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)

  19. Osmotic blood-brain barrier disruption. Computerized tomographic monitoring of chemotherapeutic agent delivery.

    PubMed Central

    Neuwelt, E A; Maravilla, K R; Frenkel, E P; Rapaport, S I; Hill, S A; Barnett, P A

    1979-01-01

    The present study describes a canine model of transient reversible blood-brain barrier disruption with hyperosmolar mannitol infusion into the internal carotid artery. Studies in this model show that osmotic blood-brain barrier disruption before intracarotid infusion of methotrexate results in markedly elevated (therapeutic) levels of drug in the ipsilateral cerebral hemisphere. Levels in the cerebrospinal fluid correlate poorly and inconsistently with brain levels. Computerized tomograms in this canine model provide a noninvasive monitor of the degree, time-course, and localization of osmotic blood-brain barrier disruption. Images PMID:457877

  20. CMT for biomedical and other applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spanne, P.

    This session includes two presentations describing applications for x-ray tomography using synchrotron radiation for biomedical uses and fluid flow modeling, and outlines advantages for using monoenergetic x-rays. Contrast mechanisms are briefly described and several graphs of absorbed doses and scattering of x-rays are included. Also presented are schematic diagrams of computerized tomographic instrumentation with camera head. A brief description of goals for a real time tomographic system and expected improvements to the system are described. Color photomicrographs of the Berea Sandstone and human bone are provided, as well as a 3-D microtomographic reconstruction of a human vertebra sample.

  1. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    PubMed

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  2. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    PubMed

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. CMT for materials science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinney, J.

    This session is comprised of two articles by John Kinney describing biomedical and other uses for computerized tomography. In the first article, Kinney describes the use of a three-dimensional x-ray tomographic microscope to image the trabecular bone architecture of the proximal tibias of rats in vivo. Research in this field may help to detect the earliest stages of hypoestrogenemic bone loss and may help to more rapidly test the effectiveness of new clinical treatments for this major public health problem. The second article describes recent advances in X-ray tomography using synchrotron radiation to evaluate microstructures in ceramic matrix composites, bonemore » loss in osteoporosis, and the development of carries lesions in teeth.« less

  4. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, J.H.; Bonse, U.K.; Johnson, Q.C.; Nichols, M.C.; Saroyan, R.A.; Massey, W.N.; Nusshardt, R.

    1993-09-14

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: (a) source means for providing a source of parallel x-ray beams, (b) staging means for staging and sequentially rotating a sample to be positioned in the path of the (c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, (d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and (e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor. 25 figures.

  5. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, John H.; Bonse, Ulrich K.; Johnson, Quintin C.; Nichols, Monte C.; Saroyan, Ralph A.; Massey, Warren N.; Nusshardt, Rudolph

    1993-01-01

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: a) source means for providing a source of parallel x-ray beams, b) staging means for staging and sequentially rotating a sample to be positioned in the path of the c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor.

  6. The neurologic evaluation of patients with low-tension glaucoma.

    PubMed

    Corbett, J J; Phelps, C D; Eslinger, P; Montague, P R

    1985-08-01

    One hypothesized cause of low-tension glaucoma is chronic or intermittent ischemia of the optic nerve. Since the optic nerve and brain are both parts of the central nervous system and share a common blood supply, the authors wondered if patients with low-tension glaucoma might also have clinical or radiographic evidence of cerebral atrophy. In this study, 27 patients with low-tension glaucoma were examined using neurobehavioral testing, electroencephalography, computerized tomographic scan, neurological history, and physical examination. In only a small number of patients were these tests abnormal. However, 12 of the 27 patients gave a history of common or classic migraine. This unexpected finding raises the possibility that migraine-related ischemia might be the pathogenic mechanism in some cases of low-tension glaucoma.

  7. PubMed Central

    Laplante, L; Everett, J

    1992-01-01

    Many attempts to isolate a dysfunctional site in the brain of schizophrenic patients have converged in a neuropathological conception of the disease based on frontal lobe hypoactivity. Recent data from studies using cytoarchitectony, computerized tomographic scans, cerebral regional blood flow, smooth pursuit eye movements and neuropsychological assessments are discussed. Current data on the hypofrontality hypothesis in schizophrenia seem to suggest an associationist rather than a localisationist perspective of the disorder. PMID:1489762

  8. Computed Tomography Status

    DOE R&D Accomplishments Database

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  9. Ultrafast CT scanning of an oak log for internal defects

    Treesearch

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  10. Cerebrospinal fluid flow abnormalities in patients with neoplastic meningitis. An evaluation using /sup 111/In-DTPA ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grossman, S.A.; Trump, D.L.; Chen, D.C.

    1982-11-01

    Cerebrospinal fluid flow dynamics were evaluated by /sup 111/In-diethylenetriamine pentaacetic acid (/sup 111/In-DTPA) ventriculography in 27 patients with neoplastic meningitis. Nineteen patients (70 percent) had evidence of cerebrospinal fluid flow disturbances. These occurred as ventricular outlet obstructions, abnormalities of flow in the spinal canal, or flow distrubances over the cortical convexities. Tumor histology, physical examination, cerebrospinal fluid analysis, myelograms, and computerized axial tomographic scans were not sufficient to predict cerebrospinal fluid flow patterns. These data indicate that cerebrospinal fluid flow abnormalities are common in patients with neoplastic meningitis and that /sup 111/In-DTPA cerebrospinal fluid flow imaging is useful in characterizingmore » these abnormalities. This technique provides insight into the distribution of intraventricularly administered chemotherapy and may provide explanations for treatment failure and drug-induced neurotoxicity in patients with neoplastic meningitis.« less

  11. Use of radiologic modalities in coccidioidal meningitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.

    1981-01-01

    The diagnostic utility of pentetate indium trisodium CSF studies, technetium Tc 99m brain scans, and computerized tomographic (CT) scans was evaluated in eight patients in whom coccidioidal meningitis developed following a dust storm in the Central Valley of California. The 111In flow studies and the CT scans demonstrated hydrocephalus in five patients with clinical findings suggesting this complication. Ventriculitis has not previously been diagnosed before death in patients with coccidioidal meningitis; however, it was demonstrated in two patients by the technetium Tc 99m brain scan. The finding that communicating hydrocephalus occurs early in meningitis and interferes with CSF flow intomore » infected basilar regions has important therapeutic implications in that antifungal agents injected into the lumbar subarachnoid space may not reach these regions.« less

  12. Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans

    DTIC Science & Technology

    2003-09-01

    Computerized analysis of three- dimensional reconstructed scans was also performed, based on Hounsfield unit ranges: hyperinflated, 1,000 to 900; normal...the interactive segmentation function of the software. The pulmonary parenchyma was separated into four regions based on the Hounsfield unit (HU...SII) severity. Methods: Twenty anesthetized sheep underwent graded SII: group I, no smoke; group II, 5 smoke units ; group III, 10 units ; and group IV

  13. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  14. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    PubMed

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  15. Research on ionospheric tomography based on variable pixel height

    NASA Astrophysics Data System (ADS)

    Zheng, Dunyong; Li, Peiqing; He, Jie; Hu, Wusheng; Li, Chaokui

    2016-05-01

    A novel ionospheric tomography technique based on variable pixel height was developed for the tomographic reconstruction of the ionospheric electron density distribution. The method considers the height of each pixel as an unknown variable, which is retrieved during the inversion process together with the electron density values. In contrast to conventional computerized ionospheric tomography (CIT), which parameterizes the model with a fixed pixel height, the variable-pixel-height computerized ionospheric tomography (VHCIT) model applies a disturbance to the height of each pixel. In comparison with conventional CIT models, the VHCIT technique achieved superior results in a numerical simulation. A careful validation of the reliability and superiority of VHCIT was performed. According to the results of the statistical analysis of the average root mean square errors, the proposed model offers an improvement by 15% compared with conventional CIT models.

  16. Experience with single photon emission computerized tomography (SPECT) in follow-up of sternotomy healing.

    PubMed

    Harjula, A; Järvinen, A; Mattila, S; Porkka, L

    1985-01-01

    Single photon emission computerized tomography (SPECT) was performed thrice in ten patients undergoing open-heart surgery--preoperatively and 2 and 12 weeks postoperatively. The operations were done for ischemic heart disease (5), aortic valvular stenosis (2), aortic valvular insufficiency (1), leaking mitral prosthetic valve (1) and combined aortic and mitral valvular stenosis and insufficiency (1). The healing process in the longitudinally divided sternum was evaluated from the SPECT study. Four conventional static images in two dimensions were registered in anteroposterior, posteroanterior and left and right lateral projections. A tomographic study was done. Quantitative analyses were performed. The ratio of the sternal counts to the counts from a thoracic vertebra was calculated for use as a reference. The activity ratios showed a similar pattern in six cases, with initial increases and at 12 weeks slight decrease compared with the preoperative values. In two cases the activity was still increasing after 12 postoperative weeks. One patient, with sternotomy also one year previously, showed only slightly increased activity. The activity at the areas of the sternal wires was increased in six cases. The study thus revealed differing patterns of isotope uptake, although recovery was uneventful in all patients. The differences may reflect the possibility that the operative course and the preoperative clinical status can influence the healing mechanisms.

  17. Role of CT scanning in formation evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergosh, J.L.; Dibona, B.G.

    1988-01-01

    The use of the computerized tomographic (CT) scanner in formation evaluation of difficult to analyze core samples has moved from the research and development phase to daily, routine use in the core-analysis laboratory. The role of the CT scanner has become increasingly important as geologists try to obtain more representative core material for accurate formation evaluation. The most common problem facing the core analyst when preparing to measure petrophysical properties is the selection of representative and unaltered core samples for routine and special core testing. Recent data have shown that heterogeneous reservoir rock can be very difficult, if not impossible,more » to assess correctly when using standard core examination procedures, because many features, such as fractures, are not visible on the core surface. Another problem is the invasion of drilling mud into the core sample. Flushing formation oil and water from the core can greatly alter the saturation and distribution of fluids and lead to serious formation evaluation problems. Because the quality and usefulness of the core date are directly tied to proper sample selection, it has become imperative that the CT scanner be used whenever possible.« less

  18. TomoPhantom, a software package to generate 2D-4D analytical phantoms for CT image reconstruction algorithm benchmarks

    NASA Astrophysics Data System (ADS)

    Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.

    2018-01-01

    In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.

  19. Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

    PubMed Central

    Chakravarthy, Murali; Sunilkumar, Gubbihalli; Pargaonkar, Sumant; Hosur, Rajathadri; Harivelam, Chidananda; Kavaraganahalli, Deepak; Srinivasan, Pradeep

    2015-01-01

    Objective: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. Methods: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. Results: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). Conclusion: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. PMID:25849686

  20. Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics.

    PubMed

    Silvestrini Biavati, A; Tecco, S; Migliorati, M; Festa, F; Panza, G; Marzo, G; Gherlone, E; Tetè, S

    2011-05-01

    To evaluate the maxilla, mandible, and cortical plates on computerized tomographic (CT) scans to achieve accurate three-dimensional bone thickness measurements. We selected the CT scans of 25 subjects (among 102), aged 18-58 years (10 men, 15 women), with nearly complete dentition. We performed interradicular and bucco-lingual (including cortical plate thickness) measurements in dental areas distal to the canines in both alveolar arches, at three levels (5, 8, and 11 mm) from the alveolar ridge. The mean thicknesses of the cortical plates in the maxilla were 1.10 mm buccally and 1.27 mm on the palatal side (p < 0.05). In the mandible, cortical plates were 2.23 mm buccally and 2.02 mm lingually. Mandibular buccal and lingual cortical plates became thicker distally in the second and third molar areas. There was considerable variation in cortical thickness (from 0.25 to 5.50 mm). Based on interradicular distances, only 13% of measured sites in the maxilla were suitable for miniscrew insertion (≥3.3 mm), but 63% of sites were suitable in the mandible. This study showed considerable individual variation in bone thickness. Our data suggested that the palatal/lingual side may provide greater primary stability for miniscrews. The palatal area, between the second upper bicuspid and the first molar, appeared to be the most suitable area for tapered 7- to 9-mm miniscrews, starting at 1.5-2 mm from the alveolar crest. © 2011 John Wiley & Sons A/S.

  1. NECTAR—A fission neutron radiography and tomography facility

    NASA Astrophysics Data System (ADS)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  2. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    PubMed

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  3. Volume changes of autogenous bone after sinus lifting and grafting procedures: a 6-year computerized tomographic follow-up.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Guidetti, Franco; Califano, Luigi; Bufo, Pantaleo; Sbordone, Ludovico

    2013-04-01

    To evaluate long-term bone remodelling of autografts over time (annually, for 6 years), comparing the block and particulate bone procedures for sinus floor elevation, as well as to evaluate the survival of positioned dental implants. Twenty-three sinus lift procedures with autogenous bone were performed: seven sinus lift procedures using particulate graft and 10 with block autogenous bone were performed in 17 patients. Employing a software program, pre- and post-surgical computerized tomography (CT) scans were used to compare the volume (V) and density (D) of inlay grafts over time (up to 6 years), and to determine the percentage of remaining bone (%R). All variable (V, D and %R) measurements were then compared statistically. At the 6-year survey for block form, a resorption of 21.5% was seen, whereas for particulate grafts there was a resorption of 39.2%. Both groups exhibited bone remodelling between the first and second follow-up which was significant regarding volume for the block form and regarding density for the particulate group. During the initial period of healing, the cortico-cancellous block bone grafted into the maxillary sinus underwent a negative remodelling of the volume, which is most probably due to graft cortex resorption, coupled with, primarily, an increase in density in the spongious area; for the particulate grafts, significant augmentations in density were obtained. The lack of significant differences among volumes was due to the wide degree of dispersion of the data. The rough data presented in this paper seem to support the use of a bone-block grafting procedure in maxillary sinus augmentation. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. [Imaging of temporo-mandibular disorders].

    PubMed

    Felizardo, Rufino; Foucart, Jean-Michel; Pizelle, Christophe

    2012-03-01

    Dominated for years by standard films (tomographic mouth open and mouth closed X-rays, MRI) radiographs of the TMJ have progressively lost their usefulness to diagnosticians who have progressively increased their reliance on well codified clinical examinations, which suffice in a great majority of cases.The indications for and diagnostic worth of radiological studies and the impact they have on the management of TMJ disorders are today quite low especially when the high cost of procedures like MRI, computerized tomography, and CBCT is taken into account. In this article we discuss the various maladies that dentists might encounter and the situations in which radiological examinations are still indicated. © EDP Sciences, SFODF, 2012.

  5. Effect of Sandostatin LAR on sleep apnoea in acromegaly: correlation with computerized tomographic cephalometry and hormonal activity.

    PubMed

    Ip, M S; Tan, K C; Peh, W C; Lam, K S

    2001-10-01

    Sleep apnoea has been reported to occur in subjects with acromegaly. This study evaluates the relationship among biochemical activity, sleep apnoeic activity and upper airway anatomic profile in acromegaly, and the effect of Sandostatin LAR, a long-acting somatostatin analogue, on these parameters. Fourteen subjects with acromegaly were recruited. Subjects were assessed at baseline and those with apnoea-hypopnoea index (AHI) > or = 5 were reassessed after 6 months of treatment with Sandostatin LAR 20-30 mg IMI 4-weekly. Biochemical activity was assessed with levels of GH and IGF-1. Sleep disordered breathing was assessed with overnight polysomnography. Upper airway anatomic profile was defined with computerized tomographic cephalometry. Of 14 subjects (age 42.0 +/- 8.1 years, mean +/- SD; 11 men) at baseline, there was a positive correlation between GH and tongue length (VT; P = 0.004), and between AHI and cephalometric indices: length of soft palate (PMU; P = 0.002); mandibular plane-hyoid bone distance (MPH; P = 0.017), maximum thickness of soft palate (Max-SP; P = 0.018) and VT (P = 0.027). Eight patients had sleep disordered breathing (AHI > or = 5) which was predominantly obstructive in nature (AHI = 29.4 +/- 22.6). After treatment, there were significant improvements in hormonal profile: GH, mU/l (before, 51.5 +/- 27.8; after, 8.0 +/- 7.4; P = 0.017) and IGF-1, nmol/l (before, 95.5 +/- 23.4; after, 35.0 +/- 12.4; P = 0.012); sleep-disordered breathing: AHI (before, 29.4 +/- 22.6; after, 13.4 +/- 11.12; P = 0.025), snoring episodes (before, 486 +/- 240; after, 165 +/- 170; P = 0.05); cephalometric indices, mm: MPH (before, 18.8 +/- 12.1; after, 14.8 +/- 8.4; P = 0.018), VT (before, 72.3 +/- 4.4; after, 69.7 +/- 4.3; P = 0.05). There was a positive correlation between the reduction in GH and AHI (r = 0.738, P = 0.037). The findings demonstrated that there was correlation between sleep apnoea severity and soft tissue overgrowth at the upper airway region in acromegaly. They also suggest that Sandostatin LAR improved obstructive sleep apnoea in acromegaly, and the effect might be partly mediated via a reduction in upper airway soft tissue, in particular that of the tongue, concomitant with a reduction in GH levels.

  6. Right Cardiac Chambers Involvement by a Malignant Testicular Germ Cell Tumor: An Imaging-pathologic Correlation.

    PubMed

    do Nascimento, Felipe Barjud Pereira; Albieri, Lilian; Bento Dos Santos, Glaucia Aparecida; Dolhnikoff, Marisa

    2016-07-01

    The cardiac chamber's involvement with neoplastic embolism has been rarely reported; it is mostly associated with gastric, breast, lung, liver, and prostate cancers, and usually affects the pulmonary arteries. This paper reports a case of a 31-year-old man with a malignant testicular germ cell tumor who presented with multiple episodes of pulmonary thromboembolism and died of sudden respiratory failure 1 year after the initial diagnosis. Death was attributed to massive pulmonary embolism and pulmonary infarction associated with a neoplastic thrombus that extended from the gonadal veins to pulmonary arteries. A postmortem computerized tomographic angiography and autopsy confirmed this finding. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. D-dimer threshold increase with pretest probability unlikely for pulmonary embolism to decrease unnecessary computerized tomographic pulmonary angiography

    PubMed Central

    Hogg, Melanie M.; Courtney, D. Mark; Miller, Chadwick D.; Jones, Alan E.; Smithline, Howard A

    2012-01-01

    Background Increasing the threshold to define a positive D-dimer could reduce unnecessary computed tomographic pulmonary angiography (CTPA) for suspected PE but might increase rates of missed PE and missed pneumonia, the most common nonthromboembolic diagnosis seen on CTPA. Objective Measure the effect of doubling the standard D-dimer threshold for “PE unlikely” Revised Geneva (RGS) or Wells’ scores on the exclusion rate, frequency and size of missed PE and missed pneumonia. Methods Patients evaluated for suspected PE with 64-channel CTPA were prospectively enrolled from EDs and inpatient units of four hospitals. Pretest probability data were collected in real time and the D-dimer was measured in a central laboratory. Criterion standard was CPTA interpretation by two independent radiologists combined with clinical outcome at 30 days. Results Of 678 patients enrolled, 126 (19%) were PE+ and 93 (14%) had pneumonia. Use of either Wells≤4 or RGS≤6 produced similar results. For example, with RGS≤6 and standard threshold (<500 ng/mL), D-dimer was negative in 110/678 (16%), and 4/110 were PE+ (posterior probability 3.8%), and 9/110 (8.2%) had pneumonia. With RGS≤6 and a threshold <1000 ng/mL, D-dimer was negative in 208/678 (31%) and 11/208 (5.3%) were PE+, but 10/11 missed PEs were subsegmental, and none had concomitant DVT. Pneumonia was found in 12/208 (5.4%) with RGS≤6 and D-dimer<1000 ng/mL. Conclusions Doubling the threshold for a positive D-dimer with a PE unlikely pretest probability could reduce CTPA scanning with a slightly increased risk of missed isolated subsegmental PE, and no increase in rate of missed pneumonia. PMID:22284935

  8. Evaluating a Computerized Aid for Conducting a Cognitive Task Analysis

    DTIC Science & Technology

    2000-01-01

    in conducting a cognitive task analysis . The conduct of a cognitive task analysis is costly and labor intensive. As a result, a few computerized aids...evaluation of a computerized aid, specifically CAT-HCI (Cognitive Analysis Tool - Human Computer Interface), for the conduct of a detailed cognitive task analysis . A

  9. [X-ray computed tomographic abnormalities in schizophrenia. Trial of relationship with clinical data].

    PubMed

    D'Amato, T; Rochet, T; Dalery, J; Chauchat, J H; Terra, J L; Arteaga, C; Marie-Cardine, M

    1992-01-01

    Computerized tomography (CT-scan) studies in schizophrenia revealed that some patients have neuromorphological abnormalities. The structural changes consist mainly in lateral and third ventricle enlargement, and in cortical atrophy. The present study evaluates these three changes in 42 schizophrenics aged 18 to 50, compared to 24 healthy controls. Diagnosis were established from information gathered by personal interview with the SADS-LA. Clinical sub-types were evaluated according to the DSM III-R criteria. Moreover, detailed symptoms were rated according to the Positive And Negative Syndrome Scale (PANSS). CT scans were recorded in floppy disks and blindly analyzed. Schizophrenics shown significant higher mean size of lateral and third ventricles, and higher mean anterior cortical atrophy than healthy subjects. Significant differences were also found between subtypes, with more marked abnormalities in the disorganized group. The relationship between brain abnormalities and clinical symptoms recorded with the PANSS, were analysed using Pearson correlates. Positive correlations concerned mainly negative symptoms like blunted affect, emotional withdrawal, difficulties in abstract thinking, passive apathetic social withdrawal and lack of spontaneity of conversation. Positive correlations are also observed with some symptoms classified with the PANSS in the General Psychopathology scale such as mannerism and disorientation. Negative correlation concerned most of PANSS positive symptoms.

  10. Finite element method framework for RF-based through-the-wall mapping

    NASA Astrophysics Data System (ADS)

    Campos, Rafael Saraiva; Lovisolo, Lisandro; de Campos, Marcello Luiz R.

    2017-05-01

    Radiofrequency (RF) Through-the-Wall Mapping (TWM) employs techniques originally applied in X-Ray Computerized Tomographic Imaging to map obstacles behind walls. It aims to provide valuable information for rescuing efforts in damaged buildings, as well as for military operations in urban scenarios. This work defines a Finite Element Method (FEM) based framework to allow fast and accurate simulations of the reconstruction of floors blueprints, using Ultra High-Frequency (UHF) signals at three different frequencies (500 MHz, 1 GHz and 2 GHz). To the best of our knowledge, this is the first use of FEM in a TWM scenario. This framework allows quick evaluation of different algorithms without the need to assemble a full test setup, which might not be available due to budgetary and time constraints. Using this, the present work evaluates a collection of reconstruction methods (Filtered Backprojection Reconstruction, Direct Fourier Reconstruction, Algebraic Reconstruction and Simultaneous Iterative Reconstruction) under a parallel-beam acquisition geometry for different spatial sampling rates, number of projections, antenna gains and operational frequencies. The use of multiple frequencies assesses the trade-off between higher resolution at shorter wavelengths and lower through-the-wall penetration. Considering all the drawbacks associated with such a complex problem, a robust and reliable computational setup based on a flexible method such as FEM can be very useful.

  11. Surgically Assisted Rapid Palatomaxillary Expansion With or Without Pterygomaxillary Disjunction: A Systematic Review and Meta-Analysis.

    PubMed

    Hamedi Sangsari, Adrien; Sadr-Eshkevari, Pooyan; Al-Dam, Ahmed; Friedrich, Reinhard E; Freymiller, Earl; Rashad, Ashkan

    2016-02-01

    The purpose of this review was to evaluate the outcome measurements of anterior expansion, posterior expansion, and complications after surgically assisted rapid palatal expansion (SARPE) with or without pterygomaxillary disjunction (PMD). A computerized database search was performed using PubMed, CINAHL, Cochrane, Scopus, and Web of Science. Then, a computerized search was conducted in Google Scholar and ProQuest to overcome publication bias. From the original 125 combined results, 3 met the inclusion criteria. The Quality Assessment Tool for Quantitative Studies of the Effective Public Health Practice Project assessed 2 articles as weak and 1 as moderate. The systematic review included a total of 48 patients (11 male and 37 female). For 25 patients, SARPE was performed with PMD and for 23 patients SARPE was performed without PMD. A tooth-borne fixed hyrax-type palatal expansion screw appliance was used for all cases, activated 1 to 2 mm intraoperatively, and, after a latency period of 3 to 7 days, activated 0.5 to 0.6 mm per day for 38 patients and 0.25 mm for the other 10 until adequate expansion. Postexpansion retention was performed using ligature wired hyrax in 18 patients for 4 months. Comparisons were based on cone-beam computed tomographic projections, study models only, or a combination of study models, anteroposterior cephalometric radiographs, and occlusal radiographs. The time to measure the changes ranged from before fixed orthodontic retention to 6 months after the completion of active expansion. A meta-analysis was possible only for anterior (intercanine) and posterior (inter-molar) dental expansions. The literature is inconclusive regarding the effect of PMD on the outcomes of SARPE. Further controlled trials are needed. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Successful Transarterial Embolization of a Posttraumatic Fistula Between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus: A Case Report.

    PubMed

    Jinbo, Yin; Jun, Liu; Kejie, Mou; Zheng, Zhou

    2015-01-01

    Posterior communicating artery (PCoA) aneurysm-cavernous sinus fistulae are an extremely rare complication of head injury . The treatment of PCoA aneurysm-cavernous sinus fistulae has not been well described. A 27-year-old man was admitted with a retroocular bruit and blurred vision of the left eye seven months after a severe head injury. We report the angiographic appearance of a posterior communicating artery (PCoA) aneurysm with a fistula to the cavernous sinus. This injury had been previously misinterpreted to be a PCoA aneurysm by computerized tomographic angiography (CTA). The patient was successfully treated with coils and Onyx of a fistula between the PCoA aneurysm and cavernous sinus.

  13. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  14. Tomographic imaging of OH laser-induced fluorescence in laminar and turbulent jet flames

    NASA Astrophysics Data System (ADS)

    Li, Tao; Pareja, Jhon; Fuest, Frederik; Schütte, Manuel; Zhou, Yihui; Dreizler, Andreas; Böhm, Benjamin

    2018-01-01

    In this paper a new approach for 3D flame structure diagnostics using tomographic laser-induced fluorescence (Tomo-LIF) of the OH radical was evaluated. The approach combined volumetric illumination with a multi-camera detection system of eight views. Single-shot measurements were performed in a methane/air premixed laminar flame and in a non-premixed turbulent methane jet flame. 3D OH fluorescence distributions in the flames were reconstructed using the simultaneous multiplicative algebraic reconstruction technique. The tomographic measurements were compared and validated against results of OH-PLIF in the laminar flame. The effects of the experimental setup of the detection system and the size of the volumetric illumination on the quality of the tomographic reconstructions were evaluated. Results revealed that the Tomo-LIF is suitable for volumetric reconstruction of flame structures with acceptable spatial resolution and uncertainty. It was found that the number of views and their angular orientation have a strong influence on the quality and accuracy of the tomographic reconstruction while the illumination volume thickness influences mainly the spatial resolution.

  15. A computerized tomography system for transcranial ultrasound imaging.

    PubMed

    Tang, Sai Chun; Clement, Gregory T

    Hardware for tomographic imaging presents both challenge and opportunity for simplification when compared with traditional pulse-echo imaging systems. Specifically, point diffraction tomography does not require simultaneous powering of elements, in theory allowing just a single transmit channel and a single receive channel to be coupled with a switching or multiplexing network. In our ongoing work on transcranial imaging, we have developed a 512-channel system designed to transmit and/or receive a high voltage signal from/to arbitrary elements of an imaging array. The overall design follows a hierarchy of modules including a software interface, microcontroller, pulse generator, pulse amplifier, high-voltage power converter, switching mother board, switching daughter board, receiver amplifier, analog-to-digital converter, peak detector, memory, and USB communication. Two pulse amplifiers are included, each capable of producing up to 400Vpp via power MOSFETS. Switching is based around mechanical relays that allow passage of 200V, while still achieving switching times of under 2ms, with an operating frequency ranging from below 100kHz to 10MHz. The system is demonstrated through ex vivo human skulls using 1MHz transducers. The overall system design is applicable to planned human studies in transcranial image acquisition, and may have additional tomographic applications for other materials necessitating a high signal output.

  16. Multi-dimensional distribution of near-field ionospheric disturbances produced by the 2015 Mw7.8 Nepal earthquake

    NASA Astrophysics Data System (ADS)

    Tang, Jun; Yuan, Yunbin

    2017-10-01

    Ionospheric anomalies possibly associated with large earthquakes, particularly coseismic ionospheric disturbances, have been detected by global positioning system (GPS). A large Nepal earthquake with magnitude Mw7.8 occurred on April 25, 2015. In this paper, we investigate the multi-dimensional distribution of near-field coseismic ionospheric disturbances (CIDs) using total electron content (TEC) and computerized ionospheric tomography (CIT) from regional GPS observational data. The results show significant ionospheric TEC disturbances and interesting multi-dimensional structures around the main shock. Regarding the TEC changes, coseismic ionospheric disturbances occur approximately 10-20 min after the earthquake northeast and northwest of epicentre. The maximum ridge-to-trough amplitude of CIDs is up to approximately 0.90 TECU/min. Propagation velocities of the TEC disturbances are 1.27 ± 0.06 km/s and 1.91 ± 0.38 km/s. It is believed that the ionospheric disturbances are triggered by acoustic and Rayleigh waves. Tomographic results show that the three-dimensional distribution of ionospheric disturbances obviously increases at an altitude of 300 km above the surrounding epicentre, predominantly in the entire region between 200 km and 400 km. Significant ionospheric disturbances appear at 06:30 UT from tomographic images. This study reveals characteristics of an ionospheric anomaly caused by the Nepal earthquake.

  17. Association of Brachial-Ankle Pulse Wave Velocity with Asymptomatic Intracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qain, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-08-01

    Intracranial arterial stenosis is a common cause of ischemic stroke in Asians. We therefore sought to explore the relationship of brachial-ankle pulse wave velocity and intracranial arterial stenosis in 834 stroke-free hypertensive patients. Intracranial arterial stenosis was evaluated through computerized tomographic angiography. Brachial-ankle pulse wave velocity was measured by an automated cuff device. The top decile of brachial-ankle pulse wave velocity was significantly associated with intracranial arterial stenosis (P = .027, odds ratio = 1.82; 95% confidence interval: 1.07-3.10). The patients with the top decile of brachial-ankle pulse wave velocity showed 56% higher risk for the presence of intracranial arterial stenosis to the whole population, which was more significant in patients younger than 65 years old. We also found that brachial-ankle pulse wave velocity related to both intracranial arterial stenosis and homocysteine. Our study showed the association of brachial-ankle pulse wave velocity with asymptomatic intracranial arterial stenosis in hypertension patients, especially in relative younger subjects. Brachial-ankle pulse wave velocity might be a relatively simple and repeatable measurement to detect hypertension patients in high risk of intracranial arterial stenosis. Copyright © 2016. Published by Elsevier Inc.

  18. Improving perceptions of empathy in patients undergoing low-yield computerized tomographic imaging in the emergency department.

    PubMed

    Lin, Michelle P; Probst, Marc A; Puskarich, Michael A; Dehon, Erin; Kuehl, Damon R; Wang, Ralph C; Hess, Erik P; Butler, Katie; Runyon, Michael S; Wang, Hao; Courtney, D Mark; Muckley, Brandon; Hobgood, Cherri D; Hall, Cassandra L; Kline, Jeffrey A

    2018-04-01

    We assessed emergency department (ED) patient perceptions of how physicians can improve their language to determine patient preferences for 11 phrases to enhance physician empathy toward the goal of reducing low-value advanced imaging. Multi-center survey study of low-risk ED patients undergoing computerized tomography (CT) scanning. We enroled 305 participants across nine sites. The statement "I have carefully considered what you told me about what brought you here today" was most frequently rated as important (88%). The statement "I have thought about the cost of your medical care to you today" was least frequently rated as important (59%). Participants preferred statements indicating physicians had considered their "vital signs and physical examination" (86%), "past medical history" (84%), and "what prior research tells me about your condition" (79%). Participants also valued statements conveying risks of testing, including potential kidney injury (78%) and radiation (77%). The majority of phrases were identified as important. Participants preferred statements conveying cognitive reassurance, medical knowledge and risks of testing. Our findings suggest specific phrases have the potential to enhance ED patient perceptions of physician empathy. Further research is needed to determine whether statements to convey empathy affect diagnostic testing rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of the Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) as a Measure of Treatment Effectiveness with Psychiatric Inpatients

    ERIC Educational Resources Information Center

    Kinnaman, Joanna E. Strong; Farrell, Albert D.; Bisconer, Sarah W.

    2006-01-01

    Assessment procedures to evaluate inpatient treatment effectiveness can provide information to inform clinical practice. The Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) represents a standardized approach to assess patients' target problems that combines elements of individualized and nomothetic approaches.…

  20. Computerized tomography versus magnetic resonance imaging: a comparative study in hypothalamic-pituitary and parasellar pathology.

    PubMed

    Webb, S M; Ruscalleda, J; Schwarzstein, D; Calaf-Alsina, J; Rovira, A; Matos, G; Puig-Domingo, M; de Leiva, A

    1992-05-01

    We wished to analyse the relative value of computerized tomography and magnetic resonance in patients referred for evaluation of pituitary and parasellar lesions. We performed a separate evaluation by two independent neuroradiologists of computerized tomography and magnetic resonance images ordered numerically and anonymously, with no clinical data available. We studied 40 patients submitted for hypothalamic-pituitary study; 31 were carried out preoperatively, of which histological confirmation later became available in 14. The remaining nine patients were evaluated postoperatively. Over 40 parameters relating to the bony margins, cavernous sinuses, carotid arteries, optic chiasm, suprasellar cisterns, pituitary, pituitary stalk and extension of the lesion were evaluated. These reports were compared with the initial ones offered when the scans were ordered, and with the final diagnosis. Concordance between initial computerized tomography and magnetic resonance was observed in 27 cases (67.5%); among the discordant cases computerized tomography showed the lesion in two, magnetic resonance in 10, while in the remaining case reported to harbour a microadenoma on computerized tomography the differential diagnosis between a true TSH-secreting microadenoma and pituitary resistance to thyroid hormones is still unclear. Both neuroradiologists coincided in their reports in 32 patients (80%); when the initial report was compared with those of the neuroradiologists, concordance was observed with at least one of them in 34 instances (85%). Discordant results were observed principally in microadenomas secreting ACTH or PRL and in delayed puberty. In the eight patients with Cushing's disease (histologically confirmed in six) magnetic resonance was positive in five and computerized tomography in two; the abnormal image correctly identified the side of the lesion at surgery. In patients referred for evaluation of Cushing's syndrome or hyperprolactinaemia (due to microadenomas) or after surgery, magnetic resonance is clearly preferable to computerized tomography. In macroadenomas both scans are equally diagnostic but magnetic resonance offers more information on pituitary morphology and neighbouring structures. Nevertheless, there are cases in which the results of computerized tomography and magnetic resonance will complement each other, since different parameters are analysed with each examination and discordant results are encountered.

  1. Evaluation of computerized health management information system for primary health care in rural India

    PubMed Central

    2010-01-01

    Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS), New Delhi has a computerized Health Management Information System (HMIS) since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors) and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR) 1674,217 (USD 35,622). Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213). The annual savings is around INR 894,283 (USD 11,924). Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision. PMID:21078203

  2. Enhancing GDOT's Computerized Pavement Condition Evaluation System for Pavement Condition Survey

    DOT National Transportation Integrated Search

    2017-09-01

    The Computerized Pavement Condition Evaluation System (COPACES) is a software tool that has been used by the Georgia Department of Transportation (GDOT) for its statewide pavement condition survey since the late 1990s. The previous version was releas...

  3. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  4. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).

    PubMed

    Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R

    2005-08-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.

  5. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)

    PubMed Central

    Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.

    2005-01-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670

  6. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data

    PubMed Central

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-01-01

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone. PMID:26266764

  7. A rare case of ethambutol induced pulmonary eosinophilia

    PubMed Central

    Saha, Kaushik; Bandyopadhyay, Ankan; Sengupta, Amitabha; Jash, Debraj

    2013-01-01

    Antitubercular drug (ATD) induced eosinophilic lung disease is a rare phenomenon. It usually occurs due to isoniazid and para amino salicylic acid. A 34-year-male of sputum positive pulmonary tuberculosis, on antitubercular drugs (rifampicin, isoniazid, ethambutol, and pyrazinamide) for last 3 weeks, presented with generalized arthralgia and maculopapular rash for last 2 weeks and shortness of breath for last 1 week. Chest X-ray and High resolution computerized tomographic scan thorax showed bilateral peripheral airspace opacification. Bronchoalveolar lavage revealed 51% eosinophils of total cellularity (1200/cmm) confirming the diagnosis of pulmonary eosinophilia. ATD was stopped for 2 weeks and then reintroduced one by one. Patient again developed similar kind of symptoms with reintroduction of ethambutol. According to criteria for drug induced pulmonary eosinophilia, he was diagnosed as a case of ethambutol induced pulmonary eosinophilia. PMID:24250213

  8. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data.

    PubMed

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-08-12

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone.

  9. [Computed tomographic measurement of coronary artery calcification in the assessment of cardiovascular risk: a descriptive study].

    PubMed

    Morcillo, César; Valderas, José M; Roca, Joan M; Oliveró, Ruperto; Núñez, Cristina; Sánchez, Mónica; Bechich, Siraj

    2007-03-01

    Measurement of coronary artery calcification (CAC) is used in the evaluation of cardiovascular risk. We investigated its usefulness by comparing CAC assessment with that of various risk charts. We determined cardiovascular risk in patients without known atherosclerosis using the 1998 European Task Force (ETF), REGICOR (Registre Gironí del Corazón) and SCORE (Systematic Coronary Risk Evaluation) charts. CAC was assessed by computerized tomography and measurements were classified as low risk (i.e., score <1), intermediate risk (i.e., score 1-100), or high risk (i.e., score >100). The study included 331 patients (mean age 54 [8.5] years, 89% male). In 44.1%, CAC was detected (mean score 96 [278]). The degree of agreement between the cardiovascular risk derived from the CAC score and that derived from the SCORE and ETF charts was acceptable: kappa=.33 (P<.05) and kappa=.28 (P<.05), respectively, but agreement was poor with the REGICOR chart: kappa=.02 (P=.32). The SCORE and ETF charts, respectively, classified 45.0% and 38.3% of patients with a CAC score >100 as high risk, whereas the REGICOR chart did not classify any of these patients as high risk. Male sex, older age, smoking history, and a family history of coronary heart disease were all associated with the detection of CAC. Measurement of CAC demonstrated calcification in 44.1% of patients without known atherosclerosis. By regarding those with a CAC score > 100 as high-risk, 10.4% of patients evaluated using the SCORE chart would be reclassified as high risk, as would 11.6% of those evaluated using the ETF chart, and 18.9% of those evaluated using the REGICOR chart. Consequently, more patients would be eligible for preventative treatment.

  10. Computerized Dynamic Adaptive Tests with Immediately Individualized Feedback for Primary School Mathematics Learning

    ERIC Educational Resources Information Center

    Wu, Huey-Min; Kuo, Bor-Chen; Wang, Su-Chen

    2017-01-01

    In this study, a computerized dynamic assessment test with both immediately individualized feedback and adaptively property was applied to Mathematics learning in primary school. For evaluating the effectiveness of the computerized dynamic adaptive test, the performances of three types of remedial instructions were compared by a pre-test/post-test…

  11. The Evaluation of SISMAKOM (Computerized SDI Project).

    ERIC Educational Resources Information Center

    University of Science, Penang (Malaysia).

    A survey of 88 users of SISMAKOM, a computerized selective dissemination of information (SDI) and document delivery service provided by the Universiti Sains Malaysia and four other Malaysian universities, was conducted in August 1982 in order to collect data about SISMAKOM and to assess the value of a computerized SDI service in a developing…

  12. Computerized PET/CT image analysis in the evaluation of tumour response to therapy

    PubMed Central

    Wang, J; Zhang, H H

    2015-01-01

    Current cancer therapy strategy is mostly population based, however, there are large differences in tumour response among patients. It is therefore important for treating physicians to know individual tumour response. In recent years, many studies proposed the use of computerized positron emission tomography/CT image analysis in the evaluation of tumour response. Results showed that computerized analysis overcame some major limitations of current qualitative and semiquantitative analysis and led to improved accuracy. In this review, we summarize these studies in four steps of the analysis: image registration, tumour segmentation, image feature extraction and response evaluation. Future works are proposed and challenges described. PMID:25723599

  13. Evaluating Content Alignment in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wise, Steven L.; Kingsbury, G. Gage; Webb, Norman L.

    2015-01-01

    The alignment between a test and the content domain it measures represents key evidence for the validation of test score inferences. Although procedures have been developed for evaluating the content alignment of linear tests, these procedures are not readily applicable to computerized adaptive tests (CATs), which require large item pools and do…

  14. Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.

    PubMed

    Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S

    2015-01-01

    Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.

  15. Maxillary sinusitis and periapical abscess following periodontal therapy: a case report using three-dimensional evaluation.

    PubMed

    Huang, Chih-Hao; Brunsvold, Michael A

    2006-01-01

    Maxillary sinusitis may develop from the extension of periodontal disease. In this case, reconstructed three-dimensional images from multidetector spiral computed tomographs were helpful in evaluating periodontal bony defects and their relationship with the maxillary sinus. A 42-year-old woman in good general health presented with a chronic deep periodontal pocket on the palatal and interproximal aspects of tooth #14. Probing depths of the tooth ranged from 2 to 9 mm, and it exhibited a Class 1 mobility. Radiographs revealed a close relationship between the root apex and the maxillary sinus. The patient's periodontal diagnosis was localized severe chronic periodontitis. Treatment of the tooth consisted of cause-related therapy, surgical exploration, and bone grafting. A very deep circumferential bony defect at the palatal root of tooth #14 was noted during surgery. After the operation, the wound healed without incidence, but 10 days later, a maxillary sinusitis and periapical abscess developed. To control the infection, an evaluation of sinus and alveolus using computed tomographs was performed, systemic antibiotics were prescribed, and endodontic treatment was initiated. Two weeks after surgical treatment, the infection was relieved with the help of antibiotics and endodontic treatment. Bilateral bony communications between the maxillary sinus and periodontal bony defect of maxillary first molars were shown on three-dimensional computed tomographs. The digitally reconstructed images added valuable information for evaluating the periodontal defects. Three-dimensional images from spiral computed tomographs (CT) aided in evaluating and treating the close relationship between maxillary sinus disease and adjacent periodontal defects.

  16. Computerized and Paper-and-Pencil Versions of the Rosenberg Self-Esteem Scale: A Comparison of Psychometric Features and Respondent Preferences.

    ERIC Educational Resources Information Center

    Vispoel, Walter P.; Boo, Jaeyool; Bleiler, Timothy

    2001-01-01

    Evaluated the characteristics of computerized and paper-and-pencil versions of the Rosenberg Self-Esteem Scale (SES) using scores for 224 college students. Results show that mode of administration has little effect on the psychometric properties of the SES although the computerized version took longer and was preferred by examinees. (SLD)

  17. Factors prognostic for phonetic development after cleft palate repair.

    PubMed

    Lee, Joon Seok; Kim, Jae Bong; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae; Choi, Kang Young

    2015-10-01

    Palatoplasty is aimed to achieve normal speech, improve food intake, and ensure successful maxillary growth. However, the velopharyngeal function is harder to control than other functions. Therefore, many studies on the prognostic factor of velopharyngeal insufficiency have been conducted. This study aimed to evaluate the relationships between speech outcomes and multimodality based on intraoral and preoperative three-dimensional computerized tomographic (CT) findings. Among 73 children with cleft palate who underwent palatoplasty between April 2011 and August 2014 at Kyungpook National University Hospital (KNUH), 27 were retrospectively evaluated. The 27 cases were non-syndromic, for which successful speech evaluation was conducted by a single speech-language pathologist (Table 1). Successful speech evaluation was defined as performing the test three times in 6-month intervals. Three intraoral parameters were measured before and immediately after operation (Fig. 1). On axial- and coronal-view preoperative facial CT, 5 and 2 different parameters were analyzed, respectively (Figs. 2 and 3). Regression analysis (SPSS IBM 22.0) was used in the statistical analysis. Two-flap palatoplasty and Furlow's double opposing Z-plasty were performed in 15 and 12 patients, respectively. The operation was performed 11 months after birth on average. Children with a higher palatal arch and wider maxillary tuberosity distance showed hypernasality (p < 0.05; Table 2). The useful prognostic factors of velopharyngeal function after palatoplasty were palate width and height, rather than initial diagnosis, treatment method, or palate length. Therefore, a more active intervention is needed, such as orthopedic appliance, posterior pharyngeal wall augmentation, or early speech training. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. A Computerized Library and Evaluation System for Integral Neutron Experiments.

    ERIC Educational Resources Information Center

    Hampel, Viktor E.; And Others

    A computerized library of references to integral neutron experiments has been developed at the Lawrence Radiation Laboratory at Livermore. This library serves as a data base for the systematic retrieval of documents describing diverse critical and bulk nuclear experiments. The evaluation and reduction of the physical parameters of the experiments…

  19. Development and Evaluation of Computerized Problem-based Learning Cases Emphasizing Basic Sciences Concepts.

    ERIC Educational Resources Information Center

    Abate, Marie A.; Meyer-Stout, Paula J.; Stamatakis, Mary K.; Gannett, Peter M.; Dunsworth, Teresa S.; Nardi, Anne H.

    2000-01-01

    Describes development and evaluation of eight computerized problem-based learning (PBL) cases in medicinal chemistry and pharmaceutics concepts. Case versions either incorporated concept maps emphasizing key ideas or did not. Student performance on quizzes did not differ between the different case versions and was similar to that of students who…

  20. Applications of Computer Science to the Management and Evaluation of the Educational Process.

    ERIC Educational Resources Information Center

    Hebenstreit, Jacques

    This synthesis of reports from authors representing seven different countries discusses computerization as it applies to the management and evaluation of the educational process at all levels in developed countries. Focusing on the computerization of educational administration, the first of three sections of the paper suggests that advantages of…

  1. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    PubMed

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  2. Vertical structure of medium-scale traveling ionospheric disturbances

    NASA Astrophysics Data System (ADS)

    Ssessanga, Nicholas; Kim, Yong Ha; Kim, Eunsol

    2015-11-01

    We develop an algorithm of computerized ionospheric tomography (CIT) to infer information on the vertical and horizontal structuring of electron density during nighttime medium-scale traveling ionospheric disturbances (MSTIDs). To facilitate digital CIT we have adopted total electron contents (TEC) from a dense Global Positioning System (GPS) receiver network, GEONET, which contains more than 1000 receivers. A multiplicative algebraic reconstruction technique was utilized with a calibrated IRI-2012 model as an initial solution. The reconstructed F2 peak layer varied in altitude with average peak-to-peak amplitude of ~52 km. In addition, the F2 peak layer anticorrelated with TEC variations. This feature supports a theory in which nighttime MSTID is composed of oscillating electric fields due to conductivity variations. Moreover, reconstructed TEC variations over two stations were reasonably close to variations directly derived from the measured TEC data set. Our tomographic analysis may thus help understand three-dimensional structure of MSTIDs in a quantitative way.

  3. Measurement of absolute lung volumes by imaging techniques.

    PubMed

    Clausen, J

    1997-10-01

    In this paper, the techniques available for estimating total lung capacities from standard chest radiographs in children and infants as well as adults are reviewed. These techniques include manual measurements using ellipsoid and planimetry techniques as well as computerized systems. Techniques are also available for making radiographic lung volume measurements from portable chest radiographs. There are inadequate data in the literature to support recommending one specific technique over another. Though measurements of lung volumes by radiographic, plethysmographic, gas dilution or washout techniques result in remarkably similar mean results when groups of normal subjects are tested, in patients with disease, the results of these different basic measurement techniques can differ significantly. Computed tomographic and magnetic resonance techniques can also be used to measure absolute lung volumes and offer the theoretical advantages that the results in individual subjects are less affected by variances of thoracic shape than are measurements made using conventional chest radiographs.

  4. Technical report on semiautomatic segmentation using the Adobe Photoshop.

    PubMed

    Park, Jin Seo; Chung, Min Suk; Hwang, Sung Bae; Lee, Yong Sook; Har, Dong-Hwan

    2005-12-01

    The purpose of this research is to enable users to semiautomatically segment the anatomical structures in magnetic resonance images (MRIs), computerized tomographs (CTs), and other medical images on a personal computer. The segmented images are used for making 3D images, which are helpful to medical education and research. To achieve this purpose, the following trials were performed. The entire body of a volunteer was scanned to make 557 MRIs. On Adobe Photoshop, contours of 19 anatomical structures in the MRIs were semiautomatically drawn using MAGNETIC LASSO TOOL and manually corrected using either LASSO TOOL or DIRECT SELECTION TOOL to make 557 segmented images. In a similar manner, 13 anatomical structures in 8,590 anatomical images were segmented. Proper segmentation was verified by making 3D images from the segmented images. Semiautomatic segmentation using Adobe Photoshop is expected to be widely used for segmentation of anatomical structures in various medical images.

  5. Optical coherence tomography using images of hair structure and dyes penetrating into the hair.

    PubMed

    Tsugita, Tetsuya; Iwai, Toshiaki

    2014-11-01

    Hair dyes are commonly evaluated by the appearance of the hair after dyeing. However, this approach cannot simultaneously assess how deep the dye has penetrated into hair. For simultaneous assessment of the appearance and the interior of hair, we developed a visible-range red, green, and blue (RGB) (three primary colors)-optical coherence tomography (OCT) using an RGB LED light source. We then evaluated a phantom model based on the assumption that the sample's absorbability in the vertical direction affects the tomographic imaging. Consistent with theory, our device showed higher resolution than conventional OCT with far-red light. In the experiment on the phantom model, we confirmed that the tomographic imaging is affected by absorbability unique to the sample. Furthermore, we verified that permeability can be estimated from this tomographic image. We also identified for the first time the relationship between penetration of the dye into hair and characteristics of wavelength by tomographic imaging of dyed hair. We successfully simultaneously assessed the appearance of dyed hair and inward penetration of the dye without preparing hair sections. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Laterality and Left-sidedness in the Nose, Face, and Body: A New Finding.

    PubMed

    Hafezi, Farhad; Javdani, Ali; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi

    2017-12-01

    Asymmetry is a common occurrence in bilaterian animals, particularly human beings. Through examination of patients and their photographs during rhinoplasty, we noted wider left-sided nasal and facial features in most patients. This observation led us to hypothesize that this might be consistent to the whole body. We conducted a study in 3 parts to test the question above. First, we analyzed operating notes of 50 rhinoplasty patients to determine the wider side of the upper, middle, and lower thirds of the nose. Second, we analyzed the width of the face and chest wall in 31 patients to discern any correlation between facial and bodily asymmetry. Third, computerized tomographic scans of the thorax and body of 48 patients were studied to measure the width of the hemithorax and hemipelvic bone. (1) Upper vault width was wider on left side (78%). Left middle vault width was wider (88%). The lower lateral cartilage, lateral crura convexity was more prominent on left side (48%), and a wider scroll area was found and trimmed in 21 (left) and 0 (right) cases. The alar base was wider on left side (56%). (2) In the body and face analysis, 64.5% had a wider left-sided face and body. (3) In the computed tomographic scan analysis, same-sided thorax and pelvis asymmetry was seen (85.35%), 33 and 7 of which were left- and right-sided, respectively. We observed generalized asymmetry of the face and body with left-sided predominance.

  7. Subsurface PpIX imaging in vivo with ultrasound-guided tomographic spectroscopy: reconstruction vs. born-normalized data

    NASA Astrophysics Data System (ADS)

    Flynn, Brendan P.; D'Souza, Alisha V.; Kanick, Stephen C.; Maytin, Edward; Hasan, Tayyaba; Pogue, Brian W.

    2013-03-01

    Aminolevulinic acid (ALA)-induced Protoporphyrin IX (PpIX)-based photodynamic therapy (PDT) is an effective treatment for skin cancers including basal cell carcinoma (BCC). Topically applied ALA promotes PpIX production preferentially in tumors, and many strategies have been developed to increase PpIX distribution and PDT treatment efficacy at depths > 1mm is not fully understood. While surface imaging techniques provide useful diagnosis, dosimetry, and efficacy information for superficial tumors, these methods cannot interrogate deeper tumors to provide in situ insight into spatial PpIX distributions. We have developed an ultrasound-guided, white-light-informed, tomographics spectroscopy system for the spatial measurement of subsurface PpIX. Detailed imaging system specifications, methodology, and optical-phantom-based characterization will be presented separately. Here we evaluate preliminary in vivo results using both full tomographic reconstruction and by plotting individual tomographic source-detector pair data against US images.

  8. Computerized Memory Training Leads to Sustained Improvement in Visuospatial Short-Term Memory Skills in Children with Down Syndrome

    ERIC Educational Resources Information Center

    Bennett, Stephanie J.; Holmes, Joni; Buckley, Sue

    2013-01-01

    This study evaluated the impact of a computerized visuospatial memory training intervention on the memory and behavioral skills of children with Down syndrome. Teaching assistants were trained to support the delivery of a computerized intervention program to individual children over a 10-16 week period in school. Twenty-one children aged 7-12…

  9. A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging

    NASA Astrophysics Data System (ADS)

    Tornai, Martin P.; Bowsher, James E.; Archer, Caryl N.; Peter, Jörg; Jaszczak, Ronald J.; MacDonald, Lawrence R.; Patt, Bradley E.; Iwanczyk, Jan S.

    2003-01-01

    A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast and near chest wall. Initial emission imaging measurements with breast lesions of various uptake ratios are presented. Methods: A prototype tomograph was constructed utilizing a compact gamma camera having a field-of-view of <13×13 cm 2 with arrays of 2×2×6 mm 3 quantized NaI(Tl) scintillators coupled to position sensitive PMTs. The camera was mounted on a radially oriented support with 6 cm variable radius-of-rotation. This unit is further mounted on a goniometric cradle providing polar motion, and in turn mounted on an azimuthal rotation stage capable of indefinite vertical axis-of-rotation about the central rotation axis (RA). Initial measurements with isotopic Tc-99 m (140 keV) to evaluate the system include acquisitions with various polar tilt angles about the RA. Tomographic measurements were made of a frequency and resolution cold-rod phantom filled with aqueous Tc-99 m. Tomographic and planar measurements of 0.6 and 1.0 cm diameter fillable spheres in an available ˜950 ml hemi-ellipsoidal (uncompressed) breast phantom attached to a life-size anthropomorphic torso phantom with lesion:breast-and-body:cardiac-and-liver activity concentration ratios of 11:1:19 were compared. Various photopeak energy windows from 10-30% widths were obtained, along with a 35% scatter window below a 15% photopeak window from the list mode data. Projections with all photopeak window and camera tilt conditions were reconstructed with an ordered subsets expectation maximization (OSEM) algorithm capable of reconstructing arbitrary tomographic orbits. Results: As iteration number increased for the tomographically measured data at all polar angles, contrasts increased while signal-to-noise ratios (SNRs) decreased in the expected way with OSEM reconstruction. The rollover between contrast improvement and SNR degradation of the lesion occurred at two to three iterations. The reconstructed tomographic data yielded SNRs with or without scatter correction that were >9 times better than the planar scans. There was up to a factor of ˜2.5 increase in total primary and scatter contamination in the photopeak window with increasing tilt angle from 15° to 45°, consistent with more direct line-of-sight of myocardial and liver activity with increased camera polar angle. Conclusion: This new, ultra-compact, dedicated tomographic imaging system has the potential of providing valuable, fully 3D functional information about small, otherwise indeterminate breast lesions as an adjunct to diagnostic mammography.

  10. Organ dose assessment in pediatric fluoroscopy and CT via a tomographic computational phantom of the newborn patient

    NASA Astrophysics Data System (ADS)

    Staton, Robert J.

    Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.

  11. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant apices into augmented sinus lift occurred, whereas the bone remodelling of the coronal areas was not influenced by the events in the maxillary sinus. A diameter ranging from 4 to 5 mm might better guarantee a conservation of marginal peri-implant bone level compared with implants with smaller diameters. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. [The movement computerized analysis as instrumental support for occupational doctors in evaluation of upper limb pathologies in engineering workers].

    PubMed

    D'Orso, M I; Centemeri, R; Oggionni, P; Latocca, R; Crippa, M; Vercellino, R; Riva, M; Cesana, G

    2011-01-01

    The movement computerized analysis of upper limb is a valid support in the definition of residual functional capability and of specific work suitability in complex cases. This methodology of evaluation is able to correctly and objectively define the tridimensional ranges of motion of every patient's upper limb. This fact can be particularly useful for workers coming back to work after a work-related or a not work-related accident of for handicapped workers at the beginning of a new work activity. We report a research carried out using computerized analysis of motion of upper limbs in 20 engineering workers.

  13. Evaluation of the Salt Lake City Computerized Rider Information System

    DOT National Transportation Integrated Search

    1985-11-01

    The Utah Transit Authority (UTA) Computerized Rider Information System (CRIS) project involved the installation of an automated telephone service to quickly provide bus stop-specific schedule and service information to residents throughout the Author...

  14. A computerized tree growth projection system for forest resource evaluation in the lake states

    Treesearch

    Allen L. Lundgren; Burton L. Essex

    1978-01-01

    A computerized tree growth projection system has been developed for the Lake States Region as part of a larger Forest Resources Evaluation Program (FREP). Incorporating data from more than 1500 permanent growth plots throughout the Lake States, this system projects tree growth, mortality, regeneration, and removals in stands with any mixture of tree species and sizes,...

  15. An Evaluation of Computerized Behavioral Skills Training to Teach Safety Skills to Young Children

    ERIC Educational Resources Information Center

    Vanselow, Nicholas R.; Hanley, Gregory P.

    2014-01-01

    Previous research has demonstrated the efficacy of behavioral skills training (BST) and in situ training (IST) for teaching children to protect themselves. However, BST may be resource intensive and difficult to implement on a large scale. We evaluated a computerized version of BST (CBST) to teach safety skills and determined the extent to which…

  16. Computerized Adaptive Screening Test (CAST): Development for Use in Military Recruiting Stations

    DTIC Science & Technology

    1984-01-01

    testing ( CAT ) 20. ABSTRACT (Continuo on rover .. efdo II neco .. ., ond Identity bJ’ 11/oclr -llor) The Computerized Adaptive Screening Test (CAST...effort is in progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the military entrance...U.S. Marine Corps) has been designated as lead service for CAT system development; and the Navy Personnel Research and Development Center, as lead

  17. Donor recruitment and selection for adult-to-adult living donor liver transplantation in urgent and elective circumstances.

    PubMed

    Ben-Haim, Menahem; Carmiel, Michal; Lubezky, Nir; Keidar, Rivka; Katz, Paulina; Blachar, Arye; Nimrod, Adi; Sorkine, Patrick; Oren, Ran; Klausner, Joseph M; Nakache, Richard

    2005-03-01

    Adult-to-adult living donor liver transplantation is becoming an alternative to cadaveric transplantation in urgent and elective settings. Donor selection crucially affects donor safety and recipient outcome. To present our algorithm of urgent and elective donor selection. Urgent selection is expeditious and protocol-based. Elective selection permits a comprehensive process. Both include medical, psychosocial and surgical-anatomic evaluations. Liver volumes and vascular anatomy are evaluated with computerized tomographic angiography. Informed consent is obtained after painstaking explanations. Independent institutional committees review and approve all cases. Between July 2003 and June 2004 we evaluated 43 potential live donors for 12 potential recipients (fulminant hepatic failure, n = 5; chronic end-stage liver disease, n = 6; primary graft non-function, n = 1). Thirty-three candidates (76%) were excluded due to blood type incompatibility (n = 14, 42%), incompatible anatomy (n = 8, 24%)--including problematic volume distribution (n = 2) or vascular anatomy (n = 6)--psychosocial issues (n = 4, 12%), or medical co-morbidity (n = 7, 22%). Five recipients (FHF, n = 4; chronic ESLD, n = 1) were successfully transplanted from living donors. In the acute setting, two patients (FHF, PGNF) died in the absence of an appropriate donor (cadaveric or living donor). In the elective group, one patient died of unexpected variceal bleeding and one received a cadaveric graft just before the planned living donor transplantation was performed. One candidate was transplanted overseas and two cases are scheduled. The ratio of compatibility for donation was 34% (10/29) for blood type-compatible candidates. Donor selection for living donor liver transplantation is a complex, labor-intensive multidisciplinary process. Most exclusions are due to blood type incompatibility or anatomic details. Psychosocial aspects of these donations warrant special attention.

  18. The equivalence of computerized and paper-and-pencil psychological instruments: implications for measures of negative affect.

    PubMed

    Schulenberg, S E; Yutrzenka, B A

    1999-05-01

    The use of computerized psychological assessment is a growing practice among contemporary mental health professionals. Many popular and frequently used paper-and-pencil instruments have been adapted into computerized versions. Although equivalence for many instruments has been evaluated and supported, this issue is far from resolved. This literature review deals with recent research findings that suggest that computer aversion negatively impacts computerized assessment, particularly as it relates to measures of negative affect. There is a dearth of equivalence studies that take into account computer aversion's potential impact on the measurement of negative affect. Recommendations are offered for future research in this area.

  19. Computerized symbolic manipulation in structural mechanics Progress and potential

    NASA Technical Reports Server (NTRS)

    Noor, A. K.; Andersen, C. M.

    1978-01-01

    Status and recent applications of computerized symbolic manipulation to structural mechanics problems are summarized. The applications discussed include; (1) generation of characteristic arrays of finite elements; (2) evaluation of effective stiffness and mass coefficients of continuum models for repetitive lattice structures; and (3) application of Rayleigh-Ritz technique to free vibration analysis of laminated composite elliptic plates. The major advantages of using computerized symbolic manipulation in each of these applications are outlined. A number of problem areas which limit the realization of the full potential of computerized symbolic manipulation in structural mechanics are examined and some of the means of alleviating them are discussed.

  20. Quantitative evaluation of the memory bias effect in ROC studies with PET/CT

    NASA Astrophysics Data System (ADS)

    Kallergi, Maria; Pianou, Nicoletta; Georgakopoulos, Alexandros; Kafiri, Georgia; Pavlou, Spiros; Chatziioannou, Sofia

    2012-02-01

    PURPOSE. The purpose of the study was to evaluate the memory bias effect in ROC experiments with tomographic data and, specifically, in the evaluation of two different PET/CT protocols for the detection and diagnosis of recurrent thyroid cancer. MATERIALS AND METHODS. Two readers participated in an ROC experiment that evaluated tomographic images from 43 patients followed up for thyroid cancer recurrence. Readers evaluated first whole body PET/CT scans of the patients and then a combination of whole body and high-resolution head and neck scans of the same patients. The second set was read twice. Once within 48 hours of the first set and the second time at least a month later. The detection and diagnostic performances of the readers in the three reading sessions were assessed with the DBMMRMC and LABMRMC software using the area under the ROC curve as a performance index. Performances were also evaluated by comparing the number and the size of the detected abnormal foci among the three readings. RESULTS. There was no performance difference between first and second treatments. There were statistically significant differences between first and third, and second and third treatments showing that memory can seriously affect the outcome of ROC studies. CONCLUSION. Despite the fact that tomographic data involve numerous image slices per patient, the memory bias effect is present and substantial and should be carefully eliminated from analogous ROC experiments.

  1. Association of Inter-arm Blood Pressure Difference with Asymptomatic Intracranial and Extracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-07-14

    Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24-3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309-3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study.

  2. Compton imaging tomography for nondestructive evaluation of large multilayer aircraft components and structures

    NASA Astrophysics Data System (ADS)

    Romanov, Volodymyr; Grubsky, Victor; Zahiri, Feraidoon

    2017-02-01

    We present a novel NDT/NDE tool for non-contact, single-sided 3D inspection of aerospace components, based on Compton Imaging Tomography (CIT) technique, which is applicable to large, non-uniform, and/or multilayer structures made of composites or lightweight metals. CIT is based on the registration of Compton-scattered X-rays, and permits the reconstruction of the full 3D (tomographic) image of the inspected objects. Unlike conventional computerized tomography (CT), CIT requires only single-sided access to objects, and therefore can be applied to large structures without their disassembly. The developed tool provides accurate detection, identification, and precise 3D localizations and measurements of any possible internal and surface defects (corrosions, cracks, voids, delaminations, porosity, and inclusions), and also disbonds, core and skin defects, and intrusion of foreign fluids (e.g., fresh and salt water, oil) inside of honeycomb sandwich structures. The NDE capabilities of the system were successfully demonstrated on various aerospace structure samples provided by several major aerospace companies. Such a CIT-based tool can detect and localize individual internal defects with dimensions about 1-2 mm3, and honeycomb disbond defects less than 6 mm by 6 mm area with the variations in the thickness of the adhesive by 100 m. Current maximum scanning speed of aircraft/spacecraft structures is about 5-8 min/ft2 (50-80 min/m2).

  3. Optimization of tomographic reconstruction workflows on geographically distributed resources

    DOE PAGES

    Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar; ...

    2016-01-01

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less

  4. Optimization of tomographic reconstruction workflows on geographically distributed resources

    PubMed Central

    Bicer, Tekin; Gürsoy, Doǧa; Kettimuthu, Rajkumar; De Carlo, Francesco; Foster, Ian T.

    2016-01-01

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Moreover, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks. PMID:27359149

  5. Optimization of tomographic reconstruction workflows on geographically distributed resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar

    New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less

  6. Clinical evaluation of the WOMAC 3.0 OA Index in numeric rating scale format using a computerized touch screen version.

    PubMed

    Theiler, R; Spielberger, J; Bischoff, H A; Bellamy, N; Huber, J; Kroesen, S

    2002-06-01

    The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects. The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. Copyright 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.

  7. Multitasking capacities in persons diagnosed with schizophrenia: a preliminary examination of their neurocognitive underpinnings and ability to predict real world functioning.

    PubMed

    Laloyaux, Julien; Van der Linden, Martial; Levaux, Marie-Noëlle; Mourad, Haitham; Pirri, Anthony; Bertrand, Hervé; Domken, Marc-André; Adam, Stéphane; Larøi, Frank

    2014-07-30

    Difficulties in everyday life activities are core features of persons diagnosed with schizophrenia and in particular during multitasking activities. However, at present, patients׳ multitasking capacities have not been adequately examined in the literature due to the absence of suitable assessment strategies. We thus recently developed a computerized real-life activity task designed to take into account the complex and multitasking nature of certain everyday life activities where participants are required to prepare a room for a meeting. Twenty-one individuals diagnosed with schizophrenia and 20 matched healthy controls completed the computerized task. Patients were also evaluated with a cognitive battery, measures of symptomatology and real world functioning. To examine the ecological validity, 14 other patients were recruited and were given the computerized version and a real version of the meeting preparation task. Results showed that performance on the computerized task was significantly correlated with executive functioning, pointing to the major implication of these cognitive processes in multitasking situations. Performance on the computerized task also significantly predicted up to 50% of real world functioning. Moreover, the computerized task demonstrated good ecological validity. These findings suggest the importance of evaluating multitasking capacities in patients diagnosed with schizophrenia in order to predict real world functioning. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Data-processing strategies for nano-tomography with elemental specification

    NASA Astrophysics Data System (ADS)

    Liu, Yijin; Cats, Korneel H.; Nelson Weker, Johanna; Andrews, Joy C.; Weckhuysen, Bert M.; Pianetta, Piero

    2013-10-01

    Combining the energy tunability provided by synchrotron X-ray sources with transmission X-ray microscopy, the morphology of materials can be resolved in 3D at spatial resolution down to 30 nm with elemental/chemical specification. In order to study the energy dependence of the absorption coefficient over the investigated volume, the tomographic reconstruction and image registration (before and/or after the tomographic reconstruction) are critical. We show in this paper the comparison of two different data processing strategies and conclude that the signal to noise ratio (S/N) in the final result can be improved via performing tomographic reconstruction prior to the evaluation of energy dependence. Our result echoes the dose fractionation theorem, and is particularly helpful when the element of interest has low concentration.

  9. Clinical, radiographic, ultrasonographic and computed tomographic features of nonseptic osteitis of the axial border of the proximal sesamoid bones.

    PubMed

    Vanderperren, K; Bergman, H J; Spoormakers, T J P; Pille, F; Duchateau, L; Puchalski, S M; Saunders, J H

    2014-07-01

    Lysis of the axial aspect of equine proximal sesamoid bones (PSBs) is a rare condition reported to have septic or traumatic origins. Limited information exists regarding imaging of nonseptic axial osteitis of a PSB. To report the clinical, radiographic, ultrasonographic, computed tomographic and intra-arterial contrast-enhanced computed tomographic abnormalities in horses with axial nonseptic osteitis of a PSB. Retrospective clinical study. Eighteen horses diagnosed with nonseptic osteitis of the axial border of a PSB between 2007 and 2012 were reviewed retrospectively. Case details, clinical examination, radiographic, ultrasonographic, computed tomographic and intra-arterial/intra-articular contrast-enhanced computed tomographic features were recorded, when available. Radiographic, ultrasonographic and computed tomographic evaluations of the fetlock region had been performed on 18, 15 and 9 horses, respectively. The effect of the degree of lysis on the grade and duration of lameness was determined. All horses had chronic unilateral lameness, 4 with forelimb and 14 with hindlimb signs. On radiographs, lysis was identified in both PSBs in 14 horses, one PSB in 3 horses and in one horse no lysis was identified. The degree of osteolysis was variable. Ultrasonography identified variably sized irregularities of the bone surface and alteration in echogenicity of the palmar/plantar ligament (PL). All horses undergoing computed tomographic examination (n = 9) had biaxial lysis. The lesions were significantly longer and deeper on computed tomographic images compared with radiographic images. Intra-arterial contrast-enhanced computed tomography may reveal moderate to marked contrast enhancement of the PL. There was no significant effect of the degree of lysis on the grade and duration of lameness. Lesions of nonseptic axial osteitis of a PSB can be identified using a combination of radiography and ultrasonography. Computed tomography provides additional information regarding the extent of the pathology. © 2013 EVJ Ltd.

  10. Validation of a Self-Administered Computerized System to Detect Cognitive Impairment in Older Adults

    PubMed Central

    Brinkman, Samuel D.; Reese, Robert J.; Norsworthy, Larry A.; Dellaria, Donna K.; Kinkade, Jacob W.; Benge, Jared; Brown, Kimberly; Ratka, Anna; Simpkins, James W.

    2015-01-01

    There is increasing interest in the development of economical and accurate approaches to identifying persons in the community who have mild, undetected cognitive impairments. Computerized assessment systems have been suggested as a viable approach to identifying these persons. The validity of a computerized assessment system for identification of memory and executive deficits in older individuals was evaluated in the current study. Volunteers (N = 235) completed a 3-hr battery of neuropsychological tests and a computerized cognitive assessment system. Participants were classified as impaired (n = 78) or unimpaired (n = 157) on the basis of the Mini Mental State Exam, Wechsler Memory Scale-III and the Trail Making Test (TMT), Part B. All six variables (three memory variables and three executive variables) derived from the computerized assessment differed significantly between groups in the expected direction. There was also evidence of temporal stability and concurrent validity. Application of computerized assessment systems for clinical practice and for identification of research participants is discussed in this article. PMID:25332303

  11. Contralateral decubitus positioning enhances computed tomographic angiographic evaluation of pulmonary vasculature in a patient with a pulmonary arteriovenous malformation.

    PubMed

    Tafti, Bashir Akhavan; Berenji, Gholam R; Santiago, Silverio; Barack, Bruce M

    2012-11-01

    Computed tomographic pulmonary angiography has become the diagnostic procedure of choice in patients suspected of having a pulmonary embolus. However, intrapulmonary shunting of blood in a variety of pathologic conditions can cause suboptimal opacification of the pulmonary arterial circulation and result in a suboptimal or even nondiagnostic study. Radiologists should be aware of these conditions and be familiar with positioning techniques to minimize such shunting. We report a patient suspected of having pulmonary embolism, in whom a preexisting unilateral arteriovenous malformation prevented adequate evaluation of the pulmonary circulation. Positioning the patient in the contralateral decubitus position significantly enhanced image quality.

  12. Evaluation of reconstruction errors and identification of artefacts for JET gamma and neutron tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craciunescu, Teddy, E-mail: teddy.craciunescu@jet.uk; Tiseanu, Ion; Zoita, Vasile

    The Joint European Torus (JET) neutron profile monitor ensures 2D coverage of the gamma and neutron emissive region that enables tomographic reconstruction. Due to the availability of only two projection angles and to the coarse sampling, tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET, but the problem of evaluating the errors associated with the reconstructed emissivity profile is still open. The reconstruction technique based on the maximum likelihood principle, that proved already to be a powerful tool for JET tomography, has been usedmore » to develop a method for the numerical evaluation of the statistical properties of the uncertainties in gamma and neutron emissivity reconstructions. The image covariance calculation takes into account the additional techniques introduced in the reconstruction process for tackling with the limited data set (projection resampling, smoothness regularization depending on magnetic field). The method has been validated by numerically simulations and applied to JET data. Different sources of artefacts that may significantly influence the quality of reconstructions and the accuracy of variance calculation have been identified.« less

  13. COMPUTERIZED SHAWNEE LIME/LIMESTONE SCRUBBING MODEL USERS MANUAL

    EPA Science Inventory

    The manual gives a general description of a computerized model for estimating design and cost of lime or limestone scrubber systems for flue gas desulfurization (FGD). It supplements PB80-123037 by extending the number of scrubber options which can be evaluated. It includes spray...

  14. Information technology and medication safety: what is the benefit?

    PubMed Central

    Kaushal, R; Bates, D

    2002-01-01

    

 Medication errors occur frequently and have significant clinical and financial consequences. Several types of information technologies can be used to decrease rates of medication errors. Computerized physician order entry with decision support significantly reduces serious inpatient medication error rates in adults. Other available information technologies that may prove effective for inpatients include computerized medication administration records, robots, automated pharmacy systems, bar coding, "smart" intravenous devices, and computerized discharge prescriptions and instructions. In outpatients, computerization of prescribing and patient oriented approaches such as personalized web pages and delivery of web based information may be important. Public and private mandates for information technology interventions are growing, but further development, application, evaluation, and dissemination are required. PMID:12486992

  15. Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.

    PubMed

    Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A

    2007-09-01

    Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.

  16. Evaluation of the 10th Grade Computerized Mathematics Curriculum from the Perspective of the Teachers and Educational Supervisors in the Southern Region in Jordan

    ERIC Educational Resources Information Center

    Al-Tarawneh, Sabri Hassan; Al-Qadi, Haitham Mamdouh

    2016-01-01

    This study aimed at evaluating the 10th grade computerized mathematics curriculum from the perspective of the teachers and supervisors in the southern region in Jordan. The study population consisted of all the teachers who teach the 10th grade in the southern region, with the total of (309) teachers and (20) supervisors. The sample consisted of…

  17. Studies and research concerning BNFP: computerized nuclear materials control and accounting system development evaluation report, FY 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, J M; Ehinger, M H; Joseph, C

    1978-10-01

    Development work on a computerized system for nuclear materials control and accounting in a nuclear fuel reprocessing plant is described and evaluated. Hardware and software were installed and tested to demonstrate key measurement, measurement control, and accounting requirements at accountability input/output points using natural uranium. The demonstration included a remote data acquisition system which interfaces process and special instrumentation to a cenral processing unit.

  18. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    PubMed

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  19. Evaluating the Relationship of Computer Literacy Training Competence and Nursing Experience to CPIS Resistance

    ERIC Educational Resources Information Center

    Reese, Dorothy J.

    2012-01-01

    The purpose of this quantitative, descriptive/correlational project was to examine the relationship between the level of computer literacy, informatics training, nursing experience, and perceived competence in using computerized patient information systems (CPIS) and nursing resistance to using CPIS. The Nurse Computerized Patient Information…

  20. An Evaluation of an Inquiry-Based Computer-Assisted Learning Environment.

    ERIC Educational Resources Information Center

    Maor, Dorit; Fraser, Barry

    1994-01-01

    This study focused on students' development of inquiry skills in a computerized learning environment. Seven Year-11 classes (n=120) interacted with a computerized database, "Birds of Antarctica," and curriculum materials while the teacher used an inquiry approach to learning. Students perceived their classes as more investigative and…

  1. Collaboration Scripts for Enhancing Metacognitive Self-Regulation and Mathematics Literacy

    ERIC Educational Resources Information Center

    Chen, Cheng-Huan; Chiu, Chiung-Hui

    2016-01-01

    This study designed a set of computerized collaboration scripts for multi-touch supported collaborative design-based learning and evaluated its effects on multiple aspects of metacognitive self-regulation in terms of planning and controlling and mathematical literacy achievement at higher and lower levels. The computerized scripts provided a…

  2. The Computerized Adaptive Testing System Development Project.

    ERIC Educational Resources Information Center

    McBride, James R.; Sympson, J. B.

    The Computerized Adaptive Testing (CAT) project is a joint Armed Services coordinated effort to develop and evaluate a system for automated, adaptive administration of the Armed Services Vocational Aptitude Battery (ASVAB). The CAT is a system for administering personnel tests that differs from conventional test administration in two major…

  3. Evaluation Plan for the Computerized Adaptive Vocational Aptitude Battery.

    ERIC Educational Resources Information Center

    Green, Bert F.; And Others

    The United States Armed Services are planning to introduce computerized adaptive testing (CAT) into the Armed Services Vocational Aptitude Battery (ASVAB), which is a major part of the present personnel assessment procedures. Adaptive testing will improve efficiency greatly by assessing each candidate's answers as the test progresses and posing…

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammeschlag, S.B.; Hughes, S.; O'Reilly, G.V.

    Orbital blow-out fractures were experimentally created in eight human cadavers. Each orbit underwent conventional radiographic studies, complex motion tomography, and computed tomographic examinations. A comparison of the three modalities was made. Anatomical correlation was obtained by dissecting the orbits. The significance of medial-wall fractures and enophthalmos is discussed. Limitation of inferior rectus muscle mobility is thought to be a result of muscle kinking associated with orbital fat-pad prolapse at the fracture site, rather than muscle incarceration. Blow-out fractures should be evaluated by computed tomographic computer reformations in the oblique sagittal plane.

  5. Evaluation of a Multicore-Optimized Implementation for Tomographic Reconstruction

    PubMed Central

    Agulleiro, Jose-Ignacio; Fernández, José Jesús

    2012-01-01

    Tomography allows elucidation of the three-dimensional structure of an object from a set of projection images. In life sciences, electron microscope tomography is providing invaluable information about the cell structure at a resolution of a few nanometres. Here, large images are required to combine wide fields of view with high resolution requirements. The computational complexity of the algorithms along with the large image size then turns tomographic reconstruction into a computationally demanding problem. Traditionally, high-performance computing techniques have been applied to cope with such demands on supercomputers, distributed systems and computer clusters. In the last few years, the trend has turned towards graphics processing units (GPUs). Here we present a detailed description and a thorough evaluation of an alternative approach that relies on exploitation of the power available in modern multicore computers. The combination of single-core code optimization, vector processing, multithreading and efficient disk I/O operations succeeds in providing fast tomographic reconstructions on standard computers. The approach turns out to be competitive with the fastest GPU-based solutions thus far. PMID:23139768

  6. Pressure estimation from single-snapshot tomographic PIV in a turbulent boundary layer

    NASA Astrophysics Data System (ADS)

    Schneiders, Jan F. G.; Pröbsting, Stefan; Dwight, Richard P.; van Oudheusden, Bas W.; Scarano, Fulvio

    2016-04-01

    A method is proposed to determine the instantaneous pressure field from a single tomographic PIV velocity snapshot and is applied to a flat-plate turbulent boundary layer. The main concept behind the single-snapshot pressure evaluation method is to approximate the flow acceleration using the vorticity transport equation. The vorticity field calculated from the measured instantaneous velocity is advanced over a single integration time step using the vortex-in-cell (VIC) technique to update the vorticity field, after which the temporal derivative and material derivative of velocity are evaluated. The pressure in the measurement volume is subsequently evaluated by solving a Poisson equation. The procedure is validated considering data from a turbulent boundary layer experiment, obtained with time-resolved tomographic PIV at 10 kHz, where an independent surface pressure fluctuation measurement is made by a microphone. The cross-correlation coefficient of the surface pressure fluctuations calculated by the single-snapshot pressure method with respect to the microphone measurements is calculated and compared to that obtained using time-resolved pressure-from-PIV, which is regarded as benchmark. The single-snapshot procedure returns a cross-correlation comparable to the best result obtained by time-resolved PIV, which uses a nine-point time kernel. When the kernel of the time-resolved approach is reduced to three measurements, the single-snapshot method yields approximately 30 % higher correlation. Use of the method should be cautioned when the contributions to fluctuating pressure from outside the measurement volume are significant. The study illustrates the potential for simplifying the hardware configurations (e.g. high-speed PIV or dual PIV) required to determine instantaneous pressure from tomographic PIV.

  7. Estimating crustal heterogeneity from double-difference tomography

    USGS Publications Warehouse

    Got, J.-L.; Monteiller, V.; Virieux, J.; Okubo, P.

    2006-01-01

    Seismic velocity parameters in limited, but heterogeneous volumes can be inferred using a double-difference tomographic algorithm, but to obtain meaningful results accuracy must be maintained at every step of the computation. MONTEILLER et al. (2005) have devised a double-difference tomographic algorithm that takes full advantage of the accuracy of cross-spectral time-delays of large correlated event sets. This algorithm performs an accurate computation of theoretical travel-time delays in heterogeneous media and applies a suitable inversion scheme based on optimization theory. When applied to Kilauea Volcano, in Hawaii, the double-difference tomography approach shows significant and coherent changes to the velocity model in the well-resolved volumes beneath the Kilauea caldera and the upper east rift. In this paper, we first compare the results obtained using MONTEILLER et al.'s algorithm with those obtained using the classic travel-time tomographic approach. Then, we evaluated the effect of using data series of different accuracies, such as handpicked arrival-time differences ("picking differences"), on the results produced by double-difference tomographic algorithms. We show that picking differences have a non-Gaussian probability density function (pdf). Using a hyperbolic secant pdf instead of a Gaussian pdf allows improvement of the double-difference tomographic result when using picking difference data. We completed our study by investigating the use of spatially discontinuous time-delay data. ?? Birkha??user Verlag, Basel, 2006.

  8. SimulCAT: Windows Software for Simulating Computerized Adaptive Test Administration

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2012-01-01

    Most, if not all, computerized adaptive testing (CAT) programs use simulation techniques to develop and evaluate CAT program administration and operations, but such simulation tools are rarely available to the public. Up to now, several software tools have been available to conduct CAT simulations for research purposes; however, these existing…

  9. Evaluating the Validity of Computerized Content Analysis Programs for Identification of Emotional Expression in Cancer Narratives

    ERIC Educational Resources Information Center

    Bantum, Erin O'Carroll; Owen, Jason E.

    2009-01-01

    Psychological interventions provide linguistic data that are particularly useful for testing mechanisms of action and improving intervention methodologies. For this study, emotional expression in an Internet-based intervention for women with breast cancer (n = 63) was analyzed via rater coding and 2 computerized coding methods (Linguistic Inquiry…

  10. Computerized Writing and Reading Instruction for Students in Grades 4-9 with Specific Learning Disabilities Affecting Written Language

    ERIC Educational Resources Information Center

    Tanimoto, S.; Thompson, R.; Berninger, V. W.; Nagy, W.; Abbott, R. D.

    2015-01-01

    Computer scientists and educational researchers evaluated effectiveness of computerized instruction tailored to evidence-based impairments in specific learning disabilities (SLDs) in students in grades 4-9 with persisting SLDs despite prior extra help. Following comprehensive, evidence-based differential diagnosis for dysgraphia (impaired…

  11. Exploiting Semantic Web Technologies to Develop OWL-Based Clinical Practice Guideline Execution Engines.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Abidi, Syed Sibte Raza

    2016-01-01

    Computerizing paper-based CPG and then executing them can provide evidence-informed decision support to physicians at the point of care. Semantic web technologies especially web ontology language (OWL) ontologies have been profusely used to represent computerized CPG. Using semantic web reasoning capabilities to execute OWL-based computerized CPG unties them from a specific custom-built CPG execution engine and increases their shareability as any OWL reasoner and triple store can be utilized for CPG execution. However, existing semantic web reasoning-based CPG execution engines suffer from lack of ability to execute CPG with high levels of expressivity, high cognitive load of computerization of paper-based CPG and updating their computerized versions. In order to address these limitations, we have developed three CPG execution engines based on OWL 1 DL, OWL 2 DL and OWL 2 DL + semantic web rule language (SWRL). OWL 1 DL serves as the base execution engine capable of executing a wide range of CPG constructs, however for executing highly complex CPG the OWL 2 DL and OWL 2 DL + SWRL offer additional executional capabilities. We evaluated the technical performance and medical correctness of our execution engines using a range of CPG. Technical evaluations show the efficiency of our CPG execution engines in terms of CPU time and validity of the generated recommendation in comparison to existing CPG execution engines. Medical evaluations by domain experts show the validity of the CPG-mediated therapy plans in terms of relevance, safety, and ordering for a wide range of patient scenarios.

  12. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems.

    PubMed

    Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V

    2016-01-01

    Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.

  13. Trace: a high-throughput tomographic reconstruction engine for large-scale datasets.

    PubMed

    Bicer, Tekin; Gürsoy, Doğa; Andrade, Vincent De; Kettimuthu, Rajkumar; Scullin, William; Carlo, Francesco De; Foster, Ian T

    2017-01-01

    Modern synchrotron light sources and detectors produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used imaging techniques that generates data at tens of gigabytes per second is computed tomography (CT). Although CT experiments result in rapid data generation, the analysis and reconstruction of the collected data may require hours or even days of computation time with a medium-sized workstation, which hinders the scientific progress that relies on the results of analysis. We present Trace, a data-intensive computing engine that we have developed to enable high-performance implementation of iterative tomographic reconstruction algorithms for parallel computers. Trace provides fine-grained reconstruction of tomography datasets using both (thread-level) shared memory and (process-level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations that we apply to the replicated reconstruction objects and evaluate them using tomography datasets collected at the Advanced Photon Source. Our experimental evaluations show that our optimizations and parallelization techniques can provide 158× speedup using 32 compute nodes (384 cores) over a single-core configuration and decrease the end-to-end processing time of a large sinogram (with 4501 × 1 × 22,400 dimensions) from 12.5 h to <5 min per iteration. The proposed tomographic reconstruction engine can efficiently process large-scale tomographic data using many compute nodes and minimize reconstruction times.

  14. Vestibular rehabilitation outcomes in chronic vertiginous patients through computerized dynamic visual acuity and Gaze stabilization test.

    PubMed

    Badaracco, Carlo; Labini, Francesca Sylos; Meli, Annalisa; De Angelis, Ezio; Tufarelli, Davide

    2007-09-01

    To evaluate the efficiency of the rehabilitative protocols in patients with labyrinthine hypofunction, focusing on computerized dynamic visual acuity test (DVAt) and Gaze stabilization test (GST) specifically evaluating the vestibulo-oculomotor reflex (VOR) changes due to vestibular rehabilitation. Consecutive sample study. Day hospital in Ears, Nose, and Throat Rehabilitation Unit. Thirty-two patients with chronic dizziness with a mean age of 60.74 years. Patients performed one cycle of 12 daily rehabilitation sessions (2 h each) consisting of exercises aimed at improving VOR gain. The rehabilitation program included substitutional and/or habitudinal exercises, exercises on a stability platform, and exercises on a moving footpath with rehabilitative software. Dizziness Handicap Inventory and Activities-specific Balance Confidence Scale. Computerized dynamic posturography, computerized DVAt, and GST. The patients significantly improved in all the tests. Vestibular rehabilitation improved the quality of life by reducing the handicap index and improving the ability in everyday tasks. The recovery of the vestibular-ocular reflex and vestibular-spinal reflex efficiency was objectively proven by instrumental testing. The DVAt and the GST allow to objectively quantify the fixation ability at higher frequencies and speeds (main VOR function). Moreover, these new parameters permit to completely evaluate vestibular rehabilitation outcomes, adding new information to the generally used tests that only assess vestibulospinal reflex.

  15. SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobson, D; Liu, Y

    2016-06-15

    Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes.more » The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.« less

  16. Association of conjunctival and corneal calcification with vascular calcification among hepatitis-C-seropositive hemodialysis patients.

    PubMed

    AbouSeif, Khaled; Sany, Dawlat; Elshahawy, Yasser; Seddik, Ayman; Rahman, Khedr; Gaber, Moustapha

    2016-01-01

    Disorders associated with the hepatitis C virus (HCV) have been reported including cardiovascular, metabolic, and central nervous system diseases. Since chronic HCV infections may be curable, their identification as causal contributors to cardiovascular risk could offer new perspectives in the prevention of cardiovascular disease. The aim of this study is to investigate the association between HCV and aortic arch calcification (AAC) and corneal and conjunctival calcification (CCC) in maintenance hemodialysis (MHD) patients; further, we assessed the correlation of CCC with vascular calcification. A total of 100 patients undergoing hemodialysis (HD) in our hospital were included in this study. Patients underwent a complete ocular examination including intraocular pressure, and CCC was looked for by slit lamp and fundoscopy. CCC was graded according to modified Porter and Crombie classification system described by Tokuyama et al. Helical computerized tomographic chest examination was used to evaluate the grading of AAC. Demographic, hematological, biochemical, and dialysis-related data were obtained. There was significant difference between seropositive (n = 51) and seronegative patients (n = 49) regarding grading of AAC and CCC (P <0.001). Significant positive correlation was found between grading of CCC, AAC, age (P <0.001), duration on HD (P <0.001), HCV-antibody positivity (P <0.001), serum calcium level (P <0.001), serum phosphorus level (P <0.001), calcium × phosphorus product (P <0.001), and i-parathormone level (P < 0.001). In addition, CCC grading positively correlated with AAC. Our results suggest that patients undergoing HD infected with the HCV have high degree of CCC, AAC, and mineral metabolism disorder. The strong correlation between CCC and AAC indicates that CCC evaluation is an easy, fast, non-invasive method, and might be used as an indirect indicator to detect vascular calcification in patients undergoing MHD.

  17. External and internal macromorphology in 3D-reconstructed maxillary molars using computerized X-ray microtomography.

    PubMed

    Bjørndal, L; Carlsen, O; Thuesen, G; Darvann, T; Kreiborg, S

    1999-01-01

    The aim of this study was to perform a qualitative analysis of the relationship between the external and internal macromorphology of the root complex and to use fractal dimension analysis to determine the correlation between the shape of the outer surface of the root and the shape of the root canal. On the basis of X-ray computed transaxial microtomography, a qualitative and quantitative analysis of the external and internal macromorphology of the root complex in permanent maxillary molars was performed using well-defined macromorphological variables and fractal dimension analysis. Five maxillary molars were placed between a microfocus X-ray tube with a focal spot size of 0.07 mm, a Thomson-SCF image intensifier, and a CCD camera compromising a detector for the tomograph. Between 100 and 240 tomographic 2D slices were made of each tooth. Assembling slices for 3D volume was carried out with subsequent median noise filtering. Segmentation into enamel, dentine and pulp space was achieved through thresholding followed by morphological filtering. Surface representations were then constructed. A useful visualization of the tooth was created by making the dental hard tissues transparent and the pulp chamber and root-canal system opaque. On this basis it became possible to assess the relationship between the external and internal macromorphology of the crown and root complex. There was strong agreement between the number, position and cross-section of the root canals and the number, position and degree of manifestation of the root complex macrostructures. Data from a fractal dimension analysis also showed a high correlation between the shape of the root canals and the corresponding roots. It is suggested that these types of 3D volumes constitute a platform for preclinical training in fundamental endodontic procedures.

  18. Association of Inter-arm Blood Pressure Difference with Asymptomatic Intracranial and Extracranial Arterial Stenosis in Hypertension Patients

    PubMed Central

    Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-01-01

    Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24–3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309–3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study. PMID:27412818

  19. Cost-effectiveness of Colorectal Cancer Screening and Treatment Methods: Mapping of Systematic Reviews.

    PubMed

    Abdolahi, Hossein Mashhadi; Asiabar, Ali Sarabi; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Rezapour, Aziz

    2018-01-01

    Due to extensive literature on colorectal cancer and their heterogeneous results, this study aimed to summarize the systematic reviews which review the cost-effectiveness studies on different aspects of colorectal cancer. The required data were collected by searching the following key words according to MeSH: "colorectal cancer," "colorectal oncology," "colorectal carcinoma," "colorectal neoplasm," "colorectal tumors," "cost-effectiveness," "systematic review," and "meta-analysis." The following databases were searched: PubMed, Cochrane, Google Scholar, and Scopus. Two reviewers evaluated the articles according to the checklist of "assessment of multiple systematic reviews" (AMSTAR) tool. Finally, eight systematic reviews were included in the study. The Drummond checklist was mostly used for assessing the quality of the articles. The main perspective was related to the payer and the least was relevant to the social. The majority of the cases referred to sensitivity analysis (in 76% of the cases) and the lowest point also was allocated to discounting (in 37% of cases). The Markov model was used most widely in the studies. Treatment methods examined in the studies were not cost-effective in comparison with the studied units. Among the screening methods, computerized tomographic colonography and fecal DNA were cost-effective. The average score of the articles' qualities was high (9.8 out of 11). The community perspective should be taken into consideration at large in the studies. It is necessary to pay more attention to discounting subject in studies. More frequent application of the Markov model is recommended.

  20. Evaluation of Interactive Computerized Training to Teach Parents to Implement Photographic Activity Schedules with Children with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Gerencser, Kristina R.; Higbee, Thomas S.; Akers, Jessica S.; Contreras, Bethany P.

    2017-01-01

    Training parents of children with autism spectrum disorder can be a challenge due to limited resources, time, and money. Interactive computerized training (ICT)--a self-paced program that incorporates instructions, videos, and interactive questions--is one method professionals can use to disseminate trainings to broader populations. This study…

  1. Evaluating the Effectiveness of Nurse-Focused Computerized Clinical Decision Support on Urinary Catheter Practice Guidelines

    ERIC Educational Resources Information Center

    Lang, Robin Lynn Neal

    2012-01-01

    A growing national emphasis has been placed on health information technology (HIT) with robust computerized clinical decision support (CCDS) integration into health care delivery. Catheter-associated urinary tract infection is the most frequent health care-associated infection in the United States and is associated with high cost, high volumes and…

  2. Adaptive Decision Aiding in Computer-Assisted Instruction: Adaptive Computerized Training System (ACTS).

    ERIC Educational Resources Information Center

    Hopf-Weichel, Rosemarie; And Others

    This report describes results of the first year of a three-year program to develop and evaluate a new Adaptive Computerized Training System (ACTS) for electronics maintenance training. (ACTS incorporates an adaptive computer program that learns the student's diagnostic and decision value structure, compares it to that of an expert, and adapts the…

  3. Computerized Placement Management Software (CPMS): User Manual, Version 3.0.

    ERIC Educational Resources Information Center

    College Entrance Examination Board, Princeton, NJ.

    This guide is designed to enable the beginner, as well as the advanced user, to understand and use the Computerized Placement Management Software (CPMS). The CPMS is a system for evaluating information about students and recommending their placement into courses best suited for them. It also tracks their progress and maintains their records. The…

  4. The Design and Evaluation of a Computerized Adaptive Test on Mobile Devices

    ERIC Educational Resources Information Center

    Triantafillou, Evangelos; Georgiadou, Elissavet; Economides, Anastasios A.

    2008-01-01

    The use of computerized adaptive testing (CAT) has expanded rapidly over recent years mainly due to the advances in communication and information technology. Availability of advanced mobile technologies provides several benefits to e-learning by creating an additional channel of access with mobile devices such as PDAs and mobile phones. This paper…

  5. Pressure spectra from single-snapshot tomographic PIV

    NASA Astrophysics Data System (ADS)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV and the microphone reference data. The VIC-based approach, on the other hand, returns results on the order of the reference.

  6. Image intensifier-based volume tomographic angiography imaging system: system evaluation

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Wang, Xiaohui; Shen, Jianjun; Conover, David L.

    1995-05-01

    An image intensifier-based rotational volume tomographic angiography imaging system has been constructed. The system consists of an x-ray tube and an image intensifier that are separately mounted on a gantry. This system uses an image intensifier coupled to a TV camera as a two-dimensional detector so that a set of two-dimensional projections can be acquired for a direct three-dimensional reconstruction (3D). This system has been evaluated with two phantoms: a vascular phantom and a monkey head cadaver. One hundred eighty projections of each phantom were acquired with the system. A set of three-dimensional images were directly reconstructed from the projection data. The experimental results indicate that good imaging quality can be obtained with this system.

  7. Simulated Biomass Retrieval from the Spaceborne Tomographic SAOCOM-CS Mission at L-Band

    NASA Astrophysics Data System (ADS)

    Blomberg, Erik; Soja, Maciej J.; Ferro-Famil, Laurent; Ulander, Lars M. H.; Tebaldini, Stefano

    2016-08-01

    This paper presents an evaluation of above-ground biomass (ABG) retrieval in boreal forests using simulated tomographic synthetic-aperture radar (SAR) data corresponding to the future SAOCOM-CS (L-band 1.275 GHz) mission. Using forest and radar data from the BioSAR 2008 campaign at the Krycklan test site in northern Sweden the expected performance of SAOCOM-CS is evaluated and compared with the E-SAR airborne L- band SAR (1.300 GHz). It is found that SAOCOM-CS data produce retrievals on par with those obtained with E-SAR, with retrievals having a relative RMSE of 30% or less. This holds true even if the acquisitions are limited to a single polarization, with HH results shown as an example.

  8. Computed-tomographic and conventional linear-tomographic evaluation of tracheobronchial lesions for laser photoresection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearlberg, J.L.; Sandler, M.A.; Kvale, P.

    1985-03-01

    Laser therapy is a new modality for treatment of airway lesions. The authors examined 18 patients prior to laser photoresection of tracheobronchial lesions. Thirteen had cancers involving the distal trachea, carina, and/or proximal bronchi; five had benign lesions of the middle or proximal trachea. Each patient was examined by conventional linear tomography (CLT) and computed tomography (CT). CT was valuable in patients who had lesions of the distal trachea, carina, and/or proximal bronchi. Its particular usefulness, and its advantage relative to CLT, consisted in its ability to delineate vascular structures adjacent to the planned area of photoresection. Neither CLT normore » CT was helpful in evaluation of benign lesions of the proximal trachea.« less

  9. IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices.

    PubMed

    Barngkgei, Imad; Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad

    2016-09-01

    The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices.

  10. Evaluation of sample holders designed for long-lasting X-ray micro-tomographic scans of ex-vivo soft tissue samples

    NASA Astrophysics Data System (ADS)

    Dudak, J.; Zemlicka, J.; Krejci, F.; Karch, J.; Patzelt, M.; Zach, P.; Sykora, V.; Mrzilkova, J.

    2016-03-01

    X-ray microradiography and microtomography are imaging techniques with increasing applicability in the field of biomedical and preclinical research. Application of hybrid pixel detector Timepix enables to obtain very high contrast of low attenuating materials such as soft biological tissue. However X-ray imaging of ex-vivo soft tissue samples is a difficult task due to its structural instability. Ex-vivo biological tissue is prone to fast drying-out which is connected with undesired changes of sample size and shape producing later on artefacts within the tomographic reconstruction. In this work we present the optimization of our Timepix equipped micro-CT system aiming to maintain soft tissue sample in stable condition. Thanks to the suggested approach higher contrast of tomographic reconstructions can be achieved while also large samples that require detector scanning can be easily measured.

  11. Prognostic value of coronary computed tomographic angiography findings in asymptomatic individuals: a 6-year follow-up from the prospective multicentre international CONFIRM study.

    PubMed

    Cho, Iksung; Al'Aref, Subhi J; Berger, Adam; Ó Hartaigh, Bríain; Gransar, Heidi; Valenti, Valentina; Lin, Fay Y; Achenbach, Stephan; Berman, Daniel S; Budoff, Matthew J; Callister, Tracy Q; Al-Mallah, Mouaz H; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Villines, Todd C; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J; Kaufmann, Philipp A; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Chang, Hyuk-Jae; Min, James K

    2018-03-14

    The long-term prognostic benefit of coronary computed tomographic angiography (CCTA) findings of coronary artery disease (CAD) in asymptomatic populations is unknown. From the prospective multicentre international CONFIRM long-term study, we evaluated asymptomatic subjects without known CAD who underwent both coronary artery calcium scoring (CACS) and CCTA (n = 1226). Coronary computed tomographic angiography findings included the severity of coronary artery stenosis, plaque composition, and coronary segment location. Using the C-statistic and likelihood ratio tests, we evaluated the incremental prognostic utility of CCTA findings over a base model that included a panel of traditional risk factors (RFs) as well as CACS to predict long-term all-cause mortality. During a mean follow-up of 5.9 ± 1.2 years, 78 deaths occurred. Compared with the traditional RF alone (C-statistic 0.64), CCTA findings including coronary stenosis severity, plaque composition, and coronary segment location demonstrated improved incremental prognostic utility beyond traditional RF alone (C-statistics range 0.71-0.73, all P < 0.05; incremental χ2 range 20.7-25.5, all P < 0.001). However, no added prognostic benefit was offered by CCTA findings when added to a base model containing both traditional RF and CACS (C-statistics P > 0.05, for all). Coronary computed tomographic angiography improved prognostication of 6-year all-cause mortality beyond a set of conventional RF alone, although, no further incremental value was offered by CCTA when CCTA findings were added to a model incorporating RF and CACS.

  12. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems

    PubMed Central

    Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Naik, Saraswathi V

    2016-01-01

    ABSTRACT Background: Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. Study design: This is an experimental, in vitro study comparing the two groups. Materials and methods: A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. Results: A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Conclusion: Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49. PMID:27274155

  13. Installation of Computerized Procedure System and Advanced Alarm System in the Human Systems Simulation Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Blanc, Katya Lee; Spielman, Zachary Alexander; Rice, Brandon Charles

    2016-04-01

    This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.

  14. Demonstration and Evaluation of the Effects of Incentives on Resource Sharing Using a Computerized Interlibrary Communications System.

    ERIC Educational Resources Information Center

    New England Board of Higher Education, Wellesley, MA. New England Library Information Network.

    The potential for using a computerized communication system to facilitate resource sharing in New England has been investigated by the staff of the New England Information Network (NELINET). The central purpose of their research was to determine whether a strategy for load leveling of interlibrary loan (ILL) requests could be implemented online as…

  15. Computerized Classification Testing under the One-Parameter Logistic Response Model with Ability-Based Guessing

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Huang, Sheng-Yun

    2011-01-01

    The one-parameter logistic model with ability-based guessing (1PL-AG) has been recently developed to account for effect of ability on guessing behavior in multiple-choice items. In this study, the authors developed algorithms for computerized classification testing under the 1PL-AG and conducted a series of simulations to evaluate their…

  16. SYN-OP-SYS™: A Computerized Management Information System for Quality Assurance and Risk Management

    PubMed Central

    Thomas, David J.; Weiner, Jayne; Lippincott, Ronald C.

    1985-01-01

    SYN·OP·SYS™ is a computerized management information system for quality assurance and risk management. Computer software for the efficient collection and analysis of “occurrences” and the clinical data associated with these kinds of patient events is described. The system is evaluated according to certain computer design criteria, and the system's implementation is assessed.

  17. Multidimensional Computerized Adaptive Scholastic Aptitude Test Program Used for Grade 9 Students under Different Reviewing Test Conditions

    ERIC Educational Resources Information Center

    Khunkrai, Naruemon; Sawangboon, Tatsirin; Ketchatturat, Jatuphum

    2015-01-01

    The aim of this research is to study the accurate prediction of comparing test information and evaluation result by multidimensional computerized adaptive scholastic aptitude test program used for grade 9 students under different reviewing test conditions. Grade 9 students of the Secondary Educational Service Area Office in the North-east of…

  18. Early-term and mid-term histologic events during single-level posterolateral intertransverse process fusion with rhBMP-2/collagen carrier and a ceramic bulking agent in a nonhuman primate model: implications for bone graft preparation.

    PubMed

    Khan, Safdar N; Toth, Jeffrey M; Gupta, Kavita; Glassman, Steven D; Gupta, Munish C

    2014-06-01

    We used a nonhuman primate lumbar intertransverse process arthrodesis model to evaluate biological cascade of bone formation using different carrier preparation methods with a single dose of recombinant human bone morphogenetic protein-2 (rhBMP-2) at early time points. To examine early-term/mid-term descriptive histologic and computerized tomographic events in single-level uninstrumented posterolateral nonhuman primate spinal fusions using rhBMP-2/absorbable collagen sponge (ACS) combined with ceramic bulking agents in 3 different configurations. rhBMP-2 on an ACS carrier alone leads to consistent posterolateral lumbar spine fusions in lower-order animals; however, these results have been difficult to replicate in nonhuman primates. Twelve skeletally mature, rhesus macaque monkeys underwent single-level posterolateral arthrodesis at L4-L5. A hydroxyapatite/β-tricalcium phosphate ceramic bulking agent in 3 formulations was used in the treatment groups (n=3). When used, rhBMP-2/ACS at 1.5 mg/cm (3.0 mg rhBMP-2) was combined with 2.5 cm of ceramic bulking agent per side. Animals were euthanized at 4 and 12 weeks postoperative. Computerized tomography scans were performed immediately postoperatively and every 4 weeks until they were euthanized. Sagittal histologic sections were evaluated for bone histogenesis and location, cellular infiltration of the graft/substitute, and bone remodeling activity. Significant histologic differences in the developing fusion appeared between the 3 rhBMP-2/ACS treatment groups at 4 and 12 weeks. At 4 weeks, bone formation appeared to originate at the transverse process and the intertransverse membrane. Cellular infiltration was greatest in granular ceramic groups compared with matrix ceramic group. Minimal to no residual ACS was identified at the early time point. At 12 weeks, marked ceramic remodeling was observed with continued bone formation noted in all carrier groups. At the early time period, histology showed that bone formation appeared to originate at the transverse processes and the intertransverse membrane, indicating that the dorsal muscle bed may not be the only location for bone formation. Histology also showed that the collagen carrier for rhBMP-2 is mostly resorbed by 4 weeks. Our results and previous literature indicate that ceramic bulking agents are needed to provide resistance to compression caused by paraspinal muscles on the fusion bed in the posterolateral environment. Histology showed that ceramic bulking agents may offer long-term scaffolding and a structure to supporting bone formation of the developing fusion mass.

  19. Entropy-Bayesian Inversion of Time-Lapse Tomographic GPR data for Monitoring Dielectric Permittivity and Soil Moisture Variations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Z; Terry, N; Hubbard, S S

    2013-02-12

    In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability distribution functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSim) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less

  20. Entropy-Bayesian Inversion of Time-Lapse Tomographic GPR data for Monitoring Dielectric Permittivity and Soil Moisture Variations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Zhangshuan; Terry, Neil C.; Hubbard, Susan S.

    2013-02-22

    In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability density functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSIM) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less

  1. Performances on the CogState and standard neuropsychological batteries among HIV patients without dementia.

    PubMed

    Overton, Edgar Turner; Kauwe, John S K; Paul, Robert; Tashima, Karen; Tate, David F; Patel, Pragna; Carpenter, Charles C J; Patty, David; Brooks, John T; Clifford, David B

    2011-11-01

    HIV-associated neurocognitive disorders remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (P < 0.01). These data confirm previous correlation data with the computerized battery. Using the five significant parameters from the regression model in a Receiver Operating Characteristic curve, 90% of persons were accurately classified as being cognitively impaired or not. The test battery requires additional evaluation, specifically for identifying persons with mild impairment, a state upon which interventions may be effective.

  2. Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients

    PubMed Central

    Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.

    2008-01-01

    Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982

  3. Computer-aided design evaluation of harvestable mandibular bone volume: a clinical and tomographic human study.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Raffaelli, Luca; D'Addona, Antonio

    2014-06-01

    To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer-aided design (CAD) software program. Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD(®), Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals. CAD calculations yielded a safe harvestable osseous volume of 1.44 cm(3) ± 0.49 for the symphysis and 0.82 cm(3) ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47-0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm(3) ± 0.50 vs. 2.65 cm(3) ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm(3) ± 0.50 (range: 1.80-3.10 cm(3)) and 2.65 cm(3) ± 0.45 (range: 1.90-3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45-1.03). The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm(3) from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation. © 2012 Wiley Periodicals, Inc.

  4. The poppy seed test for colovesical fistula: big bang, little bucks!

    PubMed

    Kwon, Eric O; Armenakas, Noel A; Scharf, Stephen C; Panagopoulos, Georgia; Fracchia, John A

    2008-04-01

    Diagnosis of a colovesical fistula is often challenging, and usually involves numerous invasive and expensive tests and procedures. The poppy seed test stands out as an exception to this rule. We evaluated the accuracy and cost-effectiveness of various established diagnostic tests used to evaluate a suspected colovesical fistula. We identified 20 prospectively entered patients with surgically confirmed colovesical fistulas between 2000 and 2006. Each patient was evaluated preoperatively with a (51)chromium nuclear study, computerized tomography of the abdomen and pelvis with oral and intravenous contrast medium, and the poppy seed test. Costs were calculated using institutional charges, 2006 Medicare limiting approved charges and the market price, respectively. The z test was used to compare the proportion of patients who tested positive for a fistula with each of these modalities. The chromium study was positive in 16 of 20 patients (80%) at a cost of $490.83 per study. Computerized tomography was positive in 14 of 20 patients (70%) at a cost of $652.92 per study. The poppy seed test was positive in 20 of 20 patients (100%) at a cost of $5.37 per study. The difference in the proportion of patients who tested positive for a fistula on computerized tomography and the poppy seed test was statistically significant (p = 0.03). There was no difference between the chromium group and the computerized tomography or poppy seed group (p = 0.72 and 0.12, respectively). The poppy seed test is an accurate, convenient and inexpensive diagnostic test. It is an ideal initial consideration for evaluating a suspected colovesical fistula.

  5. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Peritoneal mesothelioma presenting as an acute surgical abdomen due to jejunal perforation.

    PubMed

    Salemis, Nikolaos S; Tsiambas, Evangelos; Gourgiotis, Stavros; Mela, Ageliki; Karameris, Andreas; Tsohataridis, Efstathios

    2007-11-01

    Peritoneal mesothelioma is a rare disease associated with poor prognosis. Acute abdomen as the first presentation is an extremely rare occurrence. We report an exceptional case of a patient who was found to have a jejunal perforation due to infiltration of peritoneal mesothelioma. A 62-year-old man was admitted with clinical signs of peritonitis. Computerized tomographic scans showed a mass distal to the ligament of Treitz, thickening of the mesentery and a small amount of ascites. Emergency laparotomy revealed a perforated tumor 15 cm distal to the ligament of Treitz and diffuse peritoneal disease. Segmental small bowel resection and suboptimal cytoreduction were performed. Histopathology and immunohistochemistry showed infiltration of malignant mesothelioma. During the postoperative period pleural mesothelioma was also diagnosed. Despite adjuvant chemotherapy, the patient died of disseminated progressive disease 7 months after surgery. Peritoneal mesothelioma is a rare malignancy with grim prognosis. Small bowel involvement is a poor prognostic indicator. Our case of a small bowel perforation due to direct infiltration by peritoneal mesothelioma appears to be the first reported in the English literature.

  7. Current Trends in the Management of Abdominal Aortic Aneurysms

    PubMed Central

    Harris, K.A.; Ameli, F. Michael; Louis, E.L. St.

    1987-01-01

    The treatment of abdominal aortic aneurysm has undergone dramatic changes over the last three decades. More sophisticated diagnostic techniques have allowed early elective repair to be carried out. Improvement has resulted in both morbidity and mortality rates. Investigations such as ultrasound, computerized tomographic scanning and arteriography allow easy confirmation of the diagnosis of aortic aneurysms and permit a better assessment of the extent prior to surgical intervention. Improvement in the pre-operative management, particularly in relation to cardiac, renal, and pulmonary disease, has led to greatly improved results. The most important change in surgical technique has been repair of the aneurysm rather than resection. Combined with better post-operative intensive care units, this development has contributed to the improved morbidity and mortality rates. Although the complication rate of elective repair is low, the major cause of death remains myocardial infarction. As a result of all these improvements, indication for repair of abdominal aortic aneurysms has been extended to patients over the age of 80. Following surgical repair, most patients can be expected to return to normal lifestyles and lifespans. ImagesFigure 2Figure 3Figure 4 PMID:21263973

  8. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coupe, Nicholas J., E-mail: optimus2050@hotmail.com; Ling, Lynn; Cowling, Mark G.

    2009-07-15

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was alsomore » not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.« less

  9. Virginia Transit Performance Evaluation Package (VATPEP).

    DOT National Transportation Integrated Search

    1987-01-01

    The Virginia Transit Performance Evaluation Package (VATPEP), a computer software package, is documented. This is the computerized version of the methodology used by the Virginia Department of Transportation to evaluate the performance of public tran...

  10. [Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study].

    PubMed

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, p<0.001); satisfaction decreased with age (p<0.001). Physicians scored lower concerning the potential of the computerized physician order entry for improving patient safety (5.45±2.20 versus 8.09±2.21, p<0.001) and the ease of using the computerized physician order entry (3.83±1.88 versus 6.44±2.31, p<0.001). The characteristics independently associated with satisfaction were the system's user-friendliness, accuracy, capacity to provide clear information, and fast response time. Six months after its implementation, healthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.

  11. Acceleration of image-based resolution modelling reconstruction using an expectation maximization nested algorithm.

    PubMed

    Angelis, G I; Reader, A J; Markiewicz, P J; Kotasidis, F A; Lionheart, W R; Matthews, J C

    2013-08-07

    Recent studies have demonstrated the benefits of a resolution model within iterative reconstruction algorithms in an attempt to account for effects that degrade the spatial resolution of the reconstructed images. However, these algorithms suffer from slower convergence rates, compared to algorithms where no resolution model is used, due to the additional need to solve an image deconvolution problem. In this paper, a recently proposed algorithm, which decouples the tomographic and image deconvolution problems within an image-based expectation maximization (EM) framework, was evaluated. This separation is convenient, because more computational effort can be placed on the image deconvolution problem and therefore accelerate convergence. Since the computational cost of solving the image deconvolution problem is relatively small, multiple image-based EM iterations do not significantly increase the overall reconstruction time. The proposed algorithm was evaluated using 2D simulations, as well as measured 3D data acquired on the high-resolution research tomograph. Results showed that bias reduction can be accelerated by interleaving multiple iterations of the image-based EM algorithm solving the resolution model problem, with a single EM iteration solving the tomographic problem. Significant improvements were observed particularly for voxels that were located on the boundaries between regions of high contrast within the object being imaged and for small regions of interest, where resolution recovery is usually more challenging. Minor differences were observed using the proposed nested algorithm, compared to the single iteration normally performed, when an optimal number of iterations are performed for each algorithm. However, using the proposed nested approach convergence is significantly accelerated enabling reconstruction using far fewer tomographic iterations (up to 70% fewer iterations for small regions). Nevertheless, the optimal number of nested image-based EM iterations is hard to be defined and it should be selected according to the given application.

  12. Evaluation of hepatic arterial anatomy by multidetector computed tomographic angiography in living donor liver transplantation.

    PubMed

    Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit

    2016-06-01

    The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.

  13. IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices

    PubMed Central

    Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad

    2016-01-01

    Purpose The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. Materials and Methods A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. Results The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). Conclusion IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices. PMID:27672615

  14. An Evaluation of Computerized Tests as Predictors of Job Performance: II. Differential Validity for Global and Job Element Criteria. Final Report.

    ERIC Educational Resources Information Center

    Cory, Charles H.

    This report presents data concerning the validity of a set of experimental computerized and paper-and-pencil tests for measures of on-job performance on global and job elements. It reports on the usefulness of 30 experimental and operational variables for predicting marks on 42 job elements and on a global criterion for Electrician's Mate,…

  15. Evaluation of Psychology Clinicians' Attitudes towards Computerized Cognitive Behavior Therapy, for Use in Their Future Clinical Practice, with Regard to Treating Those Suffering from Anxiety and Depression

    ERIC Educational Resources Information Center

    Dunne, Nivek

    2017-01-01

    Computerized Cognitive Behavioural Therapy (CCBT) is an empirically supported therapeutic modality used in the treatment of anxiety and depression. It is an important area of research considering there is much research lacking in this area, especially regarding trainee and qualified psychology clinicians' attitudes which are informative in terms…

  16. Trace: a high-throughput tomographic reconstruction engine for large-scale datasets

    DOE PAGES

    Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De; ...

    2017-01-28

    Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less

  17. Use of radiography, computed tomography and magnetic resonance imaging for evaluation of navicular syndrome in the horse.

    PubMed

    Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S

    2000-01-01

    Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.

  18. Trace: a high-throughput tomographic reconstruction engine for large-scale datasets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De

    Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less

  19. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, W; Wang, J; Zhang, H

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss ormore » gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that computerized PET/CT image analysis holds great potential to improve the accuracy in evaluation of tumor response. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less

  20. Use of the bolus tracking technique for the tomographic evaluation of the uretero-vesicular junction in dogs and assessment of dose records.

    PubMed

    Longo, Maurizio; Andreis, Maria Elena; Pettinato, Cinzia; Ravasio, Giuliano; Rabbogliatti, Vanessa; De Zani, Donatella; Di Giancamillo, Mauro; Zani, Davide Danilo

    2016-03-29

    The aim of the work is the application of a bolus tracking technique for tomographic evaluation of the uretero-vesicular junction in dogs. Ten adult dogs (8-14 years) with variable body weight (2,8-32 kg) were enrolled in the prospective study. The patients were placed in sternal recumbency with a 10° elevated pelvis and the visualization of the uretero-vesicular junction was obtained with the bolus tracking technique after intravenous administration of non-ionic contrast medium. In the post-contrast late phase a region of interest was placed within the lumen of the distal ureters and the density values were monitored before starting the helical scan. The uretero-vesicular junction was clearly visible in 100% of patients with the visualization of the endoluminal ureteral contrast enhancement and bladder washout. At the end of the tomographic study an evaluation of the dose records was performed and compared to human exposures reported in literature for the pelvic region. The effective dose estimated for each patient (37,5-138 mSv) proved to be elevated, when compared to those reported in human patients. The bolus tracking technique could be applied for the visualization of the uretero-vesicular junction in non-pathological patients, placing the region of interest in the distal ureters. The high effective doses recorded in our study support the need of specific thresholds for veterinary patients, pointing out the attention for paediatric patient's exposure also in veterinary imaging.

  1. Majewski osteodysplastic primordial dwarfism type II (MOPD II): expanding the vascular phenotype.

    PubMed

    Bober, Michael B; Khan, Nadia; Kaplan, Jennifer; Lewis, Kristi; Feinstein, Jeffrey A; Scott, Charles I; Steinberg, Gary K

    2010-04-01

    Majewski Osteodysplastic Primordial Dwarfism, Type II (MOPD II) is a rare, autosomal recessive disorder. Features include severe intrauterine growth retardation (IUGR), poor postnatal growth (adult stature approximately 100 cm), severe microcephaly, skeletal dysplasia, characteristic facial features, and normal or near normal intelligence. An Institutional Review Board (IRB) approved registry was created and currently follows 25 patients with a diagnosis of MOPD II. Based on previous studies, a neurovascular screening program was implemented and 13 (52%) of these patients have been found to have cerebral neurovascular abnormalities including moyamoya angiopathy and/or intracranial aneurysms. The typical moyamoya pathogenesis begins with vessel narrowing in the supraclinoid internal carotid artery, anterior cerebral (A1) or middle cerebral (M1) artery segments. The narrowing may predominate initially on one side, progresses to bilateral stenosis, with subsequent occlusion of the vessels and collateral formation. We present four patients who, on neurovascular screening, were found to have cerebrovascular changes. Two were asymptomatic, one presented with a severe headache and projectile vomiting related to a ruptured aneurysm, and one presented after an apparent decline in cognitive functioning. Analysis of the registry suggests screening for moyamoya disease be performed at the time of MOPD II diagnosis and at least every 12-18 months using MRA or computerized tomographic angiography (CTA). We believe this is imperative. If diagnosed early enough, re-vascularization and aneurysm treatment in skilled hands can be performed safely and prevent or minimize long-term sequelae in this population. Emergent evaluation is also needed when other neurologic or cardiac symptoms are present. (c) 2010 Wiley-Liss, Inc.

  2. Evaluation of Spontaneous Spinal Cerebrospinal Fluid Leaks Disease by Computerized Image Processing.

    PubMed

    Yıldırım, Mustafa S; Kara, Sadık; Albayram, Mehmet S; Okkesim, Şükrü

    2016-05-17

    Spontaneous Spinal Cerebrospinal Fluid Leaks (SSCFL) is a disease based on tears on the dura mater. Due to widespread symptoms and low frequency of the disease, diagnosis is problematic. Diagnostic lumbar puncture is commonly used for diagnosing SSCFL, though it is invasive and may cause pain, inflammation or new leakages. T2-weighted MR imaging is also used for diagnosis; however, the literature on T2-weighted MRI states that findings for diagnosis of SSCFL could be erroneous when differentiating the diseased and control. One another technique for diagnosis is CT-myelography, but this has been suggested to be less successful than T2-weighted MRI and it needs an initial lumbar puncture. This study aimed to develop an objective, computerized numerical analysis method using noninvasive routine Magnetic Resonance Images that can be used in the evaluation and diagnosis of SSCFL disease. Brain boundaries were automatically detected using methods of mathematical morphology, and a distance transform was employed. According to normalized distances, average densities of certain sites were proportioned and a numerical criterion related to cerebrospinal fluid distribution was calculated. The developed method was able to differentiate between 14 patients and 14 control subjects significantly with p = 0.0088 and d = 0.958. Also, the pre and post-treatment MRI of four patients was obtained and analyzed. The results were differentiated statistically (p = 0.0320, d = 0.853). An original, noninvasive and objective diagnostic test based on computerized image processing has been developed for evaluation of SSCFL. To our knowledge, this is the first computerized image processing method for evaluation of the disease. Discrimination between patients and controls shows the validity of the method. Also, post-treatment changes observed in four patients support this verdict.

  3. [Computerized acquisition and elaboration of clinical data in Rheumatology during ten years: state of art and prospectives

    PubMed

    Troise Rioda, W.; Nervetti, A.

    2001-01-01

    The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.

  4. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    PubMed

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  5. Features of computerized clinical decision support systems supportive of nursing practice: a literature review.

    PubMed

    Lee, Seonah

    2013-10-01

    This study aimed to organize the system features of decision support technologies targeted at nursing practice into assessment, problem identification, care plans, implementation, and outcome evaluation. It also aimed to identify the range of the five stage-related sequential decision supports that computerized clinical decision support systems provided. MEDLINE, CINAHL, and EMBASE were searched. A total of 27 studies were reviewed. The system features collected represented the characteristics of each category from patient assessment to outcome evaluation. Several features were common across the reviewed systems. For the sequential decision support, all of the reviewed systems provided decision support in sequence for patient assessment and care plans. Fewer than half of the systems included problem identification. There were only three systems operating in an implementation stage and four systems in outcome evaluation. Consequently, the key steps for sequential decision support functions were initial patient assessment, problem identification, care plan, and outcome evaluation. Providing decision support in such a full scope will effectively help nurses' clinical decision making. By organizing the system features, a comprehensive picture of nursing practice-oriented computerized decision support systems was obtained; however, the development of a guideline for better systems should go beyond the scope of a literature review.

  6. The effects of mild and severe traumatic brain injury on speed of information processing as measured by the computerized tests of information processing (CTIP).

    PubMed

    Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra

    2007-01-01

    In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.

  7. Learning effect of computerized cognitive tests in older adults

    PubMed Central

    de Oliveira, Rafaela Sanches; Trezza, Beatriz Maria; Busse, Alexandre Leopold; Jacob-Filho, Wilson

    2014-01-01

    ABSTRACT Objective: To evaluate the learning effect of computerized cognitive testing in the elderly. Methods: Cross-sectional study with 20 elderly, 10 women and 10 men, with average age of 77.5 (±4.28) years. The volunteers performed two series of computerized cognitive tests in sequence and their results were compared. The applied tests were: Trail Making A and B, Spatial Recognition, Go/No Go, Memory Span, Pattern Recognition Memory and Reverse Span. Results: Based on the comparison of the results, learning effects were observed only in the Trail Making A test (p=0.019). Other tests performed presented no significant performance improvements. There was no correlation between learning effect and age (p=0.337) and education (p=0.362), as well as differences between genders (p=0.465). Conclusion: The computerized cognitive tests repeated immediately afterwards, for elderly, revealed no change in their performance, with the exception of the Trail Making test, demonstrating high clinical applicability, even in short intervals. PMID:25003917

  8. Computerized N-acetylcysteine physician order entry by template protocol for acetaminophen toxicity.

    PubMed

    Thompson, Trevonne M; Lu, Jenny J; Blackwood, Louisa; Leikin, Jerrold B

    2011-01-01

    Some medication dosing protocols are logistically complex for traditional physician ordering. The use of computerized physician order entry (CPOE) with templates, or order sets, may be useful to reduce medication administration errors. This study evaluated the rate of medication administration errors using CPOE order sets for N-acetylcysteine (NAC) use in treating acetaminophen poisoning. An 18-month retrospective review of computerized inpatient pharmacy records for NAC use was performed. All patients who received NAC for the treatment of acetaminophen poisoning were included. Each record was analyzed to determine the form of NAC given and whether an administration error occurred. In the 82 cases of acetaminophen poisoning in which NAC was given, no medication administration errors were identified. Oral NAC was given in 31 (38%) cases; intravenous NAC was given in 51 (62%) cases. In this retrospective analysis of N-acetylcysteine administration using computerized physician order entry and order sets, no medication administration errors occurred. CPOE is an effective tool in safely executing complicated protocols in an inpatient setting.

  9. Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus.

    PubMed

    Luz, Allan; Lopes, Bernardo; Hallahan, Katie M; Valbon, Bruno; Ramos, Isaac; Faria-Correia, Fernando; Schor, Paulo; Dupps, William J; Ambrósio, Renato

    2016-07-01

    To evaluate the performance of the Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Depew, NY) variables and Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) tomographic parameters in differentiating forme fruste keratoconus (FFKC) from normal corneas, and to assess a combined biomechanical and tomographic parameter to improve outcomes. Seventy-six eyes of 76 normal patients and 21 eyes of 21 patients with FFKC were included in the study. Fifteen variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior and 37 ORA waveform parameters were tested. Sixteen tomographic parameters from Pentacam HR were tested. Logistic regression was used to produce a combined biomechanical and tomography linear model. Differences between groups were assessed by the Mann-Whitney U test. The area under the receiver operating characteristics curve (AUROC) was used to compare diagnostic performance. No statistically significant differences were found in age, thinnest point, central corneal thickness, and maximum keratometry between groups. Twenty-one parameters showed significant differences between the FFKC and control groups. Among the ORA waveform measurements, the best parameters were those related to the area under the first peak, p1area1 (AUROC, 0.717 ± 0.065). Among the investigator ORA variables, a measure incorporating the pressure-deformation relationship of the entire response cycle was the best predictor (hysteresis loop area, AUROC, 0.688 ± 0.068). Among tomographic parameters, Belin/Ambrósio display showed the highest predictive value (AUROC, 0.91 ± 0.057). A combination of parameters showed the best result (AUROC, 0.953 ± 0.024) outperforming individual parameters. Tomographic and biomechanical parameters demonstrated the ability to differentiate FFKC from normal eyes. A combination of both types of information further improved predictive value. [J Refract Surg. 2016;32(7):479-485.]. Copyright 2016, SLACK Incorporated.

  10. Computerized quantitative evaluation of mammographic accreditation phantom images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Yongbum; Tsai, Du-Yih; Shinohara, Norimitsu

    2010-12-15

    Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria,more » the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.« less

  11. Application of gray level mapping in computed tomographic colonography: a pilot study to compare with traditional surface rendering method for identification and differentiation of endoluminal lesions

    PubMed Central

    Chen, Lih-Shyang; Hsu, Ta-Wen; Chang, Shu-Han; Lin, Chih-Wen; Chen, Yu-Ruei; Hsieh, Chin-Chiang; Han, Shu-Chen; Chang, Ku-Yaw; Hou, Chun-Ju

    2017-01-01

    Objective: In traditional surface rendering (SR) computed tomographic endoscopy, only the shape of endoluminal lesion is depicted without gray-level information unless the volume rendering technique is used. However, volume rendering technique is relatively slow and complex in terms of computation time and parameter setting. We use computed tomographic colonography (CTC) images as examples and report a new visualization technique by three-dimensional gray level mapping (GM) to better identify and differentiate endoluminal lesions. Methods: There are 33 various endoluminal cases from 30 patients evaluated in this clinical study. These cases were segmented using gray-level threshold. The marching cube algorithm was used to detect isosurfaces in volumetric data sets. GM is applied using the surface gray level of CTC. Radiologists conducted the clinical evaluation of the SR and GM images. The Wilcoxon signed-rank test was used for data analysis. Results: Clinical evaluation confirms GM is significantly superior to SR in terms of gray-level pattern and spatial shape presentation of endoluminal cases (p < 0.01) and improves the confidence of identification and clinical classification of endoluminal lesions significantly (p < 0.01). The specificity and diagnostic accuracy of GM is significantly better than those of SR in diagnostic performance evaluation (p < 0.01). Conclusion: GM can reduce confusion in three-dimensional CTC and well correlate CTC with sectional images by the location as well as gray-level value. Hence, GM increases identification and differentiation of endoluminal lesions, and facilitates diagnostic process. Advances in knowledge: GM significantly improves the traditional SR method by providing reliable gray-level information for the surface points and is helpful in identification and differentiation of endoluminal lesions according to their shape and density. PMID:27925483

  12. Optical tomographic detection of rheumatoid arthritis with computer-aided classification schemes

    NASA Astrophysics Data System (ADS)

    Klose, Christian D.; Klose, Alexander D.; Netz, Uwe; Beuthan, Jürgen; Hielscher, Andreas H.

    2009-02-01

    A recent research study has shown that combining multiple parameters, drawn from optical tomographic images, leads to better classification results to identifying human finger joints that are affected or not affected by rheumatic arthritis RA. Building up on the research findings of the previous study, this article presents an advanced computer-aided classification approach for interpreting optical image data to detect RA in finger joints. Additional data are used including, for example, maximum and minimum values of the absorption coefficient as well as their ratios and image variances. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index and area under the curve AUC. Results were compared to different benchmarks ("gold standard"): magnet resonance, ultrasound and clinical evaluation. Maximum accuracies (AUC=0.88) were reached when combining minimum/maximum-ratios and image variances and using ultrasound as gold standard.

  13. Computerized Adaptive Testing Project: Objectives and Requirements.

    DTIC Science & Technology

    1982-07-01

    developing a cqmputerlzed adaptive lwfb system ( CAT ). SiN 0102- LP. Old. "O AM"- S/M "of F.g~ smuuim ftmAYUSN 0 IM ~ A joint-service coordinated effort is In...progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the Military Enlistment Processing Stations...lead laboratory for this effort. This report is intended to serve as a working paper documenting CAT system functional requirements and schedules. It

  14. Can macrocirculation changes predict nonhealing diabetic foot ulcers?

    PubMed

    Lee, Ye-Na; Kim, Hyon-Surk; Kang, Jeong-A; Han, Seung-Kyu

    2014-01-01

    Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.

  15. A new art code for tomographic interferometry

    NASA Technical Reports Server (NTRS)

    Tan, H.; Modarress, D.

    1987-01-01

    A new algebraic reconstruction technique (ART) code based on the iterative refinement method of least squares solution for tomographic reconstruction is presented. Accuracy and the convergence of the technique is evaluated through the application of numerically generated interferometric data. It was found that, in general, the accuracy of the results was superior to other reported techniques. The iterative method unconditionally converged to a solution for which the residual was minimum. The effects of increased data were studied. The inversion error was found to be a function of the input data error only. The convergence rate, on the other hand, was affected by all three parameters. Finally, the technique was applied to experimental data, and the results are reported.

  16. Comparative evaluation of the cadaveric and computed tomographic features of the coelomic cavity in the green iguana (Iguana iguana), black and white tegu (Tupinambis merianae) and bearded dragon (Pogona vitticeps).

    PubMed

    Banzato, T; Selleri, P; Veladiano, I A; Zotti, A

    2013-12-01

    Contrast-enhanced computed tomographic studies of the coelomic cavity in four green iguanas, four black and white tegus and four bearded dragons were performed using a conventional CT scanner. Anatomical reference cross sections were obtained from four green iguana, four black and white tegu and six bearded dragon cadavers; the specimens were stored in a -20°C freezer for 24 h then sliced into 5-mm intervals. The frozen sections were cleaned with water and photographed on both sides. The individual anatomical structures were identified by means of the available literature; these were labelled first on the anatomical images and then matched to the corresponding computed tomography images. The results provide an atlas of the normal cross-sectional and computed tomographic anatomy of the coelomic cavity in the green iguana, the black and white tegu and the bearded dragon, which is useful in the interpretation of any imaging modality. © 2013 Blackwell Verlag GmbH.

  17. Towards Omni-Tomography—Grand Fusion of Multiple Modalities for Simultaneous Interior Tomography

    PubMed Central

    Wang, Ge; Zhang, Jie; Gao, Hao; Weir, Victor; Yu, Hengyong; Cong, Wenxiang; Xu, Xiaochen; Shen, Haiou; Bennett, James; Furth, Mark; Wang, Yue; Vannier, Michael

    2012-01-01

    We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose “omni-tomography”, a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality fusion: Software based image registration and hybrid scanners such as PET-CT, PET-MRI, and SPECT-CT among others. While there are intrinsic limitations with both approaches, the main obstacle to the seamless fusion of multiple imaging modalities has been the bulkiness of each individual imager and the conflict of their physical (especially spatial) requirements. To address this challenge, omni-tomography is now unveiled as an emerging direction for biomedical imaging and systems biomedicine. PMID:22768108

  18. COMPLY

    EPA Pesticide Factsheets

    A computerized screening tool for evaluating radiation exposure from atmospheric releases of radionuclides. May be used for demonstrating compliance with some EPA and Nuclear Regulatory Commission regulations

  19. A computerized stroop test for the evaluation of psychotropic drugs in healthy participants.

    PubMed

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usha Rani; Shobha, J C; Reddy, A Praveen

    2013-04-01

    The Stroop paradigm evaluates susceptibility to interference and is sensitive to dysfunction in frontal lobes and drug effects. The aim of the present study was to establish a simple and reliable computerized version of Stroop color-word test, which can be used for screening of various psychotropic drugs. The standardized method was followed in all cases, by recording the reaction time (RT) in msec in 24 healthy participants using computerized version of Stroop color-word test. Reproducibility of the test procedure was evaluated by recording the RTs by a single experimenter on two sessions (interday reproducibility). Validity of the model was further tested by evaluating the psychotropic effect of Zolpidem 5 mg, Caffeine 500 mg, or Placebo on 24 healthy subjects in a randomized, double blind three-way crossover design. The method was found to produce low variability with coefficient of variation less than 10%. Interday reproducibility was very good as shown by Bland-Altman plot with most of the values within ±2SD. There was a significant increase in RTs in Stroop performance with Zolpidem at 1 hr and 2 hrs; in contrast, caffeine significantly decreased RTs in Stroop performance at 1 hr only compared to placebo. The Stroop color-word recording and analysis system is simple, sensitive to centrally acting drug effects, and has potential for future experimental psychomotor assessment studies.

  20. Computerization of a preanesthetic evaluation and user satisfaction evaluation.

    PubMed

    Arias, Antonio; Benítez, Sonia; Canosa, Daniela; Borbolla, Damián; Staccia, Gustavo; Plazzotta, Fernando; Casais, Marcela; Michelangelo, Hernán; Luna, Daniel; Bernaldo de Quirós, Fernán Gonzalez

    2010-01-01

    Preanesthetic evaluation purpose is to reduce morbidity and mortality through the review of the patient's medical history, clinical examination, and targeted clinical studies, providing referrals for medical consultations when appropriated. Changes in patient care, standards of health information management and patterns of perioperative care, have resulted in a re-conceptualization of this process where the documentation of patient medical information, the efforts in training and maintaining the integrity of the medical-legal evaluation are areas of concern. The aim of this paper is to describe the design, development, training, and implementation of a computerized preanesthetic evaluation form associated to the evaluation of the user satisfaction with the system. Since the system went live in September 2008 there were 15121 closed structured forms, 60% for ambulatory procedures and 40 % for procedures that required hospital admission. 82% of total closed structured forms had recorded a risk of the procedures of 1-2, according to the American Society of Anesthesiologists classification. The survey indicates a positive general satisfaction of the users with the system.

  1. Cost-effectiveness of lung cancer screening and treatment methods: a systematic review of systematic reviews.

    PubMed

    Azar, Farbod Ebadifard; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Mazdaki, Alireza; Rezapour, Aziz; Ebrahimi, Parvin; Yousefzadeh, Negar

    2017-06-19

    Due to extensive literature in the field of lung cancer and their heterogeneous results, the aim of this study was to systematically review of systematic reviews studies which reviewed the cost-effectiveness of various lung cancer screening and treatment methods. In this systematic review of systematic reviews study, required data were collected searching the following key words which selected from Mesh: "lung cancer", "lung oncology", "lung Carcinoma", "lung neoplasm", "lung tumors", "cost- effectiveness", "systematic review" and "Meta-analysis". The following databases were searched: PubMed, Cochrane Library electronic databases, Google Scholar, and Scopus. Two reviewers (RA and A-AS) evaluated the articles according to the checklist of "assessment of multiple systematic reviews" (AMSTAR) tool. Overall, information of 110 papers was discussed in eight systematic reviews. Authors focused on cost-effectiveness of lung cancer treatments in five systematic reviews. Targeted therapy options (bevacizumab, Erlotinib and Crizotinib) show an acceptable cost-effectiveness. Results of three studies failed to show cost-effectiveness of screening methods. None of the studies had used the meta-analysis method. The Quality of Health Economic Studies (QHES) tool and Drummond checklist were mostly used in assessing the quality of articles. Most perspective was related to the Payer (64 times) and the lowest was related to Social (11times). Most cases referred to Incremental analysis (82%) and also the lowest point of referral was related to Discounting (in 49% of the cases). The average quality score of included studies was calculated 9.2% from 11. Targeted therapy can be an option for the treatment of lung cancer. Evaluation of the cost-effectiveness of computerized tomographic colonography (CTC) in lung cancer screening is recommended. The perspective of the community should be more taken into consideration in studies of cost-effectiveness. Paying more attention to the topic of Discounting will be necessary in the studies.

  2. Investigation of the reproducibility and reliability of sagittal vertebral inclination measurements from MR images of the spine.

    PubMed

    Vrtovec, Tomaž; Pernuš, Franjo; Likar, Boštjan

    2014-10-01

    In this study, sagittal vertebral inclination (SVI) was systematically evaluated for 28 vertebrae (segments between T4 and L5) in magnetic resonance (MR) images of one normal and one scoliotic subject to compare the performance of manual and computerized measurements, and identify the most reproducible and reliable measurements. Manual measurements were performed by three observers, who identified on two occasions the distinctive anatomical landmarks required to evaluate SVI by six measurement methods, i.e. the superior tangents, inferior tangents, anterior tangents, posterior tangents, mid-endplate lines and mid-wall lines. Computerized measurements were performed by automatically evaluating SVI from the symmetry of vertebral anatomical structures in two-dimensional (2D) sagittal cross-sections and in three-dimensional (3D) volumetric images. The mid-wall lines and posterior tangents proved to be the manual measurements with the lowest intra-observer (standard deviation, SD, of 1.4° and 1.7°, respectively) and inter-observer variability (SD of 1.9° and 2.4°, respectively). The strongest inter-method agreement was found between the mid-wall lines and posterior tangents (SD of 2.0°). Computerized measurements in 2D and in 3D resulted in intra-observer (SD of 2.8° and 3.1°, respectively) and inter-observer variability (SD of 3.8° and 5.2°, respectively) that were comparable to those of the superior tangents (SD of 2.6° and 3.7°) and inferior tangents (SD of 3.2° and 4.5°), which represent standard Cobb angle measurements. It can be concluded that computerized measurements of SVI should be based on the inclination of vertebral body walls. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Chondro-manubrial deformity and bifid rib, rare variations seen in pectus carinatum: a radiological finding.

    PubMed

    Allwyn Joshua, S; Shetty, Lathika; Pare, V S; Sebastian, Roopa

    2013-07-01

    Pectus carinatum or protrusion deformity of chest wall is less frequently occurring anterior chest wall deformity when compared to pectus excavatum. It may be classified as type 1 or chondro-gladiolar and type 2 or chondro-manubrial deformity. Other variations seen are symmetrical and asymmetrical pectus carinatum. Here we present two unique case reports, one with chondro-manubrial deformity (Currarino-Silverman syndrome) and other with asymmetrical pectus carinatum having bifid rib which are some of the rare variations seen in pectus carinatum found during Computerized tomographic examination. Currarino-Silverman syndrome is a type 2 pectus carinatum, a rare deformity with chondro-manubrial involvement and usually associated congenital heart diseases. Early fusion of sternal plates is one of the known theories in producing this deformity. On the other hand, asymmetrical pectus deformity are usually seen due to imbalance or abnormality in growth plates of costal cartilages leading to forked rib or bifid rib, which are accidently seen on radiological examination. To conclude, our reports would help in differential diagnosis from frequently occurring conditions affecting chest like chondro-gladiolar deformity, pectus excavatum, chest wall tumours, rib fractures and intra thoracic ribs.

  4. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  5. Electrical Impedance Tomography Technology (EITT) Project

    NASA Technical Reports Server (NTRS)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Development of a portable, lightweight device providing two-dimensional tomographic imaging of the human body using impedance mapping. This technology can be developed to evaluate health risks and provide appropriate medical care on the ISS, during space travel and on the ground.

  6. The role of preoperative CT scan in patients with tracheoesophageal fistula: a review.

    PubMed

    Garge, Saurabh; Rao, K L N; Bawa, Monika

    2013-09-01

    The morbidity and mortality associated with esophageal atresia with or without a fistula make it a challenging congenital abnormality for the pediatric surgeon. Anatomic factors like inter-pouch gap and origin of fistula are not taken into consideration in various prognostic classifications. The preoperative evaluation of these cases with computerized tomography (CT) has been used by various investigators to delineate these factors. We reviewed these studies to evaluate the usefulness of this investigation in the intra operative and post operative period. A literature search was done on all peer-reviewed articles published on preoperative computed tomography (CT) in cases of tracheoesophageal fistula using the PUBMED and MEDLINE search engines. Key words included tracheoesophageal fistula, computerized tomography, virtual bronchoscopy, and 3D computerized tomography reconstruction. Further, additional articles were selected from the list of references obtained from the retrieved publications. A total of 8 articles were selected for analysis. In most of the studies, comprising 96 patients, observations noted in preoperative CT were confirmed during surgery. In a study by Mahalik et al [Mahalik SK, Sodhi KS, Narasimhan KL, Rao KL. Role of preoperative 3D CT reconstruction for evaluation of patients with esophageal atresia and tracheoesophageal fistula. Pediatr Surg Int. 2012 Jun 22. [Epub ahead of print

  7. [The importance of neurological examinations in the age of the technological revolution].

    PubMed

    Berbel-García, A; González-Spínola, J; Martínez-Salio, A; Porta-Etessam, J; Pérez-Martínez, D A; de Toledo, M; Sáiz-Díaz, R A

    Neurologic practice and care have been modified in many important ways during the past ten years, to adapt to the explosion of new information and new technology. Students, residents and practicing physicians have been continuing programs to a model that focuses almost exclusively on the applications to neurologic disorders of the new knowledge obtained from biomedical research. On the other hand high demand for outpatient neurologic care prevents adequate patient's evaluation. Case 1: 65 years old female. Occipital headache diagnosed of tensional origin (normal computerized tomography). Two months later is re-evaluated due to intractable pain and hypoglossal lesion. An amplified computerized tomography revealed a occipital condyle metastasis. Case 2: 21 years old female. Clinical suspicion of demyelinating disease due to repeated facial paresis and sensitive disorder. General exploration and computerized tomography revealed temporo-mandibular joint. Case 3: 60 years old female. Valuation of anticoagulant therapy due to repeated transient ischemic attacks. She suffered from peripheral facial palsy related to auditory cholesteatoma. Neurologic education is nowadays orientated to new technologies. On the other hand, excessive demand prevents adequate valuation and a minute exploration is substituted by complementary evaluations. These situations generate diagnostic mistakes or iatrogenic. It would be important a consideration of the neurologic education profiles and fulfillment of consultations time recommendations for outpatients care.

  8. Impact of implementing electronic clinical practice guidelines for the diagnosis, control and treatment of cardiovascular risk factors: A pre-post controlled study.

    PubMed

    Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M

    To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  9. Microcomputers: Software Evaluation. Evaluation Guides. Guide Number 17.

    ERIC Educational Resources Information Center

    Gray, Peter J.

    This guide discusses three critical steps in selecting microcomputer software and hardware: setting the context, software evaluation, and managing microcomputer use. Specific topics addressed include: (1) conducting an informal task analysis to determine how the potential user's time is spent; (2) identifying tasks amenable to computerization and…

  10. Why Data Linkage? The Importance of CODES (Crash Outcome Data Evaluation System)

    DOT National Transportation Integrated Search

    1996-06-01

    This report briefly explains the computerized linked data system, Crash Outcome : Data Evaluation System (CODES) that provides greater depth accident data : analysis. The linking of data helps researchers to understand the nature of : traffic acciden...

  11. Magnetic resonance imaging and computerized tomography in malignant external otitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gherini, S.G.; Brackmann, D.E.; Bradley, W.G.

    1986-05-01

    In malignant external otitis (MEO), determining the anatomic extent of disease and evaluating the physiologic response to therapy remain a problem. Magnetic resonance imaging (MRI) has recently become available in limited clinical settings. Four patients with MEO were evaluated using MRI, computerized tomography (CT), technetium-99 (Tc-99) bone scanning, and gallium-67 citrate (Ga-67 citrate) scanning. MRI is superior to CT, Tc-99 bone scanning, and Ga-67 citrate scanning in evaluating the anatomic extent of soft tissue changes in MEO. MRI alone cannot be relied upon to determine the physiologic response to therapy. MRI can, however, serve as a valuable guide to themore » interpretation of Tc-99 bone and Ga-67 citrate scans, and in this respect, MRI is extremely useful in the treatment of MEO.« less

  12. Evaluation and Information in the Field of Technical Aids for Disabled Persons: An European Perspective. Monograph Number Thirty-Five.

    ERIC Educational Resources Information Center

    Pedotti, Antonio, Ed.; Andrich, Renzo, Ed.

    The monograph provides information on evaluation of technical aids, wheelchairs, and computerized information systems for disabled persons. The first chapter provides a general overview of actions of the European Community concerning technical aids evaluation, information on the "Concerted Action" program called "Evaluation of…

  13. Endocrine abnormalities in critical care patients with moderate-to-severe head trauma: incidence, pattern and predisposing factors.

    PubMed

    Dimopoulou, Ioanna; Tsagarakis, Stylianos; Theodorakopoulou, Maria; Douka, Evangelia; Zervou, Maria; Kouyialis, Andreas T; Thalassinos, Nikolaos; Roussos, Charis

    2004-06-01

    To investigate the incidence and type of endocrine abnormalities in critical care patients with traumatic brain injury (TBI) and to examine their relationships to possible predisposing factors. Prospective study. General intensive care unit in a university hospital. Thirty-four TBI patients (27 men, 7 women), having a mean age of 37+/-16 years, were studied after weaning from mechanical ventilation. Baseline endocrine assessment was carried out by measuring cortisol, corticotropin, dehydroepiandrosterone sulfate, free thyroxine, thyrotropin (TSH), testosterone, oestradiol, follicle stimulating hormone (FSH), luteinizing hormone, prolactin, growth hormone and insulin-like growth factor I. Dynamic evaluation was performed by human corticotropin releasing hormone and growth hormone releasing hormone in all patients. Male patients underwent additional investigation with gonadotropin-releasing hormone. Severity of neurological derangement was graded according to Glasgow Coma Scale (GCS), Marshall Computerized Tomographic Classification and intracranial pressure (ICP) levels. Eighteen of the 34 patients (53%) had an abnormal result in at least one hormonal axis tested, with cortisol hyporesponsiveness and gonadal dysfunction being equally common, affecting 24% of patients. Endocrine abnormalities were associated with a higher brain CT-scan classification score ( p=0.02). The GCS on admission correlated positively with baseline FSH (r=0.37, p=0.03), peak FSH (r=0.41, p=0.03), testosterone (r=0.44, p=0.02) and TSH (r=0.39, p=0.03). There were no relations between ICP(max) and any baseline or dynamic hormone measurements. Patients with TBI receiving critical care show changes in their neuroendocrine responses, which depend upon clinical and radiological measures of head injury severity. Most common abnormalities include cortisol hyporesponsiveness and hypogonadism.

  14. Cost-effectiveness of Colorectal Cancer Screening and Treatment Methods: Mapping of Systematic Reviews

    PubMed Central

    Abdolahi, Hossein Mashhadi; Asiabar, Ali Sarabi; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Rezapour, Aziz

    2018-01-01

    Objective: Due to extensive literature on colorectal cancer and their heterogeneous results, this study aimed to summarize the systematic reviews which review the cost-effectiveness studies on different aspects of colorectal cancer. Methods: The required data were collected by searching the following key words according to MeSH: “colorectal cancer,” “colorectal oncology,” “colorectal carcinoma,” “colorectal neoplasm,” “colorectal tumors,” “cost-effectiveness,” “systematic review,” and “meta-analysis.” The following databases were searched: PubMed, Cochrane, Google Scholar, and Scopus. Two reviewers evaluated the articles according to the checklist of “assessment of multiple systematic reviews” (AMSTAR) tool. Results: Finally, eight systematic reviews were included in the study. The Drummond checklist was mostly used for assessing the quality of the articles. The main perspective was related to the payer and the least was relevant to the social. The majority of the cases referred to sensitivity analysis (in 76% of the cases) and the lowest point also was allocated to discounting (in 37% of cases). The Markov model was used most widely in the studies. Treatment methods examined in the studies were not cost-effective in comparison with the studied units. Among the screening methods, computerized tomographic colonography and fecal DNA were cost-effective. The average score of the articles’ qualities was high (9.8 out of 11). Conclusions: The community perspective should be taken into consideration at large in the studies. It is necessary to pay more attention to discounting subject in studies. More frequent application of the Markov model is recommended. PMID:29379836

  15. Effects of Multi-Electrode Renal Denervation on Insulin Sensitivity and Glucose Metabolism in a Canine Model of Type 2 Diabetes Mellitus.

    PubMed

    Pan, Tao; Guo, Jin-He; Ling, Long; Qian, Yue; Dong, Yong-Hua; Yin, Hua-Qing; Zhu, Hai-Dong; Teng, Gao-Jun

    2018-05-01

    To evaluate the effects of multi-electrode catheter-based renal denervation (RDN) on insulin sensitivity and glucose metabolism in a type 2 diabetes mellitus (T2DM) canine model. Thirty-three dogs were divided equally into 3 groups: bilateral renal denervation (BRDN) group, left renal denervation (LRDN) group, and sham operation (SHAM) group. Body weight and blood biochemistry were measured at baseline, 20 weeks, and 32 weeks, and renal angiography and computerized tomographic (CT) angiography were determined before the procedure and 1 month, 2 months, and 3 months after the procedure. Western blot was used to identify the activities of gluconeogenic enzymes and insulin-signaling proteins. Fasting plasma glucose (9.64 ± 1.57 mmol/L vs 5.12 ± 1.08 mmol/L; P < .0001), fasting insulin (16.19 ± 1.43 mIU/mL vs 5.07 ± 1.13 mIU/mL; P < .0001), and homeostasis-model assessment of insulin resistance (HOMA-IR; 6.95 ± 1.33 vs 1.15 ± 0.33; P < .0001) in the BRDN group had significantly decreased at the 3-month follow-up compared with the SHAM group. Western blot analyses showed that RDN suppressed the gluconeogenetic genes, modulated insulin action, and activated insulin receptors-AKT signaling cascade in the liver. CT angiography and histopathologic analyses did not show any dissection, aneurysm, thrombus, or rupture in any of the renal arteries. These findings identified that multi-electrode catheter-based RDN could effectively decrease gluconeogenesis and glycogenolysis, resulting in improvements in insulin sensitivity and glucose metabolism in a T2DM canine model. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  16. A computerized faculty time-management system in an academic family medicine department.

    PubMed

    Daugird, Allen J; Arndt, Jane E; Olson, P Richard

    2003-02-01

    The authors describe the development, implementation, and evaluation of a computerized faculty time-management system (FTMS) in the Department of Family Medicine at the University of North Carolina-Chapel Hill. The FTMS is presented as an integrated set of computerized spreadsheets used annually to allocate faculty time across all mission activities of the department. It was first implemented in 1996 and has been continuously developed since then. An iterative approach has been used to gain consensus among faculty about time resources needed for various tasks of all missions of the department. These time-resource assumptions are used in the computerized system. Faculty time is allocated annually by the department vice chair in negotiation with individual faculty, making sure that the activities planned do not exceed the work time each faculty member has available for the year. During this process, faculty preferences are balanced against department aggregate needs to meet mission commitments and obligations. The authors describe how the computerized FTMS is used for faculty time management and career development, department planning, budget planning, clinical scheduling, and mission cost accounting. They also describe barriers and potential abuses and the challenge of building an organizational culture willing to discuss faculty time openly and committed to developing a system perceived as fair and accurate. The spreadsheet file is available free from the authors for use in other departments.

  17. Use of Noncontrast Computed Tomography and Computed Tomographic Perfusion in Predicting Intracerebral Hemorrhage After Intravenous Alteplase Therapy.

    PubMed

    Batchelor, Connor; Pordeli, Pooneh; d'Esterre, Christopher D; Najm, Mohamed; Al-Ajlan, Fahad S; Boesen, Mari E; McDougall, Connor; Hur, Lisa; Fainardi, Enrico; Shankar, Jai Jai Shiva; Rubiera, Marta; Khaw, Alexander V; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Goyal, Mayank; Lee, Ting-Yim; Aviv, Richard I; Menon, Bijoy K

    2017-06-01

    Intracerebral hemorrhage is a feared complication of intravenous alteplase therapy in patients with acute ischemic stroke. We explore the use of multimodal computed tomography in predicting this complication. All patients were administered intravenous alteplase with/without intra-arterial therapy. An age- and sex-matched case-control design with classic and conditional logistic regression techniques was chosen for analyses. Outcome was parenchymal hemorrhage on 24- to 48-hour imaging. Exposure variables were imaging (noncontrast computed tomography hypoattenuation degree, relative volume of very low cerebral blood volume, relative volume of cerebral blood flow ≤7 mL/min·per 100 g, relative volume of T max ≥16 s with all volumes standardized to z axis coverage, mean permeability surface area product values within T max ≥8 s volume, and mean permeability surface area product values within ipsilesional hemisphere) and clinical variables (NIHSS [National Institutes of Health Stroke Scale], onset to imaging time, baseline systolic blood pressure, blood glucose, serum creatinine, treatment type, and reperfusion status). One-hundred eighteen subjects (22 patients with parenchymal hemorrhage versus 96 without, median baseline NIHSS score of 15) were included in the final analysis. In multivariable regression, noncontrast computed tomography hypoattenuation grade ( P <0.006) and computerized tomography perfusion white matter relative volume of very low cerebral blood volume ( P =0.04) were the only significant variables associated with parenchymal hemorrhage on follow-up imaging (area under the curve, 0.73; 95% confidence interval, 0.63-0.83). Interrater reliability for noncontrast computed tomography hypoattenuation grade was moderate (κ=0.6). Baseline hypoattenuation on noncontrast computed tomography and very low cerebral blood volume on computerized tomography perfusion are associated with development of parenchymal hemorrhage in patients with acute ischemic stroke receiving intravenous alteplase. © 2017 American Heart Association, Inc.

  18. Occult fractures of the knee: tomographic evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apple, J.S.; Martinez, S.; Allen, N.B.

    1983-08-01

    Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans maymore » be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture.« less

  19. Coronary Plaque Morphology and the Anti-Inflammatory Impact of Atorvastatin: A Multicenter 18F-Fluorodeoxyglucose Positron Emission Tomographic/Computed Tomographic Study.

    PubMed

    Singh, Parmanand; Emami, Hamed; Subramanian, Sharath; Maurovich-Horvat, Pal; Marincheva-Savcheva, Gergana; Medina, Hector M; Abdelbaky, Amr; Alon, Achilles; Shankar, Sudha S; Rudd, James H F; Fayad, Zahi A; Hoffmann, Udo; Tawakol, Ahmed

    2016-12-01

    Nonobstructive coronary plaques manifesting high-risk morphology (HRM) associate with an increased risk of adverse clinical cardiovascular events. We sought to test the hypothesis that statins have a greater anti-inflammatory effect within coronary plaques containing HRM. In this prospective multicenter study, 55 subjects with or at high risk for atherosclerosis underwent 18 F-fluorodeoxyglucose positron emission tomographic/computed tomographic imaging at baseline and after 12 weeks of treatment with atorvastatin. Coronary arterial inflammation ( 18 F-fluorodeoxyglucose uptake, expressed as target-to-background ratio) was assessed in the left main coronary artery (LMCA). While blinded to the PET findings, contrast-enhanced computed tomographic angiography was performed to characterize the presence of HRM (defined as noncalcified or partially calcified plaques) in the LMCA. Arterial inflammation (target-to-background ratio) was higher in LMCA segments with HRM than those without HRM (mean±SEM: 1.95±0.43 versus 1.67±0.32 for LMCA with versus without HRM, respectively; P=0.04). Moreover, atorvastatin treatment for 12 weeks reduced target-to-background ratio more in LMCA segments with HRM than those without HRM (12 week-baseline Δtarget-to-background ratio [95% confidence interval]: -0.18 [-0.35 to -0.004] versus 0.09 [-0.06 to 0.26]; P=0.02). Furthermore, this relationship between coronary plaque morphology and change in LMCA inflammatory activity remained significant after adjusting for baseline low-density lipoprotein and statin dose (β=-0.27; P=0.038). In this first study to evaluate the impact of statins on coronary inflammation, we observed that the anti-inflammatory impact of statins is substantially greater within coronary plaques that contain HRM features. These findings suggest an additional mechanism by which statins disproportionately benefit individuals with more advanced atherosclerotic disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00703261. © 2016 The Authors.

  20. Can we go From Tomographically Determined Seismic Velocities to Composition? Amplitude Resolution Issues in Local Earthquake Tomography

    NASA Astrophysics Data System (ADS)

    Wagner, L.

    2007-12-01

    There have been a number of recent papers (i.e. Lee (2003), James et al. (2004), Hacker and Abers (2004), Schutt and Lesher (2006)) which calculate predicted velocities for xenolith compositions at mantle pressures and temperatures. It is tempting, therefore, to attempt to go the other way ... to use tomographically determined absolute velocities to constrain mantle composition. However, in order to do this, it is vital that one is able to accurately constrain not only the polarity of the determined velocity deviations (i.e. fast vs slow) but also how much faster, how much slower relative to the starting model, if absolute velocities are to be so closely analyzed. While much attention has been given to issues concerning spatial resolution in seismic tomography (i.e. what areas are fast, what areas are slow), little attention has been directed at the issue of amplitude resolution (how fast, how slow). Velocity deviation amplitudes in seismic tomography are heavily influenced by the amount of regularization used and the number of iterations performed. Determining these two parameters is a difficult and little discussed problem. I explore the effect of these two parameters on the amplitudes obtained from the tomographic inversion of the Chile Argentina Geophysical Experiment (CHARGE) dataset, and attempt to determine a reasonable solution space for the low Vp, high Vs, low Vp/Vs anomaly found above the flat slab in central Chile. I then compare this solution space to the range in experimentally determined velocities for peridotite end-members to evaluate our ability to constrain composition using tomographically determined seismic velocities. I find that in general, it will be difficult to constrain the compositions of normal mantle peridotites using tomographically determined velocities, but that in the unusual case of the anomaly above the flat slab, the observed velocity structure still has an anomalously high S wave velocity and low Vp/Vs ratio that is most consistent with enstatite, but inconsistent with the predicted velocities of known mantle xenoliths.

  1. Evaluation of data requirements for computerized constructability analysis of pavement rehabilitation projects.

    DOT National Transportation Integrated Search

    2013-08-01

    This research aimed to evaluate the data requirements for computer assisted construction planning : and staging methods that can be implemented in pavement rehabilitation projects in the state of : Georgia. Results showed that two main issues for the...

  2. Diagnostic Accuracy of Periapical Radiography and Cone-beam Computed Tomography in Identifying Root Canal Configuration of Human Premolars.

    PubMed

    Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam

    2017-07-01

    The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Orthodontic decompensation in skeletal Class III malocclusion: redefining the amount of movement assessed by Cone-Beam Computed Tomography

    PubMed Central

    Cappellozza, José Antonio Zuega; Guedes, Fabio Pinto; Nary, Hugo; Capelozza, Leopoldino; Cardoso, Mauricio de Almeida

    2015-01-01

    Introduction: Cone-Beam Computed Tomography (CBCT) is essential for tridimensional planning of orthognathic surgery, as it allows visualization and evaluation of bone structures and mineralized tissues. Tomographic slices allow evaluation of tooth inclination and individualization of movement performed during preoperative decompensation. The aim of this paper was to assess maxillary and mandibular incisors inclination pre and post orthodontic decompensation in skeletal Class III malocclusion. Methods: The study was conducted on six individuals with skeletal Class III malocclusion, surgically treated, who had Cone-Beam Computed Tomographic scans obtained before and after orthodontic decompensation. On multiplanar reconstruction view, tomographic slices (axial, coronal and sagittal) were obtained on the long axis of each incisor. The sagittal slice was used for measurement taking, whereas the references used to assess tooth inclination were the long axis of maxillary teeth in relation to the palatal plane and the long axis of mandibular teeth in relation to the mandibular plane. Results: There was significant variation in the inclination of incisors before and after orthodontic decompensation. This change was of greater magnitude in the mandibular arch, evidencing that natural compensation is more effective in this arch, thereby requiring more intensive decompensation. Conclusion: When routinely performed, the protocols of decompensation treatment in surgical individuals often result in intensive movements, which should be reevaluated, since the extent of movement predisposes to reduction in bone attachment levels and root length. PMID:26560818

  4. Effect of Donepezil on Wernicke Aphasia After Bilateral Middle Cerebral Artery Infarction: Subtraction Analysis of Brain F-18 Fluorodeoxyglucose Positron Emission Tomographic Images.

    PubMed

    Yoon, Seo Yeon; Kim, Je-Kyung; An, Young-Sil; Kim, Yong Wook

    2015-01-01

    Aphasia is one of the most common neurologic deficits occurring after stroke. Although the speech-language therapy is a mainstream option for poststroke aphasia, pharmacotherapy is recently being tried to modulate different neurotransmitter systems. However, the efficacy of those treatments is still controversial. We present a case of a 53-year-old female patient with Wernicke aphasia, after the old infarction in the territory of left middle cerebral artery for 8 years and the recent infarction in the right middle cerebral artery for 4 months. On the initial evaluation, the Aphasia Quotient in Korean version of the Western Aphasia Battery was 25.6 of 100. Baseline brain F-18 fluorodeoxyglucose positron emission tomographic images demonstrated a decreased cerebral metabolism in the left temporoparietal area and right temporal lobe. Donepezil hydrochloride, a reversible acetylcholinesterase inhibitor, was orally administered 5 mg/d for 6 weeks after the initial evaluation and was increased to 10 mg/d for the following 6 weeks. After the donepezil treatment, the patient showed improvement in language function, scoring 51.0 of 100 on Aphasia Quotient. A subtraction analysis of the brain F-18 fluorodeoxyglucose positron emission tomographic images after donepezil medication demonstrated increased uptake in both middle temporal gyri, extended to the occipital area and the left cerebellum. Thus, we suggest that donepezil can be an effective therapeutic choice for the treatment of Wernicke aphasia.

  5. Tomographic Imaging of a Forested Area By Airborne Multi-Baseline P-Band SAR.

    PubMed

    Frey, Othmar; Morsdorf, Felix; Meier, Erich

    2008-09-24

    In recent years, various attempts have been undertaken to obtain information about the structure of forested areas from multi-baseline synthetic aperture radar data. Tomographic processing of such data has been demonstrated for airborne L-band data but the quality of the focused tomographic images is limited by several factors. In particular, the common Fourierbased focusing methods are susceptible to irregular and sparse sampling, two problems, that are unavoidable in case of multi-pass, multi-baseline SAR data acquired by an airborne system. In this paper, a tomographic focusing method based on the time-domain back-projection algorithm is proposed, which maintains the geometric relationship between the original sensor positions and the imaged target and is therefore able to cope with irregular sampling without introducing any approximations with respect to the geometry. The tomographic focusing quality is assessed by analysing the impulse response of simulated point targets and an in-scene corner reflector. And, in particular, several tomographic slices of a volume representing a forested area are given. The respective P-band tomographic data set consisting of eleven flight tracks has been acquired by the airborne E-SAR sensor of the German Aerospace Center (DLR).

  6. A study of commuter airplane design optimization

    NASA Technical Reports Server (NTRS)

    Keppel, B. V.; Eysink, H.; Hammer, J.; Hawley, K.; Meredith, P.; Roskam, J.

    1978-01-01

    The usability of the general aviation synthesis program (GASP) was enhanced by the development of separate computer subroutines which can be added as a package to this assembly of computerized design methods or used as a separate subroutine program to compute the dynamic longitudinal, lateral-directional stability characteristics for a given airplane. Currently available analysis methods were evaluated to ascertain those most appropriate for the design functions which the GASP computerized design program performs. Methods for providing proper constraint and/or analysis functions for GASP were developed as well as the appropriate subroutines.

  7. Computerized measurement and analysis of scoliosis: a more accurate representation of the shape of the curve.

    PubMed

    Jeffries, B F; Tarlton, M; De Smet, A A; Dwyer, S J; Brower, A C

    1980-02-01

    A computer program was created to identify and accept spatial data regarding the location of the thoracic and lumbar vertebral bodies on scoliosis films. With this information, the spine can be mathematically reconstructed and a scoliotic angle calculated. There was a 0.968 positive correlation between the computer and manual methods of measuring scoliosis. The computer method was more reproducible with a standard deviation of only 1.3 degrees. Computerized measurement of scoliosis also provides better evaluation of the true shape of the curve.

  8. Phenomenology study of HERMES ground-penetrating radar technology for detection and identification of common bridge deck features

    DOT National Transportation Integrated Search

    2001-06-01

    Accurately evaluating the condition of a bridge deck over time and using this information to choose appropriate maintenance techniques has become critical for the efficient allocation of resources to bridge deck maintenance. Tomographic imaging of su...

  9. A method of measuring anterior chamber volume using the anterior segment optical coherence tomographer and specialized software.

    PubMed

    Wang, Ningli; Wang, Bingsong; Zhai, Gaoshou; Lei, Kun; Wang, Lan; Congdon, Nathan

    2007-05-01

    To describe and evaluate a new method for measuring anterior chamber volume (ACV). Observational case series. The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. The ACV values obtained by this method were repeatable and in accord with clinical observation.

  10. A cost-utility analysis of the use of preoperative computed tomographic angiography in abdomen-based perforator flap breast reconstruction.

    PubMed

    Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei

    2015-04-01

    Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.

  11. Heuristic Evaluation and Usability Testing of a Computerized Patient-Reported Outcomes Survey for Headache Sufferers

    PubMed Central

    Saris-Baglama, Renee N.; Smith, Kevin J.; DeRosa, Michael A.; Paulsen, Christine A.; Hogue, Sarah J.

    2011-01-01

    Abstract Objective The aim of this study was to evaluate usability of a prototype tablet PC-administered computerized adaptive test (CAT) of headache impact and patient feedback report, referred to as HEADACHE-CAT. Materials and Methods Heuristic evaluation specialists (n = 2) formed a consensus opinion on the application's strengths and areas for improvement based on general usability principles and human factors research. Usability testing involved structured interviews with headache sufferers (n = 9) to assess how they interacted with and navigated through the application, and to gather input on the survey and report interface, content, visual design, navigation, instructions, and user preferences. Results Specialists identified the need for improved instructions and text formatting, increased font size, page setup that avoids scrolling, and simplified presentation of feedback reports. Participants found the tool useful, and indicated a willingness to complete it again and recommend it to their healthcare provider. However, some had difficulty using the onscreen keyboard and autoadvance option; understanding the difference between generic and headache-specific questions; and interpreting score reports. Conclusions Heuristic evaluation and user testing can help identify usability problems in the early stages of application development, and improve the construct validity of electronic assessments such as the HEADACHE-CAT. An improved computerized HEADACHE-CAT measure can offer headache sufferers an efficient tool to increase patient self-awareness, monitor headaches over time, aid patient–provider communications, and improve quality of life. PMID:21214341

  12. Evaluation of a Computerized Clinical Information System (Micromedex).

    PubMed Central

    Lundsgaarde, H. P.; Moreshead, G. E.

    1991-01-01

    This paper summarizes data collected as part of a project designed to identify and assess the technical and organizational problems associated with the implementation and evaluation of a Computerized Clinical Information System (CCIS), Micromedex, in three U.S. Department of Veterans Affairs Medical Centers (VAMCs). The study began in 1987 as a national effort to implement decision support technologies in the Veterans Administration Decentralized Hospital Computer Program (DHCP). The specific objectives of this project were to (1) examine one particular decision support technology, (2) identify the technical and organizational barriers to the implementation of a CCIS in the VA host environment, (3) assess the possible benefits of this system to VA clinicians in terms of therapeutic decision making, and (4) develop new methods for identifying the clinical utility of a computer program designed to provide clinicians with a new information tool. The project was conducted intermittently over a three-year period at three VA medical centers chosen as implementation and evaluation test sites for Micromedex. Findings from the Kansas City Medical Center in Missouri are presented to illustrate some of the technical problems associated with the implementation of a commercial database program in the DHCP host environment, the organizational factors influencing clinical use of the system, and the methods used to evaluate its use. Data from 4581 provider encounters with the CCIS are summarized. Usage statistics are presented to illustrate the methodological possibilities for assessing the "benefits and burdens" of a computerized information system by using an automated collection of user demographics and program audit trails that allow evaluators to monitor user interactions with different segments of the database. PMID:1807583

  13. Evaluation of a Computerized Clinical Information System (Micromedex).

    PubMed

    Lundsgaarde, H P; Moreshead, G E

    1991-01-01

    This paper summarizes data collected as part of a project designed to identify and assess the technical and organizational problems associated with the implementation and evaluation of a Computerized Clinical Information System (CCIS), Micromedex, in three U.S. Department of Veterans Affairs Medical Centers (VAMCs). The study began in 1987 as a national effort to implement decision support technologies in the Veterans Administration Decentralized Hospital Computer Program (DHCP). The specific objectives of this project were to (1) examine one particular decision support technology, (2) identify the technical and organizational barriers to the implementation of a CCIS in the VA host environment, (3) assess the possible benefits of this system to VA clinicians in terms of therapeutic decision making, and (4) develop new methods for identifying the clinical utility of a computer program designed to provide clinicians with a new information tool. The project was conducted intermittently over a three-year period at three VA medical centers chosen as implementation and evaluation test sites for Micromedex. Findings from the Kansas City Medical Center in Missouri are presented to illustrate some of the technical problems associated with the implementation of a commercial database program in the DHCP host environment, the organizational factors influencing clinical use of the system, and the methods used to evaluate its use. Data from 4581 provider encounters with the CCIS are summarized. Usage statistics are presented to illustrate the methodological possibilities for assessing the "benefits and burdens" of a computerized information system by using an automated collection of user demographics and program audit trails that allow evaluators to monitor user interactions with different segments of the database.

  14. Developing an evidence base of best practices for integrating computerized systems into the exam room: a systematic review.

    PubMed

    Patel, Minal R; Vichich, Jennifer; Lang, Ian; Lin, Jessica; Zheng, Kai

    2017-04-01

    The introduction of health information technology systems, electronic health records in particular, is changing the nature of how clinicians interact with patients. Lack of knowledge remains on how best to integrate such systems in the exam room. The purpose of this systematic review was to (1) distill "best" behavioral and communication practices recommended in the literature for clinicians when interacting with patients in the presence of computerized systems during a clinical encounter, (2) weigh the evidence of each recommendation, and (3) rank evidence-based recommendations for electronic health record communication training initiatives for clinicians. We conducted a literature search of 6 databases, resulting in 52 articles included in the analysis. We extracted information such as study setting, research design, sample, findings, and implications. Recommendations were distilled based on consistent support for behavioral and communication practices across studies. Eight behavioral and communication practices received strong support of evidence in the literature and included specific aspects of using computerized systems to facilitate conversation and transparency in the exam room, such as spatial (re)organization of the exam room, maintaining nonverbal communication, and specific techniques that integrate the computerized system into the visit and engage the patient. Four practices, although patient-centered, have received insufficient evidence to date. We developed an evidence base of best practices for clinicians to maintain patient-centered communications in the presence of computerized systems in the exam room. Further work includes development and empirical evaluation of evidence-based guidelines to better integrate computerized systems into clinical care. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  15. The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.

    PubMed

    Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne

    2014-06-01

    Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Computerized symptom and quality-of-life assessment for patients with cancer part II: acceptability and usability.

    PubMed

    Mullen, Kristin H; Berry, Donna L; Zierler, Brenda K

    2004-09-01

    To determine the acceptability and usability of a computerized quality-of-life (QOL) and symptom assessment tool and the graphically displayed QOL and symptom output in an ambulatory radiation oncology clinic. Descriptive, cross-sectional. Radiation oncology clinic located in an urban university medical center. 45 patients with cancer being evaluated for radiation therapy and 10 clinicians, who submitted 12 surveys. Acceptability of the computerized assessment was measured with an online, 16-item, Likert-style survey delivered as 45 patients undergoing radiation therapy completed a 25-item QOL and symptom assessment. Usability of the graphic output was assessed with clinician completion of a four-item paper survey. Acceptability and usability of computerized patient assessment. The patient acceptability survey indicated that 70% (n = 28) liked computers and 10% (n = 4) did not. The program was easy to use for 79% (n = 26), easy to understand for 91% (n = 30), and enjoyable for 71% (n = 24). Seventy-six percent (n = 25) believed that the amount of time needed to complete the computerized survey was acceptable. Sixty-six percent (n = 21) responded that they were satisfied with the program, and none of the participants chose the very dissatisfied response. Eighty-three percent (n = 10) of the clinicians found the graphic output helpful in promoting communication with patients, 75% (n = 9) found the output report helpful in identifying appropriate areas of QOL deficits or concerns, and 83% (n = 10) indicated that the output helped guide clinical interactions with patients. The computer-based QOL and symptom assessment tool is acceptable to patients, and the graphically displayed QOL and symptom output is useful to radiation oncology nurses and physicians. Wider application of computerized patient-generated data can continue in various cancer settings and be tested for clinical and organizational outcomes.

  17. Sources of Information for Evaluating Rural Development: An Overview.

    ERIC Educational Resources Information Center

    Grayburn, Laura; And Others

    Designed to help rural development evaluators and other social scientists use their bibliographic search time more efficiently, this information guide presents the following: (1) detailed information on computerized information retrieval systems, including name, location, subject matter, turnaround time, cost, availability, and utility…

  18. Computerized stroop test to assess selective attention in children with attention deficit hyperactivity disorder.

    PubMed

    Assef, Ellen Carolina dos Santos; Capovilla, Alessandra Gotuzo Seabra; Capovilla, Fernando Cesar

    2007-05-01

    Research shows abnormal function of the pre-frontal cortex in Attention Deficit Hyperactivity Disorder (ADHD). This cortex is involved in the control of executive functions related to planning and execution of goal-oriented strategies, working memory, inhibitions, cognitive flexibility, and selective attention. Selective attention involves focus on the target stimulus, ignoring competing distractions. The Stroop Test (Stroop, 1935) is usually used to evaluate selective attention. This study investigated whether children with ADHD could exhibit modified performance in the Stroop Test. Using a computerized version of this test (Capovilla, Montiel, Macedo, & Charin, 2005), the study compared the reaction times (RTs) of 62 Brazilian children, between 8 and 12 years of age, 31 of whom were diagnosed with ADHD and sent to psychiatric clinics, and 31 without ADHD studying in regular schools. All children with ADHD satisfied the criteria of the DSM-IV-TR and were evaluated with the Conners Abbreviated Questionnaire (Goyette, Conners, & Ulrich, 1978), completed by parents and teachers. The results revealed that children with ADHD exhibit greater interference in RT than children without ADHD. This corroborated the hypothesis that children with ADHD exhibit a deficit in selective attention, consisting in augmented RTs, as measured by the Computerized Stroop Test.

  19. [Use of computerized stabylometric footboard in evaluation of work suitability at height work in building firms].

    PubMed

    D'Orso, M I; Garaguso, M; Ferrari, G; Riva, M A; Gallamini, M; Cesana, G

    2012-01-01

    A relevant part of deadly work accidents and of severe work accidents reported in national specific statistics coming from INAIL is until today caused by workers' falls during their at height work activities. Medical evaluation of eventual workers' hyper susceptibility to fall caused by balance alterations, if included in medical surveillance, is frequently carried out by medical doctors using different subjective tests included in different clinical protocols. Use of a computerized stabylometric footboard on the contrary allows to obtain objective and reproducible data concerning vestibular function which, associated with traditional clinical medical evaluation, seem to better detect eventual presence of balance disturbances, especially those non clinically perceivable by workers and therefore more dangerous. We report results evidenced in a research carried out in a group of 185 workers engaged in building firms and having work tasks including phases of at height work.

  20. Analysis of internal and external validity criteria for a computerized visual search task: A pilot study.

    PubMed

    Richard's, María M; Introzzi, Isabel; Zamora, Eliana; Vernucci, Santiago

    2017-01-01

    Inhibition is one of the main executive functions, because of its fundamental role in cognitive and social development. Given the importance of reliable and computerized measurements to assessment inhibitory performance, this research intends to analyze the internal and external criteria of validity of a computerized conjunction search task, to evaluate the role of perceptual inhibition. A sample of 41 children (21 females and 20 males), aged between 6 and 11 years old (M = 8.49, SD = 1.47), intentionally selected from a private management school of Mar del Plata (Argentina), middle socio-economic level were assessed. The Conjunction Search Task from the TAC Battery, Coding and Symbol Search tasks from Wechsler Intelligence Scale for Children were used. Overall, results allow us to confirm that the perceptual inhibition task form TAC presents solid rates of internal and external validity that make a valid measurement instrument of this process.

  1. Computerized bioterrorism education and training for nurses on bioterrorism attack agents.

    PubMed

    Nyamathi, Adeline M; Casillas, Adrian; King, Major L; Gresham, Louise; Pierce, Elaine; Farb, Daniel; Wiechmann, Carrie; Weichmann, Carrie

    2010-08-01

    Biological agents have the ability to cause large-scale mass casualties. For this reason, their likely use in future terrorist attacks is a concern for national security. Recent studies show that nurses are ill prepared to deal with agents used in biological warfare. Achieving a goal for bioterrorism preparedness is directly linked to comprehensive education and training that enables first-line responders such as nurses to diagnose infectious agents rapidly. The study evaluated participants' responses to biological agents using a computerized bioterrorism education and training program versus a standard bioterrorism education and training program. Both programs improved participants' ability to complete and solve case studies involving the identification of specific biological agents. Participants in the computerized bioterrorism education and training program were more likely to solve the cases critically without reliance on expert consultants. However, participants in the standard bioterrorism education and training program reduced the use of unnecessary diagnostic tests.

  2. Surface Wave Tomography with Spatially Varying Smoothing Based on Continuous Model Regionalization

    NASA Astrophysics Data System (ADS)

    Liu, Chuanming; Yao, Huajian

    2017-03-01

    Surface wave tomography based on continuous regionalization of model parameters is widely used to invert for 2-D phase or group velocity maps. An inevitable problem is that the distribution of ray paths is far from homogeneous due to the spatially uneven distribution of stations and seismic events, which often affects the spatial resolution of the tomographic model. We present an improved tomographic method with a spatially varying smoothing scheme that is based on the continuous regionalization approach. The smoothness of the inverted model is constrained by the Gaussian a priori model covariance function with spatially varying correlation lengths based on ray path density. In addition, a two-step inversion procedure is used to suppress the effects of data outliers on tomographic models. Both synthetic and real data are used to evaluate this newly developed tomographic algorithm. In the synthetic tests, when the contrived model has different scales of anomalies but with uneven ray path distribution, we compare the performance of our spatially varying smoothing method with the traditional inversion method, and show that the new method is capable of improving the recovery in regions of dense ray sampling. For real data applications, the resulting phase velocity maps of Rayleigh waves in SE Tibet produced using the spatially varying smoothing method show similar features to the results with the traditional method. However, the new results contain more detailed structures and appears to better resolve the amplitude of anomalies. From both synthetic and real data tests we demonstrate that our new approach is useful to achieve spatially varying resolution when used in regions with heterogeneous ray path distribution.

  3. Preliminary evaluation of a micro-based repeated measures testing system

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  4. Contributions to Objective Measurement and Evaluation of Trainee Competency.

    ERIC Educational Resources Information Center

    Moonan, William J.

    The purpose of this paper is to lay a basis for and discuss the components of a system, called COMET, designed to objectively measure and evaluate the competency of trainees in military training enterprises. COMET is an acronym for "Computerized Objective Measurement and Evaluation of Trainees." These goals will be accomplished by: (a)…

  5. Towards a Better Understanding of the Legibility Bias in Performance Assessments: The Case of Gender-Based Inferences

    ERIC Educational Resources Information Center

    Greifeneder, Rainer; Zelt, Sarah; Seele, Tim; Bottenberg, Konstantin; Alt, Alexander

    2012-01-01

    Background: Handwriting legibility systematically biases evaluations in that highly legible handwriting results in more positive evaluations than less legible handwriting. Because performance assessments in educational contexts are not only based on computerized or multiple choice tests but often include the evaluation of handwritten work samples,…

  6. Identification of Target Complaints by Computer Interview: Evaluation of the Computerized Assessment System for Psychotherapy Evaluation and Research.

    ERIC Educational Resources Information Center

    Farrell, Albert D.; And Others

    1987-01-01

    Evaluated computer interview to standardize collection of target complaints. Adult outpatients (N=103) completed computer interview, unstructured intake interview, Symptoms Checklist-90, and Minnesota Multiphasic Personality Inventory. Results provided support for the computer interview in regard to reliability and validity though there was low…

  7. Evaluating and selecting an information system, Part 1.

    PubMed

    Neal, T

    1993-01-01

    Initial steps in the process of evaluating and selecting a computerized information system for the pharmacy department are described. The first step in the selection process is to establish a steering committee and a project committee. The steering committee oversees the project, providing policy guidance, making major decisions, and allocating budgeted expenditures. The project committee conducts the departmental needs assessment, identifies system requirements, performs day-to-day functions, evaluates vendor proposals, trains personnel, and implements the system chosen. The second step is the assessment of needs in terms of personnel, workload, physical layout, and operating requirements. The needs assessment should be based on the department's mission statement and strategic plan. The third step is the development of a request for information (RFI) and a request for proposal (RFP). The RFI is a document designed for gathering preliminary information from a wide range of vendors; this general information is used in deciding whether to send the RFP to a given vendor. The RFP requests more detailed information and gives the purchaser's exact specifications for a system; the RFP also includes contractual information. To help ensure project success, many institutions turn to computer consultants for guidance. The initial steps in selecting a computerized pharmacy information system are establishing computerization committees, conducting a needs assessment, and writing an RFI and an RFP. A crucial early decision is whether to seek a consultant's expertise.

  8. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abraham, I., E-mail: isabelle.abraham@cea.fr; Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  9. Computer-Based Oral Hygiene Instruction versus Verbal Method in Fixed Orthodontic Patients

    PubMed Central

    Moshkelgosha, V.; Mehrvarz, Sh.; Saki, M.; Golkari, A.

    2017-01-01

    Statement of Problem: Fixed orthodontic appliances in the oral cavity make tooth cleaning procedures more complicated. Objectives: This study aimed to compare the efficacy of computerized oral hygiene instruction with verbal technique among fixed orthodontic patients referred to the evening clinic of Orthodontics of Shiraz Dental School. Materials and Methods: A single-blind study was performed in Orthodontic Department of Shiraz, Islamic Republic of Iran, from January to May 2015 following the demonstrated exclusion and inclusion criteria. The sample size was considered 60 patients with 30 subjects in each group. Bleeding on probing and plaque indices and dental knowledge were assessed in the subjects to determine pre-intervention status. A questionnaire was designed for dental knowledge evaluation. The patients were randomly assigned into the computerized and verbal groups. Three weeks after the oral hygiene instruction, indices of bleeding on probing and plaque index and the dental knowledge were evaluated to investigate post-intervention outcome. The two groups were compared by chi-square and student t tests. The pre- and post-intervention scores in each group were compared using paired t-test. Results: In the computerized group, the mean score for plaque index and bleeding on probing index was significantly decreased while dental health knowledge was significantly increased after oral hygiene instruction, in contrast to the verbal group. Conclusions: Within the limitations of the current study, computerized oral hygiene instruction is proposed to be more effective in providing optimal oral health status compared to the conventional method in fixed orthodontic patients. PMID:28959765

  10. Using Computerized Cytomorphometry to Distinguish between Benign and Malignant Cases in Thyroid Fine-Needle Aspiration Cytology.

    PubMed

    Celik, Zeliha Esin; Altinay, Serdar; Kilinc, Fahriye; Arslan, Nur; Yilmaz, Burcu Sanal; Karabagli, Pınar; Ugurluoglu, Ceyhan

    2016-11-01

    Only a small number of studies on computerized cytomorphometry have been performed for thyroid FNAC. The present study aimed to determine the usefulness of computerized cytomorphometry methods to further classify thyroid lesions as benign or malignant and to compare the practicability and value of using Papanicolaou (Pap) and Giemsa stains in thyroid FNAC by evaluating their association to various cytologic nuclear parameters. Fifty-eight thyroid lesions diagnosed by FNAC and categorized according to the Bethesda system for reporting thyroid cytopathology were evaluated in terms of various cytologic nuclear parameters, including nuclear area (NA), nuclear perimeter (NP), nuclear density (ND), long nuclear diameter (LND), and short nuclear diameter (SND). The Pap- and Giemsa-stained slides were examined separately. In the malignant cases, NA, NP, LND, and SND were higher than in the benign cases for both the Pap and Giemsa stains. NA, NP, LND, and SND were higher in Giemsa than Pap for both the benign and malignant groups. Statistically significant differences were detected between the benign and malignant cases in the AUS category. Computerized cytomorphometry is useful in distinguishing between benign and malignant lesions in thyroid FNAC. The measurement of cytologic nuclear parameters in cases suggestive of AUS may be useful for the probable classification of cases as benign or malignant. Although further studies are needed, in nuclear morphometric assessment of thyroid FNAC, Giemsa staining may be more useful and valuable than the Pap stain because of its association with various cytologic nuclear parameters. Diagn. Cytopathol. 2016;44:902-911. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Computerized cognitive behavioural therapy at work: a randomized controlled trial in employees with recent stress-related absenteeism.

    PubMed

    Grime, Paul R

    2004-08-01

    Emotional distress has major implications for employees and employers. Cognitive behavioural therapy (CBT) is a recommended treatment, but demand outstrips supply. CBT is well suited to computerization. Most employee assistance programmes have not been systematically evaluated and computerized CBT has not previously been studied in the workplace. To evaluate the effect of an 8 week computerized cognitive behavioural therapy programme, 'Beating The Blues', on emotional distress in employees with recent stress-related absenteeism, and to explore the reasons for non-participation. An open, randomized trial in a London NHS occupational health department. Forty-eight public sector employees, with 10 or more cumulative days stress-related absenteeism in the last 6 months, randomized equally to 'Beating The Blues' plus conventional care, or conventional care alone. Main outcome measures were Hospital Anxiety and Depression Scale and Attributional Style Questionnaire scores at end of treatment and 1, 3 and 6 months later; and reasons for non-participation. At end of treatment and 1 month later, adjusted mean depression scores and adjusted mean negative attributional style scores were significantly lower in the intervention group. One month post-treatment, adjusted mean anxiety scores were also significantly lower in the intervention group. The differences were not statistically significant at 3 and 6 months post-treatment. Non-participation was common and related to access problems, preference for other treatments, time commitment, scepticism about the intervention and the employer connection. 'Beating The Blues' may accelerate psychological recovery in employees with recent stress-related absenteeism. Greater flexibility and accessibility might improve uptake.

  12. The Development of MUMPS-Based Rehabilitation Psychology Computer Applications.

    ERIC Educational Resources Information Center

    Dutro, Kenneth R.

    The use of computer assisted programs in career exploration and occupational information is well documented. Various phases of the vocational counseling process, i.e., diagnostic evaluation, program planning, career exploration, case management, and program evaluation, offer similarly promising opportunities for computerization. Using the…

  13. COMPUTERIZED NEEDS-ORIENTED QUALITY MEASUREMENT EVALUATION SYSTEM (CONQUEST)

    EPA Science Inventory

    CONQUEST is an easy-to-use quality improvement software tool that uses a common structure and language to help users identity, understand, compare, evaluate, and select among 1,200 clinical performance measures that can be used to assess and improve quality of care. CONQUEST's in...

  14. How does electromagnetic navigation stack up against infrared navigation in minimally invasive total knee arthroplasties?

    PubMed

    Lionberger, David R; Weise, Jennifer; Ho, David M; Haddad, John L

    2008-06-01

    Forty-six primary total knee arthroplasties were performed using either an electromagnetic (EM) or infrared (IR) navigation system. In this IRB-approved study, patients were evaluated clinically and for accuracy using spiral computed tomographic imaging and 36-in standing radiographs. Although EM navigation was subject to metal interference, it was not as drastic as line-of-sight interference with IR navigation. Mechanical alignment was ideal in 92.9% of EM and 90.0% of IR cases based on spiral computed tomographic imaging and 100% of EM and 95% of IR cases based on x-ray. Individual measurements of component varus/valgus and sagittal measurements showed EM to be equivalent to IR, with both systems producing subdegree accuracy in 95% of the readings.

  15. Reflecting on the ethical administration of computerized medical records

    NASA Astrophysics Data System (ADS)

    Collmann, Jeff R.

    1995-05-01

    This presentation examines the ethical issues raised by computerized image management and communication systems (IMAC), the ethical principals that should guide development of policies, procedures and practices for IMACS systems, and who should be involved in developing a hospital's approach to these issues. The ready access of computerized records creates special hazards of which hospitals must beware. Hospitals must maintain confidentiality of patient's records while making records available to authorized users as efficiently as possible. The general conditions of contemporary health care undermine protecting the confidentiality of patient record. Patients may not provide health care institutions with information about themselves under conditions of informed consent. The field of information science must design sophisticated systems of computer security that stratify access, create audit trails on data changes and system use, safeguard patient data from corruption, and protect the databases from outside invasion. Radiology professionals must both work with information science experts in their own hospitals to create institutional safeguards and include the adequacy of security measures as a criterion for evaluating PACS systems. New policies and procedures on maintaining computerized patient records must be developed that obligate all members of the health care staff, not just care givers. Patients must be informed about the existence of computerized medical records, the rules and practices that govern their dissemination and given the opportunity to give or withhold consent for their use. Departmental and hospital policies on confidentiality should be reviewed to determine if revisions are necessary to manage computer-based records. Well developed discussions of the ethical principles and administrative policies on confidentiality and informed consent and of the risks posed by computer-based patient records systems should be included in initial and continuing staff system training. Administration should develop ways to monitor staff compliance with confidentiality policies and should assess diligence in maintaining patient record confidentiality as part of staff annual performance evaluations. Ethical management of IMAC systems is the business of all members of the health care team. Computerized patient records management (including IMAC) should be scrutinized as any other clinical medial ethical issue. If hospitals include these processes in their planning for RIS, IMACS, and HIS systems, they should have time to develop institutional expertise on these questions before and as systems are installed rather than only as ethical dilemmas develop during their use.

  16. D-WISE: Diabetes Web-Centric Information and Support Environment: conceptual specification and proposed evaluation.

    PubMed

    Abidi, Samina; Vallis, Michael; Raza Abidi, Syed Sibte; Piccinini-Vallis, Helena; Imran, Syed Ali

    2014-06-01

    To develop and evaluate Diabetes Web-Centric Information and Support Environment (D-WISE) that offers 1) a computerized decision-support system to assist physicians to A) use the Canadian Diabetes Association clinical practice guidelines (CDA CPGs) to recommend evidence-informed interventions; B) offer a computerized readiness assessment strategy to help physicians administer behaviour-change strategies to help patients adhere to disease self-management programs; and 2) a patient-specific diabetes self-management application, accessible through smart mobile devices, that offers behaviour-change interventions to engage patients in self-management. The above-mentioned objectives were pursued through a knowledge management approach that involved 1) Translation of paper-based CDA CPGs and behaviour-change models as computerized decision-support tools that will assist physicians to offer evidence-informed and personalized diabetes management and behaviour-change strategies; 2) Engagement of patients in their diabetes care by generating a diabetes self-management program that takes into account their preferences, challenges and needs; 3) Empowering patients to self-manage their condition by providing them with personalized educational and motivational messages through a mobile self-management application. The theoretical foundation of our research is grounded in behaviour-change models and healthcare knowledge management. We used 1) knowledge modelling to computerize the paper-based CDA CPGs and behaviour-change models, in particular, the behaviour-change strategy elements of A) readiness-to-change assessments; B) motivation-enhancement interventions categorized along the lines of patients' being ready, ambivalent or not ready; and C) self-efficacy enhancement. The CDA CPGs and the behaviour-change models are modelled and computerized in terms of A) a diabetes management ontology that serves as the knowledge resource for all the services offered by D-WISE; B) decision support services that use logic-based reasoning algorithms to utilize the knowledge encoded within the diabetes management ontology to assist physicians by recommending patient-specific diabetes-management interventions and behaviour-change strategies; C) a mobile diabetes self-management application to engage and educate diabetes patients to self-manage their condition in a home-based setting while working in concert with their family physicians. We have been successful in creating and conducting a usability assessment of the physician decision support tool. These results will be published once the patient self- management application has been evaluated. D-WISE will be evaluated through pilot studies measuring 1) the usability of the e-Health interventions; and 2) the impact of the interventions on patients' behaviour changes and diabetes control. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  17. Integrated Psychosocial and Opioid-Antagonist Treatment for Alcohol Dependence: A Systematic Review of Controlled Evaluations

    ERIC Educational Resources Information Center

    Vaughn, Michael G.; Howard, Matthew O.

    2004-01-01

    Methodological characteristics and outcomes of 14 controlled clinical investigations of integrated psychosocial and opioid-antagonist alcohol dependence treatment were evaluated. The 14 studies were identified through computerized bibliographic and manual literature searches. Clients receiving integrated psychosocial and opioid-antagonist…

  18. Mapping the vascular anatomy of free transplanted soft tissue flaps with computed tomographic angiography.

    PubMed

    Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R

    2012-05-01

    The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011

  19. Brainstem auditory-evoked potentials as an objective tool for evaluating hearing dysfunction in traumatic brain injury.

    PubMed

    Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F

    2004-03-01

    Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.

  20. Automated classification of brain tumor type in whole-slide digital pathology images using local representative tiles.

    PubMed

    Barker, Jocelyn; Hoogi, Assaf; Depeursinge, Adrien; Rubin, Daniel L

    2016-05-01

    Computerized analysis of digital pathology images offers the potential of improving clinical care (e.g. automated diagnosis) and catalyzing research (e.g. discovering disease subtypes). There are two key challenges thwarting computerized analysis of digital pathology images: first, whole slide pathology images are massive, making computerized analysis inefficient, and second, diverse tissue regions in whole slide images that are not directly relevant to the disease may mislead computerized diagnosis algorithms. We propose a method to overcome both of these challenges that utilizes a coarse-to-fine analysis of the localized characteristics in pathology images. An initial surveying stage analyzes the diversity of coarse regions in the whole slide image. This includes extraction of spatially localized features of shape, color and texture from tiled regions covering the slide. Dimensionality reduction of the features assesses the image diversity in the tiled regions and clustering creates representative groups. A second stage provides a detailed analysis of a single representative tile from each group. An Elastic Net classifier produces a diagnostic decision value for each representative tile. A weighted voting scheme aggregates the decision values from these tiles to obtain a diagnosis at the whole slide level. We evaluated our method by automatically classifying 302 brain cancer cases into two possible diagnoses (glioblastoma multiforme (N = 182) versus lower grade glioma (N = 120)) with an accuracy of 93.1% (p < 0.001). We also evaluated our method in the dataset provided for the 2014 MICCAI Pathology Classification Challenge, in which our method, trained and tested using 5-fold cross validation, produced a classification accuracy of 100% (p < 0.001). Our method showed high stability and robustness to parameter variation, with accuracy varying between 95.5% and 100% when evaluated for a wide range of parameters. Our approach may be useful to automatically differentiate between the two cancer subtypes. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. System and method for generating motion corrected tomographic images

    DOEpatents

    Gleason, Shaun S [Knoxville, TN; Goddard, Jr., James S.

    2012-05-01

    A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

  2. An Integrated On-Line Transfer Credit Evaluation System-Admissions through Graduation Audit.

    ERIC Educational Resources Information Center

    Schuman, Chester D.

    This document discusses a computerized transfer evaluation system designed by Pennsylvania College of Technology, a comprehensive two-year institution with an enrollment of over 4,800 students. It is noted that the Admissions Office processes approximately 500 transfer applications for a fall semester, as well as a large number of evaluations for…

  3. Optical tomographic memories: algorithms for the efficient information readout

    NASA Astrophysics Data System (ADS)

    Pantelic, Dejan V.

    1990-07-01

    Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different

  4. Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

    PubMed

    Crotty, Dominic J; Brady, Samuel L; Jackson, D'Vone C; Toncheva, Greta I; Anderson, Colin E; Yoshizumi, Terry T; Tornai, Martin P

    2011-06-01

    A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.

  5. Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam

    PubMed Central

    Crotty, Dominic J.; Brady, Samuel L.; Jackson, D’Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.

    2011-01-01

    Purpose: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Methods: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Results: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Conclusions: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging. PMID:21815398

  6. Identification of drug interactions in hospitals--computerized screening vs. bedside recording.

    PubMed

    Blix, H S; Viktil, K K; Moger, T A; Reikvam, A

    2008-04-01

    Managing drug interactions in hospitalized patients is important and challenging. The objective of the study was to compare two methods for identification of drug interactions (DDIs)--computerized screening and prospective bedside recording--with regard to capability of identifying DDIs. Patient characteristics were recorded for patients admitted to five hospitals. By bedside evaluation drug-related problems, including DDIs, were prospectively recorded by pharmacists and discussed in multidisciplinary teams. A computer screening programme was used to identify DDIs retrospectively--dividing DDIs into four classes: A, avoid; B, avoid/take precautions; C, take precautions; D, no action needed. Among 827 patients, computer screening identified DDIs in 544 patients (66%); 351 had DDIs introduced in hospital. The 1513 computer-identified DDIs had the following distribution: type A 78; type B 915; type C 38; type D 482. By bedside evaluation, 99 DDIs were identified in 73 patients (9%). The proportions of computer recorded DDIs which were also identified at the bedside were: 5%, 8%, 8%, 2% DDIs of types A, B, C and D respectively. In 10 patients, DDIs not registered by computer screening were identified by bedside evaluation. The drugs most frequently involved in DDIs, identified by computerized screening were acetylsalicylic acid, warfarin, furosemide and digitoxin compared with warfarin, simvastatin, theophylline and carbamazepine, by bedside evaluation. Despite an active prospective bedside search for DDIs, this approach identified less than one in 10 of the DDIs recorded by computer screening, including those regarded as hazardous. However, computer screening overestimates considerably when the objective is to identify clinically relevant DDIs.

  7. Efficacy of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for the quantitative evaluation of the structural integrity of superficial digital flexor tendons in horses.

    PubMed

    van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R

    2001-07-01

    To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.

  8. Management System for EMR Work Study Program.

    ERIC Educational Resources Information Center

    Columbia County Board of Public Instruction, Lake City, FL. Exceptional Child Education Dept.

    A computerized information management system involving the specification of objectives, the coding of teacher evaluations of students, and a variety of possible outputs has been used in a work study program for educable mentally retarded adolescents. Instructional objectives are specified and coded by number and category. Evaluation is by means of…

  9. VAMP: A computer program for calculating volume, area, and mass properties of aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Norton, P. J.; Glatt, C. R.

    1974-01-01

    A computerized procedure developed for analyzing aerospace vehicles evaluates the properties of elemental surface areas with specified thickness by accumulating and combining them with arbitrarily specified mass elements to form a complete evaluation. Picture-like images of the geometric description are capable of being generated.

  10. Using Bayesian Networks to Improve Knowledge Assessment

    ERIC Educational Resources Information Center

    Millan, Eva; Descalco, Luis; Castillo, Gladys; Oliveira, Paula; Diogo, Sandra

    2013-01-01

    In this paper, we describe the integration and evaluation of an existing generic Bayesian student model (GBSM) into an existing computerized testing system within the Mathematics Education Project (PmatE--Projecto Matematica Ensino) of the University of Aveiro. This generic Bayesian student model had been previously evaluated with simulated…

  11. Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou Chuan; Chan, H.-P.; Sahiner, Berkman

    2007-12-15

    The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix atmore » multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.« less

  12. Evaluation of retroreflectometers.

    DOT National Transportation Integrated Search

    2002-08-01

    This project performed field-testing and analysis of two pavement marking retroreflectometers: the Laserlux and the : LTL2000. The Laserlux is a vehiclemounted device that takes readings at driving speed and produces : computerized output. The LTL...

  13. Pseudo-shading technique in the two-dimensional domain: a post-processing algorithm for enhancing the Z-buffer of a three-dimensional binary image.

    PubMed

    Tan, A C; Richards, R

    1989-01-01

    Three-dimensional (3D) medical graphics is becoming popular in clinical use on tomographic scanners. Research work in 3D reconstructive display of computerized tomography (CT) and magnetic resonance imaging (MRI) scans on conventional computers has produced many so-called pseudo-3D images. The quality of these images depends on the rendering algorithm, the coarseness of the digitized object, the number of grey levels and the image screen resolution. CT and MRI data are fundamentally voxel based and they produce images that are coarse because of the resolution of the data acquisition system. 3D images produced by the Z-buffer depth shading technique suffer loss of detail when complex objects with fine textural detail need to be displayed. Attempts have been made to improve the display of voxel objects, and existing techniques have shown the improvement possible using these post-processing algorithms. The improved rendering technique works on the Z-buffer image to generate a shaded image using a single light source in any direction. The effectiveness of the technique in generating a shaded image has been shown to be a useful means of presenting 3D information for clinical use.

  14. Electrical properties of rat muscle after sciatic nerve injury: Impact on surface impedance measurements assessed via finite element analysis

    NASA Astrophysics Data System (ADS)

    Ahad, M. A.; Rutkove, S. B.

    2010-04-01

    Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.

  15. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  16. Comparison study on the feasibility of photoacoustic power spectrum analysis in osteoporosis detection

    NASA Astrophysics Data System (ADS)

    He, Weizhen; Zhu, Yunhao; Feng, Ting; Wang, Huaideng; Yuan, Jie; Xu, Guan; Wang, Xueding; Carson, Paul

    2017-03-01

    Osteoporosis is a progressive bone disease which is characterized by a decrease in the bone mass and deterioration in bone micro-architecture. In theory, photoacoustic (PA) imaging analysis has potential to obtain the characteristics of the bone effectively. Previous study demonstrated that photoacoustic spectral analysis (PASA) method with the qualified parameter slope could provide an objective assessment of bone microstructure and deterioration. In this study, we tried to compare PASA method with the traditional quantitative ultrasound (QUS) method in osteoporosis assessment. Numerical simulations of both PA and ultrasound (US) signal are performed on computerized tomographic (CT) images of trabecular bone with different bone mineral densities (BMDs). Ex vivo experiments were conducted on porcine femur bone model of different BMDs. We compared the quantified parameter slope and the broadband ultrasound attenuation (BUA) coefficient from the PASA and QUS among different bone models, respectively. Both the simulation and ex vivo experiment results show that bone with low BMD has a higher slope value and lower BUA value. Our result demonstrated that the PASA method has the same efficacy with QUS in bone assessment, considering PA is a non-ionizing, non-invasive technique, PASA method holds potential for clinical diagnosis in osteoporosis and other bone diseases.

  17. Creation of virtual patients from CT images of cadavers to enhance integration of clinical and basic science student learning in anatomy.

    PubMed

    Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F

    2009-08-01

    The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.

  18. Utility of cervical spinal and abdominal computed tomography in diagnosing occult pneumothorax in patients with blunt trauma: Computed tomographic imaging protocol matters.

    PubMed

    Akoglu, Haldun; Akoglu, Ebru Unal; Evman, Serdar; Akoglu, Tayfun; Denizbasi, Arzu; Guneysel, Ozlem; Onur, Ozge; Onur, Ender

    2012-10-01

    Small pneumothoraces (PXs), which are not initially recognized with a chest x-ray film and diagnosed by a thoracic computed tomography (CT), are described as occult PX (OCPX). The objective of this study was to evaluate cervival spine (C-spine) and abdominal CT (ACT) for diagnosing OCPX and overt PX (OVPX). All patients with blunt trauma who presented consecutively to the emergency department during a 26-months period were included. Among all the chest CTs (CCTs) (6,155 patients) conducted during that period, 254 scans were confirmed to have a true PX. The findings in their C-spine CT and ACT were compared with the findings in CCTs. Among these patients, 254 had a diagnosis of PX confirmed with CCT. OCPXs were identified on the chest computed tomographic scan of 128 patients (70.3%), whereas OVPXs were evident in 54 patients (29.7%). Computed tomographic imaging of the C-spine was performed in 74% of patients with OCPX and 66.7% of patients with OVPX trauma. Only 45 (35.2%) cases of OCPX and 42 (77.8%) cases of OVPX were detected by C-spine CT. ACT was performed in almost all patients, and 121 (95.3%) of 127 of these correctly identified an existing OCPX. Sensitivity of C-spine CT and ACT was 35.1% and 96.5%, respectively; specificity was 100% and 100%, respectively. Almost all OCPXs, regardless of intrathoracic location, could be detected by ACT or by combining C-spine and abdominal computed tomographic screening for patients. If the junction of the first and second vertebra is used as the caudad extent, C-spine CT does not have sufficient power to diagnose more than a third of the cases. Diagnostic study, level III.

  19. Influence of using a single facial vein as outflow in full-face transplantation: A three-dimensional computed tomographic study.

    PubMed

    Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai

    2015-10-01

    The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. How to Train an Injured Brain? A Pilot Feasibility Study of Home-Based Computerized Cognitive Training.

    PubMed

    Verhelst, Helena; Vander Linden, Catharine; Vingerhoets, Guy; Caeyenberghs, Karen

    2017-02-01

    Computerized cognitive training programs have previously shown to be effective in improving cognitive abilities in patients suffering from traumatic brain injury (TBI). These studies often focused on a single cognitive function or required expensive hardware, making it difficult to be used in a home-based environment. This pilot feasibility study aimed to evaluate the feasibility of a newly developed, home-based, computerized cognitive training program for adolescents who suffered from TBI. Additionally, feasibility of study design, procedures, and measurements were examined. Case series, longitudinal, pilot, feasibility intervention study with one baseline and two follow-up assessments. Nine feasibility outcome measures and criteria for success were defined, including accessibility, training motivation/user experience, technical smoothness, training compliance, participation willingness, participation rates, loss to follow-up, assessment timescale, and assessment procedures. Five adolescent patients (four boys, mean age = 16 years 7 months, standard deviation = 9 months) with moderate to severe TBI in the chronic stage were recruited and received 8 weeks of cognitive training with BrainGames. Effect sizes (Cohen's d) were calculated to determine possible training-related effects. The new cognitive training intervention, BrainGames, and study design and procedures proved to be feasible; all nine feasibility outcome criteria were met during this pilot feasibility study. Estimates of effect sizes showed small to very large effects on cognitive measures and questionnaires, which were retained after 6 months. Our pilot study shows that a longitudinal intervention study comprising our novel, computerized cognitive training program and two follow-up assessments is feasible in adolescents suffering from TBI in the chronic stage. Future studies with larger sample sizes will evaluate training-related effects on cognitive functions and underlying brain structures.

  1. COMPUTERIZED EXPERT SYSTEM FOR EVALUATION OF AUTOMATED VISUAL FIELDS FROM THE ISCHEMIC OPTIC NEUROPATHY DECOMPRESSION TRIAL: METHODS, BASELINE FIELDS, AND SIX-MONTH LONGITUDINAL FOLLOW-UP

    PubMed Central

    Feldon, Steven E

    2004-01-01

    ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764

  2. Computerized Agility Training Improves Change-of-Direction and Balance Performance Independently of Footwear in Young Adults.

    PubMed

    Paquette, Max R; Schilling, Brian K; Bravo, Joshua D; Peel, Shelby A; Li, Yuhua; Townsend, Robert J

    2017-03-01

    Understanding the effects of training in different footwear on sporting performance would be useful to coaches and athletes. This study compared the effects of computerized agility training using 3 types of footwear on change-of-direction and balance performance in young adults. Thirty recreationally active young adults (M age  = 22.8 ± 3.1 years; M height  = 1.71 ± 0.7 m; M bodymass  = 73.4 ± 10.3 kg) were randomly assigned to a 6-week computerized agility training intervention in 1 of 3 footwear groups (n = 10/group): barefoot, minimal footwear, or traditional shoes. Participants had no previous barefoot or minimal-footwear training experience. Dependent variables included change-of-direction test time to completion, Star Excursion Balance Test, and single-leg stability evaluation. Testing was performed at the start of the training program, after 2 weeks, after 4 weeks, and at the end of the training program. No group or time interactions were found for any of the dependent variables. Time main effects were observed for the performance measures of change of direction, Star Excursion, and single-leg-with-eyes-open stability evaluation. Participants improved in all 3 tests as early as 2 weeks into the intervention, with improvements continuing through the entire 6-week intervention. The lack of interaction and footwear effects suggests that agility and balance improvements during foot agility training are independent of footwear in a recreationally active young-adult population. Computerized agility training improves change-of-direction and balance performance within 2 weeks of training implementation. Future studies should consider footwear training effects in different populations, including frail older adults and athletes.

  3. Non-contact continuous-wave diffuse optical tomographic system to capture vascular dynamics in the foot

    NASA Astrophysics Data System (ADS)

    Hoi, Jennifer W.; Kim, Hyun K.; Khalil, Michael A.; Fong, Christopher J.; Marone, Alessandro; Shrikhande, Gautam; Hielscher, Andreas H.

    2015-03-01

    Dynamic optical tomographic imaging has shown promise in diagnosing and monitoring peripheral arterial disease (PAD), which affects 8 to 12 million in the United States. PAD is the narrowing of the arteries that supply blood to the lower extremities. Prolonged reduced blood flow to the foot leads to ulcers and gangrene, which makes placement of optical fibers for contact-based optical tomography systems difficult and cumbersome. Since many diabetic PAD patients have foot wounds, a non-contact interface is highly desirable. We present a novel non-contact dynamic continuous-wave optical tomographic imaging system that images the vasculature in the foot for evaluating PAD. The system images at up to 1Hz by delivering 2 wavelengths of light to the top of the foot at up to 20 source positions through collimated source fibers. Transmitted light is collected with an electron multiplying charge couple device (EMCCD) camera. We demonstrate that the system can resolve absorbers at various locations in a phantom study and show the system's first clinical 3D images of total hemoglobin changes in the foot during venous occlusion at the thigh. Our initial results indicate that this system is effective in capturing the vascular dynamics within the foot and can be used to diagnose and monitor treatment of PAD in diabetic patients.

  4. Computer-aided interpretation approach for optical tomographic images

    NASA Astrophysics Data System (ADS)

    Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.

    2010-11-01

    A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.

  5. Computerized Writing and Reading Instruction for Students in Grades 4 to 9 With Specific Learning Disabilities Affecting Written Language

    PubMed Central

    Tanimoto, Steven; Thompson, Rob; Berninger, Virginia W.; Nagy, William; Abbott, Robert D.

    2015-01-01

    Computer scientists and educational researchers evaluated effectiveness of computerized instruction tailored to evidence-based impairments in specific learning disabilities (SLDs) in students in grades 4 to 9 with persisting SLDs despite prior extra help. Following comprehensive, evidence-based differential diagnosis for dysgraphia (impaired handwriting), dyslexia (impaired word reading and spelling), and oral and written language learning disability (OWL LD), students completed 18 sessions of computerized instruction over about 3 months. The 11 students taught letter formation with sequential, numbered, colored arrow cues with full contours who wrote letters on lines added to iPAD screen showed more and stronger treatment effects than the 21 students taught using only visual motion cues for letter formation who wrote on an unlined computer monitor. Teaching to all levels of language in multiple functional language systems (by ear, eye, mouth, and hand) close in time resulted in significant gains in reading and writing skills for the group and in diagnosed SLD hallmark impairments for individuals; also, performance on computerized learning activities correlated with treatment gains. Results are discussed in reference to need for both accommodations and explicit instruction for persisting SLDs and the potential for computers to teach handwriting, morphophonemic orthographies, comprehension, and composition. PMID:26858470

  6. Computerized Doppler Tomography and Spectrum Analysis of Carotid Artery Flow

    PubMed Central

    Morton, Paul; Goldman, Dave; Nichols, W. Kirt

    1981-01-01

    Contrast angiography remains the definitive study in the evaluation of atherosclerotic occlusive vascular disease. However, a safer technique for serial screening of symptomatic patients and for routine follow up is necessary. Computerized pulsed Doppler ultrasonic arteriography is a noninvasive technique developed by Miles6 for imaging lateral, antero-posterior and transverse sections of the carotid artery. We [ill] this system with new software and hardware to analyze the three-dimensional blood flow data. The system now provides information about the location of the occlusive process in the artery and a semi-quantitative evaluation of the degree of obstruction. In addition, we interfaced a digital signal analyzer to the system which permits spectrum analysis of the pulsed Doppler signal. This addition has allowed us to identify lesions which are not yet hemodynamically significant. ImagesFig. 2bFig. 2c

  7. Uroradiographic manifestations of Burkitt's lymphoma in children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernbach, S.K.; Glass, R.B.

    1986-05-01

    The radiological studies of 18 children with biopsy proved Burkitt's lymphoma were analyzed retrospectively. Before therapy the genitourinary tract was evaluated in 15 children by excretory urography, sonography, computerized tomography and/or gallium citrate scintigraphy. Genitourinary abnormalities were detected in 9 children. Changes due to tumor included renal or ureteral displacement in 4 children, hydronephrosis in 3 and intraparenchymal masses in 4. Extrinsic compression of the bladder causing no compromise of function was seen in only 2 children. Gonadal involvement occurred in 2 boys and 1 girl. The modality of choice for evaluating the genitourinary tract in patients with Burkitt's lymphomamore » has been excretory urography. Since ultrasound and computerized tomography provide more direct information about tumor deposits within the kidney and retroperitoneum, either should be performed in this population before initiation of chemotherapy.« less

  8. Assessment of text documentation accompanying uncoded diagnoses in computerized health insurance claims in Japan.

    PubMed

    Tanihara, Shinichi

    2015-01-01

    Uncoded diagnoses in health insurance claims (HICs) may introduce bias into Japanese health statistics dependent on computerized HICs. This study's aim was to identify the causes and characteristics of uncoded diagnoses. Uncoded diagnoses from computerized HICs (outpatient, inpatient, and the diagnosis procedure-combination per-diem payment system [DPC/PDPS]) submitted to the National Health Insurance Organization of Kumamoto Prefecture in May 2010 were analyzed. The text documentation accompanying the uncoded diagnoses was used to classify diagnoses in accordance with the International Classification of Diseases-10 (ICD-10). The text documentation was also classified into four categories using the standard descriptions of diagnoses defined in the master files of the computerized HIC system: 1) standard descriptions of diagnoses, 2) standard descriptions with a modifier, 3) non-standard descriptions of diagnoses, and 4) unclassifiable text documentation. Using these classifications, the proportions of uncoded diagnoses by ICD-10 disease category were calculated. Of the uncoded diagnoses analyzed (n = 363 753), non-standard descriptions of diagnoses for outpatient, inpatient, and DPC/PDPS HICs comprised 12.1%, 14.6%, and 1.0% of uncoded diagnoses, respectively. The proportion of uncoded diagnoses with standard descriptions with a modifier for Diseases of the eye and adnexa was significantly higher than the overall proportion of uncoded diagnoses among every HIC type. The pattern of uncoded diagnoses differed by HIC type and disease category. Evaluating the proportion of uncoded diagnoses in all medical facilities and developing effective coding methods for diagnoses with modifiers, prefixes, and suffixes should reduce number of uncoded diagnoses in computerized HICs and improve the quality of HIC databases.

  9. Histological and computed tomographic evaluation of a parasitic conjoined twin in hybrid catfish (Ictalurus punctatus [rafinesque] X Ictalurus furcatus [lesueur])

    USDA-ARS?s Scientific Manuscript database

    There is growing use of hybrid catfish (Ictalurus punctatus ' X Ictalurus furcatus ') in commercial aquaculture to utilize hybrid vigour to improve production A conjoined twin specimen found during the course of production studies by the United States Department of Agriculture Catfish Genetic Resear...

  10. Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects.

    PubMed

    Groth, Michael J; Bhatnagar, Aparna; Clearihue, William J; Goldberg, Robert A; Douglas, Raymond S

    2006-01-01

    To report the long-term efficacy of custom polymethyl methacrylate implants using high-resolution computed tomographic modeling in the reconstruction of complex orbitofacial defects secondary to trauma. Nine patients with complex orbitofacial bone defects after trauma were evaluated for this retrospective, nonrandomized, noncomparative study. All the patients underwent reconstruction using custom, heat-cured polymethyl methacrylate implants. Patients were followed up postoperatively and evaluated for complications. Nine consecutive patients (5 men and 4 women) aged 28 to 63 years who underwent surgical reconstruction using prefabricated, heat-cured polymethyl methacrylate implants were included in the study. The interval between injury and presentation ranged from 1 month to 40 years. There were no significant complications, including infection, extrusion, or displacement of the implant. In all of the patients, wound healing was uneventful, with antibiotic drugs administered perioperatively. Mean follow-up was 4.3 years from the first visit (range, 6 months to 10 years). Computed tomographic biomodeled, prefabricated, heat-cured polymethyl methacrylate implants are well tolerated in the long term. Their advantages include customized design, long-term biocompatibility, and excellent aesthetic results.

  11. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    PubMed

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  12. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery

    PubMed Central

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-01-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function. PMID:23460599

  13. New developments in multimodal clinical multiphoton tomography

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2011-03-01

    80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.

  14. Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelines

    PubMed Central

    Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C

    2014-01-01

    Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706

  15. Evaluation of Hand Written and Computerized Out-Patient Prescriptions in Urban Part of Central Gujarat.

    PubMed

    Joshi, Anuradha; Buch, Jatin; Kothari, Nitin; Shah, Nishal

    2016-06-01

    Prescription order is an important therapeutic transaction between physician and patient. A good quality prescription is an extremely important factor for minimizing errors in dispensing medication and it should be adherent to guidelines for prescription writing for benefit of the patient. To evaluate frequency and type of prescription errors in outpatient prescriptions and find whether prescription writing abides with WHO standards of prescription writing. A cross-sectional observational study was conducted at Anand city. Allopathic private practitioners practising at Anand city of different specialities were included in study. Collection of prescriptions was started a month after the consent to minimize bias in prescription writing. The prescriptions were collected from local pharmacy stores of Anand city over a period of six months. Prescriptions were analysed for errors in standard information, according to WHO guide to good prescribing. Descriptive analysis was performed to estimate frequency of errors, data were expressed as numbers and percentage. Total 749 (549 handwritten and 200 computerised) prescriptions were collected. Abundant omission errors were identified in handwritten prescriptions e.g., OPD number was mentioned in 6.19%, patient's age was mentioned in 25.50%, gender in 17.30%, address in 9.29% and weight of patient mentioned in 11.29%, while in drug items only 2.97% drugs were prescribed by generic name. Route and Dosage form was mentioned in 77.35%-78.15%, dose mentioned in 47.25%, unit in 13.91%, regimens were mentioned in 72.93% while signa (direction for drug use) in 62.35%. Total 4384 errors out of 549 handwritten prescriptions and 501 errors out of 200 computerized prescriptions were found in clinicians and patient details. While in drug item details, total number of errors identified were 5015 and 621 in handwritten and computerized prescriptions respectively. As compared to handwritten prescriptions, computerized prescriptions appeared to be associated with relatively lower rates of error. Since out-patient prescription errors are abundant and often occur in handwritten prescriptions, prescribers need to adapt themselves to computerized prescription order entry in their daily practice.

  16. Radionuclide and Fluorescence Imaging of Clear Cell Renal Cell Carcinoma Using Dual Labeled Anti-Carbonic Anhydrase IX Antibody G250.

    PubMed

    Muselaers, Constantijn H J; Rijpkema, Mark; Bos, Desirée L; Langenhuijsen, Johan F; Oyen, Wim J G; Mulders, Peter F A; Oosterwijk, Egbert; Boerman, Otto C

    2015-08-01

    Tumor targeted optical imaging using antibodies labeled with near infrared fluorophores is a sensitive imaging modality that might be used during surgery to assure complete removal of malignant tissue. We evaluated the feasibility of dual modality imaging and image guided surgery with the dual labeled anti-carbonic anhydrase IX antibody preparation (111)In-DTPA-G250-IRDye800CW in mice with intraperitoneal clear cell renal cell carcinoma. BALB/c nu/nu mice with intraperitoneal SK-RC-52 lesions received 10 μg DTPA-G250-IRDye800CW labeled with 15 MBq (111)In or 10 μg of the dual labeled irrelevant control antibody NUH-82 (20 mice each). To evaluate when tumors could be detected, 4 mice per group were imaged weekly during 5 weeks with single photon emission computerized tomography/computerized tomography and the fluorescence imaging followed by ex vivo biodistribution studies. As early as 1 week after tumor cell inoculation single photon emission computerized tomography and fluorescence images showed clear delineation of intraperitoneal clear cell renal cell carcinoma with good concordance between single photon emission computerized tomography/computerized tomography and fluorescence images. The high and specific accumulation of the dual labeled antibody conjugate in tumors was confirmed in the biodistribution studies. Maximum tumor uptake was observed 1 week after inoculation (mean ± SD 58.5% ± 18.7% vs 5.6% ± 2.3% injected dose per gm for DTPA-G250-IRDye800CW vs NUH-82, respectively). High tumor uptake was also observed at other time points. This study demonstrates the feasibility of dual modality imaging with dual labeled antibody (111)In-DTPA-G250-IRDye800CW in a clear cell renal cell carcinoma model. Results indicate that preoperative and intraoperative detection of carbonic anhydrase IX expressing tumors, positive resection margins and metastasis might be feasible with this approach. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Evaluation of Hand Written and Computerized Out-Patient Prescriptions in Urban Part of Central Gujarat

    PubMed Central

    Buch, Jatin; Kothari, Nitin; Shah, Nishal

    2016-01-01

    Introduction Prescription order is an important therapeutic transaction between physician and patient. A good quality prescription is an extremely important factor for minimizing errors in dispensing medication and it should be adherent to guidelines for prescription writing for benefit of the patient. Aim To evaluate frequency and type of prescription errors in outpatient prescriptions and find whether prescription writing abides with WHO standards of prescription writing. Materials and Methods A cross-sectional observational study was conducted at Anand city. Allopathic private practitioners practising at Anand city of different specialities were included in study. Collection of prescriptions was started a month after the consent to minimize bias in prescription writing. The prescriptions were collected from local pharmacy stores of Anand city over a period of six months. Prescriptions were analysed for errors in standard information, according to WHO guide to good prescribing. Statistical Analysis Descriptive analysis was performed to estimate frequency of errors, data were expressed as numbers and percentage. Results Total 749 (549 handwritten and 200 computerised) prescriptions were collected. Abundant omission errors were identified in handwritten prescriptions e.g., OPD number was mentioned in 6.19%, patient’s age was mentioned in 25.50%, gender in 17.30%, address in 9.29% and weight of patient mentioned in 11.29%, while in drug items only 2.97% drugs were prescribed by generic name. Route and Dosage form was mentioned in 77.35%-78.15%, dose mentioned in 47.25%, unit in 13.91%, regimens were mentioned in 72.93% while signa (direction for drug use) in 62.35%. Total 4384 errors out of 549 handwritten prescriptions and 501 errors out of 200 computerized prescriptions were found in clinicians and patient details. While in drug item details, total number of errors identified were 5015 and 621 in handwritten and computerized prescriptions respectively. Conclusion As compared to handwritten prescriptions, computerized prescriptions appeared to be associated with relatively lower rates of error. Since out-patient prescription errors are abundant and often occur in handwritten prescriptions, prescribers need to adapt themselves to computerized prescription order entry in their daily practice. PMID:27504305

  18. Computerizing medical records in Japan.

    PubMed

    Yasunaga, Hideo; Imamura, Tomoaki; Yamaki, Shintaro; Endo, Hiroyoshi

    2008-10-01

    The present study reports the current status of computerizing medical records in Japan. In 2001, the Ministry of Health, Labour and Welfare formulated the Grand Design for the Development of Information Systems in the Healthcare and Medical Fields. The Grand Design stated a numerical target for "spreading the use of electronic medical records (EMR) in at least 60% of Japan's hospitals with 400 or more beds by 2006." The objective of this study was to examine the extent to which EMR and order entry systems (OES) have been adopted as of February 2007 and to evaluate the Japanese government's policy regarding the computerization of medical records. We conducted a postal survey targeting medical institutions throughout Japan. In February 2007, we mailed self-administered questionnaires to all 1574 hospitals with 300 or more beds, and to a random selection of 1000 hospitals with less than 300 beds in addition to 4000 clinics. Responses were received from 812 (51.6%), 504 (50.5%), and 1769 (44.8%), respectively. We asked questions concerning: (i) the extent to which EMR and OES had been introduced; (ii) the reasons why certain institutions had not introduced EMR and (iii) the subjective evaluation of the efficacy and cost-effectiveness of EMR. The percentage of institutions that had introduced EMR as of February 2007 was 10.0% for hospitals and 10.1% for clinics. Even the percentage for hospitals with 400 or more beds was just 31.2%, illustrating that the government's target had not been reached. The most common reason given for not introducing EMR was: "The cost is high" which was observed in 82.0% of hospitals. It was considered that the introduction of EMR could improve 'inter-hospital networks', and 'time efficiency for physicians' by around 45% and 25% of hospitals, respectively. Healthcare information computerization in Japan is behind schedule because the introductory costs are high. For the computerization of healthcare information to be further promoted, prices of EMR systems should be lowered to a level which individual hospitals can afford. Furthermore, the communication between EMR systems should be further standardized to secure functional and semantic interoperability in Japan.

  19. Computerized Virtual Reality Simulation in Preclinical Dentistry: Can a Computerized Simulator Replace the Conventional Phantom Heads and Human Instruction?

    PubMed

    Plessas, Anastasios

    2017-10-01

    In preclinical dental education, the acquisition of clinical, technical skills, and the transfer of these skills to the clinic are paramount. Phantom heads provide an efficient way to teach preclinical students dental procedures safely while increasing their dexterity skills considerably. Modern computerized phantom head training units incorporate features of virtual reality technology and the ability to offer concurrent augmented feedback. The aims of this review were to examine and evaluate the dental literature for evidence supporting their use and to discuss the role of augmented feedback versus the facilitator's instruction. Adjunctive training in these units seems to enhance student's learning and skill acquisition and reduce the required faculty supervision time. However, the virtual augmented feedback cannot be used as the sole method of feedback, and the facilitator's input is still critical. Well-powered longitudinal randomized trials exploring the impact of these units on student's clinical performance and issues of cost-effectiveness are warranted.

  20. Accounting Information Systems in Healthcare: A Review of the Literature.

    PubMed

    Hammour, Hadal; Househ, Mowafa; Razzak, Hira Abdul

    2017-01-01

    As information technology progresses in Saudi Arabia, the manual accounting systems have become graduallyinadequate for decision needs. Subsequently, private and public healthcare divisions in Saudi Arabia perceive Computerized accounting information system (CAIS) as a vehicle to safeguard efficient and effective flow of information during the analysis, processes, and recording of financial data. Efficient and effective flow of information improvesthe decision making of staff, thereby improving the capability of health care sectors to reduce cost of the medical services.In this paper, we define computerized accounting systems from the point of view of health informatics. Also, the challenges and benefits of supporting CAIS applications in hospitals of Saudi Arabia. With these elements, we conclude that CAIS in Saudi Arabia can serve as a valuable tool for evaluating and controlling the cost of medical services in healthcare sectors. Supplementary education on the significance of having systems of computerized accounting within hospitals for nurses, doctors, and accountants with other health care staff is warranted in future.

  1. Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method.

    PubMed

    Ceyhanli, Kadir T; Orucoglu, Hasan; Erdilek, Necdet; Turkun, Murat; Akdağ, Mustafa S

    2015-12-01

    The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage.

  2. Outcomes of the JNT 1955 Phase I Viability Study of Gamma Emission Tomography for Spent Fuel Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobsson-Svard, Staffan; Smith, Leon E.; White, Timothy

    The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup,more » under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.« less

  3. A description of STEMS-- the stand and tree evaluation and modeling system.

    Treesearch

    David M. Belcher; Margaret R. Holdaway; Gary J. Brand

    1982-01-01

    This paper describes STEMS (Stand and Tree Evaluation and Modeling System), the current computerized Lake State tree growth projection system. It presents the program structure, discusses the growth and mortality components, the management subsystem, and the regeneration subsystem. Some preliminary results of model testing are presented and an application is...

  4. Guide for the Establishment and Evaluation of Services for Selective Dissemination of Information.

    ERIC Educational Resources Information Center

    Poncelet, J.

    This guide describes the components of a selective dissemination of information (SDI) service which is designed to give developing countries access to international sources of bibliographic information and provides guidelines for the establishment and evaluation of this type of service. It defines the main features of a computerized documentation…

  5. MDCT for Computerized Volumetry of Pneumothoraces in Pediatric Patients

    PubMed Central

    Cai, Wenli; Lee, Edward Y.; Vij, Abhinav; Mahmood, Soran A.; Yoshida, Hiroyuki

    2010-01-01

    OBJECTIVE Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in MDCT images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. MATERIALS AND METHODS Fifty-eight consecutive pediatric patients (mean age 12±6 years) with pneumothorax who underwent MDCT for evaluation were collected retrospectively for this study. All cases were imaged by a 16- or 64-MDCT scanner with weight-based kilovoltage, low-dose tube current, 1.0 ~ 1.5 pitch, 0.6 ~ 5.0 mm slice thickness, and a B70f (sharp) or B31f (soft) reconstruction kernel. Sixty-three pneumothoraces ≥1 cc were visually identified in the left (n = 30) or/and right (n = 33) lungs. Each identified pneumothorax was contoured manually on an Amira workstation V4.1.1 (Mercury Computer Systems, Chelmsford, Massachusetts) by two radiologists in consensus. The computerized volumes of the pneumothoraces were determined by application of our CAV scheme. The accuracy of our automated CAV scheme was evaluated by comparison between computerized volumetry and manual volumetry, for the total volume of pneumothoraces in the left and right lungs. RESULTS The mean difference between the computerized volumetry and the manual volumetry for all 63 pneumothoraces ≥1 cc was 8.2%. For pneumothoraces ≥10 cc, ≥50 cc, and ≥200 cc, the mean differences were 7.7% (n=57), 7.3% (n=33), and 6.4% (n=13), respectively. The correlation coefficient was 0.99 between the computerized volume and the manual volume of pneumothoraces. Bland-Altman analysis showed that computerized volumetry has a mean difference of −5.1% compared to manual volumetry. For all pneumothoraces ≥10 cc, the mean differences for slice thickness ≤1.25 mm, =1.5 mm, and =5.0 mm were 6.1% (n=28), 3.5% (n=10), and 12.2% (n=19), respectively. For the two reconstruction kernels, B70f and B31f, the mean differences were 6.3% (n=42, B70f) and 11.7% (n=15, B31f), respectively. CONCLUSION Our automated CAV scheme provides an accurate measurement of pneumothorax volume in MDCT images of pediatric patients. For accurate volumetric quantification of pneumothorax in children in MDCT images by use of the automated CAV scheme, we recommended reconstruction parameters based on a slice thickness ≤1.5 mm and the reconstruction kernel B70f. PMID:21216160

  6. MDCT for computerized volumetry of pneumothoraces in pediatric patients.

    PubMed

    Cai, Wenli; Lee, Edward Y; Vij, Abhinav; Mahmood, Soran A; Yoshida, Hiroyuki

    2011-03-01

    Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in multidetector computed tomography (MDCT) images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. Fifty-eight consecutive pediatric patients (mean age 12 ± 6 years) with pneumothorax who underwent MDCT for evaluation were collected retrospectively for this study. All cases were imaged by a 16- or 64-MDCT scanner with weight-based kilovoltage, low-dose tube current, 1.0-1.5 pitch, 0.6-5.0 mm slice thickness, and a B70f (sharp) or B31f (soft) reconstruction kernel. Sixty-three pneumothoraces ≥1 mL were visually identified in the left (n = 30) and right (n = 33) lungs. Each identified pneumothorax was contoured manually on an Amira workstation V4.1.1 (Mercury Computer Systems, Chelmsford, MA) by two radiologists in consensus. The computerized volumes of the pneumothoraces were determined by application of our CAV scheme. The accuracy of our automated CAV scheme was evaluated by comparison between computerized volumetry and manual volumetry, for the total volume of pneumothoraces in the left and right lungs. The mean difference between the computerized volumetry and the manual volumetry for all 63 pneumothoraces ≥1 mL was 8.2%. For pneumothoraces ≥10 mL, ≥50 mL, and ≥200 mL, the mean differences were 7.7% (n = 57), 7.3% (n = 33), and 6.4% (n = 13), respectively. The correlation coefficient was 0.99 between the computerized volume and the manual volume of pneumothoraces. Bland-Altman analysis showed that computerized volumetry has a mean difference of -5.1% compared to manual volumetry. For all pneumothoraces ≥10 mL, the mean differences for slice thickness ≤1.25 mm, = 1.5 mm, and = 5.0 mm were 6.1% (n = 28), 3.5% (n = 10), and 12.2% (n = 19), respectively. For the two reconstruction kernels, B70f and B31f, the mean differences were 6.3% (n = 42, B70f) and 11.7% (n = 15, B31f), respectively. Our automated CAV scheme provides an accurate measurement of pneumothorax volume in MDCT images of pediatric patients. For accurate volumetric quantification of pneumothorax in children in MDCT images by use of the automated CAV scheme, we recommended reconstruction parameters based on a slice thickness ≤1.5 mm and the reconstruction kernel B70f. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  7. Computed tomographic features of apical infection of equine maxillary cheek teeth: a retrospective study of 49 horses.

    PubMed

    Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S

    2014-07-01

    Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.

  8. Lq -Lp optimization for multigrid fluorescence tomography of small animals using simplified spherical harmonics

    NASA Astrophysics Data System (ADS)

    Edjlali, Ehsan; Bérubé-Lauzière, Yves

    2018-01-01

    We present the first Lq -Lp optimization scheme for fluorescence tomographic imaging. This is then applied to small animal imaging. Fluorescence tomography is an ill-posed, and in full generality, a nonlinear problem that seeks to image the 3D concentration distribution of a fluorescent agent inside a biological tissue. Standard candidates for regularization to deal with the ill-posedness of the image reconstruction problem include L1 and L2 regularization. In this work, a general Lq -Lp regularization framework (Lq discrepancy function - Lp regularization term) is introduced for fluorescence tomographic imaging. A method to calculate the gradient for this general framework is developed which allows evaluating the performance of different cost functions/regularization schemes in solving the fluorescence tomographic problem. The simplified spherical harmonics approximation is used to accurately model light propagation inside the tissue. Furthermore, a multigrid mesh is utilized to decrease the dimension of the inverse problem and reduce the computational cost of the solution. The inverse problem is solved iteratively using an lm-BFGS quasi-Newton optimization method. The simulations are performed under different scenarios of noisy measurements. These are carried out on the Digimouse numerical mouse model with the kidney being the target organ. The evaluation of the reconstructed images is performed both qualitatively and quantitatively using several metrics including QR, RMSE, CNR, and TVE under rigorous conditions. The best reconstruction results under different scenarios are obtained with an L1.5 -L1 scheme with premature termination of the optimization process. This is in contrast to approaches commonly found in the literature relying on L2 -L2 schemes.

  9. An index of beam hardening artifact for two-dimensional cone-beam CT tomographic images: establishment and preliminary evaluation

    NASA Astrophysics Data System (ADS)

    Yuan, Fusong; Lv, Peijun; Yang, Huifang; Wang, Yong; Sun, Yuchun

    2015-07-01

    Objectives: Based on the pixel gray value measurements, establish a beam-hardening artifacts index of the cone-beam CT tomographic image, and preliminarily evaluate its applicability. Methods: The 5mm-diameter metal ball and resin ball were fixed on the light-cured resin base plate respectively, while four vitro molars were fixed above and below the ball, on the left and right respectively, which have 10mm distance with the metal ball. Then, cone beam CT was used to scan the fixed base plate twice. The same layer tomographic images were selected from the two data and imported into the Photoshop software. The circle boundary was built through the determination of the center and radius of the circle, according to the artifact-free images section. Grayscale measurement tools were used to measure the internal boundary gray value G0, gray value G1 and G2 of 1mm and 20mm artifacts outside the circular boundary, the length L1 of the arc with artifacts in the circular boundary, the circumference L2. Hardening artifacts index was set A = (G1 / G0) * 0.5 + (G2 / G1) * 0.4 + (L2 / L1) * 0.1. Then, the A values of metal and resin materials were calculated respectively. Results: The A value of cobalt-chromium alloy material is 1, and resin material is 0. Conclusion: The A value reflects comprehensively the three factors of hardening artifacts influencing normal oral tissue image sharpness of cone beam CT. The three factors include relative gray value, the decay rate and range of artifacts.

  10. Relationship of Hypertension to Coronary Atherosclerosis and Cardiac Events in Patients With Coronary Computed Tomographic Angiography.

    PubMed

    Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S

    2017-08-01

    Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.

  11. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars.

    PubMed

    Kurthukoti, Ameet J; Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto

    2015-01-01

    Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. To evaluate by computed tomography-the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207.

  12. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars

    PubMed Central

    Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto

    2015-01-01

    ABSTRACT Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. Aims: To evaluate by computed tomography—the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. Materials and methods: A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. Results: All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. Conclusion: The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207. PMID:26628855

  13. First results from the ionospheric tomography experiment using beacon TEC data obtained by means of a network along a longitude of 136°E over Japan

    NASA Astrophysics Data System (ADS)

    Thampi, Smitha V.; Yamamoto, Mamoru

    2010-03-01

    A chain of newly designed GNU (GNU is not UNIX) Radio Beacon Receivers (GRBR) has recently been established over Japan, primarily for tomographic imaging of the ionosphere over this region. Receivers installed at Shionomisaki (33.45°N, 135.8°E), Shigaraki (34.8°N, 136.1°E), and Fukui (36°N, 136°E) continuously track low earth orbiting satellites (LEOS), mainly OSCAR, Cosmos, and FORMOSAT-3/COSMIC, to obtain simultaneous total electron content (TEC) data from these three locations, which are then used for the tomographic reconstruction of ionospheric electron densities. This is the first GRBR network established for TEC observations, and the first beacon-based tomographic imaging in Japanese longitudes. The first tomographic images revealed the temporal evolution with all of the major features in the ionospheric electron density distribution over Japan. A comparison of the tomographically reconstructed electron densities with the ƒ o F 2 data from Kokubunji (35°N, 139°E) revealed that there was good agreement between the datasets. These first results show the potential of GRBR and its network for making continuous, unattended ionospheric TEC measurements and for tomographic imaging of the ionosphere.

  14. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

    PubMed

    Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2014-06-01

    This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Tracking the fate of interested regions of struts at different time points has not been investigated. Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. On the feasibility of tomographic-PIV with low pulse energy illumination in a lifted turbulent jet flame

    NASA Astrophysics Data System (ADS)

    Boxx, I.; Carter, C. D.; Meier, W.

    2014-08-01

    Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.

  16. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  17. Evaluation of roadway sites for queue management.

    DOT National Transportation Integrated Search

    1991-01-01

    This study addresses the problem of queueing on highway facilities, wherein a large number of computerized methods for the analysis of different queueing situations are available. A three-tier classification system of the methodologies was used with ...

  18. HRIS Vendor Selection.

    ERIC Educational Resources Information Center

    Moore, James C.

    1985-01-01

    Questions administrators need to answer when selecting or evaluating a computerized personnel and/or payroll information system cover the type of system, resources for purchasing and/or developing it, activities needed and used for, its use, and issues of responsibility. (MSE)

  19. Weigh-in-Motion systems evaluation : final report.

    DOT National Transportation Integrated Search

    1976-04-01

    This relatively short-term project was initiated in order to perfect installation, operation, and maintenance practices necessary for continued accurate and reliable operation of a computerized Weigh-in-Motion system which will be used to gather truc...

  20. Utilization of oleogels as a replacement for solid fat in aerated baked goods: Physicochemical, rheological, and tomographic characterization

    USDA-ARS?s Scientific Manuscript database

    Canola oil-carnauba wax oleogels were evaluated as a replacement for shortening in a baked cake system. The use of oleogels produced cake batters with a lower pseudoplastic property and also contributed to their viscous nature. The shortening replacement with oleogels at up to 50% was effective in m...

  1. Computerized symptom and quality-of-life assessment for patients with cancer part I: development and pilot testing.

    PubMed

    Berry, Donna L; Trigg, Lisa J; Lober, William B; Karras, Bryant T; Galligan, Mary L; Austin-Seymour, Mary; Martin, Stephanie

    2004-09-01

    To develop and test an innovative computerized symptom and quality-of-life (QOL) assessment for patients with cancer who are evaluated for and treated with radiation therapy. Descriptive, longitudinal prototype development and cross-sectional clinical data. Department of radiation oncology in an urban, academic medical center. 101 outpatients who were evaluated for radiation therapy, able to communicate in English (or through one of many interpreters available at the University of Washington), and competent to understand the study information and give informed consent. Six clinicians caring for the patients in the sample were enrolled. Iterative prototype development was conducted using a standing focus group of clinicians. The software was developed based on survey markup language and implemented in a wireless, Web-based format. Patient participants completed the computerized assessment prior to consultation with the radiation physician. Graphical output pages with flagged areas of symptom distress or troublesome QOL issues were made available to consulting physicians and nurses. Pain intensity, symptoms, QOL, and demographics. Computerized versions of a 0 to 10 Pain Intensity Numerical Scale (PINS), Symptom Distress Scale, and Short Form-8. Focus group recommendations included clinician priorities of brevity, flexibility, and simplicity for both input interface and output and that the assessment output contain color graphic display. Patient participants included 45 women and 56 men with a mean age of 52.7 years (SD = 13.8). Fewer than half of the participants (40%) reported using a computer on a regular basis (weekly or daily). Completion time averaged 7.8 minutes (SD = 3.7). Moderate to high levels of distress were reported more often for fatigue, pain, and emotional issues than for other symptoms or concerns. Computerized assessment of cancer symptoms and QOL is technically possible and feasible in an ambulatory cancer clinic. A wireless, Web-based system facilitates access to results and data entry and retrieval. The symptom and QOL profiles of these patients new to radiation therapy were comparable to other samples of outpatients with cancer. The ability to capture an easily interpreted illustration of a patients symptom and QOL experience in less than 10 minutes is a potentially useful adjunct to traditional face-to-face interviewing. Ultimately, electronic patient-generated data could produce automated red flags directed to the most appropriate clinicians (e.g., nurse, pain specialist, social worker, nutritionist) for further evaluation. Such system enhancement could greatly facilitate oncology nurses coordination role in caring for complex patients with cancer.

  2. Role of mantle dynamics in rebuilding the Tianshan Orogenic Belt in NW China: A seismic tomographic investigation

    NASA Astrophysics Data System (ADS)

    He, Chuansong; Santosh, M.

    2018-05-01

    The Tianshan orogenic belt, Junggar terrane and Altai terrane are located at the southwestern part of the Central Asian Orogenic Belt (CAOB). Here, we investigate the velocity structure beneath the Xinjiang region in NW China, which includes the Tarim terrane, Tianshan orogenic belt, Junggar terrane and Altai terrane with a view to evaluate the mantle dynamics based on teleseismic data recorded by 103 seismic stations. Our tomographic results show both high and low velocity perturbations beneath the Tianshan orogenic belt. We suggest that the high velocity perturbations beneath this orogenic belt might represent the northward subducted lithosphere of the Tarim Basin and the southward subducted lithosphere of the Junggar Basin. The low velocity structure beneath the Tianshan orogenic belt might represent asthenosphere upwelling that triggered the extensive magmatism which contributed to rebuilding of the Tianshan orogenic belt.

  3. A tomographic technique for aerodynamics at transonic speeds

    NASA Technical Reports Server (NTRS)

    Lee, G.

    1985-01-01

    Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

  4. System Performance Simulations of the RatCAP Awake Rat Brain Scanner

    NASA Astrophysics Data System (ADS)

    Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.

    2005-10-01

    The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.

  5. Finite-frequency wave propagation through outer rise fault zones and seismic measurements of upper mantle hydration

    USGS Publications Warehouse

    Miller, Nathaniel; Lizarralde, Daniel

    2016-01-01

    Effects of serpentine-filled fault zones on seismic wave propagation in the upper mantle at the outer rise of subduction zones are evaluated using acoustic wave propagation models. Modeled wave speeds depend on azimuth, with slowest speeds in the fault-normal direction. Propagation is fastest along faults, but, for fault widths on the order of the seismic wavelength, apparent wave speeds in this direction depend on frequency. For the 5–12 Hz Pn arrivals used in tomographic studies, joint-parallel wavefronts are slowed by joints. This delay can account for the slowing seen in tomographic images of the outer rise upper mantle. At the Middle America Trench, confining serpentine to fault zones, as opposed to a uniform distribution, reduces estimates of bulk upper mantle hydration from ~3.5 wt % to as low as 0.33 wt % H2O.

  6. 3D electron tomography of pretreated biomass informs atomic modeling of cellulose microfibrils.

    PubMed

    Ciesielski, Peter N; Matthews, James F; Tucker, Melvin P; Beckham, Gregg T; Crowley, Michael F; Himmel, Michael E; Donohoe, Bryon S

    2013-09-24

    Fundamental insights into the macromolecular architecture of plant cell walls will elucidate new structure-property relationships and facilitate optimization of catalytic processes that produce fuels and chemicals from biomass. Here we introduce computational methodology to extract nanoscale geometry of cellulose microfibrils within thermochemically treated biomass directly from electron tomographic data sets. We quantitatively compare the cell wall nanostructure in corn stover following two leading pretreatment strategies: dilute acid with iron sulfate co-catalyst and ammonia fiber expansion (AFEX). Computational analysis of the tomographic data is used to extract mathematical descriptions for longitudinal axes of cellulose microfibrils from which we calculate their nanoscale curvature. These nanostructural measurements are used to inform the construction of atomistic models that exhibit features of cellulose within real, process-relevant biomass. By computational evaluation of these atomic models, we propose relationships between the crystal structure of cellulose Iβ and the nanoscale geometry of cellulose microfibrils.

  7. Condylar repositioning using centric relation bite in bimaxillary surgery

    PubMed Central

    Lee, Chang-Youn; Jang, Chang-Su; Kim, Ju-Won; Kim, Jwa-Young

    2013-01-01

    Objective The purpose of this study was to evaluate displacement of the mandibular condyle after orthognathic surgery using a condylar-repositioning device. Methods The patient group comprised 20 adults who underwent bimaxillary surgery between August 2008 and July 2011. The degree of condylar displacement was measured by pre- and postoperative tomographic analysis using centric relation bite and a wire during surgery. A survey assessing temporomandibular joint (TMJ) sound, pain, and locking was performed. The 20 tomographs and surveys were analyzed using the Wilcoxon signed-rank test and McNemar's test, respectively. Results No significant changes were observed in the anterior, superior, or posterior joint space of the TMJ (p > 0.05). In addition, no significant change was observed in TMJ sound (p > 0.05). However, TMJ pain and locking both decreased significantly after surgery (p < 0.05). Conclusions Due to its simplicity, this method may be feasible and useful for repositioning condyles. PMID:23671832

  8. TOMOGRAPHIC MORPHOLOGICAL STUDY OF THE CRANIUM AND ITS CORRELATION WITH CRANIAL HALO USE IN ADULTS

    PubMed Central

    ALMEIDA, TIAGO FERREIRA DE; CHARAFEDDINE, HOMAR TOLEDO; ARAÚJO, FERNANDO FLORES DE; CRISTANTE, ALEXANDRE FOGAÇA; MARCON, RAPHAEL MARTUS; LETAIF, OLAVO BIRAGHI

    2017-01-01

    ABSTRACT Objective: To evaluate using tomographic study the thickness of the cranial board at the insertions points of the cranial halo pins in adults Methods: This is a retrospective, cross-sectional, descriptive analysis of Computed Tomography (CT) scans of adult patients' crania. The study included adults between 20 and 50 years without cranial abnormalities. We excluded any exam with cranial abnormalities Results: We analyzed 50 CT scans, including 27 men and 23 women, at the original insertion points and alternative points (1 and 2 cm above the frontal and parietal bones). The average values were 7.4333 mm in the frontal bone and 6.0290 mm in the parietal bone Conclusion: There was no statistically significant difference between the classical and alternative points, making room for alternative fixings and safer introduction of the pins, if necessary.Level of Evidence II, Retrospective Study. PMID:28642643

  9. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    PubMed

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings. Aerosp Med Hum Perform. 2017; 88(8):722-729.

  10. Impact of computerized pre-authorization of broad spectrum antibiotics in Pseudomonas aeruginosa at a children's hospital in Japan.

    PubMed

    Horikoshi, Yuho; Higuchi, Hiroshi; Suwa, Junichi; Isogai, Mihoko; Shoji, Takayo; Ito, Kenta

    2016-08-01

    The spread of antimicrobial-resistant organisms is a global concern. To stem this tide, an antimicrobial stewardship program at hospitals is essential to optimize the prescription of broad spectrum antibiotics. In this study we examined the impact of computerized pre-authorization for broad spectrum antibiotics for Pseudomonas aeruginosa at a children's hospital. An antimicrobial stewardship program at Tokyo Metropolitan Children's Medical Center was assessed between March 2010 and March 2015. A paper-based post-prescription audit was switched to computerized pre-authorization for broad antipseudomonal agents in October 2011. The prescriber was required to obtain approval from physicians in the pediatric infectious diseases division before prescribing restricted antimicrobial agents. Approved prescriptions were processed and logged electronically. We evaluated days of therapy per 1000 patient-days, the cost of antibiotics, and the susceptibility of P. aeruginosa to piperacillin, ceftazidime, cefepime, piperacillin/tazobactam, carbapenems, and ciprofloxacin. Also, the average length of admission and infection-related mortality at 30 days were compared pre- and post-intervention. Administration of carbapenems, piperacillin/tazobactam, and ceftazidime decreased significantly after the introduction of computerized pre-authorization. Antibiotic costs were reduced by JPY2.86 million (USD 26,000) annually. None of the antipseudomonal agents showed decreased sensitivity. The average length of admission was shorter in post-intervention. Infection-related mortality at 30 days showed no difference between the pre- and post-intervention periods. An antimicrobial stewardship program using computerized pre-authorization decreased the use and cost of broad spectrum antibiotics without significant difference in infection-related mortality at 30 days, although our study did not improve susceptibilities of P. aeruginosa. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. Canadian adaptation of the Newest Vital Sign©, a health literacy assessment tool.

    PubMed

    Mansfield, Elizabeth D; Wahba, Rana; Gillis, Doris E; Weiss, Barry D; L'Abbé, Mary

    2018-04-25

    The Newest Vital Sign© (NVS) was developed in the USA to measure patient health literacy in clinical settings. We adapted the NVS for use in Canada, in English and French, and created a computerized version. Our objective was to evaluate the reliability of the Canadian NVS as a self-administered computerized tool. We used a randomized crossover design with a washout period of 3-4 weeks to compare health literacy scores obtained using the computerized version with scores obtained using the standard interviewer-administered NVS. ANOVA models and McNemar's tests assessed differences in outcomes assessed with each version of the NVS and order effects of the testing. Participants were recruited from multicultural catchment areas in Ontario and Nova Scotia. English- and French-speaking adults aged 18 years or older. A total of 180 (81 %) of the 222 adults (112 English/110 French) initially recruited completed both the interviewer-NVS and computer-NVS. Scores for those who completed both assessments ranged from 0 to 6 with a mean of 3·63 (sd 2·11) for the computerized NVS and 3·41 (sd 2·21) for the interview-administered NVS. Few (n 18; seven English, eleven French) participants' health literacy assessments differed between the two versions. Overall, the computerized Canadian NVS performed as well as the interviewer-administered version for assessing health literacy levels of English- and French-speaking participants. This Canadian adaptation of the NVS provides Canadian researchers and public health practitioners with an easily administered health literacy assessment tool that can be used to address the needs of Canadians across health literacy levels and ultimately improve health outcomes.

  12. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... magnetic media, such as magnetic tapes or magnetic diskettes, containing the computerized information at.... The computerized magnetic media shall be prepared and delivered at the committee's expense and shall... Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal...

  13. SIRT-FILTER v1.0.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PELT, DANIEL

    2017-04-21

    Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).

  14. Metacognitive Prediction and Evaluation Skills and Mathematical Learning in Third-Grade Students

    ERIC Educational Resources Information Center

    Desoete, Annemie

    2009-01-01

    In a 2-year longitudinal study, 66 children were assessed in Grades 3 and 4 with a within-method-and-time design on metacognition (including the computerized Evaluation and Prediction Assessment [EPA2000]) and mathematics. Moreover, half of the children were trained in Grade 3 in the metacognitive skill of predicting their abilities in solving…

  15. Service Evaluation in a Special Library: Supporting Development Research at the Institute of Social Sciences Library, New Delhi.

    ERIC Educational Resources Information Center

    Ghosh, Sharmila

    2003-01-01

    Discusses the development of special libraries to meet demands of interdisciplinary information and describes the library at The Institute of Social Sciences, New Delhi (India) which establishes a synergy between research and information derived from research through a computerized information management system. Considers evaluation of special…

  16. An Evaluation of Results and Effectiveness of Job Banks: Volume I, Parts I and II.

    ERIC Educational Resources Information Center

    Ultrasystems, Inc., Irvine, CA.

    In order to assist the Manpower Administration of the U. S. Department of Labor in the planning, development, and expansion of over a hundred computerized "job banks," located in nearly every State, field interviews were conducted with job applicants, employers, Employment Service staff, and community agencies to evaluate the current…

  17. Mood Assessment via Animated Characters: A Novel Instrument to Evaluate Feelings in Young Children with Anxiety Disorders

    ERIC Educational Resources Information Center

    Manassis, Katharina; Mendlowitz, Sandra; Kreindler, David; Lumsden, Charles; Sharpe, Jason; Simon, Mark D.; Woolridge, Nicholas; Monga, Suneeta; Adler-Nevo, Gili

    2009-01-01

    We evaluated a novel, computerized feelings assessment instrument (MAAC) in 54 children with anxiety disorders and 35 nonanxious children ages 5 to 11. They rated their feelings relative to 16 feeling animations. Ratings of feelings, order of feeling selection, and correlations with standardized anxiety measures were examined. Positive emotions…

  18. [Computerized ranking test in three French universities: Staff experience and students' feedback].

    PubMed

    Roux, D; Meyer, G; Cymbalista, F; Bouaziz, J-D; Falgarone, G; Tesniere, A; Gervais, J; Cariou, A; Peffault de Latour, R; Marat, M; Moenaert, E; Guebli, T; Rodriguez, O; Lefort, A; Dreyfuss, D; Hajage, D; Ricard, J-D

    2016-03-01

    The year 2016 will be pivotal for the evaluation of French medical students with the introduction of the first computerized National Ranking Test (ECNi). The SIDES, online electronic system for medical student evaluation, was created for this purpose. All the universities have already organized faculty exams but few a joint computerized ranking test at several universities simultaneously. We report our experience on the organization of a mock ECNi by universities Paris Descartes, Paris Diderot and Paris 13. Docimological, administrative and technical working groups were created to organize this ECNi. Students in their fifth year of medical studies, who will be the first students to sit for the official ECNi in 2016, were invited to attend this mock exam that represented more than 50% of what will be proposed in 2016. A final electronic questionnaire allowed a docimological and organizational evaluation by students. An analysis of ratings and rankings and their distribution on a 1000-point scale were performed. Sixty-four percent of enrolled students (i.e., 654) attended the three half-day exams. No difference in total score and ranking between the three universities was observed. Students' feedback was extremely positive. Normalized over 1000 points, 99% of students were scored on 300 points only. Progressive clinical cases were the most discriminating test. The organization of a mock ECNi involving multiple universities was a docimological and technical success but required an important administrative, technical and teaching investment. Copyright © 2016 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  19. Surgical treatment of diaphyseal stress fractures of the fifth metatarsal in competitive athletes: long-term follow-up and computerized pedobarographic analysis.

    PubMed

    Pecina, Marko; Bojanic, Ivan; Smoljanovic, Tomislav; Ivkovic, Alan; Mirkovic, Maja; Jelic, Miroslav

    2011-01-01

    Proximal diaphyseal stress fractures of the fifth metatarsal are common in athletes. Conservative treatment has been shown to result in high rates of delayed union, nonunion, and refracture, so internal fixation has become the treatment of choice in competitive athletes. Twenty top-level athletes with diaphyseal stress fractures fixed with intramedullary malleolar screws were evaluated. Functional outcome was assessed by American Orthopaedic Foot and Ankle Society midfoot score. Static and dynamic maximum vertical force and peak plantar pressures were evaluated with a computerized pedobarograph. Mean follow-up from surgery to interview was 10.3 years (range, 3.5-19.0 years). Clinical healing was 95%, and there has been one refracture (5%). The mean time from surgery to return to sport was 9 weeks (range, 5-14 weeks). Twelve athletes (60%) returned to a higher level of training, 7 (35%) to the same level, and 1 (5%) to a lower level compared with the level of training before injury. Average American Orthopaedic Foot and Ankle Society midfoot score was 93.8 (range, 85-100). During the computerized pedobarographic evaluations, 18 patients (90%) presented with varus of the metatarsus and the midfoot and 2 (10%) presented with a normal plantigrade foot. Intramedullary malleolar screws can yield reliable and effective healing of fifth metatarsal stress fractures in athletes. Varus of the metatarsus and the midfoot were predisposing factors for stress fractures in this population of competitive athletes, and all were recommended to wear orthoses until their competitive careers were completed.

  20. Quantitation of mandibular ramus volume as a source of bone grafting.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p < 0.001). The bone volume measured 6 months post-sinus augmentation averaged 2.2 mL (SD 0.4 mL, range: 1.6-2.8 mL) with a mean loss of 0.3 mL in volume. The mandibular second molar area provided the thickest cortical graft. A cortical plate of 2.8 mm in average at combined second and third molar areas provided 2.5 mL particulated volume. The use of a design software program can improve surgical treatment planning prior to ramus bone grafting. The AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  1. Using a virtual reality temporal bone simulator to assess otolaryngology trainees.

    PubMed

    Zirkle, Molly; Roberson, David W; Leuwer, Rudolf; Dubrowski, Adam

    2007-02-01

    The objective of this study is to determine the feasibility of computerized evaluation of resident performance using hand motion analysis on a virtual reality temporal bone (VR TB) simulator. We hypothesized that both computerized analysis and expert ratings would discriminate the performance of novices from experienced trainees. We also hypothesized that performance on the virtual reality temporal bone simulator (VR TB) would differentiate based on previous drilling experience. The authors conducted a randomized, blind assessment study. Nineteen volunteers from the Otolaryngology-Head and Neck Surgery training program at the University of Toronto drilled both a cadaveric TB and a simulated VR TB. Expert reviewers were asked to assess operative readiness of the trainee based on a blind video review of their performance. Computerized hand motion analysis of each participant's performance was conducted. Expert raters were able to discriminate novices from experienced trainees (P < .05) on cadaveric temporal bones, and there was a trend toward discrimination on VR TB performance. Hand motion analysis showed that experienced trainees had better movement economy than novices (P < .05) on the VR TB. Performance, as measured by hand motion analysis on the VR TB simulator, reflects trainees' previous drilling experience. This study suggests that otolaryngology trainees could accomplish initial temporal bone training on a VR TB simulator, which can provide feedback to the trainee, and may reduce the need for constant faculty supervision and evaluation.

  2. Computerized tomography-guided sphenopalatine ganglion pulsed radiofrequency treatment in 16 patients with refractory cluster headaches: Twelve- to 30-month follow-up evaluations.

    PubMed

    Fang, Luo; Jingjing, Lu; Ying, Shen; Lan, Meng; Tao, Wang; Nan, Ji

    2016-02-01

    Sphenopalatine ganglion percutaneous radiofrequency thermocoagulation treatment can improve the symptoms of cluster headaches to some extent. However, as an ablation treatment, radiofrequency thermocoagulation treatment also has side effects. To preliminarily evaluate the efficacy and safety of a non-ablative computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion in patients with refractory cluster headaches. We included and analysed 16 consecutive cluster headache patients who failed to respond to conservative therapy from the Pain Management Center at the Beijing Tiantan Hospital between April 2012 and September 2013 treated with pulsed radiofrequency treatment of sphenopalatine ganglion. Eleven of 13 episodic cluster headaches patients and one of three chronic cluster headaches patient were completely relieved of the headache within an average of 6.3 ± 6.0 days following the treatment. Two episodic cluster headache patients and two chronic cluster headache patients showed no pain relief following the treatment. The mean follow-up time was 17.0 ± 5.5 months. All patients enrolled in this study showed no treatment-related side effects or complications. Our data show that patients with refractory episodic cluster headaches were quickly, effectively and safely relieved from the cluster period after computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion, suggesting that it may be a therapeutic option if conservative treatments fail. © International Headache Society 2015.

  3. A review of US anthropometric reference data (1971 2000) with comparisons to both stylized and tomographic anatomic models

    NASA Astrophysics Data System (ADS)

    Huh, C.; Bolch, W. E.

    2003-10-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ~5%), present-day 40-year-old males have an average total body mass that is ~16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males. Both Helga (27-year-old F) and Donna, however, provide good matches to average US sitting heights for adult females, while Golem and Otoko (male of unknown age) yield sitting heights that are slightly below US adult male averages. Finally, Helga is seen as the only GSF tomographic female model that yields a body mass index in line with her average US female counterpart at age 26. In terms of dose reconstruction activities, however, all current tomographic voxel models are valuable assets in attempting to cover the broad distribution of individual anthropometric parameters representative of the current US population. It is highly recommended that similar attempts to create a broad library of tomographic models be initiated in the United States and elsewhere to complement and extend the limited number of tomographic models presently available for these efforts.

  4. Integrating Prevention into Obstetrics/Gynecology.

    ERIC Educational Resources Information Center

    Carey, J. Christopher

    2000-01-01

    Discusses formats to teach preventive medicine in obstetrics and gynecology (including learning objectives, lectures/seminars, and rounds/office practice) and evaluation methods (oral examinations, computerized question banks, objective structured clinical examinations). Offers examples from specific programs at American medical schools, including…

  5. Critical factors influencing physicians' intention to use computerized clinical practice guidelines: an integrative model of activity theory and the technology acceptance model.

    PubMed

    Hsiao, Ju-Ling; Chen, Rai-Fu

    2016-01-16

    With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p < 0.001), organizational support (γ = 0.285, p < 0.001), perceived usefulness of computerized clinical practice guidelines (γ = 0.219, p < 0.05), and social influence (γ = 0.213, p < 0.05) were critical factors influencing physicians' intention to use computerized clinical practice guidelines, and these factors can explain 68.6 % of the variance in intention to use computerized clinical practice guidelines. This study confirmed that some subject (human) factors, environment (organization) factors, tool (technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.

  6. 39 CFR 501.15 - Computerized Meter Resetting System.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...

  7. Noninvasive imaging analysis of biological tissue associated with laser thermal injury.

    PubMed

    Chang, Cheng-Jen; Yu, De-Yi; Hsiao, Yen-Chang; Ho, Kuang-Hua

    2017-04-01

    The purpose of our study is to use a noninvasive tomographic imaging technique with high spatial resolution to characterize and monitor biological tissue responses associated with laser thermal injury. Optical doppler tomography (ODT) combines laser doppler flowmetry (LDF) with optical coherence tomography (OCT) to obtain high resolution tomographic velocity and structural images of static and moving constituents in highly scattering biological tissues. A SurgiLase XJ150 carbon dioxide (CO 2 ) laser using a continuous mode of 3 watts (W) was used to create first, second or third degree burns on anesthetized Sprague-Dawley rats. Additional parameters for laser thermal injury were assessed as well. The rationale for using ODT in the evaluation of laser thermal injury offers a means of constructing a high resolution tomographic image of the structure and perfusion of laser damaged skin. In the velocity images, the blood flow is coded at 1300 μm/s and 0 velocity, 1000 μm/s and 0 velocity, 700 μm/s and 0 velocity adjacent to the first, second, and third degree injuries, respectively. ODT produces exceptional spatial resolution while having a non-invasive way of measurement, therefore, ODT is an accurate measuring method for high-resolution fluid flow velocity and structural images for biological tissue with laser thermal injury. Copyright © 2017 Chang Gung University. Published by Elsevier B.V. All rights reserved.

  8. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    NASA Astrophysics Data System (ADS)

    Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2003-04-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

  9. High-Energy, High-Pulse-Rate Light Sources for Enhanced Time-Resolved Tomographic PIV of Unsteady and Turbulent Flows

    DTIC Science & Technology

    2017-07-31

    Report: High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows The views, opinions and/or...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows Report Term: 0-Other Email

  10. Computed tomographic angiography in stroke imaging: fundamental principles, pathologic findings, and common pitfalls.

    PubMed

    Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R

    2006-06-01

    The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.

  11. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...

  12. Evaluating the Predictive Validity of the Computerized Comprehension Task: Comprehension Predicts Production

    PubMed Central

    Friend, Margaret; Schmitt, Sara A.; Simpson, Adrianne M.

    2017-01-01

    Until recently, the challenges inherent in measuring comprehension have impeded our ability to predict the course of language acquisition. The present research reports on a longitudinal assessment of the convergent and predictive validity of the CDI: Words and Gestures and the Computerized Comprehension Task (CCT). The CDI: WG and the CCT evinced good convergent validity however the CCT better predicted subsequent parent reports of language production. Language sample data in the third year confirm this finding: the CCT accounted for 24% of the variance in unique word use. These studies provide evidence for the utility of a behavior-based approach to predicting the course of language acquisition into production. PMID:21928878

  13. [Application of regular expression in extracting key information from Chinese medicine literatures about re-evaluation of post-marketing surveillance].

    PubMed

    Wang, Zhifei; Xie, Yanming; Wang, Yongyan

    2011-10-01

    Computerizing extracting information from Chinese medicine literature seems more convenient than hand searching, which could simplify searching process and improve the accuracy. However, many computerized auto-extracting methods are increasingly used, regular expression is so special that could be efficient for extracting useful information in research. This article focused on regular expression applying in extracting information from Chinese medicine literature. Two practical examples were reported in this article about regular expression to extract "case number (non-terminology)" and "efficacy rate (subgroups for related information identification)", which explored how to extract information in Chinese medicine literature by means of some special research method.

  14. Computerized estimation of compatibility of stressors at work and worker's health characteristics.

    PubMed

    Susnik, J; Bizjak, B; Cestnik, B

    1996-09-01

    A system of computerized estimation of compatibility of stressors at work and worker's health characteristics is presented. Each characteristic is defined and scored on a specific scale. Incompatible workplace characteristics as related to worker's characteristics are singled out and offered to the user for an ergonomic solution. Work on the system started in 1987. This paper deals with the system's further development, which involves a larger number of topics, changes of the algorithm and presentation of an applicative case. Comparison of the system's results with those of medical experts shows that the use of the system tends to improve the thoroughness and consistency of incompatibility evaluations and consequently to make working ability assessment more objective.

  15. Image processing pipeline for synchrotron-radiation-based tomographic microscopy.

    PubMed

    Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M

    2010-07-01

    With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.

  16. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, James G.; Daily, William D.

    1994-01-01

    A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  17. 45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computerized support enforcement systems. 307.15 Section 307.15 Public Welfare Regulations Relating to Public... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.15 Approval of advance planning documents for computerized support enforcement systems. (a...

  18. Arkansas' Curriculum Guide. Competency Based Computerized Accounting.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock. Div. of Vocational, Technical and Adult Education.

    This guide contains the essential parts of a total curriculum for a one-year secondary-level course in computerized accounting. Addressed in the individual sections of the guide are the following topics: the complete accounting cycle, computer operations for accounting, computerized accounting and general ledgers, computerized accounts payable,…

  19. Clinical applications with the HIDAC positron camera

    NASA Astrophysics Data System (ADS)

    Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.

    1988-06-01

    A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.

  20. GPS tomographic experiment on water vapour dynamics in the troposphere over Lisbon

    NASA Astrophysics Data System (ADS)

    Benevides, Pedro; Catalao, Joao; Miranda, Pedro

    2015-04-01

    Quantification of the water vapour variability on the atmosphere remains a difficult task, affecting the weather prediction. Coarse water vapour resolution measurements in space and time affect the numerical weather prediction solution models causing artifacts in the prediction of severe weather phenomena. The GNSS atmospheric processing has been developed in the past years providing integrated water vapour estimates comparable with the meteorological sensor measurements, with studies registering 1 to 2 kg/m2 bias, but lack a vertical determination of the atmospheric processes. The GNSS tomography in the troposphere is one of the most promising techniques for sensing the three-dimensional water vapour state of the atmosphere. The determination of the integrated water vapour profile by means of the widely accepted GNSS meteorology techniques, allows the reconstruction of several slant path delay rays in the satellite line of view, providing an opportunity to sense the troposphere at tree-dimensions plus time. The tomographic system can estimate an image solution of the water vapour but impositions have to be introduced to the system of equations inversion because of the non-optimal GNSS observation geometry. Application of this technique on atmospheric processes like large convective precipitation or mesoscale water vapour circulation have been able to describe its local dynamic vertical variation. A 3D tomographic experiment was developed over an area of 60x60 km2 around Lisbon (Portugal). The GNSS network available composed by 9 receivers was used for an experiment of densification of the permanent network using 8 temporarily installed GPS receivers (totalling 17 stations). This study was performed during several weeks in July 2013, where a radiosonde campaign was also held in order to validate the tomographic inversion solution. 2D integrated water vapour maps directly obtained from the GNSS processing were also evaluated and local coastal breeze circulation patterns were identified. Preliminary results show good agreement between radiosonde vertical profiles of water vapour and the correspondent grid columnar profile of the tomographic solution. This study aims for a preliminary characterization of the 3D water vapour field over this region, investigating its potential for monitor small scale air circulation on coastal areas like sea breeze meteorological phenomenon. This study was funded by the Portuguese Science Foundation FCT, under project SMOG PTDC/CTE-ATM/119922/2010 and PhD grant SFRH/BD/80288/2011.

  1. 4D Arctic: A Glimpse into the Structure and Evolution of the Arctic in the Light of New Geophysical Maps, Plate Tectonics and Tomographic Models.

    PubMed

    Gaina, Carmen; Medvedev, Sergei; Torsvik, Trond H; Koulakov, Ivan; Werner, Stephanie C

    Knowledge about the Arctic tectonic structure has changed in the last decade as a large number of new datasets have been collected and systematized. Here, we review the most updated, publicly available Circum-Arctic digital compilations of magnetic and gravity data together with new models of the Arctic's crust. Available tomographic models have also been scrutinized and evaluated for their potential to reveal the deeper structure of the Arctic region. Although the age and opening mechanisms of the Amerasia Basin are still difficult to establish in detail, interpreted subducted slabs that reside in the High Arctic's lower mantle point to one or two episodes of subduction that consumed crust of possibly Late Cretaceous-Jurassic age. The origin of major igneous activity during the Cretaceous in the central Arctic (the Alpha-Mendeleev Ridge) and in the proximity of rifted margins (the so-called High Arctic Large Igneous Province-HALIP) is still debated. Models of global plate circuits and the connection with the deep mantle are used here to re-evaluate a possible link between Arctic volcanism and mantle plumes.

  2. Roles of Transesophageal Echocardiography and Cardiac Computed Tomography for Evaluation of Left Atrial Thrombus and Associated Pathology: A Review and Critical Analysis.

    PubMed

    Pathan, Faraz; Hecht, Harvey; Narula, Jagat; Marwick, Thomas H

    2018-04-01

    Evaluation of the left atrium and left atrial appendage for the presence of thrombus prior to cardioversion and pulmonary vein isolation, and of the entire heart for embolic sources in the setting of cryptogenic stroke, has long been standard medical care. Guidelines have uniformly recommended transesophageal echocardiography (TEE) to accomplish these goals. In recent years, computed tomographic angiography has demonstrated diagnostic accuracy similar to that of TEE for the detection of thrombus. Analysis of the pertinent data and relative merits of the 2 technologies leads to the conclusions that: 1) both modalities have some unique, nonoverlapping capabilities that may dictate their use in specific situations; 2) computed tomographic angiography is a reasonable alternative to TEE when the primary aim is to exclude left atrial and left atrial appendage thrombus and in patients in whom the risks associated with TEE outweigh the benefits; and 3) both options should be discussed with the patient in the setting of shared decision making. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Prevention of prescription errors by computerized, on-line, individual patient related surveillance of drug order entry.

    PubMed

    Oliven, A; Zalman, D; Shilankov, Y; Yeshurun, D; Odeh, M

    2002-01-01

    Computerized prescription of drugs is expected to reduce the number of many preventable drug ordering errors. In the present study we evaluated the usefullness of a computerized drug order entry (CDOE) system in reducing prescription errors. A department of internal medicine using a comprehensive CDOE, which included also patient-related drug-laboratory, drug-disease and drug-allergy on-line surveillance was compared to a similar department in which drug orders were handwritten. CDOE reduced prescription errors to 25-35%. The causes of errors remained similar, and most errors, on both departments, were associated with abnormal renal function and electrolyte balance. Residual errors remaining on the CDOE-using department were due to handwriting on the typed order, failure to feed patients' diseases, and system failures. The use of CDOE was associated with a significant reduction in mean hospital stay and in the number of changes performed in the prescription. The findings of this study both quantity the impact of comprehensive CDOE on prescription errors and delineate the causes for remaining errors.

  4. Computerized Measurement of Negative Symptoms in Schizophrenia

    PubMed Central

    Cohen, Alex S.; Alpert, Murray; Nienow, Tasha M.; Dinzeo, Thomas J.; Docherty, Nancy M.

    2008-01-01

    Accurate measurement of negative symptoms is crucial for understanding and treating schizophrenia. However, current measurement strategies are reliant on subjective symptom rating scales which often have psychometric and practical limitations. Computerized analysis of patients’ speech offers a sophisticated and objective means of evaluating negative symptoms. The present study examined the feasibility and validity of using widely-available acoustic and lexical-analytic software to measure flat affect, alogia and anhedonia (via positive emotion). These measures were examined in their relationships to clinically-rated negative symptoms and social functioning. Natural speech samples were collected and analyzed for 14 patients with clinically-rated flat affect, 46 patients without flat affect and 19 healthy controls. The computer-based inflection and speech rate measures significantly discriminated patients with flat affect from controls, and the computer-based measure of alogia and negative emotion significantly discriminated the flat and non-flat patients. Both the computer and clinical measures of positive emotion/anhedonia corresponded to functioning impairments. The computerized method of assessing negative symptoms offered a number of advantages over the symptom scale-based approach. PMID:17920078

  5. COMPUTERIZED ASSESSMENT OF HUMAN NEUROTOXICITY: SENSITIVITY TO NITROUS OXIDE EXPOSURE

    EPA Science Inventory

    The authors recently developed a flexible, portable, computer based neurobehavioral evaluation system (NES) to standardize data collection in epidemiologic field studies of individuals at risk for neurobehavioral toxicity. The current study was performed to examine the system's s...

  6. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    USGS Publications Warehouse

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  7. Business aspects of cardiovascular computed tomography: tackling the challenges.

    PubMed

    Bateman, Timothy M

    2008-01-01

    The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.

  8. 3D "spectracoustic" system: a modular, tomographic, spectroscopic mapping imaging, non-invasive, diagnostic system for detection of small starting developing tumors like melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios

    2017-03-01

    This work led to a new method named 3D spectracoustic tomographic mapping imaging. The current and the future work is related to the fabrication of a combined acoustic microscopy transducer and infrared illumination probe permitting the simultaneous acquisition of the spectroscopic and the tomographic information. This probe provides with the capability of high fidelity and precision registered information from the combined modalities named spectracoustic information.

  9. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    DTIC Science & Technology

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow...2001). 6. K. M. Tacina and W. J. A. Dahm, “Effects of heat release on turbulent shear flows, Part 1. A general equivalence principle for non-buoyant

  10. Tomographic diffractive microscopy with agile illuminations for imaging targets in a noisy background.

    PubMed

    Zhang, T; Godavarthi, C; Chaumet, P C; Maire, G; Giovannini, H; Talneau, A; Prada, C; Sentenac, A; Belkebir, K

    2015-02-15

    Tomographic diffractive microscopy is a marker-free optical digital imaging technique in which three-dimensional samples are reconstructed from a set of holograms recorded under different angles of incidence. We show experimentally that, by processing the holograms with singular value decomposition, it is possible to image objects in a noisy background that are invisible with classical wide-field microscopy and conventional tomographic reconstruction procedure. The targets can be further characterized with a selective quantitative inversion.

  11. Diagnostic value of QRS and S wave variation in patients with suspicion of acute pulmonary embolism.

    PubMed

    Çağdaş, Metin; Karakoyun, Süleyman; Rencüzoğulları, İbrahim; Karabağ, Yavuz; Artaç, İnanç; İliş, Doğan; Hamideyin, Şerif; Karayol, Sibel; Çiftçi, Handan; Çınar, Tufan

    2018-03-29

    This study aimed to investigate the diagnostic value of QRS and S wave variation in patients admitted to the emergency department with suspicion of acute pulmonary embolism (APE). Computerized tomographic pulmonary angiography (CTPA) was performed in 118 consecutive patients to evaluate patients with suspected APE, and 106 subjects with appropriate electrocardiogram and CT images constituted the study population. Using CTPA, APE was diagnosed in 48.1% (n:51) of the study population. The comparison of patients with APE and those without APE revealed that increased heart rate, right axis deviation of QRS axis, complete or incomplete right bundle branch block, prominent S wave in lead D1, increased QRS duration, percentage of QRS (9,8[4,8-19,0] vs 3,8[2,7-71]; p<0,001), S wave variation (22,3[9,6-31,9] vs 4,8 [2-8]; p<0,001) and ΔS wave amplitude (1.1[0.5-1.5] vs 0.2[0.1-0.5]; p<0.001) were significantly associated with APE, but no relationship was detected with respect to the presence of atrial arrhythmias, clockwise rotation of the horizontal axis, fragmentation, ST segment deviation, T wave inversion, and S1Q3T3 and S1S2S3 patterns. The percentage of S wave variation (OR: 1072 per 1% increase, 95% CI:1011-1137) was found to be an independent predictor of APE. ΔS wave amplitude>0.5mm predicted APE with a sensitivity of 72.6% and a specificity of 74.6% (AUC:0.805, 95% CI: 0.717-0.876; p<0.001). The present study demonstrated that QRS and S wave variation could be useful electrocardiographic signs for the diagnosis of APE. Copyright © 2018. Published by Elsevier Inc.

  12. PubMed Central

    FOUNTOULAKIS, E.N.; PAPADAKI, E.; PANAGIOTAKI, I.; GIANNIKAKI, E.; LAGOUDIANAKIS, G.; BIZAKIS, J.

    2011-01-01

    SUMMARY Haemangiopericytoma is a rare soft tissue tumour, with great histological variability and unpredictable clinical and biological behaviour. The precise cell type origin is uncertain. One third of haemangiopericytomas occur in the head and neck area, but only a few cases have been reported regarding localization at the parapharyngeal space. Herewith, case is presented of a 54-year-old female, referred to our Department due to a parapharyngeal space tumour with non-specific imaging characteristics. The patient underwent radical excision of the tumour with a trans-cervical sub-mandibular approach. The histolopathologic examination revealed a neoplasm with the characteristic features of haemangiopericytoma. One year later, during the scheduled follow-up, the computerized tomography scan showed no evidence of recurrence or residual disease. The pre-operative evaluation of a haemangiopericytoma must include a thorough imaging evaluation with computerized tomography and magnetic resonance imaging, even if results may not be specific for haemangiopericytoma. Angiography and pre-operative embolization may be performed in cases of large tumours with significant vascularity. The treatment of choice is radical excision. The follow-up includes clinical evaluation every 6 months and annual magnetic resonance imaging for at least 3 years. PMID:22058597

  13. A computerized system to evaluate volumetric infusion pumps.

    PubMed

    Kobayashi, S; Ogata, T

    1992-01-01

    A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.

  14. Reliability and validity of the Arabic version of the computerized Battery for Neuropsychological Evaluation of Children (BENCI).

    PubMed

    Fasfous, Ahmed F; Peralta-Ramirez, Maria Isabel; Pérez-Marfil, María Nieves; Cruz-Quintana, Francisco; Catena-Martinez, Andrés; Pérez-García, Miguel

    2015-01-01

    Batería de Evaluación Neuropsicológica Infantil (BENCI) is a computerized battery for the neuropsychological evaluation of children. This battery has been used in different studies to evaluate neuropsychological functions and neurodevelopment in children. The objective of this study is to test the validity and reliability of the first Arabic version of the BENCI on an Arabic population where neuropsychological tests are very scarce. We administrate the BENCI to 198 school-age children (98 boys and 100 girls) from Morocco. To examine the test retest reliability of the BENCI battery, we administered the battery 2 times to 43 children (23 boys and 20 girls) with 15 days in between the pre- and posttest. The results revealed good validity and reliability of the battery in Arabic children. Also, the BENCI battery has demonstrated the capacity to differentiate between children by their age group. This battery can be of great use to both the research and clinical areas of Arabic countries and/or in assistance to Arabic immigrants that live outside of their native country.

  15. Formative evaluation of a multimedia self-administered computerized hearing loss prevention program.

    PubMed

    Saunders, Gabrielle H; Vachhani, Jay J; Galvez, Gino; Griest, Susan E

    2015-04-01

    To determine which features make a computer-based hearing health education intervention effective, easy to use, and enjoyable. The study examined which features of a multimedia self-administered computerized hearing loss prevention program, developed by the National Center for Rehabilitative Auditory Research (referred to as the NCRAR-HLPP), users liked and disliked, and the reasons why. A formative evaluation was conducted in which participants completed a questionnaire to assess knowledge and attitudes towards hearing and hearing loss prevention, used the NCRAR-HLPP, completed the questionnaire for a second time, and were interviewed to learn their opinions about the NCRAR-HLPP. Twenty-five male and four female Veterans recruited from the Portland VA Medical Center who were aged between 25 and 65 years. Participants reported that using the NCRAR-HLPP was a positive experience. Ease of use, multimedia content, personal relevance, and use of emotion were positive features of the program. The questionnaire showed increased knowledge and improved attitude scores following use of the program. This formative evaluation showed changes designed to target user preferences and improve user instructions will be made in future versions of the program.

  16. SITEQUAL--A User's Guide: Computerized Site Evaluation for 14 Southern Hardwood Species

    Treesearch

    Constance A. Harrington; Bettina M. Casson

    1986-01-01

    An interactive computer program, SITEQUAL, has been developed from the widely-used Baker and Broadfoot field guides, which evaluate site quality for 14 southern hardwood tree species. The SITEQUAL program calculates site index for all species simultaneously and provides a breakdown of site index into the component contributions by each of the four major soil factors...

  17. Evaluation of the VA's Pilot Program in Institutional Reorganization toward Primary and Ambulatory Care: Part I, Changes in the Process and Outcomes of Care.

    ERIC Educational Resources Information Center

    Rubenstein, Lisa V.; And Others

    1996-01-01

    A study evaluated the impact of the reorganization of the academic Sepulveda (California) Veterans' Administration medical center toward primary and ambulatory care. Surveys of several thousand patients were linked to computerized utilization and mortality data and related to the center's strategic plan and goals. Substantial improvement in…

  18. Richardson Instructional Management System (RIMS). How to Blend a Computerized Objectives-Referenced Testing System, Distributive Data Processing, and Systemwide Evaluation.

    ERIC Educational Resources Information Center

    Riegel, N. Blyth

    Recent changes in the structure of curriculum and the instructional system in Texas have required a major reorganization of teaching, evaluating, budgeting, and planning activities in the local education agencies, which has created the need for a database. The history of Richardson Instructional Management System (RIMS), its data processing…

  19. Evaluation of Automated Natural Language Processing in the Further Development of Science Information Retrieval. String Program Reports No. 10.

    ERIC Educational Resources Information Center

    Sager, Naomi

    This investigation matches the emerging techniques in computerized natural language processing against emerging needs for such techniques in the information field to evaluate and extend such techniques for future applications and to establish a basis and direction for further research toward these goals. An overview describes developments in the…

  20. Assessment, evaluation, and testing of technologies for environmental restoration, decontamination, and decommissioning and high level waste management. Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uzochukwu, G.A.

    1997-12-31

    Nuclear and commercial non-nuclear technologies that have the potential of meeting the environmental restoration, decontamination and decommissioning, and high-level waste management objectives are being assessed and evaluated. A detailed comparison of innovative technologies available will be performed to determine the safest and most economical technology for meeting these objectives. Information derived from this effort will be matched with the multi-objectives of the environmental restoration, decontamination and decommissioning, and high-level waste management effort to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formattedmore » and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formatted and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the safest and most economical technologies are developed for use at SRS and other DOE sites.« less

  1. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    ERIC Educational Resources Information Center

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  2. A Randomized Controlled Trial of the "Cool Teens" CD-ROM Computerized Program for Adolescent Anxiety

    ERIC Educational Resources Information Center

    Wuthrich, Viviana M.; Rapee, Ronald M.; Cunningham, Michael J.; Lyneham, Heidi J.; Hudson, Jennifer L.; Schniering, Carolyn A.

    2012-01-01

    Objective: Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This…

  3. Combining computerized social cognitive training with neuroplasticity-based auditory training in schizophrenia.

    PubMed

    Sacks, Stephanie; Fisher, Melissa; Garrett, Coleman; Alexander, Phillip; Holland, Christine; Rose, Demian; Hooker, Christine; Vinogradov, Sophia

    2013-01-01

    Social cognitive deficits are an important treatment target in schizophrenia, but it is unclear to what degree they require specialized interventions and which specific components of behavioral interventions are effective. In this pilot study, we explored the effects of a novel computerized neuroplasticity-based auditory training delivered in conjunction with computerized social cognition training (SCT) in patients with schizophrenia. Nineteen clinically stable schizophrenia subjects performed 50 hours of computerized exercises that place implicit, increasing demands on auditory perception, plus 12 hours of computerized training in emotion identification, social perception, and theory of mind tasks. All subjects were assessed with MATRICS-recommended measures of neurocognition and social cognition, plus a measure of self-referential source memory before and after the computerized training. Subjects showed significant improvements on multiple measures of neurocognition. Additionally, subjects showed significant gains on measures of social cognition, including the MSCEIT Perceiving Emotions, MSCEIT Managing Emotions, and self-referential source memory, plus a significant decrease in positive symptoms. Computerized training of auditory processing/verbal learning in schizophrenia results in significant basic neurocognitive gains. Further, addition of computerized social cognition training results in significant gains in several social cognitive outcome measures. Computerized cognitive training that directly targets social cognitive processes can drive improvements in these crucial functions.

  4. Limited-angle tomography for analyzer-based phase-contrast X-ray imaging

    PubMed Central

    Majidi, Keivan; Wernick, Miles N; Li, Jun; Muehleman, Carol; Brankov, Jovan G

    2014-01-01

    Multiple-Image Radiography (MIR) is an analyzer-based phase-contrast X-ray imaging method (ABI), which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume. PMID:24898008

  5. Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

    NASA Astrophysics Data System (ADS)

    Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.

    2014-07-01

    Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.

  6. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    PubMed

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge after sedation.

  7. Comparison between Long-Menu and Open-Ended Questions in computerized medical assessments. A randomized controlled trial

    PubMed Central

    Rotthoff, Thomas; Baehring, Thomas; Dicken, Hans-Dieter; Fahron, Urte; Richter, Bernd; Fischer, Martin R; Scherbaum, Werner A

    2006-01-01

    Background Long-menu questions (LMQs) are viewed as an alternative method for answering open-ended questions (OEQs) in computerized assessment. So far this question type and its influence on examination scores have not been studied sufficiently. However, the increasing use of computerized assessments will also lead to an increasing use of this question type. Using a summative online key feature (KF) examination we evaluated whether LMQs can be compared with OEQs in regard to the level of difficulty, performance and response times. We also evaluated the content for its suitability for LMQs. Methods We randomized 146 fourth year medical students into two groups. For the purpose of this study we created 7 peer-reviewed KF-cases with a total of 25 questions. All questions had the same content in both groups, but nine questions had a different answer type. Group A answered 9 questions with an LM type, group B with an OE type. In addition to the LM answer, group A could give an OE answer if the appropriate answer was not included in the list. Results The average number of correct answers for LMQs and OEQs showed no significant difference (p = 0.93). Among all 630 LM answers only one correct term (0.32%) was not included in the list of answers. The response time for LMQs did not significantly differ from that of OEQs (p = 0.65). Conclusion LMQs and OEQs do not differ significantly. Compared to standard multiple-choice questions (MCQs), the response time for LMQs and OEQs is longer. This is probably due to the fact that they require active problem solving skills and more practice. LMQs correspond more suitable to Short answer questions (SAQ) then to OEQ and should only be used when the answers can be clearly phrased, using only a few, precise synonyms. LMQs can decrease cueing effects and significantly simplify the scoring in computerized assessment. PMID:17032439

  8. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    PubMed

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  9. Management of seizures in the elderly: a survey of UK geriatricians.

    PubMed Central

    Stolarek, I H; Brodie, A F; Brodie, M J

    1995-01-01

    The incidence and prevalence of epilepsy increase substantially with old age. Despite this, the investigation and management of this patient population remains a grey area. Four hundred and eleven (53%) consultant geriatricians responded to a questionnaire exploring their approach to seizures in the elderly in order to establish an overview of current clinical practice. Between one and five patients presenting with seizures, predominantly aged between 75-85 years, were reviewed monthly. Seventy per cent of geriatricians undertook to investigate the patients themselves with biochemical and haematological profiles performed by most. Electroencephalography and computerized tomographic scanning were routinely requested by a quarter of responders. Only 58% would themselves initiate therapy with antiepileptic drugs, with 16% of consultants starting treatment following the first seizure, 59% after a second and 5% after a third. Phenytoin was first choice for generalized tonic-clonic seizures with carbamazepine preferred for partial seizures. If good control was not obtained, 67% would substitute another first line drug, while 27% would add in a second. Less than 3% would use the new anticonvulsants lamotrigine or vigabatrin. Sixty per cent monitored anticonvulsant concentrations in patients with poor control or suspected toxicity. A wide variability was seen in the current approach to seizures in the elderly, which reflects a lack of established practice. Epilepsy clinics for the elderly would encourage structured research into the many unanswered questions affecting the care of older people with seizures. PMID:8786590

  10. Successful Resection of a Large Carotid Body Tumor Masquerading Complete Encasement of the Internal Carotid Artery on Preoperative Imaging.

    PubMed

    Kakkos, Stavros K; Zampakis, Peter; Lampropoulos, George C; Paridis, Leonidas; Kaplanis, Charalampos; Bantouna, Dimitra; Nikolakopoulos, Konstantinos M; Papageorgopoulou, Chrysanthi P; Kalogeropoulou, Christina; Tsolakis, Ioannis A

    2018-05-01

    A 41-year-old woman presented with a large painful and tender mass of the left side of her neck located just below the angle of the mandible. She was also complaining of frequent attacks of symptoms ranging from dizziness upon resuming the erect position to frank syncope. Color-coded duplex showed a large well-vascularized vascular mass at the level of the carotid bifurcation, suggesting the diagnosis of a carotid body tumor (CBT). A computerized tomographic angiography confirmed the diagnosis of a CBT, which measured 5.7 cm in its craniocaudal axis. The tumor appeared to encase the internal carotid artery (ICA) at the level of its origin, indicating the presence of a Shamblin group 3 tumor. During surgery, the CBT seemingly encased the ICA; however, it was successfully taken off the ICA, by establishing an adventitial dissection place, obviating the need for arterial resection and replacement. A brief intraoperative episode of cardiac arrest was successfully managed. Postoperative course was uneventful, and all symptoms were cured. Pathology confirmed the clinical diagnosis and did not show malignancy. In conclusion, meticulous surgical techniques can spare the ICA from removal or inadvertent injury during CBT surgery and reduce the morbidity often associated with the resection of large or advanced tumors but also cure atypical patient symptoms.

  11. Regional model-based computerized ionospheric tomography using GPS measurements: IONOLAB-CIT

    NASA Astrophysics Data System (ADS)

    Tuna, Hakan; Arikan, Orhan; Arikan, Feza

    2015-10-01

    Three-dimensional imaging of the electron density distribution in the ionosphere is a crucial task for investigating the ionospheric effects. Dual-frequency Global Positioning System (GPS) satellite signals can be used to estimate the slant total electron content (STEC) along the propagation path between a GPS satellite and ground-based receiver station. However, the estimated GPS-STEC is very sparse and highly nonuniformly distributed for obtaining reliable 3-D electron density distributions derived from the measurements alone. Standard tomographic reconstruction techniques are not accurate or reliable enough to represent the full complexity of variable ionosphere. On the other hand, model-based electron density distributions are produced according to the general trends of ionosphere, and these distributions do not agree with measurements, especially for geomagnetically active hours. In this study, a regional 3-D electron density distribution reconstruction method, namely, IONOLAB-CIT, is proposed to assimilate GPS-STEC into physical ionospheric models. The proposed method is based on an iterative optimization framework that tracks the deviations from the ionospheric model in terms of F2 layer critical frequency and maximum ionization height resulting from the comparison of International Reference Ionosphere extended to Plasmasphere (IRI-Plas) model-generated STEC and GPS-STEC. The suggested tomography algorithm is applied successfully for the reconstruction of electron density profiles over Turkey, during quiet and disturbed hours of ionosphere using Turkish National Permanent GPS Network.

  12. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    PubMed

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  13. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, J.G.; Daily, W.D.

    1994-07-05

    A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  14. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    PubMed Central

    Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo

    2016-01-01

    This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041

  15. High-Tech Roof Management.

    ERIC Educational Resources Information Center

    Benzie, Tim

    1997-01-01

    Describes the use of a computerized roof management system (CRMS) for school districts to foster multiple roof maintenance efficiency and cost effectiveness. Highlights CRMS software manufacturer choices, as well as the types of nondestructive testing equipment tools that can be used to evaluate roof conditions. (GR)

  16. 45 CFR 310.40 - What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...

  17. Accuracy of a computerized clinical decision-support system for asthma assessment and management.

    PubMed

    Hoeksema, Laura J; Bazzy-Asaad, Alia; Lomotan, Edwin A; Edmonds, Diana E; Ramírez-Garnica, Gabriela; Shiffman, Richard N; Horwitz, Leora I

    2011-05-01

    To evaluate the accuracy of a computerized clinical decision-support system (CDSS) designed to support assessment and management of pediatric asthma in a subspecialty clinic. Cohort study of all asthma visits to pediatric pulmonology from January to December, 2009. CDSS and physician assessments of asthma severity, control, and treatment step. Both the clinician and the computerized CDSS generated assessments of asthma control in 767/1032 (74.3%) return patients, assessments of asthma severity in 100/167 (59.9%) new patients, and recommendations for treatment step in 66/167 (39.5%) new patients. Clinicians agreed with the CDSS in 543/767 (70.8%) of control assessments, 37/100 (37%) of severity assessments, and 19/66 (29%) of step recommendations. External review classified 72% of control disagreements (21% of all control assessments), 56% of severity disagreements (37% of all severity assessments), and 76% of step disagreements (54% of all step recommendations) as CDSS errors. The remaining disagreements resulted from pulmonologist error or ambiguous guidelines. Many CDSS flaws, such as attributing all 'cough' to asthma, were easily remediable. Pediatric pulmonologists failed to follow guidelines in 8% of return visits and 18% of new visits. The authors relied on chart notes to determine clinical reasoning. Physicians may have changed their assessments after seeing CDSS recommendations. A computerized CDSS performed relatively accurately compared to clinicians for assessment of asthma control but was inaccurate for treatment. Pediatric pulmonologists failed to follow guideline-based care in a small proportion of patients.

  18. Computerized counseling reduces HIV-1 viral load and sexual transmission risk: findings from a randomized controlled trial.

    PubMed

    Kurth, Ann E; Spielberg, Freya; Cleland, Charles M; Lambdin, Barrot; Bangsberg, David R; Frick, Pamela A; Severynen, Anneleen O; Clausen, Marc; Norman, Robert G; Lockhart, David; Simoni, Jane M; Holmes, King K

    2014-04-15

    Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Longitudinal randomized controlled trial. An academic HIV clinic and a community-based organization in Seattle. In a total of 240 HIV-positive adults on ART, 209 completed 9-month follow-up (87% retention). Randomization to computerized counseling or assessment only, 4 sessions over 9 months. HIV-1 viral suppression, and self-reported ART adherence and transmission risks, compared using generalized estimating equations. Overall, intervention participants had reduced viral load: mean 0.17 log10 decline, versus 0.13 increase in controls, P = 0.053, and significant difference in ART adherence baseline to 9 months (P = 0.046). Their sexual transmission risk behaviors decreased (odds ratio = 0.55, P = 0.020), a reduction not seen among controls (odds ratio = 1.1, P = 0.664), and a significant difference in change (P = 0.040). Intervention effect was driven by those most in need; among those with detectable virus at baseline (>30 copies/mL, n = 89), intervention effect was mean 0.60 log10 viral load decline versus 0.15 increase in controls, P = 0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, P = 0.038. Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior.

  19. Computerized cytometry and wavelet analysis of follicular lesions for detecting malignancy: A pilot study in thyroid cytology.

    PubMed

    Gilshtein, Hayim; Mekel, Michal; Malkin, Leonid; Ben-Izhak, Ofer; Sabo, Edmond

    2017-01-01

    The cytologic diagnosis of indeterminate lesions of the thyroid involves much uncertainty, and the final diagnosis often requires operative resection. Computerized cytomorphometry and wavelets analysis were examined to evaluate their ability to better discriminate between benign and malignant lesions based on cytology slides. Cytologic reports from patients who underwent thyroid operation in a single, tertiary referral center were retrieved. Patients with Bethesda III and IV lesions were divided according to their final histopathology. Cytomorphometry and wavelet analysis were performed on the digitized images of the cytology slides. Cytology slides of 40 patients were analyzed. Seven patients had a histologic diagnosis of follicular malignancy, 13 had follicular adenomas, and 20 had a benign goiter. Computerized cytomorphometry with a combination of descriptors of nuclear size, shape, and texture was able to predict quantitatively adenoma versus malignancy within the indeterminate group with 95% accuracy. An automated wavelets analysis with a neural network algorithm reached an accuracy of 96% in identifying correctly malignant vs. benign lesions based on cytology. Computerized analysis of cytology slides seems to be more accurate in defining indeterminate thyroid lesions compared with conventional cytologic analysis, which is based on visual characteristics on cytology as well as the expertise of the cytologist. This pilot study needs to be validated with a greater number of samples. Providing a successful validation, we believe that such methods carry promise for better patient treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Normal computerized Q wave measurements in healthy young athletes.

    PubMed

    Saini, Divakar; Grober, Aaron F; Hadley, David; Froelicher, Victor

    Recent Expert consensus statements have sought to decrease false positive rates of electrocardiographic abnormalities requiring further evaluation when screening young athletes. These statements are largely based on traditional ECG patterns and have not considered computerized measurements. To define the normal limits for Q wave measurements from the digitally recorded ECGs of healthy young athletes. All athletes were categorized by sex and level of participation (high school, college, and professional), and underwent screening ECGs with routine pre-participation physicals, which were electronically captured and analyzed. Q wave amplitude, area and duration were recorded for athletes with Q wave amplitudes greater than 0.5mm at standard paper amplitude display (1mV/10mm). ANOVA analyses were performed to determine differences these parameters among all groups. A positive ECG was defined by our Stanford Computerized Criteria as exceeding the 99th percentile for Q wave area in 2 or more leads. Proportions testing was used to compare the Seattle Conference Q wave criteria with our data-driven criteria. 2073 athletes in total were screened. Significant differences in Q wave amplitude, duration and area were identified both by sex and level of participation. When applying our Stanford Computerized Criteria and the Seattle criteria to our cohort, two largely different groups of athletes are identified as having abnormal Q waves. Computer analysis of athletes' ECGs should be included in future studies that have greater numbers, more diversity and adequate end points. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Towards a Framework for Developing Semantic Relatedness Reference Standards

    PubMed Central

    Pakhomov, Serguei V.S.; Pedersen, Ted; McInnes, Bridget; Melton, Genevieve B.; Ruggieri, Alexander; Chute, Christopher G.

    2010-01-01

    Our objective is to develop a framework for creating reference standards for functional testing of computerized measures of semantic relatedness. Currently, research on computerized approaches to semantic relatedness between biomedical concepts relies on reference standards created for specific purposes using a variety of methods for their analysis. In most cases, these reference standards are not publicly available and the published information provided in manuscripts that evaluate computerized semantic relatedness measurement approaches is not sufficient to reproduce the results. Our proposed framework is based on the experiences of medical informatics and computational linguistics communities and addresses practical and theoretical issues with creating reference standards for semantic relatedness. We demonstrate the use of the framework on a pilot set of 101 medical term pairs rated for semantic relatedness by 13 medical coding experts. While the reliability of this particular reference standard is in the “moderate” range; we show that using clustering and factor analyses offers a data-driven approach to finding systematic differences among raters and identifying groups of potential outliers. We test two ontology-based measures of relatedness and provide both the reference standard containing individual ratings and the R program used to analyze the ratings as open-source. Currently, these resources are intended to be used to reproduce and compare results of studies involving computerized measures of semantic relatedness. Our framework may be extended to the development of reference standards in other research areas in medical informatics including automatic classification, information retrieval from medical records and vocabulary/ontology development. PMID:21044697

  2. Effectiveness of computerized clinical decision support systems for asthma and chronic obstructive pulmonary disease in primary care: a systematic review.

    PubMed

    Fathima, Mariam; Peiris, David; Naik-Panvelkar, Pradnya; Saini, Bandana; Armour, Carol Lyn

    2014-12-02

    The use of computerized clinical decision support systems may improve the diagnosis and ongoing management of chronic diseases, which requires recurrent visits to multiple health professionals, disease and medication monitoring and modification of patient behavior. The aim of this review was to systematically review randomized controlled trials evaluating the effectiveness of computerized clinical decision systems (CCDSS) in the care of people with asthma and COPD. Randomized controlled trials published between 2003 and 2013 were searched using multiple electronic databases Medline, EMBASE, CINAHL, IPA, Informit, PsychINFO, Compendex, and Cochrane Clinical Controlled Trials Register databases. To be included, RCTs had to evaluate the role of the CCDSSs for asthma and/or COPD in primary care. Nineteen studies representing 16 RCTs met our inclusion criteria. The majority of the trials were conducted in patients with asthma. Study quality was generally high. Meta-analysis was not conducted because of methodological and clinical heterogeneity. The use of CCDSS improved asthma and COPD care in 14 of the 19 studies reviewed (74%). Nine of the nineteen studies showed statistically significant (p < 0.05) improvement in the primary outcomes measured. The majority of the studies evaluated health care process measures as their primary outcomes (10/19). Evidence supports the effectiveness of CCDSS in the care of people with asthma. However there is very little information of its use in COPD care. Although there is considerable improvement in the health care process measures and clinical outcomes through the use of CCDSSs, its effects on user workload and efficiency, safety, costs of care, provider and patient satisfaction remain understudied.

  3. Effects of computerized decision support systems on blood glucose regulation in critically ill surgical patients.

    PubMed

    Fogel, Sandy L; Baker, Christopher C

    2013-04-01

    The use of computerized decision support systems (CDSS) in glucose control for critically ill surgical patients has been reported in both diabetic and nondiabetic patients. Prospective studies evaluating its effect on glucose control are, however, lacking. The objective of this study was to evaluate patient-specific computerized IV insulin dosing on blood glucose levels (BGLs) by comparing patients treated pre-CDSS with those treated post-CDSS. A prospective study was performed in 4 surgical ICUs and 1 progressive care unit comparing patient data pre- and post-implementation of CDSS. The primary outcomes measures were the impact of the CDSS on glycemic control in this population and on reducing the incidence of severe hypoglycemia. Data on 1,682 patient admissions were evaluated, which corresponded to 73,290 BGLs post-CDSS compared with 44,972 BGLs pre-CDSS. The percentage of hyperglycemic events improved, with BGLs of >150 mg/dL decreasing by 50% compared with 6-month historical controls during the 18-month study period from July 2010 through December 2011. This was true for all 5 units individually (p < 0.0001, by one sample sign test). In addition, severe hypoglycemia (defined as BGL <40 mg/dL) decreased from 1% to 0.05% after implementing CDSS (p < 0.0001 by 2-sided binomial test). Patients whose BGLs were managed using CDSS were statistically significantly more likely to have a glucose reading under control (<150 mg/dL) than in the 6-month historical controls and to avoid serious hypoglycemia (p < 0.0001). Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. New method of scoliosis assessment: preliminary results using computerized photogrammetry.

    PubMed

    Aroeira, Rozilene Maria Cota; Leal, Jefferson Soares; de Melo Pertence, Antônio Eustáquio

    2011-09-01

    A new method for nonradiographic evaluation of scoliosis was independently compared with the Cobb radiographic method, for the quantification of scoliotic curvature. To develop a protocol for computerized photogrammetry, as a nonradiographic method, for the quantification of scoliosis, and to mathematically relate this proposed method with the Cobb radiographic method. Repeated exposure to radiation of children can be harmful to their health. Nevertheless, no nonradiographic method until now proposed has gained popularity as a routine method for evaluation, mainly due to a low correspondence to the Cobb radiographic method. Patients undergoing standing posteroanterior full-length spine radiographs, who were willing to participate in this study, were submitted to dorsal digital photography in the orthostatic position with special surface markers over the spinous process, specifically the vertebrae C7 to L5. The radiographic and photographic images were sent separately for independent analysis to two examiners, trained in quantification of scoliosis for the types of images received. The scoliosis curvature angles obtained through computerized photogrammetry (the new method) were compared to those obtained through the Cobb radiographic method. Sixteen individuals were evaluated (14 female and 2 male). All presented idiopathic scoliosis, and were between 21.4 ± 6.1 years of age; 52.9 ± 5.8 kg in weight; 1.63 ± 0.05 m in height, with a body mass index of 19.8 ± 0.2. There was no statistically significant difference between the scoliosis angle measurements obtained in the comparative analysis of both methods, and a mathematical relationship was formulated between both methods. The preliminary results presented demonstrate equivalence between the two methods. More studies are needed to firmly assess the potential of this new method as a coadjuvant tool in the routine following of scoliosis treatment.

  5. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    PubMed

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  6. Rheumatoid arthritis-related interstitial lung disease (RA-ILD): methotrexate and the severity of lung disease are associated to prognosis.

    PubMed

    Rojas-Serrano, Jorge; Herrera-Bringas, Denisse; Pérez-Román, Diana I; Pérez-Dorame, Renzo; Mateos-Toledo, Heidegger; Mejía, Mayra

    2017-07-01

    Interstitial lung disease (ILD) is a severe rheumatoid arthritis (RA) manifestation. The worst survival has been associated with usual interstitial pneumonia (UIP) definitive pattern in high-resolution chest tomography (HRCT) scans. Moreover, the use of methotrexate in RA-ILD is controversial. Our aim was to evaluate prognostic factors including methotrexate in an RA-ILD cohort and their association with survival. RA-ILD patients referred for medical evaluation and treatment at a single center were included. At the baseline, pulmonary function tests were carried out and a HRCT was obtained. A radiologist evaluated the ILD tomographic pattern and the extent of lung disease. Patients were considered as receiving methotrexate therapy if this drug was specifically prescribed for the treatment of RA-ILD at the beginning of follow up. Seventy-eight patients were included. UIP definite pattern in HRCT was not associated to worse survival. Variables associated with mortality reflected the severity of lung disease. Treatment with methotrexate was associated with survival (HR 0.13, 95% CI 0.02-0.64); older patients had worse prognosis (HR 1.04, 95% CI 1.003-1.09). After adjusting for confounding variables, methotrexate was strongly associated with survival. Methotrexate treatment during follow up was associated with survival. The severity of lung disease and not the tomographic pattern is associated with mortality; older patients had worse prognosis.

  7. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source

    PubMed Central

    Atwood, Robert C.; Bodey, Andrew J.; Price, Stephen W. T.; Basham, Mark; Drakopoulos, Michael

    2015-01-01

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an ‘orthogonal’ fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and ‘facility-independent’: it can run on standard cluster infrastructure at any institution. PMID:25939626

  8. Tomographic inversion of satellite photometry. II

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.; Hays, P. B.; Abreu, V. J.

    1985-01-01

    A method for combining nadir observations of emission features in the upper atmosphere with the result of a tomographic inversion of limb brightness measurements is presented. Simulated and actual results are provided, and error sensitivity is investigated.

  9. Economic Evaluation of Computerized Structural Analysis

    NASA Technical Reports Server (NTRS)

    Fortin, P. E.

    1985-01-01

    This completed effort involved a technical and economic study of the capabilities of computer programs in the area of structural analysis. The applicability of the programs to NASA projects and to other users was studied. The applications in other industries was explored including both research and development and applied areas. The costs of several alternative analysis programs were compared. A literature search covered applicable technical literature including journals, trade publications and books. In addition to the literature search, several commercial companies that have developed computerized structural analysis programs were contacted and their technical brochures reviewed. These programs include SDRC I-DEAS, MSC/NASTRAN, SCADA, SUPERSAP, NISA/DISPLAY, STAAD-III, MICAS, GTSTRUDL, and STARS. These programs were briefly reviewed as applicable to NASA projects.

  10. Remote sensing inputs to National Model Implementation Program for water resources quality improvement

    NASA Technical Reports Server (NTRS)

    Eidenshink, J. C.; Schmer, F. A.

    1979-01-01

    The Lake Herman watershed in southeastern South Dakota has been selected as one of seven water resources systems in the United States for involvement in the National Model Implementation Program (MIP). MIP is a pilot program initiated to illustrate the effectiveness of existing water resources quality improvement programs. The Remote Sensing Institute (RSI) at South Dakota State University has produced a computerized geographic information system for the Lake Herman watershed. All components necessary for the monitoring and evaluation process were included in the data base. The computerized data were used to produce thematic maps and tabular data for the land cover and soil classes within the watershed. These data are being utilized operationally by SCS resource personnel for planning and management purposes.

  11. Realistic prediction of individual facial emotion expressions for craniofacial surgery simulations

    NASA Astrophysics Data System (ADS)

    Gladilin, Evgeny; Zachow, Stefan; Deuflhard, Peter; Hege, Hans-Christian

    2003-05-01

    In addition to the static soft tissue prediction, the estimation of individual facial emotion expressions is an important criterion for the evaluation of the carniofacial surgery planning. In this paper, we present an approach for the estimation of individual facial emotion expressions on the basis of geometrical models of human anatomy derived from tomographic data and the finite element modeling of facial tissue biomechanics.

  12. Computer-based, personalized cognitive training versus classical computer games: a randomized double-blind prospective trial of cognitive stimulation.

    PubMed

    Peretz, Chava; Korczyn, Amos D; Shatil, Evelyn; Aharonson, Vered; Birnboim, Smadar; Giladi, Nir

    2011-01-01

    Many studies have suggested that cognitive training can result in cognitive gains in healthy older adults. We investigated whether personalized computerized cognitive training provides greater benefits than those obtained by playing conventional computer games. This was a randomized double-blind interventional study. Self-referred healthy older adults (n = 155, 68 ± 7 years old) were assigned to either a personalized, computerized cognitive training or to a computer games group. Cognitive performance was assessed at baseline and after 3 months by a neuropsychological assessment battery. Differences in cognitive performance scores between and within groups were evaluated using mixed effects models in 2 approaches: adherence only (AO; n = 121) and intention to treat (ITT; n = 155). Both groups improved in cognitive performance. The improvement in the personalized cognitive training group was significant (p < 0.03, AO and ITT approaches) in all 8 cognitive domains. However, in the computer games group it was significant (p < 0.05) in only 4 (AO) or 6 domains (ITT). In the AO analysis, personalized cognitive training was significantly more effective than playing games in improving visuospatial working memory (p = 0.0001), visuospatial learning (p = 0.0012) and focused attention (p = 0.0019). Personalized, computerized cognitive training appears to be more effective than computer games in improving cognitive performance in healthy older adults. Further studies are needed to evaluate the ecological validity of these findings. Copyright © 2011 S. Karger AG, Basel.

  13. Melanoma Is Skin Deep: A 3D Reconstruction Technique for Computerized Dermoscopic Skin Lesion Classification

    PubMed Central

    Satheesha, T. Y.; Prasad, M. N. Giri; Dhruve, Kashyap D.

    2017-01-01

    Melanoma mortality rates are the highest amongst skin cancer patients. Melanoma is life threating when it grows beyond the dermis of the skin. Hence, depth is an important factor to diagnose melanoma. This paper introduces a non-invasive computerized dermoscopy system that considers the estimated depth of skin lesions for diagnosis. A 3-D skin lesion reconstruction technique using the estimated depth obtained from regular dermoscopic images is presented. On basis of the 3-D reconstruction, depth and 3-D shape features are extracted. In addition to 3-D features, regular color, texture, and 2-D shape features are also extracted. Feature extraction is critical to achieve accurate results. Apart from melanoma, in-situ melanoma the proposed system is designed to diagnose basal cell carcinoma, blue nevus, dermatofibroma, haemangioma, seborrhoeic keratosis, and normal mole lesions. For experimental evaluations, the PH2, ISIC: Melanoma Project, and ATLAS dermoscopy data sets is considered. Different feature set combinations is considered and performance is evaluated. Significant performance improvement is reported the post inclusion of estimated depth and 3-D features. The good classification scores of sensitivity = 96%, specificity = 97% on PH2 data set and sensitivity = 98%, specificity = 99% on the ATLAS data set is achieved. Experiments conducted to estimate tumor depth from 3-D lesion reconstruction is presented. Experimental results achieved prove that the proposed computerized dermoscopy system is efficient and can be used to diagnose varied skin lesion dermoscopy images. PMID:28512610

  14. Assessment of Pharmacy Information System Performance in Three Hospitals in Eastern Province, Saudi Arabia

    PubMed Central

    El.Mahalli, Azza; El-Khafif, Sahar H.; Yamani, Wid

    2016-01-01

    The pharmacy information system is one of the central pillars of a hospital information system. This research evaluated a pharmacy information system according to six aspects of the medication process in three hospitals in Eastern Province, Saudi Arabia. System administrators were interviewed to determine availability of functionalities. Then, system users within the hospital were targeted to evaluate their level of usage of these functionalities. The study was cross-sectional. Two structured surveys were designed. The overall response rate of hospital users was 31.7 percent. In all three hospitals studied, the electronic health record is hybrid, implementation has been completed and the system is running, and the systems have computerized provider order entry and clinical decision support. Also, the pharmacy information systems are integrated with the electronic health record, and computerized provider order entry and almost all prescribing and transcription functionalities are available; however, drug dispensing is a mostly manual process. However, the study hospitals do not use barcode-assisted medication administration systems to verify patient identity and electronically check dose administration, and none of them have computerized adverse drug event monitoring that uses the electronic health record. The numbers of users who used different functionalities most or all of the time was generally low. The highest frequency of utilization was for patient administration records (56.8 percent), and the lowest was for linkage of the pharmacy information system to pharmacy stock (9.1 percent). Encouraging users to use different functionalities was highly recommended. PMID:26903780

  15. Assessment of Pharmacy Information System Performance in Three Hospitals in Eastern Province, Saudi Arabia.

    PubMed

    El Mahalli, Azza; El-Khafif, Sahar H; Yamani, Wid

    2016-01-01

    The pharmacy information system is one of the central pillars of a hospital information system. This research evaluated a pharmacy information system according to six aspects of the medication process in three hospitals in Eastern Province, Saudi Arabia. System administrators were interviewed to determine availability of functionalities. Then, system users within the hospital were targeted to evaluate their level of usage of these functionalities. The study was cross-sectional. Two structured surveys were designed. The overall response rate of hospital users was 31.7 percent. In all three hospitals studied, the electronic health record is hybrid, implementation has been completed and the system is running, and the systems have computerized provider order entry and clinical decision support. Also, the pharmacy information systems are integrated with the electronic health record, and computerized provider order entry and almost all prescribing and transcription functionalities are available; however, drug dispensing is a mostly manual process. However, the study hospitals do not use barcode-assisted medication administration systems to verify patient identity and electronically check dose administration, and none of them have computerized adverse drug event monitoring that uses the electronic health record. The numbers of users who used different functionalities most or all of the time was generally low. The highest frequency of utilization was for patient administration records (56.8 percent), and the lowest was for linkage of the pharmacy information system to pharmacy stock (9.1 percent). Encouraging users to use different functionalities was highly recommended.

  16. Computerized wheeze detection in young infants: comparison of signals from tracheal and chest wall sensors.

    PubMed

    Puder, Lia C; Wilitzki, Silke; Bührer, Christoph; Fischer, Hendrik S; Schmalisch, Gerd

    2016-12-01

    Computerized wheeze detection is an established method for objective assessment of respiratory sounds. In infants, this method has been used to detect subclinical airway obstruction and to monitor treatment effects. The optimal location for the acoustic sensors, however, is unknown. The aim of this study was to evaluate the quality of respiratory sound recordings in young infants, and to determine whether the position of the sensor affected computerized wheeze detection. Respiratory sounds were recorded over the left lateral chest wall and the trachea in 112 sleeping infants (median postmenstrual age: 49 weeks) on 129 test occasions using an automatic wheeze detection device (PulmoTrack ® ). Each recording lasted 10 min and the recordings were stored. A trained clinician retrospectively evaluated the recordings to determine sound quality and disturbances. The wheeze rates of all undisturbed tracheal and chest wall signals were compared using Bland-Altman plots. Comparison of wheeze rates measured over the trachea and the chest wall indicated strong correlation (r  ⩾  0.93, p  <  0.001), with a bias of 1% or less and limits of agreement of within 3% for the inspiratory wheeze rate and within 6% for the expiratory wheeze rate. However, sounds from the chest wall were more often affected by disturbances than sounds from the trachea (23% versus 6%, p  <  0.001). The study suggests that in young infants, a better quality of lung sound recordings can be obtained with the tracheal sensor.

  17. Evaluation and implementation of chemotherapy regimen validation in an electronic health record.

    PubMed

    Diaz, Amber H; Bubalo, Joseph S

    2014-12-01

    Computerized provider order entry of chemotherapy regimens is quickly becoming the standard for prescribing chemotherapy in both inpatient and ambulatory settings. One of the difficulties with implementation of chemotherapy regimen computerized provider order entry lies in verifying the accuracy and completeness of all regimens built in the system library. Our goal was to develop, implement, and evaluate a process for validating chemotherapy regimens in an electronic health record. We describe our experience developing and implementing a process for validating chemotherapy regimens in the setting of a standard, commercially available computerized provider order entry system. The pilot project focused on validating chemotherapy regimens in the adult inpatient oncology setting and adult ambulatory hematologic malignancy setting. A chemotherapy regimen validation process was defined as a result of the pilot project. Over a 27-week pilot period, 32 chemotherapy regimens were validated using the process we developed. Results of the study suggest that by validating chemotherapy regimens, the amount of time spent by pharmacists in daily chemotherapy review was decreased. In addition, the number of pharmacist modifications required to make regimens complete and accurate were decreased. Both physician and pharmacy disciplines showed improved satisfaction and confidence levels with chemotherapy regimens after implementation of the validation system. Chemotherapy regimen validation required a considerable amount of planning and time but resulted in increased pharmacist efficiency and improved provider confidence and satisfaction. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Student Monitoring in Distance Education.

    ERIC Educational Resources Information Center

    Holt, Peter; And Others

    1987-01-01

    Reviews a computerized monitoring system for distance education students at Athabasca University designed to solve the problems of tracking student performance. A pilot project for tutors is described which includes an electronic conferencing system and electronic mail, and an evaluation currently in progress is briefly discussed. (LRW)

  19. Advanced prediction technique for the low speed aerodynamics of V/STOL aircraft. Volume 1: Technical discussion

    NASA Technical Reports Server (NTRS)

    Beatty, T. D.; Worthey, M. K.

    1984-01-01

    The V/STOL Aircraft Propulsive Effects (VAPE) computerized prediction method is evaluated. The program analyzes viscous effects, various jet, inlet, and Short TakeOff and Landing (STOL) models, and examines the aerodynamic configurations of V/STOL aircraft.

  20. Usability Evaluation at the Point-of-Care: A Method to Identify User Information Needs in CPOE Applications

    PubMed Central

    Washburn, Jeff; Fiol, Guilherme Del; Rocha, Roberto A.

    2006-01-01

    Point of care usability evaluation may help identify information needs that occur during the process of providing care. We describe the process of using usability-specific recording software to record Computerized Physician Order Entry (CPOE) ordering sessions on admitted adult and pediatric patients at two urban tertiary hospitals in the Intermountain Healthcare system of hospitals. PMID:17238756

  1. Evaluating the Comparability of Paper-and-Pencil and Computerized Versions of a Large-Scale Certification Test. Research Report. ETS RR-05-21

    ERIC Educational Resources Information Center

    Puhan, Gautam; Boughton, Keith A.; Kim, Sooyeon

    2005-01-01

    The study evaluated the comparability of two versions of a teacher certification test: a paper-and-pencil test (PPT) and computer-based test (CBT). Standardized mean difference (SMD) and differential item functioning (DIF) analyses were used as measures of comparability at the test and item levels, respectively. Results indicated that effect sizes…

  2. Effects of Methylphenidate and Bupropion on DHEA-S and Cortisol Plasma Levels in Attention-Deficit Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Lee, Moon-Soo; Yang, Jae-Won; Ko, Young-Hoon; Han, Changsu; Kim, Seung-Hyun; Lee, Min-Soo; Joe, Sook-Haeng; Jung, In-Kwa

    2008-01-01

    We evaluated plasma levels of DHEA-S and cortisol before and after treating ADHD patients with one of two medications: methylphenidate (n = 12) or bupropion (n = 10). Boys with ADHD (combined type) were evaluated with the Korean ADHD rating scale (K-ARS) and the computerized ADHD diagnostic system (ADS). All assessments were measured at baseline…

  3. Efficient control schemes with limited computation complexity for Tomographic AO systems on VLTs and ELTs

    NASA Astrophysics Data System (ADS)

    Petit, C.; Le Louarn, M.; Fusco, T.; Madec, P.-Y.

    2011-09-01

    Various tomographic control solutions have been proposed during the last decades to ensure efficient or even optimal closed-loop correction to tomographic Adaptive Optics (AO) concepts such as Laser Tomographic AO (LTAO), Multi-Conjugate AO (MCAO). The optimal solution, based on Linear Quadratic Gaussian (LQG) approach, as well as suboptimal but efficient solutions such as Pseudo-Open Loop Control (POLC) require multiple Matrix Vector Multiplications (MVM). Disregarding their respective performance, these efficient control solutions thus exhibit strong increase of on-line complexity and their implementation may become difficult in demanding cases. Among them, two cases are of particular interest. First, the system Real-Time Computer architecture and implementation is derived from past or present solutions and does not support multiple MVM. This is the case of the AO Facility which RTC architecture is derived from the SPARTA platform and inherits its simple MVM architecture, which does not fit with LTAO control solutions for instance. Second, considering future systems such as Extremely Large Telescopes, the number of degrees of freedom is twenty to one hundred times bigger than present systems. In these conditions, tomographic control solutions can hardly be used in their standard form and optimized implementation shall be considered. Single MVM tomographic control solutions represent a potential solution, and straightforward solutions such as Virtual Deformable Mirrors have been already proposed for LTAO but with tuning issues. We investigate in this paper the possibility to derive from tomographic control solutions, such as POLC or LQG, simplified control solutions ensuring simple MVM architecture and that could be thus implemented on nowadays systems or future complex systems. We theoretically derive various solutions and analyze their respective performance on various systems thanks to numerical simulation. We discuss the optimization of their performance and stability issues with respect to classic control solutions. We finally discuss off-line computation and implementation constraints.

  4. Redesign of a computerized clinical reminder for colorectal cancer screening: a human-computer interaction evaluation

    PubMed Central

    2011-01-01

    Background Based on barriers to the use of computerized clinical decision support (CDS) learned in an earlier field study, we prototyped design enhancements to the Veterans Health Administration's (VHA's) colorectal cancer (CRC) screening clinical reminder to compare against the VHA's current CRC reminder. Methods In a controlled simulation experiment, 12 primary care providers (PCPs) used prototypes of the current and redesigned CRC screening reminder in a within-subject comparison. Quantitative measurements were based on a usability survey, workload assessment instrument, and workflow integration survey. We also collected qualitative data on both designs. Results Design enhancements to the VHA's existing CRC screening clinical reminder positively impacted aspects of usability and workflow integration but not workload. The qualitative analysis revealed broad support across participants for the design enhancements with specific suggestions for improving the reminder further. Conclusions This study demonstrates the value of a human-computer interaction evaluation in informing the redesign of information tools to foster uptake, integration into workflow, and use in clinical practice. PMID:22126324

  5. Evaluation of a computerized aid for creating human behavioral representations of human-computer interaction.

    PubMed

    Williams, Kent E; Voigt, Jeffrey R

    2004-01-01

    The research reported herein presents the results of an empirical evaluation that focused on the accuracy and reliability of cognitive models created using a computerized tool: the cognitive analysis tool for human-computer interaction (CAT-HCI). A sample of participants, expert in interacting with a newly developed tactical display for the U.S. Army's Bradley Fighting Vehicle, individually modeled their knowledge of 4 specific tasks employing the CAT-HCI tool. Measures of the accuracy and consistency of task models created by these task domain experts using the tool were compared with task models created by a double expert. The findings indicated a high degree of consistency and accuracy between the different "single experts" in the task domain in terms of the resultant models generated using the tool. Actual or potential applications of this research include assessing human-computer interaction complexity, determining the productivity of human-computer interfaces, and analyzing an interface design to determine whether methods can be automated.

  6. A Computerized Asthma Outcomes Measure Is Feasible for Disease Management.

    PubMed

    Turner-Bowker, Diane M; Saris-Baglama, Renee N; Anatchkova, Milena; Mosen, David M

    2010-04-01

    OBJECTIVE: To develop and test an online assessment referred to as the ASTHMA-CAT (computerized adaptive testing), a patient-based asthma impact, control, and generic health-related quality of life (HRQOL) measure. STUDY DESIGN: Cross-sectional pilot study of the ASTHMA-CAT's administrative feasibility in a disease management population. METHODS: The ASTHMA-CAT included a dynamic or static Asthma Impact Survey (AIS), Asthma Control Test, and SF-8 Health Survey. A sample of clinician-diagnosed adult asthmatic patients (N = 114) completed the ASTHMA-CAT. Results were used to evaluate administrative feasibility of the instrument and psychometric performance of the dynamic AIS relative to the static AIS. A prototype aggregate (group-level) report was developed and reviewed by care providers. RESULTS: Online administration of the ASTHMA-CAT was feasible for patients in disease management. The dynamic AIS functioned well compared with the static AIS in preliminary studies evaluating response burden, precision, and validity. Providers found reports to be relevant, useful, and applicable for care management. CONCLUSION: The ASTHMA-CAT may facilitate asthma care management.

  7. Computerized adaptive control weld skate with CCTV weld guidance project

    NASA Technical Reports Server (NTRS)

    Wall, W. A.

    1976-01-01

    This report summarizes progress of the automatic computerized weld skate development portion of the Computerized Weld Skate with Closed Circuit Television (CCTV) Arc Guidance Project. The main goal of the project is to develop an automatic welding skate demonstration model equipped with CCTV weld guidance. The three main goals of the overall project are to: (1) develop a demonstration model computerized weld skate system, (2) develop a demonstration model automatic CCTV guidance system, and (3) integrate the two systems into a demonstration model of computerized weld skate with CCTV weld guidance for welding contoured parts.

  8. Assessing the resolution-dependent utility of tomograms for geostatistics

    USGS Publications Warehouse

    Day-Lewis, F. D.; Lane, J.W.

    2004-01-01

    Geophysical tomograms are used increasingly as auxiliary data for geostatistical modeling of aquifer and reservoir properties. The correlation between tomographic estimates and hydrogeologic properties is commonly based on laboratory measurements, co-located measurements at boreholes, or petrophysical models. The inferred correlation is assumed uniform throughout the interwell region; however, tomographic resolution varies spatially due to acquisition geometry, regularization, data error, and the physics underlying the geophysical measurements. Blurring and inversion artifacts are expected in regions traversed by few or only low-angle raypaths. In the context of radar traveltime tomography, we derive analytical models for (1) the variance of tomographic estimates, (2) the spatially variable correlation with a hydrologic parameter of interest, and (3) the spatial covariance of tomographic estimates. Synthetic examples demonstrate that tomograms of qualitative value may have limited utility for geostatistics; moreover, the imprint of regularization may preclude inference of meaningful spatial statistics from tomograms.

  9. Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls

    PubMed Central

    Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James

    2013-01-01

    Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972

  10. Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method

    PubMed Central

    Pereira, N F; Sitek, A

    2011-01-01

    Tomographic reconstruction on an irregular grid may be superior to reconstruction on a regular grid. This is achieved through an appropriate choice of the image space model, the selection of an optimal set of points and the use of any available prior information during the reconstruction process. Accordingly, a number of reconstruction-related parameters must be optimized for best performance. In this work, a 3D point cloud tetrahedral mesh reconstruction method is evaluated for quantitative tasks. A linear image model is employed to obtain the reconstruction system matrix and five point generation strategies are studied. The evaluation is performed using the recovery coefficient, as well as voxel- and template-based estimates of bias and variance measures, computed over specific regions in the reconstructed image. A similar analysis is performed for regular grid reconstructions that use voxel basis functions. The maximum likelihood expectation maximization reconstruction algorithm is used. For the tetrahedral reconstructions, of the five point generation methods that are evaluated, three use image priors. For evaluation purposes, an object consisting of overlapping spheres with varying activity is simulated. The exact parallel projection data of this object are obtained analytically using a parallel projector, and multiple Poisson noise realizations of these exact data are generated and reconstructed using the different point generation strategies. The unconstrained nature of point placement in some of the irregular mesh-based reconstruction strategies has superior activity recovery for small, low-contrast image regions. The results show that, with an appropriately generated set of mesh points, the irregular grid reconstruction methods can out-perform reconstructions on a regular grid for mathematical phantoms, in terms of the performance measures evaluated. PMID:20736496

  11. Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method

    NASA Astrophysics Data System (ADS)

    Pereira, N. F.; Sitek, A.

    2010-09-01

    Tomographic reconstruction on an irregular grid may be superior to reconstruction on a regular grid. This is achieved through an appropriate choice of the image space model, the selection of an optimal set of points and the use of any available prior information during the reconstruction process. Accordingly, a number of reconstruction-related parameters must be optimized for best performance. In this work, a 3D point cloud tetrahedral mesh reconstruction method is evaluated for quantitative tasks. A linear image model is employed to obtain the reconstruction system matrix and five point generation strategies are studied. The evaluation is performed using the recovery coefficient, as well as voxel- and template-based estimates of bias and variance measures, computed over specific regions in the reconstructed image. A similar analysis is performed for regular grid reconstructions that use voxel basis functions. The maximum likelihood expectation maximization reconstruction algorithm is used. For the tetrahedral reconstructions, of the five point generation methods that are evaluated, three use image priors. For evaluation purposes, an object consisting of overlapping spheres with varying activity is simulated. The exact parallel projection data of this object are obtained analytically using a parallel projector, and multiple Poisson noise realizations of these exact data are generated and reconstructed using the different point generation strategies. The unconstrained nature of point placement in some of the irregular mesh-based reconstruction strategies has superior activity recovery for small, low-contrast image regions. The results show that, with an appropriately generated set of mesh points, the irregular grid reconstruction methods can out-perform reconstructions on a regular grid for mathematical phantoms, in terms of the performance measures evaluated.

  12. An Application of Computerized Axial Tomography (CAT) Technology to Mass Raid Tracking

    DTIC Science & Technology

    1989-08-01

    ESD-TR-89-305 MTR-10542 An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking By John K. Barr August 1989...NO 11. TITLE (Include Security Classification) An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking 12...by block number) Computerized Axial Tomography ( CAT ) Scanner Electronic Support Measures (ESM) Fusion (continued) 19. ABSTRACT (Continue on

  13. Increasing profitability through computerization.

    PubMed

    Sokol, D J

    1988-01-01

    The author explores the pragmatic or financial justification for computerizing a dental practice and discusses a computerized approach to precollection and collection for the dental office. The article also deals with the use of computerized correspondence to augment the recall policy of the office and to help generate new patient referrals and discusses the pros and cons of utilizing a dental computer service bureau in implementing these policies.

  14. Influence of the limited detector size on spatial variations of the reconstruction accuracy in holographic tomography

    NASA Astrophysics Data System (ADS)

    Kostencka, Julianna; Kozacki, Tomasz; Hennelly, Bryan; Sheridan, John T.

    2017-06-01

    Holographic tomography (HT) allows noninvasive, quantitative, 3D imaging of transparent microobjects, such as living biological cells and fiber optics elements. The technique is based on acquisition of multiple scattered fields for various sample perspectives using digital holographic microscopy. Then, the captured data is processed with one of the tomographic reconstruction algorithms, which enables 3D reconstruction of refractive index distribution. In our recent works we addressed the issue of spatially variant accuracy of the HT reconstructions, which results from the insufficient model of diffraction that is applied in the widely-used tomographic reconstruction algorithms basing on the Rytov approximation. In the present study, we continue investigating the spatially variant properties of the HT imaging, however, we are now focusing on the limited spatial size of holograms as a source of this problem. Using the Wigner distribution representation and the Ewald sphere approach, we show that the limited size of the holograms results in a decreased quality of tomographic imaging in off-center regions of the HT reconstructions. This is because the finite detector extent becomes a limiting aperture that prohibits acquisition of full information about diffracted fields coming from the out-of-focus structures of a sample. The incompleteness of the data results in an effective truncation of the tomographic transfer function for the out-of-center regions of the tomographic image. In this paper, the described effect is quantitatively characterized for three types of the tomographic systems: the configuration with 1) object rotation, 2) scanning of the illumination direction, 3) the hybrid HT solution combing both previous approaches.

  15. Intensity-enhanced MART for tomographic PIV

    NASA Astrophysics Data System (ADS)

    Wang, HongPing; Gao, Qi; Wei, RunJie; Wang, JinJun

    2016-05-01

    A novel technique to shrink the elongated particles and suppress the ghost particles in particle reconstruction of tomographic particle image velocimetry is presented. This method, named as intensity-enhanced multiplicative algebraic reconstruction technique (IntE-MART), utilizes an inverse diffusion function and an intensity suppressing factor to improve the quality of particle reconstruction and consequently the precision of velocimetry. A numerical assessment about vortex ring motion with and without image noise is performed to evaluate the new algorithm in terms of reconstruction, particle elongation and velocimetry. The simulation is performed at seven different seeding densities. The comparison of spatial filter MART and IntE-MART on the probability density function of particle peak intensity suggests that one of the local minima of the distribution can be used to separate the ghosts and actual particles. Thus, ghost removal based on IntE-MART is also introduced. To verify the application of IntE-MART, a real plate turbulent boundary layer experiment is performed. The result indicates that ghost reduction can increase the accuracy of RMS of velocity field.

  16. Utilization of Oleogels as a Replacement for Solid Fat in Aerated Baked Goods: Physicochemical, Rheological, and Tomographic Characterization.

    PubMed

    Kim, Joo Young; Lim, Jeongtaek; Lee, JaeHwan; Hwang, Hong-Sik; Lee, Suyong

    2017-02-01

    Canola oil-carnauba wax oleogels were evaluated as a replacement for shortening in a baked cake system. The use of oleogels produced cake batters with a lower pseudoplastic property and also contributed to their viscous nature. The shortening replacement with oleogels at up to 50% was effective in maintaining the ability to hold air cells into the cake batters. The volume of cakes had an overall tendency to decrease with increasing shortening replacement with oleogels, leading to increased cake firmness. The tomographic analysis demonstrated that the total porosity and fragmentation index were reduced in the oleogel cakes, showing a more connected solid structure. The levels of saturated fatty acids in the cakes containing oleogels were significantly reduced to 13.3%, compared to the control with shortening (74.2%). As a result, the use of oleogels for shortening up to 25% produced cakes with lower levels of saturated fatty acids without quality loss. © 2016 Institute of Food Technologists®.

  17. The effect of partial rostral hemimandibulectomy on mandibular mobility and temporomandibular joint morphology in the dog.

    PubMed

    Umphlet, R C; Johnson, A L; Eurell, J C; Losonsky, J

    1988-01-01

    Partial rostral hemimandibulectomy was performed in 10 adult dogs. The temporomandibular joints (TMJs) were examined radiographically and tomographically before surgery, and mandibular stability was evaluated before and immediately after surgery. Radiographic, tomographic, and hemimandibular mobility assessments were made again at months 3 and 6. The TMJs were examined grossly and histologically in five dogs euthanatized at month 3 and in five dogs euthanatized at month 6. Statistically significant hemimandibular instability (p less than 0.05) persisted in all subjects throughout the study. The radiographic appearance of the joints remained unaltered; however, space asymmetry was identified in postoperative tomograms of three dogs at month 3 and four dogs at month 6. The TMJs were grossly normal at necropsy. Histologically, there were degenerative changes in articular cartilage and subchondral bone in all of the joints. The authors conclude that partial rostral hemimandibulectomy causes TMJ degeneration, as a consequence of hemimandibular instability or abnormal loading, or both.

  18. Resting-state functional connectivity assessed with two diffuse optical tomographic systems.

    PubMed

    Niu, Haijing; Khadka, Sabin; Tian, Fenghua; Lin, Zi-Jing; Lu, Chunming; Zhu, Chaozhe; Liu, Hanli

    2011-04-01

    Functional near-infrared spectroscopy (fNIRS) is recently utilized as a new approach to assess resting-state functional connectivity (RSFC) in the human brain. For any new technique or new methodology, it is necessary to be able to replicate similar experiments using different instruments in order to establish its liability and reproducibility. We apply two different diffuse optical tomographic (DOT) systems (i.e., DYNOT and CW5), with various probe arrangements to evaluate RSFC in the sensorimotor cortex by utilizing a previously published experimental protocol and seed-based correlation analysis. Our results exhibit similar spatial patterns and strengths in RSFC between the bilateral motor cortexes. The consistent observations are obtained from both DYNOT and CW5 systems, and are also in good agreement with the previous fNIRS study. Overall, we demonstrate that the fNIRS-based RSFC is reproducible by various DOT imaging systems among different research groups, enhancing the confidence of neuroscience researchers and clinicians to utilize fNIRS for future applications.

  19. Phase decomposition and ordering in Ni-11.3 at.% Ti studied with atom probe tomography.

    PubMed

    Al-Kassab, T; Kompatscher, M; Kirchheim, R; Kostorz, G; Schönfeld, B

    2014-09-01

    The decomposition behavior of Ni-rich Ni-Ti was reassessed using Tomographic Atom Probe (TAP) and Laser Assisted Wide Angle Tomographic Atom Probe. Single crystalline specimens of Ni-11.3 at.% Ti were investigated, the states selected from the decomposition path were the metastable γ″ and γ' states introduced on the basis of small-angle neutron scattering (SANS) and the two-phase model for evaluation. The composition values of the precipitates in these states could not be confirmed by APT data as the interface of the ordered precipitates may not be neglected. The present results rather suggest to apply a three-phase model for the interpretation of SANS measurements, in which the width of the interface remains nearly unchanged and the L12 structure close to 3:1 stoichiometry is maintained in the core of the precipitates from the γ″ to the γ' state. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Measuring value for money: a scoping review on economic evaluation of health information systems.

    PubMed

    Bassi, Jesdeep; Lau, Francis

    2013-01-01

    To explore how key components of economic evaluations have been included in evaluations of health information systems (HIS), to determine the state of knowledge on value for money for HIS, and provide guidance for future evaluations. We searched databases, previously collected papers, and references for relevant papers published from January 2000 to June 2012. For selection, papers had to: be a primary study; involve a computerized system for health information processing, decision support, or management reporting; and include an economic evaluation. Data on study design and economic evaluation methods were extracted and analyzed. Forty-two papers were selected and 33 were deemed high quality (scores ≥ 8/10) for further analysis. These included 12 economic analyses, five input cost analyses, and 16 cost-related outcome analyses. For HIS types, there were seven primary care electronic medical records, six computerized provider order entry systems, five medication management systems, five immunization information systems, four institutional information systems, three disease management systems, two clinical documentation systems, and one health information exchange network. In terms of value for money, 23 papers reported positive findings, eight were inconclusive, and two were negative. We found a wide range of economic evaluation papers that were based on different assumptions, methods, and metrics. There is some evidence of value for money in selected healthcare organizations and HIS types. However, caution is needed when generalizing these findings. Better reporting of economic evaluation studies is needed to compare findings and build on the existing evidence base we identified.

  1. Detection of Acute and Long-Term Effects of Concussion: Dual-Task Gait Balance Control Versus Computerized Neurocognitive Test.

    PubMed

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2018-02-16

    To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits alone. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Identifying design considerations for a shared decision aid for use at the point of outpatient clinical care: An ethnographic study at an inner city clinic.

    PubMed

    Hajizadeh, Negin; Perez Figueroa, Rafael E; Uhler, Lauren M; Chiou, Erin; Perchonok, Jennifer E; Montague, Enid

    2013-03-06

    Computerized decision aids could facilitate shared decision-making at the point of outpatient clinical care. The objective of this study was to investigate whether a computerized shared decision aid would be feasible to implement in an inner-city clinic by evaluating the current practices in shared decision-making, clinicians' use of computers, patient and clinicians' attitudes and beliefs toward computerized decision aids, and the influence of time on shared decision-making. Qualitative data analysis of observations and semi-structured interviews with patients and clinicians at an inner-city outpatient clinic. The findings provided an exploratory look at the prevalence of shared decision-making and attitudes about health information technology and decision aids. A prominent barrier to clinicians engaging in shared decision-making was a lack of perceived patient understanding of medical information. Some patients preferred their clinicians make recommendations for them rather than engage in formal shared decision-making. Health information technology was an integral part of the clinic visit and welcomed by most clinicians and patients. Some patients expressed the desire to engage with health information technology such as viewing their medical information on the computer screen with their clinicians. All participants were receptive to the idea of a decision aid integrated within the clinic visit although some clinicians were concerned about the accuracy of prognostic estimates for complex medical problems. We identified several important considerations for the design and implementation of a computerized decision aid including opportunities to: bridge clinician-patient communication about medical information while taking into account individual patients' decision-making preferences, complement expert clinician judgment with prognostic estimates, take advantage of patient waiting times, and make tasks involved during the clinic visit more efficient. These findings should be incorporated into the design and implementation of a computerized shared decision aid at an inner-city hospital.

  3. Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.

    PubMed

    Honaker, Julie A; Shepard, Neil T

    2011-01-01

    Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.

  4. Influence of computerized sounding out on spelling performance for children who do and do not rely on AAC.

    PubMed

    McCarthy, Jillian H; Hogan, Tiffany P; Beukelman, David R; Schwarz, Ilsa E

    2015-05-01

    Spelling is an important skill for individuals who rely on augmentative and alternative communication (AAC). The purpose of this study was to investigate how computerized sounding out influenced spelling accuracy of pseudo-words. Computerized sounding out was defined as a word elongated, thus providing an opportunity for a child to hear all the sounds in the word at a slower rate. Seven children with cerebral palsy, four who use AAC and three who do not, participated in a single subject AB design. The results of the study indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words produced by participants. The study provides preliminary evidence for the use of computerized sounding out during spelling tasks for children with cerebral palsy who do and do not use AAC. Future directions and clinical implications are discussed. We investigated how computerized sounding out influenced spelling accuracy of pseudowords for children with complex communication needs who did and did not use augmentative and alternative communication (AAC). Results indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words by participants, suggesting that computerized sounding out might assist in more accurate spelling for children who use AAC. Future research is needed to determine how language and reading abilities influence the use of computerized sounding out with children who have a range of speech intelligibility abilities and do and do not use AAC.

  5. Associations Between Collateral Status and Thrombus Characteristics and Their Impact in Anterior Circulation Stroke.

    PubMed

    Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M

    2018-02-01

    Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.

  6. Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery

    PubMed Central

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209

  7. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    PubMed

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.

  8. Postural Control in Children with Autism.

    ERIC Educational Resources Information Center

    Kohen-Raz, Reuven; And Others

    1992-01-01

    Postural control was evaluated in 91 autistic, 166 normal, and 18 mentally retarded children using a computerized posturographic procedure. In comparison to normal children, the autistic subjects were less likely to exhibit age-related changes in postural performance, and postures were more variable and less stable. (Author/JDD)

  9. Computerized Online Bibliographic Searching. SPEC Kit #154.

    ERIC Educational Resources Information Center

    Hocker, Susan

    For this kit, 106 Association of Research Libraries (ARL) academic libraries were surveyed concerning: (1) current administration/organization; (2) evaluation; (3) patron relations; (4) services; and (5) the impact of online searching on collections. Responses were received from 83 libraries, many of which contributed sample materials. Analyses of…

  10. I.T.S. camera deployment and systems integration P.I.N. 4ITV.09.121 : evaluation

    DOT National Transportation Integrated Search

    2006-08-01

    The Monroe County Department of Transportation (MCDOT) has built upon the success of its first computerized traffic signal system. The system has been operational since 1985. In the late 1990s the Department initiated a project to integrate Intell...

  11. The Impact of Goal Setting on Team Simulation Experience.

    ERIC Educational Resources Information Center

    Fandt, Patricia M.; And Others

    1990-01-01

    Describes a study that examined the effects of goal setting on undergraduate students competing in a computerized business simulation. Group cohesiveness is discussed, treatments for the experimental and control groups are described, perceived team success is measured, and team simulation performance is evaluated. (30 references) (LRW)

  12. Contemporary computerized methods for logging planning

    Treesearch

    Chris B. LeDoux

    1988-01-01

    Contemporary harvest planning graphic software is highlighted with practical applications. Planning results from a production study of the Clearwater Cable Yarder are summarized. Application of the planning methods to evaluation of proposed silvicultural treatments is included. Results show that 3-dimensional graphic analysis of proposed harvesting or silvicultural...

  13. Use of Microcomputer to Manage Assessment Data.

    ERIC Educational Resources Information Center

    Vance, Booney; Hayden, David

    1982-01-01

    Examples are provided of a computerized special education management system used to manage assessment data for exceptional students. The system is designed to provide a simple yet efficient method of tracking data from educational and psychological evaluations (specifically the Wechsler Intelligence Scale for Children--Revised scores). (CL)

  14. Item Analysis in Introductory Economics Testing.

    ERIC Educational Resources Information Center

    Tinari, Frank D.

    1979-01-01

    Computerized analysis of multiple choice test items is explained. Examples of item analysis applications in the introductory economics course are discussed with respect to three objectives: to evaluate learning; to improve test items; and to help improve classroom instruction. Problems, costs and benefits of the procedures are identified. (JMD)

  15. Computerized Manufacturing Automation: Employment, Education, and the Workplace.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Office of Technology Assessment.

    This report describes the technologies of programmable automation (PA) in manufacturing, their uses, and future capabilities. Following the summary and introduction, the prospects for PA are examined from several perspectives. Chapter 3 defines PA technologies, describes their developmental trends, and evaluates the potential for the integration…

  16. Towards computerizing intensive care sedation guidelines: design of a rule-based architecture for automated execution of clinical guidelines

    PubMed Central

    2010-01-01

    Background Computerized ICUs rely on software services to convey the medical condition of their patients as well as assisting the staff in taking treatment decisions. Such services are useful for following clinical guidelines quickly and accurately. However, the development of services is often time-consuming and error-prone. Consequently, many care-related activities are still conducted based on manually constructed guidelines. These are often ambiguous, which leads to unnecessary variations in treatments and costs. The goal of this paper is to present a semi-automatic verification and translation framework capable of turning manually constructed diagrams into ready-to-use programs. This framework combines the strengths of the manual and service-oriented approaches while decreasing their disadvantages. The aim is to close the gap in communication between the IT and the medical domain. This leads to a less time-consuming and error-prone development phase and a shorter clinical evaluation phase. Methods A framework is proposed that semi-automatically translates a clinical guideline, expressed as an XML-based flow chart, into a Drools Rule Flow by employing semantic technologies such as ontologies and SWRL. An overview of the architecture is given and all the technology choices are thoroughly motivated. Finally, it is shown how this framework can be integrated into a service-oriented architecture (SOA). Results The applicability of the Drools Rule language to express clinical guidelines is evaluated by translating an example guideline, namely the sedation protocol used for the anaesthetization of patients, to a Drools Rule Flow and executing and deploying this Rule-based application as a part of a SOA. The results show that the performance of Drools is comparable to other technologies such as Web Services and increases with the number of decision nodes present in the Rule Flow. Most delays are introduced by loading the Rule Flows. Conclusions The framework is an effective solution for computerizing clinical guidelines as it allows for quick development, evaluation and human-readable visualization of the Rules and has a good performance. By monitoring the parameters of the patient to automatically detect exceptional situations and problems and by notifying the medical staff of tasks that need to be performed, the computerized sedation guideline improves the execution of the guideline. PMID:20082700

  17. Towards computerizing intensive care sedation guidelines: design of a rule-based architecture for automated execution of clinical guidelines.

    PubMed

    Ongenae, Femke; De Backere, Femke; Steurbaut, Kristof; Colpaert, Kirsten; Kerckhove, Wannes; Decruyenaere, Johan; De Turck, Filip

    2010-01-18

    Computerized ICUs rely on software services to convey the medical condition of their patients as well as assisting the staff in taking treatment decisions. Such services are useful for following clinical guidelines quickly and accurately. However, the development of services is often time-consuming and error-prone. Consequently, many care-related activities are still conducted based on manually constructed guidelines. These are often ambiguous, which leads to unnecessary variations in treatments and costs.The goal of this paper is to present a semi-automatic verification and translation framework capable of turning manually constructed diagrams into ready-to-use programs. This framework combines the strengths of the manual and service-oriented approaches while decreasing their disadvantages. The aim is to close the gap in communication between the IT and the medical domain. This leads to a less time-consuming and error-prone development phase and a shorter clinical evaluation phase. A framework is proposed that semi-automatically translates a clinical guideline, expressed as an XML-based flow chart, into a Drools Rule Flow by employing semantic technologies such as ontologies and SWRL. An overview of the architecture is given and all the technology choices are thoroughly motivated. Finally, it is shown how this framework can be integrated into a service-oriented architecture (SOA). The applicability of the Drools Rule language to express clinical guidelines is evaluated by translating an example guideline, namely the sedation protocol used for the anaesthetization of patients, to a Drools Rule Flow and executing and deploying this Rule-based application as a part of a SOA. The results show that the performance of Drools is comparable to other technologies such as Web Services and increases with the number of decision nodes present in the Rule Flow. Most delays are introduced by loading the Rule Flows. The framework is an effective solution for computerizing clinical guidelines as it allows for quick development, evaluation and human-readable visualization of the Rules and has a good performance. By monitoring the parameters of the patient to automatically detect exceptional situations and problems and by notifying the medical staff of tasks that need to be performed, the computerized sedation guideline improves the execution of the guideline.

  18. Automated Computerized Analysis of Speechin Psychiatric Disorders

    PubMed Central

    Cohen, Alex S.; Elvevåg, Brita

    2014-01-01

    Purpose of Review Disturbances in communication are a hallmark of severe mental illnesses. Recent technological advances have paved the way for objectifying communication using automated computerized linguistic and acoustic analysis. We review recent studies applying various computer-based assessments to the natural language produced by adult patients with severe mental illness. Recent Findings Automated computerized methods afford tools with which it is possible to objectively evaluate patients in a reliable, valid and efficient manner that complements human ratings. Crucially, these measures correlate with important clinical measures. The clinical relevance of these novel metrics has been demonstrated by showing their relationship to functional outcome measures, their in vivo link to classic ‘language’ regions in the brain, and, in the case of linguistic analysis, their relationship to candidate genes for severe mental illness. Summary Computer based assessments of natural language afford a framework with which to measure communication disturbances in adults with SMI. Emerging evidence suggests that they can be reliable and valid, and overcome many practical limitations of more traditional assessment methods. The advancement of these technologies offers unprecedented potential for measuring and understanding some of the most crippling symptoms of some of the most debilitating illnesses known to humankind. PMID:24613984

  19. TOmographic Remote Observer of Ionospheric Disturbances

    DTIC Science & Technology

    2007-11-15

    ionosphere . The proposed spacecraft was an evolutionary design from the USUSat, Combat Sentinel, and USUSat II programs whose histories are shown in...Figure 1. The primary science instrument, TOROID for TOmographic Remote Observer of Ionospheric Disturbances, is a photometer for measuring the

  20. Acoustic representation of tomographic data

    NASA Astrophysics Data System (ADS)

    Wampler, Cheryl; Zahrt, John D.; Hotchkiss, Robert S.; Zahrt, Rebecca; Kust, Mark

    1993-04-01

    Tomographic data and tomographic reconstructions are naturally periodic in the angle of rotation of the turntable and the polar angel of the coordinates in the object, respectively. Similarly, acoustic waves are periodic and have amplitude and wavelength as free parameters that can be fit to another representation. Work has been in progress for some time in bringing the acoustic senses to bear on large data sets rather than just the visual sense. We will provide several different acoustic representations of both raw data and density maps. Rather than graphical portrayal of the data and reconstructions, you will be presented various 'tone poems.'

  1. Optical tomograph optimized for tumor detection inside highly absorbent organs

    NASA Astrophysics Data System (ADS)

    Boutet, Jérôme; Koenig, Anne; Hervé, Lionel; Berger, Michel; Dinten, Jean-Marc; Josserand, Véronique; Coll, Jean-Luc

    2011-05-01

    This paper presents a tomograph for small animal fluorescence imaging. The compact and cost-effective system described in this article was designed to address the problem of tumor detection inside highly absorbent heterogeneous organs, such as lungs. To validate the tomograph's ability to detect cancerous nodules inside lungs, in vivo tumor growth was studied on seven cancerous mice bearing murine mammary tumors marked with Alexa Fluor 700. They were successively imaged 10, 12, and 14 days after the primary tumor implantation. The fluorescence maps were compared over this time period. As expected, the reconstructed fluorescence increases with the tumor growth stage.

  2. Lamb wave tomographic imaging system for aircraft structural health assessment

    NASA Astrophysics Data System (ADS)

    Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.

    1999-01-01

    A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.

  3. Sodankylä ionospheric tomography dataset 2003-2014

    NASA Astrophysics Data System (ADS)

    Norberg, J.; Roininen, L.; Kero, A.; Raita, T.; Ulich, T.; Markkanen, M.; Juusola, L.; Kauristie, K.

    2015-12-01

    Sodankylä Geophysical Observatory has been operating a tomographic receiver network and collecting the produced data since 2003. The collected dataset consists of phase difference curves measured from Russian COSMOS dual-frequency (150/400 MHz) low-Earth-orbit satellite signals, and tomographic electron density reconstructions obtained from these measurements. In this study vertical total electron content (VTEC) values are integrated from the reconstructed electron densities to make a qualitative and quantitative analysis to validate the long-term performance of the tomographic system. During the observation period, 2003-2014, there were three-to-five operational stations at the Fenno-Scandinavian sector. Altogether the analysis consists of around 66 000 overflights, but to ensure the quality of the reconstructions, the examination is limited to cases with descending (north to south) overflights and maximum elevation over 60°. These constraints limit the number of overflights to around 10 000. Based on this dataset, one solar cycle of ionospheric vertical total electron content estimates is constructed. The measurements are compared against International Reference Ionosphere IRI-2012 model, F10.7 solar flux index and sunspot number data. Qualitatively the tomographic VTEC estimate corresponds to reference data very well, but the IRI-2012 model are on average 40 % higher of that of the tomographic results.

  4. Selecting and Evaluating Software for Use in a Preschool Classroom: From the Young Child's and Researcher's Perspective.

    ERIC Educational Resources Information Center

    Vartuli, Sue; And Others

    A 16-item evaluation form is presented to aid in selection of appropriate computerized game materials for preschool children. The form was derived from a 32-week-long study involving 66 children 3, 4, and 5 years of age who were allowed to play computer games during free play or work time while attending a modified Montessori preschool program. In…

  5. Computerized planimetry evaluation of hyperbaric oxygen therapy in the treatment of diabetic foot.

    PubMed

    Kawecki, Marek; Pasek, Jarosław; Cieślar, Grzegorz; Sieroń, Aleksander; Knefel, Grzegorz; Nowak, Mariusz; Glik, Justyna

    2018-01-01

    Diabetic foot ulcer is one of the major complications of diabetes mellitus in adults. The aim of the study was to conduct a planimetry evaluation of the effectiveness of hyperbaric oxygen therapy (HBOT) in the treatment of patients with vascular disorders caused by diabetic foot. The study included 94 patients, 30 females (32%) and 64 males (68%), aged 33-76 years, with diabetes lasting 1.5-32 years, who underwent HBOT due to diabetic foot. All patients from that group underwent vascular procedures prior to HBOT. In qualifying patients for hyperbaric oxygen therapy, transcutaneous oximetry method was applied (30-60 exposures in hyperbaric oxygen at pressure of 2.5 ATA). Progress in wound healing was evaluated by computerized planimetry system IRIS 4. In 26 patients the wounds were completely closed and in 37 patients the topical state was significantly improved - the wound surface decreased by 34% in average. During the treatment, in 11 patients amputation of fingers and metatarsal necrotic bones was performed, while in 9 patients amputation was prevented. A planimetry evaluation showed that the application of HBOT in the treatment of diabetic foot enhances foot ulcer healing, reduces tissue damage, contributes to the reduction of complications related to soft tissue and bone infections.

  6. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    NASA Astrophysics Data System (ADS)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.

  7. Cardiac metastases of Ewing sarcoma detected by 18F-FDG PET/CT.

    PubMed

    Coccia, Paola; Ruggiero, Antonio; Rufini, Vittoria; Maurizi, Palma; Attinà, Giorgio; Marano, Riccardo; Natale, Luigi; Leccisotti, Lucia; Calcagni, Maria L; Riccardi, Riccardo

    2012-04-01

    Positron emission tomography (PET) is widely used in the diagnostic evaluation and staging of different malignant tumors. The role of PET/computed tomographic scan in detecting distant metastases in the workup of Ewing sarcoma in children or young adults is less well defined. We report a case of a boy affected by a metastatic Ewing sarcoma with cardiac asymptomatic metastasis detected by F-FDG PET/computed tomography.

  8. Computed tomographic identification of calcified optic nerve drusen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez, H.; Blatt, E.S.; Hibri, N.S.

    1983-07-01

    Four cases of optic disk drusen were accurately diagnosed with orbital computed tomography (CT). The radiologist should be aware of the characteristic CT finding of discrete calcification within an otherwise normal optic disk. This benign process is easily differentiated from lesions such as calcific neoplastic processes of the posterior globe. CT identification of optic disk drusen is essential in the evaluation of visual field defects, migraine-like headaches, and pseudopapilledema.

  9. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...

  10. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...

  11. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...

  12. Microcomputer Network for Computerized Adaptive Testing (CAT)

    DTIC Science & Technology

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  13. Computerized Adaptive Testing (CAT): A User Manual

    DTIC Science & Technology

    1984-03-12

    NPRDC TR 84-32 COMPUTERIZED ADAPTIVE TESTING ( CAT ): A USER MANUAL Susan Hardwick Lawrence Eastman Ross Cooper Rehab Group, Incorporated San...a ~EI’IOD COVIRED COMPUTERIZED ADAPTIVE TESTING ( CAT ) Final Report Aug 1981-June 1982 A USER MANUAL 1. ~l:l’t,ORMINCI ORCI. RE~ORT NUM.I:R 62-83...II nee• .. _, entl ldentll)’ ,,. llloclr _,.,) A joint-service effort is underway to develop a computerized adaptive testing ( CAT ) system and to

  14. Evaluation of computed tomography numbers for treatment planning of lung cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mira, J.G.; Fullerton, G.D.; Ezekiel, J.

    1982-09-01

    Computerized tomography numbers (CTN) were evaluated in 32 computerized tomography scans performed on patients with carcinoma of the lung, with the aim of evaluating CTN in normal (lung, blood, muscle, etc) and pathologic tissues (tumor, atelectasis, effusion, post-radiation fibrosis). Our main findings are: 1. Large individual CTN variations are encountered in both normal and pathologic tissues, above and below mean values. Hence, absolute numbers are meaningless. Measurements of any abnormal intrathoracic structure should be compared in relation to normal tissue CTN values in the same scan. 2. Tumor and complete atelectasis have CTN basically similar to soft tissue. Hence, thesemore » numbers are not useful for differential diagnosis. 3. Effusions usually have lower CTN and can be distinguished from previous situations. 4. Dosimetry based on uniform lung density assumptions (i.e., 300 mg/cm/sup 3/) might produce substantial dose errors as lung CTN exhibit variations indicating densities well above and below this value. 5. Preliminary information indicates that partial atelectasis and incipient post-radiation fibrosis can have very low CTN. Hence, they can be differentiated from solid tumors in certain cases, and help in differential diagnosis of post radiation recurrence within the radiotherapy field versus fibrosis.« less

  15. The Naval Enlisted Professional Development Information System (NEPDIS): Front End Analysis (FEA) Process. Technical Report 159.

    ERIC Educational Resources Information Center

    Aagard, James A.; Ansbro, Thomas M.

    The Naval Enlisted Professional Development Information System (NEPDIS) was designed to function as a fully computerized information assembly and analysis system to support labor force, personnel, and training management. The NEPDIS comprises separate training development, instructional, training record and evaluation, career development, and…

  16. Computerized Testing in a Hospital Setting: Psychometric and Psychological Effects.

    ERIC Educational Resources Information Center

    Peterson, Leif; And Others

    1996-01-01

    This Swedish study sought to evaluate a touch-screen computer-based (CB) test administration system in a hospital setting in comparison with paper-and-pencil administrative routine. Patients were given psychometric tests (involving depression, mood, and intelligence measurement) in both formats. Patient pleasantness, activation, and calmness were…

  17. Ability Level Estimation of Students on Probability Unit via Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Özyurt, Hacer; Özyurt, Özcan

    2015-01-01

    Problem Statement: Learning-teaching activities bring along the need to determine whether they achieve their goals. Thus, multiple choice tests addressing the same set of questions to all are frequently used. However, this traditional assessment and evaluation form contrasts with modern education, where individual learning characteristics are…

  18. JPRS Report, Science & Technology, Europe, EC Commissioners Evaluate Electronics, Computer Industries

    DTIC Science & Technology

    1991-06-14

    American firms of foreign origin as regards R&TD is being practised by the Department of Defense, and Sematech is one example here. As negotiations... taxation measures. Training schemes for staff in the banking sector encom- passing both the financial side and computerized sys- tems applications

  19. Computerization of School Administration: Impact on the Principal's Role--A Case Study.

    ERIC Educational Resources Information Center

    Telem, Moshe

    2001-01-01

    Describes a study at an Israeli high school that investigated changes in the principal's role as the result of the introduction of a school management information system (SMIS). Discusses information handling and flow, interrelations with teachers, accountability, instruction evaluation, supervision, feedback, frequency of meetings, and shared…

  20. Evaluation of the CATSIB DIF Procedure in a Pretest Setting

    ERIC Educational Resources Information Center

    Nandakumar, Ratna; Roussos, Louis

    2004-01-01

    A new procedure, CATSIB, for assessing differential item functioning (DIF) on computerized adaptive tests (CATs) is proposed. CATSIB, a modified SIBTEST procedure, matches test takers on estimated ability and controls for impact-induced Type 1 error inflation by employing a CAT version of the IBTEST "regression correction." The…

  1. Development and Evaluation of a Computerized Engagement Intervention for IPS Supported Employment

    ERIC Educational Resources Information Center

    Haslett, William R.

    2013-01-01

    Background: Current information technology offers the promise of innovative approaches to engagement for mental health. Specific psychosocial services may also benefit from technology-based engagement interventions. Individual Placement and Support (IPS) is an evidence-based service that helps people who have a severe mental illness to gain…

  2. A Comparison Study of Item Exposure Control Strategies in MCAT

    ERIC Educational Resources Information Center

    Mao, Xiuzhen; Ozdemir, Burhanettin; Wang, Yating; Xiu, Tao

    2016-01-01

    Four item selection indexes with and without exposure control are evaluated and compared in multidimensional computerized adaptive testing (CAT). The four item selection indices are D-optimality, Posterior expectation Kullback-Leibler information (KLP), the minimized error variance of the linear combination score with equal weight (V1), and the…

  3. Guide to the Use of Information. Question Negotiation, Search Delivery, Search Evaluation.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Education, Topeka.

    This guide to the use of information reviews the development of Kansas Project Communicate from 1972-1976, and the Kansas State Department of Education (KSDE) computerized information service (KEDDS), which serves as the resource component of the information dissemination system. KEDDS (Kansas Educational Dissemination Diffusion system) is…

  4. Topographic Brain Mapping: A Window on Brain Function?

    ERIC Educational Resources Information Center

    Karniski, Walt M.

    1989-01-01

    The article reviews the method of topographic mapping of the brain's electrical activity. Multiple electroencephalogram (EEG) electrodes and computerized analysis of the EEG signal are used to generate maps of frequency and voltage (evoked potential). This relatively new technique holds promise in the evaluation of children with behavioral and…

  5. A Comparative Evaluation of Computer Based and Non-Computer Based Instructional Strategies.

    ERIC Educational Resources Information Center

    Emerson, Ian

    1988-01-01

    Compares the computer assisted instruction (CAI) tutorial with its non-computerized pedagogical roots: the Socratic Dialog with Skinner's Programmed Instruction. Tests the effectiveness of a CAI tutorial on diffusion and osmosis against four other interactive and non-interactive instructional strategies. Notes computer based strategies were…

  6. Optical analysis of crystal growth

    NASA Technical Reports Server (NTRS)

    Workman, Gary L.; Passeur, Andrea; Harper, Sabrina

    1994-01-01

    Processing and data reduction of holographic images from Spacelab presents some interesting challenges in determining the effects of microgravity on crystal growth processes. Evaluation of several processing techniques, including the Computerized Holographic Image Processing System and the image processing software ITEX150, will provide fundamental information for holographic analysis of the space flight data.

  7. Cambridge Crystallographic Data Centre. II. Structural Data File

    ERIC Educational Resources Information Center

    Allen, F. H.; And Others

    1973-01-01

    The Cambridge Crystallographic Data Centre is concerned with the retrieval, evaluation, synthesis, and dissemination of structural data obtained by diffraction methods. This article (Part I is EJ053033) describes the work of the center and deals with the organization and maintenance of a computerized file of numeric crystallographic structural…

  8. Self-Report Measures of Juvenile Psychopathic Personality Traits: A Comparative Review

    ERIC Educational Resources Information Center

    Vaughn, Michael G.; Howard, Matthew O.

    2005-01-01

    The authors evaluated self-report instruments currently being used to assess children and adolescents with psychopathic personality traits with respect to their reliability, validity, and research utility. Comprehensive searches across multiple computerized bibliographic databases were conducted and supplemented with manual searches. A total of 30…

  9. Tomographic Image Compression Using Multidimensional Transforms.

    ERIC Educational Resources Information Center

    Villasenor, John D.

    1994-01-01

    Describes a method for compressing tomographic images obtained using Positron Emission Tomography (PET) and Magnetic Resonance (MR) by applying transform compression using all available dimensions. This takes maximum advantage of redundancy of the data, allowing significant increases in compression efficiency and performance. (13 references) (KRN)

  10. Towards a framework for developing semantic relatedness reference standards.

    PubMed

    Pakhomov, Serguei V S; Pedersen, Ted; McInnes, Bridget; Melton, Genevieve B; Ruggieri, Alexander; Chute, Christopher G

    2011-04-01

    Our objective is to develop a framework for creating reference standards for functional testing of computerized measures of semantic relatedness. Currently, research on computerized approaches to semantic relatedness between biomedical concepts relies on reference standards created for specific purposes using a variety of methods for their analysis. In most cases, these reference standards are not publicly available and the published information provided in manuscripts that evaluate computerized semantic relatedness measurement approaches is not sufficient to reproduce the results. Our proposed framework is based on the experiences of medical informatics and computational linguistics communities and addresses practical and theoretical issues with creating reference standards for semantic relatedness. We demonstrate the use of the framework on a pilot set of 101 medical term pairs rated for semantic relatedness by 13 medical coding experts. While the reliability of this particular reference standard is in the "moderate" range; we show that using clustering and factor analyses offers a data-driven approach to finding systematic differences among raters and identifying groups of potential outliers. We test two ontology-based measures of relatedness and provide both the reference standard containing individual ratings and the R program used to analyze the ratings as open-source. Currently, these resources are intended to be used to reproduce and compare results of studies involving computerized measures of semantic relatedness. Our framework may be extended to the development of reference standards in other research areas in medical informatics including automatic classification, information retrieval from medical records and vocabulary/ontology development. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. “Computerized Counseling Reduces HIV-1 Viral Load and Sexual Transmission Risk: Findings from a Randomized Controlled Trial”

    PubMed Central

    KURTH, Ann E.; SPIELBERG, Freya; CLELAND, Charles M.; LAMBDIN, Barrot; BANGSBERG, David R.; FRICK, Pamela A.; SEVERYNEN, Anneleen O.; CLAUSEN, Marc; NORMAN, Robert G.; LOCKHART, David; SIMONI, Jane M.; HOLMES, King K.

    2014-01-01

    Objective Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Design Longitudinal RCT. Settings An academic HIV clinic and a community-based organization in Seattle. Subjects 240 HIV-positive adults on ART; 209 completed nine-month follow-up (87% retention). Intervention Randomization to computerized counseling or assessment-only, 4 sessions over 9 months. Main Outcome Measures HIV-1 viral suppression, and self-reported ART adherence, and transmission risks, compared using generalized estimating equations. Results Overall, intervention participants had reduced viral load (VL): mean 0.17 log10 decline, versus 0.13 increase in controls, p = 0.053, and significant difference in ART adherence baseline to 9 months (p = 0.046). Their sexual transmission risk behaviors decreased (OR = 0.55, p = 0.020), a reduction not seen among controls (OR = 1.1, p = 0.664), and a significant difference in change (p = 0.040). Intervention effect was driven by those most in need: among those with detectable virus at baseline (>30 copies/milliliter, n=89), intervention effect was mean 0.60 log10 VL decline versus 0.15 increase in controls, p=0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, p = 0.038. Conclusions Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior. PMID:24384803

  12. Neurosurgery simulation in residency training: feasibility, cost, and educational benefit.

    PubMed

    Gasco, Jaime; Holbrook, Thomas J; Patel, Achal; Smith, Adrian; Paulson, David; Muns, Alan; Desai, Sohum; Moisi, Marc; Kuo, Yong-Fan; Macdonald, Bart; Ortega-Barnett, Juan; Patterson, Joel T

    2013-10-01

    The effort required to introduce simulation in neurosurgery academic programs and the benefits perceived by residents have not been systematically assessed. To create a neurosurgery simulation curriculum encompassing basic and advanced skills, cadaveric dissection, cranial and spine surgery simulation, and endovascular and computerized haptic training. A curriculum with 68 core exercises per academic year was distributed in individualized sets of 30 simulations to 6 neurosurgery residents. The total number of procedures completed during the academic year was set to 180. The curriculum includes 79 simulations with physical models, 57 cadaver dissections, and 44 haptic/computerized sessions. Likert-type evaluations regarding self-perceived performance were completed after each exercise. Subject identification was blinded to junior (postgraduate years 1-3) or senior resident (postgraduate years 4-6). Wilcoxon rank testing was used to detect differences within and between groups. One hundred eighty procedures and surveys were analyzed. Junior residents reported proficiency improvements in 82% of simulations performed (P < .001). Senior residents reported improvement in 42.5% of simulations (P < .001). Cadaver simulations accrued the highest reported benefit (71.5%; P < .001), followed by physical simulators (63.8%; P < .001) and haptic/computerized (59.1; P < .001). Initial cost is $341,978.00, with $27,876.36 for annual operational expenses. The systematic implementation of a simulation curriculum in a neurosurgery training program is feasible, is favorably regarded, and has a positive impact on trainees of all levels, particularly in junior years. All simulation forms, cadaver, physical, and haptic/computerized, have a role in different stages of learning and should be considered in the development of an educational simulation program.

  13. Evaluation of interactive computerized training to teach parents to implement photographic activity schedules with children with autism spectrum disorder.

    PubMed

    Gerencser, Kristina R; Higbee, Thomas S; Akers, Jessica S; Contreras, Bethany P

    2017-07-01

    Training parents of children with autism spectrum disorder can be a challenge due to limited resources, time, and money. Interactive computerized training (ICT)-a self-paced program that incorporates instructions, videos, and interactive questions-is one method professionals can use to disseminate trainings to broader populations. This study extends previous research on ICT by assessing the effect of ICT to teach three parents how to implement a photographic activity schedule using a systematic prompting procedure with their child. Following ICT, all parents increased their fidelity to implementation of an activity schedule during role-play sessions with an adult. Fidelity remained high during implementation with their child and maintained during a 2-week follow-up. © 2017 Society for the Experimental Analysis of Behavior.

  14. Computerized content analysis of some adolescent writings of Napoleon Bonaparte: a test of the validity of the method.

    PubMed

    Gottschalk, Louis A; DeFrancisco, Don; Bechtel, Robert J

    2002-08-01

    The aim of this study was to test the validity of a computer software program previously demonstrated to be capable of making DSM-IV neuropsychiatric diagnoses from the content analysis of speech or verbal texts. In this report, the computer program was applied to three personal writings of Napoleon Bonaparte when he was 12 to 16 years of age. The accuracy of the neuropsychiatric evaluations derived from the computerized content analysis of these writings of Napoleon was independently corroborated by two biographers who have described pertinent details concerning his life situations, moods, and other emotional reactions during this adolescent period of his life. The relevance of this type of computer technology to psychohistorical research and clinical psychiatry is suggested.

  15. Visualization techniques for tongue analysis in traditional Chinese medicine

    NASA Astrophysics Data System (ADS)

    Pham, Binh L.; Cai, Yang

    2004-05-01

    Visual inspection of the tongue has been an important diagnostic method of Traditional Chinese Medicine (TCM). Clinic data have shown significant connections between various viscera cancers and abnormalities in the tongue and the tongue coating. Visual inspection of the tongue is simple and inexpensive, but the current practice in TCM is mainly experience-based and the quality of the visual inspection varies between individuals. The computerized inspection method provides quantitative models to evaluate color, texture and surface features on the tongue. In this paper, we investigate visualization techniques and processes to allow interactive data analysis with the aim to merge computerized measurements with human expert's diagnostic variables based on five-scale diagnostic conditions: Healthy (H), History Cancers (HC), History of Polyps (HP), Polyps (P) and Colon Cancer (C).

  16. Preliminary performance estimates of a highly maneuverable remotely piloted vehicle. [computerized synthesis program to assess effects of vehicle and mission parameters

    NASA Technical Reports Server (NTRS)

    Nelms, W. P., Jr.; Axelson, J. A.

    1974-01-01

    A computerized synthesis program has been used to assess the effects of various vehicle and mission parameters on the performance of a highly maneuverable remotely piloted vehicle (RPV) for the air-to-air combat role. The configuration used in the study is a trapezoidal-wing and body concept, with forward-mounted stabilizing and control surfaces. The study mission consists of an outbound cruise, an acceleration phase, a series of subsonic and supersonic turns, and a return cruise. Performance is evaluated in terms of both the required vehicle weight to accomplish this mission and combat effectiveness as measured by turning and acceleration capability. The report describes the synthesis program, the mission, the vehicle, and the results of sensitivity and trade studies.

  17. Quantification of osteolytic bone lesions in a preclinical rat trial

    NASA Astrophysics Data System (ADS)

    Fränzle, Andrea; Bretschi, Maren; Bäuerle, Tobias; Giske, Kristina; Hillengass, Jens; Bendl, Rolf

    2013-10-01

    In breast cancer, most of the patients who died, have developed bone metastasis as disease progression. Bone metastases in case of breast cancer are mainly bone destructive (osteolytic). To understand pathogenesis and to analyse response to different treatments, animal models, in our case rats, are examined. For assessment of treatment response to bone remodelling therapies exact segmentations of osteolytic lesions are needed. Manual segmentations are not only time-consuming but lack in reproducibility. Computerized segmentation tools are essential. In this paper we present an approach for the computerized quantification of osteolytic lesion volumes using a comparison to a healthy reference model. The presented qualitative and quantitative evaluation of the reconstructed bone volumes show, that the automatically segmented lesion volumes complete missing bone in a reasonable way.

  18. Resources for Improving Computerized Learning Environments.

    ERIC Educational Resources Information Center

    Yeaman, Andrew R. J.

    1989-01-01

    Presents an annotated review of human factors literature that discusses computerized environments. Topics discussed include the application of office automation practices to educational environments; video display terminal (VDT) workstations; health and safety hazards; planning educational facilities; ergonomics in computerized offices; and…

  19. An overview of selected information storage and retrieval issues in computerized document processing

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Ihebuzor, Valentine U.

    1984-01-01

    The rapid development of computerized information storage and retrieval techniques has introduced the possibility of extending the word processing concept to document processing. A major advantage of computerized document processing is the relief of the tedious task of manual editing and composition usually encountered by traditional publishers through the immense speed and storage capacity of computers. Furthermore, computerized document processing provides an author with centralized control, the lack of which is a handicap of the traditional publishing operation. A survey of some computerized document processing techniques is presented with emphasis on related information storage and retrieval issues. String matching algorithms are considered central to document information storage and retrieval and are also discussed.

  20. Clinical outcomes after magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) for pulmonary embolism evaluation.

    PubMed

    Repplinger, Michael D; Nagle, Scott K; Harringa, John B; Broman, Aimee T; Lindholm, Christopher R; François, Christopher J; Grist, Thomas M; Reeder, Scott B; Schiebler, Mark L

    2018-05-10

    To compare patient outcomes following magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) ordered for suspected pulmonary embolism (PE). In this IRB-approved, single-center, retrospective, case-control study, we reviewed the medical records of all patients evaluated for PE with MRA during a 5-year period along with age- and sex-matched controls evaluated with CTA. Only the first instance of PE evaluation during the study period was included. After application of our exclusion criteria to both study arms, the analysis included 1173 subjects. The primary endpoint was major adverse PE-related event (MAPE), which we defined as major bleeding, venous thromboembolism, or death during the 6 months following the index imaging test (MRA or CTA), obtained through medical record review. Logistic regression, chi-square test for independence, and Fisher's exact test were used with a p < 0.05 threshold. The overall 6-month MAPE rate following MRA (5.4%) was lower than following CTA (13.6%, p < 0.01). Amongst outpatients, the MAPE rate was lower for MRA (3.7%) than for CTA (8.0%, p = 0.01). Accounting for age, sex, referral source, BMI, and Wells' score, patients were less likely to suffer MAPE than those who underwent CTA, with an odds ratio of 0.44 [0.24, 0.80]. Technical success rate did not differ significantly between MRA (92.6%) and CTA (90.5%) groups (p = 0.41). Within the inherent limitations of a retrospective case-controlled analysis, we observed that the rate of MAPE was lower (more favorable) for patients following pulmonary MRA for the primary evaluation of suspected PE than following CTA.

Top