Sample records for concentric firing system

  1. Experimental research on the infrared gas fire detection system

    NASA Astrophysics Data System (ADS)

    Jiang, Yalong; Liu, Yangyang

    2018-02-01

    Open fires and smoldering fires were differentiated using five experiments: wood pyrolysis, polyurethane smoldering, wood fire, polyurethane fire and cotton rope smoldering. At the same time, the distribution of CO2 and CO concentration in combustion products at different heights was studied. Real fire and environmental interference were distinguished using burning cigarettes and sandalwood. The results showed that open fires and smoldering fires produced significantly different ratios of CO2 and CO concentrations. By judging the order of magnitudes of the ratio CO2 and CO concentrations in the combustion products, open fire and smoldering fire could be effectively distinguished. At the same time, the comparison experiment showed that the rate of increase of the concentration of CO in the smoldering fire was higher than that under non-fire conditions. With the criterion of the rate of increase of CO concentration, smoldering fire and non-fire could be distinguished.

  2. Development of gas fire detection system using tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, Y. L.; Li, G.; Yang, T.; Wang, J. J.

    2017-01-01

    The conventional fire detection methods mainly produce an alarm through detecting the changes in smoke concentration, flame radiation, heat and other physical parameters in the environment, but are unable to provide an early warning of a fire emergency. We have designed a gas fire detection system with a high detection sensitivity and high selectivity using the tunable semiconductor diode laser as a light source and combining wavelength modulation and harmonic detection technology. This system can invert the second harmonic signal obtained to obtain the concentration of carbon monoxide gas (a fire characteristic gas) so as to provide an early warning of fire. We reduce the system offset noise and the background noise generated due to the laser interference by deducting the system background spectrum lines from the second harmonic signal. This can also eliminate the interference of other gas spectral lines to a large extent. We detected the concentration of the carbon monoxide gas generated in smoldering sandalwood fire and open beech wood fire with the homemade fire simulator, and tested the lowest detectable limit of system. The test results show that the lowest detectable limit can reach 5×10-6 the system can maintain stable operation for a long period of time and can automatically trigger a water mist fire extinguishing system, which can fully meet the needs of early fire warning.

  3. Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Greensburg, Paul; McKnight, Robert; Xu, Jennifer C.; Liu, C. C.; Dutta, Prabir; Makel, Darby; Blake, D.; Sue-Antillio, Jill

    2007-01-01

    Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

  4. Characterization of a mine fire using atmospheric monitoring system sensor data.

    PubMed

    Yuan, L; Thomas, R A; Zhou, L

    2017-06-01

    Atmospheric monitoring systems (AMS) have been widely used in underground coal mines in the United States for the detection of fire in the belt entry and the monitoring of other ventilation-related parameters such as airflow velocity and methane concentration in specific mine locations. In addition to an AMS being able to detect a mine fire, the AMS data have the potential to provide fire characteristic information such as fire growth - in terms of heat release rate - and exact fire location. Such information is critical in making decisions regarding fire-fighting strategies, underground personnel evacuation and optimal escape routes. In this study, a methodology was developed to calculate the fire heat release rate using AMS sensor data for carbon monoxide concentration, carbon dioxide concentration and airflow velocity based on the theory of heat and species transfer in ventilation airflow. Full-scale mine fire experiments were then conducted in the Pittsburgh Mining Research Division's Safety Research Coal Mine using an AMS with different fire sources. Sensor data collected from the experiments were used to calculate the heat release rates of the fires using this methodology. The calculated heat release rate was compared with the value determined from the mass loss rate of the combustible material using a digital load cell. The experimental results show that the heat release rate of a mine fire can be calculated using AMS sensor data with reasonable accuracy.

  5. The diversification of Paleozoic fire systems and fluctuations in atmospheric oxygen concentration

    PubMed Central

    Scott, Andrew C.; Glasspool, Ian J.

    2006-01-01

    By comparing Silurian through end Permian [≈250 million years (Myr)] charcoal abundance with contemporaneous macroecological changes in vegetation and climate we aim to demonstrate that long-term variations in fire occurrence and fire system diversification are related to fluctuations in Late Paleozoic atmospheric oxygen concentration. Charcoal, a proxy for fire, occurs in the fossil record from the Late Silurian (≈420 Myr) to the present. Its presence at any interval in the fossil record is already taken to constrain atmospheric oxygen within the range of 13% to 35% (the “fire window”). Herein, we observe that, as predicted, atmospheric oxygen levels rise from ≈13% in the Late Devonian to ≈30% in the Late Permian so, too, fires progressively occur in an increasing diversity of ecosystems. Sequentially, data of note include: the occurrence of charcoal in the Late Silurian/Early Devonian, indicating the burning of a diminutive, dominantly rhyniophytoid vegetation; an apparent paucity of charcoal in the Middle to Late Devonian that coincides with a predicted atmospheric oxygen low; and the subsequent diversification of fire systems throughout the remainder of the Late Paleozoic. First, fires become widespread during the Early Mississippian, they then become commonplace in mire systems in the Middle Mississippian; in the Pennsylvanian they are first recorded in upland settings and finally, based on coal petrology, become extremely important in many Permian mire settings. These trends conform well to changes in atmospheric oxygen concentration, as predicted by modeling, and indicate oxygen levels are a significant control on long-term fire occurrence. PMID:16832054

  6. Characterization of a mine fire using atmospheric monitoring system sensor data

    PubMed Central

    Yuan, L.; Thomas, R.A.; Zhou, L.

    2017-01-01

    Atmospheric monitoring systems (AMS) have been widely used in underground coal mines in the United States for the detection of fire in the belt entry and the monitoring of other ventilation-related parameters such as airflow velocity and methane concentration in specific mine locations. In addition to an AMS being able to detect a mine fire, the AMS data have the potential to provide fire characteristic information such as fire growth — in terms of heat release rate — and exact fire location. Such information is critical in making decisions regarding fire-fighting strategies, underground personnel evacuation and optimal escape routes. In this study, a methodology was developed to calculate the fire heat release rate using AMS sensor data for carbon monoxide concentration, carbon dioxide concentration and airflow velocity based on the theory of heat and species transfer in ventilation airflow. Full-scale mine fire experiments were then conducted in the Pittsburgh Mining Research Division’s Safety Research Coal Mine using an AMS with different fire sources. Sensor data collected from the experiments were used to calculate the heat release rates of the fires using this methodology. The calculated heat release rate was compared with the value determined from the mass loss rate of the combustible material using a digital load cell. The experimental results show that the heat release rate of a mine fire can be calculated using AMS sensor data with reasonable accuracy. PMID:28845058

  7. Fire safety practices in the Shuttle and the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

  8. Lead exposures and biological responses in military weapons systems: Aerosol characteristics and acute lead effects among US Army artillerymen: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharyya, M.H.; Stebbings, J.H.; Peterson, D.P.

    1993-03-01

    This study was to determine the concentration and chemical nature of lead (Pb) aerosols produced during the firing of artillery and to determine the exposures and biological responses of crew members exposed to lead aerosols during such firing. The concentrations of lead-containing aerosols at crew positions depended on wind conditions, with higher concentrations when firing into a head wind. Aerosol concentrations were highest in the muzzle blast zone. Concentrations of lead in the blood of crew members rose during the first 12 days of exposure to elevated airborne lead concentrations and then leveled off. There was no rapid decrease inmore » blood lead concentrations after completion of firing. Small decreases in hematocrit and small increases in free erythrocyte porphyrin were correlated with increasing exposure to airborne lead. These changes were reversed by seven weeks after firing. Changes in nerve conduction velocity had borderline statistical significance to airborne lead exposure. In measuring nerve conduction velocity, differences in skin temperature must be taken into account.« less

  9. [Research on early fire detection with CO-CO2 FTIR-spectroscopy].

    PubMed

    Du, Jian-hua; Zhang, Ren-cheng; Huang, Xiang-ying; Gong, Xue; Zhang, Xiao-hua

    2007-05-01

    A new fire detection method is put forward based on the theory of FTIR spectroscopy through analyzing all kinds of detection methods, in which CO and CO2 are chosen as early fire detection objects, and an early fire experiment system has been set up. The concentration characters of CO and CO2 were obtained through early fire experiments including real alarm sources and nuisance alarm sources. In real alarm sources there are abundant CO and CO2 which change regularly. In nuisance alarm sources there is almost no CO. So it's feasible to reduce the false alarms and increase the sensitivity of early fire detectors through analyzing the concentration characters of CO and CO2.

  10. Relationships among charcoal particles from modern lacustrine sediments and remotely sensed fire events

    NASA Astrophysics Data System (ADS)

    López-Pérez, M.; Correa-Metrio, A.

    2013-05-01

    Analysis of charcoal particles from lacustrine sediments is a useful tool to understand fire regimes through time, and their relationships with climate and vegetation. However, the extent of the relationship between charcoal particles and their origin in terms of the spatial and temporal extent of the fire events is poorly known in the tropics. Modern sediments were collected from lakes in the Yucatan Peninsula and Central Mexico, 51 and 22 lakes respectively, to analyze their charcoal concentration and its relationships with modern fire events. Number of modern fire events was derived from the public source Fire Information for Resource Management System (FIRMS) for concentric spatial rings that ranged from 1 to 30 km of radius. The association between charcoal and fires was evaluated through the construction of linear models to explain charcoal concentration as a function of the number of fires recorded. Additionally, charcoal particles were stratified according to size to determine the association between fire distance and charcoal size classes. The relationship between total charcoal concentration and fire events was stronger for central Mexico than for the Yucatan Peninsula, which is probably the result of differences in vegetation cover. The highest determination coefficients were obtained for charcoal particle sizes ranging between 0.2 and 0.8 mm2, and for fire event distances of between 0 and 15 km from the lake. Overall, the analyses presented here offer useful tools to quantitatively and spatially reconstruct past regional fire dynamics in Central Mexico and the Yucatan Peninsula.

  11. Concentrating Solar Power Projects - Solar Electric Generating Station I |

    Science.gov Websites

    fire in 1999 damaged the storage system and it was not replaced. Status Date: April 14, 2017 Photo with : 3 hour(s) Thermal Storage Description: Storage system was damaged by fire in 1999 and was not

  12. Numerical modelling of the work of a pulsed aerosol system for fire fighting at the ignitions of liquid hydrocarbon fuels

    NASA Astrophysics Data System (ADS)

    Rychkov, A. D.

    2009-06-01

    The work of a pulsed aerosol system for fire fighting is modelled, which is designed for fire fighting at oil storages and at the spills of oil products, whose vapors were modelled by gaseous methane. The system represents a device for separate installation, which consists of a charge of solid propellant (the gas generator) and a container with fine-dispersed powder of the flame-damper substance. The methane combustion was described by a one-stage gross-reaction, the influence of the concentration of vapors of the flame-damper substance on the combustion process was taken into account by reducing the pre-exponent factor in the Arrhenius law and was described by an empirical dependence. The computational experiment showed that the application of the pulsed aerosol system for fire fighting ensures an efficient transport of fine-dispersed aerosol particles of the flame-damping substance and its forming vapors to the combustion zone; the concentration of particles ensures the damping of the heat source.

  13. Impact of forest fires on particulate matter and ozone levels during the 2003, 2004 and 2005 fire seasons in Portugal.

    PubMed

    Martins, V; Miranda, A I; Carvalho, A; Schaap, M; Borrego, C; Sá, E

    2012-01-01

    The main purpose of this work is to estimate the impact of forest fires on air pollution applying the LOTOS-EUROS air quality modeling system in Portugal for three consecutive years, 2003-2005. Forest fire emissions have been included in the modeling system through the development of a numerical module, which takes into account the most suitable parameters for Portuguese forest fire characteristics and the burnt area by large forest fires. To better evaluate the influence of forest fires on air quality the LOTOS-EUROS system has been applied with and without forest fire emissions. Hourly concentration results have been compared to measure data at several monitoring locations with better modeling quality parameters when forest fire emissions were considered. Moreover, hourly estimates, with and without fire emissions, can reach differences in the order of 20%, showing the importance and the influence of this type of emissions on air quality. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Fire investigation

    NASA Astrophysics Data System (ADS)

    Gomberg, A.

    There was considerable progress made on several fronts of fire investigation in the United States in recent years. Progress was made in increasing the quantity of fire investigation and reporting, through efforts to develop the National Fire Incident Reporting System. Improving overall quality of fire investigation is the objective of efforts such as the Fire Investigation Handbook, which was developed and published by the National Bureau of Standards, and the upgrading and expanding of the ""dictionary'' of fire investigation and reporting, the NFPA 901, Uniform Coding for Fire Protection, system. The science of fire investigation as furthered also by new approaches to post fire interviews being developed at the University of Washington, and by in-depth research into factors involved in several large loss fires, including the MGM Grand Hotel in Las Vegas. Finally, the use of special study fire investigations - in-depth investigations concentrating on specific fire problems - is producing new glimpses into the nature of the national fire problem. A brief description of the status of efforts in each of these areas is discussed.

  15. Evaluation of mine fires due to spontaneous combustion in the mechanized faces of Middle Anatolian Lignite mine (OAL), case studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gueyagueler, T.; Karaman, H.

    1995-12-31

    In this paper fires due to spontaneous combustion in Middle Anatolian Lignite mine (OAL) which is the first fully mechanized underground lignite mine in Turkey, are studied. Since the installation of mechanization, due to spontaneous heating, four panel fires namely, AO1, AO2, AO3 and AO4 have broken out. During these fires, the concentrations of carbon monoxide, methane and the velocity of air are measured continuously by the Micro Minos Environmental monitoring system. For each fire, the environment where fire has started is examined and the possible causes of the fire are investigated. Also the precautions taken to extinguish the firemore » at different stages are described and the importance of the early detection of mine fire are discussed together with the limitations of the monitoring system the practical difficulties observed during the fire.« less

  16. Dynamics and Physiological Roles of Stochastic Firing Patterns Near Bifurcation Points

    NASA Astrophysics Data System (ADS)

    Jia, Bing; Gu, Huaguang

    2017-06-01

    Different stochastic neural firing patterns or rhythms that appeared near polarization or depolarization resting states were observed in biological experiments on three nervous systems, and closely matched those simulated near bifurcation points between stable equilibrium point and limit cycle in a theoretical model with noise. The distinct dynamics of spike trains and interspike interval histogram (ISIH) of these stochastic rhythms were identified and found to build a relationship to the coexisting behaviors or fixed firing frequency of four different types of bifurcations. Furthermore, noise evokes coherence resonances near bifurcation points and plays important roles in enhancing information. The stochastic rhythms corresponding to Hopf bifurcation points with fixed firing frequency exhibited stronger coherence degree and a sharper peak in the power spectrum of the spike trains than those corresponding to saddle-node bifurcation points without fixed firing frequency. Moreover, the stochastic firing patterns changed to a depolarization resting state as the extracellular potassium concentration increased for the injured nerve fiber related to pathological pain or static blood pressure level increased for aortic depressor nerve fiber, and firing frequency decreased, which were different from the physiological viewpoint that firing frequency increased with increasing pressure level or potassium concentration. This shows that rhythms or firing patterns can reflect pressure or ion concentration information related to pathological pain information. Our results present the dynamics of stochastic firing patterns near bifurcation points, which are helpful for the identification of both dynamics and physiological roles of complex neural firing patterns or rhythms, and the roles of noise.

  17. Cinema Fire Modelling by FDS

    NASA Astrophysics Data System (ADS)

    Glasa, J.; Valasek, L.; Weisenpacher, P.; Halada, L.

    2013-02-01

    Recent advances in computer fluid dynamics (CFD) and rapid increase of computational power of current computers have led to the development of CFD models capable to describe fire in complex geometries incorporating a wide variety of physical phenomena related to fire. In this paper, we demonstrate the use of Fire Dynamics Simulator (FDS) for cinema fire modelling. FDS is an advanced CFD system intended for simulation of the fire and smoke spread and prediction of thermal flows, toxic substances concentrations and other relevant parameters of fire. The course of fire in a cinema hall is described focusing on related safety risks. Fire properties of flammable materials used in the simulation were determined by laboratory measurements and validated by fire tests and computer simulations

  18. Wild Fire Emissions for the NOAA Operational HYSPLIT Smoke Model

    NASA Astrophysics Data System (ADS)

    Huang, H. C.; ONeill, S. M.; Ruminski, M.; Shafran, P.; McQueen, J.; DiMego, G.; Kondragunta, S.; Gorline, J.; Huang, J. P.; Stunder, B.; Stein, A. F.; Stajner, I.; Upadhayay, S.; Larkin, N. K.

    2015-12-01

    Particulate Matter (PM) generated from forest fires often lead to degraded visibility and unhealthy air quality in nearby and downstream areas. To provide near-real time PM information to the state and local agencies, the NOAA/National Weather Service (NWS) operational HYSPLIT (Hybrid Single Particle Lagrangian Integrated Trajectory Model) smoke modeling system (NWS/HYSPLIT smoke) provides the forecast of smoke concentration resulting from fire emissions driven by the NWS North American Model 12 km weather predictions. The NWS/HYSPLIT smoke incorporates the U.S. Forest Service BlueSky Smoke Modeling Framework (BlueSky) to provide smoke fire emissions along with the input fire locations from the NOAA National Environmental Satellite, Data, and Information Service (NESDIS)'s Hazard Mapping System fire and smoke detection system. Experienced analysts inspect satellite imagery from multiple sensors onboard geostationary and orbital satellites to identify the location, size and duration of smoke emissions for the model. NWS/HYSPLIT smoke is being updated to use a newer version of USFS BlueSky. The updated BlueSky incorporates the Fuel Characteristic Classification System version 2 (FCCS2) over the continental U.S. and Alaska. FCCS2 includes a more detailed description of fuel loadings with additional plant type categories. The updated BlueSky also utilizes an improved fuel consumption model and fire emission production system. For the period of August 2014 and June 2015, NWS/HYSPLIT smoke simulations show that fire smoke emissions with updated BlueSky are stronger than the current operational BlueSky in the Northwest U.S. For the same comparisons, weaker fire smoke emissions from the updated BlueSky were observed over the middle and eastern part of the U.S. A statistical evaluation of NWS/HYSPLIT smoke predicted total column concentration compared to NOAA NESDIS GOES EAST Aerosol Smoke Product retrievals is underway. Preliminary results show that using the newer version of BlueSky leads to improved performance of NWS/HYSPLIT-smoke for June 2015. These results are partially due to the default fuel loading selected for Canadian fires that lead to stronger fire emissions there. The use of more realistic Canadian fuel loading may improve NWS/HYSPLIT smoke forecast.

  19. Modelling threats to water quality from fire suppression chemicals and post-fire erosion

    NASA Astrophysics Data System (ADS)

    Hyde, Kevin; Ziemniak, Chris; Elliot, William; Samuels, William

    2014-05-01

    Misapplication of fire retardant chemicals into streams and rivers may threaten aquatic life. The possible threat depends on the contaminant concentration that, in part, is controlled by dispersion within flowing water. In the event of a misapplication, methods are needed to rapidly estimate the chemical mass entering the waterway and the dispersion and transport within the system. Here we demonstrate a new tool that calculates the chemical mass based on aircraft delivery system, fire chemical type, and stream and intersect geometry. The estimated mass is intended to be transferred into a GIS module that uses real-time stream data to map and simulate the dispersion and transport downstream. This system currently accounts only for aqueous transport. We envision that the GIS module can be modified to incorporate sediment transport, specifically to model movement of sediments from post-fire erosion. This modification could support assessment of threats of post-fire erosion to water quality and water supply systems.

  20. The FireWork air quality forecast system with near-real-time biomass burning emissions: Recent developments and evaluation of performance for the 2015 North American wildfire season.

    PubMed

    Pavlovic, Radenko; Chen, Jack; Anderson, Kerry; Moran, Michael D; Beaulieu, Paul-André; Davignon, Didier; Cousineau, Sophie

    2016-09-01

    Environment and Climate Change Canada's FireWork air quality (AQ) forecast system for North America with near-real-time biomass burning emissions has been running experimentally during the Canadian wildfire season since 2013. The system runs twice per day with model initializations at 00 UTC and 12 UTC, and produces numerical AQ forecast guidance with 48-hr lead time. In this work we describe the FireWork system, which incorporates near-real-time biomass burning emissions based on the Canadian Wildland Fire Information System (CWFIS) as an input to the operational Regional Air Quality Deterministic Prediction System (RAQDPS). To demonstrate the capability of the system we analyzed two forecast periods in 2015 (June 2-July 15, and August 15-31) when fire activity was high, and observed fire-smoke-impacted areas in western Canada and the western United States. Modeled PM2.5 surface concentrations were compared with surface measurements and benchmarked with results from the operational RAQDPS, which did not consider near-real-time biomass burning emissions. Model performance statistics showed that FireWork outperformed RAQDPS with improvements in forecast hourly PM2.5 across the region; the results were especially significant for stations near the path of fire plume trajectories. Although the hourly PM2.5 concentrations predicted by FireWork still displayed bias for areas with active fires for these two periods (mean bias [MB] of -7.3 µg m(-3) and 3.1 µg m(-3)), it showed better forecast skill than the RAQDPS (MB of -11.7 µg m(-3) and -5.8 µg m(-3)) and demonstrated a greater ability to capture temporal variability of episodic PM2.5 events (correlation coefficient values of 0.50 and 0.69 for FireWork compared to 0.03 and 0.11 for RAQDPS). A categorical forecast comparison based on an hourly PM2.5 threshold of 30 µg m(-3) also showed improved scores for probability of detection (POD), critical success index (CSI), and false alarm rate (FAR). Smoke from wildfires can have a large impact on regional air quality (AQ) and can expose populations to elevated pollution levels. Environment and Climate Change Canada has been producing operational air quality forecasts for all of Canada since 2009 and is now working to include near-real-time wildfire emissions (NRTWE) in its operational AQ forecasting system. An experimental forecast system named FireWork, which includes NRTWE, has been undergoing testing and evaluation since 2013. A performance analysis of FireWork forecasts for the 2015 wildfire season shows that FireWork provides significant improvements to surface PM2.5 forecasts and valuable guidance to regional forecasters and first responders.

  1. Wood crib fire free burning test in ISO room

    NASA Astrophysics Data System (ADS)

    Qiang, Xu; Griffin, Greg; Bradbury, Glenn; Dowling, Vince

    2006-04-01

    In the research of application potential of water mist fire suppression system for fire fighting in train luggage carriage, a series of experiments were conducted in ISO room on wood crib fire with and without water mist actuation. The results of free burn test without water mist suppression are used as reference in evaluating the efficiency of water mist suppression system. As part of the free burn test, several tests have been done under the hood of ISO room to calibrate the size of the crib fire and these tests can also be used in analyzing the wall effect in room fire hazard. In these free burning experiments, wood cribs of four sizes under the hood were tested. The temperature of crib fire, heat flux around the fire, gas concentration in hood of ISO room were measured in the experiments and two sets of thermal imaging system were used to get the temperature distribution and the typical shape of the free burning flames. From the experiments, the radiation intensity in specific positions around the fire, the effective heat of combustion, mass loss, oxygen consumption rate for different sizes of fire, typical structure of the flame and self extinguishment time was obtained for each crib size.

  2. The potential predictability of fire danger provided by ECMWF forecast

    NASA Astrophysics Data System (ADS)

    Di Giuseppe, Francesca

    2017-04-01

    The European Forest Fire Information System (EFFIS), is currently being developed in the framework of the Copernicus Emergency Management Services to monitor and forecast fire danger in Europe. The system provides timely information to civil protection authorities in 38 nations across Europe and mostly concentrates on flagging regions which might be at high danger of spontaneous ignition due to persistent drought. The daily predictions of fire danger conditions are based on the US Forest Service National Fire Danger Rating System (NFDRS), the Canadian forest service Fire Weather Index Rating System (FWI) and the Australian McArthur (MARK-5) rating systems. Weather forcings are provided in real time by the European Centre for Medium range Weather Forecasts (ECMWF) forecasting system. The global system's potential predictability is assessed using re-analysis fields as weather forcings. The Global Fire Emissions Database (GFED4) provides 11 years of observed burned areas from satellite measurements and is used as a validation dataset. The fire indices implemented are good predictors to highlight dangerous conditions. High values are correlated with observed fire and low values correspond to non observed events. A more quantitative skill evaluation was performed using the Extremal Dependency Index which is a skill score specifically designed for rare events. It revealed that the three indices were more skilful on a global scale than the random forecast to detect large fires. The performance peaks in the boreal forests, in the Mediterranean, the Amazon rain-forests and southeast Asia. The skill-scores were then aggregated at country level to reveal which nations could potentiallty benefit from the system information in aid of decision making and fire control support. Overall we found that fire danger modelling based on weather forecasts, can provide reasonable predictability over large parts of the global landmass.

  3. Measuring Wildfires From Aircraft And Satellites

    NASA Technical Reports Server (NTRS)

    Brass, J. A.; Arvesen, J. C.; Ambrosia, V. G.; Riggan, P. J.; Meyers, J. S.

    1991-01-01

    Aircraft and satellite systems yield wide-area views, providing total coverage of affected areas. System developed for use aboard aircraft includes digital scanner that records data in 12 channels. Transmits data to ground station for immediate use in fighting fires. Enables researchers to estimate gaseous and particulate emissions from fires. Provides information on temperatures of flame fronts and soils, intensities and rate of spread of fires, characteristics of fuels and smoke plumes, energy-release rates, and concentrations and movements of trace gases. Data relates to heating and cooling of soils, loss of nutrients, and effects on atmospheric, terrestrial, and aquatic systems.

  4. Improvable method for Halon 1301 concentration measurement based on infrared absorption

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Lu, Song; Guan, Yu

    2015-09-01

    Halon 1301 has attached much interest because of its pervasive use as an effective fire suppressant agent in aircraft related fires, and the study of fire suppressant agent concentration measurement is especially of interest. In this work, a Halon 1301 concentration measurement method based on the Beer-Lambert law is developed. IR light is transmitted through mixed gas, and the light intensity with and without the agent present is measured. The intensity ratio is a function of the volume percentage of Halon 1301, and the voltage output of the detector is proportional to light intensity. As such, the relationship between the volume percentage and voltage ratio can be established. The concentration measurement system shows a relative error of the system less than ±2.50%, and a full scale error within 1.20%. This work also discusses the effect of temperature and relative humidity (RH) on the calibration. The experimental results of voltage ratio versus Halon 1301 volume percentage relationship show that the voltage ratio drops significantly as temperature rises from 25 to 100 °C, and it decreases as RH rises from 0% to 100%.

  5. Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.

    2007-04-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.

  6. Impact of air quality in Mexico City due to particles smaller than ten microns (PM10) by wildland fire in "Cumbres del Ajusco Park" for the year 2013

    NASA Astrophysics Data System (ADS)

    Mendoza, A.; Garcia-Reynoso, J. A.; Ruiz-Suárez, L. G.; Torres, R.; Castro, T.; Peralta, O.; Padilla Barrera, Z. V.; Mar, B.; Carbajal, J. N.

    2014-12-01

    A forest fire is a natural process of combustion in a specific geographical area, its occurrence depends on meteorological variables, topography and vegetation type, the wildland fires are potential sources of large amounts of pollutants. The main air pollutants are in a wildland fires particles (PM10 and PM2.5) Carbon Monoxide (CO), nitrogen oxides (NOx), volatile organic compounds (VOC's) and a negligible amount of sulfur dioxide (SO2) (Chow 1995), Was performed a study of the environmental impact on air quality in Mexico city for a wildland fire. The fire was presented in Cumbres del Ajusco Park on April 14 for the year 2013, with a duration of 26 hours and consuming an extension 150 ha of pasture, WRF-Chem and WRF-fire model were used to conduct the study, two modeling scenarios were made, one including emissions from wildfire and other without emission-fire, comparison is made between the two modeling scenarios in order to calculate on air quality in Mexico cityPM10 concentrations have a larger impact on the air quality of Mexico city, when fire emission were included, a plume of PM10 coming from fire increase ambient concentration up to 350ug/m3 and it was obtained by modeling similar to the concentration measured by a monitoring station (320ug/m3).The current limit is 120ug/m3 24 hours average. (Mexican standard NOM-025-SSA1-1993)This system for setting emissions from fire is working properly whoever further development is required.

  7. The FireWork air quality forecast system with near-real-time biomass burning emissions: Recent developments and evaluation of performance for the 2015 North American wildfire season

    PubMed Central

    Pavlovic, Radenko; Chen, Jack; Anderson, Kerry; Moran, Michael D.; Beaulieu, Paul-André; Davignon, Didier; Cousineau, Sophie

    2016-01-01

    ABSTRACT Environment and Climate Change Canada’s FireWork air quality (AQ) forecast system for North America with near-real-time biomass burning emissions has been running experimentally during the Canadian wildfire season since 2013. The system runs twice per day with model initializations at 00 UTC and 12 UTC, and produces numerical AQ forecast guidance with 48-hr lead time. In this work we describe the FireWork system, which incorporates near-real-time biomass burning emissions based on the Canadian Wildland Fire Information System (CWFIS) as an input to the operational Regional Air Quality Deterministic Prediction System (RAQDPS). To demonstrate the capability of the system we analyzed two forecast periods in 2015 (June 2–July 15, and August 15–31) when fire activity was high, and observed fire-smoke-impacted areas in western Canada and the western United States. Modeled PM2.5 surface concentrations were compared with surface measurements and benchmarked with results from the operational RAQDPS, which did not consider near-real-time biomass burning emissions. Model performance statistics showed that FireWork outperformed RAQDPS with improvements in forecast hourly PM2.5 across the region; the results were especially significant for stations near the path of fire plume trajectories. Although the hourly PM2.5 concentrations predicted by FireWork still displayed bias for areas with active fires for these two periods (mean bias [MB] of –7.3 µg m−3 and 3.1 µg m−3), it showed better forecast skill than the RAQDPS (MB of –11.7 µg m−3 and –5.8 µg m−3) and demonstrated a greater ability to capture temporal variability of episodic PM2.5 events (correlation coefficient values of 0.50 and 0.69 for FireWork compared to 0.03 and 0.11 for RAQDPS). A categorical forecast comparison based on an hourly PM2.5 threshold of 30 µg m−3 also showed improved scores for probability of detection (POD), critical success index (CSI), and false alarm rate (FAR). Implications: Smoke from wildfires can have a large impact on regional air quality (AQ) and can expose populations to elevated pollution levels. Environment and Climate Change Canada has been producing operational air quality forecasts for all of Canada since 2009 and is now working to include near-real-time wildfire emissions (NRTWE) in its operational AQ forecasting system. An experimental forecast system named FireWork, which includes NRTWE, has been undergoing testing and evaluation since 2013. A performance analysis of FireWork forecasts for the 2015 wildfire season shows that FireWork provides significant improvements to surface PM2.5 forecasts and valuable guidance to regional forecasters and first responders. PMID:26934496

  8. Hazard mitigation in coal mines

    NASA Astrophysics Data System (ADS)

    Rashmi, R. V.; Devalal, Shilpa; Jacob, Anjali; Vidhyapathi, C. M.

    2017-11-01

    Today’s world witnesses increased number of mine accidents caused due to explosion and fire. When the methane gas concentration goes high, it causes fire leading to explosion. In this paper, an IoT based system is proposed to ensure safety to the mine workers in underground collieries. The proposed system consists of DHT-11 sensor to monitor the temperature and humidity of coal mines. When the gas sensor detects high methane gas level, blower is activated so that the atmospheric air can be pumped in from outside to dilute the gas concentration. The smoke sensor is also used to detect the fire. In case of any abnormality in any of these parameters the buzzer sounds. All these parameters are uploaded to the cloud directly so that the people at the control station can be well informed of the underground mines.

  9. Temporal Trends of NO2, CO and their Relation to the Fire Occurrences over the Indo-Gangetic Plain

    NASA Astrophysics Data System (ADS)

    Pandey, A. K.; Kumar, K.

    2016-12-01

    Air pollution is an environmental issue that has a gigantic impact on human health, and it is a major problem in the densely populated regions throughout the world. Situated in the foothills of the great Himalayas Indo-Gangetic Plain (IGP) is among one of the most densely populated regions of the earth. NO2 and CO are among major air pollutants which affect the air quality of IGP predominantly. In the present study, we studied the temporal trends of NO2, CO and fire count over the IGP region. Further, we investigated the role of the fire occurrences in the ambient NO2 and CO levels. We used MODIS instrument (Aqua satellite), OMI sensor and AIRS instrument data for fire count, Nitrogen Dioxide (NO2) tropospheric column and Carbon monoxide (CO) column study respectively. The IGP is divided into three part geographically i.e. Eastern (E-IGP), Central (C-IGP) and Western (W-IGP). A higher columnar CO concentration is observed in the E-IGP whereas NO2 concentration is highest in the W-IGP. A higher NO2 concentration is obtained in winter followed by summer and a minimum in monsoon months throughout the IGP. Columnar CO concentration is higher in the E-IGP and its concentration is maximum in pre-monsoon months and minimum in the monsoon months. Fire pixel count is highest in the W-IGP with peak twice every year i.e. in the April - May and October - November corresponding to the harvest period in the Rabi-Kharif cropping system. We also obtained a significant positive correlation between fire occurrences and columnar NO2 & CO levels over the IGP which shows the biomass burning practices associated with the agriculture influences the NO2 and CO concentration in the atmosphere.

  10. Contribution of forest fires to concentrations of particulate matter in Singapore

    NASA Astrophysics Data System (ADS)

    Spracklen, D. V.; Reddington, C.; Yoshioka, M.; Arnold, S.; Balasubramanian, R.

    2013-12-01

    Singapore is regularly exposed to substantial levels of transboundary air pollution arising from uncontrolled forest and peat fires from specific regions within Southeast Asia. This air pollution has detrimental impacts on the lives of Singapore residents and on sensitive ecosystems. In June 2013, forest fires resulted in concentrations of particulate matter greatly exceeding levels recommended for human health, causing substantial public concern. We apply two different methods to quantify the impact of forest fires on the concentrations of particulate matter with diameter less than 2.5 micrometres (PM2.5) in Singapore. Firstly, we use a global aerosol model (GLOMAP) in combination with fire emissions from GFED3 to simulate PM2.5 concentrations over the period 1998-2009. We evaluate simulated PM2.5 concentrations against long-term observations from Singapore. To identify the contributions of fires from different source regions to PM2.5 concentrations we run multiple simulations with and without fire emissions from specific regions across Southeast Asia. Secondly, we apply an atmospheric back trajectory model in combination with the GFED3 fire emissions to calculate exposure of air masses arriving in Singapore to fire emissions. Both methods use meteorology from the European Centre for Medium Range Weather Forecasts and are consistent with the large-scale atmospheric flow from the assimilated observations. We find that both methods give consistent results, with forest fires increasing PM2.5 concentrations in Singapore predominately during April to October. Forest and peat fires in Sumatra and Kalimantan cause the greatest degradation of air quality in Singapore. The contribution of fires to PM2.5 concentrations in Singapore exhibits strong interannual variability. During years with a strong contribution from fires, our simulations show that the prevention of fires in southern Sumatra would reduce regional PM2.5 concentrations around Singapore by more than a factor of two, potentially allowing Singapore to meet World Health Organisation guidelines for annual mean concentrations of PM2.5. Acting to reduce forest and peat fires in southern Sumatra, in particular provinces of Lampung, South Sumatra and Jambi, and southern Kalimantan would likely have the greatest environmental benefits to Singapore and surrounding regions.

  11. Demonstration of Spacecraft Fire Safety Technology

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2012-01-01

    During the Constellation Program, the development of spacecraft fire safety technologies were focused on the immediate questions related to the atmosphere of the habitable volume and implementation of fire detection, suppression, and postfire clean-up systems into the vehicle architectures. One of the difficulties encountered during the trade studies for these systems was the frequent lack of data regarding the performance of a technology, such as a water mist fire suppression system or an optically-based combustion product monitor. Even though a spacecraft fire safety technology development project was being funded, there was insufficient time and funding to address all the issues as they were identified. At the conclusion of the Constellation Program, these knowledge gaps formed the basis for a project proposed to the Advanced Exploration Systems (AES) Program. This project, subsequently funded by the AES Program and in operation since October 2011, has as its cornerstone the development of an experiment to be conducted on an ISS resupply vehicle, such as the European Space Agency (ESA) Automated Transfer Vehicle (ATV) or Orbital Science s Cygnus vehicle after it leaves the ISS and before it enters the atmosphere. The technology development efforts being conducted in this project include continued quantification of low- and partial-gravity maximum oxygen concentrations of spacecraft-relevant materials, development and verification of sensors for fire detection and post-fire monitoring, development of standards for sizing and selecting spacecraft fire suppression systems, and demonstration of post-fire cleanup strategies. The major technology development efforts are identified in this paper but its primary purpose is to describe the spacecraft fire safety demonstration being planned for the reentry vehicle.

  12. Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules

    PubMed Central

    Yang, Hong-Yun; Zhou, Xiao-Dong; Yang, Li-Zhong; Zhang, Tao-Lin

    2015-01-01

    Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time (tig), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO2) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m2. This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires. PMID:28793434

  13. Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules.

    PubMed

    Yang, Hong-Yun; Zhou, Xiao-Dong; Yang, Li-Zhong; Zhang, Tao-Lin

    2015-07-09

    Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time ( t ig ), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO₂) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m². This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires.

  14. Assessing the Impact of Fires on Air Quality in the Southeastern U.S. with a Unified Prescribed Burning Database

    NASA Astrophysics Data System (ADS)

    Garcia Menendez, F.; Afrin, S.

    2017-12-01

    Prescribed fires are used extensively across the Southeastern United States and are a major source of air pollutant emissions in the region. These land management projects can adversely impact local and regional air quality. However, the emissions and air pollution impacts of prescribed fires remain largely uncertain. Satellite data, commonly used to estimate fire emissions, is often unable to detect the low-intensity, short-lived prescribed fires characteristic of the region. Additionally, existing ground-based prescribed burn records are incomplete, inconsistent and scattered. Here we present a new unified database of prescribed fire occurrence and characteristics developed from systemized digital burn permit records collected from public and private land management organizations in the Southeast. This bottom-up fire database is used to analyze the correlation between high PM2.5 concentrations measured by monitoring networks in southern states and prescribed fire occurrence at varying spatial and temporal scales. We show significant associations between ground-based records of prescribed fire activity and the observational air quality record at numerous sites by applying regression analysis and controlling confounding effects of meteorology. Furthermore, we demonstrate that the response of measured PM2.5 concentrations to prescribed fire estimates based on burning permits is significantly stronger than their response to satellite fire observations from MODIS (moderate-resolution imaging spectroradiometer) and geostationary satellites or prescribed fire emissions data in the National Emissions Inventory. These results show the importance of bottom-up smoke emissions estimates and reflect the need for improved ground-based fire data to advance air quality impacts assessments focused on prescribed burning.

  15. Post-wildfire erosion in mountainous terrain leads to rapid and major redistribution of soil organic carbon

    NASA Astrophysics Data System (ADS)

    Abney, Rebecca B.; Sanderman, Jonathan; Johnson, Dale; Fogel, Marilyn L.; Berhe, Asmeret Asefaw

    2017-11-01

    Catchments impacted by wildfire typically experience elevated rates of post-fire erosion and formation and deposition of pyrogenic carbon (PyC). To better understand the role of erosion in post-fire soil carbon dynamics, we determined distribution of soil organic carbon in different chemical fractions before and after the Gondola fire in South Lake Tahoe, CA. We analyzed soil samples from eroding and depositional landform positions in control and burned plots pre- and post-wildfire (in 2002, 2003, and 10-years post-fire in 2013). We determined elemental concentrations, stable isotope compositions, and biochemical composition of organic matter (OM) using mid-infrared (MIR) spectroscopy for all of the samples. A subset of samples was analyzed by 13C cross polarization magic angle spinning nuclear magnetic resonance spectroscopy (CPMAS 13C-NMR). We combined the MIR and CPMAS 13C-NMR data in the Soil Carbon Research Program partial least squares regression model to predict distribution of soil carbon into three different fractions: 1) particulate, humic, and resistant organic matter fractions representing relatively fresh larger pieces of OM, 2) fine, decomposed OM, and 3) pyrogenic C, respectively. Samples from the post-fire eroding landform position showed no major difference in soil organic carbon (SOC) fractions one year post-fire. The depositional samples, however, had increased concentrations of all SOC fractions, particularly the fraction that resembles PyC, one year post-fire (2002), which had a mean of 160 g/kg compared with burned hillslope soils, which had 84 g/kg. The increase in all SOC fractions in the post-fire depositional landform position one year post-fire indicates significant lateral mobilization of the eroded PyC. In addition, our NMR analyses revealed a post-fire increase in both the aryl and O-aryl carbon compounds in the soils from the depositional landform position, indicating increases in soil PyC concentrations post-fire. After 10 years, the C concentration from all three fractions declined in the depositional landform position to below pre-fire levels likely due to further erosion or elevated rates of decomposition. Thus, we found, at this site, that both fire and erosion exert significant influence on the distribution of PyC throughout a landscape and its long-term fate in the soil system.

  16. Water vapour emission in vegetable fuel: absorption cell measurements and detection limits of our CO II Dial system

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; De Leo, L.; Gaudio, P.; Gelfusa, M.; Lo Feudo, T.; Martellucci, S.; Richetta, M.

    2006-09-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason a considerable effort has been directed toward the forest protection and fire fighting. In the early forest fire detection, Lidar technique present considerable advantages compared to the passive detection methods based on infrared cameras currently in common use, due its higher sensitivity and ability to accurately locate the fire. The combustion phase of the vegetable matter causes a great amount of water vapour emission, thus the water molecule behaviour will be studied to obtain a fire detection system ready and efficient also before the flame propagation. A first evaluation of increment of the water vapour concentration compared to standard one will be estimated by a numerical simulation. These results will be compared with the experimental measurements carried out into a cell with a CO II Dial system, burning different kinds of vegetable fuel. Our results and their comparison will be reported in this paper.

  17. "Smoke": Characterization Of Smoke Particulate For Spacecraft Fire Detection

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Mulholland, George W.; Yang, Jiann; Cleary, Thomas G.; Yuan, Zeng-Guang

    2003-01-01

    The "Smoke" experiment is a flight definition investigation that seeks to increase our understanding of spacecraft fire detection through measurements of particulate size distributions of preignition smokes from typical spacecraft materials. Owing to the catastrophic risk posed by even a very small fire in a spacecraft, the design goal for spacecraft fire detection is to detect the fire as quickly as possible, preferably in the preignition phase before a real flaming fire has developed. Consequently the target smoke for detection is typically not soot (typical of established hydrocarbon fires) but instead, pyrolysis products, and recondensed polymer particles. At the same time, false alarms are extremely costly as the crew and the ground team must respond quickly to every alarm. The U.S. Space Shuttle (STS: Space Transportation System) and the International Space Station (ISS) both use smoke detection as the primary means of fire detection. These two systems were designed in the absence of any data concerning low-gravity smoke particle (and background dust) size distributions. The STS system uses an ionization detector coupled with a sampling pump and the ISS system is a forward light scattering detector operating in the near IR. These two systems have significantly different sensitivities with the ionization detector being most sensitive (on a mass concentration basis) to smaller particulate and the light scattering detector being most sensitive to particulate that is larger than 1 micron. Since any smoke detection system has inherent size sensitivity characteristics, proper design of future smoke detection systems will require an understanding of the background and alarm particle size distributions that can be expected in a space environment.

  18. Characterization of exposure to byproducts from firing lead-free frangible ammunition in an enclosed, ventilated firing range.

    PubMed

    Grabinski, Christin M; Methner, Mark M; Jackson, Jerimiah M; Moore, Alexander L; Flory, Laura E; Tilly, Trevor; Hussain, Saber M; Ott, Darrin K

    2017-06-01

    U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = <1 µg/m 3 to 16 µg/m 3 ), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.

  19. Spacecraft Fire Safety Research at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Meyer, Marit

    2016-01-01

    Appropriate design of fire detection systems requires knowledge of both the expected fire signature and the background aerosol levels. Terrestrial fire detection systems have been developed based on extensive study of terrestrial fires. Unfortunately there is no corresponding data set for spacecraft fires and consequently the fire detectors in current spacecraft were developed based upon terrestrial designs. In low gravity, buoyant flow is negligible which causes particles to concentrate at the smoke source, increasing their residence time, and increasing the transport time to smoke detectors. Microgravity fires have significantly different structure than those in 1-g which can change the formation history of the smoke particles. Finally the materials used in spacecraft are different from typical terrestrial environments where smoke properties have been evaluated. It is critically important to detect a fire in its early phase before a flame is established, given the fixed volume of air on any spacecraft. Consequently, the primary target for spacecraft fire detection is pyrolysis products rather than soot. Experimental investigations have been performed at three different NASA facilities which characterize smoke aerosols from overheating common spacecraft materials. The earliest effort consists of aerosol measurements in low gravity, called the Smoke Aerosol Measurement Experiment (SAME), and subsequent ground-based testing of SAME smoke in 55-gallon drums with an aerosol reference instrument. Another set of experiments were performed at NASAs Johnson Space Center White Sands Test Facility (WSTF), with additional fuels and an alternate smoke production method. Measurements of these smoke products include mass and number concentration, and a thermal precipitator was designed for this investigation to capture particles for microscopic analysis. The final experiments presented are from NASAs Gases and Aerosols from Smoldering Polymers (GASP) Laboratory, with selected results focusing on realistic fuel preparations and heating profiles with regards to early detection of smoke. SAFFIRE is the upcoming large-scale fire experiment which will be executed in a Cygnus vehicle after it undocks from the ISS.

  20. Environmental assessment of a wood-waste-fired industrial watertube boiler. Volume 1. Technical results. Final report, March 1981-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castaldini, C.; Waterland, L.R.

    1987-03-01

    The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue-gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less

  1. Environmental assessment of a wood-waste-fired industrial watertube boiler. Volume 2. Data supplement. Final report, March 1981-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castaldini, C.; Waterland, L.R.

    1987-03-01

    The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic and organic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less

  2. An operational system for the assimilation of satellite information on wild-land fires for the needs of air quality modelling and forecasting

    NASA Astrophysics Data System (ADS)

    Sofiev, M.; Vankevich, R.; Lanne, M.; Prank, M.; Petukhov, V.; Ermakova, T.; Kukkonen, J.

    2009-03-01

    This paper investigates a potential of two remotely sensed wild-land fire characteristics: 4-μm Brightness Temperature Anomaly (TA) and Fire Radiative Power (FRP) for the needs of operational chemical transport modelling and the short-term forecasting of the atmospheric composition and air quality. Two treatments of the TA and FRP data are presented and a methodology for evaluating the emission fluxes is described. The method does not contain a complicated analysis of vegetation state, fuel load, burning efficiency and related factors, which are comparatively uncertain but inevitably involved in approaches based on burnt-area scars or similar products. The core of the current methodology is based on the empirical emission factors that have been derived from the analysis of several fire episodes in Europe (28 April-5 May 2006, 15-25 August 2006, August 2008 etc.). These episodes were characterised by: (i) well-identified FRP and TA values, and (ii) available independent observations of aerosol concentrations and optical thickness for the regions where fire smoke was dominant in comparison with contributions of other pollution sources. The emission factors were determined separately for the forested and grassland areas; in case of mixed-type land use an intermediate scaling was assumed. Despite significant difference between the TA and FRP products, an accurate non-linear fitting between the approaches was found. The agreement was comparatively weak only for small fires where the accuracy of both products is low. The re-analysis and forecasting applications of the Fire Assimilation System (FAS) showed that both TA and FRP products are suitable for evaluation of the emission fluxes from the wild-land fires. The concentrations of aerosols predicted by the regional dispersion modelling system SILAM appear within a factor of 2-3 from observations. The main areas of improvement include further refining the emission factors over the globe, explicit determination and appropriate treatment of the type of fires, evaluation of the injection height of the plumes and predicting the fire temporal evolution.

  3. Using JPSS VIIRS Fire Radiative Power Data to Forecast Biomass Burning Emissions and Smoke Transport by the High Resolution Rapid Refresh Model

    NASA Astrophysics Data System (ADS)

    Ahmadov, R.; Grell, G. A.; James, E.; Alexander, C.; Stewart, J.; Benjamin, S.; McKeen, S. A.; Csiszar, I. A.; Tsidulko, M.; Pierce, R. B.; Pereira, G.; Freitas, S. R.; Goldberg, M.

    2017-12-01

    We present a new real-time smoke modeling system, the High Resolution Rapid Refresh coupled with smoke (HRRR-Smoke), to simulate biomass burning (BB) emissions, plume rise and smoke transport in real time. The HRRR is the NOAA Earth System Research Laboratory's 3km grid spacing version of the Weather Research and Forecasting (WRF) model used for weather forecasting. Here we make use of WRF-Chem (the WRF model coupled with chemistry) and simulate fine particulate matter (smoke) emissions emitted by BB. The HRRR-Smoke modeling system ingests fire radiative power (FRP) data from the Visible Infrared Imaging Radiometer Suite (VIIRS) sensor on the Suomi National Polar-orbiting Partnership (S-NPP) satellite to calculate BB emissions. The FRP product is based on processing 750m resolution "M" bands. The algorithms for fire detection and FRP retrieval are consistent with those used to generate the MODIS fire detection data. For the purpose of ingesting VIIRS fire data into the HRRR-Smoke model, text files are generated to provide the location and detection confidence of fire pixels, as well as FRP. The VIIRS FRP data from the text files are processed and remapped over the HRRR-Smoke model domains. We process the FRP data to calculate BB emissions (smoldering part) and fire size for the model input. In addition, HRRR-Smoke uses the FRP data to simulate the injection height for the flaming emissions using concurrently simulated meteorological fields by the model. Currently, there are two 3km resolution domains covering the contiguous US and Alaska which are used to simulate smoke in real time. In our presentation, we focus on the CONUS domain. HRRR-Smoke is initialized 4 times per day to forecast smoke concentrations for the next 36 hours. The VIIRS FRP data, as well as near-surface and vertically integrated smoke mass concentrations are visualized for every forecast hour. These plots are provided to the public via the HRRR-Smoke web-page: https://rapidrefresh.noaa.gov/HRRRsmoke/. Model evaluations for a case study are presented, where simulated smoke concentrations are compared with hourly PM2.5 measurements from EPA's Air Quality System network. These comparisons demonstrate the model's ability in simulating high aerosol loadings during major wildfire events in the western US.

  4. Co-firing coal and biomass blends and their influence on the post-combustion CO2 capture installation

    NASA Astrophysics Data System (ADS)

    Więckol-Ryk, Angelika; Smoliński, Adam

    2017-10-01

    Co-firing of biomass with coal for energy production is a well-known technology and plays an important role in the electricity sector. The post-combustion capture integrated with biomass-fired power plants (Bio-CCS) seems to be a new alternative for reducing greenhouse gas emissions. This study refers to the best known and advanced technology for post-combustion CO2 capture (PCC) based on a chemical absorption in monoethanolamine (MEA). The co-firing of hard coal with four types of biomass was investigated using a laboratory fixed bed reactor system. The comparison of gaseous products emitted from the combustion of coal and different biomass blends were determined using gas chromatography. Research proved that co-firing of biomass in fossil fuel power plants is beneficial for PCC process. It may also reduce the corrosion of CO2 capture installation. The oxygen concentration in the flue gases from hard coal combustion was comparable with the respective value for a fuel blend of biomass content of 20% w/w. It was also noted that an increase in biomass content in a sample from 20 to 40 % w/w increased the concentration of oxygen in the flue gas streams. However, this concentration should not have a significant impact on the rate of amine oxidative degradation.

  5. Modeling acute respiratory illness during the 2007 San Diego wildland fires using a coupled emissions-transport system and generalized additive modeling.

    PubMed

    Thelen, Brian; French, Nancy H F; Koziol, Benjamin W; Billmire, Michael; Owen, Robert Chris; Johnson, Jeffrey; Ginsberg, Michele; Loboda, Tatiana; Wu, Shiliang

    2013-11-05

    A study of the impacts on respiratory health of the 2007 wildland fires in and around San Diego County, California is presented. This study helps to address the impact of fire emissions on human health by modeling the exposure potential of proximate populations to atmospheric particulate matter (PM) from vegetation fires. Currently, there is no standard methodology to model and forecast the potential respiratory health effects of PM plumes from wildland fires, and in part this is due to a lack of methodology for rigorously relating the two. The contribution in this research specifically targets that absence by modeling explicitly the emission, transmission, and distribution of PM following a wildland fire in both space and time. Coupled empirical and deterministic models describing particulate matter (PM) emissions and atmospheric dispersion were linked to spatially explicit syndromic surveillance health data records collected through the San Diego Aberration Detection and Incident Characterization (SDADIC) system using a Generalized Additive Modeling (GAM) statistical approach. Two levels of geographic aggregation were modeled, a county-wide regional level and division of the county into six sub regions. Selected health syndromes within SDADIC from 16 emergency departments within San Diego County relevant for respiratory health were identified for inclusion in the model. The model captured the variability in emergency department visits due to several factors by including nine ancillary variables in addition to wildfire PM concentration. The model coefficients and nonlinear function plots indicate that at peak fire PM concentrations the odds of a person seeking emergency care is increased by approximately 50% compared to non-fire conditions (40% for the regional case, 70% for a geographically specific case). The sub-regional analyses show that demographic variables also influence respiratory health outcomes from smoke. The model developed in this study allows a quantitative assessment and prediction of respiratory health outcomes as it relates to the location and timing of wildland fire emissions relevant for application to future wildfire scenarios. An important aspect of the resulting model is its generality thus allowing its ready use for geospatial assessments of respiratory health impacts under possible future wildfire conditions in the San Diego region. The coupled statistical and process-based modeling demonstrates an end-to-end methodology for generating reasonable estimates of wildland fire PM concentrations and health effects at resolutions compatible with syndromic surveillance data.

  6. An operational system for the assimilation of the satellite information on wild-land fires for the needs of air quality modelling and forecasting

    NASA Astrophysics Data System (ADS)

    Sofiev, M.; Vankevich, R.; Lotjonen, M.; Prank, M.; Petukhov, V.; Ermakova, T.; Koskinen, J.; Kukkonen, J.

    2009-09-01

    This paper investigates a potential of two remotely sensed wild-land fire characteristics: 4-μm Brightness Temperature Anomaly (TA) and Fire Radiative Power (FRP) for the needs of operational chemical transport modelling and short-term forecasting of atmospheric composition and air quality. The treatments of the TA and FRP data are presented and a methodology for evaluating the emission fluxes of primary aerosols (PM2.5 and total PM) is described. The method does not include the complicated analysis of vegetation state, fuel load, burning efficiency and related factors, which are uncertain but inevitably involved in approaches based on burnt-area scars or similar products. The core of the current methodology is based on the empirical emission factors that are used to convert the observed temperature anomalies and fire radiative powers into emission fluxes. These factors have been derived from the analysis of several fire episodes in Europe (28.4-5.5.2006, 15.8-25.8.2006 and in August 2008). These episodes were characterised by: (i) well-identified FRP and TA values, and (ii) available ground-based observations of aerosol concentrations, and optical thickness for the regions where the contribution of the fire smoke to the concentrations of PM2.5 was dominant, in comparison with those of other pollution sources. The emission factors were determined separately for the forested and grassland areas; in case of mixed-type land use, an intermediate scaling was assumed. Despite significant differences between the TA and FRP methodologies, an accurate non-linear fitting was found between the predictions of these approaches. The agreement was comparatively weak only for small fires, for which the accuracy of both products is expected to be low. The applications of the Fire Assimilation System (FAS) in combination with the dispersion model SILAM showed that both the TA and FRP products are suitable for the evaluation of the emission fluxes from wild-land fires. The fire-originated concentrations of aerosols (PM2.5, PM10, sulphates and nitrates) and AOD, as predicted by the SILAM model were mainly within a factor of 2-3 compared with the observations. The main challenges of the FAS improvement include refining of the emission factors globally, determination of the types of fires (smouldering vs flaming), evaluation of the injection heights of the plumes, and predicting the temporal evolution of fires.

  7. Carbon Dioxide Dispersion in the Combustion Integrated Rack Simulated Numerically

    NASA Technical Reports Server (NTRS)

    Wu, Ming-Shin; Ruff, Gary A.

    2004-01-01

    When discharged into an International Space Station (ISS) payload rack, a carbon dioxide (CO2) portable fire extinguisher (PFE) must extinguish a fire by decreasing the oxygen in the rack by 50 percent within 60 sec. The length of time needed for this oxygen reduction throughout the rack and the length of time that the CO2 concentration remains high enough to prevent the fire from reigniting is important when determining the effectiveness of the response and postfire procedures. Furthermore, in the absence of gravity, the local flow velocity can make the difference between a fire that spreads rapidly and one that self-extinguishes after ignition. A numerical simulation of the discharge of CO2 from PFE into the Combustion Integrated Rack (CIR) in microgravity was performed to obtain the local velocity and CO2 concentration. The complicated flow field around the PFE nozzle exits was modeled by sources of equivalent mass and momentum flux at a location downstream of the nozzle. The time for the concentration of CO2 to reach a level that would extinguish a fire anywhere in the rack was determined using the Fire Dynamics Simulator (FDS), a computational fluid dynamics code developed by the National Institute of Standards and Technology specifically to evaluate the development of a fire and smoke transport. The simulation shows that CO2, as well as any smoke and combustion gases produced by a fire, would be discharged into the ISS cabin through the resource utility panel at the bottom of the rack. These simulations will be validated by comparing the results with velocity and CO2 concentration measurements obtained during the fire suppression system verification tests conducted on the CIR in March 2003. Once these numerical simulations are validated, portions of the ISS labs and living areas will be modeled to determine the local flow conditions before, during, and after a fire event. These simulations can yield specific information about how long it takes for smoke and combustion gases produced by a fire to reach a detector location, how large the fire would be when the detector alarms, and the behavior of the fire until it has been extinguished. This new capability could then be used to optimize the location of fire detectors and fire-suppression ports as well as to evaluate the effectiveness of fire suppressants and response strategies. Numerical data collected from these simulations could also be used to develop a virtual reality fire event for crew training and fire safety awareness. This work is funded by NASA's Bioastronautics Initiative, which has the objective of ensuring and enhancing the health, safety, and performance of humans in space. As part of this initiative, the Microgravity Combustion Science Branch at the NASA Glenn Research Center is conducting spacecraft fire safety research to significantly improve fire safety on inhabited spacecraft.

  8. Measurement of the spatial dependence of temperature and gas and soot concentrations within large open hydrocarbon fuel fires

    NASA Technical Reports Server (NTRS)

    Johnson, H. T.; Linley, L. J.; Mansfield, J. A.

    1982-01-01

    A series of large-scale JP-4 fuel pool fire tests was conducted to refine existing mathematical models of large fires. Seven tests were conducted to make chemical concentration and temperature measurements in 7.5 and 15 meter-diameter pool fires. Measurements were made at heights of 0.7, 1.4, 2.9, 5.7, 11.4, and 21.3 meters above the fires. Temperatures were measured at up to 50 locations each second during the fires. Chemistry samples were taken at up to 23 locations within the fires and analyzed for combustion chemistry and soot concentration. Temperature and combustion chemistry profiles obtained during two 7.5 meter-diameter and two 15 meter-diameter fires are included.

  9. Overview and Evaluation of a Smoke Modeling System and other Tools used during Wildfire Incident Deployments

    NASA Astrophysics Data System (ADS)

    ONeill, S. M.; Larkin, N. K.; Martinez, M.; Rorig, M.; Solomon, R. C.; Dubowy, J.; Lahm, P. W.

    2017-12-01

    Specialists operationally deployed to wildfires to forecast expected smoke conditions for the public use many tools and information. These Air Resource Advisors (ARAs) are deployed as part of the Wildland Fire Air Quality Response Program (WFAQRP) and rely on smoke models, monitoring data, meteorological information, and satellite information to produce daily Smoke Outlooks for a region impacted by smoke from wildfires. These Smoke Outlooks are distributed to air quality and health agencies, published online via smoke blogs and other social media, and distributed by the Incident Public Information Officer (PIO), and ultimately to the public. Fundamental to these operations are smoke modeling systems such as the BlueSky Smoke Modeling Framework, which combines fire activity information, mapped fuel loadings, consumption and emissions models, and air quality/dispersion models such as HYSPLIT to produce predictions of PM2.5 concentrations downwind of wildland fires. Performance of this system at a variety of meteorological resolutions, fire initialization information, and vertical allocation of emissions is evaluated for the Summer of 2015 when over 400,000 hectares burned in the northwestern US state of Washington and 1-hr average fine particulate matter (PM2.5) concentrations exceeded 700 μg/m3. The performance of the system at the 12-km, 4-km, and 1.33-km resolutions is evaluated using 1-hr average PM2.5 measurements from permanent monitors and temporary monitors deployed specifically for wildfires by ARAs on wildfire incident command teams. At the higher meteorological resolution (1.33-km) the terrain features are more detailed, showing better valley structures and in general, PM2.5 concentrations were greater in the valleys with the 1.33-km meteorological domain than with the 4-km domain.

  10. Trace elements in stormflow, ash, and burned soil following the 2009 station fire in southern California

    USGS Publications Warehouse

    Burton, Carmen; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.

    2016-01-01

    Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life.

  11. Trace Elements in Stormflow, Ash, and Burned Soil following the 2009 Station Fire in Southern California

    PubMed Central

    Burton, Carmen A.; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.

    2016-01-01

    Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life. PMID:27144270

  12. A human-driven decline in global burned area.

    PubMed

    Andela, N; Morton, D C; Giglio, L; Chen, Y; van der Werf, G R; Kasibhatla, P S; DeFries, R S; Collatz, G J; Hantson, S; Kloster, S; Bachelet, D; Forrest, M; Lasslop, G; Li, F; Mangeon, S; Melton, J R; Yue, C; Randerson, J T

    2017-06-30

    Fire is an essential Earth system process that alters ecosystem and atmospheric composition. Here we assessed long-term fire trends using multiple satellite data sets. We found that global burned area declined by 24.3 ± 8.8% over the past 18 years. The estimated decrease in burned area remained robust after adjusting for precipitation variability and was largest in savannas. Agricultural expansion and intensification were primary drivers of declining fire activity. Fewer and smaller fires reduced aerosol concentrations, modified vegetation structure, and increased the magnitude of the terrestrial carbon sink. Fire models were unable to reproduce the pattern and magnitude of observed declines, suggesting that they may overestimate fire emissions in future projections. Using economic and demographic variables, we developed a conceptual model for predicting fire in human-dominated landscapes. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  13. Fire emissions and regional air quality impacts from fires in oil palm, timber, and logging concessions in Indonesia

    NASA Astrophysics Data System (ADS)

    Marlier, Miriam E.; DeFries, Ruth S.; Kim, Patrick S.; Koplitz, Shannon N.; Jacob, Daniel J.; Mickley, Loretta J.; Myers, Samuel S.

    2015-08-01

    Fires associated with agricultural and plantation development in Indonesia impact ecosystem services and release emissions into the atmosphere that degrade regional air quality and contribute to greenhouse gas concentrations. In this study, we estimate the relative contributions of the oil palm, timber (for wood pulp and paper), and logging industries in Sumatra and Kalimantan to land cover change, fire activity, and regional population exposure to smoke concentrations. Concessions for these three industries cover 21% and 49% of the land area in Sumatra and Kalimantan respectively, with the highest overall area in lowlands on mineral soils instead of more carbon-rich peatlands. In 2012, most remaining forest area was located in logging concessions for both islands, and for all combined concessions, there was higher remaining lowland and peatland forest area in Kalimantan (45% and 46%, respectively) versus Sumatra (20% and 27%, respectively). Emissions from all combined concessions comprised 41% of total fire emissions (within and outside of concession boundaries) in Sumatra and 27% in Kalimantan for the 2006 burning season, which had high fire activity relative to decadal emissions. Most fire emissions were observed in concessions located on peatlands and non-forested lowlands, the latter of which could include concessions that are currently under production, cleared in preparation for production, or abandoned lands. For the 2006 burning season, timber concessions from Sumatra (47% of area and 88% of emissions) and oil palm concessions from Kalimantan (33% of area and 67% of emissions) contributed the most to concession-related fire emissions from each island. Although fire emissions from concessions were higher in Kalimantan, emissions from Sumatra contributed 63% of concession-related smoke concentrations for the population-weighted region because fire sources were located closer to population centers. In order to protect regional public health, our results highlight the importance of limiting the use of fire by the timber and oil palm industries, particularly on concessions that contain peatlands and non-forest, by such methods as improving monitoring systems, local-level management, and enforcement of existing fire bans.

  14. Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight

    NASA Technical Reports Server (NTRS)

    Graf, John

    2011-01-01

    NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.

  15. Regional air quality impacts of future fire emissions in Sumatra and Kalimantan

    NASA Astrophysics Data System (ADS)

    Marlier, Miriam E.; DeFries, Ruth S.; Kim, Patrick S.; Gaveau, David L. A.; Koplitz, Shannon N.; Jacob, Daniel J.; Mickley, Loretta J.; Margono, Belinda A.; Myers, Samuel S.

    2015-05-01

    Fire emissions associated with land cover change and land management contribute to the concentrations of atmospheric pollutants, which can affect regional air quality and climate. Mitigating these impacts requires a comprehensive understanding of the relationship between fires and different land cover change trajectories and land management strategies. We develop future fire emissions inventories from 2010-2030 for Sumatra and Kalimantan (Indonesian Borneo) to assess the impact of varying levels of forest and peatland conservation on air quality in Equatorial Asia. To compile these inventories, we combine detailed land cover information from published maps of forest extent, satellite fire radiative power observations, fire emissions from the Global Fire Emissions Database, and spatially explicit future land cover projections using a land cover change model. We apply the sensitivities of mean smoke concentrations to Indonesian fire emissions, calculated by the GEOS-Chem adjoint model, to our scenario-based future fire emissions inventories to quantify the different impacts of fires on surface air quality across Equatorial Asia. We find that public health impacts are highly sensitive to the location of fires, with emissions from Sumatra contributing more to smoke concentrations at population centers across the region than Kalimantan, which had higher emissions by more than a factor of two. Compared to business-as-usual projections, protecting peatlands from fires reduces smoke concentrations in the cities of Singapore and Palembang by 70% and 40%, and by 60% for the Equatorial Asian region, weighted by the population in each grid cell. Our results indicate the importance of focusing conservation priorities on protecting both forested (intact or logged) peatlands and non-forested peatlands from fire, even after considering potential leakage of deforestation pressure to other areas, in order to limit the impact of fire emissions on atmospheric smoke concentrations and subsequent health effects.

  16. Stormwater and fire as sources of black carbon nanoparticles to Lake Tahoe.

    PubMed

    Bisiaux, Marion M; Edwards, Ross; Heyvaert, Alan C; Thomas, James M; Fitzgerald, Brian; Susfalk, Richard B; Schladow, S Geoffrey; Thaw, Melissa

    2011-03-15

    Emitted to the atmosphere through fire and fossil fuel combustion, refractory black carbon nanoparticles (rBC) impact human health, climate, and the carbon cycle. Eventually these particles enter aquatic environments, where they may affect the fate of other pollutants. While ubiquitous, the particles are still poorly characterized in freshwater systems. Here we present the results of a study determining rBC in waters of the Lake Tahoe watershed in the western United States from 2007 to 2009. The study period spanned a large fire within the Tahoe basin, seasonal snowmelt, and a number of storm events, which resulted in pulses of urban runoff into the lake with rBC concentrations up to 4 orders of magnitude higher than midlake concentrations. The results show that rBC pulses from both the fire and urban runoff were rapidly attenuated suggesting unexpected aggregation or degradation of the particles. We find that those processes prevent rBC concentrations from building up in the clear and oligotrophic Lake Tahoe. This rapid removal of rBC soon after entry into the lake has implications for the transport of rBC in the global aquatic environment and the flux of rBC from continents to the global ocean.

  17. Integrating Measurement Based New Knowledge on Wildland Fire Emissions and Chemistry into the AIRPACT Air Quality Forecasting for the Pacific Northwest

    NASA Astrophysics Data System (ADS)

    Nergui, T.; Lee, Y.; Chung, S. H.; Lamb, B. K.; Yokelson, R. J.; Barsanti, K.

    2017-12-01

    A number of chamber and field measurements have shown that atmospheric organic aerosols and their precursors produced from wildfires are significantly underestimated in the emission inventories used for air quality models for various applications such as regulatory strategy development, impact assessments of air pollutants, and air quality forecasting for public health. The AIRPACT real-time air quality forecasting system consistently underestimates surface level fine particulate matter (PM2.5) concentrations in the summer at both urban and rural locations in the Pacific Northwest, primarily result of errors in organic particulate matter. In this work, we implement updated chemical speciation and emission factors based on FLAME-IV (Fourth Fire Lab at Missoula Experiment) and other measurements in the Blue-Sky fire emission model and the SMOKE emission preprocessor; and modified parameters for the secondary organic aerosol (SOA) module in CMAQ chemical transport model of the AIRPACT modeling system. Simulation results from CMAQ version 5.2 which has a better treatment for anthropogenic SOA formation (as a base case) and modified parameterization used for fire emissions and chemistry in the model (fire-soa case) are evaluated against airborne measurements downwind of the Big Windy Complex Fire and the Colockum Tarps Fire, both of which occurred in the Pacific Northwest in summer 2013. Using the observed aerosol chemical composition and mass loadings for organics, nitrate, sulfate, ammonium, and chloride from aircraft measurements during the Studies of Emissions and Atmospheric Composition, Clouds, and Climate Coupling by Regional Surveys (SEAC4RS) and the Biomass Burning Observation Project (BBOP), we assess how new knowledge gained from wildfire measurements improve model predictions for SOA and its contribution to the total mass of PM2.5 concentrations.

  18. Climate and human intervention effects on future fire activity and consequences for air pollution across the 21st century

    NASA Astrophysics Data System (ADS)

    Val Martin, M.; Pierce, J. R.; Heald, C. L.; Li, F.; Lawrence, D. M.; Wiedinmyer, C.; Tilmes, S.; Vitt, F.

    2016-12-01

    Emissions of aerosols and gases from fires have been shown to adversely affect air quality across the world. Fire activity is strongly related to climate and anthropogenic activities. Current fire projections for the 21st century seem very uncertain, ranging from increasing to declining depending on the climate, land cover change and population growth scenarios used. Here we present an analysis of the changes in future wildfire activity and consequences on air quality, with focus on PM2.5 and surface O3 over regions vulnerable to fire. We use the global Community Earth System Model (CESM) with a process-based fire model to simulate emissions from agriculture, peatland, deforestation and landscape fires for present-day and throughout the current century. We consider two future Representative Concentration Pathways climate scenarios combined with population density changes predicted from Shared Socio-economic Pathways to project climate and demographic effects on fire activity and further consequences for future air quality.

  19. The Simulations of Wildland Fire Smoke PM25 in the NWS Air Quality Forecasting Systems

    NASA Astrophysics Data System (ADS)

    Huang, H. C.; Pan, L.; McQueen, J.; Lee, P.; ONeill, S. M.; Ruminski, M.; Shafran, P.; Huang, J.; Stajner, I.; Upadhayay, S.; Larkin, N. K.

    2017-12-01

    The increase of wildland fire intensity and frequency in the United States (U.S.) has led to property loss, human fatality, and poor air quality due to elevated particulate matters and surface ozone concentrations. The NOAA/National Weather Service (NWS) built the National Air Quality Forecast Capability (NAQFC) based on the U.S. Environmental Protection Agency (EPA) Community Multi-scale Air Quality (CMAQ) Modeling System driven by the NCEP North American Mesoscale Forecast System meteorology to provide ozone and fine particulate matter (PM2.5) forecast guidance publicly. State and local forecasters use the NWS air quality forecast guidance to issue air quality alerts in their area. The NAQFC PM2.5 predictions include emissions from anthropogenic and biogenic sources, as well as natural sources such as dust storms and wildland fires. The wildland fire emission inputs to the NAQFC is derived from the NOAA National Environmental Satellite, Data, and Information Service Hazard Mapping System fire and smoke detection product and the emission module of the U.S. Forest Service (USFS) BlueSky Smoke Modeling Framework. Wildland fires are unpredictable and can be ignited by natural causes such as lightning or be human-caused. It is extremely difficult to predict future occurrences and behavior of wildland fires, as is the available bio-fuel to be burned for real-time air quality predictions. Assumptions of future day's wildland fire behavior often have to be made from older observed wildland fire information. The comparisons between the NAQFC modeled PM2.5 and the EPA AirNow surface observation show that large errors in PM2.5 prediction can occur if fire smoke emissions are sometimes placed at the wrong location and/or time. A configuration of NAQFC CMAQ-system to re-run previous 24 hours, during which wildland fires were observed from satellites has been included recently. This study focuses on the effort performed to minimize the error in NAQFC PM2.5 predictions resulting from incorporating fire smoke emissions into the NAQFC from a recently updated newer version of USFS BlueSky system. This study will show how new approaches has improved the PM2.5 predictions at both nearby and downstream areas from fire sources. Furthermore, Environment and Climate Change Canada (ECCC) fire emissions data are being tested.

  20. Mean field model of acetylcholine mediated dynamics in the cerebral cortex.

    PubMed

    Clearwater, J M; Rennie, C J; Robinson, P A

    2007-12-01

    A recent continuum model of the large scale electrical activity of the cerebral cortex is generalized to include cholinergic modulation. In this model, dynamic modulation of synaptic strength acts over the time scales of nicotinic and muscarinic receptor action. The cortical model is analyzed to determine the effect of acetylcholine (ACh) on its steady states, linear stability, spectrum, and temporal responses to changes in subcortical input. ACh increases the firing rate in steady states of the system. Changing ACh concentration does not introduce oscillatory behavior into the system, but increases the overall spectral power. Model responses to pulses in subcortical input are affected by the tonic level of ACh concentration, with higher levels of ACh increasing the magnitude firing rate response of excitatory cortical neurons to pulses of subcortical input. Numerical simulations are used to explore the temporal dynamics of the model in response to changes in ACh concentration. Evidence is seen of a transition from a state in which intracortical inputs are emphasized to a state where thalamic afferents have enhanced influence. Perturbations in ACh concentration cause changes in the firing rate of cortical neurons, with rapid responses due to fast acting facilitatory effects of nicotinic receptors on subcortical afferents, and slower responses due to muscarinic suppression of intracortical connections. Together, these numerical simulations demonstrate that the actions of ACh could be a significant factor modulating early components of evoked response potentials.

  1. Contribution of Emissions from Coal-fired Power Plants in Chungcheongnam-do to PM2.5 Concentrations in South Korea during the 2016 KORUS-AQ

    NASA Astrophysics Data System (ADS)

    You, S.; Kim, S.; Kim, B. U.; Kim, H. C.; Lim, Y. J.

    2017-12-01

    In recent years, high concentration events of particulate matter (PM) are frequently found in South Korea, and air pollutants emitted from coal-fired power plants are known to aggravate PM concentrations. Geographically, large point sources such as major thermal power generation facilities are located in Chungcheongnam-do (CN), which is adjacent to the Seoul Metropolitan Area. Air pollutants emitted from these power generation facilities have an influence on PM2.5 concentrations in CN and downwind areas. In this study, 3-D photochemical simulation using CMAQ was performed to spatiotemporally analyze the contribution of the emission amount from coal-fired power plants in CN to PM2.5 concentrations in the area and downwind areas, and zero-out contribution was calculated through additional BFM simulations. Prior to this, the model results and the input data were evaluated through the comparison using the aerial observation (DC-8, King-Air) carried out during the KORUS-AQ filed campaign, which was the simulation period, and land data including the Olympic Park data. CREATE 2015 and Clean Air Policy Support System (CAPSS) 2013 were used for Northeast and South Korean anthropogenic emissions. The modeled mean PM2.5 concentration in CN was about 27.8 ㎍/㎥ during the period. Modeled contributions of CN's coal-fired power plant emissions to Seoul, Incheon, and the Gyeonggi-do area was 0.15㎍/㎥, 0.03㎍/㎥, and 0.16㎍/㎥, respectively during the episode.

  2. A decision support system for water supply in watersheds with recurrent wildfires

    NASA Astrophysics Data System (ADS)

    Santos, Regina; Fernandes, Luís; Pereira, Mário; Cortes, Rui; Pacheco, Fernando

    2015-04-01

    The Beça River basin (North of Portugal) is barely affected by anthropogenic pressures, namely by the harmful effects of industrialization, urbanization or intensive agriculture. However, this basin is subject to recurrent wildfires, which plays a major role on soil erosion and water quality deterioration. Wildfires are responsible for increasing the concentration of soil nitrogen (N) and phosphorous (P) that ultimately arise in the rivers and water reservoirs as a result of transport by rainfall. In this sense, the main aims of this study are threefold: (i) to assess the relationship between fire occurrence and P concentration in river water, (ii) to model the P and N concentrations in stream water at the basin and sub-basin scales, and (iii) to propose management guidelines for the protection of drinking water resources taking into account the local history on forest fires. This study includes morphological, hydrological and climatological characterization of the study area as well as the spatial-temporal distribution of the fire incidence in the basin. The rainfall-runoff and nutrient transport processes were performed respectively with Mike Hydro Basin and the ECO Lab. The data requirements for these analysis/tools includes: a digital elevation model, Corine Land Cover maps (for 1990, 2000 and 2006), cartography of burned areas (covering the period 1990 - 2013) and wildfire risk (assessed in 2011), daily records of temperature, precipitation and stream flow, measured at monitoring stations (during the 1990 - 2006 period). Obtained results reveals a maximum fire recurrence of 5 times during the study period (1990 - 2013) and robust exponential regression observed between burned area and wildfire risk (R2 > 0.9). The biophysical parameters contributes to 86% of the fire risk which suggest that burnt area in the Beça River basin is essentially triggered by natural causes. A total of 16,396 ha was burned between 1990 and 2013, corresponding to 47% of the basin area which was covered by scrubs (69%), forests (22%) and heterogeneous agricultural areas (9%). A close relationship was found between the concentration of phosphorus in river water and the occurrence of forest fires. The annual and monthly phosphorus concentrations are influenced by the burned area and the river flow discharge. However, the hydrologic conditions prevail in the sense that, for similar values of burnt area, the maximum phosphorous concentration is higher in dry than in wet years. In addition, the phosphorus concentrations in the water bodies exceeded the limits imposed by the National and European legislation for good ecological status, human consumption and multiple uses mostly in last years of the study period. The fire frequency is a key variable in the planning and management of water bodies within a fire-prone watershed. The impacts of wildfires on water quality may become periodical instead of occasional as a consequence of the reduced precipitation and increased fire frequency and intensity projected for the near future climate. This work was supported by national funds by FCT - Portuguese Foundation for Science and Technology, under the project PEst-OE/AGR/UI4033/2014 and by the project SUSTAINSYS: Environmental Sustainable Agro-Forestry Systems (NORTE-07-0124-FEDER-000044), financed by the North Portugal Regional Operational Programme (ON.2 - O Novo Norte), under the National Strategic Reference Framework (QREN), through the European Regional Development Fund (FEDER), as well as by National Funds (PIDDAC) through the Portuguese Foundation for Science and Technology (FCT/MEC).

  3. Modeling acute respiratory illness during the 2007 San Diego wildland fires using a coupled emissions-transport system and generalized additive modeling

    PubMed Central

    2013-01-01

    Background A study of the impacts on respiratory health of the 2007 wildland fires in and around San Diego County, California is presented. This study helps to address the impact of fire emissions on human health by modeling the exposure potential of proximate populations to atmospheric particulate matter (PM) from vegetation fires. Currently, there is no standard methodology to model and forecast the potential respiratory health effects of PM plumes from wildland fires, and in part this is due to a lack of methodology for rigorously relating the two. The contribution in this research specifically targets that absence by modeling explicitly the emission, transmission, and distribution of PM following a wildland fire in both space and time. Methods Coupled empirical and deterministic models describing particulate matter (PM) emissions and atmospheric dispersion were linked to spatially explicit syndromic surveillance health data records collected through the San Diego Aberration Detection and Incident Characterization (SDADIC) system using a Generalized Additive Modeling (GAM) statistical approach. Two levels of geographic aggregation were modeled, a county-wide regional level and division of the county into six sub regions. Selected health syndromes within SDADIC from 16 emergency departments within San Diego County relevant for respiratory health were identified for inclusion in the model. Results The model captured the variability in emergency department visits due to several factors by including nine ancillary variables in addition to wildfire PM concentration. The model coefficients and nonlinear function plots indicate that at peak fire PM concentrations the odds of a person seeking emergency care is increased by approximately 50% compared to non-fire conditions (40% for the regional case, 70% for a geographically specific case). The sub-regional analyses show that demographic variables also influence respiratory health outcomes from smoke. Conclusions The model developed in this study allows a quantitative assessment and prediction of respiratory health outcomes as it relates to the location and timing of wildland fire emissions relevant for application to future wildfire scenarios. An important aspect of the resulting model is its generality thus allowing its ready use for geospatial assessments of respiratory health impacts under possible future wildfire conditions in the San Diego region. The coupled statistical and process-based modeling demonstrates an end-to-end methodology for generating reasonable estimates of wildland fire PM concentrations and health effects at resolutions compatible with syndromic surveillance data. PMID:24192051

  4. Modelling fire frequency and area burned across phytoclimatic regions in Spain using reanalysis data and the Canadian Fire Weather Index System

    NASA Astrophysics Data System (ADS)

    Bedia, J.; Herrera, S.; Gutiérrez, J. M.

    2013-09-01

    We develop fire occurrence and burned area models in peninsular Spain, an area of high variability in climate and fuel types, for the period 1990-2008. We based the analysis on a phytoclimatic classification aiming to the stratification of the territory into homogeneous units in terms of climatic and fuel type characteristics, allowing to test model performance under different climatic and fuel conditions. We used generalized linear models (GLM) and multivariate adaptive regression splines (MARS) as modelling algorithms and temperature, relative humidity, precipitation and wind speed, taken from the ERA-Interim reanalysis, as well as the components of the Canadian Forest Fire Weather Index (FWI) System as predictors. We also computed the standardized precipitation-evapotranspiration index (SPEI) as an additional predictor for the models of burned area. We found two contrasting fire regimes in terms of area burned and number of fires: one characterized by a bimodal annual pattern, characterizing the Nemoral and Oro-boreal phytoclimatic types, and another one exhibiting an unimodal annual cycle, with the fire season concentrated in the summer months in the Mediterranean and Arid regions. The fire occurrence models attained good skill in most of the phytoclimatic zones considered, yielding in some zones notably high correlation coefficients between the observed and modelled inter-annual fire frequencies. Total area burned also exhibited a high dependence on the meteorological drivers, although their ability to reproduce the observed annual burned area time series was poor in most cases. We identified temperature and some FWI system components as the most important explanatory variables, and also SPEI in some of the burned area models, highlighting the adequacy of the FWI system for fire modelling applications and leaving the door opened to the development a more complex modelling framework based on these predictors. Furthermore, we demonstrate the potential usefulness of ERA-Interim reanalysis data for the reconstruction of historical fire-climate relationships at the scale of analysis. Fire frequency predictions may provide a preferable basis for past fire history reconstruction, long-term monitoring and the assessment of future climate impacts on fire regimes across regions, posing several advantages over burned area as response variable.

  5. Acute toxicity of fire-retardant and foam-suppressant chemicals to yalella azteca (Saussure)

    USGS Publications Warehouse

    McDonald, Susan F.; Hamilton, Steven J.; Buhl, Kevin J.; Heisinger, James F.

    1997-01-01

    Acute toxicity tests were conducted with Hyalella azteca Saussure (an amphipod) exposed in soft and hard waters to three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F) and two foam suppressants (Phos-Chek WD-881 and Silv-Ex). The chemicals were slightly to moderately toxic to amphipods. The most toxic chemical to amphipods in soft and hard water was Phos-Chek WD-881 (96-h mean lethal concentration [LC50] equal to 10 mg/L and 22 mg/L, respectively), and the least toxic chemical to amphipods in soft water was Fire-Trol GTS-R (96-h LC50 equal to 127 mg/L) and in hard water was Fire-Trol LCG-R (96-h LC50 equal to 535 mg/L). Concentrations of ammonia in tests with the three fire retardants and both water types were greater than reported LC50 values and probably were the major toxic component. Estimated un-ionized ammonia concentrations near the LC50 were frequently less than the reported LC50 ammonia concentrations for amphipods. The three fire retardants were more toxic in soft water than in hard water even though ammonia and un-ionized ammonia concentrations were higher in hard water tests than in soft water tests. The accidental entry of fire-fighting chemicals into aquatic environments could adversely affect aquatic invertebrates, thereby disrupting ecosystem function.

  6. Trajectory and Concentration PM10 on Forest and Vegetation Peat-Fire HYSPLIT Model Outputs and Observations (Period: September - October 2015)

    NASA Astrophysics Data System (ADS)

    Khairullah; Effendy, S.; Makmur, E. E. S.

    2017-03-01

    Forest and vegetation peat-fire is one of the main sources of air pollution in Kalimantan, predominantly during the dry period. In 2015, forest and vegetation fire in Central Kalimantan and South Kalimantan emit large quantities of smoke leading to poor air quality. Haze is a phenomenon characterized by high concentration of particulate matter. This research objective is to analyze trajectory and dispersion of concentration particulate matter, PM10 in Banjarbaru and Palangka Raya. Dynamics of PM10 (Particulate matter less than or 10 µm in size) on vegetation peat-fire is done using GDAS (Global Data Assimilation System) output with a horizontal resolution 1º which corresponds to 100 km × 100 km for input model. Climate conditions in the period September to October 2015 at generally during dry season of El Nino year. The Hybrid-single Langrangian Integrated Trajectory (HYSPLIT) model was used to investigate concentration and long-range movement of this pollutant from the source to the receptor area. We used time-series data on PM10 readings obtained from two stations Banjarbaru (South Kalimantan) and Palangka Raya (Central Kalimantan) belonging to Meteorology Climatology and Geophysics Agency (BMKG). We also used weather parameter such as wind speed and direction. We investigated trajectory run from hotspots information MoF (Sipongi Output Programs) and HYSPLIT. We compared concentration obtained from PM10 observation and its concentrations trend. The dispersion pattern, as simulated by HYSPLIT showed that the distribution of PM10 was greatly influenced by the wind direction and topography. There is a large difference between the concentration of PM10 Palangka Raya and Banjarbaru.

  7. Indoor respirable particulate matter concentrations from an open fire, improved cookstove, and LPG/open fire combination in a rural Guatemalan community.

    PubMed

    Albalak, R; Bruce, N; McCracken, J P; Smith, K R; De Gallardo, T

    2001-07-01

    Improved biomass cookstoves have the potential to reduce pollutant emissions and thereby reduce pollution exposure among populations in developing countries who cook daily with biomass fuels. However, evaluation of such interventions has been very limited. This article presents results from a study carried out in 30 households in rural Guatemala. Twenty-four hour PM3.5 concentrations were compared over 8 months for three fuel/cookstove conditions (n = 10 households for each condition): a traditional open fire cookstove, an improved cookstove called the plancha mejorada, and a liquefied petroleum gas (LPG) stove/open fire combination. Twenty-four hour geometric mean PM3.5 concentrations were 1560 micrograms/m3 (n = 58; 95% C.I. 1310, 1850), 280 micrograms/m3 (n = 59; 95% C.I. 240-320), and 850 micrograms/m3 (n = 60; 95% C.I. 680-1050) for the open fire, plancha, and LPG/open fire combination, respectively. A generalized estimating equation model showed a 45% reduction in PM3.5 concentrations for the LPG/open fire combination as compared to the open fire alone. The difference approached significance (p < 0.0737). The plancha showed an 85% reduction in PM3.5 concentrations as compared to the open fire (p < 0.0001). An analysis of the interaction of time with stove type showed that the temporal trend in pollution did not significantly differ among the three stove types. The reduced PM3.5 concentrations were maintained over time. Season did not affect pollutant concentrations. Of the two interventions, the plancha appears to offer the best prospects for achieving substantial reductions in indoor air pollution levels, although issues of cost and stove maintenance remain to be addressed.

  8. The association of physical examination abnormalities and carboxyhemoglobin concentrations in 21 dogs trapped in a kennel fire.

    PubMed

    Ashbaugh, Elizabeth A; Mazzaferro, Elisa M; McKiernan, Brendan C; Drobatz, Kenneth J

    2012-06-01

    To evaluate physical examination findings and their association with carboxyhemoglobin (COHb) concentrations in 21 dogs that were exposed to smoke during a kennel fire. Twenty-one dogs were exposed to a kennel fire. Physical exam findings, presenting, and posttherapy COHb concentrations as well as therapeutic interventions were evaluated. COHb concentrations upon presentation were increased in all smoke inhalation exposed dogs. These dogs were compared to a small set of clinically normal staff-owned dogs who were not exposed to fire. Physical parameters significantly associated with higher COHb concentrations included lower body temperature, increased respiratory effort, abnormal respiratory auscultation, altered neurologic status, and length of hospital stay. Oxygen therapy resulted in a more rapid decline in COHb concentrations although 5 dogs still had mildly increased COHb concentrations 24-hour postadmission. This study describes the relationship of admitting clinical findings of dogs exposed to a kennel fire with their initial blood COHb concentrations. It also describes the resolution of increased COHb concentrations with use of oxygen therapy and hospitalization. Additionally, COHb concentrations for a control group of dogs was evaluated and compared to the dogs exposed to smoke inhalation. © Veterinary Emergency and Critical Care Society 2012.

  9. Impact of Wildfire on Solute Release in Forested Catchments, Jemez River, New Mexico, USA

    NASA Astrophysics Data System (ADS)

    Sanchez, R. A.; Meixner, T.; McIntosh, J. C.; Chorover, J.

    2017-12-01

    Wildfires represent a large disturbance to the hydrology and biogeochemistry of forested catchments. The number, size and severity of wildfires have significantly increased in the western United States since 1990. Nutrients and other elements (e.g. Ca) that were taken up and stored by biomass are released from burned vegetation during forest fires and transported downgradient via overland flow, shallow subsurface flow, and/or deep groundwater flow. Ash accumulations on hillslopes may also store particulate carbon and contain elevated concentrations of elements that maybe leached into surface and ground water over extended periods of time. In 2013, the Thompson Ridge wildfire burned headwater catchments in the Jemez River Basin Critical Zone Observatory (JRB-CZO) within the Valles Caldera National Preserve, New Mexico USA. The burn severity and area impacted were different in the three headwater catchments. This study investigated the impact of the wildfire on surface water quality, including how the fire-induced impacts evolved with time, and how biogeochemical processes controlled post-fire solute concentrations in the surface water. Comparison of pre- and post-fire surface water solute chemistry shows increases in major cations and anions following fire. Increases in nitrate and sulfate concentrations in streams after the wildfire were likely from leaching of burned biomass. The elevated NO3- and SO42- concentrations persisted for over two years, and were even higher during spring snowmelt. Meanwhile, base cation concentrations increased immediately, within a few weeks after the fire, likely related to leaching from combusted organic matter; and, over a period of approximately two months, base cation concentrations returned to pre-fire levels. Trace element behavior was also altered by fire. For example, while pre-fire aluminum concentrations in stream flow increased significantly during the wet seasons (snowmelt and monsoons), the post-fire observations do not show significant changes with increase in discharge.

  10. Acute toxicity of fire-control chemicals, nitrogenous chemicals, and surfactants to rainbow trout

    USGS Publications Warehouse

    Buhl, Kevin J.; Hamilton, Steven J.

    2000-01-01

    Laboratory studies were conducted to determine the acute toxicity of three ammonia-based fire retardants (Fire-Trol LCA-F, Fire-Trol LCM-R, and Phos-Chek 259F), five surfactant-based fire-suppressant foams (FireFoam 103B, FireFoam 104, Fire Quench, ForExpan S, and Pyrocap B-136), three nitrogenous chemicals (ammonia, nitrate, and nitrite), and two anionic surfactants (linear alkylbenzene sulfonate [LAS] and sodium dodecyl sulfate [SDS]) to juvenile rainbow trout Oncorhynchus mykiss in soft water. The descending rank order of toxicity (96-h concentration lethal to 50% of test organisms [96-h LC50]) for the fire retardants was as follows: Phos-Chek 259F (168 mg/L) > Fire-Trol LCA-F (942 mg/L) = Fire-Trol LCM-R (1,141 mg/L). The descending rank order of toxicity for the foams was as follows: FireFoam 103B (12.2 mg/L) = FireFoam 104 (13.0 mg/L) > ForExpan S (21.8 mg/L) > Fire Quench (39.0 mg/L) > Pyrocap B-136 [156 mg/L). Except for Pyrocap B-136, the foams were more toxic than the fire retardants. Un-ionized ammonia (NH3; 0.125 mg/L as N) was about six times more toxic than nitrite (0.79 mg/L NO2-N) and about 13,300 times more toxic than nitrate (1,658 mg/L NO3-N). Linear alkylbenzene sulfonate (5.0 mg/L) was about five times more toxic than SDS (24.9 mg/L). Estimated total ammonia and NH3 concentrations at the 96-h LC50s of the fire retardants indicated that ammonia was the primary toxic component in these formulations. Based on estimated anionic surfactant concentrations at the 96-h LC50s of the foams and reference surfactants, LAS was intermediate in toxicity and SDS was less toxic to rainbow trout when compared with the foams. Comparisons of recommended application concentrations to the test results indicate that accidental inputs of these chemicals into streams require substantial dilutions (100-1,750-fold to reach concentrations nonlethal to rainbow trout.

  11. Next generation fire suppressants

    NASA Technical Reports Server (NTRS)

    Brown, Jerry A.

    1995-01-01

    Spectrex, Inc., located in Cedar Grove, NJ is a manufacturer of fire detection and suppression equipment. Spectrex is one of the original pioneers in high speed fire detection and suppression systems for combat vehicles. Spectrex has installed fire suppressions systems in thousands of combat vehicles and ships throughout the world. Additionally, they manufacture flame explosion detectors, ship damage control systems, and optical gas and vapor detectors. The culmination of several years of research and development has recently produced an innovative electro-optical continuous monitoring systems called SharpEye 20/20I IR(sup 3) and SAFEYE that provide fast and reliable gas, vapor, aerosol, flame, and explosion detection. SharpEye 20/20I IR(sup 3) is a self-contained triple spectrum flame detector which scans for oscillating IR radiation (1 to 10 Hz) in the spectral bands ranging from 4.0 to 5.0 microns and uses programmed algorithms to check the ratio and correlation of data received by the three sensors to make the system highly immune to false alarms. It is extremely sensitive as it can detect a 1 x 1 square foot gasoline pan fire at 200 feet in less than 3 seconds. The sensitivity is user programmable, offering 4 ranges of detection. SAFEYE is comprised of a selected number of multispectral ban microprocessors controlled detectors which are in communication with one or more radiation sources that is projected along a 600 feet optical path. The signals from the selected narrow bands are processed and analyzed by highly sophisticated algorithms. It is ideal for high risk, remote, large areas such as petroleum and chemical manufacturing sites, waste dumps, aircraft cargo bays, and ship compartments. The SAFEYE will perform direct readings of the presence or rate of rise of concentrations of gases, vapors, or aerosols at the range of parts per million and provide alarms at various set points at different levels of concentrations.

  12. Novel approach for extinguishing large-scale coal fires using gas-liquid foams in open pit mines.

    PubMed

    Lu, Xinxiao; Wang, Deming; Qin, Botao; Tian, Fuchao; Shi, Guangyi; Dong, Shuaijun

    2015-12-01

    Coal fires are a serious threat to the workers' security and safe production in open pit mines. The coal fire source is hidden and innumerable, and the large-area cavity is prevalent in the coal seam after the coal burned, causing the conventional extinguishment technology difficult to work. Foams are considered as an efficient means of fire extinguishment in these large-scale workplaces. A noble foam preparation method is introduced, and an original design of cavitation jet device is proposed to add foaming agent stably. The jet cavitation occurs when the water flow rate and pressure ratio reach specified values. Through self-building foaming system, the high performance foams are produced and then infused into the blast drilling holes at a large flow. Without complicated operation, this system is found to be very suitable for extinguishing large-scale coal fires. Field application shows that foam generation adopting the proposed key technology makes a good fire extinguishment effect. The temperature reduction using foams is 6-7 times higher than water, and CO concentration is reduced from 9.43 to 0.092‰ in the drilling hole. The coal fires are controlled successfully in open pit mines, ensuring the normal production as well as the security of personnel and equipment.

  13. Fire feedbacks over geological time and the evolution of atmospheric oxygen concentration

    NASA Astrophysics Data System (ADS)

    Mills, B.; Belcher, C.; Lenton, T. M.

    2017-12-01

    During the 4.5 billion year history of the Earth, the concentration of oxygen in the atmosphere has risen from trace levels to today's 21%. Yet over the last 400 million years, O2 concentration appears to have remained within a relatively narrow range (around 15% - 30%), despite dramatic changes in the nature of global biogeochemical cycling. This stability has been crucial for continued animal evolution, and is thought to have arisen through feedbacks between oxygen, wildfire and plant productivity: the strong oxygen- dependence of fire initiation and spread means that global photosynthetic primary productivity is suppressed when oxygen levels are high, and enhanced when levels are low. We present biogeochemical modelling of the long term carbon and oxygen cycles, which aims to capture the operation of the wildfire feedback alongside other key processes. We find that wildfire can effectively stabilize long term oxygen concentrations, but that the nature of this feedback has changed as plant evolution has provided different fuels. Specifically, the evolution of early angiosperms during the Cretaceous period provided new understory fuels that more easily facilitated crown and canopy fires. Adding these dynamics to our model produces a more stable system over long timescales, and the model predicts that oxygen concentration has declined towards the present day - a prediction that is supported by other independent estimates.

  14. Determining the most effective concentration of cypermethrin and the appropriate carrier particle size for fire ant (Hymenoptera: Formicidae) bait.

    PubMed

    Kafle, Lekhnath; Shih, Cheng-Jen

    2012-03-01

    The purpose of this study was to determine the most effective particle size of DDGS (distiller's dried grains with solubles) as fire ant bait carrier, as well as the most effective concentration of cypermethrin as a toxicant against the red imported fire ant (RIFA) Solenopsis invicta Buren under laboratory conditions. The DDGS particle size did not affect the fire ant's preference for the bait, but it did affect the mass of DDGS being carried back to the nest. The size of the DDGS particles and the mass of DDGS being carried back to the nest were positively correlated. The most efficient particle size of DDGS was 0.8-2 mm. The concentration of cypermethrin has a specific range for killing fire ants in an efficient manner. Neither a very low nor a very high concentration of cypermethrin was able to kill fire ants efficiently. The most effective concentration of cypermethrin was 0.13% in DDGS when mixed with 15% shrimp shell powders and 11% soybean oil. Based on its ability to kill fire ants when mixed with cypermethrin, as well as the advantage of having a larger area coverage when sprayed in the field, DDGS as the carrier and cypermethrin as the toxicant can be considered to be an efficient way to prepare fire ant bait for controlling fire ants in infested areas. Copyright © 2012 Society of Chemical Industry.

  15. Mercury emission from coal seam fire at Wuda, Inner Mongolia, China

    NASA Astrophysics Data System (ADS)

    Liang, Yanci; Liang, Handong; Zhu, Shuquan

    2014-02-01

    The underground coal seam fire in the Wuda, Inner Mongolia of china is one of the most serious coal fires in the world with a history over 50 years and endangers the neighboring downwind urban area. To investigate the potential mercury emission and migration from the coal seam fire, in situ real-time measurement of total gaseous mercury (TGM) concentration using Lumex RA-915 + mercury analyzer were implemented on the fire zone and the urban area. The results show an average TGM concentration of 464 ng m-3 in the fumes released from surface vents and cracks on the fire zone, which leads to an elevated TGM concentration of 257 ng m-3 (211-375 ng m-3) in the near-surface air at the fire zone and 89 ng m-3 (23-211 ng m-3) at the peripheral area. The average TGM concentration in the adjoining downwind urban area of Wuda is 33 ng m-3. This result suggests that the coal seam fire may not only contribute to the global mercury inventory but also be a novel source for mercury pollution in the urban areas. The scenario of urban areas being adjacent to coal seam fires is not limited to Wuda but relatively common in northern China and elsewhere. Whether there are other cities under influence of coal seam fires merits further investigation.

  16. Residual susceptibility of the red imported fire ant (Hymenoptera: Formicidae) to four agricultural insecticides.

    PubMed

    Seagraves, Michael P; McPherson, Robert M

    2003-06-01

    The red imported fire ant, Solenopsis invicta Buren, is an abundant predator in cropping systems throughout its range. It has been documented to be an important predator of numerous crop pests, as well as being an agricultural pest itself. Information on the impact of insecticides on natural enemies such as fire ants is necessary for the integration of biological and chemical control tactics in an effective pest management program. Therefore, a residual vial bioassay was developed to determine the concentration-mortality responses of S. invicta workers to four commonly used insecticides: acephate, chlorpyrifos, methomyl and lambda-cyhalothrin. Fire ant workers showed a mortality response to serial dilutions to all four chemicals. Methomyl (LC50 0.04 microg/vial, fiducial limits 0.03-0.06) was the most toxic, followed by chlorpyrifos (LC50 0.11 microg/vial, fiducial limits 0.07-0.17) and acephate (LC50 0.76 microg/vial, fiducial limits 0.50-1.04). Of the chemicals assayed, it took a much higher concentration of lambda-cyhalothrin (LC50 2.30 microg/vial, fiducial limits 1.57-3.59) to kill 50% of the workers compared with the other three chemicals. The results of this study demonstrate the wide range in responses of fire ants to four insecticides that are labeled and commonly used on numerous agricultural crops throughout the United States. These results further suggest the possibility of using a discriminating dose of lambda-cyhalothrin to control the target pest species while conserving fire ants in the agricultural systems in which their predatory behavior is beneficial to the integrated pest management program.

  17. 30 CFR 75.341 - Direct-fired intake air heaters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... combustible materials from passing over the burner units. (e) If intake air heaters use liquefied fuel systems... measurement of the carbon monoxide concentration at the bottom of each shaft, slope, or in the drift opening... a carbon monoxide sensor that is calibrated with a known concentration of carbon monoxide and air at...

  18. Materials Science Research Rack-1 Fire Suppressant Distribution Test Report

    NASA Technical Reports Server (NTRS)

    Wieland, P. O.

    2002-01-01

    Fire suppressant distribution testing was performed on the Materials Science Research Rack-1 (MSRR-1), a furnace facility payload that will be installed in the U.S. Lab module of the International Space Station. Unlike racks that were tested previously, the MSRR-1 uses the Active Rack Isolation System (ARIS) to reduce vibration on experiments, so the effects of ARIS on fire suppressant distribution were unknown. Two tests were performed to map the distribution of CO2 fire suppressant throughout a mockup of the MSRR-1 designed to have the same component volumes and flowpath restrictions as the flight rack. For the first test, the average maximum CO2 concentration for the rack was 60 percent, achieved within 45 s of discharge initiation, meeting the requirement to reach 50 percent throughout the rack within 1 min. For the second test, one of the experiment mockups was removed to provide a worst-case configuration, and the average maximum CO2 concentration for the rack was 58 percent. Comparing the results of this testing with results from previous testing leads to several general conclusions that can be used to evaluate future racks. The MSRR-1 will meet the requirements for fire suppressant distribution. Primary factors that affect the ability to meet the CO2 distribution requirements are the free air volume in the rack and the total area and distribution of openings in the rack shell. The length of the suppressant flowpath and degree of tortuousness has little correlation with CO2 concentration. The total area of holes in the rack shell could be significantly increased. The free air volume could be significantly increased. To ensure the highest maximum CO2 concentration, the PFE nozzle should be inserted to the stop on the nozzle.

  19. Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: Fire Dynamics Simulator comparisons with measured data.

    PubMed

    Hu, L H; Fong, N K; Yang, L Z; Chow, W K; Li, Y Z; Huo, R

    2007-02-09

    Smoke and toxic gases, such as carbon monoxide, are the most fatal factors in fires. This paper models fire-induced smoke spread and carbon monoxide transportation in an 88m long channel by Fire Dynamics Simulator (FDS) with large eddy simulation (LES). FDS is now a well-founded fire dynamics computational fluid dynamic (CFD) program, which was developed by National Institute of Standards and Technology (NIST). Two full scale experiments with fire sizes of 0.75 and 1.6MW were conducted in this channel to validate the program. The spread of the fire-induced smoke flow together with the smoke temperature distribution along the channel, and the carbon monoxide concentration at an assigned position were measured. The FDS simulation results were compared with experimental data with fairly good agreement demonstrated. The validation work is then extended to numerically study the carbon monoxide concentration distribution, both vertically and longitudinally, in this long channel. Results showed that carbon monoxide concentration increase linearly with the height above the floor and decreases exponentially with the distance away from the fire source.

  20. Post-fire Water Quality Response and Associated Physical Drivers

    NASA Astrophysics Data System (ADS)

    Rust, A.; Saxe, S.; Hogue, T. S.; McCray, J. E.; Rhoades, C.

    2017-12-01

    The frequency and severity of forest fires is increasing across the western US. Wildfires are known to impact water quality in receiving waters; many of which are important sources of water supply. Studies on individual forest fires have shown an increase in total suspended solids, nutrient and metal concentrations and loading in receiving streams. The current research looks at a large number of fires across a broad region (Western United States) to identify typical water quality changes after fire and the physical characteristics that drive those responses. This presentation will overview recent development of an extensive database on post-fire water quality. Across 172 fires, we found that water quality changed significantly in one out of three fires up to five years after the event compared to pre-burn conditions. For basins with higher frequency data, it was evident that water quality changes were significant in the first three years following fire. In both the initial years following fire and five years after fire, concentrations and loading rates of dissolved nutrients such as nitrite, nitrate and orthophosphate and particulate forms of nutrients, total organic nitrogen, total nitrogen, total phosphate, and total phosphorus increase thirty percent of the time. Concentrations of some major dissolved ions and metals decrease, with increased post-fire flows, while total particulate concentrations increased; the flux of both dissolved and particulate forms increase in thirty percent of the fires over five years. Water quality change is not uniform across the studied watersheds. A second goal of this study is to identify physical characteristics of a watershed that drive water quality response. Specifically, we investigate the physical, geochemical, and climatological characteristics of watersheds that control the type, direction, and magnitude of water quality change. Initial results reveal vegetation recovery is a key driver in post-fire water quality response. Ultimately, improved understanding of post-fire response and related drivers will advance potential mitigation and treatment strategies as well as aid in the parametrization of post-fire models of water quality.

  1. A summary of the scientific literature on the effects of fire on the concentration of nutrients in surface waters

    USGS Publications Warehouse

    Ranalli, Anthony J.

    2004-01-01

    This paper provides a detailed review of the chemical changes that occur in soil during a fire, the pathways by which nutrients are transferred from soil to surface-water bodies following a fire, and the temporal and spatial effects of fires on the concentration of nutrients in surface-water bodies during and following a fire that have been reported in the scientific literature. Thirty-nine papers from the scientific literature that represent studies that (1) were done in a variety of environments (savannas, grasslands, temperate forests, alpine forests, and so forth); (2) had a range of sampling frequency and duration, such as during and immediately following a fire (from the start of fire to 1 year later), short-term sampling (from end of fire to 3 years later), and long term-sampling (sampling for greater than 3 years following a fire); and (3) incorporated watersheds with various burn intensities, severities, and histories were reviewed and summarized. The review of the scientific literature has revealed that measurable effects of fires on streamwater quality are most likely to occur if the fire was severe enough to burn large amounts of organic matter, if windy conditions were present during the fire, if heavy rain occurred following the fire, and if the fire occurred in a watershed with steep slopes and soils with little cation-exchange capacity. Measurable effects of fires on lake- and reservoir-water quality are most likely to occur if, in addition to the factors listed for streams, the lake or reservoir is oligotrophic or mesotrophic and the residence time of water in the lake or reservoir is short relative to the length of time elevated concentrations of nutrients occur in runoff. Knowledge of whether a lake or reservoir is nitrogen or phosphorus limited is important because eutrophication of nitrogen-limited lakes may occur following a fire due to increasing nitrogen:phosphorus ratios caused by prolonged increases of nitrogen concentrations, especially nitrate.

  2. Fires and Smoke Observed from the Earth Observing System MODIS Instrument: Products, Validation, and Operational Use

    NASA Technical Reports Server (NTRS)

    Kaufman, Y. J.; Ichoku, C.; Giglio, L.; Korontzi, S.; Chu, D. A.; Hao, W. M.; Justice, C. O.; Lau, William K. M. (Technical Monitor)

    2001-01-01

    The MODIS sensor, launched on NASA's Terra satellite at the end of 1999, was designed with 36 spectral channels for a wide array of land, ocean, and atmospheric investigations. MODIS has a unique ability to observe fires, smoke, and burn scars globally. Its main fire detection channels saturate at high brightness temperatures: 500 K at 4 microns and 400 K at 11 microns, which can only be attained in rare circumstances at the I kin fire detection spatial resolution. Thus, unlike other polar orbiting satellite sensors with similar thermal and spatial resolutions, but much lower saturation temperatures (e.g. AVHRR and ATSR), MODIS can distinguish between low intensity ground surface fires and high intensity crown forest fires. Smoke column concentration over land is for the first time being derived from the MOMS solar channels, extending from 0.41 microns to 2.1 microns. The smoke product has been provisionally validated both globally and regionally over southern Africa and central and south America. Burn scars are observed from MODIS even in the presence of smoke, using the 1.2 to 2.1 micron channels. MODIS burned area information is used to estimate pyrogenic emissions. A wide range of these fire and related products and validation are demonstrated for the wild fires that occurred in northwestern United States in the summer of 2000. The MODIS rapid response system and direct broadcast capability is being developed to enable users to obtain and generate data in near real time. It is expected that health and land management organizations will use these systems for monitoring the occurrence of fires and the dispersion of smoke within two to six hours after data acquisition.

  3. Automatic fire-extinguishing system for inhabited pressurized compartments of manned spacecraft

    NASA Astrophysics Data System (ADS)

    Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid

    2017-06-01

    There is an innovational fire-extinguishing technology implemented via equipage of inhabited pressurized modules of the space station "Mir" and compartments of the Russian segment of International space station by automatic fire extinguishing systems in an orbital flight. Fire-safety in inhabited pressurized compartments of spacecraft (further - InPC SC) became one of the most dangerous factors during an orbital flight after a number of fire-hazardous situations occurred in different countries during preparation and execution of spaceflights [1,2]. High fire-risk in InPC of manned SC is determined by the following specific peculiarities of a arrangement and usage conditions of these items: - atmosphere of inhabited compartments is considerably enriched with oxygen - up to 25-40%; - there are many structural non-metal materials (here and after - materials) in order to lower the weight of InPC SC, most part of these materials is combustible under a given concentration of oxygen (here and after - Cox) in the atmosphere of InPC SC; - ventilation flow (here and after - Vvf) under normal operation of ventilation means in InPC SC considerably increases a possibility of fast fire-spread in InPC. - inhabited pressurized compartments of SC are filled with electrical equipment, which elements during failures even in low-current circuits became fire sources in oxygen-rich atmosphere; - indoor spaces of inhabited pressurized compartments of SC, as a rule, have complicated figuration with isolated for usage of local fire extinguishing zones with elements of electrical devices.

  4. Fuelling the palaeoatmospheric oxygen debate: how much atmospheric oxygen is required for ignition and propagation of smouldering fires?

    NASA Astrophysics Data System (ADS)

    Belcher, Claire M.; Hadden, Rory; McElwain, Jennifer C.; Rein, Guillermo

    2010-05-01

    Fire is a natural process integral to ecosystems at a wide range of temporal and spatial scales and is a key driver of change in the Earth system. Fire has been a major influence on Earth's systems since the Carboniferous. Whilst, climate is considered the ultimate control on global vegetation, fire is now known to play a key role in determining vegetation structure and composition, such that many of the world's ecosystems can be considered fire-dependant. Products of fire include chars, soots and aromatic hydrocarbon species all of which can be traced in ancient through to modern sediments. Atmospheric oxygen has played a key role in the development of life on Earth, with the rise of oxygen in the Precambrian being closely linked to biological evolution. Variations in the concentration of atmospheric oxygen throughout the Phanerozoic are predicted from models based on geochemical cycling of carbon and sulphur. Such models predict that low atmospheric oxygen concentrations prevailed in the Mesozoic (251-65ma) and have been hypothesised to be the primary driver of at least two of the ‘big five' mass extinction events in the Phanerozoic. Here we assess the levels of atmospheric oxygen required to ignite a fire and infer the likely levels of atmospheric oxygen to support smouldering combustion. Smouldering fire dynamics and its effects on ecosystems are very different from flaming fires. Smouldering fires propagate slowly, are usually low in temperature and represent a flameless form of combustion. These fires creep through organic layers of forest ground and peat lands and are responsible for a large fraction of the total biomass consumed in wildfires globally and are also a major contributor of carbon dioxide to the atmosphere. Once ignited, they can persist for long periods of time (months, years) spreading over very extensive areas of forest and deep into soil. Smouldering fires are therefore, the oldest continuously burning fires on Earth. We have combined expertise from both the Earth science and fire engineering disciplines to develop realistic ignition mechanisms and measurements of fire propagation within different levels of atmospheric oxygen. We present data from experimental burns run in the fully controlled and realistic atmospheric environment of the UCD PÉAC facility. The burns are designed to develop our understanding of ignition of fires in the natural world. We have studied ignition and propagation of fire in peat, a natural and highly flammable substance. Peat samples of approximately 100mm by 100mm in cross section and 50mm in depth were exposed to an ignition source (~100W of electric power) for 30 minutes. Thermocouples were placed throughout the sample to measure temperature changes during the initial 30 minute ignition phase and in order to observe ignition of the peat, intensity of combustion and spread of the smouldering front within the different atmospheric oxygen settings. We show that ignition and propagation of smouldering in peat does not occur below 16% atmospheric oxygen and that smouldering combustion continues for long periods (~4 hours in the size sample used) at 18% atmospheric oxygen and above. This suggests that atmospheric levels above 16% atmospheric are required to allow ignition and propagation of smouldering fires and that frequent occurrences of wildfires might only be expected in the geological past when atmospheric levels were above 18% oxygen. Fires play an important role in Earth's biogeochemical cycles; this work suggests that fire feedbacks into the Earth system would likely have been suppressed during periods of low atmospheric oxygen.

  5. Effect of Spacecraft Environmental Variables on the Flammability of Fire Resistant Fabrics

    NASA Astrophysics Data System (ADS)

    Osorio, A. F.; Fernandez-Pello, C.; Takahashi, S.; Rodriguez, J.; Urban, D. L.; Ruff, G.

    2012-01-01

    Fire resistant fabrics are used for firefighter, racecar drivers as well as astronaut suits. However, their fire resistant characteristics depend on the environment conditions and require study. Particularly important is the response of these fabrics to elevated oxygen concentration environments and radiant heat from a source such as an adjacent fire. In this work, experiments using two fire resistant fabrics were conducted to study the effect of oxygen concentration, external radiant flux and oxidizer flow velocity in concurrent flame spread. Results show that for a given fabric the minimum oxygen concentration for flame spread depends strongly on the magnitude of the external radiant flux. At increased oxygen concentrations the external radiant flux required for flame spread decreases. Oxidizer flow velocity influences the external radiant flux only when the convective heat flux from the flame has similar values to the external radiant flux. The results of this work provide further understanding of the flammability characteristics of fire resistant fabrics in environments similar to those of future spacecrafts.

  6. Boreal ditched forest and peatland are more vulnerable to forest fire than unditched areas

    NASA Astrophysics Data System (ADS)

    Köhler, Stephan J.; Granath, Gustav; Landahl, Anna; Fölster, Jens

    2016-04-01

    During summer of 2014 the largest wildfire in Swedish modern history occurred. The fire was ignited in a forest close to the Swedish town Sala and incinerated a total of 14 000 ha. The frequency of wildfires is expected to increase, due to effects of climate change such as increased temperature and decreased precipitation during the summer months. Wildfires can have a considerable impact on aquatic ecosystems and previous studies of wildfires have shown elevated concentrations of nutrients, cat- and anions. The area of the fire mainly consists of forestland, peatland and lakes and has been affected by acidification and intensive forestry. To assess the fire severity and the effects on the water chemistry, the fire severity were analyzed and classified using aerial phtographs and high resolution LIDAR data. The analysis indicated that increased fire intensity caused increased fire severity and that drained forested areas were more vulnerable to fire than undrained peatland. Measurements of water chemistry were conducted at nine streams and ten lakes inside the affected area. At two sites sensors for multiple parameters were deployed. During the initial three months of the post-fire period large peaks of ammonia-N and sulphate were observed in the streams and in a majority of the lakes while DOC was suppressed. In one stream Gärsjöbäcken the median concentrations of ammonia-N were 79 times higher after the fire. Due to nitrification the elevated concentrations of ammonia-N-nitrogen caused elevated concentrations of nitrate-nitrogen. The initial peak of sulphate caused a drop in ANC but after the peak had past ANC increased due to elevated concentrations of base cations. Correlation analysis of fire severity and water chemistry indicated that the maximum concentrations of ammonia-N increased with severely burned canopies in drained forested peatlands and in scorched open peatland. In a future climate with increased dry spells extensive ditching operations in forested peatlands might be counterproductive as it promotes fire vulnerability even in cold boreal regions.

  7. Firing system modification to alter ash properties for reduction of deposition and slagging under low NOx firing conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, D.; Lewis, R.; Tobiasz, R.

    1998-12-31

    The composition and properties of ash formed during coal firing have a major impact on boiler performance. Higher ash content in the coal can mean higher costs associated with coal handling, transportation, ash removal and ash disposal along with higher costs due to the increased ash content`s deleterious effects on pulverizing, combustion and heat transfer. ABB C-E Services, Inc. has conducted research for many years on what might be done to minimize the adverse effects of ash on boiler performance. Recently, ABB C-E Services has studied the effects of firing system modifications on ash composition and properties and the effectmore » these firing system modifications have on overall furnace performance. The subject of this paper is the impact of the installation of the CFS Concentric Firing System on the propensity for boiler wall ash deposition. For this study, CFS yaw angles were varied and particle samples were collected at the waterwalls for the different yaw angles tested. These ash samples were analyzed for ash composition. The results showed that with a larger CFS yaw angle (the air stream directed more towards the boiler walls) the base/acid ratio, iron content and sulfur content of the particle samples collected at the waterwall were reduced. This effect is due to several contributing factors: (1) an oxidizing environment produced by injecting more air toward the walls; and (2) an aerodynamic change which impacts the particle combustion time/temperature history.« less

  8. Spatial and temporal variability of atmospheric mercury concentrations emitted from a coal-fired power plant in Mexico.

    PubMed

    García, Gilberto Fuentes; Álvarez, Humberto Bravo; Echeverría, Rodolfo Sosa; de Alba, Sergio Rosas; Rueda, Víctor Magaña; Dosantos, Ernesto Caetano; Cruz, Gustavo Vázquez

    2017-09-01

    Atmospheric mercury in the environment as a result of the consumption of fossil fuels, such as coal used in electricity generation, has gained increased attention worldwide because of its toxicity, atmospheric persistence, and bioaccumulation. Determining or predicting the concentration of this pollutant in ambient air is essential for determining sensitive areas requiring health protection. This study investigated the spatiotemporal variability of gaseous elemental mercury (GEM) concentrations and its dry deposition surrounding the Presidente Plutarco Elías Calles (CETEPEC) coal-fired power plant, located on Mexico's Pacific coast. The CALPUFF dispersion model was applied on the basis of the daily consumption of coal during 2013 for each generating unit in the power plant and considering the local scale. The established 300-ng/m 3 annual average risk factor considered by the U.S. Department of Health and Human Services (U.S. DHHS) and Integrated Risk Information System (IRIS) must not be exceeded to meet satisfactory air quality levels. An area of 65 × 60 km was evaluated, and the results show that the risk level for mercury vapor was not exceeded because the annual average concentration was 2.8 ng/m 3 . Although the predicted risk level was not exceeded, continuous monitoring studies of GEM and of particulates in the atmosphere, soil, and water may be necessary to identify the concentration of this pollutant, specifically that resulting from coal-fired power plants operated in environmental areas of interest in Mexico. The dry mercury deposition was low in the study area; according to the CALPUFF model, the annual average was 1.40E-2 ng/m 2 /sec. These results represent a starting point for Mexico's government to implement the Minamata Convention on Mercury, which Mexico signed in 2013. The obtained concentrations of mercury from a bigger coal-fired plant in Mexico, through the application of the CALPUFF dispersion model by the mercury emissions, are below the level recommended according to the US Department of Health and Human Services and Integrated Risk Information System. These results provide evidence of important progress in the planning and installation to the future of monitoring mercury stations in the area of interest.

  9. Acquisition Practices Used at United States Marine Corps Program Executive Officer Land Systems: Program Manager Medium and Heavy Tactical Vehicles

    DTIC Science & Technology

    2014-09-22

    2010, the Naval Air Warfare Center–Weapons Division, China Lake , California, tested commercial fire suppression systems for use in U.S. Marine Corps...review, the excessive concentrations of carbon monoxide, nitrous oxide, hydrogen cyanide , and the acid gases experienced during the Molotov...excessive concentration levels of carbon monoxide, nitrous oxide, hydrogen cyanide , and the acid gases were identified during the Molotov cocktail live

  10. Southern Forestry Smoke Management Guidebook

    Treesearch

    Hugh E. Mobley; [senior compiler

    1976-01-01

    A system for predicting and modifying smoke concentrations from prescription fires is introduced. While limited to particulate matter and the more typical southern fuels, the system is for both simple and complex applications. Forestrysmoke constituents, variables affecting smoke production and dispersion, and new methods for estimating available fuel are presented....

  11. Effect of Tundra Fires on Stream Chemistry in Alaska's Yukon-Kuskokwim Delta

    NASA Astrophysics Data System (ADS)

    Jimmie, J. A.; Mann, P. J.; Schade, J. D.; Natali, S.; Fiske, G.; Holmes, R. M.

    2017-12-01

    Surface air temperatures in the Arctic have been increasing at approximately twice the global average, contributing to myriad changes including shifting vegetation, thawing permafrost, and altered surface and groundwater hydrology. Wildfire frequency and intensity has also been increasing, and in summer 2015, more area burned in the Yukon-Kuskowkwim Delta than in the previous 64 years combined. We investigated the impact of tundra fire on stream water chemistry, and by extension, on the movement of nutrients and organic matter between terrestrial and aquatic ecosystems. Using a high-resolution Digital Elevation Model, we characterized the contributing sub-watershed area at each of our stream water sampling locations and calculated the percent of each sub-watershed that was burned in summer 2015. We found that nitrate, ammonium, and phosphate concentrations increased with burn area in a watershed, indicating that terrestrial inputs of these constituents to aquatic systems increased following fire. Patterns were less striking for dissolved organic carbon and dissolved organic nitrogen, but there was a positive relationship between burn area and the concentration of these constituents as well. These results highlight the significant impact of tundra fires on terrestrial-aquatic linkages in the Arctic, and suggest that these impacts may increase in the future if fire in Arctic and boreal regions continues to become more common.

  12. Contents and leachability of heavy metals (Pb, Cu, Sb, Zn, As) in soil at the Pantex firing range, Amarillo, Texas.

    PubMed

    Basunia, S; Landsberger, S

    2001-10-01

    Pantex firing range soil samples were analyzed for Pb, Cu, Sb, Zn, and As. One hundred ninety-seven samples were collected from the firing range and vicinity area. There was a lack of knowledge about the distribution of Pb in the firing range, so a random sampling with proportional allocation was chosen. Concentration levels of Pb and Cu in the firing range were found to be in the range of 11-4675 and 13-359 mg/kg, respectively. Concentration levels of Sb were found to be in the range of 1-517 mg/kg. However, the Zn and As concentration levels were close to average soil background levels. The Sn concentration level was expected to be higher in the Pantex firing range soil samples. However, it was found to be below the neutron activation analysis (NAA) detection limit of 75 mg/kg. Enrichment factor analysis showed that Pb and Sb were highly enriched in the firing range with average magnitudes of 55 and 90, respectively. Cu was enriched approximately 6 times more than the usual soil concentration levels. Toxicity characteristic leaching procedure (TCLP) was carried out on size-fractionated homogeneous soil samples. The concentration levels of Pb in leachates were found to be approximately 12 times higher than the U.S. Environmental Protection Agency (EPA) regulatory concentration level of 5 mg/L. Sequential extraction (SE) was also performed to characterize Pb and other trace elements into five different fractions. The highest Pb fraction was found with organic matter in the soil.

  13. Never say never. Negligible carboxyhemoglobin in the victim of a smoldering mattress fire.

    PubMed

    Walter, J E; Hirsch, C S; Zumwalt, R E

    1984-09-01

    For many years, a high blood carboxyhemoglobin concentration has been used as a criterion for determining that a victim of conflagration was alive in the fire. We report a case in which a man died from the combined effects of burns and hypertensive cardiovascular disease. He had a negligible blood carboxyhemoglobin concentration, but the environmental evidence and autopsy findings are indicative of life in the fire, which arose in a smoldering mattress. We conclude that uncritical, rigid adherence to the requirement that fire victims have high carboxyhemoglobin concentrations can be misleading.

  14. Managing the human component of fire regimes: lessons from Africa.

    PubMed

    Archibald, Sally

    2016-06-05

    Human impacts on fire regimes accumulated slowly with the evolution of modern humans able to ignite fires and manipulate landscapes. Today, myriad voices aim to influence fire in grassy ecosystems to different ends, and this is complicated by a colonial past focused on suppressing fire and preventing human ignitions. Here, I review available evidence on the impacts of people on various fire characteristics such as the number and size of fires, fire intensity, fire frequency and seasonality of fire in African grassy ecosystems, with the intention of focusing the debate and identifying areas of uncertainty. Humans alter seasonal patterns of fire in grassy systems but tend to decrease total fire emissions: livestock have replaced fire as the dominant consumer in many parts of Africa, and fragmented landscapes reduce area burned. Humans alter the season and time of day when fires occur, with important implications for fire intensity, tree-grass dynamics and greenhouse gas (GHG) emissions. Late season fires are more common when fire is banned or illegal: these later fires are far more intense but emit fewer GHGs. The types of fires which preserve human livelihoods and biodiversity are not always aligned with the goal of reducing GHG concentrations. Current fire management challenges therefore involve balancing the needs of a large rural population against national and global perspectives on the desirability of different types of fire, but this cannot happen unless the interests of all parties are equally represented. In the future, Africa is expected to urbanize and land use to intensify, which will imply different trajectories for the continent's fire regimes.This article is part of the themed issue 'The interaction of fire and mankind. © 2016 The Author(s).

  15. Managing the human component of fire regimes: lessons from Africa

    PubMed Central

    Archibald, Sally

    2016-01-01

    Human impacts on fire regimes accumulated slowly with the evolution of modern humans able to ignite fires and manipulate landscapes. Today, myriad voices aim to influence fire in grassy ecosystems to different ends, and this is complicated by a colonial past focused on suppressing fire and preventing human ignitions. Here, I review available evidence on the impacts of people on various fire characteristics such as the number and size of fires, fire intensity, fire frequency and seasonality of fire in African grassy ecosystems, with the intention of focusing the debate and identifying areas of uncertainty. Humans alter seasonal patterns of fire in grassy systems but tend to decrease total fire emissions: livestock have replaced fire as the dominant consumer in many parts of Africa, and fragmented landscapes reduce area burned. Humans alter the season and time of day when fires occur, with important implications for fire intensity, tree–grass dynamics and greenhouse gas (GHG) emissions. Late season fires are more common when fire is banned or illegal: these later fires are far more intense but emit fewer GHGs. The types of fires which preserve human livelihoods and biodiversity are not always aligned with the goal of reducing GHG concentrations. Current fire management challenges therefore involve balancing the needs of a large rural population against national and global perspectives on the desirability of different types of fire, but this cannot happen unless the interests of all parties are equally represented. In the future, Africa is expected to urbanize and land use to intensify, which will imply different trajectories for the continent's fire regimes. This article is part of the themed issue ‘The interaction of fire and mankind. PMID:27216516

  16. Quantifying Future PM2.5 and Associated Health Effects Due to Changes in US Wildfires

    NASA Astrophysics Data System (ADS)

    Pierce, J. R.; Val Martin, M.; Ford, B.; Zelasky, S.; Heald, C. L.; Li, F.; Lawrence, D. M.; Fischer, E. V.

    2017-12-01

    Fine particulate matter (PM2.5) from landscape fires has been shown to adversely affect visibility, air quality and and health across the US. Fire activity is strongly related to climate and human activities. Predictions based on climate scenarios and future land cover projections that consider socioeconomic development suggest that fire activity will rise dramatically over the next decades. As PM2.5 is associated with increased mortality and morbidity rates, increases in emissions from landscape fires may alter the health burden on the US population. Here we present an analysis of the changes in future wildfire activity and consequences for PM2.5 and health over the US from 2000 to 2100. We employ the global Community Earth System Model (CESM) with the IPCC RCP projections. Within CESM, we use a process-based global fire parameterization to project future climate-driven and human-caused fire emissions. From these simulations, we determine the current and future impact on PM2.5 concentrations and visibility for different regions of the US, and we also calculate the mortality attributable to PM2.5 and wildfire-specific PM2.5 using existing concentration-response functions. Results show that although total PM2.5 concentrations in the US are projected to be similar in 2100 as in 2000, the dominant source of PM2.5 will change. Under the RCP8.5 climate projection and SSP3 population projection, non-fire emissions (mostly anthropogenic) are projected to decrease, but PM2.5 from CONUS and non-US wildfires is projected to increase from approximately 20% of all PM2.5 in 2000 to 80% of all PM2.5 in 2100. Furthermore, although the US population is expected to decline between 2000 and 2100, the mortality attributable to wildfire smoke is expected to increase from 25,000 deaths per year in 2000 to 75,000 deaths per year in 2100.

  17. Temporal effects of prescribed burning on terpene production in Mediterranean pines.

    PubMed

    Valor, Teresa; Ormeño, Elena; Casals, Pere

    2017-12-01

    Prescribed burning is used to reduce fuel hazard but underburning can damage standing trees. The effect of burning on needle terpene storage, a proxy for secondary metabolism, in fire-damaged pines is poorly understood despite the protection terpenes confer against biotic and abiotic stressors. We investigated variation in needle terpene storage after burning in three Mediterranean pine species featuring different adaptations to fire regimes. In two pure-stands of Pinus halepensis Mill. and two mixed-stands of Pinus sylvestris L. and Pinus nigra ssp. salzmanni (Dunal) Franco, we compared 24 h and 1 year post-burning concentrations with pre-burning concentrations in 20 trees per species, and evaluated the relative contribution of tree fire severity and physiological condition (δ13C and N concentration) on temporal terpene dynamics (for mono- sesqui- and diterpenes). Twenty-four hours post-burning, monoterpene concentrations were slightly higher in P. halepensis than at pre-burning, while values were similar in P. sylvestris. Differently, in the more fire-resistant P. nigra monoterpene concentrations were lower at 24 h, compared with pre-burning. One year post-burning, concentrations were always lower compared with pre- or 24 h post-burning, regardless of the terpene group. Mono- and sesquiterpene variations were negatively related to pre-burning δ13C, while diterpene variations were associated with fire-induced changes in needle δ13C and N concentration. At both post-burning times, mono- and diterpene concentrations increased significantly with crown scorch volume in all species. Differences in post-burning terpene contents as a function of the pine species' sensitivity to fire suggest that terpenic metabolites could have adaptive importance in fire-prone ecosystems in terms of flammability or defence against biotic agents post-burning. One year post-burning, our results suggest that in a context of fire-induced resource availability, pines likely prioritize primary rather than secondary metabolism. Overall, this study contributes to the assessment of the direct and indirect effects of fire on pine terpene storage, providing valuable information about their vulnerability to biotic and abiotic stressors throughout time. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Fires in Indian hospitals: root cause analysis and recommendations for their prevention.

    PubMed

    Chowdhury, Kanchan

    2014-08-01

    There is an increase in the incidence of intraoperative fire in Indian hospitals. It is hypothesized that oxygen (O2) enrichment of air, is primarily responsible for most of the fires, particularly in intensive care units. As the amount of ignition energy needed to initiate fire reduces in the presence of higher O2 concentration, any heat or spark, may be the source of ignition when the air is O2-rich. The split air conditioner is the source of many such fires in the ICU, neonatal intensive care unit (NICU), and operating room (OR), though several other types of equipment used in hospitals have similar vulnerability. Indian hospitals need to make several changes in the arrangement of equipment and practice of handling O2 gas, as well as create awareness among hospital staff, doctors, and administrators. Recommendations for changes in system practice, which are in conformity with the National Fire Protection Association USA, are likely to be applicable in preventing fires at hospitals in all developing countries of the world with warm climates. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A numerical solution of the problem of crown forest fire initiation and spread

    NASA Astrophysics Data System (ADS)

    Marzaeva, S. I.; Galtseva, O. V.

    2018-05-01

    Mathematical model of forest fire was based on an analysis of known experimental data and using concept and methods from reactive media mechanics. The study takes in to account the mutual interaction of the forest fires and three-dimensional atmosphere flows. The research is done by means of mathematical modeling of physical processes. It is based on numerical solution of Reynolds equations for chemical components and equations of energy conservation for gaseous and condensed phases. It is assumed that the forest during a forest fire can be modeled as a two-temperature multiphase non-deformable porous reactive medium. A discrete analog for the system of equations was obtained by means of the control volume method. The developed model of forest fire initiation and spreading would make it possible to obtain a detailed picture of the variation in the velocity, temperature and chemical species concentration fields with time. Mathematical model and the result of the calculation give an opportunity to evaluate critical conditions of the forest fire initiation and spread which allows applying the given model for of means for preventing fires.

  20. Carboxyhemoglobin concentrations in flash fire victims: report of six simultaneous fire fatalities without elevated carboxyhemoglobin.

    PubMed

    Hirsch, C S; Bost, R O; Gerber, S R; Cowan, M E; Adelson, L; Sunshine, I

    1977-09-01

    Eight people died in a traffic accident involving a tractor-trailer and ten autos. The accident caused a series of flash fires from ruptured gas tanks. Complete autopsies established that six of the victims died exclusively from thermal trauma; none showed an elevated blood carboxyhemoglobin concentration. Flash fire victims are exceptions to the axiom that elevation of blood carboxyhemoglobin is a sine qua non for concluding that a decedent recovered from the scene of a conflagration was alive in the fire.

  1. Projecting climate-driven increases in North American fire activity

    NASA Astrophysics Data System (ADS)

    Wang, D.; Morton, D. C.; Collatz, G. J.

    2013-12-01

    Climate regulates fire activity through controls on vegetation productivity (fuels), lightning ignitions, and conditions governing fire spread. In many regions of the world, human management also influences the timing, duration, and extent of fire activity. These coupled interactions between human and natural systems make fire a complex component of the Earth system. Satellite data provide valuable information on the spatial and temporal dynamics of recent fire activity, as active fires, burned area, and land cover information can be combined to separate wildfires from intentional burning for agriculture and forestry. Here, we combined satellite-derived burned area data with land cover and climate data to assess fire-climate relationships in North America between 2000-2012. We used the latest versions of the Global Fire Emissions Database (GFED) burned area product and Modern-Era Retrospective Analysis for Research and Applications (MERRA) climate data to develop regional relationships between burned area and potential evaporation (PE), an integrated dryness metric. Logistic regression models were developed to link burned area with PE and individual climate variables during and preceding the fire season, and optimal models were selected based on Akaike Information Criterion (AIC). Overall, our model explained 85% of the variance in burned area since 2000 across North America. Fire-climate relationships from the era of satellite observations provide a blueprint for potential changes in fire activity under scenarios of climate change. We used that blueprint to evaluate potential changes in fire activity over the next 50 years based on twenty models from the Coupled Model Intercomparison Project Phase 5 (CMIP5). All models suggest an increase of PE under low and high emissions scenarios (Representative Concentration Pathways (RCP) 4.5 and 8.5, respectively), with largest increases in projected burned area across the western US and central Canada. Overall, near-term climate projections point to pronounced changes in fire season length, total burned area, and the frequency of extreme events across North America by 2050.

  2. Soil Data from a Moderately Well and Somewhat Poorly Drained Fire Chronosequence near Thompson, Manitoba, Canada

    USGS Publications Warehouse

    Manies, K.L.; Harden, J.W.; Veldhuis, Hugo; Trumbore, Sue

    2006-01-01

    The U.S. Geological Survey project Fate of Carbon in Alaskan Landscapes (FOCAL) is studying the effect of fire and soil drainage on soil carbon storage in the boreal forest. As such this group was invited to be a part of a NSF-funded project (Fire, Ecosystem and Succession - Experiment Boreal or FIRES-ExB) to study the carbon balance of sites that varied in age (time since fire) and soil drainage in the Thompson, Manitoba, Canada region. This report describes the location of our FIRES-ExB sampling sites as well as the procedures used to describe, sample, and analyze the soils. This report also contains data tables with sample related information including, but not limited to, field descriptions, bulk density, particle size distribution, moisture content, carbon (C) concentration, nitrogen (N) concentration, isotopic data for C, and major, minor and trace elemental concentration.

  3. Robust encoding of stimulus identity and concentration in the accessory olfactory system.

    PubMed

    Arnson, Hannah A; Holy, Timothy E

    2013-08-14

    Sensory systems represent stimulus identity and intensity, but in the neural periphery these two variables are typically intertwined. Moreover, stable detection may be complicated by environmental uncertainty; stimulus properties can differ over time and circumstance in ways that are not necessarily biologically relevant. We explored these issues in the context of the mouse accessory olfactory system, which specializes in detection of chemical social cues and infers myriad aspects of the identity and physiological state of conspecifics from complex mixtures, such as urine. Using mixtures of sulfated steroids, key constituents of urine, we found that spiking responses of individual vomeronasal sensory neurons encode both individual compounds and mixtures in a manner consistent with a simple model of receptor-ligand interactions. Although typical neurons did not accurately encode concentration over a large dynamic range, from population activity it was possible to reliably estimate the log-concentration of pure compounds over several orders of magnitude. For binary mixtures, simple models failed to accurately segment the individual components, largely because of the prevalence of neurons responsive to both components. By accounting for such overlaps during model tuning, we show that, from neuronal firing, one can accurately estimate log-concentration of both components, even when tested across widely varying concentrations. With this foundation, the difference of logarithms, log A - log B = log A/B, provides a natural mechanism to accurately estimate concentration ratios. Thus, we show that a biophysically plausible circuit model can reconstruct concentration ratios from observed neuronal firing, representing a powerful mechanism to separate stimulus identity from absolute concentration.

  4. The role of wildfires and forest succession in stream biogeochemistry within the continuous permafrost zone of Central Siberia

    NASA Astrophysics Data System (ADS)

    Prokushkin, Anatoly

    2016-04-01

    Wildfires transform boreal and subarctic forested landscapes leading to the changes in organic matter and inorganic nutrient turnover in terrestrial ecosystems. To get an insight to the fire effect on C fluxes and general hydrochemical characteristics of streams draining continuous permafrost terrains of Central Siberian Plateau (64o N 100o E), we have selected the chronosequence of basins (n = 17) which were severely affected by fires (>80% of basin area) in the time range from 1 to 116 years ago. Stream waters were sampled continuously during frost free seasons (May-September) of 2006-2015. Four streams have been equipped with water level, temperature and conductivity probes for continuous monitoring. The strongest negative effect of wildfires on dissolved organic carbon (DOC) concentrations in streams has occurred right after a fire event, and minimum mean annual concentrations of DOC appeared between 15 and 20 years elapsed after a fire. The most pronounced decrease in DOC concentrations during an annual cycle found in freshet period (May-June) and summer-fall storm events: differences of DOC concentrations among "intact" (>100 years after fire) and recent fire basins (<6 years) reached as much as 2-fold. Less differentiation among basins appears under lowflow conditions, as DOC-depleted solutes from deeper soil layers become dominating in stream flow. Following the post-fire forest recovery, the seasonal mean DOC concentrations in streams demonstrated linear growth at the rate of ca. 0.11 mgC/l/a and approached the initial values already after ca. 60 years after fire disturbance. An opposite trend (i.e. increasing load to streams after fire impact) was observed for dissolved inorganic carbon, major anions and cations. Sulfate was found to be a good tracer of fire affect as increased 200-fold in stream waters right after a fire and steady decreased at the rate [SO42-] = 3.65 x (year after fire)^-0.75 as terrestrial ecosystems were recovering after a fire. For study area, Na+ and Cl- in streams appear to be good indicators of permafrost degradation as they reflect talik formation and connection of a stream to underlying evaporitic deposits. While evidence of permafrost degradation is currently not apparent in the region, we expect increasing concentrations of Na+ and Cl- in streams of Central Siberian Plateau as permafrost degrades due to decreased fire return interval and warming temperatures. The generalized data of active layer thickness (ALT) within analyzed watersheds have demonstrated that fire-driven deepening of ALT results in increasing stream inorganic compounds concentrations. The inverse relationship found between DOC and ALT might be attributed to deeper infiltration of solutions, sorption of DOC on clay minerals, and an increasing rate of DOC microbiological mineralization to CO2 due to increased soil temperatures. Post-fire forest recovery and, particularly, the accumulation of organic mater in the moss-lichen layer and soil organic horizon on watersheds accounted for increasing mean DOC concentrations in the streams. In opposite, increased insulation of soils by organic matter accumulating on the soil surface leads to steadily decreasing ALT and constrains an infiltration of solutes to subsoil. As a result, inorganic solute loading to stream channels is tended to decrease during post-fire forest succession in permafrost affected terrains.

  5. Observation of Upper and Middle Tropospheric Clouds

    NASA Technical Reports Server (NTRS)

    Cox, Stephen K.

    1996-01-01

    The goal of this research has been to identify and describe the properties of climatically important cloud systems critically important to understanding their effects upon satellite remote sensing and the global climate. These goals have been pursued along several different but complementary lines of investigation: the design, construction, testing and application of instrumentation; the collection of data sets during Intensive Field Observation periods; the reduction and analysis of data collected during IFO's; and completion of research projects specifically designed to address important and timely research objectives. In the first year covered by this research proposal, three papers were authored in the refereed literature which reported completed analyses of FIRE 1 IFO studies initiated under the previous NASA funding of this topic area. microphysical and radiative properties of marine stratocumulus cloud systems deduced from tethered balloon observations were reported from the San Nicolas Island site of the first FIRE marine stratocumulus experiment. Likewise, in situ observations of radiation and dynamic properties of a cirrus cloud layer were reported from first FIRE cirrus IFO based from Madison, Wisconsin. In addition, application techniques were under development for monitoring cirrus cloud systems using a 403 MHz Doppler wind profiler system adapted with a RASS (Radio Acoustic Sounding System) and an infrared interferometer system; these instrument systems were used in subsequent deployments for the FIRE 2 Parsons, Kansas and FIRE 2 Porto Santo, ASTEX expeditions. In November 1991 and in June 1992, these two systems along with a complete complement of surface radiation and meteorology measurements were deployed to the two sites noted above as anchor points for the respective IFO'S. Subsequent research activity concentrated on the interpretation and integration of the IFO analyses in the context of the radiative properties of cloud systems and our ability to remotely observe radiative, thermodynamic and dynamic properties of these cloud systems.

  6. Dilution-based emissions sampling from stationary sources: Part 2--Gas-fired combustors compared with other fuel-fired systems.

    PubMed

    England, Glenn C; Watson, John G; Chow, Judith C; Zielinska, Barbara; Chang, M C Oliver; Loos, Karl R; Hidy, George M

    2007-01-01

    With the recent focus on fine particle matter (PM2.5), new, self-consistent data are needed to characterize emissions from combustion sources. Such data are necessary for health assessment and air quality modeling. To address this need, emissions data for gas-fired combustors are presented here, using dilution sampling as the reference. The dilution method allows for collection of emitted particles under conditions simulating cooling and dilution during entry from the stack into the air. The sampling and analysis of the collected particles in the presence of precursor gases, SO2 nitrogen oxide, volatile organic compound, and NH3 is discussed; the results include data from eight gas fired units, including a dual-fuel institutional boiler and a diesel engine powered electricity generator. These data are compared with results in the literature for heavy-duty diesel vehicles and stationary sources using coal or wood as fuels. The results show that the gas-fired combustors have very low PM2.5 mass emission rates in the range of approximately 10(-4) lb/million Btu (MMBTU) compared with the diesel backup generator with particle filter, with approximately 5 x 10(-3) lb/MMBTU. Even higher mass emission rates are found in coal-fired systems, with rates of approximately 0.07 lb/MMBTU for a bag-filter-controlled pilot unit burning eastern bituminous coal. The characterization of PM2.5 chemical composition from the gas-fired units indicates that much of the measured primary particle mass in PM2.5 samples is organic or elemental carbon and, to a much less extent, sulfate. Metal emissions are quite low compared with the diesel engines and the coal- or wood-fueled combustors. The metals found in the gas-fired combustor particles are low in concentration, similar in concentration to ambient particles. The interpretation of the particulate carbon emissions is complicated by the fact that an approximately equal amount of particulate carbon (mainly organic carbon) is found on the particle collector and a backup filter. It is likely that measurement artifacts, mostly adsorption of volatile organic compounds on quartz filters, are positively biasing "true" particulate carbon emission results.

  7. An information theoretic model of information processing in the Drosophila olfactory system: the role of inhibitory neurons for system efficiency.

    PubMed

    Faghihi, Faramarz; Kolodziejski, Christoph; Fiala, André; Wörgötter, Florentin; Tetzlaff, Christian

    2013-12-20

    Fruit flies (Drosophila melanogaster) rely on their olfactory system to process environmental information. This information has to be transmitted without system-relevant loss by the olfactory system to deeper brain areas for learning. Here we study the role of several parameters of the fly's olfactory system and the environment and how they influence olfactory information transmission. We have designed an abstract model of the antennal lobe, the mushroom body and the inhibitory circuitry. Mutual information between the olfactory environment, simulated in terms of different odor concentrations, and a sub-population of intrinsic mushroom body neurons (Kenyon cells) was calculated to quantify the efficiency of information transmission. With this method we study, on the one hand, the effect of different connectivity rates between olfactory projection neurons and firing thresholds of Kenyon cells. On the other hand, we analyze the influence of inhibition on mutual information between environment and mushroom body. Our simulations show an expected linear relation between the connectivity rate between the antennal lobe and the mushroom body and firing threshold of the Kenyon cells to obtain maximum mutual information for both low and high odor concentrations. However, contradicting all-day experiences, high odor concentrations cause a drastic, and unrealistic, decrease in mutual information for all connectivity rates compared to low concentration. But when inhibition on the mushroom body is included, mutual information remains at high levels independent of other system parameters. This finding points to a pivotal role of inhibition in fly information processing without which the system efficiency will be substantially reduced.

  8. Energy consumption and energy-saving potential analysis of pollutant abatement systems in a 1000MW coal-fired power plant.

    PubMed

    Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S

    2018-05-10

    The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.

  9. Risk of large-scale fires in boreal forests of Finland under changing climate

    NASA Astrophysics Data System (ADS)

    Lehtonen, I.; Venäläinen, A.; Kämäräinen, M.; Peltola, H.; Gregow, H.

    2016-01-01

    The target of this work was to assess the impact of projected climate change on forest-fire activity in Finland with special emphasis on large-scale fires. In addition, we were particularly interested to examine the inter-model variability of the projected change of fire danger. For this purpose, we utilized fire statistics covering the period 1996-2014 and consisting of almost 20 000 forest fires, as well as daily meteorological data from five global climate models under representative concentration pathway RCP4.5 and RCP8.5 scenarios. The model data were statistically downscaled onto a high-resolution grid using the quantile-mapping method before performing the analysis. In examining the relationship between weather and fire danger, we applied the Canadian fire weather index (FWI) system. Our results suggest that the number of large forest fires may double or even triple during the present century. This would increase the risk that some of the fires could develop into real conflagrations which have become almost extinct in Finland due to active and efficient fire suppression. However, the results reveal substantial inter-model variability in the rate of the projected increase of forest-fire danger, emphasizing the large uncertainty related to the climate change signal in fire activity. We moreover showed that the majority of large fires in Finland occur within a relatively short period in May and June due to human activities and that FWI correlates poorer with the fire activity during this time of year than later in summer when lightning is a more important cause of fires.

  10. Airborne contaminants during controlled residential fires.

    PubMed

    Fent, Kenneth W; Evans, Douglas E; Babik, Kelsey; Striley, Cynthia; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin P

    2018-05-01

    In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21 st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (post suppression) and on the fireground where personnel were operating without any respiratory protection. Personal air measurements were collected from firefighters assigned to fire attack, victim search, overhaul, outside ventilation, and command/pump operator positions. Two different fire attack tactics were conducted for the fires (6 interior and 6 transitional) and exposures were compared between the tactics. For each of the 12 fires, firefighters were paired up to conduct each job assignment, except for overhaul that was conducted by 4 firefighters. Sampled compounds included polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs, e.g., benzene), hydrogen cyanide (HCN), and particulate (area air sampling only). Median personal air concentrations for the attack and search firefighters were generally well above applicable short-term occupational exposure limits, with the exception of HCN measured from search firefighters. Area air concentrations of all measured compounds decreased after suppression. Personal air concentrations of total PAHs and benzene measured from some overhaul firefighters exceeded exposure limits. Median personal air concentrations of HCN (16,300 ppb) exceeded the exposure limit for outside vent firefighters, with maximum levels (72,900 ppb) higher than the immediately dangerous to life and health (IDLH) level. Median air concentrations on the fireground (including particle count) were above background levels and highest when collected downwind of the structure and when ground-level smoke was the heaviest. No statistically significant differences in personal air concentrations were found between the 2 attack tactics. The results underscore the importance of wearing self-contained breathing apparatus when conducting overhaul or outside ventilation activities. Firefighters should also try to establish command upwind of the structure fire, and if this cannot be done, respiratory protection should be considered.

  11. The impact of fire on the Late Paleozoic Earth system

    PubMed Central

    Glasspool, Ian J.; Scott, Andrew C.; Waltham, David; Pronina, Natalia; Shao, Longyi

    2015-01-01

    Analyses of bulk petrographic data indicate that during the Late Paleozoic wildfires were more prevalent than at present. We propose that the development of fire systems through this interval was controlled predominantly by the elevated atmospheric oxygen concentration (p(O2)) that mass balance models predict prevailed. At higher levels of p(O2), increased fire activity would have rendered vegetation with high-moisture contents more susceptible to ignition and would have facilitated continued combustion. We argue that coal petrographic data indicate that p(O2) rather than global temperatures or climate, resulted in the increased levels of wildfire activity observed during the Late Paleozoic and can, therefore, be used to predict it. These findings are based upon analyses of charcoal volumes in multiple coals distributed across the globe and deposited during this time period, and that were then compared with similarly diverse modern peats and Cenozoic lignites and coals. Herein, we examine the environmental and ecological factors that would have impacted fire activity and we conclude that of these factors p(O2) played the largest role in promoting fires in Late Paleozoic peat-forming environments and, by inference, ecosystems generally, when compared with their prevalence in the modern world. PMID:26442069

  12. The impact of fire on the Late Paleozoic Earth system.

    PubMed

    Glasspool, Ian J; Scott, Andrew C; Waltham, David; Pronina, Natalia; Shao, Longyi

    2015-01-01

    Analyses of bulk petrographic data indicate that during the Late Paleozoic wildfires were more prevalent than at present. We propose that the development of fire systems through this interval was controlled predominantly by the elevated atmospheric oxygen concentration (p(O2)) that mass balance models predict prevailed. At higher levels of p(O2), increased fire activity would have rendered vegetation with high-moisture contents more susceptible to ignition and would have facilitated continued combustion. We argue that coal petrographic data indicate that p(O2) rather than global temperatures or climate, resulted in the increased levels of wildfire activity observed during the Late Paleozoic and can, therefore, be used to predict it. These findings are based upon analyses of charcoal volumes in multiple coals distributed across the globe and deposited during this time period, and that were then compared with similarly diverse modern peats and Cenozoic lignites and coals. Herein, we examine the environmental and ecological factors that would have impacted fire activity and we conclude that of these factors p(O2) played the largest role in promoting fires in Late Paleozoic peat-forming environments and, by inference, ecosystems generally, when compared with their prevalence in the modern world.

  13. Impact of wildfire on levels of mercury in forested watershed systems - Voyageurs National Park, Minnesota

    USGS Publications Warehouse

    Woodruff, Laurel G.; Sandheinrich, Mark B.; Brigham, Mark E.; Cannon, William F.

    2009-01-01

    Atmospheric deposition of mercury to remote lakes in mid-continental and eastern North America has increased approximately threefold since the mid-1800s (Swain and others, 1992; Fitzgerald and others, 1998; Engstrom and others, 2007). As a result, concerns for human and wildlife health related to mercury contamination have become widespread. Despite an apparent recent decline in atmospheric deposition of mercury in many areas of the Upper Midwest (Engstrom and Swain, 1997; Engstrom and others, 2007), lakes in which fish contain levels of mercury deemed unacceptable for human consumption and possibly unacceptable for fish-consuming wildlife are being detected with increasing frequency. In northern Minnesota, Voyageurs National Park (VNP) (fig. 1) protects a series of southern boreal lakes and wetlands situated on bedrock of the Precambrian Canadian Shield. Mercury contamination has become a significant resource issue within VNP as high concentrations of mercury in loons, bald eagle eaglets, grebes, northern pike, and other species of wildlife and fish have been found. The two most mercury-contaminated lakes in Minnesota, measured as methylmercury in northern pike (Esox lucius), are in VNP. Recent multidisciplinary U.S. Geological Survey (USGS) research demonstrated that the bulk of the mercury in lake waters, soils, and fish in VNP results from atmospheric deposition (Wiener and others, 2006). The study by Wiener and others (2006) showed that the spatial distribution of mercury in watershed soils, lake waters, and age-1 yellow perch (Perca flavescens) within the Park was highly variable. The majority of factors correlated for this earlier study suggested that mercury concentrations in lake waters and age-1 yellow perch reflected the influence of ecosystem processes that affected within-lake microbial production and abundance of methylmercury (Wiener and others, 2006), while the distribution of mercury in watershed soils seemed to be partially dependent on forest disturbance, especially the historic forest fire pattern (Woodruff and Cannon, 2002). Forest fire has an essential role in the forest ecosystems of VNP (Heinselman, 1996). Because resource and land managers need to integrate both natural wildfire and prescribed fire in management plans, the potential influence of fire on an element as sensitive to the environment as mercury becomes a critical part of their decisionmaking. A number of recent studies have shown that while fire does have a significant impact on mercury at the landscape level, the observed effects of fire on aquatic environments are highly variable and unpredictable (Caldwell and others, 2000; Garcia and Carrigan, 2000; Kelly and others, 2006; Nelson and others, 2007). Caldwell and others (2000) described an increase in methylmercury in reservoir sediments resulting from mobilization and transport of charred vegetative matter following a fire in New Mexico. Krabbenhoft and Fink (2000) attributed increases in total mercury concentrations in young-of-the-year fish in the Florida Everglades to release of mercury resulting from peat oxidation following fires. A fivefold increase in whole-body mercury accumulation by rainbow trout (Oncorhynchus mykiss) following a fire in Alberta, Canada, apparently resulted from increased nutrient concentrations that enhanced productivity and restructured the food web of a lake within the fire's burn footprint (Kelly and others, 2006). For this study, we determined the short-term effects of forest fire on mercury concentrations in terrestrial and aquatic environments in VNP by comparing and contrasting mercury concentrations in forest soils, lake waters, and age-1 yellow perch for a burned watershed and an adjacent lake, with similar samples from watersheds and lakes with no fire activity (control watersheds and lakes). The concentration of total mercury in whole, 1-year-old yellow perch serves as a good biological indicator for monitoring trends in methylmercury conce

  14. Impact of forest fires on the concentrations of polychlorinated dibenzo-p-dioxin and dibenzofurans in coastal waters of central Chile.

    PubMed

    Salamanca, Marco; Chandía, Cristian; Hernández, Aldo

    2016-12-15

    The relationship between the occurrence of forest fires in central Chile and the total concentration of dioxins and furans (PCDD/F) in nearby coastal waters was analyzed. The data for this analysis was obtained from a long-term environmental monitoring program (PROMNA) in the Bio-Bio Region. Quantification of PCDD/F was performed using HRGC/HRMS at the MSS laboratory in England. Between 2006 and 2014, peaks were observed in February 2007 and 2012. These concentration maxima coincided with major forest fires in the Bio-Bio Region and particularly with those in the Itata River Basin. The January 2012 fires generated an intense short-term response that was associated with atmospheric transport which increases medium toxicity furan-type congeners concentrations (TCDF, PCDF and HxCDF) and six months later a concentration increase of low toxicity dioxin-type congeners was observed (OCDD, HpCDD and HxCDD) coinciding with maximum winter river flow. These results suggest that forest fires near the coastal zone are responsible for increases in PCDD/F concentration observed in the study area. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Modelling Middle Infrared Thermal Imagery from Observed or Simulated Active Fire

    NASA Astrophysics Data System (ADS)

    Paugam, R.; Gastellu-Etchegorry, J. P.; Mell, W.; Johnston, J.; Filippi, J. B.

    2016-12-01

    The Fire Radiative Power (FRP) is used in the atmospheric and fire communities to estimate fire emission. For example, the current version of the emission inventory GFAS is using FRP observation from the MODIS sensors to derive daily global distribution of fire emissions. Although the FRP product is widely accepted, most of its theoretical justifications are still based on small scale burns. When up-scaling to large fires effects of view angle, canopy cover, or smoke absorption are still unknown. To cover those questions, we are building a system based on the DART radiative transfer model to simulate the middle infrared radiance emitted by a propagating fire front and propagating in the surrounding scene made of ambient vegetation and plume aerosols. The current version of the system was applied to fire ranging from a 1m2 to 7ha. The 3D fire scene used as input in DART is made of the flame, the vegetation (burnt and unburnt), and the plume. It can be either set up from [i] 3D physical based model scene (ie WFDS, mainly applicable for small scale burn), [ii] coupled 2D fire spread - atmospheric models outputs (eg ForeFire-MesoNH) or [iii] derived from thermal imageries observations (here plume effects are not considered). In the last two cases, as the complexity of physical processes occurring in the flame (in particular soot formation and emission) is not to solved, the flames structures are parameterized with (a) temperature and soot concentration based on empirical derived profiles and (b) 3D triangular shape hull interpolated at the fire front location. Once the 3D fire scene is set up, DART is then used to render thermal imageries in the middle infrared. Using data collected from burns conducted at different scale, the modelled thermal imageries are compared against observations, and effects of view angle are discussed.

  16. Grizzly Gulch Fire, South Dakota

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Burning next door to the South Dakota towns of Deadwood and Lead, the Grizzly Gulch fire forced the evacuation of many residents in the first week of July, 2002. In addition, smoke closed many of the roads in the area. At the time the fire's behavior was extreme, with 'torching, spotting, and running.' In other words, the fire was primarily burning along the ground, with entire trees occasionally erupting into flame (torching). At the same time, burning embers were being thrown ahead of the fire (spotting). In some areas the fire was spreading from the crown of one tree to another (running). (This glossary of fire terms has a good list of definitions) The above image shows the fire on the morning of July 1, 2002. Actively burning areas, concentrated on the east (right) side of the fire, are colored red and orange. Dark red areas indicate burn scars, while forest and other vegetation appears green. The exposed rock of the Homestake gold mine, now the National Underground Science Laboratory, is pinkish-brown. The total extent of the fire is oulined in yellow. The image was acquired by the Enhanced Thematic Mapper plus (ETM+) aboard the Landsat 7 satellite. More news about current wildfires in the United States is available from the National Fire Information Center. Image provided by the USGS EROS Data Center Satellite Systems Branch.

  17. 30 CFR 75.1324 - Methane concentration and tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methane concentration and tests. 75.1324... Methane concentration and tests. (a) No shot shall be fired in an area that contains 1.0 volume percent or more of methane. (b) Immediately before shots are fired, the methane concentration in a working place...

  18. 30 CFR 75.1324 - Methane concentration and tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Methane concentration and tests. 75.1324... Methane concentration and tests. (a) No shot shall be fired in an area that contains 1.0 volume percent or more of methane. (b) Immediately before shots are fired, the methane concentration in a working place...

  19. Evaluation of three percent Aqueous Film Forming Foam (AFFF) concentrates as fire fighting agents

    NASA Astrophysics Data System (ADS)

    Jablonski, E. J.

    1981-04-01

    A large-scale fire test program involving 20,000-square foot JP-4 fuel fires was conducted to evaluate the fire suppression effectiveness and compatibility of 3 percent Aqueous Film Forming Foam (AFFF) agents in Air Force fire fighting vehicles. Three commercially available 3 percent AFFF concentrates were tested in accordance with military specification MIL-F-24385B. Test results are summarized in Appendix A. As a result of these tests, an updated Revision C to this MIL SPEC has been accomplished with new requirements for both 3 percent and 6 percent AFFF extinguishing agents.

  20. Emissions of Selected Semivolatile Organic Chemicals from Forest and Savannah Fires.

    PubMed

    Wang, Xianyu; Thai, Phong K; Mallet, Marc; Desservettaz, Maximilien; Hawker, Darryl W; Keywood, Melita; Miljevic, Branka; Paton-Walsh, Clare; Gallen, Michael; Mueller, Jochen F

    2017-02-07

    The emission factors (EFs) for a broad range of semivolatile organic chemicals (SVOCs) from subtropical eucalypt forest and tropical savannah fires were determined for the first time from in situ investigations. Significantly higher (t test, P < 0.01) EFs (μg kg -1 dry fuel, gas + particle-associated) for polycyclic aromatic hydrocarbons (∑ 13 PAHs) were determined from the subtropical forest fire (7,000 ± 170) compared to the tropical savannah fires (1,600 ± 110), due to the approximately 60-fold higher EFs for 3-ring PAHs from the former. EF data for many PAHs from the eucalypt forest fire were comparable with those previously reported from pine and fir forest combustion events. EFs for other SVOCs including polychlorinated biphenyl (PCB), polychlorinated naphthalene (PCN), and polybrominated diphenyl ether (PBDE) congeners as well as some pesticides (e.g., permethrin) were determined from the subtropical eucalypt forest fire. The highest concentrations of total suspended particles, PAHs, PCBs, PCNs, and PBDEs, were typically observed in the flaming phase of combustion. However, concentrations of levoglucosan and some pesticides such as permethrin peaked during the smoldering phase. Along a transect (10-150-350 m) from the forest fire, concentration decrease for PCBs during flaming was faster compared to PAHs, while levoglucosan concentrations increased.

  1. Effects of a fire alarm strobe light on fecal corticosterone metabolite concentrations in mice.

    PubMed

    Godfrey, Denice; Silverman, Jerald

    2009-02-01

    The type and location of fire alarms are important considerations in animal facility design. The Guide for the Care and Use of Laboratory Animals recommends minimizing animal exposure to such alarms. Nevertheless, it is often necessary to maintain fire alarms within animal housing or procedural areas. The authors exposed male mice to the flashing strobe light component of a standard fire alarm and evaluated mouse fecal corticosterone concentration, which is known to be an indicator of stress. Mice were exposed to the strobe light for 5 min during either the light or the dark phase of the light:dark cycle. The authors collected fecal samples every 6 h for 24 h before exposing mice to the alarm and every 6 h for 24 h after exposure. Fecal samples taken before exposure (baseline samples) showed a normal circadian pattern of corticosterone metabolite excretion. In fecal samples taken after mice were exposed to the fire alarm, metabolite concentrations did not significantly differ from baseline concentrations over time.

  2. Effects of fire on composition, biomass, and nutrients in oak scrub vegetation on John F. Kennedy Space Center, Florida

    NASA Technical Reports Server (NTRS)

    Schmalzer, Paul A.; Hinkle, C. Ross

    1987-01-01

    Four stands of oak scrub two, four, eight, and 25 years since fire were sampled with permanent 15 m line transects. Percent cover by species was determined. Plant samples were analyzed for a variety of substances. Transects were resurveyed in 1985 for vegetation parameters. Nutrient pools in biomass were calculated from biomass data and tissue nutrient concentrations. Soil nutrient pools were calculated from nutrient concentrations and bulk density. Species distribution and soil chemical properties were found to be closely related to water table depth. The following fire-related conclusions are reached: (1) major structural changes occur in scrub after fire in that shrub height is reduced and requires four to six years to exceed 1 m; (2) reduction in shrub height affects the suitability of scrub for the Florida scrub jay (3) live biomass increases with time since fire; (4) nutrient concentrations in live biomass do not change with time since fire; (5) species composition and richness are little changed after fire; and (6) imposition of a continued regime of burning on a three-year cycle may have adverse impacts not indicated by the recovery of scrub from a single fire.

  3. Impacts of the Canadian forest fires on atmospheric mercury and carbonaceous particles in Northern New York.

    PubMed

    Wang, Yungang; Huang, Jiaoyan; Zananski, Tiffany J; Hopke, Philip K; Holsen, Thomas M

    2010-11-15

    The impact of Canadian forest fires in Quebec on May 31, 2010 on PM(2.5), carbonaceous species, and atmospheric mercury species was observed at three rural sites in northern New York. The results were compared with previous studies during a 2002 Quebec forest fire episode. MODIS satellite images showed transport of forest fire smoke from southern Quebec, Canada to northern New York on May 31, 2010. Back-trajectories were consistent with this regional transport. During the forest fire event, as much as an 18-fold increase in PM(2.5) concentration was observed. The concentrations of episode-related OC, EC, BC, UVBC, and their difference (Delta-C), reactive gaseous mercury (RGM), and particle-bound mercury (PBM) were also significantly higher than those under normal conditions, suggesting a high impact of Canadian forest fire emissions on air quality in northern New York. PBM, RGM, and Delta-C are all emitted from forest fires. The correlation coefficient between Delta-C and other carbonaceous species may serve as an indicator of forest fire smoke. Given the marked changes in PBM, it may serve as a more useful tracer of forest fires over distances of several hundred kilometers relative to GEM. However, the Delta-C concentration changes are more readily measured.

  4. Simulating smoke transport from wildland fires with a regional-scale air quality model: sensitivity to spatiotemporal allocation of fire emissions.

    PubMed

    Garcia-Menendez, Fernando; Hu, Yongtao; Odman, Mehmet T

    2014-09-15

    Air quality forecasts generated with chemical transport models can provide valuable information about the potential impacts of fires on pollutant levels. However, significant uncertainties are associated with fire-related emission estimates as well as their distribution on gridded modeling domains. In this study, we explore the sensitivity of fine particulate matter concentrations predicted by a regional-scale air quality model to the spatial and temporal allocation of fire emissions. The assessment was completed by simulating a fire-related smoke episode in which air quality throughout the Atlanta metropolitan area was affected on February 28, 2007. Sensitivity analyses were carried out to evaluate the significance of emission distribution among the model's vertical layers, along the horizontal plane, and into hourly inputs. Predicted PM2.5 concentrations were highly sensitive to emission injection altitude relative to planetary boundary layer height. Simulations were also responsive to the horizontal allocation of fire emissions and their distribution into single or multiple grid cells. Additionally, modeled concentrations were greatly sensitive to the temporal distribution of fire-related emissions. The analyses demonstrate that, in addition to adequate estimates of emitted mass, successfully modeling the impacts of fires on air quality depends on an accurate spatiotemporal allocation of emissions. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. A new website with real-time dissemination of information on fire activity and meteorological fire danger in Portugal

    NASA Astrophysics Data System (ADS)

    DaCamara, Carlos; Trigo, Ricardo; Nunes, Sílvia; Pinto, Miguel; Oliveira, Tiago; Almeida, Rui

    2017-04-01

    In Portugal, like in Mediterranean Europe, fire activity is a natural phenomenon linking climate, humans and vegetation and is therefore conditioned by natural and anthropogenic factors. Natural factors include topography, vegetation cover and prevailing weather conditions whereas anthropogenic factors encompass land management practices and fire prevention policies. Land management practices, in particular the inadequate use of fire, is a crucial anthropogenic factor that accounts for about 90% of fire ignitions. Fire prevention policies require adequate and timely information about wildfire potential assessment, which is usually based on fire danger rating systems that provide indices to be used on an operational and tactical basis in decision support systems. We present a new website designed to provide the user community with relevant real-time information on fire activity and meteorological fire danger that will allow adopting the adequate measures to mitigate fire damage. The fire danger product consists of forecasts of fire danger over Portugal based on a statistical procedure that combines information about fire history derived from the Fire Radiative Power product disseminated by the Land Surface Analysis Satellite Application Facility (LSA SAF) with daily meteorological forecasts provided by the European Centre for Medium-Range Weather Forecasts (ECMWF). The aim of the website is fourfold; 1) to concentrate all information available (databases and maps) relevant to fire management in a unique platform so that access by end users becomes easier, faster and friendlier; 2) to supervise the access of users to the different products available; 3) to control and assist the access to the platform and obtain feedbacks from users for further improvements; 4) to outreach the operational community and foster the use of better information that increase efficiency in risk management. The website is sponsored by The Navigator Company, a leading force in the global pulp and paper market. Since the operational start of the website, the number of registered users has been steadily increasing up to a total of 300 users from a wide community that encompasses forest managers, firemen and civil protection officers, personnel from municipalities, academic researchers and private owners.

  6. Solar-Heated and Cooled Office Building--Columbus, Ohio

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

  7. Advanced Fire Detector for Space Applications

    NASA Technical Reports Server (NTRS)

    Kutzner, Joerg

    2012-01-01

    A document discusses an optical carbon monoxide sensor for early fire detection. During the sensor development, a concept was implemented to allow reliable carbon monoxide detection in the presence of interfering absorption signals. Methane interference is present in the operating wavelength range of the developed prototype sensor for carbon monoxide detection. The operating parameters of the prototype sensor have been optimized so that interference with methane is minimized. In addition, simultaneous measurement of methane is implemented, and the instrument automatically corrects the carbon monoxide signal at high methane concentrations. This is possible because VCSELs (vertical cavity surface emitting lasers) with extended current tuning capabilities are implemented in the optical device. The tuning capabilities of these new laser sources are sufficient to cover the wavelength range of several absorption lines. The delivered carbon monoxide sensor (COMA 1) reliably measures low carbon monoxide levels even in the presence of high methane signals. The signal bleed-over is determined during system calibration and is then accounted for in the system parameters. The sensor reports carbon monoxide concentrations reliably for (interfering) methane concentrations up to several thousand parts per million.

  8. The Role of Temporal Evolution in Modeling Atmospheric Emissions from Tropical Fires

    NASA Technical Reports Server (NTRS)

    Marlier, Miriam E.; Voulgarakis, Apostolos; Shindell, Drew T.; Faluvegi, Gregory S.; Henry, Candise L.; Randerson, James T.

    2014-01-01

    Fire emissions associated with tropical land use change and maintenance influence atmospheric composition, air quality, and climate. In this study, we explore the effects of representing fire emissions at daily versus monthly resolution in a global composition-climate model. We find that simulations of aerosols are impacted more by the temporal resolution of fire emissions than trace gases such as carbon monoxide or ozone. Daily-resolved datasets concentrate emissions from fire events over shorter time periods and allow them to more realistically interact with model meteorology, reducing how often emissions are concurrently released with precipitation events and in turn increasing peak aerosol concentrations. The magnitude of this effect varies across tropical ecosystem types, ranging from smaller changes in modeling the low intensity, frequent burning typical of savanna ecosystems to larger differences when modeling the short-term, intense fires that characterize deforestation events. The utility of modeling fire emissions at a daily resolution also depends on the application, such as modeling exceedances of particulate matter concentrations over air quality guidelines or simulating regional atmospheric heating patterns.

  9. Fire effects on temperate forest soil C and N storage.

    PubMed

    Nave, Lucas E; Vance, Eric D; Swanston, Christopher W; Curtis, Peter S

    2011-06-01

    Temperate forest soils store globally significant amounts of carbon (C) and nitrogen (N). Understanding how soil pools of these two elements change in response to disturbance and management is critical to maintaining ecosystem services such as forest productivity, greenhouse gas mitigation, and water resource protection. Fire is one of the principal disturbances acting on forest soil C and N storage and is also the subject of enormous management efforts. In the present article, we use meta-analysis to quantify fire effects on temperate forest soil C and N storage. Across a combined total of 468 soil C and N response ratios from 57 publications (concentrations and pool sizes), fire had significant overall effects on soil C (-26%) and soil N (-22%). The impacts of fire on forest floors were significantly different from its effects on mineral soils. Fires reduced forest floor C and N storage (pool sizes only) by an average of 59% and 50%, respectively, but the concentrations of these two elements did not change. Prescribed fires caused smaller reductions in forest floor C and N storage (-46% and -35%) than wildfires (-67% and -69%), and the presence of hardwoods also mitigated fire impacts. Burned forest floors recovered their C and N pools in an average of 128 and 103 years, respectively. Among mineral soils, there were no significant changes in C or N storage, but C and N concentrations declined significantly (-11% and -12%, respectively). Mineral soil C and N concentrations were significantly affected by fire type, with no change following prescribed burns, but significant reductions in response to wildfires. Geographic variation in fire effects on mineral soil C and N storage underscores the need for region-specific fire management plans, and the role of fire type in mediating C and N shifts (especially in the forest floor) indicates that averting wildfires through prescribed burning is desirable from a soils perspective.

  10. Remote multi-function fire alarm system based on internet of things

    NASA Astrophysics Data System (ADS)

    Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu

    2018-05-01

    This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.

  11. Differential exposure and acute health impacts of inhaled solid-fuel emissions from rudimentary and advanced cookstoves in female CD-1 mice.

    PubMed

    Gibbs-Flournoy, Eugene A; Gilmour, M Ian; Higuchi, Mark; Jetter, James; George, Ingrid; Copeland, Lisa; Harrison, Randy; Moser, Virginia C; Dye, Janice A

    2018-02-01

    There is an urgent need to provide access to cleaner end user energy technologies for the nearly 40% of the world's population who currently depend on rudimentary cooking and heating systems. Advanced cookstoves (CS) are designed to cut emissions and solid-fuel consumption, thus reducing adverse human health and environmental impacts. We hypothesized that, compared to a traditional (Tier 0) three-stone (3-S) fire, acute inhalation of solid-fuel emissions from advanced natural-draft (ND; Tier 2) or forced-draft (FD; Tier 3) stoves would reduce exposure biomarkers and lessen pulmonary and innate immune system health effects in exposed mice. Across two simulated cooking cycles (duration ~ 3h), emitted particulate mass concentrations were reduced 80% and 62% by FD and ND stoves, respectively, compared to the 3-S fire; with corresponding decreases in particles visible within murine alveolar macrophages. Emitted carbon monoxide was reduced ~ 90% and ~ 60%, respectively. Only 3-S-fire-exposed mice had increased carboxyhemoglobin levels. Emitted volatile organic compounds were FD ≪ 3-S-fire ≤ ND stove; increased expression of genes involved in xenobiotic metabolism (COX-2, NQO1, CYP1a1) was detected only in ND- and 3-S-fire-exposed mice. Diminished macrophage phagocytosis was observed in the ND group. Lung glutathione was significantly depleted across all CS groups, however the FD group had the most severe, ongoing oxidative stress. These results are consistent with reports associating exposure to solid fuel stove emissions with modulation of the innate immune system and increased susceptibility to infection. Lower respiratory infections continue to be a leading cause of death in low-income economies. Notably, 3-S-fire-exposed mice were the only group to develop acute lung injury, possibly because they inhaled the highest concentrations of hazardous air toxicants (e.g., 1,3-butadiene, toluene, benzene, acrolein) in association with the greatest number of particles, and particles with the highest % organic carbon. However, no Tier 0-3 ranked CS group was without some untoward health effect indicating that access to still cleaner, ideally renewable, energy technologies for cooking and heating is warranted. Published by Elsevier Inc.

  12. A reconnaissance of the effects of a forest fire on water quality in Kings Canyon National Park, California

    USGS Publications Warehouse

    Hoffman, Ray J.; Ferreira, Rodger F.

    1976-01-01

    Following two forest fires in the Roaring River drainage basin, Kings Canyon National Park, Calif., water samples were collected from May to July 1974 to determine water-quality changes resulting from the fires. Field measurements included alkalinity , pH, specific conductance, temperature, and discharge. Samples were analyzed in the laboratory for major dissolved chemical constituents, selected plant nutrients, trace metals, suspended sediment, total organic carbon, and seston. Periphytic algae and benthic invertebrate samples were collected. A noticeable increase in the concentration of nitrogen was found in Roaring River immediately downstream from the Moraine Creek fire. The increase in the concentration of inorganic nitrogen compounds, however, was not great enough to pose a serious threat to the aquatic ecosystem. High total organic nitrogen concentrations may have been due, in part, to factors other than the effect of fire. The results of other water-quality measurements were typical of dilute Sierra Nevada streams and indicate that Roaring River was not adversely affected by the fires. (Woodard-USGS)

  13. Analysis of dioxin-like compounds in vegetation and soil samples burned in Catalan forest fires. Comparison with the corresponding unburned material.

    PubMed

    Martínez, M; Díaz-Ferrero, J; Martí, R; Broto-Puig, F; Comellas, L; Rodríguez-Larena, M C

    2000-12-01

    Only a few data are reported about the formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in forest fires. However, the inventories of sources undertaken by several European and American countries consider natural fires as a possible source of PCDD/F and, in some cases, as one of the most important. In our work we have analysed vegetation and soil samples burned in four forest fires which happened in Catalonia in the summer of 1998. The concentration of dioxin-like compounds (PCDD/F, non-ortho polychlorinated bi-phenyls (PCB) and mono-ortho PCB) has been compared to the concentration present in the corresponding unburned material collected in places near the fires but not affected. The results of this preliminary study show very low concentrations in all the samples, both burned and unburned. Although a change in the profile (proportional increase of tetrachlorinated congeners in PCDD/F) is observed in burned samples compared to unburned ones, the absolute values of concentration decrease in most samples. Therefore, natural fires seem not to be an important source of dioxin-like compounds. These results will be confirmed with air emissions measurements in future studies.

  14. Simulation of air quality impacts from prescribed fires on an urban area.

    PubMed

    Hu, Yongtao; Odman, M Talat; Chang, Michael E; Jackson, William; Lee, Sangil; Edgerton, Eric S; Baumann, Karsten; Russell, Armistead G

    2008-05-15

    On February 28, 2007, a severe smoke event caused by prescribed forest fires occurred in Atlanta, GA. Later smoke events in the southeastern metropolitan areas of the United States caused by the Georgia-Florida wild forest fires further magnified the significance of forest fire emissions and the benefits of being able to accurately predict such occurrences. By using preburning information, we utilize an operational forecasting system to simulate the potential air quality impacts from two large February 28th fires. Our "forecast" predicts that the scheduled prescribed fires would have resulted in over 1 million Atlanta residents being potentially exposed to fine particle matter (PM2.5) levels of 35 microg m(-3) or higher from 4 p.m. to midnight. The simulated peak 1 h PM2.5 concentration is about 121 microg m(-3). Our study suggests that the current air quality forecasting technology can be a useful tool for helping the management of fire activities to protect public health. With postburning information, our "hindcast" predictions improved significantly on timing and location and slightly on peak values. "Hindcast" simulations also indicated that additional isoprenoid emissions from pine species temporarily triggered by the fire could induce rapid ozone and secondary organic aerosol formation during late winter. Results from this study suggest that fire induced biogenic volatile organic compounds emissions missing from current fire emissions estimate should be included in the future.

  15. Mortality due to Vegetation Fire-Originated PM2.5 Exposure in Europe-Assessment for the Years 2005 and 2008.

    PubMed

    Kollanus, Virpi; Prank, Marje; Gens, Alexandra; Soares, Joana; Vira, Julius; Kukkonen, Jaakko; Sofiev, Mikhail; Salonen, Raimo O; Lanki, Timo

    2017-01-01

    Vegetation fires can release substantial quantities of fine particles (PM2.5), which are harmful to health. The fire smoke may be transported over long distances and can cause adverse health effects over wide areas. We aimed to assess annual mortality attributable to short-term exposures to vegetation fire-originated PM2.5 in different regions of Europe. PM2.5 emissions from vegetation fires in Europe in 2005 and 2008 were evaluated based on Moderate Resolution Imaging Spectroradiometer (MODIS) satellite data on fire radiative power. Atmospheric transport of the emissions was modeled using the System for Integrated modeLling of Atmospheric coMposition (SILAM) chemical transport model. Mortality impacts were estimated for 27 European countries based on a) modeled daily PM2.5 concentrations and b) population data, both presented in a 50 × 50 km2 spatial grid; c) an exposure-response function for short-term PM2.5 exposure and daily nonaccidental mortality; and d) country-level data for background mortality risk. In the 27 countries overall, an estimated 1,483 and 1,080 premature deaths were attributable to the vegetation fire-originated PM2.5 in 2005 and 2008, respectively. Estimated impacts were highest in southern and eastern Europe. However, all countries were affected by fire-originated PM2.5, and even the lower concentrations in western and northern Europe contributed substantially (~ 30%) to the overall estimate of attributable mortality. Our assessment suggests that air pollution caused by PM2.5 released from vegetation fires is a notable risk factor for public health in Europe. Moreover, the risk can be expected to increase in the future as climate change proceeds. This factor should be taken into consideration when evaluating the overall health and socioeconomic impacts of these fires. Citation: Kollanus V, Prank M, Gens A, Soares J, Vira J, Kukkonen J, Sofiev M, Salonen RO, Lanki T. 2017. Mortality due to vegetation fire-originated PM2.5 exposure in Europe-assessment for the years 2005 and 2008. Environ Health Perspect 125:30-37; http://dx.doi.org/10.1289/EHP194.

  16. National Fire Plan Research and Development 2001 Business Summary

    Treesearch

    USDA Forest Service

    2002-01-01

    Wildland fire remains a serious concern to the people of our Nation. This concern has been turned into action in the form of the National Fire Plan (NFP), an accelerated interagency effort, begun after the disastrous 2000 fire season, to step up, coordinate, and concentrate activity on reducing fire risks.

  17. Satellite data driven modeling system for predicting air quality and visibility during wildfire and prescribed burn events

    NASA Astrophysics Data System (ADS)

    Nair, U. S.; Keiser, K.; Wu, Y.; Maskey, M.; Berendes, D.; Glass, P.; Dhakal, A.; Christopher, S. A.

    2012-12-01

    The Alabama Forestry Commission (AFC) is responsible for wildfire control and also prescribed burn management in the state of Alabama. Visibility and air quality degradation resulting from smoke are two pieces of information that are crucial for this activity. Currently the tools available to AFC are the dispersion index available from the National Weather Service and also surface smoke concentrations. The former provides broad guidance for prescribed burning activities but does not provide specific information regarding smoke transport, areas affected and quantification of air quality and visibility degradation. While the NOAA operational air quality guidance includes surface smoke concentrations from existing fire events, it does not account for contributions from background aerosols, which are important for the southeastern region including Alabama. Also lacking is the quantification of visibility. The University of Alabama in Huntsville has developed a state-of-the-art integrated modeling system to address these concerns. This system based on the Community Air Quality Modeling System (CMAQ) that ingests satellite derived smoke emissions and also assimilates NASA MODIS derived aerosol optical thickness. In addition, this operational modeling system also simulates the impact of potential prescribed burn events based on location information derived from the AFC prescribed burn permit database. A lagrangian model is used to simulate smoke plumes for the prescribed burns requests. The combined air quality and visibility degradation resulting from these smoke plumes and background aerosols is computed and the information is made available through a web based decision support system utilizing open source GIS components. This system provides information regarding intersections between highways and other critical facilities such as old age homes, hospitals and schools. The system also includes satellite detected fire locations and other satellite derived datasets relevant for fire and smoke management.

  18. An investigation on polycyclic aromatic hydrocarbon emissions from pulverized coal combustion systems

    PubMed

    Pisupati; Wasco; Scaroni

    2000-05-29

    Results from a series of tests conducted to study the emission of polynuclear or polycyclic aromatic hydrocarbons (PAHs) from bench-scale and small industrial, water-tube boiler are discussed. A Middle Kittanning, and Upper Freeport seam coals were used in the study. Samples were extracted from the reactor outlet and from the inlet and outlet sides of the research boiler's (RB) baghouse using EPA promulgated methods.Only acenaphthene and fluoranthene were detected in down-fired combustor (DFC) samples. In addition to these two, naphthalene was detected in the RB samples. Emission factors ranged from 80 to 320 &mgr;g/kg of fuel fired. Although there were minor trends in the emissions' data, given the reproducibility limits for PAH compounds, no significant differences were found in the emissions with respect to the fuel type or form (pulverized coal (PC) vs. coal-water slurry fuel (CWSF), and raw vs. cleaned coal) and firing conditions (high and low excess air). The PAH emissions showed a decrease with increase in the firing rate.A bench-scale drop-tube reactor (DTR) was used to study the effects of temperature and residence time on PAH formation. The results revealed near constant PAH concentrations in the solid-phase samples, while the PAH concentrations in the vapor-phase samples increased as a function of temperature. At a temperature of around 1300 degrees C, the rate of PAH formation was exceeded by the rate of PAH oxidation, and PAH concentrations in the vapor phase began to decrease.

  19. Relationships between resting conductances, excitability, and t-system ionic homeostasis in skeletal muscle.

    PubMed

    Fraser, James A; Huang, Christopher L-H; Pedersen, Thomas H

    2011-07-01

    Activation of skeletal muscle fibers requires rapid sarcolemmal action potential (AP) conduction to ensure uniform excitation along the fiber length, as well as successful tubular excitation to initiate excitation-contraction coupling. In our companion paper in this issue, Pedersen et al. (2011. J. Gen. Physiol. doi:10.1085/jgp.201010510) quantify, for subthreshold stimuli, the influence upon both surface conduction velocity and tubular (t)-system excitation of the large changes in resting membrane conductance (G(M)) that occur during repetitive AP firing. The present work extends the analysis by developing a multi-compartment modification of the charge-difference model of Fraser and Huang to provide a quantitative description of the conduction velocity of actively propagated APs; the influence of voltage-gated ion channels within the t-system; the influence of t-system APs on ionic homeostasis within the t-system; the influence of t-system ion concentration changes on membrane potentials; and the influence of Phase I and Phase II G(M) changes on these relationships. Passive conduction properties of the novel model agreed with established linear circuit analysis and previous experimental results, while key simulations of AP firing were tested against focused experimental microelectrode measurements of membrane potential. This study thereby first quantified the effects of the t-system luminal resistance and voltage-gated Na(+) channel density on surface AP propagation and the resultant electrical response of the t-system. Second, it demonstrated the influence of G(M) changes during repetitive AP firing upon surface and t-system excitability. Third, it showed that significant K(+) accumulation occurs within the t-system during repetitive AP firing and produces a baseline depolarization of the surface membrane potential. Finally, it indicated that G(M) changes during repetitive AP firing significantly influence both t-system K(+) accumulation and its influence on the resting membrane potential. Thus, the present study emerges with a quantitative description of the changes in membrane potential, excitability, and t-system ionic homeostasis that occur during repetitive AP firing in skeletal muscle.

  20. Integrating pH, substrate, and plant regrowth effects on soil nitrogen cycling after fire

    NASA Astrophysics Data System (ADS)

    Hanan, E. J.; Schimel, J.; Tague, C.; D'Antonio, C. M.

    2014-12-01

    Mediterranean-type ecosystems are structured by fire. In California chaparral, fires uncouple N production and consumption by enhancing nitrification and reducing plant uptake. NO3- that accumulates after fire is vulnerable to leaching. However, the extent to which fires decouple N fluxes can vary spatially and with timing of fire, and the specific mechanisms controlling N metabolism in recovering chaparral are not well understood. We combined empirical analysis and modeling in two chaparral watersheds to better understand how these systems recover from fire, and to explore their sensitivity to changing climate and fire regimes. To evaluate how pH, charcoal, and NH4+ supply influence N cycling, we measured mineralization and nitrification rates in chaparral soils that burned 1, 4, 20 and 40 years prior to sampling. We then experimentally adjusted pH, charcoal, and NH4+ concentrations for all soils in a factorial design, and incubated them for 8 weeks. Each week, we measured respiration, exchangeable NH4+ and NO3- content, nitrification potential, microbial biomass, and pH. Then to project the effects of altered precipitation patterns and fire timing on nitrogen dynamics and recovery, we used the hydro-biogeochemical model RHESSys. Fires were imposed at the beginning and end of the growing season under various climates. NO3- production was highest in soils collected from the most recently burned sites. Also, NO3- concentrations increased over the course of incubation in soils from all sites, especially at high pH, and with NH4+ addition. Charcoal slightly augmented the effects of elevated pH and NH4+ on NO3- production iduring the early stages of incubation in 1 and 4-year old sites, while it slightly dampened their effects by week 8. However, in 20 and 40-year old sites, charcoal had no effect. Overall, nitrification was most powerfully constrained by NH4+ supply. However, increases in pH that occur after fire may enhance nitrification rates when substrate is available. Also, charcoal might enhance N cycling immediately after fire, perhaps by supplying C to microbes, but impacts are short-lived. Modeling results suggest that soil acidity and rapid plant recovery reduce leaching. However, during drought and temperature extremes nutrients pools recover more slowly when fires occur prior to the hot, dry summer.

  1. Fire Extinguishing Agents, Aqueous Film Forming Foam (AFFF) Liquid Concentration Partial Percentage

    DTIC Science & Technology

    1989-08-31

    AFFF concentrations. aqueous film forming foam , AFFF , firefighting ...Extinguishing Agents, Aqueous Film Forming Foam ( AFFF ) Liquid Concentration Partial Percentage F08637-88-C-0067 06022104F 2104 30 21043034 Applied Research...objective of this test series was to qualify 3/4 and 1 percent Aqueous Film Forming Foam ( AFFF ) concentrate for use in Air Force fire fighting

  2. The Impact of Fire on Mercury Cycling in Watershed Systems

    NASA Astrophysics Data System (ADS)

    Lopez, S.; Mendez, C.; Hogue, T.; Jay, J.

    2006-12-01

    Mercury methylation is a process by which the less-toxic inorganic mercury is transformed into methylmercury (MeHg). MeHg is a potent neurotoxin with a strong tendency to biomagnify within the food chain. Limited studies suggest that wildfires change the soil characteristics and contribute to Hg transport and possibly methylation in downstream ecosystems. We propose that post-fire Hg cycling can be related to various soil properties and burn characteristics. In order to better understand the effects of wildfires on Hg cycling, studies were undertaken within a burned watershed and a neighboring unburned site, Malibu Creek and Cold Creek, respectively. Soil sampling of the burned and control (unburned) regions were composed of 25 square foot grids with nine equidistant sampling points. Sediment samples for soil sieve analysis were collected at all grid points to determine the particle size distribution of the fine and coarse grain aggregates. Total Hg sediments were collected from the three middle points of the grid at two soil horizons to provide a vertical profile. Total Hg concentrations of the sediment samples were measured using the Direct Mercury Analyzer (DMA80). Initial analysis of the soil profiles reveals a decrease in Hg concentration at the soil surface (89 percent loss). Preliminary results indicate sites with the lowest concentration of Hg are characterized by a higher percentage of finer grain aggregates. Runoff from the first post-fire storm was extremely turbid and dark gray in color due to high levels of suspended solids (3980 mg/L). Total Hg concentrations in unfiltered and filtered samples (0.2 micron) were 196 and 4.7 ng/L, respectively, compared to the control which had unfiltered and filtered Hg levels of 6.1 and 2.3 ng/L, respectively, and 450 mg/L total suspended solids. The concentration of Hg on the particles was six times higher than the Hg content of suspended particles at the control site. Results also show much stronger partitioning (three-fold higher Kd's) to the solid phase in the fire- impacted site. On-going work includes: 1) analysis of Hg and ancillary geochemical parameters overlying water and porewater from samples collected in the streambed downstream of the fire, 2) analysis of Hg concentrations in various particle size fractions of soil; and 3) preliminary characterization of recovery through analysis of soil properties and Hg levels at the burned and control sites, one-year post-fire.

  3. The role of historical fire disturbance in the carbon dynamics of the pan-boreal region: A process-based analysis

    USGS Publications Warehouse

    Balshi, M. S.; McGuire, A.D.; Zhuang, Q.; Melillo, J.; Kicklighter, D.W.; Kasischke, E.; Wirth, C.; Flannigan, M.; Harden, J.; Clein, Joy S.; Burnside, T.J.; McAllister, J.; Kurz, W.A.; Apps, M.; Shvidenko, A.

    2007-01-01

    Wildfire is a common occurrence in ecosystems of northern high latitudes, and changes in the fire regime of this region have consequences for carbon feedbacks to the climate system. To improve our understanding of how wildfire influences carbon dynamics of this region, we used the process-based Terrestrial Ecosystem Model to simulate fire emissions and changes in carbon storage north of 45??N from the start of spatially explicit historically recorded fire records in the twentieth century through 2002, and evaluated the role of fire in the carbon dynamics of the region within the context of ecosystem responses to changes in atmospheric CO2 concentration and climate. Our analysis indicates that fire plays an important role in interannual and decadal scale variation of source/sink relationships of northern terrestrial ecosystems and also suggests that atmospheric CO2 may be important to consider in addition to changes in climate and fire disturbance. There are substantial uncertainties in the effects of fire on carbon storage in our simulations. These uncertainties are associated with sparse fire data for northern Eurasia, uncertainty in estimating carbon consumption, and difficulty in verifying assumptions about the representation of fires that occurred prior to the start of the historical fire record. To improve the ability to better predict how fire will influence carbon storage of this region in the future, new analyses of the retrospective role of fire in the carbon dynamics of northern high latitudes should address these uncertainties. Copyright 2007 by the American Geophysical Union.

  4. High severity fires, positive fire feedbacks and alternative stable states in Athrotaxis rainforest ecosystems in western Tasmania.

    NASA Astrophysics Data System (ADS)

    Holz, A.; Wood, S.; Fletcher, M. S.; Ward, C.; Hopf, F.; Veblen, T. T.; Bowman, D. M. J. S.

    2016-12-01

    Recurrent landscape fires present a powerful selective force on plant regeneration strategies that form a continuum between vegetative resprouters and obligate seeders. In the latter case, reduction of the interval between fires, combined with factors that affect plant traits and regeneration dynamics can drive plant population to local extinction. Here we use Athrotaxis selaginoides, a relict fire-sensitive Gondwanan tree species that occurs in western Tasmania, as model system to investigate the putative impacts of climate change and variability and human management of fire. We integrate landscape ecology (island-wide scale), with field survey and dendrochronology (stand-scale) and sedimentary records (watershed and landscape-scales) to garner a better understanding of the timing and impact of landscape fire on the vegetation dynamics of Athrotaxis at multiple scales. Across the species range sedimentary charcoal and pollen concentrations indicate that the recovery time since the last fire has consistently lengthened over the last 10,000 yrs. Stand-scale tree-age and fire-scar reconstructions suggest that populations of the Athrotxis have survive very infrequent landscape fires over the last 4-6 centuries, but that fire severity has increased following European colonization causing population collapse of Athrotaxis and an associate shift in stand structure and composition that favor resprouter species over obligate seeders. Overall our findings suggest that the resistance to fires and postfire recovery of populations of A. selaginoides have gradually declined throughout the Holocene and rapidly declined after Europeans altered fire regimes, a trend that matches the fate other Gondwanan conifers in temperate rainforests elsewhere in the southern Hemisphere.

  5. Fire Frequency and Vegetation Composition Influence Soil Nitrogen Cycling and Base Cations in an Oak Savanna Ecosystem

    NASA Astrophysics Data System (ADS)

    McLauchlan, K. K.; Nelson, D. M.; Perakis, S.; Marcotte, A. L.

    2017-12-01

    Fire frequency is crucial for maintaining savannas in the transition between forests and grasslands. In general, increasing fire frequency has two effects: it increases herbaceous plant cover more than woody plant cover, and it lowers soil organic matter stocks. These effects have been demonstrated at a long-term prescribed fire experiment in an oak savanna ecosystem at Cedar Creek Ecosystem Science Reserve, Minnesota, U.S.A. The fire experiment began in 1964 and oak savannas are burned at various frequencies ranging from every year to not at all. This has led to changes in vegetation ranging from almost 100% grassland to 100% oak forest. Additionally, nitrogen stocks almost doubled in the sites that were not burned, as it accumulated in the trees, leaf litter, and soil. We addressed additional soil changes taking place at this experiment by asking the question: How have fire and oak-grass balance affected soil nutrients, specifically nitrogen and base cations? Surface soils were collected from 12 plots on the oak savanna burn experiment. Soils were collected in increments to 100 cm depth, from under grass-dominated vegetation and from under tree-dominated vegetation. We non-destructively estimated soil base cations by measuring elemental concentrations of dried soil subsamples with a handheld x-ray fluorescence analyzer. We also measured carbon and nitrogen concentrations and isotopic composition of the soil samples. Soils in plots with high fire frequency had higher concentrations of calcium than soils in unburned plots (low fire frequency). Similar trends were seen for soil potassium, magnesium, and phosphorus concentrations. In contrast, soils in plots with high fire frequency had dramatically lowered nitrogen cycling rates and stocks across the oak savanna. The contrast between the responses of different nutrients to changing fire frequency has important implications for the consequences of fire and tree-grass composition on nutrient cycling dynamics.

  6. Carbonaceous aerosols from prescribed burning of a boreal forest ecosystem

    NASA Technical Reports Server (NTRS)

    Mazurek, Monica A.; Cofer, Wesley R., III; Levine, Joel S.

    1991-01-01

    During the boreal forest burn studied, the ambient concentrations for the particle carbon smoke aerosol are highest for the full-fire burn conditions and vary significantly throughout the burn. Collection strategies must accordingly define ranges in the smoke aerosol concentrations produced. While the highest elemental C concentrations are observed during full-fire conditions, the great majority of smoke aerosol particles are in the form of organic C particles irrespective of fire temperature. The formation of organic C light-scattering particles was a significant process in the burn studied.

  7. Effect of oxygen concentration on fire growth of various types of cable bending in horizontal and vertical orientations

    NASA Astrophysics Data System (ADS)

    Pangaribuan, Adrianus; Dhiputra, I. M. K.; Nugroho, Yulianto S.

    2017-03-01

    Electrical cable is a whole of the material including metal (cooper) conductor and its insulation, when an electrical cable is flowed by electric current, based on its own capacity, the temperature of cable conductor increases gradually. If the current flows above the cable carrying capacity, then an extreme temperature rises are expected. When temperature increase, the electric current flow inside cable conductor will decrease gradually related to the resistance and could occur repeatedly in a period. Since electrical faults on electrical cable system are often suspected as the cause of fires, thus this research aims to investigate measures of preventing the fire to start by means of controlling oxygen concentration in a cable compartment. The experimental work was conducted in laboratory by using electrical power cable of 1.5 mm2 size. Two transparent chambers were applied for studying the effect of vertical and horizontal orientations on the cable temperature rise, under various oxygen concentration of the gas streams. In the present work, the electrical was maintained at a constant level during a typical test run. Parametric studies reported in the paper include the use of a bare and insulated cables as well as the bending shape of the cable lines of a straight cable, coiled cable and randomly bent cable which were loaded with the same electric load and oxygen concentration in the gas supply.

  8. 40 CFR 61.43 - Emission testing-rocket firing or propellant disposal.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Emission testing-rocket firing or... Standard for Beryllium Rocket Motor Firing § 61.43 Emission testing—rocket firing or propellant disposal. (a) Ambient air concentrations shall be measured during and after firing of a rocket motor or...

  9. 40 CFR 61.43 - Emission testing-rocket firing or propellant disposal.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Emission testing-rocket firing or... Standard for Beryllium Rocket Motor Firing § 61.43 Emission testing—rocket firing or propellant disposal. (a) Ambient air concentrations shall be measured during and after firing of a rocket motor or...

  10. 40 CFR 61.43 - Emission testing-rocket firing or propellant disposal.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Emission testing-rocket firing or... Standard for Beryllium Rocket Motor Firing § 61.43 Emission testing—rocket firing or propellant disposal. (a) Ambient air concentrations shall be measured during and after firing of a rocket motor or...

  11. 40 CFR 61.43 - Emission testing-rocket firing or propellant disposal.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Emission testing-rocket firing or... Standard for Beryllium Rocket Motor Firing § 61.43 Emission testing—rocket firing or propellant disposal. (a) Ambient air concentrations shall be measured during and after firing of a rocket motor or...

  12. 40 CFR 61.43 - Emission testing-rocket firing or propellant disposal.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Emission testing-rocket firing or... Standard for Beryllium Rocket Motor Firing § 61.43 Emission testing—rocket firing or propellant disposal. (a) Ambient air concentrations shall be measured during and after firing of a rocket motor or...

  13. Temporal monitoring of perfluorooctane sulfonate accumulation in aquatic biota downstream of historical aqueous film forming foam use areas.

    PubMed

    Lanza, Heather A; Cochran, Rebecca S; Mudge, Joseph F; Olson, Adric D; Blackwell, Brett R; Maul, Jonathan D; Salice, Christopher J; Anderson, Todd A

    2017-08-01

    Perfluoroalkyl substances (PFAS) have recently received increased research attention, particularly concerning aquatic organisms and in regions of exposure to aqueous film forming foams (AFFFs). Air Force bases historically applied AFFFs in the interest of fire training exercises and have since expressed concern for PFAS contamination in biota from water bodies surrounding former fire training areas. Six PFAS were monitored, including perfluorooctane sulfonate (PFOS), in aquatic species from 8 bayou locations at Barksdale Air Force Base in Bossier City, Louisiana (USA) over the course of 1 yr. The focus was to evaluate temporal and spatial variability in PFAS concentrations from historic use of AFFF. The PFOS concentrations in fish peaked in early summer, and also increased significantly downstream of former fire training areas. Benthic organisms had lower PFOS concentrations than pelagic species, contrary to previous literature observations. Bioconcentration factors varied with time but were reduced compared with previously reported literature values. The highest concentration of PFOS in whole fish was 9349 ng/g dry weight, with 15% of samples exceeding what is believed to be the maximum whole fish concentration reported to date of 1500 ng/g wet weight. Further studies are ongoing, to measure PFAS in larger fish and tissue-specific partitioning data to compare with the current whole fish values. The high concentrations presently observed could have effects on higher trophic level organisms in this system or pose a potential risk to humans consuming contaminated fish. Environ Toxicol Chem 2017;36:2022-2029. © 2016 SETAC. © 2016 SETAC.

  14. Differences in human versus lightning fires between urban and rural areas of the boreal forest in interior Alaska

    USGS Publications Warehouse

    Calef, Monika; Varvak, Anna; McGuire, A. David

    2017-01-01

    In western North America, the carbon-rich boreal forest is experiencing warmer temperatures, drier conditions and larger and more frequent wildfires. However, the fire regime is also affected by direct human activities through suppression, ignition, and land use changes. Models are important predictive tools for understanding future conditions but they are based on regional generalizations of wildfire behavior and weather that do not adequately account for the complexity of human–fire interactions. To achieve a better understanding of the intensity of human influence on fires in this sparsely populated area and to quantify differences between human and lightning fires, we analyzed fires by both ignition types in regard to human proximity in urban (the Fairbanks subregion) and rural areas of interior Alaska using spatial (Geographic Information Systems) and quantitative analysis methods. We found substantial differences in drivers of wildfire: while increases in fire ignitions and area burned were caused by lightning in rural interior Alaska, in the Fairbanks subregion these increases were due to human fires, especially in the wildland urban interface. Lightning fires are starting earlier and fires are burning longer, which is much more pronounced in the Fairbanks subregion than in rural areas. Human fires differed from lightning fires in several ways: they started closer to settlements and highways, burned for a shorter duration, were concentrated in the Fairbanks subregion, and often occurred outside the brief seasonal window for lightning fires. This study provides important insights that improve our understanding of the direct human influence on recently observed changes in wildfire regime with implications for both fire modeling and fire management.

  15. Post-fire soil functionality and microbial community structure in a Mediterranean shrubland subjected to experimental drought.

    PubMed

    Hinojosa, M Belén; Parra, Antonio; Laudicina, Vito Armando; Moreno, José M

    2016-12-15

    Fire may cause significant alterations in soil properties. Post-fire soil dynamics can vary depending, among other factors, on rainfall patterns. However, little is known regarding variations in response to post-fire drought. This is relevant in arid and semiarid areas with poor soils, like much of the western Mediterranean. Furthermore, climate change projections in such areas anticipate reduced precipitation and longer annual drought periods, together with an increase in fire severity and frequency. This research evaluates the effects of experimental drought after fire on soil dynamics of a Cistus-Erica shrubland (Central Spain). A replicated (n=4) field experiment was conducted in which the total rainfall and its patterns were manipulated by means of a rain-out shelters and irrigation system. The treatments were: environmental control (natural rainfall), historical control (average rainfall, 2months drought), moderate drought (25% reduction of historical control, 5months drought) and severe drought (45% reduction, 7months drought). After one growing season under these rainfall treatments, the plots were burned. One set of unburned plots under natural rainfall served as an additional control. Soils were collected seasonally. Fire increased soil P and N availability. Post-fire drought treatments reduced available soil P but increased N concentration (mainly nitrate). Fire reduced available K irrespective of drought treatments. Fire reduced enzyme activities and carbon mineralization rate, a reduction that was higher in post-fire drought-treated soils. Fire decreased soil microbial biomass and the proportion of fungi, while that of actinomycetes increased. Post-fire drought decreased soil total microbial biomass and fungi, with bacteria becoming more abundant. Our results support that increasing drought after fire could compromise the resilience of Mediterranean ecosystems to fire. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Automated system for smoke dispersion prediction due to wild fires in Alaska

    NASA Astrophysics Data System (ADS)

    Kulchitsky, A.; Stuefer, M.; Higbie, L.; Newby, G.

    2007-12-01

    Community climate models have enabled development of specific environmental forecast systems. The University of Alaska (UAF) smoke group was created to adapt a smoke forecast system to the Alaska region. The US Forest Service (USFS) Missoula Fire Science Lab had developed a smoke forecast system based on the Weather Research and Forecasting (WRF) Model including chemistry (WRF/Chem). Following the successful experience of USFS, which runs their model operationally for the contiguous U.S., we develop a similar system for Alaska in collaboration with scientists from the USFS Missoula Fire Science Lab. Wildfires are a significant source of air pollution in Alaska because the climate and vegetation favor annual summer fires that burn huge areas. Extreme cases occurred in 2004, when an area larger than Maryland (more than 25000~km2) burned. Small smoke particles with a diameter less than 10~μm can penetrate deep into lungs causing health problems. Smoke also creates a severe restriction to air transport and has tremendous economical effect. The smoke dispersion and forecast system for Alaska was developed at the Geophysical Institute (GI) and the Arctic Region Supercomputing Center (ARSC), both at University of Alaska Fairbanks (UAF). They will help the public and plan activities a few days in advance to avoid dangerous smoke exposure. The availability of modern high performance supercomputers at ARSC allows us to create and run high-resolution, WRF-based smoke dispersion forecast for the entire State of Alaska. The core of the system is a Python program that manages the independent pieces. Our adapted Alaska system performs the following steps \\begin{itemize} Calculate the medium-resolution weather forecast using WRF/Met. Adapt the near real-time satellite-derived wildfire location and extent data that are received via direct broadcast from UAF's "Geographic Information Network of Alaska" (GINA) Calculate fuel moisture using WRF forecasts and National Fire Danger Rating System (NFDRS) fuel maps Calculate smoke emission components using a first order fire emission model Model the smoke plume rise yielding a vertically distribution that accounts for one-dimensional (vertical) concentrations of smoke constituents in the atmosphere above the fire Run WRF/Chem at high resolution for the forecast Use standard graphical tools to provide accessible smoke dispersion The system run twice each day at ARSC. The results will be freely available from a dedicated wildfire smoke web portal at ARSC.

  17. Fire-related medical science

    NASA Technical Reports Server (NTRS)

    Knight, Douglas R.

    1987-01-01

    Spacecraft fire safety may be improved by the use of a fire-retardant atmosphere in occupied spaces. Low concentrations of oxygen can protect humans from fire damage by reducing the rate and spread of combustion, but care must be taken to avoid the hypoxic effects of oxygen-lean atmospheres. Crews can live and work in 11 percent oxygen if barometric pressure were adjusted to maintain the partial pressure of oxygen above 16 kPa. Eleven percent oxygen should prevent most types of fires, since 15 percent oxygen retards the combustion of paper and 13 percent oxygen extinguishes pentane flames. Test results indicate that seated humans can perform mental tasks in atmospheres containing 11.5 percent oxygen. Although this strategy of fire safety is under consideration for submarines, it could be adapted to spacecraft once operational procedures define a maximum hyperbaric pressure and fire research defines the effects of reduced oxygen concentrations on combustion in low gravity environments.

  18. Nutrient dynamics across a dissolved organic carbon and burn gradient in central Siberia

    NASA Astrophysics Data System (ADS)

    Rodriguez-Cardona, B.; Coble, A. A.; Prokishkin, A. S.; Kolosov, R.; Spencer, R. G.; Wymore, A.; McDowell, W. H.

    2016-12-01

    In stream ecosystems, dissolved organic carbon (DOC) and nitrogen (N) processing are tightly linked. In temperate streams, greater DOC concentrations and higher DOC:NO3- ratios promote the greatest nitrate (NO3-) uptake. However, less is known about this relationship in other biomes including the arctic which is undergoing changes due to climate change contributing to thawing of permafrost and alterations in biogeochemical cycles in soils and streams. Headwater streams draining into the N. Tunguska River in the central Siberian plateau are affected by forest fires but little is known about the aquatic biogeochemical implications in both a thawing and burning landscape. There are clear patterns between carbon concentration and fire history where generally DOC concentration in streams decrease after fires and older burn sites have shown greater DOC concentrations and more bioavailable DOC that could promote greater heterotrophic uptake of NO3-. However, the relationship between nutrient dynamics, organic matter composition, and fire history in streams is not very clear. In order to assess the influence of organic matter composition and DOC concentration on nutrient uptake in arctic streams, we conducted a series of short-term nutrient addition experiments following the tracer addition for spiraling curve characterization (TASCC) method, consisting of NO3- and NH4++PO43- additions, across 4 streams that comprise a fire gradient that spans 3- >100 years since the last burn with DOC concentrations ranging between 12-23 mg C/L. We hypothesized that nutrient uptake would be greatest in older burn sites due to greater DOC concentrations and availability. We will specifically examine how nutrient uptake relates to DOC concentration and OM composition (analyzed via FTICR-MS) across the burn gradient. Across the four sites DOC concentration and DOC:NO3- ratios decreased from old burn sites to recently burned sites. Results presented here can elucidate on the potential impacts of permafrost thawing and forest fires on nutrient dynamics in arctic streams.

  19. Safety issues of high-concentrated hydrogen peroxide production used as rocket propellant

    NASA Astrophysics Data System (ADS)

    Romantsova, O. V.; Ulybin, V. B.

    2015-04-01

    The article dwells on the possibility of production of high-concentrated hydrogen peroxide with the Russian technology of isopropyl alcohol autoxidation. Analysis of fire/explosion hazards and reasons of insufficient quality is conducted for the technology. Modified technology is shown. Non-standard fire/explosion characteristics required for integrated fire/explosion hazards rating for modified hydrogen peroxide production based on the autoxidation of isopropyl alcohol are defined.

  20. Concentrating solar power (CSP) power cycle improvements through application of advanced materials

    NASA Astrophysics Data System (ADS)

    Siefert, John A.; Libby, Cara; Shingledecker, John

    2016-05-01

    Concentrating solar power (CSP) systems with thermal energy storage (TES) capability offer unique advantages to other renewable energy technologies in that solar radiation can be captured and stored for utilization when the sun is not shining. This makes the technology attractive as a dispatchable resource, and as such the Electric Power Research Institute (EPRI) has been engaged in research and development activities to understand and track the technology, identify key technical challenges, and enable improvements to meet future cost and performance targets to enable greater adoption of this carbon-free energy resource. EPRI is also involved with technically leading a consortium of manufacturers, government labs, and research organizations to enable the next generation of fossil fired power plants with advanced ultrasupercritical (A-USC) steam temperatures up to 760°C (1400°F). Materials are a key enabling technology for both of these seemingly opposed systems. This paper discusses how major strides in structural materials for A-USC fossil fired power plants may be translated into improved CSP systems which meet target requirements.

  1. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  2. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  3. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  4. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  5. Descriptive epidemiology of unintentional residential fire injuries in King County, WA, 1984 and 1985.

    PubMed Central

    Ballard, J E; Koepsell, T D; Rivara, F P; Van Belle, G

    1992-01-01

    Although most studies have concentrated on fatal residential fire injuries, which are a leading cause of fatal injuries in the United States, few investigators have examined in detail nonfatal injuries as a consequence of residential fires. This population-based study used the Washington State Fire Incident Reporting System to assess the incidence and descriptive epidemiology of fatal and nonfatal burns or respiratory tract damage resulting from unintentional residential fires. For the 2-year period 1984-85 in King County, WA, the mortality rate due to injury in a residential fire was 0.7 per 100,000 per year, and the incidence of nonfatal injuries was 5.6 per 100,000 per year. Of 17 fatalities, 59 percent of the deaths occurred at the scene of the fire. Of 128 persons with nonfatal injuries, 19 percent were hospitalized; although the 55 percent seen as outpatients and the 26 percent treated by the fire department or paramedics at the fire scene usually had minor injuries, they would not have been captured if only traditional data sources had been employed. Those injured averaged 2.8 days of restricted activity, but the range was from less than 1 day to 1 year. Injuries were more common in the households with a low socioeconomic status and among nonwhites, especially American Indians. Variation in incidence by age, sex, and source of ignition for deaths and nonfatal injuries suggests appropriate targets for future fire injury prevention programs. PMID:1641436

  6. Seasonal Forecasting of Fires across Southern Borneo, 1997-2010

    NASA Astrophysics Data System (ADS)

    Spessa, Allan; Field, Robert; Kaiser, Johannes; Langner, Andreas; Moore, Jonathan; Pappenberger, Florian; Siegert, Florian; Weber, Ulrich

    2014-05-01

    Wildfire is a fundamental Earth System process, affecting almost all biogeochemical cycles, and all vegetated biomes. Fires are naturally rare in humid tropical forests, and tropical trees are generally killed by even low-intensity fires. However, fire activity in the tropics has increased markedly over the past 15-20 years, especially in Indonesia, Amazonia, and more recently, central Africa also. Since fire is the prime tool for clearing land in the tropics, it not surprising that the increase in fire activity is strongly associated with increased levels of deforestation, which is driven mainly by world-wide demand for timber and agricultural commodities. The consequences of deforestation fires for biodiversity conservation and emissions of greenhouse gases and aerosols are enormous. For example, carbon emissions from tropical biomass burning are around 20% of annual average global fossil fuel emissions. The destructive fires in Indonesia during the exceptionally strong El Niño-induced drought in late 1997 and early 1998 rank as some of the largest peak emissions events in recorded history. Past studies estimate about 1Gt of carbon was released to the atmosphere from the Indonesian fires in 1997 (which were mostly concentrated in carbon-rich forested peatlands). This amount is equivalent to about 14% of the average global annual fossil fuel emissions released during the 1990s. While not as large as the 1997-98 events, significant emissions from biomass burning have also been recorded in other (less severe) El Niño years across Indonesia, in particular, 2002, 2004, 2006 and 2009-2010. Recent climate modelling studies indicate that the frequency of El Niño events may increase under future climate change, affecting many tropical countries, including Indonesia. An increased drought frequency plus a projected increase in population and land use pressures in Indonesia, imply there will be even more fires and emissions in future across the region. However, while several studies using historical data have established negative relationships between fires and antecedent rainfall, and/or positive relationships between fires and deforestation in regions affected by El Nino, comparatively little work has attempted to predict fires and emissions in such regions. Ensemble seasonal climate forecasts issued with several months lead-time have been applied to support risk assessment systems in many fields, notably agricultural production and natural disaster management of flooding, heat waves, drought and fire. The USA, for example, has a long-standing seasonal fire danger prediction system. Fire danger monitoring systems have been operating in Indonesia for over a decade, but, as of yet, no fire danger prediction systems exist. Given the effort required to mobilise suppression and prevention measures in Indonesia, one could argue that high fire danger periods must be anticipated months in advance for mitigation and response measures to be effective. To address this need, the goal of our work was to examine the utility of seasonal rainfall forecasts in predicting severe fires in Indonesia more than one month in advance, using southern Borneo (comprising the bulk of Kalimantan) as a case study. Here we present the results of comparing seasonal forecasts of monthly rainfall from ECMWF's System 4 against i) observed rainfall (GPCP), and ii) burnt area and deforestation (MODIS, AVHRR and Landsat) across southern Borneo for the period 1997-2010. Our results demonstrate the utility of using ECMWF's seasonal climate forecasts for predicting fire activity in the region. Potential applications include improved fire mitigation and responsiveness, and improved risk assessments of biodiversity and carbon losses through fire. These are important considerations for forest protection programmes (e.g. REDD+), forest carbon markets and forest (re)insurance enterprises.

  7. Real-time, in situ, continuous monitoring of CO in a pulverized-coal-fired power plant with a 2.3 μm laser absorption sensor

    NASA Astrophysics Data System (ADS)

    Chao, Xing; Jeffries, Jay B.; Hanson, Ronald K.

    2013-03-01

    A real-time, in situ CO sensor using 2.3 μm DFB diode laser absorption, with calibration-free wavelength-modulation-spectroscopy, was demonstrated for continuous monitoring in the boiler exhaust of a pulverized-coal-fired power plant up to temperatures of 700 K. The sensor was similar to a design demonstrated earlier in laboratory conditions, now refined to accommodate the harsh conditions of utility boilers. Measurements were performed across a 3 m path in the particulate-laden economizer exhaust of the coal-fired boiler. A 0.6 ppm detection limit with 1 s averaging was estimated from the results of a continuous 7-h-long measurement with varied excess air levels. The measured CO concentration exhibited expected inverse trends with the excess O2 concentration, which was varied between 1 and 3 %. Measured CO concentrations ranged between 6 and 200 ppm; evaluation of the data suggested a dynamic range from 6 to 10,000 ppm based on a minimum signal-to-noise ratio of ten and maximum absorbance of one. This field demonstration of a 2.3 μm laser absorption sensor for CO showed great potential for real-time combustion exhaust monitoring and control of practical combustion systems.

  8. BlueSky Cloud - rapid infrastructure capacity using Amazon's Cloud for wildfire emergency response

    NASA Astrophysics Data System (ADS)

    Haderman, M.; Larkin, N. K.; Beach, M.; Cavallaro, A. M.; Stilley, J. C.; DeWinter, J. L.; Craig, K. J.; Raffuse, S. M.

    2013-12-01

    During peak fire season in the United States, many large wildfires often burn simultaneously across the country. Smoke from these fires can produce air quality emergencies. It is vital that incident commanders, air quality agencies, and public health officials have smoke impact information at their fingertips for evaluating where fires and smoke are and where the smoke will go next. To address the need for this kind of information, the U.S. Forest Service AirFire Team created the BlueSky Framework, a modeling system that predicts concentrations of particle pollution from wildfires. During emergency response, decision makers use BlueSky predictions to make public outreach and evacuation decisions. The models used in BlueSky predictions are computationally intensive, and the peak fire season requires significantly more computer resources than off-peak times. Purchasing enough hardware to run the number of BlueSky Framework runs that are needed during fire season is expensive and leaves idle servers running the majority of the year. The AirFire Team and STI developed BlueSky Cloud to take advantage of Amazon's virtual servers hosted in the cloud. With BlueSky Cloud, as demand increases and decreases, servers can be easily spun up and spun down at a minimal cost. Moving standard BlueSky Framework runs into the Amazon Cloud made it possible for the AirFire Team to rapidly increase the number of BlueSky Framework instances that could be run simultaneously without the costs associated with purchasing and managing servers. In this presentation, we provide an overview of the features of BlueSky Cloud, describe how the system uses Amazon Cloud, and discuss the costs and benefits of moving from privately hosted servers to a cloud-based infrastructure.

  9. Simulation of the FRP Product

    NASA Astrophysics Data System (ADS)

    Paugam, Ronan; Wooster, Martin; Johnston, Joshua; Gastellu-Etchegorry, Jean-Philippe

    2014-05-01

    Among the different alternative of remote sensing technologies for estimating global fire carbon emission, the thermally-based measures of fire radiative power (FRP; and its temporal integration, fire radiative energy or FRE) has the potential to capture the spatial and temporal variability of fire occurrence. It was shown that a strong linear relationship exists between the total amount of thermal radiant energy emitted by a fire over its lifetime (the FRE) and the amount of fuel burned. Since all vegetation is 50(±5)% carbon, it is therefore in theory a potentially simple matter to measure the FRE and estimate the carbon release. In a fire inventory like the Global Fire Assimilation System (GFAS), the total carbon emission is derived from a gridded FRE product forced by the MODIS observation, using Ct = β x FRE x Ef, where β is a conversion factor initially estimated from small scale experiment as β=0.368 and later derived for different bio dome by comparison with the Global Fire Emission Database (GFED). The sensitivities of the above equation to (i) different types of fire activity (ie, flaming, smoldering, torching), (ii) sensor view angles or (iii) soot/smoke absorption have not yet been well studied. The investigation of these types of sensitivity, and of the information content of thermal IR observations of actively burning fires in general, is one of the primary subjects of this study. Our approach is based on a combination of observational work and simulations conducted via the linkage of different fire models and the 3D radiative transfer (RT) model DART operating in the thermal domain. The radiation properties of a fire as seen from above its plume (e.g. space/air borne sensor) depend on the temperature distribution, the gas concentration (mainly CO2, H2O), and the amount, shape, distribution and optical properties of the soot particles in the flame (where they are emitting) and in the cooling plume (where they are mainly absorbing). While gas and soot radiative properties can be estimated from the literature, their concentration and temperature are calculated from output of fire models. Due to the large range of length scale involved in fire dynamics, a twofold approach is use to model the fire scene with (i) first the multi-phases model WFDS which can handle fire size ranging from a 1m2 to 1ha with a particular focus on flame-plume interaction, (ii) and then the meso scale model WRF-fire which can handle larger fires and the interaction plume-atmosphere (e.g. pyroconvection). In the former case, as the Radiative Transfer is WFDS is based on a Gray Body assumption (WFDS only focuses on fire dynamics) the main challenge is to derive the radiative properties of the different component of the fire scene (soot and gas) for the different bands (optical and IR) solved in DART to re-process a multispectral RT. In the later case, because WRF-fire is running at a resolution of tens of meters, pyrolysis and combustion processes cannot be resolved and to predict the fire front dynamics, the use of an empirical model based on the Rothermel equation and the level set method is required. In this later case, it is therefore necessary to use empirical relationship to determine: (i) the 3D structure of the flame defined by: flame length, flame height and fire front depth derived from Rate of Spread and residence time, (ii) the gas and soot concentration profile within the flame, and (iii) the convective flux generated by the flame. The development of these empirical relationships presents one of the main challenges of this work. Thought this work is still undergoing, first results show the potential impact of view angle on the evaluation of FRP.

  10. Wildfires and geochemical change in a subalpine forest over the past six millennia

    NASA Astrophysics Data System (ADS)

    Leys, Bérangère; Higuera, Philip E.; McLauchlan, Kendra K.; Dunnette, Paul V.

    2016-12-01

    The frequency of large wildfires in western North America has been increasing in recent decades, yet the geochemical impacts of these events are poorly understood. The multidecadal timescales of both disturbance-regime variability and ecosystem responses make it challenging to study the effects of fire on terrestrial nutrient cycling. Nonetheless, disturbance-mediated changes in nutrient concentrations could ultimately limit forest productivity over centennial to millennial time scales. Here, we use a novel approach that combines quantitative elemental analysis of lake sediments using x-ray fluorescence to assess the geochemical impacts of high-severity fires in a 6200 year long sedimentary record from a small subalpine lake in Rocky Mountain National Park, Colorado, USA. Immediately after 17 high-severity fires, the sedimentary concentrations of five elements increased (Ti, Ca, K, Al, and P), but returned to pre-fire levels within three decades. Multivariate analyses indicate that erosion of weathered mineral material from the catchment is a primary mechanism though which high-severity fires impact element cycling. A longer-term trend in sediment geochemistry was also identified over millennial time scales. This decrease in the concentrations of six elements (Al, Si, K, Ti, Mn, and Fe) over the past 6200 years may have been due to a decreased rate of high-severity fires, long-term ecosystem development, or changes in precipitation regime. Our results indicate that high-severity fire events can determine elemental concentrations in subalpine forests. The degree of variability in geochemical response across time scales suggests that shifting rates of high-severity burning can cause significant changes in key rock-derived nutrients. To our knowledge, these results are the first to reveal repeated loss of rock-derived nutrients from the terrestrial ecosystem due to high-severity fires. Understanding the future of fire-prone coniferous forests requires further documentation and quantification of this important mechanism linking fire regimes and biogeochemical cycles.

  11. Enhanced sorption of PAHs in natural-fire-impacted sediments from Oriole Lake, California.

    PubMed

    Sullivan, Julia; Bollinger, Kevyn; Caprio, Anthony; Cantwell, Mark; Appleby, Peter; King, John; Ligouis, Bertrand; Lohmann, Rainer

    2011-04-01

    Surface sediment cores from Oriole Lake (CA) were analyzed for organic carbon (OC), black carbon (BC), and their δ(13)C isotope ratios. Sediments displayed high OC (20-25%) and increasing BC concentrations from ∼0.40% (in 1800 C.E.) to ∼0.60% dry weight (in 2000 C.E.). Petrographic analysis confirmed the presence of fire-derived carbonaceous particles/BC at ∼2% of total OC. Natural fires were the most likely cause of both elevated polycyclic aromatic hydrocarbon (PAH) concentrations and enhanced sorption in Oriole Lake sediments prior to 1850, consistent with their tree-ring-based fire history. In contrast to other PAHs, retene and perylene displayed decreasing concentrations during periods with natural fires, questioning their use as fire tracers. The occurrence of natural fires, however, did not result in elevated concentrations of black carbon or chars in the sediments. Only the 1912-2007 sediment layer contained anthropogenic particles, such as soot BC. In this layer, combining OC absorption with adsorption to soot BC (using a Freundlich coefficient n = 0.7) explained the observed sorption well. In the older layers, n needed to be 0.3 and 0.5 to explain the enhanced sorption to the sediments, indicating the importance of natural chars/inertinites in sorbing PAHs. For phenanthrene, values of n differed significantly between sorption to natural chars (0.1-0.4) and sorption to anthropogenic black carbon (>0.5), suggesting it could serve as an in situ probe of sorbents.

  12. Numerical and Experimental Study on the Effect of Over Fire Air on NOx Distribution in Furnace

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Deng, Yong-qiang; Xia, Yong-jun; Wu, Ying

    2018-05-01

    In this paper, a numerical investigation and experimental study was used to research the effect of a power plant 600MW supercritical four walls tangentially fired boiler furnace over fire air opening size on the inside furnace NOx concentration distribution and the results coincide. There are four cases in all. The influence and formation of NOx that was produced by pulverized coal furnace during combustion processes were analyzed. The research was proved that the over fire air has great effect on the concentration distribution of NOx in the furnance.

  13. Multi-trophic resilience of boreal lake ecosystems to forest fires

    USGS Publications Warehouse

    Lewis, Tyler L.; Lindberg, Mark S.; Schmutz, Joel A.; Bertram, M.R.

    2014-01-01

    Fires are the major natural disturbance in the boreal forest, and their frequency and intensity will likely increase as the climate warms. Terrestrial nutrients released by fires may be transported to boreal lakes, stimulating increased primary productivity, which may radiate through multiple trophic levels. Using a before-after-control-impact (BACI) design, with pre- and postfire data from burned and unburned areas, we examined effects of a natural fire across several trophic levels of boreal lakes, from nutrient and chlorophyll levels, to macroinvertebrates, to waterbirds. Concentrations of total nitrogen and phosphorus were not affected by the fire. Chlorophyll levels were also unaffected, likely reflecting the stable nutrient concentrations. For aquatic invertebrates, we found that densities of three functional feeding groups did not respond to the fire (filterers, gatherers, scrapers), while two groups increased (shredders, predators). Amphipods accounted for 98% of shredder numbers, and we hypothesize that fire-mediated habitat changes may have favored their generalist feeding and habitat ecology. This increase in amphipods may, in turn, have driven increased predator densities, as amphipods were the most numerous invertebrate in our lakes and are commonly taken as prey. Finally, abundance of waterbird young, which feed primarily on aquatic invertebrates, was not affected by the fire. Overall, ecosystems of our study lakes were largely resilient to forest fires, likely due to their high initial nutrient concentrations and small catchment sizes. Moreover, this resilience spanned multiple trophic levels, a significant result for ecologically similar boreal regions, especially given the high potential for increased fires with future climate change.

  14. Multi-trophic resilience of boreal lake ecosystems to forest fires.

    PubMed

    Lewis, Tyler L; Lindberg, Mark S; Schmutz, Joel A; Bertram, Mark R

    2014-05-01

    Fires are the major natural disturbance in the boreal forest, and their frequency and intensity will likely increase as the climate warms. Terrestrial nutrients released by fires may be transported to boreal lakes, stimulating increased primary productivity, which may radiate through multiple trophic levels. Using a before-after-control-impact (BACI) design, with pre- and postfire data from burned and unburned areas, we examined effects of a natural fire across several trophic levels of boreal lakes, from nutrient and chlorophyll levels, to macroinvertebrates, to waterbirds. Concentrations of total nitrogen and phosphorus were not affected by the fire. Chlorophyll a levels were also unaffected, likely reflecting the stable nutrient concentrations. For aquatic invertebrates, we found that densities of three functional feeding groups did not respond to the fire (filterers, gatherers, scrapers), while two groups increased (shredders, predators). Amphipods accounted for 98% of shredder numbers, and we hypothesize that fire-mediated habitat changes may have favored their generalist feeding and habitat ecology. This increase in amphipods may, in turn, have driven increased predator densities, as amphipods were the most numerous invertebrate in our lakes and are commonly taken as prey. Finally, abundance of waterbird young, which feed primarily on aquatic invertebrates, was not affected by the fire. Overall, ecosystems of our study lakes were largely resilient to forest fires, likely due to their high initial nutrient concentrations and small catchment sizes. Moreover, this resilience spanned multiple trophic levels, a significant result for ecologically similar boreal regions, especially given the high potential for increased fires with future climate change.

  15. A fine-particle sodium tracer for long-range transport of the Kuwaiti oil-fire smoke

    NASA Astrophysics Data System (ADS)

    Lowenthal, Douglas H.; Borys, Randolph D.; Rogers, C. Fred; Chow, Judith C.; Stevens, Robert K.; Pinto, Joe P.; Ondov, John M.

    1993-04-01

    Evidence for long-range transport of the Kuwaiti oil-fire smoke during the months following the Persian Gulf War has been more or less indirect. For example, high concentrations of aerosol particles containing soot and oil-combustion tracers such as vanadium observed at great distances from the Middle East may have come from sources other than the oil fires. However, more-recent data on the aerosol chemistry of Kuwaiti oil-fire plumes provides a direct link between those fires and aerosols collected at the Mauna Loa Observatory (MLO) during the late spring and summer of 1991.By itself, temporal covariation of fine-particle concentrations of elemental carbon, sulfur, and the noncrustal V / Zn ratio in MLO aerosols suggested a link to large-scale oil-combustion sources, but not necessarily to Kuwait. However, high concentrations of fine-particle (0.1-1.0 µm diameter) NaCl were observed in the “white” oil-fire plumes over Kuwait during the summer of 1991. Further analysis of the Mauna Loa data indicates strong temporal correspondence between the noncrustal V / Zn and noncrustal Na / Zn ratios and strong consistency between the noncrustal Na to noncrustal V ratios found at Mauna Loa and in the Kuwaiti oil-fire plume. In the absence of other demonstrable sources of fine-particle Na, these relationships provide a direct link between the Kuwaiti oil fires and aerosol composition observed at MLO.

  16. Acute toxicity of fire-retardant and foam-suppressant chemicals to early life stages of chinook salmon (Oncorhynchus tshawytscha)

    USGS Publications Warehouse

    Buhl, Kevin J.; Hamilton, Steven J.

    1998-01-01

    Laboratorys studies were conducted to determine the acute toxicity of three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F), and two fire-suppressant foams (Phos-Chek WD-881 and Ansul Silv-Ex) to early life stages of chinook salmon, Oncorhynchus tshawytscha, in hard and soft water. Regardless of water type, swim-up fry and juveniles (60 and 90 d posthatch) exhibited similar sensitivities to each chemical and these life stages were more sensitive than eyed eggs. Foam suppressants were more toxic to each life stage than the fire retardants in both water types. The descending rank order of toxicity for these chemicals tested with swim-up fry and juveniles (range of 96-h median lethal concentrations [LC50s]) was Phos-Chek WD-881 (7–13 mg/L) > Ansul Silv-Ex (11–22 mg/L) > Phos-Chek D75-F (218–305 mg/L) > Fire-Trol GTS-R (218–412 mg/L) > Fire-Trol LCG-R (685–1,195 mg/L). Water type had a minor effect on the toxicity of these chemicals. Comparison of acute toxicity values with recommended application concentrations indicates that accidental inputs of these chemicals into stream environments would require substantial dilution (237- to 1,429-fold) to reach concentrations equivalent to their 96-h LC50s.

  17. Effect of a long-term fire retardant (Fire Trol 934) on the germination of nine Mediterranean-type shrub species.

    PubMed

    Cruz, Alberto; Serrano, Marián; Navarro, Esther; Luna, Belén; Moreno, José M

    2005-12-01

    Fire Trol 934 is a long-term fire retardant commonly used in fire prevention and extinction. Our objective was to determine the effect of this chemical on seed germination of nine plant species from Mediterranean-type shrublands, where these chemicals are potentially used. Seeds were exposed to five different Fire Trol concentrations, (0 (control) to 10%, on a log scale) and monitored in a germination chamber for nine weeks. Seeds from four Cistus species were subjected to an additional heat treatment that simulated thermal scarification caused by fire. Retardant exposure caused a significant decrease in total germination in all species, and exposure to the highest Fire Trol concentration (10%) resulted in complete inhibition of germination. However, the sensitivity to Fire Trol varied across species and this differential species sensitivity may potentially lead to different impacts in the soil seed banks depending on whether sites are burned or unburned. Exposure to Fire Trol 934 may affect recruitment of shrubland species particularly during dry autumns, due to limited leaching of these chemicals from the soil surface. Consequently, its use should be avoided in sites where particularly sensitive plant species are present. Copyright (c) 2005 Wiley Periodicals, Inc.

  18. Aspen response to prescribed fire and wild ungulate herbivory

    Treesearch

    Steve Kilpatrick; Diane Abendroth

    2001-01-01

    Land management agencies in northwest Wyoming have implemented an active prescribed fire program to address historically altered fire regimes, regenerate aspen, and improve overall watershed functions. Treated clones are susceptible to extensive browsing from elk concentrated on supplemental feedgrounds and from wintering moose. Previous attempts at fire-induced aspen...

  19. Impact of postfire management on soil respiration and C concentration in a managed hemiboreal forest

    NASA Astrophysics Data System (ADS)

    Köster, Kajar; Seglinš, Katrin; Parro, Kristi; Metslaid, Marek

    2017-04-01

    Fire is the main natural disturbance in boreal forests and it is expected that its frequency will increase as a result of climate change. Fire is the primary process which organizes the physical and biological attributes of the boreal biome and influences energy flows and biogeochemical cycles, particularly the carbon (C) cycle. The objective of this study was to assess the impact of forest fire and time since forest fire on soil respiration and soil C concentrations in scenarios where the area was managed or was not managed after fire disturbance. This study was carried out in two permanent research areas in northwestern Estonia (hemiboreal forest zone) that were damaged by fire: Vihterpalu (59o13' N 23o49' E) and Nõva (59o10' N 23o45' E). Fire occurred in Vihterpalu in year 1992 (550 ha burned), when the forest was 52 years old, and in Nõva in year 2008 (800 ha burned), when the forest was 70 years old. Before the fire disturbance both sites were covered with planted or sown Scots pine (Pinus sylvestris L.) forests originally regenerated after heavy fires in 1940 (Nõva) and 1951 (Vihterpalu). In all areas we are dealing with stand replacing fires where all (or almost all) of the stand was destroyed by fire. In both study areas three different types of sample areas were set up: 1) control areas (CO), that are unburned and no management activities carried out; 2) burned and cleared (BC) with salvage logging, areas in which all dead and live trees were harvested from the plot after fire; 3) burned and uncleared areas (BU), areas without management in which both dead and live trees were left on the plots after fire disturbance. On every area three measuring transects (40 m long) were established where soil respiration (g CO2 m-2h-1) was measured on five collars, and five soil samples (0.5 m long and 0.05 m in diameter) were taken to estimate soil C (kg m-2) content. In our study, highest soil respiration values were recorded in control (CO) areas, which are not affected by forest fires. In the fire areas (BC and BU) the average soil respiration values were more than two times lower than in the areas which were not affected by forest fires. Different post-fire management activities (removing or leaving damaged trees) did not affect the soil respiration values. Soil temperature had a significant impact on the CO2 flows. The recorded average soil temperature was lowest in CO and highest in BU areas, respectively. In spring and autumn soil temperatures in disturbed areas, as well as in cleared areas, were rising faster than in CO areas. In our study, 1992 fire areas had thicker litter and organic layer compared to 2008 fire areas. Most of the litter and organic matter was found in CO areas, followed by BU and BC areas. The highest C concentrations were found in CO areas. In the fire areas C concentration was also affected by the post-disturbance management, as in BC areas soil C concentration was lower compared to BU areas.

  20. Using the Large Fire Simulator System to map wildland fire potential for the conterminous United States

    Treesearch

    LaWen Hollingsworth; James Menakis

    2010-01-01

    This project mapped wildland fire potential (WFP) for the conterminous United States by using the large fire simulation system developed for Fire Program Analysis (FPA) System. The large fire simulation system, referred to here as LFSim, consists of modules for weather generation, fire occurrence, fire suppression, and fire growth modeling. Weather was generated with...

  1. A Numerical Study of Atmospheric Perturbations Induced by Heat From a Wildland Fire: Sensitivity to Vertical Canopy Structure and Heat Source Strength

    NASA Astrophysics Data System (ADS)

    Kiefer, Michael T.; Zhong, Shiyuan; Heilman, Warren E.; Charney, Joseph J.; Bian, Xindi

    2018-03-01

    An improved understanding of atmospheric perturbations within and above a forest during a wildland fire has relevance to many aspects of wildland fires including fire spread, smoke transport and dispersion, and tree mortality. In this study, the ARPS-CANOPY model, a version of the Advanced Regional Prediction System (ARPS) model with a canopy parameterization, is utilized in a series of idealized numerical experiments to investigate the influence of vertical canopy structure on the atmospheric response to a stationary sensible heat flux at the ground ("fire heat flux"), broadly consistent in magnitude with the sensible heat flux from a low-intensity surface fire. Five vertical canopy structures are combined with five fire heat flux magnitudes to yield a matrix of 25 simulations. Analyses of the fire-heat-flux-perturbed u component of the wind, vertical velocity, kinetic energy, and temperature show that the spatial pattern and magnitude of the perturbations are sensitive to vertical canopy structure. Both vertical velocity and kinetic energy exhibit an increasing trend with increasing fire heat flux that is stronger for cases with some amount of overstory vegetation than cases with exclusively understory vegetation. A weaker trend in cases with exclusively understory vegetation indicates a damping of the atmospheric response to the sensible heat from a surface fire when vegetation is most concentrated near the surface. More generally, the results presented in this study suggest that canopy morphology should be considered when applying the results of a fire-atmosphere interaction study conducted in one type of forest to other forests with different canopy structures.

  2. Electronic firing systems and methods for firing a device

    DOEpatents

    Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  3. Large-scale, thick, self-assembled, nacre-mimetic brick-walls as fire barrier coatings on textiles

    NASA Astrophysics Data System (ADS)

    Das, Paramita; Thomas, Helga; Moeller, Martin; Walther, Andreas

    2017-01-01

    Highly loaded polymer/clay nanocomposites with layered structures are emerging as robust fire retardant surface coatings. However, time-intensive sequential deposition processes, e.g. layer-by-layer strategies, hinders obtaining large coating thicknesses and complicates an implementation into existing technologies. Here, we demonstrate a single-step, water-borne approach to prepare thick, self-assembling, hybrid fire barrier coatings of sodium carboxymethyl cellulose (CMC)/montmorillonite (MTM) with well-defined, bioinspired brick-wall nanostructure, and showcase their application on textile. The coating thickness on the textile is tailored using different concentrations of CMC/MTM (1-5 wt%) in the coating bath. While lower concentrations impart conformal coatings of fibers, thicker continuous coatings are obtained on the textile surface from highest concentration. Comprehensive fire barrier and fire retardancy tests elucidate the increasing fire barrier and retardancy properties with increasing coating thickness. The materials are free of halogen and heavy metal atoms, and are sourced from sustainable and partly even renewable building blocks. We further introduce an amphiphobic surface modification on the coating to impart oil and water repellency, as well as self-cleaning features. Hence, our study presents a generic, environmentally friendly, scalable, and one-pot coating approach that can be introduced into existing technologies to prepare bioinspired, thick, fire barrier nanocomposite coatings on diverse surfaces.

  4. Forest fire increases mercury accumulation by fishes via food web restructuring and increased mercury inputs.

    PubMed

    Kelly, Erin N; Schindler, David W; St Louis, Vincent L; Donald, David B; Vladicka, Katherine E

    2006-12-19

    Recent findings indicate that fishes from lakes in partially burned catchments contain greater mercury (Hg) concentrations than fishes from reference catchments. Increased methyl Hg (MeHg) concentrations in fishes can result in serious health problems for consumers. Here we show that a forest fire caused a 5-fold increase in whole-body Hg accumulation by rainbow trout (Oncorhynchus mykiss) and smaller Hg increases in muscle of several fish species in a mountain lake. The enhanced Hg accumulation was caused primarily by increased nutrient concentrations in the lake, which enhanced productivity and restructured the food web through increased piscivory and consumption of Mysis. This restructuring resulted in increases to the trophic positions and Hg concentrations of fishes. Forest fire also caused a large short-term release of total Hg (THg) and MeHg to streams and the lake. This release initiated a small pulse of MeHg in invertebrates that contributed to enhanced Hg accumulation by fishes. Climate change and prescribed burning to compensate for past fire suppression are predicted to increase future forest fire occurrence in North America, and increased Hg accumulation by fishes may be an unexpected consequence.

  5. Forest fire increases mercury accumulation by fishes via food web restructuring and increased mercury inputs

    PubMed Central

    Kelly, Erin N.; Schindler, David W.; St. Louis, Vincent L.; Donald, David B.; Vladicka, Katherine E.

    2006-01-01

    Recent findings indicate that fishes from lakes in partially burned catchments contain greater mercury (Hg) concentrations than fishes from reference catchments. Increased methyl Hg (MeHg) concentrations in fishes can result in serious health problems for consumers. Here we show that a forest fire caused a 5-fold increase in whole-body Hg accumulation by rainbow trout (Oncorhynchus mykiss) and smaller Hg increases in muscle of several fish species in a mountain lake. The enhanced Hg accumulation was caused primarily by increased nutrient concentrations in the lake, which enhanced productivity and restructured the food web through increased piscivory and consumption of Mysis. This restructuring resulted in increases to the trophic positions and Hg concentrations of fishes. Forest fire also caused a large short-term release of total Hg (THg) and MeHg to streams and the lake. This release initiated a small pulse of MeHg in invertebrates that contributed to enhanced Hg accumulation by fishes. Climate change and prescribed burning to compensate for past fire suppression are predicted to increase future forest fire occurrence in North America, and increased Hg accumulation by fishes may be an unexpected consequence. PMID:17158215

  6. A low-cost particulate matter (PM2.5) monitor for wildland fire smoke

    NASA Astrophysics Data System (ADS)

    Kelleher, Scott; Quinn, Casey; Miller-Lionberg, Daniel; Volckens, John

    2018-02-01

    Wildfires and prescribed fires produce emissions that degrade visibility and are harmful to human health. Smoke emissions and exposure monitoring is critical for public and environmental health protection; however, ground-level measurements of smoke from wildfires and prescribed fires has proven difficult, as existing (validated) monitoring technologies are expensive, cumbersome, and generally require line power. Few ground-based measurements are made during fire events, which limits our ability to assess the environmental and human health impacts of wildland fire smoke. The objective of this work was to develop and validate an Outdoor Aerosol Sampler (OAS) - a filter-based air sampler that has been miniaturized, solar powered, and weatherproofed. This sampler was designed to overcome several of the technical challenges of wildland fire monitoring by being relatively inexpensive and solar powered. The sampler design objectives were achieved by leveraging low-cost electronic components, open-source programming platforms, and in-house fabrication methods. A direct-reading PM2.5 sensor was selected and integrated with the OAS to provide time-resolved concentration data. Cellular communications established via short message service (SMS) technology were utilized in transmitting online sensor readings and controlling the sampling device remotely. A Monte Carlo simulation aided in the selection of battery and solar power necessary to independently power the OAS, while keeping cost and size to a minimum. Thirteen OAS were deployed to monitor smoke concentrations downwind from a large prescribed fire. Aerosol mass concentrations were interpolated across the monitoring network to depict smoke concentration gradients in the vicinity of the fire. Strong concentration gradients were observed (spatially and temporally) and likely present due to a combination of changing fire location and intensity, topographical features (e.g., mountain ridges), and diurnal weather patterns. Gravimetric filter measurements made by the OAS (when corrected for filter collection efficiency) showed relatively good agreement with measurements from an EPA federal equivalent monitor. However, the real-time optical sensor (Sharp GP2Y1023AU0F, Sharp Electronic Co.) within the OAS suffered from temperature dependence, drift, and imprecision.

  7. 14 CFR 29.1195 - Fire extinguishing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing systems. 29.1195 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Powerplant Fire Protection § 29.1195 Fire... inches must have a fire extinguishing system for the designated fire zones. The fire extinguishing system...

  8. Local and regional smoke impacts from prescribed fires

    NASA Astrophysics Data System (ADS)

    Price, Owen F.; Horsey, Bronwyn; Jiang, Ningbo

    2016-10-01

    Smoke from wildfires poses a significant threat to affected communities. Prescribed burning is conducted to reduce the extent and potential damage of wildfires, but produces its own smoke threat. Planners of prescribed fires model the likely dispersion of smoke to help manage the impacts on local communities. Significant uncertainty remains about the actual smoke impact from prescribed fires, especially near the fire, and the accuracy of smoke dispersal models. To address this uncertainty, a detailed study of smoke dispersal was conducted for one small (52 ha) and one large (700 ha) prescribed fire near Appin in New South Wales, Australia, through the use of stationary and handheld pollution monitors, visual observations and rain radar data, and by comparing observations to predictions from an atmospheric dispersion model. The 52 ha fire produced a smoke plume about 800 m high and 9 km long. Particle concentrations (PM2.5) reached very high peak values (> 400 µg m-3) and high 24 h average values (> 100 µg m-3) at several locations next to or within ˜ 500 m downwind from the fire, but low levels elsewhere. The 700 ha fire produced a much larger plume, peaking at ˜ 2000 m altitude and affecting downwind areas up to 14 km away. Both peak and 24 h average PM2.5 values near the fire were lower than for the 52 ha fire, but this may be because the monitoring locations were further away from the fire. Some lofted smoke spread north against the ground-level wind direction. Smoke from this fire collapsed to the ground during the night at different times in different locations. Although it is hard to attribute particle concentrations definitively to smoke, it seems that the collapsed plume affected a huge area including the towns of Wollongong, Bargo, Oakdale, Camden and Campbelltown (˜ 1200 km2). PM2.5 concentrations up to 169 µg m-3 were recorded on the morning following the fire. The atmospheric dispersion model accurately predicted the general behaviour of both plumes in the early phases of the fires, but was poor at predicting fine-scale variation in particulate concentrations (e.g. places 500 m from the fire). The correlation between predicted and observed varied between 0 and 0.87 depending on location. The model also completely failed to predict the night-time collapse of the plume from the 700 ha fire. This study provides a preliminary insight into the potential for large impacts from prescribed fire smoke to NSW communities and the need for increased accuracy in smoke dispersion modelling. More research is needed to better understand when and why such impacts might occur and provide better predictions of pollution risk.

  9. Motor unit activation patterns during concentric wrist flexion in humans with different muscle fibre composition.

    PubMed

    Søgaard, K; Christensen, H; Fallentin, N; Mizuno, M; Quistorff, B; Sjøgaard, G

    1998-10-01

    Muscle activity was recorded from the flexor carpi radialis muscle during static and dynamic-concentric wrist flexion in six subjects, who had exhibited large differences in histochemically identified muscle fibre composition. Motor unit recruitment patterns were identified by sampling 310 motor units and counting firing rates in pulses per second (pps). During concentric wrist flexion at 30% of maximal exercise intensity the mean firing rate was 27 (SD 13) pps. This was around twice the value of 12 (SD 5) pps recorded during sustained static contraction at 30% of maximal voluntary contraction, despite a larger absolute force level during the static contraction. A similar pattern of higher firing rates during dynamic exercise was seen when concentric wrist flexion at 60% of maximal exercise intensity [30 (SD 14) pps] was compared with sustained static contraction at 60% of maximal voluntary contraction [19 (SD 8) pps]. The increase in dynamic exercise intensity was accomplished by recruitment of additional motor units rather than by increasing the firing rate as during static contractions. No difference in mean firing rates was found among subjects with different muscle fibre composition, who had previously exhibited marked differences in metabolic response during corresponding dynamic contractions. It was concluded that during submaximal dynamic contractions motor unit firing rate cannot be deduced from observations during static contractions and that muscle fibre composition may play a minor role.

  10. What does it take to start an oropharyngeal fire? Oxygen requirements to start fires in the operating room.

    PubMed

    Roy, Soham; Smith, Lee P

    2011-02-01

    Airway fires are a well-described and potentially devastating complication of oropharyngeal surgery. However, the actual factors required to ignite the fire have never been well-delineated in the medical literature. In this study, we used a mechanical model to assess the oxygen parameters necessary to cause an oropharyngeal fire. An electrosurgical unit (Bovie) was grounded to a whole raw chicken and a 6.0 endotracheal tube (ETT) was inserted into the cranial end of the degutted central cavity. Oxygen (O(2)) was then titrated through the ETT tube at varying concentrations, with flow rates varying from 10 to 15L/min. Electrocautery (at a setting of 15W) was performed on tissue in the central cavity of the chicken near the ETT. All trials were repeated twice to ensure accuracy. Positive test results were quantified by the time required to obtain ignition of any part of the mechanical setup and time required to produce a sustained flame. A test was considered negative if no ignition could be obtained after four minutes of direct electrocautery. At an O(2) concentration of 100% and a flow rate of 15L/min, ignition with a sustained flame was obtained between 15 and 30s after initiation of electrocautery. At 100% O(2) at 10L/min, ignition was obtained at 70s with immediate sustained flame. At an O(2) concentration of 60%, ignition occurred at 25s and sustained fire after 60s. At an O(2) concentration of 50% ignition with a sustained flame occurred between 128 and 184s. At an O(2) concentration of 45%, neither ignition nor sustained flames could be obtained in any trial. Operating room fires remain a genuine danger when performing oropharyngeal surgery where electrocautery is performed in an oxygen-enriched environment. In our study, higher O(2) flow rates with higher FiO(2) correlated with quicker ignition in the chicken cavity. A fire was easily obtained when using 100% O(2); as the O(2) concentration decreases, longer exposure to electrocautery is required for ignition. Below 50% O(2) we were unable to obtain ignition. Our study is the first to examine the relative risk of ignition and sustained fire in a mechanical model of oropharyngeal surgery. Decreasing the fraction of inspired O(2) (FiO(2)) to less than 50% may substantially decrease the risk of airway fire during oropharyngeal surgery. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  11. PM2.5 and Carbon Emissions from Prescribed Fire in a Longleaf Pine Ecosystem

    NASA Astrophysics Data System (ADS)

    Strenfel, S. J.; Clements, C. B.; Hiers, J. K.; Kiefer, C. M.

    2008-12-01

    Prescribed fires are a frequently utilized land-management tool in the Southeastern US. In order to better characterize emissions and impacts from prescribed fire in longleaf pine ecosystems, in situ data were obtained within the burn perimeter using a 10-m instrumented flux tower. Turbulence and temperature data at 10-m were sampled at 10 Hz using a sonic anemometer and fine-wire thermocouples respectively. Measurements of PM2.5, CO and CO2 emissions were sampled at 10-m within the burn perimeter and PM2.5 and Black Carbon PM2.5 were sampled 0.5 km downwind of the fire front using a 2-m instrumented tripod. Preliminary results indicate PM2.5 and carbon emissions significantly increased during the fire-front passage, and downwind PM concentrations were amplified beyond pre-fire ambient concentrations. In addition, the considerable amount a heat release and flux data gathered from these prescribed fires suggests that near surface atmospheric conditions were directly impacted by increased turbulence generation.

  12. Ultrafine and respirable particle exposure during vehicle fire suppression

    PubMed Central

    Fent, Kenneth W.

    2015-01-01

    Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters’ potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator’s shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 107 particles per cm3, 170 mg m−3 respirable particle mass, 4700 μm2 cm−3 active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 104 particles per cm3, 0.36 mg m−3 respirable particle mass, 92 μm2 cm−3 active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 105 particles per cm3, 2.7 mg m−3 respirable particle mass, 320 μm2 cm−3 active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews’ potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures. PMID:26308547

  13. Ultrafine and respirable particle exposure during vehicle fire suppression.

    PubMed

    Evans, Douglas E; Fent, Kenneth W

    2015-10-01

    Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters' potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator's shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 10(7) particles per cm(3), 170 mg m(-3) respirable particle mass, 4700 μm(2) cm(-3) active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 10(4) particles per cm(3), 0.36 mg m(-3) respirable particle mass, 92 μm(2) cm(-3) active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 10(5) particles per cm(3), 2.7 mg m(-3) respirable particle mass, 320 μm(2) cm(-3) active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews' potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures.

  14. Estimating Potential Increased Bladder Cancer Risk Due to Increased Bromide Concentrations in Sources of Disinfected Drinking Waters

    EPA Science Inventory

    Public water systems are increasingly facing higher bromide levels in their source waters from anthropogenic contamination through coal-fired power plants, conventional oil and gas extraction, and hydraulic fracturing. Climate change is likely to exacerbate this in coming years. ...

  15. Estimating Potential Increased Bladder Cancer Risk Due to Increased Bromide Concentrations in Sources of Disinfected Drinking Waters - slides

    EPA Science Inventory

    Public water systems are increasingly facing higher bromide levels in their source waters from anthropogenic contamination through coal-fired powerplants, conventional oil and gas extraction, and hydraulic fracturing. Climate change is likely to exacerbate this in coming years. W...

  16. PERFORMANCE RESULTS OF JET-REMPI AS A REAL-TIME PCDD/F EMISSION MONITOR

    EPA Science Inventory

    The Jet REMPI monitor was recently tested on a hazardous-waste firing boiler for its ability to determine real time concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI consists of a laser system coupled with a time of flight mass spectrometer ...

  17. Trans-Pacific and Regional Atmospheric Transport of Polycyclic Aromatic Hydrocarbons and Pesticides in Biomass Burning Emissions to Western North America

    PubMed Central

    Genualdi, Susan A.; Killin, Robert K.; Woods, Jim; Wilson, Glenn; Schmedding, David; Massey Simonich, Staci L.

    2014-01-01

    The trans-Pacific and regional North American atmospheric transport of polycyclic aromatic hydrocarbons (PAHs) and pesticides in biomass burning emissions was measured in air masses from April to September 2003 at two remote sites in western North America. Mary’s Peak Observatory (MPO) is located in Oregon’s Coast Range and Cheeka Peak Observatory (CPO) is located on the tip of the Olympic Peninsula in Washington State. During this time period, both remote sites were influenced by PAH and pesticide emissions from forest fires in Siberia and regional fires in Oregon and Washington State. Concurrent samples were taken at both sites on June 2 and August 4, 2003. On these dates, CPO had elevated gas phase PAH, alpha-hexachlorocyclohexane and retene concentrations (p<0.05) and MPO had elevated retene, particulate phase PAH and levoglucosan concentrations due to trans-Pacific transport of emissions from fires in Siberia. In addition, during the April to September 2003 sampling period, CPO and MPO were influenced by emissions from regional fires that resulted in elevated levoglucosan, dacthal, endosulfan and gas phase PAH concentrations. Burned and unburned forest soil samples collected from the regional forest fire area showed that 34 to 100% of the pesticide mass was lost from soil due to burning. These data suggest that the transPacific and regional atmospheric transport of biomass burning emissions results in elevated PAH and pesticide concentrations in western North America. The elevated pesticide concentrations are likely due to re-emission of historically deposited pesticides from the soil and vegetation during the fire event. PMID:19320158

  18. Pre- and post-fire pollutant loads in an urban fringe watershed in Southern California.

    PubMed

    Burke, M P; Hogue, T S; Kinoshita, A M; Barco, J; Wessel, C; Stein, E D

    2013-12-01

    Post-fire runoff has the potential to be a large source of contaminants to downstream areas. However, the magnitude of this effect in urban fringe watersheds adjacent to large sources of airborne contaminants is not well documented. The current study investigates the impacts of wildfire on stormwater contaminant loading from the upper Arroyo Seco watershed, burned in 2009. This watershed is adjacent to the Greater Los Angeles, CA, USA area and has not burned in over 60 years. Consequently, it acts as a sink for regional urban pollutants and presents an opportunity to study the impacts of wildfire. Pre- and post-fire storm samples were collected and analyzed for basic cations, trace metals, and total suspended solids. The loss of vegetation and changes in soil properties from the fire greatly increased the magnitude of storm runoff, resulting in sediment-laden floods carrying high concentrations of particulate-bound constituents. Post-fire concentrations and loads were up to three orders of magnitude greater than pre-fire values for many trace metals, including lead and cadmium. A shift was also observed in the timing of chemical delivery, where maximum suspended sediment, trace metal, and cation concentrations coincided with, rather than preceded, peak discharge in the post-fire runoff, amplifying the fire's impacts on mass loading. The results emphasize the importance of sediment delivery as a primary mechanism for post-fire contaminant transport and suggest that traditional management practices that focus on treating only the early portion of storm runoff may be less effective following wildfire. We also advocate that watersheds impacted by regional urban pollutants have the potential to pose significant risk for downstream communities and ecosystems after fire.

  19. Occupational Exposure to Polycyclic Aromatic Hydrocarbon of Wildland Firefighters at Prescribed and Wildland Fires.

    PubMed

    Navarro, Kathleen M; Cisneros, Ricardo; Noth, Elizabeth M; Balmes, John R; Hammond, S Katharine

    2017-06-06

    Wildland firefighters suppressing wildland fires or conducting prescribed fires work long shifts during which they are exposed to high levels of wood smoke with no respiratory protection. Polycyclic aromatic hydrocarbons (PAHs) are hazardous air pollutants formed during incomplete combustion. Exposure to PAHs was measured for 21 wildland firefighters suppressing two wildland fires and 4 wildland firefighters conducting prescribed burns in California. Personal air samples were actively collected using XAD4-coated quartz fiber filters and XAD2 sorbent tubes. Samples were analyzed for 17 individual PAHs through extraction with dichloromethane and gas chromatograph-mass spectrometer analysis. Naphthalene, retene, and phenanthrene were consistently the highest measured PAHs. PAH concentrations were higher at wildland fires compared to prescribed fires and were highest for firefighters during job tasks that involve the most direct contact with smoke near an actively burning wildland fire. Although concentrations did not exceed current occupational exposure limits, wildland firefighters are exposed to PAHs not only on the fire line at wildland fires, but also while working prescribed burns and while off-duty. Characterization of occupational exposures from wildland firefighting is important to understand better any potential long-term health effects.

  20. North African savanna fires and atmospheric carbon dioxide

    NASA Technical Reports Server (NTRS)

    Iacobellis, Sam F.; Frouin, Robert; Razafimpanilo, Herisoa; Somerville, Richard C. J.; Piper, Stephen C.

    1994-01-01

    The effect of north African savanna fires on atmospheric CO2 is investigated using a tracer transport model. The model uses winds from operational numerical weather prediction analyses and provides CO2 concentrations as a function of space and time. After a spin-up period of several years, biomass-burning sources are added, and model experiments are run for an additional year, utilizing various estimates of CO2 sources. The various model experiments show that biomass burning in the north African savannas significantly affects CO2 concentrations in South America. The effect is more pronounced during the period from January through March, when biomass burning in South America is almost nonexistent. During this period, atmospheric CO2 concentrations in parts of South America typically may increase by 0.5 to 0.75 ppm at 970 mbar, the average pressure of the lowest model layer. These figures are above the probable uncertainty level, as model runs with biomass-burning sources estimated from independent studies using distinct data sets and techniques indicate. From May through September, when severe biomass burning occurs in South America, the effect of north African savanna fires over South America has become generally small at 970 mbar, but north of the equator it may be of the same magnitude or larger than the effect of South American fires. The CO2 concentration increase in the extreme northern and southern portions of South America, however, is mostly due to southern African fires, whose effect may be 2-3 times larger than the effect of South American fires at 970 mbar. Even in the central part of the continent, where local biomass-burning emissions are maximum, southern African fires contribute to at least 15% of the CO2 concentration increase at 970 mbar. At higher levels in the atmosphere, less CO2 emitted by north African savanna fires reaches South America, and at 100 mbar no significant amount of CO2 is transported across the Atlantic Ocean. The vertical structure of the CO2 concentration increase due to biomass burning differs substantially, depending on whether sources are local or remote. A prominent maximum of CO2 concentration increase in the lower layers characterizes the effect of local sources, whereas a more homogeneous profile of CO2 concentration increase characterizes the effect of remote sources. The results demonstrate the strong remote effects of African biomoass burning which, owing to the general circulation of the atmosphere, are felt as far away as South America.

  1. Quantifying fire emissions and associated aerosols species using assimilation of satellite carbon monoxide retrievals.

    NASA Astrophysics Data System (ADS)

    Barre, J.; Edwards, D. P.; Worden, H. M.

    2016-12-01

    Wildfires tend to be more intense and hence costly and are predicted to increase in frequency under a warming climate. For example, the recent August 2015 Washington State fires were the largest in the state's history. Also in September and October 2015 very intense fires over Indonesia produced some of the highest concentration of carbon monoxide (CO) ever seen from space. Such larges fires impact not only the local environment but also affects air quality far downwind through the long-range transport of pollutants. Global to continental scale coverage showing the evolution of CO resulting from fire emission is available from satellite observations. Carbon monoxide is the only atmospheric trace gas for which satellite multispectral retrievals have demonstrated reliable independent profile information close to the surface and also higher in the free troposphere. The unique CO profile product from Terra/MOPITT clearly distinguishes near-surface CO from the free troposphere CO. Also previous studies have suggested strong correlations between primary emissions of fire organic and black carbon aerosols and CO. We will present results from the Ensemble Adjustement Kalman Filter (DART) system that has been developed to assimilate MOPITT CO in the global scale chemistry-climate model CAM-Chem. The ensemble technique allows inference on various fire model state variables such as CO emissions and also aerosol species resulting from fires such as organic and black carbon. The benefit of MOPITT CO assimilation on the Washington and Indonesian fire cases studies will be diagnosed regarding the CO fire emissions, black and organic carbon inference using the ensemble information.

  2. Exposure to radionuclides in smoke from vegetation fires.

    PubMed

    Carvalho, Fernando P; Oliveira, João M; Malta, Margarida

    2014-02-15

    Naturally occurring radionuclides of uranium, thorium, radium, lead and polonium were determined in bushes and trees and in the smoke from summer forest fires. Activity concentrations of radionuclides in smoke particles were much enriched when compared to original vegetation. Polonium-210 ((210)Po) in smoke was measured in concentrations much higher than all other radionuclides, reaching 7,255 ± 285 Bq kg(-1), mostly associated with the smaller size smoke particles (<1.0 μm). Depending on smoke particle concentration, (210)Po in surface air near forest fires displayed volume concentrations up to 70 m Bq m(-3), while in smoke-free air (210)Po concentration was about 30 μ Bq m(-3). The estimated absorbed radiation dose to an adult member of the public or a firefighter exposed for 24h to inhalation of smoke near forest fires could exceed 5 μSv per day, i.e, more than 2000 times above the radiation dose from background radioactivity in surface air, and also higher than the radiation dose from (210)Po inhalation in a chronic cigarette smoker. It is concluded that prolonged exposure to smoke allows for enhanced inhalation of radionuclides associated with smoke particles. Due to high radiotoxicity of alpha emitting radionuclides, and in particular of (210)Po, the protection of respiratory tract of fire fighters is strongly recommended. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. DoD Is Not Properly Monitoring the Initiation of Maintenance for Facilities at Kandahar Airfield, Afghanistan (REDACTED)

    DTIC Science & Technology

    2013-09-30

    fire sprinkler system during the initial construction of the RSOI facilities. The construction contract to build the RSOI...International Building Code. Compliant manual and automatic fire alarm and notification systems , portable fire extinguishers, fire sprinkler systems ...automatic fire sprinkler system that was not operational, a fire department connection that was obstructed, and a fire detection system

  4. Changes in Fire-Derived Soil Black Carbon Storage in a Sub-humid Woodland

    NASA Astrophysics Data System (ADS)

    White, J. D.; Yao, J.; Murray, D. B.; Hockaday, W. C.

    2014-12-01

    Fire-derived black carbon (BC) in soil, including charcoal, represents a potentially important fraction of terrestrial carbon cycling due to its presumed long persistence in soil. Interpretation of site BC retention is important for assessing feedbacks to ecosystem processes including nutrient and water cycling. However, interaction between vegetation disturbance, BC formation, and off site transport may exist that complicate interpretation of BC addition to soils from wildfire or prescribed burns directly. To investigate the relationship between disturbance and site retention on soil BC, we determined BC concentrations for a woodland in central Texas, USA, from study plots in hilly terrain with a fire scar dendrochronology spanning 100 years. BC values were determined from 13C nuclear magnetic resonance (NMR) spectroscopy. Estimated values showed mean BC concentration of 2.73 ± 3.06 g BC kg-1 (0.91 ± 0.51 kg BC m-2) for sites with fire occurrence within the last 40 years compared with BC values of1.21 ± 1.70 g BC kg-1 soil (0.18 ± 0.14 kg BC m-2) for sites with fire 40 - 100 years ago. Sites with no tree ring evidence of fire during the last 100 years had the lowest mean soil BC concentration of 0.05 ± 0.11 g BC kg-1 (0.02 ± 0.03 kg BC m-2). Molecular proxies of stability (lignin/N) and decomposition (Alkyl C/O-Alky C) showed no differences across the sites, indicating that low potential for BC mineralization. Modeled soil erosion and time since fire from fire scar data showed that soil BC concentrations were inversely correlated. A modified the ecosystem process model, Biome-BGC, was also used simulate the effects of fire disturbance with different severities and seasonality on C cycling related to the BC production, effect on soil water availability, and off-site transport. Results showed that BC impacts on ecosystem processes, including net ecosystem exchange and leaf area development, were predominantly related to fire frequency. Site BC loss rates were affected by initial slope-affected erosion, fire severity, vegetation type, and rate of vegetation recovery. The simulation results showed that fire types, such as high severity, was generally associated with low site BC retention related to low vertical transfer of BC into soils, buoyancy of BC particles, and surface runoff from unvegetated soils.

  5. Guidance and Control Aspects of Tactical Air-Launched Missiles

    DTIC Science & Technology

    1980-10-01

    information; - Continuously stimulating advances in the aerospace sciences relevant to strengthening the common defence pusture; -- Improving the co...Symposium on Precision Delivery Systems was held at Eglin Air Force Base , Florida. USA. Many important advances in guidance sensor technology, control system...paper concentrates primarily or the US Army Missile Command’s technology base for development of the precision pointing and tracking or fire control

  6. The role of DOM in nitrogen processing in streams across arctic regions affected by fire

    NASA Astrophysics Data System (ADS)

    Rodriguez-Cardona, B.; Schade, J. D.; Holmes, R. M.; Natali, S.; Mann, P. J.; Wymore, A.; Coble, A. A.; Prokishkin, A. S.; Zito, P.; Podgorski, D. C.; Spencer, R. G.; McDowell, W. H.

    2017-12-01

    In stream ecosystems, inputs of dissolved organic carbon (DOC) have a strong influence on nitrogen (N) processing. Previous studies have demonstrated that increases in DOC concentrations can promote greater N removal in many stream ecosystems. Most of what we know about C and N coupling comes from studies of temperate streams; less is known about this relationship in the Arctic. Streams in Arctic ecosystems are facing rapid changes in climate and disturbance regimes, in particular increasing fire frequencies that are likely to alter biogeochemical cycles. Although fires can lead to increases in NO3 concentrations in streams, the effects of fire on DOC (concentration and composition) have been difficult to generalize. We studied the relationships between DOC and N in two locations; the Central Siberian Plateau, Russia and the Yukon-Kuskokwim (YK) River Delta, Alaska. Streams in both regions show increases in NO3 concentrations after fire, while DOC concentrations decrease in Siberia but increase in streams within the YK-Delta. These patterns in DOC and NO3 create a gradient in DOC and nutrient concentrations, allowing us to study this coupling in a wider Pan-Arctic scope. In order to assess the role of DOC in Arctic N processing, we conducted NO3 and NH4 additions to stream microcosms at the Alaskan site as well as whole-stream additions in Siberia. We hypothesized that nutrient uptake would be high in older burn sites of Siberia and recently burned sites in the YK-Delta, due to greater DOC concentrations and availability. Our results suggest that nitrogen dynamics in the Alaskan sites is strongly responsive to C availability, but is less so in Siberian sites. The potential impacts of permafrost thawing and fires on DOM and nutrient dynamics thus appear to not be consistent across the Arctic suggesting that different regions of the Arctic have unique biogeochemical controls.

  7. Contamination of local wildlife following a fire at a polychlorinated biphenyls warehouse in St Basile le Grand, Quebec, Canada.

    PubMed

    Phaneuf, D; DesGranges, J L; Plante, N; Rodrigue, J

    1995-02-01

    This study on wildlife contamination, one to ten months after the polychlorinated biphenyls (PCB) fire in St Basile le Grand, Quebec, shows that the fire increased PCB and polychlorinated dibenzofuran (PCDF) levels in animals. From the data, it was not possible to detect a significant increase in polychlorinated dibenzodioxin (PCDD) levels after the fire. Given the relatively small sample size, the differences in concentrations could not be estimated precisely. However, it can be asserted with a 95% confidence level that mean concentrations of total PCBs were roughly 2 to 6 times higher in the area contaminated by the plume of smoke, concentrations of homologues with 3 chlorine atoms were 1 to 4 times higher, and levels of homologues with 5 to 9 chlorine atoms were 3 to 13 times higher. The relative deviations between concentrations in areas under the plume and those outside it were similar for all animals sampled. With regard to total PCDFs, mean concentrations were significantly higher under the smoke plume than outside it for all species. This observation is linked to homologues with 4, 5 and 7 chlorine atoms for which significant differences were detected between the two areas. The fire had no effect on the pattern of PCB congeners found in the tissue of animals in the region. Congeners Nos. 153, 180, 138 and 118 represent approximately 50% of total PCBs. Although PCB and PCDF concentrations were higher in the tissue of local wildlife species exposed to the fire, they were nonetheless comparable to those found in other urban and agricultural areas in Canada. These concentrations, in 2,3,7,8-TCDD toxic equivalents, were much lower than those observed in the wake of three other major incidents involving PCDDs (Elgin, Florida; Times Beach, Missouri; and Seveso, Italy).(ABSTRACT TRUNCATED AT 250 WORDS)

  8. A Crashworthiness Analysis with Emphasis on the Fire Hazard: U.S. and Selected Foreign Turbine Aircraft Accidents, 1964-1974

    DTIC Science & Technology

    1976-07-01

    1965 Summary, Pg. 11 21. 6/14/65, DC-8, , Santiago , Chile Left main landing gear brakes were locked on touchdown causing tire blowouts and a small fire... concentration of nine percent will prevent an explosion such as hat which occurred under similar ex- ternal fire test conditions in an tudnerted fuel tank. These...the inert concentration in the tanks was lost, providing more time for safe evacuation. Liquid nitrogen fuel tank inerting technology is presently

  9. Pb-210 and Po-210 atmospheric releases via fly ash from oil shale-fired power plants.

    PubMed

    Vaasma, Taavi; Loosaar, Jüri; Gyakwaa, Francis; Kiisk, Madis; Özden, Banu; Tkaczyk, Alan H

    2017-03-01

    During high temperature processes in the furnace volatile and semi-volatile elements and radionuclides are partially emitted to the environment, depending on their chemical form in the original fuel, the technological set-up of the combustion system, and the prevailing combustion conditions. Two of the world's largest oil shale-fired power plants (PPs) have been operational in Estonia from the 1960s, during which time creation of significant environmental emissions and waste containing naturally occurring radionuclides has occurred. Pb-210 and 210 Po are considered natural radionuclides with the highest emission rates from PPs and possess elevated potential radiation exposure risks to humans and the environment. These radionuclides have the highest activity concentration values in fine ash fractions, especially in fractions remaining below 2.5 μm. To determine the activity concentrations of 210 Pb and 210 Po in the PPs' outlet, sampling was conducted from boilers operating on pulverized fuel (PF) technology with novel integrated desulphurization (NID) system and bag filters as well as with electrostatic precipitators (ESPs). The 210 Pb and 210 Po activity concentrations remained around 300 Bq kg -1 for the NID system compared to 60-80 Bq kg -1 in the ESP system. The dominant ash fraction in both systems was PM2.5, constituting over 50% of the fly ash mass collected from the outlet. The authors estimate that the total atmospherically emitted activity for the modernized PPs remains dominantly below 1% of the activity that is inserted via fuel. The implementation of higher efficiency purifications systems has significantly reduced the negative effect of these PPs. Based on annually emitted fly ash and boilers' working hours, the 210 Pb and 210 Po activity released relative to energy production were up to 68.3 kBq GWh el -1 for 210 Pb and 64.6 kBq GWh el -1 for 210 Po. These values are 1 to 2 orders of magnitude lower compared to the situation in the 1980s. These findings represent the first publicly available quantitative results estimating the 210 Po emissions from large oil shale-fired PPs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Synergistic interactions between leaf beetle herbivory and fire enhance tamarisk (Tamarix spp.) mortality

    USGS Publications Warehouse

    Drus, Gail M.; Dudley, Tom L.; Antonio, Carla M.; Even, Thomas J.; Brooks, Matt L.; Matchett, J.R.

    2014-01-01

    The combined effects of herbivory and fire on plant mortality were investigated using prescribed burns of tamarisk (Tamarix ramosissima Lebed) exposed to herbivory by the saltcedar leaf beetle (Chrysomelidae: Diorhabda carinulata Desbrocher). Tamarix stands in the Humboldt Sink (NV, USA) were divided into three treatments: summer burn (August 2006), fall burn (October 2006) and control (unburned), and litter depth was manipulated to vary fire intensity within burn seasons. A gradient of existing herbivory impact was described with three plant condition metrics prior to fire: reduced proportions of green canopy, percent root crown starch sampled at the height of the growing season (August 2006), and percent root crown starch measured during dormancy (December 2006). August root crown starch concentration and proportion green canopy were strongly correlated, although the proportion green canopy predicted mortality better than August root crown starch. December root crown starch concentration was more depleted in unburned trees and in trees burned during the summer than in fall burn trees. Mortality in summer burned trees was higher than fall burned trees due to higher fire intensity, but December root crown starch available for resprouting in the spring was also lower in summer burned trees. The greatest mortality was observed in trees with the lowest December root crown starch concentration which were exposed to high fire intensity. Disproportionate changes in the slope and curvature of prediction traces as fire intensity and December starch reach reciprocal maximum and minimum levels indicate that beetle herbivory and fire intensity are synergistic.

  11. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...

  12. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors; actuation of fire...

  13. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  14. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  15. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  16. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  17. Semivolatile Particulate Organic Material Southern Africa during SAFARI 2000

    NASA Technical Reports Server (NTRS)

    Eatough, D. J.; Eatough, N. L.; Pang, Y.; Sizemore, S.; Kirchstetter, T. W.; Novakov, T.

    2005-01-01

    During August and September 2000, the University of Washington's Cloud and Aerosol Research Group (CARG) with its Convair-580 research aircraft participated in the Southern African Fire-Atmosphere Research Initiative (SAFARI) 2000 field study in southern Africa. Aboard this aircraft was a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS), which was used to determine semivolatile particulate material with a diffusion denuder sampler. Denuded quartz filters and sorbent beds in series were used to measure nonvolatile and semivolatile materials, respectively. Results obtained with the PC-BOSS are compared to those obtained with conventional quartz-quartz and Teflon-quartz filter pack samplers. Various 10-120 min integrated samples were collected during flights through the h e troposphere, in the atmospheric boundary layer, and in plumes from savanna fires. Significant fine particulate semivolatile organic compounds (SVOC) were found in all samples. The SVOC was not collected by conventional filter pack samplers and therefore would not have been determined in previous studies that used only filter pack samplers. The SVOC averaged 24% of the fine particulate mass in emissions from the fires and 36% of the fine particulate mass in boundary layer samples heavily impacted by aged emissions from savanna fires. Concentrations of fine particulate material in the atmospheric mixed layer heavily impacted by aged savanna frre emissions averaged 130 micrograms per cubic meter. This aerosol was 85% carbonaceous mated.

  18. Aerosols from fires: an examination of the effects on ozone photochemistry in the Western United States.

    PubMed

    Jiang, Xiaoyan; Wiedinmyer, Christine; Carlton, Annmarie G

    2012-11-06

    This study presents a first attempt to investigate the roles of fire aerosols in ozone (O(3)) photochemistry using an online coupled meteorology-chemistry model, the Weather Research and Foresting model with Chemistry (WRF-Chem). Four 1-month WRF-Chem simulations for August 2007, with and without fire emissions, were carried out to assess the sensitivity of O(3) predictions to the emissions and subsequent radiative feedbacks associated with large-scale fires in the Western United States (U.S.). Results show that decreases in planetary boundary layer height (PBLH) resulting from the radiative effects of fire aerosols and increases in emissions of nitrogen oxides (NO(x)) and volatile organic compounds (VOCs) from the fires tend to increase modeled O(3) concentrations near the source. Reductions in downward shortwave radiation reaching the surface and surface temperature due to fire aerosols cause decreases in biogenic isoprene emissions and J(NO(2)) photolysis rates, resulting in reductions in O(3) concentrations by as much as 15%. Thus, the results presented in this study imply that considering the radiative effects of fire aerosols may reduce O(3) overestimation by traditional photochemical models that do not consider fire-induced changes in meteorology; implementation of coupled meteorology-chemistry models are required to simulate the atmospheric chemistry impacted by large-scale fires.

  19. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...

  20. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample extraction smoke detection systems, watchman's supervisory systems, and combinations of these systems. (b) Automatic fire detecting systems. For the purpose of this subpart, automatic fire and smoke detecting...

  1. Tracking nitrogen oxides, nitrous acid, and nitric acid from biomass burning

    NASA Astrophysics Data System (ADS)

    Chai, J.; Miller, D. J.; Scheuer, E. M.; Dibb, J. E.; Hastings, M. G.

    2017-12-01

    Biomass burning emissions are an important source of atmospheric nitrogen oxides (NOx = NO + NO2) and nitrous acid (HONO), which play important roles in atmosphere oxidation capacity (hydroxyl radical and ozone formation) and have severe impacts on air quality and climate in the presence of sunlight and volatile organic compounds. However, tracking NOx and HONO and their chemistry in the atmosphere based on concentration alone is challenging. Isotopic analysis provides a potential tracking tool. In this study, we measured the nitrogen isotopic composition (δ15N) of NOx (NO + NO2) and HONO, and soluble HONO and HNO3 during the Fire Influence on Regional and Global Environments Experiment (FIREX) laboratory experiments at the Missoula Fire Laboratory. Our newly developed and validated annular denuder system (ADS) enabled us to effectively trap HONO prior to a NOx collection system in series for isotopic analysis. In total we investigated 25 "stack" fires of various biomass materials where the emissions were measured within a few seconds of production by the fire. HONO concentration was measured in parallel using mist chamber/ion chromatography (MC/IC). The recovered mean HONO concentrations from ADS during the burn of each fire agree well with that measured via MC/IC. δ15N-NOx ranged from -4.3 ‰ to + 7.0 ‰ with a median of 0.7 ‰. Combined with a similar, recent study by our group [Fibiger et al., ES&T, 2017] the δ15N-NOx follows a linear relationship with δ15N-biomass (δ15N-NOx =0.94 x δ15N-biomass +1.98; R2=0.72). δ15N-HONO ranged from -5.3 to +8.3 ‰ with a median of 1.4 ‰. While both HONO and NOx are sourced from N in the biomass fuel, the secondary formation of HONO likely induces fractionation of the N that leads to the difference between δ15N-NOx and δ15N-HONO. We found a correlation of δ15N-HONO= 0.86 x δ15N-NOx + 0.52 (R2=0.55), which can potentially be used to track the chemistry of HONO formation following fire emissions. The methods used in this study will be further applied in field studies, to quantitatively track NOx and HONO in Western US wildfire plumes and their impact on the oxidation chemistry of the atmosphere.

  2. Analysis of NASA JP-4 fire tests data and development of a simple fire model

    NASA Technical Reports Server (NTRS)

    Raj, P.

    1980-01-01

    The temperature, velocity and species concentration data obtained during the NASA fire tests (3m, 7.5m and 15m diameter JP-4 fires) were analyzed. Utilizing the data analysis, a sample theoretical model was formulated to predict the temperature and velocity profiles in JP-4 fires. The theoretical model, which does not take into account the detailed chemistry of combustion, is capable of predicting the extent of necking of the fire near its base.

  3. Wildfire smoke exposure and cardiopulmonary hospitalizations among those over age 65 in the United States

    EPA Science Inventory

    Background: The health implications of excess PM2.5 due to wildland fire smoke are not well understood. Very few studies have assessed the effect of wildland fire smoke from multiple fires across the US. Methods: We estimated daily concentrations of PM2.5 due to wildland fire smo...

  4. Characteristics of an open-cut coal mine fire pollution event

    NASA Astrophysics Data System (ADS)

    Reisen, Fabienne; Gillett, Rob; Choi, Jason; Fisher, Gavin; Torre, Paul

    2017-02-01

    On 9 February 2014, embers from a nearby grass/shrub fire spotted into an unused part of the Hazelwood open-cut brown coal mine located in the Latrobe Valley of Victoria, Australia and started a fire that spread rapidly and extensively throughout the mine under strong south-westerly winds and burned over a period of 45 days. The close proximity of the town to the coal mine and the low buoyancy of the smoke plume led to the accumulation of dense smoke levels in the township of Morwell (population of 14,000) particularly under south-westerly winds. A maximum daily PM2.5 concentration of 731 μg m-3 and 8-h CO concentration of 33 ppm were measured at Morwell South, the closest residential area located approximately 500 m from the mine. These concentrations were significantly higher than national air quality standards. Air quality monitoring undertaken in the Latrobe Valley showed that smoke from the Hazelwood mine fire affected a wide area, with particle air quality standards also exceeded in Traralgon (population of 25,000) located approximately 13 km from the mine. Pollutant levels were significantly elevated in February, decreased in March once the fire abated and then returned to background levels once the fire was declared safe at the end of March. While the smoke extent was of a similar order of magnitude to other major air pollution events worldwide, a closer look at emissions ratios showed that the open combustion of lignite brown coal in the Hazelwood mine was different to open combustion of biomass, including peat. It suggested that the dominant combustion process was char combustion. While particle and carbon monoxide monitoring started approximately 4 days after the fire commenced when smoke levels were very high, targeted monitoring of air toxics only began on 26 February (17 days after the fire) when smoke levels had subsided. Limited research on emission factors from open-cut coal mine fires make it difficult to assess the likely concentrations of air toxics emitted during the initial more intense period of the fire.

  5. Influence of the Sostanj coal-fired thermal power plant on mercury and methyl mercury concentrations in Lake Velenje, Slovenia

    PubMed

    Kotnik; Horvat; Mandic; Logar

    2000-10-02

    Lake Velenje is located in one of the most polluted regions in Slovenia, the Salek Valley. The major source of pollution in the valley is the coal-fired thermal power plant in Sostanj (STPP, capacity 775 MW). It has five separate units. All units have electrostatic precipitators for fly ash removal. Unit 4 also has installed a wet flue gas desulfurisation system (FGD system). Total mercury (THg) concentrations were measured in lignite, slag and ash samples from the STPP. In flue gas, different mercury species (THg, MeHg, Hg2+, Hg0) were determined separately for unit 4 and unit 5 which use different flue gas cleaning technology. Mercury and methyl mercury (MeHg) concentrations were also measured in lake water at different depths, in inflow water, outflow water, rain, snow and lake sediments in order to establish the influence of the power plant on the lake. Most mercury emitted from the power plant is in the elemental form. The ratio between oxidised and elemental Hg depends on the flue gas cleaning technology. Mass balance calculations have been performed for the STPP. The results show that the major sources of mercury in Lake Velenje are wet deposition and lake inflows. Total and MeHg concentrations in the water column are very low and can be compared to other non-contaminated freshwater lakes in the world.

  6. Large-scale, thick, self-assembled, nacre-mimetic brick-walls as fire barrier coatings on textiles

    PubMed Central

    Das, Paramita; Thomas, Helga; Moeller, Martin; Walther, Andreas

    2017-01-01

    Highly loaded polymer/clay nanocomposites with layered structures are emerging as robust fire retardant surface coatings. However, time-intensive sequential deposition processes, e.g. layer-by-layer strategies, hinders obtaining large coating thicknesses and complicates an implementation into existing technologies. Here, we demonstrate a single-step, water-borne approach to prepare thick, self-assembling, hybrid fire barrier coatings of sodium carboxymethyl cellulose (CMC)/montmorillonite (MTM) with well-defined, bioinspired brick-wall nanostructure, and showcase their application on textile. The coating thickness on the textile is tailored using different concentrations of CMC/MTM (1–5 wt%) in the coating bath. While lower concentrations impart conformal coatings of fibers, thicker continuous coatings are obtained on the textile surface from highest concentration. Comprehensive fire barrier and fire retardancy tests elucidate the increasing fire barrier and retardancy properties with increasing coating thickness. The materials are free of halogen and heavy metal atoms, and are sourced from sustainable and partly even renewable building blocks. We further introduce an amphiphobic surface modification on the coating to impart oil and water repellency, as well as self-cleaning features. Hence, our study presents a generic, environmentally friendly, scalable, and one-pot coating approach that can be introduced into existing technologies to prepare bioinspired, thick, fire barrier nanocomposite coatings on diverse surfaces. PMID:28054589

  7. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  8. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  9. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  10. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  11. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  12. Lidar and aircraft studies of deep Cirrus systems from the 1986 FIRE IFO

    NASA Technical Reports Server (NTRS)

    Sassen, Kenneth; Heymsfield, Andrew J.; Knight, Nancy C.

    1990-01-01

    Several NCAR King Air flight missions were conducted during the Wisconsin FIRE IFO experiment in support of the University of Utah polarization lidar observations of deep cirrus cloud systems at the Wausau ground site. Data collected from four cirrus systems are included in this analysis, including those of 22 and 28 October, and 1 and 2 November. Lidar data were generally obtained at 2 min intervals in the zenith direction over observation periods that ranged from approximately 4 to 10 h, bracketing the aircraft missions. The data were processed to yield height-time (HTI) displays of lidar linear depolarization ratio sigma and relative range-normalized return power P. King Air operations consisted of a combination of rapid profiling and Lagrangian spiral descents and stacked racetrack patterns in the vicinity of the field site. From the spiral descents are constructed vertical profiles of ice particle concentration N(sub i) and ice mass content IWC derived from PMS 2-D probe imagery and, when detected, FSSP cloud droplet concentration N(sub W) and liquid water content, LWC. Aircraft flight leg data are presented for the vertical velocity W and the same ice and water cloud content parameters. In addition, aerosol particle concentrations obtained with the ASAS probe are examined, and photographs of ice particles collected in-situ on oil-coated slides are presented to illustrate ice particle habit.

  13. Near Real{time Data Assimilation for the HYSPLIT Aerosol Dispersion Model

    NASA Astrophysics Data System (ADS)

    Kalpakis, K.; Yang, S.; Yesha, Y.

    2010-12-01

    Konstantinos Kalpakis, Shiming Yang, and Yaacov Yesha Department of Computer Science and Electrical Engineering University of Maryland Baltimore County 1000 Hilltop Circle, Baltimore, MD, U.S.A. {kalpakis, shiming1, yayeshag}@csee.umbc.edu ABSTRACT We are working on an IBM-funded project seeking to develop a prototype system for real-time plume dispersion and fire and smoke detection and monitoring. Our prototype system utilizes HYSPLIT and observation data from various sources. HYSPLIT is a model developed by NOAA's Air Resources Laboratory for forecasting aerosol trajectories, dispersion, and concentration from emission sources. It is used extensively by NOAA to routinely provide a number of data products. We develop a data assimilation system for assimilating observational data into the forecasting model in order to improve its forecasting accuracy. Our system is based on the Local Ensemble Transform Kalman Filter (LETKF) algorithm and it is computationally efficient. We evaluate our data assimilation system with real in-situ observational data, and find that our system improves upon HYSPLIT's forecast by reducing the normalized mean squared error and the bias. We are also experimenting with assimilating MODIS data with HYSPLIT model forecasts. To this end, we extrapolate ground concentrations from MODIS Aerosol Optical Depth (AOD) data. Our extrapolation approach relies on spatially localized linear regressions of aerosol concentrations from ground stations in the Air Quality System (AQS) network and MODIS AOD data. We expect that assimilating the extrapolated concentrations leads into further improvements of HYSPLIT forecasts. Furthermore, we are investigating using additional sources of in-situ and remotely sensed observations, such as GOES AOD 30-minute data, and UAV data from the Ikhana AMS fire missions. These sources provide higher spatial resolution and more frequent temporal coverage. Moreover, GOES and UAVs provide near-real time data which should be useful in improving HYSPLIT forecasts of smoke from wildfires. Currently, the Ikhana AMS fire missions team provides L1B data which are very useful in themselves, but no level 2 to the best of our knowledge. For our application, it would very useful to have an AOD data product for these datasets. A possible path for deriving AOD data the AMS sensor onboard UAVs would be to utilize the DRL code for deriving the MODIS AOD from MODIS L1B data, due to the sensor similarities. Developing such code would be very useful for wildfire smoke prediction applications. Our near real-time data assimilation system helps in bridging the gap between predictions and real-time observations, for more accurate and timely aerosol dispersion forecasts. Keywords: data assimilation, HYSPLIT, forecast model performance, real-time, ensemble Kalman filter, aerosol dispersion and concentration.

  14. 46 CFR 108.413 - Fusible element fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fusible element fire detection system. 108.413 Section... UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system. (a) A fusible element fire detection system may be installed. (b) The arrangements for the system...

  15. Fire as a Factor of Variation of Soil Respiration in Amazonia of Peru

    NASA Astrophysics Data System (ADS)

    Suarez, L.; Kruijt, B.

    2007-05-01

    Severe changes are affecting the role of Amazonia in the Earth system. One of these possible effects could be the modification of the relevance of soil in the carbon cycle. In this sense, fire is an important factor for mobilizing C from the soil to the atmosphere, mainly as CO2. This could have an important effect in the global warming. Our proposal will evaluate the variation of the soil respiration related to the seasonality and the fire effects on soils in the Amazonia of Peru and Brasil. In experimental parcels of four locations of Peru with different vegetation cover (forest and pasture), we will measure soil respiration along with the organic carbon and the microbial biomass of soils during campaigns of wet and dry seasons, with complementary measurements of soil temperature, water and nutrient content. Also, we will reproduce a fire experiment simulating local activity of "slash and burn" to evaluate fire effects. Measurements will be taken after the soil cooled and 1, 3, 5, 7 and 10 days after the fire. Additionally, the carbon stock of the subparcels will be evaluated. Evaluation of the variations of CO2 fluxes and the capacity of adaptation to fire and water content will be done through the comparisons of the different locations, type of soils and concentration of available N as an indicator of nutrient content.

  16. Long-term dynamics of soil chemical properties after a prescribed fire in a Mediterranean forest (Montgrí Massif, Catalonia, Spain).

    PubMed

    Alcañiz, M; Outeiro, L; Francos, M; Farguell, J; Úbeda, X

    2016-12-01

    This study examines the effects of a prescribed fire on soil chemical properties in the Montgrí Massif (Girona, Spain). The prescribed forest fire was conducted in 2006 to reduce understory vegetation and so prevent potential severe wildfires. Soil was sampled at a depth of 0-5cm at 42 sampling points on four separate occasions: prior to the event, immediately after, one year after and nine years after. The parameters studied were pH, electrical conductivity (EC), total carbon (C), total nitrogen (N), available phosphorus (P), potassium (K + ), calcium (Ca 2+ ) and magnesium (Mg 2+ ). All parameters (except pH) increased significantly immediately after the fire. One year after burning, some chemical parameters - namely, EC, available P and K + - had returned to their initial, or even lower, values; while others - pH and total C - continued to rise. Total N, Ca 2+ and Mg 2+ levels had fallen one year after the fire, but levels were still higher than those prior to the event. Nine years after the fire, pH, total C, total N and available P are significantly lower than pre-fire values and nutrients concentrations are now higher than at the outset but without statistical significance. The soil system, therefore, is still far from being recovered nine years later. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Extinguishing Agent for Magnesium Fire: Phases 5 and 6.

    DTIC Science & Technology

    1987-07-01

    This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases I-IV. The results of this...system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires . The specifications developed for...the agent and for the delivery system are discussed in detail. Keywords: Fire suppression, Metal fires , Fire extinguishers.

  18. Baseline intrinsic flammability of Earth's ecosystems estimated from paleoatmospheric oxygen over the past 350 million years.

    PubMed

    Belcher, Claire M; Yearsley, Jonathan M; Hadden, Rory M; McElwain, Jennifer C; Rein, Guillermo

    2010-12-28

    Atmospheric oxygen (O(2)) is estimated to have varied greatly throughout Earth's history and has been capable of influencing wildfire activity wherever fuel and ignition sources were present. Fires consume huge quantities of biomass in all ecosystems and play an important role in biogeochemical cycles. This means that understanding the influence of O(2) on past fire activity has far-reaching consequences for the evolution of life and Earth's biodiversity over geological timescales. We have used a strong electrical ignition source to ignite smoldering fires, and we measured their self-sustaining propagation in atmospheres of different oxygen concentrations. These data have been used to build a model that we use to estimate the baseline intrinsic flammability of Earth's ecosystems according to variations in O(2) over the past 350 million years (Ma). Our aim is to highlight times in Earth's history when fire has been capable of influencing the Earth system. We reveal that fire activity would be greatly suppressed below 18.5% O(2), entirely switched off below 16% O(2), and rapidly enhanced between 19-22% O(2). We show that fire activity and, therefore, its influence on the Earth system would have been high during the Carboniferous (350-300 Ma) and Cretaceous (145-65 Ma) periods; intermediate in the Permian (299-251 Ma), Late Triassic (285-201 Ma), and Jurassic (201-145 Ma) periods; and surprisingly low to lacking in the Early-Middle Triassic period between 250-240 Ma. These baseline variations in Earth's flammability must be factored into our understanding of past vegetation, biodiversity, evolution, and biogeochemical cycles.

  19. North African savanna fires and atmospheric carbon dioxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iacobellis, S.F.; Frouni, Razafimpaniolo, H.

    1994-04-20

    The effect of north African savanna fires on atmospheric CO{sub 2} is investigated using a tracer transport model. The model uses winds from operational numerical weather prediction analyses and provides CO{sub 2} concentrations as a function of space and time. After a spin-up period of several years, biomass-burning sources are added, and model experiments are run for an additional year, utilizing various estimates of CO{sub 2} sources. The various model experiments show that biomass burning in the north African savannas significantly affects CO{sub 2} concentrations in South America. The effect is more pronounced during the period from January through March,more » when biomass burning in South America is almost nonexistent. During this period, atmospheric CO{sub 2} concentrations in parts of South America typically may increase by 0.5 to 0.75 ppm at 970 mbar, the average pressure of the lowest model layer. These figures are above the probable uncertainty level, as model runs with biomass-burning sources estimated from independent studies using distinct data sets and techniques indicate. From May through September, when severe biomass burning occurs in South America, the effect of north African savanna fires over South America has become generally small at 970 mbar, but north of the equator it may be of the same magnitude or larger than the effect of South American fires. The CO{sub 2} concentration increase in the extreme northern and southern portions of South America, however, is mostly due to southern African fires, whose effect may be 2-3 times larger than the effect of South American fires at 970 mbar. Even in the central part of the continent, where local biomass-burning emissions are maximum, southern African fires contribute to at least 15% of the CO{sub 2} concentration increase at 970 mbar. 20 refs., 15 figs., 1 tab.« less

  20. Forest Fire Advanced System Technology (FFAST): A Conceptual Design for Detection and Mapping

    Treesearch

    J. David Nichols; John R. Warren

    1987-01-01

    The Forest Fire Advanced System Technology (FFAST) project is developing a data system to provide near-real-time forest fire information to fire management at the fire Incident Command Post (ICP). The completed conceptual design defined an integrated forest fire detection and mapping system that is based upon technology available in the 1990's. System component...

  1. Modeling post-fire hydro-geomorphic recovery in the Waldo Canyon Fire

    NASA Astrophysics Data System (ADS)

    Kinoshita, Alicia; Nourbakhshbeidokhti, Samira; Chin, Anne

    2016-04-01

    Wildfire can have significant impacts on watershed hydrology and geomorphology by changing soil properties and removing vegetation, often increasing runoff and soil erosion and deposition, debris flows, and flooding. Watershed systems may take several years or longer to recover. During this time, post-fire channel changes have the potential to alter hydraulics that influence characteristics such as time of concentration and increase time to peak flow, flow capacity, and velocity. Using the case of the 2012 Waldo Canyon Fire in Colorado (USA), this research will leverage field-based surveys and terrestrial Light Detection and Ranging (LiDAR) data to parameterize KINEROS2 (KINematic runoff and EROSion), an event oriented, physically-based watershed runoff and erosion model. We will use the Automated Geospatial Watershed Assessment (AGWA) tool, which is a GIS-based hydrologic modeling tool that uses commonly available GIS data layers to parameterize, execute, and spatially visualize runoff and sediment yield for watersheds impacted by the Waldo Canyon Fire. Specifically, two models are developed, an unburned (Bear Creek) and burned (Williams) watershed. The models will simulate burn severity and treatment conditions. Field data will be used to validate the burned watersheds for pre- and post-fire changes in infiltration, runoff, peak flow, sediment yield, and sediment discharge. Spatial modeling will provide insight into post-fire patterns for varying treatment, burn severity, and climate scenarios. Results will also provide post-fire managers with improved hydro-geomorphic modeling and prediction tools for water resources management and mitigation efforts.

  2. Atmospheric redistribution of reactive nitrogen and phosphorus by wildfires and implications for global carbon cycling

    NASA Astrophysics Data System (ADS)

    Randerson, J. T.; Xu, L.; Wiggins, E. B.; Chen, Y.; Riley, W. J.; Mekonnen, Z. A.; Pellegrini, A.; Mahowald, N. M.

    2017-12-01

    Fires are an important process regulating the redistribution of nutrients within terrestrial ecosystems. Frequently burning ecosystems such as savannas are a net source of N and P to the atmosphere each year, with atmospheric transport and dry and wet deposition increasing nutrient availability in downwind ecosystems and over the open ocean. Transport of N and P aerosols from savanna fires within the Hadley circulation contributes to nutrient deposition over tropical forests, yielding an important cross-biome nutrient transfer. Pyrodenitrification of reactive N increases with fire temperature and modified combustion efficiency, generating a global net biospheric loss of approximately 14 Tg N per year. Here we analyze atmospheric N and P redistribution using the Global Fire Emissions Database version 4s and the Accelerated Climate Modeling for Energy earth system model. We synthesize literature estimates of N and P concentrations in fire-emitted aerosols and ecosystem mass balance measurements to help constrain model estimates of these biosphere-atmosphere fluxes. In our analysis, we estimate the fraction of terrestrial net primary production (NPP) that is sustained by fire-emitted P and reactive N from upwind ecosystems. We then evaluate how recent global declines in burned area in savanna and grassland ecosystems may be changing nutrient availability in downwind ecosystems.

  3. An analysis of effects of San Diego wildfire on ambient air quality.

    PubMed

    Viswanathan, Shekar; Eria, Luis; Diunugala, Nimal; Johnson, Jeffrey; McClean, Christopher

    2006-01-01

    The impact of major gaseous and particulate pollutants emitted by the wildfire of October 2003 on ambient air quality and health of San Diego residents before, during, and after the fire are analyzed using data available from the San Diego County Air Pollution Control District and California Air Resources Board. It was found that fine particulate matter (PM) levels exceeded the federal daily 24-hr average standard during the fire. There was a slight increase in some of the gaseous pollutants, such as carbon monoxide, which exceeded federal standards. Ozone (O3) precursors, such as total hydrocarbons and methane gases, experienced elevated concentration during the fire. Fortunately, the absence of sunlight because of the cloud of thick smoke that covered most of the county during the fire appears to have prevented the photochemical conversion of the precursor gases to harmful concentrations of O3. Statistical analysis of the compiled medical surveillance data has been used to establish correlations between pollutant levels in the region and the resultant health problems experienced by the county citizens. The study shows that the increased PM concentration above the federal standard resulted in a significant increase in hospital emergency room visits for asthma, respiratory problems, eye irritation, and smoke inhalation. On the basis of the findings, it is recommended that hospitals and emergency medical facilities engage in pre-event planning that would ensure a rapid response to an impact on the healthcare system as a result of a large wildfire and appropriate agencies engage in the use of all available meteorological forecasting resources, including real-time satellite imaging assets, to accurately forecast air quality and assist firefighting efforts.

  4. First open field measurements with a portable CO2 lidar/dial system for early forest fires detection

    NASA Astrophysics Data System (ADS)

    Gaudio, Pasquale; Gelfusa, Michela; Lupelli, Ivan; Malizia, Andrea; Moretti, Alessandro; Richetta, Maria; Serafini, Camilla; Bellecci, Carlo

    2011-11-01

    Lidar and dial are well established methods to explore the atmosphere. Different groups have already shown experimentally the possibility to measure the density variation of aerosol and particulate in the atmosphere due to plumes emitted in forest fires with this kind of systems. The aim of the present work is to demonstrate the capabilities of our mobile Lidar system, based on a CO2 laser, to detect forest fires and minimizing false alarms. For this purpose, our system can be operated in both lidar and dial configurations in sequence. The first Lidar measurement is performed to evaluate the variation of the local density into the atmosphere, using a nonabsorption water wavelength 10R18 (10.571 μm). If the returned signal reports a backscattering peak, the presence of a fire is probable. To confirm this hypothesis, a second dial measurement is carried out to reveal a second component emitted during the combustion process. The chosen second component is water vapour, which is, as it is well-known, largely produced during the first combustion stage. Measuring the water concentration peak after the detection of the aerosol density increment (referred to the standard mean atmospheric value) represents a good method to reduce false alarms with a dial system. In order to test this methodology, a first set of measurements has been performed in a field near the Engineering Faculty of the University of Rome "Tor Vergata". A quite small controlled-fire has been lighted into a box at a distance of about one kilometre from the system. The data acquired at the two wavelengths (10R18 and 10R20) have been averaged on 100 elastic backscattered Lidar signals. The first results confirm the effectiveness of the measurement strategy for reducing the number of false alarm preserving the early detection.

  5. Assessment of urinary metals following exposure to a large vegetative fire, New Mexico, 2000.

    PubMed

    Wolfe, Mitchell I; Mott, Joshua A; Voorhees, Ronald E; Sewell, C Mack; Paschal, Dan; Wood, Charles M; McKinney, Patrick E; Redd, Stephen

    2004-03-01

    In May 2000, a vegetative fire burned 47,000 acres in northern New Mexico, including 7500 acres of land administered by the Los Alamos National Laboratory. We evaluated potential human exposures from the fire. We surveyed two populations (firefighters and the general population) in four cities for urine heavy metal concentrations. Reference concentrations were based on the Third National Health and Nutrition Examination Survey (NHANES III). Multivariate linear regression assessed the association of urinary metal concentrations with smoke exposure. We also performed isotopic analysis of uranium and cesium on a subset of specimens. A total of 92 firefighters and 135 nonfirefighters participated. In both populations, urinary nickel, cesium, chromium, and uranium concentrations were greater than expected compared with NHANES III reference values. No values required immediate medical follow-up. Regression analysis demonstrated that for National Guard members, arsenic and cadmium levels were significantly related to smoke exposure, and for firefighters, cesium and arsenic levels were significantly related to exposure; however, only for cesium in National Guard members was this association in the positive direction. Isotopic analysis demonstrated that the cesium and uranium were naturally occurring. Some people had spot urine metal concentrations above nationally derived reference values, and values for some metals were associated with smoke exposure. These associations had little public health or clinical importance. Studies of exposures resulting from vegetative fires are difficult, and careful consideration should be given to the technical and communication processes at the outset of a fire exposure investigation. Recommendations for future investigations include testing as soon as possible during or after a fire, and early clinical consultation with a medical toxicologist.

  6. Effects of a fire-retardant chemical to fathead minnows in experimental streams

    USGS Publications Warehouse

    Calfee, R.D.; Little, E.E.

    2003-01-01

    Background. Each year millions of liters of fire-retardant chemicals are applied to wildfires across the nation. Recent laboratory studies with long-term fire-retardant chemicals indicate a significant photoenhanced toxicity of products containing sodium ferrocyanide corrosion inhibitors. Our objective of this study was to determine the toxicity of fire-retardant chemicals to fathead minnows during exposure in experimental outdoor streams. Methods. Stream tests were conducted to determine the potential toxicity of a pulse of exposure as might occur when fire retardant chemical is rinsed from the watershed by rainfall. Two artificial 55-meter experimental streams were dosed with different concentrations of Fire-Trol?? GTS-R, or uncontaminated for a control. Replicate groups of fathead minnows were added to screened containers (10 fish per container) and exposed to retardant chemicals in the recirculating flow of the stream for up to 6 hours. Results and Discussion. Under field conditions toxicity of GTS-R only occurred in the presence of sunlight. When GTS-R was tested on sunny days, 100% mortality occurred. However, when tested during heavily overcast conditions, no mortality occurred. Conclusions. Lethal concentrations of cyanide were measured when GTS-R with YPS exposures were conducted under sunny conditions, but not under cloudy conditions, indicating that a minimum UV level is necessary to induce toxicity as well as the release of cyanide from YPS. The toxicity observed with GTS-R was likely associated with lethal concentrations of cyanide. Rainwater runoff following applications of this fire-retardant at the recommended rate could result in lethal concentrations in small ponds and streams receiving limited water flow under sunny conditions. Recommendations and Outlook. In addition to avoiding application to aquatic habitats, it is important to consider characteristics of the treated site including soil binding affinity and erosive properties.

  7. Towards Ideal NOx and CO2 Emission Control Technology for Bio-Oils Combustion Energy System Using a Plasma-Chemical Hybrid Process

    NASA Astrophysics Data System (ADS)

    Okubo, M.; Fujishima, H.; Yamato, Y.; Kuroki, T.; Tanaka, A.; Otsuka, K.

    2013-03-01

    A pilot-scale low-emission boiler system consisting of a bio-fuel boiler and plasma-chemical hybrid NOx removal system is investigated. This system can achieve carbon neutrality because the bio-fuel boiler uses waste vegetable oil as one of the fuels. The plasma-chemical hybrid NOx removal system has two processes: NO oxidation by ozone produced from plasma ozonizers and NO2 removal using a Na2SO3 chemical scrubber. Test demonstrations of the system are carried out for mixed oils (mixture of A-heavy oil and waste vegetable oil). Stable combustion is achieved for the mixed oil (20 - 50% waste vegetable oil). Properties of flue gas—e.g., O2, CO2 and NOx—when firing mixed oils are nearly the same as those when firing heavy oil for an average flue gas flow rate of 1000 Nm3/h. NOx concentrations at the boiler outlet are 90 - 95 ppm. Furthermore, during a 300-min continuous operation when firing 20% mixed oil, NOx removal efficiency of more than 90% (less than 10 ppm NOx emission) is confirmed. In addition, the CO2 reduction when heavy oil is replaced with waste vegetable oil is estimated. The system comparison is described between the plasma-chemical hybrid NOx removal and the conventional technology.

  8. Diversity in Southwesterners' views of Forest Service fire management

    Treesearch

    P.L. Winter; G.T. Cvetkovich

    2007-01-01

    The risk of wildland fires is of significant concern in the southwestern United States. Although the Southwest has a long hi story as a fire· prone ecosystem, years of drought and insect infestation have increased fire risk. Paired with these ecological forces is the increased risk caused by the concentration of populations in the wildland urban interface (WUl),...

  9. 46 CFR 108.405 - Fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire detection system. 108.405 Section 108.405 Shipping... EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and each smoke detection system on a unit must— (1) Be approved by the Commandant; and (2) Have a visual...

  10. Effects of fire retardant on water quality

    Treesearch

    Logan A. Norris; Warren L. Webb

    1989-01-01

    Ammonium-based fire retardants are important in managing wildfires, but their use can adversely affect water quality. Their entry, fate, and impact were studied in five forest streams. Initial retardant concentrations in water approached levels which could damage fish, but no distressed fish were found. Concentrations decreased sharply with time after application and...

  11. Exposure assessment of JAVELIN missile combustion products

    NASA Astrophysics Data System (ADS)

    Lundy, Donald O.; Langford, Roland E.

    1994-02-01

    Characterization and analysis of combustion products resulting from firing the JAVELIN missile were performed. Of those combustion products analyzed, it was determined that airborne lead concentrations exceeded the OSHA PEL of 50 micrograms each time the missile was fired while in the enclosure. Since the OSHA PEL standard is based upon a continuous rather than a short-term exposures blood lead concentrations were sought to ascertain the relationship between a short duration airborne exposure and its physiological effect on the body. Blood lead levels were taken on 49 test subjects prior to various JAVELIN missile test firings. Of those 49, 21 were outfitted With personal sampling equipment to determine airborne concentrations at the Assistant Gunner and Gunner positions. Periodic blood sampling after a single exposure showed an average increase of 2.27 micrograms/dL for all test subjects. Recommendations were made to consider changes in the positioning of the enclosure inhabitants to minimize airborne lead concentrations, to limit the number of missiles fired (situation dependent), and replacement of the lead B-resorcyolate with a non-lead containing burn rate modifier for the launch motor.

  12. Effects of forest fire on soil nutrients in Turkish pine (Pinus brutia, Ten) ecosystems.

    PubMed

    Yildiz, Oktay; Esen, Derya; Sarginci, Murat; Toprak, Bulent

    2010-01-01

    Fire is a long-standing and poorly understood component of the Mediterranean forestlands in Turkey. Fire can alter plant composition, destroy biomass, alter soil physical and chemical properties and reduce soil nutrient pools. However fire can also promote productivity of certain ecosystems by mineralizing soil nutrients and promoting fast growing nitrogen fixing plant species. Fire effects on soils and ecosystems in Turkey and Mediterranean regions are not well understood. This study uses a retrospective space-for-time substitution to study soil macro-nutrient changes on sites which were burned at different times during the last 8 years. The study sites are in the Fethiye Forest Management Directorate in the western Mediterranean Sea region of Turkey. Our samples show 40% less Soil C, and cation exchange capacity (CEC) at 0-20 cm soil depth two weeks after the fire. Soil C and CEC appear to recover to pre-fire level in one year. Concentrations of Mg were significantly lower on new-burn sites, but returned to pre-fire levels in one year. Total soil N concentrations one and two years after fire were 90% higher than other sites, and total P was 9 times higher on new-burn site than averages from other sites. Some implications of these results for forest managers are discussed.

  13. 46 CFR 108.405 - Fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire detection system. 108.405 Section 108.405 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and...

  14. 46 CFR 108.401 - Fire main system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire main system. 108.401 Section 108.401 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.401 Fire main system. Each unit must have a fire main system. ...

  15. 46 CFR 108.405 - Fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire detection system. 108.405 Section 108.405 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and...

  16. 46 CFR 108.405 - Fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire detection system. 108.405 Section 108.405 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and...

  17. 46 CFR 108.401 - Fire main system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire main system. 108.401 Section 108.401 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.401 Fire main system. Each unit must have a fire main system. ...

  18. 46 CFR 108.401 - Fire main system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire main system. 108.401 Section 108.401 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.401 Fire main system. Each unit must have a fire main system. ...

  19. 46 CFR 108.405 - Fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire detection system. 108.405 Section 108.405 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and...

  20. 46 CFR 108.401 - Fire main system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire main system. 108.401 Section 108.401 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.401 Fire main system. Each unit must have a fire main system. ...

  1. 46 CFR 108.401 - Fire main system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire main system. 108.401 Section 108.401 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.401 Fire main system. Each unit must have a fire main system. ...

  2. 46 CFR 108.404 - Selection of fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Selection of fire detection system. 108.404 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a... space. (b) The fire detection system must be designed to minimize false alarms. ...

  3. Early Leakage Protection System of LPG (Liquefied Petroleum Gas) Based on ATMega 16 Microcontroller

    NASA Astrophysics Data System (ADS)

    Sriwati; Ikhsan Ilahi, Nur; Musrawati; Baco, Syarifuddin; Suyuti'Andani Achmad, Ansar; Umrianah, Ejah

    2018-04-01

    LPG (Liquefied Petroleum Gas). LPG is a hydrocarbon gas production from refineries and gas refinery with the major components of propane gas (C3H8) and butane (C4H10). Limit flame (Flammable Range) or also called gas with air. Value Lower Explosive Limit (LEL) is the minimum limit of the concentration of fuel vapor in the air which if there is no source of fire, the gas will be burned. While the value of the Upper Explosive Limit (UEL), which limits the maximum concentration of fuel vapor in the air, which if no source of fire, the gas will be burned. Protection system is a defend mechanism of human, equipment, and buildings around the protected area. Goals to be achieved in this research are to design a protection system against the consequences caused by the leakage of LPG gas based on ATmega16 microcontroller. The method used in this research is to reduce the levels of leaked LPG and turned off the power source when the leakage of LPG is on the verge of explosive limit. The design of this protection system works accurately between 200 ppm up to 10000 ppm, which is still below the threshold of explosive. Thus protecting the early result of that will result in the leakage of LPG gas.

  4. Effects of prescribed fire and post-fire rainfall on mercury mobilization and subsequent contamination assessment in a legacy mine site in Victoria, Australia.

    PubMed

    Abraham, Joji; Dowling, Kim; Florentine, Singarayer

    2018-01-01

    Prescribed fire conducted in fire-prone areas is a cost-effective choice for forest management, but it also affects many of the physicochemical and bio-geological properties of the forest soil, in a similar manner to wild fires. The aim of this study is to investigate the nature of the mercury mobilization after a prescribed fire and the subsequent temporal changes in concentration. A prescribed fire was conducted in a legacy mine site in Central Victoria, Australia, in late August 2015 and soil sample collection and analyses were carried out two days before and two days after the fire, followed by collection at the end of each season and after an intense rainfall event in September 2016. Results revealed the occurrence of mercury volatilization (8.3-97%) during the fire, and the mercury concentration displayed a significant difference (p < 0.05) before and immediately after the fire. Integrated assessment with number of pollution indices has shown that the study site is extremely contaminated with mercury during all the sampling events, and this poses a serious ecological risk due to the health impacts of mercury on human and ecosystems. In times of climate fluctuation with concomitant increase in forest fire (including prescribed fire), and subsequent precipitation and runoff, the potential for an increased amount of mercury being mobilized is of heighted significance. Therefore, it is recommended that prescribed fire should be cautiously considered as a forest management strategy in any mercury affected landscapes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Can the physical properties associated with uncertainties in the NASA MODIS AOD retrievals in the western U.S. be determined?

    NASA Astrophysics Data System (ADS)

    Loria Salazar, S. M.; Holmes, H.; Panorska, A. K.; Arnott, W. P.; Barnard, J.

    2016-12-01

    Previous investigations have used satellite remote sensing to estimate surface air pollution concentrations. While most of these studies rely on models developed for the dark-vegetated eastern U.S., they are being used in the semi-arid western U.S without modifications. These models are not robust in the western U.S. due to: 1. Irregular topography that leads to complicated boundary layer physics, 2. Pollutant mixtures, 3. Heterogeneous vertical profile of aerosol concentrations, and 4. High surface reflectance. Here, results from Nevada and California demonstrate poor AOD correlation between AERONET MODIS retrievals. Smoke from wildfires strengthened the aerosol signal, but the MODIS versus AERONET AOD correlation did not improve significantly during fire events [r2 0.17 (non-fire), r2 0.2 (fire)]. Furthermore, aerosol from fires increased the normalized mean bias (NMB) of MODIS retrievals of AOD[NMB 82% (non-fire), NMB 146% (fire)]. Additional results of this investigation found that aerosol plumes confined with the boundary layer improves MODIS AOD retrievals. However, when this condition is not met (i.e., 70% of the time downwind of mountains regions) MODIS AOD has a poor correlation and high bias with respect to AERONET AOD. Fire injection height, complicated boundary layer mixing, and entrainment disperse smoke plumes into the free atmosphere. Therefore, smoke plumes exacerbate the complex aerosol transport typical in the western U.S. and the non-linear relationship between surface pollutant concentrations and conditions aloft. This work uses stochastic methods, including regression to investigate the influence of each of these physical behaviors on the MODIS, AERONET AOD discrepancy using surrogates for each physical phenomenon, e.g., surface albedo for surface reflectance, boundary layer height and elevation for complex mixing, aerosol optical height for vertical aerosol concentrations, and fire radiative power for smoke plume injection height.

  6. Importance of transboundary transport of biomass burning emissions to regional air quality in Southeast Asia during a high fire event

    NASA Astrophysics Data System (ADS)

    Aouizerats, B.; van der Werf, G. R.; Balasubramanian, R.; Betha, R.

    2015-01-01

    Smoke from biomass and peat burning has a notable impact on ambient air quality and climate in the Southeast Asia (SEA) region. We modeled a large fire-induced haze episode in 2006 stemming mostly from Indonesia using the Weather Research and Forecasting model coupled with chemistry (WRF-Chem). We focused on the evolution of the fire plume composition and its interaction with the urbanized area of the city state of Singapore, and on comparisons of modeled and measured aerosol and carbon monoxide (CO) concentrations. Two simulations were run with WRF-Chem using the complex volatility basis set (VBS) scheme to reproduce primary and secondary aerosol evolution and concentration. The first simulation referred to as WRF-FIRE included anthropogenic, biogenic and biomass burning emissions from the Global Fire Emissions Database (GFED3) while the second simulation referred to as WRF-NOFIRE was run without emissions from biomass burning. To test model performance, we used three independent data sets for comparison including airborne measurements of particulate matter (PM) with a diameter of 10 μm or less (PM10) in Singapore, CO measurements in Sumatra, and aerosol optical depth (AOD) column observations from four satellite-based sensors. We found reasonable agreement between the model runs and both ground-based measurements of CO and PM10. The comparison with AOD was less favorable and indicated the model underestimated AOD, although the degree of mismatch varied between different satellite data sets. During our study period, forest and peat fires in Sumatra were the main cause of enhanced aerosol concentrations from regional transport over Singapore. Analysis of the biomass burning plume showed high concentrations of primary organic aerosols (POA) with values up to 600 μg m-3 over the fire locations. The concentration of POA remained quite stable within the plume between the main burning region and Singapore while the secondary organic aerosol (SOA) concentration slightly increased. However, the absolute concentrations of SOA (up to 20 μg m-3) were much lower than those from POA, indicating a minor role of SOA in these biomass burning plumes. Our results show that about 21% of the total mass loading of ambient PM10 during the July-October study period in Singapore was due to biomass and peat burning in Sumatra, but this contribution increased during high burning periods. In total, our model results indicated that during 35 days aerosol concentrations in Singapore were above the threshold of 50 μg m-3 day-1 indicating poor air quality. During 17 days this was due to fires, based on the difference between the simulations with and without fires. Local pollution in combination with recirculation of air masses was probably the main cause of poor air quality during the other 18 days, although fires from Sumatra and probably also from Kalimantan (Indonesian part of the island of Borneo) added to the enhanced PM10 concentrations. The model versus measurement comparisons highlighted that for our study period and region the GFED3 biomass burning aerosol emissions were more in line with observations than found in other studies. This indicates that care should be taken when using AOD to constrain emissions or estimate ground-level air quality. This study also shows the need for relatively high resolution modeling to accurately reproduce the advection of air masses necessary to quantify the impacts and feedbacks on regional air quality.

  7. Current status and future needs of the BehavePlus Fire Modeling System

    Treesearch

    Patricia L. Andrews

    2014-01-01

    The BehavePlus Fire Modeling System is among the most widely used systems for wildland fire prediction. It is designed for use in a range of tasks including wildfire behaviour prediction, prescribed fire planning, fire investigation, fuel hazard assessment, fire model understanding, communication and research. BehavePlus is based on mathematical models for fire...

  8. 14 CFR 29.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing system materials. 29... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Powerplant Fire Protection § 29.1201 Fire extinguishing system materials. (a) No materials in any fire extinguishing system...

  9. Comparison of GFED3, QFED2 and FEER1 Biomass Burning Emissions Datasets in a Global Model

    NASA Technical Reports Server (NTRS)

    Pan, Xiaohua; Ichoku, Charles; Bian, Huisheng; Chin, Mian; Ellison, Luke; da Silva, Arlindo; Darmenov, Anton

    2015-01-01

    Biomass burning contributes about 40% of the global loading of carbonaceous aerosols, significantly affecting air quality and the climate system by modulating solar radiation and cloud properties. However, fire emissions are poorly constrained in models on global and regional levels. In this study, we investigate 3 global biomass burning emission datasets in NASA GEOS5, namely: (1) GFEDv3.1 (Global Fire Emissions Database version 3.1); (2) QFEDv2.4 (Quick Fire Emissions Dataset version 2.4); (3) FEERv1 (Fire Energetics and Emissions Research version 1.0). The simulated aerosol optical depth (AOD), absorption AOD (AAOD), angstrom exponent and surface concentrations of aerosol plumes dominated by fire emissions are evaluated and compared to MODIS, OMI, AERONET, and IMPROVE data over different regions. In general, the spatial patterns of biomass burning emissions from these inventories are similar, although the strength of the emissions can be noticeably different. The emissions estimates from QFED are generally larger than those of FEER, which are in turn larger than those of GFED. AOD simulated with all these 3 databases are lower than the corresponding observations in Southern Africa and South America, two of the major biomass burning regions in the world.

  10. FIRES: Fire Information Retrieval and Evaluation System - A program for fire danger rating analysis

    Treesearch

    Patricia L. Andrews; Larry S. Bradshaw

    1997-01-01

    A computer program, FIRES: Fire Information Retrieval and Evaluation System, provides methods for evaluating the performance of fire danger rating indexes. The relationship between fire danger indexes and historical fire occurrence and size is examined through logistic regression and percentiles. Historical seasonal trends of fire danger and fire occurrence can be...

  11. Mercury emission trend influenced by stringent air pollutants regulation for coal-fired power plants in Korea

    NASA Astrophysics Data System (ADS)

    Pudasainee, Deepak; Kim, Jeong-Hun; Seo, Yong-Chil

    2009-12-01

    Regulatory control of mercury emission from anthropogenic sources has become a global concern in the recent past. Coal-fired power plants are one of the largest sources of anthropogenic mercury emission into the atmosphere. This paper summarizes the current reducing trend of mercury emission as co-beneficial effect by more stringent regulation changes to control primary air pollutants with introducing test results from the commercial coal-fired facilities and suggesting a guideline for future regulatory development in Korea. On average, mercury emission concentrations ranged 16.3-2.7 μg Sm -3, 2.4-1.1 μg Sm -3, 3.1-0.7 μg Sm -3 from anthracite coal-fired power plants equipped with electrostatic precipitator (ESP), bituminous coal-fired power plants with ESP + flue gas desulphurization (FGD) and bituminous coal-fired power plants with selective catalytic reactor (SCR) + cold side (CS) - ESP + wet FGD, respectively. Among the existing air pollution control devices, the best configuration for mercury removal in coal-fired power plants was SCR + CS - ESP + wet FGD, which were installed due to the stringent regulation changes to control primary air pollutants emission such as SO 2, NOx and dust. It was estimated that uncontrolled and controlled mercury emission from coal-fired power plants as 10.3 ton yr -1 and 3.2 ton yr -1 respectively. After the installation of ESP, FGD and SCR system, following the enforcement of the stringent regulation, 7.1 ton yr -1 of mercury emission has been reduced (nearly 69%) from coal-fired power plants as a co-benefit control. Based on the overall study, a sample guideline including emission limits were suggested which will be applied to develop a countermeasure for controlling mercury emission from coal-fired power plants.

  12. 46 CFR 108.407 - Detectors for electric fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Detectors for electric fire detection system. 108.407... DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.407 Detectors for electric fire detection system. (a) Each detector in an electric fire detection system must be located where— (1) No...

  13. 14 CFR 23.1201 - Fire extinguishing systems materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing systems materials. 23... Powerplant Powerplant Fire Protection § 23.1201 Fire extinguishing systems materials. For commuter category airplanes, the following apply: (a) No material in any fire extinguishing system may react chemically with...

  14. A mathematical model of a large open fire

    NASA Technical Reports Server (NTRS)

    Harsha, P. T.; Bragg, W. N.; Edelman, R. B.

    1981-01-01

    A mathematical model capable of predicting the detailed characteristics of large, liquid fuel, axisymmetric, pool fires is described. The predicted characteristics include spatial distributions of flame gas velocity, soot concentration and chemical specie concentrations including carbon monoxide, carbon dioxide, water, unreacted oxygen, unreacted fuel and nitrogen. Comparisons of the predictions with experimental values are also given.

  15. Effects of fire severity on nitrate mobilization in watersheds subject to chronic atmospheric deposition

    Treesearch

    P.J. Riggan; R.N. Lockwood; P.M. Jacks; C.G. Colver; F. Weirich; L.F. DeBano; J.A. Brass

    1994-01-01

    Severe fires in chaparral watersheds subject to air pollution from metropolitan Los Angeles mobilized accumulated nitrogen and caused streamwater to be polluted with nitrate at concentrations exceeding the Federal Water Quality Standard. Streamwater NO3- concentrations were elevated during peak flows, the largest of which was a debris flow that...

  16. Determination of gold in geologic materials by solvent extraction and atomic-absorption spectrometry

    USGS Publications Warehouse

    Huffman, Claude; Mensik, J.D.; Riley, L.B.

    1967-01-01

    The two methods presented for the determination of traces of gold in geologic materials are the cyanide atomic-absorption method and the fire-assay atomic-absorption method. In the cyanide method gold is leached with a sodium-cyanide solution. The monovalent gold is then oxidized to the trivalent state and concentrated by extracting into methyl isobutyl ketone prior to estimation by atomic absorption. In the fire-assay atomic-absorption method, the gold-silver bead obtained from fire assay is dissolved in nitric and hydrochloric acids. Gold is then concentrated by extracting into methyl isobutyl ketone prior to determination by atomic absorption. By either method concentrations as low as 50 parts per billion of gold can be determined in a 15-gram sample.

  17. 46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...

  18. 46 CFR 131.815 - Alarm for fixed gaseous fire-extinguishing system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm for fixed gaseous fire-extinguishing system. 131... VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Alarm for fixed gaseous fire-extinguishing system. Each alarm for a fixed gaseous fire-extinguishing system must be...

  19. 14 CFR 23.1201 - Fire extinguishing systems materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire extinguishing systems materials. 23... Powerplant Powerplant Fire Protection § 23.1201 Fire extinguishing systems materials. Link to an amendment... material in any fire extinguishing system may react chemically with any extinguishing agent so as to create...

  20. Influence of daily versus monthly fire emissions on atmospheric model applications in the tropics

    NASA Astrophysics Data System (ADS)

    Marlier, M. E.; Voulgarakis, A.; Faluvegi, G.; Shindell, D. T.; DeFries, R. S.

    2012-12-01

    Fires are widely used throughout the tropics to create and maintain areas for agriculture, but are also significant contributors to atmospheric trace gas and aerosol concentrations. However, the timing and magnitude of fire activity can vary strongly by year and ecosystem type. For example, frequent, low intensity fires dominate in African savannas whereas Southeast Asian peatland forests are susceptible to huge pulses of emissions during regional El Niño droughts. Despite the potential implications for modeling interactions with atmospheric chemistry and transport, fire emissions have commonly been input into global models at a monthly resolution. Recognizing the uncertainty that this can introduce, several datasets have parsed fire emissions to daily and sub-daily scales with satellite active fire detections. In this study, we explore differences between utilizing the monthly and daily Global Fire Emissions Database version 3 (GFED3) products as inputs into the NASA GISS-E2 composition climate model. We aim to understand how the choice of the temporal resolution of fire emissions affects uncertainty with respect to several common applications of global models: atmospheric chemistry, air quality, and climate. Focusing our analysis on tropical ozone, carbon monoxide, and aerosols, we compare modeled concentrations with available ground and satellite observations. We find that increasing the temporal frequency of fire emissions from monthly to daily can improve correlations with observations, predominately in areas or during seasons more heavily affected by fires. Differences between the two datasets are more evident with public health applications: daily resolution fire emissions increases the number of days exceeding World Health Organization air quality targets.

  1. 46 CFR 108.477 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hydrants. 108.477 Section 108.477 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.477 Fire hydrants. (a) If a fixed foam extinguishing system has outlets in a main machinery space, at least 2 fire hydrants, in addition to the fire...

  2. Fire Behavior System for the Full Range of Fire Management Needs

    Treesearch

    Richard C. Rothermel; Patricia L. Andrews

    1987-01-01

    An "integrated fire behavior/fire danger rating system" should be "seamless" to avoid requiring choices among alternate, independent systems. Descriptions of fuel moisture, fuels, and fire behavior should be standardized, permitting information to flow easily through the spectrum of fire management needs. The level of resolution depends on the...

  3. Analysis of postfire hydrology, water quality, and sediment transport for selected streams in areas of the 2002 Hayman and Hinman fires, Colorado

    USGS Publications Warehouse

    Stevens, Michael R.

    2013-01-01

    The U.S. Geological Survey (USGS) began a 5-year study in 2003 that focused on postfire stream-water quality and postfire sediment load in streams within the Hayman and Hinman fire study areas. This report compares water quality of selected streams receiving runoff from unburned areas and burned areas using concentrations and loads, and trend analysis, from seasonal data (approximately April–November) collected 2003–2007 at the Hayman fire study area, and data collected from 1999–2000 (prefire) and 2003 (postfire) at the Hinman fire study area. The water-quality data collected during this study include onsite measurements of streamflow, specific conductance, and turbidity, laboratory-determined pH, and concentrations of major ions, nutrients, organic carbon, trace elements, and suspended sediment. Postfire floods and effects on water quality of streams, lakes and reservoirs, drinking-water treatment, and the comparison of measured concentrations to applicable water quality standards also are discussed. Exceedances of Colorado water-quality standards in streams of both the Hayman and Hinman fire study areas only occurred for concentrations of five trace elements (not all trace-element exceedances occurred in every stream). Selected samples analyzed for total recoverable arsenic (fixed), dissolved copper (acute and chronic), total recoverable iron (chronic), dissolved manganese (acute, chronic, and fixed) and total recoverable mercury (chronic) exceeded Colorado aquatic-life standards.

  4. Available nitrogen: A time-based study of manipulated resource islands

    USGS Publications Warehouse

    Stubbs, Michelle M.; Pyke, David A.

    2005-01-01

    Spatial and temporal heterogeneity of available nitrogen are critical determinants of the distribution and abundance of plants and animals in ecosystems. Evidence for the resource island theory suggests that soils below tree and shrub canopies contain higher amounts of resources, including available nitrogen, than are present in interspace areas. Disturbances, such as prescribed fire and tree removal, are common management practices in shrub-woodland ecosystems, but it is not known if these practices affect resource islands. We examined temporal variation in resource islands of available nitrogen and their retention after fire and woody plant removal. From August 1997 to October 1998, soil nitrate (NO3−) and ammonium (NH4+) were measured monthly from canopy and interspace plots within four juniper-sagebrush sites along a precipitation gradient in central Oregon, USA. At each site, soil samples were collected from untreated plots, plots in which woody plants were removed, and those treated with prescribed fire in fall 1997. In burned treatments, canopy concentrations were significantly higher than interspace concentrations throughout the measurement period. Canopy NO3− and NH4+ concentrations were significantly higher on burned vs. unburned treatments for four months after fire. After woody plant removal, NO3− and NH4+ concentrations did not differ from the controls. Untreated control areas had higher NO3− and NH4+ concentrations under juniper canopies for nearly all months. Wetter sites had smaller differences between canopy and interspace concentrations through time than did the two drier sites. In relation to NO3− and NH4+ in this ecosystem, resource islands appear to be more ephemeral in wetter sites, and more pronounced following fire disturbances than in controls or those treated by woody plant removal.

  5. Mercury pollution in vegetables, grains and soils from areas surrounding coal-fired power plants

    NASA Astrophysics Data System (ADS)

    Li, Rui; Wu, Han; Ding, Jing; Fu, Weimin; Gan, Lijun; Li, Yi

    2017-05-01

    Mercury contamination in food can pose serious health risks to consumers and coal-fired power plants have been identified as the major source of mercury emissions. To assess the current state of mercury pollution in food crops grown near coal-fired power plants, we measured the total mercury concentration in vegetables and grain crops collected from farms located near two coal-fired power plants. We found that 79% of vegetable samples and 67% of grain samples exceeded the PTWI's food safety standards. The mercury concentrations of soil samples were negatively correlated with distances from the studied coal-fired power plants, and the mercury contents in lettuce, amaranth, water spinach, cowpea and rice samples were correlated with the mercury contents in soil samples, respectively. Also, the mercury concentrations in vegetable leaves were much higher than those in roots and the mercury content of vegetable leaves decreased significantly after water rinses. Our calculation suggests that probable weekly intake of mercury for local residents, assuming all of their vegetables and grains are from their own farmland, may exceed the toxicologically tolerable values allowed, and therefore long-term consumptions of these contaminated vegetables and grains may pose serious health risks.

  6. Mercury pollution in vegetables, grains and soils from areas surrounding coal-fired power plants

    PubMed Central

    Li, Rui; Wu, Han; Ding, Jing; Fu, Weimin; Gan, Lijun; Li, Yi

    2017-01-01

    Mercury contamination in food can pose serious health risks to consumers and coal-fired power plants have been identified as the major source of mercury emissions. To assess the current state of mercury pollution in food crops grown near coal-fired power plants, we measured the total mercury concentration in vegetables and grain crops collected from farms located near two coal-fired power plants. We found that 79% of vegetable samples and 67% of grain samples exceeded the PTWI’s food safety standards. The mercury concentrations of soil samples were negatively correlated with distances from the studied coal-fired power plants, and the mercury contents in lettuce, amaranth, water spinach, cowpea and rice samples were correlated with the mercury contents in soil samples, respectively. Also, the mercury concentrations in vegetable leaves were much higher than those in roots and the mercury content of vegetable leaves decreased significantly after water rinses. Our calculation suggests that probable weekly intake of mercury for local residents, assuming all of their vegetables and grains are from their own farmland, may exceed the toxicologically tolerable values allowed, and therefore long-term consumptions of these contaminated vegetables and grains may pose serious health risks. PMID:28484233

  7. Using National Ambient Air Quality Standards for fine particulate matter to assess regional wildland fire smoke and air quality management.

    PubMed

    Schweizer, Don; Cisneros, Ricardo; Traina, Samuel; Ghezzehei, Teamrat A; Shaw, Glenn

    2017-10-01

    Wildland fire is an important ecological process in the California Sierra Nevada. Personal accounts from pre-20th century describe a much smokier environment than present day. The policy of suppression beginning in the early 20th century and climate change are contributing to increased megafires. We use a single particulate monitoring site at the wildland urban interface to explore impacts from prescribed, managed, and full suppression wildland fires from 2006 to 2015 producing a contextual assessment of smoke impacts over time at the landscape level. Prescribed fire had little effect on local fine particulate matter (PM 2.5 ) air quality with readings typical of similar non-fire times; hourly and daily good to moderate Air Quality Index (AQI) for PM 2.5 , maximum hourly concentrations 21-103 μg m -3 , and mean concentrations between 7.7 and 13.2 μg m -3 . Hourly and daily AQI was typically good or moderate during managed fires with 3 h and one day reaching unhealthy while the site remained below National Ambient Air Quality Standards (NAAQS), with maximum hourly concentrations 27-244 μg m -3 , and mean concentrations 6.7-11.7 μg m -3 . The large high intensity fire in this area created the highest short term impacts (AQI unhealthy for 4 h and very unhealthy for 1 h), 11 unhealthy for sensitive days, and produced the only annual value (43.9 μg m -3 ) over the NAAQS 98th percentile for PM 2.5 (35 μg m -3 ). Pinehurst remained below the federal standards for PM 2.5 when wildland fire in the local area was managed to 7800 ha (8-22% of the historic burn area). Considering air quality impacts from smoke using the NAAQS at a landscape level over time can give land and air managers a metric for broader evaluation of smoke impacts particularly when assessing ecologically beneficial fire. Allowing managers to control the amount and timing of individual wildland fire emissions can help lessen large smoke impacts to public health from a megafire. Published by Elsevier Ltd.

  8. Fire Promotes Pollinator Visitation: Implications for Ameliorating Declines of Pollination Services

    PubMed Central

    Van Nuland, Michael E.; Haag, Elliot N.; Bryant, Jessica A. M.; Read, Quentin D.; Klein, Robert N.; Douglas, Morgan J.; Gorman, Courtney E.; Greenwell, Trey D.; Busby, Mark W.; Collins, Jonathan; LeRoy, Joseph T.; Schuchmann, George; Schweitzer, Jennifer A.; Bailey, Joseph K.

    2013-01-01

    Pollinators serve critical roles for the functioning of terrestrial ecosystems, and have an estimated annual value of over $150 billion for global agriculture. Mounting evidence from agricultural systems reveals that pollinators are declining in many regions of the world, and with a lack of information on whether pollinator communities in natural systems are following similar trends, identifying factors which support pollinator visitation and services are important for ameliorating the effects of the current global pollinator crisis. We investigated how fire affects resource structure and how that variation influences floral pollinator communities by comparing burn versus control treatments in a southeastern USA old-field system. We hypothesized and found a positive relationship between fire and plant density of a native forb, Verbesina alternifolia, as well as a significant difference in floral visitation of V. alternifolia between burn and control treatments. V. alternifolia density was 44% greater and floral visitation was 54% greater in burned treatments relative to control sites. When the density of V. alternifolia was experimentally reduced in the burn sites to equivalent densities observed in control sites, floral visitation in burned sites declined to rates found in control sites. Our results indicate that plant density is a proximal mechanism by which an imposed fire regime can indirectly impact floral visitation, suggesting its usefulness as a tool for management of pollination services. Although concerns surround the negative impacts of management, indirect positive effects may provide an important direction to explore for managing future ecological and conservation issues. Studies examining the interaction among resource concentration, plant apparency, and how fire affects the evolutionary consequences of altered patterns of floral visitation are overdue. PMID:24265787

  9. Improving satellite-driven PM2.5 models with Moderate Resolution Imaging Spectroradiometer fire counts in the southeastern U.S.

    PubMed

    Hu, Xuefei; Waller, Lance A; Lyapustin, Alexei; Wang, Yujie; Liu, Yang

    2014-10-16

    Multiple studies have developed surface PM 2.5 (particle size less than 2.5 µm in aerodynamic diameter) prediction models using satellite-derived aerosol optical depth as the primary predictor and meteorological and land use variables as secondary variables. To our knowledge, satellite-retrieved fire information has not been used for PM 2.5 concentration prediction in statistical models. Fire data could be a useful predictor since fires are significant contributors of PM 2.5 . In this paper, we examined whether remotely sensed fire count data could improve PM 2.5 prediction accuracy in the southeastern U.S. in a spatial statistical model setting. A sensitivity analysis showed that when the radius of the buffer zone centered at each PM 2.5 monitoring site reached 75 km, fire count data generally have the greatest predictive power of PM 2.5 across the models considered. Cross validation (CV) generated an R 2 of 0.69, a mean prediction error of 2.75 µg/m 3 , and root-mean-square prediction errors (RMSPEs) of 4.29 µg/m 3 , indicating a good fit between the dependent and predictor variables. A comparison showed that the prediction accuracy was improved more substantially from the nonfire model to the fire model at sites with higher fire counts. With increasing fire counts, CV RMSPE decreased by values up to 1.5 µg/m 3 , exhibiting a maximum improvement of 13.4% in prediction accuracy. Fire count data were shown to have better performance in southern Georgia and in the spring season due to higher fire occurrence. Our findings indicate that fire count data provide a measurable improvement in PM 2.5 concentration estimation, especially in areas and seasons prone to fire events.

  10. Improving satellite-driven PM2.5 models with Moderate Resolution Imaging Spectroradiometer fire counts in the southeastern U.S

    PubMed Central

    Hu, Xuefei; Waller, Lance A.; Lyapustin, Alexei; Wang, Yujie; Liu, Yang

    2017-01-01

    Multiple studies have developed surface PM2.5 (particle size less than 2.5 µm in aerodynamic diameter) prediction models using satellite-derived aerosol optical depth as the primary predictor and meteorological and land use variables as secondary variables. To our knowledge, satellite-retrieved fire information has not been used for PM2.5 concentration prediction in statistical models. Fire data could be a useful predictor since fires are significant contributors of PM2.5. In this paper, we examined whether remotely sensed fire count data could improve PM2.5 prediction accuracy in the southeastern U.S. in a spatial statistical model setting. A sensitivity analysis showed that when the radius of the buffer zone centered at each PM2.5 monitoring site reached 75 km, fire count data generally have the greatest predictive power of PM2.5 across the models considered. Cross validation (CV) generated an R2 of 0.69, a mean prediction error of 2.75 µg/m3, and root-mean-square prediction errors (RMSPEs) of 4.29 µg/m3, indicating a good fit between the dependent and predictor variables. A comparison showed that the prediction accuracy was improved more substantially from the nonfire model to the fire model at sites with higher fire counts. With increasing fire counts, CV RMSPE decreased by values up to 1.5 µg/m3, exhibiting a maximum improvement of 13.4% in prediction accuracy. Fire count data were shown to have better performance in southern Georgia and in the spring season due to higher fire occurrence. Our findings indicate that fire count data provide a measurable improvement in PM2.5 concentration estimation, especially in areas and seasons prone to fire events. PMID:28967648

  11. Physical and mathematical modeling of pollutant emissions when burning peat

    NASA Astrophysics Data System (ADS)

    Vasilyev, A.; Lozhkin, V.; Tarkhov, D.; Lozhkina, O.; Timofeev, V.

    2017-11-01

    The article presents an original neural network model of CO dispersion around the experimentally simulated peat fire. It is a self-learning model considering both the measured CO concentrations in the smoke cloud and the refined coefficients of the main equation. The method is recommended for the development of air quality control and forecasting systems.

  12. Evaluation of the Oxygen Concentrator Prototypes: Pressure Swing Adsorption Prototype and Electrochemical Prototype

    NASA Technical Reports Server (NTRS)

    Gilkey, Kelly M.; Olson, Sandra L.

    2015-01-01

    An oxygen concentrator is needed to provide enriched oxygen in support of medical contingency operations for future exploration human spaceflight programs. It would provide continuous oxygen to an ill or injured crew member in a closed cabin environment. Oxygen concentration technology is being pursued to concentrate oxygen from the ambient environment so oxygen as a consumable resource can be reduced. Because oxygen is a critical resource in manned spaceflight, using an oxygen concentrator to pull oxygen out of the ambient environment instead of using compressed oxygen can provide better optimization of resources. The overall goal of this project is to develop an oxygen concentrator module that minimizes the hardware mass, volume, and power footprint while still performing at the required clinical capabilities. Should a medical event occur that requires patient oxygenation, the release of 100 percent oxygen into a small closed cabin environment can rapidly raise oxygen levels to the vehicles fire limit. The use of an oxygen concentrator to enrich oxygen from the ambient air and concentrate it to the point where it can be used for medical purposes means no oxygen is needed from the ultra-high purity (99.5+% O2) oxygen reserve tanks. By not adding oxygen from compressed tanks to the cabin environment, oxygen levels can be kept below the vehicle fire limit thereby extending the duration of care provided to an oxygenated patient without environmental control system intervention to keep the cabin oxygen levels below the fire limits. The oxygen concentrator will be a Food and Drug Administration (FDA) clearable device. A demonstration unit for the International Space Station (ISS) is planned to verify the technology and provide oxygen capability. For the ISS, the demonstration unit should not exceed 10 kg (approximately 22 lb), which is the soft stowage mass limit for launch on resupply vehicles for the ISS. The unit's size should allow for transport within the spacecraft to an ill crewmember. The user interface needs to be designed for ease of use by the local care provider and with consideration to the limited amount of training available to the astronaut corps for medical equipment and procedures.

  13. 46 CFR 78.47-17 - Fire extinguishing system controls.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Fire extinguishing system controls. 78.47-17 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-17 Fire extinguishing system controls. (a) The control cabinets or spaces containing valves or manifolds for the various fire extinguishing systems shall...

  14. 46 CFR 78.47-17 - Fire extinguishing system controls.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Fire extinguishing system controls. 78.47-17 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-17 Fire extinguishing system controls. (a) The control cabinets or spaces containing valves or manifolds for the various fire extinguishing systems shall...

  15. Comparison of crown fire modeling systems used in three fire management applications

    Treesearch

    Joe H. Scott

    2006-01-01

    The relative behavior of surface-crown fire spread rate modeling systems used in three fire management applications-CFIS (Crown Fire Initiation and Spread), FlamMap and NEXUS- is compared using fire environment characteristics derived from a dataset of destructively measured canopy fuel and associated stand characteristics. Although the surface-crown modeling systems...

  16. An Overview of FlamMap Fire Modeling Capabilities

    Treesearch

    Mark A. Finney

    2006-01-01

    Computerized and manual systems for modeling wildland fire behavior have long been available (Rothermel 1983, Andrews 1986). These systems focus on one-dimensional behaviors and assume the fire geometry is a spreading line-fire (in contrast with point or area-source fires). Models included in these systems were developed to calculate fire spread rate (Rothermel 1972,...

  17. 14 CFR 23.1195 - Fire extinguishing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing systems. 23.1195 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Powerplant Fire Protection § 23.1195 Fire extinguishing systems. (a) For commuter category airplanes, fire extinguishing...

  18. Passive fire building protection system evaluation (case study: millennium ict centre)

    NASA Astrophysics Data System (ADS)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  19. An Investigation of Size-Dependent Concentration of Trace Elements in Aerosols Emitted from the Oil-Fired Heating Plants

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Sentell, R. J.; Khandelwal, G. S.

    1976-01-01

    Aerosols emitted from two oil-fired heating plants were aerodynamically separated into eight size groups and were analyzed using the photon-induced X-ray emission (PIXE) technique. It was found that Zn, Mo, Ag, and Pb, and (to a lesser extent) Cd, have a tendency to concentrate preferentially on the smaller aerosols. All of these elements, in certain chemical forms, are known to be toxic. Zinc and molybdenum, although present in low concentrations in the parent fuels, show the strongest tendencies to be concentrated in finer aerosols. Selenium, previously reported to show a very strong tendency to concentration in finer fly ash from coal-fired power plants shows little preference for surface residence. Vanadium, which occurs in significant concentration in the oil fuels for both plants, also shows little preference for surface concentration. Even though the absolute concentrations of the toxic elements involved are well below the safety levels established by the National Institute for Occupational Safety and Health (NIOSH), it would be advisable to raise the heights of the heating-plant exhaust chimneys well above the neighborhood buildings to insure more efficient aerosol dispersal.

  20. Calcium-Induced Calcium Release during Action Potential Firing in Developing Inner Hair Cells

    PubMed Central

    Iosub, Radu; Avitabile, Daniele; Grant, Lisa; Tsaneva-Atanasova, Krasimira; Kennedy, Helen J.

    2015-01-01

    In the mature auditory system, inner hair cells (IHCs) convert sound-induced vibrations into electrical signals that are relayed to the central nervous system via auditory afferents. Before the cochlea can respond to normal sound levels, developing IHCs fire calcium-based action potentials that disappear close to the onset of hearing. Action potential firing triggers transmitter release from the immature IHC that in turn generates experience-independent firing in auditory neurons. These early signaling events are thought to be essential for the organization and development of the auditory system and hair cells. A critical component of the action potential is the rise in intracellular calcium that activates both small conductance potassium channels essential during membrane repolarization, and triggers transmitter release from the cell. Whether this calcium signal is generated by calcium influx or requires calcium-induced calcium release (CICR) is not yet known. IHCs can generate CICR, but to date its physiological role has remained unclear. Here, we used high and low concentrations of ryanodine to block or enhance CICR to determine whether calcium release from intracellular stores affected action potential waveform, interspike interval, or changes in membrane capacitance during development of mouse IHCs. Blocking CICR resulted in mixed action potential waveforms with both brief and prolonged oscillations in membrane potential and intracellular calcium. This mixed behavior is captured well by our mathematical model of IHC electrical activity. We perform two-parameter bifurcation analysis of the model that predicts the dependence of IHCs firing patterns on the level of activation of two parameters, the SK2 channels activation and CICR rate. Our data show that CICR forms an important component of the calcium signal that shapes action potentials and regulates firing patterns, but is not involved directly in triggering exocytosis. These data provide important insights into the calcium signaling mechanisms involved in early developmental processes. PMID:25762313

  1. Calcium-Induced calcium release during action potential firing in developing inner hair cells.

    PubMed

    Iosub, Radu; Avitabile, Daniele; Grant, Lisa; Tsaneva-Atanasova, Krasimira; Kennedy, Helen J

    2015-03-10

    In the mature auditory system, inner hair cells (IHCs) convert sound-induced vibrations into electrical signals that are relayed to the central nervous system via auditory afferents. Before the cochlea can respond to normal sound levels, developing IHCs fire calcium-based action potentials that disappear close to the onset of hearing. Action potential firing triggers transmitter release from the immature IHC that in turn generates experience-independent firing in auditory neurons. These early signaling events are thought to be essential for the organization and development of the auditory system and hair cells. A critical component of the action potential is the rise in intracellular calcium that activates both small conductance potassium channels essential during membrane repolarization, and triggers transmitter release from the cell. Whether this calcium signal is generated by calcium influx or requires calcium-induced calcium release (CICR) is not yet known. IHCs can generate CICR, but to date its physiological role has remained unclear. Here, we used high and low concentrations of ryanodine to block or enhance CICR to determine whether calcium release from intracellular stores affected action potential waveform, interspike interval, or changes in membrane capacitance during development of mouse IHCs. Blocking CICR resulted in mixed action potential waveforms with both brief and prolonged oscillations in membrane potential and intracellular calcium. This mixed behavior is captured well by our mathematical model of IHC electrical activity. We perform two-parameter bifurcation analysis of the model that predicts the dependence of IHCs firing patterns on the level of activation of two parameters, the SK2 channels activation and CICR rate. Our data show that CICR forms an important component of the calcium signal that shapes action potentials and regulates firing patterns, but is not involved directly in triggering exocytosis. These data provide important insights into the calcium signaling mechanisms involved in early developmental processes. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Baseline intrinsic flammability of Earth’s ecosystems estimated from paleoatmospheric oxygen over the past 350 million years

    PubMed Central

    Belcher, Claire M.; Yearsley, Jonathan M.; Hadden, Rory M.; McElwain, Jennifer C.; Rein, Guillermo

    2010-01-01

    Atmospheric oxygen (O2) is estimated to have varied greatly throughout Earth’s history and has been capable of influencing wildfire activity wherever fuel and ignition sources were present. Fires consume huge quantities of biomass in all ecosystems and play an important role in biogeochemical cycles. This means that understanding the influence of O2 on past fire activity has far-reaching consequences for the evolution of life and Earth’s biodiversity over geological timescales. We have used a strong electrical ignition source to ignite smoldering fires, and we measured their self-sustaining propagation in atmospheres of different oxygen concentrations. These data have been used to build a model that we use to estimate the baseline intrinsic flammability of Earth’s ecosystems according to variations in O2 over the past 350 million years (Ma). Our aim is to highlight times in Earth’s history when fire has been capable of influencing the Earth system. We reveal that fire activity would be greatly suppressed below 18.5% O2, entirely switched off below 16% O2, and rapidly enhanced between 19–22% O2. We show that fire activity and, therefore, its influence on the Earth system would have been high during the Carboniferous (350–300 Ma) and Cretaceous (145–65 Ma) periods; intermediate in the Permian (299–251 Ma), Late Triassic (285–201 Ma), and Jurassic (201–145 Ma) periods; and surprisingly low to lacking in the Early–Middle Triassic period between 250–240 Ma. These baseline variations in Earth’s flammability must be factored into our understanding of past vegetation, biodiversity, evolution, and biogeochemical cycles. PMID:21149686

  3. Spatial Distribution and Trend of CH4, NO2, CO and Ozone during 2003-2015 over Coal Fired Power Plants in US

    NASA Astrophysics Data System (ADS)

    de Azevedo, S. C.; Reyes, C.; Singh, R. P.

    2016-12-01

    Coal fired power plants are the sources of atmospheric pollution and poor air quality in many parts of the world especially in India and China. The greenhouse emissions from the coal fired power plants are considered as threat to the climate and human health. About 572 coal fired power plants (up to 2012) are operational, especially in the mid and eastern parts of US. We have analyzed satellite measured carbon monoxide (CO), methane (CH4), nitrogen dioxide (NO2), ozone (O3) and meteorological parameters for the period 2003-2015. In this study, we have considered 30 power plants, covering 10 x10surrounding area and over 11 regions of US in a grid of about 50 x50 to 60 x60. In general, most of the coal fired power plants show a decreasing trend of CO, whereas NO2 follow a similar trend over the power plants located in the eastern parts. Our analysis shows that the clean air act is strictly followed by the coal fired power plants in the eastern US compared to power plants located in the mid and western parts. The CH4 concentrations over the eastern parts show higher concentrations compared to mid and western regions in the period 2003-2015. Higher concentrations and seasonal variability of greenhouse gases is dependent on the prevailing meteorological conditions.

  4. Air-Quality Impacts and Intake Fraction of PM2.5 during the 2013 Rim Megafire.

    PubMed

    Navarro, Kathleen M; Cisneros, Ricardo; O'Neill, Susan M; Schweizer, Don; Larkin, Narasimhan K; Balmes, John R

    2016-11-01

    The 2013 Rim Fire was the third largest wildfire in California history and burned 257 314 acres in the Sierra Nevada Mountains. We evaluated air-quality impacts of PM 2.5 from smoke from the Rim Fire on receptor areas in California and Nevada. We employed two approaches to examine the air-quality impacts: (1) an evaluation of PM 2.5 concentration data collected by temporary and permanent air-monitoring sites and (2) an estimation of intake fraction (iF) of PM 2.5 from smoke. The Rim Fire impacted locations in the central Sierra nearest to the fire and extended to the northern Sierra Nevada Mountains of California and Nevada monitoring sites. Daily 24-h average PM 2.5 concentrations measured at 22 air monitors had an average concentration of 20 μg/m 3 and ranged from 0 to 450 μg/m 3 . The iF for PM 2.5 from smoke during the active fire period was 7.4 per million, which is slightly higher than representative iF values for PM 2.5 in rural areas and much lower than for urban areas. This study is a unique application of intake fraction to examine emissions-to-exposure for wildfires and emphasizes that air-quality impacts are not only localized to communities near large fires but can extend long distances and affect larger urban areas.

  5. Remote Sensing of Global Fire Patterns, Aerosol Optical Thickness, and Carbon Monoxide During April 1994

    NASA Technical Reports Server (NTRS)

    Christopher, Sundar A.; Wang, Min; Klich, Donna V.; Welch, Ronald M.; Nolf, Scott; Connors, Vickie S.

    1997-01-01

    Fires play a crucial role in several ecosystems. They are routinely used to burn forests in order to accommodate the needs of the expanding population, clear land for agricultural purposes, eliminate weeds and pests, regenerate nutrients in grazing and crop lands and produce energy for cooking and heating purposes. Most of the fires on earth are related to biomass burning in the tropics, although they are not confined to these latitudes. The boreal and tundra regions also experience fires on a yearly basis. The current study examines global fire patterns, Aerosol Optical Thickness (AOT) and carbon monoxide concentrations during April 9-19, 1994. Recently, global Advanced Very High Resolution Radiometer (AVHRR) data at nadir ground spatial resolution of 1 km are made available through the NASA/NOAA Pathfinder project. These data from April 9-19, 1994 are used to map fires over the earth. In summary, our analysis shows that fires from biomass burning appear to be the dominant factor for increased tropospheric CO concentrations as measured by the MAPS. The vertical transport of CO by convective activities, along with horizontal transport due to the prevailing winds, are responsible for the observed spatial distribution of CO.

  6. Future climate change drives increases in forest fires and summertime OC concentrations in the Western U.S.

    NASA Astrophysics Data System (ADS)

    Spracklen, D. V.; Logan, J. A.; Mickley, L. J.; Park, R. J.; Flannigan, M. D.; Westerling, A. L.

    2006-12-01

    Increased forest fire activity in the Western United States appears to be driven by increasing spring and summer temperatures. Here we make a first estimate of how climate-driven changes in fire activity will influence summertime organic carbon (OC) concentrations in the Western US. We use output from a general circulation model (GCM) combined with area burned regressions to predict how area burned will change between present day and 2050. Calculated area burned is used to create future emission estimates for the Western U.S. and we use a global chemical transport model (CTM) to predict future changes in OC concentrations. Stepwise linear regression is used to determine the best relationships between observed area burned for 1980- 2004 and variables chosen from temperature, relative humidity, wind speed, rainfall and drought indices from the Candaian Fire Weather Index Model. Best predictors are ecosytem dependent but typically include mean summer temperature and mean drought code. In forest ecosystems of the Western U.S. our regressions explain 50-60% of the variance in annual area burned. Between 2000 and 2050 increases in temperature and reductions in precipitation, as predicted by the GISS GCM, cause mean area burned in the western U.S. to increase by 30-55%. We use the GEOS-Chem CTM to show that these increased emissions result in an increase in summertime western U.S. OC concentrations by 55% over current concentrations. Our results show that the predicted increase in future wild fires will have important consequences for western US air quality and visibility.

  7. An uncommon case of random fire-setting behavior associated with Todd paralysis: a case report.

    PubMed

    Kanehisa, Masayuki; Morinaga, Katsuhiko; Kohno, Hisae; Maruyama, Yoshihiro; Ninomiya, Taiga; Ishitobi, Yoshinobu; Tanaka, Yoshihiro; Tsuru, Jusen; Hanada, Hiroaki; Yoshikawa, Tomoya; Akiyoshi, Jotaro

    2012-08-31

    The association between fire-setting behavior and psychiatric or medical disorders remains poorly understood. Although a link between fire-setting behavior and various organic brain disorders has been established, associations between fire setting and focal brain lesions have not yet been reported. Here, we describe the case of a 24-year-old first time arsonist who suffered Todd's paralysis prior to the onset of a bizarre and random fire-setting behavior. A case of a 24-year-old man with a sudden onset of a bizarre and random fire-setting behavior is reported. The man, who had been arrested on felony arson charges, complained of difficulties concentrating and of recent memory disturbances with leg weakness. A video-EEG recording demonstrated a close relationship between the focal motor impairment and a clear-cut epileptic ictal discharge involving the bilateral motor cortical areas. The SPECT result was statistically analyzed by comparing with standard SPECT images obtained from our institute (easy Z-score imaging system; eZIS). eZIS revealed hypoperfusion in cingulate cortex, basal ganglia and hyperperfusion in frontal cortex,. A neuropsychological test battery revealed lower than normal scores for executive function, attention, and memory, consistent with frontal lobe dysfunction. The fire-setting behavior and Todd's paralysis, together with an unremarkable performance on tests measuring executive function fifteen months prior, suggested a causal relationship between this organic brain lesion and the fire-setting behavior. The case describes a rare and as yet unreported association between random, impulse-driven fire-setting behavior and damage to the brain and suggests a disconnection of frontal lobe structures as a possible pathogenic mechanism.

  8. Did the summer 2003 forest fires in Portugal affect air quality over Europe?

    NASA Astrophysics Data System (ADS)

    Miranda, A. I.; Martins, V.; Sá, E.; Carvalho, A.; Amorim, J. H.; Borrego, C.

    2009-04-01

    A forest fire is a large-scale natural combustion process consuming various types, sizes and ages of botanical specimen growing outdoors in a defined geographical area. Although wildland fires are an integral part of ecosystems management and are essential to maintain functional ecosystems their dimensions can give rise to disastrous results. Due to the frequency of occurrence and the magnitude of effects on the environment, health, economy and security, forest fires have increasingly become a major subject of concern for decision-makers, firefighters, researchers and citizens in general. Among their consequences, is the emission of various environmentally significant gases and solid particulate matter to the atmosphere that interfere with local, regional and global phenomena in the biosphere. Smoke from forest fires contains important amounts of carbon dioxide (CO2), carbon monoxide (CO), methane (CH4), nitrogen oxides (NOx), ammonia (NH3), particulate matter (PM) (that is usually referred in terms of particles with a mean diameter less than 2.5 μm, or PM2.5, and particles with a mean diameter less than 10 μm, or PM10), non-methane hydrocarbons (NMHC) and other chemical compounds. These air pollutants can cause serious consequences to local and regional air quality by reducing visibility, contributing to smog and impairing air quality in general, thus threatening human health and ecosystems. Pollutants emitted from forest fires are transported, chemically transformed, and dispersed in the atmosphere. Although major wildfires are limited to some hundreds of hectares, their impacts, with no natural or political boundaries, can be felt and reported far beyond the physical limits of the fire spread. Depending on meteorological conditions, smoke plumes and haze layers can persist in the atmosphere for long periods of time and prevailing conditions will influence the chemical and optical characteristics of the plume. The extreme fire events occurred in the summer of 2003 in Portugal highlighted the need to better analyze the link between forest fires and air quality. Portugal faced in 2003, the worst fire season ever recorded and this is clearly reflected in the values measured by the air quality-monitoring networks. There were 4,645 fires burning 8.6% of the total Portuguese forest area. The main purpose of this paper is to evaluate the contribution of summer 2003 Portuguese fires to air quality impairment in Europe. Portuguese forest fire emissions, namely CO2, CO, CH4, PM10, PM2.5, NMHC, NOx, SO2 and NH3, were estimated throughout the summer of 2003, based on specific southern European emissions factors, on type of vegetation and area burned. LOTOS-EUROS, which is an operational 3D chemistry transport model aimed to simulate air pollution in the lower troposphere, was specifically adapted to simulate forest fire emissions. The modelling system was applied first at a continental scale (with 0.5° x 0.25°, approximately 35 km x 25 km) and then to mainland Portugal domain, using the same physics and a simple one-way nesting technique, with 17.5 km x 12.5 km horizontal resolution. The simulation period covered the entire summer, aiming to estimate hourly concentration values of gaseous and particulate pollutants levels in the air. A baseline simulation (BS) was carried out, only including the "conventional" anthropogenic and biogenic emissions, and a forest fire simulation (FS), which also considered emissions from large forest fires (area burned higher than 100 ha). Hence, forest fire emissions values were added to the anthropogenic and biogenic grid emissions, according to the fire location and assuming a uniform fire spread and a constant injection altitude in the dynamic mixing layer. The modelling system indicates a severe degradation of particulate matter and ozone (O3) concentrations due to forest fires, not only in Portugal, but also in United Kingdom, France and Spain. Modelling results were compared to background monitoring data from the European Air quality dataBase (AIRBASE). A statistical analysis was performed to evaluate the simulations results, using some statistical parameters such as the root mean square error (RMSE), the systematic error (BIAS) and the Pearson correlation coefficient (r). The model performance increased substantially when forest fire emissions were included.

  9. PAH emissions from coal combustion and waste incineration.

    PubMed

    Hsu, Wei Ting; Liu, Mei Chen; Hung, Pao Chen; Chang, Shu Hao; Chang, Moo Been

    2016-11-15

    The characteristics of PAHs that are emitted by a municipal waste incinerator (MWI) and coal-fired power plant are examined via intensive sampling. Results of flue gas sampling reveal the potential for PAH formation within the selective catalytic reduction (SCR) system of a coal-fired power plant. In the large-scale MWI, the removal efficiency of PAHs achieved with the pilot-scaled catalytic filter (CF) exceeds that achieved by activated carbon injection with a bag filter (ACI+BF) owing to the effective destruction of gas-phase contaminants by a catalyst. A significantly lower PAH concentration (1640ng/g) was measured in fly ash from a CF module than from an ACI+BF system (5650ng/g). Replacing the ACI+BF system with CF technology would significantly reduce the discharge factor (including emission and fly ash) of PAHs from 251.6 to 77.8mg/ton-waste. The emission factors of PAHs that are obtained using ACI+BF and the CF system in the MWI are 8.05 and 7.13mg/ton, respectively. However, the emission factor of MWI is significantly higher than that of coal-fired power plant (1.56mg/ton). From the perspective of total environmental management to reduce PAH emissions, replacing the original ACI+BF process with a CF system is expected to reduce environmental impact thereof. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Environmental assessment of a wood-waste-fired industrial firetube boiler. Volume 1. Technical results. Final report, January 1981-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.; Waterland, L.R.

    1987-03-01

    The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace element content determinations. Totalmore » organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.« less

  11. Aquatic Toxicity Screening of Fire Fighting Agents; 2003 Report

    DTIC Science & Technology

    2003-06-02

    Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an acute, static, range-finding...five concentrations of 3M Light Water Brand Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an...experimental foam concentrates against current Military Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam

  12. Modelling pollutants dispersion and plume rise from large hydrocarbon tank fires in neutrally stratified atmosphere

    NASA Astrophysics Data System (ADS)

    Argyropoulos, C. D.; Sideris, G. M.; Christolis, M. N.; Nivolianitou, Z.; Markatos, N. C.

    2010-02-01

    Petrochemical industries normally use storage tanks containing large amounts of flammable and hazardous substances. Therefore, the occurrence of a tank fire, such as the large industrial accident on 11th December 2005 at Buncefield Oil Storage Depots, is possible and usually leads to fire and explosions. Experience has shown that the continuous production of black smoke from these fires due to the toxic gases from the combustion process, presents a potential environmental and health problem that is difficult to assess. The goals of the present effort are to estimate the height of the smoke plume, the ground-level concentrations of the toxic pollutants (smoke, SO 2, CO, PAHs, VOCs) and to characterize risk zones by comparing the ground-level concentrations with existing safety limits. For the application of the numerical procedure developed, an external floating-roof tank has been selected with dimensions of 85 m diameter and 20 m height. Results are presented and discussed. It is concluded that for all scenarios considered, the ground-level concentrations of smoke, SO 2, CO, PAHs and VOCs do not exceed the safety limit of IDLH and there are no "death zones" due to the pollutant concentrations.

  13. Production of Peroxy Nitrates in Boreal Biomass Burning Plumes over Canada During the BORTAS Campaign

    NASA Technical Reports Server (NTRS)

    Busilacchio, Marcella; Di Carlo, Piero; Aruffo, Eleonora; Biancofiore, Fabio; Salisburgo, Cesare Dari; Giammaria, Franco; Bauguitte, Stephane; Lee, James; Moller, Sarah; Hopkins, James; hide

    2016-01-01

    The observations collected during the BOReal forest fires on Tropospheric oxidants over the Atlantic using Aircraft and Satellites (BORTAS) campaign in summer 2011 over Canada are analysed to study the impact of forest fire emissions on the formation of ozone (O3 and total peroxy nitrates (sigma)PNs, (sigma)ROONO2. The suite of measurements on board the BAe-146 aircraft, deployed in this campaign, allows us to calculate the production of O3 and of (sigma)PNs, a long-lived NOx reservoir whose concentration is supposed to be impacted by biomass burning emissions.In fire plumes, profiles of carbon monoxide (CO), which is a well-established tracer of pyrogenic emission, show concentration enhancements that are in strong correspondence with a significant increase of concentrations of (sigma)PNs, where as minimal increase of the concentrations of O3 and NO2 is observed. The (sigma)PN and O3 productions have been calculated using the rate constants of the first- and second-order react Pions of volatile organic compound (VOC) oxidation. The (sigma)PN and O3 productions have also been quantified by 0-D model simulation based on the Master Chemical Mechanism. Both methods show that in fire plumes the average production of (sigma)PNs and O3 are greater than in the background plumes, but the increase of (sigma)PN production is more pronounced than the O3 production. The average (sigma)PN production in fire plumes is from 7 to 12 times greater than in the background, whereas the average O3 production in fire plumes is from 2 to 5 times greater than in the background. These results suggest that, at least for boreal forest fires and for the measurements recorded during the BORTAS campaign,fire emissions impact both the oxidized NOy and O3;but (1)(sigma)PN production is amplified significantly more thanO3 production and (2) in the forest fire plumes the ratio between the O3 production and the (sigma)PN production is lower than the ratio evaluated in the background air masses, thus confirming that the role played by the (sigma)PNs produced during biomass burning is significant in the O3 budget. The implication of these observations is that fire emissions in some cases, for example boreal forest fires and in the conditions reported here, may influence more long-lived precursors of O3than short-lived pollutants, which in turn can be transported and eventually diluted in a wide area.

  14. Nitrogen Loads in Groundwater Entering Back Bays and Ocean from Fire Island National Seashore, Long Island, New York

    USGS Publications Warehouse

    Schubert, Christopher E.; deVries, M. Peter; Finch, Anne J.

    2010-01-01

    Fire Island is a barrier island that lies south of central Long Island, N.Y. It is about 60 km (37 mi) long and 0.5 km (1/4 mi) wide and is bounded by the Great South Bay, Narrow Bay, and Moriches Bay estuaries to the north; by the Atlantic Ocean to the south; by Fire Island Inlet to the west; and by Moriches Inlet to the east (fig. 1). Fire Island National Seashore (FIIS) encompasses a 42-km (26-mi) length of Fire Island that is bordered by Robert Moses State Park to the west and Smith Point County Park to the east (fig. 2). Interspersed throughout FIIS are 17 residential beach communities that together contain about 4,100 homes. The barrier island's summer population increases 50-fold through the arrival of summer residents and vacationers. The National Park Service (NPS) has established several facilities on the island to accommodate visitors to FIIS. About 2.2 million people visit at least one of the 17 communities and (or) Smith Point County Park, the waterways surrounding Fire Island, or a FIIS facility annually (National Park Service, 2007). Combined visitation on a peak-season weekend day can be as high as 100,000 (National Park Service, 2002). Most homes and businesses in the 17 barrier-island communities discharge untreated wastewater directly to the shallow (water-table) aquifer through private septic systems and cesspools; the NPS facilities discharge wastewater to this aquifer through leach fields and cesspools. (The community of Ocean Beach (fig. 2) has a treatment plant that discharges to tidewater.) Contaminants in sewage entering the shallow groundwater move through the flow system and are ultimately discharged to adjacent marine surface waters, where they can pose a threat to coastal habitats. A contaminant of major concern is nitrogen, which is derived from fertilizers and human waste. The continuous inflow of nitrogen to surface-water bodies can lead to increased production of phytoplankton and macroalgae, which in turn can cause oxygen depletion, decreases in size of estuarine fish and shellfish communities, and loss of submerged seagrass habitat through light limitation (Valiela and others, 1992). The FIIS boundary extends roughly 1.2 km (0.8 mi) into the back-barrier estuaries of Great South Bay, Narrow Bay, and Moriches Bay (fig. 1). Within this estuarine zone are extensive areas of seagrass, shellfish, and finfish habitat, as well as intense recreational activity (Bokuniewicz and others, 1993). Management strategies for protection of these habitats require data on (1) concentrations and movement of nutrients and other human-derived contaminants that enter the groundwater system from on-site septic systems, and (2) aquifer characteristics and groundwater flow patterns. These data can then be used in three-dimensional flow models of the shallow aquifer system to predict the rates of groundwater discharge to the marine surface waters that bound Fire Island and the concentrations of nitrogen entering these water bodies from the aquifer's discharge zones. In 2004, the U.S. Geological Survey (USGS), in cooperation with the NPS, began a 3-year investigation to (1) measure groundwater levels within four local study areas at FIIS, (2) collect groundwater samples from these areas for nutrient (nitrogen) analysis, (3) develop a three-dimensional model of the hydrologic system and adjacent saltwater bodies for groundwater-flow delineation and particle tracking, and (4) apply the results of groundwater-discharge simulations to calculate the annual nitrogen loads in these discharges, particularly those entering Great South Bay, which together with the other back bays receives an estimated 80 percent of the total groundwater discharge from Fire Island. The four areas on which the investigation focused were the communities of Kismet and Robbins Rest, the NPS Visitor Center at Watch Hill, and the undeveloped Otis Pike Fire Island High Dune Wilderness (shown in panels A, B, C, and D in fig. 2); these were

  15. Wildland fire management. Volume 2: Wildland fire control 1985-1995. [satellite information system for California fire problems

    NASA Technical Reports Server (NTRS)

    Saveker, D. R. (Editor)

    1973-01-01

    The preliminary design of a satellite plus computer earth resources information system is proposed for potential uses in fire prevention and control in the wildland fire community. Suggested are satellite characteristics, sensor characteristics, discrimination algorithms, data communication techniques, data processing requirements, display characteristics, and costs in achieving the integrated wildland fire information system.

  16. BehavePlus fire modeling system, version 5.0: Design and Features

    Treesearch

    Faith Ann Heinsch; Patricia L. Andrews

    2010-01-01

    The BehavePlus fire modeling system is a computer program that is based on mathematical models that describe wildland fire behavior and effects and the fire environment. It is a flexible system that produces tables, graphs, and simple diagrams. It can be used for a host of fire management applications, including projecting the behavior of an ongoing fire, planning...

  17. BehavePlus fire modeling system, version 4.0: User's Guide

    Treesearch

    Patricia L. Andrews; Collin D. Bevins; Robert C. Seli

    2005-01-01

    The BehavePlus fire modeling system is a program for personal computers that is a collection of mathematical models that describe fire and the fire environment. It is a flexible system that produces tables, graphs, and simple diagrams. It can be used for a multitude of fire management applications including projecting the behavior of an ongoing fire, planning...

  18. [Significance of hydrocyanic acid formation during fires].

    PubMed

    von Meyer, L; Drasch, G; Kauert, G

    1979-01-01

    Cyanide concentrations of blood samples from fire victims autopsied in the Institute of Legal Medicine, Munich, have been determined. In 25% of 48 analyzed cases cyanide concentrations from 0.52 microgram to 6.24 microgram Cyanide/ml blood have been detected. These results are compared to former studies and the higher mean level in our collective is emphasized. The importance of hydrocyanid acid in the toxicity of fire gases is evidently greater, than assumed. Hydrocyanic acid may be produced from nitrogen continaing polymers during combustion. The quote of these polymers in clothing, furniture, and also in equipment of cars is increasing. Therefore, it is necessary to take more notice of the formation of hydrocyanic acid during combustion, even though carbon monoxide is in general the main toxic agent in fire gases.

  19. Mortality due to Vegetation Fire–Originated PM2.5 Exposure in Europe—Assessment for the Years 2005 and 2008

    PubMed Central

    Kollanus, Virpi; Prank, Marje; Gens, Alexandra; Soares, Joana; Vira, Julius; Kukkonen, Jaakko; Sofiev, Mikhail; Salonen, Raimo O.; Lanki, Timo

    2016-01-01

    Background: Vegetation fires can release substantial quantities of fine particles (PM2.5), which are harmful to health. The fire smoke may be transported over long distances and can cause adverse health effects over wide areas. Objective: We aimed to assess annual mortality attributable to short-term exposures to vegetation fire–originated PM2.5 in different regions of Europe. Methods: PM2.5 emissions from vegetation fires in Europe in 2005 and 2008 were evaluated based on Moderate Resolution Imaging Spectroradiometer (MODIS) satellite data on fire radiative power. Atmospheric transport of the emissions was modeled using the System for Integrated modeLling of Atmospheric coMposition (SILAM) chemical transport model. Mortality impacts were estimated for 27 European countries based on a) modeled daily PM2.5 concentrations and b) population data, both presented in a 50 × 50 km2 spatial grid; c) an exposure–response function for short-term PM2.5 exposure and daily nonaccidental mortality; and d) country-level data for background mortality risk. Results: In the 27 countries overall, an estimated 1,483 and 1,080 premature deaths were attributable to the vegetation fire–originated PM2.5 in 2005 and 2008, respectively. Estimated impacts were highest in southern and eastern Europe. However, all countries were affected by fire-originated PM2.5, and even the lower concentrations in western and northern Europe contributed substantially (~ 30%) to the overall estimate of attributable mortality. Conclusions: Our assessment suggests that air pollution caused by PM2.5 released from vegetation fires is a notable risk factor for public health in Europe. Moreover, the risk can be expected to increase in the future as climate change proceeds. This factor should be taken into consideration when evaluating the overall health and socioeconomic impacts of these fires. Citation: Kollanus V, Prank M, Gens A, Soares J, Vira J, Kukkonen J, Sofiev M, Salonen RO, Lanki T. 2017. Mortality due to vegetation fire–originated PM2.5 exposure in Europe—assessment for the years 2005 and 2008. Environ Health Perspect 125:30–37; http://dx.doi.org/10.1289/EHP194 PMID:27472655

  20. Aquatic Toxicity Screening of Fire Fighting Agents

    DTIC Science & Technology

    2005-09-21

    Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity...Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam ( AFFF ) Liquid Concentrate, For Fresh and Sea Water (MIL SPEC AFFF ). This...extinguish liquid hydrocarbon fuel fires involving aircraft operations. Several types of foam exist including protein, fluoroprotein and aqueous film

  1. Development of a multiple gas analyzer using cavity ringdown spectroscopy for use in advanced fire detection.

    PubMed

    Fallows, Eric A; Cleary, Thomas G; Miller, J Houston

    2009-02-01

    A portable cavity ringdown spectroscopy (CRDS) apparatus was used to detect effluents from small test fires in the Fire Emulator/Detector Evaluator (FE/DE) and a small room in the Building Fire and Research Laboratory at the National Institute of Standards and Technology (NIST). The output from two lasers is combined to detect four combustion gases, CO, CO(2), HCN, and C(2)H(2), near simultaneously using CRDS. The goal of this work was to demonstrate the feasibility of using a CRDS sensor as a fire detector. Fire effluents were extracted from several test facilities and measurements of CO, CO(2), HCN, and C(2)H(2) were obtained every 25-30 s. In the FE/DE test, peak concentrations of the gases from smoldering paper were 420 parts in 10(6) (ppm) CO, 1600 ppm CO(2), 530 parts in 10(9) (ppb) HCN, and 440 ppb C(2)H(2). Peak gas concentrations from the small room were 270 ppm CO, 2100 ppm CO(2), and 310 ppb C(2)H(2).

  2. Airborne asbestos exposures associated with work on asbestos fire sleeve materials.

    PubMed

    Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D

    2011-11-01

    Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Storm Water Quality in Los Alamos Canyon following the Cerro Grande Fire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Johansen; B. Enz; B. Gallaher

    In May 2000, the Cerro Grande Fire burned about 7400 acres of forest on the Los Alamos National Laboratory (LANL) and about 10,000 acres in watersheds above LANL on Santa Fe National Forest lands. The resulting burned landscapes raised concerns of increased storm water runoff and transport of contaminants by runoff in the canyons traversing LANL. On June 2 and 3, 2000, rain fell in the Los Alamos Canyon watershed generating storm water runoff in the canyon bottom. This event was important in that it was the first significant runoff on LANL following the fire and occurred in a canyonmore » containing known legacy waste sites. Samples from this runoff were analyzed for radionuclide, metal, inorganic, and organic constituents. Results show radionuclide concentrations at or below previous (pre-fire) maximum levels at locations on LANL and downstream. However, greater concentrations of some fallout-associated radionuclides (cesium-137 and strontium-90) were seen arriving on LANL from upstream areas compared to pre-fire conditions. Tests indicate most of the radionuclides in the samples were bound to sediments, not dissolved in water. Most radionuclide concentrations in sediments were below LANL Screening Action Levels, with cesium-137 and strontium-90 as exceptions. Most radionuclide concentrations in samples taken at LANL's downstream boundary were greater than those taken upstream, indicating the presence of contributing sources on LANL. For comparison purposes, doses were calculated on a mrem per liter of unfiltered water basis for 11 radionuclides commonly associated with atmospheric fallout and with LANL operations. The maximum dose was 0.094 mrem per liter unfiltered water and was largely associated with plutonium-239/240. In contrast, all filtered samples had total doses less than 0.001 mrem per liter. Compared to past data, potential doses were not increased by the fire during this initial runoff event. Of the 25 metals tested for, seven were above pre-fire levels, including copper, lead, manganese, selenium, strontium, uranium, and zinc. However, dissolved metal concentrations did not exceed State livestock and wildlife standards. Of the 18 general chemistry parameters tested, eight exceeded historic norms, including calcium, potassium, total phosphorus, cyanide, and magnesium.« less

  4. The spatial domain of wildfire risk and response in the wildland urban interface in Sydney, Australia

    NASA Astrophysics Data System (ADS)

    Price, O. F.; Bradstock, R. A.

    2013-12-01

    In order to quantify the risks from fire at the wildland urban interface (WUI), it is important to understand where fires occur and their likelihood of spreading to the WUI. For each of the 999 fires in the Sydney region we calculated the distance between the ignition and the WUI, the fire's weather and wind direction and whether it spread to the WUI. The likelihood of burning the WUI was analysed using binomial regression. Weather and distance interacted such that under mild weather conditions, the model predicted only a 5% chance that a fire starting >2.5 km from the interface would reach it, whereas when the conditions are extreme the predicted chance remained above 30% even at distances >10 km. Fires were more likely to spread to the WUI if the wind was from the west and in the western side of the region. We examined whether the management responses to wildfires are commensurate with risk by comparing the distribution of distance to the WUI of wildfires with roads and prescribed fires. Prescribed fires and roads were concentrated nearer to the WUI than wildfires as a whole, but further away than wildfires that burnt the WUI under extreme weather conditions (high risk fires). Overall, 79% of these high risk fires started within 2 km of the WUI, so there is some argument for concentrating more management effort near the WUI. By substituting climate change scenario weather into the statistical model, we predicted a small increase in the risk of fires spreading to the WUI, but the increase will be greater under extreme weather. This approach has a variety of uses, including mapping fire risk and improving the ability to match fire management responses to the threat from each fire. They also provide a baseline from which a cost-benefit analysis of complementary fire management strategies can be conducted.

  5. The spatial domain of wildfire risk and response in the Wildland Urban Interface in Sydney, Australia

    NASA Astrophysics Data System (ADS)

    Price, O. F.; Bradstock, R. A.

    2013-09-01

    In order to quantify the risks from fire at the Wildland Urban Interface (WUI), it is important to understand where fires occur and their likelihood of spreading to the WUI. For each of 999 fires in the Sydney region we calculated the distance between the ignition and the WUI, the fire weather and wind direction and whether it spread to the WUI. The likelihood of burning the WUI was analysed using binomial regression. Weather and distance interacted such that under mild weather conditions, the model predicted only a 5% chance that a fire starting more than 2.5 km from the interface would reach it, whereas when the conditions are extreme the predicted chance remained above 30% even at distances further than 10 km. Fires were more likely to spread to the WUI if the wind was from the west and in the western side of the region. We examined whether the management responses to wildfires are commensurate with risk by comparing the distribution of distance to the WUI of wildfires with roads and prescribed fires. Prescribed fires and roads were concentrated nearer to the WUI than wildfires as a whole, but further away than wildfires that burnt the WUI under extreme weather conditions (high risk fires). 79% of these high risk fires started within 2 km of the WUI, so there is some argument for concentrating more management effort near the WUI. By substituting climate change scenario weather into the statistical model, we predicted a small increase in the risk of fires spreading to the WUI, but the increase will be greater under extreme weather. This approach has a variety of uses, including mapping fire risk and improving the ability to match fire management responses to the threat from each fire. They also provide a baseline from which a cost-benefit analysis of complementary fire management strategies can be conducted.

  6. Effects of nitrogen addition and fire on plant nitrogen use in a temperate steppe.

    PubMed

    Wei, Hai-Wei; Lü, Xiao-Tao; Lü, Fu-Mei; Han, Xing-Guo

    2014-01-01

    Plant nitrogen (N) use strategies have great implications for primary production and ecosystem nutrient cycling. Given the increasing atmospheric N deposition received by most of the terrestrial ecosystems, understanding the responses of plant N use would facilitate the projection of plant-mediated N cycling under global change scenarios. The effects of N deposition on plant N use would be affected by both natural and anthropogenic disturbances, such as prescribed fire in the grassland. We examined the effects of N addition (5.25 g N m(-2) yr(-1)) and prescribed fire (annual burning) on plant N concentrations and N use characters at both species and community levels in a temperate steppe of northern China. We found that N addition and fire independently affected soil N availability and plant N use traits. Nitrogen addition increased aboveground net primary productivity (ANPP), inorganic N, and N uptake, decreased N response efficiency (NRE), but did not affect biomass-weighed N concentrations at community level. Prescribed fire did not change the community level N concentrations, but largely decreased N uptake efficiency and NRE. At the species level, the effects of N addition and fire on plant N use were species-specific. The divergent responses of plant N use at community and species levels to N addition and fire highlight the importance of the hierarchical responses of plant N use at diverse biological organization levels to the alteration of soil N availability. This study will improve our understanding of the responses of plant-mediated N cycling to global change factors and ecosystem management strategies in the semiarid grasslands.

  7. Effect of post-fire resprouting on leaf fluctuating asymmetry, extrafloral nectar quality, and ant-plant-herbivore interactions

    NASA Astrophysics Data System (ADS)

    Alves-Silva, Estevão; Del-Claro, Kleber

    2013-06-01

    Fires in the Cerrado savanna are a severe form of disturbance, but some species are capable of resprouting afterwards. It is unknown, however, how and whether post-fire resprouting represents a stressful condition to plants and how their rapid re-growth influences both the production of biochemical compounds, and interactions with mutualistic ants. In this study, we examined the influence of post-fire resprouting on biotic interactions (ant-plant-herbivore relationships) and on plant stress. The study was performed on two groups of the extrafloral nectaried shrub Banisteriopsis campestris (Malpighiaceae); one group was recovering from fire while the other acted as control. With respect to biotic interactions, we examined whether resprouting influenced extrafloral nectar concentration (milligrams per microliter), the abundance of the ant Camponotus crassus and leaf herbivory rates. Plant stress was assessed via fluctuating asymmetry (FA) analysis, which refers to deviations from perfect symmetry in bilaterally symmetrical traits (e.g., leaves) and indicates whether species are under stress. Results revealed that FA, sugar concentration, and ant abundance were 51.7 %, 35.7 % and 21.7 % higher in resprouting plants. Furthermore, C. crassus was significantly associated with low herbivory rates, but only in resprouting plants. This study showed that post-fire resprouting induced high levels of plant stress and influenced extrafloral nectar quality and ant-herbivore relationships in B. campestris. Therefore, despite being a stressful condition to the plant, post-fire resprouting individuals had concentrated extrafloral nectar and sustained more ants, thus strengthening the outcomes of ant-plant mutualism.

  8. Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility

    DTIC Science & Technology

    1996-08-01

    CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  9. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Can the water supply for the... § 149.419 Can the water supply for the helicopter deck fire protection system be part of a fire water system? (a) The water supply for the helicopter deck fire protection system required under § 149.420 or...

  10. TPV Systems — From Research Towards Commercialisation

    NASA Astrophysics Data System (ADS)

    Bitnar, Bernd; Durisch, Wilhelm; Waser, Alfred

    2004-11-01

    An overview on the development of thermophotovoltaic (TPV) systems heated with concentrated sunlight (STPV) and with a combustion flame (CTPV) is given. Only a few experimental works on STPV are reported. Lifetime investigations of TPV emitters in solar dish concentrators were carried out. A complete STPV system reported in the literature achieved a system efficiency below 0.1 %. In contrast to these experiments we present simulations, which show that an optimised STPV system with Yb2O3 emitter and high efficient Si solar cells is able to achieve a system efficiency in the order of 30 %. Quite more experimental results are reported for CTPV systems, but a series production and commercialisation of CTPV was not achieved, so far. An application for a CTPV system is a portable electrical power supply. The highest system efficiency reported so far is 6 %. Whether this efficiency is sufficient to successfully compete with generators driven by a gas engine or a diesel motor, remains unclear. Another application for CTPV that was reported is a gas fired stove, which produces electricity in addition to heat. The application of a CTPV system for electrically autonomous domestic central heating systems could probably result in a first commercialisation of TPV. For this application, a system efficiency in the order of 1 % is sufficient. A gas fired TPV system is presented, which uses a novel foam ceramic emitter made from Yb2O3 and commercially available Si solar cells. The proof-of-concept of this prototype CTPV system could successfully be furnished. Possible applications for this CTPV system are: electrically autonomous domestic heating systems, parking heating systems for vehicles, heaters for caravans and boats or large industrial burner systems.

  11. 14 CFR 91.1415 - CAMP: Mechanical reliability reports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... failure, malfunction, or defect in an aircraft concerning— (1) Fires during flight and whether the related fire-warning system functioned properly; (2) Fires during flight not protected by related fire-warning system; (3) False fire-warning during flight; (4) An exhaust system that causes damage during flight to...

  12. 14 CFR 91.1415 - CAMP: Mechanical reliability reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... failure, malfunction, or defect in an aircraft concerning— (1) Fires during flight and whether the related fire-warning system functioned properly; (2) Fires during flight not protected by related fire-warning system; (3) False fire-warning during flight; (4) An exhaust system that causes damage during flight to...

  13. Fine root production and carbohydrate concentrations of mature longleaf pine (Pinus palustris P. Mill.) as affected by season of prescribed fire and drought

    Treesearch

    Mary Anne Sword Sayer; James D. Haywood

    2005-01-01

    The historical range of longleaf pine (Pinus palustris P. Mill) has been greatly reduced, in part, by lack of fire. Recently, the application of fire has become an accepted practice for the restoration of longleaf pine to former parts of its natural range. This study was designed to evaluate the effects of season of prescribed fire on the root growth...

  14. Evaluation of CO2, N2 and He as Fire Suppression Agents in Microgravity

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Hicks, Michael; Pettegrew, Richard

    2004-01-01

    The U.S. modules of the International Space Station use gaseous CO2 as the fire extinguishing agent. This was selected as a result of extensive experience with CO2 as a fire suppressant in terrestrial applications, trade studies on various suppressants, and experiments. The selection of fire suppressants and suppression strategies for NASA s Lunar and Martian exploration missions will be based on the same studies and normal-gravity data unless reduced gravity fire suppression data is obtained. In this study, the suppressant agent concentrations required to extinguish a flame in low velocity convective flows within the 20-sec of low gravity on the KC-135 aircraft were investigated. Suppressant gas mixtures of CO2, N2, and He with the balance being oxygen/nitrogen mixtures with either 21% or 25% O2 were used to suppress flames on a 19-mm diameter PMMA cylinder in reduced gravity. For each of the suppressant mixtures, limiting concentrations were established that would extinguish the flame at any velocity. Similarly, concentrations were established that would not extinguish the flame. The limiting concentrations were generally consistent with previous studies but did suggest that geometry had an effect on the limiting conditions. Between the extinction and non-extinction limits, the suppression characteristics depended on the extinguishing agent, flow velocity, and O2 concentration. The limiting velocity data from the CO2, He, and N2 suppressants were well correlated using an effective mixture enthalpy per mole of O2, indicating that all act via O2 displacement and cooling mechanisms. In reduced gravity, the agent concentration required to suppress the flames increased as the velocity increased, up to approximately 10 cm/s (the maximum velocity evaluated in this experiment). The effective enthalpy required to extinguish flames at velocities of 10 cm/s is approximately the same as the concentrations in normal gravity. A computational study is underway to further evaluate these findings.

  15. Acute toxicity of fire control chemicals to Daphnia magna(Straus) and Selenastrum capricornutum(Printz)

    USGS Publications Warehouse

    McDonald, Susan F.; Hamilton, Steven J.; Buhl, Kevin J.; Heisinger, James F.

    1996-01-01

    Acute toxicity tests were conducted exposingDaphnia magnaStraus (daphnid) in soft and hard reconstituted waters (hardness 42 and 162 mg/liter as CaCO3, respectively), andSelenastrum capricornutumPrintz (algae) in ASTM algal assay medium (hardness 15 mg/liter as CaCO3) to fire retardants Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F, and foam suppressants Phos-Chek WD-881 and Silv-Ex. The chemicals were slightly toxic to practically harmless to daphnids and moderately toxic to algae. Water quality did not consistently alter the toxicity of the test chemicals to daphnids. The most toxic chemical to daphnids was Silv-Ex (48-hr EC507 mg/liter in soft and hard waters), whereas the least toxic chemical to daphnids was Fire-Trol LCG-R (48-hr EC50848 mg/liter in soft water, 813 mg/liter in hard water). The most toxic chemical to algae was Fire-Trol LCG-R (96-hr IC5010 mg/liter), and the least toxic chemical was Phos-Chek D75-F (96-hr IC5079 mg/liter). Un-ionized ammonia concentrations near the EC50or IC50value in tests with the Fire-Trol compounds were frequently equal to or above reported LC50un-ionized ammonia concentrations. Un-ionized ammonia concentrations in tests with Phos-Chek D75-F were low, thus other toxic components present in the compounds probably contributed to the toxicity. When compared to the daphnids tested in ASTM soft water, the Fire-Trol compounds were most toxic to algae, whereas Phos-Chek D75-F and the foam suppressants were most toxic to daphnids. The results of these tests are comparable to those obtained from research conducted in other laboratories with the same species and similar chemicals. Accidental entry of fire-fighting chemicals into aquatic environments could adversely affect algae and aquatic invertebrates, thus disrupting ecosystem function.

  16. Smouldering Fires in the Earth System

    NASA Astrophysics Data System (ADS)

    Rein, G.

    2012-04-01

    Smouldering fires, the slow, low-temperature, flameless burning, represent the most persistent type of combustion phenomena and the longest continuously fires on Earth system. Indeed, smouldering mega-fires of peatlands occur with some frequency during the dry session in, for example, Indonesia, Canada, Russia, UK and USA. Smouldering fires propagate slowly through organic layers of the ground and can reach depth >5 m if large cracks, natural piping or channel systems exist. It threatens to release sequestered carbon deep into the soil. Once ignited, they are particularly difficult to extinguish despite extensive rains, weather changes or fire-fighting attempts, and can persist for long periods of time (months, years) spreading deep and over extensive areas. Recent figures at the global scale estimate that average annual greenhouse gas emissions from smouldering fires are equivalent to 15% of man-made emissions. These fires are difficult or impossible to detect with current remote sensing methods because the chemistry is significantly different, their thermal radiation signature is much smaller, and the plume is much less buoyant. These wildfires burn fossil fuels and thus are a carbon-positive fire phenomena. This creates feedbacks in the climate system because soil moisture deficit and self-heating are enchanted under warmer climate scenarios and lead to more frequent fires. Warmer temperatures at high latitudes are resulting in more frequent Artic fires. Unprecedented permafrost thaw is leaving large soil carbon pools exposed to smouldering fires for the fist time since millennia. Although interactions between flaming fires and the Earth system have been a central focus, smouldering fires are as important but have received very little attention. DBut differences with flaming fires are important. This paper reviews the current knowledge on smouldering fires in the Earth system regarding combustion dynamics, damage to the soil, emissions, remote sensing and feedbacks in the climate system.

  17. Formulation and performance test of palm-based foaming agent concentrate for fire extinguisher application

    NASA Astrophysics Data System (ADS)

    Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pramuhadi, G.

    2018-03-01

    The utilization of foaming agent for fire extinguisher application improves the efficiency of water as a fire extinguishing agent, lowers surface tension, and acts as a foaming agent. The formed foam cools the fire down and covers the burned material to avoid it from further contact with oxygen which may reignite the fire. This study aimed to produce and assess the performance of foaming agent concentrate from palm oil as a fire extinguisher agent. In the performance test, measurements were taken on foam stability, foaming ability, surface tension, interfacial tension, viscosity, contact angle, density, and specific gravity. The formulation was conducted by using the best produced potassium palmitate, potassium methyl ester, and sodium lauric combined with diluents, chelating agent, and other additives at various composition comparisons. The produced foaming agent concentrate was found to be in a rather paste and liquid form with viscosity of 2.34 – 253 cP. It was also found that the resulted foaming agent concentrate dissolved in water at the concentration rate of 1% had a foam stability level of 30-91%, foaming ability of 288 – 503%, surface tension of 19.68 – 25.05 dyne/cm, interfacial tension of 0.54 – 4,20 dyne/cm, viscosity of 1.00 – 1.05 cP, contact angles of 53.75 – 63.79° at 0 minute and 11.84 – 22.42 ° at minute 10, density of 0.99586 – 0.99612 g/cm3, and a specific gravity of 1.00021 – 1.00046. Based on foam stability, foaming ability, and surface tension parameters, it was concluded that NF5 and NF17 were the best formulas.Compared to the other formulas, NF5 formula had the best droplet diameter (minimum 0.14 mm) and droplet density (maximum 3056 droplets/cm2).

  18. The Tiptop coal-mine fire, Kentucky: Preliminary investigation of the measurement of mercury and other hazardous gases from coal-fire gas vents

    USGS Publications Warehouse

    Hower, J.C.; Henke, K.; O'Keefe, J.M.K.; Engle, M.A.; Blake, D.R.; Stracher, G.B.

    2009-01-01

    The Tiptop underground coal-mine fire in the Skyline coalbed of the Middle Pennsylvanian Breathitt Formation was investigated in rural northern Breathitt County, Kentucky, in May 2008 and January 2009, for the purpose of determining the concentrations of carbon dioxide (CO2), carbon monoxide (CO), and mercury (Hg) in the vent and for measuring gas-vent temperatures. At the time of our visits, concentrations of CO2 peaked at 2.0% and > 6.0% (v/v) and CO at 600 ppm and > 700 ppm during field analysis in May 2008 and January 2009, respectively. For comparison, these concentrations exceed the U.S. Occupational Safety & Health Administration (OSHA) eight-hour safe exposure limits (0.5% CO2 and 50 ppm CO), although the site is not currently mined. Mercury, as Hg0, in excess of 500 and 2100 ??g/m3, in May and January, respectively, in the field, also exceeded the OSHA eight-hour exposure limit (50 ??g/m3). Carbonyl sulfide, dimethyl sulfide, carbon disulfide, and a suite of organic compounds were determined at two vents for the first sampling event. All gases are diluted by air as they exit and migrate away from a gas vent, but temperature inversions and other meteorological conditions could lead to unhealthy concentrations in the nearby towns. Variation in gas temperatures, nearly 300 ??C during the January visit to the fire versus < 50 ??C in May, demonstrates the large temporal variability in fire intensity at the Tiptop mine. These preliminary results suggest that emissions from coal fires may be important, but additional data are required that address the reasons for significant variations in the composition, flow, and temperature of vent gases. ?? 2009 Elsevier B.V.

  19. Chemistry, toxicology, and persistence of particulates during and after the 2016 Fort McMurray Wildfires in Alberta, Canada

    NASA Astrophysics Data System (ADS)

    Kohl, L.; Chan, A. W. H.; Cooke, C. A.; Hustins, S.; Jackson, B.; Wang, S.; Jing, X.; Meng, M.

    2017-12-01

    The Horse River Fire in May 2016 forced the evacuation of 88,000 Fort McMurray residents, and led to the destruction of over 2000 houses. After re-entry to homes, there is significant concern about exposures to residual fire-derived contaminants in residential houses. Wildfire research, however, provides little guidance on how long ashes and pollutants persist in household dust after major fires. The FACET project studies the chemistry and toxicology of samples of urban and forest ashes and airborne particles collected during the fire, as well as over 500 house dust samples collected in July 2017 (14 months after the fire). Here we present results on the chemical composition of the urban and forest ash samples collected during the fire along with initial results from house dust samples. Wildfire ashes contained elevated concentrations of polycyclic aromatic hydrocarbons (PAH), heavy metals, and dioxin like compounds (DLC). Relative to EPA reference doses, As and Sb constitute the greatest non-carcinogenic health hazard, whereas PAHs Benzo(a)pyrene and Indeno(1,2,3-cd)pyrene are the most relevant carcinogens. Ashes from urban locations contained higher concentrations of heavy metals and DLC than samples collected from forested areas outside of the City of Fort McMurray. Urban samples furthermore had a greater potential for generating oxidative stress than rural samples, as determined by dithiothreitol (DTT) consumption assays. The oxidative potential was positively correlated to Al, Cu, As, and V concentrations. Airborne particulate matter samples from the smoke plume contained consistent concentrations of levoglucosan (99 ± 5 mg g-1), along with other tracers for biomass burning (free lignin monomers, retene). Together these results will serve as proxies for understanding the contribution and the persistence of fire-derived pollutants in house dust in Fort McMurray homes.

  20. Development and evaluation of a high-resolution aerosol optical depth product for the southern California region during the October 2007 wildfires

    NASA Astrophysics Data System (ADS)

    McCarthy, M. C.; Raffuse, S. M.; Dewinter, J. L.; Lurmann, F.; Craig, K. J.; Fruin, S.

    2010-12-01

    Current methods for estimating acute exposure to high levels of air pollution (e.g., particles, CO, NOx, aldehydes) during fire events require spatial interpolation over the study area using concentrations at central air quality monitors to represent the population of interest. This may inaccurately represent the magnitude of exposure because pollutant concentrations vary widely depending on the location of the fire plume, vertical mixing, and prevailing winds dispersing the pollutant. Remotely sensed datasets, such as aerosol optical depth (AOD) from the NASA MODIS instrument, can provide greater spatial coverage than ground-based air quality monitors. Past studies have shown positive correlations between AOD, a measure of aerosols in an atmospheric column, and ground-level measurements of PM2.5 and PM10 concentrations. However, current standard AOD products are not sufficient for assessing intra-urban variability due to the low spatial resolution (e.g., 10x10 km for MODIS) of datasets. In addition such products typically perform poorly with very dense smoke in the atmosphere and over reflective, semi-arid land surfaces such as southern California. A highly resolved AOD product (500m resolution) was developed for southern California during the October 2007 fires using radiance data obtained from the National Aeronautics and Space Administration (NASA) MODIS instrument. AOD was calculated at 0.55µm wavelength using a unique algorithm tailored to the southern California region and for an atmosphere dominated by biomass burning aerosols. The AOD product was compared with column measurements of AOD from surface-based AERONET sites. AOD was not predictive of surface PM during the October 2007 fires when compared to surface PM concentrations throughout southern California; R-square correlation coefficients were low. However, the relationship varied during the time period studied: correlations were weak early in the event (0.02) but improved during the later days of the event (0.3). Heavy dust episodes early in the fire event were poorly represented by the biomass-specific aerosol optical properties model. In addition, lofted smoke plumes from active fires did not mix down to the surface, resulting in high AOD column estimates and low surface PM concentrations. The aerosol was more dispersed later in the event; elevated surface PM concentrations were coincident with moderate AOD values. The case study demonstrates the challenges in using remote measurements in quantifying surface concentrations during active fire events in areas of complex terrain.

  1. How to generate and interpret fire characteristics charts for the U.S. fire danger rating system

    Treesearch

    Faith Ann Heinsch; Patricia L. Andrews; Deb Tirmenstein

    2017-01-01

    The fire characteristics chart is a graphical method of presenting U.S. National Fire Danger Rating System (NFDRS) indexes and components as well as primary surface or crown fire behavior characteristics. Computer software has been developed to produce fire characteristics charts for both fire danger and fire behavior in a format suitable for inclusion in reports and...

  2. Simulation of wind-driven dispersion of fire pollutants in a street canyon using FDS.

    PubMed

    Pesic, Dusica J; Blagojevic, Milan Dj; Zivkovic, Nenad V

    2014-01-01

    Air quality in urban areas attracts great attention due to increasing pollutant emissions and their negative effects on human health and environment. Numerous studies, such as those by Mouilleau and Champassith (J Loss Prevent Proc 22(3): 316-323, 2009), Xie et al. (J Hydrodyn 21(1): 108-117, 2009), and Yassin (Environ Sci Pollut Res 20(6): 3975-3988, 2013) focus on the air pollutant dispersion with no buoyancy effect or weak buoyancy effect. A few studies, such as those by Hu et al. (J Hazard Mater 166(1): 394-406, 2009; J Hazard Mater 192(3): 940-948, 2011; J Civ Eng Manag (2013)) focus on the fire-induced dispersion of pollutants with heat buoyancy release rate in the range from 0.5 to 20 MW. However, the air pollution source might very often be concentrated and intensive, as a consequence of the hazardous materials fire. Namely, transportation of fuel through urban areas occurs regularly, because it is often impossible to find alternative supply routes. It is accompanied with the risk of fire accident occurrences. Accident prevention strategies require analysis of the worst scenarios in which fire products jeopardize the exposed population and environment. The aim of this article is to analyze the impact of wind flow on air pollution and human vulnerability to fire products in a street canyon. For simulation of the gasoline tanker truck fire as a result of a multivehicle accident, computational fluid dynamics large eddy simulation method has been used. Numerical results show that the fire products flow vertically upward, without touching the walls of the buildings in the absence of wind. However, when the wind velocity reaches the critical value, the products touch the walls of the buildings on both sides of the street canyon. The concentrations of carbon monoxide and soot decrease, whereas carbon dioxide concentration increases with the rise of height above the street canyon ground level. The longitudinal concentration of the pollutants inside the street increases with the rise of the wind velocity at the roof level of the street canyon.

  3. 46 CFR 108.419 - Fire main capacity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.419 Fire main capacity. The diameter of the fire... pumps operating simultaneously. ...

  4. 46 CFR 108.419 - Fire main capacity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.419 Fire main capacity. The diameter of the fire... pumps operating simultaneously. ...

  5. FOCUS: a fire management planning system -- final report

    Treesearch

    Frederick W. Bratten; James B. Davis; George T. Flatman; Jerold W. Keith; Stanley R. Rapp; Theodore G. Storey

    1981-01-01

    FOCUS (Fire Operational Characteristics Using Simulation) is a computer simulation model for evaluating alternative fire management plans. This final report provides a broad overview of the FOCUS system, describes two major modules-fire suppression and cost, explains the role in the system of gaming large fires, and outlines the support programs and ways of...

  6. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  7. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  8. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  9. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  10. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  11. 46 CFR 122.612 - Fire protection equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...

  12. 46 CFR 122.612 - Fire protection equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...

  13. 46 CFR 122.612 - Fire protection equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...

  14. 46 CFR 122.612 - Fire protection equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...

  15. 46 CFR 122.612 - Fire protection equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...

  16. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  17. Estimation of postfire nutrient loss in the Florida everglades.

    PubMed

    Qian, Y; Miao, S L; Gu, B; Li, Y C

    2009-01-01

    Postfire nutrient release into ecosystem via plant ash is critical to the understanding of fire impacts on the environment. Factors determining a postfire nutrient budget are prefire nutrient content in the combustible biomass, burn temperature, and the amount of combustible biomass. Our objective was to quantitatively describe the relationships between nutrient losses (or concentrations in ash) and burning temperature in laboratory controlled combustion and to further predict nutrient losses in field fire by applying predictive models established based on laboratory data. The percentage losses of total nitrogen (TN), total carbon (TC), and material mass showed a significant linear correlation with a slope close to 1, indicating that TN or TC loss occurred predominantly through volatilization during combustion. Data obtained in laboratory experiments suggest that the losses of TN, TC, as well as the ratio of ash total phosphorus (TP) concentration to leaf TP concentration have strong relationships with burning temperature and these relationships can be quantitatively described by nonlinear equations. The potential use of these nonlinear models relating nutrient loss (or concentration) to temperature in predicting nutrient concentrations in field ash appear to be promising. During a prescribed fire in the northern Everglades, 73.1% of TP was estimated to be retained in ash while 26.9% was lost to the atmosphere, agreeing well with the distribution of TP during previously reported wild fires. The use of predictive models would greatly reduce the cost associated with measuring field ash nutrient concentrations.

  18. 14 CFR 29.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire extinguishing system materials. 29.1201 Section 29.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 29.1201 Fire extinguishing system materials. (a) No materials in any fire extinguishing system...

  19. 14 CFR 29.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire extinguishing system materials. 29.1201 Section 29.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 29.1201 Fire extinguishing system materials. (a) No materials in any fire extinguishing system...

  20. 14 CFR 25.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire extinguishing system materials. 25.1201 Section 25.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 25.1201 Fire extinguishing system materials. (a) No material in any fire extinguishing system...

  1. 14 CFR 25.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing system materials. 25.1201 Section 25.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 25.1201 Fire extinguishing system materials. (a) No material in any fire extinguishing system...

  2. 14 CFR 25.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire extinguishing system materials. 25.1201 Section 25.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 25.1201 Fire extinguishing system materials. (a) No material in any fire extinguishing system...

  3. 14 CFR 29.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire extinguishing system materials. 29.1201 Section 29.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 29.1201 Fire extinguishing system materials. (a) No materials in any fire extinguishing system...

  4. 14 CFR 25.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire extinguishing system materials. 25.1201 Section 25.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 25.1201 Fire extinguishing system materials. (a) No material in any fire extinguishing system...

  5. 14 CFR 29.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire extinguishing system materials. 29.1201 Section 29.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 29.1201 Fire extinguishing system materials. (a) No materials in any fire extinguishing system...

  6. 14 CFR 25.1201 - Fire extinguishing system materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire extinguishing system materials. 25.1201 Section 25.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Protection § 25.1201 Fire extinguishing system materials. (a) No material in any fire extinguishing system...

  7. Fire Safety in the Low-Gravity Spacecraft Environment

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1999-01-01

    Research in microgravity (low-gravity) combustion promises innovations and improvements in fire prevention and response for human-crew spacecraft. Findings indicate that material flammability and fire spread in microgravity are significantly affected by atmospheric flow rate, oxygen concentration, and diluent composition. This information can lead to modifications and correlations to standard material-assessment tests for prediction of fire resistance in space. Research on smoke-particle changes in microgravity promises future improvements and increased sensitivity of smoke detectors in spacecraft. Research on fire suppression by extinguishing agents and venting can yield new information on effective control of the rare, but serious fire events in spacecraft.

  8. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  9. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  10. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  11. Distribution and Fate of Mercury in Pulverized Bituminous Coal-Fired Power Plants in Coal Energy-Dominant Huainan City, China.

    PubMed

    Chen, Bingyu; Liu, Guijian; Sun, Ruoyu

    2016-05-01

    A better understanding on the partitioning behavior of mercury (Hg) during coal combustion in large-scale coal-fired power plants is fundamental for drafting Hg-emission control regulations. Two large coal-fired utility boilers, equipped with electrostatic precipitators (ESPs) and a wet flue gas desulfurization (WFGD) system, respectively, in coal energy-dominant Huainan City, China, were selected to investigate the distribution and fate of Hg during coal combustion. In three sampling campaigns, we found that Hg in bottom ash was severely depleted with a relative enrichment (RE) index <7 %, whereas the RE index for fly ash (9-54%) was comparatively higher and variable. Extremely high Hg was concentrated in gypsum (≤4500 ng/g), which is produced in the WFGD system. Mass balance calculation shows that the shares of Hg in bottom ash, fly ash, WFGD products (gypsum, effluents, sludge), and stack emissions were <2, 17-32, 7-22, and 54-82%, respectively. The Hg-removal efficiencies of ESPs, WFGD, and ESPs + WFGD were 17-32, 10-29, and 36-46%, respectively. The Hg-emission factor of studied boilers was in a high range of 0.24-0.29 g Hg/t coal. We estimated that Hg emissions in all Huainan coal-fired power plants varied from 1.8 Mg in 2003 to 7.3 Mg in 2010.

  12. Carbachol induces burst firing of dopamine cells in the ventral tegmental area by promoting calcium entry through L-type channels in the rat

    PubMed Central

    Zhang, Lei; Liu, Yudan; Chen, Xihua

    2005-01-01

    Enhanced activity of the central dopamine system has been implicated in many psychiatric disorders including schizophrenia and addiction. Besides terminal mechanisms that boost dopamine levels at the synapse, the cell body of dopamine cells enhances terminal dopamine concentration through encoding action potentials in bursts. This paper presents evidence that burst firing of dopamine cells in the ventral tegmental area was under cholinergic control using nystatin-perforated patch clamp recording from slice preparations. The non-selective cholinergic agonist carbachol excited the majority of recorded neurones, an action that was not affected by blocking glutamate and GABA ionotropic receptors. Twenty per cent of dopamine cells responded to carbachol with robust bursting, an effect mediated by both muscarinic and nicotinic cholinoceptors postsynaptically. Burst firing induced as such was completely dependent on calcium entry as it could be blocked by cadmium and more specifically the L-type blocker nifedipine. In the presence of the sodium channel blocker tetrodotoxin, carbachol induced membrane potential oscillation that had similar kinetics and frequency as burst firing cycles and could also be blocked by cadmium and nifedipine. Direct activation of the L-type channel with Bay K8644 induced strong bursting which could be blocked by nifedipine but not by depleting internal calcium stores. These results indicate that carbachol increases calcium entry into the postsynaptic cell through L-type channels to generate calcium-dependent membrane potential oscillation and burst firing. This could establish the L-type channel as a target for modulating the function of the central dopamine system in disease conditions. PMID:16081481

  13. Forest fire effects on mercury deposition in the boreal forest

    Treesearch

    Emma L. Witt; Randall K. Kolka; Edward A. Nater; Trent R. Wickman

    2009-01-01

    The objective of this study was to determine how forest fire effects Hg deposition to nearby landscapes impacted by smoke plumes. Hg concentrations and deposition were hypothesized to increase in throughfall and open precipitation after fire, and canopy type was hypothesized to influence the magnitude of the increase. Conifer canopies, which are better able to scavenge...

  14. Surface ozone at the Devils Postpile National Monument receptor site during low and high wildland fire years

    Treesearch

    Andrzej Bytnerowicz; Joel D. Burley; Ricardo Cisneros; Haiganoush K. Preisler; Susan Schilling; Donald Schweizer; John Ray; Deanna Dulen; Christopher Beck; Bianca Auble

    2013-01-01

    Surface ozone (O3) was measured at the Devils Postpile National Monument (DEPO), eastern Sierra Nevada Mountains, California, during the 2007 (low-fire) and 2008 (high-fire) summer seasons. While mean and median values of O3 concentrations for the 2007 and 2008 summer seasons were similar, maximum O3...

  15. Fire effects on rangeland hydrology and erosion in a steep sagebrush-dominated landscape

    Treesearch

    Frederick B. Pierson; Peter R. Robichaud; Corey A. Moffet; Kenneth E. Spaeth; Stuart P. Hardegree; Patrick E. Clark; C. Jason Williams

    2008-01-01

    Post-fire runoff and erosion from wildlands has been well researched, but few studies have researched the degree of control exerted by fire on rangeland hydrology and erosion processes. Furthermore, the spatial continuity and temporal persistence of wildfire impacts on rangeland hydrology and erosion are not well understood. Small-plot rainfall and concentrated flow...

  16. Relationships between energy release, fuel mass loss, and trace gas and aerosol emissions during laboratory biomass fires

    Treesearch

    Patrick H. Freeborn; Martin J. Wooster; Wei Min Hao; Cecily A. Nordgren Ryan; Stephen P. Baker; Charles Ichoku

    2008-01-01

    Forty-four small-scale experimental fires were conducted in a combustion chamber to examine the relationship between biomass consumption, smoke production, convective energy release, and middle infrared (MIR) measurements of fire radiative energy (FRE). Fuel bed weights, trace gas and aerosol particle concentrations, stack flow rate and temperature, and concurrent...

  17. Extinguishment and Burnback Testing of Fire Fighting Agents

    DTIC Science & Technology

    2005-09-26

    resisting burnback for hydrocarbon fuel fires. Potential Aqueous Film Forming Foam ( AFFF ) replacements are required to exhibit an...simple, reliable test to evaluate the effectiveness of new foams being introduced into the market as potential Aqueous Film Forming Foam ( AFFF ...normal concentrations. Reference: Military Specification MIL-F-24385F, Fire Extinguishing Agent, Aqueous Film - Forming Foam

  18. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  19. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  20. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  1. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  2. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  3. 46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  4. 46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  5. 46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  6. 46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  7. 46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  8. 46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  9. 46 CFR 193.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire detecting, manual alarm, and supervised patrol...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 193.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  10. 46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire detecting, manual alarm, and supervised patrol... AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Fire Detecting and Extinguishing Equipment, Where Required § 95.05-1 Fire detecting, manual alarm, and supervised patrol systems. (a) Fire detecting, manual...

  11. Dissolved black carbon in grassland streams: is there an effect of recent fire history?

    PubMed

    Ding, Yan; Yamashita, Youhei; Dodds, Walter K; Jaffé, Rudolf

    2013-03-01

    While the existence of black carbon as part of dissolved organic matter (DOM) has been confirmed, quantitative determinations of dissolved black carbon (DBC) in freshwater ecosystem and information on factors controlling its concentration are scarce. In this study, stream surface water samples from a series of watersheds subject to different burn frequencies in Konza Prairie (Kansas, USA) were collected in order to determine if recent fire history has a noticeable effect on DBC concentration. The DBC levels detected ranged from 0.04 to 0.11 mg L(-1), accounting for ca. 3.32±0.51% of dissolved organic carbon (DOC). No correlation was found between DBC concentration and neither fire frequency nor time since last burn. We suggest that limited DBC flux is related to high burning efficiency, possibly greater export during periods of high discharge and/or the continuous export of DBC over long time scales. A linear correlation between DOC and DBC concentrations was observed, suggesting the export mechanisms determining DOC and DBC concentrations are likely coupled. The potential influence of fire history was less than the influence of other factors controlling the DOC and DBC dynamics in this ecosystem. Assuming similar conditions and processes apply in grasslands elsewhere, extrapolation to a global scale would suggest a global grasslands flux of DBC on the order of 0.14 Mt carbon year(-1). Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. 46 CFR 108.403 - Fire extinguishing systems: General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire extinguishing systems: General. 108.403 Section 108.403 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403 Fire extinguishing systems: General. (a) Each...

  13. 46 CFR 108.403 - Fire extinguishing systems: General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire extinguishing systems: General. 108.403 Section 108.403 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403 Fire extinguishing systems: General. (a) Each...

  14. 46 CFR 108.403 - Fire extinguishing systems: General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire extinguishing systems: General. 108.403 Section 108.403 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403 Fire extinguishing systems: General. (a) Each...

  15. 46 CFR 108.403 - Fire extinguishing systems: General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire extinguishing systems: General. 108.403 Section 108.403 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403 Fire extinguishing systems: General. (a) Each...

  16. 46 CFR 108.403 - Fire extinguishing systems: General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire extinguishing systems: General. 108.403 Section 108.403 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403 Fire extinguishing systems: General. (a) Each...

  17. 14 CFR 25.1733 - Fire detector systems, general: EWIS.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire detector systems, general: EWIS. 25.1733 Section 25.1733 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Systems (EWIS) § 25.1733 Fire detector systems, general: EWIS. EWIS associated with any installed fire...

  18. 14 CFR 25.1733 - Fire detector systems, general: EWIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire detector systems, general: EWIS. 25.1733 Section 25.1733 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Systems (EWIS) § 25.1733 Fire detector systems, general: EWIS. EWIS associated with any installed fire...

  19. 14 CFR 25.1733 - Fire detector systems, general: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire detector systems, general: EWIS. 25.1733 Section 25.1733 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Systems (EWIS) § 25.1733 Fire detector systems, general: EWIS. EWIS associated with any installed fire...

  20. 14 CFR 25.1733 - Fire detector systems, general: EWIS.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire detector systems, general: EWIS. 25.1733 Section 25.1733 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Systems (EWIS) § 25.1733 Fire detector systems, general: EWIS. EWIS associated with any installed fire...

  1. 14 CFR 25.1733 - Fire detector systems, general: EWIS.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire detector systems, general: EWIS. 25.1733 Section 25.1733 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Systems (EWIS) § 25.1733 Fire detector systems, general: EWIS. EWIS associated with any installed fire...

  2. Are Invasive Species Stressful? The Glucocorticoid Profile of Native Lizards Exposed to Invasive Fire Ants Depends on the Context.

    PubMed

    Graham, Sean P; Freidenfelds, Nicole A; Thawley, Christopher J; Robbins, Travis R; Langkilde, Tracy

    Invasive species represent a substantial threat to native species worldwide. Research on the impacts of invasive species on wild living vertebrates has focused primarily on population-level effects. The sublethal, individual-level effects of invaders may be equally important but are poorly understood. We investigated the effects of invasive fire ants (Solenopsis invicta) on the physiological stress response of a native lizard (Sceloporus undulatus) within two experimental contexts: directly exposing lizards to a fire ant attack and housing lizards with fire ants in seminatural field enclosures. Lizards directly exposed to brief attack by fire ants had elevated concentrations of the stress hormone corticosterone (CORT), suggesting that these encounters can be physiologically stressful. However, lizards exposed for longer periods to fire ants in field enclosures had lower concentrations of CORT. This may indicate that the combined effects of confinement and fire ant exposure have pushed lizards into allostatic overload. However, lizards from fire ant enclosures appeared to have intact negative feedback controls of the stress response, evidenced by functioning adrenocorticotropic hormone responsiveness and lack of suppression of innate immunity (plasma bactericidal capacity). We review previous studies examining the stress response of wild vertebrates to various anthropogenic stressors and discuss how these-in combination with our results-underscore the importance of considering context (the length, frequency, magnitude, and types of threat) when assessing these impacts.

  3. Experimental Study of Fire Hazards of Thermal-Insulation Material in Diesel Locomotive: Aluminum-Polyurethane.

    PubMed

    Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong

    2016-03-05

    This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m² and 16.39 kW/m² for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m². The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation.

  4. Experimental Study of Fire Hazards of Thermal-Insulation Material in Diesel Locomotive: Aluminum-Polyurethane

    PubMed Central

    Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong

    2016-01-01

    This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m2 and 16.39 kW/m2 for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m2. The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation. PMID:28773295

  5. [Radio-ecological and hygienic assessment of consequences of forest fires in the areas polluted during the Chernobyl accident].

    PubMed

    Kashparov, V A; Lundin, S M; Kadygrib, A M; Protsak, V P; Levchuk, S E; Ioshchenko, V I; Kashpur, V A; Talerko, N N

    2001-01-01

    Retransfer of radionuclides on the condensation trails of Chernobyl radioactive fallouts during forest fires has been experimentally evaluated and their mathematical transfer model verified. It has been shown that radionuclide retransfer will make no great impact on additional pollution of an area even under the most unfavourable conditions. The contribution of convective and non-convective components of transfer to the formation of a radioactive aerosol concentration field has been assessed. Time course of changes in the concentration of radioactive aerosol and its dispersive composition are shown in different phases of fire and at different distance from its source.

  6. Introduction to fire danger rating and remote sensing - Will remote sensing enhance wildland fire danger prediction?

    USGS Publications Warehouse

    Allgöwer, Britta; Carlson, J.D.; Van Wagtendonk, Jan W.; Chuvieco, Emilio

    2003-01-01

    While ‘Fire Danger’ per se cannot be measured, the physical properties of the biotic and abiotic world that relate to fire occurrence and fire behavior can. Today, increasingly sophisticated Remote Sensing methods are being developed to more accurately detect fuel properties such as species composition (fuel types), vegetation structure or plant water content - to name a few. Based on meteorological input data and physical, semi-physical or empirical model calculations, Wildland Fire Danger Rating Systems provide ‘indirect values’ - numerical indices - at different temporal scales (e.g., daily, weekly, monthly) denoting the physical conditions that may lead to fire ignition and support fire propagation. The results can be expressed as fire danger levels, ranging from ‘low’ to ‘very high’, and are commonly used in operational wildland fire management (e.g., the Canadian Fire Weather Index [FWI] System, the Russian Nesterov Index, or the U.S. National Fire Danger Rating System [NFDRS]). Today, fire danger levels are often turned into broad scale maps with the help of Geographical Information Systems (GIS) showing the areas with the different fire danger levels, and are distributed via the World Wide Web.In this chapter we will outline some key issues dealing with Remote Sensing and GIS techniques that are covered in the following chapters, and elaborate how the Fire Danger Rating concepts could be integrated into a framework that enables comprehensive and sustainable wildland fire risk assessment. To do so, we will first raise some general thoughts about wildland fires and suggest how to approach this extremely complex phenomenon. Second, we will outline a possible fire risk analysis framework and third we will give a short overview on existing Fire Danger Rating Systems and the principles behind them.

  7. Fire danger and fire behavior modeling systems in Australia, Europe, and North America

    Treesearch

    Francis M. Fujioka; A. Malcolm Gill; Domingos X. Viegas; B. Mike Wotton

    2009-01-01

    Wildland fire occurrence and behavior are complex phenomena involving essentially fuel (vegetation), topography, and weather. Fire managers around the world use a variety of systems to track and predict fire danger and fire behavior, at spatial scales that span from local to global extents, and temporal scales ranging from minutes to seasons. The fire management...

  8. Reliable sex and strain discrimination in the mouse vomeronasal organ and accessory olfactory bulb.

    PubMed

    Tolokh, Illya I; Fu, Xiaoyan; Holy, Timothy E

    2013-08-21

    Animals modulate their courtship and territorial behaviors in response to olfactory cues produced by other animals. In rodents, detecting these cues is the primary role of the accessory olfactory system (AOS). We sought to systematically investigate the natural stimulus coding logic and robustness in neurons of the first two stages of accessory olfactory processing, the vomeronasal organ (VNO) and accessory olfactory bulb (AOB). We show that firing rate responses of just a few well-chosen mouse VNO or AOB neurons can be used to reliably encode both sex and strain of other mice from cues contained in urine. Additionally, we show that this population code can generalize to new concentrations of stimuli and appears to represent stimulus identity in terms of diverging paths in coding space. Together, the results indicate that firing rate code on the temporal order of seconds is sufficient for accurate classification of pheromonal patterns at different concentrations and may be used by AOS neural circuitry to discriminate among naturally occurring urine stimuli.

  9. Spatial distribution and risk assessment of radionuclides in soils around a coal-fired power plant: A case study from the city of Baoji, China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dai Lijun; Wei Haiyan; Wang Lingqing

    2007-06-15

    Coal burning may enhance human exposure to the natural radionuclides that occur around coal-fired power plants (CFPP). In this study, the spatial distribution and hazard assessment of radionuclides found in soils around a CFPP were investigated using statistics, geostatistics, and geographic information system (GIS) techniques. The concentrations of {sup 226}Ra, {sup 232}Th, and {sup 40}K in soils range from 12.54 to 40.18, 38.02 to 72.55, and 498.02 to 1126.98 Bq kg{sup -1}, respectively. Ordinary kriging was carried out to map the spatial patterns of radionuclides, and disjunctive kriging was used to quantify the probability of radium equivalent activity (Ra{sub eq})more » higher than the threshold. The maps show that the spatial variability of the natural radionuclide concentrations in soils was apparent. The results of this study could provide valuable information for risk assessment of environmental pollution and decision support.« less

  10. Spatial distribution and risk assessment of radionuclides in soils around a coal-fired power plant: A case study from the city of Baoji, China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dai, L.J.; Wei, H.Y.; Wang, L.Q.

    2007-06-15

    Coal burning may enhance human exposure to the natural radionuclides that occur around coal-fired power plants (CFPP). In this study, the spatial distribution and hazard assessment of radionuclides found in soils around a CFPP were investigated using statistics, geostatistics, and geographic information system (GIS) techniques. The concentrations of Ra-226, Th-232, and K-40 in soils range from 12.54 to 40.18, 38.02 to 72.55, and 498.02 to 1126.98 Bq kg{sup -1}, respectively. Ordinary kriging was carried out to map the spatial patterns of radionuclides, and disjunctive kriging was used to quantify the probability of radium equivalent activity (Ra{sub eq}) higher than themore » threshold. The maps show that the spatial variability of the natural radionuclide concentrations in soils was apparent. The results of this study could provide valuable information for risk assessment of environmental pollution and decision support.« less

  11. Spatial Investigation of Columnar AOD and Near-Surface PM2.5 Concentrations During the 2013 American and Yosemite Rim Fires

    NASA Astrophysics Data System (ADS)

    Loria Salazar, S. M.; Holmes, H.; Arnott, W. P.; Moosmuller, H.; Liming, A.; Echevarria, B.

    2014-12-01

    The study of aerosol pollution transport and optical properties in the western U.S. is a challenge due to the complex terrain, bright surfaces, presence of anthropogenic and biogenic emissions, secondary organic aerosol formation, and smoke from wild fires. In addition, the complex terrain influences transport phenomena by recirculating mountain air from California to Nevada, where air pollution from the Sierra Nevada Mountains (SNM) is mixed with urban air from the Central Valley in California. Previous studies in Reno hypothesize that elevated aerosol concentrations aloft, above the convective boundary layer height, make air quality monitoring in Reno challenging with MODIS products. Here, we analyze data from August 2013 as a case study for wildfire smoke plumes in California and Nevada. During this time period, northern California was impacted by large wild fires known as the American and Yosemite Rim fires. Thousands of acres burned, generating large quantities of aerosol pollutants that were transported downwind. The aim of the present work is to investigate the fire plume behavior and transport phenomena using ground level PM2.5 concentrations from routine monitoring networks and aerosol optical properties from AERONET, both at multiple locations in California and Nevada. In addition, the accuracy of MODIS (Collection 6) and VIIRS aerosol satellite products will be evaluated. The multispectral photoacoustic instruments and reciprocal nephelometers located in Reno support the estimation of approximated aerosol height. The objectives are to investigate the impact of the vertical distribution of PM concentrations on satellite aerosol optical depth (AOD) retrievals; assess the ability to estimate ground level PM2.5 mass concentrations for wildfire smoke plumes from satellite remote sensing; and investigate the influence of complex terrain on the transport of pollutants, convective boundary layer depth, and aerosol optical height.

  12. Measurements of nitrous oxide emissions from P.F. fired power stations

    NASA Astrophysics Data System (ADS)

    Sloan, S. A.; Laird, C. K.

    Nitrous oxide (N 2O) was measured in the flue gas from four wall-fired and three corner-fired 500 MW boilers, fitted with either conventional or low-NO x burners, at four C.E.G.B. power stations. Measurements were made both by on-line non-dispersive infra red (NDIR) monitors and by extractive sampling for later laboratory analysis by electron capture gas chromatography (ECD GC). It was found that the on-line and laboratory methods were in good agreement for samples analyzed within 1-3 h of sampling, but that the nitrous oxide concentration in the stored samples had a tendency to increase with time, which was dependent on the concentration of water in the sample. Experiments with synthetic mixtures showed that the increase in nitrous oxide concentration was consistent with the overall reaction2NO+SO 2→N 2O+SO 3 in which nitric oxide is reduced by sulphur dioxide. The highest average N 2O concentration measured by the on-line analyzer was 16 vpm, and for most of the boilers monitored the concentration was less than 10 vpm. There was no statistically significant difference between the measured N 2O emissions from normal boilers and those fitted with low-NO x burners. It is suggested that these values are close to the true levels of N 2O emissions from p.f. fired boilers and that recent reports of high levels (up to 200 vpm) are likely to be an artefact resulting from the observed generation of N 2O in stored samples. A consequence of these measurements of N 2O is that current estimates of the contribution of emissions from p.f. fired boilers to the global N 2O budget are likely to be too high.

  13. Polycyclic aromatic hydrocarbons in post-fire soils of drained peatlands in western Meshchera (Moscow region, Russia)

    NASA Astrophysics Data System (ADS)

    Tsibart, A.; Gennadiev, A.; Koshovskii, T.; Watts, A.

    2014-12-01

    Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants that arrive in the environment from numerous anthropogenic and natural sources, but the data on their natural sources including wildfires remain insufficient. The level of contamination and the composition of PAHs in soils of the areas affected by wildfires were studied in this work. The study was conducted in the Moscow region (Russia) in areas occupied by drained peatland and strongly damaged by fires in 2002, 2010 and 2012. The features of PAH accumulation and the profile distributions in histosols and histic podzols after the fires of different times were analyzed. It was shown that new soil horizons formed after the fires - Cpir, Hpir and incipient O horizons - and that these horizons differ in PAH accumulation rate. Maximal total concentrations of 14 PAHs were detected in charred peat horizons Hpir (up to 330 ng g-1) and in post-fire incipient O horizons (up to 180 ng g-1), but the high-molecular-weight PAHs (benz(ghi)perylene, benz(a)pyrene, benz(k)fluoranthene) were revealed only in charry peat horizons. The trends of higher PAH concentrations were found in cases when smoldering combustion resulted in rather thick residual peat horizons. In cases of almost complete pyrogenic destruction of He horizons, total PAH concentrations were no more than 50 ng g-1. Also, PAH accumulation in upper horizons of soils near the sites of the latest fires was observed.

  14. Quantity, composition and water contamination potential of ash produced under different wildfire severities.

    PubMed

    Santín, Cristina; Doerr, Stefan H; Otero, Xosé L; Chafer, Chris J

    2015-10-01

    Wildfires frequently threaten water quality through the transfer of eroded ash and soil into rivers and reservoirs. The ability to anticipate risks for water resources from wildfires is fundamental for implementing effective fire preparedness plans and post-fire mitigation measures. Here we present a new approach that allows quantifying the amount and characteristics of ash generated under different wildfire severities and its respective water contamination potential. This approach is applied to a wildfire in an Australian dry sclerophyll eucalypt forest, but can be adapted for use in other environments. The Balmoral fire of October 2013 affected 12,694 ha of Sydney's forested water supply catchment. It produced substantial ash loads that increased with fire severity, with 6, 16 and 34 Mg ha(-1) found in areas affected by low, high and extreme fire severity, respectively. Ash bulk density was also positively related to fire severity. The increase with fire severity in the total load and bulk density of the ash generated is mainly attributed to a combination of associated increases in (i) total amount of fuel affected by fire and (ii) contribution of charred mineral soil to the ash layer. Total concentrations of pollutants and nutrients in ash were mostly unrelated to fire severity and relatively low compared to values reported for wildfire ash in other environments (e.g. 4.0-7.3mg As kg(-1); 2.3-4.1 B mg kg(-1); 136-154 P mg kg(-1)). Solubility of the elements analysed was also low, less than 10% of the total concentration for all elements except for B (6-14%) and Na (30-50%). This could be related to a partial loss of soluble components by leaching and/or wind erosion before the ash sampling (10 weeks after the fire and before major ash mobilisation by water erosion). Even with their relatively low concentrations of potential pollutants, the substantial total ash loads found here represent a water contamination risk if transported into the hydrological network during severe erosion events. For example, up to 4 Mg of ash-derived P could be delivered into a single water supply reservoir. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    DTIC Science & Technology

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  16. Fire Safety Countermeasures for Urban Rail Vehicles

    DOT National Transportation Integrated Search

    1992-07-01

    The Volpe National Transportation Systems Center (VNTSC) has analyzed transit system fire statistics to learn how often fire and smoke incidents occur on rail transit systems. While the threat of fire accounts for only a small percentage of all rail ...

  17. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  18. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  19. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  20. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  1. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  2. 36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  3. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  4. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  5. 46 CFR 108.404 - Selection of fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Selection of fire detection system. 108.404 Section 108.404 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a...

  6. 46 CFR 108.413 - Fusible element fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fusible element fire detection system. 108.413 Section 108.413 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system...

  7. 46 CFR 108.413 - Fusible element fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fusible element fire detection system. 108.413 Section 108.413 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system...

  8. 46 CFR 108.404 - Selection of fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Selection of fire detection system. 108.404 Section 108.404 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a...

  9. 46 CFR 108.413 - Fusible element fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fusible element fire detection system. 108.413 Section 108.413 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system...

  10. 46 CFR 108.404 - Selection of fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Selection of fire detection system. 108.404 Section 108.404 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a...

  11. 46 CFR 108.404 - Selection of fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Selection of fire detection system. 108.404 Section 108.404 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a...

  12. 46 CFR 108.413 - Fusible element fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fusible element fire detection system. 108.413 Section 108.413 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system...

  13. 75 FR 8431 - Carbon Dioxide Fire Suppression Systems on Commercial Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ... Fire Suppression Systems on Commercial Vessels; Proposed Rule #0;#0;Federal Register / Vol. 75 , No. 36... 1625-AB44 Carbon Dioxide Fire Suppression Systems on Commercial Vessels AGENCY: Coast Guard, DHS... for fire suppression systems on several classes of commercial vessels. The amendments would clarify...

  14. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  15. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  16. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  17. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  18. Fire and Emission Characterization in the Northern Sub-Saharan Africa (NSSA) Region and their Potential Effects on the Regional Climate System

    NASA Astrophysics Data System (ADS)

    Ellison, L.; Ichoku, C. M.

    2013-12-01

    Northern Sub-Saharan Africa (NSSA) is known for its consistent vast amounts of seasonal biomass burning each year. These mostly anthropogenic slash-and-burn fires typically used for farming and grazing purposes contributes to a significant proportion of the total global emissions of particulate matter (PM). The consequences of such severe burning could potentially have a noticeable influence on local climate patterns, such as the frequent severe droughts over the past century or the drying of Lake Chad, through both direct and indirect causes. This research therefore focuses on: 1) characterizing the burning patterns and extent within NSSA, 2) accurately quantifying PM emissions that have a direct impact on climate, and 3) exploring potential indirect impacts of burning on climate through evaluation of correlations with various environmental and meteorological parameters. In this study, the NSSA region was first split into nine distinct sub-regions to better analyze the burning patters and climatological changes. The diurnal cycle of fire radiative power (FRP, a quantifiable way of measuring fire radiant heat output) within these different regions differ in amplitude and shape, though the basic shape is the same with months of maximum FRP being between November and January and with practically no fires during the rainy season. Corresponding changes in other climatological variables were studied against changes seen in FRP on a monthly scale, including precipitation, soil moisture, surface evaporation, evapotranspiration (ET), normalized difference vegetation index (NDVI) and aerosol optical depth (AOD). This study includes an analysis of the distinct change in FRP signal that occurred in 2006 for the middle of the NSSA region, which is the area with the highest concentration of fires. A decrease in maximum monthly FRP has been observed since 2006 in this region. Regional changes in PM emissions have also been observed since then, including a large region of decreasing emissions southwest of Lake Chad. These emissions are taken from the new Fire Energetics and Emissions Research (FEER) emissions product that was developed as part of this NSSA research and is based on a global coefficient of emission (Ce) map with high spatial resolution. The FEER algorithm is a top-down approach in an effort to properly account for all emitted PM, which is especially important in the NSSA region because of its high concentration of fire events. When the FEER Ce v1.0 product is combined with the global FRP dataset from the Global Fire Assimilation System (GFAS) v1.0 product to generate PM emissions, estimates of total particulate matter (TPM) are generated. The FEER product estimates average annual TPM emissions in the NSSA region to be around 14 Tg between 2004-2010, which is greater than GFAS v1.0 by a factor of 1.8, and greater than the Global Fire Emissions Database (GFED) v3.1 by a factor of 1.6. Future work will plug these new emission estimates into regional models to gain a better understanding of the impacts of biomass burning on climate in NSSA.

  19. Fire Detection Organizing Questions

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Verified models of fire precursor transport in low and partial gravity: a. Development of models for large-scale transport in reduced gravity. b. Validated CFD simulations of transport of fire precursors. c. Evaluation of the effect of scale on transport and reduced gravity fires. Advanced fire detection system for gaseous and particulate pre-fire and fire signaturesa: a. Quantification of pre-fire pyrolysis products in microgravity. b. Suite of gas and particulate sensors. c. Reduced gravity evaluation of candidate detector technologies. d. Reduced gravity verification of advanced fire detection system. e. Validated database of fire and pre-fire signatures in low and partial gravity.

  20. Numerical study of propagation of forest fires in the presence of fire breaks using an averaged setting

    NASA Astrophysics Data System (ADS)

    Marzaeva, S. I.; Galtseva, O. V.

    2018-05-01

    The forest fires spread in the pine forests have been numerically simulated using a three-dimensional mathematical model. The model was integrated with respect to the vertical coordinate because horizontal sizes of forest are much greater than the heights of trees. In this paper, the assignment and theoretical investigations of the problems of crown forest fires spread pass the firebreaks were carried out. In this context, a study ( mathematical modeling) of the conditions of forest fire spreading that would make it possible to obtain a detailed picture of the change in the temperature and component concentration fields with time, and determine as well as the limiting condition of fire propagation in forest with these fire breaks.

  1. Estimation of fire emissions from satellite-based measurements

    NASA Astrophysics Data System (ADS)

    Ichoku, C. M.; Kaufman, Y. J.

    2004-12-01

    Biomass burning is a worldwide phenomenon affecting many vegetated parts of the globe regularly. Fires emit large quantities of aerosol and trace gases into the atmosphere, thus influencing the atmospheric chemistry and climate. Traditional methods of fire emissions estimation achieved only limited success, because they were based on peripheral information such as rainfall patterns, vegetation types and changes, agricultural practices, and surface ozone concentrations. During the last several years, rapid developments in satellite remote sensing has allowed more direct estimation of smoke emissions using remotely-sensed fire data. However, current methods use fire pixel counts or burned areas, thereby depending on the accuracy of independent estimations of the biomass fuel loadings, combustion efficiency, and emission factors. With the enhanced radiometric range of its 4-micron fire channel, the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor, which flies aboard both of the Earth Observing System (EOS) Terra and Aqua Satellites, is able to measure the rate of release of fire radiative energy (FRE) in MJ/s (something that older sensors could not do). MODIS also measures aerosol distribution. Taking advantage of these new resources, we have developed a procedure combining MODIS fire and aerosol products to derive FRE-based smoke emission coefficients (Ce in kg/MJ) for different regions of the globe. These coefficients are simply used to multiply FRE from MODIS to derive the emitted smoke aerosol mass. Results from this novel methodology are very encouraging. For instance, it was found that the smoke total particulate mass emission coefficient for the Brazilian Cerrado ecosystem (approximately 0.022 kg/MJ) is about twice the value for North America or Australia, but about 50 percent lower than the value for Zambia in southern Africa.

  2. Quantifying Wildfire Emissions and associated Aerosol Species using Assimilation of Satellite Carbon Monoxide Retrievals

    NASA Astrophysics Data System (ADS)

    Edwards, David; Barre, Jerome; Worden, Helen; Gaubert, Benjamin

    2017-04-01

    Intense and costly wildfires tend are predicted to increase in frequency under a warming climate. For example, the recent August 2015 Washington State fires were the largest in the state's history. Also in September and October 2015 very intense fires over Indonesia produced some of the highest concentrations of carbon monoxide (CO) ever seen from satellite. Such larges fires impact not only the local environment but also affect air quality far downwind through the long-range transport of pollutants. Global to continental scale coverage showing the evolution of CO resulting from fire emission is available from satellite observations. Carbon monoxide is the only atmospheric trace gas for which satellite multispectral retrievals have demonstrated reliable independent profile information close to the surface and also higher in the free troposphere. The unique CO profile product from Terra/MOPITT clearly distinguishes near-surface CO from the free troposphere CO. Also previous studies have suggested strong correlations between primary emissions of fire organic and black carbon aerosols and CO. We will present results from the Ensemble Adjustement Kalman Filter (DART) system that has been developed to assimilate MOPITT CO in the global-scale chemistry-climate model CAM-Chem. The ensemble technique allows inference on various fire model state variables such as CO emissions, and also aerosol species resulting from fires such as organic and black carbon. The benefit of MOPITT CO profile assimilation for estimating the CO emissions from the Washington and Indonesian fire cases will be discussed, along with the ability of the ensemble approach to infer information on the black and organic carbon aerosol distribution. This study builds on capability to quantitatively integrate satellite observations and models developed in recent years through projects funded by the NASA ACMAP Program.

  3. Estimation of Fire Emissions from Satellite-Based Measurements

    NASA Technical Reports Server (NTRS)

    Ichoku, Charles; Kaufman, Yoram J.

    2004-01-01

    Biomass burning is a worldwide phenomenon affecting many vegetated parts of the globe regularly. Fires emit large quantities of aerosol and trace gases into the atmosphere, thus influencing the atmospheric chemistry and climate. Traditional methods of fire emissions estimation achieved only limited success, because they were based on peripheral information such as rainfall patterns, vegetation types and changes, agricultural practices, and surface ozone concentrations. During the last several years, rapid developments in satellite remote sensing has allowed more direct estimation of smoke emissions using remotely-sensed fire data. However, current methods use fire pixel counts or burned areas, thereby depending on the accuracy of independent estimations of the biomass fuel loadings, combustion efficiency, and emission factors. With the enhanced radiometric range of its 4-micron fire channel, the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor, which flies aboard both of the Earth Observing System EOS) Terra and Aqua Satellites, is able to measure the rate of release of fire radiative energy (FRE) in MJ/s (something that older sensors could not do). MODIS also measures aerosol distribution. Taking advantage of these new resources, we have developed a procedure combining MODIS fire and aerosol products to derive FRE-based smoke emission coefficients (C(e), in kg/MJ) for different regions of the globe. These coefficients are simply used to multiply FRE from MODIS to derive the emitted smoke aerosol mass. Results from this novel methodology are very encouraging. For instance, it was found that the smoke total particulate mass emission coefficient for the Brazilian Cerrado ecosystem (approximately 0.022 kg/MJ) is about twice the value for North America, Western Europe, or Australia, but about 50% lower than the value for southern Africa.

  4. The Fire Effects Information System

    Treesearch

    William C. Fischer

    1987-01-01

    Lack of information regarding fire effects is perceived by many fire and resource managers as a barrier to the effective application of prescribed fire. This lack of information, in many instances, is the result of poor diffusion of existing knowledge rather than lack of knowledge. A computerized Fire Effects Information System can make existing fire effects knowledge...

  5. The Wildland Fire Decision Support System: Integrating science, technology, and fire management

    Treesearch

    Morgan Pence; Tom Zimmerman

    2011-01-01

    Federal agency policy requires documentation and analysis of all wildland fire response decisions. In the past, planning and decision documentation for fires were completed using multiple unconnected processes, yielding many limitations. In response, interagency fire management executives chartered the development of the Wildland Fire Decision Support System (WFDSS)....

  6. 46 CFR 108.425 - Fire hoses and associated equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... either: (1) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2... 46 Shipping 4 2012-10-01 2012-10-01 false Fire hoses and associated equipment. 108.425 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.425 Fire hoses and associated...

  7. 46 CFR 108.425 - Fire hoses and associated equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... either: (1) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2... 46 Shipping 4 2014-10-01 2014-10-01 false Fire hoses and associated equipment. 108.425 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.425 Fire hoses and associated...

  8. 46 CFR 108.425 - Fire hoses and associated equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... either: (1) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2... 46 Shipping 4 2013-10-01 2013-10-01 false Fire hoses and associated equipment. 108.425 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.425 Fire hoses and associated...

  9. FIRE ALARM SYSTEM OUTDATED.

    ERIC Educational Resources Information Center

    CHANDLER, L.T.

    AN EFFICIENT FIRE ALARM SYSTEM SHOULD--(1) PROVIDE WARNING OF FIRES THAT START IN HIDDEN OR UNOCCUPIED LOCATIONS, (2) INDICATE WHERE THE FIRE IS, (3) GIVE ADVANCE WARNING TO FACULTY AND ADMINISTRATION SO THAT PANIC AND CONFUSION CAN BE AVOIDED AND ORDERLY EVACUATION OCCUR, (4) AUTOMATICALLY NOTIFY CITY FIRE HEADQUARTERS OF THE FIRE, (5) OPERATE BY…

  10. Broadband spectroscopic sensor for real-time monitoring of industrial SO(2) emissions.

    PubMed

    Xu, Feng; Zhang, Yungang; Somesfalean, Gabriel; Wang, Huashan; Wu, Shaohua; Zhang, Zhiguo

    2007-05-01

    A spectroscopic system for continuous real-time monitoring of SO(2) concentrations in industrial emissions was developed. The sensor is well suited for field applications due to simple and compact instrumental design, and robust data evaluation based on ultraviolet broadband absorption without the use of any calibration cell. The sensor has a detection limit of 1 ppm, and was employed both for gas-flow simulations with and without suspended particles, and for in situ measurement of SO(2) concentrations in the flue gas emitted from an industrial coal-fired boiler. The price/performance ratio of the instrument is expected to be superior to other comparable real-time monitoring systems.

  11. Evaluation of the CNS and cardiovascular effects of prolonged exposure to bromotrifluromethane (CBrF3)

    NASA Technical Reports Server (NTRS)

    Geller, I.; Garcia, C.; Gleiser, C.; Haines, R., Jr.; Hamilton, M.; Hartmann, R., Jr.; Mendez, V.; Samuels, A.; Miguel, M. S.

    1981-01-01

    The proposed use of bromotrifluoromethane (CBrF3) as a fire extinguishant in aircraft, spacecraft and submarines has stimulated increasing interest and research in the toxicological properties of this compound. In a spacecraft, because of its unique recirculating life support system, the introduction of CBrF3 by leakage or intentional discharge, will result in continuous exposure of crewman to low concentrations of this compound for periods of up to 7 days, or possibly even longer. The effects of low concentrations of CBrF3, under continuous exposure conditions, on the CNS and cardiovascular systems of animals to enable an assessment of these risks were investigated.

  12. Cloud Condensation Nuclei in Fire-3

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The centerpiece of this research was the cloud condensation nuclei (CCN) measurements of the Desert Research Institute (DRI) CCN spectrometers on board the NCAR C-130 aircraft during the Arctic Cloud Experiment (ACE) in May, 1998. These instruments operated successfully throughout all eight 10-hour research flights based in Fairbanks and the two ferry flights between Colorado and Fairbanks. Within a few months of completion of ACE the CCN data was edited and put into the archives. A paper was completed and published on the CCN climatology during the previous two FIRE field projects-FIRE 1 based in San Diego in June and July, 1987 and ASTEX based in the Azores Islands in June, 1992. This showed distinct contrasts in concentrations and spectra between continental and maritime CCN concentrations, which depended on air mass trajectories. Pollution episodes from Europe had distinct influences on particle concentrations at low altitudes especially within the boundary layer. At higher altitudes concentrations were similar in the two air mass regimes. Cloudier atmospheres showed lower concentrations especially below the clouds, which were a result mostly of coalescence scavenging.

  13. Importance of transboundary transport of biomass burning emissions to regional air quality in Southeast Asia

    NASA Astrophysics Data System (ADS)

    Aouizerats, B.; van der Werf, G. R.; Balasubramanian, R.; Betha, R.

    2014-05-01

    Smoke from biomass and peat burning has a notable impact on ambient air quality and climate in the Southeast Asia (SEA) region. We modeled the largest fire-induced haze episode in the past decade (2006) in Indonesia using the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem). We focused mainly on the evolution of the fire plume composition and its interaction with the urbanized area of the city-state of Singapore, and on comparisons of modeled and measured aerosol and CO concentrations. Two simulations were run with the model using the complex Volatility Basis Set (VBS) scheme to reproduce primary and secondary aerosol evolution and concentration. The first simulation referred to as WRF-FIRE included anthropogenic, biogenic, and b iomass burning emissions from the Global Fire Emissions Database (GFED3) while the second simulation referred to as WRF-NOFIRE was run without emissions from biomass burning. To test model performance, we used three independent datasets for comparison including airborne measurements of Particulate Matter with a diameter of 10 μm or less (PM10) in Singapore, CO measurements in Sumatra, and Aerosol Optical Depth (AOD) column observations from 4 satellite-based sensors. We found reasonable agreement of the model runs with both ground-based measurements of CO and PM10. The comparison with AOD was less favorable and indicated the model underestimated AOD, although the degree of mismatch varied between different satellite data sets. During our study period, forest and peat fires in Sumatra were the main cause of enhanced aerosol concentrations from regional transport over Singapore. Analysis of the biomass burning plume showed high concentrations of primary organic aerosols (POA) with values up to 600 μg m-3 over the fire locations. The concentration of POA remained quite stable within the plume between the main burning region and Singapore while secondary organic aerosol (SOA) concentration slightly increased. The absolute values of SOA (up to 20 μg m-3) were much lower than those from POA, indicating a minor role of SOA in biomass burning plumes. Our results show that about 21% of the total mass loading of ambient PM10 during the July-October study period in Singapore was due to biomass and peat burning in Sumatra, but this contribution increased during high burning periods. In total, our model results indicated that during 35 days aerosol concentrations in Singapore were above the threshold of 50 μg m-3 day-1 indicating poor air quality. During 17 days this was due to fires, based on the difference between the simulations with and without fires. Local pollution in combination with recirculation of air masses was probably the main cause of poor air quality during the other 18 days, although fires from Sumatra and probably also from Borneo added to the enhanced PM10 concentrations. The model vs. measurement comparisons highlighted that for our study period and region the GFED3 biomass burning aerosol emissions were more in line with observations than found in other studies. This indicates that care should be taken when using AOD to constrain emissions or estimate ground-level air quality. This study also shows the need for relatively high resolution modeling to accurately reproduce the advection of air masses necessary to quantify the impacts and feedbacks on air quality.

  14. Short term effects of fire on soil respiration in Peruvian Amazon

    NASA Astrophysics Data System (ADS)

    Suarez, L. F.; Kruijt, B.

    2008-05-01

    Severe changes are affecting the role of Amazon in the Earth system. One of these possible effects could be the modification of the role of soils in the carbon cycle due to land use and land cover change activities mainly involving the change of forest by crops. In this sense, fire is the main tool used by farmers for land use and also is an important factor for mobilizing C from the soil to the atmosphere, mainly as CO2. This could have an important effect in the global warming. This proposal will evaluate the variation of the soil respiration related to the seasonality and the fire effects on soils in the Amazon of Peru and Brazil. In experimental locations of Peru with different vegetation cover (forest and pasture), we measured soil respiration along with the organic carbon and the microbial biomass of soils during campaigns covering wet and dry seasons. Complementary measurements of soil temperature, water and nutrient content were performed. Also, we reproduced a fire experiment simulating agricultural local activity by the technique of "slash and burn" to evaluate fire effects on soil respiration. Measurements were taken after the soil cooled and at least 3 days after the fire. Additionally, the carbon stocks of the subplots were evaluated. Evaluation of the variations of CO2 fluxes and the capacity of adaptation to fire and water content are discussed through the comparisons of the different locations, type of soils and concentration of available N (nitrate and ammonium) as an indicator of nutrient content.

  15. Small, modular, low-cost coal-fired power plants for the international market

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zauderer, B.; Frain, B.; Borck, B.

    1997-12-31

    This paper presents recent operating results of Coal Tech`s second generation, air cooled, slagging coal combustor, and its application to power plants in the 1 to 20 MW range. This 20 MMBtu/hour combustor was installed in a new demonstration plant in Philadelphia, PA in 1995. It contains the combustion components of a 1 MWe coal fired power plant, a 17,500 lb/hour steam boiler, coal storage and feed components, and stack gas cleanup components. The plant`s design incorporates improvements resulting from 2,000 hours of testing between 1987 and 1993 on a first generation, commercial scale, air cooled combustor of equal thermalmore » rating. Since operations began in early 1996, a total of 51 days of testing have been successfully completed. Major results include durability of the combustor`s refractory wall, excellent combustion with high ash concentration in the fuel, removal of 95% to 100% of the slag in the combustor, very little ash deposition in the boiler, major reduction of in-plant parasitic power, and simplified power system control through the use of modular designs of sub-systems and computer control. Rapid fuel switching between oil, gas, and coal and turndown of up to a factor of three was accomplished. All these features have been incorporated in advanced coal fired plant designs in the 1 to 20 MWe range. Incremental capital costs are only $100 to $200/kW higher than comparable rated gas or oil fired steam generating systems. Most of its components and subsystems can be factory assembled for very rapid field installation. The low capital, low operating costs, fuel flexibility, and compatibility with very high ash fuels, make this power system very attractive in regions of the world having domestic supplies of these fuels.« less

  16. Environmental assessment of a wood-waste-fired industrial firetube boiler. Volume 2. Data supplement. Final report, January 1981-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.; Waterland, L.R.

    1987-03-01

    The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue-gas emissions; source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue-gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace-element-content determinations. Emission levels of five polycyclic organicmore » matter species and phenol were quantitated: except for naphthalene, all were emitted at less than 0.4 microgram/dscm.« less

  17. Cloud Condensation Nuclei in FIRE III

    NASA Technical Reports Server (NTRS)

    Hudson, James G.; Delnore, Victor E. (Technical Monitor)

    2002-01-01

    Yum and Hudson showed that the springtime Arctic aerosol is probably a result of long-range transport at high altitudes. Scavenging of particles by clouds reduces the low level concentrations by a factor of 3. This produces a vertical gradient in particle concentrations when low-level clouds are present. Concentrations are uniform with height when clouds are not present. Low-level CCN (cloud condensation nuclei) spectra are similar to those in other maritime areas as found by previous projects including FIRE 1 and ASTEX, which were also supported on earlier NASA-FIRE grants. Wylie and Hudson carried this work much further by comparing the CCN spectra observed during ACE with back trajectories of air masses and satellite photographs. This showed that cloud scavenging reduces CCN concentrations at all altitudes over the springtime Arctic, with liquid clouds being more efficient scavengers than frozen clouds. The small size of the Arctic Ocean seems to make it more susceptible to continental and thus anthropogenic aerosol influences than any of the other larger oceans.

  18. School Fire Protection: Contents Count

    ERIC Educational Resources Information Center

    American School and University, 1976

    1976-01-01

    The heart of a fire protection system is the sprinkler system. National Fire Protection Association (NFPA) statistics show that automatic sprinklers dramatically reduce fire damage and loss of life. (Author)

  19. Developing custom fire behavior fuel models from ecologically complex fuel structures for upper Atlantic Coastal Plain forests

    Treesearch

    Bernard R. Parresol; Joe H. Scott; Anne Andreu; Susan Prichard; Laurie Kurth

    2012-01-01

    Currently geospatial fire behavior analyses are performed with an array of fire behavior modeling systems such as FARSITE, FlamMap, and the Large Fire Simulation System. These systems currently require standard or customized surface fire behavior fuel models as inputs that are often assigned through remote sensing information. The ability to handle hundreds or...

  20. Mitigating operating room fires: development of a carbon dioxide fire prevention device.

    PubMed

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-04-01

    Operating room fires are sentinel events that present a real danger to surgical patients and occur at least as frequently as wrong-sided surgery. For fire to occur, the 3 points of the fire triad must be present: an oxidizer, an ignition source, and fuel source. The electrosurgical unit (ESU) pencil triggers most operating room fires. Carbon dioxide (CO2) is a gas that prevents ignition and suppresses fire by displacing oxygen. We hypothesize that a device can be created to reduce operating room fires by generating a cone of CO2 around the ESU pencil tip. One such device was created by fabricating a divergent nozzle and connecting it to a CO2 source. This device was then placed over the ESU pencil, allowing the tip to be encased in a cone of CO2 gas. The device was then tested in 21%, 50%, and 100% oxygen environments. The ESU was activated at 50 W cut mode while placing the ESU pencil tip on a laparotomy sponge resting on an aluminum test plate for up to 30 seconds or until the sponge ignited. High-speed videography was used to identify time of ignition. Each test was performed in each oxygen environment 5 times with the device activated (CO2 flow 8 L/min) and with the device deactivated (no CO2 flow-control). In addition, 3-dimensional spatial mapping of CO2 concentrations was performed with a CO2 sampling device. The median ± SD [range] ignition time of the control group in 21% oxygen was 2.9 s ± 0.44 [2.3-3.0], in 50% oxygen 0.58 s ± 0.12 [0.47-0.73], and in 100% oxygen 0.48 s ± 0.50 [0.03-1.27]. Fires were ignited with each control trial (15/15); no fires ignited when the device was used (0/15, P < 0.0001). The CO2 concentration at the end of the ESU pencil tip was 95%, while the average CO2 concentration 1 to 1.4 cm away from the pencil tip on the bottom plane was 64%. In conclusion, an operating room fire prevention device can be created by using a divergent nozzle design through which CO2 passes, creating a cone of fire suppressant. This device as demonstrated in a flammability model effectively reduced the risk of fire. CO2 3-dimensional spatial mapping suggests effective fire reduction at least 1 cm away from the tip of the ESU pencil at 8 L/min CO2 flow. Future testing should determine optimum CO2 flow rates and ideal nozzle shapes. Use of this device may substantially reduce the risk of patient injury due to operating room fires.

  1. Testing Method for External Cladding Systems - Incerc Romania

    NASA Astrophysics Data System (ADS)

    Simion, A.; Dragne, H.

    2017-06-01

    This research presents a new testing method in a natural scale for external cladding systems tested on buildings with minimum than 3 floors [1]. The testing method is unique in Romania and it is similar about many fire testing current methods from European Union states. Also, presents the fire propagation and the effect of fire smoke on the building façade composed of thermal insulation. Laboratory of testing and research for building fire safety from National Institute INCERC Bucharest, provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems and external wall insulation systems when applied to the face of a building and exposed to an external fire under controlled conditions [2]. The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or an external fire source. On the future, fire tests will be experimented for answer demande a number of high-profile fires where the external facade of tall buildings provided a route for vertical fire spread.

  2. Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review.

    PubMed

    Fonollosa, Jordi; Solórzano, Ana; Marco, Santiago

    2018-02-11

    Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative.

  3. Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review

    PubMed Central

    Fonollosa, Jordi

    2018-01-01

    Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative. PMID:29439490

  4. 46 CFR 76.50-10 - Location.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  5. 46 CFR 76.50-10 - Location.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  6. 14 CFR 23.1201 - Fire extinguishing systems materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire extinguishing systems materials. 23.1201 Section 23.1201 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Powerplant Powerplant Fire Protection § 23.1201 Fire extinguishing systems materials. For commuter category...

  7. Studies of emotional instability in smoke from fires: Decrease of thinking powers and of memory in fire smoke

    NASA Astrophysics Data System (ADS)

    Jin, T.

    The effect and degree of smoke concentration on the reduction in thinking and memory was studied. The change in memory and thinking power was estimated by the change in correction ratio for mental calculation in various smoke concentrations. The reduction of memory in a smokey environment estimated by the correction ratio for remembering the order of four color panels which were shown before smoke exposure. It is found that it is difficult to evaluate the relationship between the reduction in thinking power against smoke concentration, and relationship between the reductions of memory against smoke concentration.

  8. Characterization of Atmospheric Emission Produced by Live Gun Firing: Test on the M777 155 mm Howitzer

    DTIC Science & Technology

    2007-10-01

    dispersion of residues at firing points during 105 mm howitzer live firing exercises. Residues of nitrocellulose fibres collected in front of the...Les résidus de fibres de nitrocellulose prélevés devant la bouche du canon ont montré des concentrations non négligeables en 2,4...nitrocellulose fibres deposited in front and around the gun muzzle after artillery or tank firing exercises ([7]). In 2003, DRDC Valcartier began to

  9. 46 CFR 108.403a - Fire extinguishing systems: Non-vital services.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire extinguishing systems: Non-vital services. 108.403a Section 108.403a Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403a Fire extinguishing systems: Non...

  10. 46 CFR 108.403a - Fire extinguishing systems: Non-vital services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire extinguishing systems: Non-vital services. 108.403a Section 108.403a Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403a Fire extinguishing systems: Non...

  11. 46 CFR 108.403a - Fire extinguishing systems: Non-vital services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire extinguishing systems: Non-vital services. 108.403a Section 108.403a Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403a Fire extinguishing systems: Non...

  12. 46 CFR 108.403a - Fire extinguishing systems: Non-vital services.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire extinguishing systems: Non-vital services. 108.403a Section 108.403a Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403a Fire extinguishing systems: Non...

  13. 46 CFR 108.403a - Fire extinguishing systems: Non-vital services.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire extinguishing systems: Non-vital services. 108.403a Section 108.403a Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.403a Fire extinguishing systems: Non...

  14. 46 CFR 132.310 - Fixed fire-extinguishing systems for paint lockers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fixed fire-extinguishing systems for paint lockers. 132... lockers. (a) Except as provided by paragraph (b) of this section, a fixed gaseous fire-extinguishing system or another approved fixed fire-extinguishing system must be installed in each paint locker. (b) No...

  15. 46 CFR 132.310 - Fixed fire-extinguishing systems for paint lockers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fixed fire-extinguishing systems for paint lockers. 132... lockers. (a) Except as provided by paragraph (b) of this section, a fixed gaseous fire-extinguishing system or another approved fixed fire-extinguishing system must be installed in each paint locker. (b) No...

  16. 46 CFR 132.310 - Fixed fire-extinguishing systems for paint lockers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fixed fire-extinguishing systems for paint lockers. 132... lockers. (a) Except as provided by paragraph (b) of this section, a fixed gaseous fire-extinguishing system or another approved fixed fire-extinguishing system must be installed in each paint locker. (b) No...

  17. 46 CFR 132.310 - Fixed fire-extinguishing systems for paint lockers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fixed fire-extinguishing systems for paint lockers. 132... lockers. (a) Except as provided by paragraph (b) of this section, a fixed gaseous fire-extinguishing system or another approved fixed fire-extinguishing system must be installed in each paint locker. (b) No...

  18. 46 CFR 132.310 - Fixed fire-extinguishing systems for paint lockers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fixed fire-extinguishing systems for paint lockers. 132... lockers. (a) Except as provided by paragraph (b) of this section, a fixed gaseous fire-extinguishing system or another approved fixed fire-extinguishing system must be installed in each paint locker. (b) No...

  19. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  20. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  1. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  2. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  3. Global Distribution of Pyrogenic Carbon

    NASA Astrophysics Data System (ADS)

    Reisser, Moritz; Abiven, Samuel; Schmidt, Michael W. I.

    2016-04-01

    Pyrogenic Carbon (PyC) is ubiquitous in the environment and represents presumably one of the most stable compounds of the total organic carbon. Due to its persistence in the soil, it might play an important role in the global carbon cycle. In order to model future CO2 emissions from soils it is thus crucial to know where and how much of PyC exists on a global scale. Yet, only rough estimates for global PyC stocks in soils could be made, and even less is known about the distribution across ecosystems. Therefore we propose here literature analysis of data on PyC concentrations and stocks worldwide. We extracted PyC values in soils from the literature (n = 600) and analysed the percentage of PyC in the soil organic carbon (SOC) as a function of climate (temperature, precipitation), soil parameters (pH, clay content), fire characteristics (fire frequency and fire regime) and land use. Overall, the average contribution of PyC to SOC was 13 %, ranging from 0.1 % up to 60 %. We observed that the PyC content was significantly higher with high clay content, higher pH, and in cultivated land as compared to forest and grassland. We did not observe any relationships between fire activity, frequency or intensity and PyC % at a global scale. When the fire regime was monitored on site (only 12 % of the data we collected), we observed higher PyC concentrations with higher fire frequencies. We hypothesise that the resolution of global fire datasets is neither temporally nor spatially high enough to explain the very local fire history of the soil samples. Data points were not homogeneously distributed on the globe, but rather aggregated in places like Central Europe, the Russian Steppe or North America. Therefore, a global interpolation is not directly possible. We modelled PyC concentrations, based on the five most significant parameters, which were clay content, pH, mean annual temperature and precipitation as well as land use. We then predicted worldwide PyC using global datasets existing for these five variables. We present a global map of PyC concentrations as well as it stocks. In arid ecosystems, where SOC is generally low, stocks of PyC are also low, even though concentrations can be very high. On the other hand, stocks are mostly very large in temperate and boreal ecosystems, even if concentrations are rather low, because total SOC stocks are very high there. Integrating our modelled data, we result in a total global stock of about 230 Pg PyC, corresponding to about 10 % of the total soil organic carbon stock. This value lies well in range with current rule-of-thump estimates of previous studies.

  4. Smokey comes of age: Unmanned aerial systems for fire management

    USGS Publications Warehouse

    Twidwell, Dirac; Allen, Craig R.; Detweiler, Carrick; Higgins, James; Laney, Christian; Elbaum, Sebastian

    2016-01-01

    During the past century, fire management has focused on techniques both to protect human communities from catastrophic wildfire and to maintain fire-dependent ecological systems. However, despite a large and increasing allocation of resources and personnel to achieve these goals, fire management objectives at regional to global scales are not being met. Current fire management techniques are clearly inadequate for the challenges faced by fire managers, and technological innovations are needed. Advances in unmanned aerial systems (UAS) technology provide opportunities for innovation in fire management and science. In many countries, fire management organizations are beginning to explore the potential of UAS for monitoring fires. We have taken the next step and developed a prototype that can precisely ignite fires as part of wildfire suppression tactics or prescribed fires (fire intentionally ignited within predetermined conditions to reduce hazardous fuels, improve habitat, or mitigate for large wildfires). We discuss the potential for these technologies to benefit fire management activities, while acknowledging the sizeable sociopolitical barriers that prevent their immediate broad application.

  5. Forest Fire Mapping

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The Fire Logistics Airborne Mapping Equipment (FLAME) system, mounted in a twin-engine and airplane operated by the U.S. Forest Service (USFS) of the U.S. Department of Agriculture (USDA), is an airborne instrument for detecting and pinpointing forest fires that might escape ground detection. The FLAME equipment rack includes the operator interface, a video monitor, the system's control panel and film output. FLAME's fire detection sensor is an infrared line scanner system that identifies fire boundaries. Sensor's information is correlated with the aircraft's position and altitude at the time the infrared imagery is acquired to fix the fire's location on a map. System can be sent to a fire locale anywhere in the U.S. at the request of a regional forester. USFS felt a need for a more advanced system to deliver timely fire information to fire management personnel in the decade of the 1990s. The Jet Propulsion Laboratory (JPL) conducted a study, jointly sponsored by NASA and USDA, on what advanced technologies might be employed to produce an end-to-end thermal infrared fire detection and mapping system. That led to initiation of the Firefly system, currently in development at JPL and targeted for operational service beginning in 1992. Firefly will employ satellite-reference position fixing and provide performance superior to FLAME.

  6. Selected Parametric Effects on Materials Flammability Limits

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.; Juarez, Alfredo; Peyton, Gary J.; Harper, Susana A.; Olson, Sandra L.

    2011-01-01

    NASA-STD-(I)-6001B Test 1 is currently used to evaluate the flammability of materials intended for use in habitable environments of U.S. spacecraft. The method is a pass/fail upward flame propagation test conducted in the worst case configuration, which is defined as a combination of a material s thickness, test pressure, oxygen concentration, and temperature that make the material most flammable. Although simple parametric effects may be intuitive (such as increasing oxygen concentrations resulting in increased flammability), combinations of multi-parameter effects could be more complex. In addition, there are a variety of material configurations used in spacecraft. Such configurations could include, for example, exposed free edges where fire propagation may be different when compared to configurations commonly employed in standard testing. Studies involving combined oxygen concentration, pressure, and temperature on flammability limits have been conducted and are summarized in this paper. Additional effects on flammability limits of a material s thickness, mode of ignition, burn-length criteria, and exposed edges are presented. The information obtained will allow proper selection of ground flammability test conditions, support further studies comparing flammability in 1-g with microgravity and reduced gravity environments, and contribute to persuasive scientific cases for rigorous space system fire risk assessments.

  7. A coupled high-resolution modeling system to simulate biomass burning emissions, plume rise and smoke transport in real time over the contiguous US

    NASA Astrophysics Data System (ADS)

    Ahmadov, R.; Grell, G. A.; James, E.; Freitas, S.; Pereira, G.; Csiszar, I. A.; Tsidulko, M.; Pierce, R. B.; McKeen, S. A.; Saide, P.; Alexander, C.; Benjamin, S.; Peckham, S.

    2016-12-01

    Wildfires can have huge impact on air quality and visibility over large parts of the US. It is quite challenging to accurately predict wildfire air quality given significant uncertainties in modeling of biomass burning (BB) emissions, fire size, plume rise and smoke transport. We developed a new smoke modeling system (HRRR-Smoke) based on the coupled meteorology-chemistry model WRF-Chem. The HRRR-Smoke modeling system uses fire radiative power (FRP) data measured by the Visible Infrared Imaging Radiometer Suite (VIIRS) sensor on the Suomi National Polar-orbiting Partnership satellite. Using the FRP data enables predicting fire emissions, fire size and plume rise more accurately. Another advantage of the VIIRS data is the fire detection and characterization at­ high spatial resolution during both day and nighttime. The HRRR-Smoke model is run in real-time for summer 2016 on 3km horizontal grid resolution over CONUS domain by NOAA/ESRL Global Systems Division (GSD). The model simulates advection and mixing of fine particulate matter (PM2.5 or smoke) emitted by calculated BB emissions. The BB emissions include both smoldering and flaming fractions. Fire plume rise is parameterized in an online mode during the model integration. In addition to smoke, anthropogenic emissions of PM2.5 are transported in an inline mode as a passive tracer by HRRR-Smoke. The HRRR-Smoke real-time runs use meteorological fields for initial and lateral boundary conditions from the experimental real-time HRRR(X) numerical weather prediction model also run at NOAA/ESRL/GSD. The model is initialized every 6 hours (00, 06, 12 and 18UTC) daily using newly generated meteorological fields and FRP data obtained during previous 24 hours. Then the model produces meteorological and smoke forecasts for next 36 hours. The smoke fields are cycled from one forecast to the next one. Predicted near-surface and vertically integrated smoke concentrations are visualized online on a web-site: http://rapidrefresh.noaa.gov/HRRRsmoke/In this talk, we discuss the major components of the HRRR-Smoke modeling system. We present modeled smoke fields for some major wildfire cases over the western US in 2016 and discuss the model performance for those cases.

  8. Utilization of geoinformation tools for the development of forest fire hazard mapping system: example of Pekan fire, Malaysia

    NASA Astrophysics Data System (ADS)

    Mahmud, Ahmad Rodzi; Setiawan, Iwan; Mansor, Shattri; Shariff, Abdul Rashid Mohamed; Pradhan, Biswajeet; Nuruddin, Ahmed

    2009-12-01

    A study in modeling fire hazard assessment will be essential in establishing an effective forest fire management system especially in controlling and preventing peat fire. In this paper, we have used geographic information system (GIS), in combination with other geoinformation technologies such as remote sensing and computer modeling, for all aspects of wild land fire management. Identifying areas that have a high probability of burning is an important component of fire management planning. The development of spatially explicit GIS models has greatly facilitated this process by allowing managers to map and analyze variables contributing to fire occurrence across large, unique geographic units. Using the model and its associated software engine, the fire hazard map was produced. Extensive avenue programming scripts were written to provide additional capabilities in the development of these interfaces to meet the full complement of operational software considering various users requirements. The system developed not only possesses user friendly step by step operations to deliver the fire vulnerability mapping but also allows authorized users to edit, add or modify parameters whenever necessary. Results from the model can support fire hazard mapping in the forest and enhance alert system function by simulating and visualizing forest fire and helps for contingency planning.

  9. Impact air quality by wildfire and agricultural fire in Mexico city 2015

    NASA Astrophysics Data System (ADS)

    Mendoza Campos, Alejandra; Agustín García Reynoso, José; Castro Romero, Telma Gloria; Carbajal Pérez, José Noel; Mar Morales, Bertha Eugenia; Gerardo Ruiz Suárez, Luis

    2016-04-01

    A forest fire is a large-scale process natural combustion where different types of flora and fauna of different sizes and ages are consumed. Consequently, forest fires are a potential source of large amounts of air pollutants that must be considered when trying to relate emissions to the air quality in neighboring cities of forest areas as in the Valley of Mexico. The size, intensity and occurrence of a forest fire directly dependent variables such as weather conditions, topography, vegetation type and its moisture content and the mass of fuel per hectare. An agricultural fire is a controlled combustion, which occurred a negligence can get out of control and increase the burned area or the possibly become a wildfire. Once a fire starts, the dry combustible material is consumed first. If the energy release is large and of sufficient duration, drying green material occurs live, with subsequent burning it. Under proper fuel and environmental conditions, this process can start a chain reaction. These events occur mainly in the dry season. Forest fires and agriculture fires contribute directly in the increase of carbon dioxide (CO2) into the atmosphere; The main pollutants emitted to the atmosphere by a wildfire are the PM10, PM2.5, NOx and VOC's, the consequences have by fire are deforestation, soil erosion or change of structure and composition of forests (Villers, 2006), also it affects ecosystems and the health of the population. In this study the impact of air quality for the emissions of particulate matter less than ten microns PM10, by wildfire and agricultural fire occurred on the same day and same place, the study was evaluated in Mexico City the Delegation Milpa Alta in the community of San Lorenzo Tlacoyucan, the fire occurred on 3rd March, 2015, the wildfire duration 12 hours consuming 32 hectares of oak forest and the agricultural fire duration 6 hours consumed 16 hectares of corn. To evaluate the impact of air quality the WRF-Chem, WRF-Fire and METv3 models were used, four scenarios were made, in the first forest fire emissions were included, in the second agricultural fire emissions were included, the third was the difference between agricultural burning and forest fire and the last stage model without fire emissions. In making the interpolation of the modeled scenarios forest and agricultural fires the impact of air quality in the Valley of Mexico was obtained by increasing the concentration of particles smaller than ten micrometers PM10, with the results of the modeling are obtained that the PM10 concentration is ten times higher in the wildfire regarding agricultural fire. By making interpolation between this difference and considering the fire scenario without emissions by that date, a maximum PM10 concentration was 170μg /m3 during the hours of the fires, which exceeds the Mexican standard NOM-025-SSA1-2014 that provides that the maximum allowable limit of exposure to particulate matter less than ten microns is 75μg/m3 on average 24 hours, forest and agricultural fires have an impact of 226% in the PM10 air quality affecting ecosystems and human health

  10. Amended Ballistic Sand Studies to Provide Low Maintenance Lead Containment at Active Small Arms Firing Range Systems

    DTIC Science & Technology

    2007-09-01

    Pb2+. Under alkaline conditions, elemental lead will oxidize under most circumstances to form a lead hydroxide complex Pb(OH)53-. Lead that exists...lead hydroxide [Pb(OH)2], lead carbonate [PbCO3, cerrusite], or basic lead carbonate [Pb3(OH)2 (CO3)2, hydrocerrusite]. The overall lead solubility...in a natural system is fundamentally determined by the concentrations of the anions in solution (e.g., the hydroxide and carbonate ions) and by the

  11. Wire-reinforced endotracheal tube fire during tracheostomy -A case report-.

    PubMed

    Shin, Young Duck; Lim, Seung-Woon; Bae, Jin Ho; Yim, Kyoung Hoon; Sim, Jae Hwan; Kwon, Eun Jung

    2012-08-01

    Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO(2) with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire.

  12. An assessment of air quality impacts of fires associated with fire fighting operations.

    PubMed

    Leahey, D M; Hansen, M C; Schroeder, M B

    1993-03-01

    Fire fighters in Canada's navy must undergo regular training with fires from simulated helicopter crashes. Visible emissions from these fires often create health concerns in surrounding communities. This paper presents air quality implications of plume dispersion associated with "helicopter fires." Evaluations involved measuring plume rise, estimating emissions, dispersion modeling and ambient monitoring. Results of the evaluation provided ground-level concentration estimates of plume particulate matter, oxides of nitrogen, hydrogen fluoride, carbon monoxide, 22 metals, 15 PAH and 13 VOC. The study showed that the air quality impact of the fire fighting training is much lower than the relevant time-weighted averages established to protect workers' health. This paper will be of interest to people in environmental protection agencies because it demonstrates the effects of fire fighting operations that must frequently occur as part of training exercises.

  13. Wire-reinforced endotracheal tube fire during tracheostomy -A case report-

    PubMed Central

    Shin, Young Duck; Bae, Jin Ho; Yim, Kyoung Hoon; Sim, Jae Hwan; Kwon, Eun Jung

    2012-01-01

    Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO2 with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire. PMID:22949984

  14. 14 CFR 121.273 - Fire-detector systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire-detector systems. 121.273 Section 121.273 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED...-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to...

  15. 14 CFR 121.273 - Fire-detector systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fire-detector systems. 121.273 Section 121.273 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED...-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to...

  16. 14 CFR 121.273 - Fire-detector systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Fire-detector systems. 121.273 Section 121.273 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED...-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to...

  17. 14 CFR 121.273 - Fire-detector systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fire-detector systems. 121.273 Section 121.273 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED...-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to...

  18. 14 CFR 121.273 - Fire-detector systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fire-detector systems. 121.273 Section 121.273 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED...-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to...

  19. Analysis of the Influence of Construction Insulation Systems on Public Safety in China

    PubMed Central

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-01-01

    With the Government of China’s proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies. PMID:27589774

  20. Analysis of the Influence of Construction Insulation Systems on Public Safety in China.

    PubMed

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-08-30

    With the Government of China's proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies.

Top