Zelefsky, Michael J; Greco, Carlo; Motzer, Robert; Magsanoc, Juan Martin; Pei, Xin; Lovelock, Michael; Mechalakos, Jim; Zatcky, Joan; Fuks, Zvi; Yamada, Yoshiya
2014-01-01
Purpose To report tumor local progression-free outcomes following treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Methods and Materials Between 2004 and 2010, a total of 105 lesions from renal cell carcinomas were treated with either SD-IGRT to prescription doses of 18–24 Gy (median, 24 Gy) or hypofractionation (3 or 5 fractions) with prescription doses ranging between 20 and 30 Gy. The median follow-up was 12 months (range, 1–48 months). Results The overall 3-year actuarial local progression-free survival (LPFS) for all lesions was 44%. The 3-year LPFS for those who received high single-dose (24 Gy; n = 45), low single-dose (< 24 Gy; n = 14), and hypofractionation regimens (n = 46) were 88%, 21%, and 17%, respectively (high single dose versus low single dose, p = 0.001; high single dose versus hypofractionation, p < 0.001). Multivariate analysis revealed the following variables as significant predictors of improved LPFS: dose of 24 Gy compared with lower dose (p = 0.009), and single dose versus hypofractionation (p = 0.008). Conclusion High-dose SD-IGRT is a non-invasive procedure resulting in high probability of local tumor control for metastatic renal cell cancers, generally considered radioresistant according to classical radiobiological ranking. PMID:21596489
Berry, Donald A.; Ueno, Naoto T.; Johnson, Marcella M.; Lei, Xiudong; Caputo, Jean; Smith, Dori A.; Yancey, Linda J.; Crump, Michael; Stadtmauer, Edward A.; Biron, Pierre; Crown, John P.; Schmid, Peter; Lotz, Jean-Pierre; Rosti, Giovanni; Bregni, Marco; Demirer, Taner
2011-01-01
Purpose High doses of effective chemotherapy are compelling if they can be delivered safely. Substantial interest in supporting high-dose chemotherapy with bone marrow or autologous hematopoietic stem-cell transplantation in the 1980s and 1990s led to the initiation of randomized trials to evaluate its effect in the treatment of metastatic breast cancer. Methods We identified six randomized trials in metastatic breast cancer that evaluated high doses of chemotherapy with transplant support versus a control regimen without stem-cell support. We assembled a single database containing individual patient information from these trials. The primary analysis of overall survival was a log-rank test comparing high dose versus control. We also used Cox proportional hazards regression, adjusting for known covariates. We addressed potential treatment differences within subsets of patients. Results The effect of high-dose chemotherapy on overall survival was not statistically different (median, 2.16 v 2.02 years; P = .08). A statistically significant advantage in progression-free survival (median, 0.91 v 0.69 years) did not translate into survival benefit. Subset analyses found little evidence that there are groups of patients who might benefit from high-dose chemotherapy with hematopoietic support. Conclusion Overall survival of patients with metastatic breast cancer in the six randomized trials was not significantly improved by high-dose chemotherapy; any benefit from high doses was small. No identifiable subset of patients seems to benefit from high-dose chemotherapy. PMID:21768454
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mwidu, U; Devic, S; Shehadeh, M
Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended bymore » the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelefsky, Michael J., E-mail: zelefskm@mskcc.org; Greco, Carlo; Motzer, Robert
2012-04-01
Purpose: To report tumor local progression-free outcomes after treatment with single-dose, image-guided, intensity-modulated radiotherapy and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Patients and Methods: Between 2004 and 2010, 105 lesions from renal cell carcinoma were treated with either single-dose, image-guided, intensity-modulated radiotherapy to a prescription dose of 18-24 Gy (median, 24) or hypofractionation (three or five fractions) with a prescription dose of 20-30 Gy. The median follow-up was 12 months (range, 1-48). Results: The overall 3-year actuarial local progression-free survival for all lesions was 44%. The 3-year local progression-free survival for those who received a highmore » single-dose (24 Gy; n = 45), a low single-dose (<24 Gy; n = 14), or hypofractionation regimens (n = 46) was 88%, 21%, and 17%, respectively (high single dose vs. low single dose, p = .001; high single dose vs. hypofractionation, p < .001). Multivariate analysis revealed the following variables were significant predictors of improved local progression-free survival: 24 Gy dose compared with a lower dose (p = .009) and a single dose vs. hypofractionation (p = .008). Conclusion: High single-dose, image-guided, intensity-modulated radiotherapy is a noninvasive procedure resulting in high probability of local tumor control for metastatic renal cell cancer generally considered radioresistant according to the classic radiobiologic ranking.« less
Accelerated heavy particles and the lens. VII: The cataractogenic potential of 450 MeV/amu iron ions
NASA Technical Reports Server (NTRS)
Worgul, B. V.; Brenner, D. J.; Medvedovsky, C.; Merriam, G. R. Jr; Huang, Y.
1993-01-01
PURPOSE. To determine the cataractogenic potential dose of high velocity iron ions as a fixation of dose administered singly or fractionated. The dose is critical to risk assessment and to theories of radiation action and cataractogenesis. METHODS. Twenty-eight-day-old rats were examined by slit-lamp biomicroscopy on a weekly-bi-weekly basis for more than 2 yr after radiation exposure. For the acute exposure study doses of 1, 2, 5, 25, and 50 cGy were evaluated. The fractionated regimens involved total doses of 2, 25, and 50 cGy. The reference radiation consisted of 50, 100, 200, or 700 cGy of 250 kilovolt (peak) x-rays. RESULTS. In accordance with previous findings in the rat using 570 MeV/amu 40Ar ions, the relative biologic effectiveness increased rapidly with decreasing dose, reaching values as high as 100. Unlike 40Ar ions, fractionation of the 56Fe doses did not produce a consistent enhancement at any of the doses examined. CONCLUSIONS. The data support the previous findings of a high cataractogenic potential for high linear energy transfer (LET) radiation. The effectiveness for the production of cataracts increases with decreasing dose relative to x-rays and is independent of dose protraction. Although the present study did not reveal a consistent enhancement of effect when the ions were applied in fractions, the results are consistent with at least one theory of the inverse dose-rate effect observed for high-LET radiation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greco, Carlo; Zelefsky, Michael J., E-mail: zelefskm@mskcc.or; Lovelock, Michael
2011-03-15
Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy),more » intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.« less
Bejder, Jacob; Aachmann-Andersen, Niels Jacob; Bonne, Thomas Christian; Olsen, Niels Vidiendal; Nordsborg, Nikolai Baastrup
2016-10-01
The sensitivity of the adaptive model of the Athlete Biological Passport (ABP) and reticulocyte percentage (ret%) in detection of recombinant human erythropoietin (rHuEPO) misuse was evaluated using both a long-term normal dose and a brief high dose treatment regime. Sixteen subjects received either 65 IU rHuEPO × kg -1 every second day for two weeks (normal-dose), 390 IU rHuEPO × kg -1 on three consecutive days (high-dose), or frequent placebo treatment for 13 days in a randomized, placebo-controlled, double-blind crossover design. Blood variables were measured 4, 11, and 25 days following treatment initiation. The ABP based on haemoglobin concentration ([Hb]) and OFF-hr score ([Hb] - 60 × √ret%) yielded atypical profiles following both normal-dose and high-dose treatment (0 %, 31 %, 13 % vs. 21 %, 33 %, 20 % at days 4, 11, and 25 after normal and high dose, respectively). Including ret% as a stand-alone marker for atypical blood profiles increased (P < 0.05) the sensitivity of the adaptive model at day 11 to 63 % and 67 % for normal-dose and high-dose rHuEPO administration, respectively. In conclusion, ~30 % of subjects injecting a normal-dose rHuEPO for two weeks or a high-dose rHuEPO for three days will present an atypical ABP profile. Including ret% as a stand-alone parameter improves the sensitivity two-fold. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Low, but not high, dose caffeine is a readily available probe for adenosine actions.
Fredholm, Bertil B; Yang, Jiangning; Wang, Yingqing
2017-06-01
Caffeine is very widely used and knowledge of its mode of action can be used to gain an understanding of basal physiological regulation. This review makes the point that caffeine is - in low doses - an antagonist of adenosine acting at A 1 , A 2A and A 2B receptors. We use published and unpublished data to make the point that high dose effects of caffeine are not only qualitatively different but have a different underlying mechanism. Therefore one must be careful in only using epidemiological or experimental data where rather low doses of caffeine are used to draw conclusions about the physiology and pathophysiology of adenosine. Copyright © 2016 Elsevier Ltd. All rights reserved.
Antipsychotic doses among community-dwelling persons with Alzheimer disease in Finland.
Taipale, Heidi; Koponen, Marjaana; Tanskanen, Antti; Tolppanen, Anna-Maija; Tiihonen, Jari; Hartikainen, Sirpa
2014-08-01
Use of antipsychotics for treatment of behavioral and psychological symptoms of dementia is frequent among persons with Alzheimer disease (AD). Doses used in long-term therapy have not been previously reported. We describe antipsychotic doses used among community-dwelling persons with AD and investigate factors associated with high-dose use. The MEDALZ-2005 (Medication use and Alzheimer disease) cohort is a nationwide sample including all persons with clinically diagnosed AD at the end of year 2005 in Finland (n = 28,093). Data including prescriptions, comorbidities, and hospital discharge diagnoses were collected from nationwide registers. Antipsychotic doses in monotherapy were investigated during 2006 to 2009. Among 8920 antipsychotic users, 4% (n = 336) used antipsychotics with high dose. Typical antipsychotics were more often used with high dose than atypical antipsychotics. High-dose use was associated with younger age (<80 years) (odds ratio [OR], 1.71; 95% confidence interval [CI], 1.36-2.15]), male sex (OR, 1.52; CI, 1.21-1.91), history of psychiatric disorder (OR, 3.25; CI, 2.54-4.15), and inversely associated with Charlson Comorbidity Index score (score 1: OR, 0.74; CI, 0.57-0.97; score ≥2: OR, 0.68; CI, 0.47-0.97). In conclusion, the majority of persons with AD used antipsychotics with low or medium dose. Typical antipsychotics were more often used with high dose than atypical antipsychotics, which indicates a need for precise dosing instructions in the treatment of behavioral and psychological symptoms of dementia. Clinicians should regularly assess dosing levels especially among men and those with history of psychiatric disorder.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Jung, H; Kim, M
2014-06-01
Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulatedmore » dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.« less
Mohamed, Hanaa Mahmoud; Mohamed, Manal Abdul-Hamid
2015-01-01
The present study aims of to investigate the effects of low and high doses of nandrolone decanoate (ND) on histopathology and apoptosis of the spermatogenic cells as well as lipid peroxidation, antioxidant enzyme activities, sperm abnormality and DNA fragmentation. Eighteen animals were divided into three groups each group contain six animals. The rats were divided into three groups as following: Group 1 was administered saline (control). Group 2, received nandrolone decanoate (3 mg/kg/weekly) (low dose) with intramuscular injection. Group 3, received intramuscular injection dose of nandrolone decanoate (10 mg/kg/weekly) (high dose). After 8 weeks, caspase-3 assay was used to determine the apoptotic cells. The sperm parameters, lipid peroxidation, antioxidant enzyme activities and testosterone concentration were also investigated in the experimental groups of both low and high dose compared to the control groups. Treated group with high dose showed degenerated germinal epithelial cells sloughed in the lumina of seminiferous tubules, where almost seminiferous tubules were devoid of spermatids and spermatozoa compared to control and group treated with low dose. Also, a significant increase of lipid peroxidation levels and heat shock proteins was observed in two groups administrated with two different doses of ND while, antioxidant enzyme activities, and testosterone concentration was significantly decreased in two treated group when compared with control. Administration of ND at high and low doses leads to deteriorated sperm parameters, DNA fragmentation and testicular apoptosis. In conclusion, the administration ND at high doses more effective on lipid peroxidation, antioxidant enzyme activities, sperm abnormality, histopathology, apoptotic and DNA changes compared to low dose group and to control group. Published by Elsevier GmbH.
Older adults and high-risk medication administration in the emergency department
Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J
2017-01-01
Background Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). Patients and methods ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated (“High doses” were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; “very high doses” were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65–69, 70–74, 75–79, 80–84, and ≥85 years), gender, and hospital. Results There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65–69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56–11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69–18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26–1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07–2.16). Conclusion Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65–69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted. PMID:29184448
Krysiak, R; Szkróbka, W; Okopień, B
2016-10-01
Background: Intensive statin therapy was found to reduce thyroid autoimmunity in women with Hashimoto's thyroiditis. No similar data are available for other hypolipidemic agents. Methods: The participants of the study were 16 women with Hashimoto's thyroiditis and coronary artery disease. On the basis of statin tolerance, they were divided into 2 groups. 8 patients who did not tolerate high-dose statin therapy were treated with a statin, the dose of which was reduced by half, together with ezetimibe. The remaining 8 patients tolerating the treatment continued high-dose statin therapy. Plasma lipids, serum levels of thyrotropin, free thyroxine and free triiodothyronine, as well as titers of thyroid peroxidase and thyroglobulin antibodies were measured at the beginning of the study and 6 months later. Results: Replacing high-dose statin therapy with ezetimibe/statin combination therapy increased serum titers of thyroid peroxidase as well as led to an insignificant increase in serum titers of thyroglobulin antibodies. At the end of the study, thyroid peroxidase and thyroglobulin antibody titers were higher in patients receiving the combination therapy than in those treated only with high-dose statin. Conclusions: Our study shows that high-dose statin therapy produces a stronger effect on thyroid autoimmunity than ezetimibe/statin combination therapy. © Georg Thieme Verlag KG Stuttgart · New York.
Bremsstrahlung Dose Yield for High-Intensity Short-Pulse Laser–Solid Experiments
Liang, Taiee; Bauer, Johannes M.; Liu, James C.; ...
2016-12-01
A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2. This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of thismore » paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.« less
Bremsstrahlung Dose Yield for High-Intensity Short-Pulse Laser–Solid Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Taiee; Bauer, Johannes M.; Liu, James C.
A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2. This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of thismore » paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.« less
Effect of Qingnao tablet on blood viscosity of rat model of blood stasis induced by epinephrine
NASA Astrophysics Data System (ADS)
Xie, Guoqi; Hao, Shaojun; Ma, Zhenzhen; Liu, Xiaobin; Li, Jun; Li, Wenjun; Zhang, Zhengchen
2018-04-01
To establish a rat model of blood stasis with adrenaline (Adr) subcutaneous injection and ice bath stimulation. The effects of different doses on the blood viscosity of blood stasis model rats were observed. The rats were randomly divided into 6 groups: blank control group (no model), model group, positive control group, high, middle and low dose group. The whole blood viscosity and plasma viscosity were detected by blood viscosity instrument. Compared with the blank group, model group, high shear, low shear whole blood viscosity and plasma viscosity were significantly increased, TT PT significantly shortened, APTT was significantly prolonged, FIB increased significantly, indicating that the model was successful. Compared with the model group, can significantly reduce the Naoluotong group (cut, low cut). Qingnaopian high dose group (low cut), middle dose group (cut, low shear blood viscosity) (P<0.01), Can significantly reduce Naoluotong qingnaopian group, high dose group (P<0.01), plasma viscosity decreased qingnaopian plasma viscosity in low dose group (P<0.05). Conclusion: qingnaopian could improve the blood rheology of blood stasis mice abnormal index, decrease the blood viscosity, blood stasis has certain hemostatic effect.
Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J
2016-01-01
Aim Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients and methods Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3–6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. Results In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. Conclusion There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered. PMID:27274277
Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?
Day, Troy; Read, Andrew F.
2016-01-01
High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986
Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?
Day, Troy; Read, Andrew F
2016-01-01
High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients.
Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans
Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.
2012-01-01
BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498
Tuberculosis in Newborns: The Lessons of the “Lübeck Disaster” (1929–1933)
Fox, Gregory J.; Orlova, Marianna; Schurr, Erwin
2016-01-01
In an accident later known as the Lübeck disaster, 251 neonates were orally given three doses of the new Bacille Calmette–Guérin (BCG) antituberculosis (TB) vaccine contaminated with Mycobacterium tuberculosis. A total of 173 infants developed clinical or radiological signs of TB but survived the infection, while 72 died from TB. While some blamed the accident on BCG itself by postulating reversion to full virulence, such a possibility was conclusively disproven. Rather, by combining clinical, microbiological, and epidemiological data, the chief public health investigator Dr. A. Moegling concluded that the BCG vaccine had been contaminated with variable amounts of fully virulent M. tuberculosis. Here, we summarize the conclusions drawn by Moegling and point out three lessons that can be learned. First, while mortality was high (approximately 29%), the majority of neonates inoculated with M. tuberculosis eventually overcame TB disease. This shows the high constitutional resistance of humans to the bacillus. Second, four semiquantitative levels of contamination were deduced by Moegling from the available data. While at low levels of M. tuberculosis there was a large spread of clinical phenotypes reflecting a good degree of innate resistance to TB, at the highest dose, the majority of neonates were highly susceptible to TB. This shows the dominating role of dose for innate resistance to TB. Third, two infants inoculated with the lowest dose nevertheless died of TB, and their median time from inoculation to death was substantially shorter than for those who died after inoculation with higher doses. This suggests that infants who developed disease after low dose inoculation are those who are most susceptible to the disease. We discuss some implications of these lessons for current study of genetic susceptibility to TB. PMID:26794678
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W
2012-10-17
Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. INTERVENTION The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. The composite of HIV disease progression or death from any cause. The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96-1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11-1.87) vs standard-dose supplementation. CONCLUSION In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Clinicaltrials.gov Identifier: NCT00383669.
Spellman, Timothy; McClintock, Shawn M.; Terrace, Herbert; Luber, Bruce; Husain, Mustafa M.; Lisanby, Sarah H.
2008-01-01
Background Magnetic seizure therapy (MST) is under investigation as an alternative form of convulsive therapy that induces more focal seizures and spares cortical regions involved in memory. Using a newly expanded version of the Columbia University Primate Cognitive Profile, we compared the cognitive effects of high-dose MST delivered at 100 Hz (6X seizure threshold) with electroconvulsive shock (ECS) delivered at 2.5X seizure threshold. Methods Daily high-dose MST, ECS, and Sham (anesthesia-only) were administered for 4 weeks each in a within-subject cross-over design. Rhesus macaques (n = 3) were trained on five cognitive tasks assessing automatic memory, anterograde learning and memory, combined anterograde and retrograde simultaneous chaining, and spatial and serial working memory. Acutely following each intervention, monkeys were tested on the cognitive battery twice daily, separated by a 3-hour retention interval. Results Subjects were slower to complete criterion tasks (p’s<0.0001) following ECS, compared to sham and high-dose MST. Moreover, time to task-completion following high-dose MST did not differ from sham. Out of 6 measures of accuracy, treatment effects were found in 4; in all of these, ECS, but not MST, fared worse than Sham. On all accuracy and time to completion measurements, subjects performed as well as following high-dose MST as did subjects from a previous study on moderate-dose MST. Conclusion These findings provide evidence that high-dose MST results in benign acute cognitive side-effect profile relative to ECS, and are in line with our previous studies. PMID:18262171
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Percy, E-mail: percylee@mednet.ucla.edu; UCLA Jonsson Comprehensive Cancer Center, Los Angeles, California; Eppinga, Wietse
Purpose: Cancer stem cells (CSCs) may play a role in the recurrence of glioblastoma. They are believed to originate from neural stem cells in the subventricular zone (SVZ). Because of their radioresistance, we hypothesized that high doses of radiation (>59.4 Gy) to the SVZ are necessary to control CSCs and improve progression-free survival (PFS) or overall survival (OS) in glioblastoma. Methods and Materials: 173 patients with glioblastoma pooled from 2 academic centers were treated with resection followed by chemoradiation therapy. The SVZ was segmented on computed tomography to calculate radiation doses delivered to the presumptive CSC niches. The relationships betweenmore » high SVZ doses and PFS and OS were examined using Cox proportional hazards models. Five covariates were included to estimate their impact on PFS or OS: ipsilateral and contralateral SVZ doses, clinical target volume dose, age, and extent of resection. Results: Median PFS and OS were 10.4 and 19.6 months for the cohort. The mean ipsilateral SVZ, contralateral SVZ, and clinical target volume doses were 49.2, 35.2, and 60.1 Gy, respectively. Twenty-one patients who received high ipsilateral SVZ dose (>59.4 Gy) had significantly longer median PFS (12.6 vs 9.9 months, P=.042) and longer OS (25.8 vs 19.2 months, P=.173). On multivariate analysis, high radiation therapy doses to ipsilateral SVZ remained a statistically significant independent predictor of improved PFS but not of OS. The extent of surgery affected both PFS and OS on multivariate analysis. Conclusion: High radiation therapy doses to ipsilateral CSC niches are associated with improved PFS in glioblastoma.« less
Dose-dependent effects of vitamin 1,25(OH)2D3 on oxidative stress and apoptosis.
Cakici, Cagri; Yigitbasi, Turkan; Ayla, Sule; Karimkhani, Hadi; Bayramoglu, Feyza; Yigit, Pakize; Kilic, Ertugrul; Emekli, Nesrin
2018-02-08
Background The purpose of this study is to examine the dose-dependent effects of vitamin 1,25(OH)2D3 on apoptosis and oxidative stress. Methods In this study, 50 male Balb/c mice were used as control and experiment groups. The mice were divided into 5 groups each consisting of 10 mice. Calcitriol was intraperitoneally administered as low dose, medium dose, medium-high dose and high dose vitamin D groups (at 0.5, 1, 5 and 10 μg/kg, respectively), for three times a week during 14 days. At the end of the study, annexin V was measured by enzyme-linked immunosorbent assay method, and total antioxidant capacity and total oxidant status values were measured by colorimetric method in serum. Hematoxylin eosin staining was performed in liver tissues and periodic acid schiff staining was performed in kidney tissues. Results While comparing the results of medium-high dose (5 μg/kg) and high dose (10 μg/kg) vitamin D administration to that of the control group, it was observed that serum antioxidant status and annexin V levels decreased and glomerular mesenchial matrix ratio increased in kidney (p<0.05). In addition to these findings, in the group receiving high dose vitamin D (10 μg/kg), it was observed that the damage to the liver increased together with the the oxidative stress index values (p<0.05). Conclusions As a result, this study was the first in the literature to report that use of high-dose vitamin D (10 μg/kg) results in oxidant effect, rather than being an antioxidant, and causes severe histopathological toxicity in the liver and kidney.
Booster and higher antigen doses of inactivated influenza vaccine in HIV-infected patients.
Johnston, Jessica A; Tincher, Lindsey B; Lowe, Denise K
2013-12-01
To review the literature regarding booster or higher doses of influenza antigen for increasing immunogenicity of inactivated influenza vaccine (IIV) in HIV-infected patients. MEDLINE (1966 to September 2013) was searched using the terms immunize, influenza, vaccine, and HIV or AIDS in combination with two-dose, booster-dose, increased antigen, or high-dose. One trial of booster dosing with standard doses (SDs) of IIV, trivalent (IIV3); 2 trials of booster dosing with intermediate doses (ID) of H1N1 IIV or IIV3; and 1 trial of high-dose (HD) IIV3 were identified. Trials administering 2-dose, booster-dose, or increased antigen of influenza vaccine to patients with HIV were reviewed. Because adjuvanted IIV is not available and IIV, quadrivalent was recently approved in the United States, studies evaluating these vaccines were excluded. HIV-infected individuals are at high risk for influenza-related complications; however, vaccination with SD IIV may not confer optimal protection. It has been postulated that booster or higher doses of influenza antigen may lead to increased immunogenicity. When ID and SD or ID with boosters were evaluated in HIV-infected patients, significant increases in surrogate markers for influenza protection were not achieved. However, HD IIV3 did result in significant increases in seroprotective antibody levels, though 'clinical' influenza was not evaluated. Currently, evidence is insufficient to reach conclusions about the efficacy of booster dosing, ID, or HD influenza vaccine in HIV-infected patients. Trials evaluating booster or higher-antigen doses of IIV for 'clinical' influenza are necessary before routinely recommending for HIV-infected patients.
Ota, Kazuhiro; Takeuchi, Toshihisa; Nouda, Sadaharu; Ozaki, Haruhiko; Kawaguchi, Shinpei; Takahashi, Yoshiaki; Harada, Satoshi; Edogawa, Shoko; Kojima, Yuichi; Kuramoto, Takanori; Higuchi, Kazuhide
2016-11-01
Small intestinal mucosal injury caused by low-dose aspirin is a common cause of obscure gastrointestinal bleeding. We aimed to investigate the protective effects and optimal dose of rebamipide for low-dose aspirin-induced gastrointestinal mucosal injury. In this prospective randomized trial, 45 healthy volunteers (aged 20-65 years) were included and divided into three groups. The groups received enteric-coated aspirin 100 mg (low-dose aspirin) plus omeprazole 10 mg (Group A: proton pump inhibitor group), low-dose aspirin plus rebamipide 300 mg (Group B: standard-dose group), or low-dose aspirin plus rebamipide 900 mg (Group C: high-dose group). Esophagogastroduodenoscopy and video capsule endoscopy were performed, and the fecal occult blood reaction and fecal calprotectin levels were measured before and two weeks after drug administration. Although the fecal calprotectin levels increased significantly in Group A, they did not increase in Groups B and C. The esophagogastroduodenoscopic and video capsule endoscopic findings and the fecal occult blood test findings did not differ significantly among the three groups. In conclusion, standard-dose rebamipide is sufficient for preventing mucosal injury of the small intestine induced by low-dose aspirin, indicating that high-dose rebamipide is not necessary.
Non-Malignant Thyroid Diseases Following a Wide Range of Radiation Exposures
Ron, Elaine; Brenner, Alina
2013-01-01
Background The thyroid gland is one of the most radiosensitive human organs. While it is well known that radiation exposure increases the risk of thyroid cancer, less is known about its effects in relation to non-malignant thyroid diseases. Objectives The aim of this review is to evaluate the effects of high and low dose radiation on benign structural and functional diseases of the thyroid. Methods We examined the results of major studies from cancer patients treated with high-dose radiotherapy or thyrotoxicosis patients treated with high doses of iodine-131, patients treated with moderate to high dose radiotherapy for benign diseases, persons exposed to low doses from environmental radiation and survivors of the atomic bombings who were exposed to a range of doses. We evaluated radiation effects on structural (tumors, nodules), functional (hyper- and hypothyroidism), and autoimmune thyroid diseases. Results Following a wide range of doses of ionizing radiation, an increased risk of thyroid adenomas and nodules was observed in a variety of populations and settings. The dose response appeared to be linear at low to moderate doses, but in one study there was some suggestion of a reduction in risk above 5 Gy. The elevated risk for benign tumors continues for decades following exposure. Considerably less consistent findings are available regarding functional thyroid diseases including autoimmune diseases. In general, associations for these outcomes were fairly weak and significant radiation effects were most often observed following high doses, particularly for hypothyroidism. Conclusions A significant radiation dose-response relation was demonstrated for benign nodules and follicular adenomas. The effects of radiation on functional thyroid diseases are less clear, partly due to the greater difficulties studying these diseases. PMID:21128812
Devidas, Meenakshi; Chen, Si; Salzer, Wanda L.; Raetz, Elizabeth A.; Loh, Mignon L.; Mattano, Leonard A.; Cole, Catherine; Eicher, Alisa; Haugan, Maureen; Sorenson, Mark; Heerema, Nyla A.; Carroll, Andrew A.; Gastier-Foster, Julie M.; Borowitz, Michael J.; Wood, Brent L.; Willman, Cheryl L.; Winick, Naomi J.; Hunger, Stephen P.; Carroll, William L.
2016-01-01
Purpose Survival for children and young adults with high-risk B-acute lymphoblastic leukemia has improved significantly, but 20% to 25% of patients are not cured. Children’s Oncology Group study AALL0232 tested two interventions to improve survival. Patients and Methods Between January 2004 and January 2011, AALL0232 enrolled 3,154 participants 1 to 30 years old with newly diagnosed high-risk B-acute lymphoblastic leukemia. By using a 2 × 2 factorial design, 2,914 participants were randomly assigned to receive dexamethasone (14 days) versus prednisone (28 days) during induction and high-dose methotrexate versus Capizzi escalating-dose methotrexate plus pegaspargase during interim maintenance 1. Results Planned interim monitoring showed the superiority of the high-dose methotrexate regimens, which exceeded the predefined boundary and led to cessation of enrollment in January 2011. At that time, participants randomly assigned to high-dose methotrexate during interim maintenance 1 versus those randomly assigned to Capizzi methotrexate had a 5-year event-free survival (EFS) of 82% versus 75.4% (P = .006). Mature final data showed 5-year EFS rates of 79.6% for high-dose methotrexate and 75.2% for Capizzi methotrexate (P = .008). High-dose methotrexate decreased both marrow and CNS recurrences. Patients 1 to 9 years old who received dexamethasone and high-dose methotrexate had a superior outcome compared with those who received the other three regimens (5-year EFS, 91.2% v 83.2%, 80.8%, and 82.1%; P = .015). Older participants derived no benefit from dexamethasone during induction and experienced excess rates of osteonecrosis. Conclusion High-dose methotrexate is superior to Capizzi methotrexate for the treatment of high-risk B-acute lymphoblastic leukemia, with no increase in acute toxicity. Dexamethasone given during induction benefited younger children but provided no benefit and was associated with a higher risk of osteonecrosis among participants 10 years and older. PMID:27114587
Su, Qiang; Guo, Wenqin; Dai, Weiran; Li, Hongqing; Yang, Huafeng; Li, Lang
2017-01-01
Background Acute coronary syndrome (ACS) is an important disease threatening human life and health. Many studies have shown that the loading dose of atorvastatin can significantly improve the prognosis of patients with ACS, and reduce the mortality. However, this conclusion is not consistent. Thus, we aimed to evaluate the effect of high-dose rosuvastatin loading before percutaneous coronary intervention (PCI) in Chinese patients with ACS using a meta-analysis based on a systematic review of published articles. Methods We systematically reviewed published studies, evaluating the effect of high-dose rosuvastatin loading before percutaneous coronary intervention in Chinese patients with ACS. The retrieval time is limited from inception to 2 November 2016, and the retrieved databases included PubMed, Embase, the Cochrane Library, Web of Science, CBM, CNKI, the VIP database and the Wang Fang database. Two researchers independently assessed the quality of the included studies and then extracted the data. Stata 11.0 was used for data analysis. Results In total, 11 articles, which included 802 patients, were included in our meta-analysis. Among these patients, 398 patients were in the high-dose group (20 mg/day) and 404 patients were in the conventional dose group (10 mg/day). Meta-analysis results showed that compared with the conventional dose group: 1) The loading dose of rosuvastatin can significantly reduce the hs-CRP level after PCI, including at 24 hours (SMD = -0.65, 95%CI -0.84 ~ -0.47, P = 0.000), 48 hours (SMD = -0.40, 95%CI -0.68 ~ -0.11, P = 0.006), and four weeks (SMD = -1.64, 95%CI -2.01 ~ -1.26, P = 0.000). 2) The loading dose of rosuvastatin can significantly reduce the levels of LDL-C and cTnT, including the level of LDL-C at 30 d after PCI (SMD = -0.89, 95%CI -1.10 ~ -0.69, P = 0.000), and the level of cTnT at 24 h after PCI (SMD = -1.93, 95%CI -2.28 ~ -1.59, P = 0.000), and increase the level of HDL-C at 48 h after PCI (SMD = 0.61, 95%CI 0.34 ~ 0.88, P = 0.000). 3) The loading dose of rosuvastatin can significantly reduce the levels of TG and TC, including the level of TG at 30 d after PCI (SMD = -0.94, 95%CI -1.17 ~ -0.71, P = 0.000), the level of TC at 48 h after PCI (SMD = -0.35, 95%CI -0.68 ~ -0.01, P = 0.043), and the level of TC at 30 d after PCI (SMD = -0.77, 95%CI -0.98 ~ -0.56, P = 0.000). Conclusions Our systematic review and meta-analysis showed that, compared with the conventional dose, the loading dose of rosuvastatin was more beneficial to patients with ACS in China and is suitable for clinical application. Due to the limitations of the quality and quantity of included articles, this conclusion still needs to be confirmed by multicenter clinical trials. PMID:28231287
SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Y
Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. Themore » margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.« less
Modern dosimetric tools for 60Co irradiation at high containment laboratories
Twardoski, Barri; Feldmann, Heinz; Bloom, Marshall E.; Ward, Joe
2011-01-01
Purpose To evaluate an innovative photo-fluorescent film as a routine dosimetric tool during 60Co irradiations at a high containment biological research laboratory, and to investigate whether manufacturer-provided chamber exposure rates can be used to accurately administer a prescribed dose to biological specimens. Materials and methods Photo-fluorescent, lithium fluoride film dosimeters and National Institutes of Standards and Technology (NIST) transfer dosimeters were co-located in a self-shielded 60Co irradiator and exposed to γ-radiation with doses ranging from 5–85 kGy. Film dose-response relationships were developed for varying temperatures simulating conditions present when irradiating infectious biological specimens. Dose measurement results from NIST transfer dosimeters were compared to doses predicted using manufacturer-provided irradiator chamber exposure rates. Results The film dosimeter exhibited a photo-fluorescent response signal that was consistent and nearly linear in relationship to γ-radiation exposure over a wide dose range. The dosimeter response also showed negligible effects from dose fractionization and humidity. Significant disparities existed between manufacturer-provided chamber exposure rates and actual doses administered. Conclusion This study demonstrates the merit of utilizing dosimetric tools to validate the process of exposing dangerous and exotic biological agents to γ-radiation at high containment laboratories. The film dosimeter used in this study can be utilized to eliminate potential for improperly administering γ-radiation doses. PMID:21961968
2012-01-01
Background The reported health benefits of Korean red ginseng (KRG) include antioxidant, antitumor, antimutagenic, and immunomodulatory activities; however, the effects on oxidative stress have not yet been evaluated. Therefore, we assessed the effect of KRG on antioxidant enzymes and oxidative stress markers in humans. Methods We conducted a randomized, double-blind, placebo-controlled study with three groups, including placebo, low-dose (3 g/day), and high-dose (6 g/day), which were randomly assigned to healthy subjects aged 20–65 years. Lymphocyte DNA damage, antioxidative enzyme activity, and lipid peroxidation were assessed before and after the 8-week supplementation. Results Fifty-seven subjects completed the protocol. Plasma superoxide dismutase (SOD) activity after the 8-week KRG supplementation was significantly higher in the low-and high-dose groups compared to baseline. Plasma glutathione peroxidase (GPx) and catalase activities were also increased after the high-dose supplementation. Furthermore, the DNA tail length and tail moment were significantly reduced after the supplementation (low-dose and high-dose), and plasma oxidized low-density lipoprotein (LDL) levels were reduced in low-dose and high-dose groups, but increased in the placebo group. The net changes in oxidized LDL after the supplementation differed significantly between both KRG supplementation groups and the placebo group. Net changes in GPx, SOD and catalase activities, and DNA tail length and tail moment were significantly different between the high-dose group and the placebo group. Additionally, the net changes in urinary 8-epi-PGF2α were significantly different between the KRG supplementation groups and the placebo group. Conclusions KRG supplementation may attenuate lymphocyte DNA damage and LDL oxidation by upregulating antioxidant enzyme activity. PMID:22805313
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moirano, J
Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference pointmore » air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.« less
Jeong, Jae Yoon; Sohn, Joo Hyun; Baek, Yang Hyun; Cho, Yong Kyun; Kim, Yongsoo; Kim, Hyeonjin
2017-01-01
AIM To evaluate the efficacy and safety of HL tablet extracted from magnolia officinalis for treating patients with nonalcoholic fatty liver disease (NAFLD). METHODS Seventy-four patients with NAFLD diagnosed by ultrasonography were randomly assigned to 3 groups given high dose (400 mg) HL tablet, low dose (133.4 mg) HL tablet and placebo, respectively, daily for 12 wk. The primary endpoint was post-treatment change of hepatic fat content (HFC) measured by magnetic resonance spectroscopy. Secondary endpoints included changes of serum aspartate aminotransferase, alanine aminotransferase (ALT), cholesterol, triglyceride, free fatty acid, homeostasis model assessment-estimated insulin resistance, and body mass index (BMI). RESULTS The mean HFC of the high dose HL group, but not of the low dose group, declined significantly after 12 wk of treatment (high dose vs placebo, P = 0.033; low dose vs placebo, P = 0.386). The mean changes of HFC from baseline at week 12 were -1.7% ± 3.1% in the high dose group (P = 0.018), -1.21% ± 4.97% in the low dose group (P = 0.254) and 0.61% ± 3.87% in the placebo group (relative changes compared to baseline, high dose were: -12.1% ± 23.5%, low dose: -3.2% ± 32.0%, and placebo: 7.6% ± 44.0%). Serum ALT levels also tended to decrease in the groups receiving HL tablet while other factors were unaffected. There were no moderate or severe treatment-related safety issues during the study. CONCLUSION HL tablet is effective in reducing HFC without any negative lipid profiles, BMI changes and adverse effects. PMID:28932090
Clarke, Alan T.; Johnson, Paul C. D.; Hall, Gillian C.; Ford, Ian; Mills, Peter R.
2016-01-01
Background & Aims Occasional risk of serious liver dysfunction and autoimmune hepatitis during atorvastatin therapy has been reported. We compared the risk of hepatotoxicity in atorvastatin relative to simvastatin treatment. Methods The UK GPRD identified patients with a first prescription for simvastatin [164,407] or atorvastatin [76,411] between 1997 and 2006, but with no prior record of liver disease, alcohol-related diagnosis, or liver dysfunction. Incident liver dysfunction in the following six months was identified by biochemical value and compared between statin groups by Cox regression model adjusting for age, sex, year treatment started, dose, alcohol consumption, smoking, body mass index and comorbid conditions. Results Moderate to severe hepatotoxicity [bilirubin >60μmol/L, AST or ALT >200U/L or alkaline phosphatase >1200U/L] developed in 71 patients on atorvastatin versus 101 on simvastatin. Adjusted hazard ratio [AHR] for all atorvastatin relative to simvastatin was 1.9 [95% confidence interval 1.4–2.6]. High dose was classified as 40–80mg daily and low dose 10–20mg daily. Hepatotoxicity occurred in 0.44% of 4075 patients on high dose atorvastatin [HDA], 0.07% of 72,336 on low dose atorvastatin [LDA], 0.09% of 44,675 on high dose simvastatin [HDS] and 0.05% of 119,732 on low dose simvastatin [LDS]. AHRs compared to LDS were 7.3 [4.2–12.7] for HDA, 1.4 [0.9–2.0] for LDA and 1.5 [1.0–2.2] for HDS. Conclusions The risk of hepatotoxicity was increased in the first six months of atorvastatin compared to simvastatin treatment, with the greatest difference between high dose atorvastatin and low dose simvastatin. The numbers of events in the analyses were small. PMID:26983033
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spadea, Maria Francesca, E-mail: mfspadea@unicz.it; Verburg, Joost Mathias; Seco, Joao
2014-01-15
Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{submore » <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eichmann, Marion; Fluehs, Dirk; Spaan, Bernhard
2009-10-15
Purpose: The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. Methods: Inmore » order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. Results: The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. Conclusions: The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for a refined clinical treatment planning system. The improved dose rate measurements will facilitate a clinical study, which could correlate the therapeutic outcome of a brachytherapy treatment with an applicator and its individual dose rate distribution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu; Botas, Pablo; Faculty of Physics, Ruprecht-Karls-Universität Heidelberg, Heidelberg
Purpose: We describe a treatment plan optimization method for intensity modulated proton therapy (IMPT) that avoids high values of linear energy transfer (LET) in critical structures located within or near the target volume while limiting degradation of the best possible physical dose distribution. Methods and Materials: To allow fast optimization based on dose and LET, a GPU-based Monte Carlo code was extended to provide dose-averaged LET in addition to dose for all pencil beams. After optimizing an initial IMPT plan based on physical dose, a prioritized optimization scheme is used to modify the LET distribution while constraining the physical dosemore » objectives to values close to the initial plan. The LET optimization step is performed based on objective functions evaluated for the product of LET and physical dose (LET×D). To first approximation, LET×D represents a measure of the additional biological dose that is caused by high LET. Results: The method is effective for treatments where serial critical structures with maximum dose constraints are located within or near the target. We report on 5 patients with intracranial tumors (high-grade meningiomas, base-of-skull chordomas, ependymomas) in whom the target volume overlaps with the brainstem and optic structures. In all cases, high LET×D in critical structures could be avoided while minimally compromising physical dose planning objectives. Conclusion: LET-based reoptimization of IMPT plans represents a pragmatic approach to bridge the gap between purely physical dose-based and relative biological effectiveness (RBE)-based planning. The method makes IMPT treatments safer by mitigating a potentially increased risk of side effects resulting from elevated RBE of proton beams near the end of range.« less
Minguetti-Câmara, Vania C; Marques, Any de C R; Schiavon, Fabiana P M; Vilela, Vanessa R; Bruschi, Marcos L; Bazotte, Roberto Barbosa
2014-10-21
We compared the effects of oral administration of high-dose or low-dose glutamine dipeptide (GDP), alanine (ALA), glutamine (GLN), and ALA + GLN on the blood availability of amino acids in rats submitted to insulin-induced hypoglycemia (IIH). Insulin detemir (1 U/kg) was intraperitoneally injected to produce IIH; this was followed by oral administration of GDP, GLN + ALA, GLN, or ALA. We observed higher blood levels of GLN, 30 min after oral administration of high-dose GDP (1000 mg/kg) than after administration of ALA (381 mg/kg) + GLN (619 mg/kg), GLN (619 mg/kg), or ALA (381 mg/kg). However, we did not observe the same differences after oral administration of low-dose GDP (100 mg/kg) compared with ALA (38.1 mg/kg) + GLN (61.9 mg/kg), GLN (61.9 mg/kg), or ALA (38.1 mg/kg). We also observed less liver catabolism of GDP compared to ALA and GLN. In conclusion, high-dose GDP promoted higher blood levels of GLN than oral ALA + GLN, GLN, or ALA. Moreover, the lower levels of liver catabolism of GDP, compared to ALA or GLN, contributed to the superior performance of high-dose GDP in terms of blood availability of GLN.
Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.
da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho
2015-10-01
The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.
Kitzmann, JP; O’Gorman, D; Kin, T; Gruessner, AC; Senior, P; Imes, S; Gruessner, RW; Shapiro, AMJ; Papas, KK
2014-01-01
Human islet allotransplant (ITx) for the treatment of type 1 diabetes is in phase III clinical registration trials in the US and standard of care in several other countries. Current islet product release criteria include viability based on cell membrane integrity stains, glucose stimulated insulin release (GSIR), and islet equivalent (IE) dose based on counts. However, only a fraction of patients transplanted with islets that meet or exceed these release criteria become insulin independent following one transplant. Measurements of islet oxygen consumption rate (OCR) have been reported as highly predictive of transplant outcome in many models. In this paper we report on the assessment of clinical islet allograft preparations using islet oxygen consumption rate (OCR) dose (or viable IE dose) and current product release assays in a series of 13 first transplant recipients. The predictive capability of each assay was examined and successful graft function was defined as 100% insulin independence within 45 days post-transplant. Results showed that OCR dose was most predictive of CTO. IE dose was also highly predictive, while GSIR and membrane integrity stains were not. In conclusion, OCR dose can predict CTO with high specificity and sensitivity and is a useful tool for evaluating islet preparations prior to clinical ITx. PMID:25131089
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W.
2013-01-01
Context Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. Objective To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. Design, Setting, and Participants A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. Intervention The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. Main Outcome Measure The composite of HIV disease progression or death from any cause. Results The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96–1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11–1.87) vs standard-dose supplementation. Conclusion In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Trial Registration clinicaltrials.gov Identifier: NCT00383669 PMID:23073950
Priyadarshika, R C U; Crosbie, J C; Kumar, B; Rogers, P A W
2011-01-01
Objectives Microbeam radiotherapy (MRT) with wafers of microscopically narrow, synchrotron generated X-rays is being used for pre-clinical cancer trials in animal models. It has been shown that high dose MRT can be effective at destroying tumours in animal models, while causing unexpectedly little damage to normal tissue. The aim of this study was to use a dermatopathological scoring system to quantify and compare the acute biological response of normal mouse skin with microplanar and broad-beam (BB) radiation as a basis for biological dosimetry. Method The skin flaps of three groups of mice were irradiated with high entrance doses (200 Gy, 400 Gy and 800 Gy) of MRT and BB and low dose BB (11 Gy, 22 Gy and 44 Gy). The mice were culled at different time-points post-irradiation. Skin sections were evaluated histologically using the following parameters: epidermal cell death, nuclear enlargement, spongiosis, hair follicle damage and dermal inflammation. The fields of irradiation were identified by γH2AX-positive immunostaining. Results The acute radiation damage in skin from high dose MRT was significantly lower than from high dose BB and, importantly, similar to low dose BB. Conclusion The integrated MRT dose was more relevant than the peak or valley dose when comparing with BB fields. In MRT-treated skin, the apoptotic cells of epidermis and hair follicles were not confined to the microbeam paths. PMID:21849367
Kromann, Sofie; Kudirkiene, Egle; Li, Lili; Thoefner, Ida; Daldorph, Elisabeth; Christensen, Jens Peter; Meng, Hecheng; Olsen, Rikke Heidemann
2017-01-01
There is an urgent need for novel antibiotics as the current antibiotics are losing their value due to increased resistance among clinically important bacteria. Sertraline, an on-marked anti-depressive drug, has been shown to modify bacterial activity in vitro, including increasing the susceptibility of Escherichia coli to antibiotics. The aim of the present study was to investigate if the antimicrobial activity of sertraline could be documented under clinical settings, hereunder if sertraline could potentiate the effect of tetracycline in treatment of an experimentally induced ascending infection in poultry. A total of 40 chickens were divided in four groups of 10 chickens each. All chickens were challenged with 4x103 colony forming units (CFU) of a tetracycline resistant E. coli strain using a surgical infection model, and subsequently treated with either high-dose sertraline, tetracycline, a combination hereof or received no treatment. Seven days post challenge all birds were submitted to necropsy and scored pathologically for lesions. The average lesion scores were significantly higher (P<0.05) in the groups that were treated with high-dose sertraline or high-dose sertraline combined with tetracycline. In conclusion high-dose treatments (four times the maximum therapeutic dose for treating human depression) with sertraline as an adjuvant for treatment of antibiotic resistant E. coli infections exacerbate the pathological outcome of infection in chickens.
Kromann, Sofie; Kudirkiene, Egle; Li, Lili; Thoefner, Ida; Daldorph, Elisabeth; Christensen, Jens Peter; Meng, Hecheng
2017-01-01
There is an urgent need for novel antibiotics as the current antibiotics are losing their value due to increased resistance among clinically important bacteria. Sertraline, an on-marked anti-depressive drug, has been shown to modify bacterial activity in vitro, including increasing the susceptibility of Escherichia coli to antibiotics. The aim of the present study was to investigate if the antimicrobial activity of sertraline could be documented under clinical settings, hereunder if sertraline could potentiate the effect of tetracycline in treatment of an experimentally induced ascending infection in poultry. A total of 40 chickens were divided in four groups of 10 chickens each. All chickens were challenged with 4x103 colony forming units (CFU) of a tetracycline resistant E. coli strain using a surgical infection model, and subsequently treated with either high-dose sertraline, tetracycline, a combination hereof or received no treatment. Seven days post challenge all birds were submitted to necropsy and scored pathologically for lesions. The average lesion scores were significantly higher (P<0.05) in the groups that were treated with high-dose sertraline or high-dose sertraline combined with tetracycline. In conclusion high-dose treatments (four times the maximum therapeutic dose for treating human depression) with sertraline as an adjuvant for treatment of antibiotic resistant E. coli infections exacerbate the pathological outcome of infection in chickens. PMID:29020098
Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance
Liuzzi, Raffaele; Savino, Federica; D’Avino, Vittoria; Pugliese, Mariagabriella; Cella, Laura
2015-01-01
Background Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2–12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters. Methods LiF:Mg,Ti dosimeters (TLD-100) were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV) and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0–10 Gy in step of 2Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy. Results The TLD-100 dose-response curves were obtained. In the dose range of 0–10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05). Conclusions This study demonstrates that the TLD dose response, for doses ≤10Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided. PMID:26427065
Ibbott, Geoffrey S.; Hanson, W.F.; Martin, Elizabeth; Kuske, Robert R.; Arthur, Douglas; Rabinovitch, Rachel; White, Julia; Wilenzick, Raymond M.; Harris, Irene; Tailor, Ramesh C.
2007-01-01
Purpose RTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast carcinoma following breast conserving surgery. Low or high dose rate sources were allowed. Dose prescription and treatment evaluation were based on recommendations in ICRU Report 58, and included the parameters mean central dose (MCD), average peripheral dose, dose homogeneity index (DHI), and the dimensions of the low and high dose regions. Methods and Materials Three levels of quality assurance were implemented: (1) Credentialing of institutions was required prior to entering patients onto the study. (2) Rapid review of each treatment plan was conducted prior to treatment, and (3) Retrospective review was performed by the Radiological Physics Center in conjunction with the study chairman and RTOG dosimetry staff. Results Credentialing focused on the accuracy of dose calculation algorithm and compliance with protocol guidelines. Rapid review was designed to identify and correct deviations from the protocol prior to treatment. The retrospective review involved recalculation of dosimetry parameters and review of dose distributions to evaluate the treatment. Specifying both central and peripheral doses resulted in uniform dose distributions, with a mean dose homogeneity index of 0.83 ±0.06. Conclusions Vigorous quality assurance resulted in a high-quality study with few deviations; only 4 of 100 patients were judged as minor variations from protocol and no patient was judged a major deviation. This study should be considered a model for quality assurance of future trials. PMID:18035213
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Bin; Lyu, Qingwen; Ma, Jianhua
2016-04-15
Purpose: In computed tomography perfusion (CTP) imaging, an initial phase CT acquired with a high-dose protocol can be used to improve the image quality of later phase CT acquired with a low-dose protocol. For dynamic regions, signals in the later low-dose CT may not be completely recovered if the initial CT heavily regularizes the iterative reconstruction process. The authors propose a hybrid nonlocal means (hNLM) regularization model for iterative reconstruction of low-dose CTP to overcome the limitation of the conventional prior-image induced penalty. Methods: The hybrid penalty was constructed by combining the NLM of the initial phase high-dose CT inmore » the stationary region and later phase low-dose CT in the dynamic region. The stationary and dynamic regions were determined by the similarity between the initial high-dose scan and later low-dose scan. The similarity was defined as a Gaussian kernel-based distance between the patch-window of the same pixel in the two scans, and its measurement was then used to weigh the influence of the initial high-dose CT. For regions with high similarity (e.g., stationary region), initial high-dose CT played a dominant role for regularizing the solution. For regions with low similarity (e.g., dynamic region), the regularization relied on a low-dose scan itself. This new hNLM penalty was incorporated into the penalized weighted least-squares (PWLS) for CTP reconstruction. Digital and physical phantom studies were performed to evaluate the PWLS-hNLM algorithm. Results: Both phantom studies showed that the PWLS-hNLM algorithm is superior to the conventional prior-image induced penalty term without considering the signal changes within the dynamic region. In the dynamic region of the Catphan phantom, the reconstruction error measured by root mean square error was reduced by 42.9% in PWLS-hNLM reconstructed image. Conclusions: The PWLS-hNLM algorithm can effectively use the initial high-dose CT to reconstruct low-dose CTP in the stationary region while reducing its influence in the dynamic region.« less
Yang, Feng; Waters, Katrina M.; Miller, John H.; Gritsenko, Marina A.; Zhao, Rui; Du, Xiuxia; Livesay, Eric A.; Purvine, Samuel O.; Monroe, Matthew E.; Wang, Yingchun; Camp, David G.; Smith, Richard D.; Stenoien, David L.
2010-01-01
Background High doses of ionizing radiation result in biological damage; however, the precise relationships between long-term health effects, including cancer, and low-dose exposures remain poorly understood and are currently extrapolated using high-dose exposure data. Identifying the signaling pathways and individual proteins affected at the post-translational level by radiation should shed valuable insight into the molecular mechanisms that regulate dose-dependent responses to radiation. Principal Findings We have identified 7117 unique phosphopeptides (2566 phosphoproteins) from control and irradiated (2 and 50 cGy) primary human skin fibroblasts 1 h post-exposure. Semi-quantitative label-free analyses were performed to identify phosphopeptides that are apparently altered by radiation exposure. This screen identified phosphorylation sites on proteins with known roles in radiation responses including TP53BP1 as well as previously unidentified radiation-responsive proteins such as the candidate tumor suppressor SASH1. Bioinformatic analyses suggest that low and high doses of radiation affect both overlapping and unique biological processes and suggest a role for MAP kinase and protein kinase A (PKA) signaling in the radiation response as well as differential regulation of p53 networks at low and high doses of radiation. Conclusions Our results represent the most comprehensive analysis of the phosphoproteomes of human primary fibroblasts exposed to multiple doses of ionizing radiation published to date and provide a basis for the systems-level identification of biological processes, molecular pathways and individual proteins regulated in a dose dependent manner by ionizing radiation. Further study of these modified proteins and affected networks should help to define the molecular mechanisms that regulate biological responses to radiation at different radiation doses and elucidate the impact of low-dose radiation exposure on human health. PMID:21152398
Roumie, Christianne L; Arbogast, Patrick G; Mitchel, Edward F; Griffin, Marie R
2005-01-01
Objective To describe the use of coxibs outside of licensed indications and recommended dosing ranges including rofecoxib 50 mg, valdecoxib 20 to 40 mg, and celecoxib 400 mg. Design Cross-sectional study of coxib utilization in 2002 and 2003 and retrospective cohort analysis of new users. Participants Patients with known age and sex enrolled in Tennessee's Medicaid program. Measurements The prevalence of coxib use by dose and duration, and the proportion of persons initially prescribed a high-dose coxib and indications for such use. Results The estimated daily prevalence of nonaspirin prescription nonsteroidal anti-inflammatory drugs (NSAIDs) was 8.7% in 2002 to 2003 (45.7% coxibs). NSAID use peaked at age 65 to 74 with a prevalence of 19.8% (56.3% coxibs). Doses above the recommended daily dose for osteoarthritis accounted for 33.2% (95% confidence intervals [CIs] 32.4%, 33.9%) of celecoxib use, 14.9% (95% CI 14.4%, 15.5%) of rofecoxib use, and 52.2% (95% CI 50.6%, 53.8%) of valdecoxib use. Most of these prescriptions were for a month's supply. For new coxib users, 13.5% were given a month's supply for the highest dose category, and 28% refilled their prescriptions within 7 days of the end of the original prescription. Of these new chronic high-dose users, 17.2% had ischemic heart disease and 7.1% had heart failure. Conclusions A substantial portion of coxib prescriptions were for a month's supply at doses above those recommended for most chronic indications. New users were also prescribed high doses despite evidence for cardiovascular comorbidity. These prescribing patterns at doses outside licensed indications are both inappropriate and potentially dangerous. PMID:16191131
NASA Astrophysics Data System (ADS)
Smarda, M.; Alexopoulou, E.; Mazioti, A.; Kordolaimi, S.; Ploussi, A.; Priftis, K.; Efstathopoulos, E.
2015-09-01
Purpose of the study is to determine the appropriate iterative reconstruction (IR) algorithm level that combines image quality and diagnostic confidence, for pediatric patients undergoing high-resolution computed tomography (HRCT). During the last 2 years, a total number of 20 children up to 10 years old with a clinical presentation of chronic bronchitis underwent HRCT in our department's 64-detector row CT scanner using the iDose IR algorithm, with almost similar image settings (80kVp, 40-50 mAs). CT images were reconstructed with all iDose levels (level 1 to 7) as well as with filtered-back projection (FBP) algorithm. Subjective image quality was evaluated by 2 experienced radiologists in terms of image noise, sharpness, contrast and diagnostic acceptability using a 5-point scale (1=excellent image, 5=non-acceptable image). Artifacts existance was also pointed out. All mean scores from both radiologists corresponded to satisfactory image quality (score ≤3), even with the FBP algorithm use. Almost excellent (score <2) overall image quality was achieved with iDose levels 5 to 7, but oversmoothing artifacts appearing with iDose levels 6 and 7 affected the diagnostic confidence. In conclusion, the use of iDose level 5 enables almost excellent image quality without considerable artifacts affecting the diagnosis. Further evaluation is needed in order to draw more precise conclusions.
NASA Astrophysics Data System (ADS)
Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Fornace, Albert J.; Datta, Kamal
2017-05-01
Ionizing radiation (IR) is a recognized risk factor for colorectal cancer (CRC) and astronauts undertaking long duration space missions are expected to receive IR doses in excess of permissible limits with implications for colorectal carcinogenesis. Exposure to IR in outer space occurs at low doses and dose rates, and energetic heavy ions due to their high linear energy transfer (high-LET) characteristics remain a major concern for CRC risk in astronauts. Previously, we have demonstrated that intestinal tumorigenesis in a mouse model (APC1638N/+) of human colorectal cancer was significantly higher after exposure to high dose rate energetic heavy ions relative to low-LET γ radiation. The purpose of the current study was to compare intestinal tumorigenesis in APC1638N/+ mice after exposure to energetic heavy ions at high (50 cGy/min) and relatively low (0.33 cGy/min) dose rate. Male and female mice (6-8 weeks old) were exposed to either 10 or 50 cGy of 28Si (energy: 300 MeV/n; LET: 70 keV/μm) or 56Fe (energy: 1000 MeV/n; LET: 148 keV/μm) ions at NASA Space Radiation Laboratory in Brookhaven National Laboratory. Mice (n = 20 mice/group) were euthanized and intestinal and colon tumor frequency and size were counted 150 days after radiation exposure. Intestinal tumorigenesis in male mice exposed to 56Fe was similar for high and low dose rate exposures. Although male mice showed a decreasing trend at low dose rate relative to high dose rate exposures, the differences in tumor frequency between the two types of exposures were not statistically significant after 28Si radiation. In female mice, intestinal tumor frequency was similar for both radiation type and dose rates tested. In both male and female mice intestinal tumor size was not different after high and low dose rate radiation exposures. Colon tumor frequency in male and female mice after high and low dose rate energetic heavy ions was also not significantly different. In conclusion, intestinal and colonic tumor frequency and size was similar irrespective of energetic heavy ion radiation dose rate suggesting that carcinogenic potential of energetic heavy ions is independent of dose rate.
Beneficial effects of low dose Musa paradisiaca on the semen quality of male Wistar rats
Alabi, A. S.; Omotoso, Gabriel O.; Enaibe, B. U.; Akinola, O. B.; Tagoe, C. N. B.
2013-01-01
Background: This study aimed at determining the effects of administration of mature green fruits of Musa paradisiaca on the semen quality of adult male Wistar rats. Materials and Methods: The animals used for the study were grouped into three: the control group, given 2 ml of double distilled water, a low dose group given 500 mg/kg/day and a high dose group given 1000 mg/kg/day of the plantain fruits, which was made into flour, and dissolved in 2 ml of double distilled water for easy oral administration. Results: Significant increment in the semen parameters was noticed in animals that received a lower dose of the plantain flour, but those animals who received the high dose had marked and very significant reduction in sperm cell concentration and percentage of morphologically normal spermatozoa. Conclusion: Musa paradisiaca should be consumed in moderate quantities in order to derive its beneficial effects of enhancing male reproductive functions. PMID:23798793
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Reid F.; Zhai, Huifang; Both, Stefan
Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, andmore » IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.« less
Modh, Rishi; Cai, Peter Y; Sheffield, Alyssa; Yeung, Lawrence L
2015-01-01
Objective. To evaluate the recurrence rate of bulbar urethral strictures managed with cold knife direct vision internal urethrotomy and high dose corticosteroid injection. Methods. 28 patients with bulbar urethral strictures underwent direct vision internal urethrotomy with high dose triamcinolone injection into the periurethral tissue and were followed up for recurrence. Results. Our cohort had a mean age of 60 years and average stricture length of 1.85 cm, and 71% underwent multiple previous urethral stricture procedures with an average of 5.7 procedures each. Our technique modification of high dose corticosteroid injection had a recurrence rate of 29% at a mean follow-up of 20 months with a low rate of urinary tract infections. In patients who failed treatment, mean time to stricture recurrence was 7 months. Patients who were successfully treated had significantly better International Prostate Symptom Scores at 6, 9, and 12 months. There was no significant difference in maximum flow velocity on Uroflowmetry at last follow-up but there was significant difference in length of follow-up (p = 0.02). Conclusions. High dose corticosteroid injection at the time of direct vision internal urethrotomy is a safe and effective procedure to delay anatomical and symptomatic recurrence of bulbar urethral strictures, particularly in those who are poor candidates for urethroplasty.
Thai, Wai-ee; Wai, Bryan; Lin, Kaity; Cheng, Teresa; Heist, E. Kevin; Hoffmann, Udo; Singh, Jagmeet; Truong, Quynh A.
2012-01-01
Background Efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual source CT (DSCT) protocol, we aim to determine the radiation dose and image quality (IQ) in patients undergoing pulmonary vein (PV) imaging. Methods and Results In 94 patients (61±9 years, 71% male) who underwent 128-slice DSCT (pitch 3.4), radiation dose and IQ were assessed and compared between 69 patients in sinus rhythm (SR) and 25 in atrial fibrillation (AF). Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high-pitch. In a subset of 18 patients with prior magnetic resonance imaging (MRI) for PV assessment, PV anatomy and scan duration were compared to high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 [1.3, 1.9] mSv, with no difference between SR and AF (1.4 vs 1.5 mSv, p=0.22). No high-pitch CT scans were non-diagnostic or had poor IQ. Radiation dose was reduced with high-pitch (1.6 mSv) compared to standard protocols (19.3 mSv, p<0.0001). This radiation dose reduction was seen with SR (1.5 vs 16.7 mSv, p<0.0001) but was more profound with AF (1.9 vs 27.7 mSv, p=0.039). There was excellent agreement of PV anatomy (kappa 0.84, p<0.0001), and a shorter CT scan duration (6 minutes) compared to MRI (41 minutes, p<0.0001). Conclusions Using a high-pitch DSCT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent IQ in patients with SR or AF. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy. PMID:22586259
TH-A-9A-04: Incorporating Liver Functionality in Radiation Therapy Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, V; Epelman, M; Feng, M
2014-06-15
Purpose: Liver SBRT patients have both variable pretreatment liver function (e.g., due to degree of cirrhosis and/or prior treatments) and sensitivity to radiation, leading to high variability in potential liver toxicity with similar doses. This work aims to explicitly incorporate liver perfusion into treatment planning to redistribute dose to preserve well-functioning areas without compromising target coverage. Methods: Voxel-based liver perfusion, a measure of functionality, was computed from dynamic contrast-enhanced MRI. Two optimization models with different cost functions subject to the same dose constraints (e.g., minimum target EUD and maximum critical structure EUDs) were compared. The cost functions minimized were EUDmore » (standard model) and functionality-weighted EUD (functional model) to the liver. The resulting treatment plans delivering the same target EUD were compared with respect to their DVHs, their dose wash difference, the average dose delivered to voxels of a particular perfusion level, and change in number of high-/low-functioning voxels receiving a particular dose. Two-dimensional synthetic and three-dimensional clinical examples were studied. Results: The DVHs of all structures of plans from each model were comparable. In contrast, in plans obtained with the functional model, the average dose delivered to high-/low-functioning voxels was lower/higher than in plans obtained with its standard counterpart. The number of high-/low-functioning voxels receiving high/low dose was lower in the plans that considered perfusion in the cost function than in the plans that did not. Redistribution of dose can be observed in the dose wash differences. Conclusion: Liver perfusion can be used during treatment planning potentially to minimize the risk of toxicity during liver SBRT, resulting in better global liver function. The functional model redistributes dose in the standard model from higher to lower functioning voxels, while achieving the same target EUD and satisfying dose limits to critical structures. This project is funded by MCubed and grant R01-CA132834.« less
Dose of Prophylactic Platelet Transfusions and Prevention of Hemorrhage
Slichter, Sherrill J.; Kaufman, Richard M.; Assmann, Susan F.; McCullough, Jeffrey; Triulzi, Darrell J.; Strauss, Ronald G.; Gernsheimer, Terry B.; Ness, Paul M.; Brecher, Mark E.; Josephson, Cassandra D.; Konkle, Barbara A.; Woodson, Robert D.; Ortel, Thomas L.; Hillyer, Christopher D.; Skerrett, Donna L.; McCrae, Keith R.; Sloan, Steven R.; Uhl, Lynne; George, James N.; Aquino, Victor M.; Manno, Catherine S.; McFarland, Janice G.; Hess, John R.; Leissinger, Cindy; Granger, Suzanne
2010-01-01
BACKGROUND We conducted a trial of prophylactic platelet transfusions to evaluate the effect of platelet dose on bleeding in patients with hypoproliferative thrombocytopenia. METHODS We randomly assigned hospitalized patients undergoing hematopoietic stem-cell transplantation or chemotherapy for hematologic cancers or solid tumors to receive prophylactic platelet transfusions at a low dose, a medium dose, or a high dose (1.1×1011, 2.2×1011, or 4.4×1011 platelets per square meter of body-surface area, respectively), when morning platelet counts were 10,000 per cubic millimeter or lower. Clinical signs of bleeding were assessed daily. The primary end point was bleeding of grade 2 or higher (as defined on the basis of World Health Organization criteria). RESULTS In the 1272 patients who received at least one platelet transfusion, the primary end point was observed in 71%, 69%, and 70% of the patients in the low-dose group, the medium-dose group, and the high-dose group, respectively (differences were not significant). The incidences of higher grades of bleeding, and other adverse events, were similar among the three groups. The median number of platelets transfused was significantly lower in the low-dose group (9.25×1011) than in the medium-dose group (11.25×1011) or the high-dose group (19.63×1011) (P = 0.002 for low vs. medium, P<0.001 for high vs. low and high vs. medium), but the median number of platelet transfusions given was significantly higher in the low-dose group (five, vs. three in the medium-dose and three in the high-dose group; P<0.001 for low vs. medium and low vs. high). Bleeding occurred on 25% of the study days on which morning platelet counts were 5000 per cubic millimeter or lower, as compared with 17% of study days on which platelet counts were 6000 to 80,000 per cubic millimeter (P<0.001). CONCLUSIONS Low doses of platelets administered as a prophylactic transfusion led to a decreased number of platelets transfused per patient but an increased number of transfusions given. At doses between 1.1×1011 and 4.4×1011 platelets per square meter, the number of platelets in the prophylactic transfusion had no effect on the incidence of bleeding. (ClinicalTrials.gov number, NCT00128713.) PMID:20164484
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauss, Daniel, E-mail: dkrauss@beaumont.edu; Kestin, Larry; Ye, Hong
2011-07-15
Purpose: Assessment of androgen deprivation therapy (ADT) benefits for prostate cancer treated with dose-escalated radiotherapy (RT). Methods and Materials: From 1991 to 2004, 1,044 patients with intermediate- (n = 782) or high-risk (n = 262) prostate cancer were treated with dose-escalated RT at William Beaumont Hospital. Patients received external-beam RT (EBRT) alone, brachytherapy (high or low dose rate), or high dose rate brachytherapy plus pelvic EBRT. Intermediate-risk patients had Gleason score 7, prostate-specific antigen (PSA) 10.0-19.9 ng/mL, or Stage T2b-T2c. High-risk patients had Gleason score 8-10, PSA {>=}20, or Stage T3. Patients were additionally divided specifically by Gleason score, presencemore » of palpable disease, and PSA level to further define subgroups benefitting from ADT. Results: Median follow-up was 5 years; 420 patients received ADT + dose-escalated RT, and 624 received dose-escalated RT alone. For all patients, no advantages in any clinical endpoints at 8 years were associated with ADT administration. No differences in any endpoints were associated with ADT administration based on intermediate- vs. high-risk group or RT modality when analyzed separately. Patients with palpable disease plus Gleason {>=}8 demonstrated improved clinical failure rates and a trend toward improved survival with ADT. Intermediate-risk patients treated with brachytherapy alone had improved biochemical control when ADT was given. Conclusion: Benefits of ADT in the setting of dose-escalated RT remain poorly defined. This question must continue to be addressed in prospective study.« less
Tardy, Claudine; Goffinet, Marine; Boubekeur, Nadia; Cholez, Guy; Ackermann, Rose; Sy, Gavin; Keyserling, Constance; Lalwani, Narendra; Paolini, John F.; Dasseux, Jean-Louis; Barbaras, Ronald; Baron, Rudi
2015-01-01
Objective CER-001 is a novel engineered HDL-mimetic comprised of recombinant human apoA-I and charged phospholipids that was designed to mimic the beneficial properties of nascent pre-ß HDL. In this study, we have evaluated the dose-dependent regulation of ABCA1 expression in vitro and in vivo in the presence of CER-001 and native HDL (HDL3). Methods and Results CER-001 induced cholesterol efflux from J774 macrophages in a dose-dependent manner similar to natural HDL. A strong down-regulation of the ATP-binding cassette A1 (ABCA1) transporter mRNA (- 50%) as well as the ABCA1 membrane protein expression (- 50%) was observed at higher doses of CER-001 and HDL3 compared to non-lipidated apoA-I. In vivo, in an apoE-/- mouse “flow cessation model,” in which the left carotid artery was ligatured to induce local inflammation, the inhibition of atherosclerotic plaque burden progression in response to a dose-range of every-other-day CER-001 or HDL in the presence of a high-fat diet for two weeks was assessed. We observed a U-shaped dose-response curve: inhibition of the plaque total cholesterol content increased with increasing doses of CER-001 or HDL3 up to a maximum inhibition (- 51%) at 5 mg/kg; however, as the dose was increased above this threshold, a progressively less pronounced inhibition of progression was observed, reaching a complete absence of inhibition of progression at doses of 20 mg/kg and over. ABCA1 protein expression in the same atherosclerotic plaque was decreased by-45% and-68% at 50 mg/kg for CER-001 and HDL respectively. Conversely, a-12% and 0% decrease in ABCA1 protein expression was observed at the 5 mg/kg dose for CER-001 and HDL respectively. Conclusions These data demonstrate that high doses of HDL and CER-001 are less effective at slowing progression of atherosclerotic plaque in apoE-/- mice compared to lower doses, following a U-shaped dose-response curve. A potential mechanism for this phenomenon is supported by the observation that high doses of HDL and CER-001 induce a rapid and strong down-regulation of ABCA1 both in vitro and in vivo. In conclusion, maximally efficient HDL- or CER-001-mediated cholesterol removal from atherosclerotic plaque is achieved by maximizing macrophage-mediated efflux from the plaque while minimizing dose-dependent down-regulation of ABCA1 expression. These observations may help define the optimal dose of HDL mimetics for testing in clinical trials of atherosclerotic burden regression. PMID:26335690
High-dose MVCT image guidance for stereotactic body radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westerly, David C.; Schefter, Tracey E.; Kavanagh, Brian D.
Purpose: Stereotactic body radiation therapy (SBRT) is a potent treatment for early stage primary and limited metastatic disease. Accurate tumor localization is essential to administer SBRT safely and effectively. Tomotherapy combines helical IMRT with onboard megavoltage CT (MVCT) imaging and is well suited for SBRT; however, MVCT results in reduced soft tissue contrast and increased image noise compared with kilovoltage CT. The goal of this work was to investigate the use of increased imaging doses on a clinical tomotherapy machine to improve image quality for SBRT image guidance. Methods: Two nonstandard, high-dose imaging modes were created on a tomotherapy machinemore » by increasing the linear accelerator (LINAC) pulse rate from the nominal setting of 80 Hz, to 160 Hz and 300 Hz, respectively. Weighted CT dose indexes (wCTDIs) were measured for the standard, medium, and high-dose modes in a 30 cm solid water phantom using a calibrated A1SL ion chamber. Image quality was assessed from scans of a customized image quality phantom. Metrics evaluated include: contrast-to-noise ratios (CNRs), high-contrast spatial resolution, image uniformity, and percent image noise. In addition, two patients receiving SBRT were localized using high-dose MVCT scans. Raw detector data collected after each scan were used to reconstruct standard-dose images for comparison. Results: MVCT scans acquired using a pitch of 1.0 resulted in wCTDI values of 2.2, 4.7, and 8.5 cGy for the standard, medium, and high-dose modes respectively. CNR values for both low and high-contrast materials were found to increase with the square root of dose. Axial high-contrast spatial resolution was comparable for all imaging modes at 0.5 lp/mm. Image uniformity was improved and percent noise decreased as the imaging dose increased. Similar improvements in image quality were observed in patient images, with decreases in image noise being the most notable. Conclusions: High-dose imaging modes are made possible on a clinical tomotherapy machine by increasing the LINAC pulse rate. Increasing the imaging dose results in increased CNRs; making it easier to distinguish the boundaries of low contrast objects. The imaging dose levels observed in this work are considered acceptable at our institution for SBRT treatments delivered in 3-5 fractions.« less
Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer
NASA Astrophysics Data System (ADS)
Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.
2017-09-01
One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.
TU-EF-304-09: Quantifying the Biological Effects of Therapeutic Protons by LET Spectrum Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guan, F; Bronk, L; Kerr, M
2015-06-15
Purpose: To correlate in vitro cell kill with linear energy transfer (LET) spectra using Monte Carlo simulations and knowledge obtained from previous high-throughput in vitro proton relative biological effectiveness (RBE) measurements. Methods: The Monte Carlo simulation toolkit Geant4 was used to design the experimental setups and perform the dose, dose-averaged LET, and LET spectra calculations. The clonogenic assay was performed using the H460 lung cancer cell line in standard 6-well plates. Using two different experimental setups, the same dose and dose-averaged LET (12.6 keV/µm) was delivered to the cell layer; however, each respective energy or LET spectrum was different. Wemore » quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous RBE measurements) events in the LET spectra separately for these two setups as 39% and 53%. 8 dose levels with 1 Gy increments were delivered. The photon reference irradiation was performed using 6 MV x-rays from a LINAC. Results: The survival curves showed that both proton irradiations demonstrated an increased RBE compared to the reference photon irradiation. Within the proton-irradiated cells, the setup with 53% dose contribution from high-LET events exhibited the higher biological effectiveness. Conclusion: The experimental results indicate that the dose-averaged LET may not be an appropriate indicator to quantify the biological effects of protons when the LET spectrum is broad enough to contain both low- and high-LET events. Incorporating the LET spectrum distribution into robust intensity-modulated proton therapy optimization planning may provide more accurate biological dose distribution than using the dose-averaged LET. NIH Program Project Grant 2U19CA021239-35.« less
Ketelsen, Dominik; Buchgeister, Markus; Korn, Andreas; Fenchel, Michael; Schmidt, Bernhard; Flohr, Thomas G; Thomas, Christoph; Schabel, Christoph; Tsiflikas, Ilias; Syha, Roland; Claussen, Claus D; Heuschmid, Martin
2012-01-01
Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medical Solutions, Germany). The following scan parameters were used: 320 mAs per rotation, 100 and 120 kV, pitch 3.4 for prospectively ECG-triggered high-pitch CTCA, scan range of 13.5 cm, collimation 64 × 2 × 0.6 mm with z-flying focal spot, gantry rotation time 280 ms, and simulated heart rate of 60 beats per minute. Results. Depending on the applied tube potential, the effective whole-body dose of the cardiac scan ranged from 1.1 mSv to 1.6 mSv and from 1.2 to 1.8 mSv for males and females, respectively. The radiosensitive breast tissue in the range of the primary beam caused an increased female-specific effective dose of 8.6%±0.3% compared to males. Decreasing the tube potential, a significant reduction of the effective dose of 35.8% and 36.0% can be achieved for males and females, respectively (P < 0.001). Conclusion. The radiologist and the CT technician should be aware of this new dose-saving strategy to keep the radiation exposure as low as reasonablly achievable.
Optically Stimulated Luminescent Dosimetry for High Dose Rate Brachytherapy
Tien, Christopher Jason; Ebeling, Robert; Hiatt, Jessica R.; Curran, Bruce; Sternick, Edward
2012-01-01
Purpose: The objective was to determine whether optically stimulated luminescent dosimeters (OSLDs) were appropriate for in vivo measurements in high dose rate brachytherapy. In order to make this distinction, three dosimetric characteristics were tested: dose linearity, dose rate dependence, and angular dependence. The Landauer nanoDot™ OSLDs were chosen due to their popularity and their availability commercially. Methods: To test the dose linearity, each OSLD was placed at a constant location and the dwell time was varied. Next, in order to test the dose rate dependence, each OSLD was placed at different OLSD-to-source distances and the dwell time was held constant. A curved geometry was created using a circular Accuboost® applicator in order to test angular dependence. Results: The OSLD response remained linear for high doses and was independent of dose rate. For doses up to 600 cGy, the linear coefficient of determination was 0.9988 with a response of 725 counts per cGy. The angular dependence was significant only in “edge-on” scenarios. Conclusion: OSLDs are conveniently read out using commercially available readers. OSLDs can be re-read and serve as a permanent record for clinical records or be annealed using conventional fluorescent light. Lastly, OSLDs are produced commercially for $5 each. Due to these convenient features, in conjunction with the dosimetric performance, OSLDs should be considered a clinically feasible and attractive tool for in vivo HDR brachytherapy measurements. PMID:22888476
Winter, Harland S.; Krzeski, Piotr; Heyman, Melvin B.; Ibarguen-Secchia, Eduardo; Iwanczak, Barbara; Kaczmarski, Maciej; Kierkus, Jaroslaw; Kolaček, Sanja; Osuntokun, Bankole; Quiros, J. Antonio; Shah, Manoj; Yacyshyn, Bruce; Dunnmon, Preston M.
2014-01-01
ABSTRACT Objective: The aim of the study was to assess the safety and efficacy of high- and low-dose oral, delayed-release mesalamine in a randomized, double-blind, active control study of children with mild-to-moderately active ulcerative colitis. Methods: Patients ages 5 to 17 years, with a Pediatric Ulcerative Colitis Activity Index (PUCAI) score of ≥10 to ≤55 and a truncated Mayo Score of ≥1 for both rectal bleeding and stool frequency, were enrolled. They received body weight–dependent doses of oral, delayed-release mesalamine for 6 weeks in a low- (27–71 mg · g−1 · day−1) or high-dose group (53–118 mg · g−1 · day−1). The primary endpoint was treatment success, defined as the proportion of patients who achieved remission (PUCAI score <10) or partial response (PUCAI score ≥10 with a decrease from baseline by ≥20 points). Secondary endpoints included truncated Mayo Score and global assessment of change of disease activity. Results: The modified intent-to-treat population included 81 of 83 patients enrolled. Treatment success by PUCAI was achieved by 23 of 41 (56%) and 22 of 40 (55%) patients in the mesalamine low- and high-dose groups, respectively (P = 0.924). Truncated Mayo Score (low-dose 30 [73%] and high-dose 28 [70%] patients) and other efficacy results did not differ between the groups. The type and severity of adverse events were consistent with those reported in previous studies of adults with ulcerative colitis and did not differ between groups. Conclusions: Both low- and high-dose oral, delayed-release mesalamine doses were equally effective as short-term treatment of mild-to-moderately active ulcerative colitis in children, without a specific benefit or risk to using either dose. PMID:25419597
Foo, Jasmine; Chmielecki, Juliann; Pao, William; Michor, Franziska
2013-01-01
Introduction Erlotinib (Tarceva) is an epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor, which effectively targets EGFR-mutant driven non–small-cell lung cancer. However, the evolution of acquired resistance because of a second-site mutation (T790M) within EGFR remains an obstacle to successful treatment. Methods We used mathematical modeling and available clinical trial data to predict how different pharmacokinetic parameters (fast versus slow metabolism) and dosing schedules (low dose versus high dose; missed doses with and without make-up doses) might affect the evolution of T790M-mediated resistance in mixed populations of tumor cells. Results We found that high-dose pulses with low-dose continuous therapy impede the development of resistance to the maximum extent, both pre- and post-emergence of resistance. The probability of resistance is greater in fast versus slow drug metabolizers, suggesting a potential mechanism, unappreciated to date, influencing acquired resistance in patients. In case of required dose modifications because of toxicity, little difference is observed in terms of efficacy and resistance dynamics between the standard daily dose (150 mg/d) and 150 mg/d alternating with 100 mg/d. Missed doses are expected to lead to resistance faster, even if make-up doses are attempted. Conclusions For existing and new kinase inhibitors, this novel framework can be used to rationally and rapidly design optimal dosing strategies to minimize the development of acquired resistance. PMID:22982659
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunault, Claudine C., E-mail: claudine.hunault@rivm.n; Eijkeren, Jan C.H. van; Mensinga, Tjeert T.
Introduction: No model exists to describe the disposition and kinetics of inhaled cannabis containing a high THC dose. We aimed to develop a kinetic model providing estimates of the THC serum concentrations after smoking cannabis cigarettes containing high THC doses (up to 69 mg THC). Methods: Twenty-four male non-daily cannabis users smoked cannabis cigarettes containing 29.3 mg, 49.1 mg, and 69.4 mg THC. Blood samples were collected over a period of 0-8 h and serum THC concentrations were measured. A two-compartment open model was fitted on the individual observed data. Results: Large inter-individual variability was observed in the pharmacokinetic parameters.more » The median pharmacokinetic parameters generated by the model were C{sub max} = 175 ng/mL, T{sub max} = 14 min, and AUC{sub 0-8h} = 8150 ng x min/mL for the 69.4 mg THC dose. Median model results show an almost linear dose response relation for C{sub max}/Dose = 2.8 x 10{sup -6}/mL and AUC{sub 0-8h}/Dose = 136 x 10{sup -6} min/mL. However, for increasing dose level, there was a clear decreasing trend: C{sub max}/Dose = 3.4, 2.6 and 2.5 x 10{sup -6}/mL and AUC{sub 0-8h}/Dose = 157, 133 and 117 x 10{sup -6} min/mL for the 29.3, 49.1 and 69.4 mg dose, respectively. Within the restriction of 8 h of observation, the apparent terminal half life of THC was 150 min. Conclusion: The model offers insight into the pharmacokinetics of THC in recreational cannabis users smoking cannabis containing high doses of THC mixed with tobacco. The model is an objective method for providing serum THC concentrations up to 8 h after smoking cannabis with a high THC content (up to 23%).« less
Giuntini, Serena; Beernink, Peter T; Granoff, Dan M
2015-12-16
FHbp is a major serogroup B meningococcal vaccine antigen. Binding of complement Factor H (FH) to FHbp is specific for human and some non-human primate FH. In previous studies, FH binding to FHbp vaccines impaired protective anti-FHbp antibody responses. In this study we investigated anti-FHbp antibody responses to a third dose of a licensed serogroup B vaccine (MenB-4C) in infant macaques vaccinated in a previous study with MenB-4C. Six macaques with high binding of FH to FHbp (FH(high)), and six with FH(low) baseline phenotypes, were immunized three months after dose 2. After dose 2, macaques with the FH(low) baseline phenotype had serum anti-FHbp antibodies that enhanced FH binding to FHbp (functionally converting them to a FH(high) phenotype). In this group, activation of the classical complement pathway (C4b deposition) by serum anti-FHbp antibody, and anti-FHbp serum bactericidal titers were lower after dose 3 than after dose 2 (p<0.02). In macaques with the FH(high) baseline phenotype, the respective anti-FHbp C4b deposition and bactericidal titers were similar after doses 2 and 3. Two macaques developed serum anti-FH autoantibodies after dose 2, which were not detected after dose 3. In conclusion, in macaques with the FH(low) baseline phenotype whose post-dose 2 serum anti-FHbp antibodies had converted them to FH(high), the anti-FHbp antibody repertoire to dose 3 was skewed to less protective epitopes than after dose 2. Mutant FHbp vaccines that eliminate FH binding may avoid eliciting anti-FHbp antibodies that enhance FH binding, and confer greater protection with less risk of inducing anti-FH autoantibodies than FHbp vaccines that bind FH. Copyright © 2015 Elsevier Ltd. All rights reserved.
Eaton, John E.; Silveira, Marina G.; Pardi, Darrell S.; Sinakos, Emmanouil; Kowdley, Kris V.; Luketic, Velimir A.C.; Harrison, M. Edwyn; McCashland, Timothy; Befeler, Alex S.; Harnois, Denise; Jorgensen, Roberta; Petz, Jan; Lindor, Keith D.
2011-01-01
OBJECTIVES Some studies have suggested that ursodeoxycholic acid (UDCA) may have a chemopreventive effect on the development of colorectal neoplasia in patients with ulcerative colitis (UC) and primary sclerosing cholangitis (PSC). We examined the effects of high-dose (28–30 mg/kg/day) UDCA on the development of colorectal neoplasia in patients with UC and PSC. METHODS Patients with UC and PSC enrolled in a prior, multicenter randomized placebo-controlled trial of high-dose UDCA were evaluated for the development of colorectal neoplasia. Patients with UC and PSC who received UDCA were compared with those who received placebo. We reviewed the pathology and colonoscopy reports for the development of low-grade or high-grade dysplasia or colorectal cancer. RESULTS Fifty-six subjects were followed for a total of 235 patient years. Baseline characteristics (including duration of PSC and UC, medications, patient age, family history of colorectal cancer, and smoking status) were similar for both the groups. Patients who received high-dose UDCA had a significantly higher risk of developing colorectal neoplasia (dysplasia and cancer) during the study compared with those who received placebo (hazard ratio: 4.44, 95% confidence interval: 1.30–20.10, P=0.02). CONCLUSIONS Long-term use of high-dose UDCA is associated with an increased risk of colorectal neoplasia in patients with UC and PSC. PMID:21556038
Sanchez-Migallon Guzman, David; KuKanich, Butch; Drazenovich, Tracy L.; Olsen, Glenn H.; Paul-Murphy, Joanne R.
2014-01-01
Conclusion and Clinical Relevance—Results indicated hydromorphone hydrochloride had high bioavailability and rapid elimination after IM administration, with a short terminal half-life, rapid plasma clearance, and large volume of distribution in American kestrels. Further studies regarding the effects of other doses, other administration routes, constantrate infusions, and slow release formulations on the pharmacokinetics of hydromorphone hydrochloride and its metabolites in American kestrels may be indicated.
Udani, Jay K.; Brown, Donald J.; Tan, Maria Olivia C.; Hardy, Mary
2013-01-01
Objective 7-Hydroxymaitairesinol (7-HMR) is a naturally occurring plant lignan found in whole grains and the Norway spruce (Piciea abies). The purpose of this study was to evaluate the bioavailability of a proprietary 7-HMR product (HMRlignan, Linnea SA, Locarno, Switzerland) through measurement of lignan metabolites and metabolic precursors. Methods A single-blind, parallel, pharmacokinetic and dose-comparison study was conducted on 22 post-menopausal females not receiving hormone replacement therapy. Subjects were enrolled in either a 36 mg/d (low-dose) or 72 mg/d dose (high-dose) regimen for 8 weeks. Primary measured outcomes included plasma levels of 7-HMR and enterolactone (ENL), and single-dose pharmacokinetic analysis was performed on a subset of subjects in the low-dose group. Safety data and adverse event reports were collected as well as data on hot flash frequency and severity. Results Pharmacokinetic studies demonstrated 7-HMR Cmax = 757.08 ng/ml at 1 hour and ENL Cmax = 4.8 ng/ml at 24 hours. From baseline to week 8, plasma 7-HMR levels increased by 191% in the low-dose group (p < 0.01) and by 1238% in the high-dose group (p < 0.05). Plasma ENL levels consistently increased as much as 157% from baseline in the low-dose group and 137% in the high-dose group. Additionally, the mean number of weekly hot flashes decreased by 50%, from 28.0/week to 14.3/week (p < 0.05) in the high-dose group. No significant safety issues were identified in this study. Conclusion The results demonstrate that HMRlignan is quickly absorbed into the plasma and is metabolized to ENL in healthy postmenopausal women. Clinically, the data demonstrate a statistically significant improvement in hot flash frequency. Doses up to 72 mg/d HMRlignan for 8 weeks were safe and well tolerated in this population. PMID:24606716
Fernandez-Palomo, Cristian; Mothersill, Carmel; Bräuer-Krisch, Elke; Laissue, Jean; Seymour, Colin; Schültke, Elisabeth
2015-01-01
Objective Synchrotron radiation has shown high therapeutic potential in small animal models of malignant brain tumours. However, more studies are needed to understand the radiobiological effects caused by the delivery of high doses of spatially fractionated x-rays in tissue. The purpose of this study was to explore the use of the γ-H2AX antibody as a marker for dose deposition in the brain of rats after synchrotron microbeam radiation therapy (MRT). Methods Normal and tumour-bearing Wistar rats were exposed to 35, 70 or 350 Gy of MRT to their right cerebral hemisphere. The brains were extracted either at 4 or 8 hours after irradiation and immediately placed in formalin. Sections of paraffin-embedded tissue were incubated with anti γ-H2AX primary antibody. Results While the presence of the C6 glioma does not seem to modulate the formation of γ-H2AX in normal tissue, the irradiation dose and the recovery versus time are the most important factors affecting the development of γ-H2AX foci. Our results also suggest that doses of 350 Gy can trigger the release of bystander signals that significantly amplify the DNA damage caused by radiation and that the γ-H2AX biomarker does not only represent DNA damage produced by radiation, but also damage caused by bystander effects. Conclusion In conclusion, we suggest that the γ-H2AX foci should be used as biomarker for targeted and non-targeted DNA damage after synchrotron radiation rather than a tool to measure the actual physical doses. PMID:25799425
Kowal, Mikael A; van Steenbergen, Henk; Colzato, Lorenza S; Hazekamp, Arno; van der Wee, Nic J A; Manai, Meriem; Durieux, Jeffrey; Hommel, Bernhard
2015-11-01
Cannabis has been suggested to impair the capacity to recognize discrepancies between expected and executed actions. However, there is a lack of conclusive evidence regarding the acute impact of cannabis on the neural correlates of error monitoring. In order to contribute to the available knowledge, we used a randomized, double-blind, between-groups design to investigate the impact of administration of a low (5.5 mg THC) or high (22 mg THC) dose of vaporized cannabis vs. placebo on the amplitudes of the error-related negativity (ERN) and error positivity (Pe) in the context of the Flanker task, in a group of frequent cannabis users (required to use cannabis minimally 4 times a week, for at least 2 years). Subjects in the high dose group (n=18) demonstrated a significantly diminished ERN in comparison to the placebo condition (n=19), whereas a reduced Pe amplitude was observed in both the high and low dose (n=18) conditions, as compared to placebo. The results suggest that a high dose of cannabis may affect the neural correlates of both the conscious (late), as well as the initial automatic processes involved in error monitoring, while a low dose of cannabis might impact only the conscious (late) processing of errors. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.
Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-01-01
Introduction Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. Materials and Methods A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Results Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13–53.8% reduction in low dose protocol. Conclusion The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose. PMID:27437322
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, L; Shen, C; Wang, J
Purpose: To reduce cone beam CT (CBCT) imaging dose, we previously proposed a progressive dose control (PDC) scheme to employ temporal correlation between CBCT images at different fractions for image quality enhancement. A temporal non-local means (TNLM) method was developed to enhance quality of a new low-dose CBCT using existing high-quality CBCT. To enhance a voxel value, the TNLM method searches for similar voxels in a window. Due to patient deformation among the two CBCTs, a large searching window was required, reducing image quality and computational efficiency. This abstract proposes a deformation-assisted TNLM (DA-TNLM) method to solve this problem. Methods:more » For a low-dose CBCT to be enhanced using a high-quality CBCT, we first performed deformable image registration between the low-dose CBCT and the high-quality CBCT to approximately establish voxel correspondence between the two. A searching window for a voxel was then set based on the deformation vector field. Specifically, the search window for each voxel was shifted by the deformation vector. A TNLM step was then applied using only voxels within this determined window to correct image intensity at the low-dose CBCT. Results: We have tested the proposed scheme on simulated CIRS phantom data and real patient data. The CITS phantom was scanned on Varian onboard imaging CBCT system with coach shifting and dose reducing for each time. The real patient data was acquired in four fractions with dose reduced from standard CBCT dose to 12.5% of standard dose. It was found that the DA-TNLM method can reduce total dose by over 75% on average in the first four fractions. Conclusion: We have developed a PDC scheme which can enhance the quality of image scanned at low dose using a DA-TNLM method. Tests in phantom and patient studies demonstrated promising results.« less
Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2011-01-01
Purpose The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. Material and methods For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. Results HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. Conclusions HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning. PMID:27853479
Wang, Le; Peng, Pingan; Zhang, Ou; Xu, Xiaohan; Yang, Shiwei; Zhao, Yingxin; Zhou, Yujie
2014-01-01
Background Evidence suggests that high-dose statin pretreatment may reduce the risk of periprocedural myocardial infarction (PMI) and major adverse cardiac events (MACE) for certain patients; however, previous analyses have not considered patients with a history of statin maintenance treatment. In this meta-analysis of randomized controlled trials (RCTs), we reevaluated the efficacy of short-term high-dose statin pretreatment to prevent PMI and MACE in an expanded set of patients undergoing elective percutaneous coronary intervention. Methods We searched the PubMed/Medline database for RCTs that compared high-dose statin pretreatment with no statin or low-dose statin pretreatment as a prevention of PMI and MACE. We evaluated the incidence of PMI and MACE, including death, spontaneous myocardial infarction, and target vessel revascularization at the longest follow-up for each study for subgroups stratified by disease classification and prior low-dose statin treatment. Results Twenty-four RCTs with a total of 5,526 patients were identified. High-dose statin pretreatment was associated with 59% relative reduction in PMI (odds ratio [OR]: 0.41; 95% confidence interval [CI]: 0.34–0.49; P<0.00001) and 39% relative reduction in MACE (OR: 0.61; 95% CI: 0.45–0.83; P = 0.002). The benefit of high-dose statin pretreatment on MACE was significant for statin-naive patients (OR: 0.69; 95% CI: 0.50–0.95; P = 0.02) and prior low dose statin-treated patients (OR: 0.28; 95% CI: 0.12–0.65; P = 0.003); and for patients with acute coronary syndrome (OR: 0.52; 95% CI: 0.34–0.79; P = 0.003), but not for patients with stable angina (OR: 0.71; 95% CI 0.45–1.10; P = 0.12). Long-term effects on survival were less obvious. Conclusions High-dose statin pretreatment can result in a significant reduction in PMI and MACE for patients undergoing elective PCI. The positive effect of high-dose statin pretreatment on PMI and MACE is significant for statin-naïve patients and patients with prior treatment. The positive effect of high-dose statin pretreatment on MACE is significant for patients with acute coronary syndrome. PMID:25473831
Methylphenidate Exerts Dose-Dependent Effects on Glutamate Receptors and Behaviors
Cheng, Jia; Xiong, Zhe; Duffney, Lara J.; Wei, Jing; Liu, Aiyi; Liu, Sihang; Chen, Guo-Jun; Yan, Zhen
2014-01-01
Background Methylphenidate (MPH), a psychostimulant drug for the treatment of attention-deficit hyperactivity disorder (ADHD), produces the effects of increasing alertness and improving attention, while its misuse has been associated with an increased risk of aggression and psychosis. In this study, we sought to determine the molecular mechanism underlying the complex actions of MPH. Methods Adolescent (4-week-old) rats were given one injection of MPH at different doses. The impact of MPH on glutamatergic signaling in pyramidal neurons of prefrontal cortex (PFC) was measured. MPH-induced behavioral changes were also examined in parallel. Results We found that administration of low-dose (0.5 mg/kg) MPH selectively potentiated NMDAR-mediated excitatory synaptic currents (EPSCs) via adrenergic receptor activation, while the high-dose (10 mg/kg) MPH suppressed both NMDAR- and AMPAR-EPSCs. The dual effects of MPH on EPSCs were associated with bi-directional changes in the surface level of glutamate receptor subunits. Behavioral tests also indicated that low-dose MPH facilitated the PFC-mediated temporal order recognition memory (TORM) and attention, while animals injected with high-dose MPH exhibited significantly elevated locomotive activity. Inhibiting the function of SNAP-25, a key SNARE proteins involved in NMDAR exocytosis, blocked the increase of NMDAR-EPSC by low-dose MPH. In animals exposed to repeated stress, administration of low-dose MPH effectively restored NMDAR function and TORM via a mechanism dependent on SNAP-25. Conclusions Our results have provided a potential mechanism underlying the cognitive enhancing effects of low-dose MPH, as well as the psychosis-inducing effects of high-dose MPH. PMID:24832867
Effects of Alcohol on Performance on a Distraction Task During Simulated Driving
Allen, Allyssa J.; Meda, Shashwath A.; Skudlarski, Pawel; Calhoun, Vince; Astur, Robert; Ruopp, Kathryn C.; Pearlson, Godfrey D.
2009-01-01
Background Prior studies report that accidents involving intoxicated drivers are more likely to occur during performance of secondary tasks. We studied this phenomenon, using a dual-task paradigm, involving performance of a visual oddball (VO) task while driving in an alcohol challenge paradigm. Previous functional MRI (fMRI) studies of the VO task have shown activation in the anterior cingulate, hippocampus, and prefrontal cortex. Thus, we predicted dose-dependent decreases in activation of these areas during VO performance. Methods Forty healthy social drinkers were administered 3 different doses of alcohol, individually tailored to their gender and weight. Participants performed a VO task while operating a virtual reality driving simulator in a 3T fMRI scanner. Results Analysis showed a dose-dependent linear decrease in Blood Oxygen Level Dependent activation during task performance, primarily in hippocampus, anterior cingulate, and dorsolateral prefrontal areas, with the least activation occurring during the high dose. Behavioral analysis showed a dose-dependent linear increase in reaction time, with no effects associated with either correct hits or false alarms. In all dose conditions, driving speed decreased significantly after a VO stimulus. However, at the high dose this decrease was significantly less. Passenger-side line crossings significantly increased at the high dose. Conclusions These results suggest that driving impairment during secondary task performance may be associated with alcohol-related effects on the above brain regions, which are involved with attentional processing/decision-making. Drivers with high blood alcohol concentrations may be less able to orient or detect novel or sudden stimuli during driving. PMID:19183133
Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karunamuni, Roshan; Bartsch, Hauke; White, Nathan S.
Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thicknessmore » between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.« less
Shah, Ravi V.; McNulty, Steven; O'Connor, Christopher M.; Felker, G. Michael; Braunwald, Eugene; Givertz, Michael M.
2014-01-01
Background Results from the Diuretic Optimization Strategies in Acute Heart Failure (DOSE-AHF) study suggest that an initial continuous infusion of loop diuretics is not superior to bolus dosing with regard to clinical endpoints in AHF. We hypothesized that outpatient furosemide dose was associated with congestion and poorer renal function, and explored the hypothesis that a continuous infusion may be more effective in patients on higher outpatient diuretic doses. Methods DOSE-AHF randomized 308 patients within 24 hours of admission to high vs. low initial intravenous diuretic dose given as either a continuous infusion or bolus. We compared baseline characteristics and assessed associations between mode of administration (bolus vs. continuous) and outcomes in patients receiving high-dose (≥120 mg furosemide equivalent, n=177) versus low-dose (<120 mg furosemide equivalent, n=131) outpatient diuretics. Results Patients on higher doses of furosemide were less frequently on renin-angiotensin system inhibitors (P=.01), and had worse renal function and more advanced symptoms. There was a significant interaction between outpatient dose and mode of therapy (P=0.01) with respect to net fluid loss at 72 hours after adjusting for creatinine and intensification strategy. Admission diuretic dose was associated with an increased risk of death or rehospitalization at 60 days (adjusted HR=1.08 per 20-mg increment in dose, 95% CI 1.01–1.16, P=.03). Conclusions In acute HF, patients on higher diuretic doses have greater disease severity, and may benefit from an initial bolus strategy. PMID:23194486
Influence of royal jelly on the reproductive function of puberty male rats.
Yang, Anshu; Zhou, Ming; Zhang, Li; Xie, Guoxiu; Chen, Hongbing; Liu, Zhiyong; Ma, Wei
2012-06-01
The adverse effects of royal jelly on the reproductive system of puberty male rats were investigated. Royal jelly was daily administered by gavage to Sprague-Dawley rats at doses 200, 400, and 800 mg/kg for 4 weeks. The body weight and organ coefficients were determined. Sperm count, spermatozoa abnormality, and testicular histopathology were examined through light microscopy. Radioimmunoassay was used to detect serum hormones. The dietary exposure to royal jelly did not affect body weight, but the organ coefficients for the pituitary and testis in the high-dose group were decreased significantly compared with the control group, and significant changes in the microstructure of the testis were observed. No significant differences in sperm count were observed among all groups, however, the sperm deformity rate in the high-dose group increased significantly. Serum hormones in the high-dose group were significantly different from the control group. After royal jelly was stopped for 14 days, the adverse changes were partially reversed and returned to levels close to those in the control group. In conclusion, high-dose royal jelly oral administration for 4 weeks adversely affected the reproductive system of pubescent male rats, but the unfavorable effects are alleviated to some extent by cessation of administration. Copyright © 2012 Elsevier Ltd. All rights reserved.
High-dose short-term administration of naringin did not alter talinolol pharmacokinetics in humans.
Nguyen, M A; Staubach, P; Tamai, I; Langguth, P
2015-02-20
Naringin is considered the major causative ingredient of the inhibition of intestinal drug uptake by grapefruit juice. Moreover, it is contained in highly dosed nutraceuticals available on the market. A controlled, open, randomized, crossover study was performed in 10 healthy volunteers to investigate the effect of high-dose naringin on the bioavailability of talinolol, a substrate of intestinal organic anion-transporting polypeptide (OATP)-mediated uptake. Following 6-day supplementation with 3 capsules of 350 mg naringin daily, 100mg talinolol were administered orally with 3 capsules of the same dietary supplement (1050 mg naringin) on the seventh day. This test treatment was compared to 100mg talinolol only (control). The results showed that short-term high-dose naringin supplementation did not significantly affect talinolol pharmacokinetics. Geometric mean ratios of test versus control ranged between 0.90 and 0.98 for talinolol c(max), AUC(0-48 h), AUC(0-∞), t(1/2) and A(e(0-48 h)). The high dose may provoke inhibition of the efflux transporter P-glycoprotein (P-gp) which counteracts the uptake inhibition. As disintegration and dissolution processes are required for the solid dosage form, dissolved naringin may arrive at the site of interaction after talinolol is already absorbed. In conclusion, the effect of nutraceuticals on drug pharmacokinetics can deviate from that observed when administered as food component due to the different dose and dosage form. Copyright © 2014 Elsevier B.V. All rights reserved.
Staff Radiation Doses in a Real-Time Display Inside the Angiography Room
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Roberto, E-mail: rmsanchez.hcsc@salud.madrid.org; Vano, E.; Fernandez, J. M.
MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operatormore » exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, Martin A., E-mail: Martin.Ebert@health.wa.gov.au; School of Physics, University of Western Australia, Perth, Western Australia; Foo, Kerwyn
Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with amore » comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isohashi, Fumiaki, E-mail: isohashi@radonc.med.osaka-u.ac.j; Yoshioka, Yasuo; Koizumi, Masahiko
2010-07-01
Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculatedmore » by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorissen, BL; Giantsoudi, D; Unkelbach, J
Purpose: Cell survival experiments suggest that the relative biological effectiveness (RBE) of proton beams depends on linear energy transfer (LET), leading to higher RBE near the end of range. With intensity-modulated proton therapy (IMPT), multiple treatment plans that differ in the dose contribution per field may yield a similar physical dose distribution, but the RBE-weighted dose distribution may be disparate. RBE models currently do not have the required predictive power to be included in an optimization model due to the variations in experimental data. We propose an LET-based planning method that guides IMPT optimization models towards plans with reduced RBE-weightedmore » dose in surrounding organs at risk (OARs) compared to inverse planning based on physical dose alone. Methods: Optimization models for physical dose are extended with a term for dose times LET (doseLET). Monte Carlo code is used to generate the physical dose and doseLET distribution of each individual pencil beam. The method is demonstrated for an atypical meningioma patient where the target volume abuts the brainstem and partially overlaps with the optic nerve. Results: A reference plan optimized based on physical dose alone yields high doseLET values in parts of the brainstem and optic nerve. Minimizing doseLET in these critical structures as an additional planning goal reduces the risk of high RBE-weighted dose. The resulting treatment plan avoids the distal fall-off of the Bragg peaks for shaping the dose distribution in front of critical stuctures. The maximum dose in the OARs evaluated with RBE models from literature is reduced by 8–14\\% with our method compared to conventional planning. Conclusion: LET-based inverse planning for IMPT offers the ability to reduce the RBE-weighted dose in OARs without sacrificing target dose. This project was in part supported by NCI - U19 CA 21239.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massimino, Maura; Gandola, Lorenza; Spreafico, Filippo
Purpose: Myeloablative regimens were frequently used for medulloblastoma relapsing after craniospinal irradiation (CSI): in 1997-2002, we used repeated surgery, standard-dose and myeloablative chemotherapy, and reirradiation. Methods and Materials: In 10 patients, reinduction included sequential high-dose etoposide, high-dose cyclophosphamide/vincristine, and high-dose carboplatin/vincristine, then two myeloablative courses with high-dose thiotepa ({+-} carboplatin); 6 other patients received two of four courses of cisplatin/etoposide. Hematopoietic precursor mobilization followed high-dose etoposide or high-dose cyclophosphamide or cisplatin/etoposide therapy. After the overall chemotherapy program, reirradiation was prescribed when possible. Results: Seventeen patients were treated: previous treatment included CSI of 19.5-36 Gy with posterior fossa/tumor boost and chemotherapymore » in 16 patients. Fifteen patients were in their first and 2 in their second and third relapses, respectively. First progression-free survival had lasted a median of 26 months. Relapse sites included leptomeninges in 9 patients, spine in 4 patients, posterior fossa in 3 patients, and brain in 1 patient. Three patients underwent complete resection of recurrence, and 10 underwent reirradiation. Twelve of 14 patients with assessable tumor had an objective response after reinduction; 2 experienced progression and were not given the myeloablative courses. Remission lasted a median of 16 months. Additional relapses appeared in 13 patients continuing the treatment. Fifteen patients died of progression and 1 died of pneumonia 13 months after relapse. The only survivor at 93 months had a single spinal metastasis that was excised and irradiated. Survival for the series as a whole was 11-93 months, with a median of 41 months. Conclusions: Despite responses being obtained and ample use of surgery and reirradiation, second-line therapy with myeloablative schedules was not curative, barring a few exceptions. A salvage therapy for medulloblastoma after CSI still needs to be sought.« less
Christakopoulos, Georgios E.; Christopoulos, Georgios; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W.; Jaffer, Farouc A.; Wyman, Michael R.; Lombardi, William L.; Tarar, Muhammad Nauman J.; Grantham, J. Aaron; Kandzari, David; Lembo, Nicholas; Moses, Jeffrey W.; Kirtane, Ajay; Parikh, Manish; Green, Philip; Finn, Matthew; Garcia, Santiago; Doing, Anthony; Hatem, Raja; Thompson, Craig A.; Banerjee, Subhash; Brilakis, Emmanouil S.
2016-01-01
Background High patient radiation dose during chronic total occlusion (CTO) percutaneous coronary intervention (PCI) may lead to procedural failure and radiation skin injury. Methods We examined the association between several clinical and angiographic variables on patient air kerma (AK) radiation dose among 748 consecutive CTO PCIs performed at 9 experienced US centers between May 2012 and May 2015. Results Mean age was 65±10 years, 87% of patients were men, and 35% had prior coronary artery bypass graft surgery (CABG). Technical and procedural success was 92% and 90%, respectively. The median patient AK dose was 3.40 (2.00, 5.40) Gray and 34% of the patients received >4.8 Gray (high radiation exposure). On univariable analysis male gender (p=0.016), high body mass index (p<0.001), history of hyperlipidemia (p=0.023), prior CABG (p<0.001), moderate or severe calcification (p<0.001), tortuosity (p<0.001), proximal cap ambiguity (p=0.001), distal cap at a bifurcation (p=0.006), longer CTO occlusion length (p<0.001), blunt/no blunt stump (p<0.001), and center (<0.001) were associated with higher patient AK dose. On multivariable analysis high body mass index (p<0.001), prior CABG (p=0.005), moderate or severe calcification (p=0.005), longer CTO occlusion length (p<0.001), and center (p<0.001) were independently associated with higher patient AK dose. Conclusions Approximately 1 in 3 patients undergoing CTO PCI receives high AK radiation dose (>4.8 Gray). Several baseline clinical and angiographic characteristics can help predict the likelihood of high radiation dose and assist with intensifying efforts to reduce radiation exposure for the patient and the operator. PMID:28169091
Phase 1 Trial of Sorafenib and Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brade, Anthony M., E-mail: anthony.brade@rmp.uhn.on.ca; Department of Radiation Oncology, Faculty of Medicine, University of Toronto, Toronto, Ontario; Ng, Sylvia
Purpose: To determine the maximally tolerated dose of sorafenib delivered before, during, and after stereotactic body radiation therapy (SBRT) in hepatocellular carinoma (HCC). Methods and Materials: Eligible patients had locally advanced Child-Pugh class A HCC, showed Eastern Cooperative Oncology Group performance status 0-1, and were ineligible for standard local-regional therapies. Sorafenib was dose escalated in 2 strata: (1) low effective irradiated liver volume (veff) < 30% and (2) high veff 30%to 60%. Sorafenib (400 mg daily = dose level 1) was administered for 12 weeks, with 6 fractions SBRT delivered weeks 2 and 3, and escalation to full dose (400 mg twice daily) after 12 weeks as tolerated.more » Standard 3 + 3 cohorts with dose escalation of sorafenib were planned. Results: Sixteen patients (4 low veff, median dose 51 Gy; 12 high veff, median dose 33 Gy) were treated at 2 sorafenib dose levels. Of those patients 75% were had Barcelona Clinic Liver Cancer stage C, and 63% had main branch portal vein invasion. In the low veff stratum, no dose-limiting toxicities (DLTs) were observed in 4 patients treated with SBRT and sorafenib 400 mg. Inb the high veff stratum: 2 of 3 evaluable patients treated with sorafenib 400 mg experienced DLT (grade 3 large bowel bleed and grade 4 bowel obstruction 51 and 27 days, respectively, after SBRT). One of 6 evaluable patients at dose level −1 (200 mg once daily) experienced a grade 3 tumor rupture at week 5. Median overall survival and in-field local progression have not been reached. Worsening of Child-Pugh liver function class was seen in 6 of 12 patients in the high veff stratum. Conclusions: Significant toxicity was observed in the high veff stratum, and concurrent SBRT with sorafenib is not recommended outside a clinical trial.« less
Kowal, Mikael A; Hazekamp, Arno; Colzato, Lorenza S; van Steenbergen, Henk; van der Wee, Nic J A; Durieux, Jeffrey; Manai, Meriem; Hommel, Bernhard
2015-03-01
Cannabis users often claim that cannabis has the potential to enhance their creativity. Research suggests that aspects of creative performance might be improved when intoxicated with cannabis; however, the evidence is not conclusive. The aim of this study was to investigate the acute effects of cannabis on creativity. We examined the effects of administering a low (5.5 mg delta-9-tetrahydrocannabinol [THC]) or high (22 mg THC) dose of vaporized cannabis vs. placebo on creativity tasks tapping into divergent (Alternate Uses Task) and convergent (Remote Associates Task) thinking, in a population of regular cannabis users. The study used a randomized, double-blind, between-groups design. Participants in the high-dose group (n = 18) displayed significantly worse performance on the divergent thinking task, compared to individuals in both the low-dose (n = 18) and placebo (n = 18) groups. The findings suggest that cannabis with low potency does not have any impact on creativity, while highly potent cannabis actually impairs divergent thinking.
Kshirsagar, Abhijit V.; Freburger, Janet K.; Ellis, Alan R.; Wang, Lily; Winkelmayer, Wolfgang C.; Brookhart, M. Alan
2013-01-01
Background & Objectives Intravenous iron supplementation is widespread in the hemodialysis population, but there is uncertainty about the safest dosing strategy. We compared the safety of different intravenous iron dosing practices on the risk of adverse cardiovascular outcomes in a large population of hemodialysis patients. Design settings, participants, & measurements A retrospective cohort was created from the clinical database of a large dialysis provider (years 2004-2008) merged with administrative data from the United States Renal Data System. Dosing comparisons were (1) bolus (consecutive doses ≥ 100 mg exceeding 600 mg during one month) versus maintenance (all other iron doses during the month); and (2) high (> 200 mg over 1 month) versus low dose (≤ 200 mg over 1 month). We established a 6-month baseline period (to identify potential confounders and effect modifiers), a one-month iron exposure period, and a three-month follow-up period. Outcomes were myocardial infarction, stroke, and death from cardiovascular disease. Results 117,050 patients contributed 776,203 unique iron exposure/follow-up periods. After adjustment, we found no significant associations of bolus dose versus maintenance, hazards ratio for composite outcome, 1.03 (95% C.I. 0.99, 1.07), or high dose versus low dose intravenous iron, hazards ratio for composite outcome, 0.99 (95% C.I. 0.96, 1.03). There were no consistent associations of either high or bolus dose versus low or maintenance respectively among pre-specified subgroups. Conclusions Strategies favoring large doses of intravenous iron were not associated with increased short-term cardiovascular morbidity and mortality. Investigation of the long-term safety of the various intravenous iron supplementation strategies may still be warranted. PMID:24223866
Thrall, Donald E.; LaRue, Susan M.; Yu, Daohai; Samulski, Thaddeus; Sanders, Linda; Case, Beth; Rosner, Gary; Azuma, Chieko; Poulson, Jeannie; Pruitt, Amy F.; Stanley, Wilma; Hauck, Marlene L.; Williams, Laurel; Hess, Paul; Dewhirst, Mark W.
2009-01-01
Purpose To test that prospective delivery of higher thermal dose is associated with longer tumor control duration. Experimental Design 122 dogs with a heatable soft tissue sarcoma were randomized to receive a low (2–5 CEM43°CT90) or high (20–50 CEM43°CT90) thermal dose in combination with radiotherapy. Most dogs (90%) received 4–6 hyperthermia treatments over 5 weeks. Results In the primary analysis, median (95% CI) duration of local control in the low dose group was 1.2 (0.7–2.1) years versus 1.9 (1.4–3.2) years in the high dose group (logrank p=0.28). The probability (95% CI) of tumor control at one year in the low vs. high dose groups was 0.57 (0.43–0.70) vs. 0.74 (0.62–0.86), respectively. Using multivariable procedure, thermal dose group (p=0.023), total duration of heating (p=0.008), tumor volume (p=0.041) and tumor grade (p=0.027) were significantly related to duration of local tumor control. When correcting for volume, grade and duration of heating, dogs in the low dose group were 2.3 times as likely to experience local failure. Conclusions Thermal dose is directly related to local control duration in irradiated canine sarcomas. Longer heating being associated with shorter local tumor control was unexpected. However, the effect of thermal dose on tumor control was stronger than for heating duration. The heating duration effect is possibly mediated through deleterious effects on tumor oxygenation. These results are the first to show the value of prospectively controlled thermal dose in achieving local tumor control with thermoradiotherapy, and they establish a paradigm for prescribing thermoradiotherapy and writing a thermal prescription. PMID:16033838
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karlsson, Kristin, E-mail: kristin.karlsson@karolinska.se; Department of Oncology-Pathology, Karolinska Institute, Stockholm; Nyman, Jan
2013-11-01
Purpose: To evaluate the dose–response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Methods and Materials: Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm{sup 3} up to 2.0 cm{sup 3}]) was statistically evaluated with survival analysis models. Results: Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showedmore » a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm{sup 3} (D{sub 0.1cm3}) was used for further analysis. The median value of D{sub 0.1cm3} (α/β = 3 Gy) was EQD{sub 2,LQ} = 147 Gy{sub 3} (range, 20-293 Gy{sub 3}). For patients who developed atelectasis the median value was EQD{sub 2,LQ} = 210 Gy{sub 3}, and for patients who did not develop atelectasis, EQD{sub 2,LQ} = 105 Gy{sub 3}. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). Conclusion: In this retrospective study a significant dose–response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown.« less
Who Gets the Most Out of Cognitive-Behavioral Therapy for Anxiety Disorders?
Glenn, Daniel; Golinelli, Daniela; Rose, Raphael D.; Roy-Byrne, Peter; Stein, Murray B.; Sullivan, Greer; Bystritksy, Alexander; Sherbourne, Cathy; Craske, Michelle G.
2013-01-01
Objective The present study explored treatment dose and patient engagement as predictors of treatment outcome in cognitive behavioral therapy (CBT) for anxiety disorders. Method Measures of high versus low treatment dose, and high versus low patient engagement in CBT were compared as predictors of 12 and 18 month outcomes for patients being treated for anxiety disorders with CBT (with or without concurrent pharmacotherapy) in primary care settings as part of a randomized controlled effectiveness trial of the Coordinated Anxiety Learning and Management (CALM) intervention. Measures of dose (attendance, exposure completion) and engagement in CBT (homework adherence, commitment) were collected throughout treatment, and blinded follow-up phone assessments of outcome measures (12-item Brief Symptom Inventory, Patient Health Questionnaire 8, Sheehan Disability Scale) were completed at 12 and 18 months. Propensity score weighting controlled for baseline differences in demographics and symptom severity between patients with high and low dose and engagement. These analyses included the 439 patients that selected CBT as treatment modality. Results Completing exposures, high attendance, and being more homework adherent predicted better outcomes across all measures at 12 and 18 months, and high CBT commitment predicted better outcomes on all measures at 18 months. Conclusions This study found that higher treatment dose and patient engagement in CBT for anxiety disorders were stable and robust predictors of greater reductions in anxiety symptoms, depression symptoms, and functional disability. PMID:23750465
Kiefer, T; Krüger, W H; Schüler, F; Lotze, C; Hirt, C; Dölken, G
2006-06-01
Infections during neutropaenia contribute still significantly to mortality and morbidity after high-dose therapy and autologous stem cell transplantation. Further acceleration of haemopoietic recovery seems impossible for biological reasons. Another approach to shorten neutropaenia could be to remove drugs from high-dose therapy protocols with strong contribution to immunosuppression and neutropaenia and unproven antineoplastic activity. In this retrospective matched-pair analysis, conventional busulphan/cyclophosphamide (Bu/Cy) high-dose therapy was compared to single-agent busulphan conditioning before autologous stem cell transplantation. This modification led to a significant shorter neutropaenic interval by protraction of cell decrease and to a significant mitigation of neutropaenia. After single-agent busulphan conditioning, leucocytes dropped below 1/nl at median 1.5 days later when compared to the patients from the busulphanBu/Cy control group (P=0.001). In a significant percentage of patients (n=6, 60%) leucocytes did not fall below 0.5 cells/nl at any time. In contrast, all patients from the Bu/Cy control group experienced deep neutropaenia (P=0.004). Thrombocytopaenia and requirement for transfusions of platelets or red cells were not influenced. Antineoplastic activity seemed to be preserved as determined by survival analysis. In conclusion, modification of high-dose regimen with the intention to shorten neutropaenia with preserved antitumour activity could be an approach to reduce infection-related morbidity and mortality and to consider economic necessities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massager, Nicolas, E-mail: nmassage@ulb.ac.be; Neurosurgery-Department, Hospital Erasme, Brussels; Lonneville, Sarah
2011-11-15
Objectives: We investigated variations in the distribution of radiation dose inside (dose inhomogeneity) and outside (dose falloff) the target volume during Gamma Knife (GK) irradiation of vestibular schwannoma (VS). We analyzed the relationship between some parameters of dose distribution and the clinical and radiological outcome of patients. Methods and Materials: Data from dose plans of 203 patients treated for a vestibular schwannoma by GK C using same prescription dose (12 Gy at the 50% isodose) were collected. Four different dosimetric indexes were defined and calculated retrospectively in all plannings on the basis of dose-volume histograms: Paddick conformity index (PI), gradientmore » index (GI), homogeneity index (HI), and unit isocenter (UI). The different measures related to distribution of the radiation dose were compared with hearing and tumor outcome of 203 patients with clinical and radiological follow-up of minimum 2 years. Results: Mean, median, SD, and ranges of the four indexes of dose distribution analyzed were calculated; large variations were found between dose plans. We found a high correlation between the target volume and PI, GI, and UI. No significant association was found between the indexes of dose distribution calculated in this study and tumor control, tumor volume shrinkage, hearing worsening, loss of functional hearing, or complete hearing loss at last follow-up. Conclusions: Parameters of distribution of the radiation dose during GK radiosurgery for VS can be highly variable between dose plans. The tumor and hearing outcome of patients treated is not significantly related to these global indexes of dose distribution inside and around target volume. In GK radiosurgery for VS, the outcome seems more to be influenced by local radiation dose delivered to specific structures or volumes than by global dose gradients.« less
Chatelain, P; Job, J C; Blanchard, J; Ducret, J P; Oliver, M; Sagnard, L; Vanderschueren-Lodeweyckx, M
1994-06-01
This study reports the results of a 2-yr clinical trial with GH in 95 short prepubertal children with non-GH-deficient intrauterine growth retardation. This randomized, double blind, controlled study compared the effects of placebo (restricted to the first 6 months) and two doses of GH (0.4 and 1.2 IU/kg.week) given sc 6 days/week for 2 yr. A significant GH dose-dependent growth acceleration was observed. Mean height gain (SDS/CA) was 0.66 +/- 0.07 in group I (low dose, 0.4 IU/kg.week) compared to 1.25 +/- 0.07 in group II (high dose, 1.2 IU/kg.week). Mean bone maturation progression (expressed in months) was 26.2 +/- 1.7 and 30.2 +/- 1.5 over 24 months in groups I and II, respectively. Onset of puberty was observed in some patients of both groups. Whether chronic use of a high GH dose will advance the onset of puberty remains to be established. A great variability of growth acceleration was seen among GH dose groups, suggesting that factors in addition to GH dose might modulate individual responses to treatment. In conclusion, it is suggested that in these patients, dose-dependent catch-up growth could be induced by GH treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karsch, L.; Beyreuther, E.; Burris-Mog, T.
Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the numbermore » of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lloyd, S. A. M.; Ansbacher, W.; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 3P6
2013-01-15
Purpose: Acuros external beam (Acuros XB) is a novel dose calculation algorithm implemented through the ECLIPSE treatment planning system. The algorithm finds a deterministic solution to the linear Boltzmann transport equation, the same equation commonly solved stochastically by Monte Carlo methods. This work is an evaluation of Acuros XB, by comparison with Monte Carlo, for dose calculation applications involving high-density materials. Existing non-Monte Carlo clinical dose calculation algorithms, such as the analytic anisotropic algorithm (AAA), do not accurately model dose perturbations due to increased electron scatter within high-density volumes. Methods: Acuros XB, AAA, and EGSnrc based Monte Carlo are usedmore » to calculate dose distributions from 18 MV and 6 MV photon beams delivered to a cubic water phantom containing a rectangular high density (4.0-8.0 g/cm{sup 3}) volume at its center. The algorithms are also used to recalculate a clinical prostate treatment plan involving a unilateral hip prosthesis, originally evaluated using AAA. These results are compared graphically and numerically using gamma-index analysis. Radio-chromic film measurements are presented to augment Monte Carlo and Acuros XB dose perturbation data. Results: Using a 2% and 1 mm gamma-analysis, between 91.3% and 96.8% of Acuros XB dose voxels containing greater than 50% the normalized dose were in agreement with Monte Carlo data for virtual phantoms involving 18 MV and 6 MV photons, stainless steel and titanium alloy implants and for on-axis and oblique field delivery. A similar gamma-analysis of AAA against Monte Carlo data showed between 80.8% and 87.3% agreement. Comparing Acuros XB and AAA evaluations of a clinical prostate patient plan involving a unilateral hip prosthesis, Acuros XB showed good overall agreement with Monte Carlo while AAA underestimated dose on the upstream medial surface of the prosthesis due to electron scatter from the high-density material. Film measurements support the dose perturbations demonstrated by Monte Carlo and Acuros XB data. Conclusions: Acuros XB is shown to perform as well as Monte Carlo methods and better than existing clinical algorithms for dose calculations involving high-density volumes.« less
Huang, Xian-Ju; Ihsan, Awais; Wang, Xu; Dai, Meng-Hong; Wang, Yu-Lian; Su, Shi-Jia; Xue, Xi-Juan; Yuan, Zong-Hui
2009-12-15
Mequindox (MEQ) is a synthetic quinoxaline 1,4-dioxides (QdNOs) derivative which can effectively improve growth and feed efficiency in animals. This study was to investigate the dose-dependent long-term toxicity in the adrenal of male rats exposed to 180 days of MEQ feed. Our data demonstrated that high doses of MEQ in the diet for 180 days led to adrenal damage and steroid hormone decrease, combined with sodium decrease and potassium increase in rat plasma. Significant changes of GSH and SOD in plasma were observed in the high doses (110, 275 mg/kg) groups. At the same doses, MEQ treatment down-regulated the mRNA levels of CYP11A1, CYP11B1 and CYP11B2 which located in mitochondria, but up-regulated mRNA levels of CYP21 and 3beta-HSD which located in endoplasmic reticulum. In conclusion, we reported the dose-dependent long-term toxicity of MEQ on adrenal gland in male rats, which raise awareness of its toxic effects to animals and consumers, and its mechanism may involve in oxidative stress and steroid hormone biosynthesis pathway.
Liao, Shang-Chih; Hung, Cheng-Chieh; Lee, Chien-Te; Lee, Chih-Hsiung; Lee, Chin-Chan; Lin, Chun-Liang; Sun, Chiao-Yin; Cheng, Ben-Chung; Yang, Chih-Chao; Wu, Chien-Hsing; Chen, Jin-Bor
2016-08-01
This multicenter study was designed to assess the hemoglobin (Hb) stability and conversion ratio of the switch from epoetin beta to darbepoetin alfa in Taiwanese hemodialysis (HD) patients. A total of 135 HD patients were enrolled and randomized with intravenous darbepoetin alfa or epoetin beta. The study duration was 24 weeks. Equivalent doses and conversion ratios were assessed with respect to Hb stratification: low Hb (≥8.0 g/dL to ≤10.0 g/dL) and high Hb (>10.0 g/dL to ≤11.0 g/dL). The results showed stable Hb levels in the study period. At week 24, the conversion ratio was higher for high Hb than low Hb (296.4 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa. vs. 277.2 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa). In conclusion, the conversion ratio in the present study was higher than 1 µg: 200 IU for darbepoetin alfa: epoetin for treating anemia in Taiwanese HD patients. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Müller, Daniel J.; Ng, Chee H.; Byron, Keith; Berk, Michael; Singh, Ajeet B.
2017-01-01
Background Pharmacogenetic-based dosing support tools have been developed to personalize antidepressant-prescribing practice. However, the clinical validity of these tools has not been adequately tested, particularly for specific antidepressants. Objective To examine the concordance between the actual dose and a polygene pharmacogenetic predicted dose of desvenlafaxine needed to achieve symptom remission. Materials and methods A 10-week, open-label, prospective trial of desvenlafaxine among Caucasian adults with major depressive disorder (n=119) was conducted. Dose was clinically adjusted and at the completion of the trial, the clinical dose needed to achieve remission was compared with the predicted dose needed to achieve remission. Results Among remitters (n=95), there was a strong concordance (Kendall’s τ-b=0.84, P=0.0001; Cohen’s κ=0.82, P=0.0001) between the actual and the predicted dose need to achieve symptom remission, showing high sensitivity (≥85%), specificity (≥86%), and accuracy (≥89%) of the tool. Conclusion Findings provide initial evidence for the clinical validity of a polygene pharmacogenetic-based tool for desvenlafaxine dosing. PMID:27779571
Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus
2016-01-01
The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. PMID:26994093
Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus
2016-06-01
The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. © The Author 2016. Published by Oxford University Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshpande, S; Dhote, D; Kumar, R
Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens dosesmore » were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT.« less
Ueda, Tamenobu; Kai, Hisashi; Imaizumi, Tsutomu
2012-07-01
The treatment of morning hypertension has not been established. We compared the efficacy and safety of a losartan/hydrochlorothiazide (HCTZ) combination and high-dose losartan in patients with morning hypertension. A prospective, randomized, open-labeled, parallel-group, multicenter trial enrolled 216 treated outpatients with morning hypertension evaluated by home blood pressure (BP) self-measurement. Patients were randomly assigned to receive a combination therapy of 50 mg losartan and 12.5 mg HCTZ (n=109) or a high-dose therapy with 100 mg losartan (n=107), each of which were administered once every morning. Primary efficacy end points were morning systolic BP (SBP) level and target BP achievement rate after 3 months of treatment. At baseline, BP levels were similar between the two therapy groups. Morning SBP was reduced from 150.3±10.1 to 131.5±11.5 mm Hg by combination therapy (P<0.001) and from 151.0±9.3 to 142.5±13.6 mm Hg by high-dose therapy (P<0.001). The morning SBP reduction was greater in the combination therapy group than in the high-dose therapy group (P<0.001). Combination therapy decreased evening SBP from 141.6±13.3 to 125.3±13.1 mm Hg (P<0.001), and high-dose therapy decreased evening SBP from 138.9±9.9 to 131.4±13.2 mm Hg (P<0.01). Although both therapies improved target BP achievement rates in the morning and evening (P<0.001 for both), combination therapy increased the achievement rates more than high-dose therapy (P<0.001 and P<0.05, respectively). In clinic measurements, combination therapy was superior to high-dose therapy in reducing SBP and improving the achievement rate (P<0.001 and P<0.01, respectively). Combination therapy decreased urine albumin excretion (P<0.05) whereas high-dose therapy reduced serum uric acid. Both therapies indicated strong adherence and few adverse effects (P<0.001). In conclusion, losartan/HCTZ combination therapy was more effective for controlling morning hypertension and reducing urine albumin than high-dose losartan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luijk, Peter van; Faber, Hette; Schippers, Jacobus M.
2009-07-15
Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect). Methods and Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.e., subtolerance) dose levels for a bath-dose, both whole parotid glands were irradiated with 5 to 25 Gy. Subsequently groups of Wistar rats received 30 Gy to the caudal 50% (shower) and 0 to 10 Gy to the cranial 50% (bath) ofmore » both parotid glands. Stimulated saliva flow rate (function) was measured before and up to 240 days after irradiation. Results: Irradiation of both glands up to a dose of 10 Gy did not result in late loss of function and is thus regarded subtolerance. Addition of a dose bath of 1 to 10 Gy to a high-dose in the caudal 50% of the glands resulted in enhanced function loss. Conclusion: Similar to the spinal cord, the parotid gland demonstrates a bath and shower effect, which may explain the less-than-expected sparing of function after IMRT.« less
Hohaus, S; Funk, L; Martin, S; Schlenk, R F; Abdallah, A; Hahn, U; Egerer, G; Goldschmidt, H; Schneeweiß, A; Fersis, N; Kaul, S; Wallwiener, D; Bastert, G; Haas, R
1999-01-01
We report on the efficacy and toxicity of a sequential high-dose therapy with peripheral blood stem cell (PBSC) support in 85 patients with high-risk stage II/III breast cancer. There were 71 patients with more than nine tumour-positive axillary lymph nodes. An induction therapy of two cycles of ifosfamide (total dose, 7.5 g m−2) and epirubicin (120 mg m−2) was given, and PBSC were harvested during G-CSF-supported leucocyte recovery following the second cycle. The PBSC-supported high-dose chemotherapy consisted of two cycles of ifosfamide (total dose, 12 000 mg m−2), carboplatin (900 mg m−2) and epirubicin (180 mg m−2). Patients were autografted with a median number of 3.7 × 106 CD34+ cells kg−1 (range, 1.9–26.5 × 106) resulting in haematological reconstitution within approximately 2 weeks following high-dose therapy. The toxicity was moderate in general, and there was no treatment-related toxic death. Twenty-one patients relapsed between 3 and 30 months following the last cycle of high-dose therapy (median, 11 months). The probability of disease-free and overall survival at 4 years were 60% and 83%, respectively. According to a multivariate analysis, patients with stage II disease had a significantly better probability of disease-free survival (74%) in comparison to patients with stage III disease (36%). The probability of disease-free survival was also significantly better for patients with oestrogen receptor-positive tumours (70%) compared to patients with receptor-negative ones (40%). Bone marrow samples collected from 52 patients after high-dose therapy were examined to evaluate the prognostic relevance of isolated tumour cells. The proportion of patients presenting with tumour cell-positive samples did not change in comparison to that observed before high-dose therapy (65% vs 71%), but a decrease in the incidence and concentration of tumour cells was observed over time after high-dose therapy. This finding was true for patients with relapse and for those in remission, which argues against a prognostic significance of isolated tumour cells in bone marrow. In conclusion, sequential high-dose chemotherapy with PBSC support can be safely administered to patients with high-risk stage II/III breast cancer. Further intensification of the therapy, including the addition of non-cross resistant drugs or immunological approaches such as the use of antibodies against HER-2/NEU, may be envisaged for patients with stage III disease and hormone receptor-negative tumours. © 1999 Cancer Research Campaign PMID:10188897
Barnwal, Neeraj Kumar; Umbarkar, Sanjeeta Rajendra; Sarkar, Manjula Sudeep; Dias, Raylene J
2017-01-01
Background: Pulmonary hypertension secondary to congenital heart disease is a common problem in pediatric patients presenting for open heart surgery. Milrinone has been shown to reduce pulmonary vascular resistance and pulmonary artery pressure in pediatric patients and neonates postcardiac surgery. We aimed to evaluate the postoperative outcome in such patients with three different fixed maintenance doses of milrinone. Methodology: Patients were randomized into three groups. All patients received fixed bolus dose of milrinone 50 μg/kg on pump during rewarming. Following this, patients in low-dose group received infusion of milrinone at the rate of 0.375 μg/kg/min, medium-dose group received 0.5 μg/kg/min, and high-dose group received 0.75 μg/kg/min over 24 h. Heart rate, mean arterial pressure (MAP), mean airway pressure (MaP), oxygenation index (OI), and central venous pressure (CVP) were compared at baseline and 24 h postoperatively. Dose of inotropic requirement, duration of ventilatory support and Intensive Care Unit (ICU) stay were noted. Results: MAP, MaP, OI, and CVP were comparable in all three groups postoperatively. All patients in the low-dose group required low inotropic support while 70% of patients in the high-dose group needed high inotropic support to manage episodes of hypotension (P = 0.000). Duration of ventilatory support and ICU stay in all three groups was comparable (P = 0.412, P = 0.165). Conclusion: Low-dose infusions while having a clinical impact were more beneficial in avoiding adverse events and decreasing inotropic requirement without affecting duration of ventilatory support and duration of ICU stay. PMID:28701597
Fujimoto, Koichi; Kanazawa, Katsunori; Takemoto, Koji; Urasaki, Kokichi; Ueda, Yutaka; Ubukata, Kimiko; Sunakawa, Keisuke
2013-08-01
The purpose of this study was to investigate the relationship between efficacy and percentage of time above the MIC (%T>MIC) in the cerebrospinal fluid (CSF) for different dosing regimens of meropenem against an experimental lethal meningitis model in guinea pigs with type b β-lactamase-nonproducing ampicillin-resistant Haemophilus influenzae (Hib BLNAR). Guinea pigs were intrathecally inoculated with 10(8) CFU/head of Hib BLNAR 8 h before the start of therapy. A single dose of 20, 40, or 80 mg/kg meropenem or multiple doses of 40 mg/kg meropenem were subcutaneously administered. Numbers of bacteria in CSF were counted 8 h after the start of therapy. Meropenem concentration in serum and CSF were determined in infected guinea pigs receiving a single dose of 40 mg/kg. In the single-dose regimen, 40 and 80 mg/kg meropenem significantly reduced the number of bacteria in CSF compared with the control, but 20 mg/kg meropenem did not. The %T>MIC for an 8-h period of 20, 40, and 80 mg/kg meropenem were 41, 52, and 62, respectively. Two and four doses of 40 mg/kg meropenem, for both of which %T>MIC was calculated as 100, had similar efficacy and were significantly superior to a single-dose of 40 mg/kg. In conclusion, meropenem had high efficacy when %T>MIC in the CSF was increased because of the high dose level and shortening of the dosing interval in a guinea pig meningitis model caused by Hib BLNAR, suggesting that high and frequent doses of meropenem are useful for treatment of meningitis with Hib BLNAR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arentsen, L; Lopater, Z; Dusenbery, K
Purpose: Duputren’s contracture (DC) is a benign disease characterized by abnormal thickening of the fascial surfaces of the hands or feet causing curling of the surface, functional impairment, weakness, and pain. The purpose of the investigation is to describe the radiation treatment approaches, compare these techniques, and discuss the potential side effects and complications of these techniques. Methods: Early stage DC has been treated with 120 kVp X rays but also with high-energy electrons or photons. High-energy electrons have been the radiation of choice but severe contracture of the hand makes it difficult to produce a plan with acceptable dosemore » uniformity. High-energy photons can overcome this difficulty either by directing a beam onto the palmer or back of the surface of the hand, including bolus to maximize the surface dose. We calculated the dose to the bone for the 120 kVp treatment using published %DD data and mass energy absorption coefficients for bone and muscle. Results: The dose to underlying bone from megavoltage photons and electrons is essentially the same, but dose to the bone for using 120 kVp can be 4–5 times greater due to the photoelectric effect. For the 30 Gy dose deliver using this technique, the dose to the bone could be 84–105 Gy after taking the penetration of the beam into account. After radiotherapy, there is often decreased osteoblastic activity and vascular fibrosis that leads to osteitis, atrophy, and decreased metabolic bone activity. Incidence of fractures occurs routinely above 60 Gy with higher doses potentially leading to higher incidences of bone complications. Conclusion: Radiation therapy for DC using low-energy X rays can deliver a prohibitively high dose to the underlying bone potentially leading to severe bone complications.« less
Low or High Fractionation Dose {beta}-Radiotherapy for Pterygium? A Randomized Clinical Trial
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viani, Gustavo Arruda, E-mail: gusviani@gmail.com; De Fendi, Ligia Issa; Fonseca, Ellen Carrara
2012-02-01
Purpose: Postoperative adjuvant treatment using {beta}-radiotherapy (RT) is a proven technique for reducing the recurrence of pterygium. A randomized trial was conducted to determine whether a low fractionation dose of 2 Gy within 10 fractions would provide local control similar to that after a high fractionation dose of 5 Gy within 7 fractions for surgically resected pterygium. Methods: A randomized trial was conducted in 200 patients (216 pterygia) between February 2006 and July 2007. Only patients with fresh pterygium resected using a bare sclera method and given RT within 3 days were included. Postoperative RT was delivered using a strontium-90more » eye applicator. The pterygia were randomly treated using either 5 Gy within 7 fractions (Group 1) or 2 Gy within 10 fractions (Group 2). The local control rate was calculated from the date of surgery. Results: Of the 216 pterygia included, 112 were allocated to Group 1 and 104 to Group 2. The 3-year local control rate for Groups 1 and 2 was 93.8% and 92.3%, respectively (p = .616). A statistically significant difference for cosmetic effect (p = .034), photophobia (p = .02), irritation (p = .001), and scleromalacia (p = .017) was noted in favor of Group 2. Conclusions: No better local control rate for postoperative pterygium was obtained using high-dose fractionation vs. low-dose fractionation. However, a low-dose fractionation schedule produced better cosmetic effects and resulted in fewer symptoms than high-dose fractionation. Moreover, pterygia can be safely treated in terms of local recurrence using RT schedules with a biologic effective dose of 24-52.5 Gy{sub 10.}.« less
Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.
KuKanich, Butch; Warner, Matt; Hahn, Kevin
2017-02-01
OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.
High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death
Ray, Wayne A.; Chung, Cecilia P.; Murray, Katherine T.; Hall, Kathi; Stein, C. Michael
2018-01-01
Objective Studies demonstrating higher doses of citalopram (>40mg) and escitalopram (>20mg) prolong the QTc interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these SSRIs to that for equivalent doses of fluoxetine, paroxetine, and sertraline. Method The Tennessee Medicaid retrospective cohort study included 54,220 persons 30–74 years of age without cancer or other life-threatening illness prescribed high-dose SSRIs. The mean age was 47 years and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of pro-arrhythmic effects. Results The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% confidence interval [CI], 0.40–1.75), 1.24 (0.75–2.05), 0.75 (0.45–1.24), and 1.53 (0.91–2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study endpoint. Conclusions We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. PMID:27736049
NASA Technical Reports Server (NTRS)
Plante, I.; Cucinotta, F. A.
2010-01-01
INTRODUCTION: The radiation track structure is of crucial importance to understand radiation damage to molecules and subsequent biological effects. Of a particular importance in radiobiology is the induction of double-strand breaks (DSBs) by ionizing radiation, which are caused by clusters of lesions in DNA, and oxidative damage to cellular constituents leading to aberrant signaling cascades. DSB can be visualized within cell nuclei with gamma-H2AX experiments. MATERIAL AND METHODS: In DSB induction models, the DSB probability is usually calculated by the local dose obtained from a radial dose profile of HZE tracks. In this work, the local dose imparted by HZE ions is calculated directly from the 3D Monte-Carlo simulation code RITRACKS. A cubic volume of 5 micron edge (Figure 1) is irradiated by a (Fe26+)-56 ion of 1 GeV/amu (LET approx.150 keV/micron) and by a fluence of 450 H+ ions, 300 MeV/amu (LET approx. 0.3 keV/micron). In both cases, the dose deposited in the volume is approx.1 Gy. The dose is then calculated into each 3D pixels (voxels) of 20 nm edge and visualized in 3D. RESULTS AND DISCUSSION: The dose is deposited uniformly in the volume by the H+ ions. The voxels which receive a high dose (orange) corresponds to electron track ends. The dose is deposited differently by the 56Fe26+ ion. Very high dose (red) is deposited in voxels with direct ion traversal. Voxels with electron track ends (orange) are also found distributed around the path of the track. In both cases, the appearance of the dose distribution looks very similar to DSBs seen in gammaH2AX experiments, particularly when the visualization threshold is applied. CONCLUSION: The refinement of the dose calculation to the nanometer scale has revealed important differences in the energy deposition between high- and low-LET ions. Voxels of very high dose are only found in the path of high-LET ions. Interestingly, experiments have shown that DSB induced by high-LET radiation are more difficult to repair. Therefore, this new approach may be useful to understand the nature of DSB and oxidative damage induced by ionizing radiation.
Response of Intestinal Bacterial Flora to the Long-term Feeding of Aflatoxin B1 (AFB1) in Mice.
Yang, Xiai; Liu, Liangliang; Chen, Jing; Xiao, Aiping
2017-10-12
In order to investigate the influence of aflatoxin B1 (AFB1) on intestinal bacterial flora, 24 Kunming mice (KM mice) were randomly placed into four groups, which were labeled as control, low-dose, medium-dose, and high-dose groups. They were fed intragastrically with 0.4 mL of 0 mg/L, 2.5 mg/L, 4 mg/L, or 10 mg/L of AFB1 solutions, twice a day for 2 months. The hypervariable region V3 + V4 on 16S rDNA of intestinal bacterial flora was sequenced by the use of a high-flux sequencing system on a Miseq Illumina platform; then, the obtained sequences were analyzed. The results showed that, when compared with the control group, both genera and phyla of intestinal bacteria in the three treatment groups decreased. About one third of the total genera and one half of the total phyla remained in the high-dose group. The dominant flora were Lactobacillus and Bacteroides in all groups. There were significant differences in the relative abundance of intestinal bacterial flora among groups. Most bacteria decreased as a whole from the control to the high-dose groups, but several beneficial and pathogenic bacterial species increased significantly with increasing dose of AFB1. Thus, the conclusion was that intragastric feeding with 2.5~10 mg/mL AFB1 for 2 months could decrease the majority of intestinal bacterial flora and induce the proliferation of some intestinal bacteria flora.
Kaplovitch, Eric; Gomes, Tara; Camacho, Ximena; Dhalla, Irfan A.; Mamdani, Muhammad M.; Juurlink, David N.
2015-01-01
Background The use of opioids for noncancer pain is widespread, and more than 16,000 die of opioid-related causes in the United States annually. The patients at greatest risk of death are those receiving high doses of opioids. Whether sex influences the risk of dose escalation or opioid-related mortality is unknown. Methods and Findings We conducted a cohort study using healthcare records of 32,499 individuals aged 15 to 64 who commenced chronic opioid therapy for noncancer pain between April 1, 1997 and December 31, 2010 in Ontario, Canada. Patients were followed from their first opioid prescription until discontinuation of therapy, death from any cause or the end of the study period. Among patients receiving chronic opioid therapy, 589 (1.8%) escalated to high dose therapy and n = 59 (0.2%) died of opioid-related causes while on treatment. After multivariable adjustment, men were more likely than women to escalate to high-dose opioid therapy (adjusted hazard ratio 1.44; 95% confidence interval 1.21 to 1.70) and twice as likely to die of opioid-related causes (adjusted hazard ratio 2.04; 95% confidence interval 1.18 to 3.53). These associations were maintained in a secondary analysis of 285,520 individuals receiving any opioid regardless of the duration of therapy. Conclusions Men are at higher risk than women for escalation to high-dose opioid therapy and death from opioid-related causes. Both outcomes were more common than anticipated. PMID:26291716
NASA Technical Reports Server (NTRS)
George, K. A.; Hada, M.; Patel, Z.; Huff, J.; Pluth, J. M.; Cucinotta, F. A.
2009-01-01
Chromosome aberration yields were assessed in DNA double-strand break repair (DSB) deficient cells after acute doses of gamma-rays or high-LET iron nuclei, or low dose-rate (0.018 Gy/hr) gamma-rays. We studied several cell lines including fibroblasts deficient in ATM (product of the gene that is mutated in ataxia telangiectasia patients) or NBS (product of the gene mutated in the Nijmegen breakage syndrome), and gliomablastoma cells that are proficient or lacking in DNA-dependent protein kinase, DNA-PK activity. Chromosomes were analyzed using the fluorescence in-situ hybridization (FISH) chromosome painting method in cells at the first division post-irradiation and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). Gamma radiation induced higher yields of both simple and complex exchanges in the DSB repair defective cells than in the normal cells. The quadratic dose-response terms for both chromosome exchange types were significantly higher for the ATM and NBS defective lines than for normal fibroblasts. However, the linear dose-response term was significantly higher only for simple exchanges in the NBS cells. Large increases in the quadratic dose response terms indicate the important roles of ATM and NBS in chromatin modifications that facilitate correct DSB repair and minimize aberration formation. Differences in the response of AT and NBS deficient cells at lower doses suggests important questions about the applicability of observations of radiation sensitivity at high dose to low dose exposures. For all iron nuclei irradiated cells, regression models preferred purely linear and quadratic dose responses for simple and complex exchanges, respectively. All the DNA repair defective cell lines had lower Relative biological effectiveness (RBE) values than normal cells, the lowest being for the DNA-PK-deficient cells, which was near unity. To further investigate the sensitivity differences for low and low high doses, we performed chronic low dose-rate irradiation, and have begun studies with ATM and Nibrin inhibitors and siRNA knockout of these proteins. Results support the conclusion that for the endpoint of simple chromosomal aberrations (translocation or dicentrics), the increased radiation sensitivity of AT cells found at high doses (>1 Gy) does not carry over to low doses or doserates, while NBS cells show increased sensitivity for both high and low dose exposures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diez, Patricia; Vogelius, Ivan S.; Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792
2010-07-15
Purpose: A new method is presented for synthesizing dose-response data for biochemical control of prostate cancer according to study design (randomized vs. nonrandomized) and risk group (low vs. intermediate-high). Methods and Materials: Nine published prostate cancer dose escalation studies including 6,539 patients were identified in the MEDLINE and CINAHL databases and reviewed to assess the relationship between dose and biochemical control. A novel method of analysis is presented in which the normalized dose-response gradient, {gamma}{sub 50}, is estimated for each study and subsequently synthesized across studies. Our method does not assume that biochemical control rates are directly comparable between studies.more » Results: Nonrandomized studies produced a statistically significantly higher {gamma}{sub 50} than randomized studies for intermediate- to high-risk patients ({gamma}{sub 50} = 1.63 vs. {gamma}{sub 50} = 0.93, p = 0.03) and a borderline significantly higher ({gamma}{sub 50} = 1.78 vs. {gamma}{sub 50} = 0.56, p = 0.08) for low-risk patients. No statistically significant difference in {gamma}{sub 50} was found between low- and intermediate- to high-risk patients (p = 0.31). From the pooled data of low and intermediate- to high-risk patients in randomized trials, we obtain the overall best estimate of {gamma}{sub 50} = 0.84 with 95% confidence interval 0.54-1.15. Conclusions: Nonrandomized studies overestimate the steepness of the dose-response curve as compared with randomized trials. This is probably the result of stage migration, improved treatment techniques, and a shorter follow-up in higher dose patients that were typically entered more recently. This overestimation leads to inflated expectations regarding the benefit from dose-escalation and could lead to underpowered clinical trials. There is no evidence of a steeper dose response for intermediate- to high-risk compared with low-risk patients.« less
Steinmann, Peter; Utzinger, Jürg; Du, Zun-Wei; Jiang, Jin-Yong; Chen, Jia-Xu; Hattendorf, Jan; Zhou, Hui; Zhou, Xiao-Nong
2011-01-01
Background The control of soil-transmitted helminth (STH) infections currently relies on the large-scale administration of single-dose oral albendazole or mebendazole. However, these treatment regimens have limited efficacy against hookworm and Trichuris trichiura in terms of cure rates (CR), whereas fecal egg reduction rates (ERR) are generally high for all common STH species. We compared the efficacy of single-dose versus triple-dose treatment against hookworm and other STHs in a community-based randomized controlled trial in the People's Republic of China. Methodology/Principal findings The hookworm CR and fecal ERR were assessed in 314 individuals aged ≥5 years who submitted two stool samples before and 3–4 weeks after administration of single-dose oral albendazole (400 mg) or mebendazole (500 mg) or triple-dose albendazole (3×400 mg over 3 consecutive days) or mebendazole (3×500 mg over 3 consecutive days). Efficacy against T. trichiura, Ascaris lumbricoides, and Taenia spp. was also assessed. Albendazole cured significantly more hookworm infections than mebendazole in both treatment regimens (single dose: respective CRs 69% (95% confidence interval [CI]: 55–81%) and 29% (95% CI: 20–45%); triple dose: respective CRs 92% (95% CI: 81–98%) and 54% (95% CI: 46–71%)). ERRs followed the same pattern (single dose: 97% versus 84%; triple dose: 99.7% versus 96%). Triple-dose regimens outperformed single doses against T. trichiura; three doses of mebendazole – the most efficacious treatment tested – cured 71% (95% CI: 57–82%). Both single and triple doses of either drug were highly efficacious against A. lumbricoides (CR: 93–97%; ERR: all >99.9%). Triple dose regimens cured all Taenia spp. infections, whereas single dose applications cured only half of them. Conclusions/Significance Single-dose oral albendazole is more efficacious against hookworm than mebendazole. To achieve high CRs against both hookworm and T. trichiura, triple-dose regimens are warranted. Trial Registration www.controlled-trials.com ISRCTN47375023 PMID:21980373
Poster - 36: Effect of Planning Target Volume Coverage on the Dose Delivered in Lung Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dekker, Chris; Wierzbicki, Marcin
2016-08-15
Purpose: In lung radiotherapy, breathing motion may be encompassed by contouring the internal target volume (ITV). Remaining uncertainties are included in a geometrical expansion to the planning target volume (PTV). In IMRT, the treatment is then optimized until a desired PTV fraction is covered by the appropriate dose. The resulting beams often carry high fluence in the PTV margin to overcome low lung density and to generate steep dose gradients. During treatment, the high density tumour can enter the PTV margin, potentially increasing target dose. Thus, planning lung IMRT with a reduced PTV dose may still achieve the desired ITVmore » dose during treatment. Methods: A retrospective analysis was carried out with 25 IMRT plans prescribed to 63 Gy in 30 fractions. The plans were re-normalized to cover various fractions of the PTV by different isodose lines. For each case, the isocentre was moved using 125 shifts derived from all 3D combinations of 0 mm, (PTV margin - 1 mm), and PTV margin. After each shift, the dose was recomputed to approximate the delivered dose. Results and Conclusion: Our plans typically cover 95% of the PTV by 95% of the dose. Reducing the PTV covered to 94% did not significantly reduce the delivered ITV doses for (PTV margin - 1 mm) shifts. Target doses were reduced significantly for all other shifts and planning goals studied. Thus, a reduced planning goal will likely deliver the desired target dose as long as the ITV rarely enters the last mm of the PTV margin.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Utsunomiya, S; Kushima, N; Katsura, K
Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cmmore » × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.« less
Wang, Xu; Huang, Xian-Ju; Ihsan, Awais; Liu, Zhao-Ying; Huang, Ling-Li; Zhang, Hua-Hai; Zhang, Hong-Fei; Zhou, Wen; Liu, Qin; Xue, Xi-Juan; Yuan, Zong-Hui
2011-02-27
Mequindox (MEQ) is a novel synthetic quinoxaline 1,4-dioxides antibacterial agent and growth promoter in animal husbandry. This study was to investigate whether reactive oxygen species (ROS), the Janus kinase-signal transducer and activator of transcription (JAK/STAT) pathway, suppressors of cytokine signaling (SOCS) and inflammatory cytokines were involved in toxicities of MEQ. Our data demonstrated that high dose of MEQ (275 mg/kg) apparently led to tissue impairment combined with imbalance of redox in liver. In liver and spleen samples, hydroxylation metabolites and desoxymequindox were detected, directly confirming the potential link of N→O group reduction metabolism with its organ toxicity. Moreover, up-regulation of JAK/STAT, SOCS family, tumor necrosis factor (TNF-α) and interleukin-6 (IL-6) were also observed in the high-dose group. Meanwhile, significant changes of oxidative stress indices in liver were observed in the high-dose group. As for NADPH subunit, the mRNA levels of many subunits were significantly up-regulated at low doses but down-regulated in a dose-dependent manner in liver and spleen, suggesting an involvement of NADPH in MEQ metabolism and ROS generation. In conclusion, we reported the dose-dependent long-term toxicity as well as the discussion of the potential mechanism and pathways of MEQ, which raised further awareness of its toxicity following with the dose change. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uehara, R; Tachibana, H
Purpose: There have been several publications focusing on dose calculation in lung for a new dose calculation algorithm of Acuros XB (AXB). AXB could contribute to dose calculation for high-density media for bone and dental prosthesis rather than in lung. We compared the dosimetric performance of AXB, Adaptive Convolve (AC) in head and neck IMRT plans. Methods: In a phantom study, the difference in depth profile between AXB and AC was evaluated using Kodak EDR2 film sandwiched with tough water phantoms. 6 MV x-ray using the TrueBeam was irradiated. In a patient study, 20 head and neck IMRT plans hadmore » been clinically approved in Pinnacle3 and were transferred to Eclipse. Dose distribution was recalculated using AXB in Eclipse while maintaining AC-calculated monitor units and MLC sequence planned in Pinnacle. Subsequently, both the dose-volumetric data obtained using the two different calculation algorithms were compared. Results: The results in the phantom evaluation for the shallow area ahead of the build-up region shows over-dose for AXB and under-dose for AC, respectively. In the patient plans, AXB shows more hot spots especially around the high-density media than AC in terms of PTV (Max difference: 4.0%) and OAR (Max. difference: 1.9%). Compared to AC, there were larger dose deviations in steep dose gradient region and higher skin-dose. Conclusion: In head and neck IMRT plans, AXB and AC show different dosimetric performance for the regions inside the target volume around high-density media, steep dose gradient regions and skin-surface. There are limitations in skin-dose and complex anatomic condition using even inhomogeneous anthropomorphic phantom Thus, there is the potential for an increase of hot-spot in AXB, and an underestimation of dose in substance boundaries and skin regions in AC.« less
Post, Jacob; Weesendorp, Eefke; Montoya, Maria; Loeffen, Willie L
African swine fever (ASF) is a fatal disease for domestic pigs, leading to serious economic losses in countries where ASF is endemic. Despite extensive research, efficient vaccines against ASF are lacking. Since peripheral blood cells are important mediators for vaccines, we study the impact of ASF on blood parameters in pigs with different ages and infected with different doses of ASF virus. Four different groups were studied: (1) 12 weeks of age/low virus dose; (2) 12 weeks of age/high virus dose; (3) 18 weeks of age/low virus dose; and (4) 18 weeks of age/high virus dose. By varying in age and/or ASFV inoculation dose, we monitor blood parameters during different degrees of disease. Thirty percent of the pigs survived the infection with a moderately virulent strain of African swine fever virus (ASFV). Animals that did survive infection were generally older, independent from the inoculation dose used. A firm reduction in many different cell types at 3-5 days postinfection (DPI) was accompanied by an increase in body temperature, followed by clinical signs and mortality from day 6 PI. While blood parameters generally normalized in survivors, γδ T cells and IL-10 levels could be related to mortality. These conclusions should be considered in new approaches for protection against ASF.
Ruiz-Irastorza, G; Garcia, M; Espinosa, G; Caminal, L; Mitjavila, F; González-León, R; Sopeña, B; Canora, J; Villalba, M V; Rodríguez-Carballeira, M; López-Dupla, J M; Callejas, J L; Castro, A; Tolosa, C; Sánchez-García, M E; Pérez-Conesa, M; Navarrete-Navarrete, N; Rodríguez, A P; Herranz, M T; Pallarés, L
2016-01-01
Aim To study the influence of prednisone dose during the first month after systemic lupus erythematosus (SLE) diagnosis (prednisone-1) on glucocorticoid burden during the subsequent 11 months (prednisone-2–12). Methods 223 patients from the Registro Español de Lupus Eritematoso Sistémico inception cohort were studied. The cumulative dose of prednisone-1 and prednisone-2–12 were calculated and recoded into a four-level categorical variable: no prednisone, low dose (up to 7.5 mg/day), medium dose (up to 30 mg/day) and high dose (over 30 mg/day). The association between the cumulative prednisone-1 and prednisone-2–12 doses was tested. We analysed whether the four-level prednisone-1 categorical variable was an independent predictor of an average dose >7.5 mg/day of prednisone-2–12. Adjusting variables included age, immunosuppressives, antimalarials, methyl-prednisolone pulses, lupus nephritis and baseline SLE Disease Activity Index (SLEDAI). Results Within the first month, 113 patients (51%) did not receive any prednisone, 24 patients (11%) received average low doses, 46 patients (21%) received medium doses and 40 patients (18%) received high doses. There was a strong association between prednisone-1 and prednisone-2–12 dose categories (p<0.001). The cumulative prednisone-1 dose was directly associated with the cumulative prednisone-2–12 dose (p<0.001). Compared with patients on no prednisone, patients taking medium (adjusted OR 5.27, 95% CI 2.18 to 12.73) or high-dose prednisone-1 (adjusted OR 10.5, 95% CI 3.8 to 29.17) were more likely to receive prednisone-2–12 doses of >7.5 mg/day, while patients receiving low-dose prednisone-1 were not (adjusted OR 1.4, 95% CI 0. 0.38 to 5.2). If the analysis was restricted to the 158 patients with a baseline SLEDAI of ≥6, the model did not change. Conclusion The dose of prednisone during the first month after the diagnosis of SLE is an independent predictor of prednisone burden during the following 11 months. PMID:27547439
Barker, D. P.; Simpson, J.; Pawula, M.; Barrett, D. A.; Shaw, P. N.; Rutter, N.
1995-01-01
AIMS--To compare the safety and efficacy of two loading doses of diamorphine in 27 ventilated newborn infants in a randomised double blind trial. METHODS--Fifty or 200 mcg/kg were infused intravenously over 30 minutes, followed by a 15 mcg/kg/hour continuous infusion. Serial measurements were made of physiology, behaviour, and stress hormones. RESULTS--Both loading doses produced small but significant falls in blood pressure. The 200 mcg/kg dose produced greater respiratory depression, and two infants deteriorated clinically, requiring resuscitation. Loading reduced respiratory effort in most of the infants, but had little effect on behavioural activity. Stress hormone concentrations were reduced at six hours in both dosage groups; differences between loading doses were not significant. Morphine, morphine-3-glucuronide, and morphine-6-glucuronide were detected in the plasma of all patients. No significant differences in concentrations between loading doses were found. CONCLUSIONS--Diamorphine reduces the stress response in ventilated newborn infants. A high loading dose confers no benefit, and may produce undesirable physiological effects. A 50 mcg/kg loading dose seems to be safe and effective. PMID:7552591
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding
2012-08-15
Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receivingmore » a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.« less
Clinical trial of an inhibitor of RAGE-Aβ interactions in Alzheimer disease.
Galasko, Douglas; Bell, Joanne; Mancuso, Jessica Y; Kupiec, James W; Sabbagh, Marwan N; van Dyck, Christopher; Thomas, Ronald G; Aisen, Paul S
2014-04-29
To examine safety, tolerability, and efficacy of PF-04494700, an inhibitor of the receptor for advanced glycation end products (RAGE), in mild to moderate Alzheimer disease (AD). Double-blind, placebo-controlled trial at 40 academic centers (United States). Subjects with AD and Mini-Mental State Examination score 14-26 were randomized to PF-04494700 60 mg/day × 6 days, then 20 mg daily (high dose); 15 mg/day × 6 days, then 5 mg daily (low dose); or placebo, for 18 months. Clinical and laboratory measures were used to evaluate safety and tolerability. The primary efficacy measure was the Alzheimer's Disease Assessment Scale-cognitive (ADAS-cog). Secondary measures assessed clinical stage, function, behavior, MRI, and CSF biomarkers. A total of 399 subjects were randomized. In a prespecified interim analysis, when 50% of subjects had completed the 6-month visit, the high dose was associated with confusion, falls, and greater ADAS-cog decline and was discontinued. A second prespecified analysis compared low-dose and placebo groups for futility and safety approximately 12 months after all subjects were randomized. This analysis met criteria for futility, and treatment was discontinued. There were no safety concerns in the low-dose group. Analyses including post-futility data showed decreased decline on the ADAS-cog in the low-dose group at month 18. Other clinical and biomarker measures showed no differences between low-dose treatment and placebo. PF-04494700 at 20 mg/d was associated with increased adverse events and cognitive decline. At 5 mg/d, PF-04494700 had a good safety profile. A potential benefit for this low dose on the ADAS-cog is not conclusive, because of high dropout and discontinuation rates subsequent to the interim analyses. This study provides Class I evidence that in patients with AD high-dose PF-04494700 increased cognitive decline at 6 months and Class IV evidence that low-dose PF-04494700 slowed cognitive decline at 18 months.
Use of gadoxetic acid for computed tomographic cholangiography in healthy dogs.
Chau, Jennifer; Podadera, Juan M; Young, Alex C; Makara, Mariano A
2017-07-01
OBJECTIVE To evaluate the effect of gadoxetic acid (contrast) dose on biliary tract enhancement, determine the optimal time after contrast injection for CT image acquisition, and assess the feasibility of CT cholangiography in sedated dogs. ANIMALS 8 healthy dogs. PROCEDURES The study had 2 parts. In part 1, 4 dogs were anesthetized and underwent CT cholangiography twice. Gadoxetic acid was administered IV at a low dose (0.025 mmol/kg) for the first procedure and high dose (0.3 mmol/kg) for the second procedure. Serial CT scans were obtained at predetermined times after contrast injection. In part 2, 4 dogs were sedated and underwent CT angiography 85 minutes after IV administration of the high contrast dose. Contrast enhancement of the biliary tract on all scans was objectively assessed by measurement of CT attenuation and qualitatively assessed by use of a subjective 4-point scoring system by 3 independent reviewers. All measurements were compared over time and between contrast doses for the dogs of part 1. Subjective measurements were compared between the sedated dogs of part 2 and anesthetized dogs of part 1. RESULTS Enhancement of the biliary tract was positively associated with contrast dose and time after contrast injection. Optimal enhancement was achieved 65 minutes after contrast injection. Subjective visualization of most biliary structures did not differ significantly between sedated and anesthetized dogs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated CT cholangiography with gadoxetic acid was feasible in sedated dogs. The high contrast dose provided better visualization of biliary structures than the low dose; CT scans should be obtained 65 minutes after contrast injection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, L; Ding, G
Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millenniummore » 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.« less
Moore, Christopher L.; Daniels, Brock; Singh, Dinesh; Luty, Seth; Gunabushanam, Gowthaman; Ghita, Monica; Molinaro, Annette; Gross, Cary P.
2016-01-01
Purpose To determine if a reduced-dose computed tomography (CT) protocol could effectively help to identify patients in the emergency department (ED) with moderate to high likelihood of calculi who would require urologic intervention within 90 days. Materials and Methods The study was approved by the institutional review board and written informed consent with HIPAA authorization was obtained. This was a prospective, single-center study of patients in the ED with moderate to high likelihood of ureteral stone undergoing CT imaging. Objective likelihood of ureteral stone was determined by using the previously derived and validated STONE clinical prediction rule, which includes five elements: sex, timing, origin, nausea, and erythrocytes. All patients with high STONE score (STONE score, 10–13) underwent reduced-dose CT, while those with moderate likelihood of ureteral stone (moderate STONE score, 6–9) underwent reduced-dose CT or standard CT based on clinician discretion. Patients were followed to 90 days after initial imaging for clinical course and for the primary outcome of any intervention. Statistics are primarily descriptive and are reported as percentages, sensitivities, and specificities with 95% confidence intervals. Results There were 264 participants enrolled and 165 reduced-dose CTs performed; of these participants, 108 underwent reduced-dose CT alone with complete follow-up. Overall, 46 of 264 (17.4%) of patients underwent urologic intervention, and 25 of 108 (23.1%) patients who underwent reduced-dose CT underwent a urologic intervention; all were correctly diagnosed on the clinical report of the reduced-dose CT (sensitivity, 100%; 95% confidence interval: 86.7%, 100%). The average dose-length product for all standard-dose CTs was 857 mGy · cm ± 395 compared with 101 mGy · cm ± 39 for all reduced-dose CTs (average dose reduction, 88.2%). There were five interventions for nonurologic causes, three of which were urgent and none of which were missed when reduced-dose CT was performed. Conclusion A CT protocol with over 85% dose reduction can be used in patients with moderate to high likelihood of ureteral stone to safely and effectively identify patients in the ED who will require urologic intervention. PMID:26943230
Taxonomic and developmental aspects of radiosensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, F.L.; Anderson, S.L.
1996-11-01
Considerable information is available on the effects of radioactivity on adult and early life stages of organisms. The preponderance of data is on mortality after a single irradiation with relatively high doses. Unfortunately, because experiments were carried out under different conditions and for different time periods, the validity of comparing the results from different laxonomic groups is questionable. In general, the conclusions are that there is a relationship (1) between radioresistance to high doses of acute radiation and taxonomy of the organism, primitive forms being more radioresistant than complex vertebrates and (2) between radiosensitivity and developmental stage, early life stagesmore » being more sensitive than later stages. The first conclusion may be related to the capability of the organism to repopulate cells and to differentiate and redifferentiate them; the second to the rate of cellular division and to the degree of differentiation. In question, however, is the relevance of the responses from high levels of acute radiation to that of the responses to long-term exposure to low levels of radiation, which are ecologically of more interest. Data from studies of the effects of acute and chronic exposure on development of gametes and zygotes indicate that, for some fishes and invertebrates, responses at the cellular and molecular levels show effect levels comparable to those observed in some mammals. Acute doses between 0,05 and 0.5Cy and dose rates between 0.02 to 0.2mCy/h appear to define critical ranges in which detrimental effects on fertility are first observed in a variety of radiosensitive organisms. To better understand inherent radiosensitivity, we need more information on the ability of cells to repopulate and differentiate and to prevent or repair damage to biological critical molecules, such as DNA, because these factors may alter significantly organisms` responses to radiation.« less
Luhovyy, Bohdan L; Mollard, Rebecca C; Yurchenko, Svitlana; Nunez, Maria Fernanda; Berengut, Shari; Liu, Ting Ting; Smith, Christopher E; Pelkman, Christine L; Anderson, G Harvey
2014-12-01
The objective of this study was to determine the dose response effect of whole grain high-amylose maize (HAM) flour as a source of resistant starch (RS) on blood glucose, appetite and short-term food intake. In a repeated-measures crossover trial, healthy men (n = 30, 22.9 ± 0.6 y, BMI of 22.6 ± 0.3 kg/m(2)) were randomly assigned to consume 1 of 3 cookies once a week for 3 wk. Cookies were control (100% wheat flour), low-dose (63% wheat flour,37% HAM flour), and high-dose (33% wheat flour, 67% HAM flour) providing 53.5, 43.5, and 36.3 g of available carbohydrate, respectively. Ad libitum food intake was measured 120 min at a pizza meal, blood glucose and subjective appetite were measured after consumption of the cookie (0 to 120 min) and after the pizza meal (140 to 200 min). Blood glucose concentrations were lower at 30 and 45 min after high-dose treatment, and at 120 min after both high- and low-dose treatments compared to control (P < 0.05). Blood glucose AUC before the pizza meal (0 to 120 min) was 44% and 14% lower, and higher by 43% and 41% after the pizza meal (140 to 200 min) compared with control. Yet despite the higher response following the meal, cumulative AUC (0 to 200 min) was still 22% lower after the high-dose treatment (P < 0.05). All treatments equally suppressed subjective appetite and there was no effect on food intake. In conclusion, HAM flour as a source of RS and incorporated into a cookie was associated with better glycemic control in young men. © 2014 Institute of Food Technologists®
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hrycushko, Brian A.; Li Shihong; Shi Chengyu
2011-03-01
Purpose: The primary objective was to investigate a novel focal brachytherapy technique using lipid nanoparticle (liposome)-carried {beta}-emitting radionuclides (rhenium-186 [{sup 186}Re]/rhenium-188 [{sup 188}Re]) to simultaneously treat the postlumpectomy surgical cavity and draining lymph nodes. Methods and Materials: Cumulative activity distributions in the lumpectomy cavity and lymph nodes were extrapolated from small animal imaging and human lymphoscintigraphy data. Absorbed dose calculations were performed for lumpectomy cavities with spherical and ellipsoidal shapes and lymph nodes within human subjects by use of the dose point kernel convolution method. Results: Dose calculations showed that therapeutic dose levels within the lumpectomy cavity wall can covermore » 2- and 5-mm depths for {sup 186}Re and {sup 188}Re liposomes, respectively. The absorbed doses at 1 cm sharply decreased to only 1.3% to 3.7% of the doses at 2 mm for {sup 186}Re liposomes and 5 mm for {sup 188}Re liposomes. Concurrently, the draining sentinel lymph nodes would receive a high focal therapeutic absorbed dose, whereas the average dose to 1 cm of surrounding tissue received less than 1% of that within the nodes. Conclusions: Focal brachytherapy by use of {sup 186}Re/{sup 188}Re liposomes was theoretically shown to be capable of simultaneously treating the lumpectomy cavity wall and draining sentinel lymph nodes with high absorbed doses while significantly lowering dose to surrounding healthy tissue. In turn, this allows for dose escalation to regions of higher probability of containing residual tumor cells after lumpectomy while reducing normal tissue complications.« less
Psychopharmacology of theobromine in healthy volunteers
Baggott, Matthew J.; Childs, Emma; Hart, Amy B.; de Bruin, Eveline; Palmer, Abraham A.; Wilkinson, Joy E.; de Wit, Harriet
2013-01-01
Background Theobromine, a methylxanthine related to caffeine and present in high levels in cocoa, may contribute to the appeal of chocolate. However, currently evidence for this is limited. Objectives We conducted a within-subjects placebo-controlled study of a wide range of oral theobromine doses (250, 500, and 1000 mg) using an active control dose of caffeine (200 mg) in 80 healthy participants. Results Caffeine had the expected effects on mood including feelings of alertness, and cardiovascular parameters. Theobromine responses differed according to dose: it showed limited subjective effects at 250 mg and negative mood effects at higher doses. It also dose-dependently increased heart rate. In secondary analyses we also examined individual differences in the drugs' effects in relation to genes related to their target receptors, but few associations were detected. Conclusions This study represents the highest dose of theobromine studied in humans. We conclude that theobromine at normal intake ranges may contribute to the positive effects of chocolate, but at higher intakes effects become negative. PMID:23420115
2013-01-01
Background We measured and assessed ways to reduce the secondary neutron dose from a system for proton eye treatment. Methods Proton beams of 60.30 MeV were delivered through an eye-treatment snout in passive scattering mode. Allyl diglycol carbonate (CR-39) etch detectors were used to measure the neutron dose in the external field at 0.00, 1.64, and 6.00 cm depths in a water phantom. Secondary neutron doses were measured and compared between those with and without a high-hydrogen–boron-containing block. In addition, the neutron energy and vertices distribution were obtained by using a Geant4 Monte Carlo simulation. Results The ratio of the maximum neutron dose equivalent to the proton absorbed dose (H(10)/D) at 2.00 cm from the beam field edge was 8.79 ± 1.28 mSv/Gy. The ratio of the neutron dose equivalent to the proton absorbed dose with and without a high hydrogen-boron containing block was 0.63 ± 0.06 to 1.15 ± 0.13 mSv/Gy at 2.00 cm from the edge of the field at depths of 0.00, 1.64, and 6.00 cm. Conclusions We found that the out-of-field secondary neutron dose in proton eye treatment with an eye snout is relatively small, and it can be further reduced by installing a borated neutron absorbing material. PMID:23866307
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Y M; Bush, K; Han, B
Purpose: Accurate and fast dose calculation is a prerequisite of precision radiation therapy in modern photon and particle therapy. While Monte Carlo (MC) dose calculation provides high dosimetric accuracy, the drastically increased computational time hinders its routine use. Deterministic dose calculation methods are fast, but problematic in the presence of tissue density inhomogeneity. We leverage the useful features of deterministic methods and MC to develop a hybrid dose calculation platform with autonomous utilization of MC and deterministic calculation depending on the local geometry, for optimal accuracy and speed. Methods: Our platform utilizes a Geant4 based “localized Monte Carlo” (LMC) methodmore » that isolates MC dose calculations only to volumes that have potential for dosimetric inaccuracy. In our approach, additional structures are created encompassing heterogeneous volumes. Deterministic methods calculate dose and energy fluence up to the volume surfaces, where the energy fluence distribution is sampled into discrete histories and transported using MC. Histories exiting the volume are converted back into energy fluence, and transported deterministically. By matching boundary conditions at both interfaces, deterministic dose calculation account for dose perturbations “downstream” of localized heterogeneities. Hybrid dose calculation was performed for water and anthropomorphic phantoms. Results: We achieved <1% agreement between deterministic and MC calculations in the water benchmark for photon and proton beams, and dose differences of 2%–15% could be observed in heterogeneous phantoms. The saving in computational time (a factor ∼4–7 compared to a full Monte Carlo dose calculation) was found to be approximately proportional to the volume of the heterogeneous region. Conclusion: Our hybrid dose calculation approach takes advantage of the computational efficiency of deterministic method and accuracy of MC, providing a practical tool for high performance dose calculation in modern RT. The approach is generalizable to all modalities where heterogeneities play a large role, notably particle therapy.« less
Exercise and the heart--the harm of too little and too much.
Lavie, Carl J; O'Keefe, James H; Sallis, Robert E
2015-01-01
Physical activity and exercise training are underutilized by much of Westernized society, and physical inactivity may be the greatest threat to health in the 21st century. Many studies have shown a linear relationship between one's activity level and heart health, leading to the conclusion that "if some exercise is good, more must be better." However, there is evolving evidence that high levels of exercise may produce similar or less overall cardiovascular (CV) benefits compared with those produced by lower doses of exercise. Very high doses of exercise may be associated with increased risk of atrial fibrillation, coronary artery disease, and malignant ventricular arrhythmias. These acute bouts of excessive exercise may lead to cardiac dilatation, cardiac dysfunction, and release of troponin and brain natriuretic peptide. The effects of too little and too much exercise on the heart are reviewed in this article, along with recommendations to optimize the dose of exercise to achieve heart health.
2014-01-01
Background Unintended pregnancy is a complex phenomenon which raise to take an emergency decision. Low contraceptive prevalence and high user failure rates are the leading causes of this unexpected situation. High user failure rates suggest the vital role of emergency contraception to prevent unplanned pregnancy. Levonorgestrel - a commonly used progestin for emergency contraception. However, little is known about its pharmacokinetics and optimal dose for use. Hence, there is a need to conduct a systematic review of the available evidences. Methods Randomized, double-blind trials were sought, evaluating healthy women with regular menstrual cycles, who requested emergency contraception within 72 h of unprotected coitus, to one of three regimens: 1.5 mg single dose levonorgestrel, two doses of 0.75 mg levonorgestrel given 12 h apart or two doses of 0.75 mg levonorgestrel given 24 h apart. The primary outcome was unintended pregnancy; other outcomes were side-effects and timing of next menstruation. Results Every trial under consideration successfully established the contraceptive effectiveness of levonorgestrel for preventing unintended pregnancy. Moreover, a single dose of levonorgestrel 1.5 mg for emergency contraception supports its safety and efficacy profile. If two doses of levonorgestrel 0.75 mg are intended for administration, the second dose can positively be taken 12–24 h after the first dose without compromising its contraceptive efficacy. The main side effect was frequent menstrual irregularities. No serious adverse events were reported. Conclusions The review shows that, emergency contraceptive regimen of single-dose levonorgestrel is not inferior in efficacy to the two-dose regimen. All the regimens studied were very efficacious for emergency contraception and prevented a high proportion of pregnancies if taken within 72 h of unprotected coitus. Single levonorgestrel dose (1.5 mg) can substitute two 0.75 mg doses 12 or 24 h apart. With either regimen, the earlier the treatment is given, the more effective it seems to be. PMID:24708837
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu Wei, E-mail: dr-lw@163.com; Li Yanhao, E-mail: liyanhao@fimmu.com; He Xiaofeng
Our purpose was to study necrosis and apoptosis of hepatocellular carcinoma (HCC) cells after preoperative transcatheter arterial chemoembolization (TACE) with use of low-dose and high-dose anticancer drugs in HCCs. Fifty-four patients with advanced but surgically resectable HCC were studied. Thirty-four patients who elected to undergo preoperative superselective TACE were randomized to low- and high-dose TACE. Patients in group A (n = 16) received low-dose anticancer drugs: 2 mg mitomycin C (MMC), 10 mg epirubicin (EPI), and 100 mg carboplatin (CBP). Patients in group B (n = 18) were given high doses of anticancer drugs (10 mg MMC, 40 mg EPI,more » and 300 mg CBP). Hepatic resection was subsequently performed. Group C comprised 20 patients who underwent resection without TACE. In all patients the necrosis rates and apoptosis index of tumor cells were evaluated by pathologic examinations and terminal deoxynucleotidyl transferase-mediated nick-end labeling assay. There was no significant difference between group A and group B in tumor response (p > 0.05) after TACE. Necrosis rates in groups A, B, and C were 88.4 {+-} 11.1%, 87.1 {+-} 12.5%, and 7.3 {+-} 3.5%, respectively. There was no significant difference between group A and group B (p > 0.05), while statistical difference was found between group A and group C (p < 0.001) and between group B and group C (p < 0.001). Apoptosis indexes in the three groups were 11.0 {+-} 4.0%, 10.7 {+-} 3.9%, and 5.6 {+-} 2.6%, respectively. Statistical difference exhibited between group A and group C (p < 0.001) and group B versus group C (p < 0.001). No significant difference was observed between group A and group B (p > 0.05). In conclusion, superselective TACE with low- and high-dose chemotherapeutic agents induced similar degrees of cellular apoptosis and necrosis.« less
Efficacy of short-term moderate or high-dose rosuvastatin in preventing contrast-induced nephropathy
Liang, Min; Yang, Shicheng; Fu, Naikuan
2017-01-01
Abstract Background: The prophylactic efficacy of statin pretreatment for the prevention of contrast-induced nephropathy (CIN) in patients undergoing coronary angiography (CAG) or percutaneous coronary intervention (PCI) remains controversial. The aim of the study was to perform a meta-analysis of randomized controlled trials (RCTs) to assess the effectiveness of short-term moderate or high-dose rosuvastatin pretreatment in preventing CIN. Methods: We included RCTs comparing short-term moderate or high-dose rosuvastatin treatment versus low-dose rosuvastatin treatment or placebo for preventing CIN. The primary endpoint was the incidence of CIN within 2 to 5 days after contrast administration, and related-parameters including serum creatinine (SCr), cystatin C (CysC), hypersensitive C-reactive protein (hs-CRP), urine microalbumin (mALB) were also extracted. Results: Fifteen RCTs with a total of 2673 patients were identified and analyzed. Patients who received moderate or high-dose rosuvastatin pretreatment had a 55% lower risk of CIN compared with low-dose rosuvastatin pretreatment or placebo group based on a fixed effect model (RR = 0.45, 95% CI 0.35–0.58, P < .0001). The benefit of moderate or high-dose rosuvastatin was consistent in both comparisons with low-dose rosuvastatin (RR = 0.40, 95% CI 0.27–0.59, P < .0001) or placebo (RR = 0.45, 95% CI 0.35–0.58, P < .0001). And moderate (20 mg) or high dose (≥40 mg) rosuvastatin significantly reduced the incidence of CIN compared with the control (RR = 0.39, 95% CI 0.29–0.54, P < .0001, RR = 0.56, 95% CI 0.37–0.85, P = .006, respectively). Subgroup analysis showed that moderate or high-dose rosuvastatin pretreatment could decrease the incidence of CIN in patients with chronic kidney disease (CKD) (RR = 0.53, 95% CI 0.30–0.93, P = .03) or diabetes mellitus (DM) (RR = 0.51, 95% CI 0.31–0.86, P = .01) or acute coronary syndrome (ACS) patients undergoing PCI (RR = 0.52, 95% CI 0.35–0.76, P = .0009) or in studies which received mean contrast volume ≥110 mL (RR = 0.43, 95% CI 0.32–0.58, P < .0001). The SCr, CysC, hs-CRP, and mALB after the operation in the moderate or high-dose rosuvastatin group were lower than those of low-dose rosuvastatin group. Conclusion: This meta-analysis demonstrated that moderate or high-dose rosuvastatin treatment could reduce the incidence of CIN in patients undergoing CAG or PCI. Moreover, moderate or high-dose rosuvastatin would be beneficial in high-risk patients with CKD or DM or undergoing PCI. PMID:28682890
Study of pharmacological activities of methanol extract of Jatropha gossypifolia fruits
Apu, Apurba Sarker; Hossain, Faruq; Rizwan, Farhana; Bhuyan, Shakhawat Hossan; Matin, Maima; Jamaluddin, A.T.M
2012-01-01
Objective: The present study was carried out to investigate the possible in vivo analgesic, neuropharmacological and anti-diarrheal activities of the methanol extract of Jatropha gossypifolia fruits. Materials and Methods: The analgesic activity was measured by acetic acid induced writhing inhibition test. The neuropharmacological activities were evaluated by hole cross, hole-board, and elevated plus-maze (EPM) tests and the anti-diarrheal activity was assessed by castor oil induced diarrhea inhibition method. Findings: The extract showed highly significant (P < 0.001) analgesic activity with % inhibitions of writhing response at doses 200 and 400 mg/kg body weight were 77.86% and 71.25%, respectively. The extract at both doses showed significant (P < 0.05) sedative effect in-hole cross test. In-hole board test, the extract showed highly significant (P < 0.001) anxiolytic activity at lower dose whereas this activity was observed at higher dose in EPM test. The extract also showed highly significant (P < 0.001) anti-diarrheal activity. Conclusion: The findings of the study clearly indicate the presence of significant analgesic, neuropharmacological and anti-diarrheal properties of the plant, which demands further investigation including, compound isolation. PMID:24808665
Wu, Yuhsin; Schomisch, Steve J.; Cipriano, Cassandra; Chak, Amitabh; Lash, Richard H.; Ponsky, Jeffrey L.
2015-01-01
Background Esophageal endoscopic submucosal dissection (ESD) is an effective minimally invasive therapy for early esophageal cancer and high-grade Barrett dysplasia. However, esophageal stricture formation after circumferential or large ESD has limited its wide adoption. Mitomycin C (MMC), halofuginone (Hal), and transforming growth factor β3 (TGF-β3) exhibits antiscarring effects that may prevent post-ESD stricture formation. Methods Using endoscopic mucosectomy (EEM) technique, an 8- to 10-cm-long circumferential esophageal mucosal segment was excised in a porcine model. The site was either untreated (control, n = 6) or received 40 evenly distributed injections of antiscarring agent immediately and at weeks 1 and 2. High and low doses were used: MMC 5 mg (n = 2), 0.5 mg (n = 2); Hal 5 mg (n = 2), 1.5 mg (n = 2), 0.5 mg (n = 2); TGF-β3 2 μg (n = 2), 0.5 μg (n = 2). The degree of stricture formation was determined by the percentage reduction of the esophageal lumen on weekly fluoroscopic examination. Animals were euthanized when strictures exceeded 80 % or the animals were unable to maintain weight. Results The control group had a luminal diameter reduction of 78.2 ± 10.9 % by 2 weeks and were euthanized by week 3. Compared at 2 weeks, the Hal group showed a decrease in mean stricture formation (68.4 % low dose, 57.7 % high dose), while both TGF-β3 dosage groups showed no significant change (65.3 % low dose, 76.2 % high dose). MMC was most effective in stricture prevention (53.6 % low dose, 35 % high dose). Of concern, the esophageal wall treated with high-dose MMC appeared to be necrotic and eventually led to perforation. In contrast, low dose MMC, TGF-β3 and Hal treated areas appeared re-epithelialized and healthy. Conclusions Preliminary data on MMC and Hal demonstrated promise in reducing esophageal stricture formation after EEM. More animal data are needed to perform adequate statistical analysis in order to determine overall efficacy of antiscarring therapy. PMID:24100858
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kotecha, Rupesh; Djemil, Toufik; Tendulkar, Rahul D.
Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the targetmore » volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aitkenhead, A; Hamlett, L; Wood, D
2014-06-01
Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall wasmore » identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.« less
Feng, Xuan; Han, Diana; Kilaru, Bharat K.; Franek, Beverly S.; Niewold, Timothy B.; Reder, Anthony T.
2014-01-01
Objective To determine whether statins affect type 1 interferon responses in relapsing-remitting multiple sclerosis (RRMS). Design Study effects of atorvastatin on type 1 interferon responses in Jurkat cells, mononuclear cells (MNCs) from therapy-naive patients with RRMS in vitro, and MNCs from interferon-treated RRMS patients in vivo in 4 conditions: no drug, statin only, interferon-beta only, and statin added on to interferon-beta therapy. Patients The study examined clinically stable patients with RRMS: 21 therapy-naive patients and 14 patients receiving interferon-beta with a statin. Interventions Statin effects on in vitro and in vivo interferon-beta–induced STAT1 transcription factor activation, expression of interferon-stimulated proteins in MNCs, and serum type 1 interferon activity. Results In vitro, atorvastatin dose dependently inhibited expression of interferon-stimulated P-Y-STAT1 by 44% (P< .001), interferon regulatory factor 1 protein by 30% (P= .006), and myxovirus resistance 1 protein by 32% (P=.004) compared with no-statin control in MNCs from therapy-naive RRMS patients. In vivo, 9 of 10 patients who received high-dose statins (80 mg) had a significant reduction in interferon-beta therapy–induced serum interferon-α/β activity, whereas only 2 of 4 patients who received medium-dose statins (40 mg) had reductions. High-dose add-on statin therapy significantly blocked interferon-beta function, with less P-Y-STAT1 transcription factor activation, and reduced myxovirus resistance 1 protein and viperin protein production. Medium doses of statins did not change STAT1 activation. Conclusions High-dose add-on statin therapy significantly reduces interferon-beta function and type 1 interferon responses in RRMS patients. These data provide a putative mechanism for how statins could counteract the beneficial effects of interferon-beta and worsen disease. PMID:22801747
Gandhi, Ranju; Sunder, Rani
2012-01-01
Background: Analgesic efficacy of rectal acetaminophen is variable in different surgical procedures. Little data is available on its efficacy in ophthalmic surgeries. We conducted this prospective, randomized, double blind study to evaluate and compare the efficacy of single high dose and low dose rectal acetaminophen in pediatric ophthalmic surgery over a 24 hour period. Materials and Methods: 135 children scheduled for elective ophthalmic surgery were randomly allocated to one of the three groups, high, low, or control (H, L, or N) and received rectal acetaminophen 40 mg/kg, 20 mg/kg or no rectal drug respectively after induction of general anesthesia. Postoperative observations included recovery score, hourly observational pain score (OPS) up to 8 hours, time to first analgesic demand, and requirement of rescue analgesics and antiemetics over a 24 hour period. Results: Nineteen of 30 (63%) of children in group N required postoperative rescue analgesic versus 5/48 (10%) of group H (P <0.0001) and 10/47 (23%) of group L (P =0.0005) during 24 hour period. Mean time to requirement of first analgesic was 206±185 min in group H, 189±203min in group L, and 196 ±170 min in group N (P=0.985). OPS was significantly lower in group H and L compared to group N during first 8 hours. Requirement of rescue antiemetic was 18.7% in group H as compared to 23% each in group L and group N (P >0.5). Conclusions: Single dose rectal acetaminophen can provide effective postoperative analgesia for pediatric ophthalmic surgery at both high dose (40 mg/kg) and low dose (20 mg/kg) both in early postoperative and over a 24 hour period. PMID:23225924
Decongestion Strategies and Renin-Angiotensin-Aldosterone System Activation in Acute Heart Failure
Mentz, Robert J.; Stevens, Susanna R.; DeVore, Adam D.; Lala, Anuradha; Vader, Justin M.; AbouEzzeddine, Omar F.; Khazanie, Prateeti; Redfield, Margaret M.; Stevenson, Lynne W.; O'Connor, Christopher M.; Goldsmith, Steven R.; Bart, Bradley A.; Anstrom, Kevin J.; Hernandez, Adrian F.; Braunwald, Eugene; Felker, G. Michael
2014-01-01
Background High dose diuretics in patients with acute heart failure (AHF) are thought to activate the renin-angiotensin-aldosterone system (RAAS), and alternative decongestion strategies, such as ultrafiltration (UF), have been proposed to mitigate this RAAS activation. Methods We analyzed 427 AHF patients enrolled in the DOSE-AHF and CARRESS-HF trials. We assessed the relationship between two markers of RAAS activation (plasma renin activity [PRA] and aldosterone) from baseline to 72-96h and decongestion strategy; high vs. low-dose and continuous infusion vs. bolus furosemide for DOSE-AHF and UF vs. stepped pharmacologic care for CARRESS-HF. We determined the relationship between RAAS biomarkers and 60-day outcomes. Results Patients with greater RAAS activation at baseline had lower blood pressures, lower serum sodium, and higher BUN. Continuous infusion furosemide and UF were associated with greater PRA increases (median +1.66 vs. +0.66 ng/mL/h with continuous vs. bolus, P=0.021; +4.05 vs. +0.56 ng/mL/h with UF vs. stepped care, P=0.014). There was no significant difference in RAAS biomarker change with high vs. low-dose diuretics (both P>0.5). Neither baseline log PRA nor log aldosterone was associated with increased death/HF hospitalization (HR for a doubling 1.05; 95% CI: 0.98-1.13, P=0.18 and HR 1.13; 95% CI: 0.99-1.28, P=0.069, respectively). The change in RAAS biomarkers from baseline to 72-96 h was not associated with outcomes (both P>0.5). Conclusions High-dose loop diuretics did not result in greater RAAS activation than low-dose diuretics. UF resulted in greater PRA increase than stepped pharmacologic care. Neither PRA nor aldosterone was significantly associated with short-term outcomes in this cohort. PMID:25543972
Effects of Chronic Genistein Treatment in Mammary Gland, Uterus, and Vagina
Rimoldi, Guillermo; Christoffel, Julie; Seidlova-Wuttke, Dana; Jarry, Hubertus; Wuttke, Wolfgang
2007-01-01
Background The isoflavone genistein (GEN) is found in soy (Glycine max) and red clover (Trifolium pratense). The estrogenic activity of GEN is known, and it is widely advertised as a phytoestrogen useful in alleviating climacteric complaints and other postmenopausal disorders. Knowledge of effects of long-term administration of GEN in laboratory animals is scarce, and effects in the uterus and mammary gland after long-term administration have not been studied. The uterus and mammary gland are known to be negatively influenced by estrogens used in hormone therapy. Objectives We administered two doses of GEN [mean daily uptake 5.4 (low) or 54 mg/kg (high) body weight (bw)] orally over a period of 3 months to ovariectomized (ovx) rats and compared the effects with a treatment with two doses of 17β-estradiol [E2; 0.17 (low) or 0.7 mg/kg bw (high)]. Mammary glands, vaginae, and uteri were investigated morphologically and immunohistochemically. We quantified the expression of proliferating cell nuclear antigen (PCNA) and progesterone receptor (PR) in the mammary gland. Results In rats treated with either of the E2 doses or the high GEN dose, we found increased uterine weight, and histologic analysis showed estrogen-induced features in the uteri. In vaginae, either E2 dose or GEN high induced hyperplastic epithelium compared with the atrophic controls. In the mammary gland, E2 (either dose) or GEN increased proliferation and PR expression. Serum levels of luteinizing hormone were decreased by E2 (both doses) but not by GEN. Conclusions In summary, E2 and GEN share many effects in the studied organs, particularly in the vagina, uterus, and mammary gland but not in the hypothalamo/pituitary unit. PMID:18174952
Pitfalls associated with the therapeutic reference pricing practice of asthma medication
2012-01-01
Background Therapeutic reference pricing (TRP) based on the WHO daily defined dose (DDD) is a method frequently employed for the cost-containment of pharmaceuticals. Our objective was to compare average drug use in the real world with DDD and to evaluate whether TRP based on DDD could result in cost savings on maintenance medication and the total direct health expenditures for asthma patients treated with Symbicort Turbuhaler (SYT) and Seretide Diskus (SED) in Hungary. Methods Real-world data were derived from the Hungarian National Health Insurance Fund database. Average doses and costs were compared between the high-dose and medium-dose SYT and SED groups. Multiple linear regressions were employed to adjust the data for differences in the gender and age distribution of patients. Results 27,779 patients with asthma were included in the analysis. Average drug use was lower than DDD in all groups, 1.38-1.95 inhalations in both SED groups, 1.28-1.97 and 1.74-2.49 inhalations in the medium and high-dose SYT groups, respectively. Although the cost of SED based on the DDD would be much lower than the cost of SYT in the medium-dose groups, no difference was found in the actual cost of the maintenance therapy. No significant differences were found between the groups in terms of total medical costs. Conclusions Cost-containment initiatives by payers may influence clinical decisions. TRP for inhalation asthma drugs raises special concern, because of differences in the therapeutic profile of pharmaceuticals and the lack of proven financial benefits after exclusion of the effect of generic price erosion. Our findings indicate that the presented TRP approach of asthma medications based on the daily therapeutic costs according to the WHO DDD does not result in reduced public healthcare spending in Hungary. Further analysis is required to show whether TRP generates additional expenditures by inducing switching costs and reducing patient compliance. Potential confounding factors may limit the generalisability of our conclusions. PMID:22818402
An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological
Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA
2016-01-01
Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121
Effects of aqueous extract of Arctium lappa L. roots on serum lipid metabolism.
Hou, Bo; Wang, Wencheng; Gao, Hui; Cai, Shanglang; Wang, Chunbo
2018-01-01
Objective To identify potential genes that may be involved in lipid metabolism in rats after treatment with aqueous extract of Arctium lappa L (burdock). Methods Rats were randomly divided into six groups: (i) control (standard diet); (ii) model group (high-fat diet only); (iii) high-fat diet and low-dose aqueous burdock root extract (2 g/kg); (iv) high-fat diet and moderate-dose aqueous burdock root extract (4 g/kg); (v) high-fat diet and high-dose aqueous burdock root extract (8 g/kg); and (vi) a positive control group exposed to a high-fat diet and simvastatin (10 mg/kg). Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis was performed to find the potential candidate genes involved in the modulation of blood lipids by treatment with aqueous burdock root extract. Results Burdock root extract reduced body weight and cholesterol levels in rats. KEGG analysis revealed 113 genes that were involved in metabolic pathways. Of these, 27 potential genes associated with blood lipid metabolism were identified. Conclusions Aqueous extract of burdock root reduced body weight and cholesterol in rats, possibly by modulating the differential expression of genes.
Einstein, Andrew J.; Blankstein, Ron; Andrews, Howard; Fish, Mathews; Padgett, Richard; Hayes, Sean W.; Friedman, John D.; Qureshi, Mehreen; Rakotoarivelo, Harivony; Slomka, Piotr; Nakazato, Ryo; Bokhari, Sabahat; Di Carli, Marcello; Berman, Daniel S.
2015-01-01
SPECT myocardial perfusion imaging (MPI) plays a central role in coronary artery disease diagnosis; but concerns exist regarding its radiation burden. Compared to standard Anger-SPECT (A-SPECT) cameras, new high-efficiency (HE) cameras with specialized collimators and solid-state cadmium-zinc-telluride detectors offer potential to maintain image quality (IQ), while reducing administered activity and thus radiation dose to patients. No previous study has compared IQ, interpretation, total perfusion deficit (TPD), or ejection fraction (EF) in patients receiving both ultra-low-dose (ULD) imaging on a HE-SPECT camera and standard low-dose (SLD) A-SPECT imaging. Methods We compared ULD-HE-SPECT to SLD-A-SPECT imaging by dividing the rest dose in 101 patients at 3 sites scheduled to undergo clinical A-SPECT MPI using a same day rest/stress Tc-99m protocol. Patients received HE-SPECT imaging following an initial ~130 MBq (3.5mCi) dose, and SLD-A-SPECT imaging following the remainder of the planned dose. Images were scored visually by 2 blinded readers for IQ and summed rest score (SRS). TPD and EF were assessed quantitatively. Results Mean activity was 134 MBq (3.62 mCi) for ULD-HE-SPECT (effective dose 1.15 mSv) and 278 MBq (7.50 mCi, 2.39 mSv) for SLD-A-SPECT. Overall IQ was superior for ULD-HE-SPECT (p<0.0001), with twice as many studies graded excellent quality. Extracardiac activity and overall perfusion assessment were similar. Between-method correlations were high for SRS (r=0.87), TPD (r=0.91), and EF (r=0.88). Conclusion ULD-HE-SPECT rest imaging correlates highly with SLD-A-SPECT. It has improved image quality, comparable extracardiac activity, and achieves radiation dose reduction to 1 mSv for a single injection. PMID:24982439
Shinoda, Yasutaka; Kuroda, Ayaka; Yoshida, Aya; Mitsuoka, Machiko; Mori, Kouki; Kawachi, Yuki; Moriya, Akihiro; Tanaka, Kouji; Takeda, Atsuko; Yoshimura, Tomoaki; Sugiyama, Tadashi
2018-01-01
Background Daikenchuto (DKT) is a Kampo medicine used for the treatment of constipation. In this study, we evaluated the effectiveness of DKT against constipation. Patients and Methods Thirty-three patients administered DKT for constipation were selected and divided into low-dose (7.5 g DKT; n = 22) and high-dose (15 g DKT; n = 11) groups. We retrospectively evaluated weekly defaecation frequency, side effects, and clinical laboratory data. Results Median defaecation frequencies after DKT administration (5, 5.5, 5, and 8 for the first, second, third, and fourth weeks, resp.) were significantly higher than that before DKT administration (2) in all 33 cases (P < 0.01). One case (3%) of watery stool, one case of loose stools (3%), and no cases of abdominal pain (0%) were observed. Median defaecation frequencies in the high-dose group (7 and 9) were significantly higher than those in the low-dose group (4 and 3) in the first (P = 0.0133) and second (P = 0.0101) weeks, respectively. There was no significant change in clinical laboratory values. Conclusion We suggest that DKT increases defaecation frequency and is safe for treating constipation. PMID:29693001
Determining the mechanical properties of a radiochromic silicone-based 3D dosimeter
NASA Astrophysics Data System (ADS)
Kaplan, L. P.; Høye, E. M.; Balling, P.; Muren, L. P.; Petersen, J. B. B.; Poulsen, P. R.; Yates, E. S.; Skyt, P. S.
2017-07-01
New treatment modalities in radiotherapy (RT) enable delivery of highly conformal dose distributions in patients. This creates a need for precise dose verification in three dimensions (3D). A radiochromic silicone-based 3D dosimetry system has recently been developed. Such a dosimeter can be used for dose verification in deformed geometries, which requires knowledge of the dosimeter’s mechanical properties. In this study we have characterized the dosimeter’s elastic behaviour under tensile and compressive stress. In addition, the dose response under strain was determined. It was found that the dosimeter behaved as an incompressible hyperelastic material with a non-linear stress/strain curve and with no observable hysteresis or plastic deformation even at high strains. The volume was found to be constant within a 2% margin at deformations up to 60%. Furthermore, it was observed that the dosimeter returned to its original geometry within a 2% margin when irradiated under stress, and that the change in optical density per centimeter was constant regardless of the strain during irradiation. In conclusion, we have shown that this radiochromic silicone-based dosimeter’s mechanical properties make it a viable candidate for dose verification in deformable 3D geometries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heintz, P; Heintz, B; Sandoval, D
Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. Themore » subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zerouali, K; Aubry, J; Doucet, R
2016-06-15
Purpose: To implement the new EBT-XD Gafchromic films for accurate dosimetric and geometric validation of stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) CyberKnife (CK) patient specific QA. Methods: Film calibration was performed using a triplechannel film analysis on an Epson 10000XL scanner. Calibration films were irradiated using a Varian Clinac 21EX flattened beam (0 to 20 Gy), to ensure sufficient dose homogeneity. Films were scanned to a resolution of 0.3 mm, 24 hours post irradiation following a well-defined protocol. A set of 12 QA was performed for several types of CK plans: trigeminal neuralgia, brain metastasis, prostate andmore » lung tumors. A custom made insert for the CK head phantom has been manufactured to yield an accurate measured to calculated dose registration. When the high dose region was large enough, absolute dose was also measured with an ionization chamber. Dose calculation is performed using MultiPlan Ray-tracing algorithm for all cases since the phantom is mostly made from near water-equivalent plastic. Results: Good agreement (<2%) was found between the dose to the chamber and the film, when a chamber measurement was possible The average dose difference and standard deviations between film measurements and TPS calculations were respectively 1.75% and 3%. The geometric accuracy has been estimated to be <1 mm, combining robot positioning uncertainty and film registration to calculated dose. Conclusion: Patient specific QA measurements using EBT-XD films yielded a full 2D dose plane with high spatial resolution and acceptable dose accuracy. This method is particularly promising for trigeminal neuralgia plan QA, where the positioning of the spatial dose distribution is equally or more important than the absolute delivered dose to achieve clinical goals.« less
Yan, Ling; Ye, Lu; Wang, Kun; Zhou, Jie; Zhu, Chunjia
2016-05-25
Objective: To investigate the effect of atorvastatin on reflow in patients with acute ST-segment elevation myocardial infarction (STEMI) after percutaneous coronary intervention (PCI) and its relation to serum uric acid levels. Methods: One hundred and fourteen STEMI patients undergoing primary PCI were enrolled and randomly divided into two groups:55 cases received oral atorvastatin 20 mg before PCI (routine dose group) and 59 cases received oral atorvastatin 80 mg before PCI (high dose group). According to the initial serum uric acid level, patients in two groups were further divided into normal uric acid subgroup and hyperuricemia subgroup. The changes of uric acid level and coronary artery blood flow after PCI were observed. Correlations between the decrease of uric acid, the dose of atorvastatin and the blood flow of coronary artery after PCI were analyzed. Results: Serum uric acid levels were decreased after treatment in both groups (all P <0.05), and patients with hyperuricemia showed more significant decrease in serum uric acid level ( P <0.05). Compared with the routine dose group, serum uric acid level in patients with hyperuricemia decreased more significantly in the high dose group ( P <0.05), but no significant difference was observed between patients with normal serum uric acid levels in two groups ( P >0.05). Among 114 patients, there were 19 cases without reflow after PCI (16.7%). In the routine dose group, there were 12 patients without reflow, in which 3 had normal uric acid and 9 had high uric acid levels ( P <0.01). In the high dose group, there were 7 patients without reflow, in which 2 had normal uric acid and 5 had high uric acid ( P <0.05). Logistic regression analysis showed that hyperuricemia was one of independent risk factors for no-reflow after PCI ( OR =1.01, 95% CI :1.01-1.11, P <0.01). The incidence of no-flow after PCI in the routine dose group was 21.8% (12/55), and that in the high dose group was 11.9% (7/59) ( P <0.01). Conclusion: High dose atorvastatin can decrease serum uric acid levels and improve reflow after PCI in patients with STEMI.
Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B.
2016-01-01
Objectives IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Methods Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75–95, 36.25–145, 48.75–195, and 61.25–245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Results Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. Conclusions IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption. PMID:26626430
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, John M.; Lockman, David; Yan Di
Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volumemore » parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.« less
[Influence of n-hexane on vascular endothelial active substances in brain tissue in mice].
Lin, L; Zhang, Z Q; Zhang, C Z
2017-01-20
Objective: To investigate the influence of n - hexane on vascular endothelial active substances in brain tissue in mice and its significance. Methods: A total of 48 healthy Kunming mice were randomly divided into high - dose exposure group, middle - dose exposure group, low - dose exposure group, and control group, with 12 mice in each group. All groups except the control group were exposed to n - hexane via static inhalation (0.035 g/L, 0.018 g/L, and 0.009 g/L for the high - , middle - , and low - dose exposure groups, respectively) 4 hours a day for 21 days. the mice in the control groups were not exposed to n - hexane. After the exposure, the lev-els of endothelin - 1 (ET - 1) , nitric oxide (NO) , and angiotensin II (Ang II) in brain tissue were measured in all groups. Results: There were significant differences in the levels of ET - 1, NO, and Ang II between the three ex-posure groups and the control group ( P <0.05). Compared with the control group, the high - and middle - dose expo-sure group had significant increases in the levels of ET - 1 and Ang II and the high - dose exposure group had a sig-nificant reduction in the level of NO ( P <0.05 or P <0.01). Conclusion: n - Hexane can affect the vascular endothe-lial active substances in brain tissue in mice, and the changes and imbalance in vascular endothelial active sub-stances may be one of the reasons for central nervous system impairment caused by n - hexane.
Survival After Shock Requiring High-Dose Vasopressor Therapy
Lanspa, Michael J.; Jones, Jason P.; Kuttler, Kathryn G.; Li, Yao; Carlson, Rick; Miller, Russell R.; Hirshberg, Eliotte L.; Grissom, Colin K.; Morris, Alan H.
2013-01-01
Background: Some patients with hypotensive shock do not respond to usual doses of vasopressor therapy. Very little is known about outcomes after high-dose vasopressor therapy (HDV). We sought to characterize survival among patients with shock requiring HDV. We also evaluated the possible utility of stress-dose corticosteroid therapy in these patients. Methods: We conducted a retrospective study of patients with shock requiring HDV in the ICUs of five hospitals from 2005 through 2010. We defined HDV as receipt at any point of ≥ 1 μg/kg/min of norepinephrine equivalent (calculated by summing norepinephrine-equivalent infusion rates of all vasopressors). We report survival 90 days after hospital admission. We evaluated receipt of stress-dose corticosteroids, cause of shock, receipt of CPR, and withdrawal or withholding of life support therapy. Results: We identified 443 patients meeting inclusion criteria. Seventy-six (17%) survived. Survival was similar (20%) among the 241 patients with septic shock. Among the 367 nonsurvivors, 254 (69%) experienced withholding/withdrawal of care, and 115 (31%) underwent CPR. Stress-dose corticosteroid therapy was associated with increased survival (P = .01). Conclusions: One in six patients with shock survived to 90 days after HDV. The majority of nonsurvivors died after withdrawal or withholding of life support therapy. A minority of patients underwent CPR. Additionally, stress-dose corticosteroid therapy appears reasonable in patients with shock requiring HDV. PMID:22911566
SU-F-T-441: Dose Calculation Accuracy in CT Images Reconstructed with Artifact Reduction Algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, C; Chan, S; Lee, F
Purpose: Accuracy of radiotherapy dose calculation in patients with surgical implants is complicated by two factors. First is the accuracy of CT number, second is the dose calculation accuracy. We compared measured dose with dose calculated on CT images reconstructed with FBP and an artifact reduction algorithm (OMAR, Philips) for a phantom with high density inserts. Dose calculation were done with Varian AAA and AcurosXB. Methods: A phantom was constructed with solid water in which 2 titanium or stainless steel rods could be inserted. The phantom was scanned with the Philips Brillance Big Bore CT. Image reconstruction was done withmore » FBP and OMAR. Two 6 MV single field photon plans were constructed for each phantom. Radiochromic films were placed at different locations to measure the dose deposited. One plan has normal incidence on the titanium/steel rods. In the second plan, the beam is at almost glancing incidence on the metal rods. Measurements were then compared with dose calculated with AAA and AcurosXB. Results: The use of OMAR images slightly improved the dose calculation accuracy. The agreement between measured and calculated dose was best with AXB and image reconstructed with OMAR. Dose calculated on titanium phantom has better agreement with measurement. Large discrepancies were seen at points directly above and below the high density inserts. Both AAA and AXB underestimated the dose directly above the metal surface, while overestimated the dose below the metal surface. Doses measured downstream of metal were all within 3% of calculated values. Conclusion: When doing treatment planning for patients with metal implants, care must be taken to acquire correct CT images to improve dose calculation accuracy. Moreover, great discrepancies in measured and calculated dose were observed at metal/tissue interface. Care must be taken in estimating the dose in critical structures that come into contact with metals.« less
SU-E-T-238: Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chibani, O; Price, R; Ma, C
Purpose: Estimation of Cerenkov dose from high-energy megavoltage photon and electron beams in tissue and its impact on the radiosensitization using Protoporphyrine IX (PpIX) for tumor targeting enhancement in radiotherapy. Methods: The GEPTS Monte Carlo code is used to generate dose distributions from 18MV Varian photon beam and generic high-energy (45-MV) photon and (45-MeV) electron beams in a voxel-based tissueequivalent phantom. In addition to calculating the ionization dose, the code scores Cerenkov energy released in the wavelength range 375–425 nm corresponding to the pick of the PpIX absorption spectrum (Fig. 1) using the Frank-Tamm formula. Results: The simulations shows thatmore » the produced Cerenkov dose suitable for activating PpIX is 4000 to 5500 times lower than the overall radiation dose for all considered beams (18MV, 45 MV and 45 MeV). These results were contradictory to the recent experimental studies by Axelsson et al. (Med. Phys. 38 (2011) p 4127), where Cerenkov dose was reported to be only two orders of magnitude lower than the radiation dose. Note that our simulation results can be corroborated by a simple model where the Frank and Tamm formula is applied for electrons with 2 MeV/cm stopping power generating Cerenkov photons in the 375–425 nm range and assuming these photons have less than 1mm penetration in tissue. Conclusion: The Cerenkov dose generated by high-energy photon and electron beams may produce minimal clinical effect in comparison with the photon fluence (or dose) commonly used for photo-dynamic therapy. At the present time, it is unclear whether Cerenkov radiation is a significant contributor to the recently observed tumor regression for patients receiving radiotherapy and PpIX versus patients receiving radiotherapy only. The ongoing study will include animal experimentation and investigation of dose rate effects on PpIX response.« less
Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meijer, Hanneke J.M., E-mail: H.Meijer@rther.umcn.nl; Debats, Oscar A.; Kunze-Busch, Martina
2012-01-01
Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineatedmore » on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.« less
Heins, Sara E; Sorbero, Mark J; Jones, Christopher M; Dick, Andrew W; Stein, Bradley D
2018-01-05
Prescription opioid overdoses have increased dramatically in recent years, with the highest rates among Medicaid enrollees. High-risk prescribing includes practices associated with overdoses and a range of additional opioid-related problems. To identify individual- and county-level factors associated with high-risk prescribing among Medicaid enrollees receiving opioids. In a four-states, cross-sectional claims data study, Medicaid enrollees 18-64 years old with a new opioid analgesic treatment episode 2007-2009 were identified. Multivariate regression analyses were conducted to identify factors associated with high-risk prescribing, defined as high-dose opioid prescribing (morphine equivalent daily dose ≥100 mg for >6 days), opioid overlap, opioid-benzodiazepine overlap. High-risk prescribing occurred in 39.4% of episodes. Older age, rural county of residence, white race, and major depression diagnosis were associated with higher rates of all types of high-risk prescribing. Individuals with prior opioid, alcohol, and hypnotic/sedative use disorder diagnoses had lower odds of high-dose opioid prescribing but higher odds of opioid overlap and opioid-benzodiazepine overlap than individuals without such disorders. High-dose opioid prescribing in Massachusetts was less common than in California, Illinois, and New York, whereas the rate of benzodiazepine overlap in Massachusetts was more common than in other states. Conclusions/Importance: High-risk prescribing was common and associated with several important demographic, clinical, and community factors. Findings can be used to inform targeted interventions designed to reduce such prescribing, and given state variation observed, further research is needed to better understand the effects of state policies on high-risk prescribing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hermansen, M; Bova, F; John, T St.
2015-06-15
Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-processmore » dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.« less
Radiation-related thyroid autoimmunity and dysfunction
Nagayama, Yuji
2018-01-01
Abstract The thyroid gland is vulnerable not only to external radiation but also to internal radiation, because the thyroid cells can incorporate radioactive iodine when synthesizing thyroid hormones. Since radiation-induction of thyroid neoplasia, including thyroid cancer, is well recognized, the data on radiation-related thyroid autoimmunity and dysfunction are summarized and reviewed. High-dose irradiation, irrespective of being external or internal, is strongly associated with a risk of hypothyroidism (with the prevalence ranging from 2.4% to 31%) and of Graves’ hyperthyroidism (with the prevalence being up to 5%). It is easy to understand that high-dose irradiation induces hypothyroidism with some frequency, because high-dose irradiation destroys the thyroid gland. On the other hand, the basis for development of hyperthyroidism is mechanistically unclear, and it is merely speculative that autoantigens may be released from damaged thyroid glands and recognized by the immune system, leading to the development of anti-thyrotropin receptor antibodies and Graves’ hyperthyroidism in subjects who are immunologically predisposed to this ailment. In contrast, the data on moderate to low-dose irradiation on thyroid autoimmunity and dysfunction are inconsistent. Although it is difficult to draw a definitive conclusion, some data may suggest a transient effect of moderate- to low-dose irradiation on hypothyroidism and autoimmune thyroiditis, implying that the effect, if it exists, is reversible. Finally, no report has shown a statistically significant increase in the prevalence of moderate- to low-dose irradiation–induced Graves’ hyperthyroidism. PMID:29069397
High doses of dextromethorphan, an NMDA antagonist, produce effects similar to classic hallucinogens
Carter, Lawrence P.; Johnson, Matthew W.; Mintzer, Miriam Z.; Klinedinst, Margaret A.; Griffiths, Roland R.
2013-01-01
Rationale Although reports of dextromethorphan (DXM) abuse have increased recently, few studies have examined the effects of high doses of DXM. Objective This study in humans evaluated the effects of supratherapeutic doses of DXM and triazolam. Methods Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg/70kg), and placebo were administered to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Subjective, behavioral, and physiological effects were assessed repeatedly after drug administration for 6 hours. Results Triazolam produced dose-related increases in subject-rated sedation, observer-rated sedation, and behavioral impairment. DXM produced a profile of dose-related physiological and subjective effects differing from triazolam. DXM effects included increases in blood pressure, heart rate, and emesis, increases in observer-rated effects typical of classic hallucinogens (e.g. distance from reality, visual effects with eyes open and closed, joy, anxiety), and participant ratings of stimulation (e.g. jittery, nervous), somatic effects (e.g. tingling, headache), perceptual changes, end-of-session drug liking, and mystical-type experience. After 400 mg/70kg DXM, 11 of 12 participants indicated on a pharmacological class questionnaire that they thought they had received a classic hallucinogen (e.g. psilocybin). Drug effects resolved without significant adverse effects by the end of the session. In a 1-month follow up volunteers attributed increased spirituality and positive changes in attitudes, moods, and behavior to the session experiences. Conclusions High doses of DXM produced effects distinct from triazolam and had characteristics that were similar to the classic hallucinogen psilocybin. PMID:22526529
Abdel Aziz, Rabie L; Abdel-Wahab, Ahmed; Abo El-Ela, Fatma I; Hassan, Nour El-Houda Y; El-Nahass, El-Shaymaa; Ibrahim, Marwa A; Khalil, Abdel-Tawab A Y
2018-06-01
This study aimed to determine the protective effects of co-administration of Quercetin (QT) or l-Carnitine (LC) against the oxidative stress induced by Atrazine (ATZ) in the reproductive system of intact male Albino rats. 36 rats were divided equally into 6 groups. Rats in the control negative "CNT" group received 1.5 ml distilled water for 21 days. All rats in the other groups received ATZ (120 mg/kg bw) through gavage. Groups 3 and 4 were co-administered with either low or high dose of QT (10 "ATZLQT" and 50 "ATZHQT" mg/kg bw, respectively). Groups 5 and 6 were co-administered with either low or high dose of LC (200 "ATZLLC" and 400 "ATZHLC" mg/kg bw, respectively). At the end of the experiment, animals were sacrificed and all samples were collected. ATZ significantly increased serum level of malondialdehyde (MDA) and decreased total antioxidant capacity (TAC). Also, ATZ increased significantly the sperm cell abnormalities and reduced both testicular IgA and serum testosterone levels. Testicular DNA laddering % and CYP17A1 mRNA expression were significantly reduced in ATZ group. Interestingly, co-administration with low dose QT or different doses of LC succeeded to counteract the negative toxic effects of ATZ on serum oxidative stress indicators, serum testosterone levels, testicular IgA level and improved testicular CYP17A1 mRNA expression. In conclusion, QT in low dose and LC in both low and high doses exerted a significant protective action against the reproductive toxicity of ATZ, while higher dose of QT failed induce immune-stimulant effect against ATZ in adult male Albino rats. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Qayyum, Rehan; Becker, Diane M.; Yanek, Lisa R.; Moy, Taryn F.; Becker, Lewis C.; Faraday, Nauder; Vaidya, Dhananjay
2011-01-01
Compared to men, women have greater platelet aggregation before and after low-dose aspirin. It is not known whether high-dose aspirin therapy brings residual platelet aggregation in women closer to men. Our objective was to compare the inhibition of platelet aggregation in women and men after low and high-dose aspirin. We enrolled healthy subjects (N=106) in a trial of 14 days of aspirin 81 mg/day followed by 14 days of 325 mg/day. Platelet function was measured at baseline and following both aspirin doses. Women had greater baseline platelet activation measures. After both aspirin doses, both sexes had near complete suppression of platelet aggregation to arachidonic acid in whole blood and in platelet-rich plasma (PRP), the direct cyclooxygenase-1 (COX-1) pathway affected by aspirin. For indirect pathways, women had significantly greater residual platelet activation to collagen and adenosine diphosphate (ADP) in whole blood after both aspirin doses and in response to collagen and ADP in PRP after aspirin 325 mg/day only. After aspirin 325 mg/day, women continued to have greater residual platelet aggregation compared to men after aspirin 81 mg/day in response to collagen (p=0.016 in whole blood and p=0.037 in PRP), ADP (p<0.001 in whole blood and p=0.012 in PRP), and epinephrine (p=0.03 in PRP). Excretion of urinary thromboxane metabolite (urinary 11-dehydro thromboxane B2) decreased after aspirin to a similar extent in both sexes. In conclusion, women continue to have greater residual platelet activity after high-dose aspirin even when compared to men treated with a lower dose of aspirin. PMID:18435972
Behavioral effects of ketamine and toxic interactions with psychostimulants
Hayase, Tamaki; Yamamoto, Yoshiko; Yamamoto, Keiichi
2006-01-01
Background The anesthetic drug ketamine (KT) has been reported to be an abused drug and fatal cases have been observed in polydrug users. In the present study, considering the possibility of KT-enhanced toxic effects of other drugs, and KT-induced promotion of an overdose without making the subject aware of the danger due to the attenuation of several painful subjective symptoms, the intraperitoneal (i.p.) KT-induced alterations in behaviors and toxic interactions with popular co-abused drugs, the psychostimulants cocaine (COC) and methamphetamine (MA), were examined in ICR mice. Results A single dose of KT caused hyperlocomotion in a low (30 mg/kg, i.p.) dose group, and hypolocomotion followed by hyperlocomotion in a high (100 mg/kg, i.p.) dose group. However, no behavioral alterations derived from enhanced stress-related depression or anxiety were observed in the forced swimming or the elevated plus-maze test. A single non-fatal dose of COC (30 mg/kg, i.p.) or MA (4 mg/kg, i.p.) caused hyperlocomotion, stress-related depression in swimming behaviors in the forced swimming test, and anxiety-related behavioral changes (preference for closed arms) in the elevated plus-maze test. For the COC (30 mg/kg) or MA (4 mg/kg) groups of mice simultaneously co-treated with KT, the psychostimulant-induced hyperlocomotion was suppressed by the high dose KT, and the psychostimulant-induced behavioral alterations in the above tests were reversed by both low and high doses of KT. For the toxic dose COC (70 mg/kg, i.p.)- or MA (15 mg/kg, i.p.)-only group, mortality and severe seizures were observed in some animals. In the toxic dose psychostimulant-KT groups, KT attenuated the severity of seizures dose-dependently. Nevertheless, the mortality rate was significantly increased by co-treatment with the high dose KT. Conclusion Our results demonstrated that, in spite of the absence of stress-related depressive and anxiety-related behavioral alterations following a single dose of KT treatment, and in spite of the KT-induced anticonvulsant effects and attenuation of stress- and anxiety-related behaviors caused by COC or MA, the lethal effects of these psychostimulants were increased by KT. PMID:16542420
Dosimetric evaluation of internal shielding in a high dose rate skin applicator
Granero, Domingo; Perez-Calatayud, Jose; Carmona, Vicente; Pujades, M Carmen; Ballester, Facundo
2011-01-01
Purpose The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. Material and methods Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in which 2 mm lead slab was located at 3 mm depth; b) radiochromic EBT films, used to verify the Monte Carlo results, positioning the films at 1.5, 3, 5 and 7 mm depth, inside the phantom. Two irradiations, with and without the lead shielding slab, were carried out. Results The Monte Carlo results showed that due to the backscatter component from the lead, the dose level raised to about 200% with a depth range of 0.5 mm. Under the lead the dose level was enhanced to about 130% with a depth range of 1 mm. Two millimeters of lead reduce the dose under the slab with about 60%. These results agree with film measurements within uncertainties. Conclusions In conclusion, the use of 2 mm internal lead shielding in eyelid skin treatments with the Valencia applicators were evaluated using MC methods and EBT film dosimetry. The minimum bolus thickness that was needed above and below the shielding was 0.5 mm and 1 mm respectively, and the shielding reduced the absorbed dose delivered to the ocular globe by about 60%. PMID:27877198
Low-Dose, Ionizing Radiation and Age-Related Changes in Skeletal Microarchitecture
Alwood, Joshua S.; Kumar, Akhilesh; Tran, Luan H.; ...
2012-01-01
Osteoporosis can profoundly affect the aged as a consequence of progressive bone loss; high-dose ionizing radiation can cause similar changes, although less is known about lower doses (≤100 cGy). We hypothesized that exposure to relatively low doses of gamma radiation accelerates structural changes characteristic of skeletal aging. Mice (C57BL/6J-10 wk old, male) were irradiated (total body; 0-sham, 1, 10 or 100 cGy 137 Cs) and tissues harvested on the day of irradiation, 1 or 4 months later. Microcomputed tomography was used to quantify microarchitecture of high turnover, cancellous bone. Irradiation at 100 cGy caused transient microarchitectural changes over one month that were only evident atmore » longer times in controls (4 months). Ex vivo bone cell differentiation from the marrow was unaffected by gamma radiation. In conclusion, acute ionizing gamma irradiation at 100 cGy (but not at 1 cGy or 10 cGy) exacerbated microarchitectural changes normally found during progressive, postpubertal aging prior to the onset of age-related osteoporosis.« less
Low-Dose, Ionizing Radiation and Age-Related Changes in Skeletal Microarchitecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alwood, Joshua S.; Kumar, Akhilesh; Tran, Luan H.
Osteoporosis can profoundly affect the aged as a consequence of progressive bone loss; high-dose ionizing radiation can cause similar changes, although less is known about lower doses (≤100 cGy). We hypothesized that exposure to relatively low doses of gamma radiation accelerates structural changes characteristic of skeletal aging. Mice (C57BL/6J-10 wk old, male) were irradiated (total body; 0-sham, 1, 10 or 100 cGy 137 Cs) and tissues harvested on the day of irradiation, 1 or 4 months later. Microcomputed tomography was used to quantify microarchitecture of high turnover, cancellous bone. Irradiation at 100 cGy caused transient microarchitectural changes over one month that were only evident atmore » longer times in controls (4 months). Ex vivo bone cell differentiation from the marrow was unaffected by gamma radiation. In conclusion, acute ionizing gamma irradiation at 100 cGy (but not at 1 cGy or 10 cGy) exacerbated microarchitectural changes normally found during progressive, postpubertal aging prior to the onset of age-related osteoporosis.« less
Adaptive Dose Painting by Numbers for Head-and-Neck Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duprez, Frederic, E-mail: frederic.duprez@ugent.be; De Neve, Wilfried; De Gersem, Werner
Purpose: To investigate the feasibility of adaptive intensity-modulated radiation therapy (IMRT) using dose painting by numbers (DPBN) for head-and-neck cancer. Methods and Materials: Each patient's treatment used three separate treatment plans: fractions 1-10 used a DPBN ([{sup 18}-F]fluoro-2-deoxy-D-glucose positron emission tomography [{sup 18}F-FDG-PET]) voxel intensity-based IMRT plan based on a pretreatment {sup 18}F-FDG-PET/computed tomography (CT) scan; fractions 11-20 used a DPBN plan based on a {sup 18}F-FDG-PET/CT scan acquired after the eighth fraction; and fractions 21-32 used a conventional (uniform dose) IMRT plan. In a Phase I trial, two dose prescription levels were tested: a median dose of 80.9 Gymore » to the high-dose clinical target volume (CTV{sub highdose}) (dose level I) and a median dose of 85.9 Gy to the gross tumor volume (GTV) (dose level II). Between February 2007 and August 2009, 7 patients at dose level I and 14 patients at dose level II were enrolled. Results: All patients finished treatment without a break, and no Grade 4 acute toxicity was observed. Treatment adaptation (i.e., plans based on the second {sup 18}F-FDG-PET/CT scan) reduced the volumes for the GTV (41%, p = 0.01), CTV{sub highdose} (18%, p = 0.01), high-dose planning target volume (14%, p = 0.02), and parotids (9-12%, p < 0.05). Because the GTV was much smaller than the CTV{sub highdose} and target adaptation, further dose escalation at dose level II resulted in less severe toxicity than that observed at dose level I. Conclusion: To our knowledge, this represents the first clinical study that combines adaptive treatments with dose painting by numbers. Treatment as described above is feasible.« less
Peng, Yong; Shao, Hui; Ke, Yan; Zhang, Ping; Han, Gencheng; Kaplan, Henry J.; Sun, Deming
2008-01-01
Purpose Results in previous reports have demonstrated that immunization of the EAU-prone B6 mouse activates both CD4 and CD8 IRBP-specific T cells. The purpose of this study was to investigate structural and functional differences between CD4 and CD8 autoreactive T cells activated by the uveitogenic peptide. Methods Purified CD4 and CD8 isolated from B6 mice immunized with an uveitogenic peptide, interphotoreceptor retin-oid-binding protein (IRBP)1-20, were stimulated in vitro with various doses of immunizing peptide. The activated T cells were determined for cytokine production, expression of Foxp3, and suppressor activity. Results CD4 autoreactive T cells underwent full activation when stimulated with high or medium concentrations of immunizing peptide, whereas a high dose of antigenic peptide resulted in only modest activation of CD8 autoreactive T cells. When stimulated by a low dose (<0.1 μg/mL) of antigen or by of a high dose of antigen and a small amount of TGF-β1, the minimally activated CD8 T cells expressed a high level of Foxp3 and gained suppressor function. Conclusions Minimally activated CD8 autoreactive T cells can be functionally suppressive and may neutralize the tissue-damaging effect of the CD4 autoreactive T cells. PMID:17460277
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vijayan, S; Rana, V; Setlur Nagesh, S
2014-06-15
Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. Themore » DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.« less
Yang, Qian; Wu, Wei; Li, Qian; Chen, Chan; Zhou, Ronghua; Qiu, Yanhua; Luo, Ming; Tan, Zhaoxia; Li, Shen; Chen, Gang; Zhou, Wentao; Liu, Jiaxin; Yang, Chengmin; Liu, Jin; Li, Tao
2015-01-01
Objective. Ischemia/reperfusion (I/R) injury is an unavoidable event for patients in cardiac surgery under cardiopulmonary bypass (CPB). This study was designed to investigate whether glutaraldehyde-polymerized human placenta hemoglobin (PolyPHb), a hemoglobin-based oxygen carrier (HBOC), can protect heart against CPB-induced I/R injury or not and to elucidate the underlying mechanism. Methods and Results. A standard dog CPB model with 2-hour cardiac arrest and 2-hour reperfusion was established. The results demonstrated that a low-dose PolyPHb (0.1%, w/v) provided a significant protection on the I/R heart, whereas the high-dose PolyPHb (3%, w/v) did not exhibit cardioprotective effect, as evidenced by the impaired cardiac function, decreased myocardial oxygen utilization, and elevated enzymes release and pathological changes. Further study indicated that exposure of isolated coronary arteries or human umbilical vein endothelial cells (HUVECs) to a high-dose PolyPHb caused impaired endothelium-dependent relaxation, which was companied with increased reactive oxygen species (ROS) production, reduced superoxide dismutase (SOD) activity, and elevated malonaldehyde (MDA) formation. Consistent with the increased oxidative stress, the NAD(P)H oxidase activity and subunits expression, including gp91(phox), p47(phox), p67(phox), and Nox1, were greatly upregulated. Conclusion. The high-dose PolyPHb fails to protect heart from CPB-induced I/R injury, which was due to overproduction of NAD(P)H oxidase-induced ROS and resultant endothelial dysfunction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waksman, Ron; Pakala, Rajbabu; Burnett, Mary S.
Introduction: Inflammatory and immunological responses of vascular cells are known to play significant roles in atherosclerotic plaque development. Rapamycin with antiinflammatory, immunosuppressive and antiproliferative properties has been shown to reduce neointima formation when coated on stents. This study is designed to test the potential of oral rapamycin to inhibit atherosclerotic plaque development. Methods: Eight-week-old apoE knock-out mice were fed with 0.25% cholesterol supplemented diet (control diet), control diet containing 50 {mu}g/kg rapamycin (low-dose rapamycin) or 100 {mu}g/kg rapamycin (high-dose rapamycin) for 4 or 8 weeks. Subsets of mice from each group (n=10) were weighed and euthanized. Whole blood rapamycin levelsmore » were determined using HPLC-MS/MS, and histological analyses of atherosclerotic lesions in the aortic root were performed. Results: Mice fed with high-dose rapamycin did not gain weight (18.5{+-}1.5 vs. 20.6{+-}0.9 g, P=.01). Blood levels of rapamycin 117{+-}7 pg/ml were detected in the blood of mice fed with high-dose rapamycin for 8 weeks. The plaque area in mice fed with high dose oral rapamycin is significantly less as compared to control (0.168{+-}0.008 vs. 0.326{+-}0.013 mm{sup 2}, P=.001 at 4 weeks; 0.234{+-}0.013 vs. 0.447{+-}0.011 mm{sup 2}, P=.001 at 8 weeks). Lumen area was inversely proportional to the plaque area. Conclusions: The results indicate that oral rapamycin is effective in attenuating the progression of atherosclerotic plaque in the mice.« less
Yuceler, Zeyneb; Kantarci, Mecit; Yuce, Ihsan; Kizrak, Yesim; Bayraktutan, Ummugulsum; Ogul, Hayri; Kiris, Adem; Celik, Omer; Pirimoglu, Berhan; Genc, Berhan; Gundogdu, Fuat
2014-01-01
Our aim was to evaluate the diagnostic accuracy of 256-slice, high-pitch mode multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Eighty-eight patients underwent 256-slice MDCT angiography to evaluate their graft patency after CABG surgery using a prospectively synchronized electrocardiogram in the high-pitch spiral acquisition mode. Effective radiation doses were calculated. We investigated the diagnostic accuracy of high-pitch, low-dose, prospective, electrocardiogram-triggering, dual-source MDCT for CABG patency compared with catheter coronary angiography imaging findings. A total of 215 grafts and 645 vessel segments were analyzed. All graft segments had diagnostic image quality. The proximal and middle graft segments had significantly (P < 0.05) better mean image quality scores (1.18 ± 0.4) than the distal segments (1.31 ± 0.5). Using catheter coronary angiography as the reference standard, high-pitch MDCT had the following sensitivity, specificity, positive predictive value, and negative predictive value of per-segment analysis for detecting graft patency: 97.1%, 99.6%, 94.4%, and 99.8%, respectively. In conclusion, MDCT can be used noninvasively with a lower radiation dose for the assessment of restenosis in CABG patients.
The New Radiobiology: Returning to Our Roots
Ulsh, Brant A.
2012-01-01
In 2005, two expert advisory bodies examined the evidence on the effects of low doses of ionizing radiation. The U.S. National Research Council concluded that current scientific evidence is consistent with the linear no-threshold dose-response relationship (NRCNA 2005) while the French National Academies of Science and Medicine concluded the opposite (Aurengo et al. 2005). These contradictory conclusions may stem in part from an emphasis on epidemiological data (a “top down” approach) versus an emphasis on biological mechanisms (a “bottom up” approach). In this paper, the strengths and limitations of the top down and bottom up approaches are discussed, and proposals for strengthening and reconciling them are suggested. The past seven years since these two reports were published have yielded increasing evidence of nonlinear responses of biological systems to low radiation doses delivered at low dose-rates. This growing body of evidence is casting ever more doubt on the extrapolation of risks observed at high doses and dose-rates to estimate risks associated with typical environmental and occupational exposures. This paper compares current evidence on low dose, low dose-rate effects against objective criteria of causation. Finally, some questions for a post-LNT world are posed. PMID:23304107
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Hua; Department of Radiation Oncology, Cancer Hospital of Jiangxi Province, Jiangxi Province; Li Yexiong, E-mail: yexiong@yahoo.com
Purpose: The value of intensity-modulated radiotherapy (IMRT) for early-stage nasal NK/T-cell lymphoma has not been previously reported. The aim of the present study was to assess the dosimetric parameters, toxicity, and treatment outcomes of patients with nasal NK/T-cell lymphoma. Methods and Materials: Between 2003 and 2008, 42 patients with early-stage nasal NK/T-cell lymphoma underwent definitive high-dose and extended involved-field IMRT with or without combination chemotherapy. The median radiation dose to the primary tumor was 50 Gy. The dose-volume histograms of the target volume and critical normal structures were evaluated in all patients. The locoregional control, overall survival, and progression-free survivalmore » were calculated using the Kaplan-Meier method. Results: The average mean dose delivered to the planning target volume was 55.5 Gy. Only 1.3% and 2.5% of the planning target volume received <90% and 95% of the prescribed dose, respectively, indicating excellent planning target volume coverage. The mean dose and average dose to the parotid glands was 15 Gy and 14 Gy, respectively. With a median follow-up time of 27 months, the 2-year locoregional control, overall survival, and progression-free survivalrate was 93%, 78%, and 74%, respectively. No Grade 4 or 5 acute or late toxicity was reported. Conclusions: High-dose and extended involved-field IMRT for patients with early-stage nasal NK/T-cell lymphoma showed favorable locoregional control, overall survival, and progression-free survival, with mild toxicity. The dose constraints of IMRT for the parotid glands can be limited to <20 Gy in these patients.« less
Raczniak, Gregory A.; Thomas, Timothy K.; Bulkow, Lisa R.; Negus, Susan E.; Zanis, Carolyn L.; Bruce, Michael G.; Spradling, Philip R.; Teshale, Eyasu H.; McMahon, Brian J.
2015-01-01
Background Hepatitis A is mostly a self-limiting disease but causes substantial economic burden. Consequently, United States Advisory Committee for Immunization Practices recommends inactivated hepatitis A vaccination for all children beginning at age 1 year and for high risk adults. The hepatitis A vaccine is highly effective but the duration of protection is unknown. Methods We examined the proportion of children with protective hepatitis A antibody levels (anti-HAV ≥20 mIU/mL) as well as the geometric mean concentration (GMC) of anti-HAV in a cross sectional convenience sample of individuals aged 12–24 years, who had been vaccinated with a two-dose schedule in childhood, with the initial dose at least 5 years ago. We compared a subset of data from persons vaccinated with two-doses (720 EL.U.) at age 3–6 years with a demographically similar prospective cohort that received a three-dose (360 EL.U.) schedule and have been followed for 17 years. Results No significant differences were observed when comparing GMC between the two cohorts at 10 (P = 0.467), 12 (P = 0.496), and 14 (P = 0.175) years post-immunization. For the three-dose cohort, protective antibody levels remain for 17 years and have leveled-off over the past 7 years. Conclusion The two- and three-dose schedules provide similar protection >14 years after vaccination, indicating a booster dose is not needed at this time. Plateauing anti-HAV GMC levels suggest protective antibody levels may persist long-term. PMID:23470239
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okamoto, Masahiko, E-mail: masaoka@showa.gunma-u.ac.jp; Ishikawa, Hitoshi; Ebara, Takeshi
2012-02-01
Purpose: To determine the predictive risk factors for Grade 2 or worse rectal bleeding after high-dose-rate brachytherapy (HDR-BT) combined with hypofractionated external-beam radiotherapy (EBRT) for prostate cancer using dose-volume histogram analysis. Methods and Materials: The records of 216 patients treated with HDR-BT combined with EBRT were analyzed. The treatment protocols for HDR-BT were 5 Gy Multiplication-Sign five times in 3 days or 7 Gy Multiplication-Sign three, 10.5 Gy Multiplication-Sign two, or 9 Gy Multiplication-Sign two in 2 days. The EBRT doses ranged from 45 to 51 Gy with a fractional dose of 3 Gy. Results: In 20 patients Grade 2more » or worse rectal bleeding developed, and the cumulative incidence rate was 9% at 5 years. By converting the HDR-BT and EBRT radiation doses into biologic effective doses (BED), the BED{sub 3} at rectal volumes of 5% and 10% in the patients who experienced bleeding were significantly higher than those in the remaining 196 patients. Univariate analysis showed that a higher rectal BED{sub 3-5%} and the use of fewer needles in brachytherapy were correlated with the incidence of bleeding, but BED{sub 3-5%} was found to be the only significant factor on multivariate analysis. Conclusions: The radiation dose delivered to small rectal lesions as 5% is important for predicting Grade 2 or worse rectal bleeding after HDR-BT combined with EBRT for prostate cancer.« less
Wang, Juan; Chen, Dan; Li, Da-Bing; Yu, Xin; Shi, Guo-Bing
2016-01-01
Abstract Background: Previous study indicated that high-dose statin treatment might increase the risk of hemorrhagic stroke and adverse reactions. We aim to compare the efficacy and safety of intensive-dose and standard-dose statin treatment for preventing stroke in high-risk patients. Methods: A thorough search was performed of multiple databases for publications from 1990 to June 2015. We selected the randomized clinical trials comparing standard-dose statin with placebo and intensive-dose statin with standard-dose statin or placebo for the prevention of stroke events in patients. Duplicate independent data extraction and bias assessments were performed. Data were pooled using a fixed-effects model or a random-effects model if significant heterogeneity was present. Results: For the all stroke incidences, intensive-dose statin treatment compared with placebo treatment and standard-dose statin treatment compared with placebo treatment showed a significant 21% reduction in relative risk (RR) (RR 0.79, 95% confidence interval (CI) [0.71, 0.87], P < 0.00001) and an 18% reduction in RR (RR 0.82, 95% CI [0.73, 0.93], P = 0.002) in the subgroup without renal transplant recipients and patients undergoing regular hemodialysis separately. For the fatal stroke incidences, intensive-dose statin treatment compared with standard dose or placebo was effective reducing fatal stroke (RR 0.61, 95% CI [0.39, 0.96], P = 0.03) and the RR was 1.01 (95% CI [0.85, 1.20], P = 0.90) in standard-dose statin treatment compared with placebo. Conclusion: The results of this meta-analysis suggest that intensive-dose statin treatment might be more favorable for reducing the incidences of all strokes than standard-dose statin treatment, especially for patients older than 65 years in reducing the incidences of all stroke incidences. PMID:27684837
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Alexandra J.; Cormack, Robert A.; Lee, Hang
2008-11-01
Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladdermore » were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Y; Department of Engineering Physics, Tsinghua University, Beijing; Tian, Z
Purpose: Acuros BV has become available to perform accurate dose calculations in high-dose-rate (HDR) brachytherapy with phantom heterogeneity considered by solving the Boltzmann transport equation. In this work, we performed validation studies regarding the dose calculation accuracy of Acuros BV in cases with a shielded cylinder applicator using Monte Carlo (MC) simulations. Methods: Fifteen cases were considered in our studies, covering five different diameters of the applicator and three different shielding degrees. For each case, a digital phantom was created in Varian BrachyVision with the cylinder applicator inserted in the middle of a large water phantom. A treatment plan withmore » eight dwell positions was generated for these fifteen cases. Dose calculations were performed with Acuros BV. We then generated a voxelized phantom of the same geometry, and the materials were modeled according to the vendor’s specifications. MC dose calculations were then performed using our in-house developed fast MC dose engine for HDR brachytherapy (gBMC) on a GPU platform, which is able to simulate both photon transport and electron transport in a voxelized geometry. A phase-space file for the Ir-192 HDR source was used as a source model for MC simulations. Results: Satisfactory agreements between the dose distributions calculated by Acuros BV and those calculated by gBMC were observed in all cases. Quantitatively, we computed point-wise dose difference within the region that receives a dose higher than 10% of the reference dose, defined to be the dose at 5mm outward away from the applicator surface. The mean dose difference was ∼0.45%–0.51% and the 95-percentile maximum difference was ∼1.24%–1.47%. Conclusion: Acuros BV is able to accurately perform dose calculations in HDR brachytherapy with a shielded cylinder applicator.« less
Barrios, V; Escobar, C; de la Figuera, M; Honorato, J; Llisterri, J L; Segura, J; Calderón, A
2008-01-01
Aims/Introduction The TOlerabilidad de LERcanidipino 20 mg frente a Amlodipino y Nifedipino en CondicionEs normales de uso study was aimed to compare the tolerability of high doses of lercanidipine with amlodipine and nifedipine gastro-intestinal therapeutic system (GITS) in the treatment of hypertension in daily clinical practice. Patients/methods Essential hypertensives ≥ 18 years, treated during at least 1 month with lercanidipine 20 mg, amlodipine 10 mg or nifedipine GITS 60 mg, after a previous treatment course of at least 1 month with half the dose of the corresponding drugs were included. We present the data of the subgroup of patients with metabolic syndrome (MetS). Results Three hundred and thirty-seven of the 650 study population fulfilled criteria of MetS, 233 (69.1%) on lercanidipine and 104 (30.9%) on amlodipine/nifedipine GITS. Overall, a significantly lower proportion of lercanidipine-treated patients showed adverse reactions (ARs) when compared with patients receiving other-dihydropyridines (DHPs) (60.1% vs. 73.1%, p = 0.003). Similarly, the most common vasodilation-related ARs (oedema, swelling, flushing and headache) were significantly less frequent in lercanidipine group (all p < 0.01). Conclusion In conclusion, lercanidipine appears to exhibit a better tolerability profile and less vasodilation-related ARs compared with other DHPs in hypertensive patients with MetS. PMID:18355238
WE-EF-BRA-06: Feasibility of Spatially Modulated Proton Beams for Small Animal Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, E; Meyer, J
Purpose: To investigate the feasibility of proton minibeam radiotherapy (pMBRT) for small animal research. The motivation is to explore with protons the extraordinary normal tissue sparing effects to spatially modulated beams as observed on high flux synchrotron beam lines. We hypothesized that we can design a multi-slit collimator for our proton beam line to produce planar-parallel dose profiles with high modulation in the entrance region and homogenous dose coverage in the overlap of the Bragg peaks. Methods: The high dose rate 50 MeV research proton beamline at the University of Washington was modeled using the TOol for PArticle Simulation (TOPAS)more » Monte Carlo package. A brass collimator was implemented to generate proton minibeams. The collimator consists of an array of 2 cm long slits to cover an area of 2×2 cm{sup 2}. The slit widths (0.1–1 mm), center-to-center (ctc) distances (1–3 mm) and collimator thickness (1–7 cm) were varied to evaluate the effect on dose rate, the peak-to-valley dose ratios (PVDR) and the change of penumbra and peak width (FWHM) with depth. Results: The Bragg peak was at a depth of ∼21 mm. The penumbra and FWHM remained relatively constant to a depth of about 10–15 mm. The PVDR ranged from 1.6 to 26 and the dose rate dropped exponentially with collimator thickness. A uniform dose can be achieved at depth with slightly compromised PVDRs and dose rate. Conclusion: The technical realization of pMBRT is feasible. The simulations have shown that it is possible to obtain uniform dose at depth while modulation is maintained on the entrance side. While the simulated beam widths are larger than on synchrotron generated microbeams the dosimetric advantage could avoid having to interlace two microbeams to achieve uniform dose in the target. The next steps are to build a collimator and verify the simulations experimentally.« less
Adewale, Osonuga Odusoga; Oduyemi, Osonuga Ifabunmi; Ayokunle, Osonuga
2014-01-01
Objective To determine the effect of graded doses of aqueous leaf extracts of Momordica charantia on fertility hormones of female albino rats. Methods Twenty adult, healthy, female Wistar rats were divided into four groups: low dose (LD), moderate dose (MD) and high dose (HD) groups which received 12.5 g, 25.0 g, 50.0 g of the leaf extract respectively and control group that was given with water ad libatum. Result Estrogen levels reduced by 6.40 nmol/L, 10.80 nmol/L and 28.00 nmol/L in the LD, MD and HD groups respectively while plasma progesterone of rats in the LD, MD and HD groups reduced by 24.20 nmol/L, 40.8 nmol/L and 59.20 nmol/L respectively. Conclusion Our study has shown that the antifertility effect of Momordica charantia is achieved in a dose dependent manner. Hence, cautious use of such medication should be advocated especially when managing couples for infertility. PMID:25183143
High-dose anti-histamine use and risk factors in children with urticaria
Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu
2016-01-01
Aim The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. Material and Methods The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. Results The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p<0.0001). There was no difference between the two groups in terms of blood eosinophil and basophil counts, and serum total IgE levels (p>0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=−0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03–1.15]) and basopenia (OR: 6.77; CI 95%: [2.01–22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. Conclusion The requirement of high-dose H1-antihistamines was higher with children’s increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines. PMID:28123332
Uchiwa, Hiroki; Kai, Hisashi; Iwamoto, Yoshiko; Anegawa, Takahiro; Kajimoto, Hidemi; Fukuda, Kenji; Imaizumi, Tsutomu; Fukumoto, Yoshihiro
2018-01-01
Morning hypertension is an independent risk for cerebrovascular and cardiovascular events. Although the prevalence of morning hypertension increases with age, treatment of morning hypertension has not been established, particularly in Very-Elderly patients. We compared the safety and efficacy of a losartan/hydrochlorothiazide (HCTZ) combination in controlling morning hypertension between Very-Elderly (≥75 years) and Young/Elderly patients (<75 years). This study was a subanalysis of the Morning Hypertension and Angiotensin Receptor Blocker/Hydrochlorothiazide Combination Therapy study, in which patients with morning hypertension (≥135/85 mmHg) received a 50-mg losartan/12.5-mg HCTZ combination tablet (combination therapy) or 100-mg losartan (high-dose therapy) for 3 months. High adherence rates and few adverse effects were observed in Very-Elderly patients receiving combination (n = 32) and high-dose (n = 34) therapies and in Young/Elderly patients receiving combination (n = 69) and high-dose (n = 66) therapies. Baseline morning systolic BP (SBP) was similar in both age groups receiving either therapy. Morning SBP was reduced by 20.2 and 18.1 mmHg with combination therapy and by 7.1 and 9.1 mmHg with high-dose therapy in the Very-Elderly and Young/Elderly patients, respectively. Morning BP target (<135/85 mmHg) was achieved in 40.6% and 55.1% by combination therapy and in 14.7% and 24.2% by high-dose therapy in the Very-Elderly and Young/Elderly patients, respectively. Neither therapy changed renal function and serum potassium in Very-Elderly patients. In conclusion, the losartan/HCTZ combination was safe and effective in controlling morning hypertension in Very-Elderly as well as Young/Elderly patients. In addition, combination therapy was also superior to high-dose therapy for lowering morning SBP in Very-Elderly patients.
Wilson, Jolaine M.; Sanzari, Jenine K.; Diffenderfer, Eric S.; Yee, Stephanie S.; Seykora, John T.; Maks, Casey; Ware, Jeffrey H.; Litt, Harold I.; Reetz, Jennifer A.; McDonough, James; Weissman, Drew; Kennedy, Ann R.; Cengel, Keith A.
2011-01-01
In a solar particle event (SPE), an unshielded astronaut would receive proton radiation with an energy profile that produces a highly inhomogeneous dose distribution (skin receiving a greater dose than internal organs). The novel concept of using megavoltage electron-beam radiation to more accurately reproduce both the total dose and the dose distribution of SPE protons and make meaningful RBE comparisons between protons and conventional radiation has been described previously. Here, Yucatan minipigs were used to determine the effects of a superficial, SPE-like proton dose distribution using megavoltage electrons. In these experiments, dose-dependent increases in skin pigmentation, ulceration, keratinocyte necrosis and pigment incontinence were observed. Five of 18 animals (one each exposed to 7.5 Gy and 12.5 Gy radiation and three exposed to 25 Gy radiation) developed symptomatic, radiation-associated pneumonopathy approximately 90 days postirradiation. The three animals from the highest dose group showed evidence of mycoplasmal pneumonia along with radiation pneumonitis. Moreover, delayed-type hypersensitivity was found to be altered, suggesting that superficial irradiation of the skin with ionizing radiation might cause immune dysfunction or dysregulation. In conclusion, using total doses, patterns of dose distribution, and dose rates that are compatible with potential astronaut exposure to SPE radiation, animals experienced significant toxicities that were qualitatively different from toxicities previously reported in pigs for homogeneously delivered radiation at similar doses. PMID:21859326
Jae, Hwan Jun; Park, Hee Sun; Lee, Min Jong; Lee, Ki Chang; Kim, Hyo-Cheol; Yoon, Jung Hwan; Chung, Hesson; Park, Jae Hyung
2009-01-01
Objective The purpose of this study was to compare the antitumor effect and hepatotoxicity of an intraarterial delivery of low-dose and high-dose 3-bromopyruvate (3-BrPA) and those of a conventional Lipiodol-doxorubicin emulsion in a rabbit VX2 hepatoma model. Materials and Methods This experiment was approved by the animal care committee at our institution. VX2 carcinoma was implanted in the livers of 36 rabbits. Transcatheter intraarterial administration was performed using low dose 3-BrPA (25 mL in a 1 mM concentration, n = 10), high dose 3-BrPA (25 mL in a 5 mM concentration, n = 10) and Lipiodol-doxorubicin emulsion (1.6 mg doxorubicin/ 0.4 mL Lipiodol, n = 10), and six rabbits were treated with normal saline alone as a control group. One week later, the proportion of tumor necrosis was calculated based on histopathologic examination. The hepatotoxicity was evaluated by biochemical analysis. The differences between these groups were statistically assessed with using Mann-Whitney U tests and Kruskal-Wallis tests. Results The tumor necrosis rate was significantly higher in the high dose group (93% ± 7.6 [mean ± SD]) than that in the control group (48% ± 21.7) (p = 0.0002), but the tumor necrosis rate was not significantly higher in the low dose group (62% ± 20.0) (p = 0.2780). However, the tumor necrosis rate of the high dose group was significantly lower than that of the Lipiodol-doxorubicin treatment group (99% ± 2.7) (p = 0.0015). The hepatotoxicity observed in the 3-BrPA groups was comparable to that of the Lipiodol-doxorubicin group. Conclusion Even though intraarterial delivery of 3-BrPA shows a dose-related antitumor effect, single session treatment seems to have limited efficacy when compared with the conventional method. PMID:19885316
Restellini, Sophie; Kherad, Omar; Menard, Charles; Martel, Myriam; Barkun, Alan N
2018-02-01
BACKGROUND AND STUDY AIMS : Recommendations on adjuvant use with bowel preparations remain disparate. We performed a meta-analysis determining the clinical impact of adding an adjuvant to polyethylene glycol (PEG), sodium phosphate, picosulfate (PICO), or oral sulfate solutions (OSS)-based regimens. Systematic searches were made of MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials from January 1980 to April 2016 that assessed preparations with or without adjuvants, given in split and non-split dosing, and PEG high- (> 3 L) or low-dose (≤ 2 L) regimens. Bowel cleansing efficacy was the primary outcome. Secondary outcomes included patient willingness to repeat the procedure, and polyp and adenoma detection rates. Of 3093 citations, 77 trials fulfilled the inclusion criteria. Overall, addition of an adjuvant compared with no adjuvant, irrespective of the type of preparation and mode of administration, yielded improvements in bowel cleanliness (odds ratio [OR] 1.23 [1.01 - 1.51]) without greater willingness to repeat (OR 1.40 [0.91 - 2.15]). Adjuvants combined with high-dose PEG significantly improved colon cleansing (OR 1.96 [1.32 - 2.94]). The odds for achieving adequate preparation with low-dose PEG with an adjuvant were not different to high-dose PEG alone (OR 0.95 [0.73 - 1.22]), but yielded improved tolerance (OR 3.22 [1.85 - 5.55]). However, split high-dose PEG yielded superior cleanliness to low-dose PEG with adjuvants (OR 2.53 [1.25 - 5.13]). No differences were noted for OSS and PICO comparisons, or for any products regarding polyp or adenoma detection rates. Critical heterogeneity precludes firm conclusion on the impact of adjuvants with existing bowel preparations. Additional research is required to better characterize the methods of administration and resulting roles of adjuvants in an era of split-dosing. © Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Y; Cho, B; Kwak, J
2014-06-01
Purpose: We implemented the Gafchromic film-based patient specific QA of volumetric modulated arc therapy (VMAT) with flattening-filter free (FFF) beams for spine metastases and validated the accuracy of fast arc delivery. Methods: EBT3 films and a homemade cylindrical QA phantom were employed for dosimetric verification of VMATs. For 14 FFF VMAT plans (10 with 10-MV FFF beams and 4 with 6-MV FFF beams), the doses were recalculated on the phantom and delivered by a TrueBeam STx accelerator equipped with a high-definition 120 leaf MLC. The EBT3 films were scanned using an Epson 10000XL scanner through the FilmQA Pro software. Allmore » the irradiated film images were converted to dose map using a calibration response curve. The resulting dose map of film measurement was compared with treatment plan and evaluated using gamma analysis with dose tolerance of 2% within 2 mm. In addition, the point-dose measurement in the phantom using an ion chamber was evaluated as a reference in a ratio of measured and planned doses. Results: The gamma pass rates averaged over all FFF plans for composite-field measurements were 96.0 ± 3.6% (88.9%–99.5%). When adopting a tolerance level of 3% - 3 mm, the gamma pass rates were improved with the ranges from 98% to 100%. In addition, dose profiles and dose distributions showed that spinal cord was protected by the rapid dose fall-off and by delivering the treatment with high precision. In point-dose measurements, the average differences between the measured and planned doses were 0.5% ± 1.0% of the prescription dose. Conclusion: We demonstrated that Gafchromic EBT3 film would be an effective patient-specific QA tool, especially for VMAT of spine SBRT with treatment of small fields and highly gradient dose distributions. The results of film QA verified that the dosimetric accuracy of spine SBRT utilizing RapidArc with FFF beams in our institution is reliable.« less
Whale, Christopher I; Sovani, Milind P; Mortimer, Kevin J; Harrison, Timothy W; Tattersfield, Anne E
2008-01-01
AIMS Rac-formoterol is effective as maintenance treatment for both asthma and chronic obstructive pulmonary disease (COPD) and is now used as relief therapy in asthma. Using rac-formoterol for relief and maintenance treatment could involve inhalation of high doses, and whether this is of benefit in COPD is uncertain. Our aim was to determine whether higher doses of inhaled rac-formoterol produce systemic adverse effects that outweigh the limited bronchodilator benefit seen in subjects with COPD. METHODS We examined airway and systemic effects of 6, 12, 24 and 48 μg rac-formoterol and placebo on separate days in 20 subjects with symptomatic COPD [forced expiratory volume in 1 s (FEV1) 47% predicted]. FEV1, oxygen saturation, dyspnoea, 6-min walk distance, patient satisfaction and systemic effects were measured and treatment was assessed against placebo and for dose–response effects. RESULTS FEV1[area under the time–response curve (AUC)] and satisfaction scores increased with all formoterol doses compared with placebo, as did AUC tremor with the 24- and 48-μg doses and AUC heart rate with the 48-μg dose. A dose–response relationship was seen with FEV1 and tremor, but not with satisfaction scores. There was no difference between placebo and rac-formoterol for other variables. CONCLUSIONS Our results show that in patients with COPD rac-formoterol improves FEV1 and patient satisfaction without a corresponding reduction in dyspnoea. Since the systemic effects from a relatively high dose were minimal, its use as relief medication in COPD merits further evaluation. WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT The long-acting inhaled β2-agonist formoterol has systemic effects when taken in high doses. It can be used as relief medication in asthma and there is interest in this approach in chronic obstructive pulmonary disease (COPD). Relief medication can involve high doses, and in subjects with COPD who have limited ability to bronchodilate the adverse effects can outweigh the benefits. There are concerns with the overall safety of high-dose β2-agonists in subjects with COPD, and this study looks at the balance of beneficial and adverse effects of a range of doses of inhaled formoterol. WHAT THIS STUDY ADDS Among subjects with COPD, high-dose inhaled formoterol produced a dose-related increase in forced expiratory volume in 1 s without a corresponding reduction in dyspnoea or increase in walk distance.Systemic effects were modest, however, and high doses did not appear to reduce patient satisfaction.Although further safety data are needed, inhaled formoterol may have a role as relief medication in COPD. PMID:18394012
2013-01-01
Introduction Immune thrombocytopenic purpura is thought to be characterized by an immune response against the host’s own platelets. If the thrombocytopenia is severe, patients are initially treated with high-dose steroids. Other more toxic second line treatments are considered if steroids fail. Here, we report the case of two patients in whom conventional treatment was unsuccessful but who responded to hydroxychloroquine and high-dose vitamin D replacement therapy. To the best of our knowledge, this is the first description of successful treatment for immune thrombocytopenia with high-dose vitamin D and hydroxychloroquine. Case presentation Case 1: We report the case of a 79-year-old Caucasian man who presented with high titer antinuclear antibodies, positive anti-SSA/Ro autoantibodies and clinically was felt to have an overlap of systemic lupus erythematosus and/or Sjögren’s syndrome with profound life-threatening thrombocytopenia. There was no evidence of underlying malignancy. The patient’s platelet count significantly increased with vitamin D and hydroxychloroquine treatment, but upon vitamin D discontinuation his platelet levels plummeted. Hydroxychloroquine therapy was maintained throughout treatment. With reinstitution of high-dose vitamin D therapy, platelet counts were restored to normal levels. Case 2: We also report the case of an 87-year-old Caucasian woman who presented with high titer antinuclear antibodies, positive anti-SSA/Ro autoantibodies and was felt to have an overlap of systemic lupus erythematosus and/or Sjögren’s syndrome with immune thrombocytopenia; she also had severely low levels of 25-hydroxy vitamin D (17ng/mL). There was no evidence of underlying malignancy. She responded to high-dose vitamin D replacement and hydroxychloroquine treatment, thereby alleviating the need for high-dose steroid treatment. She remains in remission while taking vitamin D, hydroxychloroquine and very low-dose prednisone. No untoward side effects were observed in either patient. Conclusions In our two case reports, we found an association between vitamin D deficiency and immune thrombocytopenia where platelet levels responded to vitamin D treatment and hydroxychloroquine but not to prednisone. We believe there may be synergism between vitamin D supplementation and hydroxychloroquine. The mechanism by which high-dose vitamin D results in increased platelet counts in immune thrombocytopenia patients is unknown. However, vitamin D has long been thought to play an immunomodulatory role, which may include a dampened immune response in patients with immune thrombocytopenia or other autoimmune diseases. PMID:23556539
Acute toxicity study of tilmicosin-loaded hydrogenated castor oil-solid lipid nanoparticles
2011-01-01
Background Our previous studies demonstrated that tilmicosin-loaded hydrogenated castor oil solid lipid nanoparticles (Til-HCO-SLN) are a promising formulation for enhanced pharmacological activity and therapeutic efficacy in veterinary use. The purpose of this work was to evaluate the acute toxicity of Til-HCO-SLN. Methods Two nanoparticle doses were used for the study in ICR mice. The low dose (766 mg/kg.bw) with tilmicosin 7.5 times of the clinic dosage and below the median lethal dose (LD50) was subcutaneously administered twice on the first and 7th day. The single high dose (5 g/kg.bw) was the practical upper limit in an acute toxicity study and was administered subcutaneously on the first day. Blank HCO-SLN, native tilmicosin, and saline solution were included as controls. After medication, animals were monitored over 14 days, and then necropsied. Signs of toxicity were evaluated via mortality, symptoms of treatment effect, gross and microscopic pathology, and hematologic and biochemical parameters. Results After administration of native tilmicosin, all mice died within 2 h in the high dose group, in the low dose group 3 died after the first and 2 died after the second injections. The surviving mice in the tilmicosin low dose group showed hypoactivity, accelerated breath, gloomy spirit and lethargy. In contrast, all mice in Til-HCO-SLN and blank HCO-SLN groups survived at both low and high doses. The high nanoparticle dose induced transient clinical symptoms of treatment effect such as transient reversible action retardation, anorexy and gloomy spirit, increased spleen and liver coefficients and decreased heart coefficients, microscopic pathological changes of liver, spleen and heart, and minor changes in hematologic and biochemical parameters, but no adverse effects were observed in the nanoparticle low dose group. Conclusions The results revealed that the LD50 of Til-HCO-SLN and blank HCO-SLN exceeded 5 g/kg.bw and thus the nanoparticles are considered low toxic according to the toxicity categories of chemicals. Moreover, HCO-SLN significantly decreased the toxicity of tilmicosin. Normal clinic dosage of Til-HCO-SLN is safe as evaluated by acute toxicity. PMID:22098626
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Xiaopei, E-mail: shix22@mcmaster.ca; Mothersi
Purpose: To determine whether chronic low-dose α-particle radiation from Ra-226 over multiple cell generations can lead to an adaptive response in CHSE/F fish embryonic cells or HaCaT human epithelial cells receiving subsequent acute high-dose γ-ray radiation. Methods: CHSE/F and HaCaT cells were exposed to very low doses of Ra-226 in medium for multiple generations prior to being challenged by a higher dose γ-ray radiation. The clonogenic assay was used to test the clonogenic survival of cells with or without being pretreated by radiation from Ra-226. Results: In general, pretreatment with chronic radiation has no significant influence on the reaction ofmore » cells to the subsequent challenge radiation. Compared to unprimed cells, the change in clonogenic survival of primed cells after receiving challenge radiation is mainly due to the influence of the chronic exposure, and there's little adaptive response induced. However at several dose points, pretreatment of CHSE/F fish cells with chronic radiation resulted in a radiosensitive response to a challenge dose of γ-ray radiation, and pretreatment of HaCaT cells resulted in no effect except for a slightly radioresistant response to the challenge radiation which was not significant. Conclusion: The results suggest that chronic low-dose radiation is not effective enough to induce adaptive response. There was a difference between human and fish cells and it may be important to consider results from multiple species before making conclusions about effects of chronic or low doses of radiation in the environment. The term “radiosensitive” or “adaptive” make no judgment about whether such responses are ultimately beneficial or harmful. - Highlights: • No obvious adaptive response is induced by chronic low-dose radiation from Ra-226. • Priming radiation from Ra-226 sensitized CHSE/F cells to the challenge radiation. • Linear model is inconsistent with current work using chronic low-dose radiation.« less
SU-F-BRD-05: Robustness of Dose Painting by Numbers in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montero, A Barragan; Sterpin, E; Lee, J
Purpose: Proton range uncertainties may cause important dose perturbations within the target volume, especially when steep dose gradients are present as in dose painting. The aim of this study is to assess the robustness against setup and range errors for high heterogeneous dose prescriptions (i.e., dose painting by numbers), delivered by proton pencil beam scanning. Methods: An automatic workflow, based on MATLAB functions, was implemented through scripting in RayStation (RaySearch Laboratories). It performs a gradient-based segmentation of the dose painting volume from 18FDG-PET images (GTVPET), and calculates the dose prescription as a linear function of the FDG-uptake value on eachmore » voxel. The workflow was applied to two patients with head and neck cancer. Robustness against setup and range errors of the conventional PTV margin strategy (prescription dilated by 2.5 mm) versus CTV-based (minimax) robust optimization (2.5 mm setup, 3% range error) was assessed by comparing the prescription with the planned dose for a set of error scenarios. Results: In order to ensure dose coverage above 95% of the prescribed dose in more than 95% of the GTVPET voxels while compensating for the uncertainties, the plans with a PTV generated a high overdose. For the nominal case, up to 35% of the GTVPET received doses 5% beyond prescription. For the worst of the evaluated error scenarios, the volume with 5% overdose increased to 50%. In contrast, for CTV-based plans this 5% overdose was present only in a small fraction of the GTVPET, which ranged from 7% in the nominal case to 15% in the worst of the evaluated scenarios. Conclusion: The use of a PTV leads to non-robust dose distributions with excessive overdose in the painted volume. In contrast, robust optimization yields robust dose distributions with limited overdose. RaySearch Laboratories is sincerely acknowledged for providing us with RayStation treatment planning system and for the support provided.« less
SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, S; Ahmed, S; Ahmed, F
2016-06-15
Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and planmore » quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubicek, Gregory J.; Werner-Wasik, Maria; Machtay, Mitchell
Purpose: To evaluate the toxicity and response rate of bortezomib with concurrent radiotherapy and temozolomide in the treatment of patients with central nervous system malignancies. Patients and Methods: This open-label, dose-escalation, Phase I clinical study evaluated the safety of three dose levels of intravenously administered bortezomib (0.7, 1.0, and 1.3 mg/m{sup 2}/dose) on Days 1, 4, 8, and 11 of a 21-day cycle, in addition to concurrent radiotherapy and temozolomide at a daily dose of 75 mg/m{sup 2} starting on Day 1. The primary endpoint was dose-limiting toxicity, defined as any Grade 4-5 toxicity or Grade 3 toxicity directly attributablemore » to protocol treatment, requiring hospitalization and/or radiotherapy interruption. The secondary endpoints included feasibility, non-dose-limiting toxicity, and treatment response. Results: A total of 27 patients were enrolled, 23 of whom had high-grade glioma (10 recurrent and 13 newly diagnosed). No dose-limiting toxicities were noted in any dose group, including the highest (1.3 mg/m{sup 2}/dose). The most frequent toxicities were Grade 1 and 2 stomatitis, erythema, and alopecia. All 27 patients were evaluable for response. At a median follow-up of 15.0 months, 9 patients were still alive, with a median survival of 17.4 months for all patients and 15.0 months for patients with high-grade glioma. Conclusion: Bortezomib administered at its typical 'systemic' dose (1.3 mg/m{sup 2}) is well tolerated and safe combined with temozolomide and radiotherapy when used in the treatment of central nervous system malignancies. A Phase II study to characterize efficacy is warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, J; Xu, Z; Baker, J
Purpose: To compare three-dimensional conformal radiotherapy (3D CRT) and volumetric-modulated arc therapy (VMAT) in lung stereotactic body radiation therapy (SBRT) Methods: A retrospective study of clinically treated lung SBRT cases treated between 2010 and 2015 at our hospital was performed. All treatment modalities were included in this evaluation (VMAT, 3D CRT, static IMRT, and dynamic conformal arc therapy). However, the majority of treatment modalities were either VMAT or 3D CRT. Treatment times of patients and dosimetric plan quality metrics were compared. Treatment times were calculated based on the time the therapist opened and closed the patient’s treatment plan. This treatmentmore » time closely approximates the utilization time of the treatment room. The dosimetric plan quality metrics evaluated include ICRU conformity index, the volume of 105% prescribed dose outside PTV, the ratio of volume of 50% prescribed dose to the volume of PTV, the percentage of maximum dose at 2 cm away from PTV to the prescribed dose, and the V20 (percentage of lung volume receiving 20 Gy or more). Results: Treatment time comparisons show that on average VMAT has shorter treatment times than 3D CRT. Dose conformity, defined by the ICRU conformity index, and high dose spillage, defined by the volume of 105% dose outside the PTV, is reduced when using VMAT compared to 3D CRT. V20 and intermediate dose spillage/fall-off metrics of VMAT and 3D are not significantly different. Conclusion: Clinically treated lung SBRT cases indicate VMAT is superior to 3D with regard to shorter treatment times, plan dose conformity, and plan high dose spillage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nose, Takayuki; Department of Physics, Cancer Institute of the Japanese Foundation for Cancer Research, Tokyo; Koizumi, Masahiko
2008-02-01
Purpose: To perform the largest in vivo dosimetry study for interstitial brachytherapy yet to be undertaken using a new radiophotoluminescence glass dosimeter (RPLGD) in patients with pelvic malignancy and to study the limits of contemporary planning software based on the results. Patients and Methods: Sixty-six patients with pelvic malignancy were treated with high-dose-rate interstitial brachytherapy, including prostate (n = 26), gynecological (n = 35), and miscellaneous (n = 5). Doses for a total of 1004 points were measured by RPLGDs and calculated with planning software in the following locations: rectum (n = 549), urethra (n = 415), vagina (n =more » 25), and perineum (n = 15). Compatibility (measured dose/calculated dose) was analyzed according to dosimeter location. Results: The compatibility for all dosimeters was 0.98 {+-} 0.23, stratified by location: rectum, 0.99 {+-} 0.20; urethra, 0.96 {+-} 0.26; vagina, 0.91 {+-} 0.08; and perineum, 1.25 {+-} 0.32. Conclusions: Deviations between measured and calculated doses for the rectum and urethra were greater than 20%, which is attributable to the independent movements of these organs and the applicators. Missing corrections for inhomogeneity are responsible for the 9% negative shift near the vaginal cylinder (specific gravity = 1.24), whereas neglect of transit dose contributes to the 25% positive shift in the perineal dose. Dose deviation of >20% for nontarget organs should be taken into account in the planning process. Further development of planning software and a real-time dosimetry system are necessary to use the current findings and to achieve adaptive dose delivery.« less
SU-E-T-183: Feasibility of Extreme Dose Escalation for Glioblastoma Multiforme Using 4π Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, D; Rwigema, J; Yu, V
Purpose: GBM recurrence primarily occurs inside or near the high-dose radiation field of original tumor site requiring greater than 100 Gy to significantly improve local control. We utilize 4π non-coplanar radiotherapy to test the feasibility of planning target volume (PTV) margin expansions or extreme dose escalations without incurring additional radiation toxicities. Methods: 11 GBM patients treated with VMAT to a prescription dose of 59.4 Gy or 60 Gy were replanned with 4π. Original VMAT plans were created with 2 to 4 coplanar or non-coplanar arcs using 3 mm hi-res MLC. The 4π optimization, using 5 mm MLC, selected and inversemore » optimized 30 beams from a candidate pool of 1162 beams evenly distributed through 4π steradians. 4π plans were first compared to clinical plans using the same prescription dose. Two more studies were then performed to respectively escalate the GTV and PTV doses to 100 Gy, followed by a fourth plan expanding the PTV by 5 mm and maintaining the prescription dose. Results: The standard 4π plan significantly reduced (p<0.01) max and mean doses to critical structures by a range of 47.0–98.4% and 61.0–99.2%, respectively. The high dose PTV/high dose GTV/expanded PTV studies showed a reduction (p<0.05) or unchanged* (p>0.05) maximum dose of 72.1%/86.7%/77.1% (chiasm), 7.2%*/27.7%*/30.7% (brainstem), 39.8%*/84.2%/51.9%* (spinal cord), 69.0%/87.0%/66.9% (L eye), 76.2%/88.1%/84.1% (R eye), 95.0%/98.6%/97.5% (L lens), 93.9%/98.8%/97.6% (R lens), 74.3%/88.5%/72.4% (L optical nerve), 80.4%/91.3%/75.7% (R optical nerve), 64.8%/84.2%/44.9%* (L cochlea), and 85.2%/93.0%/78.0% (R cochlea), respectively. V30 and V36 for both brain and (brain - PTV) were reduced for all cases except the high dose PTV plan. PTV dose coverage increased for all 4π plans. Conclusion: Extreme dose escalation or further margin expansion is achievable using 4π, maintaining or reducing OAR doses. This study indicates that clinical trials employing 4π delivery using prescription doses up to 100 Gy are feasible. Funding support partially contributed by Varian.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, S; Department of Biomedical Engineering, University of North Carolina- Chapel Hill/ North Carolina State University, Chapel Hill, North Carolina; Lineberger Clinical Cancer Center, University of North Carolina, Chapel Hill, NC
Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression andmore » cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russo, James K.; Armeson, Kent E.; Richardson, Susan, E-mail: srichardson@radonc.wustl.edu
2012-05-01
Purpose: To evaluate bladder and rectal doses using two-dimensional (2D) and 3D treatment planning for vaginal cuff high-dose rate (HDR) in endometrial cancer. Methods and Materials: Ninety-one consecutive patients treated between 2000 and 2007 were evaluated. Seventy-one and 20 patients underwent 2D and 3D planning, respectively. Each patient received six fractions prescribed at 0.5 cm to the superior 3 cm of the vagina. International Commission on Radiation Units and Measurements (ICRU) doses were calculated for 2D patients. Maximum and 2-cc doses were calculated for 3D patients. Organ doses were normalized to prescription dose. Results: Bladder maximum doses were 178% ofmore » ICRU doses (p < 0.0001). Two-cubic centimeter doses were no different than ICRU doses (p = 0.22). Two-cubic centimeter doses were 59% of maximum doses (p < 0.0001). Rectal maximum doses were 137% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 87% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 64% of maximum doses (p < 0.0001). Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final bladder dose to within 10% for 44%, 59%, 83%, 82%, and 89% of patients by using the ICRU dose, and for 45%, 55%, 80%, 85%, and 85% of patients by using the maximum dose, and for 37%, 68%, 79%, 79%, and 84% of patients by using the 2-cc dose. Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final rectal dose to within 10% for 100%, 100%, 100%, 100%, and 100% of patients by using the ICRU dose, and for 60%, 65%, 70%, 75%, and 75% of patients by using the maximum dose, and for 68%, 95%, 84%, 84%, and 84% of patients by using the 2-cc dose. Conclusions: Doses to organs at risk vary depending on the calculation method. In some cases, final dose accuracy appears to plateau after the third fraction, indicating that simulation and planning may not be necessary in all fractions. A clinically relevant level of accuracy should be determined and further research conducted to address this issue.« less
Stereotactic body radiation therapy for abdominal oligometastases: a biological and clinical review
2012-01-01
Advances in imaging and biological targeting have led to the development of stereotactic body radiation therapy (SBRT) as an alternative treatment of extracranial oligometastases. New radiobiological concepts, such as ceramide-induced endothelial apoptosis after hypofractionated high-dose SBRT, and the identification of patients with oligometastatic disease by microRNA expression may yet lead to further developments. Key factors in SBRT are delivery of a high dose per fraction, proper patient positioning, target localisation, and management of breathing–related motion. Our review addresses the radiation doses and schedules used to treat liver, abdominal lymph node (LN) and adrenal gland oligometastases and treatment outcomes. Reported local control (LC) rates for liver and abdominal LN oligometastases are high (median 2-year actuarial LC: 61 -100% for liver oligometastases; 4-year actuarial LC: 68% in a study of abdominal LN oligometastases). Early toxicity is low-to-moderate; late adverse effects are rare. SBRT of adrenal gland oligometastases shows promising results in the case of isolated lesions. In conclusion, properly conducted SBRT procedures are a safe and effective treatment option for abdominal oligometastases. PMID:22852764
Ghorbani, Mahdi; Toossi, Mohammad Taghi Bahreyni; Mowlavi, Ali Asghar; Roodi, Shahram Bayani; Meigooni, Ali Soleimani
2012-01-01
Background. The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. Materials and methods A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 60Co brachytherapy source with GafChromic® EBT radiochromic films. In these investigations, the non-uniformity of the film and scanner response, combined, as well as the films sensitivity to scanner’s light source was evaluated using multiple samples of films, prior to the source dosimetry. The results of these measurements were compared with the Monte Carlo simulated data using MCNPX code. In addition, isodose curves acquired by radiochromic films and Monte Carlo simulation were compared with those provided by the GZP6 treatment planning system. Results Scanning of samples of uniformly irradiated films demonstrated approximately 2.85% and 4.97% nonuniformity of the response, respectively in the longitudinal and transverse directions of the film. Our findings have also indicated that the film response is not affected by the exposure to the scanner’s light source, particularly in multiple scanning of film. The results of radiochromic film measurements are in good agreement with the Monte Carlo calculations (4%) and the corresponding dose values presented by the GZP6 treatment planning system (5%). Conclusions The results of these investigations indicate that the Microtek ScanMaker 1000XL color scanner in conjunction with GafChromic EBT film is a reliable system for dosimetric evaluation of a high dose rate brachytherapy source. PMID:23411947
Zeng, Zhikai; Li, Qingyun; Tian, Qiyu; Zhao, Panfeng; Xu, Xiao; Yu, Shukun; Piao, Xiangshu
2015-11-01
This study was conducted to evaluate the efficacy of a novel Buttiauxella phytase to pigs fed P-deficient, corn-soybean meal diets. One hundred and twenty crossbred piglets (9.53 ± 0.84 kg) were allocated to one of five treatments which consisted of four low P diets (0.61 % Ca and 0.46 % total P) supplemented with 0, 500, 1,000, or 20,000 FTU/kg phytase as well as a positive control diet (0.77 % Ca and 0.62 % total P). Each treatment had six replicated pens with four pigs per pen. Pigs were fed the experimental diets for 28 days. Phytase supplementation linearly improved (P < 0.05) average daily gain (ADG), feed conversion ratio (FCR), and apparent total tract digestibility (ATTD) of dry matter, gross energy, crude protein, Ca, and P in weaned pigs. Super high dosing with phytase (20,000 FTU/kg) further increased (P < 0.05) ADG compared with 500 FTU/kg phytase inclusion group, as well as ATTD of Ca and P. Metacarpal bone characteristics and several trace mineral concentration in bone, plasma, or organ tissues were linearly (P < 0.05) improved at increasing dose of phytase. Super high dosing with phytase (20,000 FTU/kg) supplementation improved (P < 0.05) Mn and Zn concentration in bone compared to normal dose of phytase supplementation (500 or 1,000 FTU/kg). In conclusion, supplementation of 500 FTU of Buttiauxella phytase/kg and above effectively hydrolyzed phytate in a low-P corn-soybean diet for pigs. In addition, a super high dosing with phytase (20,000 FTU/kg) improved macro- or micro mineral availability and growth performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hobbs, R; Le, Y; Armour, E
Purpose: Dose-response studies in radiation therapy are typically using single response values for tumors across ensembles of tumors. Using the high dose rate (HDR) treatment plan dose grid and pre- and post-therapy FDG-PET images, we look for correlations between voxelized dose and FDG uptake response in individual tumors. Methods: Fifteen patients were treated for localized rectal cancer using 192Ir HDR brachytherapy in conjunction with surgery. FDG-PET images were acquired before HDR therapy and 6–8 weeks after treatment (prior to surgery). Treatment planning was done on a commercial workstation and the dose grid was calculated. The two PETs and the treatmentmore » dose grid were registered to each other using non-rigid registration. The difference in PET SUV values before and after HDR was plotted versus absorbed radiation dose for each voxel. The voxels were then separated into bins for every 400 cGy of absorbed dose and the bin average values plotted similarly. Results: Individual voxel doses did not correlate with PET response; however, when group into tumor subregions corresponding to dose bins, eighty percent of the patients showed a significant positive correlation (R2 > 0) between PET uptake difference in the targeted region and the absorbed dose. Conclusion: By considering larger ensembles of voxels, such as organ average absorbed dose or the dose bins considered here, valuable information may be obtained. The dose-response correlations as measured by FDG-PET difference potentially underlines the importance of FDG-PET as a measure of response, as well as the value of voxelized information.« less
Vang, Sophia Ingeborg; Schmiegelow, Kjeld; Frandsen, Thomas; Rosthøj, Susanne; Nersting, Jacob
2015-05-01
High-dose methotrexate (HD-MTX) courses with concurrent oral low-dose MTX/6-mercaptopurine (6MP) for childhood acute lymphoblastic leukaemia (ALL) are often followed by neutro- and thrombocytopenia necessitating treatment interruptions. Plasma MTX during HD-MTX therapy guides folinic acid rescue to prevent toxicities, but myelosuppression can also be prevented by pre-HD-MTX 6MP dose reductions. Accordingly, we monitored pre-HD-MTX erythrocyte levels of methylated 6MP metabolites (Ery-MeMP) and of thioguanine nucleotides (Ery-6TGN) as well as DNA-incorporated thioguanine nucleotides (DNA-TGN) in circulating leucocytes to identify patients at highest risk of post-HD-MTX myelosuppression. In multiple linear regression analyses of neutrophil and thrombocyte nadir values (adjusted for gender, age, risk group and 6MP dose) after 48 HD-MTX courses in 17 childhood ALL patients on MTX/6MP maintenance therapy, the pre-HD-MTX DNA-TGN levels in neutrophils (P < 0.0001), Ery-MeMP (P < 0.0001) and Ery-6TGN (P = 0.01) levels were significant predictors of post-HD-MTX neutrophil nadirs, whereas Ery-MeMP (P < 0.0001) was the only predictor of post-HD-MTX thrombocyte nadir. In conclusion, pre-HD-MTX 6MP metabolite levels may be applicable for 6MP dose adjustments to prevent HD-MTX-induced myelosuppression.
Jin, Hongbo; Li, Wenling; Dong, Changzheng; Ma, Li; Wu, Jiang; Zhao, Wenqing
2016-01-01
Background This study was designed to investigate the effects of different doses of levetiracetam on aquaporin 4 (AQP4) expression in rats after fluid percussion injury. Material/Methods Sprague-Dawley rats were randomly divided into 4 groups: sham operation group, traumatic brain injury group, low-dose levetiracetam group, and high-dose levetiracetam group. Brain edema models were established by fluid percussion injury, and intervened by the administration of levetiracetam. Samples from the 4 groups were collected at 2, 6, 12, and 24 h, and at 3 and 7 days after injury. Histological observation was performed using hematoxylin-eosin staining and immunohistochemical staining. AQP4 and AQP4 mRNA expression was detected using Western blot assay and RT-PCR. Brain water content was measured by the dry-wet method. Results Compared with the traumatic brain injury group, brain water content, AQP4 expression, and AQP4 mRNA expression were lower in the levetiracetam groups at each time point and the differences were statistically significant (P<0.05). The intervention effects of high-dose levetiracetam were more apparent. Conclusions Levetiracetam can lessen brain edema from fluid percussion injury by down-regulating AQP4 and AQP4 mRNA expression. There is a dose-effect relationship in the preventive effect of levetiracetam within a certain extent. PMID:26927633
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D.W. Nathan; Cho, L. Chinsoo; Straka, Christopher
2014-07-01
Purpose: To convey the occurrence of isolated cases of severe rectal toxicity at the highest dose level tested in 5-fraction stereotactic body radiation therapy (SBRT) for localized prostate cancer; and to rationally test potential causal mechanisms to guide future studies and experiments to aid in mitigating or altogether avoiding such severe bowel injury. Methods and Materials: Clinical and treatment planning data were analyzed from 91 patients enrolled from 2006 to 2011 on a dose-escalation (45, 47.5, and 50 Gy in 5 fractions) phase 1/2 clinical study of SBRT for localized prostate cancer. Results: At the highest dose level, 6.6% ofmore » patients treated (6 of 91) developed high-grade rectal toxicity, 5 of whom required colostomy. Grade 3+ delayed rectal toxicity was strongly correlated with volume of rectal wall receiving 50 Gy >3 cm{sup 3} (P<.0001), and treatment of >35% circumference of rectal wall to 39 Gy (P=.003). Grade 2+ acute rectal toxicity was significantly correlated with treatment of >50% circumference of rectal wall to 24 Gy (P=.010). Conclusion: Caution is advised when considering high-dose SBRT for treatment of tumors near bowel structures, including prostate cancer. Threshold dose constraints developed from physiologic principles are defined, and if respected can minimize risk of severe rectal toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fallal, Mohammadi Gh.; Riyahi, Alam N.; Graily, Gh.
Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-systemmore » component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose. This work has been supported by the research chancellor of tehran university of medical sciences(tums), school of medicine, Tehran, Iran.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zapatero, Almudena, E-mail: azapatero.hlpr@salud.madrid.org; Garcia-Vicente, Feliciano; Martin de Vidales, Carmen
Purpose: To analyze long-term outcome and prognostic factors for high-risk prostate cancer defined by National Comprehensive Cancer Network criteria treated with high-dose radiotherapy and androgen deprivation in a single institution. Methods and Materials: A total of 306 patients treated between 1995 and 2007 in a radiation dose-escalation program fulfilled the National Comprehensive Cancer Network high-risk criteria. Median International Commission on Radiation Units and Measurements radiation dose was 78 Gy (range, 66.0-84.1 Gy). Long-term androgen deprivation (LTAD) was administered in 231 patients, short-term androgen deprivation (STAD) in 59 patients, and no hormones in 16 patients. The Phoenix (nadir plus 2 ng/mL)more » consensus definition was used for biochemical control. Multivariate analysis was performed to determine the independent prognostic impact of clinical and treatment factors. Median follow-up time was 64 months (range, 24-171 months). Results: The actuarial overall survival at 5 and 10 years was 95.7% and 89.8%, respectively, and the corresponding biochemical disease-free survival (bDFS) was 89.5% and 67.2%, respectively. Fourteen patients (4.6%) developed distant metastasis. Multivariate analysis showed that Gleason score >7 (p = 0.001), pretreatment prostate-specific antigen (PSA) level >20 ng/mL (p = 0.037), higher radiation dose (p = 0.005), and the use of adjuvant LTAD vs. STAD (p = 0.011) were independent prognostic factors affecting bDFS in high-risk disease. The 5-year bDFS for patients treated with LTAD plus radiotherapy dose >78 Gy was 97%. Conclusions: For high-risk patients the present series showed that the use of LTAD in conjunction with higher doses (>78 Gy) of radiotherapy was associated with improved biochemical tumor control. We observed that the presence of Gleason sum >7 and pretreatment PSA level >20 ng/mL in the same patient represents a 6.8 times higher risk of PSA failure. These men could be considered for clinical trials with addition of novel agents.« less
Loop diuretics for chronic heart failure: a foe in disguise of a friend?
Kapelios, Chris J; Malliaras, Konstantinos; Kaldara, Elisabeth; Vakrou, Stella; Nanas, John N
2018-01-01
Loop diuretics are recommended for relieving symptoms and signs of congestion in patients with chronic heart failure and are administered to more than 80% of them. However, several of their effects have not systematically been studied. Numerous cohort and four interventional studies have addressed the effect of diuretics on renal function; apart from one prospective study, which showed that diuretics withdrawal is accompanied by increase in some markers of early-detected renal injury, all others converge to the conclusion that diuretics receipt, especially in high doses is associated with increased rates of renal dysfunction. Although a long standing perception has attributed a beneficial effect to diuretics in the setting of chronic heart failure, many cohort studies support that their use, especially in high doses is associated with adverse outcome. Several studies have used propensity scores in order to match diuretic and non-diuretic receiving patients; their results reinforce the notion that diuretics use and high diuretics dose are true risk factors and not disease severity markers, as some have suggested. One small, randomized study has demonstrated that diuretics decrease is feasible and safe and accompanied by a better prognosis. In conclusion, until elegantly designed, randomized trials, powered for clinical endpoints answer the unsettled issues in the field, the use of diuretics in chronic heart failure will remain subject to physicians' preferences and biases and not evidence based. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Donald; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A
2017-10-01
This review summarizes the conclusions and recommendations of the new National Council on Radiation Protection and Measurements (NCRP) Commentary No. 26 guidance on radiation dose limits for the lens of the eye. The NCRP addressed radiation protection principles in respect to the lens of the eye, discussed the current understanding of eye biology and lens effects, reviewed and evaluated epidemiology, and assessed exposed populations with the potential for significant radiation exposures to the lens while suggesting monitoring and protection practices. Radiation-induced damage to the lens of the eye can include the loss of clarity resulting in opacification or clouding several years after exposure. The impact is highly dependent on the type of radiation, how the exposure of the lens was delivered, the genetic susceptibilities of the individual exposed, and the location of the opacity relative to the visual axis of the individual. The preponderance of epidemiological evidence suggests that lens damage could occur at lower doses than previously considered and the NCRP has determined that it is prudent to reduce the recommended annual lens of the eye occupational dose limit from an equivalent dose of 150 mSv to an absorbed dose of 50 mGy. Significant additional research is still needed in the following areas: comprehensive evaluation of the overall effects of ionizing radiation on the eye, dosimetry methodology and dose-sparing optimization techniques, additional high quality epidemiology studies, and a basic understanding of the mechanisms of cataract development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jani, Ashish; Shaikh, Fauzia; Barton, Sunjay
Purpose: To characterize the effects of high-dose radiation therapy (HDRT) on neuroblastoma tumor vasculature, including the endothelial cell (EC)–pericyte interaction as a potential target for combined treatment with antiangiogenic agents. Methods and Materials: The vascular effects of radiation therapy were examined in a xenograft model of high-risk neuroblastoma. In vivo 3-dimensional contrast-enhanced ultrasonography (3D-CEUS) imaging and immunohistochemistry (IHC) were performed. Results: HDRT significantly reduced tumor blood volume 6 hours after irradiation compared with the lower doses used in conventionally fractionated radiation. There was a 63% decrease in tumor blood volume after 12-Gy radiation compared with a 24% decrease after 2 Gy. Analysis ofmore » tumor vasculature by lectin angiography showed a significant loss of small vessel ends at 6 hours. IHC revealed a significant loss of ECs at 6 and 72 hours after HDRT, with an accompanying loss of immature and mature pericytes at 72 hours. Conclusions: HDRT affects tumor vasculature in a manner not observed at lower doses. The main observation was an early reduction in tumor perfusion resulting from a reduction of small vessel ends with a corresponding loss of endothelial cells and pericytes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rezaeian, N Hassan; Chi, Y; Tian, Z
Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3Dmore » anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Kino, A; Newman, B
2014-06-01
Purpose: To investigate the radiation dose for pediatric high pitch cardiac CTA Methods: A total of 14 cases were included in this study, with mean age of 6.2 years (ranges from 2 months to 15 years). Cardiac CTA was performed using a dual-source CT system (Definition Flash, Siemens). Tube voltage (70, 80 and 100kV) was chosen based on patient weight. All patients were scanned using a high-pitch spiral mode (pitch ranges from 2.5 to 3) with tube current modulation technique (CareDose4D, Siemens). For each case, the three dimensional dose distributions were calculated using a Monte Carlo software package (IMPACT-MC, CTmore » Image GmbH). Scanning parameters of each exam, including tube voltage, tube current, beamshaping filters, beam collimation, were defined in the Monte Carlo calculation. Tube current profile along projection angles was obtained from projection data of each tube, which included data within the over-scanning range along z direction. The volume of lungs was segmented out with CT images (3DSlicer). Lung doses of all patients were calculated and compared with CTDIvol, DLP, and SSDE. Results: The average (range) of CTDIvol, DLP and SSDE of all patients was 1.19 mGy (0.58 to 3.12mGy), 31.54 mGy*cm (12.56 to 99 mGy*cm), 2.26 mGy (1.19 to 6.24 mGy), respectively. Radiation dose to the lungs ranged from 0.83 to 4.18 mGy. Lung doses correlated with CTDIvol, DLP and SSDE with correlation coefficients(k) at 0.98, 0.93, and 0.99. However, for the cases with CTDIvol less than 1mGy, only SSDE preserved a strong correlation with lung doses (k=0.83), while much weaker correlations were found for CTDIvol (k=0.29) and DLP (k=-0.47). Conclusion: Lung doses to pediatric patients during Cardiac CTA were estimated. SSDE showed the most robust correlation with lung doses in contrast to CTDIvol and DLP.« less
Kilburn, Lindsay B.; Kocak, Mehmet; Schaedeli Stark, Franziska; Meneses-Lorente, Georgina; Brownstein, Carrie; Hussain, Sazzad; Chintagumpala, Murali; Thompson, Patrick A.; Gururangan, Sri; Banerjee, Anuradha; Paulino, Arnold C.; Kun, Larry; Boyett, James M.; Blaney, Susan M.
2013-01-01
Background We conducted a phase I study to estimate the maximum tolerated dose and describe the dose-limiting toxicities and pharmacokinetics of oral capecitabine rapidly disintegrating tablets given concurrently with radiation therapy to children with newly diagnosed brainstem or high-grade gliomas. Methods Children 3–21 y with newly diagnosed intrinsic brainstem or high-grade gliomas were eligible for enrollment. The starting dose was 500 mg/m2, given twice daily, with subsequent cohorts enrolled at 650 mg/m2 and 850 mg/m2 using a 3 + 3 phase I design. Children received capecitabine at the assigned dose daily for 9 wks starting from the first day of radiation therapy (RT). Following a 2-wk break, patients received 3 courses of capecitabine 1250 mg/m2 twice daily for 14 days followed by a 7-day rest. Pharmacokinetic sampling was performed in consenting patients. Six additional patients with intrinsic brainstem gliomas were enrolled at the maximum tolerated dose to further characterize the pharmacokinetic and toxicity profiles. Results Twenty-four patients were enrolled. Twenty were fully assessable for toxicity. Dose-limiting toxicities were palmar plantar erythroderma (grades 2 and 3) and elevation of alanine aminotransferase (grades 2 and 3). Systemic exposure to capecitabine and metabolites was similar to or slightly lower than predicted based on adult data. Conclusions Capecitabine with concurrent RT was generally well tolerated. The recommended phase II capecitabine dose when given with concurrent RT is 650 mg/m2, administered twice daily. A phase II study to evaluate the efficacy of this regimen in children with intrinsic brainstem gliomas is in progress (PBTC-030). PMID:23592571
Davis, Gary L; Nelson, David R; Terrault, Norah; Pruett, Timothy L; Schiano, Thomas D; Fletcher, Courtney V; Sapan, Christine V; Riser, Laura N; Li, Yufeng; Whitley, Richard J; Gnann, John W
2005-08-01
Chronic hepatitis C is the most common indication for liver transplantation, but viral recurrence is universal and progressive graft injury occurs in most recipients. Our aim was to assess the safety, pharmacokinetics (PK), and antiviral effects of high doses of a human hepatitis C antibody enriched immune globulin product (HCIG) in patients undergoing liver transplantation for chronic hepatitis C. This was a multicenter, randomized, open-label, controlled trial conducted at 4 transplant centers in the United States. A total of 18 patients with chronic hepatitis C, who underwent liver transplantation, were randomized to receive low-dose HCIG (75 mg/kg) or high-dose HCIG (200 mg/kg), or no treatment. A total of 17 infusions of HCIG were administered in each treated patient over 14 weeks using a time-dependent dosing strategy based on the PK of anti-hepatitis B immune globulin in liver transplant recipients. Hepatitis C virus levels, liver enzymes, and liver biopsies were obtained serially throughout the study period. PK profiles of HCV antibodies were determined on days 4, 10, and 98. HCIG infusions were safe and tolerated. The infusion rate could not be maximized because of symptoms for 18% to 30% of the doses. The half-life of HCIG was extremely short immediately after transplantation but was gradually prolonged. In the high-dose group, serum alanine aminotransferase (ALT) levels normalized in most subjects and no patient developed hepatic fibrosis. However, serum HCV RNA levels were not suppressed at either dose. In conclusion, HCIG, an anti-HCV enriched immune globulin product, appears to be safe in patients with chronic hepatitis C undergoing liver transplantation. Further studies are required to determine whether the drug has beneficial effects in this group of patients.
Chromosomal instability induced by heavy ion irradiation
NASA Technical Reports Server (NTRS)
Limoli, C. L.; Ponnaiya, B.; Corcoran, J. J.; Giedzinski, E.; Morgan, W. F.
2000-01-01
PURPOSE: To establish the dose-response relationship for the induction of chromosomal instability in GM10115 cells exposed to high-energy iron ions (1 GeV/nucleon, mean LET 146 keV/microm) and gold ions (11 GeV/nucleon, mean LET 1450 keV/microm). Past work has established that sparsely ionizing X-rays can induce a long-lived destabilization of chromosomes in a dose-dependent manner at an incidence of approximately 3% per gray. The present investigation assesses the capacity of High-Z and High-energy (HZE) particles to elicit this same endpoint. MATERIALS AND METHODS: Clonal populations derived from single progenitor cells surviving heavy-ion irradiation were analyzed cytogenetically to identify those clones showing a persistent destablization of chromosomes. RESULTS: Dose-response data, with a particular emphasis at low dose (< 1.0 Gy), indicate a frequency of approximately 4% per gray for the induction of chromosomal instability in clones derived from single progenitor cells surviving exposure to iron ions. The induction of chromosomal instability by gold ions was, however, less responsive to applied dose, as the observed incidence of this phenotype varied from 0 to 10% over 1-8 Gy. Both iron and gold ions gave dose-dependent increases in the yield of chromosomal aberrations (both chromosome- and chromatid-type) measured at the first mitosis following irradiation, as well as shoulderless survival curves having D0=0.87 and 1.1 Gy respectively. CONCLUSIONS: Based on the present dose-response data, the relative biological effectiveness of iron ions is 1.3 for the induction of chromosomal instability, and this indicates that heavy ions are only slightly more efficient than X-rays at eliciting this delayed phenotype.
Karschner, Erin L.; Darwin, W. David; Goodwin, Robert S.; Wright, Stephen; Huestis, Marilyn A.
2013-01-01
BACKGROUND Sativex®, a cannabis extract oromucosal spray containing Δ9-tetrahydrocannabinol (THC) and cannabidiol (CBD), is currently in phase III trials as an adjunct to opioids for cancer pain treatment, and recently received United Kingdom approval for treatment of spasticity. There are indications that CBD modulates THC’s effects, but it is unclear if this is due to a pharmacokinetic and/or pharmacodynamic interaction. METHODS Cannabis smokers provided written informed consent to participate in this randomized, controlled, double-blind, double-dummy institutional review board–approved study. Participants received 5 and 15 mg synthetic oral THC, low-dose (5.4 mg THC and 5.0 mg CBD) and high-dose (16.2 mg THC and 15.0 mg CBD) Sativex, and placebo over 5 sessions. CBD, THC, 11-hydroxy-THC, and 11-nor-9-carboxy-THC were quantified in plasma by 2-dimensional GC-MS. Lower limits of quantification were ≤0.25 μg/L. RESULTS Nine cannabis smokers completed all 5 dosing sessions. Significant differences (P < 0.05) in maximum plasma concentrations (Cmax) and areas under the curve from 0–10.5 h postdose (AUC0→10.5) for all analytes were found between low and high doses of synthetic THC and Sativex. There were no statistically significant differences in Cmax, time to maximum concentration or in the AUC0→10.5 between similar oral THC and Sativex doses. Relative bioavailability was calculated to determine the relative rate and extent of THC absorption; 5 and 15 mg oral THC bioavailability was 92.6% (13.1%) and 98.8% (11.0%) of low- and high-dose Sativex, respectively. CONCLUSION These data suggest that CBD modulation of THC’s effects is not due to a pharmacokinetic interaction at these therapeutic doses. PMID:21078841
PHASE II STUDY OF HIGH DOSE PHOTON/PROTON RADIOTHERAPY IN THE MANAGEMENT OF SPINE SARCOMAS
DeLaney, Thomas F.; Liebsch, Norbert J.; Pedlow, Francis X.; Adams, Judith; Dean, Susan; Yeap, Beow Y.; McManus, Patricia; Rosenberg, Andrew E.; Nielsen, G. Petur; Harmon, David C.; Spiro, Ira J.; Raskin, Kevin A.; Suit, Herman D.; Yoon, Sam S.; Hornicek, Francis J.
2009-01-01
Purpose Radiotherapy (XRT) for spine sarcomas is constrained by spinal cord, nerve, and viscera tolerance. Negative surgical margins are uncommon; hence, doses of ≥ 66 Gy are recommended. A Phase II clinical trial evaluated high dose photon/proton XRT for spine sarcomas. Materials/Methods Eligible patients had non-metastatic, thoracic, lumbar, and/or sacral spine/paraspinal sarcomas. Treatment included pre- and/or post-op photon/proton XRT +/- radical resection; patients with osteosarcoma and Ewing's sarcoma received chemotherapy. Shrinking fields delivered 50.4 cobalt Gray equivalent (GyRBE) to subclinical disease, 70.2 GyRBE to microscopic disease in the tumor bed, and 77.4 GyRBE to gross disease at 1.8 GyRBE q.d. Doses were reduced for radiosensitive histologies, concurrent chemoradiation, or when diabetes or autoimmune disease present. Spinal cord dose was limited to 63/54 GyRBE to surface/center. Intra-operative boost doses of 7.5-10 Gy could be given by dural plaque. Results 50 patients (29 chordoma, 14 chondrosarcoma, 7 other) underwent gross total (n=25) or subtotal (n=12) resection or biopsy (n=13). With 48 month median follow-up, five-year actuarial local control, recurrence-free survival, and overall survival are: 78%, 63%, and 87% respectively. Two of 36 (5.6%) patients treated for primary versus 7/14 (50%) for recurrent tumor developed local recurrence, p<0.001. Five patients developed late radiation-associated complications; no myelopathy developed but three sacral neuropathies appeared following 77.12-77.4 GyRBE. Conclusions Local control with this treatment is high in patients radiated at the time of primary presentation. Spinal cord dose constraints appear to be safe. Sacral nerves receiving 77.12-77.4 GyRBE are at risk for late toxicity. PMID:19095372
Saito, M; Kikuchi, Y; Kawarai Lefor, A; Hoshina, M
2017-01-01
Background. High-dose inhaled steroid therapy has been shown to be effective in children and adults with asthma exacerbations. However, few reports are available regarding its efficacy for asthma exacerbations in younger children. Objective. In this study, we administered high-dose nebulized budesonide therapy for mild asthma exacerbations in children < 3 years of age and compared its efficacy and safety with systemic steroid therapy. Methods. This study included children < 3 years old with mild asthma exacerbations. Patients were randomly assigned to two groups: the BIS group was given 1 mg of nebulized budesonide twice daily, and the PSL group received prednisolone 0.5 mg/kg iv three times daily. Days to disappearance of wheezing, days of steroid use, days of oxygen use, serum cortisol level, and incidence of adverse events during treatment were compared between the groups. Result. Wheezing disappeared after an average of five days, and steroids were administered for an average of five days in both groups, with no significant difference in days of oxygen use. Serum cortisol levels at initiation and during the course of treatment remained unchanged in the BIS group, and were decreased in the PSL group; however, the decrease in the latter group was not pathologic. Conclusion. For children < 3 years old with mild asthma exacerbations, high-dose nebulized budesonide therapy is equally as effective as systemic steroid therapy.
Dudley, Mark E.; Wunderlich, John R.; Yang, James C.; Sherry, Richard M.; Topalian, Suzanne L.; Restifo, Nicholas P.; Royal, Richard E.; Kammula, Udai; White, Don E.; Mavroukakis, Sharon A.; Rogers, Linda J.; Gracia, Gerald J.; Jones, Stephanie A.; Mangiameli, David P.; Pelletier, Michelle M.; Gea-Banacloche, Juan; Robinson, Michael R.; Berman, David M.; Filie, Armando C.; Abati, Andrea; Rosenberg, Steven A.
2006-01-01
Purpose We investigated the combination of lymphodepleting chemotherapy followed by the adoptive transfer of autologous tumor reactive lymphocytes for the treatment of patients with refractory metastatic melanoma. Patients and Methods Thirty-five patients with metastatic melanoma, all but one with disease refractory to treatment with high-dose interleukin (IL)-2 and many with progressive disease after chemotherapy, underwent lymphodepleting conditioning with two days of cyclophosphamide (60 mg/kg) followed by five days of fludarabine (25 mg/m2). On the day following the final dose of fludarabine, all patients received cell infusion with autologous tumor-reactive, rapidly expanded tumor infiltrating lymphocyte cultures and high-dose IL-2 therapy. Results Eighteen (51%) of 35 treated patients experienced objective clinical responses including three ongoing complete responses and 15 partial responses with a mean duration of 11.5 ± 2.2 months. Sites of regression included metastases to lung, liver, lymph nodes, brain, and cutaneous and subcutaneous tissues. Toxicities of treatment included the expected hematologic toxicities of chemotherapy including neutropenia, thrombocytopenia, and lymphopenia, the transient toxicities of high-dose IL-2 therapy, two patients who developed Pneumocystis pneumonia and one patient who developed an Epstein-Barr virus-related lymphoproliferation. Conclusion Lymphodepleting chemotherapy followed by the transfer of highly avid antitumor lymphocytes can mediate significant tumor regression in heavily pretreated patients with IL-2 refractory metastatic melanoma. PMID:15800326
Accumulating Evidence for a Drug–Drug Interaction Between Methotrexate and Proton Pump Inhibitors
Mackey, Ann Corken; Kluetz, Paul; Jappar, Dilara; Korvick, Joyce
2012-01-01
Background. A number of medications are known to interact with methotrexate through various mechanisms. The aim of this article is to apprise practitioners of a new labeling change based on the accumulating evidence for a possible drug–drug interaction between methotrexate (primarily at high doses) and proton pump inhibitors (PPIs). Methods. The U.S. Food and Drug Administration (FDA) Adverse Event Reporting System (AERS) database of spontaneous adverse event reports and the published literature were searched for cases reporting an interaction between methotrexate and PPIs. Results. A search of the AERS database and existing literature found several individual case reports of drug–drug interactions and three additional supportive studies that suggest potential underlying mechanisms for the interaction. Conclusion. There is evidence to suggest that concomitant use of methotrexate (primarily at high doses) with PPIs such as omeprazole, esomeprazole, and pantoprazole may decrease methotrexate clearance, leading to elevated serum levels of methotrexate and/or its metabolite hydroxymethotrexate, possibly leading to methotrexate toxicities. In several case reports, no methotrexate toxicity was found when a histamine H2 blocker was substituted for a PPI. Based on the reviewed data, the FDA updated the methotrexate label to include the possible drug–drug interaction between high-dose methotrexate and PPIs. Physicians should be alerted to this potential drug–drug interaction in patients receiving concomitant high-dose methotrexate and PPIs. PMID:22477728
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harriss-Phillips, Wendy M., E-mail: wharrphil@gmail.com; School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia; Bezak, Eva
Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presentedmore » in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of radiation therapy requires sophisticated stochastic modeling to predict tumor cell kill. For stereotactic ablative radiation therapy, high doses in the first week followed by doses that are more moderate may be beneficial because a high percentage of hypoxic cells could be eradicated early while keeping the required BED{sub 10} relatively low and BED{sub 3} toxicity to tolerable levels.« less
Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rai, Bhavana; Patel, Firuza D., E-mail: firuzapatel@gmail.com; Chakraborty, Santam
2013-04-01
Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the secondmore » application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.« less
Mattiuzzi, Gloria N.; Cortes, Jorge E.; Blamble, Deborah A.; Bekele, B. Nebiyou; Xiao, Lianchun; Cabanillas, Maria; Borthakur, Gautam; O’Brien, Susan; Kantarjian, Hagop
2014-01-01
BACKGROUND Nausea and vomiting in patients with acute myelogenous leukemia (AML) can be from various causes, including the use of high-dose cytarabine. METHODS The authors compared 2 schedules of palonosetron versus ondansetron in the treatment of chemotherapy-induced nausea and vomiting (CINV) in patients with AML receiving high-dose cytarabine. Patients were randomized to: 1) ondansetron, 8 mg intravenously (IV), followed by 24 mg continuous infusion 30 minutes before high-dose cytarabine and until 12 hours after the high-dose cytarabine infusion ended; 2) palonosetron, 0.25 mg IV 30 minutes before chemotherapy, daily from Day 1 of high-dose cytarabine up to Day 5; or 3) palonosetron, 0.25 mg IV 30 minutes before high-dose cytarabine on Days 1, 3, and 5. RESULTS Forty-seven patients on ondansetron and 48 patients on each of the palonosetron arms were evaluable for efficacy. Patients in the palonosetron arms achieved higher complete response rates (no emetic episodes plus no rescue medication), but the difference was not statistically significant (ondansetron, 21%; palonosetron on Days 1–5, 31%; palonosetron on Days 1, 3, and 5, 35%; P = .32). Greater than 77% of patients in each arm were free of nausea on Day 1; however, on Days 2 through 5, the proportion of patients without nausea declined similarly in all 3 groups. On Days 6 and 7, significantly more patients receiving palonosetron on Days 1 to 5 were free of nausea (P = .001 and P = .0247, respectively). CONCLUSIONS The daily assessments of emesis did not show significant differences between the study arms. Patients receiving palonosetron on Days 1 to 5 had significantly less severe nausea and experienced significantly less impact of CINV on daily activities on Days 6 and 7. PMID:21218459
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massimino, Maura; Gandola, Lorenza; Spreafico, Filippo
Purpose: Supratentorial primitive neuroectodermal tumors (S-PNET) are rare and have a grim prognosis, frequently taking an aggressive course with local relapse and metastatic spread. We report the results of a mono-institutional therapeutic trial. Methods and Materials: We enrolled 15 consecutive patients to preradiation chemotherapy (CT) consisting of high-dose methotrexate, high-dose etoposide, high-dose cyclophosphamide, and high-dose carboplatin, craniospinal irradiation (CSI) with hyperfractionated accelerated radiotherapy (HART) plus focal boost, maintenance with vincristine/lomustine or consolidation with high-dose thiotepa followed by autologous stem-cell rescue. Results: Median age was 9 years; 7 were male, 8 female. Site of disease was pineal in 3, elsewhere inmore » 12. Six patients were had no evidence of disease after surgery (NED). Of those with evidence of disease after surgery (ED), 2 had central nervous system spread. Of the 9 ED patients, 2 had complete response (CR) and 2 partial response (PR) after CT, 4 stable disease, and 1 progressive disease. Of the 7 ED patients before radiotherapy, 1 had CR, 4 PR, and 2 minor response, thus obtaining a 44% CR + PR after CT and 71% after HART. Because of rapid progression in 2 of the first 5 patients, high-dose thiotepa was systematically adopted after HART in the subsequent 10 patients. Six of 15 patients relapsed (4 locally, 1 locally with dissemination, 1 with dissemination) a mean of 6 months after starting CT, 2 developed second tumors; 5 of 6 relapsers died at a median of 13 months. Three-year progression-free survival, event-free survival, and overall survival were 54%, 34%, and 61%, respectively. Conclusion: Hyperfractionated accelerated RT was the main tool in obtaining responses in S-PNET; introducing the myeloablative phase improved the prognosis (3/10 vs. 3/5 relapses), though the outcome remained unsatisfactory despite the adoption of this intensive treatment.« less
Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Mowlavi, Ali Asghar; Meigooni, Ali Soleimani
2012-01-01
Background Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. Materials and methods MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution, radial dose function and 2D anisotropy function of the source. These parameters of this source are compared with the available data for Ralstron 60Co and microSelectron192Ir sources. Besides, a superimposition method was developed to extend the obtained results for the GZP6 source No. 3 to other GZP6 sources. Results The simulated value for dose rate constant for GZP6 source was 1.104±0.03 cGyh-1U-1. The graphical and tabulated radial dose function and 2D anisotropy function of this source are presented here. The results of these investigations show that the dosimetric parameters of GZP6 source are comparable to those for the Ralstron source. While dose rate constant for the two 60Co sources are similar to that for the microSelectron192Ir source, there are differences between radial dose function and anisotropy functions. Radial dose function of the 192Ir source is less steep than both 60Co source models. In addition, the 60Co sources are showing more isotropic dose distribution than the 192Ir source. Conclusions The superimposition method is applicable to produce dose distributions for other source arrangements from the dose distribution of a single source. The calculated dosimetric quantities of this new source can be introduced as input data to the GZP6 treatment planning system (TPS) and to validate the performance of the TPS. PMID:23077455
SU-F-T-554: Dark Current Effect On CyberKnife Beam Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chang, A
Purpose: All RF linear accelerators produce dark current to varying degrees when an accelerating voltage and RF input is applied in the absence of electron gun injection. This study is to evaluate how dark current from the linear accelerator of CyberKnife affect the dose in the reference dosimetry. Methods: The G4 CyberKnife system with 6MV photon beam was used in this study. Using the ion chamber and the diode detector, the dose was measured in water with varying time delay between acquiring charges and staring beam-on after applying high-voltage into the linear accelerator. The dose was measured after the timemore » delay with over the range of 0 to 120 seconds in the accelerating high-voltage mode without beam-on, applying 0, 10, 50, 100, and 200 MUs. For the measurements, the collimator of 60 mm was used and the detectors were placed at the depths of 10 cm with the source-to-surface distance of 80 cm. Results: The dark current was constant over time regardless of MU. The dose due to the dark current increased over time linearly with the R-squared value of 0.9983 up to 4.4 cGy for the time 120 seconds. In the dose rate setting of 720 MU/min, the relative dose when applying the accelerating voltage without beam-on was increased over time up to 0.6% but it was less than the leakage radiation resulted from the accelerated head. As the reference dosimetry condition, when 100 MU was delivered after 10 seconds time delay, the relative dose increased by 0.7% but 6.7% for the low MU (10 MU). Conclusion: In the dosimetry using CyberKnife system, the constant dark current affected to the dose. Although the time delay in the accelerating high-voltage mode without beam-on is within 10 seconds, the dose less than 100 cGy can be overestimated more than 1%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi
2006-06-01
Purpose: To evaluate the incidence of Grade 2 or worse rectal bleeding after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiotherapy (EBRT), with special emphasis on the relationship between the incidence of rectal bleeding and the rectal dose from HDR brachytherapy. Methods and Materials: The records of 100 patients who were treated by HDR brachytherapy combined with EBRT for {>=}12 months were analyzed. The fractionation schema for HDR brachytherapy was prospectively changed, and the total radiation dose for EBRT was fixed at 51 Gy. The distribution of the fractionation schema used in the patients was as follows: 5 Gy xmore » 5 in 13 patients; 7 Gy x 3 in 19 patients; and 9 Gy x 2 in 68 patients. Results: Ten patients (10%) developed Grade 2 or worse rectal bleeding. Regarding the correlation with dosimetric factors, no significant differences were found in the average percentage of the entire rectal volume receiving 30%, 50%, 80%, and 90% of the prescribed radiation dose from EBRT between those with bleeding and those without. The average percentage of the entire rectal volume receiving 10%, 30%, 50%, 80%, and 90% of the prescribed radiation dose from HDR brachytherapy in those who developed rectal bleeding was 77.9%, 28.6%, 9.0%, 1.5%, and 0.3%, respectively, and was 69.2%, 22.2%, 6.6%, 0.9%, and 0.4%, respectively, in those without bleeding. The differences in the percentages of the entire rectal volume receiving 10%, 30%, and 50% between those with and without bleeding were statistically significant. Conclusions: The rectal dose from HDR brachytherapy for patients with prostate cancer may have a significant impact on the incidence of Grade 2 or worse rectal bleeding.« less
Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options
2013-01-01
Purpose Permanent low-dose-rate (LDR-BT) and temporary high-dose-rate (HDR-BT) brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never to be conducted comparing these two forms of brachytherapy, a comparative analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. The aim of this paper is to look for possible similarities and differences between both brachytherapy modalities. Indications and contraindications for monotherapy and for brachytherapy as a boost to external beam radiation therapy (EBRT) are presented. It is suggested that each of these techniques has attributes that advocates for one or the other. First, they represent the extreme ends of the spectrum with respect to dose rate and fractionation, and therefore have inherently different radiobiological properties. Low-dose-rate brachytherapy has the great advantage of being practically a one-time procedure, and enjoys a long-term follow-up database supporting its excellent outcomes and low morbidity. Low-dose-rate brachytherapy has been a gold standard for prostate brachytherapy in low risk patients since many years. On the other hand, HDR is a fairly invasive procedure requiring several sessions associated with a brief hospital stay. Although lacking in significant long-term data, it possesses the technical advantage of control over its postimplant dosimetry (by modulating the source dwell time and position), which is absent in LDR brachytherapy. This important difference in dosimetric control allows HDR doses to be escalated safely, a flexibility that does not exist for LDR brachytherapy. Conclusions Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy, using current dose regimens. At present, all available clinical data regarding these two techniques suggests that they are equally effective, stage for stage, in providing high tumor control rates. PMID:23634153
Reinisch, Walter; Altorjay, Istvan; Zsigmond, Ferenc; Primas, Christian; Vogelsang, Harald; Novacek, Gottfried; Reinisch, Sieglinde; Thomsen, Lars L.
2015-01-01
Abstract Objective. Iron isomaltoside 1000 (Monofer®) is a high-dose intravenous (IV) iron, which in a recent 8 weeks trial in inflammatory bowel disease (IBD) subjects with iron deficiency anemia (IDA) demonstrated good tolerability and efficacy. The present trial is an extension to this trial, which evaluates the need for additional high IV iron doses to maintain a stable hemoglobin (Hb) ≥12.0 g/dl. Material and methods. This was a prospective, open-label, 12 months trial of European IBD subjects willing to participate after completing the lead-in trial. Subjects were allowed re-dosing with 500–2000 mg single doses of iron isomaltoside 1000 infused over ∼15 min at 3 months intervals depending on a predefined algorithm. Outcome measures included Hb, safety parameters and need for additional iron dosing. Results. A total of 39 subjects were enrolled of which 34 subjects required re-dosing with a median cumulative 1-year dose of 1.8 g (mean cumulative dose 2.2 g). The mean (SD) Hb was 12.3 (1.5) g/dl at baseline, 12.8 (1.6) g/dl at 3 months, 12.8 (1.6) g/dl at 6 months, 12.9 (1.4) g/dl at 9 months and 12.9 (1.6) g/dl at 12 months. Seventy-four percent of subjects who had an Hb ≥12.0 g/dl at baseline were able to maintain Hb ≥12.0 g/dl till the end of the trial at 12 months. Nonserious probably related hypersensitivity reactions without significant hypotension were reported at the beginning of the infusion in two subjects, who recovered without sequelae. Conclusion. Repeated treatment of iron deficiency with iron isomaltoside 1000 could avoid episodes of IDA without major safety issues. PMID:25900645
Azimian-Zavareh, Vajihe; Hossein, Ghamartaj; Janzamin, Ehsan
2012-01-01
Objective: Glycogen synthase kinase-3β (GSK-3β) has been reported to be required for androgen receptor (AR) activity. This study sought to determine the usefulness of lithium chloride (LiCl) as a highly selective inhibitor of GSK-3β to increase the sensitivity of LNCap cells to doxorubicin (Dox), etoposide (Eto), and vinblastine (Vin) drugs. Materials and Methods: Thiazolyl Blue Tetrazolium Blue (MTT) assay was used to determine the cytotoxic effect to LiCl alone or in combination with low dose and IC50 doses of drugs. Subsequently, cell cycle analysis was performed by using flow cytometry. Results: LiCl showed cytotoxic effect in a dose- and time-dependent manner (P<0.001). Both Dox (100 or 280 nM) and Vin IC50 (5 nM) doses caused G2/M-phase arrest (P<0.001) compared with control. However, low dose (10 μM) or IC50 (70 μM) Eto doses showed G2/M or S-phase arrests, respectively (P<0.001). Combination of low dose or IC50 dose of Eto with LiCl showed increased apoptosis as revealed by high percent of cells in SubG1 (P<0.05, P<0.01, respectively). Moreover, Eto (10 μM) led to decreased percent of cells in G2/M phase when combined with LiCl (P<0.05). Conclusion: This study showed that LiCl increases apoptosis of (LNCap) Lymph Node Carcinoma of the Prostate cells in the presence of Eto, which is S- and G2-phase-specific drug. PMID:23248400
Yim, Haejun; Yang, Hyeong-Tae; Cho, Yong-Suk; Kim, Dohern; Kim, Jong-Hyun; Chun, Wook; Hur, Jun
2014-12-01
This study is a phase 1 and 2 clinical trial for investigating the safety profile, effective treatment dose and effectiveness of the newly developed thermosensitive hydrogel-type cultured epidermal allograft. For phase 1, the keratinocytes were divided into 3 groups as follows, with 5 patients in each group: (1) low-dose group (6.7×10(6)/1.5mL), (2) medium-dose group (2×10(7)/1.5mL), and (3) high-dose group (6.0×10(7)/1.5mL). The second phase of the trial proceeded with 10 cases after choosing the most effective dose based on the analysis of the first phase. When comparing re-epithelialization time, medium- and high-dose group showed significantly shorter re-epithelialization time than low-dose group (p=0.003 and p=0.002). A total of 15 cases, 5 cases selected from phase 1 and 10 cases test in phase 2 with the medium dose, were compared with the re-epithelialization period. The re-epithelialization period was 9.6±4.0 days in the test site and 12.4±4.8 days in the control site. In the test site, re-epithelialization was 2.8±1.8 days faster than in the control site (p<0.0001). There was no significant adverse reaction in our clinical trial. In conclusion, this new type of CEAllo accelerates wound healing time and shows the safety. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Nieto, Y; Thall, P; Valdez, B; Andersson, B; Popat, U; Anderlini, P; Shpall, EJ; Bassett, R; Alousi, A; Hosing, C; Kebriaei, P; Qazilbash, M; Gulbis, A; Chancoco, C; Bashir, Q; Ciurea, S; Khouri, I; Parmar, S; Shah, N; Worth, L; Rondon, G; Champlin, R; Jones, RB
2014-01-01
We developed a new high-dose combination of infusional gemcitabine with busulfan/melphalan for lymphoid tumors. Gemcitabine dose was escalated by extending infusions at a fixed rate of 10 mg/m2/min in sequential cohorts, in daily, 3-dose or 2-dose schedules. Each dose immediately preceded busulfan (adjusted targeting AUC 4,000 μM.min−1/day × 4 days) or melphalan (60 mg/m2/day × 2 days). We enrolled 133 patients (80 Hodgkin’s lymphoma (HL), 46 non-Hodgkin’s lymphoma (NHL), 7 myeloma), median 3 prior regimens; primary refractory disease in 63% HL/45% NHL and PET-positive tumors at transplant in 50% patients. Two patients died from early posttransplant infections. The major toxicity was mucositis. The daily and 3-dose schedules caused substantial cutaneous toxicity. In contrast, the 2-dose schedule was better tolerated, which allowed us to extend the infusions from 15 to 270 minutes. Pretransplant values of C-reactive protein, b-type natriuretic peptide, ferritin or haptoglobin did not correlate with toxicity. Overall response and complete response rates were 87%/62% (HL), 100%/69% (B-LCL), 66%/66% (T-NHL), and 71%/57% (myeloma). At median follow-up of 24 months (3–63), the event-free/overall survival rates are 54%/72% (HL), 60%/89% (B-LCL), 70%/70% (T-NHL) and 43%/43% (myeloma). In conclusion, gemcitabine/busulfan/melphalan is a feasible regimen with substantial activity against a range of lymphoid malignancies. This regimen merits further evaluation in phase II and III trials. PMID:22643322
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadeghi, Mahdi; Taghdiri, Fatemeh; Hamed Hosseini, S.
Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters ofmore » AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.« less
Abuse Liability and Reinforcing Efficacy of Oral Tramadol in Humans
Babalonis, Shanna; Lofwall, Michelle R.; Nuzzo, Paul A.; Siegel, Anthony J.; Walsh, Sharon L.
2012-01-01
BACKGROUND Tramadol, a monoaminergic reuptake inhibitor, is hepatically metabolized to an opioid agonist (M1). This atypical analgesic is generally considered to have limited abuse liability. Recent reports of its abuse have increased in the U.S., leading to more stringent regulation in some states, but not nationally. The purpose of this study was to examine the relative abuse liability and reinforcing efficacy of tramadol in comparison to a high (oxycodone) and low efficacy (codeine) opioid agonist. METHODS Nine healthy, non-dependent prescription opioid abusers (6 male, 3 female) participated in this within-subject, randomized, double blind, placebo-controlled study. Participants completed 14 paired sessions (7 sample, 7 self-administration). During each sample session, an oral dose of tramadol (200, 400 mg), oxycodone (20, 40 mg), codeine (100, 200 mg) or placebo was administered, and a full array of abuse liability measures was collected. During self-administration sessions, volunteers were given the opportunity to work (via progressive ratio) for the sample dose or money. RESULTS All active doses were self-administered; placebo engendered no responding. The high doses of tramadol and oxycodone were readily self-administered (70%, 59% of available drug, respectively); lower doses and both codeine doses maintained intermediate levels of drug taking. All three drugs dose-dependently increased measures indicative of abuse liability, relative to placebo; however, the magnitude and time course of these and other pharmacodynamic effects varied qualitatively across drugs. CONCLUSIONS This study demonstrates that, like other mu opioids, higher doses of tramadol function as reinforcers in opioid abusers, providing new empirical data for regulatory evaluation. PMID:23098678
Ahn, Shihyun; Kim, Byung -Jae; Lin, Yi -Hsuan; ...
2016-07-26
The effects of proton irradiation on the dc performance of InAlN/GaN metal-oxide-semiconductor high electron mobility transistors (MOSHEMTs) with Al 2O 3 as the gate oxide were investigated. The InAlN/GaN MOSHEMTs were irradiated with doses ranging from 1×10 13 to 1×10 15cm –2 at a fixed energy of 5MeV. There was minimal damage induced in the two dimensional electron gas at the lowest irradiation dose with no measurable increase in sheet resistance, whereas a 9.7% increase of the sheet resistance was observed at the highest irradiation dose. By sharp contrast, all irradiation doses created more severe degradation in the Ohmic metalmore » contacts, with increases of specific contact resistance from 54% to 114% over the range of doses investigated. These resulted in source-drain current–voltage decreases ranging from 96 to 242 mA/mm over this dose range. The trap density determined from temperature dependent drain current subthreshold swing measurements increased from 1.6 × 10 13 cm –2 V –1 for the reference MOSHEMTs to 6.7 × 10 13 cm –2 V –1 for devices irradiated with the highest dose. In conclusion, the carrier removal rate was 1287 ± 64 cm –1, higher than the authors previously observed in AlGaN/GaN MOSHEMTs for the same proton energy and consistent with the lower average bond energy of the InAlN.« less
Factors associated with mortality of myxedema coma: report of eight cases and literature survey.
Yamamoto, T; Fukuyama, J; Fujiyoshi, A
1999-12-01
High-dose thyroid hormone replacement has been recommended for treatment of myxedema coma (MC) while questions of safety of the therapy and of efficacy of low-dose thyroid hormone replacement have not been systematically addressed. We treated 8 patients with MC in a period of 18 years, the first 3 with high-dose intravenous injections of levotriiodothyronine (LT3) and the other 5 patients with a smaller amount of either LT3 or levothyroxine (LT4). Two of the first 3 patients died of pneumonia and the other 5 recovered despite pulmonary abnormalities at the outset. To find factors associated with fatal outcome after treatment, the MEDLINE database was searched for MC cases with data of thyroid hormone replacement and outcome within 1 month of therapy. Clinical data for our 5 patients and 82 cases from the MEDLINE search were pooled and factors associated with mortality were sought among age, gender, presence of cardiac or pulmonary complications, and doses of thyroid hormone by multiple logistic regression analysis. It revealed that greater age, cardiac complications, and high-dose thyroid hormone replacement (LT4 > or = 500 microg/d or LT3 > or = 75 microg/d) were significantly associated with a fatal outcome within 1 month of treatment. Elderly MC patients can be treated with low-dose hormone replacement. A bolus of 500 microg LT4, especially by mouth or via nasogastric tube, appears to be tolerated by younger patients (< 55 years) without cardiac complication. The conclusion remains to be confirmed in more patients.
Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Alice Y., E-mail: hoa1234@mskcc.org; Patel, Nisha; Ohri, Nisha
To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV)more » (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of the IMNs. Refinement of radiation techniques in reconstructed patients who require comprehensive nodal irradiation is warranted.« less
High glucose impaired estrogen receptor alpha signaling via β-catenin in osteoblastic MC3T3-E1.
Wang, Rui; Gao, Dong; Zhou, Yin; Chen, Lu; Luo, Bin; Yu, Yanrong; Li, Hao; Hu, Jiawei; Huang, Qiren; He, Ming; Peng, Weijie; Luo, Dan
2017-11-01
Diabetic Mellitus is a risk factor for osteoporosis. It has been suggested that altered estrogen or estrogen receptor α/β (ERα/β) signaling may be involved in diabetic osteoporosis. The present study is to investigate the effects of high glucose on ERα/β signaling in osteoblastic MC3T3-E1 and how the altered signaling of ERα/β affect osteoblastic bone formation. ERα/β signaling was demonstrated as ERα/β protein expression (Western Blotting) and ER transcription activity (Luciferase Reporter assays). Proliferation (WSK-1 assaying), differentiation (ALP staining) and mineralization (Alizalard Red staining) of MC3T3-E1 were examined to evaluate bone formation function. It has been found that high glucose increased ERα/β expression dose-dependently and time-dependently, but high glucose (33mM) decreased ERα transcription activity. 17β-estradiol increased the ERα/β expression dose-dependently in normal medium, but decreased the ERα/β expression dose-dependently in medium with high glucose (33mM). High glucose decreased bone formation and also decreased the osteogenic effects of 17β-estradiol (10 -8 M). High glucose decreased β-catenin expression dose-dependently and time-dependently. LiCl, an inhibitor of β-catenin degradation, decreased ERα expression but increased ERα transcription activity. When compared with high glucose treatment, LiCl (5mM) increased ALP activity and calcified nodes. Besides, high glucose also decreased the protein expression PI-3K, pAKT/AKT, GSK-3β. In conclusion, the present study suggested that high glucose may impair ERα transcription activity by inhibiting β-catenin signaling in osteoblastic MC3T3-E1, leading decreased bone formation ligand-dependently or ligand-independently. Copyright © 2017 Elsevier Ltd. All rights reserved.
Qian, Weibin; Cai, Xinrui; Zhang, Xinying; Wang, Yingying; Qian, Qiuhai; Hasegawa, Junichi
2016-01-01
Background Daisaikoto (DSKT), a classical traditional Chinese herbal formula, has been used for treating digestive diseases for 1800 years in China. Therefore, in this study, we are going to investigate the effect of DSKT on diabetic fatty liver rats induced by a high-fat diet and streptozotocin (STZ), and the effects of DSKT on silent mating type information regulation 2 homolog 1 (SIRT1) and nuclear factor kappa B (NF-kappaB). Methods Diabetic fatty liver rat model was selected to establish a high-fat diet and STZ. Sixty Wistar rats were divided into six groups (n = 10): control group, high-fat diet + STZ group, simvastatin treatment group, DSKT low dose, medial dose and high dose treatment groups. After 8 weeks of drug intervention, body and liver weights, blood chemistry, blood glucose and insulin were examined. The expressions of sirtuin 1 and NF-kappaB in the liver were observed by RT-PCR and immunohistochemistry, respectively. Results A high-fat diet increased body, liver weights, and serum cholesterol concentrations. Intraperitoneal injection of STZ increased blood glucose and decreased body weights. DSKT improved them. Homeostasis model assessment-estimated insulin resistance (HOMA-IR) indices were increased in the high-fat diet groups. DSKT improved them too. In histological examinations of the liver, we observed a significant improvement after treatment. Immunostaining expression of NF-kappaB in the liver was improved by DSKT and simvastatin. The mRNA expressions of SIRT1 in the liver were increased by DSKT and simvastatin. Conclusion We have demonstrated that DSKT is capable of reversing dyslipidemia and insulin resistance induced by a high-fat diet and STZ. High dose DSKT reveals a stronger effect than simvastatin on the expressions of SIRT1 and NF-kappaB. Furthermore, DSKT has shown a strong dose-depended protective effect on diabetic fatty liver. PMID:27493486
Aglipay, Mary; Birken, Catherine S.; Parkin, Patricia C.; Loeb, Mark B.; Thorpe, Kevin; Chen, Yang; Laupacis, Andreas; Mamdani, Muhammad; Macarthur, Colin; Hoch, Jeffrey S.; Mazzulli, Tony
2017-01-01
Importance Epidemiological studies support a link between low 25-hydroxyvitamin D levels and a higher risk of viral upper respiratory tract infections. However, whether winter supplementation of vitamin D reduces the risk among children is unknown. Objective To determine whether high-dose vs standard-dose vitamin D supplementation reduces the incidence of wintertime upper respiratory tract infections in young children. Design, Setting, and Participants A randomized clinical trial was conducted during the winter months between September 13, 2011, and June 30, 2015, among children aged 1 through 5 years enrolled in TARGet Kids!, a multisite primary care practice–based research network in Toronto, Ontario, Canada. Interventions Three hundred forty-nine participants were randomized to receive 2000 IU/d of vitamin D oral supplementation (high-dose group) vs 354 participants who were randomized to receive 400 IU/d (standard-dose group) for a minimum of 4 months between September and May. Main Outcome Measures The primary outcome was the number of laboratory-confirmed viral upper respiratory tract infections based on parent-collected nasal swabs over the winter months. Secondary outcomes included the number of influenza infections, noninfluenza infections, parent-reported upper respiratory tract illnesses, time to first upper respiratory tract infection, and serum 25-hydroxyvitamin D levels at study termination. Results Among 703 participants who were randomized (mean age, 2.7 years, 57.7% boys), 699 (99.4%) completed the trial. The mean number of laboratory-confirmed upper respiratory tract infections per child was 1.05 (95% CI, 0.91-1.19) for the high-dose group and 1.03 (95% CI, 0.90-1.16) for the standard-dose group, for a between-group difference of 0.02 (95% CI, −0.17 to 0.21) per child. There was no statistically significant difference in number of laboratory-confirmed infections between groups (incidence rate ratio [RR], 0.97; 95% CI, 0.80-1.16). There was also no significant difference in the median time to the first laboratory-confirmed infection: 3.95 months (95% CI, 3.02-5.95 months) for the high-dose group vs 3.29 months (95% CI, 2.66-4.14 months) for the standard-dose group, or number of parent-reported upper respiratory tract illnesses between groups (625 for high-dose vs 600 for standard-dose groups, incidence RR, 1.01; 95% CI, 0.88-1.16). At study termination, serum 25-hydroxyvitamin D levels were 48.7 ng/mL (95% CI, 46.9-50.5 ng/mL) in the high-dose group and 36.8 ng/mL (95% CI, 35.4-38.2 ng/mL) in the standard-dose group. Conclusions and Relevance Among healthy children aged 1 to 5 years, daily administration of 2000 IU compared with 400 IU of vitamin D supplementation did not reduce overall wintertime upper respiratory tract infections. These findings do not support the routine use of high-dose vitamin D supplementation in children for the prevention of viral upper respiratory tract infections. Trial Registration clinicaltrials.gov Identifier: NCT01419262 PMID:28719693
HDR {sup 192}Ir source speed measurements using a high speed video camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio
Purpose: The dose delivered with a HDR {sup 192}Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a {sup 192}Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulatingmore » the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Streitparth, Florian; Pech, Maciej; Boehmig, Michael
2006-08-01
Purpose: The aim of this study was to assess the tolerance dose of gastric mucosa for single-fraction computed tomography (CT)-guided, high-dose-rate (HDR) brachytherapy of liver malignancies. Methods and Materials: A total of 33 patients treated by CT-guided HDR brachytherapy of liver malignancies in segments II and/or III were included. Dose planning was performed upon a three-dimensional CT data set acquired after percutaneous applicator positioning. All patients received gastric protection post-treatment. For further analysis, the contours of the gastric wall were defined in every CT slice using Brachyvision Software. Dose-volume histograms were calculated for each treatment and correlated with clinical datamore » derived from questionnaires assessing Common Toxicity Criteria (CTC). All patients presenting symptoms of upper GI toxicity were examined endoscopically. Results: Summarizing all patients the minimum dose applied to 1 ml of the gastric wall (D{sub 1ml}) ranged from 6.3 to 34.2 Gy; median, 14.3 Gy. Toxicity was present in 18 patients (55%). We found nausea in 16 (69%), emesis in 9 (27%), cramping in 13 (39%), weight loss in 12 (36%), gastritis in 4 (12%), and ulceration in 5 patients (15%). We found a threshold dose D{sub 1ml} of 11 Gy for general gastric toxicity and 15.5 Gy for gastric ulceration verified by an univariate analysis (p = 0.01). Conclusions: For a single fraction, small volume irradiation we found in the upper abdomen a threshold dose D{sub 1ml} of 15.5 Gy for the clinical endpoint ulceration of the gastric mucosa. This in vivo assessment is in accordance with previously published tolerance data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghadjar, Pirus; Zelefsky, Michael J.; Spratt, Daniel E.
2014-02-01
Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analysesmore » were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the bladder trigone seems to be associated with a reduction in late GU toxicity.« less
WE-D-BRA-05: Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ger, R; Craft, DF; Burgett, EA
Purpose: To test the feasibility of using 3D-printed patient-specific phantoms for intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We created a patient-specific whole-head phantom using a 3D printer. The printer data file was created from high-resolution DICOM computed tomography (CT) images of 3-year old child treated at our institution for medulloblastoma. A custom-modified extruder system was used to create tissue-equivalent materials. For the printing process, the Hounsfield Units from the CT images were converted to proportional volumetric densities. A 5-field IMRT plan was created from the patient CT and delivered to the 3D- phantom. Dose was measured by anmore » ion chamber placed through the eye. The ion chamber was placed at the posterior edge of the planning target volume in a high dose gradient region. CT scans of the patient and 3D-phantom were fused by using commercial treatment planning software (TPS). The patient’s plan was calculated on the phantom CT images. The ion chamber’s active volume was delineated in the TPS; dose per field and total dose were obtained. Measured and calculated doses were compared. Results: The 3D-phantom dimensions and tissue densities were in good agreement with the patient. However, because of a printing error, there was a large discrepancy in the density in the frontal cortex. The calculated and measured treatment plan doses were 1.74 Gy and 1.72 Gy, respectively. For individual fields, the absolute dose difference between measured and calculated values was on average 3.50%. Conclusion: This study demonstrated the feasibility of using 3D-printed patient-specific phantoms for IMRT QA. Such phantoms would be particularly advantageous for complex IMRT treatment plans featuring high dose gradients and/or for anatomical sites with high variation in tissue densities. Our preliminary findings are promising. We anticipate that, once the printing process is further refined, the agreement between measured and calculated doses will improve.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yirmibeşoğlu Erkal, Eda, E-mail: eyirmibesoglu@yahoo.com; Karabey, Sinan; Karabey, Ayşegül
2015-07-15
Purpose: The aim of this study was to evaluate the impact of variations in pelvic dimensions on the dose delivered to the target volumes and the organs at risk (OARs) in patients with high-risk prostate cancer (PCa) to be treated with whole pelvic radiation therapy (WPRT) in an attempt to define the hostile pelvis in terms of intensity modulated radiation therapy (IMRT). Methods and Materials: In 45 men with high-risk PCa to be treated with WPRT, the target volumes and the OARs were delineated, the dose constraints for the OARs were defined, and treatment plans were generated according to themore » Radiation Therapy Oncology Group 0924 protocol. Six dimensions to reflect the depth, width, and height of the bony pelvis were measured, and 2 indexes were calculated from the planning computed tomographic scans. The minimum dose (D{sub min}), maximum dose (D{sub max}), and mean dose (D{sub mean}) for the target volumes and OARs and the partial volumes of each of these structures receiving a specified dose (V{sub D}) were calculated from the dose-volume histograms (DVHs). The data from the DVHs were correlated with the pelvic dimensions and indexes. Results: According to an overall hostility score (OHS) calculation, 25 patients were grouped as having a hospitable pelvis and 20 as having a hostile pelvis. Regarding the OHS grouping, the DVHs for the bladder, bowel bag, left femoral head, and right femoral head differed in favor of the hospitable pelvis group, and the DVHs for the rectum differed for a range of lower doses in favor of the hospitable pelvis group. Conclusions: Pelvimetry might be used as a guide to define the challenging anatomy or the hostile pelvis in terms of treatment planning for IMRT in patients with high-risk PCa to be treated with WPRT.« less
Uysal, Erdal
2017-01-01
Purpose Postoperative intraperitoneal adhesions (PIAs) are one of the most important problems surgeons have to face after laparotomies. In this study, we aimed to evaluate the effectiveness of local application of botulinum toxin type A (BoNT-A) in various dosages on the prevention of intra-abdominal adhesions in rats with experimental intra-abdominal adhesions. Methods Forty Wistar Albino female rats were randomly separated into 4 groups. The 4 groups were determined as follows: Control (group 1, n = 10); Sham (group 2, n = 10); 10-µg/kg low-dose BoNT-A (group 3, n = 10) and 30-µg/kg high-dose BoNT-A (group 4, n = 10). Subserosal injuries were created on the caecum of all rats. Laparotomy was performed on the fifth day. Adhesion scores, histopathological examination, and E-cadherin expression levels were evaluated. Results General adhesion scores for groups 1 and 2 were determined to be significantly high when compared to group 4 (P < 0.001). A significant difference was also determined between groups 3 and 4 in terms of general adhesion scores (P < 0.05). In pair comparisons, a significant decrease in high-dose BoNT-A group (group 4) when compared to groups 1 and 2 in terms of neovascularization, fibroblast density, collagen deposition and inflammatory cell count was determined (P < 0.05). Conclusion A significant decrease was observed only in postoperative PIAs in the high-dose BoNT-A group between all 4 rat-groups with experimentally created postoperative PIAs. In this study, high-dose BoNT-A is determined to be an effective agent in preventing postoperative PIAs. PMID:28706891
Sinakos, Emmanouil; Marschall, Hanns-Ulrich; Kowdley, Kris V.; Befeler, Alex; Keach, Jill; Lindor, Keith
2010-01-01
High-dose (28-30mg/kg/day) ursodeoxycholic acid (UDCA) treatment improves serum liver tests in patients with primary sclerosing cholangitis (PSC) but does not improve survival and is associated with increased rates of serious adverse events. The mechanism for the latter undesired effect remains unclear. High-dose UDCA could result in the production of hepatotoxic bile acids, such as lithocholic acid (LCA), due to limited small bowel absorption of UDCA and conversion of UDCA by bacteria in the colon. We determined the serum bile acid composition in 56 patients with PSC previously enrolled in a randomized, double-blind controlled trial of high dose UDCA versus placebo. Samples for analysis were obtained at baseline and at the end of treatment. The mean changes in UDCA (16.86 vs 0.05 μmol/L) and total bile acid (17.21 vs −0.55 μmol/L) levels were significantly higher in the UDCA group (n=29) compared to placebo (n=27) when pretreatment levels were compared (p<0.0001). LCA was also markedly increased (0.22 vs 0.01 μmol/L) in the UDCA group compared to placebo (p=0.001). No significant changes were detected for cholic acid (CA), deoxycholic acid (DCA) and chenodeoxycholic acid (CDCA). Patients (n=9) in the UDCA group who reached clinical endpoints of disease progression (development of cirrhosis, varices, liver transplantation or death) tend to have greater increase in their post-treatment total bile acid levels (34.99 vs 9.21 μmol/L) (p<0.08) compared to those who did not. Conclusion High-dose UDCA treatment in PSC patients results in marked UDCA enrichment and significant expansion of the total serum bile acid pool including lithocholic acid. PMID:20564380
Akiyama, Hiroki; Takase, Hiroshi; Kubo, Fumito; Miki, Tohru; Yamamoto, Masahide; Tomita, Makoto; Mochizuki, Manabu; Miura, Osamu; Arai, Ayako
2016-10-01
In order to prevent central nervous system (CNS) involvement and improve the prognosis of primary intraocular lymphoma (PIOL), we prospectively evaluated the efficacy of combined therapy using intravitreal methotrexate (MTX) and systemic high-dose MTX on treatment-naïve PIOL. Patients with newly diagnosed PIOL whose lymphoma was limited to the eyes were enrolled. The patients were treated with weekly intravitreal MTX until the ocular lesions were resolved, followed by five cycles of systemic high-dose MTX (3.5 g/m 2 ) every other week. Ten patients were enrolled in this study and completed the treatment. All patients achieved complete response for their ocular lesions with rapid decrease of intravitreal interleukin-10 concentration. Adverse events of intravitreal and systemic high-dose MTX were mild and tolerable. With a median follow-up of 29.5 months, four patients (40%) experienced the CNS disease development and the mean CNS lymphoma-free survival (CLFS) time was 51.1 months. Two-year CLFS, which was the primary end-point of the study, was 58.3% (95% confidence interval, 23.0-82.1%). In contrast, eight patients were treated with intravitreal MTX alone in our institute, and their 2-year CLFS was 37.5% (95% confidence interval, 8.7-67.4%). In conclusion, systemic high-dose MTX following intravitreal MTX is feasible and might be effective in preventing CNS involvement of PIOL. Further arrangements are worth considering in order to improve the effects. This study was registered with UMIN Clinical Trials Registry (UMIN000003921). © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.
Bhandari, Sunil
2011-01-01
Background The clinical need to be able to administer high doses of intravenous iron conveniently as a rapid infusion has been addressed by the recent introduction of ferric carboxymaltose and subsequently iron isomaltoside 1000. Neither requires a test dose. The maximum dose of ferric carboxymaltose is 1000 mg. The maximum dose of iron isomaltoside 1000 is based on 20 mg/kg body weight without a specified ceiling dose, thereby increasing the scope of being able to achieve total iron repletion with a single infusion. This ability to give high doses of iron is important in the context of managing iron deficiency anemia, which is associated with a number of clinical conditions where demands for iron are high. It is also an important component of the strategy as an alternative to blood transfusion. Affordability is a key issue for health services. Recent price changes affecting iron sucrose and ferric carboxymaltose, plus modifications to the manufacturers’ prescribing information, have provoked this update. Methods This study is a comparative analysis of the costs of acquiring and administering the newly available intravenous iron formulations against standard treatments in the hospital setting. The costs include the medication, nursing costs, equipment, and patient transportation. Three dosage levels (600 mg, 1000 mg, and 1600 mg) are considered. Results and conclusion The traditional standard treatments, blood and iron sucrose, cost more than the alternative intravenous iron preparations across the dose spectrum and sensitivities. Low molecular weight iron dextran is the least expensive option at the 1600 mg dose level but has the caveat of a prolonged administration time and requirement for a test dose. At 600 mg and 1000 mg dose levels, both iron isomaltoside 1000 and ferric carboxymaltose are more economical than low molecular weight iron dextran. Iron isomaltoside 1000 is less expensive than ferric carboxymaltose at all dose levels. Newly available iron preparations appear to be clinically promising, cost effective, and practical alternatives to current standards of iron repletion. PMID:22241947
Schwartz, Jill L.; Rountree, Wes; Kashuba, Angela D. M.; Brache, Vivian; Creinin, Mitchell D.; Poindexter, Alfred; Kearney, Brian P.
2011-01-01
Background Tenofovir (TFV) gel is being evaluated as a microbicide with pericoital and daily regimens. To inhibit viral replication locally, an adequate concentration in the genital tract is critical. Methods and Findings Forty-nine participants entered a two-phase study: single-dose (SD) and multi-dose (MD), were randomized to collection of genital tract samples (endocervical cells [ECC], cervicovaginal aspirate and vaginal biopsies) at one of seven time points [0.5, 1, 2, 4, 6, 8, or 24 hr(s)] post-dose following SD exposure of 4 mL 1% TFV gel and received a single dose. Forty-seven were randomized to once (QD) or twice daily (BID) dosing for 2 weeks and to collection of genital tract samples at 4, 8 or 24 hrs after the final dose, but two discontinued prior to gel application. Blood was collected during both phases at the seven times post-dose. TFV exposure was low in blood plasma for SD and MD; median Cmax was 4.0 and 3.4 ng/mL, respectively (C≤29 ng/mL). TFV concentrations were high in aspirates and tissue after SD and MD, ranging from 1.2×104 to 9.9×106 ng/mL and 2.1×102 to 1.4×106 ng/mL, respectively, and did not noticeably differ between proximal and distal tissue. TFV diphosphate (TFV-DP), the intracellular active metabolite, was high in ECC, ranging from 7.1×103 to 8.8×106 ng/mL. TFV-DP was detectable in approximately 40% of the tissue samples, ranging from 1.8×102 to 3.5×104 ng/mL. AUC for tissue TFV-DP was two logs higher after MD compared to SD, with no noticeable differences when comparing QD and BID. Conclusions Single-dose and multiple-dose TFV gel exposure resulted in high genital tract concentrations for at least 24 hours post-dose with minimal systemic absorption. These results support further study of TFV gel for HIV prevention. Trial registration ClinicalTrials.gov NCT00561496 PMID:22039430
SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campos, L T; Almeida, C E V de
Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, whichmore » is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassan Rezaeian, N; Chi, Y; Zhou, Y
2016-06-15
Purpose: We are conducting a clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer. Doses to three targets, prostate, intra-prostatic lesion, and pelvic lymph node (PLN) region, are escalated to three different levels via simultaneous integrated boost technique. Inter-/intra-fractional organ motions deteriorate planned dose distribution. This study aims at developing a dose reconstruction system to comprehensively understand the impacts of organ motion in our clinical trial. Methods: A 4D dose reconstruction system has been developed for this study. Using a GPU-based Monte-Carlo dose engine and delivery log file, the system is able to reconstruct dose on staticmore » or dynamic anatomy. For prostate and intra-prostatic targets, intra-fractional motion is the main concern. Motion trajectory acquired from Calypso in previously treated SBRT patients were used to perform 4D dose reconstructions. For pelvic target, inter-fractional motion is one concern. Eight patients, each with four cone beam CTs, were used to derive fractional motion. The delivered dose was reconstructed on the deformed anatomy. Dosimetric parameters for delivered dose distributions of the three targets were extracted and compared with planned levels. Results: For prostate intra-fractional motion, the mean 3D motion amplitude during beam delivery ranged from 1.5mm to 5.0mm and the average among all patients was 2.61mm. Inter-fractional motion for the PLN target was more significant. The average amplitude among patients was 4mm with the largest amplitude up to 9.6mm. The D95% deviation from planned level for prostate PTVs and GTVs are on average less than<0.1% and this deviation for intra-prostatic lesion PTVs and GTVs were more prominent. The dose at PLN was significantly affected with D{sub 95}% reduced by up to 44%. Conclusion: Intra-/inter-fractional organ motion is a concern for high-risk prostate SBRT, particularly for the PLN target. Our dose reconstruction approach can also serve as the basis to guide treatment adaptation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polsdofer, E; Crilly, R
Purpose: This study investigates the effect of eye size and eccentricity on doses to critical tissues by simulating doses in the Plaque Simulator (v. 6.3.1) software. Present OHSU plaque brachytherapy treatment focuses on delivering radiation to the tumor measured with ocular ultrasound plus a small margin and assumes the orbit has the dimensions of a “standard eye.” Accurately modeling the dimensions of the orbit requires a high resolution ocular CT. This study quantifies how standard differences in equatorial diameters and eccentricity affect calculated doses to critical structures in order to query the justification of the additional CT scan to themore » treatment planning process. Methods: Tumors of 10 mm × 10 mm × 5 mm were modeled at the 12:00:00 hour with a latitude of 45 degrees. Right eyes were modeled at a number of equatorial diameters from 17.5 to 28 mm for each of the standard non-notched COMS plaques with silastic inserts. The COMS plaques were fully loaded with uniform activity, centered on the tumor, and prescribed to a common tumor dose (85 Gy/100 hours). Variations in the calculated doses to normal structures were examined to see if the changes were significant. Results: The calculated dose to normal structures show a marked dependence on eye geometry. This is exemplified by fovea dose which more than doubled in the smaller eyes and nearly halved in the larger model. Additional significant dependence was found in plaque size on the calculated dose in spite of all plaques giving the same dose to the prescription point. Conclusion: The variation in dose with eye dimension fully justifies the addition of a high resolution ocular CT to the planning technique. Additional attention must be made to plaque size beyond simply covering the tumor when considering normal tissue dose.« less
SU-F-T-328: Real-Time in Vivo Dosimetry of Prostate SBRT Boost Treatments Using MOSkin Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Legge, K; O’Connor, D J; Cutajar, D
Purpose: To provide in vivo measurements of dose to the anterior rectal wall during prostate SBRT boost treatments using MOSFET detectors. Methods: Dual MOSkin detectors were attached to a Rectafix rectal sparing device and inserted into patients during SBRT boost treatments. Patients received two boost fractions, each of 9.5–10 Gy and delivered using 2 VMAT arcs. Measurements were acquired for 12 patients. MOSFET voltages were read out at 1 Hz during delivery and converted to dose. MV images were acquired at known frequency during treatment so that the position of the gantry at each point in time was known. Themore » cumulative dose at the MOSFET location was extracted from the treatment planning system at in 5.2° increments (FF beams) or at 5 points during each delivered arc (FFF beams). The MOSFET dose and planning system dose throughout the entirety of each arc were then compared using root mean square error normalised to the final planned dose for each arc. Results: The average difference between MOSFET measured and planning system doses determined over the entire course of treatment was 9.7% with a standard deviation of 3.6%. MOSFETs measured below the planned dose in 66% of arcs measured. Uncertainty in the position of the MOSFET detector and verification point are major sources of discrepancy, as the detector is placed in a high dose gradient region during treatment. Conclusion: MOSkin detectors were able to provide real time in vivo measurements of anterior rectal wall dose during prostate SBRT boost treatments. This method could be used to verify Rectafix positioning and treatment delivery. Further developments could enable this method to be used during high dose treatments to monitor dose to the rectal wall to ensure it remains at safe levels. Funding has been provided by the University of Newcastle. Kimberley Legge is the recipient of an Australian Postgraduate Award.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganesan, B; Prakasarao, A; Singaravelu, G
Purpose: The use of mega voltage gamma and x-ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin. Methods: To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap.more » To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGy Results: the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual-bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams. Conclusion: From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build-up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.« less
SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, I; Andersen, A; Coutinho, L
2015-06-15
Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factormore » (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose.« less
NASA Astrophysics Data System (ADS)
Kim, Dong Wook; Bae, Sunhyun; Chung, Weon Kuu; Lee, Yoonhee
2014-04-01
Cone-beam computed tomography (CBCT) images are currently used for patient positioning and adaptive dose calculation; however, the degree of CBCT uncertainty in cases of respiratory motion remains an interesting issue. This study evaluated the uncertainty of CBCT-based dose calculations for a moving target. Using a phantom, we estimated differences in the geometries and the Hounsfield units (HU) between CT and CBCT. The calculated dose distributions based on CT and CBCT images were also compared using a radiation treatment planning system, and the comparison included cases with respiratory motion. The geometrical uncertainties of the CT and the CBCT images were less than 0.15 cm. The HU differences between CT and CBCT images for standard-dose-head, high-quality-head, normal-pelvis, and low-dose-thorax modes were 31, 36, 23, and 33 HU, respectively. The gamma (3%, 0.3 cm)-dose distribution between CT and CBCT was greater than 1 in 99% of the area. The gamma-dose distribution between CT and CBCT during respiratory motion was also greater than 1 in 99% of the area. The uncertainty of the CBCT-based dose calculation was evaluated for cases with respiratory motion. In conclusion, image distortion due to motion did not significantly influence dosimetric parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jing; Guan, Huaiqun; Solberg, Timothy
2011-07-15
Purpose: A statistical projection restoration algorithm based on the penalized weighted least-squares (PWLS) criterion can substantially improve the image quality of low-dose CBCT images. The performance of PWLS is largely dependent on the choice of the penalty parameter. Previously, the penalty parameter was chosen empirically by trial and error. In this work, the authors developed an inverse technique to calculate the penalty parameter in PWLS for noise suppression of low-dose CBCT in image guided radiotherapy (IGRT). Methods: In IGRT, a daily CBCT is acquired for the same patient during a treatment course. In this work, the authors acquired the CBCTmore » with a high-mAs protocol for the first session and then a lower mAs protocol for the subsequent sessions. The high-mAs projections served as the goal (ideal) toward, which the low-mAs projections were to be smoothed by minimizing the PWLS objective function. The penalty parameter was determined through an inverse calculation of the derivative of the objective function incorporating both the high and low-mAs projections. Then the parameter obtained can be used for PWLS to smooth the noise in low-dose projections. CBCT projections for a CatPhan 600 and an anthropomorphic head phantom, as well as for a brain patient, were used to evaluate the performance of the proposed technique. Results: The penalty parameter in PWLS was obtained for each CBCT projection using the proposed strategy. The noise in the low-dose CBCT images reconstructed from the smoothed projections was greatly suppressed. Image quality in PWLS-processed low-dose CBCT was comparable to its corresponding high-dose CBCT. Conclusions: A technique was proposed to estimate the penalty parameter for PWLS algorithm. It provides an objective and efficient way to obtain the penalty parameter for image restoration algorithms that require predefined smoothing parameters.« less
Davison, Kade; Howe, Peter R C
2015-11-18
The metabolic syndrome is a pathological state whereby cardiovascular and metabolic dysfunction coexist and typically progress in a mutual feed-forward manner to further dysfunction and ultimately disease. The health and function of the vascular endothelium is integral in this phenomenon and thus represents a logical target for intervention. Consumption of foods high in cocoa flavanols has demonstrated a capacity to markedly improve endothelial function and key markers of the metabolic syndrome including blood pressure and insulin sensitivity. The typically high energy content of foods containing sufficient doses of cocoa flavanols has caused some reservations around its therapeutic use, but this is dependent upon the particulars of the food matrix used. Further to this, the food matrix appears to influence the dose response curve of cocoa flavanols, particularly on blood pressure, with dark chocolate appearing to be 8 times more effective in systolic blood pressure reduction than a cocoa powder drink for the equivalent dose of flavanol. Cocoa flavanol consumption conclusively demonstrates a positive impact on cardiometabolic function; however, more research is needed to understand how best to consume it to maximize the benefit while avoiding excessive fat and sugar consumption.
NASA Technical Reports Server (NTRS)
Shuryak, Igor; Sachs, Rainer K.; Hlatky, Lynn; Mark P. Little; Hahnfeldt, Philip; Brenner, David J.
2006-01-01
Because many cancer patients are diagnosed earlier and live longer than in the past, second cancers induced by radiation therapy have become a clinically significant issue. An earlier biologically based model that was designed to estimate risks of high-dose radiation induced solid cancers included initiation of stem cells to a premalignant state, inactivation of stem cells at high radiation doses, and proliferation of stem cells during cellular repopulation after inactivation. This earlier model predicted the risks of solid tumors induced by radiation therapy but overestimated the corresponding leukemia risks. Methods: To extend the model to radiation-induced leukemias, we analyzed in addition to cellular initiation, inactivation, and proliferation a repopulation mechanism specific to the hematopoietic system: long-range migration through the blood stream of hematopoietic stem cells (HSCs) from distant locations. Parameters for the model were derived from HSC biologic data in the literature and from leukemia risks among atomic bomb survivors v^ ho were subjected to much lower radiation doses. Results: Proliferating HSCs that migrate from sites distant from the high-dose region include few preleukemic HSCs, thus decreasing the high-dose leukemia risk. The extended model for leukemia provides risk estimates that are consistent with epidemiologic data for leukemia risk associated with radiation therapy over a wide dose range. For example, when applied to an earlier case-control study of 110000 women undergoing radiotherapy for uterine cancer, the model predicted an excess relative risk (ERR) of 1.9 for leukemia among women who received a large inhomogeneous fractionated external beam dose to the bone marrow (mean = 14.9 Gy), consistent with the measured ERR (2.0, 95% confidence interval [CI] = 0.2 to 6.4; from 3.6 cases expected and 11 cases observed). As a corresponding example for brachytherapy, the predicted ERR of 0.80 among women who received an inhomogeneous low-dose-rate dose to the bone marrow (mean = 2.5 Gy) was consistent with the measured ERR (0.62, 95% Cl =-0.2 to 1.9). Conclusions: An extended, biologically based model for leukemia that includes HSC initiation, inactivation, proliferation, and, uniquely for leukemia, long-range HSC migration predicts, %Kith reasonable accuracy, risks for radiationinduced leukemia associated with exposure to therapeutic doses of radiation.
Dose gradient curve: A new tool for evaluating dose gradient
Choi, Young Eun
2018-01-01
Purpose Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. Methods The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Results Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. Conclusions The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice. PMID:29698471
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Xiaomei, F; Bai, W
2015-06-15
Purpose: To compare and evaluate the performance of two different multileaf collimators(MLCi2 and Agility) delivery with volumetric modulated arc therapy techniques. Methods: Treatment plans were graded four (Low, Moderate, Moderate-High and High complexity) accorrding to the complexity. This includes 1 Low complexity(brain metastasis), 2 Moderate complexity(Lung and Liver), 1 Moderate-High complexity(prostate) and 1 High complexity ( head and neck) cases. Total dose of 60 Gy was given for all the plans. All cases were desigined two VMAT plans, one with MLCi2(group A) and the other with Agility(group B). All plans were done on Elekta VMAT with Monaco treatment planning system.more » All plans were generated with 6 MV X-rays for both Plan A and Plan B. Plans were evaluated based on the ability to meet the dose volume histogram, radiation conformity index, estimated radiation delivery time, dose homogeneity index(HI) and monitor units(MU) needed to deliver the prescribed dose. Results: Plans of group B achieved the best HI (HI = 1.05 Vs. 1.06) at the Low complexity cases while plans of group A were slightly better at the high complexity cases (HI = 1.12 Vs. 1.14). Faster VMAT plan delivery with Agility than with MLCi2 as plan complexity increased (Low complexity:52s Vs.52s, Moderate complexity:58s Vs. 55s, Moderate-High complexity: 171s Vs.152s, High complexity : 326s Vs. 202s ), especially for the most complex paradigms delivered time can be decresed 38%. No Significant changes were observed between the group B and group A plans in terms of the healthy tissue mean dose and MU. Both plans respected the planning objective for all organs at risk. Conclusion: The study concludes that VMAT plans with the novel Agility MLC can significant decrease the delivering time at the high complexity cases, while a slight compromise in the dose homogeneity index should be noted. This work was supported by The Medical Science Foundation of The health department of Hebei Province (No. 20130253)« less
Hamza, Reham Z; Al-Harbi, Mohammad S
2014-01-01
Monosodium glutamate (MSG) has been recognized as flavor enhancer that adversely affects male reproductive systems. The present study was carried out to evaluate the potential protective role of vitamin E (vit E) or selenium against MSG induced oxidative stress and histopathological changes in testis tissues of rats. Mature male Wistar rats weighing 150-200 g BW were allocated to evenly twelve groups each group of ten animals, the first group was maintained as control group, the 2nd, 3rd and 4th groups were administered MSG in three different dose levels (low, medium and high) (6, 17.5 and 60 mg/kg BW), the 5th and 6th groups were given vit E in two doses (low and high) (150 and 200 mg/kg), the 7th and 8th groups were administered selenium in two doses (low and high) (0.25 and 1 mg/kg) daily via gavage for a period of 30 days. Meanwhile the 9th and 10th groups were given combinations of MSG (high dose) and vit E while, the 11th and 12th groups were given MSG (high dose) plus selenium in two recommended doses for each one. Monosodium glutamate caused an elevation in lipid peroxidation level parallel with significant decline in SOD, CAT as well as GPx activities in testis tissues. Administration of vit E or selenium to MSG-treated groups declined lipid peroxidation, increased SOD, CAT, GPx activities. Selenium or vit E significantly reduced MSG induced histopathological changes by the entire restoration of the histological structures and the testicular antioxidant status to great extent in treated rats. In conclusion, supplementation of selenium or vit E could ameliorate the MSG induced testicular toxicity to great extent and reduce the oxidative stress on testis tissues.
2012-01-01
Background Shivering and fever are common side effects of misoprostol. An unexpectedly high rate of fever above 40°C was documented among Ecuadorian women given treatment with 800mcg of sublingual misoprostol to manage postpartum hemorrhage (PPH) (36%). Much lower rates have been reported elsewhere (0-9%). Methods From February to July 2010, an open-label pilot study was conducted in Quito, Ecuador to determine whether a lower dose--600mcg sublingual misoprostol--would result in a lower incidence of high fever (≥40°C). Rates of shivering and fever with 600mcg sublingual regimen were compared to previously documented rates in Ecuador following PPH treatment with 800mcg sublingual misoprostol. Results The 600mcg dose resulted in a 55% lower rate of high fever compared with the 800mcg regimen (8/50; 16% vs. 58/163; 36%; relative risk 0.45 95% CI 0.23-0.88). Only one woman had severe shivering following the 600mcg dose compared with 19 women in the 800mcg cohort (2% vs. 12%; relative risk 0.17 (0.02-1.25)). No cases of delirium/altered sensorium were reported with the 600mcg dose and women’s assessment of severity/tolerability of shivering and fever was better with the lower dose. Conclusions 600mcg sublingual misoprostol was found to decrease the occurrence of high fever among Ecuadorian women when given to treat PPH. This study however was not powered to examine the efficacy of this treatment regimen and cannot be recommended at this time. Future research is needed to confirm whether other populations, outside of Quito, Ecuador, experience unusually high rates of elevated body temperature following sublingual administration of misoprostol for treatment of PPH. If indeed similar trends are found elsewhere, larger trials to confirm the efficacy of lower dosages may be justified. Trial Registration Clinical trials.gov, Registry No. NCT01080846 PMID:22769055
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morton, Gerard C., E-mail: gerard.morton@sunnybrook.ca; Loblaw, D. Andrew; Chung, Hans
Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domainmore » score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose to 10% of the urethra cutpoint for urinary health-related quality of life was 120% of the prescription dose. Conclusion: EPIC was a more sensitive tool for detecting the effects on function and bother than were the generic toxicity scales. The urethral dose had the strongest association with a deteriorating urinary quality of life.« less
Shen, Zhisen; Deng, Hongxia; Ye, Dong; Zhang, Jian; Qiu, Shijie; Li, Qun; Cui, Xiang
2016-05-25
Objective: To investigate the effect of silencing DJ-1 on xenografted human laryngeal squamous cell carcinoma (LSCC) Hep-2 cells in nude mice. Methods: Xenograft model of human LSCC was established by subcutaneous transplantation of Hep-2 cells in 24 nude mice. The LSCC-bearing nude mice were randomly divided into 3 groups ( n =8 in each):DJ-1 siRNA low dose group and DJ-1 siRNA high dose group were injected in tumors with 20 μg of DJ-1 siRNA or 40 μg of DJ-1 siRNA in 50 μL, respectively; control group was injected with 5% glucose solution in 50 μL, twice a week for 3 weeks. The weight and size of tumors were measured before injection. The animals were sacrificed 48 h after the final treatment, and the tumors were harvested and weighed. The apoptosis and proliferation of tumor cells were determined; the expressions of Caspase-3 and Ki-67 in tumor specimens were detected with immunohistochemistry. The expression of DJ-1, PTEN, survivin mRNA and protein in tumor tissues were detected by RT-PCR and Western blotting, respectively. Results: Tumor weight in low dose group[(0.66±0.15)g] and high dose group[(0.48±0.11)g] were significantly lower than that in control group[(0.83±0.16)g, all P <0.05]. The inhibition rates of low dose group and high dose group were (20.48±0.18)% and (42.16±0.13)%, respectively. Immunohistochemistry showed that the expression of Caspase-3 was increased and Ki-67 was reduced in tumor specimens, compared with the control group (all P <0.05). RT-PCR and Western blot results showed that in low dose group and high dose group the mRNA and protein expression of DJ-1 and survivin significantly decreased (all P <0.05), while PTEN mRNA and protein content increased (all P <0.05). Conclusion: High dose DJ-1 siRNA can inhibit the tumor growth in human LSCC xenograft nude mouse model, which indicates that down-regulating DJ-1 and survivin, and up-regulating PTEN expression may lead to blockage of PI3K-PKB/Akt signaling pathway and promoting tumor cell apoptosis.
2013-01-01
Background Increasing the radiotherapy dose can result in improved local control for non-small-cell lung cancer (NSCLC) and can thereby improve survival. Accelerated hypofractionated radiotherapy can expose tumors to a high dose of radiation in a short period of time, but the optimal treatment regimen remains unclear. The purpose of this study was to evaluate the feasibility of utilizing high-dose accelerated hypofractionated three-dimensional conformal radiotherapy (at 3 Gy/fraction) with concurrent vinorelbine (NVB) and carboplatin (CBP) chemotherapy for the treatment of local advanced NSCLC. Methods Untreated patients with unresectable stage IIIA/IIIB NSCLC or patients with a recurrence of NSCLC received accelerated hypofractionated three-dimensional conformal radiotherapy. The total dose was greater than or equal to 60 Gy. The accelerated hypofractionated radiotherapy was conducted once daily at 3 Gy/fraction with 5 fractions per week, and the radiotherapy was completed in 5 weeks. In addition to radiotherapy, the patients also received at least 1 cycle of a concurrent two-drug chemotherapy regimen of NVB and CBP. Results A total of 26 patients (19 previously untreated cases and 7 cases of recurrent disease) received 60Gy-75Gy radiotherapy with concurrent chemotherapy. All of the patients underwent evaluations for toxicity and preliminary therapeutic efficacy. There were no treatment-related deaths within the entire patient group. The major acute adverse reactions were radiation esophagitis (88.5%) and radiation pneumonitis (42.3%). The percentages of grade III acute radiation esophagitis and grade III radiation pneumonitis were 15.4% and 7.7%, respectively. Hematological toxicities were common and did not significantly affect the implementation of chemoradiotherapy after supportive treatment. Two patients received high dose of 75 Gy had grade III late esophageal toxicity, and none had grade IV and above. Grade III and above late lung toxicity did not occur. Conclusion High-dose accelerated hypofractionated three-dimensional conformal radiotherapy with a dose of 60 Gy or greater with concurrent NVB and CBP chemotherapy might be feasible. However esophagus toxicity needs special attention. A phase I trial is recommended to obtain the maximum tolerated radiation dose of accelerated hypofractionated radiotherapy with concurrent chemotherapy. PMID:23937855
Zifodya, Jackson M; Challens, Cameron H C; Hsieh, Wen-Long
2016-06-01
When implementing Acuros XB (AXB) as a substitute for anisotropic analytic algorithm (AAA) in the Eclipse Treatment Planning System, one is faced with a dilemma of reporting either dose to medium, AXB-Dm or dose to water, AXB-Dw. To assist with decision making on selecting either AXB-Dm or AXB-Dw for dose reporting, a retrospective study of treated patients for head & neck (H&N), prostate, breast and lung is presented. Ten patients, previously treated using AAA plans, were selected for each site and re-planned with AXB-Dm and AXB-Dw. Re-planning was done with fixed monitor units (MU) as well as non-fixed MUs. Dose volume histograms (DVH) of targets and organs at risk (OAR), were analyzed in conjunction with ICRU-83 recommended dose reporting metrics. Additionally, comparisons of plan homogeneity indices (HI) and MUs were done to further highlight the differences between the algorithms. Results showed that, on average AAA overestimated dose to the target volume and OARs by less than 2.0 %. Comparisons between AXB-Dw and AXB-Dm, for all sites, also showed overall dose differences to be small (<1.5 %). However, in non-water biological media, dose differences between AXB-Dw and AXB-Dm, as large as 4.6 % were observed. AXB-Dw also tended to have unexpectedly high 3D maximum dose values (>135 % of prescription dose) for target volumes with high density materials. Homogeneity indices showed that AAA planning and optimization templates would need to be adjusted only for the H&N and Lung sites. MU comparison showed insignificant differences between AXB-Dw relative to AAA and between AXB-Dw relative to AXB-Dm. However AXB-Dm MUs relative to AAA, showed an average difference of about 1.3 % signifying an underdosage by AAA. In conclusion, when dose is reported as AXB-Dw, the effect that high density structures in the PTV has on the dose distribution should be carefully considered. As the results show overall small dose differences between the algorithms, when transitioning from AAA to AXB, no significant change to existing prescription protocols is expected. As most of the clinical experience is dose-to-water based and calibration protocols and clinical trials are also dose-to-water based and there still exists uncertainties in converting CT number to medium, selecting AXB-Dw is strongly recommended.
Sumino, Kaharu; Sugar, Elizabeth A.; Irvin, Charles G.; Kaminsky, David A.; Shade, Dave; Wei, Christine Y.; Holbrook, Janet T.; Wise, Robert A.; Castro, Mario
2014-01-01
Background The methacholine challenge test quantifies airway hyper-responsiveness, which is measured by the provocative concentration of methacholine causing a 20% decrease in forced expiration volume in 1 second (PC20). The dose–response effect of inhaled corticosteroids (ICS) on PC20 has been inconsistent and within-patient variability of PC20 is not well established. Objectives To determine the effect of high- vs low-dose ICS on PC20 and within-patient variability in those with repeated measurements of PC20. Methods A randomized, double-masked, crossover trial was conducted in patients with asthma on controller medications with PC20 of 8 mg/mL or lower (n = 64) to evaluate the effect of high-dose (1,000 μg/d) vs low-dose (250 μg/d) fluticasone for 4 weeks on PC20. In addition, the variability of PC20 was assessed in participants who underwent 2 or 3 PC20 measurements on the same dose of ICS (n = 27) over a 4-week interval. Results Because there was a significant period effect, dose comparison of the change in PC20 was assessed in the first treatment period. There was no significant difference in the change in PC20 for high- vs low-dose ICS (39% vs 30% increase, respectively; P = .87). The within- and between-participant variances for log PC20 were 0.84 and 0.96, respectively, with an intra-class correlation of 0.53, and 37% of participants had more than 2 doubling dose changes in PC20 in those with repeated measurements. Conclusion The effect of ICS on PC20 is not dose dependent at fluticasone levels of 250 and 1,000 μg/d. Interpersonal variability for PC20 is large. A lack of precise measurements should be taken into account when interpreting any change in PC20. PMID:24507830
de Abajo, Francisco J; García Rodríguez, Luis A
2001-01-01
Background The use of low-dose aspirin has been reported to be associated with an increased risk of upper gastrointestinal complications (UGIC). The coating of aspirin has been proposed as an approach to reduce such a risk. To test this hypothesis, we carried out a population based case-control study. Methods We identified incident cases of UGIC (bleeding or perforation) aged 40 to 79 years between April 1993 to October 1998 registered in the General Practice Research Database. Controls were selected randomly from the source population. Adjusted estimates of relative risk (RR) associated with current use of aspirin as compared to non use were computed using unconditional logistic regression. Results We identified 2,105 cases of UGIC and selected 11,500 controls. Among them, 287 (13.6%) cases and 837 (7.3%) controls were exposed to aspirin, resulting in an adjusted RR of 2.0 (1.7-2.3). No clear dose-effect was found within the range of 75-300 mg. The RR associated with enteric-coated formulations (2.3, 1.6-3.2) was similar to the one of plain aspirin (1.9, 1.6-2.3), and no difference was observed depending on the site. The first two months of treatment was the period of greater risk (RR= 4.5, 2.9-7.1). The concomitant use of aspirin with high-dose NSAIDs greatly increased the risk of UGIC (13.3, 8.5-20.9) while no interaction was apparent with low-medium doses (2.2, 1.0-4.6). Conclusions Low-dose aspirin increases by twofold the risk of UGIC in the general population and its coating does not modify the effect. Concomitant use of low-dose aspirin and NSAIDs at high doses put patients at a specially high risk of UGIC. PMID:11228592
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woods, K; Tran, A; Yu, V
Purpose: Thinning of the cerebral cortex has been observed in patients treated with fractionated partial brain radiation therapy and may contribute to cognitive decline following treatment. The extent of this thinning is dose-dependent, and was shown comparable to that of neurodegenerative diseases such as Alzheimer’s disease at one year post-therapy. This study investigates whether 4π radiotherapy can enable better sparing of the cortex and other critical structures when compared to conventional clinical IMRT plans. Methods: Clinical cortex-sparing IMRT plans for 15 high-grade glioma patients were included in this study. 4π radiotherapy plans were created for each patient with 20 intensity-modulatedmore » non-coplanar fields selected with a greedy column-generation optimization. All plans were normalized to deliver 100% of the prescribed dose to 95% of the planning target volume (PTV). The mean and maximum dose to the cerebral cortex and other organs at risk (OARs) were compared for the two plan types, as well as the conformity index (CI), homogeneity index (HI), and 50% dose spillage volume (R50). Results: The 4π plans significantly reduced the mean cortex dose by an average of 16% (range 6% to 27%) compared to the clinical plans. The mean dose to every other OAR compared was also reduced by 15% to 43%, with statistically significant reductions to the brainstem, chiasm, eyes, optic nerves, subcortical whit, and hippocampus. The average maximum doses were also reduced for 10/12 OARs. The R50 was significantly reduced with the 4π plans (>14%) and the homogeneity index was significantly improved. Conclusion: 4π enables significant sparing of the cerebral cortex when treating high-grade gliomas with fractionated partial brain radiation therapy, potentially reducing the risk of harmful dose-dependent cortical thinning. NIH R43CA183390, NIH R01CA188300, Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, C; Zhang, H; Chen, Y
Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of imagesmore » alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.« less
SU-E-T-765: Treatment Planning Comparison of SFUD Proton and 4Ï€ Radiotherapy for Prostate Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tran, A; Woods, K; Yu, V
2015-06-15
Purpose: Single-Field Uniform Dose (SFUD) proton scanning beams and non-coplanar 4π intensity-modulated radiation therapy (IMRT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate treatment. Methods: Five prostate patients were planned using 4π radiotherapy and SFUD to an initial dose of 54Gy to a planning target volume (PTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2Gy to the prostate for a total dose of 79.2 Gy. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams usingmore » a greedy column generation algorithm. The SFUD plans utilized two coplanar, parallel-opposing lateral scanning beams. The SFUD plan PTV was modified to account for range uncertainties while keeping an evaluation PTV identical to that of the X-ray plans for comparison. PTV doses, bladder and rectum dose volumes (V40, V45, V60, V70, V75.6, and V80), R50, and PTV homogeneity index (D95/D5) were evaluated. Results: Compared to SFUD, 4π resulted in 6.8% lower high dose spillage as indicated by R50. Bladder and rectum mean doses were 38.3% and 28.2% lower for SFUD, respectively. However, bladder and rectum volumes receiving >70Gy were 13.1% and 12% greater using proton SFUD. Due to the parallel-opposing beam arrangement, SFUD resulted in greater femoral head (87.8%) and penile bulb doses (43.7%). 4π PTV doses were slightly more homogeneous (HI 0.99 vs. 0.98) than the SFUD dose. Conclusion: Proton is physically advantageous to reduce the irradiated normal volume and mean doses to the rectum and bladder but it is also limited in the beam orientations and entrance dose, which resulted in greater doses to the femoral heads and penile bulb, and larger volumes of rectum and bladder exposed to high dose due to the required robust PTV definition. This project is supported by Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Candela-Juan, C., E-mail: ccanjuan@gmail.com; Niatsetski, Y.; Laarse, R. van der
Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a {sup 192}Ir source; (ii) to calculate by means of the Monte Carlo (MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The PENELOPE2008 MC code was used to optimize dwell positions and dwell times.more » Next, the dose distribution in a water phantom and the leakage dose distribution around the applicator were calculated. Finally, MC data were validated experimentally for a {sup 192}Ir mHDR-v2 source by measuring (i) dose distributions with radiochromic EBT3 films (ISP); (ii) percentage depth–dose (PDD) curve with the parallel-plate ionization chamber Advanced Markus (PTW); and (iii) absolute dose rate with EBT3 films and the PinPoint T31016 (PTW) ionization chamber. Results: The new applicator is made of tungsten alloy (Densimet) and consists of a set of interchangeable collimators. Three catheters are used to allocate the source at prefixed dwell positions with preset weights to produce a homogenous dose distribution at the typical prescription depth of 3 mm in water. The same plan is used for all available collimators. PDD, absolute dose rate per unit of air kerma strength, and off-axis profiles in a cylindrical water phantom are reported. These data can be used for treatment planning. Leakage around the applicator was also scored. The dose distributions, PDD, and absolute dose rate calculated agree within experimental uncertainties with the doses measured: differences of MC data with chamber measurements are up to 0.8% and with radiochromic films are up to 3.5%. Conclusions: The new applicator and the dosimetric data provided here will be a valuable tool in clinical practice, making treatment of large skin lesions simpler, faster, and safer. Also the dose to surrounding healthy tissues is minimal.« less
SU-F-J-86: Method to Include Tissue Dose Response Effect in Deformable Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, J; Liang, J; Chen, S
Purpose: Organ changes shape and size during radiation treatment due to both mechanical stress and radiation dose response. However, the dose response induced deformation has not been considered in conventional deformable image registration (DIR). A novel DIR approach is proposed to include both tissue elasticity and radiation dose induced organ deformation. Methods: Assuming that organ sub-volume shrinkage was proportional to the radiation dose induced cell killing/absorption, the dose induced organ volume change was simulated applying virtual temperature on each sub-volume. Hence, both stress and heterogeneity temperature induced organ deformation. Thermal stress finite element method with organ surface boundary condition wasmore » used to solve deformation. Initial boundary correspondence on organ surface was created from conventional DIR. Boundary condition was updated by an iterative optimization scheme to minimize elastic deformation energy. The registration was validated on a numerical phantom. Treatment dose was constructed applying both the conventional DIR and the proposed method using daily CBCT image obtained from HN treatment. Results: Phantom study showed 2.7% maximal discrepancy with respect to the actual displacement. Compared with conventional DIR, subvolume displacement difference in a right parotid had the mean±SD (Min, Max) to be 1.1±0.9(−0.4∼4.8), −0.1±0.9(−2.9∼2.4) and −0.1±0.9(−3.4∼1.9)mm in RL/PA/SI directions respectively. Mean parotid dose and V30 constructed including the dose response induced shrinkage were 6.3% and 12.0% higher than those from the conventional DIR. Conclusion: Heterogeneous dose distribution in normal organ causes non-uniform sub-volume shrinkage. Sub-volume in high dose region has a larger shrinkage than the one in low dose region, therefore causing more sub-volumes to move into the high dose area during the treatment course. This leads to an unfavorable dose-volume relationship for the normal organ. Without including this effect in DIR, treatment dose in normal organ could be underestimated affecting treatment evaluation and planning modification. Acknowledgement: Partially Supported by Elekta Research Grant.« less
The effective dose of different scanning protocols using the Sirona GALILEOS® comfort CBCT scanner
Bohay, R; Kaci, L; Barnett, R; Battista, J
2015-01-01
Objectives: To determine the effective dose and CT dose index (CTDI) for a range of imaging protocols using the Sirona GALILEOS® Comfort CBCT scanner (Sirona Dental Systems GmbH, Bensheim, Germany). Methods: Calibrated optically stimulated luminescence dosemeters were placed at 26 sites in the head and neck of a modified RANDO® phantom (The Phantom Laboratory, Greenwich, NY). Effective dose was calculated for 12 different scanning protocols. CTDI measurements were also performed to determine the dose–length product (DLP) and the ratio of effective dose to DLP for each scanning protocol. Results: The effective dose for a full maxillomandibular scan at 42 mAs was 102 ± 1 μSv and remained unchanged with varying contrast and resolution settings. This compares with 71 μSv for a maxillary scan and 76 μSv for a mandibular scan with identical milliampere-seconds (mAs) at high contrast and resolution settings. Conclusions: Changes to mAs and beam collimation have a significant influence on effective dose. Effective dose and DLP vary linearly with mAs. A collimated maxillary or mandibular scan decreases effective dose by approximately 29% and 24%, respectively, as compared with a full maxillomandibular scan. Changes to contrast and resolution settings have little influence on effective dose. This study provides data for setting individualized patient exposure protocols to minimize patient dose from ionizing radiation used for diagnostic or treatment planning tasks in dentistry. PMID:25358865
Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia
2015-01-01
Determining ionizing radiation in a geographic area serves to assess its effects on a population’s health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h−1. At the same sites, 48 soil samples were taken to obtain the activity concentrations of 226Ra, 232Th and 40K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h−1. Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg−1, for 226Ra, 232Th and 40K, respectively. From the analysis, the spatial distribution of 232Th, 226Ra and 40K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize. PMID:26437425
SU-E-CAMPUS-T-03: Four-Dimensional Dose Distribution Measurement Using Plastic Scintillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashimoto, M; Kozuka, T; Oguchi, M
2014-06-15
Purpose: To develop the detector for the four-dimensional dose distribution measurement. Methods: We made the prototype detector for four-dimensional dose distribution measurement using a cylindrical plastic scintillator (5 cm diameter) and a conical reflection grass. The plastic scintillator is used as a phantom. When the plastic scintillator is irradiated, the scintillation light was emitted according to absorbed dose distribution. The conical reflection grass was arranged to surround the plastic scintillator, which project to downstream the projection images of the scintillation light. Then, the projection image was reflected to 45 degree direction by flat reflection grass, and was recorded by camcorder.more » By reconstructing the three-dimensional dose distribution from the projection image recorded in each frame, we could obtain the four-dimensional dose distribution. First, we tested the characteristic according to the amount of emitted light. Then we compared of the light profile and the dose profile calculated with the radiotherapy treatment planning system. Results: The dose dependency of the amount of light showed linearity. The pixel detecting smaller amount of light had high sensitivity than the pixel detecting larger amount of light. However the difference of the sensitivity could be corrected from the amount of light detected in each pixel. Both of the depth light profile through the conical reflection grass and the depth dose profile showed the same attenuation in the region deeper than peak depth. In lateral direction, the difference of the both profiles was shown at outside field and penumbra region. We consider that the difference is occurred due to the scatter of the scintillation light in the plastic scintillator block. Conclusion: It was possible to obtain the amount of light corresponding to the absorbed dose distribution from the prototype detector. Four-dimensional dose distributions can be reconstructed with high accuracy by the correction of the scattered light.« less
Plasma Cannabinoid Concentrations during Dronabinol Pharmacotherapy for Cannabis Dependence
Milman, Garry; Bergamaschi, Mateus M.; Lee, Dayong; Mendu, Damodara R.; Barnes, Allan J.; Vandrey, Ryan; Huestis, Marilyn A.
2013-01-01
Background Recently, high-dose oral synthetic delta-9-tetrahydrocannabinol (THC) was shown to alleviate cannabis withdrawal symptoms. The present data describe cannabinoid pharmacokinetics in chronic daily cannabis smokers who received high-dose oral THC pharmacotherapy and later, a smoked cannabis challenge. Methods 11 daily cannabis smokers received 0, 30, 60, or 120 mg/day THC for four 5-day medication sessions, each separated by 9-days of ad-libitum cannabis smoking. On the 5th day, participants were challenged with smoking one 5.9% THC cigarette. Plasma collected on the 1st and 5th days was quantified by GC-GC-MS for THC, 11-hydroxy-THC (11-OH-THC), and 11-nor-9-carboxy-THC (THCCOOH). Linear ranges (ng/mL) were 0.5–100 for THC, 1–50 11-OH-THC, and 0.5–200 THCCOOH. Results During placebo dosing, THC, 11-OH-THC and THCCOOH concentrations consistently decreased, while all cannabinoids increased dose-dependently during active dronabinol administration. THC increase over time was not significant after any dose, 11-OH-THC increased significantly during 60 and 120 mg/day doses, and THCCOOH increased significantly only during the 120 mg/day dose. THC and 11-OH-THC, and THCCOOH concentrations peaked within 0.25 h after cannabis smoking, except after 120 mg/day THC when THCCOOH peaked 0.5 h before smoking. Conclusions The significant withdrawal effects noted during placebo dronabinol administration were supported by significant plasma THC and 11-OH-THC concentration decreases. During active dronabinol dosing, significant dose-dependent increases in THC and 11-OH-THC concentrations support withdrawal symptom suppression. THC concentrations after cannabis smoking were only distinguishable from oral THC doses for 1 h, too short a period to feasibly identify cannabis relapse. THCCOOH/THC ratios were higher 14 h after overnight oral dronabinol abstinence, but cannot distinguish oral THC dosing from smoked cannabis intake. PMID:24067260
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.
2011-07-15
Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less
Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia
2015-09-30
Determining ionizing radiation in a geographic area serves to assess its effects on a population's health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h(-1). At the same sites, 48 soil samples were taken to obtain the activity concentrations of (226)Ra, (232)Th and (40)K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h(-1). Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg(-1), for (226)Ra, (232)Th and (40)K, respectively. From the analysis, the spatial distribution of (232)Th, (226)Ra and (40)K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize.
Radioactivity concentrations in soils in the Qingdao area, China.
Qu, Limei; Yao, De; Cong, Pifu; Xia, Ning
2008-10-01
The specific activity concentrations of radionuclides (238)U, (232)Th, and (40)K of 2300 sampling points in the Qingdao area were measured by an FD-3022 gamma-ray spectrometer. The radioactivity concentrations of (238)U, (232)Th, and (40)K ranged from 3.3 to 185.3, from 6.9 to 157.2, and from 115.8 to 7834.4 Bq kg(-1), respectively. The air-absorbed dose at 1 meter above ground, effective annual dose, external hazard index, and radium equivalent activity were also calculated to systematically evaluate the radiological hazards of the natural radioactivity in Qingdao. The air-absorbed dose, effective annual dose, external hazard index, and radium equivalent activity in the study area were 98.6 nGy h(-1), 0.12 mSv, 0.56, 197 Bq kg(-1), respectively. Compared with the worldwide value, the air-absorbed dose is slightly high, but the other factors are all lower than the recommended value. The natural external exposure will not pose significant radiological threat to the population. In conclusion, the Qingdao area is safe with regard to the radiological level and suitable for living.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sher, David J., E-mail: david_sher@rush.edu; Fidler, Mary Jo; Seder, Christopher W.
Purpose: To compare, using the National Cancer Database, survival, pathologic, and surgical outcomes in patients with stage IIIA non-small cell lung cancer treated with differential doses of neoadjuvant chemoradiation therapy, with the aim to discern whether radiation dose escalation was associated with a comparative effectiveness benefit and/or toxicity risk. Methods and Materials: Patients in the National Cancer Database with stage IIIA non-small cell lung cancer treated with neoadjuvant chemoradiation therapy and surgery between 1998 and 2005 were analyzed. Dose strata were divided between 36 to 45 Gy (low-dose radiation therapy, LD-RT), 45 to 54 Gy (inclusive, standard-dose, SD-RT), and 54 to 74 Gymore » (high-dose, HD-RT). Outcomes included overall survival, residual nodal disease, positive surgical margin status, hospital length of stay, and adverse surgical outcomes (30-day mortality or readmission). Results: The cohort consisted of 1041 patients: 233 (22%) LD-RT, 584 (56%) SD-RT, and 230 (22%) HD-RT. The median, 3-year, and 5-year overall survival outcomes were 34.9 months, 48%, and 37%, respectively. On univariable analysis, patients treated with SD-RT experienced prolonged overall survival (median 38.3 vs 31.8 vs 29.0 months for SD-RT, LD-RT, and HD-RT, respectively, P=.0089), which was confirmed on multivariable analysis (hazard ratios 0.77 and 0.81 vs LD and HD, respectively). Residual nodal disease was seen less often after HD-RT (25.5% vs 31.8% and 37.5% for HD-RT, LD-RT, and SD-RT, respectively, P=.0038). Patients treated with SD-RT had fewer prolonged hospital stays. There were no differences in positive surgical margin status or adverse surgical outcomes between the cohorts. Conclusions: Neoadjuvant chemoradiation therapy between 45 and 54 Gy was associated with superior survival in comparison with doses above and below this threshold. Although this conclusion is limited by selection bias, clear candidates for trimodality therapy do not seem to achieve additional benefit with dose escalation.« less
2010-01-01
Background Luteinizing hormone-releasing hormone (LHRH) is an exogenous hormone commonly used to induce spermiation in anuran amphibians. Over the past few decades, the LHRH dose administered to individuals and the frequency of injection has been highly variable. The sperm-release responses reported have been correspondingly diverse, highlighting a need to quantify dose-response relationships on a species-specific basis. This study on the Australian anuran Pseudophryne guentheri first evaluated the spermiation response of males administered one of five LHRHa doses, and second, determined whether AVT administered in combination with the optimal LHRHa dose improved sperm-release. Methods Male toadlets were administered a single dose of 0, 1, 2, 4 or 8 micrograms/g body weight of LHRHa. A 4 micrograms/g dose of AVT was administered alone or in combination with 2 micrograms/g LHRHa. Spermiation responses were evaluated at 3, 7 and 12 h post hormone administration (PA), and sperm number and viability were quantified using fluorescent microscopy. Results LHRHa administration was highly effective at inducing spermiation in P. guentheri, with 100% of hormone-treated males producing sperm during the experimental period. The number of sperm released in response to 2 micrograms/g LHRHa was greater than all other doses administered and sperm viability was highest in the 1 microgram/g treatment. The administration of AVT alone or in combination with LHRHa resulted in the release of significantly lower sperm numbers. Conclusion Overall, results from this study suggest that in P. guentheri, LHRHa is effective at inducing spermiation, but that AVT inhibits sperm-release. PMID:21059269
Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure
2012-01-01
Background According to a fundamental law of radiobiology (“Law of Bergonié and Tribondeau”, 1906), the brain is a paradigm of a highly differentiated organ with low mitotic activity, and is thus radio-resistant. This assumption has been challenged by recent evidence discussed in the present review. Results Ionizing radiation is an established environmental cause of brain cancer. Although direct evidence is lacking in contemporary fluoroscopy due to obvious sample size limitation, limited follow-up time and lack of focused research, anecdotal reports of clusters have appeared in the literature, raising the suspicion that brain cancer may be a professional disease of interventional cardiologists. In addition, although terminally differentiated neurons have reduced or mild proliferative capacity, and are therefore not regarded as critical radiation targets, adult neurogenesis occurs in the dentate gyrus of the hippocampus and the olfactory bulb, and is important for mood, learning/memory and normal olfactory function, whose impairment is a recognized early biomarker of neurodegenerative diseases. The head doses involved in radiotherapy are high, usually above 2 Sv, whereas the low-dose range of professional exposure typically involves lifetime cumulative whole-body exposure in the low-dose range of < 200 mSv, but with head exposure which may (in absence of protection) arrive at a head equivalent dose of 1 to 3 Sv after a professional lifetime (corresponding to a brain equivalent dose around 500 mSv). Conclusions At this point, a systematic assessment of brain (cancer and non-cancer) effects of chronic low-dose radiation exposure in interventional cardiologists and staff is needed. PMID:22540409
Berrouiguet, Sofian; Barrigón, Maria Luisa; Brandt, Sara A.; Ovejero-García, Santiago; Álvarez-García, Raquel; Carballo, Juan Jose; Lenca, Philippe; Courtet, Philippe; Baca-García, Enrique
2016-01-01
Purpose The emergence of electronic prescribing devices with clinical decision support systems (CDSS) is able to significantly improve management pharmacological treatments. We developed a web application available on smartphones in order to help clinicians monitor prescription and further propose CDSS. Method A web application (www.MEmind.net) was developed to assess patients and collect data regarding gender, age, diagnosis and treatment. We analyzed antipsychotic prescriptions in 4345 patients attended in five Psychiatric Community Mental Health Centers from June 2014 to October 2014. The web-application reported average daily dose prescribed for antipsychotics, prescribed daily dose (PDD), and the PDD to defined daily dose (DDD) ratio. Results The MEmind web-application reported that antipsychotics were used in 1116 patients out of the total sample, mostly in 486 (44%) patients with schizophrenia related disorders but also in other diagnoses. Second generation antipsychotics (quetiapine, aripiprazole and long-acting paliperidone) were preferably employed. Low doses were more frequently used than high doses. Long acting paliperidone and ziprasidone however, were the only two antipsychotics used at excessive dosing. Antipsychotic polypharmacy was used in 287 (26%) patients with classic depot drugs, clotiapine, amisulpride and clozapine. Conclusions In this study we describe the first step of the development of a web application that is able to make polypharmacy, high dose usage and off label usage of antipsychotics visible to clinicians. Current development of the MEmind web application may help to improve prescription security via momentary feedback of prescription and clinical decision support system. PMID:27764107
2012-01-01
Background Cytokines may be elevated in tumor and normal tissues following irradiation. Cytokine expression in these tissues may predict for toxicity or tumor control. The purpose of this pilot study was to determine the feasibility of measuring local salivary cytokine levels using buccal sponges in patients receiving chemo-radiation for head and neck malignancies. Patients and methods 11 patients with epithelial malignancies of the head and neck were recruiting to this study. All patients received radiotherapy to the head and neck region with doses ranging between 60 – 67.5 Gy. Chemotherapy was delivered concurrently with radiation in all patients. Salivary samples were obtained from high dose and low dose regions prior to treatment and at three intervals during treatment for assessment of cytokine levels (IL-4, IL-6, IL-8, IL-10, EGF, MCP-1, TNF-α, and VEGF). Results Cytokine levels were detectable in the salivary samples. Salivary cytokine levels of IL-4, IL-6, IL-8, EGF, MCP-1, TNF- α , and VEGF were higher in the high dose region compared to the low dose region at all time points (p < 0.05). A trend toward an increase in cytokine levels as radiation dose increased was observed for IL-6, IL-8, MCP-1, and TNF-α. Conclusion Assessment of salivary cytokine levels may provide a novel method to follow local cytokine levels during radiotherapy and may provide a mechanism to study cytokine levels in a regional manner. PMID:22537315
Dose-Effect Relationships for Recurrence of Keloid and Pterygium After Surgery and Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kal, Henk B.; Veen, Ronald E.; Juergenliemk-Schulz, Ina M.
2009-05-01
Purpose: To show radiation dose-response relationships for recurrence of keloid and pterygium after radiotherapy following surgery. Methods and Materials: Using PubMed, we performed a retrospective review of articles reporting incidences and/or dose-response relationships for recurrence of keloid and pterygium after radiotherapy following surgery. The irradiation regimens identified were normalized by use of the linear-quadratic model; biologically effective doses (BEDs) were calculated. Results: For keloid recurrence after radiotherapy following keloid removal, with either teletherapy or brachytherapy, the recurrence rate after having delivered a BED greater than 30 Gy is less than 10%. For pterygium recurrence after bare sclera surgery and {supmore » 90}Sr {beta}-irradiation, a BED of about 30 Gy seems to be sufficient also to reduce the recurrence rate to less than 10%. Conclusions: Most of the doses in the radiotherapy schemes used for prevention of keloid recurrence after surgery are too low. In contrast, the doses applied in most regimens to prevent pterygium recurrence are too high. A scheme with a BED of 30 to 40 Gy seems to be sufficient to prevent recurrences of keloid as well as pterygium.« less
SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gotz, M; Karsch, L; Pawelke, J
Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fitmore » of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future investigations. This project was funded by the German ministry of research and education (BMBF) under grant number: 03Z1N511 and by the state of Saxony under grant number: B 209.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Halabi, Hani; Paetzold, Peter; Sharp, Gregory C.
2015-07-15
Purpose: Severe (Radiation Therapy Oncology Group [RTOG] grade 3 or greater) esophagitis generally occurs in 15% to 25% of non–small cell lung cancer (NSCLC) patients undergoing concurrent chemotherapy and radiation therapy (CCRT), which may result in treatment breaks that compromise local tumor control and pose a barrier to dose escalation. Here, we report a novel contralateral esophagus-sparing technique (CEST) that uses intensity modulated radiation therapy (IMRT) to reduce the incidence of severe esophagitis. Methods and Materials: We reviewed consecutive patients with thoracic malignancies undergoing curative CCRT in whom CEST was used. The esophageal wall contralateral (CE) to the tumor wasmore » contoured as an avoidance structure, and IMRT was used to guide a rapid dose falloff gradient beyond the target volume in close proximity to the esophagus. Esophagitis was recorded based on the RTOG acute toxicity grading system. Results: We identified 20 consecutive patients treated with CCRT of at least 63 Gy in whom there was gross tumor within 1 cm of the esophagus. The median radiation dose was 70.2 Gy (range, 63-72.15 Gy). In all patients, ≥99% of the planning and internal target volumes was covered by ≥90% and 100% of prescription dose, respectively. Strikingly, no patient experienced grade ≥3 esophagitis (95% confidence limits, 0%-16%) despite the high total doses delivered. The median maximum dose, V45, and V55 of the CE were 60.7 Gy, 2.1 cc, and 0.4 cc, respectively, indicating effective esophagus cross-section sparing by CEST. Conclusion: We report a simple yet effective method to avoid exposing the entire esophagus cross-section to high doses. By using proposed CE dose constraints of V45 <2.5 cc and V55 <0.5 cc, CEST may improve the esophagus toxicity profile in thoracic cancer patients receiving CCRT even at doses above the standard 60- to 63-Gy levels. Prospective testing of CEST is warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos, A; Institute for Photonics and Advanced Sensing and School of Chem and Phys, Adelaide, South Australia; Mohammadi, M
Purpose: Beryllium oxide (BeO) ceramics have an effective atomic number, zeff ∼7.1, closely matched to water, zeff ∼7.4. The purpose of this study was to evaluate the use of a beryllium oxide (BeO) ceramic fibrecoupled luminescence dosimeter, named RL/OSL BeO FOD, for high dose rate (HDR) brachytherapy dosimetry. In our dosimetry system the radioluminescence (RL) of BeO ceramics is utilized for dose-rate measurements, and the optically stimulated luminescence (OSL) can be read post exposure for accumulated dose measurements. Methods: The RL/OSL BeO FOD consists of a 1 mm diameter × 1 mm long cylinder of BeO ceramic coupled to amore » 15 m long silica-silica optical fibre. The optical fibre is connected to a custom developed portable RL and OSL reader, located outside of the treatment suite. The x-ray energy response was evaluated using superficial x-rays, an Ir-192 source and high energy linear accelerators. The RL/OSL BeO FOD was then characterised for an Ir-192 source, investigating the dose response and angular dependency. A depth dose curve for the Ir-192 source was also measured. Results: The RL/OSL BeO FOD shows an under-response at low energy x-rays as expected. Though at higher x-ray energies, the OSL response continued to increase, while the RL response remained relatively constant. The dose response for the RL is found to be linear up to doses of 15 Gy, while the OSL response becomes more supralinear to doses above 15 Gy. Little angular dependency is observed and the depth dose curve measured agreed within 4% of that calculated based on TG-43. Conclusion: This works shows that the RL/OSL BeO FOD can be useful in HDR dosimetry. With the RL/OSL BeO FODs current size, it is capable of being inserted into intraluminal catheters and interstitial needles to verify HDR treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferreyra, M; Salinas Aranda, F; Dodat, D
Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical andmore » dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.« less
SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shusharina, N; Khan, F; Sharp, G
2015-06-15
Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT wasmore » designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.« less
Cho, Soyun; Lee, Serah; Lee, Min-Jung; Lee, Dong Hun; Won, Chong-Hyun; Kim, Sang Min
2009-01-01
Background No studies have yet been undertaken to determine the effect of aloe gel on the clinical signs and biochemical changes of aging skin. Objective We wanted to determine whether dietary aloe vera gel has anti-aging properties on the skin. Methods Thirty healthy female subjects over the age of 45 were recruited and they received 2 different doses (low-dose: 1,200 mg/d, high-dose: 3,600 mg/d) of aloe vera gel supplementation for 90 days. Their baseline status was used as a control. At baseline and at completion of the study, facial wrinkles were measured using a skin replica, and facial elasticity was measured by an in vivo suction skin elasticity meter. Skin samples were taken before and after aloe intake to compare the type I procollagen and matrix metalloproteinase 1 (MMP-1) mRNA levels by performing real-time RT-PCR. Results After aloe gel intake, the facial wrinkles improved significantly (p<0.05) in both groups, and facial elasticity improved in the lower-dose group. In the photoprotected skin, the type I procollagen mRNA levels were increased in both groups, albeit without significance; the MMP-1 mRNA levels were significantly decreased in the higher-dose group. Type I procollagen immunostaining was substantially increased throughout the dermis in both groups. Conclusion Aloe gel significantly improves wrinkles and elasticity in photoaged human skin, with an increase in collagen production in the photoprotected skin and a decrease in the collagen-degrading MMP-1 gene expression. However, no dose-response relationship was found between the low-dose and high-dose groups. PMID:20548848
Gleeson, Molly D; Guzman, David Sanchez-Migallon; Knych, Heather K; Kass, Philip H; Drazenovich, Tracy L; Hawkins, Michelle G
2018-01-01
OBJECTIVE To determine the pharmacokinetics and sedative effects of 2 doses of a concentrated buprenorphine formulation after SC administration to red-tailed hawks (Buteo jamaicensis). ANIMALS 6 adult red-tailed hawks. PROCEDURES Concentrated buprenorphine (0.3 mg/kg, SC) was administered to all birds. Blood samples were collected at 10 time points over 24 hours after drug administration to determine plasma buprenorphine concentrations. After a 4-week washout period, the same birds received the same formulation at a higher dose (1.8 mg/kg, SC), and blood samples were collected at 13 time points over 96 hours. Hawks were monitored for adverse effects and assigned agitation-sedation scores at each sample collection time. Plasma buprenorphine concentrations were quantified by liquid chromatography-tandem mass spectrometry. RESULTS Mean time to maximum plasma buprenorphine concentration was 7.2 minutes and 26.1 minutes after administration of the 0.3-mg/kg and 1.8-mg/kg doses, respectively. Plasma buprenorphine concentrations were > 1 ng/mL for mean durations of 24 and 48 hours after low- and high-dose administration, respectively. Mean elimination half-life was 6.23 hours for the low dose and 7.84 hours for the high dose. Mean agitation-sedation scores were higher (indicating some degree of sedation) than the baseline values for 24 hours at both doses. No clinically important adverse effects were observed. CONCLUSIONS AND CLINICAL RELEVANCE Concentrated buprenorphine was rapidly absorbed, and plasma drug concentrations considered to have analgesic effects in other raptor species were maintained for extended periods. Most birds had mild to moderate sedation. Additional studies are needed to evaluate the pharmacodynamics of these doses of concentrated buprenorphine in red-tailed hawks.
Lovelock, D. Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya
2011-01-01
Purpose In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials The minimum doses received by the hottest 100%, 98%, and 95% (Dmin, D98, and D95) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18–24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12–14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV Dmin, D98, and D95 for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for Dmin, D98, and D95 were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions The results indicate that Dmin, D98, and D95 may be important risk factors for local failure. No local failures in any histology were observed when Dmin was >15 Gy, suggesting that this metric may be an important predictor of local control. PMID:20350795
Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura
PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to proceduremore » type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.« less
Bridging the gap: a review of dose investigations in paediatric investigation plans
Hampson, Lisa V; Herold, Ralf; Posch, Martin; Saperia, Julia; Whitehead, Anne
2014-01-01
Aims In the EU, development of new medicines for children should follow a prospectively agreed paediatric investigation plan (PIP). Finding the right dose for children is crucial but challenging due to the variability of pharmacokinetics across age groups and the limited sample sizes available. We examined strategies adopted in PIPs to support paediatric dosing recommendations to identify common assumptions underlying dose investigations and the attempts planned to verify them in children. Methods We extracted data from 73 PIP opinions recently adopted by the Paediatric Committee of the European Medicines Agency. These opinions represented 79 medicinal development programmes and comprised a total of 97 dose investigation studies. We identified the design of these dose investigation studies, recorded the analyses planned and determined the criteria used to define target doses. Results Most dose investigation studies are clinical trials (83 of 97) that evaluate a single dosing rule. Sample sizes used to investigate dose are highly variable across programmes, with smaller numbers used in younger children (< 2 years). Many studies (40 of 97) do not pre-specify a target dose criterion. Of those that do, most (33 of 57 studies) guide decisions using pharmacokinetic data alone. Conclusions Common assumptions underlying dose investigation strategies include dose proportionality and similar exposure−response relationships in adults and children. Few development programmes pre-specify steps to verify assumptions in children. There is scope for the use of Bayesian methods as a framework for synthesizing existing information to quantify prior uncertainty about assumptions. This process can inform the design of optimal drug development strategies. PMID:24720849
The Effect of Intra-articular Corticosteroids on Articular Cartilage
Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.
2015-01-01
Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laack, Nadia N.; Ballman, Karla V.; Mayo Clinic Cancer Center, Rochester, MN
Purpose: The aim of this study was to evaluate the efficacy, toxicity, and survival of whole-brain radiotherapy-treated (WBRT) and high-dose methylprednisolone (HDMP)-treated in elderly patients with primary central nervous system lymphoma (PCNSL). Methods and Materials: Patients with PCNSL who were 70 years and older received 1 g of methylprednisolone daily for 5 days, 30 days after WBRT. Patients then received 1 g of methylprednisolone every 28 days until progression. The primary endpoint was overall survival (OS) at 6 months. Results were compared with those in patients on the previous North Central Cancer Treatment Group (NCCTG) trial who received pre-WBRT cytoxan,more » adriamycin, vincristine, prednisone (CHOP) and high-dose cytarabine (CHOP-WBRT). A planned interim analysis was performed. The current regimen would be considered inactive if survival was not improved from patients treated with CHOP-WBRT. Results: Nineteen patients were accrued between 1998 and 2003. Median age was 76 years. Interim analysis revealed a 6-month survival of 33%, resulting in closure of the trial. Toxicity, OS, and event-free survival (EFS) were similar to those in patients more than 70 years of age who received CHOP-WBRT. The subgroup of patients who received HDMP had longer OS (12.1 vs. 7.0 months, p = 0.76) and EFS (11.7 vs. 4.0 months, p = 0.04) compared with the CHOP-WBRT patients alive 60 days after the start of treatment. Conclusions: Patients on-study long enough to receive HDMP had prolongation of OS and EFS compared to patients receiving CHOP-WBRT. Although the numbers of patients are too small for statistical conclusions, the HDMP regimen deserves further study.« less
Light Delivery Over Extended Time Periods Enhances the Effectiveness of Photodynamic Therapy
Seshadri, Mukund; Bellnier, David A.; Vaughan, Lurine A.; Spernyak, Joseph A.; Mazurchuk, Richard; Foster, Thomas H.; Henderson, Barbara W.
2009-01-01
Purpose The rate of energy delivery is a principal factor determining the biological consequences of photodynamic therapy (PDT). In contrast to conventional high irradiance treatments, recent preclinical and clinical studies have focused on low irradiance schemes. The objective of this study was to investigate the relationship between irradiance, photosensitizer dose and PDT dose with regard to treatment outcome and tumor oxygenation in a rat tumor model. Experimental Design Using the photosensitizer HPPH (2-[1-hexyloxyethyl]-2 devinyl pyropheophorbide), a wide range of PDT doses that included clinically relevant photosensitizer concentrations were evaluated. Magnetic resonance imaging (MRI) and oxygen tension measurements were performed along with the Evans blue exclusion assay to assess vascular response, oxygenation status and tumor necrosis. Results In contrast to high incident laser power (150 mW), low power regimens (7 mW) yielded effective tumor destruction. This was largely independent of PDT dose (drug-light product), with up to 30-fold differences in photosensitizer dose and 15-fold differences in drug-light product. For all drug-light products, the duration of light treatment positively influenced tumor response. Regimens utilizing treatment times of 120–240 mins showed marked reduction in signal intensity in T2-weighted MR images at both low (0.1 mg/kg) and high (3 mg/kg) drug doses compared to short duration (6–11 mins) regimens. Significantly greater reductions in pO2 were observed with extended exposures, which persisted after completion of treatment. Conclusions These results confirm the benefit of prolonged light exposure, identify vascular response as a major contributor and suggest that duration of light treatment (time) may be an important new treatment parameter. PMID:18451247
Schneider, Lynda C.; Rachid, Rima; LeBovidge, Jennifer; Blood, Emily; Mittal, Mudita; Umetsu, Dale T.
2015-01-01
Background Peanut allergy is a major public health problem that affects 1% of the population and has no effective therapy. Objective To examine the safety and efficacy of oraldesensitization in peanut allergic children in combination with a brief course of anti-IgE monoclonal antibody (omalizumab, Xolair). Methods We performed oral peanut desensitization in peanut allergic children at high risk for developing significant peanut-induced allergic reactions. Omalizumab was administered prior to and during oral peanut desensitization. Results We enrolled 13 children (median age, 10 years), with a median peanut-specific IgE of 229 kUA/L and a median total serum IgE of 621 kU/L, who failed an initial double-blind placebo controlled food challenge at doses 100 mg peanut flour. After pre-treatment with omalizumab, all subjects tolerated the initial 11 desensitization doses given on the first day, including the maximum dose of 500 mg peanut flour (cumulative dose, 992 mg, equivalent to >2 peanuts), requiring minimal or no rescue therapy. 12 subjects then reached the maximum maintenance dose of 4,000 mg peanut flour/day in a median time of 8 weeks, at which point omalizumab was discontinued. All 12 subjects continued on 4,000 mg peanut flour/day and subsequently tolerated a challenge with 8,000 mg peanut flour (equivalent to about 20 peanuts), or 160 to 400 times the dose tolerated before desensitization. During the study, 6 of the 13 subjects experienced mild or no allergic reactions; 6 subjects had Grade 2, and 2 subjects Grade 3 reactions, all of which responded rapidly to treatment. Conclusions Among children with high-risk peanut allergy, treatment with omalizumab may facilitate rapid oral desensitization, and qualitativelyimprove the desensitization process. PMID:24176117
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yasmin-Karim, S; Makrigiorgos, GM; Moreau, M
Purpose: Oraya Therapy uses low-voltage, stereotactic, highly targeted X-rays for the treatment of wet age-related macular degeneration (AMD) — offering a new option for patients worldwide. Neovascular endothelial cells play a crucial role in the pathogenesis of this disease. This in-vitro study investigates the potential of gold nanoparticles (GNP) to enhance endothelial cell damage during low-voltage radiotherapy towards potential applications in the treatment of wet-AMD. Methods: Primary human umbilical cord vein endothelium cells (HUVEC) were treated with 1.4 nm sized GNPs for 24 hrs and then irradiated with variable X-ray doses using an Oraya therapy system (100 kVp) or amore » Small Animal Radiation and Research platform (SARRP) at other beam qualities (up to 220 kVp). Radio-sensitization was assessed by clonogenic assays. Variable concentrations of GNPs (0.05 mg/ml, 0.1 mg/ml, 0.25 mg/ml, 0.5 mg/ml, and 1 mg/ml) where employed. The dose enhancement factor (DEF) was calculated as the ratio of radiation doses required to give the same biological effect (survival factor, SF) with and without GNPs. Results: Preliminary results show DEFs of up to 2.62 for the different combinations of x-ray doses and GNP concentrations and beam qualities. In general the DEF increased with increase in GNP concentration. However, for high doses the effect of GNP becomes less apparent likely due to already high cell kill by the radiation alone. Conclusion: The findings suggest that targeted GNPs can play a significant synergistic role in enhancing stereotactic radiosurgery for wet AMD. The results also provide impetus for ongoing studies to find the optimal synergy between the doses or beam energies and GNPs concentration. This will benefit in-vivo studies towards development of nanoparticle-aided radiotherapy for treatment of wet-AMD and potentially ocular cancers.« less
AAV5-Factor VIII Gene Transfer in Severe Hemophilia A.
Rangarajan, Savita; Walsh, Liron; Lester, Will; Perry, David; Madan, Bella; Laffan, Michael; Yu, Hua; Vettermann, Christian; Pierce, Glenn F; Wong, Wing Y; Pasi, K John
2017-12-28
Patients with hemophilia A rely on exogenous factor VIII to prevent bleeding in joints, soft tissue, and the central nervous system. Although successful gene transfer has been reported in patients with hemophilia B, the large size of the factor VIII coding region has precluded improved outcomes with gene therapy in patients with hemophilia A. We infused a single intravenous dose of a codon-optimized adeno-associated virus serotype 5 (AAV5) vector encoding a B-domain-deleted human factor VIII (AAV5-hFVIII-SQ) in nine men with severe hemophilia A. Participants were enrolled sequentially into one of three dose cohorts (low dose [one participant], intermediate dose [one participant], and high dose [seven participants]) and were followed through 52 weeks. Factor VIII activity levels remained at 3 IU or less per deciliter in the recipients of the low or intermediate dose. In the high-dose cohort, the factor VIII activity level was more than 5 IU per deciliter between weeks 2 and 9 after gene transfer in all seven participants, and the level in six participants increased to a normal value (>50 IU per deciliter) that was maintained at 1 year after receipt of the dose. In the high-dose cohort, the median annualized bleeding rate among participants who had previously received prophylactic therapy decreased from 16 events before the study to 1 event after gene transfer, and factor VIII use for participant-reported bleeding ceased in all the participants in this cohort by week 22. The primary adverse event was an elevation in the serum alanine aminotransferase level to 1.5 times the upper limit of the normal range or less. Progression of preexisting chronic arthropathy in one participant was the only serious adverse event. No neutralizing antibodies to factor VIII were detected. The infusion of AAV5-hFVIII-SQ was associated with the sustained normalization of factor VIII activity level over a period of 1 year in six of seven participants who received a high dose, with stabilization of hemostasis and a profound reduction in factor VIII use in all seven participants. In this small study, no safety events were noted, but no safety conclusions can be drawn. (Funded by BioMarin Pharmaceutical; ClinicalTrials.gov number, NCT02576795 ; EudraCT number, 2014-003880-38 .).
Argnani, Fiorenza; Camillo, Mauro Di; Marinaro, Vanessa; Foglietta, Tiziana; Avallone, Veronica; Cannella, Carlo; Vernia, Piero
2008-01-01
AIM: To evaluate the prevalence of lactose intolerance (LI) following a load of 12.5 g in patients diagnosed as high-grade malabsorbers using the hydrogen breath test (HBT)-25. METHODS: Ninety patients showing high-grade malabsorption at HBT-25 were submitted to a second HBT with a lactose load of 12.5 g. Peak hydrogen production, area under the curve of hydrogen excretion and occurrence of symptoms were recorded. RESULTS: Only 16 patients (17.77%) with positive HBT-25 proved positive at HBT-12.5. Hydrogen production was lower as compared to HBT-25 (peak value 21.55 parts per million (ppm) ± 29.54 SD vs 99.43 ppm ± 40.01 SD; P < 0.001). Symptoms were present in only 13 patients. The absence of symptoms during the high-dose test has a high negative predictive value (0.84) for a negative low-dose test. The presence of symptoms during the first test was not useful for predicting a positive low-dose test (positive predictive value 0.06-0.31). CONCLUSION: Most patients with a positive HBT-25 normally absorb a lower dose of lactose and a strict lactose restriction on the basis of a “standard” HBT is, in most instances, unnecessary. Thus, the 25 g lactose tolerance test should probably be substituted by the 12.5 g test in the diagnosis of LI, and in providing dietary guidelines to patients with suspected lactose malabsorption/intolerance. PMID:18985811
DOE Office of Scientific and Technical Information (OSTI.GOV)
Audet, C; Poffenbarger, B; Hwang, A
2015-06-15
Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetrymore » was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.« less
Glucosamine enhances paracetamol bioavailability by reducing its metabolism.
Qinna, Nidal A; Shubbar, Maryam H; Matalka, Khalid Z; Al-Jbour, Nawzat; Ghattas, Mohammad A; Badwan, Adnan A
2015-01-01
Paracetamol has an extensive first-pass metabolism that highly affects its bioavailability (BA); thus, dose may be repeated several times a day in order to have longer efficacy. However, hepatotoxicity may arise because of paracetamol metabolism. Therefore, this project aimed to increase paracetamol BA in rats by glucosamine (GlcN). At GlcN-paracetamol racemic mixture ratio of 4:1 and paracetamol dose of 10 mg/kg, paracetamol area under the curve (AUC) and maximum concentration (Cmax ) were significantly increased by 99% and 66%, respectively (p < 0.05). Furthermore, paracetamol AUC and Cmax levels were increased by 165% and 88% in rats prefed with GlcN for 2 days (p < 0.001). Moreover, GlcN significantly reduced phase Ι and phase I/ΙΙ metabolic reactions in liver homogenate by 48% and 54%, respectively. Furthermore, GlcN molecule was found to possess a good in silico binding mode into the CYP2E1 active site-forming bidentate hydrogen bonding with the Thr303 side chain. Finally, serum ALT and AST levels of rats-administered high doses of paracetamol were significantly reduced when rats were prefed with GlcN (p < 0.01). In conclusion, GlcN can increase the relative BA of paracetamol through reducing its metabolism. This phenomenon is associated with reduction in hepatocytes injury following ingestion of high doses of paracetamol. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
2010-01-01
Background Local control in adjuvant/definitive RT of adenoid cystic carcinoma (ACC) is largely dose-dependent. However, some clinical situations do not allow application of tumouricidal doses (i.e. re-irradiation) hence radiation sensitization by exploitation of high endothelial growth factor receptor (EGFR)-expression in ACC seems beneficial. This is a single-institution experience of combined radioimmunotherapy (RIT) with the EGFR-inhibitor cetuximab. Methods Between 2006 and 2010, 9 pts received RIT for advanced/recurrent ACC, 5/9 pts as re-irradiation. Baseline characteristics as well as treatment parameters were retrieved to evaluate efficacy and toxicity of the combination regimen were evaluated. Control rates (local/distant) and overall survival were calculated using Kaplan-Meier estimation. Results Median dose was 65 Gy, pts received a median of 6 cycles cetuximab. RIT was tolerated well with only one °III mucositis/dysphagia. Overall response/remission rates were high (77,8%); 2-year estimate of local control was 80% hence reaching local control levels comparable to high-dose RT. Progression-free survival (PFS) at 2 years and median overall survival were only 62,5% and 22,2 mo respectively. Conclusion While local control and treatment response in RIT seems promising, PFS and overall survival are still hampered by distant failure. The potential benefit of RIT with cetuximab warrants exploration in a prospective controlled clinical trial. PMID:21047402
Belcher, Leigh A; MacKenzie, Susan A; Donner, Maria; Sykes, Greg P; Frame, Steven R; Gillies, Peter J
2011-02-01
The 28-day repeat-dose oral and genetic toxicity of eicosapentaenoic acid triglyceride oil (EPA oil) produced from genetically modified Yarrowia lipolytica yeast were assessed. Groups of rats received 0 (olive oil), 940, 1880, or 2820 mg EPA oil/kg/day, or fish oil (sardine/anchovy source) by oral gavage. Lower total serum cholesterol was seen in all EPA and fish oil groups. Liver weights were increased in the medium and high-dose EPA (male only), and fish oil groups but were considered non-adverse physiologically adaptive responses. Increased thyroid follicular cell hypertrophy was observed in male high-dose EPA and fish oil groups, and was considered to be an adaptive response to high levels of polyunsaturated fatty acids. No adverse test substance-related effects were observed on body weight, nutritional, or other clinical or anatomic pathology parameters. The oil was not mutagenic in the in vitro Ames or mouse lymphoma assay, and was not clastogenic in the in vivo mouse micronucleus test. In conclusion, exposure for 28 days to EPA oil derived from yeast did not produce adverse effects at doses up to 2820 mg/kg/day and was not genotoxic. The safety profile of the EPA oil in these tests was comparable to a commercial fish oil. Copyright © 2010 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurosawa, T; Moriya, S; Sato, M
2015-06-15
Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additionalmore » constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.« less
qiuxia, Zhang; xinlong, Ma; yilong, Yang; hui, Zhao; yali, Wang; xiaoquan, Yao; lei, Wang; jiahui, Chang; haiyan, Zou
2017-01-01
Background: Jieyuanshen decoction (JYAS-D) - a traditional Chinese medicine was invented by Professor Nie based on classic formulas, chaihu jia longgu muli decoction has been proved as having favorable curative effects on depression in clinical practices. The aim of this study was to investigate the antidepressant effects and its molecular mechanism of JYAS-D. Materials and Methods: The model of depression was established by Chronic Unpredictable Stress. Different doses (8.2 g/kg, 16.3 g/kg, 32.7 g/kg) of JYAS-D was orally administered; Fluoxetine was orally administered with 10mg/kg. All treatments lasted for 28 days. Sucrose preference and open-field tests were adopted to observe the behavior of rats. OPA (ortho-phthalaldehyde) derivatization method was used to detect the contents of amino acid neurotransmitter. RIA (Radiation immunity analysis) method was used to measure the serum concentrations of CORT (Corticosterone), ACTH (Adrenocorticotropic hormone) and CRH (Corticotropin-releasing hormone). ELISA (Enzyme linked immunosorbent assay) method was adopted to examine the contents of Glucocorticoid receptor (GR) and Mineralocorticoid receptor (MR) in hippocampus. Results: Compared with the model group, sucrose preference was increased in all treatment groups. The concentration of serum CORT was reduced in the middle dose of JYAS-D and control groups; the concentration of serum ACTH was reduced in the low and high-dose of JYAS-D; the concentration of serum CRH was reduced in the middle and high-dose of JYAS-D. The content of hippocampus GR was increased in the middle and high-dose of JYAS-D; the content of hippocampus Glu (Glutamic acid) was reduced among the low, middle and high-dose of JYAS-D and fluoxetine group, the ratio of Glu/γ-GABA (y-aminobutyric acid was reduced in the low and high-dose of JYAS-D. Conclusion: JYAS-D had a significant antidepressant-like effect on rat model through regulating serum concentration of CORT, ACTH and CRH, increasing the content of hippocampus GR and regulating the equilibrium of amino acids neurotransmitter. PMID:28573220
Accuracy of Reduced-Dose Computed Tomography for Ureteral Stones in Emergency Department Patients
Moore, Christopher L.; Daniels, Brock; Ghita, Monica; Gunabushanam, Gowthaman; Luty, Seth; Molinaro, Annette M.; Singh, Dinesh; Gross, Cary P.
2016-01-01
Study objective Reduced-dose computed tomography (CT) scans have been recommended for diagnosis of kidney stone but are rarely used in the emergency department (ED) setting. Test characteristics are incompletely characterized, particularly in obese patients. Our primary outcome is to determine the sensitivity and specificity of a reduced-dose CT protocol for symptomatic ureteral stones, particularly those large enough to require intervention, using a protocol stratified by patient size. Methods This was a prospective, blinded observational study of 201 patients at an academic medical center. Consenting subjects underwent both regular- and reduced-dose CT, stratified into a high and low body mass index (BMI) protocol based on effective abdominal diameter. Reduced-dose CT scans were interpreted by radiologists blinded to regular-dose interpretations. Follow-up for outcome and intervention was performed at 90 days. Results CT scans with both regular and reduced doses were conducted for 201 patients, with 63% receiving the high BMI reduced-dose protocol. Ureteral stone was identified in 102 patients (50.7%) of those receiving regular-dose CT, with a ureteral stone greater than 5 mm identified in 26 subjects (12.9%). Sensitivity of the reduced-dose CT for any ureteral stone was 90.2% (95% confidence interval [CI] 82.3% to 95.0%), with a specificity of 99.0% (95% CI 93.7% to 100.0%). For stones greater than 5 mm, sensitivity was 100% (95% CI 85.0% to 100.0%). Reduced-dose CT identified 96% of patients who required intervention for ureteral stone within 90 days. Mean reduction in size-specific dose estimate was 18.6 milligray (mGy), from 21.7 mGy (SD 9.7) to 3.4 mGy (SD 0.9). Conclusion CT with substantial dose reduction was 90.2% (95% CI 82.3% to 95.0%) sensitive and 98.9% (95% CI 85.0% to 100.0%) specific for ureteral stones in ED patients with a wide range of BMIs. Reduced-dose CT was 96.0% (95% CI 80.5% to 99.3%) sensitive for ureteral stones requiring intervention within 90 days. PMID:25441242
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H; Gopalakrishnan, M; Lee, P
2014-06-01
Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according tomore » the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.« less
Hall, Jeffrey S.; Franson, J. Christian; Gill, Robert E.; Meteyer, Carol U.; TeSlaa, Joshua L.; Nashold, Sean W.; Dusek, Robert J.; Ip, Hon S.
2011-01-01
Conclusions Dunlin are highly susceptible to infection with HPAIV H5N1. They become infected after exposure to relatively small doses of the virus and if they become infected, they are most likely to suffer mortality within 3–5 days. These results have important implications regarding the risks of transport and transmission of HPAIV H5N1 to North America by this species and raises questions for further investigation.
Treatment of recurrent Clostridium difficile infection: a systematic review
O'Horo, J. C.; Jindai, K.; Kunzer, B.; Safdar, N.
2014-01-01
Background Clostridium difficile infection (CDI) recurs in nearly one-third of patients who develop an initial infection. Recurrent CDI (RCDI) is associated with considerable morbidity, mortality, and cost. Treatment for RCDI has not been not well examined. Methods A systematic review. Results Sixty-four articles were identified evaluating eight different treatment approaches: metronidazole, vancomycin, fidaxomicin, nitazoxanide, rifampin, immunoglobulins, probiotics, and fecal bacteriotherapy. The meta-analysis found vancomycin to have a similar efficacy to metronidazole, although studies used varying doses and durations of therapy. Fidaxomicin was slightly more efficacious than vancomycin, though the number of studies was small. Good evidence for probiotics was limited. Fecal bacteriotherapy was found to be highly efficacious in a single randomized trial. Conclusion Metronidazole and vancomycin have good evidence for use in RCDI but heterogeneity in treatment duration and dose precludes robust conclusions. Fidaxomicin may have a role in treatment, but evidence is limited to subgroup analyses. Fecal bacteriotherapy was the most efficacious. Saccharomyces boulardii may have a role as adjunctive treatment. PMID:23839210
Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Men Chunhua; Romeijn, H. Edwin; Jia Xun
2010-11-15
Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider a cost function consisting two terms, the first enforcing a desired dose distribution and the second guaranteeing a smooth dose rate variation between successive gantry angles. A gantry rotation is discretized into 180 beam angles and for each beam angle, only one MLC aperture is allowed. The apertures are generated one by one in a sequentialmore » way. At each iteration of the column generation method, a deliverable MLC aperture is generated for one of the unoccupied beam angles by solving a subproblem with the consideration of MLC mechanic constraints. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. When all 180 beam angles are occupied, the optimization completes, yielding a set of deliverable apertures and associated dose rates that produce a high quality plan. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation without any couch/collimator rotations. High quality VMAT plans have been generated for all ten cases with extremely high efficiency. It takes only 5-8 min on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18-31 s on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such plans. Conclusions: The authors have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable high quality treatment plans at very high efficiency.« less
Chavez-Santoscoy, Rocío A.; Lecona-Guzmán, Carlos A.; Bogdanchikova, Nina; Salinas-Ruíz, Josafhat; Gómez-Merino, Fernando Carlos; Pestryakov, Alexey
2017-01-01
Background: Hormesis is considered a dose–response phenomenon characterized by growth stimulation at low doses and inhibition at high doses. The hormetic response by silver nanoparticles (AgNPs) on in vitro multiplication of sugarcane was evaluated using a temporary immersion system. Methods: Sugarcane shoots were used as explants cultured in Murashige and Skoog medium with AgNPs at concentrations of 0, 25, 50, 100, and 200 mg/L. Shoot multiplication rate and length were used to determine hormetic response. Total content of phenolic compounds of sugarcane, mineral nutrition, and reactive oxygen species (ROS) was determined. Results: Results were presented as a dose–response curve. Stimulation phase growth was observed at 50 mg/L AgNPs, whereas inhibition phase was detected at 200 mg/L AgNPs. Mineral nutrient analysis showed changes in macronutrient and micronutrient contents due to the effect of AgNPs. Moreover, AgNPs induced ROS production and increased total phenolic content, with a dose-dependent effect. Conclusion: Results suggested that the production of ROS and mineral nutrition are key mechanisms of AgNP-induced hormesis and that phenolic accumulation was obtained as a response of the plant to stress produced by high doses of AgNPs. Therefore, small doses of AgNPs in the culture medium could be an efficient strategy for commercial micropropagation. PMID:29238274
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schüler, Emil; Trovati, Stefania; King, Gregory
Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlomore » and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.« less
Oseltamivir Pharmacokinetics, Dosing, and Resistance Among Children Aged <2 Years With Influenza
Kimberlin, David W.; Acosta, Edward P.; Prichard, Mark N.; Sánchez, Pablo J.; Ampofo, Krow; Lang, David; Ashouri, Negar; Vanchiere, John A.; Abzug, Mark J.; Abughali, Nazha; Caserta, Mary T.; Englund, Janet A.; Sood, Sunil K.; Spigarelli, Michael G.; Bradley, John S.; Lew, Judy; Michaels, Marian G.; Wan, Wen; Cloud, Gretchen; Jester, Penelope; Lakeman, Fred D.; Whitley, Richard J.; Giles, Dusty; Cotton, Bari; Judy, Sharon; Cowie, Margaret; Francis, Jeanne; Evans, Candice; O'Donnell, Nan; Shiraishi, Ofelia Vargas; Latiolais, Lisa; Aymami, Valeri; Dole, Ken; Gaultier, Julie; Lofthus, Gerry; Kinnunen, Diane; Lacombe, Kirsten; Stellato, Nancy; Denlinger, Julie; Hingtgen, Sara; Mason, Christina; Jeffrey, Noreen
2013-01-01
Background. Children <2 years of age are at high risk of influenza-related mortality and morbidity. However, the appropriate dose of oseltamivir for children <2 years of age is unknown. Methods. The National Institute of Allergy and Infectious Diseases Collaborative Antiviral Study Group evaluated oseltamivir in infants aged <2 years in an age–de-escalation, adaptive design with a targeted systemic exposure. Results. From 2006 to 2010, 87 subjects enrolled. An oseltamivir dose of 3.0 mg/kg produced drug exposures within the target range in subjects 0–8 months of age, although there was a greater degree of variability in infants <3 months of age. In subjects 9–11 months of age, a dose of 3.5 mg/kg produced drug exposures within the target range. Six of 10 subjects aged 12–23 months receiving the Food and Drug Administration–approved unit dose for this age group (ie, 30 mg) had oseltamivir carboxylate exposures below the target range. Virus from 3 subjects developed oseltamivir resistance during antiviral treatment. Conclusions. The appropriate twice-daily oral oseltamivir dose for infants ≤8 months of age is 3.0 mg/kg, while the dose for infants 9–11 months old is 3.5 mg/kg. Clinical Trials Registration. NCT00391768. PMID:23230059
Palm tocotrienol-rich fraction inhibits methionine-induced cystathionine β-synthase in rat liver.
Kamisah, Yusof; Norsidah, Ku-Zaifah; Azizi, Ayob; Faizah, Othman; Nonan, Mohd Rizal; Asmadi, Ahmad Yusof
2015-12-01
Oxidative stress plays an important role in cardiovascular diseases. The study investigated the effects of dietary palm tocotrienol-rich fraction on homocysteine metabolism in rats fed a high-methionine diet. Forty-two male Wistar rats were randomly assigned to six groups. Five groups were fed with high-methionine diet (1%) for 10 weeks. Groups 2 to 5 were also given dietary folate (8 mg/kg) and three doses of palm tocotrienol-rich fraction (30, 60 and 150 mg/kg) from week 6 to week 10. The last group was only given basal rat chow. High-methionine diet increased plasma homocysteine after 10 weeks, which was prevented by the supplementations of folate and high-dose palm tocotrienol-rich fraction. Hepatic S-adenosyl methionine (SAM) content was unaffected in all groups but S-adenosyl homocysteine (SAH) content was reduced in the folate group. Folate supplementation increased the SAM/SAH ratio, while in the palm tocotrienol-rich fraction groups, the ratio was lower compared with the folate. Augmented activity of hepatic cystathionine β-synthase and lipid peroxidation content by high-methionine diet was inhibited by palm tocotrienol-rich fraction supplementations (moderate and high doses), but not by folate. The supplemented groups had lower hepatic lipid peroxidation than the high-methionine diet. In conclusion, palm tocotrienol-rich fraction reduced high-methionine-induced hyperhomocysteinaemia possibly by reducing hepatic oxidative stress in high-methionine-fed rats. It may also exert a direct inhibitory effect on hepatic cystathionine β-synthase.
Taghizadeh, Mohsen; Memarzadeh, Mohammad Reza; Abedi, Fatemeh; Sharifi, Nasrin; Karamali, Fatemeh; Fakhrieh Kashan, Zohreh; Asemi, Zatollah
2016-01-01
Background Limited data are available regarding the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight subjects. Objectives The current study aimed to assess the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight. Patients and Methods This randomized double-blind placebo-controlled clinical trial was conducted on 72 subjects with overweight, aged 18 - 50 years old. Participants were randomly divided into three groups: Group A received high-dose Cumin cyminum L. and lime capsules (75 mg each, n = 24), group B low-dose Cumin cyminum L. and lime capsules (25 mg each, n = 24) and group C placebos (n = 24) twice daily for eight weeks. Results After eight weeks of intervention, compared with low-dose C. cyminum L. plus lime and placebo, taking high-dose C. cyminum L. plus lime resulted in significant weight loss (in the high-dose group: -2.1 ± 1.7 vs. in the low-dose group: -1.2 ± 1.5 and in the placebo group: + 0.2 ± 1.3 kg, respectively; P < 0.001) and body mass index (-0.8 ± 0.6 vs. -0.5 ± 0.5 and +0.1 ± 0.5 kg/m2, respectively; P < 0.001). In addition, administration of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo, led to a significant reduction in fasting plasma glucose (FPG) (P < 0.001) and a significant rise in quantitative insulin sensitivity check index (QUICKI) (+ 0.02 ± 0.02 vs. + 0.01 ± 0.02 and 0.01 ± 0.01, respectively; P = 0.01). Moreover, a significant decrease in serum triglycerides (-14.1 ± 56.2 vs. +13.9 ± 36.8 and + 10.6 ± 25.1 mg/dL; respectively; P = 0.03), total-cholesterol (-18.4 ± 28.6 vs. +8.6 ± 28.5 and -1.0 ± 24.8 mg/dL; respectively; P = 0.004) and low density lipoproteins- (LDL)-cholesterol levels (-11.8 ± 20.7 vs. +6.5 ± 23.2 and -2.9 ± 20.4 mg/dL, respectively; P = 0.01) was observed following the consumption of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo. Conclusions Results of the current study indicated that taking high-dose C. cyminum L. plus lime for eight weeks among subjects with overweight had beneficial effects on weight, BMI, FPG, QUICKI, triglycerides, total-cholesterol and LDL-cholesterol levels. PMID:27781121
Estcourt, Lise J; Stanworth, Simon; Doree, Carolyn; Trivella, Marialena; Hopewell, Sally; Blanco, Patricia; Murphy, Michael F
2015-01-01
Background Platelet transfusions are used in modern clinical practice to prevent and treat bleeding in people who are thrombocytopenic due to bone marrow failure. Although considerable advances have been made in platelet transfusion therapy in the last 40 years, some areas continue to provoke debate, especially concerning the use of prophylactic platelet transfusions for the prevention of thrombocytopenic bleeding. This is an update of a Cochrane review first published in 2004, and updated in 2012 that addressed four separate questions: prophylactic versus therapeutic-only platelet transfusion policy; prophylactic platelet transfusion threshold; prophylactic platelet transfusion dose; and platelet transfusions compared to alternative treatments. This review has now been split into four smaller reviews; this review compares different platelet transfusion doses. Objectives To determine whether different doses of prophylactic platelet transfusions (platelet transfusions given to prevent bleeding) affect their efficacy and safety in preventing bleeding in people with haematological disorders undergoing myelosuppressive chemotherapy with or without haematopoietic stem cell transplantation (HSCT). Search methods We searched for randomised controlled trials in the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Library 2015, Issue 6), MEDLINE (from 1946), Embase (from 1974), CINAHL (from 1937), the Transfusion Evidence Library (from 1950), and ongoing trial databases to 23 July 2015. Selection criteria Randomised controlled trials involving transfusions of platelet concentrates, prepared either from individual units of whole blood or by apheresis, and given to prevent bleeding in people with malignant haematological disorders or undergoing HSCT that compared different platelet component doses (low dose 1.1 × 1011/m2 ± 25%, standard dose 2.2 × 1011/m2 ± 25%, high dose 4.4 × 1011/m2 ± 25%). Data collection and analysis We used the standard methodological procedures expected by The Cochrane Collaboration. Main results We included seven trials (1814 participants) in this review; six were conducted during one course of treatment (chemotherapy or HSCT). Overall the methodological quality of studies was low to moderate across different outcomes according to GRADE methodology. None of the included studies were at low risk of bias in every domain, and all the included studies had some threats to validity. Five studies reported the number of participants with at least one clinically significant bleeding episode within 30 days from the start of the study. There was no difference in the number of participants with a clinically significant bleeding episode between the low-dose and standard-dose groups (four studies; 1170 participants; risk ratio (RR) 1.04, 95% confidence interval (CI) 0.95 to 1.13; moderate-quality evidence); low-dose and high-dose groups (one study; 849 participants; RR 1.02, 95% CI 0.93 to 1.11; moderate-quality evidence); or high-dose and standard-dose groups (two studies; 951 participants; RR 1.02, 95% CI 0.93 to 1.11; moderate-quality evidence). Three studies reported the number of days with a clinically significant bleeding event per participant. There was no difference in the number of days of bleeding per participant between the low-dose and standard-dose groups (two studies; 230 participants; mean difference −0.17, 95% CI −0.51 to 0.17; low quality evidence). One study (855 participants) showed no difference in the number of days of bleeding per participant between high-dose and standard-dose groups, or between low-dose and high-dose groups (849 participants). Three studies reported the number of participants with severe or life-threatening bleeding. There was no difference in the number of participants with severe or life-threatening bleeding between a low-dose and a standard-dose platelet transfusion policy (three studies; 1059 participants; RR 1.33, 95% CI 0.91 to 1.92; low-quality evidence); low-dose and high-dose groups (one study; 849 participants; RR 1.20, 95% CI 0.82 to 1.77; low-quality evidence); or high-dose and standard-dose groups (one study; 855 participants; RR 1.11, 95% CI 0.73 to 1.68; low-quality evidence). Two studies reported the time to first bleeding episodes; we were unable to perform a meta-analysis. Both studies (959 participants) individually found that the time to first bleeding episode was either the same, or longer, in the low-dose group compared to the standard-dose group. One study (855 participants) found that the time to the first bleeding episode was the same in the high-dose group compared to the standard-dose group. Three studies reported all-cause mortality within 30 days from the start of the study. There was no difference in all-cause mortality between treatment arms (low-dose versus standard-dose: three studies; 1070 participants; RR 2.04, 95% CI 0.70 to 5.93; low-quality evidence; low-dose versus high-dose: one study; 849 participants; RR 1.33, 95% CI 0.50 to 3.54; low-quality evidence; and high-dose versus standard-dose: one study; 855 participants; RR 1.71, 95% CI 0.51 to 5.81; low-quality evidence). Six studies reported the number of platelet transfusions; we were unable to perform a meta-analysis. Two studies (959 participants) out of three (1070 participants) found that a low-dose transfusion strategy led to more transfusion episodes than a standard-dose. One study (849 participants) found that a low-dose transfusion strategy led to more transfusion episodes than a high-dose strategy. One study (855 participants) out of three (1007 participants) found no difference in the number of platelet transfusions between the high-dose and standard-dose groups. One study reported on transfusion reactions. This study’s authors suggested that a high-dose platelet transfusion strategy may lead to a higher rate of transfusion-related adverse events. None of the studies reported quality-of-life. Authors’ conclusions In haematology patients who are thrombocytopenic due to myelosuppressive chemotherapy or HSCT, we found no evidence to suggest that a low-dose platelet transfusion policy is associated with an increased bleeding risk compared to a standard-dose or high-dose policy, or that a high-dose platelet transfusion policy is associated with a decreased risk of bleeding when compared to a standard-dose policy. A low-dose platelet transfusion strategy leads to an increased number of transfusion episodes compared to a standard-dose strategy. A high-dose platelet transfusion strategy does not decrease the number of transfusion episodes per participant compared to a standard-dose regimen, and it may increase the number of transfusion-related adverse events. Findings from this review would suggest a change from current practice, with low-dose platelet transfusions used for people receiving in-patient treatment for their haematological disorder and high-dose platelet transfusion strategies not being used routinely. PMID:26505729
Naltrexone treatment for opioid dependence: Does its effectiveness depend on testing the blockade?
Sullivan, Maria A.; Bisaga, Adam; Mariani, John J.; Glass, Andrew; Levin, Frances R.; Comer, Sandra D.; Nunes, Edward V.
2013-01-01
Background FDA approval of long-acting injectable naltrexone (Vivitrol) for opioid dependence highlights the relevance of understanding mechanisms of antagonist treatment. Principles of learning suggest an antagonist works through extinguishing drug-seeking behavior, as episodes of drug use (“testing the blockade”) fail to produce reinforcement. We hypothesized that opiate use would moderate the effect of naltrexone, specifically, that opiate-positive urines precede dropout in the placebo group, but not in the active-medication groups. Methods An 8-week, double-blind, placebo-controlled trial (N=57), compared the efficacy of low (192-mg) and high (384-mg) doses of a long-acting injectable naltrexone (Depotrex) with placebo (Comer et al., 2006). A Cox proportional hazard model was fit, modeling time-to-dropout as a function of treatment assignment and urine toxicology during treatment. Results Interaction of opiate urines with treatment group was significant. Opiate-positive urines predicted dropout on placebo and low-dose, but less so on high-dose naltrexone, where positive urines were more likely followed by sustained abstinence. Among patients with no opiate-positive urines, retention was higher in both low- and high-dose naltrexone conditions, compared to placebo. Conclusions Findings confirm that injection naltrexone produces extinction of drug-seeking behavior after episodes of opiate use. Adequate dosage appears important, as low-dose naltrexone resembled the placebo group; opiate positive urines were likely to be followed by dropout from treatment. The observation of high treatment retention among naltrexone-treated patients who do not test the blockade, suggests naltrexone may also exert direct effects on opiate-taking behavior that do not depend on extinction, perhaps by attenuating craving or normalizing dysregulated hedonic or neuroendocrine systems. PMID:23827259
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Angelillo, Rolando M., E-mail: r.dangelillo@unicampus.it; Sciuto, Rosa; Ramella, Sara
Purpose: To retrospectively review data of a cohort of patients with biochemical progression after radical prostatectomy, treated according to a uniform institutional treatment policy, to evaluate toxicity and feasibility of high-dose salvage radiation therapy (80 Gy). Methods and Materials: Data on 60 patients with biochemical progression after radical prostatectomy between January 2009 and September 2011 were reviewed. The median value of prostate-specific antigen before radiation therapy was 0.9 ng/mL. All patients at time of diagnosis of biochemical recurrence underwent dynamic {sup 18}F-choline positron emission tomography/computed tomography (PET/CT), which revealed in all cases a local recurrence. High-dose salvage radiation therapy was delivered up tomore » total dose of 80 Gy to 18F-choline PET/CT-positive area. Toxicity was recorded according to the Common Terminology Criteria for Adverse Events, version 3.0, scale. Results: Treatment was generally well tolerated: 54 patients (90%) completed salvage radiation therapy without any interruption. Gastrointestinal grade ≥2 acute toxicity was recorded in 6 patients (10%), whereas no patient experienced a grade ≥2 genitourinary toxicity. No grade 4 acute toxicity events were recorded. Only 1 patient (1.7%) experienced a grade 2 gastrointestinal late toxicity. With a mean follow-up of 31.2 months, 46 of 60 patients (76.6%) were free of recurrence. The 3-year biochemical progression-free survival rate was 72.5%. Conclusions: At early follow-up, {sup 18}F-choline PET/CT-driven high-dose salvage radiation therapy seems to be feasible and well tolerated, with a low rate of toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, TL; Martin, JA; Shepard, AJ
2014-06-15
Purpose: The large dose-response variation in both tumor and normal cells between individual patients has led to the recent implementation of predictive bioassays of patient-specific radiation sensitivity in order to personalize radiation therapy. This exciting new clinical paradigm has led us to develop a novel high-throughput, variable dose-rate irradiator to accompany these efforts. Here we present the biological validation of this irradiator through the use of human cells as a relative dosimeter assessed by two metrics, DNA double-strand break repair pathway modulation and intercellular reactive oxygen species production. Methods: Immortalized human tonsilar epithelial cells were cultured in 96-well micro titermore » plates and irradiated in groups of eight wells to absorbed doses of 0, 0.5, 1, 2, 4, and 8 Gy. High-throughput immunofluorescent microscopy was used to detect γH2AX, a DNA double-strand break repair mechanism recruiter. The same analysis was performed with the cells stained with CM-H2DCFDA that produces a fluorescent adduct when exposed to reactive oxygen species during the irradiation cycle. Results: Irradiations of the immortalized human tonsilar epithelial cells at absorbed doses of 0, 0.5, 1, 2, 4, and 8 Gy produced excellent linearity in γH2AX and CM-H2DCFDA with R2 values of 0.9939 and 0.9595 respectively. Single cell gel electrophoresis experimentation for the detection of physical DNA double-strand breaks in ongoing. Conclusions: This work indicates significant potential for our high-throughput variable dose rate irradiator for patient-specific predictive radiation sensitivity bioassays. This irradiator provides a powerful tool by increasing the efficiency and number of assay techniques available to help personalize radiation therapy.« less
XU, XIAOPING; LI, XIAOHUA; ZHANG, LEI; LIU, ZHAOHUI; PAN, YUAN; CHEN, DONG; BIN, DONGHUA; DENG, QUN; SUN, YU; HOFFMAN, M. ROBERT; YANG, ZHIJIAN; YUAN, HONG
2017-01-01
Background/Aim: Hemorrhoidectomy is often associated with significant postoperative complications that may result in slow wound healing. The traditional Chinese medicine (TCM) compound Sophora flavescens (CSF) has shown efficacy on many inflammatory disorders. The aim of the present study was to examine the efficacy of CSF on wound healing in a rat model of perianal ulceration. Materials and Methods: A rat model of perianal ulceration was induced by subcutaneous injection of 75% glacial acetic acid. The animals with induced perianal ulcer received topical treatment of low, medium, and high doses of CFS twice daily. Potassium permanganate (PP); 0.02%) was given to the animals for comparison. Macroscopic and histological assessments of the ulcerated area were performed after treatment. The expression of pro-inflammatory cytokines prostaglandin E2 (PGE2) and interleukin-8 (IL-8) was detected by immunohistochemical analysis. Results: Topical administration of medium- and high-dose CSF significantly enhanced perianal ulcer healing as compared to the untreated control (p<0.05). The macroscopic ulceration score was significantly reduced only in the high-dose CSF-treated group as compared to the control (p<0.01). All doses of CSF and PP ameliorated histological damages in the rats with induced perianal ulceration. High-dose CSF or PP significantly reduced the expression of PGE2 and IL-8 as compared to the control (p<0.01). No treatment-related toxicity was found in either the CSF- or the PP-treated mice. Conclusion: CSF enhances wound healing in a rat model of perianal ulceration. The inhibitory effect of CSF on pro-inflammatory cytokines PGE2 and IL-8 may be involved in the mechanism of enhanced wound-healing. PMID:28652418
NASA Astrophysics Data System (ADS)
Choi, Eun-Jin; Jeong, Moon-Taeg; Jang, Seong-Joo; Choi, Nam-Gil; Han, Jae-Bok; Yang, Nam-Hee; Dong, Kyung-Rae; Chung, Woon-Kwan; Lee, Yun-Jong; Ryu, Young-Hwan; Choi, Sung-Hyun; Seong, Kyeong-Jeong
2014-01-01
This study examined whether scanning could be performed with minimum dose and minimum exposure to the patient after an attenuation correction. A Hoffman 3D Brain Phantom was used in BIO_40 and D_690 PET/CT scanners, and the CT dose for the equipment was classified as a low dose (minimum dose), medium dose (general dose for scanning) and high dose (dose with use of contrast medium) before obtaining the image at a fixed kilo-voltage-peak (kVp) and milliampere (mA) that were adjusted gradually in 17-20 stages. A PET image was then obtained to perform an attenuation correction based on an attenuation map before analyzing the dose difference. Depending on tube current in the range of 33-190 milliampere-second (mAs) when BIO_40 was used, a significant difference in the effective dose was observed between the minimum and the maximum mAs (p < 0.05). According to a Scheffe post-hoc test, the ratio of the minimum to the maximum of the effective dose was increased by approximately 5.26-fold. Depending on the change in the tube current in the range of 10-200 mA when D_690 was used, a significant difference in the effective dose was observed between the minimum and the maximum of mA (p < 0.05). The Scheffe posthoc test revealed a 20.5-fold difference. In conclusion, because effective exposure dose increases with increasing operating current, it is possible to reduce the exposure limit in a brain scan can be reduced if the CT dose can be minimized for a transmission scan.
Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tao, Yinghua; Chen, Guang-Hong; Hacker, Timothy A.
Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan wasmore » performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937.9% for the 500 mA FBP, 25 mA SIR, and 25 mA FBP, respectively. In numerical simulations, SIR mitigated streak artifacts in the low dose data and yielded flow maps with mean error <7% and standard deviation <9% of mean, for 30×30 pixel ROIs (12.9 × 12.9 mm{sup 2}). In comparison, low dose FBP flow errors were −38% to +258%, and standard deviation was 6%–93%. Additionally, low dose SIR achieved 4.6 times improvement in flow map CNR{sup 2} per unit input dose compared to low dose FBP. Conclusions: SIR reconstruction can reduce image noise and mitigate streaking artifacts caused by photon starvation in dynamic CT myocardial perfusion data sets acquired at low dose (low tube current), and improve perfusion map quality in comparison to FBP reconstruction at the same dose.« less
Li, X; Han, K Q; Shi, Y N; Men, S Z; Li, S; Sun, M H; Dong, H; Lu, J J; Ma, L J; Zhao, M; Li, D; Liu, W
2017-02-07
Objective: To investigate the effects and possible mechanisms of ursodeoxycholic acid (UDCA) on myocardial fibrosis in mice. Method: To observe the expression of transforming growth factor(TGF) -β1, CTGF, MMPs and the degree of myocardial fibrosis, 61 male Kunming mice were randomly divided into normal group, low dose UDCA group, high dose of UDCA group, spironolactone group, and the control group.Isoproterenol (ISO) injection was given subcutaneously (30 d) to make the model of myocardial fibrosis.Corresponding anti-fibrosis drugs (UDCA or spironolactone) were given by gavage.HE staining and Masson staining were performed to explore the inflammation and fibrosis in the myocardium.The expression of collagen Ⅰ and collagen Ⅲ protein was detected by immunohistochemistry to evaluate the degree of fibrosis among the groups.Western blot was used to detect the expression of transforming growth factor, (TGF)-β1, connective tissue growth factor (CTGF), matrix metalloproteinase (MMP)-2, -9, tissue inhibitor of metalloproteinase (TIMP)-4, -1 and anti-phospho-NFKBIA (p-IκB-α) inhibitor of NF-κB (IκB) protein in myocardium. Results: HE and Masson staining results showed that in the normal group, myocardial fibrosis is less, while the control group showed a large amount of fibrotic tissue ( P <0.05). Tissue fibrosis in the low/high dose UDCA group and spironolactone group was significantly reduced compared with the control group ( P <0.05), in which high dose of UDCA reduces fibrosis more significantly.Immunohistochemistry results showed that collagen Ⅰ and collagen Ⅲ protein expression was significantly increased ( P <0.05). Whereas in the low/high UDCA dose group and spironolactone group, collagen Ⅰ and collagen Ⅲ expression were significantly decreased ( P <0.05), the high UDCA dose group decreased more significantly.Western blot results suggest that TGFβ-1 expression in the myocardial tissue was significantly increased compared to the normal group ( P <0.05), whereas low/high UDCA dose group and spironolactone group, TGFβ-1 protein expression were significantly decreased [UDCA(1.52±0.16), (1.02±0.12), (1.01±0.21)vs (2.73±0.12), P <0.05], in which high UDCA dose group TGFβ-1 protein expression level decreased more significantly.However, there was no significant difference in the expression of CTGF, MMP2/9 and TIMP1/4 protein among the groups ( P >0.05). UDCA decrease p-IκB-α expression and increase IκB protein expression dose-dependently. Conclusions: UDCA can relieve isoproterenol induced myocardial fibrosis and reduce the myocardial collagen Ⅰ and collagen Ⅲ deposition in a dose dependent manner.Down-regulating of TGFβ-1 protein expression through the inhibition of TGR5-NF-κB signal transduction pathway might be a potential mechanism underlying UDCA's effects.
Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N
2017-01-01
AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parenica, H; Ford, J; Mavroidis, P
Purpose: To quantify and compare the effect of metallic dental implants (MDI) on dose distributions calculated using Collapsed Cone Convolution Superposition (CCCS) algorithm or a Monte Carlo algorithm (with and without correcting for the density of the MDI). Methods: Seven previously treated patients to the head and neck region were included in this study. The MDI and the streaking artifacts on the CT images were carefully contoured. For each patient a plan was optimized and calculated using the Pinnacle3 treatment planning system (TPS). For each patient two dose calculations were performed, a) with the densities of the MDI and CTmore » artifacts overridden (12 g/cc and 1 g/cc respectively) and b) without density overrides. The plans were then exported to the Monaco TPS and recalculated using Monte Carlo dose calculation algorithm. The changes in dose to PTVs and surrounding Regions of Interest (ROIs) were examined between all plans. Results: The Monte Carlo dose calculation indicated that PTVs received 6% lower dose than the CCCS algorithm predicted. In some cases, the Monte Carlo algorithm indicated that surrounding ROIs received higher dose (up to a factor of 2). Conclusion: Not properly accounting for dental implants can impact both the high dose regions (PTV) and the low dose regions (OAR). This study implies that if MDI and the artifacts are not appropriately contoured and given the correct density, there is potential significant impact on PTV coverage and OAR maximum doses.« less
Isbister, G K; Jayamanne, S; Mohamed, F; Dawson, A H; Maduwage, K; Gawarammana, I; Lalloo, D G; de Silva, H J; Scorgie, F E; Lincz, L F; Buckley, N A
2017-04-01
Essentials Russell's viper envenoming is a major health issue in South Asia and causes coagulopathy. We studied the effect of fresh frozen plasma and two antivenom doses on correcting coagulopathy. Fresh frozen plasma did not hasten recovery of coagulopathy. Low-dose antivenom did not worsen coagulopathy. Background Russell's viper (Daboia russelii) envenoming is a major health issue in South Asia and causes venom-induced consumption coagulopathy (VICC). Objectives To investigate the effects of fresh frozen plasma (FFP) and two antivenom doses in correcting VICC. Methods We undertook an open-label randomized controlled trial in patients with VICC at two Sri Lankan hospitals. Patients with suspected Russell's viper bites and coagulopathy were randomly allocated (1 : 1) to high-dose antivenom (20 vials) or low-dose antivenom (10 vials) plus 4 U of FFP. The primary outcome was the proportion of patients with an International Normalized Ratio (INR) of < 2 at 6 h after antivenom administration. Secondary outcomes included anaphylaxis, major hemorrhage, death, and clotting factor recovery. Results From 214 eligible patients, 141 were randomized: 71 to high-dose antivenom, and 70 to low-dose antivenom/FFP; five had no post-antivenom blood tests. The groups were similar except for a delay of 1 h in antivenom administration for FFP patients. Six hours after antivenom administration, 23 of 69 (33%) patients allocated to high-dose antivenom had an INR of < 2, as compared with 28 of 67 (42%) allocated to low-dose antivenom/FFP (absolute difference 8%; 95% confidence interval - 8% to 25%). Fifteen patients allocated to FFP did not receive it. Severe anaphylaxis occurred equally frequently in each group. One patient given FFP developed transfusion-related acute lung injury. Three deaths occurred in low-dose antivenom/FFP patients, including one intracranial hemorrhage. There was no difference in recovery rates of INR or fibrinogen, but there was more rapid initial recovery of factor V and FX in FFP patients. Conclusion FFP after antivenom administration in patients with Russell's viper bites did not hasten recovery of coagulopathy. Low-dose antivenom/FFP did not worsen VICC, suggesting that low-dose antivenom is sufficient. © 2017 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krayenbuehl, Jerome; Hartmann, Matthias; Lomax, Anthony J.
Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The meanmore » dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unkelbach, J; Perko, Z; Wolfgang, J
Purpose: Stereotactic body radiotherapy (SBRT) has become an established treatment option for liver cancer. For patients with large tumors, the prescription dose is often limited by constraints on the mean liver dose, leading to tumor recurrence. In this work, we demonstrate that spatiotemporal fractionation schemes, ie delivering distinct dose distributions in different fractions, may allow for a 10% increase in biologically effective dose (BED) in the tumor compared to current practice where each fraction delivers the same dose distribution. Methods: We consider rotation therapy delivered with x-ray beams. Treatment plan optimization is performed using objective functions evaluated for the cumulativemore » BED delivered at the end of treatment. This allows for simultaneously optimizing multiple distinct treatment plans for different fractions. Results: The treatment that optimally exploits fractionation effects is designed such that each fraction delivers a similar dose bath to the uninvolved liver while delivering high single fraction doses to complementary parts of the target volume. Thereby, partial hypofractionation in the tumor is achieved along with near uniform fractionation in the surrounding liver - leading to an improvement in the therapeutic ratio. The benefit of such spatiotemporal fractionation schemes depends on tumor geometry and location as well as the number of fractions. For 5-fraction treatments (allowing for 5 distinct dose distributions) an improvement in the order of 10% is observed. Conclusion: Delivering distinct dose distributions in different fractions, purely motivated by fractionation effects rather than geometric changes, may improve the therapeutic ratio. For treatment sites where the prescriptions dose is limited by mean dose constraints in the surrounding organ, such as liver cancer, this approach may facilitate biological dose escalation and improved cure rates.« less
Chen, Lin; Ray, Shonket; Keller, Brad M; Pertuz, Said; McDonald, Elizabeth S; Conant, Emily F; Kontos, Despina
2016-09-01
Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88-0.95; weighted κ = 0.83-0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76-0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density estimation may be feasible. (©) RSNA, 2016 Online supplemental material is available for this article.
2013-01-01
Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158) months, 34 (range: 1–118) months and 29 (range: 1–113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. Trial registration ClinicalTrials.gov number:NCT00978211 PMID:23320604
Response of TLD-100 in mixed fields of photons and electrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawless, Michael J.; Junell, Stephanie; Hammer, Cliff
Purpose: Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. Methods: TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable {sup 60}Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam.more » The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the {sup 60}Co beam. Irradiations were performed in water and in a Virtual Water Trade-Mark-Sign phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. Results: TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. Conclusions: The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.« less
Alqahtani, Saeed A; Alsultan, Abdullah S; Alqattan, Hussain M; Eldemerdash, Ahmed; Albacker, Turki B
2018-04-01
The purpose of this study was to investigate the population pharmacokinetics (PK) of cefuroxime in patients undergoing coronary artery bypass graft (CABG) surgery. In this observational pharmacokinetic study, multiple blood samples were collected over a 48-h interval of intravenous cefuroxime administration. The samples were analyzed by using a validated high-performance liquid chromatography (HPLC) method. Population pharmacokinetic models were developed using Monolix (version 4.4) software. Pharmacokinetic-pharmacodynamic (PD) simulations were performed to explore the ability of different dosage regimens to achieve the pharmacodynamic targets. A total of 468 blood samples from 78 patients were analyzed. The PK for cefuroxime were best described by a two-compartment model with between-subject variability on clearance, the volume of distribution of the central compartment, and the volume of distribution of the peripheral compartment. The clearance of cefuroxime was related to creatinine clearance (CL CR ). Dosing simulations showed that standard dosing regimens of 1.5 g could achieve the PK-PD target of the percentage of the time that the free concentration is maintained above the MIC during a dosing interval ( fT MIC ) of 65% for an MIC of 8 mg/liter in patients with a CL CR of 30, 60, or 90 ml/min, whereas this dosing regimen failed to achieve the PK-PD target in patients with a CL CR of ≥125 ml/min. In conclusion, administration of standard doses of 1.5 g three times daily provided adequate antibiotic prophylaxis in patients undergoing CABG surgery. Lower doses failed to achieve the PK-PD target. Patients with high CL CR values required either higher doses or shorter intervals of cefuroxime dosing. On the other hand, lower doses (1 g three times daily) produced adequate target attainment for patients with low CL CR values (≤30 ml/min). Copyright © 2018 American Society for Microbiology.
Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions
Canonica, Giorgio Walter; Arp, Jan; Keegstra, Johan René
2015-01-01
Abstract Background: Spiromax® is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide–formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and Turbuhaler inhaler) of importance to patients with asthma or COPD. Methods: Dose-delivery studies were performed using low-, middle-, and high-strength DuoResp Spiromax. Dose consistency was assessed over inhaler life. Total emitted doses (TEDs) were measured at various flow rates, after exposure to high and low temperature or humidity, at different inhaler orientations, and after dropping the inhaler. The criterion for evaluating dose uniformity was whether mean TEDs were within the product specification limits. In separate studies, flow rates were measured after training, using the patient information leaflets, and again after enhanced training as part of a randomized, open-label, cross-over study. Results: Mean values for both budesonide and formoterol were within 85%–115% of the label claim for each strength of DuoResp Spiromax for initial dose uniformity and for the other investigated conditions (temperature, humidity, orientation, dropping, knocking), with the exception of approximately an 80% increase in first dose after dropping the inhaler (subsequent doses not affected). In the flow rate patient study, two patients' inhalations with Spiromax and six with Turbuhaler were <30 L/min. The majority of asthma patients [91% (Spiromax) versus 82% (Turbuhaler)] achieved the preferred flow rate of >60 L/min. Conclusions: DuoResp Spiromax consistently meets dose uniformity criteria, under controlled laboratory conditions and with variations intended to mimic real-world use. Following enhanced training, all patients in the flow study were able to achieve the minimal inspiratory flow rate of >30 L/min, which is required for effective treatment. PMID:26352860
SU-F-T-657: In-Room Neutron Dose From High Energy Photon Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christ, D; Ding, G
Purpose: To estimate neutron dose inside the treatment room from photodisintegration events in high energy photon beams using Monte Carlo simulations and experimental measurements. Methods: The Monte Carlo code MCNP6 was used for the simulations. An Eberline ESP-1 Smart Portable Neutron Detector was used to measure neutron dose. A water phantom was centered at isocenter on the treatment couch, and the detector was placed near the phantom. A Varian 2100EX linear accelerator delivered an 18MV open field photon beam to the phantom at 400MU/min, and a camera captured the detector readings. The experimental setup was modeled in the Monte Carlomore » simulation. The source was modeled for two extreme cases: a) hemispherical photon source emitting from the target and b) cone source with an angle of the primary collimator cone. The model includes the target, primary collimator, flattening filter, secondary collimators, water phantom, detector and concrete walls. Energy deposition tallies were measured for neutrons in the detector and for photons at the center of the phantom. Results: For an 18MV beam with an open 10cm by 10cm field and the gantry at 180°, the Monte Carlo simulations predict the neutron dose in the detector to be 0.11% of the photon dose in the water phantom for case a) and 0.01% for case b). The measured neutron dose is 0.04% of the photon dose. Considering the range of neutron dose predicted by Monte Carlo simulations, the calculated results are in good agreement with measurements. Conclusion: We calculated in-room neutron dose by using Monte Carlo techniques, and the predicted neutron dose is confirmed by experimental measurements. If we remodel the source as an electron beam hitting the target for a more accurate representation of the bremsstrahlung fluence, it is feasible that the Monte Carlo simulations can be used to help in shielding designs.« less
Chen, Lin; Ray, Shonket; Keller, Brad M.; Pertuz, Said; McDonald, Elizabeth S.; Conant, Emily F.
2016-01-01
Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88–0.95; weighted κ = 0.83–0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76–0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density estimation may be feasible. © RSNA, 2016 Online supplemental material is available for this article. PMID:27002418
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cervino, L; Soultan, D; Pettersson, N
2016-06-15
Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240more » cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez, Daniel R., E-mail: dgomez@mdanderson.org; Tucker, Susan L.; Martel, Mary K.
2012-11-15
Introduction: We analyzed the ability of various patient- and treatment-related factors to predict radiation-induced esophagitis (RE) in patients with non-small cell lung cancer (NSCLC) treated with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or proton beam therapy (PBT). Methods and Materials: Patients were treated for NSCLC with 3D-CRT, IMRT, or PBT at MD Anderson from 2000 to 2008 and had full dose-volume histogram (DVH) data available. The endpoint was severe (grade {>=}3) RE. The Lyman-Kutcher-Burman (LKB) model was used to analyze RE as a function of the fractional esophageal DVH, with clinical variables included as dose-modifying factors. Results:more » Overall, 652 patients were included: 405 patients were treated with 3D-CRT, 139 with IMRT, and 108 with PBT; corresponding rates of grade {>=}3 RE were 8%, 28%, and 6%, respectively, with a median time to onset of 42 days (range, 11-93 days). A fit of the fractional DVH LKB model demonstrated that the fractional effective dose was significantly different (P=.046) than 1 (fractional mean dose) indicating that high doses to small volumes are more predictive than mean esophageal dose. The model fit was better for 3D-CRT and PBT than for IMRT. Including receipt of concurrent chemotherapy as a dose-modifying factor significantly improved the LKB model (P=.005), and the model was further improved by including a variable representing treatment with >30 fractions. Examining individual types of chemotherapy agents revealed a trend toward receipt of concurrent taxanes and increased risk of RE (P=.105). Conclusions: Fractional dose (dose rate) and number of fractions (total dose) distinctly affect the risk of severe RE, estimated using the LKB model, and concurrent chemotherapy improves the model fit. This risk of severe RE is underestimated by this model in patients receiving IMRT.« less
Melchert, Corinna; Kovács, György
2016-01-01
Purpose This study aims to compare the dosimetric data of local tumor's bed dose escalation (boost) with photon beams (external beam radiation therapy – EBRT) versus high-dose-rate interstitial brachytherapy (HDR-BT) after breast-conserving treatment in women with early-stage breast cancer. Material and methods We analyzed the treatment planning data of 136 irradiated patients, treated between 2006 and 2013, who underwent breast-conserving surgery and adjuvant whole breast irradiation (WBI; 50.4 Gy) and boost (HDR-BT: 10 Gy in one fraction [n = 36]; EBRT: 10 Gy in five fractions [n = 100]). Organs at risk (OAR; heart, ipsilateral lung, skin, most exposed rib segment) were delineated. Dosimetric parameters were calculated with the aid of dose-volume histograms (DVH). A non-parametric test was performed to compare the two different boost forms. Results There was no difference for left-sided cancers regarding the maximum dose to the heart (HDR-BT 29.8% vs. EBRT 29.95%, p = 0.34). The maximum doses to the other OAR were significantly lower for HDR-BT (Dmax lung 47.12% vs. 87.7%, p < 0.01; rib 61.17% vs. 98.5%, p < 0.01; skin 57.1% vs. 94.75%, p < 0.01; in the case of right-sided breast irradiation, dose of the heart 6.00% vs. 16.75%, p < 0.01). Conclusions Compared to EBRT, local dose escalation with HDR-BT presented a significant dose reduction to the investigated OAR. Only left-sided irradiation showed no difference regarding the maximum dose to the heart. Reducing irradiation exposure to OAR could result in a reduction of long-term side effects. Therefore, from a dosimetric point of view, an interstitial boost complementary to WBI via EBRT seems to be more advantageous in the adjuvant radiotherapy of breast cancer. PMID:27648082
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Linda X.; Garg, Madhur; Lasala, Patrick
2011-03-15
Purpose: Sharp dose fall off outside a tumor is essential for high dose single fraction stereotactic radiosurgery (SRS) plans. This study explores the relationship among tumor dose inhomogeneity, conformity, and dose fall off in normal tissues for micromultileaf collimator (mMLC) linear accelerator (LINAC) based cranial SRS plans. Methods: Between January 2007 and July 2009, 65 patients with single cranial lesions were treated with LINAC-based SRS. Among them, tumors had maximum diameters {<=}20 mm: 31; between 20 and 30 mm: 21; and >30 mm: 13. All patients were treated with 6 MV photons on a Trilogy linear accelerator (Varian Medical Systems,more » Palo Alto, CA) with a tertiary m3 high-resolution mMLC (Brainlab, Feldkirchen, Germany), using either noncoplanar conformal fixed fields or dynamic conformal arcs. The authors also created retrospective study plans with identical beam arrangement as the treated plan but with different tumor dose inhomogeneity by varying the beam margins around the planning target volume (PTV). All retrospective study plans were normalized so that the minimum PTV dose was the prescription dose (PD). Isocenter dose, mean PTV dose, RTOG conformity index (CI), RTOG homogeneity index (HI), dose gradient index R{sub 50}-R{sub 100} (defined as the difference between equivalent sphere radius of 50% isodose volume and prescription isodose volume), and normal tissue volume (as a ratio to PTV volume) receiving 50% prescription dose (NTV{sub 50}) were calculated. Results: HI was inversely related to the beam margins around the PTV. CI had a ''V'' shaped relationship with HI, reaching a minimum when HI was approximately 1.3. Isocenter dose and mean PTV dose (as percentage of PD) increased linearly with HI. R{sub 50}-R{sub 100} and NTV{sub 50} initially declined with HI and then reached a plateau when HI was approximately 1.3. These trends also held when tumors were grouped according to their maximum diameters. The smallest tumor group (maximum diameters {<=}20 mm) had the most HI dependence for dose fall off. For treated plans, CI averaged 2.55{+-}0.79 with HI 1.23{+-}0.06; the average R{sub 50}-R{sub 100} was 0.41{+-}0.08, 0.55{+-}0.10, and 0.65{+-}0.09 cm, respectively, for tumors {<=}20 mm, between 20 and 30 mm, and >30 mm. Conclusions: Tumor dose inhomogeneity can be used as an important and convenient parameter to evaluate mMLC LINAC-based SRS plans. Sharp dose fall off in the normal tissue is achieved with sufficiently high tumor dose inhomogeneity. By adjusting beam margins, a homogeneity index of approximately 1.3 would provide best conformity for the authors' SRS system.« less
Ren, Wenkai; Liu, Shuping; Chen, Shuai; Zhang, Fengmei; Li, Nengzhang; Yin, Jie; Peng, Yuanyi; Wu, Li; Liu, Gang; Yin, Yulong; Wu, Guoyao
2013-10-01
This study was conducted to determine the effects of graded doses of L-glutamine supplementation on the replication and distribution of Pasteurella multocida, and the expression of its major virulence factors in mouse model. Mice were randomly assigned to the basal diet supplemented with 0, 0.5, 1.0 or 2.0 % glutamine. Pasteurella multocida burden was detected in the heart, liver, spleen, lung and kidney after 12 h of P. multocida infection. The expression of major virulence factors, toll-like receptors (TLRs), proinflammatory cytokines (interleukin-1 beta, interleukin-6, and tumor necrosis factor alpha) and anti-oxidative factors (GPX1 and CuZnSOD) was analyzed in the lung and spleen. Dietary 0.5 % glutamine supplementation has little significant effect on these parameters, compared to those with basal diet. However, results showed that a high dose of glutamine supplementation increased the P. multocida burden (P < 0.001) and the expression of its major virulence factors (P < 0.05) as compared to those with a lower dose of supplementation. In the lung, high dose of glutamine supplementation inhibited the proinflammatory responses (P < 0.05) and TLRs signaling (P < 0.05). In the spleen, the effect of glutamine supplementation on different components in TLR signaling depends on glutamine concentration, and high dose of glutamine supplementation activated the proinflammatory response. In conclusion, glutamine supplementation increased P. multocida burden and the expression of its major virulence factors, while affecting the functions of the lung and spleen.
Wheaton, Catharine J; Joseph, Sharon; Reid, Kelly; Webster, Tricia; Richards, Mary; Forde, Holly M; Savage, Anne
2007-07-01
Analysis of fecal progestogen profiles during Depo-Provera injection (1,200 mg; DEPO, Pfizer Inc., New York, NY), melengestrol acetate (MGA) in feed (2 or 3 mg/head/day), and a combination treatment (DEPO+MGA) are presented for nine captive female Nile hippos housed at Disney's Animal Kingdom in Florida. All tested treatments reduced fecal progestogen elevations successfully to durations consistent with prevention of ovulation for a portion of the treatment period. Percentage of treatment months with suppression of luteal phases indicative of ovulation was maximal for high-dose MGA (91.7+/-13.9%) and DEPO+MGA (91.7+/-20.4%), followed by DEPO injection alone (69.2+/-13.9%) and low-dose MGA (57.6+/-33.2%). Both 1,200 mg DEPO and low-dose MGA (2.0 mg/day) treatments were insufficient to prevent an apparent seasonal breakthrough of ovarian activity from June-August 2002. Although luteal phases were observed, no females conceived during those months. Overall, in 133.5 treatment months with females housed with an adult male, one female conceived during the transition period between treatments. After cessation of contraceptive treatment, average latency to first normal ovarian cycle was 80.6+/-19.5 days (range = 22-179 days). Up to 12 months post-treatment, however, successive cycles were often irregular with evidence of short periods of anovulation and shortened luteal phases in all females monitored. In conclusion, high dose and combination treatments were most successful in preventing progestogen increases indicative of ovulation in hippos. Zoo Biol 26:259-274, 2007. (c) 2007 Wiley-Liss, Inc.
Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Susan, E-mail: srichardson@radonc.wustl.ed; Palaniswaamy, Geethpriya; Grigsby, Perry W.
2010-09-01
Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction.more » The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm{sup 3} (range, 0.01-1.32 cm{sup 3}). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.« less
Scharf, Valery F; Farese, James P; Coomer, Alastair R; Milner, Rowan J; Taylor, David P; Salute, Marc E; Chang, Myron N; Neal, Dan; Siemann, Dietmar W
2013-05-01
Objective-To investigate the effects of bevacizumab, a human monoclonal antibody against vascular endothelial growth factor, on the angiogenesis and growth of canine osteosarcoma cells xenografted in mice. Animals-27 athymic nude mice. Procedures-To each mouse, highly metastasizing parent osteosarcoma cells of canine origin were injected into the left gastrocnemius muscle. Each mouse was then randomly allocated to 1 of 3 treatment groups: high-dose bevacizumab (4 mg/kg, IP), low-dose bevacizumab (2 mg/kg, IP), or control (no treatment). Tumor growth (the number of days required for the tumor to grow from 8 to 13 mm), vasculature, histomorphology, necrosis, and pulmonary metastasis were evaluated. Results-Mice in the high-dose bevacizumab group had significantly delayed tumor growth (mean ± SD, 13.4 ± 3.8 days; range, 9 to 21 days), compared with that for mice in the low-dose bevacizumab group (mean ± SD, 9.4 ± 1.5 days; range, 7 to 11 days) or control group (mean ± SD, 7. 2 ± 1.5 days; range, 4 to 9 days). Mice in the low-dose bevacizumab group also had significantly delayed tumor growth, compared with that for mice in the control group. Conclusions and Clinical Relevance-Results indicated that bevacizumab inhibited growth of canine osteosarcoma cells xenografted in mice, which suggested that vascular endothelial growth factor inhibitors may be clinically useful for the treatment of osteosarcoma in dogs. Impact for Human Medicine-Canine osteosarcoma is used as a research model for human osteosarcoma; therefore, bevacizumab may be clinically beneficial for the treatment of osteosarcoma in humans.
The effective dose result of 18F-FDG PET-CT paediatric patients
NASA Astrophysics Data System (ADS)
Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.
2017-05-01
Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.
Standard and Nonstandard Craniospinal Radiotherapy Using Helical TomoTherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, William, E-mail: william@medphys.mcgill.c; Brodeur, Marylene; Roberge, David
2010-07-01
Purpose: To show the advantages of planning and delivering craniospinal radiotherapy with helical TomoTherapy (TomoTherapy Inc., Madison, WI) by presenting 4 cases treated at our institution. Methods and Materials: We first present a standard case of craniospinal irradiation in a patient with recurrent myxopapillary ependymoma (MPE) and follow this with 2 cases requiring differential dosing to multiple target volumes. One of these, a patient with recurrent medulloblastoma, required a lower dose to be delivered to the posterior fossa because the patient had been previously irradiated to the full dose, and the other required concurrent boosts to leptomeningeal metastases as partmore » of his treatment for newly diagnosed MPE. The final case presented is a patient with pronounced scoliosis who required spinal irradiation for recurrent MPE. Results: The four cases presented were planned and treated successfully with Helical Tomotherapy. Conclusions: Helical TomoTherapy delivers continuous arc-based intensity-modulated radiotherapy that gives high conformality and excellent dose homogeneity for the target volumes. Increased healthy tissue sparing is achieved at higher doses albeit at the expense of larger volumes of tissue receiving lower doses. Helical TomoTherapy allows for differential dosing of multiple targets, resulting in very elegant dose distributions. Daily megavoltage computed tomography imaging allows for precision of patient positioning, permitting a reduction in planning margins and increased healthy tissue sparing in comparison with standard techniques.« less
Ozgen, Aytul; Hayran, Mutlu; Kahraman, Fatih
2012-11-01
The intention of this research was to define the predictive factors for acute esophagitis (AE) in lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy. The data for 72 lung cancer patients treated with concurrent chemoradiotherapy between 2008 and 2010 were prospectively evaluated. Mean lung dose, mean dose of esophagus, volume of esophagus irradiated and percentage of esophagus volume treated were analysed according to esophagitis grades. The mean esophageal dose was associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P < 0.001). However, the mean lung dose and the volume of esophagus irradiated were not associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P = 0.50 and P = 0.41, respectively). The mean radiation dose received by the esophagus was found to be highly correlated with the duration of Grade 2 esophagitis (Spearman test, r = 0.82, P < 0.001). The mean dose of esophagus ≥28 Gy showed statistical significance with respect to AE Grade 2 or worse (receiver operating characteristic curve analysis, 95% CI, 0.929-1.014). In conclusion, the mean esophageal dose was significantly associated with a risk of esophageal toxicity in patients with lung cancer treated with concurrent radiotherapy and chemotherapy.
Ozgen, Aytul; Hayran, Mutlu; Kahraman, Fatih
2012-01-01
The intention of this research was to define the predictive factors for acute esophagitis (AE) in lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy. The data for 72 lung cancer patients treated with concurrent chemoradiotherapy between 2008 and 2010 were prospectively evaluated. Mean lung dose, mean dose of esophagus, volume of esophagus irradiated and percentage of esophagus volume treated were analysed according to esophagitis grades. The mean esophageal dose was associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P < 0.001). However, the mean lung dose and the volume of esophagus irradiated were not associated with an increased risk of esophageal toxicity (Kruskal-Wallis test, P = 0.50 and P = 0.41, respectively). The mean radiation dose received by the esophagus was found to be highly correlated with the duration of Grade 2 esophagitis (Spearman test, r = 0.82, P < 0.001). The mean dose of esophagus ≥28 Gy showed statistical significance with respect to AE Grade 2 or worse (receiver operating characteristic curve analysis, 95% CI, 0.929–1.014). In conclusion, the mean esophageal dose was significantly associated with a risk of esophageal toxicity in patients with lung cancer treated with concurrent radiotherapy and chemotherapy. PMID:22915782
Zee, Jarcy; Morgenstern, Hal; Nolen, Jacqueline G.; Hakim, Raymond; Kalantar-Zadeh, Kamyar; Zager, Philip; Pisoni, Ronald L.; Port, Friedrich K.; Robinson, Bruce M.
2015-01-01
Background and objectives Anemia management changed substantially among dialysis patients in the United States around the time of implementation of the new Centers for Medicare & Medicaid Services bundled payment system and erythropoiesis-stimulating agent (ESA) label change in 2011. Among these, average ferritin levels increased dramatically and have remained high since; this study sought to gain understanding of this sustained rise in ferritin levels. Design, setting, participants, & measurements Trends in mean ferritin, hemoglobin, IV iron dose, and ESA dose from 2009 to 2013 were examined in 9735 patients from 91 United States Dialysis Outcomes and Practice Patterns Study facilities. Linear mixed models were used to assess the extent to which intravenous (IV) iron and ESA dose accounted for patients’ changes in ferritin over time. Results Mean ESA dose and hemoglobin levels declined throughout the study. Mean IV iron dose increased from 210 mg/mo in 2009–2010 to a peak of 280 mg/mo in 2011, then declined back to 200 mg/mo and remained stable from 2012 to 2013. Mean ferritin increased from 601 ng/ml in the third quarter of 2009 to 887 ng/ml in the first quarter of 2012; models suggest that higher IV iron dosing was a primary determinant during 2011, but lower ESA doses contributed to the sustained high ferritin levels thereafter. In a subset of 17 facilities that decreased IV iron dose in 2011, mean ferritin rose by 120 ng/ml to 764 ng/ml, which appeared to be primarily due to ESA reduction. Together, changes in IV iron and ESA doses accounted for 46% of the increase in ferritin over the study period. Conclusions In contrast to expectations, the rise in average IV iron dose did not persist beyond 2011. The sustained rise in ferritin levels in United States dialysis patients after policy changes in 2011, to average levels well in excess of 800 ng/ml, appeared to be partly due to reductions in ESA dosing and not solely IV iron dosing practices. The effect of these changes in ferritin on health outcomes requires further investigation. PMID:26286925
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wernicke, A. Gabriella; Valicenti, Richard; DiEva, Kelly
2004-12-01
Purpose/objective: In this study, we evaluated in a serial manner whether radiation dose to the bulb of the penis is predictive of erectile dysfunction, ejaculatory difficulty (EJ), and overall satisfaction with sex life (quality of life) by using serial validated self-administered questionnaires. Methods and materials: Twenty-nine potent men with AJCC Stage II prostate cancer treated with three-dimensional conformal radiation therapy alone to a median dose 72.0 Gy (range: 66.6-79.2 Gy) were evaluated by determining the doses received by the penile bulb. The penile bulb was delineated volumetrically, and the dose-volume histogram was obtained on each patient. Results: The median follow-upmore » time was 35 months (range, 16-43 months). We found that for D{sub 30}, D{sub 45}, D{sub 60}, and D{sub 75} (doses to a percent volume of PB: 30%, 45%, 60%, and 75%), higher than the corresponding median dose (defined as high-dose group) correlated with an increased risk of impotence (erectile dysfunction firmness score = 0) (odds ratio [OR] = 7.5, p = 0.02; OR = 7.5, p = 0.02; OR = 8.6, p = 0.008; and OR = 6.9, p = 0.015, respectively). Similarly, for EJD D{sub 30}, D{sub 45}, D{sub 60}, and D{sub 75}, doses higher than the corresponding median ones correlated with worsening ejaculatory function score (EJ = 0 or 1) (OR = 8, p = 0.013; OR = 8, p 0.013; OR = 9.2, p = 0.015; and OR = 8, p = 0.026, respectively). For quality of life, low ({<=}median dose) dose groups of patients improve over time, whereas high-dose groups of patients worsen. Conclusions: This study supports the existence of a penile bulb dose-volume relationship underlying the development of radiation-induced erectile dysfunction. Our data may guide the use of inverse treatment planning to maximize the probability of maintaining sexual potency after radiation therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niewald, Marcus, E-mail: marcus.niewald@uks.eu; Seegenschmiedt, M. Heinrich; Micke, Oliver
2012-11-15
Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey.more » The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, S; Keeling, V; Ahmad, S
Purpose: To determine the effects of multileaf collimator (MLC) leaf width on normal-brain-tissue doses and dose conformity of SRS RapidArc treatment plans for brain tumors. Methods: Ten patients with 24 intracranial tumors (seven with 1–2 and three with 4–6 lesions) were planned using RapidArc for both Varian Millennium 120 MLC (5 mm leaf width) and high definition (HD) MLC (2.5 mm leaf width). Between 2 and 8 arcs were used with two full coplanar arcs and the rest non-coplanar half arcs. 6 MV beams were used and plans were optimized with a high priority to the Normal Tissue Objective (tomore » achieve dose conformity and sharp dose fall-off) and normal brain tissue. Calculation was done using AAA on a 1 mm grid size. The prescription dose ranged from 14–22 Gy. Plans were normalized such that 99% of the target received the prescription dose. Identical beam geometries, optimizations, calculations, and normalizations were used for both plans. Paddick Conformity Index (PCI), V4, V8 and V12 Gy for normal brain tissue and Integral Dose were used for analysis. Results: In all cases, HD MLC plans performed better in sparing normal brain tissue, achieving a higher PCI with a lower Integral Dose. The average PCI for all 24 targets was 0.75±0.23 and 0.70±0.23 (p ≤0.0015) for HD MLC and Millennium MLC plans, respectively. The average ratio of normal brain doses for Millennium MLC to HD MLC plans was 1.30±0.16, 1.27±0.15, and 1.31±0.18 for the V4, V8, and V12, respectively. The differences in normal brain dose for all criteria were statistically significant with p-value < 0.02. On average Millennium MLC plans had a 16% higher integral dose than HD MLC plans. Conclusion: Significantly better dose conformity with reduced volume of normal brain tissue and integral dose was achieved with HD MLC plans compared to Millennium MLC plans.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Felix Y., E-mail: ffeng@med.umich.edu; Department of Radiation Oncology, Veterans Affairs Medical Center, Ann Arbor, Michigan; Blas, Kevin
2013-05-01
Purpose: To evaluate the role of androgen deprivation therapy (ADT) and duration for high-risk prostate cancer patients treated with dose-escalated radiation therapy (RT). Methods and Materials: A retrospective analysis of high-risk prostate cancer patients treated with dose-escalated RT (minimum 75 Gy) with or without ADT was performed. The relationship between ADT use and duration with biochemical failure (BF), metastatic failure (MF), prostate cancer-specific mortality (PCSM), non-prostate cancer death (NPCD), and overall survival (OS) was assessed as a function of pretreatment characteristics, comorbid medical illness, and treatment using Fine and Gray's cumulative incidence methodology. Results: The median follow-up time was 64more » months. In men with National Comprehensive Cancer Network defined high-risk prostate cancer treated with dose-escalated RT, on univariate analysis, both metastasis (P<.0001; hazard ratio 0.34; 95% confidence interval 0.18-0.67; cumulative incidence at 60 months 13% vs 35%) and PCSM (P=.015; hazard ratio 0.41; 95% confidence interval 0.2-1.0; cumulative incidence at 60 months 6% vs 11%) were improved with the use of ADT. On multivariate analysis for all high-risk patients, Gleason score was the strongest negative prognostic factor, and long-term ADT (LTAD) improved MF (P=.002), PCSM (P=.034), and OS (P=.001). In men with prostate cancer and Gleason scores 8 to 10, on multivariate analysis after adjustment for other risk features, there was a duration-dependent improvement in BF, metastasis, PCSM, and OS, all favoring LTAD in comparison with STAD or RT alone. Conclusion: For men with high-risk prostate cancer treated with dose-escalated EBRT, this retrospective study suggests that the combination of LTAD and RT provided a significant improvement in clinical outcome, which was especially true for those with Gleason scores of 8 to 10.« less
2012-01-01
Background Divergent strategies have emerged for the management of severe asthma. One strategy utilises high and fixed doses of maintenance treatment, usually inhaled corticosteroid/long-acting β2-agonist (ICS/LABA), supplemented by a short-acting β2-agonist (SABA) as needed. Alternatively, budesonide/formoterol is used as both maintenance and reliever therapy. The latter is superior to fixed-dose treatment in reducing severe exacerbations while achieving similar or better asthma control in other regards. Exacerbations may be reduced by the use of budesonide/formoterol as reliever medication during periods of unstable asthma. We examined the risk of a severe exacerbation in the period after a single day with high reliever use. Methods Episodes of high reliever use were quantified and exacerbations occurring post-index day with these episodes were examined post hoc in two double-blind studies comparing the efficacy and safety of budesonide/formoterol maintenance and reliever therapy (Symbicort SMART™, Turbuhaler®) 160/4.5 μg twice daily plus as needed with similar or higher maintenance doses of ICS/LABA plus SABA or formoterol. Results Budesonide/formoterol maintenance and reliever therapy significantly reduced the risk of episodes of high reliever use (>6 inhalations/day) vs. all alternative ICS/LABA regimens. With conventional fixed-dose treatment the need for exacerbation treatment within 21 days ranged from 6.0–10.1% of days post-index for all regimens compared with 2.5–3.4% of days with budesonide/formoterol maintenance and reliever therapy. Conclusions Budesonide/formoterol maintenance and reliever therapy reduces the incidence of high reliever episodes and the exacerbation burden immediately following these episodes vs. alternative ICS/LABA plus SABA regimens at up to double the maintenance dose of ICS. Trial registration These studies do not have registration numbers as they were conducted before clinical trial registration was required PMID:22816878
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Y; Lacroix, F; Lavallee, M
Purpose: To evaluate the commercially released Collapsed Cone convolution-based(CCC) dose calculation module of the Elekta OncentraBrachy(OcB) treatment planning system(TPS). Methods: An allwater phantom was used to perform TG43 benchmarks with single source and seventeen sources, separately. Furthermore, four real-patient heterogeneous geometries (chestwall, lung, breast and prostate) were used. They were selected based on their clinical representativity of a class of clinical anatomies that pose clear challenges. The plans were used as is(no modification). For each case, TG43 and CCC calculations were performed in the OcB TPS, with TG186-recommended materials properly assigned to ROIs. For comparison, Monte Carlo simulation was runmore » for each case with the same material scheme and grid mesh as TPS calculations. Both modes of CCC (standard and high quality) were tested. Results: For the benchmark case, the CCC dose, when divided by that of TG43, yields hot-n-cold spots in a radial pattern. The pattern of the high mode is denser than that of the standard mode and is representative of angular dicretization. The total deviation ((hot-cold)/TG43) is 18% for standard mode and 11% for high mode. Seventeen dwell positions help to reduce “ray-effect”, with the total deviation to 6% (standard) and 5% (high), respectively. For the four patient cases, CCC produces, as expected, more realistic dose distributions than TG43. A close agreement was observed between CCC and MC for all isodose lines, from 20% and up; the 10% isodose line of CCC appears shifted compared to that of MC. The DVH plots show dose deviations of CCC from MC in small volume, high dose regions (>100% isodose). For patient cases, the difference between standard and high modes is almost undiscernable. Conclusion: OncentraBrachy CCC algorithm marks a significant dosimetry improvement relative to TG43 in real-patient cases. Further researches are recommended regarding the clinical implications of the above observations. Support provided by a CIHR grant and CCC system provided by Elekta-Nucletron.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sung, Wonmo; Kim, Siyong; Kim, Jung-in
2012-10-15
Purpose: To investigate dose perturbations for pacemaker-implanted patients in partial breast irradiation using high dose rate (HDR) balloon brachytherapy. Methods: Monte Carlo (MC) simulations were performed to calculate dose distributions involving a pacemaker in Ir-192 HDR balloon brachytherapy. Dose perturbations by varying balloon-to-pacemaker distances (BPD = 50 or 100 mm) and concentrations of iodine contrast medium (2.5%, 5.0%, 7.5%, and 10.0% by volume) in the balloon were investigated for separate parts of the pacemaker (i.e., battery and substrate). Relative measurements using an ion-chamber were also performed to confirm MC results. Results: The MC and measured results in homogeneous media withoutmore » a pacemaker agreed with published data within 2% from the balloon surface to 100 mm BPD. Further their dose distributions with a pacemaker were in a comparable agreement. The MC results showed that doses over the battery were increased by a factor of 3, compared to doses without a pacemaker. However, there was no significant dose perturbation in the middle of substrate but up to 70% dose increase in the substrate interface with the titanium capsule. The attenuation by iodine contrast medium lessened doses delivered to the pacemaker by up to 9%. Conclusions: Due to inhomogeneity of pacemaker and contrast medium as well as low-energy photons in Ir-192 HDR balloon brachytherapy, the actual dose received in a pacemaker is different from the homogeneous medium-based dose and the external beam-based dose. Therefore, the dose perturbations should be considered for pacemaker-implanted patients when evaluating a safe clinical distance between the balloon and pacemaker.« less
Snajderova, Marta; Blair, Jo; Pournara, Effie; Pedersen, Birgitte Tønnes; Petit, Isabelle Oliver
2017-01-01
Objective To describe real-life dosing patterns in children with growth hormone deficiency (GHD), born small for gestational age (SGA) or with Turner syndrome (TS) receiving growth hormone (GH) and enrolled in the NordiNet International Outcome Study (IOS; Nbib960128) between 2006 and 2016. Design This non-interventional, multicentre study included paediatric patients diagnosed with GHD (isolated (IGHD) or multiple pituitary hormone deficiency (MPHD)), born SGA or with TS and treated according to everyday clinical practice from the Czech Republic (IGHD/MPHD/SGA/TS: n = 425/61/316/119), France (n = 1404/188/970/206), Germany (n = 2603/351/1387/411) and the UK (n = 259/60/87/35). Methods GH dosing was compared descriptively across countries and indications. Proportions of patients by GH dose group (low/medium/high) or GH dose change (decrease/increase/no change) during years 1 and 2 were also evaluated across countries and indications. Results In the Czech Republic, GH dosing was generally within recommended levels. In France, average GH doses were higher for patients with IGHD, MPHD and SGA than in other countries. GH doses in TS tended to be at the lower end of the recommended label range, especially in Germany and the UK; the majority of patients were in the low-dose group. A significant inverse association between baseline height standard deviation score and GH dose was shown (P < 0.05); shorter patients received higher doses. Changes in GH dose, particularly increases, were more common in the second (40%) than in the first year (25%). Conclusions GH dosing varies considerably across countries and indications. In particular, almost half of girls with TS received GH doses below practice guidelines and label recommendations. PMID:28522645
Brooks, Antone L.; Hoel, David G.; Preston, R. Julian
2016-01-01
Abstract Purpose: This review evaluates the role of dose rate on cell and molecular responses. It focuses on the influence of dose rate on key events in critical pathways in the development of cancer. This approach is similar to that used by the U.S. EPA and others to evaluate risk from chemicals. It provides a mechanistic method to account for the influence of the dose rate from low-LET radiation, especially in the low-dose region on cancer risk assessment. Molecular, cellular, and tissues changes are observed in many key events and change as a function of dose rate. The magnitude and direction of change can be used to help establish an appropriate dose rate effectiveness factor (DREF). Conclusions: Extensive data on key events suggest that exposure to low dose-rates are less effective in producing changes than high dose rates. Most of these data at the molecular and cellular level support a large (2–30) DREF. In addition, some evidence suggests that doses delivered at a low dose rate decrease damage to levels below that observed in the controls. However, there are some data human and mechanistic data that support a dose-rate effectiveness factor of 1. In summary, a review of the available molecular, cellular and tissue data indicates that not only is dose rate an important variable in understanding radiation risk but it also supports the selection of a DREF greater than one as currently recommended by ICRP (2007) and BEIR VII (NRC/NAS 2006). PMID:27266588
Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil*
da Silva, Rogério Matias Vidal; Pinezi, Juliana Castro Dourado; Macedo, Luiz Eduardo Andrade; Souza, Divanízia do Nascimento
2014-01-01
Objective To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and Methods In the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results Sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion The authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. PMID:25741073
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-Rovira, I., E-mail: immamartinez@gmail.com; Prezado, Y.; Fois, G.
Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Montemore » Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.« less
Bus, James S
2015-12-01
The non-peer-reviewed biomonitoring report published online by Moms Across America (MAA; Honeycutt and Rowlands, 2014) does not support the conclusion that glyphosate concentrations detected in a limited number of urine samples from women, men and children, or breast milk from nursing mothers, pose a health risk to the public, including nursing children. Systemically absorbed doses of glyphosate estimated from the MAA urine biomonitoring data and from other published biomonitoring studies indicate that daily glyphosate doses are substantially below health protective reference standards (ADIs; RfDs) established by regulatory agencies. The MAA report also suggested that detection of relatively high glyphosate concentrations in breast milk in 3 of 10 sampled women raised a concern for bioaccumulation in breast milk. However, the breast milk concentrations reported by MAA are highly implausible when considered in context to low daily systemic doses of glyphosate estimated from human urine biomonitoring data, and also are inconsistent with animal toxicokinetic data demonstrating no evidence of retention in tissues or milk after single- or multiple-dose glyphosate treatment. In addition, toxicokinetic studies in lactating goats have shown that glyphosate does not partition into milk at concentrations greater than blood, and that only a very small percentage of the total administered dose (<0.03%) is ultimately excreted into milk. The toxicokinetic studies also indicate that human glyphosate exposures estimated from urine biomonitoring fall thousands-of-fold short of external doses capable of producing blood concentrations sufficient to result in the breast milk concentrations described in the MAA report. Finally, in contrast to highly lipophilic compounds with bioaccumulation potential in breast milk, the physico-chemical properties of glyphosate indicate that it is highly hydrophilic (ionized) at physiological pH and unlikely to preferentially distribute into breast milk. Copyright © 2015 Elsevier Inc. All rights reserved.
Ateş, Gökay; Yaman, Ferda; Bakar, Bülent; Kısa, Üçler; Atasoy, Pınar; Büyükkoçak, Ünase
2017-09-01
Blunt thoracic injury often leads to pulmonary contusion and the development of acute respiratory distress syndrome, which carries a high risk of morbidity and mortality, originating from the local and systemic inflammatory states. This study aimed to investigate the local and systemic antiinflammatory effects of levosimendan in rat models of blunt chest trauma. A total of 32 Wistar albino rats were randomly assigned to one of the following four groups: control, sham, low-dose levosimendan (LDL) (5 µg/kg loading dose for 10 min and 0.05 µg/kg/min intravenous infusion), and high-dose levosimendan (HDL) (10 µg/kg loading dose for 10 min and 0.1 µg/kg/min intravenous infusion). Blunt chest trauma was induced, and after 6 h, the contused pulmonary tissues were histopathologically and immunohistopathologically evaluated, serum TNF-α, IL-1ß, IL-6, and NO levels were biochemically evaluated. The mean arterial pressure was low throughout the experiment in the LDL and HDL groups, with no statistically difference between the groups. Levosimendan reduced the alveolar congestion and hemorrhage, which developed after inducing trauma. Neutrophil infiltration to the damaged pulmonary tissue was also reduced in both the LDL and HDL groups. In rats in which pulmonary contusion (PC) was observed, increased activation of nuclear factor kappa B was observed in the pulmonary tissue, and levosimendan did not reduce this activation. Both high and low doses of levosimendan reduced serum IL-1ß levels, and high doses of levosimendan reduced IL-6 and NO levels. TNF-α levels were not reduced. In conclusion, the results showed that in a rat model of PC, the experimental agent levosimendan could reduce neutrophil cell infiltration to damaged pulmonary tissues and the systemic expressions of some cytokines (IL-1ß, IL-6, and NO), thereby partially reducing and/or correcting pulmonary damage. Systemic inflammatory response that occurs after trauma could also be reduced.
Long, Lina; Chen, Jiashun; Zhang, Yonggang; Liang, Xiao
2017-01-01
The aim of this study was to compare the effect of dietary supplementation with low dose of porous and nano zinc oxide (ZnO) on weaning piglets, and to evaluate the possibility of using them as an alternative to high dose of regular ZnO. Piglets were randomly allocated into four treatment groups fed with four diets: (1) basal diet (NC), (2) NC+ 3000 mg/kg ZnO (PC), (3) NC + 500 mg/kg porous ZnO (HiZ) and (4) NC + 500 mg/kg nano ZnO (ZNP). The result showed that piglets in HiZ group had less diarrhea than ZNP group (P < 0.05). Besides, there was no significant difference between PC, HiZ and ZNP groups in terms of serum malondialdeyhde (MDA) concentration and glutathione peroxidase (GSH-Px) activity (P > 0.05). Analysis of trace metal elements revealed that piglets fed with high dose of regular ZnO had the highest Zn level in kidney (P < 0.05), which may induce kidney stone formation. Additionally, a decrease in ileal crypt depth was observed in PC, HiZ and ZNP group, suggesting an effective protection against intestinal injury. Results of mRNA analysis in intestine showed that ZNP supplementation had better effects on up-regulated trefoil factor 3 (TFF3) and nuclear factor erythroid 2-related factor 2 (Nrf2) levels in duodenum and jejunum than HiZ did (P < 0.05), implying that nano ZnO may possess higher anti-inflammatory capacity than porous ZnO. In conclusion, dietary supplementation with low dose of porous and nano ZnO had similar (even better) effect on improving growth performance and intestinal morphology, reducing diarrhea and intestinal inflammatory as high dose of regular ZnO in weaning piglets. Compared with nano ZnO, porous ZnO had better performance on reducing diarrhea but less effect on up-regulation of intestinal TFF3 and Nrf2. PMID:28792520
Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.
2016-01-01
Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria. PMID:27936077
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Trovati, S; Loo, B
Purpose: To study the impact of electron beam size, target thickness, and target temperature on the ability of the flattening filter-free mode (FFF) treatment head to deliver high-dose-rate irradiations. Methods: The dose distribution and transient temperature of the X-ray target under 10 MeV electron beam with pulse length of 5 microseconds, and repetition rate of 1000 Hz was studied. A MCNP model was built to calculate the percentage depth dose (PPD) distribution in a water phantom at a distance of 100 cm. ANSYS software was used to run heat transfer simulations. The PPD and temperature for both tungsten and W25Remore » targets for different electron beam sizes (FHWM 0.2, 0.5, 1 and 2 mm) and target thickness (0.2 to 2 mm) were studied. Results: Decreasing the target thickness from 1 mm to 0.5 mm, caused a surface dose increase about 10 percent. For both target materials, the peak temperature was about 1.6 times higher for 0.5 mm electron beam compared to the 1 mm beam after reaching their equilibrium. For increasing target thicknesses, the temperature rise caused by the first pulse is similar for all thicknesses, however the temperature difference for subsequent pulses becomes larger until a constant ratio is reached. The target peak temperature after reaching equilibrium can be calculated by adding the steady state temperature and the amplitude of the temperature oscillation. Conclusion: This work indicates the potential to obtain high dose rate irradiation by selecting target material, geometry and electron beam parameters. W25Re may not outperformed tungsten when the target is thick due to its relatively low thermal conductivity. The electron beam size only affects the target temperature but not the PPD. Thin target is preferred to obtain high dose rate and low target temperature, however, the resulting high surface dose is a major concern. NIH funding:R21 EB015957-01; DOD funding:W81XWH-13-1-0165 BL, PM, PB, and RF are founders of TibaRay, Inc. BL is also a borad member. BL and PM have received research grants from Varian Medical System, Inc. and RaySearch Laboratory. RF is an employee of Siemens Healthcare GmbH.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seibert, Tyler M.; Karunamuni, Roshan; Bartsch, Hauke
Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI beforemore » and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maeda, Azusa; Department of Medical Biophysics, University of Toronto, Toronto, Ontario; Chen, Yonghong
Purpose: To investigate the effect of high-dose irradiation on pancreatic tumor vasculature and microenvironment using in vivo imaging techniques. Methods and Materials: A BxPC3 pancreatic tumor xenograft was established in a dorsal skinfold window chamber model and a subcutaneous hind leg model. Tumors were irradiated with a single dose of 4, 12, or 24 Gy. The dorsal skinfold window chamber model was used to assess tumor response, vascular function and permeability, platelet and leukocyte adhesion to the vascular endothelium, and tumor hypoxia for up to 14 days after 24-Gy irradiation. The hind leg model was used to monitor tumor size, hypoxia, and vascularitymore » for up to 65 days after 24-Gy irradiation. Tumors were assessed histologically to validate in vivo observations. Results: In vivo fluorescence imaging revealed temporary vascular dysfunction in tumors irradiated with a single dose of 4 to 24 Gy, but most significantly with a single dose of 24 Gy. Vascular functional recovery was observed by 14 days after irradiation in a dose-dependent manner. Furthermore, irradiation with 24 Gy caused platelet and leukocyte adhesion to the vascular endothelium within hours to days after irradiation. Vascular permeability was significantly higher in irradiated tumors compared with nonirradiated controls 14 days after irradiation. This observation corresponded with increased expression of hypoxia-inducible factor-1α in irradiated tumors. In the hind leg model, irradiation with a single dose of 24 Gy led to tumor growth delay, followed by tumor regrowth. Conclusions: Irradiation of the BxPC3 tumors with a single dose of 24 Gy caused transient vascular dysfunction and increased expression of hypoxia-inducible factor-1α. Such biological changes may impact tumor response to high single-dose and hypofractionated irradiation, and further investigations are needed to better understand the clinical outcomes of stereotactic body radiation therapy.« less
Huang, Yin-Qiu; Ma, Xiao; Wang, Jian; Zhao, Yan-Ling; Wang, Jia-Bo; Chen, Zhe; Zhu, Yun; Shan, Li-Mei; Wei, Shi-Zhang; Wang, Ji; Xiao, Xiao-He
2016-01-01
Objective: Hyperbilirubinemia is one of the most devastating pathologies induced by various liver diseases. Formulae related to Paeoniae Radix Rubra (PRR) at high doses have been applied to treat hyperbilirubinemia in traditional Chinese medicine (TCM). The aim of this systematic review and meta-analysis is to assess the efficacy and safety of formulae relevant to high-dose PRR in patients suffering from hyperbilirubinemia induced by viral hepatitis. Methods: We performed a meta-analysis of randomized-controlled clinical trials to evaluate the efficacy and safety of formulae that apply a high dose of PRR for hyperbilirubinemia. Seven databases were searched until April, 2015. All studies were included according to detailed criteria and assessed for methodological quality. The outcome measurements were recorded for further analysis using the RevMan 5.2.11 software. Results: Fifteen articles involving 1323 patients with hyperbilirubinemia were included. Formulae with high-dose PRR might promote the efficacy of either a combined application ([OR: 3.98, 95% CI (2.91, 5.43)]; P < 0.01) or a single application ([OR: 4.00, 95% CI (1.50, 10.68)]; P < 0.01) for hyperbilirubinemia. The indices of TBIL, ALT, and AST significantly decreased ([MD: –75.57, 95% CI (−94.88, −56.26)], [MD: −26.54, 95% CI (−36.19, −16.88)], and ([MD: −28.94, 95% CI (−46.26, −11.61)]; P < 0.01), respectively. In addition, formulae with high-dose PRR could enhance the treatment efficacy of hyperbilirubinemia triggered by hepatitis B ([OR: 2.98, 95% CI (1.75, 5.05)]; P < 0.01). Furthermore, the efficacy was enhanced with an increasing dosage of PRR. Two articles reported that no side effects occurred in clinical trials, and three studies noted that patients presented light digestive tract symptoms. Conclusion: Formulae relevant to high-dose PRR ameliorate hyperbilirubinemia and might constitute a promising therapeutic approach. For widespread acceptance by practitioners, more rigorously designed multicenter, double-blind, randomized, and large-scale controlled trials are required. PMID:27047379
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iuchi, Toshihiko, E-mail: tiuchi@chiba-c.jp; Hatano, Kazuo; Kodama, Takashi
Purpose/Objectives: To assess the effect and toxicity of hypofractionated high-dose intensity modulated radiation therapy (IMRT) with concurrent and adjuvant temozolomide (TMZ) in 46 patients with newly diagnosed glioblastoma multiforme (GBM). Methods and Materials: All patients underwent postsurgical hypofractionated high-dose IMRT. Three layered planning target volumes (PTVs) were contoured. PTV1 was the surgical cavity and residual tumor on T1-weighted magnetic resonance images with 5-mm margins, PTV2 was the area with 15-mm margins surrounding the PTV1, and PTV3 was the high-intensity area on fluid-attenuated inversion recovery images. Irradiation was performed in 8 fractions at total doses of 68, 40, and 32 Gy formore » PTV1, PTV2, and PTV3, respectively. Concurrent TMZ was given at 75 mg/m{sup 2}/day for 42 consecutive days. Adjuvant TMZ was given at 150 to 200 mg/m{sup 2}/day for 5 days every 28 days. Overall and progression-free survivals were evaluated. Results: No acute IMRT-related toxicity was observed. The dominant posttreatment failure pattern was dissemination. During a median follow-up time of 16.3 months (range, 4.3-80.8 months) for all patients and 23.7 months (range, 12.4-80.8 months) for living patients, the median overall survival was 20.0 months after treatment. Radiation necrosis was diagnosed in 20 patients and was observed not only in the high-dose field but also in the subventricular zone (SVZ). Necrosis in the SVZ was significantly correlated with prolonged survival (hazard ratio, 4.08; P=.007) but caused deterioration in the performance status of long-term survivors. Conclusions: Hypofractionated high-dose IMRT with concurrent and adjuvant TMZ altered the dominant failure pattern from localized to disseminated and prolonged the survival of patients with GBM. Necrosis in the SVZ was associated with better patient survival, but the benefit of radiation to this area remains controversial.« less
NASA Astrophysics Data System (ADS)
Laguda, Edcer Jerecho
Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient's medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method. Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three approaches were applied in this research for dosimetric evaluation on CT images with severe metal artefacts. The first part of the research used a water phantom with four iodine syringes. Two sets of plans, multi-arc plans and single-arc plans, using the Volumetric Modulated Arc therapy (VMAT) technique were designed to avoid or minimize influences from high-density objects. The second part of the research used projection-based MAR Algorithm and the Dual-Energy Method. Calculated Doses (Mean, Minimum, and Maximum Doses) to the planning treatment volume (PTV) were compared and homogeneity index (HI) calculated. Results: (1) Without the GSI-based MAR application, a percent error between mean dose and the absolute dose ranging from 3.4-5.7% per fraction was observed. In contrast, the error was decreased to a range of 0.09-2.3% per fraction with the GSI-based MAR algorithm. There was a percent difference ranging from 1.7-4.2% per fraction between with and without using the GSI-based MAR algorithm. (2) A range of 0.1-3.2% difference was observed for the maximum dose values, 1.5-10.4% for minimum dose difference, and 1.4-1.7% difference on the mean doses. Homogeneity indexes (HI) ranging from 0.068-0.065 for dual-energy method and 0.063-0.141 with projection-based MAR algorithm were also calculated. Conclusion: (1) Percent error without using the GSI-based MAR algorithm may deviate as high as 5.7%. This error invalidates the goal of Radiation Therapy to provide a more precise treatment. Thus, GSI-based MAR algorithm was desirable due to its better dose calculation accuracy. (2) Based on direct numerical observation, there was no apparent deviation between the mean doses of different techniques but deviation was evident on the maximum and minimum doses. The HI for the dual-energy method almost achieved the desirable null values. In conclusion, the Dual-Energy method gave better dose calculation accuracy to the planning treatment volume (PTV) for images with metal artefacts than with or without GE MAR Algorithm.
Watanabe, Toshio; Takeuchi, Toshihisa; Handa, Osamu; Sakata, Yasuhisa; Tanigawa, Tetsuya; Shiba, Masatsugu; Naito, Yuji; Higuchi, Kazuhide; Fujimoto, Kazuma; Yoshikawa, Toshikazu; Arakawa, Tetsuo
2015-01-01
Background Low-dose aspirin (LDA) frequently causes small bowel injury. While some drugs have been reported to be effective in treating LDA-induced small intestinal damage, most studies did not exclude patients with mild damage thought to be clinically insignificant. Aim We conducted a multicenter, randomized, double-blind, placebo-controlled trial to assess the efficacy of a high dose of rebamipide, a gastroprotective drug, for LDA-induced moderate-to-severe enteropathy. Methods We enrolled patients who received 100 mg of enteric-coated aspirin daily for more than 3 months and were found to have more than 3 mucosal breaks (i.e., erosions or ulcers) in the small intestine by capsule endoscopy. Eligible patients were assigned to receive either rebamipide 300 mg (triple dose) 3 times daily or placebo for 8 weeks in a 2:1 ratio. Capsule endoscopy was then repeated. The primary endpoint was the change in the number of mucosal breaks from baseline to 8 weeks. Secondary endpoints included the complete healing of mucosal breaks at 8 weeks and the change in Lewis score (an endoscopic score assessing damage severity) from baseline to 8 weeks. Results The study was completed by 38 patients (rebamipide group: n = 25, placebo group: n = 13). After 8 weeks of treatment, rebamipide, but not placebo, significantly decreased the number of mucosal breaks (p = 0.046). While the difference was not significant (p = 0.13), the rate of complete mucosal break healing in the rebamipide group (32%, 8 of 25) tended to be higher than that in the placebo group (7.7%, 1 of 13). Rebamipide treatment significantly improved intestinal damage severity as assessed by the Lewis score (p = 0.02), whereas placebo did not. The triple dose of rebamipide was well tolerated. Conclusions High-dose rebamipide is effective for the treatment of LDA-induced moderate-to-severe enteropathy. Trial Registration UMIN Clinical Trials Registry UMIN000003463 PMID:25874951
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Y; UT Southwestern Medical Center, Dallas, TX; Tian, Z
2015-06-15
Purpose: Intensity-modulated proton therapy (IMPT) is increasingly used in proton therapy. For IMPT optimization, Monte Carlo (MC) is desired for spots dose calculations because of its high accuracy, especially in cases with a high level of heterogeneity. It is also preferred in biological optimization problems due to the capability of computing quantities related to biological effects. However, MC simulation is typically too slow to be used for this purpose. Although GPU-based MC engines have become available, the achieved efficiency is still not ideal. The purpose of this work is to develop a new optimization scheme to include GPU-based MC intomore » IMPT. Methods: A conventional approach using MC in IMPT simply calls the MC dose engine repeatedly for each spot dose calculations. However, this is not the optimal approach, because of the unnecessary computations on some spots that turned out to have very small weights after solving the optimization problem. GPU-memory writing conflict occurring at a small beam size also reduces computational efficiency. To solve these problems, we developed a new framework that iteratively performs MC dose calculations and plan optimizations. At each dose calculation step, the particles were sampled from different spots altogether with Metropolis algorithm, such that the particle number is proportional to the latest optimized spot intensity. Simultaneously transporting particles from multiple spots also mitigated the memory writing conflict problem. Results: We have validated the proposed MC-based optimization schemes in one prostate case. The total computation time of our method was ∼5–6 min on one NVIDIA GPU card, including both spot dose calculation and plan optimization, whereas a conventional method naively using the same GPU-based MC engine were ∼3 times slower. Conclusion: A fast GPU-based MC dose calculation method along with a novel optimization workflow is developed. The high efficiency makes it attractive for clinical usages.« less
2014-01-01
Background Significant interest has emerged in the therapeutic and interactive effects of different cannabinoids. Cannabidiol (CBD) has been shown to have anxiolytic and antipsychotic effects with high doses administered orally. We report a series of studies conducted to determine the vaporisation efficiency of high doses of CBD, alone and in combination with ∆9-tetrahydrocannabinol (THC), to achieve faster onset effects in experimental and clinical trials and emulate smoked cannabis. Methods Purified THC and CBD (40 mg/ml and 100 mg/ml respectively) were loaded onto a liquid absorbing pad in a Volcano® vaporiser, vaporised and the vapours quantitatively analysed. Preliminary studies determined 200 mg CBD to be the highest dose effectively vaporised at 230°C, yielding an availability of approximately 40% in the vapour phase. Six confirmatory studies examined the quantity of each compound delivered when 200 mg or 4 mg CBD was loaded together with 8 mg of THC. Results THC showed 55% availability when vaporised alone or with low dose CBD, while large variation in the availability of high dose CBD impacted upon the availability of THC when co-administered, with each compound affecting the vaporisation efficiency of the other in a dynamic and dose-dependent manner. We describe optimised protocols that enable delivery of 160 mg CBD through vaporisation. Conclusions While THC administration by vaporisation is increasingly adopted in experimental studies, often with oral predosing with CBD to examine interactive effects, no studies to date have reported the administration of CBD by vaporisation. We report the detailed methodology aimed at optimising the efficiency of delivery of therapeutic doses of CBD, alone and in combination with THC, by vaporisation. These protocols provide a technical advance that may inform methodology for clinical trials in humans, especially for examining interactions between THC and CBD and for therapeutic applications of CBD. Trial registration Current Controlled Trials ISRCTN24109245 PMID:25319497
Zargan, S.; Ghafarian, P.; Shabestani Monfared, A.; Sharafi, A.A.; Bakhshayeshkaram, M.; Ay, M.R.
2017-01-01
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT and cyclotron center. Materials and Methods: 80 patients participated in this study. Thermoluminescence, electronic personal dosimeter and Geiger-Muller dosimeter were also utilized for measurement purpose. Results: The mean annual equivalent organ dose for scanning operator with regard to lens of eyes, thyroid, breast and finger according to mean±SD value, were 0.262±0.044, 0.256±0.046, 0.257±0.040 and 0.316±0.118, respectively. The maximum and minimum estimated annual whole body doses were observed for injector and the chemist group with values of (3.98±0.021) mSv/yr and (1.64±0.014) mSv/yr, respectively. The observed dose rates were 5.67 µSv/h in uptake room at the distance of 0.5 meter from the patient whereas the value 4.94 and 3.08 µSv/h were recorded close to patient’s head in PET/CT room and 3.5 meter from the reception desk. Conclusion: In this study, the injector staff and scanning operator received the first high level and second high level of radiation. This study confirmed that low levels of radiation dose were received by all radiation staff during PET/CT procedure using 18F-FDG due to efficient shielding and using trained radiation staff in PET/CT and cyclotron center of Masih Daneshvari hospital. PMID:28451574
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viani, Gustavo Arruda; Stefano, Eduardo Jose; Afonso, Sergio Luis
2009-08-01
Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results:more » Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p < 0.0001). However, there was no difference in the mortality rate (p = 0.38) and specific prostate cancer mortality rates (p = 0.45) between the groups receiving HDRT and CDRT. However, there were more cases of late Grade >2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.« less
Folic acid supplementation before and during pregnancy in the Newborn Epigenetics STudy (NEST)
2011-01-01
Background Folic acid (FA) added to foods during fortification is 70-85% bioavailable compared to 50% of folate occurring naturally in foods. Thus, if FA supplements also are taken during pregnancy, both mother and fetus can be exposed to FA exceeding the Institute of Medicine's recommended tolerable upper limit (TUL) of 1,000 micrograms per day (μg/d) for adult pregnant women. The primary objective is to estimate the proportion of women taking folic acid (FA) doses exceeding the TUL before and during pregnancy, and to identify correlates of high FA use. Methods During 2005-2008, pre-pregnancy and pregnancy-related data on dietary supplementation were obtained by interviewing 539 pregnant women enrolled at two obstetrics-care facilities in Durham County, North Carolina. Results Before pregnancy, 51% of women reported FA supplementation and 66% reported this supplementation during pregnancy. Before pregnancy, 11.9% (95% CI = 9.2%-14.6%) of women reported supplementation with FA doses above the TUL of 1,000 μg/day, and a similar proportion reported this intake prenatally. Before pregnancy, Caucasian women were more likely to take FA doses above the TUL (OR = 2.99; 95% = 1.28-7.00), compared to African American women, while women with chronic conditions were less likely to take FA doses above the TUL (OR = 0.48; 95%CI = 0.21-0.97). Compared to African American women, Caucasian women were also more likely to report FA intake in doses exceeding the TUL during pregnancy (OR = 5.09; 95%CI = 2.07-12.49). Conclusions Fifty-one percent of women reported some FA intake before and 66% during pregnancy, respectively, and more than one in ten women took FA supplements in doses that exceeded the TUL. Caucasian women were more likely to report high FA intake. A study is ongoing to identify possible genetic and non-genotoxic effects of these high doses. PMID:21255390
SU-F-T-18: The Importance of Immobilization Devices in Brachytherapy Treatments of Vaginal Cuff
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shojaei, M; Dumitru, N; Pella, S
2016-06-15
Purpose: High dose rate brachytherapy is a highly localized radiation therapy that has a very high dose gradient. Thus one of the most important parts of the treatment is the immobilization. The smallest movement of the patient or applicator can result in dose variation to the surrounding tissues as well as to the tumor to be treated. We will revise the ML Cylinder treatments and their localization challenges. Methods: A retrospective study of 25 patients with 5 treatments each looking into the applicator’s placement in regard to the organs at risk. Motion possibilities for each applicator intra and inter fractionationmore » with their dosimetric implications were covered and measured in regard with their dose variance. The localization immobilization devices used were assessed for the capability to prevent motion before and during the treatment delivery. Results: We focused on the 100% isodose on central axis and a 15 degree displacement due to possible rotation analyzing the dose variations to the bladder and rectum walls. The average dose variation for bladder was 15% of the accepted tolerance, with a minimum variance of 11.1% and a maximum one of 23.14% on the central axis. For the off axis measurements we found an average variation of 16.84% of the accepted tolerance, with a minimum variance of 11.47% and a maximum one of 27.69%. For the rectum we focused on the rectum wall closest to the 120% isodose line. The average dose variation was 19.4%, minimum 11.3% and a maximum of 34.02% from the accepted tolerance values Conclusion: Improved immobilization devices are recommended. For inter-fractionation, localization devices are recommended in place with consistent planning in regards with the initial fraction. Many of the present immobilization devices produced for external radiotherapy can be used to improve the localization of HDR applicators during transportation of the patient and during treatment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun
Purpose: There are uncertainties associated with the prediction of colorectal cancer (CRC) risk from highly energetic heavy ion (HZE) radiation. We undertook a comprehensive assessment of intestinal and colonic tumorigenesis induced after exposure to high linear energy transfer (high-LET) HZE radiation spanning a range of doses and LET in a CRC mouse model and compared the results with the effects of low-LET γ radiation. Methods and Materials: Male and female APC{sup 1638N/+} mice (n=20 mice per group) were whole-body exposed to sham-radiation, γ rays, {sup 12}C, {sup 28}Si, or {sup 56}Fe radiation. For the >1 Gy HZE dose, we used γ-ray equitoxicmore » doses calculated using relative biological effectiveness (RBE) determined previously. The mice were euthanized 150 days after irradiation, and intestinal and colon tumor frequency was scored. Results: The highest number of tumors was observed after {sup 28}Si, followed by {sup 56}Fe and {sup 12}C radiation, and tumorigenesis showed a male preponderance, especially after {sup 28}Si. Analysis showed greater tumorigenesis per unit of radiation (per cGy) at lower doses, suggesting either radiation-induced elimination of target cells or tumorigenesis reaching a saturation point at higher doses. Calculation of RBE for intestinal and colon tumorigenesis showed the highest value with {sup 28}Si, and lower doses showed greater RBE relative to higher doses. Conclusions: We have demonstrated that the RBE of heavy ion radiation-induced intestinal and colon tumorigenesis is related to ion energy, LET, gender, and peak RBE is observed at an LET of 69 keV/μm. Our study has implications for understanding risk to astronauts undertaking long duration space missions.« less
SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souri, S; Ahmed, Y; Cao, Y
2014-06-15
Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, amore » pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.« less
Shinkai, Shoji; Toba, Masamichi; Saito, Takao; Sato, Ikutaro; Tsubouchi, Mina; Taira, Kiyoto; Kakumoto, Keiji; Inamatsu, Takashi; Yoshida, Hiroto; Fujiwara, Yoshinori; Fukaya, Taro; Matsumoto, Tetsuya; Tateda, Kazuhiro; Yamaguchi, Keizo; Kohda, Noriyuki; Kohno, Shigeru
2013-05-28
Oral intake of Lactobacillus pentosus strain b240 (b240) has been shown to enhance the secretion of salivary secretory IgA in elderly adults. However, its clinical benefits remain to be determined. We tested the hypothesis that b240 exerts a protective effect against the common cold in elderly adults. The design of the present study was a randomised, double-blind, placebo-controlled trial (RCT) with parallel three-group comparison. For this purpose, 300 eligible elderly adults were randomly allocated to one of three groups, namely a placebo, low-dose or high-dose b240 group. Participants in the low-dose and high-dose b240 groups were given tablets containing 2 × 10(9) or 2 × 10(10) cells, respectively, of heat-killed b240, while those in the placebo group were given tablets without b240. Each group consumed their respective tablets once daily for 20 weeks. The common cold was assessed on the basis of a diary. Change in quality of life was evaluated using the SF-36. Of the total participants, 280 completed the 20-week RCT. The accumulated incidence rate of the common cold was 47·3, 34·8 and 29·0 % for the placebo, low-dose b240 and high-dose b240 groups, respectively (P for trend = 0·012). Lower incidence rates were consistently observed throughout the experimental period in the b240 groups (log-rank test, P= 0·034). General health perception, as determined by the SF-36®, dose-dependently increased in the b240 groups ( P <0·025). In conclusion, oral intake of b240 significantly reduced the incidence rate of the common cold in elderly adults, indicating that b240 might be useful in improving resistance against infection through mucosal immunity.
Hypoxia-preconditioned mesenchymal stem cells ameliorate ischemia/reperfusion-induced lung injury
Chiang, Chi-Huei; Hung, Shih-Chieh; Chian, Chih-Feng; Tsai, Chen-Liang; Chen, Wei-Chih; Zhang, Haibo
2017-01-01
Background Hypoxia preconditioning has been proven to be an effective method to enhance the therapeutic action of mesenchymal stem cells (MSCs). However, the beneficial effects of hypoxic MSCs in ischemia/reperfusion (I/R) lung injury have yet to be investigated. In this study, we hypothesized that the administration of hypoxic MSCs would have a positive therapeutic impact on I/R lung injury at molecular, cellular, and functional levels. Methods I/R lung injury was induced in isolated and perfused rat lungs. Hypoxic MSCs were administered in perfusate at a low (2.5×105 cells) and high (1×106 cells) dose. Rats ventilated with a low tidal volume of 6 ml/kg served as controls. Hemodynamics, lung injury indices, inflammatory responses and activation of apoptotic pathways were determined. Results I/R induced permeability pulmonary edema with capillary leakage and increased levels of reactive oxygen species (ROS), pro-inflammatory cytokines, adhesion molecules, cytosolic cytochrome C, and activated MAPK, NF-κB, and apoptotic pathways. The administration of a low dose of hypoxic MSCs effectively attenuated I/R pathologic lung injury score by inhibiting inflammatory responses associated with the generation of ROS and anti-apoptosis effect, however this effect was not observed with a high dose of hypoxic MSCs. Mechanistically, a low dose of hypoxic MSCs down-regulated P38 MAPK and NF-κB signaling but upregulated glutathione, prostaglandin E2, IL-10, mitochondrial cytochrome C and Bcl-2. MSCs infused at a low dose migrated into interstitial and alveolar spaces and bronchial trees, while MSCs infused at a high dose aggregated in the microcirculation and induced pulmonary embolism. Conclusions Hypoxic MSCs can quickly migrate into extravascular lung tissue and adhere to other inflammatory or structure cells and attenuate I/R lung injury through anti-oxidant, anti-inflammatory and anti-apoptotic mechanisms. However, the dose of MSCs needs to be optimized to prevent pulmonary embolism and thrombosis. PMID:29117205
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorbe, Bengt; Straumits, Andris; Karlsson, Leif
2005-08-01
Purpose To compare two different fractionation schedules for postoperative vaginal high-dose-rate (HDR) irradiation in endometrial carcinomas. Methods and Materials In a complete geographic series of 290 low-risk endometrial carcinomas, the efficacy and side effects of two different fractionation schedules for postoperative vaginal irradiation were evaluated. The patients were treated during the years 1989-2003. The tumors were in International Federation of Gynecology and Obstetrics Stages IA-IB and Grades 1-2. The HDR MicroSelectron afterloading equipment (iridium-192) was used. Perspex vaginal applicators with diameters of 20-30 mm were used, and the dose was specified at 5 mm from the surface of the applicator.more » Six fractions were given, and the overall treatment time was 8 days. The size of the dose per fraction was randomly set to 2.5 Gy (total dose of 15.0 Gy) or 5.0 Gy (total dose of 30.0 Gy). One hundred forty-four patients were treated with the 2.5-Gy fraction and 146 patients with the 5.0-Gy fraction. Results The overall locoregional recurrence rate of the complete series was 1.4% and the rate of vaginal recurrences 0.7%. There was no difference between the two randomized groups. The vaginal shortening measured by colpometry was not significant (p = 0.159) in the 2.5-Gy group (mean, 0.3 cm) but was highly significant (p < 0.000001) in the 5.0-Gy group (mean 2.1 cm) after 5 years. Mucosal atrophy and bleedings were significantly more frequent in the 5.0-Gy group. Symptoms noted in the 2.5-Gy group were not different from what could be expected in a normal group of postmenopausal women. Conclusion The fractionation schedule recommended for postoperative vaginal irradiation in low-risk endometrial carcinoma is six fractions of 2.5 Gy when the HDR technique is used.« less
Phase II Study of High-Dose Photon/Proton Radiotherapy in the Management of Spine Sarcomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeLaney, Thomas F.; Liebsch, Norbert J.; Pedlow, Francis X.
Purpose: Radiotherapy (XRT) for spine sarcomas is constrained by spinal cord, nerve, and viscera tolerance. Negative surgical margins are uncommon; hence, doses of {>=}66 Gy are recommended. A Phase II clinical trial evaluated high-dose photon/proton XRT for spine sarcomas. Methods and Materials: Eligible patients had nonmetastatic, thoracic, lumbar, and/or sacral spine/paraspinal sarcomas. Treatment included pre- and/or postoperative photon/proton XRT with or without radical resection; patients with osteosarcoma and Ewing's sarcoma received chemotherapy. Shrinking fields delivered 50.4 cobalt Gray equivalent (Gy RBE) to subclinical disease, 70.2 Gy RBE to microscopic disease in the tumor bed, and 77.4 Gy RBE to grossmore » disease at 1.8 Gy RBE qd. Doses were reduced for radiosensitive histologies, concurrent chemoradiation, or when diabetes or autoimmune disease present. Spinal cord dose was limited to 63/54 Gy RBE to surface/center. Intraoperative boost doses of 7.5 to 10 Gy could be given by dural plaque. Results: A total of 50 patients (29 chordoma, 14 chondrosarcoma, 7 other) underwent gross total (n = 25) or subtotal (n = 12) resection or biopsy (n = 13). With 48 month median follow-up, 5-year actuarial local control, recurrence-free survival, and overall survival are: 78%, 63%, and 87% respectively. Two of 36 (5.6%) patients treated for primary versus 7/14 (50%) for recurrent tumor developed local recurrence (p < 0.001). Five patients developed late radiation-associated complications; no myelopathy developed but three sacral neuropathies appeared after 77.12 to 77.4 Gy RBE. Conclusions: Local control with this treatment is high in patients radiated at the time of primary presentation. Spinal cord dose constraints appear to be safe. Sacral nerves receiving 77.12-77.4 Gy RBE are at risk for late toxicity.« less
Santoleri, Fiorenzo; Lasala, Ruggero; Logreco, Andrea; Ranucci, Elena; Costantini, Alberto
2018-01-01
Purpose The aim of this study was to verify whether the distribution of a treatment diary by a pharmacist could influence the adherence to oral treatment with imatinib, nilotinib, and dasatinib in patients with chronic myeloid leukaemia. Methods The level of adherence was calculated using the received daily dose/prescribed daily dose ratio and compared between patients who used a diary and those who did not. Results Forty-four (35.8%) of 123 patients with chronic myeloid leukaemia completed the diary: 20 (45.4%) receiving imatinib, 17 (38.6%) receiving nilotinib, and seven (15.9%) receiving dasatinib. Treatment adherence with the diary calculated using received daily dose/prescribed daily dose method was 93.6% (imatinib 94.9%, nilotinib 91.1%, and dasatinib 95.8%). Adherence during the period without a diary was 86.5% (84.9, 87.4, and 90%). Adherence was significantly greater with than without a diary (p < 0.0001). Conclusions The findings of this study that, in the case of chronic diseases, direct pharmacist-patient contact is important in order to maintain high levels of adherence, and a treatment diary is a valid means of doing this. According to these data, it is necessary to support similar patient-oriented programmes in order to ensure high levels of adherence and optimize drug management.
Survival of tumor cells after proton irradiation with ultra-high dose rates
2011-01-01
Background Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >109 Gy s-1may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. Methods The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within < 1 ns or 100 ms, respectively. Investigated endpoints were G2 phase cell cycle arrest, apoptosis, and colony formation. Results At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE) for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD), respectively. Conclusions At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional) continuous irradiation mode do not differ significantly. PMID:22008289
Livingstone, J; Horowitz, Y S; Oster, L; Datz, H; Lerch, M; Rosenfeld, A; Horowitz, A
2010-03-01
The dose response of LiF:Mg,Ti (TLD-100) chips was measured from 1 to 50,000 Gy using 100 keV X rays at the European Synchroton Radiation Facility. Glow curves were deconvoluted into component glow peaks using a computerised glow curve deconvolution (CGCD) code based on first-order kinetics. The normalised dose response, f(D), of glow peaks 4 and 5 and 5b (the major components of composite peak 5), as well as peaks 7 and 8 (two of the major components of the high-temperature thermoluminescence (HTTL) at high levels of dose) was separately determined and theoretically interpreted using the unified interaction model (UNIM). The UNIM is a nine-parameter model encompassing both the irradiation/absorption stage and the thermally induced relaxation/recombination stage with an admixture of both localised and delocalised recombination mechanisms. The effects of radiation damage are included in the present modelling via the exponential removal of luminescent centres (LCs) at high dose levels. The main features of the experimentally measured dose response are: (i) increase in f(D)(max) with glow peak temperature, (ii) increase in D(max) (the dose level at which f(D)(max) occurs) with increasing glow peak temperature, and (iii) decreased effects of radiation damage with increasing glow peak temperature. The UNIM interpretation of this behaviour requires both strongly decreasing values of ks (the relative contribution of localised recombination) as a function of glow peak temperature and, as well, significantly different values of the dose-filling constants of the trapping centre (TC) and LC for peaks 7 and 8 than those used for peaks 4 and 5. This suggests that different TC/LC configurations are responsible for HTTL. The relative intensity of peak 5a (a low-temperature satellite of peak 5 arising from localised recombination) was found to significantly increase at higher dose levels due to preferential electron and hole population of the trapping/recombination complex giving rise to composite glow peak 5. It is also demonstrated that possible changes in the trapping cross section of the LC and the competitive centres due to increasing sample/glow peak temperature do not significantly influence these observations/conclusions.
Guarnotta, Valentina; Riela, Serena; Massaro, Marina; Bonventre, Sebastiano; Inviati, Angela; Ciresi, Alessandro; Pizzolanti, Giuseppe; Benvenga, Salvatore; Giordano, Carla
2017-01-01
The consumption of soft drinks is a crucial factor in determining persistent hypocalcemia. The aim of the study is to evaluate the biochemical mechanisms inducing hypocalcemia in a female patient with usual high consumption of cola drink and persistent hypocalcemia, who failed to respond to high doses of calcium and calcitriol supplementation. At baseline and after pentagastrin injection, gastric secretion (Gs) and duodenal secretion (Ds) samples were collected and calcium and total phosphorus (P tot ) concentrations were evaluated. At the same time, blood calcium, P tot , sodium, potassium, chloride, magnesium concentrations, and vitamin D were sampled. After intake of cola (1 L) over 180 min, Gs and Ds and blood were collected and characterized in order to analyze the amount of calcium and P tot or sodium, potassium, magnesium, and chloride ions, respectively. A strong pH decrease was observed after cola intake with an increase in phosphorus concentration. Consequently, a decrease in calcium concentration in Gs and Ds was observed. A decrease in calcium concentration was also observed in blood. In conclusion, we confirm that in patients with postsurgical hypoparathyroidism, the intake of large amounts of cola containing high amounts of phosphoric acid reduces calcium absorption efficiency despite the high doses of calcium therapy.
SU-G-206-15: Effects of Dose Reduction On Emphysema Score
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lo, P; Wahi-Anwar, M; Kim, H
Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noisemore » to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Renu; Jursinic, Paul A.
2013-07-15
Purpose: To show the feasibility of clinical implementation of OSLDs for high dose-rate (HDR) in vivo dosimetry for gynecological and breast patients. To discuss how the OSLDs were characterized for an Ir-192 source, taking into account low gamma energy and high dose gradients. To describe differences caused by the dose calculation formalism of treatment planning systems.Methods: OSLD irradiations were made using the GammaMedplus iX Ir-192 HDR, Varian Medical Systems, Milpitas, CA. BrachyVision versions 8.9 and 10.0, Varian Medical Systems, Milpitas, CA, were used for calculations. Version 8.9 used the TG-43 algorithm and version 10.0 used the Acuros algorithm. The OSLDsmore » (InLight Nanodots) were characterized for Ir-192. Various phantoms were created to assess calculated and measured doses and the angular dependence and self-absorption of the Nanodots. Following successful phantom measurements, patient measurements for gynecological patients and breast cancer patients were made and compared to calculated doses.Results: The OSLD sensitivity to Ir-192 compared to 6 MV is between 1.10 and 1.25, is unique to each detector, and changes with accumulated dose. The measured doses were compared to those predicted by the treatment planning system and found to be in agreement for the gynecological patients to within measurement uncertainty. The range of differences between the measured and Acuros calculated doses was -10%-14%. For the breast patients, there was a discrepancy of -4.4% to +6.5% between the measured and calculated doses at the skin surface when the Acuros algorithm was used. These differences were within experimental uncertainty due to (random) error in the location of the detector with respect to the treatment catheter.Conclusions: OSLDs can be successfully used for HDR in vivo dosimetry. However, for the measurements to be meaningful one must account for the angular dependence, volume-averaging, and the greater sensitivity to Ir-192 gamma rays than to 6 MV x-rays if 6 MV x-rays were used for OSLD calibration. The limitations of the treatment planning algorithm must be understood, especially for surface dose measurements. Use of in vivo dosimetry for HDR brachytherapy treatments is feasible and has the potential to detect and prevent gross errors. In vivo HDR brachytherapy should be included as part of the QA for a HDR brachytherapy program.« less
Demoury, Claire; Marquant, Fabienne; Ielsch, Géraldine; Goujon, Stéphanie; Debayle, Christophe; Faure, Laure; Coste, Astrid; Laurent, Olivier; Guillevic, Jérôme; Laurier, Dominique; Hémon, Denis; Clavel, Jacqueline
2016-01-01
Background: Exposures to high-dose ionizing radiation and high-dose rate ionizing radiation are established risk factors for childhood acute leukemia (AL). The risk of AL following exposure to lower doses due to natural background radiation (NBR) has yet to be conclusively determined. Methods: AL cases diagnosed over 1990–2009 (9,056 cases) were identified and their municipality of residence at diagnosis collected by the National Registry of Childhood Cancers. The Geocap study, which included the 2,763 cases in 2002–2007 and 30,000 population controls, was used for complementary analyses. NBR exposures were modeled on a fine scale (36,326 municipalities) based on measurement campaigns and geological data. The power to detect an association between AL and dose to the red bone marrow (RBM) fitting UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) predictions was 92%, 45% and 99% for exposure to natural gamma radiation, radon and total radiation, respectively. Results: AL risk, irrespective of subtype and age group, was not associated with the exposure of municipalities to radon or gamma radiation in terms of yearly exposure at age reached, cumulative exposure or RBM dose. There was no confounding effect of census-based socio-demographic indicators, or environmental factors (road traffic, high voltage power lines, vicinity of nuclear plants) related to AL in the Geocap study. Conclusions: Our findings do not support the hypothesis that residential exposure to NBR increases the risk of AL, despite the large size of the study, fine scale exposure estimates and wide range of exposures over France. However, our results at the time of diagnosis do not rule out a slight association with gamma radiation at the time of birth, which would be more in line with the recent findings in the UK and Switzerland. Citation: Demoury C, Marquant F, Ielsch G, Goujon S, Debayle C, Faure L, Coste A, Laurent O, Guillevic J, Laurier D, Hémon D, Clavel J. 2017. Residential exposure to natural background radiation and risk of childhood acute leukemia in France, 1990–2009. Environ Health Perspect 125:714–720; http://dx.doi.org/10.1289/EHP296 PMID:27483500
Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Zhang, Jun; Dutta, Sandeep
2013-01-01
Aim The objective of this work was to characterize the safety, tolerability and pharmacokinetics of ABT-288, a highly selective histamine H3 receptor antagonist, in healthy young adults and elderly subjects following single and multiple dosing in a phase 1 setting. Methods Single doses (0.1, 0.3, 1, 3, 10, 20 and 40 mg ABT-288) and multiple doses (0.5, 1.5, 3 and 6 mg ABT-288 once-daily for 14 days) were evaluated in young adults and multiple doses (0.5, 1.5, 3 and 5 mg ABT-288 once-daily for 12 days) were evaluated in elderly subjects using randomized, double-blind, placebo-controlled, dose-escalating study designs. The effect of food on ABT-288 pharmacokinetics (5 mg single dose) was evaluated using an open label, randomized, crossover design. Results ABT-288 safety, tolerability and pharmacokinetics were comparable in young and elderly subjects. Single doses up to 40 mg and multiple doses up to 3 mg once-daily were generally safe and well tolerated. The most frequently reported adverse events were hot flush, headache, abnormal dreams, insomnia, nausea and dizziness. ABT-288 exposure (AUC) was dose-proportional over the evaluated dose ranges. The mean elimination half-life ranged from 40 to 61 h across dose groups. Steady state was achieved by day 10 of once-daily dosing with 3.4- to 4.2-fold accumulation. Food did not have a clinically meaningful effect on ABT-288 exposure. Conclusions Based on the above results, 1 and 3 mg once-daily doses of ABT-288 were advanced to phase 2 evaluation in Alzheimer's patients. PMID:23016924
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swisher-McClure, Samuel, E-mail: Swisher-Mcclure@uphs.upenn.edu; Leonard Davis Institute of Health Economics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA; Mitra, Nandita
Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Usingmore » multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment.« less
A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giantsoudi, D.; Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Boston, Massachusetts 02114; Baltas, D.
2013-04-15
Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the differentmore » dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D{sub 10} or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.« less
Dose Equivalents for Second-Generation Antipsychotic Drugs: The Classical Mean Dose Method
Leucht, Stefan; Samara, Myrto; Heres, Stephan; Patel, Maxine X.; Furukawa, Toshi; Cipriani, Andrea; Geddes, John; Davis, John M.
2015-01-01
Background: The concept of dose equivalence is important for many purposes. The classical approach published by Davis in 1974 subsequently dominated textbooks for several decades. It was based on the assumption that the mean doses found in flexible-dose trials reflect the average optimum dose which can be used for the calculation of dose equivalence. We are the first to apply the method to second-generation antipsychotics. Methods: We searched for randomized, double-blind, flexible-dose trials in acutely ill patients with schizophrenia that examined 13 oral second-generation antipsychotics, haloperidol, and chlorpromazine (last search June 2014). We calculated the mean doses of each drug weighted by sample size and divided them by the weighted mean olanzapine dose to obtain olanzapine equivalents. Results: We included 75 studies with 16 555 participants. The doses equivalent to 1 mg/d olanzapine were: amisulpride 38.3 mg/d, aripiprazole 1.4 mg/d, asenapine 0.9 mg/d, chlorpromazine 38.9 mg/d, clozapine 30.6 mg/d, haloperidol 0.7 mg/d, quetiapine 32.3mg/d, risperidone 0.4mg/d, sertindole 1.1 mg/d, ziprasidone 7.9 mg/d, zotepine 13.2 mg/d. For iloperidone, lurasidone, and paliperidone no data were available. Conclusions: The classical mean dose method is not reliant on the limited availability of fixed-dose data at the lower end of the effective dose range, which is the major limitation of “minimum effective dose methods” and “dose-response curve methods.” In contrast, the mean doses found by the current approach may have in part depended on the dose ranges chosen for the original trials. Ultimate conclusions on dose equivalence of antipsychotics will need to be based on a review of various methods. PMID:25841041
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juang, T; Adamovics, J; Oldham, M
Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, highmore » resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately measuring dose in a deforming structure, and warrants further study to quantify comprehensive accuracy at different levels of deformation. This work was supported by NIH R01CA100835. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.« less
Prideaux, Andrew R.; Song, Hong; Hobbs, Robert F.; He, Bin; Frey, Eric C.; Ladenson, Paul W.; Wahl, Richard L.; Sgouros, George
2010-01-01
Phantom-based and patient-specific imaging-based dosimetry methodologies have traditionally yielded mean organ-absorbed doses or spatial dose distributions over tumors and normal organs. In this work, radiobiologic modeling is introduced to convert the spatial distribution of absorbed dose into biologically effective dose and equivalent uniform dose parameters. The methodology is illustrated using data from a thyroid cancer patient treated with radioiodine. Methods Three registered SPECT/CT scans were used to generate 3-dimensional images of radionuclide kinetics (clearance rate) and cumulated activity. The cumulated activity image and corresponding CT scan were provided as input into an EGSnrc-based Monte Carlo calculation: The cumulated activity image was used to define the distribution of decays, and an attenuation image derived from CT was used to define the corresponding spatial tissue density and composition distribution. The rate images were used to convert the spatial absorbed dose distribution to a biologically effective dose distribution, which was then used to estimate a single equivalent uniform dose for segmented volumes of interest. Equivalent uniform dose was also calculated from the absorbed dose distribution directly. Results We validate the method using simple models; compare the dose-volume histogram with a previously analyzed clinical case; and give the mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for an illustrative case of a pediatric thyroid cancer patient with diffuse lung metastases. The mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for the tumor were 57.7, 58.5, and 25.0 Gy, respectively. Corresponding values for normal lung tissue were 9.5, 9.8, and 8.3 Gy, respectively. Conclusion The analysis demonstrates the impact of radiobiologic modeling on response prediction. The 57% reduction in the equivalent dose value for the tumor reflects a high level of dose nonuniformity in the tumor and a corresponding reduced likelihood of achieving a tumor response. Such analyses are expected to be useful in treatment planning for radionuclide therapy. PMID:17504874
Basu-Roy, Somapriya; Kar, Sanjay Kumar; Das, Sounik; Lahiri, Annesha
2017-01-01
Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and methods We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times (‘no optimization’), ‘manual dwell weight/times’, and ‘graphical’. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D2cc) rectum and rectal point etc.; D2cc, minimum, maximum, median, and average dose to sigmoid colon; D2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced. PMID:29204164
Comparative Study of Different {beta}-Radiation Doses for Preventing Pterygium Recurrence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamada, Takayuki, E-mail: tyamada-oph@umin.ac.jp; Mochizuki, Hideki; Ue, Takahiro
Purpose: To compare the pterygium recurrence rates after treatment with two different {beta}-radiation doses. Methods and Materials: A total of 84 patients with a mean age of 63.0 {+-} 10.3 years (men, 48 eyes, and women, 47 eyes) and initially treated with {beta}-radiation after pterygium excision were recruited. The mean follow-up period was 49.9 {+-} 51.3 months. The patients were assigned to two dose groups: a high-dose (40 Gy) or a low-dose (20 Gy) group. The statistical significance of differences in patient age, pterygium size, and interval between surgery and radiotherapy were analyzed in the 20-Gy group using the Coxmore » proportional hazard model at p < .05. Results: The high- and low-dose groups included 28 and 67 eyes, respectively. Pterygia recurred in 11 eyes, all in the low-dose group. The interval between surgery and radiotherapy was not a significant predictor of recurrence. Smaller pterygia had a lower risk of recurrence than pterygia that had encroached the pupillary area (pterygium located within one-third of the corneal radius from the limbus, corrected hazard ratio [HR], 0.069; 95% confidence interval [CI], 0.006-0.766; p = .030; pterygium extending beyond one-third of the corneal radius, corrected HR, 0.188; 95% CI, 0.018-0.696; p = 0.019; and pterygium reaching the pupillary area, corrected HR, 0.184; 95% CI, 0.036-0.929; p = .040). Older age was marginally significant as a negative predictor of recurrence (HR, 0.943; 95% CI, 0.887-1.003; p = .061). No scleromalacia developed during the follow-up period. Conclusions: {beta}-Radiation at 40 Gy was more efficacious than at 20 Gy in preventing pterygium recurrence without scleromalacia development, particularly for large-size pterygia and those in young patients.« less
Fu, Xiao-Long; Chen, Jun-Chao; Xiang, Jia-Qing
2015-01-01
Purpose To identify the tolerance of radiation with a high prescribed dose and predictors for the development of intrathoracic stomach toxicity in patients with thoracic esophageal squamous cell carcinoma (SCC) after esophagectomy followed by gastric conduit reconstruction. Methods and Materials From 2011 to 2013, 105 patients after esophagectomy were treated with postoperative radiotherapy. The intrathoracic stomach was outlined with the calculation of a dose-volume histogram (DVH) for the initial intended treatment of 6020 cGy or 6300 cGy. The volume of the intrathoracic stomach receiving each dose was recorded at 10-Gy intervals between 10 and 40 Gy and at 5-Gy intervals between 40 and 60 Gy. The grade of toxicities was defined by the National Cancer Institute Common Toxicity Criteria version 4.0. Results The mean and maximum doses of the intrathoracic stomach were 2449 ± 986 cGy and 6519 ± 406 cGy, respectively. Sixteen (15.2%) and three (2.9%) experienced Common Toxicity Criteria Grade 2 and Grade 3 acute gastric toxicity. There were no Grade 4 toxicities. Fourteen patients (13.3%) exhibited late gastric complications possibly related to radiation. The volume percent of the intrathoracic stomach receiving at least 50 Gy (V50) was strongly associated with the degree of toxicity (p = 0.024, respectively). Multivariate analysis of patient and treatment-related factors revealed no other significant predictors of severe toxicities. Conclusions The intrathoracic stomach is well tolerated with a high-dose irradiation for patients with esophageal SCC receiving radiotherapy after esophagectomy. A strong dose-volume relationship exists for the development of Grade 2 acute intrathoracic stomach toxicity in our study. PMID:26314958
Fang, Jing; George, Mary G.; Gindi, Renee M.; Hong, Yuling; Yang, Quanhe; Ayala, Carma; Ward, Brian W.; Loustalot, Fleetwood
2015-01-01
Current guidelines recommend that adults with atherosclerotic cardiovascular disease take low-dose aspirin or other antiplatelet medications as secondary prevention of recurrent cardiovascular events. Yet, no national level assessment of low-dose aspirin use for secondary prevention of cardiovascular disease has been reported among a community-based population. Using data from the 2012 National Health Interview Survey, we assessed low-dose aspirin use among those with atherosclerotic cardiovascular disease. We estimated the prevalence ratios of low-dose aspirin use, adjusting for sociodemographic status, health insurance, and cardiovascular risk factors. Among those with atherosclerotic cardiovascular disease (n=3,068), 76% had been instructed to take aspirin, and 88% of those were following this advice. Of those not advised, 11% took aspirin on this own. Overall, 70% were taking aspirin (including those who followed their health care provider's advice and those who were not advised but took aspirin on their own). Logistic regression models showed that women, non-Hispanic blacks and Hispanics, those aged 40–64 years, with a high school education or with some college, or with fewer cardiovascular disease risk factors were less likely to take aspirin than men, non-Hispanic whites, those aged ≥65 years, with a college education or higher, or with all four selected cardiovascular disease risk factors, respectively. Additional analyses conducted among those with coronary heart disease only (n=2,007) showed similar patterns. In conclusion, use of low-dose aspirin for secondary prevention was 70%, with high reported adherence to health care providers' advice to take low-dose aspirin (88%), and significant variability within subgroups. PMID:25670639
Fabian, Dusan; Dusan, Fabian; Sabol, Marián; Marián, Sabol; Domaracká, Katarína; Katarína, Domaracká; Bujnáková, Dobroslava; Dobroslava, Bujnáková
2006-12-01
Essential oils are known to possess antimicrobial activity against a wide spectrum of bacteria. The main objective of this study was to evaluate possible harmful effects of four commonly used essential oils and their major components on intestinal cells. Antimicrobial activity of selected plant extracts against enteroinvasive Escherichia coli was dose dependent. However, doses of essential oils with the ability to completely inhibit bacterial growth (0.05%) showed also relatively high cytotoxicity to intestinal-like cells cultured in vitro. Lower doses of essential oils (0.01%) had only partial antimicrobial activity and their damaging effect on Caco-2 cells was only modest. Cell death assessment based on morphological and viability staining followed by fluorescence microscopy showed that essential oils of cinnamon and clove and their major component eugenol had almost no cytotoxic effect at lower doses. Although essential oil of oregano and its component carvacrol slightly increased the incidence of apoptotic cell death, they showed extensive antimicrobial activity even at lower concentrations. Relatively high cytotoxicity was demonstrated by thyme oil, which increased both apoptotic and necrotic cell death incidence. In contrast, its component thymol showed no cytotoxic effect as well as greatly-reduced ability to inhibit visible growth of the chosen pathogen in the doses used. On the other hand, the addition of all essential oils and their components at lower doses, with the exception of thyme oil, to bacterial suspension significantly reduced the cytotoxic effect of E. coli on Caco-2 cells after 1h culture. In conclusion, it is possible to find appropriate doses of essential oils showing both antimicrobial activity and very low detrimental effect on intestinal cells.
Pan, S Y; Han, Y F; Yu, Z L; Yang, R; Dong, H; Ko, K M
2006-09-01
The potential of tacrine in altering cognitive/behavioral function as well as in causing toxicity was evaluated in mice of 17 and 30 days of age. Cognitive and behavioral studies were performed using a step-through passive avoidance task and a habituation open-field test with a 24-h retention interval. Tacrine was subcutaneously injected (1.25-80 micro mol/kg) 30 min prior to the first session of both tests. During the training session in step-through task, tacrine treatment dose-dependently decreased the number of footshocks, with IC(50) values being 7.8 and 23.3 micro mol/kg in 17- and 30-day-old mice, respectively. Treatment with tacrine at a low dose (5 micro mol/kg) significantly prolonged the retention latency in 17-day-old mice only, but it shortened the retention latency at high doses of 20 and 40 micro mol/kg in 17- and 30-day-old, respectively. During the acquisition session in the open-field test, tacrine treatment dose-dependently decreased the locomotor activity in 17- and 30-day-old mice, with IC(50) values being 15.1 and 24.7 micro mol/kg, respectively. High doses of tacrine invariably increased the locomotor activity during the recall session. Tacrine treatment at a dose of 40 micro mol/kg caused a significant increase in serum alanine aminotransferase activity in 17- and 30-day-old mice at 6 h post-dosing, with the extent of stimulation in 30-day-old mice being more prominent. In conclusion, tacrine was more potent in enhancing/disrupting the cognitive function, inhibiting locomotor activity as well as in causing hepatotoxicity in 17-day-old than in 30-day-old mice.
Stomach Cancer Risk After Treatment for Hodgkin Lymphoma
Morton, Lindsay M.; Dores, Graça M.; Curtis, Rochelle E.; Lynch, Charles F.; Stovall, Marilyn; Hall, Per; Gilbert, Ethel S.; Hodgson, David C.; Storm, Hans H.; Johannesen, Tom Børge; Smith, Susan A.; Weathers, Rita E.; Andersson, Michael; Fossa, Sophie D.; Hauptmann, Michael; Holowaty, Eric J.; Joensuu, Heikki; Kaijser, Magnus; Kleinerman, Ruth A.; Langmark, Frøydis; Pukkala, Eero; Vaalavirta, Leila; van den Belt-Dusebout, Alexandra W.; Fraumeni, Joseph F.; Travis, Lois B.; Aleman, Berthe M.; van Leeuwen, Flora E.
2013-01-01
Purpose Treatment-related stomach cancer is an important cause of morbidity and mortality among the growing number of Hodgkin lymphoma (HL) survivors, but risks associated with specific HL treatments are unclear. Patients and Methods We conducted an international case-control study of stomach cancer nested in a cohort of 19,882 HL survivors diagnosed from 1953 to 2003, including 89 cases and 190 matched controls. For each patient, we quantified cumulative doses of specific alkylating agents (AAs) and reconstructed radiation dose to the stomach tumor location. Results Stomach cancer risk increased with increasing radiation dose to the stomach (Ptrend < .001) and with increasing number of AA-containing chemotherapy cycles (Ptrend = .02). Patients who received both radiation to the stomach ≥ 25 Gy and high-dose procarbazine (≥ 5,600 mg/m2) had strikingly elevated stomach cancer risk (25 cases, two controls; odds ratio [OR], 77.5; 95% CI, 14.7 to 1452) compared with those who received radiation < 25 Gy and procarbazine < 5,600 mg/m2 (Pinteraction < .001). Risk was also elevated (OR, 2.8; 95% CI, 1.3 to 6.4) among patients who received radiation to the stomach ≥ 25 Gy but procarbazine < 5,600 mg/m2; however, no procarbazine-related risk was evident with radiation < 25 Gy. Treatment with dacarbazine also increased stomach cancer risk (12 cases, nine controls; OR, 8.8; 95% CI, 2.1 to 46.6), after adjustment for radiation and procarbazine doses. Conclusion Patients with HL who received subdiaphragmatic radiotherapy had dose-dependent increased risk of stomach cancer, with marked risks for patients who also received chemotherapy containing high-dose procarbazine. For current patients, risks and benefits of exposure to both procarbazine and subdiaphragmatic radiotherapy should be weighed carefully. For patients treated previously, GI symptoms should be evaluated promptly. PMID:23980092
Larsen, Inge; Hjulsager, Charlotte Kristiane; Holm, Anders; Olsen, John Elmerdahl; Nielsen, Søren Saxmose; Nielsen, Jens Peter
2016-01-01
Oral treatment with antimicrobials is widely used in pig production for the control of gastrointestinal infections. Lawsonia intracellularis (LI) causes enteritis in pigs older than six weeks of age and is commonly treated with antimicrobials. The objective of this study was to evaluate the efficacy of three oral dosage regimens (5, 10 and 20mg/kg body weight) of oxytetracycline (OTC) in drinking water over a five-day period on diarrhoea, faecal shedding of LI and average daily weight gain (ADG). A randomised clinical trial was carried out in four Danish pig herds. In total, 539 animals from 37 batches of nursery pigs were included in the study. The dosage regimens were randomly allocated to each batch and initiated at presence of assumed LI-related diarrhoea. In general, all OTC doses used for the treatment of LI infection resulted in reduced diarrhoea and LI shedding after treatment. Treatment with a low dose of 5mg/kg OTC per kg body weight, however, tended to cause more watery faeces and resulted in higher odds of pigs shedding LI above detection level when compared to medium and high doses (with odds ratios of 5.5 and 8.4, respectively). No association was found between the dose of OTC and the ADG. In conclusion, a dose of 5mg OTC per kg body weight was adequate for reducing the high-level LI shedding associated with enteropathy, but a dose of 10mg OTC per kg body weight was necessary to obtain a maximum reduction in LI shedding. Copyright © 2015 Elsevier B.V. All rights reserved.
Vitamin E reduces hepatic fibrosis in mice with Schistosoma japonicum infection.
Wang, Xuefeng; Zhang, Rongbo; Du, Jiuwei; Hu, Youying; Xu, Lifa; Lu, Jun; Ye, Song
2012-02-01
To investigate whether vitamin E protects against hepatic fibrosis in mice with Schistosoma japonicum infection, 24 pathogen-free Kunming mice were selected and randomly divided into four groups: control (uninfected, untreated), model (infected, untreated), low-dose intervention (infected, vitamin E-treated, 30 mg/g bodyweight/day) and high-dose intervention (infected, vitamin E-treated, 60 mg/g bodyweight/day). Mice were infected with Schistosoma japonicum by inoculating abdominal skin with snail hosts. The activities of malondialdehyde (MDA), superoxide dismutase (SOD), glutathione peroxidase (GPx) and catalase (CAT) were detected in hepatic tissue by colorimetry. The expression levels of laminin (LN), hyaluronic acid (HA), procollagen type Ⅲ (PC-III) and type Ⅳ collagen (IV-C) were detected in the serum by radioimmunoassay. Finally, areas and numbers of granulomas were assessed through histopathology 42 days following treatment. The results revealed that mean areas of granulomas were smaller in the low- and high-dose intervention groups compared to those in the model group. Furthermore, the higher dose of vitamin E resulted in smaller granulomas than the low dose. The levels of LN, HA, PC-III and IV-C in the serum were lower following vitamin E treatment than in the model group. By contrast, activity of SOD, GPx and CAT in hepatic tissue was higher following vitamin E treatment compared to the model group. The activity of MDA was lower in hepatic tissue following vitamin E treatment compared to the model group, but was higher compared to controls. In general, the higher dose of vitamin E affected measurements to a greater extent than the lower dose. In conclusion, vitamin E treatment may reduce the growth of granulomas, slowing the process of hepatic fibrosis, and this effect may be the result of the altered activity of the oxidation-reduction enzyme system.
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A; Zhang, Zhigang; Schmitt, Adam M; Higginson, Daniel S; Lis, Eric; Zelefsky, Michael J; Mechalakos, James; Bilsky, Mark H
2017-01-01
OBJECTIVE An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. METHODS All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3-6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor's histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. RESULTS A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2-141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7-57 months). The median prescribed dose was 2400 cGy (range 1600-2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). CONCLUSIONS High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes.
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A.; Zhang, Zhigang; Schmitt, Adam M.; Higginson, Daniel S.; Lis, Eric; Zelefsky, Michael J.; Mechalakos, James; Bilsky, Mark H.
2017-01-01
Objective An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. Methods All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3–6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor’s histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. Results A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2–141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7–57 months). The median prescribed dose was 2400 cGy (range 1600–2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). Conclusions High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes. PMID:28041329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, J; Lindsay, P; University of Toronto, Toronto
Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mmmore » circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations. Funding Support: this work is supported by funding the National Sciences and Engineering Research Council of Canada, and a Mitacs-accelerate fellowship. Conflict of Interest: Dr. Lindsay and Dr. Jaffray are listed as inventors of the small animal microirradiator described herein. This system has been licensed for commercial development.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dellamonica, D.; Luo, G.; Ding, G.
Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less
Low-Dose Radiation Potentiates the Therapeutic Efficacy of Folate Receptor-Targeted Hapten Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sega, Emanuela I.; Lu Yingjuan; Ringor, Michael
2008-06-01
Purpose: Human cancers frequently overexpress a high-affinity cell-surface receptor for the vitamin folic acid. Highly immunogenic haptens can be targeted to folate receptor-expressing cell surfaces by administration of folate-hapten conjugates, rendering the decorated tumor cell surfaces more recognizable by the immune system. Treatment of antihapten-immunized mice with folate-hapten constructs results in elimination of moderately sized tumors by the immune system. However, when subcutaneous tumors exceed 300 mm{sup 3} before initiation of therapy, antitumor activity is significantly decreased. In an effort to enhance the efficacy of folate-targeted hapten immunotherapy (FTHI) against large tumors, we explored the combination of targeted hapten immunotherapymore » with low-dose radiotherapy. Methods and Materials: Mice bearing 300-mm{sup 3} subcutaneous tumors were treated concurrently with FTHI (500 nmol/kg of folate conjugated to fluorescein isothiocyanate, 20,000 U/dose of interleukin 2, and 25,000 U/dose of interferon {alpha}) and low-dose radiotherapy (3 Gy/dose focused directly on the desired tumor mass). The efficacy of therapy was evaluated by measuring tumor volume. Results: Tumor growth analyses show that radiotherapy synergizes with FTHI in antihapten-immunized mice, thereby allowing for cures of animals bearing tumors greater than 300 mm{sup 3}. More importantly, nonirradiated distal tumor masses in animals containing locally irradiated tumors also showed improved response to hapten immunotherapy, suggesting that not all tumor lesions must be identified and irradiated to benefit from the combination therapy. Conclusions: These results suggest that simultaneous treatment with FTHI and radiation therapy can enhance systemic antitumor activity in tumor-bearing mice.« less
SU-F-P-49: Comparison of Mapcheck 2 Commission for Photon and Electron Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, J; Yang, C; Morris, B
2016-06-15
Purpose: We will investigate the performance variation of the MapCheck2 detector array with different array calibration and dose calibration pairs from different radiation therapy machine. Methods: A MapCheck2 detector array was calibrated on 3 Elekta accelerators with different energy of photon (6 MV, 10 MV, 15 MV and 18 MV) and electron (6 MeV, 9 MeV, 12 MeV, 15 MeV, 18 MeV and 20 MeV) beams. Dose calibration was conducted by referring a water phantom measurement following TG-51 protocol and commission data for each accelerator. A 10 cm × 10 cm beam was measured. This measured map was morphed bymore » applying different calibration pairs. Then the difference was quantified by comparing the doses and similarity using gamma analysis of criteria (0.5 %, 0 mm). Profile variation was evaluated on a same dataset with different calibration pairs. The passing rate of an IMRT QA planar dose was calculated by using 3 mm and 3% criteria and compared with respect to each calibration pairs. Results: In this study, a dose variation up to 0.67% for matched photons and 1.0% for electron beams is observed. Differences of flatness and symmetry can be as high as 1% and 0.7% respectively. Gamma analysis shows a passing rate ranging from 34% to 85% for the standard 10 × 10 cm field. Conclusion: Our work demonstrated that a customized array calibration and dose calibration for each machine is preferred to fulfill a high standard patient QA task.« less
Kanbak, Güngör; Uzuner, Kubilay; Kuşat Ol, Kevser; Oğlakçı, Ayşegül; Kartkaya, Kazım; Şentürk, Hakan
2014-01-01
Abstract We aim to study the effect of low-dose aspirin and kefir on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet. Forty adult male Sprague-Dawley rats were divided into five groups: control, high-salt (HS) (8.0% NaCl), HS+aspirin (10 mg/kg), HS+kefir (10.0%w/v), HS+aspirin +kefir. We measured sistolic blood pressure (SBP), mean arterial pressure (MAP), diastolic pressure, pulse pressure in the rats. Cathepsin B, L, DNA fragmentation and caspase-3 activities were determined from rat kidney tissues and rats clearance of creatinine calculated. Although HS diet increased significantly SBP, MAP, diastolic pressure, pulse pressure parameters compared the control values. They were not as high as accepted hypertension levels. When compared to HS groups, kefir groups significantly decrease Cathepsin B and DNA fragmentation levels. Caspase levels were elevated slightly in other groups according to control group. While, we also found that creatinine clearance was higher in HS+kefir and HS+low-dose aspirin than HS group. Thus, using low-dose aspirin had been approximately decreased of renal function damage. Kefir decreased renal function damage playing as Angiotensin-converting enzyme inhibitor. But, low-dose aspirin together with kefir worsened rat renal function damage. Cathepsin B might play role both apoptosis and prorenin-processing enzyme. But not caspase pathway may be involved in the present HS diet induced apoptosis. In conclusion, kefir and low-dose aspirin used independently protect renal function and renal damage induced by HS diet in rats.
Popović, Natalija; Caballero-Bleda, María; Popović, Miroljub
2014-01-01
The effects of scopolamine on memory consolidation are controversial and depend on several factors (i.e. site of administration, time of administration and testing, dose, cognitive task, experimental protocol, specie, strain, etc.). Generally, the range dose of systemic administered scopolamine, used in memory consolidation studies, has varied from 0.05 to 50 mg/kg. However, according to the literature, the most frequently used doses of scopolamine efficient on memory consolidation, are 1 and 30 mg/kg, low and high doses, respectively. In open field habituation studies only lower doses of scopolamine were used to test memory consolidation. Therefore, in the present study we compared the effects of low (1 mg/kg) and high (30 mg/kg) scopolamine dose, on the open field habituation task, in male Wistar rats. Scopolamine was administered immediately after the acquisition task and animals were retested 48 h later on. On the retested day, the ambulation and rearing in the open field decreased in the same manner in all tested groups. In saline- and 1 mg/kg scopolamine-treated animals, the time spent in grooming significantly decreased in the habituation task, while the same parameter significantly increased in animals treated with 30 mg/kg of scopolamine. The defecation rate significantly decreased (control group), maintained (1 mg/kg of scopolamine treated animals) or significantly increased (30 mg/kg of scopolamine treated group) on retention test. In conclusion, the present data suggest that post-training scopolamine administration does not affect locomotion neither exploration in the habituation to a novel environment, but increases defecation and grooming, two behaviours associated with fearful and stressful situations.
Dimitris, Michelle C; Perumal, Nandita; Craig-Barnes, Hayley A; Leadley, Michael; Mahmud, Abdullah A; Baqui, Abdullah H; Roth, Daniel E
2016-04-01
Vitamin D status is conventionally defined by the serum concentration of 25-hydroxyvitamin D. However, it has been proposed that the serum cholecalciferol concentration (D3) also determines functional vitamin D sufficiency. The objective of this study was to describe the effect of weekly high-dose vitamin D3 supplementation on inter-dose serum D3 in pregnant women. We conducted a sub-study of a completed randomized double-blind placebo-controlled trial of vitamin D3 (35,000 IU/week) supplementation in late pregnancy (AViDD trial) in Dhaka, Bangladesh. This study included pregnant women enrolled at 26-29 weeks gestation who fully adhered to the prenatal supplement intervention for ≥8 consecutive weeks and for whom serum samples were available for D3 analysis (n=65). Serum D3 was uniformly low at enrolment. Mean D3 increased and was maximal at 1 day after vitamin D dose administration (152.09nmol/L, SD 25.11nmol/L) and remained significantly higher in VitD vs. Pl at 7 days (29.59nmol/L vs. 1.92nmol/L, p=0.007). Daily average of the group mean D3 during the week following dosing was 66.97nmol/L in VitD versus 2.13nmol/L in Pl. In conclusion, serum D3 remained significantly elevated throughout the week following ≥8 consecutive weekly doses of 35,000 IU D3 in pregnant women. However, the clinically significant minimum threshold of serum D3 remains to be established. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hansen, Karen E.; Johnson, R. Erin; Chambers, Kaitlin R.; Johnson, Michael G.; Lemon, Christina C.; Thuy Vo, Tien Nguyen; Marvdashti, Sheeva
2015-01-01
Importance Experts debate optimal 25(OH)D levels for musculoskeletal health. Objective To compare effects of placebo, low-dose and high-dose vitamin D on one-year changes in total fractional calcium absorption, bone mineral density, Timed-Up-and-Go and 5-sit-to-stand tests and muscle mass in postmenopausal women with vitamin D insufficiency. Design Randomized, double-blind, placebo-controlled, clinical trial conducted from May 2010 to August 2014. Setting Single-center trial conducted in Madison, Wisconsin. Participants 230 postmenopausal women ≤75 years old with baseline 25(OH)D levels 14-27 ng/mL and no osteoporosis. Intervention Three arms included daily white and twice monthly yellow placebo (n=76), daily 800 IU vitamin D3 and twice monthly yellow placebo (n=76), and daily white placebo and twice monthly 50,000 IU vitamin D3 (n=79). The high-dose vitamin D regimen achieved and maintained 25(OH)D levels ≥30 ng/mL. Main Outcome Measures One year change in total fractional calcium absorption using two stable isotopes, bone mineral density and muscle mass using dual energy x-ray absorptiometry, Timed-Up-and-Go and 5-Sit-to-Stand tests, functional status (Health Assessment Questionnaire) and physical activity (Physical Activity Scale for the Elderly), with Benjamini-Hochberg correction of p-values to control the false discovery rate. Results After controlling for baseline absorption, calcium absorption increased 1% (10 mg/day) in the high-dose arm, but decreased by 2% in low-dose (p=0.005 vs. high-dose) and by 1.3% placebo (p=0.03 vs. high-dose) arms. We found no between-arm changes in spine, mean total hip, mean femoral neck or total body bone mineral density, trabecular bone score, muscle mass, 5-sit-to-stand or Timed-Up-and-Go test scores. Likewise, we found no between-arm differences for numbers of falls, number of fallers, physical activity or functional status. Conclusion and Relevance High-dose vitamin D therapy increased calcium absorption, but the effect was small and did not translate into beneficial effects on bone mineral density, muscle function, muscle mass or falls. We found no data to support experts’ recommendations to maintain serum 25(OH)D levels ≥30 ng/mL in postmenopausal women. Instead, we found that low and high-dose vitamin D were equivalent to placebo, in their effects on bone and muscle outcomes in this cohort of postmenopausal women with 25(OH)D levels <30 ng/mL. ClinicalTrials.gov.Identifier:NCT00933244 PMID:26237520
SU-E-T-344: Validation and Clinical Experience of Eclipse Electron Monte Carlo Algorithm (EMC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokharel, S; Rana, S
2014-06-01
Purpose: The purpose of this study is to validate Eclipse Electron Monte Carlo (Algorithm for routine clinical uses. Methods: The PTW inhomogeneity phantom (T40037) with different combination of heterogeneous slabs has been CT-scanned with Philips Brilliance 16 slice scanner. The phantom contains blocks of Rando Alderson materials mimicking lung, Polystyrene (Tissue), PTFE (Bone) and PMAA. The phantom has 30×30×2.5 cm base plate with 2cm recesses to insert inhomogeneity. The detector systems used in this study are diode, tlds and Gafchromic EBT2 films. The diode and tlds were included in CT scans. The CT sets are transferred to Eclipse treatment planningmore » system. Several plans have been created with Eclipse Monte Carlo (EMC) algorithm 11.0.21. Measurements have been carried out in Varian TrueBeam machine for energy from 6–22mev. Results: The measured and calculated doses agreed very well for tissue like media. The agreement was reasonably okay for the presence of lung inhomogeneity. The point dose agreement was within 3.5% and Gamma passing rate at 3%/3mm was greater than 93% except for 6Mev(85%). The disagreement can reach as high as 10% in the presence of bone inhomogeneity. This is due to eclipse reporting dose to the medium as opposed to the dose to the water as in conventional calculation engines. Conclusion: Care must be taken when using Varian Eclipse EMC algorithm for dose calculation for routine clinical uses. The algorithm dose not report dose to water in which most of the clinical experiences are based on rather it just reports dose to medium directly. In the presence of inhomogeneity such as bone, the dose discrepancy can be as high as 10% or even more depending on the location of normalization point or volume. As Radiation oncology as an empirical science, care must be taken before using EMC reported monitor units for clinical uses.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugano, Yasutaka; Mizuta, Masahiro; Takao, Seishin
Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of themore » tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nowik, P; Bujila, R; Merzan, D
2015-06-15
Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CTmore » dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.« less
Radioadaptive Cytoprotective Pathways in the Mouse Retina
NASA Technical Reports Server (NTRS)
Zanello, Susana B.; Wotring, V.; Theriot, C.; Ploutz-Snyder, R.; Zhang, Y.; Wu, H.
2010-01-01
Exposure to cosmic radiation implies a risk of tissue degeneration. Radiation retinopathy is a complication of radiotherapy and exhibits common features with other retinopathies and neuropathies. Exposure to a low radiation dose elicits protective cellular events (radioadaptive response), reducing the stress of a subsequent higher dose. To assess the risk of radiation-induced retinal changes and the extent to which a small priming dose reduces this risk, we used a mouse model exposed to a source of Cs-137-gamma radiation. Gene expression profiling of retinas from non-irradiated control C57BL/6J mice (C) were compared to retinas from mice treated with a low 50 mGy dose (LD), a high 6 Gy dose (HD), and a combined treatment of 50 mGy (priming) and 6 Gy (challenge) doses (LHD). Whole retina RNA was isolated and expression analysis for selected genes performed by RTqPCR. Relevant target genes associated with cell death/survival, oxidative stress, cellular stress response and inflammation pathways, were analyzed. Cellular stress response genes were upregulated at 4 hr after the challenge dose in LHD retinas (Sirt1: 1.5 fold, Hsf1: 1.7 fold, Hspa1a: 2.5 fold; Hif1a: 1.8 fold, Bag1: 1.7). A similar trend was observed in LD animals. Most antioxidant enzymes (Hmox1, Sod2, Prdx1, Cygb, Cat1) and inflammatory mediators (NF B, Ptgs2 and Tgfb1) were upregulated in LHD and LD retinas. Expression of the pro-survival gene Bcl2 was upregulated in LD (6-fold) and LHD (4-fold) retinas. In conclusion, cytoprotective gene networks activation in the retina suggests a radioadaptive response to a priming irradiation dose, with mitigation of the deleterious effects of a subsequent high dose exposure. The enhancement of these cytoprotective mechanisms has potential value as a countermeasure to ocular alterations caused by radiation alone or in combination with other factors in spaceflight environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Touch, M; Duke University Medical Center, Durham, NC; Wu, Q
2014-06-01
Purpose: To demonstrate an embedded tissue equivalent presage dosimeter for measuring 3D doses in moving tumors and to study the interplay effect between the tumor motion and intensity modulation in hypofractioned Volumetric Modulated Arc Therapy(VMAT) lung treatment. Methods: Motion experiments were performed using cylindrical Presage dosimeters (5cm diameter by 7cm length) mounted inside the lung insert of a CIRS thorax phantom. Two different VMAT treatment plans were created and delivered in three different scenarios with the same prescribed dose of 18 Gy. Plan1, containing a 2 centimeter spherical CTV with an additional 2mm setup margin, was delivered on a stationarymore » phantom. Plan2 used the same CTV except expanded by 1 cm in the Sup-Inf direction to generate ITV and PTV respectively. The dosimeters were irradiated in static and variable motion scenarios on a Truebeam system. After irradiation, high resolution 3D dosimetry was performed using the Duke Large Field-of-view Optical-CT Scanner, and compared to the calculated dose from Eclipse. Results: In the control case (no motion), good agreement was observed between the planned and delivered dose distributions as indicated by 100% 3D Gamma (3% of maximum planned dose and 3mm DTA) passing rates in the CTV. In motion cases gamma passing rates was 99% in CTV. DVH comparisons also showed good agreement between the planned and delivered dose in CTV for both control and motion cases. However, differences of 15% and 5% in dose to PTV were observed in the motion and control cases respectively. Conclusion: With very high dose nature of a hypofraction treatment, significant effect was observed only motion is introduced to the target. This can be resulted from the motion of the moving target and the modulation of the MLC. 3D optical dosimetry can be of great advantage in hypofraction treatment dose validation studies.« less
Directional interstitial brachytherapy from simulation to application
NASA Astrophysics Data System (ADS)
Lin, Liyong
Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the design optimization and construction of the first prototype directional source. Potential clinical applications and potential benefits of directional sources have been shown for prostate and breast tumors.
TU-D-201-07: Severity Indication in High Dose Rate Brachytherapy Emergency Response Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K; Rustad, F
Purpose: Understanding the corresponding dose to different staff during the High Dose Rate (HDR) Brachytherapy emergency response procedure could help to develop a strategy in efficiency and effective action. In this study, the variation and risk analysis methodology was developed to simulation the HDR emergency response procedure based on severity indicator. Methods: A GammaMedplus iX HDR unit from Varian Medical System was used for this simulation. The emergency response procedure was decomposed based on risk management methods. Severity indexes were used to identify the impact of a risk occurrence on the step including dose to patient and dose to operationmore » staff by varying the time, HDR source activity, distance from the source to patient and staff and the actions. These actions in 7 steps were to press the interrupt button, press emergency shutoff switch, press emergency button on the afterloader keypad, turn emergency hand-crank, remove applicator from the patient, disconnect transfer tube and move afterloader from the patient, and execute emergency surgical recovery. Results: Given the accumulated time in second at the assumed 7 steps were 15, 5, 30, 15, 180, 120, 1800, and the dose rate of HDR source is 10 Ci, the accumulated dose in cGy to patient at 1cm distance were 188, 250, 625, 813, 3063, 4563 and 27063, and the accumulated exposure in rem to operator at outside the vault, 1m and 10cm distance were 0.0, 0.0, 0.1, 0.1, 22.6, 37.6 and 262.6. The variation was determined by the operators in action at different time and distance from the HDR source. Conclusion: The time and dose were estimated for a HDR unit emergency response procedure. It provided information in making optimal decision during the emergency procedure. Further investigation would be to optimize and standardize the responses for other emergency procedure by time-spatial-dose severity function.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pedicini, Piernicola, E-mail: ppiern@libero.it; Caivano, Rocchina; Fiorentino, Alba
2012-01-01
To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose onmore » PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d{sub 2cc}, d{sub 1cc}, and d{sub max} (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, G; Ahunbay, E; Li, X
Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and consideringmore » patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.« less
Ehrlich, Allison K; Pennington, Jamie M; Bisson, William H; Kolluri, Siva K; Kerkvliet, Nancy I
2018-02-01
FICZ and TCDD, two high-affinity AhR ligands, are reported to have opposite effects on T cell differentiation with TCDD inducing regulatory T cells and FICZ inducing Th17 cells. This dichotomy has been attributed to ligand-intrinsic differences in AhR activation, although differences in sensitivity to metabolism complicate the issue. TCDD is resistant to AhR-induced metabolism and produces sustained AhR activation following a single dose in the μg/kg range, whereas FICZ is rapidly metabolized and AhR activation is transient. Nonetheless, prior studies comparing FICZ with TCDD have generally used the same 10-50 μg/kg dose range, and thus the two ligands would not equivalently activate AhR. We hypothesized that high-affinity AhR ligands can promote CD4+ T cell differentiation into both Th17 cells and Tregs, with fate depending on the extent and duration of AhR activation. We compared the immunosuppressive effects of TCDD and FICZ, along with two other rapidly metabolized ligands (ITE and 11-Cl-BBQ) in an acute alloresponse mouse model. The dose and timing of administration of each ligand was optimized for TCDD-equivalent Cyp1a1 induction. When optimized, all of the ligands suppressed the alloresponse in conjunction with the induction of Foxp3- Tr1 cells on day 2 and the expansion of natural Foxp3+ Tregs on day 10. In contrast, a low dose of FICZ induced transient expression of Cyp1a1 and did not induce Tregs or suppress the alloresponse but enhanced IL-17 production. Interestingly, low doses of the other ligands, including TCDD, also increased IL-17 production on day 10. These findings support the conclusion that the dose and the duration of AhR activation by high-affinity AhR ligands are the primary factors driving the fate of T cell differentiation. © The Author 2017. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Long-Term Safety and Efficacy of Factor IX Gene Therapy in Hemophilia B
Nathwani, A.C.; Reiss, U.M.; Tuddenham, E.G.D.; Rosales, C.; Chowdary, P.; McIntosh, J.; Della Peruta, M.; Lheriteau, E.; Patel, N.; Raj, D.; Riddell, A.; Pie, J.; Rangarajan, S.; Bevan, D.; Recht, M.; Shen, Y.-M.; Halka, K.G.; Basner-Tschakarjan, E.; Mingozzi, F.; High, K.A.; Allay, J.; Kay, M.A.; Ng, C.Y.C.; Zhou, J.; Cancio, M.; Morton, C.L.; Gray, J.T.; Srivastava, D.; Nienhuis, A.W.; Davidoff, A.M.
2014-01-01
BACKGROUND In patients with severe hemophilia B, gene therapy that is mediated by a novel self-complementary adeno-associated virus serotype 8 (AAV8) vector has been shown to raise factor IX levels for periods of up to 16 months. We wanted to determine the durability of transgene expression, the vector dose–response relationship, and the level of persistent or late toxicity. METHODS We evaluated the stability of transgene expression and long-term safety in 10 patients with severe hemophilia B: 6 patients who had been enrolled in an initial phase 1 dose-escalation trial, with 2 patients each receiving a low, intermediate, or high dose, and 4 additional patients who received the high dose (2×1012 vector genomes per kilogram of body weight). The patients subsequently underwent extensive clinical and laboratory monitoring. RESULTS A single intravenous infusion of vector in all 10 patients with severe hemophilia B resulted in a dose-dependent increase in circulating factor IX to a level that was 1 to 6% of the normal value over a median period of 3.2 years, with observation ongoing. In the high-dose group, a consistent increase in the factor IX level to a mean (±SD) of 5.1±1.7% was observed in all 6 patients, which resulted in a reduction of more than 90% in both bleeding episodes and the use of prophylactic factor IX concentrate. A transient increase in the mean alanine aminotransferase level to 86 IU per liter (range, 36 to 202) occurred between week 7 and week 10 in 4 of the 6 patients in the high-dose group but resolved over a median of 5 days (range, 2 to 35) after prednisolone treatment. CONCLUSIONS In 10 patients with severe hemophilia B, the infusion of a single dose of AAV8 vector resulted in long-term therapeutic factor IX expression associated with clinical improvement. With a follow-up period of up to 3 years, no late toxic effects from the therapy were reported. (Funded by the National Heart, Lung, and Blood Institute and others; ClinicalTrials.gov number, NCT00979238.) PMID:25409372
ESTIMATING SYSTEMIC EXPOSURE TO ETHINYL ESTRADIOL FROM AN ORAL CONTRACEPTIVE
WESTHOFF, Carolyn L.; PIKE, Malcolm C.; TANG, Rosalind; DINAPOLI, Marianne N.; SULL, Monica; CREMERS, Serge
2015-01-01
Objectives This study was conducted to compare single-dose pharmacokinetics of ethinyl estradiol in an oral contraceptive to steady-state values, and to assess whether any simpler measures could provide an adequate proxy of the ‘gold standard’ 24-hour steady-state area-under-the-curve. Identifying a simple, less expensive, measure of systemic ethinyl estradiol exposure would be useful for larger studies designed to assess the relationship between an individual’s ethinyl estradiol exposure and her side effects. Study Design We conducted a 13 samples over 24 hours pharmacokinetic analysis on day 1 and day 21 of the first cycle of a monophasic oral contraceptive containing 30 mcg ethinyl estradiol and 150 mcg levonorgestrel in 17 non-obese healthy white women. We also conducted an abbreviated single dose 9-sample pharmacokinetic analysis after a month washout. Ethinyl estradiol was measured by liquid chromatography-tandem mass spectrometry. We compared results of full 13-sample steady-state pharmacokinetic analysis with results calculated using fewer samples (9 or 5) and following the single doses. We calculated Pearson correlation coefficients to evaluate the relationships between these estimates of systemic ethinyl estradiol exposure. Results The area-under-the-curve, maximum (Cmax), and 24-hour (C24) values were similar following the two single oral contraceptive doses (area-under-the-curve, r = 0.92). The steady-state 13-sample 24-hour area-under-the-curve was highly correlated with the average 9-sample area-under-the-curve after the two single doses (r = 0.81, p = 0.0002). This correlation remained the same if the number of samples was reduced to 4, taken at time 1, 2.5, 4 and 24 hours. The C24 at steady-state was highly correlated with the 24-hour steady-state area-under-the-curve (r = 0.92, p < 0.0001). The average of the C24 values following the two single doses was also quite highly correlated with the steady-state area-under-the-curve (r = 0.72, p = 0.0026). Conclusions Limited blood sampling, including results from two single doses, gave highly correlated estimates of an oral contraceptive user’s steady-state ethinyl estradiol exposure. PMID:25511238
Chu, Bae P.; Horan, Christopher; Basu, Ellen; Dauer, Lawrence; Williamson, Matthew; Carrasquillo, Jorge A.; Pandit-Taskar, Neeta; Modak, Shakeel
2015-01-01
Background Although 131I-metaiodobenzylguanidine therapy (131I-MIBG) is increasingly used for children with high-risk neuroblastoma, a paucity of lead-lined rooms limits its wider use. We implemented radiation safety procedures to comply with New York City Department of Health and Mental Hygiene regulations for therapeutic radioisotopes and administered 131I-MIBG using rolling lead shields. Procedure Patients received 0.67GBq (18mCi)/kg/dose 131I-MIBG on an IRB-approved protocol (NCT00107289). Radiation safety procedures included private room with installation of rolling lead shields to maintain area dose rates ≤0.02mSv/h outside the room, patient isolation until dose rate <0.07mSv/h at 1m and retention of a urinary catheter with collection of urine in lead boxes. Parents were permitted in the patient’s room behind lead shields, trained in radiation safety principles and given real-time radiation monitors. Results Records on 16 131I-MIBG infusions among 10 patients (age 2–11 years) were reviewed. Mean ± standard deviation 131I-MIBG administered was 17.67±11.14 (range: 6.11–40.59) GBq. Mean maximum dose rates outside treatment rooms were 0.013±0.008 mSv/hr. Median time-to-discharge was 3 days post-131I-MIBG. Exposure of medical staff and parents was below regulatory limits. Cumulative whole-body dose received by the physician, nurse and radiation safety officer during treatment was 0.098±0.058, 0.056±0.045, 0.055±0.050 mSv respectively. Cumulative exposure to parents was 0.978±0.579mSv. Estimated annual radiation exposure for inpatient nurses was 0.096±0.034mSv/nurse. Thyroid bioassay scans on all medical personnel were
Sievenpiper, John L.; Chiavaroli, Laura; de Souza, Russell J.; Mirrahimi, Arash; Cozma, Adrian I.; Ha, Vanessa; Wang, D. David; Yu, Matthew E.; Carleton, Amanda J.; Beyene, Joseph; Di Buono, Marco; Jenkins, Alexandra L.; Leiter, Lawrence A.; Wolever, Thomas M. S.; Kendall, Cyril W. C.; Jenkins, David J. A.
2012-01-01
Contrary to concerns that fructose may have adverse metabolic effects, there is evidence that small, ‘catalytic’ doses ( ≤ 10 g/meal) of fructose decrease the glycaemic response to high-glycaemic index meals in human subjects. To assess the longer-term effects of ‘catalytic’ doses of fructose, we undertook a meta-analysis of controlled feeding trials. We searched MEDLINE, EMBASE, CINAHL and the Cochrane Library. Analyses included all controlled feeding trials ≥ 7 d featuring ‘catalytic’ fructose doses ( ≤ 36 g/d) in isoenergetic exchange for other carbohydrates. Data were pooled by the generic inverse variance method using random-effects models and expressed as mean differences (MD) with 95 % CI. Heterogeneity was assessed by the Q statistic and quantified by I2. The Heyland Methodological Quality Score assessed study quality. A total of six feeding trials (n 118) met the eligibility criteria. ‘Catalytic’ doses of fructose significantly reduced HbA1c (MD − 0·40, 95 % CI − 0·72, − 0·08) and fasting glucose (MD − 0·25, 95 % CI − 0·44, − 0·07). This benefit was seen in the absence of adverse effects on fasting insulin, body weight, TAG or uric acid. Subgroup and sensitivity analyses showed evidence of effect modification under certain conditions. The small number of trials and their relatively short duration limit the strength of the conclusions. In conclusion, this small meta-analysis shows that ‘catalytic’ fructose doses ( ≤ 36 g/d) may improve glycaemic control without adverse effects on body weight, TAG, insulin and uric acid. There is a need for larger, longer ( ≥ 6 months) trials using ‘catalytic’ fructose to confirm these results. PMID:22354959
Grotenhermen, Franjo; Russo, Ethan; Zuardi, Antonio Waldo
2017-01-01
Abstract This short communication examines the question whether the experimental data presented in a study by Merrick et al. are of clinical relevance. These authors found that cannabidiol (CBD), a major cannabinoid of the cannabis plant devoid of psychotropic effects and of great interest for therapeutic use in several medical conditions, may be converted in gastric fluid into the psychoactive cannabinoids delta-8-THC and delta-9-THC to a relevant degree. They concluded that “the acidic environment during normal gastrointestinal transit can expose orally CBD-treated patients to levels of THC and other psychoactive cannabinoids that may exceed the threshold for a positive physiological response.” They issued a warning concerning oral use of CBD and recommend the development of other delivery methods. However, the available clinical data do not support this conclusion and recommendation, since even high doses of oral CBD do not cause psychological, psychomotor, cognitive, or physical effects that are characteristic for THC or cannabis rich in THC. On the contrary, in the past decades and by several groups, high doses of oral CBD were consistently shown to cause opposite effects to those of THC in clinical studies. In addition, administration of CBD did not result in detectable THC blood concentrations. Thus, there is no reason to avoid oral use of CBD, which has been demonstrated to be a safe means of administration of CBD, even at very high doses. PMID:28861499
Grotenhermen, Franjo; Russo, Ethan; Zuardi, Antonio Waldo
2017-01-01
This short communication examines the question whether the experimental data presented in a study by Merrick et al. are of clinical relevance. These authors found that cannabidiol (CBD), a major cannabinoid of the cannabis plant devoid of psychotropic effects and of great interest for therapeutic use in several medical conditions, may be converted in gastric fluid into the psychoactive cannabinoids delta-8-THC and delta-9-THC to a relevant degree. They concluded that "the acidic environment during normal gastrointestinal transit can expose orally CBD-treated patients to levels of THC and other psychoactive cannabinoids that may exceed the threshold for a positive physiological response." They issued a warning concerning oral use of CBD and recommend the development of other delivery methods. However, the available clinical data do not support this conclusion and recommendation, since even high doses of oral CBD do not cause psychological, psychomotor, cognitive, or physical effects that are characteristic for THC or cannabis rich in THC. On the contrary, in the past decades and by several groups, high doses of oral CBD were consistently shown to cause opposite effects to those of THC in clinical studies. In addition, administration of CBD did not result in detectable THC blood concentrations. Thus, there is no reason to avoid oral use of CBD, which has been demonstrated to be a safe means of administration of CBD, even at very high doses.
Current modeling practice may lead to falsely high benchmark dose estimates.
Ringblom, Joakim; Johanson, Gunnar; Öberg, Mattias
2014-07-01
Benchmark dose (BMD) modeling is increasingly used as the preferred approach to define the point-of-departure for health risk assessment of chemicals. As data are inherently variable, there is always a risk to select a model that defines a lower confidence bound of the BMD (BMDL) that, contrary to expected, exceeds the true BMD. The aim of this study was to investigate how often and under what circumstances such anomalies occur under current modeling practice. Continuous data were generated from a realistic dose-effect curve by Monte Carlo simulations using four dose groups and a set of five different dose placement scenarios, group sizes between 5 and 50 animals and coefficients of variations of 5-15%. The BMD calculations were conducted using nested exponential models, as most BMD software use nested approaches. "Non-protective" BMDLs (higher than true BMD) were frequently observed, in some scenarios reaching 80%. The phenomenon was mainly related to the selection of the non-sigmoidal exponential model (Effect=a·e(b)(·dose)). In conclusion, non-sigmoid models should be used with caution as it may underestimate the risk, illustrating that awareness of the model selection process and sound identification of the point-of-departure is vital for health risk assessment. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Efficacy of alternate day versus daily dosing of rosuvastatin
Dulay, Daisy; LaHaye, Stephen A; Lahey, Karen A; Day, Andrew G
2009-01-01
BACKGROUND: Compared with other statins, rosuvastatin has a relatively long half-life, which may allow for the administration of this medication on an alternate day basis. OBJECTIVE: To compare the efficacy of administering rosuvastatin on a daily basis versus on an alternate day basis for the treatment of dyslipidemia. METHODS: In the present crossover study, 45 patients with documented hypercholesterolemia requiring pharmacotherapy were administered either 20 mg of rosuvastatin on alternate days or 10 mg of rosuvastatin daily for six weeks. After a four-week washout period, patients were then switched to the other regimen for another six weeks. The primary end point was the percentage reduction of low-density lipoprotein cholesterol (LDL-C). RESULTS: LDL-C decreased by 48.5% versus 40.9% with daily and alternate day dosing, respectively. This represented an additional absolute reduction of LDL-C of 7.6% (95% CI 1.8% to 13.4%, P=0.012) with the daily dosing regimen. Both dosing regimens provided similar improvements in high-density lipoprotein cholesterol and triglycerides. CONCLUSIONS: Compared with alternate day dosing, daily dosing of rosuvastatin provides a statistically significant advantage in LDL-C reduction. However, the alternate day regimen may be a viable option for those patients in whom cost is a limitation to compliance. PMID:19214297
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merchant, Thomas E.; Kiehna, Erin N.; Li Chenghong
2006-05-01
Purpose: Model the effects of radiation dosimetry on IQ among pediatric patients with central nervous system (CNS) tumors. Methods and Materials: Pediatric patients with CNS embryonal tumors (n = 39) were prospectively evaluated with serial cognitive testing, before and after treatment with postoperative, risk-adapted craniospinal irradiation (CSI) and conformal primary-site irradiation, followed by chemotherapy. Differential dose-volume data for 5 brain volumes (total brain, supratentorial brain, infratentorial brain, and left and right temporal lobes) were correlated with IQ after surgery and at follow-up by use of linear regression. Results: When the dose distribution was partitioned into 2 levels, both had amore » significantly negative effect on longitudinal IQ across all 5 brain volumes. When the dose distribution was partitioned into 3 levels (low, medium, and high), exposure to the supratentorial brain appeared to have the most significant impact. For most models, each Gy of exposure had a similar effect on IQ decline, regardless of dose level. Conclusions: Our results suggest that radiation dosimetry data from 5 brain volumes can be used to predict decline in longitudinal IQ. Despite measures to reduce radiation dose and treatment volume, the volume that receives the highest dose continues to have the greatest effect, which supports current volume-reduction efforts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hung, Jennifer; Shen Sui; De Los Santos, Jennifer F.
2012-07-01
Purpose: To investigate the dosimetric effects of bladder filling on organs at risk (OARs) using three-dimensional image-based treatment planning for vaginal cylinder brachytherapy. Methods and Materials: Twelve patients with endometrial or cervical cancer underwent postoperative high-dose rate vaginal cylinder brachytherapy. For three-dimensional planning, patients were simulated by computed tomography with an indwelling catheter in place (empty bladder) and with 180 mL of sterile water instilled into the bladder (full bladder). The bladder, rectum, sigmoid, and small bowel (OARs) were contoured, and a prescription dose was generated for 10 to 35 Gy in 2 to 5 fractions at the surface ormore » at 5 mm depth. For each OAR, the volume dose was defined by use of two different criteria: the minimum dose value in a 2.0-cc volume receiving the highest dose (D{sub 2cc}) and the dose received by 50% of the OAR volume (D{sub 50%}). International Commission on Radiation Units and Measurements (ICRU) bladder and rectum point doses were calculated for comparison. The cylinder-to-bowel distance was measured using the shortest distance from the cylinder apex to the contoured sigmoid or small bowel. Statistical analyses were performed with paired t tests. Results: Mean bladder and rectum D{sub 2cc} values were lower than their respective ICRU doses. However, differences between D{sub 2cc} and ICRU doses were small. Empty vs. full bladder did not significantly affect the mean cylinder-to-bowel distance (0.72 vs. 0.92 cm, p = 0.08). In contrast, bladder distention had appreciable effects on bladder and small bowel volume dosimetry. With a full bladder, the mean small bowel D{sub 2cc} significantly decreased from 677 to 408 cGy (p = 0.004); the mean bladder D{sub 2cc} did not increase significantly (1,179 cGy vs. 1,246 cGy, p = 0.11). Bladder distention decreased the mean D{sub 50%} for both the bladder (441 vs. 279 cGy, p = 0.001) and the small bowel (168 vs. 132 cGy, p = 0.001). Rectum and sigmoid volume doses were not affected by bladder filling. Conclusions: In high-dose rate vaginal cylinder brachytherapy, treatment with a distended bladder preferentially reduces high dose to the small bowel around the vaginal cuff without a significant change in dose to the bladder, rectum, or sigmoid.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podszun, Maren C.; Grebenstein, Nadine; Hofmann, Ute
It has been hypothesized in the literature that intake of high-dosage vitamin E supplements might alter the expression of cytochrome P{sub 450} enzymes (CYP), particularly CYP3A4, which may lead to adverse nutrient–drug interactions. Because previously published studies reported conflicting findings, we investigated the pharmacodynamics of the lipid-lowering drug atorvastatin (ATV), a CYP3A4 substrate, in response to high-dose α-tocopherol (αT) feeding and determined protein expression and activities of relevant CYP. Groups of ten female Dunkin–Hartley guinea pigs were fed a control (5% fat) or a high-fat control diet (HFC; 21% fat, 0.15% cholesterol) or the HFC diet fortified with αT (250more » mg/kg diet), ATV (300 mg/kg diet) or both ATV + αT for 6 weeks. Relative to control, HFC animals had increased serum cholesterol concentrations, which were significantly reduced by ATV. High-dose αT feeding in combination with ATV (ATV + αT), albeit not αT feeding alone (αT), significantly lowered serum cholesterol relative to HFC, but did not alter the cholesterol-lowering activity of the drug compared to the ATV treated guinea pigs. Protein expression of CYP3A4, CYP4F2, CYP20A1 and OATP C was similar in all groups. Accordingly, no differences in plasma concentrations of phase I metabolites of ATV were observed between the ATV and ATV + αT groups. In conclusion, feeding guinea pigs high-doses of αT for 6 weeks did neither alter the hepatic expression of CYP, nor the pharmacodynamics and metabolism of ATV. High-dose αT intake is thus unlikely to change the efficacy of drugs metabolized by CYP enzymes, particularly by CYP3A4. -- Highlights: ► Vitamin E-atorvastatin interactions were studied in hypercholesterolemic guinea pigs. ► High-dose α-tocopherol did not alter the lipid-lowering efficacy of atorvastatin. ► α-Tocopherol did not change the expression of CYP3A4, CYP4F2, CYP20A or OATP C. ► α-Tocopherol did not affect phase I metabolism of atorvastatin. ► Vitamin E does not change atorvastatin pharmacodynamics or toxicity in guinea pigs.« less
Berkó, Szilvia; Szűcs, Kálmán F; Balázs, Boglárka; Csányi, Erzsébet; Varju, Gábor; Sztojkov-Ivanov, Anita; Budai-Szűcs, Mária; Bóta, Judit; Gáspár, Róbert
2016-01-01
Purpose Transdermal electroporation has become one of the most promising noninvasive methods for drug administration, with greatly increased transport of macromolecules through the skin. The cecal-contracting effects of repeated transdermal electroporation delivery and intravenous administration of neostigmine were compared in anesthetized rats. Methods The cecal contractions were detected with implantable strain gauge sensors, and the plasma levels of neostigmine were followed by high-performance liquid chromatography. Results Both intravenously and EP-administered neostigmine (0.2–66.7 μg/kg) increased the cecal contractions in a dose-dependent manner. For both the low doses and the highest dose, the neostigmine plasma concentrations were the same after the two modes of administration, while an insignificantly higher level was observed at a dose of 20 μg/kg after intravenous administration as compared with the electroporation route. The contractile responses did not differ significantly after the two administration routes. Conclusion The results suggest that electroporation-delivered neostigmine elicits action equivalent to that observed after intravenous administration as concerning both time and intensity. Electroporation permits the delivery of even lower doses of water-soluble compounds through the skin, which is very promising for clinical practice. PMID:27274203
Effects of magnesium sulfate on airway smooth muscle contraction in rats.
Betul Altinisik, Hatice; Kirdemir, Pakize; Altinisik, Ugur; Gokalp, Osman
2016-08-01
Aim To investigate the effect of magnesium sulfate (MgSO4) at different doses on isolated tracheal smooth muscle contraction in rats induced by different mechanisms. Methods Twelve rats' tracheas were placed into organ bath. Consecutively, acetylcholine (10-6,10-5,10-4 M), histamine(10-8,10-5,10-3 M) and KCl (30,60 mM) solutions was administered for contractions. MgSO4 from 10-4 to 10-1 M concentrations were subsequently administered after each constrictive agent and relaxation degrees were recorded. Results In the acetylcholine and KCl groups, dose dependent strong contractions were observed, but not in the histamine group and that group was excluded. Significant relaxation occurred with gradually increasing doses of MgSO4. In the high dose KCl group, a slight increase in contractions after the administration of 10-4 and 10-3 M MgSO4 was recorded. Conclusion We suggest that MgSO4 is effective in relaxing airway smooth muscle contractions caused by different factors; however, it must be considered that low doses of MgSO4 may only lead to a slight increase in contractions. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok
2016-02-01
Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2 g/kg), a single dose of rituximab (375 mg/m), and 4 doses of bortezomib (1.3 mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83 ± 16.0 (14952 ± 5820) and 63 ± 36.0 (10321 ± 7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.
Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok
2016-01-01
Abstract Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate. This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2 g/kg), a single dose of rituximab (375 mg/m2), and 4 doses of bortezomib (1.3 mg/m2). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients. There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83 ± 16.0 (14952 ± 5820) and 63 ± 36.0 (10321 ± 7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468–634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group. In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients. PMID:26844479
Cola beverage and delayed elimination of methotrexate
Santucci, Raoul; Levêque, Dominique; Herbrecht, Raoul
2010-01-01
AIMS To report a case of severe delayed methotrexate elimination attributable to consumption of a cola beverage. METHODS To investigate unexplained low urinary pH in a lymphoma patient treated with high-dose methotrexate. RESULTS Unexpected urinary acidity, despite administration of large amounts of sodium bicarbonate, could be attributed to repeated consumption of a cola beverage. It resulted in a delayed elimination of methotrexate and acute renal failure. Discontinuation of cola drinks, increase in calcium folinate rescue and in sodium bicarbonate allowed satisfactory elimination of methotrexate on day 12 after infusion and recovery from renal impairment without other severe toxicity. No other cause of delay in methotrexate elimination could be identified. CONCLUSIONS Cola beverages have a low pH due to their phosphoric acid content that is excreted by renal route. We recommend patients receiving high dose methotrexate abstain from any cola drink within 24 h before and during methotrexate administration and until complete elimination of the drug. PMID:21545633
Erculj, Nina; Kotnik, Barbara Faganel; Debeljak, Marusa; Jazbec, Janez; Dolzan, Vita
2014-01-01
Background We evaluated the influence of folate pathway polymorphisms on high-dose methotrexate (HD-MTX) related toxicity in paediatric patients with T-cell non-Hodgkin lymphoma (NHL). Patients and methods In total, 30 NHL patients were genotyped for selected folate pathway polymorphisms. Results Carriers of at least one MTHFR 677T allele had significantly higher MTX area under the time-concentration curve levels at third MTX cycle (P = 0.003). These patients were also at higher odds of leucopoenia (P = 0.006) or thrombocytopenia (P = 0.041) and had higher number of different HD-MTX-related toxicity (P = 0.035) compared to patients with wild-type genotype. Conclusions Our results suggest an important role of MTHFR 677C>T polymorphism in the development of HD-MTX-related toxicity in children with NHL. PMID:25177243
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinoto, Makoto, E-mail: shinoto@saga-himat.jp; Ion Beam Therapy Center, SAGA HIMAT Foundation, Tosu; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka
Purpose: To determine, in the setting of locally advanced pancreatic cancer, the maximum tolerated dose of carbon ion radiation therapy (C-ion RT) and gemcitabine dose delivered concurrently and to estimate local effect and survival. Methods and Materials: Eligibility included pathologic confirmation of pancreatic invasive ductal carcinomas and radiographically unresectable disease without metastasis. Concurrent gemcitabine was administered on days 1, 8, and 15, and the dose levels were escalated from 400 to 1000 mg/m{sup 2} under the starting dose level (43.2 GyE) of C-ion RT. The dose levels of C-ion RT were escalated from 43.2 to 55.2 GyE at 12 fractions undermore » the fixed recommended gemcitabine dose determined. Results: Seventy-six patients were enrolled. Among the 72 treated patients, dose-limiting toxicity was observed in 3 patients: grade 3 infection in 1 patient and grade 4 neutropenia in 2 patients. Only 1 patient experienced a late grade 3 gastric ulcer and bleeding 10 months after C-ion RT. The recommended dose of gemcitabine with C-ion RT was found to be 1000 mg/m{sup 2}. The dose of C-ion RT with the full dose of gemcitabine (1000 mg/m{sup 2}) was safely increased to 55.2 GyE. The freedom from local progression rate was 83% at 2 years using the Response Evaluation Criteria in Solid Tumors. The 2-year overall survival rates in all patients and in the high-dose group with stage III (≥45.6 GyE) were 35% and 48%, respectively. Conclusions: Carbon ion RT with concurrent full-dose gemcitabine was well tolerated and effective in patients with unresectable locally advanced pancreatic cancer.« less
Oral High-Dose Multivitamins and Minerals or Post Myocardial Infarction Patients in TACT
Lamas, Gervasio A.; Boineau, Robin; Goertz, Christine; Mark, Daniel B.; Rosenberg, Yves; Stylianou, Mario; Rozema, Theodore; Nahin, Richard L.; Lindblad, Lauren; Lewis, Eldrin F.; Drisko, Jeanne; Lee, Kerry L.
2014-01-01
Background Oral multivitamins and minerals are often used in conjunction with ethylenediamine tetra acetic acid infusions to treat atherosclerotic disease. Whether high-dose multivitamins are effective as secondary prevention of atherosclerotic disease, however, has not been established. Objective The vitamin component of the Trial to Assess Chelation Therapy assessed whether oral multivitamins reduced cardiovascular events, and were safe. Design The Trial to Assess Chelation Therapy was designed as a double-blind placebo-controlled 2×2 factorial multicenter randomized trial. Setting 134 US and Canadian academic and clinical sites participated. Patients 1708 patients, age ≥50 years, ≥6 weeks post myocardial infarction, with creatinine level ≤ 176.8 µmol/L (2.0 mg/dL). (ClinicalTrials.gov: NCT00044213). Intervention Patients were randomly assigned to an oral 28-component high-dose multivitamin and multimineral mixture or placebo. Measurements Study results were analyzed per randomized group. The primary endpoint was time to total mortality, recurrent myocardial infarction, stroke, coronary revascularization, or hospitalization for angina. Limited secondary endpoints and subgroup analyses were also pre-specified. Results The median age was 65 years, 18% female. The qualifying myocardial infarction had occurred 4.6 (1.6, 9.2) years prior to enrollment. The median duration of follow-up was 55 months (IQR 26, 60) overall. The median number of months during which patients took their vitamins was 31 (13, 59) in the active treatment group, and 35 (13, 60) in the placebo group (p=0.65). There were 645 (76%) vitamin patients and 646 (76%) placebo patients who completed at least 1 year of oral therapy (p=0.98); and 400 (46.9%) vitamin patients and 426 (49.8%) placebo patients who completed at least 3 years of oral therapy (p=0.23). There were 783 (46%) of patients who discontinued their vitamin regimen (390 (46%) in placebo, 394 (46%) in active; p=0.67), and 17% of patients withdrew from the study. The primary endpoint occurred in 230 (27%) patients in the active vitamin group and 253 (30%) in the placebo group (hazard ratio 0.89, 95% CI 0.75–1.07, p=0.21). There was no evidence suggesting harm from vitamin therapy in any category of adverse events Limitations The study had considerable non-compliance and drop-out. Thus, the ability to draw firm conclusions (particularly regarding safety) is limited. Conclusions High-dose oral multivitamins and multiminerals did not produce a statistically significant reduction in cardiovascular events in post-myocardial infarction patients on standard medications, but this conclusion has to be tempered by the non-compliance rate. Primary Funding Source National Institutes of Health. PMID:24490264
Tardy, Claudine; Goffinet, Marine; Boubekeur, Nadia; Cholez, Guy; Ackermann, Rose; Sy, Gavin; Keyserling, Constance; Lalwani, Narendra; Paolini, John F; Dasseux, Jean-Louis; Barbaras, Ronald; Baron, Rudi
2015-01-01
CER-001 is a novel engineered HDL-mimetic comprised of recombinant human apoA-I and charged phospholipids that was designed to mimic the beneficial properties of nascent pre-ß HDL. In this study, we have evaluated the dose-dependent regulation of ABCA1 expression in vitro and in vivo in the presence of CER-001 and native HDL (HDL3). CER-001 induced cholesterol efflux from J774 macrophages in a dose-dependent manner similar to natural HDL. A strong down-regulation of the ATP-binding cassette A1 (ABCA1) transporter mRNA (- 50%) as well as the ABCA1 membrane protein expression (- 50%) was observed at higher doses of CER-001 and HDL3 compared to non-lipidated apoA-I. In vivo, in an apoE-/- mouse "flow cessation model," in which the left carotid artery was ligatured to induce local inflammation, the inhibition of atherosclerotic plaque burden progression in response to a dose-range of every-other-day CER-001 or HDL in the presence of a high-fat diet for two weeks was assessed. We observed a U-shaped dose-response curve: inhibition of the plaque total cholesterol content increased with increasing doses of CER-001 or HDL3 up to a maximum inhibition (- 51%) at 5 mg/kg; however, as the dose was increased above this threshold, a progressively less pronounced inhibition of progression was observed, reaching a complete absence of inhibition of progression at doses of 20 mg/kg and over. ABCA1 protein expression in the same atherosclerotic plaque was decreased by-45% and-68% at 50 mg/kg for CER-001 and HDL respectively. Conversely, a-12% and 0% decrease in ABCA1 protein expression was observed at the 5 mg/kg dose for CER-001 and HDL respectively. These data demonstrate that high doses of HDL and CER-001 are less effective at slowing progression of atherosclerotic plaque in apoE-/- mice compared to lower doses, following a U-shaped dose-response curve. A potential mechanism for this phenomenon is supported by the observation that high doses of HDL and CER-001 induce a rapid and strong down-regulation of ABCA1 both in vitro and in vivo. In conclusion, maximally efficient HDL- or CER-001-mediated cholesterol removal from atherosclerotic plaque is achieved by maximizing macrophage-mediated efflux from the plaque while minimizing dose-dependent down-regulation of ABCA1 expression. These observations may help define the optimal dose of HDL mimetics for testing in clinical trials of atherosclerotic burden regression.
Mairs, William DA
2016-06-01
The International Commission on Radiological Protection (ICRP) has recommended a 20 mSv year(-1) dose limit for the lens of the eye, which has been adopted in the European Union Basic Safety Standards. Interventional radiologists (IRs) and interventional cardiologists (ICs) are likely to be affected by this. The effects of radiation in the lens are somewhat uncertain, and the ICRP explicitly recommend optimization. Occupational dose constraints are part of the optimization process and define a level of dose which ought to be achievable in a well-managed practice. This commentary calls on the professional bodies to review a need for national constraints to guide local decisions. Consideration is given to developing such constraints using maximum expected doses in high-workload facilities with good radiation protection practices and application of a factor allowing for attenuation by lead glasses (LG). Doses are based on a Public Health England survey of eye dose in the UK. Maximum expected doses for ICs are approximately 21 mSv year(-1), neglecting LG. However, the extent of IR exposure is not yet fully known, and further evidence is required before conclusions are drawn. A Health and Safety Laboratory review of LG established a conservative dose reduction factor of 3 for models available in 2012. Application of this factor provides a dose constraint of 7 mSv year(-1) to the eye for ICs. To achieve this constraint, those employers with the most exposed ICs will have to provide and ensure the correct use of a ceiling-suspended eye shield and LG.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galloway, Thomas J.; University of Florida Proton Therapy Institute, Jacksonville, FL; Indelicato, Daniel J., E-mail: dindelicato@floridaproton.org
Purpose: Second tumors are an uncommon complication of multimodality treatment of childhood cancer. The present analysis attempted to correlate the dose received as a component of primary treatment and the site of the eventual development of a second tumor. Methods and Materials: We retrospectively identified 16 patients who had received radiotherapy to sites in the craniospinal axis and subsequently developed a second tumor. We compared the historical fields and port films of the primary treatment with the modern imaging of the second tumor locations. We classified the location of the second tumors as follows: in the boost field; marginal tomore » the boost field, but in a whole-brain field; in a whole-brain field; marginal to the whole brain/primary treatment field; and distant to the field. We divided the dose received into 3 broad categories: high dose (>45 Gy), moderate dose (20-36 Gy), and low dose (<20 Gy). Results: The most common location of the second tumor was in the whole brain field (57%) and in the moderate-dose range (81%). Conclusions: Our data contradict previous publications that suggested that most second tumors develop in tissues that receive a low radiation dose. Almost all the second tumors in our series occurred in tissue within a target volume in the cranium that had received a moderate dose (20-36 Gy). These findings suggest that a major decrease in the brain volume that receives a moderate radiation dose is the only way to substantially decrease the second tumor rate after central nervous system radiotherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apicello, L; Riegel, A; Jamshidi, A
2015-06-15
Purpose: A sufficient amount of ionizing radiation can cause failure to components of pacemakers. Studies have shown that permanent damage can occur after a dose of 10 Gy and minor damage to functionality occurs at doses as low as 2 Gy. Optically stimulated thermoluminescent dosimeters (OSLDs) can be used as in vivo dosimeters to predict dose to be deposited throughout the treatment. The purpose of this work is to determine the effectiveness of using OSLDs for in vivo dosimetry of pacemaker dose. Methods: As part of a clinical in vivo dosimetry experience, OSLDs were placed at the site of themore » pacemaker by the therapist for one fraction of the radiation treatment. OSLD measurements were extrapolated to the total dose to be received by the pacemaker during treatment. A total of 79 measurements were collected from November 2011 to December 2013 on six linacs. Sixty-six (66) patients treated in various anatomical sites had the dose of their pacemakers monitored. Results: Of the 79 measurements recorded, 76 measurements (96 %) were below 2 Gy. The mean and standard deviation were 50.12 ± 76.41 cGy. Of the 3 measurements that exceeded 2 Gy, 2 measurements matched the dose predicted in the treatment plan and 1 was repeated after an unexpectedly high Result. The repeated measurement yielded a total dose less than 2 Gy. Conclusion: This analysis suggests OSLDs may be used for in vivo monitoring of pacemaker dose. Further research should be performed to assess the effect of increased backscatter from the pacemaker device.« less
Wang, Wei-Hong; Huang, Jia-Qing; Zheng, Ge-Fan; Xia, Harry Hua-Xiang; Wong, Wai-Man; Lam, Shiu-Kum; Wong, Benjamin Chun-Yu
2005-01-01
AIM: To systematically evaluate the efficacy of H2-receptor antagonists (H2RAs) and proton pump inhibitors in healing erosive esophagitis (EE). METHODS: A meta-analysis was performed. A literature search was conducted in PubMed, Medline, Embase, and Cochrane databases to include randomized controlled head-to-head comparative trials evaluating the efficacy of H2RAs or proton pump inhibitors in healing EE. Relative risk (RR) and 95% confidence interval (CI) were calculated under a random-effects model. RESULTS: RRs of cumulative healing rates for each comparison at 8 wk were: high dose vs standard dose H2RAs, 1.17 (95%CI, 1.02-1.33); standard dose proton pump inhibitors vs standard dose H2RAs, 1.59 (95%CI, 1.44-1.75); standard dose other proton pump inhibitors vs standard dose omeprazole, 1.06 (95%CI, 0.98-1.06). Proton pump inhibitors produced consistently greater healing rates than H2RAs of all doses across all grades of esophagitis, including patients refractory to H2RAs. Healing rates achieved with standard dose omeprazole were similar to those with other proton pump inhibitors in all grades of esophagitis. CONCLUSION: H2RAs are less effective for treating patients with erosive esophagitis, especially in those with severe forms of esophagitis. Standard dose proton pump inhibitors are significantly more effective than H2RAs in healing esophagitis of all grades. Proton pump inhibitors given at the recommended dose are equally effective for healing esophagitis. PMID:15996033
SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knewtson, T; Pokhrel, S; University of Tennessee Health Science Center, Memphis, TN
2016-06-15
Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. Themore » fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.« less
Zeidan, Amer M; Smith, B Douglas; Carraway, Hetty E; Gojo, Ivana; DeZern, Amy; Gore, Steven D
2017-01-01
Limited therapies exist for patients with refractory and relapsed (RR) higher-risk myelodysplastic syndromes (HR-MDS) and acute myeloid leukaemia with trilineage dysplasia (AML-TD). High dose (HD) lenalidomide (50 mg) has activity as frontline therapy in elderly AML but there is limited data in the RR setting. This phase II trial included patients with RR HR-MDS or AML-TD at 2 doses of lenalidomide (15 or 50 mg) on days 1-28 of 42-day cycles. The primary endpoint was response rate using the 2006 International Working Group criteria. Overall survival (OS) was estimated by Kaplan-Meier methods. Of 27 patients enrolled, 59% had HR-MDS and 31% AML-TD. No patient had isolated del5q; 41% had poor-risk karyotype. Of 9 patients treated at 15 mg, 56% completed ≥2 cycles with no responses. Of 18 patients treated at 50 mg, 39% completed ≥2 cycles and 11% responded but all experienced grade 3/4 neutropenic fever/infection. The 60-day mortality rate was 30%. Median OS was 114 days with 19% surviving ≥1 year. The study was terminated due to lack of robust clinical activity. In conclusion, lenalidomide at 15 mg is ineffective in RR myeloid malignancies. Continous high dosing schedules are poorly tolerated and minimally active. Further evaluation should be considered in upfront intensive chemotherapy-ineligible patients. © 2016 John Wiley & Sons Ltd.
Nederlof, Rianne; Xie, Chaoqin; Eerbeek, Otto; Koeman, Anneke; Milstein, Dan MJ; Hollmann, Markus W; Mik, Egbert G; Warley, Alice; Southworth, Richard; Akar, Fadi G.; Zuurbier, Coert J
2013-01-01
Rationale We have shown that partial dissociation of HKII from mitochondria in the intact heart using low dose (200 nM) TAT-HKII prevents the cardioprotective effects of ischemic preconditioning (IPC) whereas high-dose (10 μM) TAT-HKII administration results in rapid myocardial dysfunction, mitochondrial depolarization and disintegration. In this issue of Circulation Research, Pasdois et al argue that the deleterious effects of TAT-HKII administration on cardiac function are likely due to vasoconstriction and ensuing ischemia. Objective To investigate whether altered vascular function and ensuing ischemia recapitulate the deleterious effects of TAT-HKII in intact myocardium. Methods and Results Using a variety of complementary techniques, including mitochondrial membrane potential (ΔΨm) imaging, high-resolution optical action potential (AP) mapping, analysis of lactate production, NADH epifluorescence, lactate dehydrogenase (LDH) release, and electron microscopy, we provide direct evidence that refutes the notion that acute myocardial dysfunction by high-dose TAT-HKII peptide administration is a consequence of impaired vascular function. Moreover, we demonstrate that low-dose TAT-HKII treatment, which abrogates the protective effects of IPC, is not associated with ischemia or ischemic-injury. Conclusions Our findings challenge the notion that the effects of TAT-HKII are attributable to impaired vascular function and ensuing ischemia; thereby, lending further credence to the role of mitochondria bound HKII as a critical regulator of cardiac function, ischemia-reperfusion (IR) injury, and cardioprotection by IPC. PMID:23329797
Lu, Ting; Sheng, Hongguang; Wu, Johnna; Cheng, Yuan; Zhu, Jianming; Chen, Yan
2012-06-01
For thousands of years, cinnamon has been used as a traditional treatment in China. However, there are no studies to date that investigate whether cinnamon supplements are able to aid in the treatment of type 2 diabetes in Chinese subjects. We hypothesized cinnamon should be effective in improving blood glucose control in Chinese patients with type 2 diabetes. To address this hypothesis, we performed a randomized, double-blinded clinical study to analyze the effect of cinnamon extract on glycosylated hemoglobin A(1c) and fasting blood glucose levels in Chinese patients with type 2 diabetes. A total of 66 patients with type 2 diabetes were recruited and randomly divided into 3 groups: placebo and low-dose and high-dose supplementation with cinnamon extract at 120 and 360 mg/d, respectively. Patients in all 3 groups took gliclazide during the entire 3 months of the study. Both hemoglobin A(1c) and fasting blood glucose levels were significantly reduced in patients in the low- and high-dose groups, whereas they were not changed in the placebo group. The blood triglyceride levels were also significantly reduced in the low-dose group. The blood levels of total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, and liver transaminase remained unchanged in the 3 groups. In conclusion, our study indicates that cinnamon supplementation is able to significantly improve blood glucose control in Chinese patients with type 2 diabetes. Copyright © 2012 Elsevier Inc. All rights reserved.
Hauber, A Brett; Han, Steven; Yang, Jui-Chen; Gantz, Ira; Tunceli, Kaan; Gonzalez, Juan Marcos; Brodovicz, Kimberly; Alexander, Charles M; Davies, Michael; Iglay, Kristy; Zhang, Qiaoyi; Radican, Larry
2013-01-01
Purpose To quantify willingness-to-pay (WTP) for reducing pill burden and dosing frequency among patients with type 2 diabetes mellitus (T2DM), and to examine the effect of dosing frequency and pill burden on likely medication adherence. Patients and methods Participants were US adults with T2DM on oral antihyperglycemic therapy. Each patient completed an online discrete-choice experiment (DCE) with eight choice questions, each including a pair of hypothetical medication profiles. Each profile was defined by reduction in average glucose (AG), daily dosing, chance of mild-to-moderate stomach problems, frequency of hypoglycemia, weight change, incremental risk of congestive heart failure (CHF), and cost. Patients were asked to rate their likely adherence to the profiles presented in each question. Choice questions were based on a predetermined experimental design. Choice data were analyzed using random-parameters logit. Likely treatment adherence was analyzed using a Heckman two-stage model. Results Of the 1,114 patients who completed the survey, 90 had lower dosing burden (<5 pills/day taken once/day or as needed) for all medications, and 1,024 had higher dosing burden (≥5 pills/day or more than once/day). Reduction in AG was valued most highly by patients. Hypoglycemia, chance of mild-to-moderate stomach problems, weight change, incremental risk of CHF, and daily dosing were less valued. Patients with higher current dosing burden had lower WTP for more convenient dosing schedules than patients with lower current dosing burden. Changes in dosing and cost impacted likely adherence. The magnitude of the impact of dosing on likely adherence was higher for patients with lower current dosing burden than for patients with higher current dosing burden. Conclusion Patients with T2DM were willing to pay for improvements in efficacy, side effects, and dosing. Patients’ WTP for more convenient dosing depended on current dosing burden, as did the effect of these attributes on likely adherence. PMID:24086104
SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W; Kenneth, R; Higgins, S
Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry formore » CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.« less
SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalavagunta, C; Lasio, G; Yi, B
2015-06-15
Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquiredmore » for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.« less
Weitz, Jeffrey I; Bauersachs, Rupert; Beyer-Westendorf, Jan; Bounameaux, Henri; Brighton, Timothy A; Cohen, Alexander T; Davidson, Bruce L; Holberg, Gerlind; Kakkar, Ajay; Lensing, Anthonie W A; Prins, Martin; Haskell, Lloyd; van Bellen, Bonno; Verhamme, Peter; Wells, Philip S; Prandoni, Paolo
2015-08-31
Patients with unprovoked venous thromboembolism (VTE) are at high risk for recurrence. Although rivaroxaban is effective for extended VTE treatment at a dose of 20 mg once daily, use of the 10 mg dose may further improve its benefit-to-risk ratio. Low-dose aspirin also reduces rates of recurrent VTE, but has not been compared with anticoagulant therapy. The EINSTEIN CHOICE study is a multicentre, randomised, double-blind, active-controlled, event-driven study comparing the efficacy and safety of two once daily doses of rivaroxaban (20 and 10 mg) with aspirin (100 mg daily) for the prevention of recurrent VTE in patients who completed 6-12 months of anticoagulant therapy for their index acute VTE event. All treatments will be given for 12 months. The primary efficacy objective is to determine whether both doses of rivaroxaban are superior to aspirin for the prevention of symptomatic recurrent VTE, while the principal safety outcome is the incidence of major bleeding. The trial is anticipated to enrol 2,850 patients from 230 sites in 31 countries over a period of 27 months. In conclusion, the EINSTEIN CHOICE study will provide new insights into the optimal antithrombotic strategy for extended VTE treatment by comparing two doses of rivaroxaban with aspirin (clinicaltrials.gov NCT02064439).
2010-01-01
Background Methadone is a synthetic opiate mu receptor agonist that is widely used to substitute for illicit opiates in the management of opiate dependence. It helps prevent opiate users from injecting and sharing needles which are vehicles for the spread of HIV and other blood borne viruses. This study has the objective of determining the utility of daily methadone dose to predict retention rates and re-injecting behaviour among opiate dependents. Methods Subjects comprised opiate dependent individuals who met study criteria. They took methadone based on the Malaysian guidelines and were monitored according to the study protocols. At six months, data was collected for analyses. The sensitivity and specificity daily methadone doses to predict retention rates and re-injecting behaviour were evaluated. Results Sixty-four patients volunteered to participate but only 35 (54.69%) remained active and 29 (45.31%) were inactive at 6 months of treatment. Higher doses were significantly correlated with retention rate (p < 0.0001) and re-injecting behaviour (p < 0.001). Of those retained, 80.0% were on 80 mg or more methadone per day doses with 20.0% on receiving 40 mg -79 mg. Conclusions We concluded that a daily dose of at least 40 mg was required to retain patients in treatment and to prevent re-injecting behaviour. A dose of at least 80 mg per day was associated with best results. PMID:21167035
CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and Operator
Neeman, Ziv; Dromi, Sergio A.; Sarin, Shawn; Wood, Bradford J.
2008-01-01
PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surface dosimetry was performed on adult and pediatric phantoms. The shielding was composed of tungsten antimony in the form of a lightweight polymer sheet. Doses to the patient were measured with and without shielding for thoracic and abdominal procedures. Doses to the operator were recorded with and without phantom, gantry, and table shielding in place. Double-layer lead-free gloves were used by the operator during the procedures. RESULTS Tungsten antimony shielding adjacent to the scan plane resulted in a maximum dose reduction of 92.3% to the patient. Maximum 85.6%, 93.3%, and 85.1% dose reductions were observed for the operator’s torso, gonads, and hands, respectively. The use of double-layer lead-free gloves resulted in a maximum radiation dose reduction of 97%. CONCLUSIONS Methods to reduce exposure during CT fluoroscopy are effective and should be searched for. Significant reduction in radiation doses to the patient and operator can be accomplished with tungsten antimony shielding. PMID:17185699
Bruno, Antonio; Pandolfo, Gianluca; Crucitti, Manuela; Cacciola, Massimo; Santoro, Vincenza; Spina, Edoardo; Zoccali, Rocco A; Muscatello, Maria R A
2017-01-01
Objectives: The nutraceutical approach to the management of metabolic syndrome (MetS) might be a promising strategy in the prevention of cardio-metabolic risk. Low-dose bergamot-derived polyphenolic fraction (BPF) has been proven effective in patients with MetS, as demonstrated by a concomitant improvement in lipemic and glycemic profiles. The present study was aimed to further explore, in a sample of subjects receiving second generation antipsychotics (SGAs), the effects on body weight and metabolic parameters of a low dose of BPF (500 mg/day) administered for 60 days. Methods: Twenty-eight outpatients treated with SGAs assumed BPF at single daily dose of 500 mg/day for 60 days. Body weight, BMI, fasting levels of glucose, total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol and triglycerides were determined; moreover, Brief Psychiatric Rating Scale (BPRS) was administered. Results: Low-dose BPF administration did not change clinical and metabolic parameters, as well as clinical symptoms in the study sample. At the end of the trial, among completers ( n = 24) only nine patients (37.5%) reached an LDL reduction >0 but <50%. Conclusions: Our results demonstrate that patients treated with SGAs may need higher BPF doses for obtaining the positive effects on body weight and metabolic parameters previously found in the general population at lower doses.
Bruno, Antonio; Pandolfo, Gianluca; Crucitti, Manuela; Cacciola, Massimo; Santoro, Vincenza; Spina, Edoardo; Zoccali, Rocco A.; Muscatello, Maria R. A.
2017-01-01
Objectives: The nutraceutical approach to the management of metabolic syndrome (MetS) might be a promising strategy in the prevention of cardio-metabolic risk. Low-dose bergamot-derived polyphenolic fraction (BPF) has been proven effective in patients with MetS, as demonstrated by a concomitant improvement in lipemic and glycemic profiles. The present study was aimed to further explore, in a sample of subjects receiving second generation antipsychotics (SGAs), the effects on body weight and metabolic parameters of a low dose of BPF (500 mg/day) administered for 60 days. Methods: Twenty-eight outpatients treated with SGAs assumed BPF at single daily dose of 500 mg/day for 60 days. Body weight, BMI, fasting levels of glucose, total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol and triglycerides were determined; moreover, Brief Psychiatric Rating Scale (BPRS) was administered. Results: Low-dose BPF administration did not change clinical and metabolic parameters, as well as clinical symptoms in the study sample. At the end of the trial, among completers (n = 24) only nine patients (37.5%) reached an LDL reduction >0 but <50%. Conclusions: Our results demonstrate that patients treated with SGAs may need higher BPF doses for obtaining the positive effects on body weight and metabolic parameters previously found in the general population at lower doses. PMID:28443024
Dynamic intensity-weighted region of interest imaging for conebeam CT
Pearson, Erik; Pan, Xiaochuan; Pelizzari, Charles
2017-01-01
BACKGROUND Patient dose from image guidance in radiotherapy is small compared to the treatment dose. However, the imaging beam is untargeted and deposits dose equally in tumor and healthy tissues. It is desirable to minimize imaging dose while maintaining efficacy. OBJECTIVE Image guidance typically does not require full image quality throughout the patient. Dynamic filtration of the kV beam allows local control of CT image noise for high quality around the target volume and lower quality elsewhere, with substantial dose sparing and reduced scatter fluence on the detector. METHODS The dynamic Intensity-Weighted Region of Interest (dIWROI) technique spatially varies beam intensity during acquisition with copper filter collimation. Fluence is reduced by 95% under the filters with the aperture conformed dynamically to the ROI during cone-beam CT scanning. Preprocessing to account for physical effects of the collimator before reconstruction is described. RESULTS Reconstructions show image quality comparable to a standard scan in the ROI, with higher noise and streak artifacts in the outer region but still adequate quality for patient localization. Monte Carlo modeling shows dose reduction by 10–15% in the ROI due to reduced scatter, and up to 75% outside. CONCLUSIONS The presented technique offers a method to reduce imaging dose by accepting increased image noise outside the ROI, while maintaining full image quality inside the ROI. PMID:27257875
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dréan, Gaël; Acosta, Oscar, E-mail: Oscar.Acosta@univ-rennes1.fr; Simon, Antoine
2016-06-15
Purpose: Recent studies revealed a trend toward voxelwise population analysis in order to understand the local dose/toxicity relationships in prostate cancer radiotherapy. Such approaches require, however, an accurate interindividual mapping of the anatomies and 3D dose distributions toward a common coordinate system. This step is challenging due to the high interindividual variability. In this paper, the authors propose a method designed for interindividual nonrigid registration of the rectum and dose mapping for population analysis. Methods: The method is based on the computation of a normalized structural description of the rectum using a Laplacian-based model. This description takes advantage of themore » tubular structure of the rectum and its centerline to be embedded in a nonrigid registration-based scheme. The performances of the method were evaluated on 30 individuals treated for prostate cancer in a leave-one-out cross validation. Results: Performance was measured using classical metrics (Dice score and Hausdorff distance), along with new metrics devised to better assess dose mapping in relation with structural deformation (dose-organ overlap). Considering these scores, the proposed method outperforms intensity-based and distance maps-based registration methods. Conclusions: The proposed method allows for accurately mapping interindividual 3D dose distributions toward a single anatomical template, opening the way for further voxelwise statistical analysis.« less
Effect of beam channel plugging on the outcome of gamma knife radiosurgery for trigeminal neuralgia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massager, Nicolas; Nissim, Ouzi; Murata, Noriko
2006-07-15
Purpose: We studied the influence of using plugs for brainstem protection during gamma knife radiosurgery (GKR) of trigeminal neuralgia (TN), with special emphasis on irradiation doses delivered to the trigeminal nerve, pain outcomes, and incidence of trigeminal dysfunction. Methods and Materials: A GKR procedure for TN using an anterior cisternal target and a maximum dose of 90 Gy was performed in 109 patients. For 49 patients, customized beam channel blocking (plugs) were used to reduce the dose delivered to the brainstem. We measured the mean and integrated radiation doses delivered to the trigeminal nerve and the clinical course of patientsmore » treated with and without plugs. Results: We found that blocking increases the length of trigeminal nerve exposed to high-dose radiation, resulting in a significantly higher mean dose to the trigeminal nerve. Significantly more of the patients with blocking achieved excellent pain outcomes (84% vs. 62%), but with higher incidences of moderate and bothersome trigeminal nerve dysfunction (37% mild/10% bothersome with plugs vs. 30% mild/2% bothersome without). Conclusions: The use of plugs to protect the brainstem during GKR treatment for TN increases the dose of irradiation delivered to the intracisternal trigeminal nerve root and is associated with an important increase in the incidence of trigeminal nerve dysfunction. Therefore, beam channel blocking should be avoided for 90 Gy-GKR of TN.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peeters, Stephanie; Hoogeman, Mischa S.; Heemsbergen, Wilma D.
2006-09-01
Purpose: To analyze whether inclusion of predisposing clinical features in the Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model improves the estimation of late gastrointestinal toxicity. Methods and Materials: This study includes 468 prostate cancer patients participating in a randomized trial comparing 68 with 78 Gy. We fitted the probability of developing late toxicity within 3 years (rectal bleeding, high stool frequency, and fecal incontinence) with the original, and a modified LKB model, in which a clinical feature (e.g., history of abdominal surgery) was taken into account by fitting subset specific TD50s. The ratio of these TD50s is the dose-modifyingmore » factor for that clinical feature. Dose distributions of anorectal (bleeding and frequency) and anal wall (fecal incontinence) were used. Results: The modified LKB model gave significantly better fits than the original LKB model. Patients with a history of abdominal surgery had a lower tolerance to radiation than did patients without previous surgery, with a dose-modifying factor of 1.1 for bleeding and of 2.5 for fecal incontinence. The dose-response curve for bleeding was approximately two times steeper than that for frequency and three times steeper than that for fecal incontinence. Conclusions: Inclusion of predisposing clinical features significantly improved the estimation of the NTCP. For patients with a history of abdominal surgery, more severe dose constraints should therefore be used during treatment plan optimization.« less
Ozkurt, Huseyin; Tokgoz, Safiye; Karabay, Esra; Ucan, Berna; Akdogan, Melek Pala; Basak, Muzaffer
2014-01-01
Aim To evaluate the diagnostic quality of a new multiple detector-row computed tomography angiography (MDCT-A) protocol using low dose radiation and low volume contrast medium techniques for evaluation of non-cardiac chest pain. Methods Forty-five consecutive patients with clinically suspected noncardiac chest pain and requiring contrast-enhanced chest computed tomography (CT) were examined. The patients were assigned to the protocol, with 80 kilovolt (peak) (kV[p]) and 150 effective milliampere-second (eff mA-s). In our study group, 40 mL of low osmolar contrast material was administered at 3.0 mL/s. Results In the study group, four patients with pulmonary embolism, four with pleural effusion, two with ascending aortic aneurysm and eight patients with pneumonic consolidation were detected. The mean attenuation of the pulmonary truncus and ascendant aortic locations was considered 264±44 and 249±51 HU, respectively. The mean effective radiation dose was 0.83 mSv for MDCT-A. Conclusions Pulmonary artery and the aorta scanning simultaneously was significantly reduced radiation exposure with the mentioned dose saving technique. Additionally, injection of low volume (40 cc) contrast material may reduce the risk of contrast induced nephropathy, therefore, facilitate the diagnostic approach. This technique can be applied to all cases and particularly patients at high risk of contrast induced nephropathy due to its similar diagnostic quality with a low dose and high levels of arteriovenous enhancement simultaneously. PMID:25392818
Dose Response of Endotoxin on Hepatocyte and Muscle Mitochondrial Respiration In Vitro
Brandt, Sebastian; Porta, Francesca; Jakob, Stephan M.; Takala, Jukka; Djafarzadeh, Siamak
2015-01-01
Introduction. Results on mitochondrial dysfunction in sepsis are controversial. We aimed to assess effects of LPS at wide dose and time ranges on hepatocytes and isolated skeletal muscle mitochondria. Methods. Human hepatocellular carcinoma cells (HepG2) were exposed to placebo or LPS (0.1, 1, and 10 μg/mL) for 4, 8, 16, and 24 hours and primary human hepatocytes to 1 μg/mL LPS or placebo (4, 8, and 16 hours). Mitochondria from porcine skeletal muscle samples were exposed to increasing doses of LPS (0.1–100 μg/mg) for 2 and 4 hours. Respiration rates of intact and permeabilized cells and isolated mitochondria were measured by high-resolution respirometry. Results. In HepG2 cells, LPS reduced mitochondrial membrane potential and cellular ATP content but did not modify basal respiration. Stimulated complex II respiration was reduced time-dependently using 1 μg/mL LPS. In primary human hepatocytes, stimulated mitochondrial complex II respiration was reduced time-dependently using 1 μg/mL LPS. In isolated porcine skeletal muscle mitochondria, stimulated respiration decreased at high doses (50 and 100 μg/mL LPS). Conclusion. LPS reduced cellular ATP content of HepG2 cells, most likely as a result of the induced decrease in membrane potential. LPS decreased cellular and isolated mitochondrial respiration in a time-dependent, dose-dependent and complex-dependent manner. PMID:25649304
Aasa, Jenny; Törnqvist, Margareta; Abramsson-Zetterberg, Lilianne
2017-11-01
In this study 3-monochloropropane-1,2-diol (3-MCPD), a compound that appears as contaminant in refined cooking oils, has been studied with regard to genotoxicity in vivo (mice) with simultaneous measurement of internal dose using state-of-the-art methodologies. Genotoxicity (chromosomal aberrations) was measured by flow cytometry with dual lasers as the frequency of micronuclei in erythrocytes in peripheral blood from BalbC mice intraperitoneally exposed to 3-MCPD (0, 50, 75, 100, 125 mg/kg). The internal doses of 3-MCPD in the mice were calculated from N-(2,3-dihydroxypropyl)-valine adducts to hemoglobin (Hb), quantified at very low levels by high-resolution mass spectrometry. Convincing evidence for absence of genotoxic potency in correlation to measured internal doses in the mice was demonstrated, despite relatively high administered doses of 3-MCPD. The results are discussed in relation to another food contaminant that is formed as ester in parallel to 3-MCPD esters in oil processing, i.e. glycidol, which has been studied previously by us in a similar experimental setup. Glycidol has been shown to be genotoxic, and in addition to have ca. 1000 times higher rate of adduct formation compared to that observed for 3-MCPD. The conclusion is that at simultaneous exposure to 3-MCPD and glycidol the concern about genotoxicity would be glycidol. Copyright © 2017 Elsevier Ltd. All rights reserved.
Olatunji, Lawrence Aderemi; Oyeyipo, Ibukun Peter; Usman, Taofeek Oluwamayowa
2013-01-01
Oral contraceptive (OC) use and increased fructose feeding have been associated with altered cardiometabolic effects. The effect of increased dietary fructose during OC use on cardiometabolic parameters is unknown. We investigated the effects of a high-fructose diet on body weight gain, fasting blood glucose, glucose tolerance, plasma lipid and hemorheological parameters in female rats treated with a combination of OC steroids (norgestrel/ethinyl estradiol; NEE). Rats were given (p.o.) vehicle, high-dose NEE (10.0 μg norgestrel/1.0 μg ethinyl estradiol) or low-dose NEE (1.0 μg norgestrel/0.1 μg ethinyl estradiol) with or without high dietary fructose daily for 6 weeks. Results demonstrated that high-dose NEE but not low-dose NEE treatment led to significant increases in hematocrit, blood viscosity, and decreases in body weight gain, glucose tolerance, and plasma HDL-cholesterol level. Both NEE treatments resulted in significant increases in plasma viscosity and triglyceride. Increased dietary fructose without NEE treatment produced significant increases in fasting blood glucose, hematocrit, blood and plasma viscosities, while increased dietary fructose significantly potentiated the effects on blood and plasma viscosities observed during NEE treatment. Conversely, the effects of NEE treatment on body weight gain, glucose tolerance, plasma triglyceride and HDL-cholesterol were significantly attenuated. In conclusion, the results indicate that increase in dietary fructose may worsen abnormal blood rheology. The results also demonstrate that increased dietary fructose may not impact negatively on glucose and lipid metabolisms during OC use. The findings imply that fructose-enriched diet might be an important consideration during OC use regarding blood rheological properties.
Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images
Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang
2015-01-01
Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [18F]FDG PET image by using a low-dose brain [18F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [18F]FDG PET image by low-dose brain [18F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [18F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [18F]FDG PET image and substantially enhanced image quality of low-dose brain [18F]FDG PET image. Conclusions: In this paper, the authors propose a framework to generate standard-dose brain [18F]FDG PET image using low-dose brain [18F]FDG PET and MRI images. Both the visual and quantitative results indicate that the standard-dose brain [18F]FDG PET can be well-predicted using MRI and low-dose brain [18F]FDG PET. PMID:26328979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, Jiayin; Gao, Yaozong; Shi, Feng
Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. Asmore » yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET image and substantially enhanced image quality of low-dose brain [{sup 18}F]FDG PET image. Conclusions: In this paper, the authors propose a framework to generate standard-dose brain [{sup 18}F]FDG PET image using low-dose brain [{sup 18}F]FDG PET and MRI images. Both the visual and quantitative results indicate that the standard-dose brain [{sup 18}F]FDG PET can be well-predicted using MRI and low-dose brain [{sup 18}F]FDG PET.« less
Scott, B R; Lyzlov, A F; Osovets, S V
1998-05-01
During a Phase-I effort, studies were planned to evaluate deterministic (nonstochastic) effects of chronic exposure of nuclear workers at the Mayak atomic complex in the former Soviet Union to relatively high levels (> 0.25 Gy) of ionizing radiation. The Mayak complex has been used, since the late 1940's, to produce plutonium for nuclear weapons. Workers at Site A of the complex were involved in plutonium breeding using nuclear reactors, and some were exposed to relatively large doses of gamma rays plus relatively small neutron doses. The Weibull normalized-dose model, which has been set up to evaluate the risk of specific deterministic effects of combined, continuous exposure of humans to alpha, beta, and gamma radiations, is here adapted for chronic exposure to gamma rays and neutrons during repeated 6-h work shifts--as occurred for some nuclear workers at Site A. Using the adapted model, key conclusions were reached that will facilitate a Phase-II study of deterministic effects among Mayak workers. These conclusions include the following: (1) neutron doses may be more important for Mayak workers than for Japanese A-bomb victims in Hiroshima and can be accounted for using an adjusted dose (which accounts for neutron relative biological effectiveness); (2) to account for dose-rate effects, normalized dose X (a dimensionless fraction of an LD50 or ED50) can be evaluated in terms of an adjusted dose; (3) nonlinear dose-response curves for the risk of death via the hematopoietic mode can be converted to linear dose-response curves (for low levels of risk) using a newly proposed dimensionless dose, D = X(V), in units of Oklad (where D is pronounced "deh"), and V is the shape parameter in the Weibull model; (4) for X < or = Xo, where Xo is the threshold normalized dose, D = 0; (5) unlike absorbed dose, the dose D can be averaged over different Mayak workers in order to calculate the average risk of death via the hematopoietic mode for the population exposed at Site A; and (6) the expected cases of death via the hematopoietic syndrome mode for Mayak workers chronically exposed during work shifts at Site A to gamma rays and neutrons can be predicted using ln(2)B M[D]; where B (pronounced "beh") is the number of workers at risk (criticality accident victims excluded); and M[D] is the average (mean) value of D (averaged over the worker population at risk, for Site A, for the time period considered). These results can be used to facilitate a Phase II study of deterministic radiation effects among Mayak workers chronically exposed to gamma rays and neutrons.
High energy x-ray phase contrast CT using glancing-angle grating interferometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarapata, A., E-mail: adrian.sarapata@tum.de; Stayman, J. W.; Siewerdsen, J. H.
Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code themore » authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, B; Miften, M
2014-06-15
Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed a method using these projections to determine the trajectory and dose of highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, where the trajectory mimicked a lung tumor with high amplitude (2.4 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each projection. A Gaussian probability density function for tumor position was calculated which best fit the observed trajectory ofmore » the BB in the imager geometry. Two methods to improve the accuracy of tumor track reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation, and second, using the Monte Carlo method to sample the estimated Gaussian tumor position distribution. 15 clinically-drawn abdominal/lung CTV volumes were used to evaluate the accuracy of the proposed methods by comparing the known and calculated BB trajectories. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square (RMS) trajectory errors were lower than 5% of marker amplitude. Use of respiratory phase information decreased RMS errors by 30%, and decreased the fraction of large errors (>3 mm) by half. Mean dose to the clinical volumes was calculated with an average error of 0.1% and average absolute error of 0.3%. Dosimetric parameters D90/D95 were determined within 0.5% of maximum dose. Monte-Carlo sampling increased RMS trajectory and dosimetric errors slightly, but prevented over-estimation of dose in trajectories with high noise. Conclusions: Tumor trajectory and dose-of-the-day were accurately calculated using CBCT projections. This technique provides a widely-available method to evaluate highly-mobile tumors, and could facilitate better strategies to mitigate or compensate for motion during SBRT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Best, R; Harrell, A; Geesey, C
2014-06-15
Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parametersmore » of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, C; Palma, B; Qu, B
2014-06-01
Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned usingmore » a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from RaySearch laboratories; B Hardemark and E Hynning are employees of RaySearch.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deeg, H.J.; Storb, R.; Weiden, P.L.
1981-11-01
Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs diedmore » from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors.« less
TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bostani, M; Cagnon, C; Sepahdari, A
Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv andmore » above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement in patient management. Dr. McNitt-Gray’s disclosures: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less