Sample records for concordance correlation coefficient

  1. Modeling Concordance Correlation Coefficient for Longitudinal Study Data

    ERIC Educational Resources Information Center

    Ma, Yan; Tang, Wan; Yu, Qin; Tu, X. M.

    2010-01-01

    Measures of agreement are used in a wide range of behavioral, biomedical, psychosocial, and health-care related research to assess reliability of diagnostic test, psychometric properties of instrument, fidelity of psychosocial intervention, and accuracy of proxy outcome. The concordance correlation coefficient (CCC) is a popular measure of…

  2. Real external predictivity of QSAR models: how to evaluate it? Comparison of different validation criteria and proposal of using the concordance correlation coefficient.

    PubMed

    Chirico, Nicola; Gramatica, Paola

    2011-09-26

    The main utility of QSAR models is their ability to predict activities/properties for new chemicals, and this external prediction ability is evaluated by means of various validation criteria. As a measure for such evaluation the OECD guidelines have proposed the predictive squared correlation coefficient Q(2)(F1) (Shi et al.). However, other validation criteria have been proposed by other authors: the Golbraikh-Tropsha method, r(2)(m) (Roy), Q(2)(F2) (Schüürmann et al.), Q(2)(F3) (Consonni et al.). In QSAR studies these measures are usually in accordance, though this is not always the case, thus doubts can arise when contradictory results are obtained. It is likely that none of the aforementioned criteria is the best in every situation, so a comparative study using simulated data sets is proposed here, using threshold values suggested by the proponents or those widely used in QSAR modeling. In addition, a different and simple external validation measure, the concordance correlation coefficient (CCC), is proposed and compared with other criteria. Huge data sets were used to study the general behavior of validation measures, and the concordance correlation coefficient was shown to be the most restrictive. On using simulated data sets of a more realistic size, it was found that CCC was broadly in agreement, about 96% of the time, with other validation measures in accepting models as predictive, and in almost all the examples it was the most precautionary. The proposed concordance correlation coefficient also works well on real data sets, where it seems to be more stable, and helps in making decisions when the validation measures are in conflict. Since it is conceptually simple, and given its stability and restrictiveness, we propose the concordance correlation coefficient as a complementary, or alternative, more prudent measure of a QSAR model to be externally predictive.

  3. [Dental arch form reverting by four-point method].

    PubMed

    Pan, Xiao-Gang; Qian, Yu-Fen; Weng, Si-En; Feng, Qi-Ping; Yu, Quan

    2008-04-01

    To explore a simple method of reverting individual dental arch form template for wire bending. Individual dental arch form was reverted by four-point method. By defining central point of bracket on bilateral lower second premolar and first molar, certain individual dental arch form could be generated. The arch form generating procedure was then be developed to computer software for printing arch form. Four-point method arch form was evaluated by comparing with direct model measurement on linear and angular parameters. The accuracy and reproducibility were assessed by paired t test and concordance correlation coefficient with Medcalc 9.3 software package. The arch form by four-point method was of good accuracy and reproducibility (linear concordance correlation coefficient was 0.9909 and angular concordance correlation coefficient was 0.8419). The dental arch form reverted by four-point method could reproduce the individual dental arch form.

  4. A short note on jackknifing the concordance correlation coefficient.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2014-02-10

    Lin's concordance correlation coefficient (CCC) is a very popular scaled index of agreement used in applied statistics. To obtain a confidence interval (CI) for the estimate of CCC, jackknifing was proposed and shown to perform well in simulation as well as in applications. However, a theoretical proof of the validity of the jackknife CI for the CCC has not been presented yet. In this note, we establish a sufficient condition for using the jackknife method to construct the CI for the CCC. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL-Adults Study.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-17

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5)) -18 ) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin's concordance correlation coefficient, linear regression, Bland-Altman's agreement analysis, concordance correlation coefficient ( ρc ) and the coefficient of determination ( R ²) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R ² = 0.384, p < 0.001. A paired-sample t -test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = -6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin's concordance correlation coefficient was poor ( ρc = 0.014, 95% CI = -0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels.

  6. A Bayesian Framework for Estimating the Concordance Correlation Coefficient Using Skew-elliptical Distributions.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2018-04-05

    The concordance correlation coefficient (CCC) is a widely used scaled index in the study of agreement. In this article, we propose estimating the CCC by a unified Bayesian framework that can (1) accommodate symmetric or asymmetric and light- or heavy-tailed data; (2) select model from several candidates; and (3) address other issues frequently encountered in practice such as confounding covariates and missing data. The performance of the proposal was studied and demonstrated using simulated as well as real-life biomarker data from a clinical study of an insomnia drug. The implementation of the proposal is accessible through a package in the Comprehensive R Archive Network.

  7. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL—Adults Study

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-01

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5))−18) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin’s concordance correlation coefficient, linear regression, Bland–Altman’s agreement analysis, concordance correlation coefficient (ρc) and the coefficient of determination (R2) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R2 = 0.384, p < 0.001. A paired-sample t-test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = −6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin’s concordance correlation coefficient was poor (ρc = 0.014, 95% CI = −0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels. PMID:28106719

  8. Transcultural adaptation and psychometric properties of Spanish version of Pregnancy Physical Activity Questionnaire: the PregnActive project.

    PubMed

    Oviedo-Caro, Miguel Ángel; Bueno-Antequera, Javier; Munguía-Izquierdo, Diego

    2018-03-19

    To transculturally adapt the Spanish version of Pregnancy Physical Activity Questionnaire (PPAQ) analyzing its psychometric properties. The PPAQ was transculturally adapted into Spanish. Test-retest reliability was evaluated in a subsample of 109 pregnant women. The validity was evaluated in a sample of 208 pregnant women who answered the questionnaire and wore the multi-sensor monitor for 7 valid days. The reliability (intraclass correlation coefficient), concordance (concordance correlation coefficient), correlation (Pearson correlation coefficient), agreement (Bland-Altman plots) and relative activity levels (Jonckheere-Terpstra test) between both administrations and methods were examined. Intraclass correlation coefficients between both administrations were good for all categories except transportation. A low but significant correlation was found for total activity (light and above) whereas no correlation was found for other intensities between both methods. Relative activity levels analysis showed a significant linear trend for increased total activity between both methods. Spanish version of PPAQ is a brief and easily interpretable questionnaire with good reliability and ability to rank individuals, and poor validity compared with multi-sensor monitor. The use of PPAQ provides information of pregnancy-specific activities in order to establish physical activity levels of pregnant women and adapt health promotion interventions. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. [Concordance of glomerular filtration rate with creatinine clearance in 24-hour urine and Schwartz and Schwartz updated].

    PubMed

    Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne

    Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  10. A robust bayesian estimate of the concordance correlation coefficient.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2015-01-01

    A need for assessment of agreement arises in many situations including statistical biomarker qualification or assay or method validation. Concordance correlation coefficient (CCC) is one of the most popular scaled indices reported in evaluation of agreement. Robust methods for CCC estimation currently present an important statistical challenge. Here, we propose a novel Bayesian method of robust estimation of CCC based on multivariate Student's t-distribution and compare it with its alternatives. Furthermore, we extend the method to practically relevant settings, enabling incorporation of confounding covariates and replications. The superiority of the new approach is demonstrated using simulation as well as real datasets from biomarker application in electroencephalography (EEG). This biomarker is relevant in neuroscience for development of treatments for insomnia.

  11. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    PubMed

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

    PubMed

    Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline

    2018-01-01

    To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.

  13. Validation of Pooled Whole-Genome Re-Sequencing in Arabidopsis lyrata.

    PubMed

    Fracassetti, Marco; Griffin, Philippa C; Willi, Yvonne

    2015-01-01

    Sequencing pooled DNA of multiple individuals from a population instead of sequencing individuals separately has become popular due to its cost-effectiveness and simple wet-lab protocol, although some criticism of this approach remains. Here we validated a protocol for pooled whole-genome re-sequencing (Pool-seq) of Arabidopsis lyrata libraries prepared with low amounts of DNA (1.6 ng per individual). The validation was based on comparing single nucleotide polymorphism (SNP) frequencies obtained by pooling with those obtained by individual-based Genotyping By Sequencing (GBS). Furthermore, we investigated the effect of sample number, sequencing depth per individual and variant caller on population SNP frequency estimates. For Pool-seq data, we compared frequency estimates from two SNP callers, VarScan and Snape; the former employs a frequentist SNP calling approach while the latter uses a Bayesian approach. Results revealed concordance correlation coefficients well above 0.8, confirming that Pool-seq is a valid method for acquiring population-level SNP frequency data. Higher accuracy was achieved by pooling more samples (25 compared to 14) and working with higher sequencing depth (4.1× per individual compared to 1.4× per individual), which increased the concordance correlation coefficient to 0.955. The Bayesian-based SNP caller produced somewhat higher concordance correlation coefficients, particularly at low sequencing depth. We recommend pooling at least 25 individuals combined with sequencing at a depth of 100× to produce satisfactory frequency estimates for common SNPs (minor allele frequency above 0.05).

  14. Dietary quality varies according to data collection instrument: a comparison between a food frequency questionnaire and 24-hour recall.

    PubMed

    Rodrigues, Paulo Rogério Melo; de Souza, Rita Adriana Gomes; De Cnop, Mara Lima; Monteiro, Luana Silva; Coura, Camila Pinheiro; Brito, Alessandra Page; Pereira, Rosangela Alves

    2016-02-01

    The objective of this study was to assess the agreement between the Brazilian Healthy Eating Index - Revised (BHEI-R), estimated by a food frequency questionnaire (FFQ) and multiple 24-hour recalls (24h-R). The Wilcoxon paired test, partial correlations (PC), intraclass correlation coefficient (ICC), and Bland-Altman method were used. The total BHEI-R scores and its components ("total fruits", "whole fruits", "total vegetables", "integral cereals", "saturated fat", "sodium", and "energy intake derived from solid fat, added sugar, and alcoholic beverages") were statistically different, with the ICC and PC indicating poor concordance and correlation. The mean concordance estimated for the total BHEI-R and its components varied from 68% for "integral cereals" to 147% for "whole fruits". The suitable concordance limits were violated for most of the components of the BHEI-R. Poor concordance was observed between the BHEI-R estimated by the FFQ and by multiple 24h-R, which indicated a strong reliability of the BHEI-R on the instrument used to collect information on food consumption.

  15. Ambulatory stress monitoring with a wearable bluetooth electrocardiographic device.

    PubMed

    Hong, Sungyoup; Yang, Youngmo; Lee, Jangyoung; Yang, Heebum; Park, Kyungnam; Lee, Suyeul; Lee, Inbum; Jang, Yongwon

    2010-01-01

    We tried to monitor stress by using a wearable one channel ECG device that can send ECG signals through Bluetooth wireless communication. Noxious physical and mental arithmetic stress was given three times repeatedly to healthy adults, and cortisol and catecholamines were measured serially from peripheral blood. At the same time, time domain and frequency domain parameters of heart rate variability (HRV) were calculated by taking precordial electrocardiogram. The intensity of correlation between subjective visual analogue scale (VAS) and catecholamine, cortisol, and HRV parameters according to stress was analyzed by using concordance correlation coefficients. The HRV triangular index and LF/HF ratio had high concordance correlation with the degree of stress in the physical stress model. In mental arithmetic stress model, the HRV triangular index and LF/HF ratio had weak concordance correlation with the degree of stress, and it had lower predictability than epinephrine. In both models, cortisol had some correlation with catecholamine, but it had little correlation with HRV parameters. HRV parameters using wearable one channel ECG device can be useful in predicting acute stress and also in many other areas.

  16. Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring.

    PubMed

    Thiele, Robert H; Colquhoun, Douglas A; Patrie, James; Nie, Sarah H; Huffmyer, Julie L

    2011-12-01

    To assess the relation between photoplethysmographically-derived parameters and invasively-determined hemodynamic variables. After induction of anesthesia and placement of a Swan-Ganz CCOmbo catheter, a Nonin OEM III probe was placed on each patient's earlobe. Photoplethysmographic signals were recorded in conjunction with cardiac output. Photoplethysmographic metrics (amplitude of absorbance waveform, maximal slope of absorbance waveform, area under the curve, and width) were calculated offline and compared with invasively determined hemodynamic variables. Subject-specific associations between each dependent and independent variable pair were summarized on a per-subject basis by the nonparametric Spearman rank correlation coefficient. The bias-corrected accelerated bootstrap resampling procedure of Efron and Tibshirani was used to obtain a 95% confidence interval for the median subject-specific correlation coefficient, and Wilcoxon sign-rank tests were conducted to test the null hypothesis that the median of the subject-specific correlation coefficients were equal to 0. University hospital. Eighteen patients undergoing coronary artery bypass graft surgery. Placement of a Swan-Ganz CCOmbo catheter and a Nonin OEM III pulse oximetry probe. There was a positive, statistically significant correlation between stroke volume and width (median correlation coefficient, 0.29; confidence interval, 0.01-0.46; p = 0.034). The concordance between changes in stroke volume and changes in width was 53%. No other correlations achieved statistical significance. This study was unable to reproduce the results of prior studies. Only stroke volume and photoplethysmographic width were correlated in this study; however, the correlation and concordance (based on analysis of a 4-quadrant plot) were too weak to be clinically useful. Future studies in patients undergoing low-to-moderate risk surgery may result in improved correlations and clinical utility. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    PubMed

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  18. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; García-Hermoso, Antonio; Triana-Reina, Hector Reynaldo

    2016-01-01

    The body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied. PMID:27916871

  19. Comparison of 5 Ki-67 antibodies regarding reproducibility and capacity to predict prognosis in breast cancer: does the antibody matter?

    PubMed

    Ács, Balázs; Kulka, Janina; Kovács, Kristóf Attila; Teleki, Ivett; Tőkés, Anna-Mária; Meczker, Ágnes; Győrffy, Balázs; Madaras, Lilla; Krenács, Tibor; Szász, Attila Marcell

    2017-07-01

    Although several antibodies are available for immunohistochemical detection of Ki-67, even the most commonly used MIB-1 has not been validated yet. Our aim was to compare 5 commercially available antibodies for detection of Ki-67 in terms of agreement and their ability in predicting prognosis of breast cancer. Tissue microarrays were constructed from 378 breast cancer patients' representative formalin-fixed, paraffin-embedded tumor blocks. Five antibodies were used to detect Ki-67 expression: MIB-1 using chromogenic detection and immunofluorescent-labeled MIB-1, SP-6, 30-9, poly, and B56. Semiquantitative assessment was performed by 2 pathologists independently on digitized slides. To compare the 5 antibodies, intraclass correlation and concordance correlation coefficient were used. All the antibodies but immunofluorescent-labeled MIB-1 (at 20% and 30% thresholds, P=.993 and P=.342, respectively) and B56 (at 30% threshold, P=.288) separated high- and low-risk patient groups. However, there were a significant difference (P values for all comparisons≤.005) and a moderate concordance (intraclass correlation, 0.645) between their Ki-67 labeling index scores. The highest concordance was found between MIB-1 and poly (concordance correlation coefficient=0.785) antibodies. None of the antibodies except Ki-67 labeling index as detected by poly (P=.031) at 20% threshold and lymph node status (P<.001) were significantly linked to disease-free survival in multivariate analysis. At 30% threshold, this was reduced to lymph node status (P<.001) alone. Our results showed that there are considerable differences between the different Ki-67 antibodies in their capacity to detect proliferating tumor cells and to separate low- and high-risk breast cancer patient groups. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Concordance and Reliability of Photogrammetric Protocols for Measuring the Cervical Lordosis Angle: A Systematic Review of the Literature.

    PubMed

    de Albuquerque, Priscila Maria Nascimento Martins; de Alencar, Geisa Guimarães; de Oliveira, Daniela Araújo; de Siqueira, Gisela Rocha

    2018-01-01

    The aim of this study was to examine and interpret the concordance, accuracy, and reliability of photogrammetric protocols available in the literature for evaluating cervical lordosis in an adult population aged 18 to 59 years. A systematic search of 6 electronic databases (MEDLINE via PubMed, LILACS, CINAHL, Scopus, ScienceDirect, and Web of Science) located studies that assessed the reliability and/or concordance and/or accuracy of photogrammetric protocols for evaluating cervical lordosis, compared with radiography. Articles published through April 2016 were selected. Two independent reviewers used a critical appraisal tool (QUADAS and QAREL) to assess the quality of the selected studies. Two studies were included in the review and had high levels of reliability (intraclass correlation coefficient: 0.974-0.98). Only 1 study assessed the concordance between the methods, which was calculated using Pearson's correlation coefficient. To date, the accuracy of photogrammetry has not been investigated thoroughly. We encountered no study in the literature that investigated the accuracy of photogrammetry in diagnosing hyperlordosis of cervical spine. However, both current studies report high levels of intra- and interrater reliability. To increase the level of evidence of photogrammetry in the evaluation of cervical lordosis, it is necessary to conduct further studies using a larger sample to increase the external validity of the findings. Copyright © 2018. Published by Elsevier Inc.

  1. Examining the Reliability of Interval Level Data Using Root Mean Square Differences and Concordance Correlation Coefficients

    ERIC Educational Resources Information Center

    Barchard, Kimberly A.

    2012-01-01

    This article introduces new statistics for evaluating score consistency. Psychologists usually use correlations to measure the degree of linear relationship between 2 sets of scores, ignoring differences in means and standard deviations. In medicine, biology, chemistry, and physics, a more stringent criterion is often used: the extent to which…

  2. Comparison of Oncotype DX® Recurrence Score® with other risk assessment tools including the Nottingham Prognostic Index in the identification of patients with low-risk invasive breast cancer.

    PubMed

    Cotter, Maura Bríd; Dakin, Alex; Maguire, Aoife; Walshe, Janice M; Kennedy, M John; Dunne, Barbara; Riain, Ciarán Ó; Quinn, Cecily M

    2017-09-01

    Oncotype DX® is a gene expression assay that quantifies the risk of distant recurrence in patients with hormone receptor positive early breast cancer, publicly funded in Ireland since 2011. The aim of this study was to correlate Oncotype DX® risk groupings with traditional histopathological parameters and the results of other risk assessment tools including Recurrence Score-Pathology-Clinical (RSPC), Adjuvant Risk Index (Adj RI), Nottingham Prognostic Index (NPI) and the Adjuvant! Online 10-year score (AO). Patients were retrospectively identified from the histopathology databases of two Irish hospitals and patient and tumour characteristics collated. Associations between categorical variables were evaluated with Pearson's chi-square test. Correlations were calculated using Spearman's correlation coefficient and concordance using Lin's concordance correlation coefficient. Statistical analysis was performed using SPSS software, version 22.0.In our 300 patient cohort, Oncotype DX® classified 59.7% (n = 179) as low, 30% (n = 90) as intermediate, and 10.3% (n = 31) as high risk. Overall concordance between the RS and RSPC, Adj RI, NPI, and AO was 67.3% (n = 202), 56.3% (n = 169), 59% (n = 177), and 36.3% (n = 109), respectively. All risk assessment tools classified the majority of patients as low risk apart from the AO 10-year score, with RSPC classifying the highest number of patients as low risk. This study demonstrates that there is good correlation between the RS and scores obtained using alternative risk tools. Concordance with NPI is strong, particularly in the low-risk group. NPI, calculated from traditional clinicopathological characteristics, is a reliable alternative to Oncotype DX® in the identification of low-risk patients who may avoid adjuvant chemotherapy.

  3. The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Tordecilla-Sanders, Alejandra; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline; González-Jiménez, Emilio

    2017-09-21

    The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson's correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t -test, Lin's concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin's concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (-5.6 (95%CI -6.4 to -4.8); p < 0.001). In the women, these differences were (-3.6 (95%CI -4.7 to -2.5); p < 0.001). Overall, the bias of the BAI-BF% was -4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups.

  4. The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity

    PubMed Central

    González-Ruíz, Katherine; Schmidt-RioValle, Jacqueline

    2017-01-01

    The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson’s correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t-test, Lin’s concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin’s concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (−5.6 (95% CI −6.4 to −4.8); p < 0.001). In the women, these differences were (−3.6 (95% CI −4.7 to −2.5); p < 0.001). Overall, the bias of the BAI-BF% was −4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups. PMID:28934175

  5. Measurement of the area of venous ulcers using two software programs 1

    PubMed Central

    Eberhardt, Thaís Dresch; de Lima, Suzinara Beatriz Soares; Lopes, Luis Felipe Dias; Borges, Eline de Lima; Weiller, Teresinha Heck; da Fonseca, Graziele Gorete Portella

    2016-01-01

    ABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm². PMID:27992028

  6. Open source posturography.

    PubMed

    Rey-Martinez, Jorge; Pérez-Fernández, Nicolás

    2016-12-01

    The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent of the used force platform technical specifications. Develop and validate a posturography software and share its source code in open source terms. Prospective non-randomized validation study: 20 consecutive adults underwent two balance assessment tests, six condition posturography was performed using a clinical approved software and force platform and the same conditions were measured using the new developed open source software using a low cost force platform. Intra-class correlation index of the sway area obtained from the center of pressure variations in both devices for the six conditions was the main variable used for validation. Excellent concordance between RombergLab and clinical approved force platform was obtained (intra-class correlation coefficient =0.94). A Bland and Altman graphic concordance plot was also obtained. The source code used to develop RombergLab was published in open source terms.

  7. A comparative analysis of modeled and monitored ambient hazardous air pollutants in Texas: a novel approach using concordance correlation.

    PubMed

    Lupo, Philip J; Symanski, Elaine

    2009-11-01

    Often, in studies evaluating the health effects of hazardous air pollutants (HAPs), researchers rely on ambient air levels to estimate exposure. Two potential data sources are modeled estimates from the U.S. Environmental Protection Agency (EPA) Assessment System for Population Exposure Nationwide (ASPEN) and ambient air pollutant measurements from monitoring networks. The goal was to conduct comparisons of modeled and monitored estimates of HAP levels in the state of Texas using traditional approaches and a previously unexploited method, concordance correlation analysis, to better inform decisions regarding agreement. Census tract-level ASPEN estimates and monitoring data for all HAPs throughout Texas, available from the EPA Air Quality System, were obtained for 1990, 1996, and 1999. Monitoring sites were mapped to census tracts using U.S. Census data. Exclusions were applied to restrict the monitored data to measurements collected using a common sampling strategy with minimal missing values over time. Comparisons were made for 28 HAPs in 38 census tracts located primarily in urban areas throughout Texas. For each pollutant and by year of assessment, modeled and monitored air pollutant annual levels were compared using standard methods (i.e., ratios of model-to-monitor annual levels). Concordance correlation analysis was also used, which assesses linearity and agreement while providing a formal method of statistical inference. Forty-eight percent of the median model-to-monitor values fell between 0.5 and 2, whereas only 17% of concordance correlation coefficients were significant and greater than 0.5. On the basis of concordance correlation analysis, the findings indicate there is poorer agreement when compared with the previously applied ad hoc methods to assess comparability between modeled and monitored levels of ambient HAPs.

  8. The accuracy of parent-reported height and weight for 6-12 year old U.S. children.

    PubMed

    Wright, Davene R; Glanz, Karen; Colburn, Trina; Robson, Shannon M; Saelens, Brian E

    2018-02-12

    Previous studies have examined correlations between BMI calculated using parent-reported and directly-measured child height and weight. The objective of this study was to validate correction factors for parent-reported child measurements. Concordance between parent-reported and investigator measured child height, weight, and BMI (kg/m 2 ) among participants in the Neighborhood Impact on Kids Study (n = 616) was examined using the Lin coefficient, where a value of ±1.0 indicates perfect concordance and a value of zero denotes non-concordance. A correction model for parent-reported height, weight, and BMI based on commonly collected demographic information was developed using 75% of the sample. This model was used to estimate corrected measures for the remaining 25% of the sample and measured concordance between correct parent-reported and investigator-measured values. Accuracy of corrected values in classifying children as overweight/obese was assessed by sensitivity and specificity. Concordance between parent-reported and measured height, weight and BMI was low (0.007, - 0.039, and - 0.005 respectively). Concordance in the corrected test samples improved to 0.752 for height, 0.616 for weight, and 0.227 for BMI. Sensitivity of corrected parent-reported measures for predicting overweight and obesity among children in the test sample decreased from 42.8 to 25.6% while specificity improved from 79.5 to 88.6%. Correction factors improved concordance for height and weight but did not improve the sensitivity of parent-reported measures for measuring child overweight and obesity. Future research should be conducted using larger and more nationally-representative samples that allow researchers to fully explore demographic variance in correction coefficients.

  9. Validity and reliability of the Diagnostic Adaptive Behaviour Scale.

    PubMed

    Tassé, M J; Schalock, R L; Balboni, G; Spreat, S; Navas, P

    2016-01-01

    The Diagnostic Adaptive Behaviour Scale (DABS) is a new standardised adaptive behaviour measure that provides information for evaluating limitations in adaptive behaviour for the purpose of determining a diagnosis of intellectual disability. This article presents validity evidence and reliability data for the DABS. Validity evidence was based on comparing DABS scores with scores obtained on the Vineland Adaptive Behaviour Scale, second edition. The stability of the test scores was measured using a test and retest, and inter-rater reliability was assessed by computing the inter-respondent concordance. The DABS convergent validity coefficients ranged from 0.70 to 0.84, while the test-retest reliability coefficients ranged from 0.78 to 0.95, and the inter-rater concordance as measured by intraclass correlation coefficients ranged from 0.61 to 0.87. All obtained validity and reliability indicators were strong and comparable with the validity and reliability coefficients of the most commonly used adaptive behaviour instruments. These results and the advantages of the DABS for clinician and researcher use are discussed. © 2015 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  10. A comparison of confidence interval methods for the concordance correlation coefficient and intraclass correlation coefficient with small number of raters.

    PubMed

    Feng, Dai; Svetnik, Vladimir; Coimbra, Alexandre; Baumgartner, Richard

    2014-01-01

    The intraclass correlation coefficient (ICC) with fixed raters or, equivalently, the concordance correlation coefficient (CCC) for continuous outcomes is a widely accepted aggregate index of agreement in settings with small number of raters. Quantifying the precision of the CCC by constructing its confidence interval (CI) is important in early drug development applications, in particular in qualification of biomarker platforms. In recent years, there have been several new methods proposed for construction of CIs for the CCC, but their comprehensive comparison has not been attempted. The methods consisted of the delta method and jackknifing with and without Fisher's Z-transformation, respectively, and Bayesian methods with vague priors. In this study, we carried out a simulation study, with data simulated from multivariate normal as well as heavier tailed distribution (t-distribution with 5 degrees of freedom), to compare the state-of-the-art methods for assigning CI to the CCC. When the data are normally distributed, the jackknifing with Fisher's Z-transformation (JZ) tended to provide superior coverage and the difference between it and the closest competitor, the Bayesian method with the Jeffreys prior was in general minimal. For the nonnormal data, the jackknife methods, especially the JZ method, provided the coverage probabilities closest to the nominal in contrast to the others which yielded overly liberal coverage. Approaches based upon the delta method and Bayesian method with conjugate prior generally provided slightly narrower intervals and larger lower bounds than others, though this was offset by their poor coverage. Finally, we illustrated the utility of the CIs for the CCC in an example of a wake after sleep onset (WASO) biomarker, which is frequently used in clinical sleep studies of drugs for treatment of insomnia.

  11. [Concordance between central venous and arterial blood gases in post-surgical myocardial revascularization patients in stable condition].

    PubMed

    Santos-Martínez, Luis Efren; Guevara-Carrasco, Marlene; Naranjo-Ricoy, Guillermo; Baranda-Tovar, Francisco Martín; Moreno-Ruíz, Luis Antonio; Herrera-Velázquez, Marco Antonio; Magaña-Serrano, José Antonio; Valencia-Sánchez, Jesús Salvador; Calderón-Abbo, Moisés Cutiel

    2014-01-01

    The concordance between the parameters of arterial and central venous blood gases has not been defined yet. We studied the concordance between both parameters in post-surgical myocardial revascularization patients in stable condition. Consecutive subjects were studied in a cross-sectional design. The position of the central venous catheter was performed and simultaneously we obtained arterial and central venous blood samples prior to discharge from the intensive care unit. Data are expressed according to Bland-Altman statistical method and the intraclass correlation coefficient. Statistical result was accepted at P<.05. Two hundred and six samples were studied of 103 post-surgical patients, pH and lactate had a mean difference (limits of agreement) 0.029±0.048 (-0018, 0.077) and -0.12±0.22 (-0.57, 0.33) respectively. The magnitude of the intraclass correlation coefficient was 0.904 and 0.943 respectively. The values related to oxygen pressure were 27.86±6.08 (15.9, 39.8) and oxygen saturation 33.02±6.13 (21, 45), with magnitude of 0.258 and 0.418 respectively. The best matching parameters between arterial and central venous blood samples were pH and lactate. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  12. Concordance analysis of paired cancer antigen (CA) 15-3 and 27.29 testing.

    PubMed

    Lin, David C; Genzen, Jonathan R

    2018-01-01

    Cancer antigens (CA) 15-3 and 27.29 are used in the clinical management of many breast cancer patients. Given that immunoassays for CA 15-3 and CA 27.29 target epitopes on the same glycoprotein-Mucin 1 (MUC1)-the present analysis was conducted to evaluate the potential concordance of tumor marker results when both tests were ordered by providers on the same specimens. A retrospective limited dataset of paired CA 15-3 (Roche Diagnostics) and CA 27.29 (Siemens Diagnostics) test results was obtained from a national clinical reference laboratory. Concordance according to reference interval (RI) status and percent (%) change between consecutive test results was analyzed. 37,652 paired results from 12,470 distinct patients were obtained. The correlation between CA 15-3 and CA 27.29 results was high (correlation coefficient: Pearson, 0.967), although across the dataset a significant difference between CA 15-3 and CA 27.29 results was observed (P < 0.05). RI concordance between CA 15-3 and CA 27.29 results was observed in 93.7% of pairs (35,280 of 37,652). Correlation was also observed in the % change of CA 15-3 and CA 27.29 results between consecutive specimens for individual patients. Using doubling or halving thresholds (i.e., 100% increase or 50% decrease), concordance in % change was observed between CA 15-3 and CA 27.29 in approximately 90% of cases. Individual patient results trended similarly across both markers over time. While generally concordant, CA 15-3 and CA 27.29 results should not be used interchangeably. The present report provides no evidence for added value in performing both tests routinely for individual patients.

  13. Diffusion-Weighted PROPELLER MRI for Quantitative Assessment of Liver Tumor Necrotic Fraction and Viable Tumor Volume in VX2 Rabbits

    PubMed Central

    Deng, Jie; Virmani, Sumeet; Young, Joseph; Harris, Kathleen; Yang, Guang-Yu; Rademaker, Alfred; Woloschak, Gayle; Omary, Reed A.; Larson, Andrew C.

    2010-01-01

    Purpose To test the hypothesis that diffusion-weighted (DW)-PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI provides more accurate liver tumor necrotic fraction (NF) and viable tumor volume (VTV) measurements than conventional DW-SE-EPI (spin echo echo-planar imaging) methods. Materials and Methods Our institutional Animal Care and Use Committee approved all experiments. In six rabbits implanted with 10 VX2 liver tumors, DW-PROPELLER and DW-SE-EPI scans were performed at contiguous axial slice positions covering each tumor volume. Apparent diffusion coefficient maps of each tumor were used to generate spatially resolved tumor viability maps for NF and VTV measurements. We compared NF, whole tumor volume (WTV), and VTV measurements to corresponding reference standard histological measurements based on correlation and concordance coefficients and the Bland–Altman analysis. Results DW-PROPELLER generally improved image quality with less distortion compared to DW-SE-EPI. DW-PROPELLER NF, WTV, and VTV measurements were strongly correlated and satisfactorily concordant with histological measurements. DW-SE-EPI NF measurements were weakly correlated and poorly concordant with histological measurements. Bland–Altman analysis demonstrated that DWPROPELLER WTV and VTV measurements were less biased from histological measurements than the corresponding DW-SE-EPI measurements. Conclusion DW-PROPELLER MRI can provide spatially resolved liver tumor viability maps for accurate NF and VTV measurements, superior to DW-SE-EPI approaches. DWPROPELLER measurements may serve as a noninvasive surrogate for pathology, offering the potential for more accurate assessments of therapy response than conventional anatomic size measurements. PMID:18407540

  14. Assessing clinical reasoning in optometry using the script concordance test.

    PubMed

    Faucher, Caroline; Dufour-Guindon, Marie-Pier; Lapointe, Gabrielle; Gagnon, Robert; Charlin, Bernard

    2016-05-01

    Clinical reasoning is central to any health profession but its development among learners is difficult to assess. Over the last few decades, the script concordance test (SCT) has been developed to solve this dilemma and has been used in many health professions; however, no study has been published on the use of the script concordance test in optometry. The purpose of this study was to develop and validate a script concordance test for the field of optometry. A 101-question script concordance test (27 short clinical scenarios) was developed and administered online to a convenience sample of 23 second-year and 19 fourth-year students of optometry. It was also administered to a reference panel of 12 experienced optometrists to develop the scoring key. An item-total correlation was calculated for each question. Cronbach's alpha coefficient was used to evaluate the script concordance test reliability and a t-test compared the two groups. A final 77-question script concordance test was created by eliminating questions with low item-total correlation. Cronbach's alpha for this optimised 77-question script concordance test was 0.80. A group comparison revealed that the second-year students' scores (n = 23; mean score = 66.4 ± 7.87 per cent) were statistically lower (t = -4.141; p < 0.001) than those of the fourth-year students (n = 19; mean score = 75.5 ± 5.97 per cent). The online script concordance test developed for this study was found to be both reliable and capable of discriminating between second- and fourth-year optometric students. These results demonstrate that the script concordance test may be considered as a new tool in the optometric educators' assessment arsenal. Further studies will be needed to cover additional levels of professional development. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

  15. NovoTTF™-100A System (Tumor Treating Fields) transducer array layout planning for glioblastoma: a NovoTAL™ system user study.

    PubMed

    Chaudhry, Aafia; Benson, Laura; Varshaver, Michael; Farber, Ori; Weinberg, Uri; Kirson, Eilon; Palti, Yoram

    2015-11-11

    Optune™, previously known as the NovoTTF-100A System™, generates Tumor Treating Fields (TTFields), an effective anti-mitotic therapy for glioblastoma. The system delivers intermediate frequency, alternating electric fields to the supratentorial brain. Patient therapy is personalized by configuring transducer array layout placement on the scalp to the tumor site using MRI measurements and the NovoTAL System. Transducer array layout mapping optimizes therapy by maximizing electric field intensity to the tumor site. This study evaluated physician performance in conducting transducer array layout mapping using the NovoTAL System compared with mapping performed by the Novocure in-house clinical team. Fourteen physicians (7 neuro-oncologists, 4 medical oncologists, and 3 neurosurgeons) evaluated five blinded cases of recurrent glioblastoma and performed head size and tumor location measurements using a standard Digital Imaging and Communications in Medicine reader. Concordance with Novocure measurement and intra- and inter-rater reliability were assessed using relevant correlation coefficients. The study criterion for success was a concordance correlation coefficient (CCC) >0.80. CCC for each physician versus Novocure on 20 MRI measurements was 0.96 (standard deviation, SD ± 0.03, range 0.90-1.00), indicating very high agreement between the two groups. Intra- and inter-rater reliability correlation coefficients were similarly high: 0.83 (SD ±0.15, range 0.54-1.00) and 0.80 (SD ±0.18, range 0.48-1.00), respectively. This user study demonstrated an excellent level of concordance between prescribing physicians and Novocure in-house clinical teams in performing transducer array layout planning. Intra-rater reliability was very high, indicating reproducible performance. Physicians prescribing TTFields, when trained on the NovoTAL System, can independently perform transducer array layout mapping required for the initiation and maintenance of patients on TTFields therapy.

  16. Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial.

    PubMed

    Martin, David O; Lemke, Bernd; Birnie, David; Krum, Henry; Lee, Kathy Lai-Fun; Aonuma, Kazutaka; Gasparini, Maurizio; Starling, Randall C; Milasinovic, Goran; Rogers, Tyson; Sambelashvili, Alex; Gorcsan, John; Houmsse, Mahmoud

    2012-11-01

    In patients with sinus rhythm and normal atrioventricular conduction, pacing only the left ventricle with appropriate atrioventricular delays can result in superior left ventricular and right ventricular function compared with standard biventricular (BiV) pacing. To evaluate a novel adaptive cardiac resynchronization therapy ((aCRT) algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular or BiV pacing with dynamic optimization of atrioventricular and interventricular delays. Patients (n = 522) indicated for a CRT-defibrillator were randomized to aCRT vs echo-optimized BiV pacing (Echo) in a 2:1 ratio and followed at 1-, 3-, and 6-month postrandomization. The study met all 3 noninferiority primary objectives: (1) the percentage of aCRT patients who improved in their clinical composite score at 6 months was at least as high in the aCRT arm as in the Echo arm (73.6% vs 72.5%, with a noninferiority margin of 12%; P = .0007); (2) aCRT and echo-optimized settings resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between aortic velocity time integrals at aCRT and Echo settings at randomization (concordance correlation coefficient = 0.93; 95% confidence interval 0.91-0.94) and at 6-month postrandomization (concordance correlation coefficient = 0.90; 95% confidence interval 0.87-0.92); and (3) aCRT did not result in inappropriate device settings. There were no significant differences between the arms with respect to heart failure events or ventricular arrhythmia episodes. Secondary end points showed similar benefit, and right-ventricular pacing was reduced by 44% in the aCRT arm. The aCRT algorithm is safe and at least as effective as BiV pacing with comprehensive echocardiographic optimization. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. [Inter-rater concordance of the "Nursing Activities Score" in intensive care].

    PubMed

    Valls-Matarín, Josefa; Salamero-Amorós, Maria; Roldán-Gil, Carmen; Quintana-Riera, Salvador

    2015-01-01

    To evaluate inter-rater concordance in the valuation of the "Nursing Activities Score". Cross-sectional descriptive study conducted from December 2012 until June 2013 in a general intensive care unit with twelve beds. Three evaluator nurses, simultaneously and independently, through the patient daily charts, scored the nursing workload using Nursing Activities Score scale in all patients admitted over 18 years old. Three hundreds and thirty-nine records were collected. The intra-class correlation coefficient (ICC) between evaluators was 0.92 (0.89-0.94). A perfect concordance was obtained in 39.1% of the items, with 52.2% having a high, and 8.7% having lower concordance, corresponding to two of the items with multiple scoring options. Significant differences between two of the evaluators (P=.049) were found. Although the inter-rater concordance was high, more accurate records are needed to reduce the variability of the items with multiple options and to allow more accuracy in the interpretation and measurement of the data regarding nursing workload. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  18. Concordance Between Patient and Family Reports of Family Functioning in Bipolar I Disorder and Major Depressive Disorder

    PubMed Central

    Weinstock, Lauren M.; Wenze, Susan J.; Munroe, Mary K.; Miller, Ivan W.

    2013-01-01

    Despite the extensive literature on family functioning and mood disorders, less is known about concordance between patient- and family-reported family functioning. To address this question, adults with bipolar I disorder (BD; n = 92), major depressive disorder (MDD; n = 121), and their family members (ns = 135 and 201, respectively) were recruited from hospital sources. All patients and their family members completed the Family Assessment Device (Epstein et al., 1983). Intraclass correlation coefficients revealed that, in contrast to the moderate degree of concordance in the MDD sample, degree of concordance between patient- and family-reported family functioning was significantly weaker in BD. Subsequent analysis revealed that this discordance was driven by the reports of the child and young adolescent family members of the patients with BD. Results highlight the importance of collateral reports in the assessment of family functioning, especially among families of patients with BD, in research and treatment. PMID:23588224

  19. Concordance between patient and family reports of family functioning in bipolar I disorder and major depressive disorder.

    PubMed

    Weinstock, Lauren M; Wenze, Susan J; Munroe, Mary K; Miller, Ivan W

    2013-05-01

    Despite the extensive literature on family functioning and mood disorders, less is known about concordance between patient- and family-reported family functioning. To address this question, adults with bipolar I disorder (BD; n = 92) or major depressive disorder (MDD; n = 121) and their family members (n = 135 and 201, respectively) were recruited from hospital sources. All patients and their family members completed the Family Assessment Device (Epstein, Baldwin, Bishop. J Marital Fam Ther. 9:171-180, 1983). Intraclass correlation coefficients revealed that, in contrast to the moderate degree of concordance in the MDD sample, degree of concordance between patient- and family-reported family functioning was significantly weaker in BD. Subsequent analysis revealed that this discordance was driven by the reports of the child and young adolescent family members of the patients with BD. Results highlight the importance of collateral reports in the assessment of family functioning, especially among families of patients with BD, in research and treatment.

  20. An automated walk-over weighing system as a tool for measuring liveweight change in lactating dairy cows.

    PubMed

    Dickinson, R A; Morton, J M; Beggs, D S; Anderson, G A; Pyman, M F; Mansell, P D; Blackwood, C B

    2013-07-01

    Automated walk-over weighing systems can be used to monitor liveweights of cattle. Minimal literature exists to describe agreement between automated and static scales, and no known studies describe repeatability when used for daily measurements of dairy cows. This study establishes the repeatability of an automated walk-over cattle-weighing system, and agreement with static electronic scales, when used in a commercial dairy herd to weigh lactating cows. Forty-six lactating dairy cows from a seasonal calving, pasture-based dairy herd in southwest Victoria, Australia, were weighed once using a set of static scales and repeatedly using an automated walk-over weighing system at the exit of a rotary dairy. Substantial agreement was observed between the automated and static scales when assessed using Lin's concordance correlation coefficient. Weights measured by the automated walkover scales were within 5% of those measured by the static scales in 96% of weighings. Bland and Altman's 95% limits of agreement were -23.3 to 43.6 kg, a range of 66.9 kg. The 95% repeatability coefficient for automated weighings was 46.3 kg. Removal of a single outlier from the data set increased Lin's concordance coefficient, narrowed Bland and Altman's 95% limits of agreement to a range of 32.5 kg, and reduced the 95% repeatability coefficient to 18.7 kg. Cow misbehavior during walk-over weighing accounted for many of the larger weight discrepancies. The automated walk-over weighing system showed substantial agreement with the static scales when assessed using Lin's concordance correlation coefficient. This contrasted with limited agreement when assessed using Bland and Altman's method, largely due to poor repeatability. This suggests the automated weighing system is inadequate for detecting small liveweight differences in individual cows based on comparisons of single weights. Misbehaviors and other factors can result in the recording of spurious values on walk-over scales. Excluding outlier weights and comparing means of 7 consecutive daily weights may improve agreement sufficiently to allow meaningful assessment of small short-term changes in automated weights in individuals and groups of cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. A Bayesian estimate of the concordance correlation coefficient with skewed data.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2015-01-01

    Concordance correlation coefficient (CCC) is one of the most popular scaled indices used to evaluate agreement. Most commonly, it is used under the assumption that data is normally distributed. This assumption, however, does not apply to skewed data sets. While methods for the estimation of the CCC of skewed data sets have been introduced and studied, the Bayesian approach and its comparison with the previous methods has been lacking. In this study, we propose a Bayesian method for the estimation of the CCC of skewed data sets and compare it with the best method previously investigated. The proposed method has certain advantages. It tends to outperform the best method studied before when the variation of the data is mainly from the random subject effect instead of error. Furthermore, it allows for greater flexibility in application by enabling incorporation of missing data, confounding covariates, and replications, which was not considered previously. The superiority of this new approach is demonstrated using simulation as well as real-life biomarker data sets used in an electroencephalography clinical study. The implementation of the Bayesian method is accessible through the Comprehensive R Archive Network. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Development and validation of two equations based on anthropometry, estimating body fat for the Greek adult population.

    PubMed

    Kanellakis, Spyridon; Skoufas, Efstathios; Khudokonenko, Vladlena; Apostolidou, Eftychia; Gerakiti, Loukia; Andrioti, Maria-Chrysi; Bountouvi, Evangelia; Manios, Yannis

    2017-02-01

    To validate anthropometric equations in the current literature predicting body fat percentage (%BF) in the Greek population, to develop and validate two anthropometric equations estimating %BF, and to compare them with the retrieved equations. Anthropometric data from 642 Greek adults were incorporated. Dual-energy X-ray absorptiometry was used as reference method. The comparison with other equations was made using Bland-Altman analysis, intraclass correlation coefficient, and Lin's concordance correlation coefficient. Nine of the thirty-one retrieved equations had no statistically significant bias. However, all of them had wide limits of agreement (±8.3 to ±16%BF). The equations accrued were: BF% = -0.615-10.948 × sex + 0.321 × waist circumference + 0.502 × hips circumference-0.39 × forearm circumference - 19.768 × height (m) and BF% = -27.787-5.515 × sex-8.419 × height + 0.145 × waist circumference + 0.270 × hips circumference + 7.509 × log of thigh skinfold + 20.090 × log of sum of skinfolds (bicep + tricep + suprailiac + subscapular)-0.445 × forearm circumference. Bland-Altman's reliability analysis showed no significant bias of -0.058 and -0.148%BF and limits of agreement ±8.100 and ±6.056%BF; the intraclass correlation coefficient was 0.955 and 0.976; and Lin's concordance correlation coefficient was 0.914 and 0.951, respectively. Literature equations performed moderately on this study's population. Therefore, two equations were designed and validated. The first one was simple and easily applicable, with measures obtained from a measuring tape, and the second one more complicated yet more accurate and reliable. Both were found to be reliable for the assessment of body composition in the Greek population. © 2017 The Obesity Society.

  3. Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters.

    PubMed

    Berenguer, Roberto; Pastor-Juan, María Del Rosario; Canales-Vázquez, Jesús; Castro-García, Miguel; Villas, María Victoria; Legorburo, Francisco Mansilla; Sabater, Sebastià

    2018-04-24

    Purpose To identify the reproducible and nonredundant radiomics features (RFs) for computed tomography (CT). Materials and Methods Two phantoms were used to test RF reproducibility by using test-retest analysis, by changing the CT acquisition parameters (hereafter, intra-CT analysis), and by comparing five different scanners with the same CT parameters (hereafter, inter-CT analysis). Reproducible RFs were selected by using the concordance correlation coefficient (as a measure of the agreement between variables) and the coefficient of variation (defined as the ratio of the standard deviation to the mean). Redundant features were grouped by using hierarchical cluster analysis. Results A total of 177 RFs including intensity, shape, and texture features were evaluated. The test-retest analysis showed that 91% (161 of 177) of the RFs were reproducible according to concordance correlation coefficient. Reproducibility of intra-CT RFs, based on coefficient of variation, ranged from 89.3% (151 of 177) to 43.1% (76 of 177) where the pitch factor and the reconstruction kernel were modified, respectively. Reproducibility of inter-CT RFs, based on coefficient of variation, also showed large material differences, from 85.3% (151 of 177; wood) to only 15.8% (28 of 177; polyurethane). Ten clusters were identified after the hierarchical cluster analysis and one RF per cluster was chosen as representative. Conclusion Many RFs were redundant and nonreproducible. If all the CT parameters are fixed except field of view, tube voltage, and milliamperage, then the information provided by the analyzed RFs can be summarized in only 10 RFs (each representing a cluster) because of redundancy. © RSNA, 2018 Online supplemental material is available for this article.

  4. I did eat my vegetables. Agreement between parent and child food intake diaries.

    PubMed

    Rangelov, Natalie; Suggs, L Suzanne; Marques-Vidal, Pedro

    2016-12-01

    To assess the level of agreement between children and their parents when reporting a child's food consumption. Cross-sectional study in which children and parents independently completed 7 d food diaries describing the foods and drinks the child consumed at every meal and snack. The association between child and parent reporting was assessed for nineteen food groups using Kendall's tau-b non-parametric correlations, Spearman's rank correlations, kappa coefficients and Lin's concordance measure of agreement. Results were also stratified by gender of the child and his/her grade at school. Households in Ticino, Switzerland, April-June 2014. Two hundred and ninety-nine children aged 6-12 years and one of their parents participated, with 264 providing complete data (35 % completion rate). Results showed a high level of agreement between child and parent reporting. Spearman correlations ranged from 0·55 (sauces) and 0·57 (fatty meat) to 0·80 (fruit), 0·83 (starchy foods) and 0·84 (pastries). All nineteen Spearman correlations were significant at the 0·001 level. Kendall's tau-b correlations ranged from 0·44 (fat meat) to 0·81 (puff pastry). Kappa values showed low to high levels of agreement, ranging from 0·15 (sweets) to 0·77 (puff pastry). Lin's concordance correlation coefficients ranged from 0·39 (whole grains) to 0·86 (puff pastry). When assessing the eating behaviour of children using a 7 d food diary, children's reports might be as reliable as their parents'.

  5. Significant but weak spousal concordance of metabolic syndrome components in Japanese couples.

    PubMed

    Okuda, Tomoko; Miyazaki, Tadayoshi; Sakuragi, Sonoko; Moriguchi, Jiro; Tachibana, Hiroshi; Ohashi, Fumiko; Ikeda, Masayuki

    2014-03-01

    This study was initiated to investigate if spousal concordance in metabolic syndrome (MS) components exist in Japan. In all, 756 couples (mean age: 48.9 and 47.3 years for husbands and wives, respectively) were identified. Each subject was classified as an MS, MS reserves (MSRES) or no risk of MS (NonMS) case after Japanese Ministry of Health, Labour and Welfare (JMHLW) criteria. Criteria of the National Cholesterol Education Program and of the Joint Interim Statement were also applied. With Japanese Ministry of Health, Labor and Welfare (JMHLW) criteria, MS, MSRES and NonMS cases accounted for 11.9, 14.7 and 73.4 % in husbands and 1.6, 3.7 and 94.7 % in wives. Waist circumference (WC), body mass index (BMI), systolic blood pressure (SBP) and hemoglobin A1c (HbA1c) showed significant correlation (p < 0.01). Correlation was also significant (p < 0.05) for mean blood pressure (MBP) and fasting plasma glucose (FPG). When adjusted for age, correlations were significant only for WC, BMI and HbA1c. Furthermore, none of the correlation coefficients were greater than 0.2. Logistic regression analyses did not suggest significant mutual influence in MS status between the couples. Spousal concordance in MS components was detected for WC, BMI, SBP, MBP, FPG and HbA1c, but the correlation was generally weak and modest in Japanese couples.

  6. Differences between genders in colorectal morphology on CT colonography using a quantitative approach: a pilot study.

    PubMed

    Weber, Charles N; Poff, Jason A; Lev-Toaff, Anna S; Levine, Marc S; Zafar, Hanna M

    To explore quantitative differences between genders in morphologic colonic metrics and determine metric reproducibility. Quantitative colonic metrics from 20 male and 20 female CTC datasets were evaluated twice by two readers; all exams were performed after incomplete optical colonoscopy. Intra-/inter-reader reliability was measured with intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Women had overall decreased colonic volume, increased tortuosity and compactness and lower sigmoid apex height on CTC compared to men (p<0.0001,all). Quantitative measurements in colonic metrics were highly reproducible (ICC=0.9989 and 0.9970; CCC=0.9945). Quantitative morphologic differences between genders can be reproducibility measured. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Blood pressure measurement in an ambulatory setting: concordance between physician and patient self-measurement.

    PubMed

    Vinyoles, E; Blancafort, X; López-Quiñones, C; Arqué, M; Brau, A; Cerdán, N; de la Figuera, M; Díaz, F; Pujol, E

    2003-01-01

    The aim of this study was to determine concordance between physician and patient blood pressure (BP) measurements in an ambulatory setting. A diagnostic intervention cross-sectional study using a convenience sample was employed. A total of 106 hypertensive patients were included in the study. Patients who were unable to perform their self-measurement or those with cardiac arrhythmia were excluded. BP was determined nine times in each subject in the medical office in a randomised order: BP was taken three times by the physician using a mercury sphygmomanometer (SPH-Hg), three times by the physician using a validated, automated oscillometer (Omron HEM 705 CP), and three times by the patient himself with the same device. The intraclass correlation coefficient was calculated. In all, 59 women and 47 men aged 65.7 (10) years were analysed. Mean BP measurements for the physician using the mercury sphygmomanometer, the physician using the Omron, and the patient using the same device were: 136 (15.8)/80 (11), 137 (17.9)/80 (10), and 139* (17.6)/80 (10) mmHg, respectively. BP control was 48.1, 48.1, and 36.8*% (*P < 0.05), respectively. Intraclass correlation coefficients for systolic/diastolic pressures were: 0.77/0.65 (physician-sphygmomanometer Hg, physician-Omron; P < 0.001), 0.75/0.64 (physician-sphygmomanometer Hg, patient-Omron, P < 0.001), and 0.83/0.83 (physician-Omron, patient-Omron; P < 0.001). In conclusion, the three types of measurement in the medical office were significantly concordant. Patient office self-measurement showed a tendency to increase systolic BP and worsen BP control.

  8. [Relativity among starch quantity, polysaccharides content and total alkaloid content of Dendrobium loddigesii].

    PubMed

    Zhu, Hua; Teng, Jianbei; Cai, Yi; Liang, Jie; Zhu, Yilin; Wei, Tao

    2011-12-01

    To find out the relativity among starch quantity, polysaccharides content and total alkaloid content of Dendrobium loddigesii. Microscopy-counting process was applied to starch quantity statistics, sulfuric acid-anthrone colorimetry was used to assay polysaccharides content and bromocresol green colorimetry was used to assay alkaloid content. Pearson product moment correlation analysis, Kendall's rank correlation analysis and Spearman's concordance coefficient analysis were applied to study their relativity. Extremely significant positive correlation was found between starch quantity and polysaccharides content, and significant negative correlation between alkaloid content and starch quantity was discovered, as well was between alkaloid content and polysaccharides content.

  9. Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.

    PubMed

    Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E

    2016-11-01

    To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.

  10. Agreement Analysis: What He Said, She Said Versus You Said.

    PubMed

    Vetter, Thomas R; Schober, Patrick

    2018-06-01

    Correlation and agreement are 2 concepts that are widely applied in the medical literature and clinical practice to assess for the presence and strength of an association. However, because correlation and agreement are conceptually distinct, they require the use of different statistics. Agreement is a concept that is closely related to but fundamentally different from and often confused with correlation. The idea of agreement refers to the notion of reproducibility of clinical evaluations or biomedical measurements. The intraclass correlation coefficient is a commonly applied measure of agreement for continuous data. The intraclass correlation coefficient can be validly applied specifically to assess intrarater reliability and interrater reliability. As its name implies, the Lin concordance correlation coefficient is another measure of agreement or concordance. In undertaking a comparison of a new measurement technique with an established one, it is necessary to determine whether they agree sufficiently for the new to replace the old. Bland and Altman demonstrated that using a correlation coefficient is not appropriate for assessing the interchangeability of 2 such measurement methods. They in turn described an alternative approach, the since widely applied graphical Bland-Altman Plot, which is based on a simple estimation of the mean and standard deviation of differences between measurements by the 2 methods. In reading a medical journal article that includes the interpretation of diagnostic tests and application of diagnostic criteria, attention is conventionally focused on aspects like sensitivity, specificity, predictive values, and likelihood ratios. However, if the clinicians who interpret the test cannot agree on its interpretation and resulting typically dichotomous or binary diagnosis, the test results will be of little practical use. Such agreement between observers (interobserver agreement) about a dichotomous or binary variable is often reported as the kappa statistic. Assessing the interrater agreement between observers, in the case of ordinal variables and data, also has important biomedical applicability. Typically, this situation calls for use of the Cohen weighted kappa. Questionnaires, psychometric scales, and diagnostic tests are widespread and increasingly used by not only researchers but also clinicians in their daily practice. It is essential that these questionnaires, scales, and diagnostic tests have a high degree of agreement between observers. It is therefore vital that biomedical researchers and clinicians apply the appropriate statistical measures of agreement to assess the reproducibility and quality of these measurement instruments and decision-making processes.

  11. Clinical and Pathological Staging Validation in the Eighth Edition of the TNM Classification for Lung Cancer: Correlation between Solid Size on Thin-Section Computed Tomography and Invasive Size in Pathological Findings in the New T Classification.

    PubMed

    Aokage, Keiju; Miyoshi, Tomohiro; Ishii, Genichiro; Kusumoto, Masahiro; Nomura, Shogo; Katsumata, Shinya; Sekihara, Keigo; Hishida, Tomoyuki; Tsuboi, Masahiro

    2017-09-01

    The aim of this study was to validate the new eighth edition of the TNM classification and to elucidate whether radiological solid size corresponds to pathological invasive size incorporated in this T factor. We analyzed the data on 1792 patients who underwent complete resection from 2003 to 2011 at the National Cancer Center Hospital East, Japan. We reevaluated preoperative thin-section computed tomography (TSCT) to determine solid size and pathological invasive size using the fourth edition of the WHO classification and reclassified them according to the new TNM classification. The discriminative power of survival curves by the seventh edition was compared with that by the eighth edition by using concordance probability estimates and Akaike's information criteria calculated using a univariable Cox regression model. Pearson's correlation coefficient was calculated to elucidate the correlation between radiological solid size using TSCT and pathological invasive size. The overall survival curves in the eighth edition were well distinct at each clinical and pathological stage. The 5-year survival rates of patients with clinical and pathological stage 0 newly defined were both 100%. The concordance probability estimate and Akaike's information criterion values of the eighth edition were higher than those of the seventh edition in discriminatory power for overall survival. Solid size on TSCT scan and pathological invasive size showed a positive linear relationship, and Pearson's correlation coefficient was calculated as 0.83, which indicated strong correlation. This TNM classification will be feasible regarding patient survival, and radiological solid size correlates significantly with pathological invasive size as a new T factor. Copyright © 2017 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  12. Portable Sleep Monitoring for Diagnosing Sleep Apnea in Hospitalized Patients With Heart Failure.

    PubMed

    Aurora, R Nisha; Patil, Susheel P; Punjabi, Naresh M

    2018-04-21

    Sleep apnea is an underdiagnosed condition in patients with heart failure. Efficient identification of sleep apnea is needed, as treatment may improve heart failure-related outcomes. Currently, use of portable sleep monitoring in hospitalized patients and those at risk for central sleep apnea is discouraged. This study examined whether portable sleep monitoring with respiratory polygraphy can accurately diagnose sleep apnea in patients hospitalized with decompensated heart failure. Hospitalized patients with decompensated heart failure underwent concurrent respiratory polygraphy and polysomnography. Both recordings were scored for obstructive and central disordered breathing events in a blinded fashion, using standard criteria, and the apnea-hypopnea index (AHI) was determined. Pearson's correlation coefficients and Bland-Altman plots were used to examine the concordance among the overall, obstructive, and central AHI values derived by respiratory polygraphy and polysomnography. The sample consisted of 53 patients (47% women) with a mean age of 59.0 years. The correlation coefficient for the overall AHI from the two diagnostic methods was 0.94 (95% CI, 0.89-0.96). The average difference in AHI between the two methods was 3.6 events/h. Analyses of the central and obstructive AHI values showed strong concordance between the two methods, with correlation coefficients of 0.98 (95% CI, 0.96-0.99) and 0.91 (95% CI, 0.84-0.95), respectively. Complete agreement in the classification of sleep apnea severity between the two methods was seen in 89% of the sample. Portable sleep monitoring can accurately diagnose sleep apnea in hospitalized patients with heart failure and may promote early initiation of treatment. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  13. Assessing assay agreement estimation for multiple left-censored data: a multiple imputation approach.

    PubMed

    Lapidus, Nathanael; Chevret, Sylvie; Resche-Rigon, Matthieu

    2014-12-30

    Agreement between two assays is usually based on the concordance correlation coefficient (CCC), estimated from the means, standard deviations, and correlation coefficient of these assays. However, such data will often suffer from left-censoring because of lower limits of detection of these assays. To handle such data, we propose to extend a multiple imputation approach by chained equations (MICE) developed in a close setting of one left-censored assay. The performance of this two-step approach is compared with that of a previously published maximum likelihood estimation through a simulation study. Results show close estimates of the CCC by both methods, although the coverage is improved by our MICE proposal. An application to cytomegalovirus quantification data is provided. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Comparison of Collection Methods for Fecal Samples for Discovery Metabolomics in Epidemiologic Studies.

    PubMed

    Loftfield, Erikka; Vogtmann, Emily; Sampson, Joshua N; Moore, Steven C; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi

    2016-11-01

    The gut metabolome may be associated with the incidence and progression of numerous diseases. The composition of the gut metabolome can be captured by measuring metabolite levels in the feces. However, there are little data describing the effect of fecal sample collection methods on metabolomic measures. We collected fecal samples from 18 volunteers using four methods: no solution, 95% ethanol, fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT). One set of samples was frozen after collection (day 0), and for 95% ethanol, FOBT, and FIT, a second set was frozen after 96 hours at room temperature. We evaluated (i) technical reproducibility within sample replicates, (ii) stability after 96 hours at room temperature for 95% ethanol, FOBT, and FIT, and (iii) concordance of metabolite measures with the putative "gold standard," day 0 samples without solution. Intraclass correlation coefficients (ICC) estimating technical reproducibility were high for replicate samples for each collection method. ICCs estimating stability at room temperature were high for 95% ethanol and FOBT (median ICC > 0.87) but not FIT (median ICC = 0.52). Similarly, Spearman correlation coefficients (r s ) estimating metabolite concordance with the "gold standard" were higher for 95% ethanol (median r s = 0.82) and FOBT (median r s = 0.70) than for FIT (median r s = 0.40). Metabolomic measurements appear reproducible and stable in fecal samples collected with 95% ethanol or FOBT. Concordance with the "gold standard" is highest with 95% ethanol and acceptable with FOBT. Future epidemiologic studies should collect feces using 95% ethanol or FOBT if interested in studying fecal metabolomics. Cancer Epidemiol Biomarkers Prev; 25(11); 1483-90. ©2016 AACR. ©2016 American Association for Cancer Research.

  15. Applying new Magee equations for predicting the Oncotype Dx recurrence score.

    PubMed

    Sughayer, Maher; Alaaraj, Rolla; Alsughayer, Ahmad

    2018-04-24

    Breast cancer is one of the most prevalent cancers in women. Oncotype Dx is a multi-gene assay frequently used to predict the recurrence risk for estrogen receptor-positive early breast cancer, with values < 18 considered low risk; ≥ 18 and ≤ 30, intermediate risk; and > 30, high risk. Patients at a high risk for recurrence are more likely to benefit from chemotherapy treatment. In this study, clinicopathological parameters for 37 cases of early breast cancer with available Oncotype Dx results were used to estimate the recurrence score using the three new Magee equations. Correlation studies with Oncotype Dx results were performed. Applying the same cutoff points as Oncotype Dx, patients were categorized into low-, intermediate- and high-risk groups according to their estimated recurrence scores. Pearson correlation coefficient (R) values between estimated and actual recurrence score were 0.73, 0.66, and 0.70 for Magee equations 1, 2 and 3, respectively. The concordance values between actual and estimated recurrence scores were 57.6%, 52.9%, and 57.6% for Magee equations 1, 2 and 3, respectively. Using standard pathologic measures and immunohistochemistry scores in these three linear Magee equations, most low and high recurrence risk cases can be predicted with a strong positive correlation coefficient, high concordance and negligible two-step discordance. Magee equations are user-friendly and can be used to predict the recurrence score in early breast cancer cases.

  16. The Parenting to Reduce Adolescent Depression and Anxiety Scale: Assessing parental concordance with parenting guidelines for the prevention of adolescent depression and anxiety disorders

    PubMed Central

    Cardamone-Breen, Mairead C.; Jorm, Anthony F.; Lawrence, Katherine A.; Mackinnon, Andrew J.

    2017-01-01

    Background Despite substantial evidence demonstrating numerous parental risk and protective factors for the development of adolescent depression and anxiety disorders, there is currently no single measure that assesses these parenting factors. To address this gap, we developed the Parenting to Reduce Adolescent Depression and Anxiety Scale (PRADAS) as a criterion-referenced measure of parental concordance with a set of evidence-based parenting guidelines for the prevention of adolescent depression and anxiety disorders. In this paper, we used a sample of Australian parents of adolescents to: (1) validate the PRADAS as a criterion-referenced measure; (2) examine parental concordance with the guidelines in the sample; and (3) examine correlates of parental concordance with the guidelines. Methods Seven hundred eleven parents completed the PRADAS, as well as two established parenting measures, and parent-report measures of adolescent depression and anxiety symptoms. Six hundred sixty adolescent participants (aged 12–15) also completed the symptom measures. Concordance with the guidelines was assessed via nine subscale scores and a total score. Reliability of the scores was assessed with an estimate of the agreement coefficient, as well as 1-month test-retest reliability. Convergent validity was examined via correlations between the scale and two established parenting measures. Results One proposed subscale was removed from the final version of the scale, resulting in a total of eight subscales. Reliability was high for the total score, and acceptable to high for seven of the eight subscales. One-month test-retest reliability was acceptable to high for the total score. Convergent validity was supported by moderate to high correlations with two established measures of parenting. Overall, rates of parental concordance with the guidelines were low in our sample. Higher scores were associated with being female and higher levels of parental education. Greater parental concordance with the guidelines was associated with fewer symptoms of depression and anxiety in adolescent participants. Discussion This initial validation study provides preliminary support for the reliability and validity of the PRADAS. The scale has potential for use in both clinical and research settings. It may be used to identify parents’ strengths and potential targets for intervention, and as an outcome measure in studies of preventive parenting interventions. PMID:28951815

  17. Copula based prediction models: an application to an aortic regurgitation study

    PubMed Central

    Kumar, Pranesh; Shoukri, Mohamed M

    2007-01-01

    Background: An important issue in prediction modeling of multivariate data is the measure of dependence structure. The use of Pearson's correlation as a dependence measure has several pitfalls and hence application of regression prediction models based on this correlation may not be an appropriate methodology. As an alternative, a copula based methodology for prediction modeling and an algorithm to simulate data are proposed. Methods: The method consists of introducing copulas as an alternative to the correlation coefficient commonly used as a measure of dependence. An algorithm based on the marginal distributions of random variables is applied to construct the Archimedean copulas. Monte Carlo simulations are carried out to replicate datasets, estimate prediction model parameters and validate them using Lin's concordance measure. Results: We have carried out a correlation-based regression analysis on data from 20 patients aged 17–82 years on pre-operative and post-operative ejection fractions after surgery and estimated the prediction model: Post-operative ejection fraction = - 0.0658 + 0.8403 (Pre-operative ejection fraction); p = 0.0008; 95% confidence interval of the slope coefficient (0.3998, 1.2808). From the exploratory data analysis, it is noted that both the pre-operative and post-operative ejection fractions measurements have slight departures from symmetry and are skewed to the left. It is also noted that the measurements tend to be widely spread and have shorter tails compared to normal distribution. Therefore predictions made from the correlation-based model corresponding to the pre-operative ejection fraction measurements in the lower range may not be accurate. Further it is found that the best approximated marginal distributions of pre-operative and post-operative ejection fractions (using q-q plots) are gamma distributions. The copula based prediction model is estimated as: Post -operative ejection fraction = - 0.0933 + 0.8907 × (Pre-operative ejection fraction); p = 0.00008 ; 95% confidence interval for slope coefficient (0.4810, 1.3003). For both models differences in the predicted post-operative ejection fractions in the lower range of pre-operative ejection measurements are considerably different and prediction errors due to copula model are smaller. To validate the copula methodology we have re-sampled with replacement fifty independent bootstrap samples and have estimated concordance statistics 0.7722 (p = 0.0224) for the copula model and 0.7237 (p = 0.0604) for the correlation model. The predicted and observed measurements are concordant for both models. The estimates of accuracy components are 0.9233 and 0.8654 for copula and correlation models respectively. Conclusion: Copula-based prediction modeling is demonstrated to be an appropriate alternative to the conventional correlation-based prediction modeling since the correlation-based prediction models are not appropriate to model the dependence in populations with asymmetrical tails. Proposed copula-based prediction model has been validated using the independent bootstrap samples. PMID:17573974

  18. Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.

    PubMed

    Akuffo, Kwadwo Owusu; Beatty, Stephen; Stack, Jim; Peto, Tunde; Leung, Irene; Corcoran, Laura; Power, Rebecca; Nolan, John M

    2015-12-01

    We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitometer and Spectralis, as part of the Central Retinal Enrichment Supplementation Trial (CREST; ISRCTN13894787). Baseline and 6-month study visits data were used for the analyses. Agreement was investigated at four different retinal eccentricities, graphically and using indices of agreement, including Pearson correlation coefficient (precision), accuracy coefficient, and concordance correlation coefficient (ccc). Agreement was poor between the Densitometer and Spectralis at all eccentricities, at baseline (e.g., at 0.25° eccentricity, accuracy = 0.63, precision = 0.35, ccc = 0.22) and at 6 months (e.g., at 0.25° eccentricity, accuracy = 0.52, precision = 0.43, ccc = 0.22). Agreement between the two devices was significantly greater for males at 0.5° and 1.0° of eccentricity. At all eccentricities, agreement was unaffected by cataract grade. In subjects with early AMD, MP measurements obtained using the Densitometer and Spectralis are not statistically comparable and should not be used interchangeably in either the clinical or research setting. Despite this lack of agreement, statistically significant increases in MP, following 6 months of supplementation with macular carotenoids, were detected with each device, confirming that these devices are capable of measuring change in MP within subjects over time. (http://www.controlled-trials.com number, ISRCTN13894787.).

  19. Concordance of vitamin D peripheral levels in infertile couples' partners.

    PubMed

    Paffoni, Alessio; Ferrari, Stefania; Mangiarini, Alice; Noli, Stefania; Bulfoni, Alessandro; Vigano, Paola; Parazzini, Fabio; Somigliana, Edgardo

    2017-08-01

    A large number of evidence supports the role of vitamin D insufficiency in both women and men infertility. However, no studies have evaluated the rate of concordance of vitamin D status between the partners. This finding might open new scenarios in the interpretation of the available data linking vitamin D insufficiency and infertility. In the present cross-sectional study, 103 consecutive infertile couples were recruited between April and May 2014. Both partners concomitantly provided a serum sample for the assessment of 25-hydroxy-vitamin D [25-(OH)-D]. Vitamin D insufficiency was defined as serum 25-(OH)-D <20 ng/ml. One hundred-fifty subjects (73 women and 77 males) were 25-(OH)-D insufficient, corresponding to a rate of 73%. Overall, concordance was observed in 73 couples (71%), thus higher than the expected 61% (0.732 + 0.272) based on chance (p = 0.007). The Pearson coefficient of correlation R2 between the partners of the couples was 0.52 (p < 0.001). No statistically significant differences emerged when evaluating the rate of 25-(OH)-D insufficiency according to the causes of infertility. Serum 25-(OH)-D correlates within the partners of infertile couples. Further evidence is warranted to determine the clinical relevance and possible clinical applications of this finding.

  20. Concord Grape Juice Polyphenols and Cardiovascular Risk Factors: Dose-Response Relationships

    PubMed Central

    Blumberg, Jeffrey B.; Vita, Joseph A.; Chen, C. -Y. Oliver

    2015-01-01

    Pure fruit juices provide nutritional value with evidence suggesting some of their benefits on biomarkers of cardiovascular disease risk may be derived from their constituent polyphenols, particularly flavonoids. However, few data from clinical trials are available on the dose-response relationship of fruit juice flavonoids to these outcomes. Utilizing the results of clinical trials testing single doses, we have analyzed data from studies of 100% Concord grape juice by placing its flavonoid content in the context of results from randomized clinical trials of other polyphenol-rich foods and beverages describing the same outcomes but covering a broader range of intake. We selected established biomarkers determined by similar methods for measuring flow-mediated vasodilation (FMD), blood pressure, platelet aggregation, and the resistance of low density lipoprotein cholesterol (LDL) to oxidation. Despite differences among the clinical trials in the treatment, subjects, and duration, correlations were observed between the dose and FMD. Inverse dose-response relationships, albeit with lower correlation coefficients, were also noted for the other outcomes. These results suggest a clear relationship between consumption of even modest serving sizes of Concord grape juice, flavonoid intake, and effects on risk factors for cardiovascular disease. This approach to dose-response relationships may prove useful for testing other individual foods and beverages. PMID:26633488

  1. Diffusion-weighted imaging of the prostate: should we use quantitative metrics to better characterize focal lesions originating in the peripheral zone?

    PubMed

    Pierre, Thibaut; Cornud, Francois; Colléter, Loïc; Beuvon, Frédéric; Foissac, Frantz; Delongchamps, Nicolas B; Legmann, Paul

    2018-05-01

    To compare inter-reader concordance and accuracy of qualitative diffusion-weighted (DW) PIRADSv2.0 score with those of quantitative DW-MRI for the diagnosis of peripheral zone prostate cancer. Two radiologists independently assigned a DW-MRI-PIRADS score to 92 PZ-foci, in 74 patients (64.3±5.6 years old; median PSA level: 8 ng/ml, normal DRE in 70 men). A standardised ADCmean and nine ADC-derived parameters were measured, including ADCratios with the whole-prostate (WP-ADCratio) or the mirror-PZ (mirror-ADCratio) as reference areas. Surgical histology and MRI-TRUS fusion-biopsy were the reference for tumours and benign foci, respectively. Inter-reader agreement was assessed by the Cohen-kappa-coefficient and the intraclass correlation coefficient (ICC). Univariate-multivariate regressions determined the most predictive factor for cancer. Fifty lesions were malignant. Inter-reader concordance was fair for qualitative assessment, but excellent for quantitative assessment for all quantitative variables. At univariate analysis, ADCmean, WP-ADCratio and WL-ADCmean performed equally, but significantly better than the mirror-ADCratio (p<0.001). At multivariate analysis, the only independent variable significantly associated with malignancy was the whole-prostate-ADCratio. At a cut-off value of 0.68, sensitivity was 94-90 % and specificity was 60-38 % for readers 1 and 2, respectively. The whole-prostate-ADCratio improved the qualitative inter-reader concordance and characterisation of focal PZ-lesions. • Inter-reader concordance of DW PI-RADSv2.0 score for PZ lesions was only fair. • Using a standardised ADCmean measurement and derived DW-quantitative parameters, concordance was excellent. • The whole-prostate ADCratio performed significantly better than the mirror-ADCratio for cancer detection. • At a cut-off of 0.68, sensitivity values of WP-ADCratio were 94-90 %. • The whole-prostate ADCratio may circumvent variations of ADC metrics across centres.

  2. Comparison between Measurements Obtained with three Different Perineometers

    PubMed Central

    Barbosa, Patrícia Brentegani; Franco, Maíra Menezes; de Oliveira Souza, Flaviane; Antônio, Flávia Ignácio; Montezuma, Thaís; Ferreira, Cristine Homsi Jorge

    2009-01-01

    OBJECTIVE: To analyze the results obtained in the evaluation of intra-vaginal pressure using three different brands of perineometers in nulliparous volunteers. MATERIALS AND METHODS: Twenty nulliparous women with no anatomical alterations and/or dysfunction of the pelvic floor were enrolled in our study. All the women had the ability to voluntarily contract their PFM (Pelvic Floor Muscles), as assessed by digital palpation. The intra-vaginal pressure was assessed using three different brands of perineometer (Neurodyn Evolution™, SensuPower™ and Peritron™). Each volunteer was evaluated on three alternate days by a single examiner using a single brand of perineometer on each day. In the assessment, the volunteers were required to pull (contract) their PFM in and up as strongly as possible 3 times and to sustain the contraction for 5 seconds, with an interval of 30 seconds between each pull. For the statistical analysis, a concordance correlation coefficient was used to compare the values that were obtained with each brand of perineometer. RESULTS: A moderate concordance (0.51) was found between the results from the Peritron™ and Neurodyn™ perineometers, a fair concordance (0.21) between the Peritron™ and SensuPower™ brands and a poor concordance (0.19) between the Neurodyn™ and SensuPower™ brands. CONCLUSION: The concordance of the measurements of the intra-vaginal pressure ranged from poor to moderate, suggesting that perineometers of different brands generate different results. PMID:19578656

  3. Validation of clinic weights from electronic health records against standardized weight measurements in weight loss trials.

    PubMed

    Xiao, Lan; Lv, Nan; Rosas, Lisa G; Au, David; Ma, Jun

    2017-02-01

    To validate clinic weights in electronic health records against researcher-measured weights for outcome assessment in weight loss trials. Clinic and researcher-measured weights from a published trial (BE WELL) were compared using Lin's concordance correlation coefficient, Bland and Altman's limits of agreement, and polynomial regression model. Changes in clinic and researcher-measured weights in BE WELL and another trial, E-LITE, were analyzed using growth curve modeling. Among BE WELL (n = 330) and E-LITE (n = 241) participants, 96% and 90% had clinic weights (mean [SD] of 5.8 [6.1] and 3.7 [3.9] records) over 12 and 15 months of follow-up, respectively. The concordance correlation coefficient was 0.99, and limits of agreement plots showed no pattern between or within treatment groups, suggesting overall good agreement between researcher-measured and nearest-in-time clinic weights up to 3 months. The 95% confidence intervals for predicted percent differences fell within ±3% for clinic weights within 3 months of the researcher-measured weights. Furthermore, the growth curve slopes for clinic and researcher-measured weights by treatment group did not differ significantly, suggesting similar inferences about treatment effects over time, in both trials. Compared with researcher-measured weights, close-in-time clinic weights showed high agreement and inference validity. Clinic weights could be a valid pragmatic outcome measure in weight loss studies. © 2017 The Obesity Society.

  4. Discordant inflammatory changes in the apophyseal and sacroiliac joints: serial observations in enthesitis-related arthritis.

    PubMed

    Bray, Timothy J P; Amies, Thomas; Vendhan, Kanimozhi; Humphries, Paul; Sen, Debajit; Ioannou, Yiannis; Hall-Craggs, Margaret A

    2016-09-01

    To determine the extent to which inflammation of the sacroiliac joints (SIJs) and apophyseal joints (AJs) changes concordantly after treatment in enthesitis-related arthritis (ERA). A retrospective study was performed with institutional review board approval. 31 young patients with ERA who had been scanned between March 2009 and November 2014 were included. All patients had post-contrast imaging of the SIJs and lumbar spine and short tau inversion-recovery (STIR) images of the SIJs. The severity of sacroiliitis was scored using a modification of an established technique, and inflammation of the AJs was evaluated using a recently described grading system. The changes in SIJ and AJ scores after treatment were classified as either concordant or discordant, and the proportion of scan pairs in these groups was recorded. In addition, the correlation between change in SIJ STIR score (Δnfla) and change in AJ score (ΔAJ) was assessed using Spearman's correlation coefficient. Of a total of 43 scan pairs, the changes in inflammation were concordant in 16 scan pairs and discordant in 27 scan pairs. There was no significant correlation between Δnfla and ΔAJ (R = 0.14, p = 0.37). Inflammatory changes in the SIJs and AJs are often discordant. This may be a reason why patients experience ongoing back pain despite apparent improvement in one or the other site. Inflammation may behave differently at different anatomical sites. The SIJs and AJs should both be imaged in patients with ERA with back pain.

  5. Validity of gestational age estimates by last menstrual period and neonatal examination compared to ultrasound in Vietnam.

    PubMed

    Deputy, Nicholas P; Nguyen, Phuong H; Pham, Hoa; Nguyen, Son; Neufeld, Lynnette; Martorell, Reynaldo; Ramakrishnan, Usha

    2017-01-11

    Accurate estimation of gestational age is important for both clinical and public health purposes. Estimates of gestational age using fetal ultrasound measurements are considered most accurate but are frequently unavailable in low- and middle-income countries. The objective of this study was to assess the validity of last menstrual period and Farr neonatal examination estimates of gestational age, compared to ultrasound estimates, in a large cohort of women in Vietnam. Data for this analysis come from a randomized, placebo-controlled micronutrient supplementation trial in Vietnam. We analyzed 912 women with ultrasound and prospectively-collected last menstrual period estimates of gestational age and 685 women with ultrasound and Farr estimates of gestational age. We used the Wilcoxon signed rank sum test to assess differences in gestational age estimated by last menstrual period or Farr examination compared to ultrasound and computed the intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC) to quantify agreement between methods. We computed the Kappa coefficient (κ) to quantify agreement in preterm, term and post-term classification. The median gestational age estimated by ultrasound was 273.9 days. Gestational age was slightly overestimated by last menstrual period (median 276.0 days, P < 0.001) and more greatly overestimated by Farr examination (median 286.7 days, P < 0.001). Gestational age estimates by last menstrual period and ultrasound were moderately correlated (ICC = 0.78) and concordant (CCC = 0.63), whereas gestational age estimates by Farr examination and ultrasound were weakly correlated (ICC = 0.26) and concordant (CCC = 0.05). Last menstrual period and ultrasound estimates of gestational age were within ± 14 days for 88.4% of women; Farr and ultrasound estimates were within ± 14 days for 55.8% of women. Last menstrual period and ultrasound estimates of gestational age had higher agreement in term classification (κ = 0.41) than Farr and ultrasound (κ = 0.05). In this study of women in Vietnam, we found last menstrual period provided a more accurate estimate of gestational age than the Farr examination when compared to ultrasound. These findings provide useful information about the utility and accuracy of different methods to estimate gestational age and suggest last menstrual period may be preferred over Farr examination in settings where ultrasound is unavailable. The trial was registered at ClinicalTrials.Gov as NCT01665378 on August 13, 2012.

  6. Simulation Testing for Selection of Critical Care Medicine Trainees. A Pilot Feasibility Study.

    PubMed

    Cocciante, Adriano G; Nguyen, Martin N; Marane, Candida F; Panayiotou, Anita E; Karahalios, Amalia; Beer, Janet A; Johal, Navroop; Morris, John; Turner, Stacy; Hessian, Elizabeth C

    2016-04-01

    Selection of physicians into anesthesiology, intensive care, and emergency medicine training has traditionally relied on evaluation of curriculum vitae, letters of recommendation, and interviews, despite these methods being poor predictors of subsequent workplace performance. In this study, we evaluated the feasibility and face validity of incorporating assessment of nontechnical skills in simulation and personality traits into an existing junior doctor selection framework. Candidates short-listed for a critical care residency position were invited to participate in the study. On the interview day, consenting candidates participated in a simulation scenario and debriefing and completed a personality test (16 Personality Factor Questionnaire) and a survey. Timing of participants' progression through the stations and faculty staff numbers were evaluated. Nontechnical skills were evaluated and candidates ranked using the Ottawa Crisis Resource Management Global Rating Scale (Ottawa GRS). Nontechnical skills ranking and traditional selection method ranking were compared using the concordance correlation coefficient. Interrater reliability was assessed using the concordance correlation coefficient. Thirteen of 20 eligible participants consented to study inclusion. All participants completed the necessary stations without significant time delays. Eighteen staff members were required to conduct interviews, simulation, debriefing, and personality testing. Participants rated the simulation station to be acceptable, fair, and relevant and as providing an opportunity to demonstrate abilities. Personality testing was rated less fair, less relevant, and less acceptable, and as giving less opportunity to demonstrate abilities. Participants reported that simulation was equally as stressful as the interview, whereas personality testing was rated less stressful. Assessors rated both personality testing and simulation as acceptable and able to provide additional information about candidates. The Ottawa GRS showed moderate interrater concordance. There was moderate concordance between rankings based on traditional selection methods and Ottawa GRS rankings (ρ = 0.52; 95% confidence interval, -0.02 to 0.82; P = 0.06). A multistation selection process involving interviews, simulation, and personality testing is feasible and has face validity. A potential barrier to adoption is the high number of faculty required to conduct the process.

  7. Obtaining the mean relative weights of the cost of care in Catalonia (Spain): retrospective application of the adjusted clinical groups case-mix system in primary health care.

    PubMed

    Sicras-Mainar, Antoni; Velasco-Velasco, Soledad; Navarro-Artieda, Ruth; Aguado Jodar, Alba; Plana-Ripoll, Oleguer; Hermosilla-Pérez, Eduardo; Bolibar-Ribas, Bonaventura; Prados-Torres, Alejandra; Violan-Fors, Concepción

    2013-04-01

    The study aims to obtain the mean relative weights (MRWs) of the cost of care through the retrospective application of the adjusted clinical groups (ACGs) in several primary health care (PHC) centres in Catalonia (Spain) in routine clinical practice. This is a retrospective study based on computerized medical records. All patients attended by 13 PHC teams in 2008 were included. The principle measurements were: demographic variables (age and sex), dependent variables (number of diagnoses and total costs), and case-mix or co-morbidity variables (International Classification of Primary Care). The costs model for each patient was established by differentiating the fix costs from the variable costs. In the bivariate analysis, the Student's t, analysis of variance, chi-squared, Pearson's linear correlation and Mann-Whitney-Wilcoxon tests were used. In order to compare the MRW of the present study with those of the United States (US), the concordance [intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC)] and the correlation (coefficient of determination: R²) were measured. The total number of patients studied was 227,235, and the frequentation was 5.9 visits/habitant/year) and with a mean diagnoses number of 4.5 (3.2). The distribution of costs was €148.7 million, of which 29.1% were fixed costs. The mean total cost per patient/year was €654.2 (851.7), which was considered to be the reference MRW. Relationship between study-MRW and US-MRW: ICC was 0.40 [confidential interval (CI) 95%: 0.21-0.60] and the CCC was 0.42 (CI 95%: 0.35-0.49). The correlation between the US MRW and the MRW of the present study can be seen; the adjusted R² value is 0.691. The explanatory power of the ACG classification was 36.9% for the total costs. The R² of the total cost without considering outliers was 56.9%. The methodology has been shown appropriate for promoting the calculation of the MRW for each category of the classification. The results provide a possible practical application in PHC clinical management. © 2012 Blackwell Publishing Ltd.

  8. Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring.

    PubMed

    Ostenson, Jason; Robison, Ryan K; Zwart, Nicholas R; Welch, E Brian

    2017-09-01

    Magnetic resonance fingerprinting (MRF) pulse sequences often employ spiral trajectories for data readout. Spiral k-space acquisitions are vulnerable to blurring in the spatial domain in the presence of static field off-resonance. This work describes a blurring correction algorithm for use in spiral MRF and demonstrates its effectiveness in phantom and in vivo experiments. Results show that image quality of T1 and T2 parametric maps is improved by application of this correction. This MRF correction has negligible effect on the concordance correlation coefficient and improves coefficient of variation in regions of off-resonance relative to uncorrected measurements. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    PubMed

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  10. Evaluation of two portable meters for determination of blood triglyceride concentration in dogs.

    PubMed

    Kluger, Elissa K; Dhand, Navneet K; Malik, Richard; Ilkin, William J; Snow, David H; Govendir, Merran

    2010-02-01

    To evaluate agreement between 2 portable triglyceride meters and a veterinary laboratory for measurement of blood triglyceride concentrations in dogs and evaluate effects of Hct and blood volume analyzed. 97 blood samples collected from 60 dogs. Triglyceride concentrations were measured in blood by use of 2 meters and compared with serum triglyceride concentrations determined by a veterinary laboratory. Within- and between-day precision, accuracy, and effects of blood volume and Hct were analyzed. Accuracy of both meters varied with triglyceride concentration, although both accurately delineated dogs with triglyceride concentrations < 180 mg/dL versus > or = 180 mg/dL. One meter had results with excellent overall correlation with results of the standard laboratory method, with a concordance correlation coefficient of 0.94 and mean difference of 20.3 mg/dL. The other meter had a good overall concordance correlation coefficient of 0.86 with a higher absolute mean difference of -27.7 mg/dL. Results were only affected by blood volume; triglyceride concentrations determined via both meters were significantly lower when 7 microL of EDTA-anticoagulated blood was used, compared with larger volumes. 1 meter had greater accuracy in the range of 140 to 400 mg/dL and was therefore well suited to detect hypertriglyceridemia. The other meter was accurate with triglyceride values < 140 mg/dL and yielded results similar to those of the veterinary laboratory in the range of 140 to 400 mg/dL, therefore being suitable for determination of triglyceride concentrations in nonfed dogs and dogs with mildly high concentrations.

  11. Handheld echocardiography during hospitalization for acute myocardial infarction.

    PubMed

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  12. [Concordance among invasive diagnostic procedures for Helicobacter pylori infection in adults].

    PubMed

    Sánchez-Cuén, Jaime Alberto; Canizalez-Román, Vicente Adrián; León-Sicairos, Nidia Maribel; Irineo-Cabrales, Ana Bertha; Bernal-Magaña, Gregorio

    2015-01-01

    Compare the strength of concordance between culture, histology, rapid urease test for diagnosis of Helicobacter pylori infection and histopathological findings relationship and frequency of positivity among such diagnostic procedures. Diagnostic test study. The study population were subjects with endoscopy and take samples of gastric antral. Rapid urease test (one sample), histology (two samples) and culture (two samples), and histopathological findings of gastric mucosa were performed. Statistical design with Student's t, Fisher exact test, Kappa coefficient. We reviewed 108 subjects, 28 (25.9%) men, 80 (74.1%) women, mean age was 49.1 years (SD 15.1). The Kappa coefficient was 0.729 and 0.377 between culture with histology and rapid urease test, respectively; likewise the Kappa coefficient was 0.565 between histology and rapid urease test. The strength of concordance was higher between histology with culture and rapid urease test; the most recommended being histology in clinical practice for the detection of Helicobacter pylori infection.

  13. Retrospective study

    PubMed Central

    Lu, Chao; Lv, Xueyou; Lin, Yiming; Li, Dejian; Chen, Lihua; Ji, Feng; Li, Youming; Yu, Chaohui

    2016-01-01

    Abstract Conventional forceps biopsy (CFB) is the most popular way to screen for gastric epithelial neoplasia (GEN) and adenocarcinoma of gastric epithelium. The aim of this study was to compare the diagnostic accuracy between conventional forceps biopsy and endoscopic submucosal dissection (ESD). Four hundred forty-four patients who finally undertook ESD in our hospital were enrolled from Jan 1, 2009 to Sep 1, 2015. We retrospectively assessed the characteristics of pathological results of CFB and ESD. The concordance rate between CFB and ESD specimens was 68.92% (306/444). Men showed a lower concordance rate (63.61% vs 79.33%; P = 0.001) and concordance patients were younger (P = 0.048). In multivariate analysis, men significantly had a lower concordance rate (coefficient −0.730, P = 0.002) and a higher rate of pathological upgrade (coefficient −0.648, P = 0.015). Locations of CFB did not influence the concordance rate statistically. The concordance rate was relatively high in our hospital. According to our analysis, old men plus gastric fundus or antrum of CFB were strongly suggested to perform ESD if precancerous lesions were found. And young women with low-grade intraepithelial neoplasia could select regular follow-up. PMID:27472723

  14. Long-term stability of CMV DNA in human breast milk.

    PubMed

    Sam, Soya S; Ingersoll, Jessica; Racsa, Lori D; Caliendo, Angela M; Racsa, Patrick N; Igwe, Doris; Abdul-Ali, Deborah; Josephson, Cassandra; Kraft, Colleen S

    2018-05-01

    Human cytomegalovirus (CMV) is the leading cause of intrauterine and perinatal viral infection. The most common route of CMV transmission in newborns is through breastmilk and this can lead to infant morbidity and mortality. Breast milk that has been frozen for an extended period may need to be tested for CMV DNA to determine the source of infection. It has been a challenge for clinical laboratories to ensure the stability of CMV DNA in frozen breast milk for accurate viral load measurement. To evaluate the stability of CMV DNA in breast milk by testing quantitative viral loads over a 28-day period for breast milk stored at 4 °C and a 90-day period for breast milk stored at -20 °C. Baseline viral loads were determined on day 0 and the samples stored at 4 °C underwent extraction and amplification at four time points, up to 28 days. The samples stored at -20 °C underwent extraction and amplification at five time points up to 90 days. Log 10 values were calculated and t-test, Pearson's coefficient, and concordance correlation coefficient were calculated. There was no statistically significant difference between the time points by t-test, and correlation coefficients showed greater than 90% concordance for days 0 and 28 as well as days 0 and 90 at both storage temperatures tested. The concentration of CMV DNA in breast milk was stable for 28 days at 4 °C and 90 days at -20 °C as the concentrations did not differ significantly from the baseline viral loads. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Performance comparison of new generation HCV core antigen test versus HCV RNA test in management of hepatitis C virus infection.

    PubMed

    Çetiner, Salih; Çetin Duran, Alev; Kibar, Filiz; Yaman, Akgün

    2017-06-01

    The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 10 3 IU/mL. On the contrary, the correlation reached significance for the values higher than 10 3 IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 10 3 IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Predicting enteric methane emission of dairy cows with milk Fourier-transform infrared spectra and gas chromatography-based milk fatty acid profiles.

    PubMed

    van Gastelen, S; Mollenhorst, H; Antunes-Fernandes, E C; Hettinga, K A; van Burgsteden, G G; Dijkstra, J; Rademaker, J L W

    2018-06-01

    The objective of the present study was to compare the prediction potential of milk Fourier-transform infrared spectroscopy (FTIR) for CH 4 emissions of dairy cows with that of gas chromatography (GC)-based milk fatty acids (MFA). Data from 9 experiments with lactating Holstein-Friesian cows, with a total of 30 dietary treatments and 218 observations, were used. Methane emissions were measured for 3 consecutive days in climate respiration chambers and expressed as production (g/d), yield (g/kg of dry matter intake; DMI), and intensity (g/kg of fat- and protein-corrected milk; FPCM). Dry matter intake was 16.3 ± 2.18 kg/d (mean ± standard deviation), FPCM yield was 25.9 ± 5.06 kg/d, CH 4 production was 366 ± 53.9 g/d, CH 4 yield was 22.5 ± 2.10 g/kg of DMI, and CH 4 intensity was 14.4 ± 2.58 g/kg of FPCM. Milk was sampled during the same days and analyzed by GC and by FTIR. Multivariate GC-determined MFA-based and FTIR-based CH 4 prediction models were developed, and subsequently, the final CH 4 prediction models were evaluated with root mean squared error of prediction and concordance correlation coefficient analysis. Further, we performed a random 10-fold cross validation to calculate the performance parameters of the models (e.g., the coefficient of determination of cross validation). The final GC-determined MFA-based CH 4 prediction models estimate CH 4 production, yield, and intensity with a root mean squared error of prediction of 35.7 g/d, 1.6 g/kg of DMI, and 1.6 g/kg of FPCM and with a concordance correlation coefficient of 0.72, 0.59, and 0.77, respectively. The final FTIR-based CH 4 prediction models estimate CH 4 production, yield, and intensity with a root mean squared error of prediction of 43.2 g/d, 1.9 g/kg of DMI, and 1.7 g/kg of FPCM and with a concordance correlation coefficient of 0.52, 0.40, and 0.72, respectively. The GC-determined MFA-based prediction models described a greater part of the observed variation in CH 4 emission than did the FTIR-based models. The cross validation results indicate that all CH 4 prediction models (both GC-determined MFA-based and FTIR-based models) are robust; the difference between the coefficient of determination and the coefficient of determination of cross validation ranged from 0.01 to 0.07. The results indicate that GC-determined MFA have a greater potential than FTIR spectra to estimate CH 4 production, yield, and intensity. Both techniques hold potential but may not yet be ready to predict CH 4 emission of dairy cows in practice. Additional CH 4 measurements are needed to improve the accuracy and robustness of GC-determined MFA and FTIR spectra for CH 4 prediction. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study.

    PubMed

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.

  18. Discordant inflammatory changes in the apophyseal and sacroiliac joints: serial observations in enthesitis-related arthritis

    PubMed Central

    Amies, Thomas; Vendhan, Kanimozhi; Humphries, Paul; Sen, Debajit; Ioannou, Yiannis; Hall-Craggs, Margaret A

    2016-01-01

    Objective: To determine the extent to which inflammation of the sacroiliac joints (SIJs) and apophyseal joints (AJs) changes concordantly after treatment in enthesitis-related arthritis (ERA). Methods: A retrospective study was performed with institutional review board approval. 31 young patients with ERA who had been scanned between March 2009 and November 2014 were included. All patients had post-contrast imaging of the SIJs and lumbar spine and short tau inversion-recovery (STIR) images of the SIJs. The severity of sacroiliitis was scored using a modification of an established technique, and inflammation of the AJs was evaluated using a recently described grading system. The changes in SIJ and AJ scores after treatment were classified as either concordant or discordant, and the proportion of scan pairs in these groups was recorded. In addition, the correlation between change in SIJ STIR score (Δnfla) and change in AJ score (ΔAJ) was assessed using Spearman's correlation coefficient. Results: Of a total of 43 scan pairs, the changes in inflammation were concordant in 16 scan pairs and discordant in 27 scan pairs. There was no significant correlation between Δnfla and ΔAJ (R = 0.14, p = 0.37). Conclusion: Inflammatory changes in the SIJs and AJs are often discordant. This may be a reason why patients experience ongoing back pain despite apparent improvement in one or the other site. Advances in knowledge: Inflammation may behave differently at different anatomical sites. The SIJs and AJs should both be imaged in patients with ERA with back pain. PMID:27376529

  19. DEVELOPMENT AND VALIDATION OF TWO FOOD FREQUENCY QUESTIONNAIRES TO ASSESS GLUTEN INTAKE IN CHILDREN UP TO 36 MONTHS OF AGE.

    PubMed

    Crespo Escobar, Paula; Calvo Lerma, Joaquim; Hervas Marin, David; Donat Aliaga, Ester; Masip Simó, Etna; Polo Miquel, Begoña; Ribes Koninckx, Carmen

    2015-11-01

    precise information on gluten consumption is crucial for specifically studying the impact of gluten introduction and gluten intake in celiac disease development. Our aim was to develop and validate tools (food frequency questionnaires, FFQs) for the assessment of gluten consumption in Spanish children aged 7-36 months. a total of 342 children, who attended primary healthcare centers for routine health surveys or La Fe Hospital for minor health problems as well as healthy children (recruited in nurseries and primary schools) participated in this survey. We have developed two different FFQs (one for 7-12 months and other for 13-36 months). For validation, results from two FFQs were compared with results of 2-day food records and also with the gold standard 7-day records. The mean gluten intake obtained by the 2DR vs. FFQ and the 7DR vs. FFQ, were compared using the Bland Altman plot method and also Lin's concordance correlation coefficient. we found a good agreement between our FFQs and the 2DR and 7DR according to the results of both the Bland-Altman plots and Lin's concordance correlation coefficient. our two new FFQs are therefore the only validated questionnaires available to determine gluten consumption in Spanish children. They are user-friendly and offer excellent instruments to assess gluten intake in children up to 36 months of age. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  20. Relative Validity of a Diet History Questionnaire Against a Four-Day Weighed Food Record among Older Men in Australia: The Concord Health and Ageing in Men Project (CHAMP).

    PubMed

    Rosilene, W V R; Cumming, R; Travison, T; Blyth, F; Naganathan, V; Allman-Farinelli, M; Hirani, V

    2015-06-01

    To evaluate the relative validity of the diet history questionnaire (DHQ) used in the Concord Health and Ageing in Men Project (CHAMP) against a four-day weighed food record (4dWFR) as the reference method. Detailed DHQ followed by a 4dWFR were completed between July 2012 and October of 2013. Burwood, Canada Bay and Strathfield in Sydney, Australia. Fifty six community- dwelling men aged 75 years and over (mean=79 years). DHQ estimates of intakes were generally higher than estimates from 4dWFR. Differences between the two methods were generally less than 20% with the exception of β-carotene (37%). Fixed and proportional biases were only present for retinol, β-carotene, magnesium, phosphorus and percentage of energy from protein; however, 95% limits of agreement were in some cases wide. Pearson correlation coefficient of log-transformed unadjusted values ranged from 0.15 (zinc) to 0.70 (alcohol), and from 0.06 (iron) to 0.63 (thiamin) after energy-adjustment. Spearman's correlation coefficients ranged from 0.16 (zinc) to 0.80 (alcohol) before energy adjustment, and from 0.15(zinc) to 0.81(alcohol) after energy adjustment. Our findings suggest that the DHQ used in CHAMP to measure the nutritional intake of its participants is appropriate to this age group and provides reasonably similar results to the 4dWFR for the majority of nutrients analysed.

  1. Clinical findings, rhinoscopy and histological evaluation of 54 dogs with chronic nasal disease.

    PubMed

    Pietra, Marco; Spinella, Giuseppe; Pasquali, Flavio; Romagnoli, Noemi; Bettini, Giuliano; Spadari, Alessandro

    2010-09-01

    Nasal diseases are very common in dogs and rhinoscopy is often required for a definitive diagnosis. Rhinoscopy, while superficial in nature, can guide the clinician to the final diagnosis. In this study, rhinoscopy was performed on 54 dogs with symptoms of chronic nasopharyngeal disease. The endoscopic diagnosis of neoplasia or chronic nasal inflammation was validated with histological examination of pathological samples, in order to evaluate the degree of concordance between endoscopic findings and histological diagnosis. The agreement between endoscopy and histology was tested by application of Cohen's kappa coefficient. We conclude that correlation between endoscopic results and histological diagnosis, expressed by a Cohen's kappa coefficient of 0.73, is only possible with a constant cooperation between the clinician and the pathologist.

  2. Retrospective study: The diagnostic accuracy of conventional forceps biopsy of gastric epithelial compared to endoscopic submucosal dissection (STROBE compliant).

    PubMed

    Lu, Chao; Lv, Xueyou; Lin, Yiming; Li, Dejian; Chen, Lihua; Ji, Feng; Li, Youming; Yu, Chaohui

    2016-07-01

    Conventional forceps biopsy (CFB) is the most popular way to screen for gastric epithelial neoplasia (GEN) and adenocarcinoma of gastric epithelium. The aim of this study was to compare the diagnostic accuracy between conventional forceps biopsy and endoscopic submucosal dissection (ESD).Four hundred forty-four patients who finally undertook ESD in our hospital were enrolled from Jan 1, 2009 to Sep 1, 2015. We retrospectively assessed the characteristics of pathological results of CFB and ESD.The concordance rate between CFB and ESD specimens was 68.92% (306/444). Men showed a lower concordance rate (63.61% vs 79.33%; P = 0.001) and concordance patients were younger (P = 0.048). In multivariate analysis, men significantly had a lower concordance rate (coefficient -0.730, P = 0.002) and a higher rate of pathological upgrade (coefficient -0.648, P = 0.015). Locations of CFB did not influence the concordance rate statistically.The concordance rate was relatively high in our hospital. According to our analysis, old men plus gastric fundus or antrum of CFB were strongly suggested to perform ESD if precancerous lesions were found. And young women with low-grade intraepithelial neoplasia could select regular follow-up.

  3. Comparison of scales for evaluating premenstrual symptoms in women using oral contraceptives.

    PubMed

    Coffee, Andrea L; Kuehl, Thomas J; Sulak, Patricia J

    2008-05-01

    To compare two scales used in research to evaluate daily premenstrual mood symptoms during use of a monophasic oral contraceptive. Subanalysis of data from a prospective study. University-affiliated medical center. SUBJECTS; One hundred two reproductive-aged (18-48 yrs) women taking a monophasic oral contraceptive containing ethinyl estradiol and drospirenone in the standard 21-7 fashion (21 days of hormones followed by 7 days of placebo), and who had self-identified premenstrual symptoms of headache, mood changes, or pelvic pain. Subjects completed a single-item questionnaire, the Scott & White Daily Diary of Symptoms, and a multiple-item questionnaire, the Penn State Daily Symptom Report (DSR), to assess their premenstrual symptoms. The Scott & White diary used a visual analog scale of 0-10 to assess pelvic pain, headache, and mood (a composite of anxiety, depression, and irritability). The Penn State DSR contained 17 items: 10 behavioral and seven physical components, each rated on a scale of 0-4, with one item that specifically rated mood swings. Scores from the two scales were compared by using Spearman correlation coefficients, the Kendall W for concordance, and linear regression of ranked sums for study cycles. The Scott & White mood score significantly correlated with the total of the 17 items on the Penn State DSR, as well as the 10 behavioral items, the seven physical items, and the single mood-swing item (p<0.0001); specific coefficients of concordance were 0.44, 0.23, 0.10, and 0.28, respectively, and R2 values were 0.39, 0.39, 0.30, and 0.34, respectively. The daily Scott & White mood score was positively correlated with all 17 elements of the Penn State DSR (0.25-0.57). The greatest correlation was seen with the mood-swing element. Both instruments demonstrated the same patterns during the 21-7 oral contraceptive cycle, with symptoms increasing immediately before and peaking during the 7-day hormone-free interval. A single-item daily mood score using a rating scale of 0-10 was concordant with a relatively complex 17-element symptom index and demonstrated the same pattern of change during cycles of oral contraception. The simple scoring system offers an advantage, especially in clinical studies of long duration.

  4. With or without spikes: localization of focal epileptic activity by simultaneous electroencephalography and functional magnetic resonance imaging

    PubMed Central

    Grouiller, Frédéric; Thornton, Rachel C.; Groening, Kristina; Spinelli, Laurent; Duncan, John S.; Schaller, Karl; Siniatchkin, Michael; Lemieux, Louis; Seeck, Margitta; Michel, Christoph M.

    2011-01-01

    In patients with medically refractory focal epilepsy who are candidates for epilepsy surgery, concordant non-invasive neuroimaging data are useful to guide invasive electroencephalographic recordings or surgical resection. Simultaneous electroencephalography and functional magnetic resonance imaging recordings can reveal regions of haemodynamic fluctuations related to epileptic activity and help localize its generators. However, many of these studies (40–70%) remain inconclusive, principally due to the absence of interictal epileptiform discharges during simultaneous recordings, or lack of haemodynamic changes correlated to interictal epileptiform discharges. We investigated whether the presence of epilepsy-specific voltage maps on scalp electroencephalography correlated with haemodynamic changes and could help localize the epileptic focus. In 23 patients with focal epilepsy, we built epilepsy-specific electroencephalographic voltage maps using averaged interictal epileptiform discharges recorded during long-term clinical monitoring outside the scanner and computed the correlation of this map with the electroencephalographic recordings in the scanner for each time frame. The time course of this correlation coefficient was used as a regressor for functional magnetic resonance imaging analysis to map haemodynamic changes related to these epilepsy-specific maps (topography-related haemodynamic changes). The method was first validated in five patients with significant haemodynamic changes correlated to interictal epileptiform discharges on conventional analysis. We then applied the method to 18 patients who had inconclusive simultaneous electroencephalography and functional magnetic resonance imaging studies due to the absence of interictal epileptiform discharges or absence of significant correlated haemodynamic changes. The concordance of the results with subsequent intracranial electroencephalography and/or resection area in patients who were seizure free after surgery was assessed. In the validation group, haemodynamic changes correlated to voltage maps were similar to those obtained with conventional analysis in 5/5 patients. In 14/18 patients (78%) with previously inconclusive studies, scalp maps related to epileptic activity had haemodynamic correlates even when no interictal epileptiform discharges were detected during simultaneous recordings. Haemodynamic changes correlated to voltage maps were spatially concordant with intracranial electroencephalography or with the resection area. We found better concordance in patients with lateral temporal and extratemporal neocortical epilepsy compared to medial/polar temporal lobe epilepsy, probably due to the fact that electroencephalographic voltage maps specific to lateral temporal and extratemporal epileptic activity are more dissimilar to maps of physiological activity. Our approach significantly increases the yield of simultaneous electroencephalography and functional magnetic resonance imaging to localize the epileptic focus non-invasively, allowing better targeting for surgical resection or implantation of intracranial electrode arrays. PMID:21752790

  5. Procedural validity of the AUDADIS-5 depression, anxiety and post-traumatic stress disorder modules: substance abusers and others in the general population*

    PubMed Central

    Hasin, Deborah S.; Shmulewitz, Dvora; Stohl, Malka; Greenstein, Eliana; Aivadyan, Christina; Morita, Kara; Saha, Tulshi; Aharonovich, Efrat; Jung, Jeesun; Zhang, Haitao; Nunes, Edward V.; Grant, Bridget F.

    2016-01-01

    Background Little is known about the procedural validity of lay-administered, fully-structured assessments of depressive, anxiety and post-traumatic stress (PTSD) disorders in the general population as determined by comparison to clinical re-appraisal, and whether this differs between current regular substance abusers and others. We evaluated the procedural validity of the Alcohol Use Disorder and Associated Disabilities Interview Schedule, DSM-5 Version (AUDADIS-5) assessment of these disorders through clinician re-interviews. Methods Test-retest design among respondents from the National Epidemiologic Survey on Alcohol and Related Conditions-III (NESARC-III): (264 current regular substance abusers, 447 others). Clinicians blinded to AUDADIS-5 results administered the semi-structured Psychiatric Research Interview for Substance and Mental Disorders, DSM-5 version (PRISM-5). AUDADIS-5/PRISM-5 concordance was indicated by kappa (κ) for diagnoses and intraclass correlation coefficients (ICC) for dimensional measures (DSM-5 symptom or criterion counts). Results were compared between current regular substance abusers and others. Results AUDADIS-5 and PRISM-5 concordance for DSM-5 depressive disorders, anxiety disorders and PTSD was generally fair to moderate (κ =0.24–0.59), with concordance on dimensional scales much better (ICC=0.53–0.81). Concordance differed little between regular substance abusers and others. Conclusions AUDADIS-5/PRISM-5 concordance indicated procedural validity for the AUDADIS-5 among substance abusers and others, suggesting that AUDADIS-5 diagnoses of DSM-5 depressive, anxiety and PTSD diagnoses are informative measures in both groups in epidemiologic studies. The stronger concordance on dimensional measures supports the current movement towards dimensional psychopathology measures, suggesting that such measures provide important information for research in the NESARC-III and other datasets, and possibly for clinical purposes as well. PMID:25939727

  6. Comparing 15D Valuation Studies in Norway and Finland-Challenges When Combining Information from Several Valuation Tasks.

    PubMed

    Michel, Yvonne Anne; Augestad, Liv Ariane; Rand, Kim

    2018-04-01

    The 15D is a generic preference-based health-related quality-of-life instrument developed in Finland. Values for the 15D instrument are estimated by combining responses to three distinct valuation tasks. The impact of how these tasks are combined is relatively unexplored. To compare 15D valuation studies conducted in Norway and Finland in terms of scores assigned in the valuation tasks and resulting value algorithms, and to discuss the contributions of each task and the algorithm estimation procedure to observed differences. Norwegian and Finnish scores from the three valuation tasks were compared using independent samples t tests and Lin concordance correlation coefficients. Covariance between tasks was assessed using Pearson product-moment correlations. Norwegian and Finnish value algorithms were compared using concordance correlation coefficients, total ranges, and ranges for individual dimensions. Observed differences were assessed using minimal important difference. Mean scores in the main valuation task were strikingly similar between the two countries, whereas the final value algorithms were less similar. The largest differences between Norway and Finland were observed for depression, vision, and mental function. 15D algorithms are a product of combining scores from three valuation tasks by use of methods involving multiplication. This procedure used to combine scores from the three tasks by multiplication serves to amplify variance from each task. From relatively similar responses in Norway and Finland, diverging value algorithms are created. We propose to simplify the 15D algorithm estimation procedure by using only one of the valuation tasks. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  7. Use of the script concordance approach to evaluate clinical reasoning in food-ruminant practitioners.

    PubMed

    Dufour, Simon; Latour, Sylvie; Chicoine, Yvan; Fecteau, Gilles; Forget, Sylvain; Moreau, Jean; Trépanier, André

    2012-01-01

    A script concordance test (SCT) was developed measuring clinical reasoning of food-ruminant practitioners for whom potential clinical competence difficulties were identified by their provincial professional organization. The SCT was designed to be used as part of a broader evaluation procedure. A scoring key was developed based on answers from a reference panel of 12 experts and using the modified aggregate method commonly used for SCTs. A convenient sample of 29 food-ruminant practitioners was constituted to assess the reliability and precision of the SCT and to determine a fair threshold value for success. Cronbach's α coefficients were computed to evaluate internal reliability. To evaluate SCT precision, a test-retest methodology was used and measures of agreement beyond chance were computed at question and test levels. After optimization, the 36-question SCT yielded acceptable internal reliability (Cronbach's α=0.70). Precision of the SCT at question level was excellent with 33 questions (92%) yielding moderate to almost perfect agreement between administrations. At test level, fair agreement (concordance correlation coefficient=0.32) was observed between administrations. A slight SCT score improvement (M=+2.8 points) on the second administration was in part responsible for some of the disagreement and was potentially a result of an adaptation to the SCT format. Scores distribution was used to determine a fair threshold value for success, while considering the underlying objectives of the examination. The data suggest that the developed SCT can be used as a reliable and precise measurement of clinical reasoning of food-ruminant practitioners.

  8. Concordance and interchangeability of biometric measurements of ocular axial length in patients awaiting cataract surgery.

    PubMed

    Martín-Serrano, María José; Roman-Ortiz, Carmen; Villa-Sáez, M Luz; Labrador-Castellanos, M Purificación; Blanco-Carrasco, Rosario; Lozano-Ballesteros, Felicidad; Pedraza-Martín, Carmen; José-Herrero, M Teresa San; López-Ropero, Ana M; Tenías Burillo, José María

    2014-01-01

    To estimate in patients awaiting cataract surgery the concordance and interchangeability of axial eye length measurements performed with the aid of various biometric methods (optical or ultrasonic) by different operators (nurses) at different times during the period prior to surgery. We selected 182 consecutive eyes from 91 patients.Ocular axial length was measured with the aid of 2 methods (IOLMaster® and Ocuscan®) by 9 randomly allocated technicians at 2 different times during the waiting period. The concordance between measurements was evaluated by means of the intraclass correlation coefficient (ICC); the interchangeability of the results was assessed with Bland Altman plots and Passing and Bablok regression. The measurements were consistent between biometric methods (ICC 0.975, 95% confidence interval [CI] 0.968 to 0.980) and measurement dates (ICC 0.996, 95% CI 0.995 to 0.997). Interobserver agreement was more heterogeneous (ICC range 0.844 to 0.998). No systematic errors were observed among the various biometric methods and measurement dates. Because measurement of axial length in phakic patients may be technician-dependent, the technician's experience should be noted in the protocols of ophthalmology services.

  9. Rating scale for psychogenic nonepileptic seizures: scale development and clinimetric testing.

    PubMed

    Cianci, Vittoria; Ferlazzo, Edoardo; Condino, Francesca; Mauvais, Hélène Somma; Farnarier, Guy; Labate, Angelo; Latella, Maria Adele; Gasparini, Sara; Branca, Damiano; Pucci, Franco; Vazzana, Francesco; Gambardella, Antonio; Aguglia, Umberto

    2011-06-01

    Our aim was to develop a clinimetric scale evaluating motor phenomena, associated features, and severity of psychogenic nonepileptic seizures (PNES). Sixty video/EEG-recorded PNES induced by suggestion maneuvers were evaluated. We examined the relationship between results from this scale and results from the Clinical Global Impression (CGI) scale to validate this technique. Interrater reliabilities of the PNES scale for three raters were analyzed using the AC1 statistic, Kendall's coefficient of concordance (KCC), and intraclass correlation coefficients (ICCs). The relationship between the CGI and PNES scales was evaluated with Spearman correlations. The AC1 statistic demonstrated good interrater reliability for each phenomenon analyzed (tremor/oscillation, tonic; clonic/jerking, hypermotor/agitation, atonic/akinetic, automatisms, associated features). KCC and the ICC showed moderate interrater agreement for phenomenology, associated phenomena, and total PNES scores. Spearman's correlation of mean CGI score with mean total PNES score was 0.69 (P<0.001). The scale described here accurately evaluates the phenomenology of PNES and could be used to assess and compare subgroups of patients with PNES. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Concordance between Self-Reports and Medicare Claims among Participants in a National Study of Chronic Disease Self-Management Program.

    PubMed

    Jiang, Luohua; Zhang, Ben; Smith, Matthew Lee; Lorden, Andrea L; Radcliff, Tiffany A; Lorig, Kate; Howell, Benjamin L; Whitelaw, Nancy; Ory, Marcia G

    2015-01-01

    To evaluate the concordance between self-reported data and variables obtained from Medicare administrative data in terms of chronic conditions and health care utilization. Retrospective observational study. We analyzed data from a sample of Medicare beneficiaries who were part of the National Study of Chronic Disease Self-Management Program (CDSMP) and were eligible for the Centers for Medicare and Medicaid Services (CMS) pilot evaluation of CDSMP (n = 119). Self-reported and Medicare claims-based chronic conditions and health care utilization were examined. Percent of consistent numbers, kappa statistic (κ), and Pearson's correlation coefficient were used to evaluate concordance. The two data sources had substantial agreement for diabetes and chronic obstructive pulmonary disease (COPD) (κ = 0.75 and κ = 0.60, respectively), moderate agreement for cancer and heart disease (κ = 0.50 and κ = 0.47, respectively), and fair agreement for depression (κ = 0.26). With respect to health care utilization, the two data sources had almost perfect or substantial concordance for number of hospitalizations (κ = 0.69-0.79), moderate concordance for ED care utilization (κ = 0.45-0.61), and generally low agreement for number of physician visits (κ ≤ 0.31). Either self-reports or claim-based administrative data for diabetes, COPD, and hospitalizations can be used to analyze Medicare beneficiaries in the US. Yet, caution must be taken when only one data source is available for other types of chronic conditions and health care utilization.

  11. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study

    PubMed Central

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329

  12. Clinical findings, rhinoscopy and histological evaluation of 54 dogs with chronic nasal disease

    PubMed Central

    Pietra, Marco; Pasquali, Flavio; Romagnoli, Noemi; Bettini, Giuliano; Spadari, Alessandro

    2010-01-01

    Nasal diseases are very common in dogs and rhinoscopy is often required for a definitive diagnosis. Rhinoscopy, while superficial in nature, can guide the clinician to the final diagnosis. In this study, rhinoscopy was performed on 54 dogs with symptoms of chronic nasopharyngeal disease. The endoscopic diagnosis of neoplasia or chronic nasal inflammation was validated with histological examination of pathological samples, in order to evaluate the degree of concordance between endoscopic findings and histological diagnosis. The agreement between endoscopy and histology was tested by application of Cohen's kappa coefficient. We conclude that correlation between endoscopic results and histological diagnosis, expressed by a Cohen's kappa coefficient of 0.73, is only possible with a constant cooperation between the clinician and the pathologist. PMID:20706033

  13. Reliability and validity of the Chinese pediatric voice handicap index.

    PubMed

    Liu, Kena; Liu, Shaofeng; Zhou, Zhou; Ren, Qinyi; Zhong, Jie; Luo, Renzhong; Qin, Huabiao; Zhang, Siyi; Ge, Pingjiang

    2018-02-01

    To evaluate the reliability and validity of the Chinese version of pediatric voice handicap index (pVHI). The original English version-pVHI was translated into Chinese. Parents of 52 children with voice dysphonia and 43 children with no history or symptoms of voice problems were asked to fill the Chinese pVHI questionnaires twice with an interval of 2 weeks. GRB (Grade, Roughness, Breathiness) scale was used for perceptual assessment by two otolaryngologists and one speech pathologist for each child's voice. The internal consistency was assessed using Cronbach's alpha coefficient. Pearson's correlation coefficient was used to evaluate the test-retest reliability. The Kendall's coefficient of concordance W was used to assess the consistency of GRB scores of 3 voice specialists. The nonparametric Mann-Whitney test was used to assess the differences between the dysphonia group and controls. The correlation between pVHI and GRB scores were assessed using Pearson's correlation coefficient. The internal consistency of total score and three subscales scores of Chinese pVHI were 0.788-0.944. The test-retest reliability was 0.631-0.887(P < .001). The pVHI scores of control group significantly were lower than the pathological group (P = .000). The GRB scores of 3 voice specialists have an excellent consistency (W = 0.694-0.807, P = .000). The pVHI scores positively correlated with GRB assessment (P < .01). The Chinese version of pVHI had a good reliability and validity. It can be applicable and useful supplementary tool for evaluating parents' perception of their children's dysphonia. Copyright © 2017. Published by Elsevier B.V.

  14. A semi-automated volumetric software for segmentation and perfusion parameter quantification of brain tumors using 320-row multidetector computed tomography: a validation study.

    PubMed

    Chae, Soo Young; Suh, Sangil; Ryoo, Inseon; Park, Arim; Noh, Kyoung Jin; Shim, Hackjoon; Seol, Hae Young

    2017-05-01

    We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual segmentation. Twenty-nine patients with pathologically proven brain tumors who underwent preoperative WBCTP between August 2012 and February 2015 were included. Three perfusion parameters, arterial flow (AF), equivalent blood volume (EBV), and Patlak flow (PF, which is a measure of permeability of capillaries), of brain tumors were generated by a commercial software and then quantified volumetrically by NPerfusion, which also semi-automatically segmented tumor boundaries. The quantification was validated by comparison with that of manual segmentation in terms of the concordance correlation coefficient and Bland-Altman analysis. With NPerfusion, we successfully performed segmentation and quantified whole volumetric perfusion parameters of all 29 brain tumors that showed consistent perfusion trends with previous studies. The validation of the perfusion parameter quantification exhibited almost perfect agreement with manual segmentation, with Lin concordance correlation coefficients (ρ c ) for AF, EBV, and PF of 0.9988, 0.9994, and 0.9976, respectively. On Bland-Altman analysis, most differences between this software and manual segmentation on the commercial software were within the limit of agreement. NPerfusion successfully performs segmentation of brain tumors and calculates perfusion parameters of brain tumors. We validated this semi-automated segmentation software by comparing it with manual segmentation. NPerfusion can be used to calculate volumetric perfusion parameters of brain tumors from WBCTP.

  15. Validation of a noninvasive maturity estimate relative to skeletal age in youth football players.

    PubMed

    Malina, Robert M; Dompier, Thomas P; Powell, John W; Barron, Mary J; Moore, Marguerite T

    2007-09-01

    To validate a non-invasive measure of biological maturity (percentage of predicted mature height at a given age) with an established indicator of maturity [skeletal age (SA)] in youth American football players. Cross-sectional. Two communities in central Michigan. 143 youth football players 9.27 to 14.24 years. Height and weight were measured, and hand-wrist radiographs were taken. SA assessed with the Fels method was the criterion measure of maturity status. Chronological age (CA), height, and weight of the player and midparent height were used to predict mature height; current height of the player was expressed as a percentage of his predicted mature height as a noninvasive estimate of biological maturity status. Boys' maturation was classified as late, on time, or early maturing on the basis of the difference between SA and CA and of present height expressed as a percentage of predicted mature height. Kappa coefficients and Spearman rank-order correlations were calculated. Characteristics of players concordant and discordant for maturity classification with SA and percentage of predicted mature height were compared with MANCOVA. Concordance between methods of maturity classification was 62%. The Kappa coefficient, 0.46 (95% CI 0.19 to 0.59) and Spearman rank-order correlation, rs = 0.52 (P < 0.001) were moderate. Players discordant for maturity status varied in midparent height and percentage of predicted mature height, but not in predicted mature height. Percentage of predicted mature height is a reasonably valid estimate of biological maturity status in this sample of youth football players.

  16. Heritability of Respiratory Infection with Pseudomonas aeruginosa in Cystic Fibrosis

    PubMed Central

    Green, Deanna M.; Collaco, J. Michael; McDougal, Kathryn E.; Naughton, Kathleen M.; Blackman, Scott M.; Cutting, Garry R.

    2013-01-01

    Objective To quantify the relative contribution of factors other than cystic fibrosis transmembrane conductance regulator genotype and environment on the acquisition of Pseudomonas aeruginosa (Pa) by patients with cystic fibrosis. Study design Lung infection with Pa and mucoid Pa was assessed using a co-twin study design of 44 monozygous (MZ) and 17 dizygous (DZ) twin pairs. Two definitions were used to establish infection: first positive culture and persistent positive culture. Genetic contribution to infection (ie, heritability) was estimated based on concordance analysis, logistic regression, and age at onset of infection through comparison of intraclass correlation coefficients. Results Concordance for persistent Pa infection was higher in MZ (0.83; 25 of 30 pairs) than DZ twins (0.45; 5 of 11 pairs), generating a heritability of 0.76. Logistic regression adjusted for age corroborated genetic control of persistent Pa infection. The correlation for age at persistent Pa infection was higher in MZ twins (0.589; 95% CI, 0.222-0.704) than in DZ twins (0.162; 95% CI, −0.352 to 0.607), generating a heritability of 0.85. Conclusion Genetic modifiers play a significant role in the establishment and timing of persistent Pa infection in individuals with cystic fibrosis. PMID:22364820

  17. Physical activity in climacteric women: comparison between self-reporting and pedometer.

    PubMed

    Colpani, Verônica; Spritzer, Poli Mara; Lodi, Ana Paula; Dorigo, Guilherme Gustavo; Miranda, Isabela Albuquerque Severo de; Hahn, Laiza Beck; Palludo, Luana Pedroso; Pietroski, Rafaela Lazzari; Oppermann, Karen

    2014-04-01

    To compare two methods of assessing physical activity in pre-, peri- and postmenopausal women. Cross-sectional study nested in a cohort of pre-, peri- and postmenopausal women in a city in Southern Brazil. The participants completed a questionnaire that included sociodemographic and clinical data. Physical activity was assessed using a digital pedometer and the International Physical Activity Questionnaire, short version. The participants were classified into strata of physical activity according to the instrument used. For statistical analysis, the Spearman correlation test, Kappa index, concordance coefficient and Bland-Altman plots were used. The concordance (k = 0110; p = 0.007) and the correlation (rho = 0.136, p = 0.02) between the International Physical Activity Questionnaire, short version, and pedometer were weak. In Bland-Altman plots, it was observed that differences deviate from zero value whether the physical activity is minimal or more intense. Comparing the two methods, the frequency of inactive women is higher when assessed by pedometer than by the International Physical Activity Questionnaire--short version, and the opposite occurs in active women. Agreement between the methods was weak. Although easy to use, Physical Activity Questionnaire--short version overestimates physical activity compared with assessment by pedometer.

  18. [Molecular typing of Leishmania (Leishmania) amazonensis and species of the subgenus Viannia associated with cutaneous and mucosal leishmaniasis in Colombia: A concordance study].

    PubMed

    Ovalle-Bracho, Clemencia; Camargo, Carolina; Díaz-Toro, Yira; Parra-Muñoz, Marcela

    2018-03-15

    Multilocus enzyme electrophoresis (MLEE) is the reference standard for the characterization of Leishmania species. The test is restricted to specialized laboratories due to its technical complexity, cost, and time required to obtain results. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) is used to identify Leishmania species. To establish the concordance between the two tests as identifying methods for circulating species in Colombia. A total of 96 isolates from patients with cutaneous or mucosal leishmaniasis were selected and identified by MLEE and PCR-RFLP with miniexon and hsp70 as the molecular targets, which were used sequentially. Restriction enzymes HaeIII and BccI were similarly applied. Cohen's kappa coefficient and the 95% confidence interval (CI) were calculated. The kappa coefficient and the 95% CI between MLEE and PCR-RFLP displayed "very good" concordance with a coefficient of 0.98 (CI95%: 0.98 to 1.00). The identified species were Leishmania Viannia braziliensis, Leishmania Viannia panamensis, Leishmania Viannia guyanensis and Leishmania Leishmania amazonensis. A total of 80 of the 96 isolates were sequenced and the results obtained by PCR-RFLP were confirmed. Due to the concordance obtained between tests results with the amplification of the genes miniexon and hsp70, PCR-RFLP is proposed as an alternative for identifying circulating Leishmania species in Colombia.

  19. In vitro comparison of water displacement method and 3 Tesla MRI for MR-volumetry of the olfactory bulb: which sequence is appropriate?

    PubMed

    Burmeister, Hartmut Peter; Möslein, Constanze; Bitter, Thomas; Fröber, Rosemarie; Herrmann, Karl-Heinz; Baltzer, Pascal Andreas Thomas; Gudziol, Hilmar; Dietzel, Matthias; Guntinas-Lichius, Orlando; Kaiser, Werner Alois

    2011-10-01

    Magnetic resonance imaging olfactory bulb (OB) volumetry (OBV) is already used as a complementary prognostic tool to assess olfactory disorders. However, a reference standard in imaging for OBV has not been established. The aim of this in vitro study was to compare volumetric results of different magnetic resonance sequences for OBV at 3 T to genuine OB volumes measured by water displacement. The volumes of 15 human cadaveric OBs were measured using the water displacement method in this institutional review board-approved prospective study. The magnetic resonance imaging protocol at 3 T included constructive interference in steady state (CISS), T2-weighted (T2w) three-dimensional (3D) sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE), T2w two-dimensional (2D) turbo spin-echo (TSE), and T1-weighted (T1w) 3D fast low-angle shot (FLASH) sequences. Two blinded observers independently performed two OB volumetric assessments per bulbus and sequence. Intraobserver and interobserver reliabilities were assessed by intraclass correlation coefficients. Bland-Altman plots were analyzed to evaluate systematic biases and concordance correlation coefficients to assess reproducibility. For both observers, intraclass correlation coefficient analysis yielded almost perfect results for intraobserver reliability (CISS, 0.94-0.98; T2w 3D SPACE, 0.93-0.98; T2w 2D TSE, 0.98-0.98; T1w 3D FLASH, 0.95-0.99). Interobserver reliability showed almost perfect agreement for all sequences (CISS, 0.98; T2w 3D SPACE, 0.89; T2w 2D TSE, 0.93; T1w 3D FLASH, 0.97). The CISS sequence yielded the highest mean concordance correlation coefficient (0.95) and the highest combination of precision (0.97) and accuracy (0.98) values. In comparison with the water displacement method, Bland-Altman analyses revealed the lowest systematic bias (-0.5%) for the CISS sequence, followed by T1w 3D FLASH (-1.3%), T2w 3D SPACE (-7.5%), and T2w 2D TSE (-10.9%) sequences. Compared to the water displacement method, the CISS sequence is suited best to validly and reliably measure OB volumes because of its highest values for accuracy and precision and lowest systematic bias. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of the activity of rheumatoid arthritis in clinical practice. Agreement between self-rated clinimetric evaluation and clinical evaluation with activity indexes: DAS28, CDAI and SDAI.

    PubMed

    Horta-Baas, Gabriel; Pérez Bolde-Hernández, Arturo; Hernández-Cabrera, María Fernanda; Vergara-Sánchez, Imelda; Romero-Figueroa, María Del Socorro

    2017-10-11

    To achieve control of rheumatoid arthritis (RA) it is necessary to be able to evaluate its activity. The American College of Rheumatology (ACR) recommends for this purpose indexes of activity that can be performed by the patient (PAS-II and RAPID-3) and IA including medical evaluation with laboratory studies (DAS28 and SDAI) or without them (CDAI). The objective was to analyze the concordance between self-rated clinimetric evaluation and clinimetric evaluation performed by the physician. Analytical cross-sectional study in 126 patients with RA. The agreement was evaluated through the weighted κ coefficient and the Krippendorff's α coefficient. The PAS-II and RAPID-3 significantly correlated with all variables included in the core set of measures recommended by the ACR/EULAR. The agreement between PAS-II and CDAI-SDAI was good (κ: 0.6, α: 0.61-0.62), and moderate with DAS28-ESR (κ: 0.53, α: 0.56). The concordance between RAPID-3 and CDAI-SDAI was moderate (κ: 0.55-0.57, α: 0.50-0.51), and moderate with DAS28-ESR (κ: 0.55, α: 0.53). When categorizing the activity in remission/low activity vs. moderate/severe activity, the agreement was greater with the PAS-II (0.59 vs. 0.34; P=.012). The good concordance between PAS-II and SDAI supports their use in clinical practice, especially if biomarkers of inflammation or the possibility of joint count are not available. However, in order to recommend its routine application in clinical practice, it is necessary to perform longitudinal studies that assess its responsiveness. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  1. The Female Sexual Function Index (FSFI): linguistic validation of the Italian version.

    PubMed

    Filocamo, Maria Teresa; Serati, Maurizio; Li Marzi, Vincenzo; Costantini, Elisabetta; Milanesi, Martina; Pietropaolo, Amelia; Polledro, Patrizio; Gentile, Barbara; Maruccia, Serena; Fornia, Samanta; Lauri, Irene; Alei, Rosanna; Arcangeli, Paola; Sighinolfi, Maria Chiara; Manassero, Francesca; Andretta, Elena; Palazzetti, Anna; Bertelli, Elena; Del Popolo, Giulio; Villari, Donata

    2014-02-01

    Although several new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening and one of the most widely used questionnaires. The Italian translation of the FSFI has been used in several studies conducted in Italy, but a linguistic validation of the Italian version does not exist. The aim of this study was to perform a linguistic validation of the Italian version of the FSFI. A multicenter cross-sectional study conducted in 14 urological and gynecological clinics, uniformly distributed over Italian territory. We performed all steps necessary to determine the reliability and the test-retest reliability of the Italian version of the FSFI. The study population was a convenience sample of 409 Italian women. The reliability of the questionnaire was calculated using Cronbach's alpha, which was considered weak, moderate, or high if its value was found less than 0.6, between 0.6 and 0.8, or equal to or greater than 0.8, respectively. The test-retest reliability was assessed for all women in the sample by calculating Pearson's concordance correlation coefficient for each domain and for the total score, both at baseline and after 15 days (r range between -1.00 to +1.00, where +1.00 indicates the strongest positive association). Cronbach's alpha coefficients for total and domain score were sufficiently high, ranging from 0.92 to 0.97 for the total sample. The test-retest procedure revealed that the concordance correlation coefficient was very high both for FSFI-I total score (Pearson's P = 0.93) and for each domain (Pearson's P always >0.92). For the first time in the literature, our study has produced a validated and reliable Italian version of the FSFI questionnaire. Consequently, the Italian FSFI can be used as a reliable tool for preliminary screening for female sexual dysfunction for Italian women. © 2013 International Society for Sexual Medicine.

  2. Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.

    PubMed

    Dennison, Jessica L; Stack, Jim; Beatty, Stephen; Nolan, John M

    2013-11-01

    This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjects (79%) was suitable for analysis. Agreement between the Densitometer and Spectralis was investigated at various eccentricities using a variety of quantitative and graphical methods, including: Pearson correlation coefficient to measure degree of scatter (precision), accuracy coefficient, concordance correlation coefficient (ccc), paired t-test, scatter and Bland-Altman plots. The relationship between max MP from the Visucam and central MP from the Spectralis and Densitometer was investigated using regression methods. Agreement was strong between the Densitometer and Spectralis at all central eccentricities (e.g. at 0.25° eccentricity: accuracy = 0.97, precision = 0.90, ccc = 0.87). Regression analysis showed a very weak relationship between the Visucam and Densitometer (e.g. Visucam max on Densitometer central MP: R(2) = 0.008, p = 0.843). Regression analysis also demonstrated a weak relationship between MP measured by the Spectralis and Visucam (e.g. Visucam max on Spectralis central MP: R(2) = 0.047, p = 0.348). MP values obtained using the Heidelberg Spectralis are comparable to MP values obtained using the Densitometer. In contrast, MP values obtained using the Zeiss Visucam are not comparable with either the Densitometer or the Spectralis MP measuring devices. Taking cHFP as the current standard to which other MP measuring devices should be compared, the Spectralis is suitable for use in a clinical and research setting, whereas the Visucam is not. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Concordance of Barthel Index, ECOG-PS, and Palliative Performance Scale in the assessment of functional status in patients with advanced medical diseases.

    PubMed

    Hernández-Quiles, C; Bernabeu-Wittel, M; Pérez-Belmonte, L M; Macías-Mir, P; Camacho-González, D; Massa, B; Maiz-Jiménez, M; Ollero-Baturone, M

    2017-09-01

    Analysing most relevant clinical features and concordance between different functional scales in patients with advanced medical diseases (PAMD). Cross-sectional multicentre study that included PAMD (heart, lung, kidney, liver, and neurological diseases) in hospital settings from February 2009 to October 2010. We analysed clinical, biological and functional features in performing activities of daily living (ADL) by medians of Barthel Index (BI); additionally we assessed their performance status by medians of Eastern Cooperative Oncology Group-Performance Status (ECOG-PS) and Palliative Performance Scale (PPS) scores. We evaluated the concordance of these instruments in assessing functional impairment by κ and intraclass correlation coefficient tests. 1847 patients were included (average age 79 years, 50.1% men). Most common symptoms were dyspnoea (62.31%), asthenia (23%) and delirium (20.14%). Functional assessment showed a high prevalence of severe or total impairment in performing basic ADL by medians of used instruments (BI median=35 (IQR=70), and 52.1% of patients with severe-total impairment; ECOG-PS median=2 (IQR 30), and 44% of patients with severe-total impairment; and PPS median=50 (IQR 30), and 32% of patients with severe-total impairment). Concordance among these instruments was acceptably good ( κ indexes ranging from 0.653 to 0.745 (p<0.0001)). PAMD represent a population with severe functional impairment, which requires a multidisciplinary approach for proper management. Assessment of functional ability in this population by BI, ECOG-PS, and PPS showed good concordance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Setting health research priorities using the CHNRI method: VI. Quantitative properties of human collective opinion

    PubMed Central

    Yoshida, Sachiyo; Rudan, Igor; Cousens, Simon

    2016-01-01

    Introduction Crowdsourcing has become an increasingly important tool to address many problems – from government elections in democracies, stock market prices, to modern online tools such as TripAdvisor or Internet Movie Database (IMDB). The CHNRI method (the acronym for the Child Health and Nutrition Research Initiative) for setting health research priorities has crowdsourcing as the major component, which it uses to generate, assess and prioritize between many competing health research ideas. Methods We conducted a series of analyses using data from a group of 91 scorers to explore the quantitative properties of their collective opinion. We were interested in the stability of their collective opinion as the sample size increases from 15 to 90. From a pool of 91 scorers who took part in a previous CHNRI exercise, we used sampling with replacement to generate multiple random samples of different size. First, for each sample generated, we identified the top 20 ranked research ideas, among 205 that were proposed and scored, and calculated the concordance with the ranking generated by the 91 original scorers. Second, we used rank correlation coefficients to compare the ranks assigned to all 205 proposed research ideas when samples of different size are used. We also analysed the original pool of 91 scorers to to look for evidence of scoring variations based on scorers' characteristics. Results The sample sizes investigated ranged from 15 to 90. The concordance for the top 20 scored research ideas increased with sample sizes up to about 55 experts. At this point, the median level of concordance stabilized at 15/20 top ranked questions (75%), with the interquartile range also generally stable (14–16). There was little further increase in overlap when the sample size increased from 55 to 90. When analysing the ranking of all 205 ideas, the rank correlation coefficient increased as the sample size increased, with a median correlation of 0.95 reached at the sample size of 45 experts (median of the rank correlation coefficient = 0.95; IQR 0.94–0.96). Conclusions Our analyses suggest that the collective opinion of an expert group on a large number of research ideas, expressed through categorical variables (Yes/No/Not Sure/Don't know), stabilises relatively quickly in terms of identifying the ideas that have most support. In the exercise we found a high degree of reproducibility of the identified research priorities was achieved with as few as 45–55 experts. PMID:27350874

  5. Setting health research priorities using the CHNRI method: VI. Quantitative properties of human collective opinion.

    PubMed

    Yoshida, Sachiyo; Rudan, Igor; Cousens, Simon

    2016-06-01

    Crowdsourcing has become an increasingly important tool to address many problems - from government elections in democracies, stock market prices, to modern online tools such as TripAdvisor or Internet Movie Database (IMDB). The CHNRI method (the acronym for the Child Health and Nutrition Research Initiative) for setting health research priorities has crowdsourcing as the major component, which it uses to generate, assess and prioritize between many competing health research ideas. We conducted a series of analyses using data from a group of 91 scorers to explore the quantitative properties of their collective opinion. We were interested in the stability of their collective opinion as the sample size increases from 15 to 90. From a pool of 91 scorers who took part in a previous CHNRI exercise, we used sampling with replacement to generate multiple random samples of different size. First, for each sample generated, we identified the top 20 ranked research ideas, among 205 that were proposed and scored, and calculated the concordance with the ranking generated by the 91 original scorers. Second, we used rank correlation coefficients to compare the ranks assigned to all 205 proposed research ideas when samples of different size are used. We also analysed the original pool of 91 scorers to to look for evidence of scoring variations based on scorers' characteristics. The sample sizes investigated ranged from 15 to 90. The concordance for the top 20 scored research ideas increased with sample sizes up to about 55 experts. At this point, the median level of concordance stabilized at 15/20 top ranked questions (75%), with the interquartile range also generally stable (14-16). There was little further increase in overlap when the sample size increased from 55 to 90. When analysing the ranking of all 205 ideas, the rank correlation coefficient increased as the sample size increased, with a median correlation of 0.95 reached at the sample size of 45 experts (median of the rank correlation coefficient = 0.95; IQR 0.94-0.96). Our analyses suggest that the collective opinion of an expert group on a large number of research ideas, expressed through categorical variables (Yes/No/Not Sure/Don't know), stabilises relatively quickly in terms of identifying the ideas that have most support. In the exercise we found a high degree of reproducibility of the identified research priorities was achieved with as few as 45-55 experts.

  6. Similar predictions of etravirine sensitivity regardless of genotypic testing method used: comparison of available scoring systems.

    PubMed

    Vingerhoets, Johan; Nijs, Steven; Tambuyzer, Lotke; Hoogstoel, Annemie; Anderson, David; Picchio, Gaston

    2012-01-01

    The aims of this study were to compare various genotypic scoring systems commonly used to predict virological outcome to etravirine, and examine their concordance with etravirine phenotypic susceptibility. Six etravirine genotypic scoring systems were assessed: Tibotec 2010 (based on 20 mutations; TBT 20), Monogram, Stanford HIVdb, ANRS, Rega (based on 37, 30, 27 and 49 mutations, respectively) and virco(®)TYPE HIV-1 (predicted fold change based on genotype). Samples from treatment-experienced patients who participated in the DUET trials and with both genotypic and phenotypic data (n=403) were assessed using each scoring system. Results were retrospectively correlated with virological response in DUET. κ coefficients were calculated to estimate the degree of correlation between the different scoring systems. Correlation between the five scoring systems and the TBT 20 system was approximately 90%. Virological response by etravirine susceptibility was comparable regardless of which scoring system was utilized, with 70-74% of DUET patients determined as susceptible to etravirine by the different scoring systems achieving plasma viral load <50 HIV-1 RNA copies/ml. In samples classed as phenotypically susceptible to etravirine (fold change in 50% effective concentration ≤3), correlations with genotypic score were consistently high across scoring systems (≥70%). In general, the etravirine genotypic scoring systems produced similar results, and genotype-phenotype concordance was high. As such, phenotypic interpretations, and in their absence all genotypic scoring systems investigated, may be used to reliably predict the activity of etravirine.

  7. Basal measures of insulin sensitivity and insulin secretion and simplified glucose tolerance tests in dogs.

    PubMed

    Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M

    2010-10-01

    There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.

  8. Utility of Urinary Protein-Creatinine Ratio and Protein Content in a 24-Hour Urine Collection in Systemic Lupus Erythematosus: A Systematic Review and Meta-Analysis.

    PubMed

    Medina-Rosas, Jorge; Yap, Kristy S; Anderson, Melanie; Su, Jiandong; Touma, Zahi

    2016-09-01

    To systematically review literature on the utility of spot urinary protein-creatinine ratio (PCR) as a screening test for proteinuria and its ability to accurately measure proteinuria compared with 24-hour urine collection (24H-P) in patients with systemic lupus erythematosus (SLE). We conducted a literature search (1900-2015) for articles comparing PCR and 24H-P in SLE patients in the databases Medline, Web of Science, and Embase. Included studies and their results were critically appraised and analyzed. Thirteen studies (1,001 patients; 84.01% women) were included. Ten studies reported on Pearson's correlation (range 0.67-0.94), and 3 studies reported on Spearman's correlation (range 0.78-1.00). The meta-analysis of studies with Pearson's correlation showed a high overall correlation of 0.80 between 24H-P and PCR, yet with high heterogeneity (I(2)  = 97.2%). Correlation analysis is not sufficient to evaluate the utility of a new test against the gold standard test, and analysis on agreement is required. Seven studies reported on agreement: 3 studies analyzed concordance correlation coefficient (0.48-0.94), 3 analyzed intraclass correlation coefficient (0.66-0.95), and 1 analyzed kappa coefficient (0.58). These results confirmed that the agreement between 24H-P and PCR was inappropriate. Three studies included Bland-Altman plots, and the results also demonstrated poor agreement between both tests. The PCR has a utility as a screening test for proteinuria in SLE patients. The studies' results of 24H-P and PCR showed poor agreement between both tests, signifying that PCR should not be a substitute for the gold standard test (24H-P) to accurately measure proteinuria. © 2016, American College of Rheumatology.

  9. Reliability and validity of the Daily Cognitive-Communication and Sleep Profile: a new instrument for monitoring sleep, wakefulness and daytime function.

    PubMed

    Fung, Christina Hoi Ling; Nguyen, Michelle; Moineddin, Rahim; Colantonio, Angela; Wiseman-Hakes, Catherine

    2014-06-01

    The Daily Cognitive Communicative and Sleep Profile (DCCASP) is a seven-item instrument that captures daily subjective sleep quality, perceived mood, cognitive, and communication functions. The objective of this study was to evaluate the reliability and validity of the DCCASP. The DCCASP was self-administered daily to a convenience sample of young adults (n = 54) for two two-week blocks, interspersed with a two-week rest period. Afterwards, participants completed the Pittsburgh Sleep Quality Index (PSQI). Internal consistency and criterion validity were calculated by Cronbach's α coefficient, Concordance Correlation Coefficient (CCC), and Spearman rank (rs) correlation coefficient, respectively. Results indicated high internal consistency (Cronbach-s α = 0.864-0.938) among mean ratings of sleep quality on the DCCASP. There were significant correlations between mean ratings of sleep quality and all domains (rs=0.38-0.55, p<0.0001). Criterion validity was established between mean sleep quality ratings on the DCCASP and PSQI (rs=0.40, p<0.001). The DCCASP is a reliable and valid self-report instrument to monitor daily sleep quality and perceived mood, cognitive, and communication functions over time, amongst a normative sample of young adults. Further studies on its psychometric properties are necessary to clarify its utility in a clinical population. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Reliability of the Brazilian version of the Physical Activity Checklist Interview in children.

    PubMed

    Adami, Fernando; Cruciani, Fernanda; Douek, Michelle; Sewell, Carolina Dumit; Mariath, Aline Brandão; Hinnig, Patrícia de Fragas; Freaza, Silvia Rafaela Mascarenhas; Bergamaschi, Denise Pimentel

    2011-04-01

    To assess the reliability of the Lista de Atividades Físicas (Brazilian version of the Physical Activity Checklist Interview) in children. The study is part of a cross-cultural adaptation of the Physical Activity Checklist Interview, conducted with 83 school children aged between seven and ten years, enrolled between the 2nd and 5th grades of primary education in the city of São Paulo, Southeastern Brazil, in 2008. The questionnaire was responded by children through individual interviews. It is comprised of a list of 21 moderate to vigorous physical activities performed on the previous day, it is divided into periods (before, during and after school) and it has a section for interview assessment. This questionnaire enables the quantification of time spent in physical and sedentary activities and the total and weighed metabolic costs. Reliability was assessed by comparing two interviews conducted with a mean interval of three hours. For the interview assessment, data from the first interview and those from an external evaluator were compared. Bland-Altman's proposal, the intraclass correlation coefficient and Lin's concordance correlation coefficient were used to assess reliability. The intraclass correlation coefficient lower limits for the outcomes analyzed varied from 0.84 to 0.96. Precision and agreement varied between 0.83 and 0.97 and between 0.99 and 1, respectively. The line estimated from the pairs of values obtained in both interviews indicates high data precision. The interview item showing the poorest result was the ability to estimate time (fair in 27.7% of interviews). Interview assessment items showed intraclass correlation coefficients between 0.60 and 0.70, except for level of cooperation (0.46). The Brazilian version of the Physical Activity Checklist Interview shows high reliability to assess physical and sedentary activity on the previous day in children.

  11. Accuracy of the HumaSensplus point-of-care uric acid meter using capillary blood obtained by fingertip puncture.

    PubMed

    Fabre, Stéphanie; Clerson, Pierre; Launay, Jean-Marie; Gautier, Jean-François; Vidal-Trecan, Tiphaine; Riveline, Jean-Pierre; Platt, Adam; Abrahamsson, Anna; Miner, Jeffrey N; Hughes, Glen; Richette, Pascal; Bardin, Thomas

    2018-05-02

    The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSens plus point-of-care meter. UA levels were measured using both the HumaSens plus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSens plus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin's concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87-0.92), Lin's coefficient was 0.91 (0.88-0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 μmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 μmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine plasma results were discordant, comparison with LC-MS measurements showed that plasma measurements had better concordance: capillary UA, ICC 0.84 (95% CI 0.75-0.90), Lin's coefficient 0.84 (0.77-0.91); plasma UA, ICC 0.96 (0.94-0.98), Lin's coefficient 0.96 (0.94-0.98). UA measurements with the HumaSens plus meter were reasonably comparable with those of the laboratory assay. The meter is easy to use and may be useful in the clinic and in epidemiologic studies.

  12. Assessing the Relationship Between Sexual Concordance, Sexual Attractions, and Sexual Identity in Women.

    PubMed

    Suschinsky, Kelly D; Dawson, Samantha J; Chivers, Meredith L

    2017-01-01

    On average, there is a gender difference in sexual concordance, with men exhibiting greater agreement between genital and self-reported sexual arousal, relative to women. Much less is known about the substantial variation in women's sexual concordance; women's genital and self-reported sexual responses may correlate strongly and positively, not at all, or even strongly negatively. The within-gender variation in sexual concordance suggests that individual differences may be related to sexual concordance. We examined whether sexual concordance varies as a function of sexual orientation (based on self-reported sexual attractions and sexual identity labels) in a sample (N = 76) that included exclusively androphilic, predominantly androphilic, ambiphilic, and predominantly/exclusively gynephilic women. Participants viewed sexual and nonsexual stimuli that varied by actor gender while their vaginal vasocongestion and subjective sexual responses were measured. Women's sexual concordance varied as a function of their sexual attractions; women with any degree of gynephilia exhibited higher sexual concordance than exclusively androphilic women across a variety of sexual concordance measures, and these effects were demonstrated using correlation and multi-level modeling analyses. Only sexual concordance based on overall feelings of arousal varied by sexual identity, with heterosexual women exhibiting the lowest sexual concordance. Stimulus gender significantly influenced sexual concordance for most groups of women: Ambiphilic and predominantly/exclusively gynephilic women exhibited greater sexual concordance to female stimuli and exclusively androphilic women exhibited greater sexual concordance to male stimuli. These findings suggest that sexual orientation (particularly one's degree of gynephilia) may explain some of the within-gender variation seen in women's sexual concordance.

  13. Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer.

    PubMed

    Arratibel-Imaz, Iñaki; Calleja-González, Julio; Emparanza, Jose Ignacio; Terrados, Nicolas; Mjaanes, Jeffrey M; Ostojic, Sergej M

    2016-01-01

    The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS. The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA's 4 mmol/l and then to compare them with the direct measurement of MLSS. There were two parts to this research. Phase 1: results from 162 exertion tests chosen at random from the 1560 tests. Phase 2: sixteen athletes (n = 16) carried out different tests on five consecutive days. There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W). The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer. Dickhuth-TKM, Dmax, Dickhuth-WLa described a high concordance with the power calculated to know the MLSS.

  14. Validation of lower limb segmental volumetry with hand-held, self-positioning three-dimensional laser scanner against water displacement.

    PubMed

    Mestre, Sandrine; Veye, Florent; Perez-Martin, Antonia; Behar, Thomas; Triboulet, Jean; Berron, Nicolas; Demattei, Christophe; Quéré, Isabelle

    2014-01-01

    Measurement of limb volume is helpful for the evaluation and follow-up of edema, especially in patients with chronic venous insufficiency (CVI) or lymphedema. Water displacement (WD) is the reference method for limb volumetry but is not really suitable for clinical routine. Indirect volumetry based on circumference measurements as well as the more expansive but automatic optoelectronic techniques do not allow detailed measurement at the extremity of the limb. We used a self-positioning laser scanner with dynamic referencing for acquisition and real-time three-dimensional (3D) reconstruction of the lower limb volume in 30 patients with CVI, 30 patients with lymphedema, and 30 healthy controls. Two independent observers performed either one or two laser scans, whose results were tested for intra- and interobserver reproducibility and compared with WD volumetry by Lin's concordance correlation coefficient and Bland and Altman graphic analysis. Automatic volume calculation from 3D laser scanning data failed in one patient with major lymphedema. Lin's concordance correlation coefficient was 0.99 and 0.98, respectively, for intraobserver no. 1 and no. 2, 0.98 for interobserver reproducibility, and 0.98 and 0.96, respectively, for observer no. 1 and observer no. 2 vs WD comparison. The 3D laser scanning yielded 1.99% precision. Accuracy was 3.12% for observer no. 1 and 2.71% for observer no. 2, laser scanning values being 90 mL higher than WD, which could be attributed to the different posture during measurement. Three-dimensional laser scanning is accurate and reproducible, and appears suitable for the evaluation of limb volume in patients with CVI or lymphedema. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Air displacement plethysmography, dual-energy X-ray absorptiometry, and total body water to evaluate body composition in preschool-age children.

    PubMed

    Crook, Tina A; Armbya, Narain; Cleves, Mario A; Badger, Thomas M; Andres, Aline

    2012-12-01

    Anthropometrics and body mass index are only proxies in the evaluation of adiposity in the pediatric population. Air displacement plethysmography technology was not available for children aged 6 months to 9 years until recently. Our study was designed to test the precision of air displacement plethysmography (ADP) in measuring body fat mass in children at ages 3 to 5 years compared with a criterion method, deuterium oxide dilution (D(2)O), which estimates total body water and a commonly used methodology, dual-energy x-ray absorptiometry (DXA). A prospective, cross-sectional cohort of 66 healthy children (35 girls) was recruited in the central Arkansas region between 2007 and 2009. Weight and height were obtained using standardized procedures. Fat mass (%) was measured using ADP, DXA, and D(2)O. Concordance correlation coefficient and Bland-Altman plots were used to investigate the precision of the ADP techniques against D(2)O and DXA in children at ages 3 to 5 years. ADP concordance correlation coefficient for fat mass was weak (0.179) when compared with D(2)O. Bland-Altman plots revealed a low accuracy and large scatter of ADP fat mass (%) results (mean=-2.5, 95% CI -20.3 to 15.4) compared with D(2)O. DXA fat mass (%) results were more consistent although DXA systematically overestimated fat mass by 4% to 5% compared with D(2)O. Compared with D(2)O, ADP does not accurately assess percent fat mass in children aged 3 to 5 years. Thus, D(2)O, DXA, or quantitative nuclear magnetic resonance may be considered better options for assessing fat mass in young children. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  16. [Anthropometric model for the prediction of appendicular skeletal muscle mass in Chilean older adults].

    PubMed

    Lera, Lydia; Albala, Cecilia; Ángel, Bárbara; Sánchez, Hugo; Picrin, Yaisy; Hormazabal, María José; Quiero, Andrea

    2014-03-01

    To develop a predictive model of appendicular skeletal muscle mass (ASM) based on anthropometric measurements in elderly from Santiago, Chile. 616 community dwelling, non-disabled subjects ≥ 60 years (mean 69.9 ± 5.2 years) living in Santiago, 64.6% female, participating in ALEXANDROS study. Anthropometric measurements, handgrip strength, mobility tests and DEXA were performed. Step by step linear regression models were used to associate ASM from DEXA with anthropometric variables, age and sex. The sample was divided at random into two to obtain prediction equations for both subsamples, which were mutually validated by double cross-validation. The high correlation between the values of observed and predicted MMAE in both sub-samples and the low degree of shrinkage allowed developing the final prediction equation with the total sample. The cross-validity coefficient between prediction models from the subsamples (0.941 and 0.9409) and the shrinkage (0.004 and 0.006) were similar in both equations. The final prediction model obtained from the total sample was: ASM (kg) = 0.107(weight in kg) + 0.251( knee height in cm) + 0.197 (Calf Circumference in cm) +0.047 (dynamometry in kg) - 0.034 (Hip Circumference in cm) + 3.417 (Man) - 0.020 (age years) - 7.646 (R2 = 0.89). The mean ASM obtained by the prediction equation and the DEXA measurement were similar (16.8 ± 4.0 vs 16.9 ± 3.7) and highly concordant according Bland and Altman (95% CI: -2.6 -2.7) and Lin (concordance correlation coefficient = 0.94) methods. We obtained a low cost anthropometric equation to determine the appendicular skeletal muscle mass useful for the screening of sarcopenia in older adults. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  17. Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension.

    PubMed

    Rossi, Gian Paolo; Ceolotto, Giulio; Rossitto, Giacomo; Seccia, Teresa Maria; Maiolino, Giuseppe; Berton, Chiara; Basso, Daniela; Plebani, Mario

    2016-09-01

    The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone concentration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. We prospectively recruited 260 consecutive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: 67.3% had primary hypertension, 17.3% an aldosterone producing adenoma (APA), 11.4% idiopathic hyperaldosteronism (IHA), 2.4% renovascular hypertension (RVH), 0.8% familial hyperaldosteronism type 1 (FH-1), 0.4% apparent mineralocorticoid excess (AME), 0.4% a renin-producing tumor, and 3.9% were adrenalectomized APA patients. Bland-Altman plots and Deming regression were used to analyze results. The diagnostic accuracy (area under the curve, AUC of the ROC) of the DRC-based aldosterone-renin ratio (ARRCL) was compared with that of the PRA-based ARR (ARRRIA) using as reference the conclusive diagnosis of APA. At Bland-Altman plot, the DRC and PAC assay showed no bias as compared to the PRA and PAC assay. A tight relation was found between the DRC and the PRA values (concordance correlation coefficient=0.92, p<0.0001) and the PAC values measured with radioimmunoassay and chemiluminescence (concordance correlation coefficient=0.93, p<0.001). For APA identification the AUC of the ARRCL was higher than that of the ARRRIA [0.974 (95% CI 0.940-0.991) vs. 0.894 (95% CI 0.841-0.933), p=0.02]. This rapid automated chemiluminescent DRC/PAC assay performed better than validated PRA/PAC radioimmunoassays for the identification of APA in referred hypertensive patients.

  18. The new Asian modified CKD-EPI equation leads to more accurate GFR estimation in Chinese patients with CKD.

    PubMed

    Wang, Jinghua; Xie, Peng; Huang, Jian-Min; Qu, Yan; Zhang, Fang; Wei, Ling-Ge; Fu, Peng; Huang, Xiao-Jie

    2016-12-01

    To verify whether the new Asian modified CKD-EPI equation improved the performance of original one in determining GFR in Chinese patients with CKD. A well-designed paired cohort was set up. Measured GFR (mGFR) was the result of 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) dual plasma sample clearance method. The estimated GFR (eGFR) was the result of the CKD-EPI equation (eGFR1) and the new Asian modified CKD-EPI equation (eGFR2). The comparisons were performed to evaluate the superiority of the eGFR2 in bias, accuracy, precision, concordance correlation coefficient and the slope of regression equation and measure agreement. A total of 195 patients were enrolled and analyzed. The new Asian modified CKD-EPI equation improved the performance of the original one in bias and accuracy. However, nearly identical performance was observed in the respect of precision, concordance correlation coefficient, slope of eGFR against mGFR and 95 % limit of agreement. In the subgroup of GFR < 60 mL min -1 /1.73 m 2 , the bias of eGFR1 was less than eGFR2 but they have comparable precision and accuracy. In the subgroup of GFR > 60 mL min -1 /1.73 m 2 , eGFR2 performed better than eGFR1 in terms of bias and accuracy. The new Asian modified CKD-EPI equation can lead to more accurate GFR estimation in Chinese patients with CKD in general practice, especially in the higher GFR group.

  19. [Diagnostic concordance between seven definitions of metabolic syndrome in overweight and obese adults].

    PubMed

    Cabrera-Rode, Eduardo; Stusser, Beatriz; Cálix, Wenny; Orlandi, Neraldo; Rodríguez, Janet; Cubas-Dueñas, Ileana; Echevarría, Ragmila; Álvarez, Aimee

    2017-01-01

    The aim of this study was to determine the level of diagnostic concordance between seven definitions of metabolic syndrome (MS) in a group of overweight and obese adults. 350 subjects aged from 19 to 70 years were recruited for study from a clinic for overweight and obese subjects. The definitions of MS used were those given by the WHO (World Health Organization), EGIR (European Group for the Study of Insulin Resistance), NCEP- ATPIII (Adult Treatment Panel), AHA/NHLBI (American Heart Association), IDF (International Diabetes Federation), and JIS (Joint Interim Statement) as well as the Szabo criteria. Concordance between the definitions was calculated with the Kappa coefficient. Insulin resistance (IR) was assessed using the HOMA-IR index. According to the Szabo, WHO, EGIR, NCEP-ATPIII, AHA/NHLBI, IDF, and JIS criteria, MS frequency was 74.3%, 42.0%, 46.8%, 56.0%, 52.9%, 58.6%, and 58.6%, respectively. The concordance between the Szabo and AHA/NHLBI criteria was 0.559, while the Kappa coefficient between the Szabo criteria and the rest of the guides (NCEP-ATPIII, IDF, and JIS) was from 0.612 to 0.657, respectively. The concordance of the WHO with the EGIR was 0.602, but it was between 0.358 and 0.422 with the other guidelines. IR was distributed similarly in all guidelines. There is a considerable concordance between the NCEP-ATPIII, IDF, and JIS guidelines and the Szabo criteria. The Szabo criteria could be an option for the active surveillance of MS in populations.

  20. Laboratory-based performance evaluation of PIMA CD4+ T-lymphocyte count point-of-care by lay-counselors in Kenya.

    PubMed

    Zeh, Clement; Rose, Charles E; Inzaule, Seth; Desai, Mitesh A; Otieno, Fredrick; Humwa, Felix; Akoth, Benta; Omolo, Paul; Chen, Robert T; Kebede, Yenew; Samandari, Taraz

    2017-09-01

    CD4+ T-lymphocyte count testing at the point-of-care (POC) may improve linkage to care of persons diagnosed with HIV-1 infection, but the accuracy of POC devices when operated by lay-counselors in the era of task-shifting is unknown. We examined the accuracy of Alere's Pima™ POC device on both capillary and venous blood when performed by lay-counselors and laboratory technicians. In Phase I, we compared the perfomance of POC against FACSCalibur™ for 280 venous specimens by laboratory technicians. In Phase II we compared POC performance by lay-counselors versus laboratory technicians using 147 paired capillary and venous specimens, and compared these to FACSCalibur™. Statistical analyses included Bland-Altman analyses, concordance correlation coefficient, sensitivity, and specificity at treatment eligibility thresholds of 200, 350, and 500cells/μl. Phase I: POC sensitivity and specificity were 93.0% and 84.1% at 500cells/μl, respectively. Phase II: Good agreement was observed for venous POC results from both lay-counselors (concordance correlation coefficient (CCC)=0.873, bias -86.4cells/μl) and laboratory technicians (CCC=0.920, bias -65.7cells/μl). Capillary POC had good correlation: lay-counselors (CCC=0.902, bias -71.2cells/μl), laboratory technicians (CCC=0.918, bias -63.0cells/μl). Misclassification at the 500 cells/μl threshold for venous blood was 13.6% and 10.2% for lay-counselors and laboratory technicians and 12.2% for capillary blood in both groups. POC tended to under-classify the CD4 values with increasingly negative bias at higher CD4 values. Pima™ results were comparable to FACSCalibur™ for both venous and capillary specimens when operated by lay-counselors. POC CD4 testing has the potential to improve linkage to HIV care without burdening laboratory technicians in resource-limited settings. Published by Elsevier B.V.

  1. Validation of a patient-level medication regimen complexity index as a possible tool to identify patients for medication therapy management intervention.

    PubMed

    Hirsch, Jan D; Metz, Kelli R; Hosokawa, Patrick W; Libby, Anne M

    2014-08-01

    The Medication Regimen Complexity Index (MRCI) is a 65-item instrument that can be used to quantify medication regimen complexity at the patient level, capturing all prescribed and over-the-counter medications. Although the MRCI has been used in several studies, the narrow scope of the initial validation limits application at a population or clinical practice level. To conduct a MRCI validation pertinent to the desired clinical use to identify patients for medication therapy management interventions. An expert panel of clinical pharmacists ranked medication regimen complexity for two samples of cases: a single-disease cohort (diabetes mellitus) and a multiple-disease cohort (diabetes mellitus, hypertension, human immunodeficiency virus infection, geriatric depression). Cases for expert panel review were selected from 400 ambulatory clinic patients, and each case description included data that were available via claims or electronic medical records (EMRs). Construct validity was assessed using patient-level MRCI scores, medication count, and additional patient data. Concordance was evaluated using weighted κ agreement statistic, and correlations were determined using Spearman rank-order correlation coefficient (ρ) or Kendall τ. Moderate to good concordance between patient-level MRCI scores and expert medication regimen complexity ranking was observed (claims data, consensus ranking: single-disease cohort 0.55, multiple disease cohort 0.63). In contrast, only fair to moderate concordance was observed for medication count (single-disease cohort 0.33, multiple-disease cohort 0.48). Adding more-detailed administration directions from EMR data did not improve concordance. MRCI convergent validity was supported by strong correlations with medication count (all cohorts 0.90) and moderate correlations with morbidity measures (e.g., all cohorts; number of comorbidities 0.46, Chronic Disease Score 0.46). Nonsignificant correlation of MRCI scores with age and gender (all cohorts 0.08 and 0.06, respectively) supported MRCI divergent validity. This study used cross-sectional, retrospective patient data for a small number of patients and clinical pharmacists from only two universities; therefore, results may have limited generalizability. The patient-level MRCI is a valid tool for assessing medication regimen complexity that can be applied by using data commonly found in claims and EMR databases and could be useful to identify patients who may benefit from medication therapy management. © 2014 The Authors Pharmacotherapy published by Wiley Periodicals, Inc. on behalf of Pharmacotherapy Publications, Inc.

  2. Heritability and intrafamilial aggregation of arterial characteristics.

    PubMed

    Seidlerová, Jitka; Bochud, Murielle; Staessen, Jan A; Cwynar, Marcin; Dolejsová, Milena; Kuznetsova, Tatiana; Nawrot, Tim; Olszanecka, Agnieszka; Stolarz, Katarzyna; Thijs, Lutgarde; Wojciechowska, Wiktoria; Struijker-Boudier, Harry A; Kawecka-Jaszcz, Kalina; Elston, Robert C; Fagard, Robert; Filipovský, Jan

    2008-04-01

    We investigated the heritability and familial aggregation of various indexes of arterial stiffness and wave reflection and we partitioned the phenotypic correlation between these traits into shared genetic and environmental components. Using a family-based population sample, we recruited 204 parents (mean age, 51.7 years) and 290 offspring (29.4 years) from the population in Cracow, Poland (62 families), Hechtel-Eksel, Belgium (36), and Pilsen, the Czech Republic (50). We measured peripheral pulse pressure (PPp) sphygmomanometrically at the brachial artery; central pulse pressure (PPc), the peripheral augmentation indexes (PAIxs) and central augmentation indexes (CAIxs) by applanation tonometry at the radial artery; and aortic pulse wave velocity (PWV) by tonometry or ultrasound. In multivariate-adjusted analyses, we used the ASSOC and PROC GENMOD procedures as implemented in SAGE and SAS, respectively. We found significant heritability for PAIx, CAIx, PPc and mean arterial pressure ranging from 0.37 to 0.41; P < or = 0.0001. The method of intrafamilial concordance confirmed these results; intrafamilial correlation coefficients were significant for all arterial indexes (r > or = 0.12; P < or = 0.02) with the exception of PPc (r = -0.007; P = 0.90) in parent-offspring pairs. The sib-sib correlations were also significant for CAIx (r = 0.22; P = 0.001). The genetic correlation between PWV and the other arterial indexes were significant (rhoG > or = 0.29; P < 0.0001). The corresponding environmental correlations were only significantly positive for PPp (rhoE = 0.10, P = 0.03). The observation of significant intrafamilial concordance and heritability of various indexes of arterial stiffness as well as the genetic correlations among arterial phenotypes strongly support the search for shared genetic determinants underlying these traits.

  3. Tracking Steps on Apple Watch at Different Walking Speeds.

    PubMed

    Veerabhadrappa, Praveen; Moran, Matthew Duffy; Renninger, Mitchell D; Rhudy, Matthew B; Dreisbach, Scott B; Gift, Kristin M

    2018-04-09

    QUESTION: How accurate are the step counts obtained from Apple Watch? In this validation study, video steps vs. Apple Watch steps (mean ± SD) were 2965 ± 144 vs. 2964 ± 145 steps; P < 0.001. Lin's concordance correlation coefficient showed a strong correlation (r = 0.96; P < 0.001) between the two measurements. There was a total error of 0.034% (1.07 steps) for the Apple Watch steps when compared with the manual counts obtained from video recordings. Our study is one of the initial studies to objectively validate the accuracy of the step counts obtained from Apple watch at different walking speeds. Apple Watch tested to be an extremely accurate device for measuring daily step counts for adults.

  4. Judging in Rhythmic Gymnastics at Different Levels of Performance.

    PubMed

    Leandro, Catarina; Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta

    2017-12-01

    This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach's alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges' difficulty scores, the Kendall's coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach's alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level.

  5. Judging in Rhythmic Gymnastics at Different Levels of Performance

    PubMed Central

    Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta

    2017-01-01

    Abstract This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach’s alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges’ difficulty scores, the Kendall’s coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach’s alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level. PMID:29339996

  6. Concordance of patient and caregiver reports in evaluating quality of life in patients with malignant gliomas and an assessment of caregiver burden

    PubMed Central

    Jacobs, Daniel I.; Kumthekar, Priya; Stell, Becky V.; Grimm, Sean A.; Rademaker, Alfred W.; Rice, Laurie; Chandler, James P.; Muro, Kenji; Marymont, MaryAnne; Helenowski, Irene B.; Wagner, Lynne I.; Raizer, Jeffrey J.

    2014-01-01

    Background Given the neurocognitive impairment experienced by many patients with malignant gliomas, caregiver reports can be critical in assessing the quality of life (QOL) of these patients. In this study, we explored whether assessment of patient QOL by the primary caregiver shows concordance with the patient's self-reported QOL, and we quantified the burden faced by caregivers. Methods QOL of 45 patients was evaluated by both the patient and primary caregiver on 3 or more separate occasions using the Functional Assessment of Cancer Therapy-Brain (FACT-Br) instrument, and concordance between the 2 reports was evaluated. Caregiver burden was measured using the Caregiver Quality of Life Index-Cancer (CQOL-C) instrument. Results Overall, good concordance was observed between the patient and caregiver FACT-Br reports (intraclass correlation coefficient = 0.74). Patient-reported FACT-Br scores were 4.75 (95% CI, 1.44–8.05) points higher than paired caregiver reports on the 200-point scale (P = .008); however, this difference did not achieve clinical significance. Caregiver burden, as measured by the CQOL-C, was significantly greater among caregivers in this study than those previously reported for caregivers of patients with lung, breast, or prostate cancer (P < .001). Conclusions Despite minor discrepancies in caregiver assessments of patient QOL relative to patient self-reports, our results suggest that the caregiver assessments can serve as adequate proxies for patient reports. Our results also illustrate the particularly heavy burden faced by caregivers of patients with malignant glioma. Further research into both of these areas is warranted. PMID:26034616

  7. Smartphone photography utilized to measure wrist range of motion.

    PubMed

    Wagner, Eric R; Conti Mica, Megan; Shin, Alexander Y

    2018-02-01

    The purpose was to determine if smartphone photography is a reliable tool in measuring wrist movement. Smartphones were used to take digital photos of both wrists in 32 normal participants (64 wrists) at extremes of wrist motion. The smartphone measurements were compared with clinical goniometry measurements. There was a very high correlation between the clinical goniometry and smartphone measurements, as the concordance coefficients were high for radial deviation, ulnar deviation, wrist extension and wrist flexion. The Pearson coefficients also demonstrated the high precision of the smartphone measurements. The Bland-Altman plots demonstrated 29-31 of 32 smartphone measurements were within the 95% confidence interval of the clinical measurements for all positions of the wrists. There was high reliability between the photography taken by the volunteer and researcher, as well as high inter-observer reliability. Smartphone digital photography is a reliable and accurate tool for measuring wrist range of motion. II.

  8. Assessment methods for aspirin-mediated platelet antiaggregation in type 2 diabetic patients: degree of correlation between 2 point-of-care methods.

    PubMed

    Cubero Gómez, Jose M; Navarro Puerto, María A; Acosta Martínez, Juan; De Mier Barragán, María I; Pérez Santigosa, Pastor L; Sánchez Burguillos, Francisco; Molano Casimiro, Francisco; Pastor Torres, Luis

    2014-07-01

    Impaired response to antiplatelet therapy in diabetic patients results in a higher incidence of drug-eluting stent thrombosis. This study determined the prevalence of high on-aspirin (AS) platelet reactivity in type 2 diabetic patients treated with percutaneous coronary intervention (PCI) using the VerifyNow Aspirin Assay (VN) and platelet function analyzer PFA-100 (PFA-100) and analyzed the correlation between both methods. Type 2 diabetic patients (100) with non-ST-elevation acute coronary syndrome who underwent PCI and Xience V drug-eluting stent implantation were included in this study. After PCI, platelet antiaggregation mediated by acetylsalicylic acid was assessed by VN and PFA-100. The degree of correlation and concordance was then determined. When assayed with VN, 7% of the patients were nonresponders to aspirin (aspirin reaction units >550), and when assayed with PFA-10, 41% were nonresponders (closure time <193 seconds). Of the patients, 4% were nonresponders to aspirin according to VN but were sensitive to aspirin according to PFA-100, and 38% were sensitive to aspirin according to VN and nonresponders according to PFA-100. Overall, 55% of the patients were aspirin-sensitive in both methods. The Spearman's coefficient between VN and PFA-100 results was r = 0.09 (P = 0.35). The kappa index value was 0.0062 (P = 0.91). There is no concordance or correlation between the VN and PFA-100 results. Therefore, the use of these analyses should be restricted to clinical research, which limits its application in clinical practice.

  9. A quality control study on cytotechnologist-cytopathologist concordance and its relationship to the number of dots on the slide.

    PubMed

    Bongiovanni, Massimo; De Saussure, Barbara; Kumar, Neeta; Pache, Jean-Claude; Cibas, Edmund S

    2009-01-01

    To study cytotechnologist (CT)-cytopathologist (CP) concordance for evaluating individual CTs' performance and for quality assurance and educational feedback. The interpretations of individual CTs were compared with the final interpretations (according to the 2001 Bethesda System) of the CP. Concordance percentages and kappa values were calculated for each CT and correlated with the numbers of dots on each slide, years of experience and percentage of work hours devoted to cytology. A total of 10,453 Pap tests were screened by 9 CTs during one year, out of which 993 (9.5%) were referred to one CP for a final interpretation. Mean concordance between the aggregate CT interpretations and those of the CP was 65.5%. Five CTs had good concordance, 3 had moderately good concordance, and one had surprisingly poor concordance that contrasted with good subjective impressions. No correlation was found between concordance and the average number of dots per slide, screening experience in cervicovaginal cytology or percentage of work hours devoted to cytology. Monitoring CT-CP concordance rates can unveil performance issues not detected by subjective impressions. An excessive number of dots per slide may not reflect poor diagnostic precision so much as a lack of confidence in interpretation.

  10. Saving time and money: a validation of the self ratings on the prospective NIMH Life-Chart Method (NIMH-LCM).

    PubMed

    Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars

    2014-05-07

    Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p < .001), whilst the correlation of ratings for mania with YMRS compared to LC-self were slightly less robust (Pearson coefficient r = .491; p = .001). These results were confirmed by good correlations between the CGI-BP IA (mania), IB (depression) and IC (overall mood state) and the LC-self ratings (Pearson coefficient r = .488, r = .721 and r = .65, respectively; all p < .001). The LC-self shows a significant correlation and good concordance with standard cross sectional affective rating scales, suggesting that the LC-self is a valid and time and money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.

  11. Combined molecular modelling and 3D-QSAR study for understanding the inhibition of NQO1 by heterocyclic quinone derivatives.

    PubMed

    López-Lira, Claudia; Alzate-Morales, Jans H; Paulino, Margot; Mella-Raipán, Jaime; Salas, Cristian O; Tapia, Ricardo A; Soto-Delgado, Jorge

    2018-01-01

    A combination of three-dimensional quantitative structure-activity relationship (3D-QSAR), and molecular modelling methods were used to understand the potent inhibitory NAD(P)H:quinone oxidoreductase 1 (NQO1) activity of a set of 52 heterocyclic quinones. Molecular docking results indicated that some favourable interactions of key amino acid residues at the binding site of NQO1 with these quinones would be responsible for an improvement of the NQO1 activity of these compounds. The main interactions involved are hydrogen bond of the amino group of residue Tyr128, π-stacking interactions with Phe106 and Phe178, and electrostatic interactions with flavin adenine dinucleotide (FADH) cofactor. Three models were prepared by 3D-QSAR analysis. The models derived from Model I and Model III, shown leave-one-out cross-validation correlation coefficients (q 2 LOO ) of .75 and .73 as well as conventional correlation coefficients (R 2 ) of .93 and .95, respectively. In addition, the external predictive abilities of these models were evaluated using a test set, producing the predicted correlation coefficients (r 2 pred ) of .76 and .74, respectively. The good concordance between the docking results and 3D-QSAR contour maps provides helpful information about a rational modification of new molecules based in quinone scaffold, in order to design more potent NQO1 inhibitors, which would exhibit highly potent antitumor activity. © 2017 John Wiley & Sons A/S.

  12. Incorporation of diffusion-weighted magnetic resonance imaging data into a simple mathematical model of tumor growth

    NASA Astrophysics Data System (ADS)

    Atuegwu, N. C.; Colvin, D. C.; Loveless, M. E.; Xu, L.; Gore, J. C.; Yankeelov, T. E.

    2012-01-01

    We build on previous work to show how serial diffusion-weighted MRI (DW-MRI) data can be used to estimate proliferation rates in a rat model of brain cancer. Thirteen rats were inoculated intracranially with 9L tumor cells; eight rats were treated with the chemotherapeutic drug 1,3-bis(2-chloroethyl)-1-nitrosourea and five rats were untreated controls. All animals underwent DW-MRI immediately before, one day and three days after treatment. Values of the apparent diffusion coefficient (ADC) were calculated from the DW-MRI data and then used to estimate the number of cells in each voxel and also for whole tumor regions of interest. The data from the first two imaging time points were then used to estimate the proliferation rate of each tumor. The proliferation rates were used to predict the number of tumor cells at day three, and this was correlated with the corresponding experimental data. The voxel-by-voxel analysis yielded Pearson's correlation coefficients ranging from -0.06 to 0.65, whereas the region of interest analysis provided Pearson's and concordance correlation coefficients of 0.88 and 0.80, respectively. Additionally, the ratio of positive to negative proliferation values was used to separate the treated and control animals (p <0.05) at an earlier point than the mean ADC values. These results further illustrate how quantitative measurements of tumor state obtained non-invasively by imaging can be incorporated into mathematical models that predict tumor growth.

  13. Validation of an adapted arabic version of fibromyalgia syndrome impact questionnaire.

    PubMed

    El-Naby, Mai Abd; Hefny, Mohamed Ahmed; Fahim, Ayman Ekram; Awadalla, Magdy Ahmed

    2013-10-01

    Fibromyalgia (FM) is the most common chronic pain syndrome encountered in medical practice, affecting females more than males, and the estimated prevalence of FM in Egypt is 1.3 %. The aim was to translate and adapt the Fibromyalgia Impact Questionnaire (FIQ) into Arabic and assess reliability and validity. The Arabic version of Fibromyalgia Impact Questionnaire (FIQ-A) was adapted following the forward/backward translation approach. Fifty-one female patients with FM were studied to assess psychometric properties of the FIQ-A. Reliability was analyzed by the correlation coefficient between test and retest. Internal consistency was checked by the Cronbach's alpha coefficient. Construct validity was assessed comparing FIQ-A with Health Assessment Questionnaire (HAQ), Health Assessment Questionnaire of Fibromyalgia (FHAQ), The Medical Outcome Survey Short-Form-36 (SF-36), and the Total Visual Analog Scale (TVAS) for FM symptom, and feasibility was assessed by the time taken in completing the FIQ-A and the proportion of patients completed the questionnaire. Patients studied were 33.2 ± 9.8 years old. Translation was concordant. Adaptation affected 4 sub-items of physical function. Test-retest correlation coefficient was 0.89 for total FIQ-A and Cronbach's alpha was 0.76. Excellent to good statistically significant correlations (p < 0.05) were found between the FIQ-A items and HAQ, FHAQ, and SF-36. The FIQ-A is a reliable, valid for measuring health status and physical function in Arabic-speaking FM patients.

  14. Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging.

    PubMed

    Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael

    2016-02-25

    Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.

  15. Objective measurements for grading the nasal esthetics on Basal view in individuals with secondary cleft nasal deformity.

    PubMed

    He, Xing; Li, Hua; Shao, Yan; Shi, Bing

    2015-01-01

    The purpose of this study is to ascertain objective nasal measurements from the basal view that are predictive of nasal esthetics in individuals with secondary cleft nasal deformity. Thirty-three patients who had undergone unilateral cleft lip repair were retrospectively reviewed in this study. The degree of nasal deformity was subjectively ranked by seven surgeons using standardized basal-view measurements. Nine physical objective parameters including angles and ratios were measured. Correlations and regressions between these objective and subjective measurements were then analyzed. There was high concordance in subjective measurements by different surgeons (Kendall's harmonious coefficient = W = .825, P = .006). The strongest predictive factors for nasal aesthetics were the ratio of length of nasal alar (r = .370, P = .034) and the degree of deviation of the columnar axis (r = .451, P = .008). The columellar angle had a more powerful effect in rating nasal esthetics. There was reliable concordance in subjective ranking of nasal esthetics by surgeons. Measurement of the columnar angle may serve as an independent, objective predictor of esthetics of the nose.

  16. Concordance correlation for model performance assessment: An example with reference evapotranspiration

    USDA-ARS?s Scientific Manuscript database

    Procedures for assessing model performance in agronomy are often arbitrary and not always helpful. An omnibus analysis statistic, concordance correlation, is widely known and used in many other sciences. An illustrative example is presented here. The analysis assumes the exact relationship “observat...

  17. Skin elasticity as a measure of radiation fibrosis: is it reproducible and does it correlate with patient and physician-reported measures?

    PubMed

    Nguyen, Nhu-Tram A; Roberge, David; Freeman, Carolyn R; Wong, Cindy; Hines, Jerod; Turcotte, Robert E

    2014-10-01

    Current means of measuring RT-induced fibrosis are subjective. We evaluated the DermaLab suction cup system to measure objectively skin deflection as a surrogate for fibrosis. Sixty-nine patients with E-STS were treated with limb-sparing surgery and 50-66 Grays (Gy) of RT. Using a "scleroderma" DermaLab Suction Cup, the skin stiffness was measured by two clinicians. The National Cancer Institute Common Terminology Criteria for Adverse Events (NCI-CTCAE) scale, the Musculoskeletal Tumor Rating Scale (MSTS) and Toronto Extremity Salvage Score (TESS) questionnaires were completed for each patient. Levels of agreement between measurers were estimated using the Kappa (k) coefficient and the concordance correlation coefficient (CCC). All sixty-nine patients were included. The level of agreement between measurers for NCI-CTCAE grading was moderate (range k = 0.41-0.59). The CCC for the elasticity measurements were higher, with CCC = 0.82 for fibrotic skin and CCC 5 0.84 for normal skin. The elasticity measurements were significantly higher when MSTS scores were <30 and or TESS scores were <90. Suction Cup measurement of skin elasticity is more reproducible than CTCAE grading and shows promise in generating reproducible measurements for radiation-induced skin fibrosis. Furthermore, it correlates well with the MSTS and TESS.

  18. International inter-rater agreement in scoring acne severity utilizing cloud-based image sharing of mobile phone photographs.

    PubMed

    Foolad, Negar; Ornelas, Jennifer N; Clark, Ashley K; Ali, Ifrah; Sharon, Victoria R; Al Mubarak, Luluah; Lopez, Andrés; Alikhan, Ali; Al Dabagh, Bishr; Firooz, Alireza; Awasthi, Smita; Liu, Yu; Li, Chin-Shang; Sivamani, Raja K

    2017-09-01

    Cloud-based image sharing technology allows facilitated sharing of images. Cloud-based image sharing technology has not been well-studied for acne assessments or treatment preferences, among international evaluators. We evaluated inter-rater variability of acne grading and treatment recommendations among an international group of dermatologists that assessed photographs. This is a prospective, single visit photographic study to assess inter-rater agreement of acne photographs shared through an integrated mobile device, cloud-based, and HIPAA-compliant platform. Inter-rater agreements for global acne assessment and acne lesion counts were evaluated by the Kendall's coefficient of concordance while correlations between treatment recommendations and acne severity were calculated by Spearman's rank correlation coefficient. There was good agreement for the evaluation of inflammatory lesions (KCC = 0.62, P < 0.0001), noninflammatory lesions (KCC = 0.62, P < 0.0001), and the global acne grading system score (KCC = 0.69, P < 0.0001). Topical retinoid, oral antibiotic, and isotretinoin treatment preferences correlated with photographic based acne severity. Our study supports the use of mobile phone based photography and cloud-based image sharing for acne assessment. Cloud-based sharing may facilitate acne care and research among international collaborators. © 2017 The International Society of Dermatology.

  19. Validation of a Persian version of the Fibromyalgia Impact Questionnaire (FIQ-P).

    PubMed

    Bidari, Ali; Hassanzadeh, Morteza; Mohabat, Mohamad-Farzam; Talachian, Elham; Khoei, Effat Merghati

    2014-02-01

    The aim of this study is to translate, adapt, and validate a Persian version of the Fibromyalgia (FM) Impact Questionnaire (FIQ-P). The FIQ-P was adapted following the translation and back-translation approach; then, it was administered to thirty females with FM. Participants also completed two other validated questionnaires, the Medical Outcome Survey Short Form-36 (SF-36) and the Beck Depression Inventory (BDI). Internal consistency within the FIQ-P items and its test-retest reliability were assessed with Cronbach's alpha and Spearman's correlation coefficient, respectively. Construct validity was analyzed by Spearman's r when correlating the FIQ-P to other questionnaires. The translated version was concordant. Adaptation affected two sub-items of physical function. Participants' mean age ± standard deviation was 40.4 ± 9.0 years. Internal consistency proved good with α = 0.80. Test-retest coefficient ranged from 0.50 for the item "work days missed" to 0.79 for all FIQ-P items. Fair and statistically significant (P < 0.01) correlations were found between the FIQ-P items and two other questionnaires, SF-36 (r = -0.57) and BDI (r = 0.53). We concluded that the FIQ-P is a valid and reliable instrument for measuring health status of Persian-speaking FM patients.

  20. [Abdominal ultrasound and magnetic resonance imaging: a comparative study on the non-alcoholic fatty liver disease diagnosis in morbidly obese patients].

    PubMed

    Chaves, Gabriela Villaça; Pereira, Sílvia Elaine; Saboya, Carlos José; Cortes, Caroline; Ramalho, Rejane

    2009-01-01

    To evaluate the concordance between abdominal ultrasound and an MRI (Magnetic Resonance Imaging) in the diagnosis of non-alcoholic fatty liver disease (NAFLD), and concordance of these two methods with the histopathological exam. The population studied was comprised of 145 patients with morbid obesity (BMI > or = 40 Kg/m(2)), of both genders. NAFLD diagnosis was performed by MRI and Ultrasound. Liver biopsy was performed in a sub-sample (n=40). To evaluate the concordance of these two methods, the kappa coefficient was used. Concordance between both methods (MRI and Ultrasound) was poor and not significant (Kappa adjusted= 0.27; CI 95%= 0.07-0.39.) Nevertheless a slight concordance was found between diagnosis of NAFLD by ultrasound and the hepatic biopsy, with 83.,3% of concordant results and Kappa adjusted= 0.67.Results of an MRI and the histopathological exam were compared and results showed 53.6% of concordant results and kappa adjusted= 0.07. The concordance found in the diagnosis performed using the ultrasound method and the hepatic biopsy, shows a need to implement and perform more research on the use of ultrasound to validate and reconsider these methods. This would minimize the need to perform biopsies to detect and diagnose such disease.

  1. Comparison of Four PD-L1 Immunohistochemical Assays in Lung Cancer.

    PubMed

    Hendry, Shona; Byrne, David J; Wright, Gavin M; Young, Richard J; Sturrock, Sue; Cooper, Wendy A; Fox, Stephen B

    2018-03-01

    Four different programmed death ligand 1 immunohistochemical assays are approved or in development as companion or complementary diagnostics to different immunotherapeutic agents in lung carcinoma. We sought to determine whether these assays are technically equivalent and whether one antibody can be used on an alternate staining platform. Serial sections of tissue microarrays constructed from 368 cases of resected lung cancer were stained for 22C3 and 28-8 on the Dako Link 48 platform (Dako, Carpinteria, Ca) and for SP142 and SP263 on the Ventana Benchmark Ultra platform (Ventana Medical Systems, Tucson, AZ) strictly as per product insert. A protocol was developed to use the 22C3 antibody on the Ventana Benchmark Ultra platform. Differences in mean tumor cell and immune cell staining were observed between the four assays (p < 0.001). Differences between 22C3 and 28-8 were not statistically significant. Concordance of tumor cell scores was good (intraclass correlation coefficient [ICC] = 0.674), particularly when SP142 was excluded as an outlier (ICC = 0.755). The highest concordance was seen between 22C3 and 28-8 (ICC = 0.812). Concordance was poor for immune cell staining (ICC = 0.212). When dichotomized according to clinically relevant cutoffs, pairwise comparisons showed poor to moderate concordance (κ = 0.196-0.578), with positive percent agreement ranging from 15.1% to 90.0%. The 22C3 antibody performed comparably on the Dako Link 48 platform and the alternate Ventana Benchmark Ultra platform (ICC = 0.921, κ = 0.897). Concordance between the four programmed death ligand 1 immunohistochemical assays when performed and scored as intended show that apart from 28-8 and 22C3, they cannot be used interchangeably in clinical practice. A protocol was successfully developed to use 22C3 on an alternate platform, which may help to overcome some barriers to implementation. Copyright © 2017 International Association for the Study of Lung Cancer. All rights reserved.

  2. High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance.

    PubMed

    Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H

    2011-12-01

    We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Poor-to-moderate agreement between self and proxy interviews of mobile phone use.

    PubMed

    Hutter, Hans-Peter; Ehrenhöfer, Lisa; Freuis, Edith; Hartl, Patrik; Kundi, Michael

    2012-10-01

    In epidemiological studies, cases cannot always be interviewed due to them being too ill or already deceased. Under these circumstances, proxy interviews are often conducted; however, the veridicality of information about mobile phone use gained by proxy interviews has been doubted. The issue is undecided due to the lack of empirical data. We conducted a study of 119 heterosexual couples. Both partners answered two questionnaires about mobile phone use, one about their own use and one about their partner's use. Overall agreement assessed using Cohen's kappa, Passing and Bablok regression, and concordance coefficients between self and proxy data was poor to moderate (e.g., concordance coefficients of 0.55 for duration of use). The only item with good agreement was whether or not a prepaid phone was used (Cohen's kappa 0.78 and 0.63 for male and female estimates, respectively), and to a lesser degree, the onset of mobile phone use (concordance coefficients of 0.66 and 0.61). Poorest agreement was obtained for the side of the head the mobile phone was held during calls (kappa coefficients of 0.20 and 0.24 for female and male estimates, respectively). We conclude that the assessment of mobile phone use by proxy data cannot be relied on except for information about onset of mobile phone use, use of prepaid or contract phones, and, to a lesser degree, duration of daily use. Agreement concerning the important information about side of the head the mobile phone is held during calls was poorest and only slightly better than chance. Copyright © 2012 Wiley Periodicals, Inc.

  4. Comparison and Agreement Between the Richmond Agitation-Sedation Scale and the Riker Sedation-Agitation Scale in Evaluating Patients’ Eligibility for Delirium Assessment in the ICU

    PubMed Central

    Guzman, Oscar; Campbell, Noll L.; Walroth, Todd; Tricker, Jason L.; Hui, Siu L.; Perkins, Anthony; Zawahiri, Mohammed; Buckley, John D.; Farber, Mark O.; Ely, E. Wesley; Boustani, Malaz A.

    2012-01-01

    Background: Delirium evaluation in patients in the ICU requires the use of an arousal/sedation assessment tool prior to assessing consciousness. The Richmond Agitation-Sedation Scale (RASS) and the Riker Sedation-Agitation Scale (SAS) are well-validated arousal/sedation tools. We sought to assess the concordance of RASS and SAS assessments in determining eligibility of patients in the ICU for delirium screening using the confusion assessment method for the ICU (CAM-ICU). Methods: We performed a prospective cohort study in the adult medical, surgical, and progressive (step-down) ICUs of a tertiary care, university-affiliated, urban hospital in Indianapolis, Indiana. The cohort included 975 admissions to the ICU between January and October 2009. Results: The outcome measures of interest were the correlation and agreement between RASS and SAS measurements. In 2,469 RASS and SAS paired screens, the rank correlation using the Spearman correlation coefficient was 0.91, and the agreement between the two screening tools for assessing CAM-ICU eligibility as estimated by the κ coefficient was 0.93. Analysis showed that 70.1% of screens were eligible for CAM-ICU assessment using RASS (7.1% sedated [RASS −3 to −1]; 62.6% calm [0]; and 0.4% restless, agitated [+1 to +3]), compared with 72.1% using SAS (5% sedated [SAS 3]; 66.5% calm [4]; and 0.6% anxious, agitated [5, 6]). In the mechanically ventilated subgroup, RASS identified 19.1% CAM-ICU eligible patients compared with 24.6% by SAS. The correlation coefficient in this subgroup was 0.70 and the agreement was 0.81. Conclusion: Both SAS and RASS led to similar rates of delirium assessment using the CAM-ICU. PMID:22539644

  5. Weight status of indigenous youth in Oaxaca, southern Mexico: concordance of IOTF and WHO criteria.

    PubMed

    Malina, Robert M; Peйa Reyes, Maria Eugenia; Chávez, Guillermo Bali; Little, Bertis B

    2013-01-01

    To compare the prevalence of thinness, overweight and obesity with IOTF and WHO criteria among indigenous school youth from the state of Oaxaca, southern Mexico. The sample included 11 454 indigenous youth (6216 boys, 5238 girls) 6-14 years of age. Heights and weights were measured in 2007 by trained staff. BMIs were calculated and classified as severely thin, moderately thin, normal, overweight or obese using age- and sex-specific IOTF and WHO cut-offs. Prevalence, percentage agreement between classifications, Spearman rank order correlations and Kappa coefficients were calculated. Prevalence of overweight and obesity was higher with WHO than IOTF criteria, while prevalence of severe and moderate thinness did not appreciably differ between criteria. Weight status with the two criteria was discordant in 839 boys (13.5%) and 383 girls (7.3%) and more often for overweight and obesity than thinness. Percentage agreement, correlations and Kappa coefficients were moderate-to-high and were higher in girls than boys. Prevalence of overweight and obesity among indigenous youth in Oaxaca was higher with WHO than IOTF criteria, whereas prevalence of severe and moderate thinness was similar. Differences in estimates for overweight and obesity have implications for surveillance.

  6. Reliability and construct validity of the Spanish version of the 6-item CTS symptoms scale for outcomes assessment in carpal tunnel syndrome.

    PubMed

    Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam

    2016-03-03

    The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.

  7. Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network.

    PubMed

    Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola

    2018-01-01

    Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.

  8. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise.

    PubMed

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall's coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index.

  9. Magnetic resonance elastography of the pancreas: Measurement reproducibility and relationship with age.

    PubMed

    Kolipaka, Arunark; Schroeder, Samuel; Mo, Xiaokui; Shah, Zarine; Hart, Phil A; Conwell, Darwin L

    2017-10-01

    To determine magnetic resonance elastography (MRE)-derived stiffness of pancreas in healthy volunteers with emphasis on: 1) short term and midterm repeatability; and 2) variance as a function of age. Pancreatic MRE was performed on 22 healthy volunteers (age range:20-64years) in a 3T-scanner. For evaluation of reproducibility of stiffness estimates, the scans were repeated per volunteer on the same day (short term) and one month apart (midterm). MRE wave images were analyzed using 3D inversion to estimate the stiffness of overall pancreas and different anatomic regions (i.e., head, neck, body, and tail). Concordance and Spearman correlation tests were performed to determine reproducibility of stiffness measurements and relationship to age. A strong concordance correlation (ρ c =0.99; p-value<0.001) was found between short term and midterm repeatability pancreatic stiffness measurements. Additionally, the pancreatic stiffness significantly increased with age with good Spearman correlation coefficient (all ρ>0.81; p<0.001). The older age group (>45yrs) had significantly higher stiffness compared to the younger group (≤45yrs) (p<0.001). No significant difference (p>0.05) in stiffness measurements was observed between different anatomical regions of pancreas, except neck stiffness was slightly lower (p<0.012) compared to head and overall pancreas at month 1. MRE-derived pancreatic stiffness measurements are highly reproducible in the short and midterm and increase linearly with age in healthy volunteers. Further studies are needed to examine these effects in patients with various pancreatic diseases to understand potential clinical applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The Outpatient Experience Questionnaire of comprehensive public hospital in China: development, validity and reliability.

    PubMed

    Hu, Yinhuan; Zhang, Zixia; Xie, Jinzhu; Wang, Guanping

    2017-02-01

    The objective of this study is to describe the development of the Outpatient Experience Questionnaire (OPEQ) and to assess the validity and reliability of the scale. Literature review, patient interviews, Delphi method and Cross-sectional validation survey. Six comprehensive public hospitals in China. The survey was carried out on a sample of 600 outpatients. Acceptability of the questionnaire was assessed according to the overall response rate, item non-response rate and the average completion time. Correlation coefficients and confirmatory factor analysis were used to test construct validity. Delphi method was used to assess the content validity of the questionnaire. Cronbach's coefficient alpha and split-half reliability coefficient were used to estimate the internal reliability of the questionnaire. The overall response rate was 97.2% and the item non-response rate ranged from 0% to 0.3%. The mean completion time was 6 min. The Spearman correlations of item-total score ranged from 0.466 to 0.765. The results of confirmatory factor analysis showed that all items had factor loadings above 0.40 and the dimension intercorrelation ranged from 0.449 to 0.773, the goodness of fit of the questionnaire was reasonable. The overall authority grade of expert consultation was 0.80 and Kendall's coefficient of concordance W was 0.186. The Cronbach's coefficients alpha of six dimensions ranged from 0.708 to 0.895, the split-half reliability coefficient (Spearman-Brown coefficient) was 0.969. The OPEQ is a promising instrument covering the most important aspects which influence outpatient experiences of comprehensive public hospital in China. It has good evidence for acceptability, validity and reliability. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  11. Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules.

    PubMed

    Milanese, Gianluca; Eberhard, Matthias; Martini, Katharina; Vittoria De Martini, Ilaria; Frauenfelder, Thomas

    2018-04-01

    To evaluate whether vessel-suppressed computed tomography (VSCT) can be reliably used for semi-automated volumetric measurements of solid pulmonary nodules, as compared to standard CT (SCT) MATERIAL AND METHODS: Ninety-three SCT were elaborated by dedicated software (ClearRead CT, Riverain Technologies, Miamisburg, OH, USA), that allows subtracting vessels from lung parenchyma. Semi-automated volumetric measurements of 65 solid nodules were compared between SCT and VSCT. The measurements were repeated by two readers. For each solid nodule, volume measured on SCT by Reader 1 and Reader 2 was averaged and the average volume between readers acted as standard of reference value. Concordance between measurements was assessed using Lin's Concordance Correlation Coefficient (CCC). Limits of agreement (LoA) between readers and CT datasets were evaluated. Standard of reference nodule volume ranged from 13 to 366 mm 3 . The mean overestimation between readers was 3 mm 3 and 2.9 mm 3 on SCT and VSCT, respectively. Semi-automated volumetric measurements on VSCT showed substantial agreement with the standard of reference (Lin's CCC = 0.990 for Reader 1; 0.985 for Reader 2). The upper and lower LoA between readers' measurements were (16.3, -22.4 mm 3 ) and (15.5, -21.4 mm 3 ) for SCT and VSCT, respectively. VSCT datasets are feasible for the measurements of solid nodules, showing an almost perfect concordance between readers and with measurements on SCT. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    PubMed

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  13. Intimate Partner Aggression Reporting Concordance and Correlates of Agreement among Men with Alcohol Use Disorders and Their Female Partners

    ERIC Educational Resources Information Center

    Panuzio, Jillian; O'Farrell, Timothy J.; Marshall, Amy D.; Murphy, Christopher M.; Murphy, Marie; Taft, Casey T.

    2006-01-01

    This study examined relationship aggression reporting concordance among 303 men with alcohol use disorders and their female partners enrolled in couples-based alcohol abuse treatment. Agreement for physical and psychological aggression was generally consistent with, or higher than, concordance rates reported among other populations. Men's…

  14. An observational study of agreement between percentage pain reduction calculated from visual analog or numerical rating scales versus that reported by parturients during labor epidural analgesia.

    PubMed

    Pratici, E; Nebout, S; Merbai, N; Filippova, J; Hajage, D; Keita, H

    2017-05-01

    This study aimed to determine the level of agreement between calculated percentage pain reduction, derived from visual analog or numerical rating scales, and patient-reported percentage pain reduction in patients having labor epidural analgesia. In a prospective observational study, parturients were asked to rate their pain intensity on a visual analog scale and numerical rating scale, before and 30min after initiation of epidural analgesia. The percentage pain reduction 30min after epidural analgesia was calculated by the formula: 100×(score before epidural analgesia-score 30min after epidural analgesia)/score before epidural analgesia. To evaluate agreement between calculated percentage pain reduction and patient-reported percentage pain reduction, we computed the concordance correlation coefficient and performed Bland-Altman analysis. Ninety-seven women in labor were enrolled in the study, most of whom were nulliparous, with a singleton fetus and in spontaneous labor. The concordance correlation coefficient with patient-reported percentage pain reduction was 0.76 (95% CI 0.6 to 0.8) and 0.77 (95% CI 0.6 to 0.8) for the visual analog and numerical rating scale, respectively. The Bland-Altman mean difference between calculated percentage pain reduction and patient-reported percentage pain reduction for the visual analog and numerical rating scales was -2.0% (limits of agreement at 29.8%) and 0 (limits of agreement at 28.2%), respectively. The agreement between calculated percentage pain reduction from a visual analog or numerical rating scale and patient-reported percentage pain reduction in the context of labor epidural analgesia was moderate. The difference could range up to 30%. Patient-reported percentage pain reduction has advantages as a measurement tool for assessing pain management for childbirth but differences compared with other assessment methods should be taken into account. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    PubMed

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis. Furthermore, this approach demonstrated higher interobserver and intraobserver reliability as well as a better time efficiency when compared to visual analysis.

  16. Degree-Day Prediction Models for the Flight Phenology of Western Bean Cutworm (Lepidoptera: Noctuidae) Assessed with the Concordance Correlation Coefficient.

    PubMed

    Hanson, A A; Moon, R D; Wright, R J; Hunt, T E; Hutchison, W D

    2015-08-01

    Western bean cutworm, Striacosta albicosta (Smith) (Lepidoptera: Noctuidae), is a native, univoltine pest of corn and dry beans in North America. The current degree-day model for predicting a specified percentage of yearly moth flight involves heat unit accumulation above 10°C after 1 May. However, because the moth's observed range has expanded into the northern and eastern United States, there is concern that suitable temperatures before May could allow for significant S. albicosta development. Daily blacklight moth catch and temperature data from four Nebraska locations were used to construct degree-day models using simple or sine-wave methods, starting dates between 1 January and 1 May, and lower (-5 to 15°C) and upper (20 to 43.3°C) developmental thresholds. Predicted dates of flight from these models were compared with observed flight dates using independent datasets to assess model performance. Model performance was assessed with the concordance correlation coefficient to concurrently evaluate precision and accuracy. The best model for predicting timing of S. albicosta flight used simple degree-day calculations beginning on 1 March, a 3.3°C (38°F) lower threshold, and a 23.9°C (75°F) upper threshold. The revised cumulative flight model indicated field scouting to estimate moth egg density at the time of 25% flight should begin when 1,432 degree-days (2,577 degree-days °F) have accumulated. These results underscore the importance of assessing multiple parameters in phenological models and utilizing appropriate assessment methods, which in this case may allow for improved timing of field scouting for S. albicosta. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Concordance between maternal recall of birth complications and data from obstetrical records.

    PubMed

    Keenan, Kate; Hipwell, Alison; McAloon, Rose; Hoffmann, Amy; Mohanty, Arpita; Magee, Kelsey

    2017-02-01

    Prenatal complications are associated with poor outcomes in the offspring. Access to medical records is limited in the United States and investigators often rely on maternal report of prenatal complications. We tested concordance between maternal recall and birth records in a community-based sample of mothers participating in a longitudinal study in order to determine the accuracy of maternal recall of perinatal complications. Participants were 151 biological mothers, who were interviewed about gestational age at birth, birthweight, and the most commonly occurring birth complications: nuchal cord and meconium aspiration when the female child was on average 6years old, and for whom birth records were obtained. Concordance between reports was assessed using one-way random intra-class coefficients for continuous measures and kappa coefficients for dichotomous outcomes. Associations between maternal demographic and psychological factors and discrepancies also were tested. Concordance was excellent for continuously measured birthweight (ICC=0.85, p<0.001) and good for gestational age (ICC=0.68, p<0.001). Agreement was good for low birthweight (<2500g) (kappa=0.67, p<0.001), fair for preterm delivery (<37weeks gestation) (kappa=0.44, p<0.001), and poor for nuchal cord or meconium aspiration. Most discrepancies were characterized by presence according to birth record and absence according to maternal recall. Receipt of public assistance was associated with a decrease in discrepancy in report of nuchal cord. Concordance between maternal retrospective report and medical birth records varies across different types of perinatal events. There was little evidence that demographic or psychological factors increased the risk of discrepancies. Maternal recall based on continuous measures of perinatal factors may yield more valid data than dichotomous outcomes. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  18. Evaluation of an Immunocapture-Agglutination Test (Brucellacapt) for Serodiagnosis of Human Brucellosis

    PubMed Central

    Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez

    2000-01-01

    We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers are lower, they increase significantly in the following 30 days, despite the evolution of SAT titers. In contrast, Brucellacapt and Coombs titers are always high (≥1/640) in brucellosis with long evolution, whether SAT titers are higher or lower than 1/160. PMID:11060059

  19. The Edematous and Erythematous Airway Does Not Denote Pathologic Gastroesophageal Reflux.

    PubMed

    Rosen, Rachel; Mitchell, Paul D; Amirault, Janine; Amin, Manali; Watters, Karen; Rahbar, Reza

    2017-04-01

    To determine if the reflux finding score (RFS), a validated score for airway inflammation, correlates with gastroesophageal reflux measured by multichannel intraluminal impedance (MII) testing, endoscopy, and quality of life scores. We performed a prospective, cross-sectional cohort study of 77 children with chronic cough undergoing direct laryngoscopy and bronchoscopy, esophagogastroduodenoscopy, and MII testing with pH (pH-MII) between 2006 and 2011. Airway examinations were videotaped and reviewed by 3 blinded otolaryngologists each of whom assigned RFS to the airways. RFS were compared with the results of reflux testing (endoscopy, MII, symptom scores). An intraclass correlation coefficient was calculated for the degree of agreement between otolaryngologists' RFS. Receiver operating characteristic curves were created to determine the sensitivity of the RFS. Spearman correlation was calculated between the RFS and reflux measurements by pH-MII. The mean ± SD RFS was 12 ± 4. There was no correlation between pH-MII variables and mean RFS (|r| < 0.15). The concordance correlation coefficient for RFS between otolaryngologists was low (intraclass correlation coefficient = 0.32). Using pH-metry as a gold standard, the positive predictive value for the RFS was 29%. Using MII as the gold standard, the positive predictive value for the RFS was 40%. There was no difference in the mean RFS in patients with (12 ± 4) and without (12 ± 3) esophagitis (P = .9). There was no correlation between RFS and quality of life scores (|r| < 0.15, P > .3). The RFS cannot predict pathologic gastroesophageal reflux and an airway examination should not be used as a basis for prescribing gastroesophageal reflux therapies. Copyright © 2016. Published by Elsevier Inc.

  20. Evaluation of hirst-type spore trap to monitor environmental fungal load in hospital

    PubMed Central

    Gustin, Marie-Paule; Cassier, Pierre; Loeffert, Sophie Tiphaine; Thibaudon, Michel; Bénet, Thomas; Vanhems, Philippe

    2017-01-01

    The main purpose was to validate the use of outdoor-indoor volumetric impaction sampler with Hirst-type spore traps (HTSTs) to continuously monitor fungal load in order to prevent invasive fungal infections during major structural work in hospital settings. For 4 weeks, outdoor fungal loads were quantified continuously by 3 HTSTs. Indoor air was sampled by both HTST and viable impaction sampler. Results were expressed as particles/m3 (HTST) or colony-forming units (CFU)/m3 (biocollector). Paired comparisons by day were made with Wilcoxon’s paired signed-rank test or paired Student’s t-test as appropriate. Paired airborne spore levels were correlated 2 by 2, after log-transformation with Pearson’s cross-correlation. Concordance was calculated with kappa coefficient (κ). Median total fungal loads (TFLs) sampled by the 3 outdoor HTSTs were 3,025.0, 3,287.5 and 3,625.0 particles/m3 (P = 0.6, 0.6 and 0.3).—Concordance between Aspergillaceae fungal loads (AFLs, including Aspergillus spp. + Penicillium spp.) was low (κ = 0.2). A low positive correlation was found between TFLs sampled with outdoor HTST and indoor HTST with applying a 4-hour time lag, r = 0.30, 95% CI (0.23–0.43), P<0.001. In indoor air, Aspergillus spp. were detected by the viable impaction sampler on 63.1% of the samples, whereas AFLs were found by HTST-I on only 3.6% of the samples. Concordance between Aspergillus spp. loads and AFLs sampled with the 2 methods was very low (κ = 0.1). This study showed a 4-hour time lag between increase of outdoor and indoor TFLs, possibly due to insulation and aeraulic flow of the building. Outdoor HTSTs may permit to quickly identify (after 48 hours) time periods with high outdoor fungal loads. An identified drawback is that a too low sample area read did not seem to enable detection of Aspergillaceae spores efficiently. Indoor HTSTs may not be recommended at this time, and outdoor HTSTs need further study. Air sampling by viable impaction sampler remains the reference tool for quantifying fungal contamination of indoor air in hospitals. PMID:28486534

  1. Evaluation of hirst-type spore trap to monitor environmental fungal load in hospital.

    PubMed

    Dananché, Cédric; Gustin, Marie-Paule; Cassier, Pierre; Loeffert, Sophie Tiphaine; Thibaudon, Michel; Bénet, Thomas; Vanhems, Philippe

    2017-01-01

    The main purpose was to validate the use of outdoor-indoor volumetric impaction sampler with Hirst-type spore traps (HTSTs) to continuously monitor fungal load in order to prevent invasive fungal infections during major structural work in hospital settings. For 4 weeks, outdoor fungal loads were quantified continuously by 3 HTSTs. Indoor air was sampled by both HTST and viable impaction sampler. Results were expressed as particles/m3 (HTST) or colony-forming units (CFU)/m3 (biocollector). Paired comparisons by day were made with Wilcoxon's paired signed-rank test or paired Student's t-test as appropriate. Paired airborne spore levels were correlated 2 by 2, after log-transformation with Pearson's cross-correlation. Concordance was calculated with kappa coefficient (κ). Median total fungal loads (TFLs) sampled by the 3 outdoor HTSTs were 3,025.0, 3,287.5 and 3,625.0 particles/m3 (P = 0.6, 0.6 and 0.3).-Concordance between Aspergillaceae fungal loads (AFLs, including Aspergillus spp. + Penicillium spp.) was low (κ = 0.2). A low positive correlation was found between TFLs sampled with outdoor HTST and indoor HTST with applying a 4-hour time lag, r = 0.30, 95% CI (0.23-0.43), P<0.001. In indoor air, Aspergillus spp. were detected by the viable impaction sampler on 63.1% of the samples, whereas AFLs were found by HTST-I on only 3.6% of the samples. Concordance between Aspergillus spp. loads and AFLs sampled with the 2 methods was very low (κ = 0.1). This study showed a 4-hour time lag between increase of outdoor and indoor TFLs, possibly due to insulation and aeraulic flow of the building. Outdoor HTSTs may permit to quickly identify (after 48 hours) time periods with high outdoor fungal loads. An identified drawback is that a too low sample area read did not seem to enable detection of Aspergillaceae spores efficiently. Indoor HTSTs may not be recommended at this time, and outdoor HTSTs need further study. Air sampling by viable impaction sampler remains the reference tool for quantifying fungal contamination of indoor air in hospitals.

  2. Exact and efficient simulation of concordant computation

    NASA Astrophysics Data System (ADS)

    Cable, Hugo; Browne, Daniel E.

    2015-11-01

    Concordant computation is a circuit-based model of quantum computation for mixed states, that assumes that all correlations within the register are discord-free (i.e. the correlations are essentially classical) at every step of the computation. The question of whether concordant computation always admits efficient simulation by a classical computer was first considered by Eastin in arXiv:quant-ph/1006.4402v1, where an answer in the affirmative was given for circuits consisting only of one- and two-qubit gates. Building on this work, we develop the theory of classical simulation of concordant computation. We present a new framework for understanding such computations, argue that a larger class of concordant computations admit efficient simulation, and provide alternative proofs for the main results of arXiv:quant-ph/1006.4402v1 with an emphasis on the exactness of simulation which is crucial for this model. We include detailed analysis of the arithmetic complexity for solving equations in the simulation, as well as extensions to larger gates and qudits. We explore the limitations of our approach, and discuss the challenges faced in developing efficient classical simulation algorithms for all concordant computations.

  3. Effects of Genital Response Measurement Device and Stimulus Characteristics on Sexual Concordance in Women.

    PubMed

    Bouchard, Katrina N; Chivers, Meredith L; Pukall, Caroline F

    2017-01-01

    Investigations of sexual concordance suggest that, on average, women exhibit a low, positive correlation between their subjective sexual arousal and genital response. However, this relationship appears to be stronger, on average, when genital response is measured via the external tissues of the vulva than within the vagina walls. Given the methodological variations, such as stimulus content and duration, in studies of vulvar and vaginal concordance, direct comparisons between individual studies are limited. In the current study, sexual concordance was examined using concurrent measures of vulvar blood flow (using laser Doppler imaging) and vaginal vasocongestion (using vaginal photoplethysmography) to investigate potential differences in vulvar and vaginal concordance. Twenty-five women viewed two erotic films that differed in sexual activity content (foreplay and intercourse) while their subjective sexual arousal and genital response was measured. In support of previous meta-analytic findings, results suggest that subjective sexual arousal is more strongly correlated with vulvar blood flow than with vaginal vasocongestion. Likewise, perceived genital response and actual vulvar blood flow are more strongly related than are vaginal vasocongestion and self-reported genital sensations. Practical implications for the study of women's sexual concordance as well as broader implications for the understanding of female sexuality are considered.

  4. Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.

    PubMed

    Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak

    2012-06-01

    Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the pulsatility index, the limits of agreement were -0.80 to 0.53. The correlation of the size of the measurement and the mean difference in methods (-0.14; 95% CI = -0.28, 0.01) was not statistically significant (r = 0.31, P = 0.17). For the resistive index, the limits of agreement were -0.22 to 0.12. The correlation of the size of the measurement and the mean difference in methods (-0.05; 95% CI = -0.09, -0.01) was not statistically significant (r = 0.10, P = 0.65). This study confirms the feasibility of obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children. Angle-independent TEE Doppler-derived indices show significant concordance with those derived by TAU. Further studies are required to assess whether this correlation holds true in the presence of renal pathology. This technique has the potential to help modulate intraoperative interventions based on their impact on renal variables and may prove helpful in the perioperative period for children at risk of acute kidney injury.

  5. A randomized trial to determine the diagnostic accuracy of conventional vs. jumbo forceps biopsy of gastric epithelial neoplasias before endoscopic submucosal dissection; open-label study.

    PubMed

    Jeon, Hyo Keun; Ryu, Ho Yoel; Cho, Mee Yon; Kim, Hyun-Soo; Kim, Jae Woo; Park, Hong Jun; Kim, Moon Young; Baik, Soon Koo; Kwon, Sang Ok; Park, Su Yeon; Won, Sung Ho

    2014-10-01

    Larger biopsy specimens or increasing the number of biopsies may improve the diagnostic accuracy of gastric epithelial neoplasia (GEN). The aims of this study was to compare the diagnostic accuracies between conventional and jumbo forceps biopsy of GEN before endoscopic submucosal dissection (ESD) and to confirm that increasing the number of biopsies is useful for the diagnosis of GEN. The concordance rate between EFB and ESD specimens was not significantly different between the two groups [83.1 % (54/65) in JG vs. 79.1 % (53/67) in CG]. On multivariate analyses, two or four EFBs significantly increased the cumulating concordance rate [coefficients; twice: 5.1 (P = 0.01), four times: 5.9 (P = 0.02)]. But, the concordance rate was decreased in high grade dysplasia (coefficient -40.32, P = 0.006). One hundred and sixty GENs from 148 patients were randomized into two groups and finally 67 GENs in 61 patients and 65 GENs in 63 patients were allocated to the conventional group (CG) or jumbo group (JG), respectively. Four endoscopic forceps biopsy (EFB) specimens were obtained from each lesion with conventional (6.8 mm) forceps or jumbo (8 mm) forceps. The histological concordance rate between 4 EFB specimens and ESD specimens was investigated in the two groups. Before ESD, the diagnostic accuracy of GENs was significantly increased not by the use of jumbo forceps biopsy but by increasing the number of biopsies.

  6. [Evaluation of the performances of the UF-1000i(®) automated urine analyzer].

    PubMed

    Fabbro, Christelle; Darolles, Jacques; Rault, Jean-Philippe

    2011-01-01

    The purpose of this study was the evaluation of the UF 1000i(®) automated urine analyzer (bioMérieux(©)).The coefficients of variation (CV) for the repeatability of the red blood cell (RBC), white blood cell (WBC) and bacteria counts were overall concordant with those announced by the supplier. However, for low concentrations, the CV for the repeatability for concentrations of 10(3) RBC/mL, 10(3) WBC/mL and 5×10(3) UA/mL were respectively of 26, 18 and 36% and thus higher than the CV (10%) reported for each of the three parameters by the supplier. Reproducibility results agreed with those given by the supplier (10%). The linearity range was different from that reported by the supplier and was shifted by a factor 10 for WBC and bacteria high concentrations. Cross contamination between samples was prevented by using the washing program recommended by the supplier which however led to a lower analysis frequency (80 samples per hour). Detection limits were of 5,7×10(1) RBC/mL, 5,7×10(1) WBC/mL and 1,6×10(4) UA/mL respectively for the RBC, WBC and bacteria. Quantification limits found in this study were of 1,3×10(3) RBC/mL, 1,7×10(3) WBC/mL, 5,1×10(3) UA/mL. An overestimation of the RBC count was observed within the range of 5×10(3) to 2×10(4) RBC/mL. Beyond this concentration range, the concordance is good. The correlation is poor within this range and good for higher concentrations. For WBC, concordance and correlation were satisfactory over the whole range tested.

  7. Prediction of subacute infarct size in acute middle cerebral artery stroke: comparison of perfusion-weighted imaging and apparent diffusion coefficient maps.

    PubMed

    Drier, Aurélie; Tourdias, Thomas; Attal, Yohan; Sibon, Igor; Mutlu, Gurkan; Lehéricy, Stéphane; Samson, Yves; Chiras, Jacques; Dormont, Didier; Orgogozo, Jean-Marc; Dousset, Vincent; Rosso, Charlotte

    2012-11-01

    To compare perfusion-weighted (PW) imaging and apparent diffusion coefficient (ADC) maps in prediction of infarct size and growth in patients with acute middle cerebral artery infarct. This study was approved by the local institutional review board. Written informed consent was obtained from all 80 patients. Subsequent infarct volume and growth on follow-up magnetic resonance (MR) images obtained within 6 days were compared with the predictions based on PW images by using a time-to-peak threshold greater than 4 seconds and ADC maps obtained less than 12 hours after middle cerebral artery infarct. ADC- and PW imaging-predicted infarct growth areas and infarct volumes were correlated with subsequent infarct growth and follow-up diffusion-weighted (DW) imaging volumes. The impact of MR imaging time delay on the correlation coefficient between the predicted and subsequent infarct volumes and individual predictions of infarct growth by using receiver operating characteristic curves were assessed. The infarct volume measurements were highly reproducible (concordance correlation coefficient [CCC] of 0.965 and 95% confidence interval [CI]: 0.949, 0.976 for acute DW imaging; CCC of 0.995 and 95% CI: 0.993, 0.997 for subacute DW imaging). The subsequent infarct volume correlated (P<.0001) with ADC- (ρ=0.853) and PW imaging- (ρ=0.669) predicted volumes. The correlation was higher for ADC-predicted volume than for PW imaging-predicted volume (P<.005), but not when the analysis was restricted to patients without recanalization (P=.07). The infarct growth correlated (P<.0001) with PW imaging-DW imaging mismatch (ρ=0.470) and ADC-DW imaging mismatch (ρ=0.438), without significant differences between both methods (P=.71). The correlations were similar among time delays with ADC-predicted volumes but decreased with PW imaging-based volumes beyond the therapeutic window. Accuracies of ADC- and PW imaging-based predictions of infarct growth in an individual prediction were similar (area under the receiver operating characteristic curve [AUC] of 0.698 and 95% CI: 0.585, 0.796 vs AUC of 0.749 and 95% CI: 0.640, 0.839; P=.48). The ADC-based method was as accurate as the PW imaging-based method for evaluating infarct growth and size in the subacute phase. © RSNA, 2012

  8. Concordance of the location of the innervation zone of the tibialis anterior muscle using voluntary and imposed contractions by electrostimulation.

    PubMed

    Guzmán-Venegas, R A; Bralic, M P; Cordero, J J; Cavada, G; Araneda, O F

    2016-04-01

    The innervation zone (IZ) corresponds to the location of the neuromuscular junctions. Its location can be determined by using arranged surface linear electrode arrays. Typically, voluntary muscle contractions (VC) are used in this method. However, it also may be necessary to locate the IZ under clinical conditions such as spasticity, in which this type of contraction is difficult to perform. Therefore, contractions imposed by electrostimulation (ES) can be an alternative. There is little background comparing the locations of IZ obtained by two different types of contractions. Evaluate the concordance between using voluntary and imposed contractions from electrostimulation in order to determine the location of the innervation zone of the tibialis anterior muscle in healthy volunteers. The tibialis anterior (TA) muscle of sixteen volunteers (men: 8; women: 8; age: 22.1±1.4years, weight: 61.6±7.5kg, height: 167.1±7.5cm) were evaluated using a linear electrode array. The IZ of the TA muscle was located using two types of muscle contractions, voluntary (10% MVC) and imposed contractions by ES. The concordance between both conditions was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). The analyses were applied to the absolute and relative positions to the length of an anatomical landmark frame. CCC for absolute position was 0.98 (p<0.0001, 95% CI [0.98-1.00], and CCC for relative positions also was 0.98 (p<0.0001, 95% CI [0.97-1.00]). The Bland-Altman analysis for absolute data showed an average difference of -0.63mm (SD: 4.1). Whereas, for adjusted data, the average difference was -0.20% (SD: 1.2). The power of the results, based on absolute data, was 98%, whereas for relative data, 82%. In healthy volunteers, there was a substantially concordance between the location of the IZ of the TA muscle derived from using contractions imposed by ES and the location derived from using VC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Prism under cover test in alternate fixation horizontal strabismus.

    PubMed

    Tejedor, Jaime; Gutiérrez-Carmona, Francisco José

    2018-02-01

    To evaluate the applicability of the prism under cover test (PUCT) to quantify manifest deviation in horizontal strabismus with alternate fixation when simultaneous prism and cover test (SPCT) is not feasible. Children aged 4-11 years, with alternate fixation horizontal strabismus and alternate prism and cover test (APCT) distance deviation (DD) up to 25 PD were eligible. In group 1 of the study, SPCT was not feasible (n = 18), whereas in group 2, it was feasible (n = 24). Refraction, PUCT, APCT, central/peripheral fusion, and stereoacuity were measured. Repeatability of PUCT, agreement between PUCT and SPCT, and Pearson correlations between variables were studied. In group 1, mean DD was 15.6 and 9.5 PD using APCT and PUCT, respectively (intraclass correlation, ICC: 0.90). Mean stereoacuity was 201.1 arc seconds. PUCT was better correlated with stereoacuity than APCT, but not significantly (p = 0.12). Coefficient of repeatability for PUCT was 3.4 PD. In group 2, mean DD was 17.6, 14.1, and 12.5 PD using APCT, PUCT, and SPCT, respectively. Mean stereoacuity was 285.9 arc seconds. Correlations APCT-PUCT (0.87), APCT-SPCT (0.82), and SPCT-PUCT (0.95) were significant. APCT did not show as good correlation with stereoacuity (0.58) as SPCT and PUCT (0.74 and 0.78, respectively). Concordance correlation coefficient between SPCT and PUCT was 0.91, and Bland Altman agreement between the two variables was also good. PUCT is a procedure with good repeatability, of interest in children to estimate manifest deviation when SPCT is not feasible, and in support of the diagnosis of monofixation syndrome.

  10. Comparison of the King's and MiToS staging systems for ALS.

    PubMed

    Fang, Ton; Al Khleifat, Ahmad; Stahl, Daniel R; Lazo La Torre, Claudia; Murphy, Caroline; Young, Carolyn; Shaw, Pamela J; Leigh, P Nigel; Al-Chalabi, Ammar

    2017-05-01

    To investigate and compare two ALS staging systems, King's clinical staging and Milano-Torino (MiToS) functional staging, using data from the LiCALS phase III clinical trial (EudraCT 2008-006891-31). Disease stage was derived retrospectively for each system from the ALS Functional Rating Scale-Revised subscores using standard methods. The two staging methods were then compared for timing of stages using box plots, correspondence using chi-square tests, agreement using a linearly weighted kappa coefficient and concordance using Spearman's rank correlation. For both systems, progressively higher stages occurred at progressively later proportions of the disease course, but the distribution differed between the two methods. King's stage 3 corresponded to MiToS stage 1 most frequently, with earlier King's stages 1 and 2 largely corresponding to MiToS stage 0 or 1. The Spearman correlation was 0.54. There was fair agreement between the two systems with kappa coefficient of 0.21. The distribution of timings shows that the two systems are complementary, with King's staging showing greatest resolution in early to mid-disease corresponding to clinical or disease burden, and MiToS staging having higher resolution for late disease, corresponding to functional involvement. We therefore propose using both staging systems when describing ALS.

  11. Excellent Intra and Inter-Observer Reproducibility of Wrist Circumference Measurements in Obese Children and Adolescents

    PubMed Central

    Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella

    2016-01-01

    In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398

  12. Global clinical response in Cushing’s syndrome patients treated with mifepristone

    PubMed Central

    Katznelson, Laurence; Loriaux, D Lynn; Feldman, David; Braunstein, Glenn D; Schteingart, David E; Gross, Coleman

    2014-01-01

    Objective Mifepristone, a glucocorticoid receptor antagonist, improves clinical status in patients with Cushing’s syndrome (CS). We examined the pattern, reliability and correlates of global clinical response (GCR) assessments during a 6-month clinical trial of mifepristone in CS. Design Post hoc analysis of secondary end-point data from a 24-week multicentre, open-label trial of mifepristone (300–1200mg daily) in CS. Intraclass correlation coefficient (ICC) was used to examine rater concordance, and drivers of clinical improvement were determined by multivariate regression analysis. Patients Forty-six adult patients with refractory CS along with diabetes mellitus type 2 or impaired glucose tolerance, and/or a diagnosis of hypertension. Measurements Global clinical assessment made by three independent reviewers using a three-point ordinal scale (+1 = improvement; 0=no change; −1=worsening) based on eight broad clinical categories including glucose control, lipids, blood pressure, body composition, clinical appearance, strength, psychiatric/cognitive symptoms and quality of life at Weeks 6, 10, 16, and 24. Results Positive GCR increased progressively over time with 88% of patients having improved at Week 24 (P<0·001). The full concordance among reviewers occurred in 76·6% of evaluations resulting in an ICC of 0·652 (P<0·001). Changes in body weight (P<0·0001), diastolic blood pressure (P<0·0001), two-hour postoral glucose challenge glucose concentration (P = 0·0003), and Cushingoid appearance (P=0·022) were strong correlates of GCR. Conclusions Mifepristone treatment for CS results in progressive clinical improvement. Overall agreement among clinical reviewers was substantial and determinants of positive GCR included change in weight, blood pressure, glucose levels and appearance. PMID:24102404

  13. [Classification of Colombian children with malnutrition according to NCHS reference or WHO standard].

    PubMed

    Velásquez, Claudia; Bermúdez, Juliana; Echeverri, Claudia; Estrada, Alejandro

    2011-12-01

    A descriptive study was conducted to evaluate the concordance of National Center for Health Statistics reference (NCHS) used to classify undernourished children from Colombia with the WHO Child Growth Standards. We used data from children aged 6 to 59 months with acute malnutrition (Z <-2) and severe (Z <-3) who were admitted to the "Unidad Vida Infantil" nutrition program in Colombia. Indicators height-for-age, weight for-height were analyzed when they were admitted to the hospital and weight for-height leaving the hospital. A statistical method used to compare means was T-student. Correlation coefficient intraclass (CCI) and Kappa index evaluated the concordance between NCHS and OMS; McNemar method evaluated the changes on the nutritional classification for children according to growth devices used. Of the total number of children classified as normal by NCHS, 10.4% were classified as stunted by WHO. 64% of the children admitted to the hospital presented acute malnutrition according to NCHS, of these 44,8% presented severe emaciation according to OMS, indeed severe emaciation increased of 36,0% to 63,3% using OMS. 5% of children leaving the hospital could need to stay more days if they had been evaluated with OMS. Growth devices shown high concordance in height-for-age (CCI = 0,988; k= 0,866) and weight for-height (CCI = 0,901; k = 0,578). Concluded that OMS growth standards classified more malnourished children and more severe states, in addition more malnourished children could be hospitalized and they could stay more days.

  14. Measuring Age-Dependent Myocardial Stiffness across the Cardiac Cycle using MR Elastography: A Reproducibility Study

    PubMed Central

    Wassenaar, Peter A; Eleswarpu, Chethanya N; Schroeder, Samuel A; Mo, Xiaokui; Raterman, Brian D; White, Richard D; Kolipaka, Arunark

    2015-01-01

    Purpose To assess reproducibility in measuring left ventricular (LV) myocardial stiffness in volunteers throughout the cardiac cycle using magnetic resonance elastography (MRE) and to determine its correlation with age. Methods Cardiac MRE (CMRE) was performed on 29 normal volunteers, with ages ranging from 21 to 73 years. For assessing reproducibility of CMRE-derived stiffness measurements, scans were repeated per volunteer. Wave images were acquired throughout the LV myocardium, and were analyzed to obtain mean stiffness during the cardiac cycle. CMRE-derived stiffness values were correlated to age. Results Concordance correlation coefficient revealed good inter-scan agreement with rc of 0.77, with p-value<0.0001. Significantly higher myocardial stiffness was observed during end-systole (ES) compared to end-diastole (ED) across all subjects. Additionally, increased deviation between ES and ED stiffness was observed with increased age. Conclusion CMRE-derived stiffness is reproducible, with myocardial stiffness changing cyclically across the cardiac cycle. Stiffness is significantly higher during ES compared to ED. With age, ES myocardial stiffness increases more than ED, giving rise to an increased deviation between the two. PMID:26010456

  15. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise

    PubMed Central

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall’s coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index. PMID:29410564

  16. CONCORDANCE OF TAXONOMIC RICHNESS PATTERNS ACROSS MULTIPLE ASSEMBLAGES IN LAKES OF THE NORTHEASTERN UNITED STATES

    EPA Science Inventory

    We investigated the concordance of taxonomic richness patterns and their environmental correlates for assemblages of benthic macroinvertebrates, riparian birds, sedimentary diatoms, fish, planktonic crustaceans, and planktonic rotifers in 186 northeastern U.S. lakes. Taxon counts...

  17. Comparative Assessment of the Cleft Profile by Patients with Cleft Lip and Palate, Cleft Surgeons, and Lay People.

    PubMed

    Meng, Tian; Ma, Lian; Wang, Zhi

    2015-10-01

    This cross-sectional study aimed to compare subjective assessments among patients with cleft lip and palate (CLP), cleft surgeons, and lay people regarding the soft tissue lateral profile of CLP patients. We also investigated the correlations between subjective assessments and photogrammetric measurements. A total of 150 CLP patients who wished to have treatment for their unattractive appearance were randomly selected. A standard lateral profile color photograph was taken. Panels of three cleft surgeons, ten CLP patients, and ten lay people were selected to be assessors. They rated nasal tip projection, nasolabial esthetics, upper and lower lip esthetics, and the profile for each photograph. Three angular measurements (nasal prominence angle, nasolabial angle, and lip angle) were measured for each photograph. Kendall's coefficient of concordance and logistic regression were used for statistical analysis. Kendall's coefficient of concordance of nasal tip projection, nasolabial esthetics, upper and lower lip esthetics, and the profile were 0.734, 0.683, 0.828, and 0.747, respectively (p < 0.001). Lip angle was associated with the profile scores for cleft surgeons and CLP patients (p < 0.001). The nasal prominence angle and lip angle were associated with the profile scores for lay people (p < 0.001). CLP patients, cleft surgeons, and lay people have similar attitudes to the appearance of CLP patients. Upper and lower lip esthetics is associated with the assessment of the cleft profile that is provided by CLP patients, cleft surgeons, and lay people. In addition, nasal tip projection is another determining factor for lay people. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  18. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.

    PubMed

    Sun, Jing; Chen, Hanjian; Zheng, Jun; Mao, Bin; Zhu, Shengmei; Feng, Jingyi

    2017-12-01

    Radial artery applanation tonometry (RAAT) has been developed and utilized for continuous arterial pressure monitoring. However, evidence is lacking to clinically verify the RAAT technology and identify appropriate patient groups before routine clinical use. This study aims to evaluate the RAAT technology by comparing systolic blood pressure (SBP), mean blood pressure (MBP) and diastolic blood pressure (DBP) values in patients undergoing colon carcinoma surgery. Blood Pressure (BP) values obtained via RAAT (TL-300, Tensys Medical Inc., San Diego, CA, USA) and conventional arterial catheterization from 30 colon carcinoma surgical patients were collected and compared via Bland-Atman method, linear regression and 4-quadrant plot concordance analysis. For SBPs, MBPs and DBPs, means of the differences (±standard deviation; 95% limits of agreement) were -0.9 (±7.6; -15.7 to 13.9) mmHg, 3.1 (±6.5; -9.6 to 15.8) mmHg and 4.3 (±7.4; -10.3 to 18.8) mmHg, respectively. Linear regression coefficients of determination were 0.8706 for SBPs, 0.8353 for MBPs and 0.6858 for DBPs. Four-quadrant concordance correlation coefficients were 0.8740, 0.8522 and 0.7108 for SBPs, MBPs and DBPs, respectively. A highly selected patient collective undergoing colon carcinoma surgery was studied. BP measurements obtained via the TL-300 had clinically acceptable agreement with that acquired invasively using an arterial catheter. For use in clinical routine, it is necessary to take measures for improvement regarding movement artifacts and dilution of noise. A large sample size of patients under various conditions is also needed to further evaluate the RAAT technology before clinically routine use.

  19. Reliability of TMS metrics in patients with chronic incomplete spinal cord injury.

    PubMed

    Potter-Baker, K A; Janini, D P; Frost, F S; Chabra, P; Varnerin, N; Cunningham, D A; Sankarasubramanian, V; Plow, E B

    2016-11-01

    Test-retest reliability analysis in individuals with chronic incomplete spinal cord injury (iSCI). The purpose of this study was to examine the reliability of neurophysiological metrics acquired with transcranial magnetic stimulation (TMS) in individuals with chronic incomplete tetraplegia. Cleveland Clinic Foundation, Cleveland, Ohio, USA. TMS metrics of corticospinal excitability, output, inhibition and motor map distribution were collected in muscles with a higher MRC grade and muscles with a lower MRC grade on the more affected side of the body. Metrics denoting upper limb function were also collected. All metrics were collected at two sessions separated by a minimum of two weeks. Reliability between sessions was determined using Spearman's correlation coefficients and concordance correlation coefficients (CCCs). We found that TMS metrics that were acquired in higher MRC grade muscles were approximately two times more reliable than those collected in lower MRC grade muscles. TMS metrics of motor map output, however, demonstrated poor reliability regardless of muscle choice (P=0.34; CCC=0.51). Correlation analysis indicated that patients with more baseline impairment and/or those in a more chronic phase of iSCI demonstrated greater variability of metrics. In iSCI, reliability of TMS metrics varies depending on the muscle grade of the tested muscle. Variability is also influenced by factors such as baseline motor function and time post SCI. Future studies that use TMS metrics in longitudinal study designs to understand functional recovery should be cautious as choice of muscle and clinical characteristics can influence reliability.

  20. Relative and absolute reliability of measures of linoleic acid-derived oxylipins in human plasma.

    PubMed

    Gouveia-Figueira, Sandra; Bosson, Jenny A; Unosson, Jon; Behndig, Annelie F; Nording, Malin L; Fowler, Christopher J

    2015-09-01

    Modern analytical techniques allow for the measurement of oxylipins derived from linoleic acid in biological samples. Most validatory work has concerned extraction techniques, repeated analysis of aliquots from the same biological sample, and the influence of external factors such as diet and heparin treatment upon their levels, whereas less is known about the relative and absolute reliability of measurements undertaken on different days. A cohort of nineteen healthy males were used, where samples were taken at the same time of day on two occasions, at least 7 days apart. Relative reliability was assessed using Lin's concordance correlation coefficients (CCC) and intraclass correlation coefficients (ICC). Absolute reliability was assessed by Bland-Altman analyses. Nine linoleic acid oxylipins were investigated. ICC and CCC values ranged from acceptable (0.56 [13-HODE]) to poor (near zero [9(10)- and 12(13)-EpOME]). Bland-Altman limits of agreement were in general quite wide, ranging from ±0.5 (12,13-DiHOME) to ±2 (9(10)-EpOME; log10 scale). It is concluded that relative reliability of linoleic acid-derived oxylipins varies between lipids with compounds such as the HODEs showing better relative reliability than compounds such as the EpOMEs. These differences should be kept in mind when designing and interpreting experiments correlating plasma levels of these lipids with factors such as age, body mass index, rating scales etc. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Comparison of McMaster and FECPAKG2 methods for counting nematode eggs in the faeces of alpacas.

    PubMed

    Rashid, Mohammed H; Stevenson, Mark A; Waenga, Shea; Mirams, Greg; Campbell, Angus J D; Vaughan, Jane L; Jabbar, Abdul

    2018-05-02

    This study aimed to compare the FECPAK G2 and the McMaster techniques for counting of gastrointestinal nematode eggs in the faeces of alpacas using two floatation solutions (saturated sodium chloride and sucrose solutions). Faecal eggs counts from both techniques were compared using the Lin's concordance correlation coefficient and Bland and Altman statistics. Results showed moderate to good agreement between the two methods, with better agreement achieved when saturated sugar is used as a floatation fluid, particularly when faecal egg counts are less than 1000 eggs per gram of faeces. To the best of our knowledge this is the first study to assess agreement of measurements between McMaster and FECPAK G2 methods for estimating faecal eggs in South American camelids.

  2. Adaptive Spatial Filter Based on Similarity Indices to Preserve the Neural Information on EEG Signals during On-Line Processing

    PubMed Central

    Villa-Parra, Ana Cecilia; Bastos-Filho, Teodiano; López-Delis, Alberto; Frizera-Neto, Anselmo; Krishnan, Sridhar

    2017-01-01

    This work presents a new on-line adaptive filter, which is based on a similarity analysis between standard electrode locations, in order to reduce artifacts and common interferences throughout electroencephalography (EEG) signals, but preserving the useful information. Standard deviation and Concordance Correlation Coefficient (CCC) between target electrodes and its correspondent neighbor electrodes are analyzed on sliding windows to select those neighbors that are highly correlated. Afterwards, a model based on CCC is applied to provide higher values of weight to those correlated electrodes with lower similarity to the target electrode. The approach was applied to brain computer-interfaces (BCIs) based on Canonical Correlation Analysis (CCA) to recognize 40 targets of steady-state visual evoked potential (SSVEP), providing an accuracy (ACC) of 86.44 ± 2.81%. In addition, also using this approach, features of low frequency were selected in the pre-processing stage of another BCI to recognize gait planning. In this case, the recognition was significantly (p<0.01) improved for most of the subjects (ACC≥74.79%), when compared with other BCIs based on Common Spatial Pattern, Filter Bank-Common Spatial Pattern, and Riemannian Geometry. PMID:29186848

  3. Objective assessment of isotretinoin-associated cheilitis: Isotretinoin Cheilitis Grading Scale.

    PubMed

    Ornelas, Jennifer; Rosamilia, Lorraine; Larsen, Larissa; Foolad, Negar; Wang, Quinlu; Li, Chin-Shang; Sivamani, Raja K

    2016-01-01

    Isotretinoin remains an effective treatment for severe acne. Despite its effectiveness, it includes many side effects, of which cheilitis is the most common. To develop an objective grading scale for assessment of isotretinoin-associated cheilitis. Cross-sectional clinical grading study. UC Davis Dermatology clinic. Subjects were older than 18 years old and actively treated with oral isotretinoin. Oral Isotretinoin. We developed an Isotretinoin Cheilitis Grading Scale (ICGS) incorporating the following four characteristics: erythema, scale/crust, fissures and inflammation of the commissures. Three board-certified dermatologists independently graded photographs of the subjects. The Kendall's coefficient of concordance (KCC) for the ICGS was 0.88 (p < 0.0001). The Kendall's coefficient was ≥0.72 (p < 0.0001) for each of the four characteristics included in the grading scale. An image-based measurement for lip roughness statistically significantly correlated with the lip scale/crusting assessment (r = 0.52, p < 0.05). The ICGS is reproducible and relatively simple to use. It can be incorporated as an objective tool to aid in the assessment of isotretinoin associated cheilitis.

  4. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage.

    PubMed

    Mennecke, Angelika; Svergun, Stanislav; Scholz, Bernhard; Royalty, Kevin; Dörfler, Arnd; Struffert, Tobias

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. • After coiling subarachnoid haemorrhage, metal artefacts seriously reduce FD-CT image quality. • This new metal artefact reduction algorithm is feasible for flat-detector CT. • After coiling, MAR is necessary for diagnostic quality of affected slices. • Slice-wise Pearson correlation is introduced to evaluate improvement of MAR in future studies. • Metal-unaffected parts of image are not modified by this MAR algorithm.

  5. Factors affecting the precision of lesion sizing with contrast-enhanced spectral mammography.

    PubMed

    Travieso-Aja, M Del Mar; Naranjo-Santana, P; Fernández-Ruiz, C; Severino-Rondón, W; Maldonado-Saluzzi, D; Rodríguez Rodríguez, M; Vega-Benítez, V; Luzardo, O P

    2018-03-01

    To evaluate the precision of the pre-surgical measurement of the size of breast cancer by contrast-enhanced spectral mammography (CESM). This was a retrospective study of 204 breast cancers. Variables related to tumour biology and anthropometric variables were recorded and considered when evaluating the efficacy of CESM in predicting tumour size. Microscopic measurement of the largest diameter of the tumour at pathology was chosen as the reference standard. The mean size of tumours at pathology was 20.7±15.8 mm, while at CESM it was 23.6±16.7 mm (Bland-Altman 2.9 mm overestimation, 2.9 mm; 95% confidence interval [CI]: -10.3-16.2 mm). Spearman's correlation coefficient was 0.83 (p<0.0001). The concordance analysis indicated that 37.8% of the measurements were concordant, 47% were overestimated, and 15.2% were underestimated. Tumour size, nodal involvement, breast density, and breast size significantly modified the sizing accuracy. Quality of tumour size prediction with CESM is good, and this appears to be a promising imaging technique in the surgical planning of breast cancer. Biological tumour features, and anthropological characteristics of the patients do, however, affect the diagnostic precision and should be taken into account. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Comparison of Short-Wavelength Reduced-Illuminance and Conventional Autofluorescence Imaging in Stargardt Macular Dystrophy.

    PubMed

    Strauss, Rupert W; Muñoz, Beatriz; Jha, Anamika; Ho, Alexander; Cideciyan, Artur V; Kasilian, Melissa L; Wolfson, Yulia; Sadda, SriniVas; West, Sheila; Scholl, Hendrik P N; Michaelides, Michel

    2016-08-01

    To compare grading results between short-wavelength reduced-illuminance and conventional autofluorescence imaging in Stargardt macular dystrophy. Reliability study. setting: Moorfields Eye Hospital, London (United Kingdom). Eighteen patients (18 eyes) with Stargardt macular dystrophy. A series of 3 fundus autofluorescence images using 3 different acquisition parameters on a custom-patched device were obtained: (1) 25% laser power and total sensitivity 87; (2) 25% laser power and freely adjusted sensitivity; and (3) 100% laser power and freely adjusted total sensitivity (conventional). The total area of 2 hypoautofluorescent lesion types (definitely decreased autofluorescence and poorly demarcated questionably decreased autofluorescence) was measured. Agreement in grading between the 3 imaging methods was assessed by kappa coefficients (κ) and intraclass correlation coefficients. The mean ± standard deviation area for images acquired with 25% laser power and freely adjusted total sensitivity was 2.04 ± 1.87 mm(2) for definitely decreased autofluorescence (n = 15) and 1.86 ± 2.14 mm(2) for poorly demarcated questionably decreased autofluorescence (n = 12). The intraclass correlation coefficient (95% confidence interval) was 0.964 (0.929, 0.999) for definitely decreased autofluorescence and 0.268 (0.000, 0.730) for poorly demarcated questionably decreased autofluorescence. Short-wavelength reduced-illuminance and conventional fundus autofluorescence imaging showed good concordance in assessing areas of definitely decreased autofluorescence. However, there was significantly higher variability between imaging modalities for assessing areas of poorly demarcated questionably decreased autofluorescence. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. The relationship between sexual concordance and interoception in anxious and nonanxious women.

    PubMed

    Suschinsky, Kelly D; Lalumière, Martin L

    2014-04-01

    Sexual concordance refers to the association between physiological and self-reported sexual arousal. Women typically exhibit lower sexual concordance scores than men. There is also a sex difference in interoception--awareness of (nonsexual) physiological states or responses--such that women, compared with men, tend to be less aware of and less accurate at detecting changes in their physiological responses. Women with anxiety problems tend to have better interoceptive abilities than nonanxious women. To investigate whether women's lower sexual concordance is associated with interoception using a sample likely to show high variation in interoceptive abilities. Sixteen anxious and 15 nonanxious women were presented with twelve 90 seconds sexual and nonsexual film clips while their genital response, heart rate, and respiration rate were measured. A heartbeat mental tracking task was also employed. Genital response was measured with a vaginal photoplethysmograph. Heart rate was measured with an electrocardiogram and respiration rate with a thermistor. Participants estimated their physiological responses after each film. A mental tracking task was also used to assess participants' awareness of heart rate. Within-subject correlations were computed for each physiological/self-reported response combination. Overall, sexual concordance (i.e., the correlation between genital responses and perceptions of genital response) was not significantly associated with heart rate awareness or respiration rate awareness. Anxious women did not exhibit significantly higher sexual concordance or heart rate awareness than nonanxious women; the nonanxious women actually exhibited higher respiration rate awareness. The results suggest that sexual concordance may be a distinct phenomenon from interoception and in need of its own explanation. © 2013 International Society for Sexual Medicine.

  8. Short communication: Evaluation of the PREP10 energy-, protein-, and amino acid-allowable milk equations in comparison with the National Research Council model.

    PubMed

    White, Robin R; McGill, Tyler; Garnett, Rebecca; Patterson, Robert J; Hanigan, Mark D

    2017-04-01

    The objective of this work was to evaluate the precision and accuracy of the milk yield predictions made by the PREP10 model in comparison to those from the National Research Council (NRC) Nutrient Requirements of Dairy Cattle. The PREP10 model is a ration-balancing system that allows protein use efficiency to vary with production level. The model also has advanced AA supply and requirement calculations that enable estimation of AA-allowable milk (Milk AA ) based on 10 essential AA. A literature data set of 374 treatment means was collected and used to quantitatively evaluate the estimates of protein-allowable milk (Milk MP ) and energy-allowable milk yields from the NRC and PREP10 models. The PREP10 Milk AA prediction was also evaluated, as were both models' estimates of milk based on the most-limiting nutrient or the mean of the estimated milk yields. For most milk estimates compared, the PREP10 model had reduced root mean squared prediction error (RMSPE), improved concordance correlation coefficient, and reduced mean and slope bias in comparison to the NRC model. In particular, utilizing the variable protein use efficiency for milk production notably improved the estimate of Milk MP when compared with NRC. The PREP10 Milk MP estimate had an RMSPE of 18.2% (NRC = 25.7%), concordance correlation coefficient of 0.82% (NRC = 0.64), slope bias of -0.14 kg/kg of predicted milk (NRC = -0.34 kg/kg), and mean bias of -0.63 kg (NRC = -2.85 kg). The PREP10 estimate of Milk AA had slightly elevated RMSPE and mean and slope bias when compared with Milk MP . The PREP10 estimate of Milk AA was not advantageous when compared with Milk MP , likely because AA use efficiency for milk was constant whereas MP use was variable. Future work evaluating variable AA use efficiencies for milk production is likely to improve accuracy and precision of models of allowable milk. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Discordance between patient and physician assessments of global disease activity in rheumatoid arthritis and association with work productivity.

    PubMed

    Smolen, Josef S; Strand, Vibeke; Koenig, Andrew S; Szumski, Annette; Kotak, Sameer; Jones, Thomas V

    2016-05-21

    Discordance between patient and physician ratings of rheumatoid arthritis (RA) severity occurs in clinical practice and correlates with pain scores and measurements of joint disease. However, information is lacking on whether discordance impacts patients' ability to work. We evaluated the discordance between patient and physician ratings of RA disease activity before and after treatment with etanercept and investigated the associations between discordance, clinical outcomes, and work productivity. In the PRESERVE clinical trial, patients with moderate RA received open-label etanercept 50 mg once weekly plus methotrexate for 36 weeks. Baseline and week-36 disease characteristics and clinical and work productivity outcomes were categorized according to week-36 concordance category, defined as positive discordance (patient global assessment - physician global assessment ≥2), negative discordance (patient global assessment - physician global assessment ≤ -2), and concordance (absolute difference between the two disease activity assessments = 0 or 1). Correlations between discordance, clinical outcomes, and predictors of discordance were determined. At baseline, 520/762 (68.2 %) patient and physician global assessment scores were concordant, 194 (25.5 %) were positively discordant, and 48 (6.3 %) were negatively discordant. After 36 weeks of therapy, 556/763 (72.9 %) scores were concordant, 189 (24.8 %) were positively discordant, and 18 (2.4 %) were negatively discordant. Patients with week-36 concordance had the best 36-week clinical and patient-reported outcomes, and overall, the greatest improvement between baseline and week 36. Baseline pain, swollen joint count, duration of morning stiffness, fatigue, and patient general health significantly correlated with week-36 discordance, p < 0.0001 to p < 0.05. Additionally, baseline pain, patient general health, and C-reactive protein were predictors of week-36 discordance (odds ratios 1.22, 1.02, and 0.98, respectively). For the employed patients, percent impairment while working and percent overall work impairment were highest (greatest impairment) at baseline and 36 weeks in the group with positive discordance. The percentage of patients with concordance increased after 36 weeks of treatment with etanercept, with concordant patients demonstrating the greatest improvement in clinical and patient-reported outcomes. Discordance correlated with several measures of disease activity and was associated with decreased work productivity. ClinicalTrials.gov identifier: NCT00565409 . Registered 28/11/2007.

  10. Variability between Clarke's angle and Chippaux-Smirak index for the diagnosis of flat feet

    PubMed Central

    Gonzalez-Martin, Cristina; Seoane-Pillado, Teresa; Lopez-Calviño, Beatriz; Pertega-Diaz, Sonia; Gil-Guillen, Vicente

    2017-01-01

    Abstract Background: The measurements used in diagnosing biomechanical pathologies vary greatly. The aim of this study was to determine the concordance between Clarke's angle and Chippaux-Smirak index, and to determine the validity of Clarke's angle using the Chippaux-Smirak index as a reference. Methods: Observational study in a random population sample (n= 1,002) in A Coruña (Spain). After informed patient consent and ethical review approval, a study was conducted of anthropometric variables, Charlson comorbidity score, and podiatric examination (Clarke's angle and Chippaux-Smirak index). Descriptive analysis and multivariate logistic regression were performed. Results: The prevalence of flat feet, using a podoscope, was 19.0% for the left foot and 18.9% for the right foot, increasing with age. The prevalence of flat feet according to the Chippaux-Smirak index or Clarke's angle increases significantly, reaching 62.0% and 29.7% respectively. The concordance (kappa I) between the indices according to age groups varied between 0.25-0.33 (left foot) and 0.21-0.30 (right foot). The intraclass correlation coefficient (ICC) between the Chippaux-Smirak index and Clarke's angle was -0.445 (left foot) and -0.424 (right foot). After adjusting for age, body mass index (BMI), comorbidity score and gender, the only variable with an independent effect to predict discordance was the BMI (OR= 0.969; 95% CI: 0.940-0.998). Conclusion: There is little concordance between the indices studied for the purpose of diagnosing foot arch pathologies. In turn, Clarke's angle has a limited sensitivity in diagnosing flat feet, using the Chippaux-Smirak index as a reference. This discordance decreases with higher BMI values. PMID:28559643

  11. Variability between Clarke's angle and Chippaux-Smirak index for the diagnosis of flat feet.

    PubMed

    Gonzalez-Martin, Cristina; Pita-Fernandez, Salvador; Seoane-Pillado, Teresa; Lopez-Calviño, Beatriz; Pertega-Diaz, Sonia; Gil-Guillen, Vicente

    2017-03-30

    The measurements used in diagnosing biomechanical pathologies vary greatly. The aim of this study was to determine the concordance between Clarke's angle and Chippaux-Smirak index, and to determine the validity of Clarke's angle using the Chippaux-Smirak index as a reference. Observational study in a random population sample (n= 1,002) in A Coruña (Spain). After informed patient consent and ethical review approval, a study was conducted of anthropometric variables, Charlson comorbidity score, and podiatric examination (Clarke's angle and Chippaux-Smirak index). Descriptive analysis and multivariate logistic regression were performed. The prevalence of flat feet, using a podoscope, was 19.0% for the left foot and 18.9% for the right foot, increasing with age. The prevalence of flat feet according to the Chippaux-Smirak index or Clarke's angle increases significantly, reaching 62.0% and 29.7% respectively. The concordance (kappa I) between the indices according to age groups varied between 0.25-0.33 (left foot) and 0.21-0.30 (right foot). The intraclass correlation coefficient (ICC) between the Chippaux-Smirak index and Clarke's angle was -0.445 (left foot) and -0.424 (right foot). After adjusting for age, body mass index (BMI), comorbidity score and gender, the only variable with an independent effect to predict discordance was the BMI (OR= 0.969; 95% CI: 0.940-0.998). There is little concordance between the indices studied for the purpose of diagnosing foot arch pathologies. In turn, Clarke's angle has a limited sensitivity in diagnosing flat feet, using the Chippaux-Smirak index as a reference. This discordance decreases with higher BMI values.

  12. [Validation of a questionnaire to assess the quality of health information in Argentinian newspapers].

    PubMed

    Biondo, Emiliano; Khoury, Marina Claudia

    2005-09-01

    The daily press is an important source of health information and may influence health care utilization. However, medical reports published in newspapers from developed countries have shown a poor quality. The reliability of the questionnaire Index of Scientific Quality was evaluated by using it to measure the scientific quality of health information published by Argentinian newspapers between 2000 and 2002. It assessed the readability of the texts in grade levels and explored the relationship between quality and other factors. The Spanish adaptation of the instrument consisted in translation, back-traslation and pilot study. The reliability was assessed by applying the instrument to newspaper articles with more than 300 words that discussed therapy, diagnosis, prevention, lifestyle effects, and hazardous exposure. Two physicians independently graded 129 articles. Inter-observer and intra-observer concordance was quantified for each item with the intra-class correlation coefficient (CI95%). To measure scientific quality, a randomized sample of 210 articles was assessed. Each received a mark that ranged from 0 to 100. Readability was determined by the FRY graph method. The relationship between quality and other variables was explored with multiple linear regression analysis. The inter-rater concordance varied between 0.48 (0.34-0.61) and 0.67 (0.56-0.75). Intra-rater concordance varied from 0.51 (0.37-0.63) to 0.95 (0.93-0.96). The internal consistency (Cronbach's alpha) was 0.88. The quality-of-health-information was rated at 25 points (16.7, 33.3) [median (intercuartil range)]. The reading level was assessed to be at the 10.4 grade (10.2-10.6) [mean (CI 95%)]. Quality of the health information was greatly deficient; however, no specific factors were related with quality. Readability was probably a key barrier for access to the health information.

  13. A European benchmarking system to evaluate in-hospital mortality rates in acute coronary syndrome: the EURHOBOP project.

    PubMed

    Dégano, Irene R; Subirana, Isaac; Torre, Marina; Grau, María; Vila, Joan; Fusco, Danilo; Kirchberger, Inge; Ferrières, Jean; Malmivaara, Antti; Azevedo, Ana; Meisinger, Christa; Bongard, Vanina; Farmakis, Dimitros; Davoli, Marina; Häkkinen, Unto; Araújo, Carla; Lekakis, John; Elosua, Roberto; Marrugat, Jaume

    2015-03-01

    Hospital performance models in acute myocardial infarction (AMI) are useful to assess patient management. While models are available for individual countries, mainly US, cross-European performance models are lacking. Thus, we aimed to develop a system to benchmark European hospitals in AMI and percutaneous coronary intervention (PCI), based on predicted in-hospital mortality. We used the EURopean HOspital Benchmarking by Outcomes in ACS Processes (EURHOBOP) cohort to develop the models, which included 11,631 AMI patients and 8276 acute coronary syndrome (ACS) patients who underwent PCI. Models were validated with a cohort of 55,955 European ACS patients. Multilevel logistic regression was used to predict in-hospital mortality in European hospitals for AMI and PCI. Administrative and clinical models were constructed with patient- and hospital-level covariates, as well as hospital- and country-based random effects. Internal cross-validation and external validation showed good discrimination at the patient level and good calibration at the hospital level, based on the C-index (0.736-0.819) and the concordance correlation coefficient (55.4%-80.3%). Mortality ratios (MRs) showed excellent concordance between administrative and clinical models (97.5% for AMI and 91.6% for PCI). Exclusion of transfers and hospital stays ≤1day did not affect in-hospital mortality prediction in sensitivity analyses, as shown by MR concordance (80.9%-85.4%). Models were used to develop a benchmarking system to compare in-hospital mortality rates of European hospitals with similar characteristics. The developed system, based on the EURHOBOP models, is a simple and reliable tool to compare in-hospital mortality rates between European hospitals in AMI and PCI. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

    PubMed

    van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel

    2018-02-01

    To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.

  15. Genetic Traits in the Liver Anatomy Between Parents and Children: An Analysis of Liver Transplant Recipients and Living Donors.

    PubMed

    Jeong, M J; Hwang, S; Song, G W; Jung, D H; Ha, T Y; Park, G C; Alshahrani, A A; Kirchner, V A; Beduschi, T; Lee, S G

    2016-01-01

    To date, no significant similarities in the anatomy of the hepatic vasculature have been observed between blood-related individuals. However, we have frequently encountered anatomic similarities between parents and their children; thus, we performed an analysis of the genetic traits in the anatomy of the liver. The study cohort was 330 adult cases of living-donor liver transplantation (LDLT), in which the donor-recipient relationship was child to parent. The subjects underwent LDLT from January 2013 to December 2014. Preoperative dynamic computerized tomographic scans were used to classify the anatomy of the hepatic vasculature. Portal vein (PV) anatomy was classified as typical and 2 variant types. PV anatomy combinations in donor and recipient were typical in 232 subjects, variant in 16, and typical-variant in 82. The PV concordance rate was 75.2%, and the contingency coefficient was 0.130 (P = .017). Hepatic artery (HA) anatomy was classified as typical and 4 variant types. HA anatomy combinations in donor and recipient were typical in 167 subjects, variant in 33, and typical-variant in 130. The HA concordance rate was 60.6%, and the contingency coefficient was 0.058 (P = .294). The sizable inferior right hepatic vein in donor and recipient was present in 44 subjects, absent in 160, and discordant in 126; its concordance rate was 61.8% and contingency coefficient 0.133 (P = .014). There may be a shared but weak genetic trait between parents and children regarding the anatomy of the PV and inferior hepatic vein. This information may be helpful when LDLT is performed between 1st-degree relatives. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Can Alberta infant motor scale and milani comparetti motor development screening test be rapid alternatives to bayley scales of infant development-II at high-risk infants

    PubMed Central

    Yıldırım, Zeynep Hoşbay; Aydınlı, Nur; Ekici, Barış; Tatlı, Burak; Çalişkan, Mine

    2012-01-01

    Purpose: The main object of the present study is to assess neuromotor development of high-risk infants by using three tests, and to determine inter-test concordance and the feasibility of these tests. Materials and Methods: One-hundred and nine patients aged between 0 and 6 months and identified as “high-risk infant” according to the Kliegman's criteria were enrolled to the study. Three different tests were used to assess neuromotor development of the patients: Bayley scales of infant development-II (BSID-II), Alberta infant motor scale (AIMS), and Milani Comparetti Motor Development Screening Test (MCMDST). Results: Correlation analysis was performed between pure scores of BSID-II motor scale and total scores of AIMS. These two tests were highly correlated (r:0.92). Moderate concordance was found between BSID-II and AIMS (k:0.35). Slight concordance was found between BSID-II and MCMDST; and the concordance was slight again for AIMS and MCMDST (k:0.11 and k:0.16, respectively) too. Conclusion: AIMS has a high correlation and consistency with BSID-II and can be used with routine neurological examination as it is based on observations, has few items, and requires less time to complete. PMID:22919192

  17. Can Alberta infant motor scale and milani comparetti motor development screening test be rapid alternatives to bayley scales of infant development-II at high-risk infants.

    PubMed

    Yıldırım, Zeynep Hoşbay; Aydınlı, Nur; Ekici, Barış; Tatlı, Burak; Calişkan, Mine

    2012-07-01

    The main object of the present study is to assess neuromotor development of high-risk infants by using three tests, and to determine inter-test concordance and the feasibility of these tests. One-hundred and nine patients aged between 0 and 6 months and identified as "high-risk infant" according to the Kliegman's criteria were enrolled to the study. Three different tests were used to assess neuromotor development of the patients: Bayley scales of infant development-II (BSID-II), Alberta infant motor scale (AIMS), and Milani Comparetti Motor Development Screening Test (MCMDST). Correlation analysis was performed between pure scores of BSID-II motor scale and total scores of AIMS. These two tests were highly correlated (r:0.92). Moderate concordance was found between BSID-II and AIMS (k:0.35). Slight concordance was found between BSID-II and MCMDST; and the concordance was slight again for AIMS and MCMDST (k:0.11 and k:0.16, respectively) too. AIMS has a high correlation and consistency with BSID-II and can be used with routine neurological examination as it is based on observations, has few items, and requires less time to complete.

  18. Comparison of the King’s and MiToS staging systems for ALS

    PubMed Central

    Fang, Ton; Al Khleifat, Ahmad; Stahl, Daniel R; Lazo La Torre, Claudia; Murphy, Caroline; Young, Carolyn; Shaw, Pamela J; Leigh, P Nigel; Al-Chalabi, Ammar

    2017-01-01

    Abstract Objective: To investigate and compare two ALS staging systems, King’s clinical staging and Milano-Torino (MiToS) functional staging, using data from the LiCALS phase III clinical trial (EudraCT 2008-006891-31). Methods: Disease stage was derived retrospectively for each system from the ALS Functional Rating Scale-Revised subscores using standard methods. The two staging methods were then compared for timing of stages using box plots, correspondence using chi-square tests, agreement using a linearly weighted kappa coefficient and concordance using Spearman’s rank correlation. Results: For both systems, progressively higher stages occurred at progressively later proportions of the disease course, but the distribution differed between the two methods. King’s stage 3 corresponded to MiToS stage 1 most frequently, with earlier King’s stages 1 and 2 largely corresponding to MiToS stage 0 or 1. The Spearman correlation was 0.54. There was fair agreement between the two systems with kappa coefficient of 0.21. Conclusion: The distribution of timings shows that the two systems are complementary, with King’s staging showing greatest resolution in early to mid-disease corresponding to clinical or disease burden, and MiToS staging having higher resolution for late disease, corresponding to functional involvement. We therefore propose using both staging systems when describing ALS. PMID:28054828

  19. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population

    PubMed Central

    González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida

    2018-01-01

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance. PMID:29690618

  20. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population.

    PubMed

    Bernal-Orozco, María Fernanda; Badillo-Camacho, Nayeli; Macedo-Ojeda, Gabriela; González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida; Vizmanos, Barbara

    2018-04-23

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April⁻August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  1. The efficacy of the Microsoft KinectTM to assess human bimanual coordination.

    PubMed

    Liddy, Joshua J; Zelaznik, Howard N; Huber, Jessica E; Rietdyk, Shirley; Claxton, Laura J; Samuel, Arjmand; Haddad, Jeffrey M

    2017-06-01

    The Microsoft Kinect has been used in studies examining posture and gait. Despite the advantages of portability and low cost, this device has not been used to assess interlimb coordination. Fundamental insights into movement control, variability, health, and functional status can be gained by examining coordination patterns. In this study, we investigated the efficacy of the Microsoft Kinect to capture bimanual coordination relative to a research-grade motion capture system. Twenty-four healthy adults performed coordinated hand movements in two patterns (in-phase and antiphase) at eight movement frequencies (1.00-3.33 Hz). Continuous relative phase (CRP) and discrete relative phase (DRP) were used to quantify the means (mCRP and mDRP) and variability (sdCRP and sdDRP) of coordination patterns. Between-device agreement was assessed using Bland-Altman bias with 95 % limits of agreement, concordance correlation coefficients (absolute agreement), and Pearson correlation coefficients (relative agreement). Modest-to-excellent relative and absolute agreements were found for mCRP in all conditions. However, mDRP showed poor agreement for the in-phase pattern at low frequencies, due to large between-device differences in a subset of participants. By contrast, poor absolute agreement was observed for both sdCRP and sdDRP, while relative agreement ranged from poor to excellent. Overall, the Kinect captures the macroscopic patterns of bimanual coordination better than coordination variability.

  2. Continuous quantitative measurement of the proximal airway dimensions and lung density on four-dimensional dynamic-ventilation CT in smokers

    PubMed Central

    Yamashiro, Tsuneo; Moriya, Hiroshi; Tsubakimoto, Maho; Matsuoka, Shin; Murayama, Sadayuki

    2016-01-01

    Purpose Four-dimensional dynamic-ventilation computed tomography (CT) imaging demonstrates continuous movement of the airways and lungs, which cannot be depicted with conventional CT. We aimed to investigate continuous changes in lung density and airway dimensions and to assess the correlation with spirometric values in smokers. Materials and methods This retrospective study was approved by the Institutional Review Board, and informed consent was waived. Twenty-one smokers including six patients with COPD underwent four-dimensional dynamic-ventilation CT during free breathing (160 mm in length). The mean lung density (MLD) of the scanned lung and luminal areas (Ai) of fixed points in the trachea and the right proximal bronchi (main bronchus, upper bronchus, bronchus intermedius, and lower bronchus) were continuously measured. Concordance between the time curve of the MLD and that of the airway Ai values was expressed by cross-correlation coefficients. The associations between these quantitative measurements and the forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) values were assessed by Spearman’s rank correlation analysis. Results On the time curve for the MLD, the Δ-MLD1.05 values between the peak inspiratory frame to the later third frame (1.05 seconds later) were strongly correlated with the FEV1/FVC (ρ=0.76, P<0.0001). The cross-correlation coefficients between the airway Ai and MLD values were significantly correlated with the FEV1/FVC (ρ=−0.56 to −0.66, P<0.01), except for the right upper bronchus. This suggested that the synchrony between the airway and lung movement was lost in patients with severe airflow limitation. Conclusion Respiratory changes in the MLD and synchrony between the airway Ai and the MLD measured with dynamic-ventilation CT were correlated with patient’s spirometric values. PMID:27110108

  3. Is Needle Biopsy Clinically Useful in Preoperative Grading of Central Chondrosarcoma of the Pelvis and Long Bones?

    PubMed

    Roitman, Pablo D; Farfalli, Germán L; Ayerza, Miguel A; Múscolo, D Luis; Milano, Federico E; Aponte-Tinao, Luis A

    2017-03-01

    Central chondrosarcoma of bone is graded on a scale of 1 to 3 according to histological criteria. Clinically, these tumors can be divided into low-grade (Grade 1) and high-grade (Grade 2, Grade 3, and dedifferentiated) chondrosarcomas. Although en bloc resection has been the most widely used treatment, it has become generally accepted that in selected patients with low-grade chondrosarcomas of long bones, curettage is safe and effective. This approach requires an accurate preoperative estimation of grade to avoid under- or overtreatment, but prior reports have indicated that both imaging and biopsy do not always give an accurate prediction of grade. (1) What is the concordance of image-guided needle preoperative biopsy and postoperative grading in central (intramedullary) chondrosarcomas of long bones, and how does this compare with the concordance of image-guided needle preoperative biopsy and postoperative grading in central pelvic chondrosarcomas? (2) What is the concordance of preoperative image-guided needle biopsy and postoperative findings in differentiating low-grade from high-grade central chondrosarcomas of long bones, and how does this compare with the concordance in central pelvic chondrosarcomas? Between 1997 and 2014, in our institution, we treated 126 patients for central chondrosarcomas located in long bones and the pelvis. Of these 126 cases, 41 were located in the pelvis and the remaining 85 cases were located in long bones. This study considers 39 (95%) and 40 (47%) of them, respectively. We included all cases in which histological information was complete regarding preoperative and postoperative tumor grading. We excluded all cases with incomplete data sets or nondiagnostic preoperative biopsies. To evaluate the needle biopsy accuracy, we compared the histological tumor grade, obtained from the preoperative biopsy, with the final histological grade obtained from the postoperative surgical specimen. The weighted and nonweighted kappa statistics were used to evaluate the agreement. Concordance between the preoperative biopsy and the final pathological analysis in terms of histological grade was much higher in long-bone chondrosarcoma than in pelvic chondrosarcoma (83% [33 of 40] versus 36% [14 of 39]; odds ratio, 8, 48). Likewise, the weighted kappa coefficients were higher in long-bone chondrosarcoma than in pelvic chondrosarcoma for the determination of histological grade (0.63; 95% confidence interval [CI], 0.34-0.91 versus 0.12; -0.32 to 0.57; p < 0.001). When categorizing the lesions as low grade or high grade, concordance between the preoperative biopsy and the final pathological analysis was much higher in long-bone chondrosarcoma than in pelvic chondrosarcoma (90% [36 of 40] versus 67% [26 of 39]; odds ratio, 4, 5). Likewise, the weighted kappa coefficients were higher in long-bone chondrosarcoma than in pelvic chondrosarcoma (0.73; 95% CI, 0.51-0.94 versus 0.26; 0.04-0.48; p < 0.001). Image-guided needle biopsy, when performed by a specialist radiologist and evaluated by an experienced bone pathologist, is a useful tool in determining the histological grade of long-bone chondrosarcomas allowing identification of true low-grade tumors. The histological grade should be correlated with imaging and the clinical presentation, but under these circumstances, experienced tumor surgeons may use this information in planning surgical treatment. The same appears not to be true for pelvic lesions, in which histological grade established by needle biopsy should be interpreted with caution. Level III, diagnostic study.

  4. Evaluation of various equations for estimating renal function in elderly Chinese patients with type 2 diabetes mellitus

    PubMed Central

    Guo, Mei; Niu, Jian-Ying; Ye, Xian-Wu; Han, Xiao-Jie; Zha, Ying; Hong, Yang; Fang, Hong; Gu, Yong

    2017-01-01

    Background The clinical assessment of kidney function based on the estimated glomerular filtration rate (GFR) in older patients remains controversial. This study evaluated the concordance and feasibility of using various creatinine-based equations for estimating GFR in elderly Chinese patients with type 2 diabetes mellitus (T2DM). Methods A cross-sectional analytical study was conducted in 21,723 older diabetic patients (≥60 years) based on electronic health records (EHR) for Minhang District, Shanghai, China. The concordance of chronic kidney disease (CKD) classification among different creatinine-based equations was assessed based on Kappa values, intraclass correlation coefficient (ICC) statistics, and the eGFR agreement between the equations was tested using Bland–Altman plots. The GFR was estimated using the Cockcroft–Gault (CG), Berlin Initiative Study 1 (BIS1), simplified Modification of Diet in Renal Disease (MDRD), MDRD modified for Chinese populations (mMDRD), chronic kidney disease epidemiology collaboration (CKD-EPI), CKD-EPI in Asians (CKD-EPI-Asia), and Ruijin equations. Results Overall, the proportion of CKD stages 3–5 (eGFR <60 mL/min/1.73 m2) was calculated as 28.9%, 39.1%, 11.8%, 8.4%, 14.3%, 11.5%, and 12.7% by the eGFRCG, eGFRBIS1, eGFRMDRD, eGFRmMDRD, eGFRCKD-EPI, eGFRCKD-EPI-Asia, and eGFRRuijin equations, respectively. The concordance of albuminuria and decreased eGFR based on the different equations was poor by both the Kappa (<0.2) and ICC (<0.4) statistics. The CKD-EPI-Asia equation resulted in excellent concordance with the CKD-EPI (ICC =0.931), MDRD (ICC =0.963), mMDRD (ICC =0.892), and Ruijin (ICC =0.956) equations for the classification of CKD stages, whereas the BIS1 equation exhibited good concordance with the CG equation (ICC =0.809). In addition, significant differences were observed for CKD stage 1 among all these equations. Conclusion Accurate GFR values are difficult to estimate using creatinine-based equations in older diabetic patients. Kidney function is complex, and the staff need to be aware of the individualized consideration of other risk factors or markers of reduced renal function in clinical practice. PMID:29070944

  5. Applying Amide Proton Transfer MR Imaging to Hybrid Brain PET/MR: Concordance with Gadolinium Enhancement and Added Value to [18F]FDG PET.

    PubMed

    Sun, Hongzan; Xin, Jun; Zhou, Jinyuan; Lu, Zaiming; Guo, Qiyong

    2018-06-01

    The purpose of this study is to evaluate the diagnostic concordance and metric correlations of amide proton transfer (APT) imaging with gadolinium-enhanced magnetic resonance imaging (MRI) and 2-deoxy-2-[ 18 F-]fluoro-D-glucose ([ 18 F]FDG) positron emission tomography (PET), using hybrid brain PET/MRI. Twenty-one subjects underwent brain gadolinium-enhanced [ 18 F]FDG PET/MRI prospectively. Imaging accuracy was compared between unenhanced MRI, MRI with enhancement, APT-weighted (APTW) images, and PET based on six diagnostic criteria. Among tumors, the McNemar test was further used for concordance assessment between gadolinium-enhanced imaging, APT imaging, and [ 18 F]FDG PET. As well, the relation of metrics between APT imaging and PET was analyzed by the Pearson correlation analysis. APT imaging and gadolinium-enhanced MRI showed superior and similar diagnostic accuracy. APTW signal intensity and gadolinium enhancement were concordant in 19 tumors (100 %), while high [ 18 F]FDG avidity was shown in only 12 (63.2 %). For the metrics from APT imaging and PET, there was significant correlation for 13 hypermetabolic tumors (P < 0.05) and no correlation for the remaining six [ 18 F]FDG-avid tumors. APT imaging can be used to increase diagnostic accuracy with no need to administer gadolinium chelates. APT imaging may provide an added value to [ 18 F]FDG PET in the evaluation of tumor metabolic activity during brain PET/MR studies.

  6. Automated Grading System for Evaluation of Superficial Punctate Keratitis Associated With Dry Eye.

    PubMed

    Rodriguez, John D; Lane, Keith J; Ousler, George W; Angjeli, Endri; Smith, Lisa M; Abelson, Mark B

    2015-04-01

    To develop an automated method of grading fluorescein staining that accurately reproduces the clinical grading system currently in use. From the slit lamp photograph of the fluorescein-stained cornea, the region of interest was selected and punctate dot number calculated using software developed with the OpenCV computer vision library. Images (n = 229) were then divided into six incremental severity categories based on computed scores. The final selection of 54 photographs represented the full range of scores: nine images from each of six categories. These were then evaluated by three investigators using a clinical 0 to 4 corneal staining scale. Pearson correlations were calculated to compare investigator scores, and mean investigator and automated scores. Lin's Concordance Correlation Coefficients (CCC) and Bland-Altman plots were used to assess agreement between methods and between investigators. Pearson's correlation between investigators was 0.914; mean CCC between investigators was 0.882. Bland-Altman analysis indicated that scores assessed by investigator 3 were significantly higher than those of investigators 1 and 2 (paired t-test). The predicted grade was calculated to be: Gpred = 1.48log(Ndots) - 0.206. The two-point Pearson's correlation coefficient between the methods was 0.927 (P < 0.0001). The CCC between predicted automated score Gpred and mean investigator score was 0.929, 95% confidence interval (0.884-0.957). Bland-Altman analysis did not indicate bias. The difference in SD between clinical and automated methods was 0.398. An objective, automated analysis of corneal staining provides a quality assurance tool to be used to substantiate clinical grading of key corneal staining endpoints in multicentered clinical trials of dry eye.

  7. Effect of ergonomics training on agreement between expert and nonexpert ratings of the potential for musculoskeletal harm in manufacturing tasks.

    PubMed

    Fethke, Nathan B; Merlino, Linda; Gerr, Fred

    2013-12-01

    To evaluate the effect of ergonomics training on non-ergonomists' ability to recognize and characterize the potential for musculoskeletal harm in manufacturing tasks. Ergonomics training was delivered to members of a participatory ergonomics team in a manufacturing facility. Before and after training, participatory ergonomics team members and the research team rated the potential for musculoskeletal harm for each of 30 tasks. Measures of agreement included Pearson, concordance, and intraclass correlation coefficients. Measures of agreement generally improved after training. The greatest agreement was observed for ratings of the potential for musculoskeletal harm to the low back. The greatest improvement in agreement was observed for ratings of the potential for musculoskeletal harm to the neck/shoulder. The training seemed to improve non-experts' ability to identify the potential for musculoskeletal harm.

  8. Performance of a quality assurance program for assessing dental health in methamphetamine users.

    PubMed

    Dye, Bruce A; Harrell, Lauren; Murphy, Debra A; Belin, Thomas; Shetty, Vivek

    2015-07-05

    Systematic characterization of the dental consequences of methamphetamine (MA) abuse presupposes a rigorous quality assurance (QA) program to ensure the credibility of the data collected and the scientific integrity and validity of the clinical study. In this report we describe and evaluate the performance of a quality assurance program implemented in a large cross-sectional study of the dental consequences of MA use. A large community sample of MA users was recruited over a 30 month period during 2011-13 and received comprehensive oral examinations and psychosocial assessments by site examiners based at two large community health centers in Los Angeles. National Health and Nutrition Examination Survey (NHANES) protocols for oral health assessments were utilized to characterize dental disease. Using NHANES oral health quality assurance guidelines, examiner reliability statistics such as Cohen's Kappa coefficients and inter-class correlation coefficients were calculated to assess the magnitude of agreement between the site examiners and a reference examiner to ensure conformance and comparability with NHANES practices. Approximately 9% (n = 49) of the enrolled 574 MA users received a repeat dental caries and periodontal examination conducted by the reference examiner. There was high concordance between the reference examiner and the site examiners for identification of untreated dental disease (Kappa statistic values: 0.57-0.75, percent agreement 83-88%). For identification of untreated caries on at least 5 surfaces of anterior teeth, the Kappas ranged from 0.77 to 0.87, and percent agreement from 94 to 97%. The intra-class coefficients (ICCs) ranged from 0.87 to 89 for attachment loss across all periodontal sites assessed and the ICCs ranged from 0.79 to 0.81 for pocket depth. For overall gingival recession, the ICCs ranged from 0.88 to 0.91. When Kappa was calculated based on the CDC/AAP case definitions for severe periodontitis, inter-examiner reliability for site examiners was low (Kappa 0.27-0.67). Overall, the quality assurance program confirmed the procedural adherence of the quality of the data collected on the distribution of dental caries and periodontal disease in MA-users. Examiner concordance was higher for dental caries but lower for specific periodontal assessments.

  9. Magnetic resonance imaging-transectal ultrasound image-fusion biopsies accurately characterize the index tumor: correlation with step-sectioned radical prostatectomy specimens in 135 patients.

    PubMed

    Baco, Eduard; Ukimura, Osamu; Rud, Erik; Vlatkovic, Ljiljana; Svindland, Aud; Aron, Manju; Palmer, Suzanne; Matsugasumi, Toru; Marien, Arnaud; Bernhard, Jean-Christophe; Rewcastle, John C; Eggesbø, Heidi B; Gill, Inderbir S

    2015-04-01

    Prostate biopsies targeted by elastic fusion of magnetic resonance (MR) and three-dimensional (3D) transrectal ultrasound (TRUS) images may allow accurate identification of the index tumor (IT), defined as the lesion with the highest Gleason score or the largest volume or extraprostatic extension. To determine the accuracy of MR-TRUS image-fusion biopsy in characterizing ITs, as confirmed by correlation with step-sectioned radical prostatectomy (RP) specimens. Retrospective analysis of 135 consecutive patients who sequentially underwent pre-biopsy MR, MR-TRUS image-fusion biopsy, and robotic RP at two centers between January 2010 and September 2013. Image-guided biopsies of MR-suspected IT lesions were performed with tracking via real-time 3D TRUS. The largest geographically distinct cancer focus (IT lesion) was independently registered on step-sectioned RP specimens. A validated schema comprising 27 regions of interest was used to identify the IT center location on MR images and in RP specimens, as well as the location of the midpoint of the biopsy trajectory, and variables were correlated. The concordance between IT location on biopsy and RP specimens was 95% (128/135). The coefficient for correlation between IT volume on MRI and histology was r=0.663 (p<0.001). The maximum cancer core length on biopsy was weakly correlated with RP tumor volume (r=0.466, p<0.001). The concordance of primary Gleason pattern between targeted biopsy and RP specimens was 90% (115/128; κ=0.76). The study limitations include retrospective evaluation of a selected patient population, which limits the generalizability of the results. Use of MR-TRUS image fusion to guide prostate biopsies reliably identified the location and primary Gleason pattern of the IT lesion in >90% of patients, but showed limited ability to predict cancer volume, as confirmed by step-sectioned RP specimens. Biopsies targeted using magnetic resonance images combined with real-time three-dimensional transrectal ultrasound allowed us to reliably identify the spatial location of the most important tumor in prostate cancer and characterize its aggressiveness. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  10. The Sedentary Time and Activity Reporting Questionnaire (STAR-Q): Reliability and Validity Against Doubly Labeled Water and 7-Day Activity Diaries

    PubMed Central

    Csizmadi, Ilona; Neilson, Heather K.; Kopciuk, Karen A.; Khandwala, Farah; Liu, Andrew; Friedenreich, Christine M.; Yasui, Yutaka; Rabasa-Lhoret, Rémi; Bryant, Heather E.; Lau, David C. W.; Robson, Paula J.

    2014-01-01

    We determined measurement properties of the Sedentary Time and Activity Reporting Questionnaire (STAR-Q), which was designed to estimate past-month activity energy expenditure (AEE). STAR-Q validity and reliability were assessed in 102 adults in Alberta, Canada (2009–2011), who completed 14-day doubly labeled water (DLW) protocols, 7-day activity diaries on day 15, and the STAR-Q on day 14 and again at 3 and 6 months. Three-month reliability was substantial for total energy expenditure (TEE) and AEE (intraclass correlation coefficients of 0.84 and 0.73, respectively), while 6-month reliability was moderate. STAR-Q-derived TEE and AEE were moderately correlated with DLW estimates (Spearman's ρs of 0.53 and 0.40, respectively; P < 0.001), and on average, the STAR-Q overestimated TEE and AEE (median differences were 367 kcal/day and 293 kcal/day, respectively). Body mass index-, age-, sex-, and season-adjusted concordance correlation coefficients (CCCs) were 0.24 (95% confidence interval (CI): 0.07, 0.36) and 0.21 (95% CI: 0.11, 0.32) for STAR-Q-derived versus DLW-derived TEE and AEE, respectively. Agreement between the diaries and STAR-Q (metabolic equivalent-hours/day) was strongest for occupational sedentary time (adjusted CCC = 0.76, 95% CI: 0.64, 0.85) and overall strenuous activity (adjusted CCC = 0.64, 95% CI: 0.49, 0.76). The STAR-Q demonstrated substantial validity for estimating occupational sedentary time and strenuous activity and fair validity for ranking individuals by AEE. PMID:25038920

  11. A novel iris transillumination grading scale allowing flexible assessment with quantitative image analysis and visual matching.

    PubMed

    Wang, Chen; Brancusi, Flavia; Valivullah, Zaheer M; Anderson, Michael G; Cunningham, Denise; Hedberg-Buenz, Adam; Power, Bradley; Simeonov, Dimitre; Gahl, William A; Zein, Wadih M; Adams, David R; Brooks, Brian

    2018-01-01

    To develop a sensitive scale of iris transillumination suitable for clinical and research use, with the capability of either quantitative analysis or visual matching of images. Iris transillumination photographic images were used from 70 study subjects with ocular or oculocutaneous albinism. Subjects represented a broad range of ocular pigmentation. A subset of images was subjected to image analysis and ranking by both expert and nonexpert reviewers. Quantitative ordering of images was compared with ordering by visual inspection. Images were binned to establish an 8-point scale. Ranking consistency was evaluated using the Kendall rank correlation coefficient (Kendall's tau). Visual ranking results were assessed using Kendall's coefficient of concordance (Kendall's W) analysis. There was a high degree of correlation among the image analysis, expert-based and non-expert-based image rankings. Pairwise comparisons of the quantitative ranking with each reviewer generated an average Kendall's tau of 0.83 ± 0.04 (SD). Inter-rater correlation was also high with Kendall's W of 0.96, 0.95, and 0.95 for nonexpert, expert, and all reviewers, respectively. The current standard for assessing iris transillumination is expert assessment of clinical exam findings. We adapted an image-analysis technique to generate quantitative transillumination values. Quantitative ranking was shown to be highly similar to a ranking produced by both expert and nonexpert reviewers. This finding suggests that the image characteristics used to quantify iris transillumination do not require expert interpretation. Inter-rater rankings were also highly similar, suggesting that varied methods of transillumination ranking are robust in terms of producing reproducible results.

  12. Comparison of ultrasound imaging in transverse median and parasagittal oblique planes for thoracic epidurals: A pilot study.

    PubMed

    Khemka, Rakhi; Rastogi, Sonal; Desai, Neha; Chakraborty, Arunangshu; Sinha, Subir

    2016-06-01

    The use of ultrasound (US) scanning to assess the depth of epidural space to prevent neurological complications is established in current practice. In this study, we hypothesised that pre-puncture US scanning for estimating the depth of epidural space for thoracic epidurals is comparable between transverse median (TM) and paramedian sagittal oblique (PSO) planes. We performed pre-puncture US scanning in 32 patients, posted for open abdominal surgeries. The imaging was done to detect the depth of epidural space from skin (ultrasound depth [UD]) and needle insertion point, in parasagittal oblique plane in PSO group and transverse median plane in TM group. Subsequently, epidural space was localised through the predetermined insertion point by 'loss of resistance' technique and needle depth (ND) to the epidural space was marked. Correlation between the UD and actual ND was calculated and concordance correlation coefficient (CCC) was used to determine the degree of agreement between UD and ND in both the planes. The primary outcome, i.e., the comparison between UD and ND, done using Pearson correlation coefficient, was 0.99 in both PSO and TM groups, and the CCC was 0.93 (95% confidence interval [95% CI]: 0.81-0.97) and 0.90 (95% CI: 0.74-0.96) in PSO and TM groups respectively, which shows a strong positive association between UD and ND in both groups. The use of pre-puncture US scanning in both PSO and TM planes for estimating the depth of epidural space at the level of mid- and lower-thoracic spine is comparable.

  13. Immunohistochemical detection of MTAP and BAP1 protein loss for mesothelioma diagnosis: Comparison with 9p21 FISH and BAP1 immunohistochemistry.

    PubMed

    Hida, Tomoyuki; Hamasaki, Makoto; Matsumoto, Shinji; Sato, Ayuko; Tsujimura, Tohru; Kawahara, Kunimitsu; Iwasaki, Akinori; Okamoto, Tatsuro; Oda, Yoshinao; Honda, Hiroshi; Nabeshima, Kazuki

    2017-02-01

    Differentiating malignant pleural mesothelioma (MPM) from reactive mesothelial hyperplasia (RMH) is still challenging. Detection of homozygous deletion (HD) of 9p21 region including p16 INK4A (p16) by fluorescence in situ hybridization (FISH) and immunohistochemical detection of loss of BRCA1 associated protein 1 (BAP1), are reliable markers for MPM diagnosis. However, not all laboratories are equipped to perform 9p21 FISH; immunohistochemistry (IHC) is a more common and feasible technique. Thus, we sought to develop a IHC-based method that could predict the deletion of p16 in MPM in concordance with 9p21 FISH. We examined the expression of the 9p21.3-related proteins (p14, p15, p16, and methylthioadenosine phosphorylase (MTAP)) and BAP1 using IHC in 51 MPM and 25 RMH cases, and assessed their correlation with HD of p16 detected by FISH. The diagnostic usefulness of IHC of the 9p21.3-related proteins and BAP1 and their combinations was assessed using the cut-off values set by receiver operating characteristic (ROC) analysis. Among the 9p21.3-related proteins, MTAP IHC findings showed best concordance with 9p21 FISH results (kappa coefficient of 0.69) and a specificity of 100%. We also examined the combinations of MTAP IHC with the other products. The loss of p16 and MTAP had better concordance (kappa coefficient of 0.71), although lower specificity (85%). For differentiating MPM from RMH, only MTAP showed 100% specificity among the 9p21.3-related proteins, as did BAP1 IHC and 9p21 FISH. Among BAP1 combinations, only that of BAP1 with MTAP showed 100% specificity. Its sensitivity was 76.5%, which was lower than BAP1 IHC and 9p21 FISH combination (84.3%), but higher than BAP1 IHC alone (60.8%) or 9p21 FISH alone (60.8%). A combination of MTAP or BAP1 loss detected by IHC can likely detect MPM with good sensitivity and 100% specificity, and serve as useful ancillary IHC for discriminating MPM from RMH. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Development and validation of anthropometric equations to estimate appendicular muscle mass in elderly women.

    PubMed

    Pereira, Piettra Moura Galvão; da Silva, Giselma Alcântara; Santos, Gilberto Moreira; Petroski, Edio Luiz; Geraldes, Amandio Aristides Rihan

    2013-07-02

    This study aimed to examine the cross validity of two anthropometric equations commonly used and propose simple anthropometric equations to estimate appendicular muscle mass (AMM) in elderly women. Among 234 physically active and functionally independent elderly women, 101 (60 to 89 years) were selected through simple drawing to compose the study sample. The paired t test and the Pearson correlation coefficient were used to perform cross-validation and concordance was verified by intraclass correction coefficient (ICC) and by the Bland and Altman technique. To propose predictive models, multiple linear regression analysis, anthropometric measures of body mass (BM), height, girth, skinfolds, body mass index (BMI) were used, and muscle perimeters were included in the analysis as independent variables. Dual-Energy X-ray Absorptiometry (AMMDXA) was used as criterion measurement. The sample power calculations were carried out by Post Hoc Compute Achieved Power. Sample power values from 0.88 to 0.91 were observed. When compared, the two equations tested differed significantly from the AMMDXA (p <0.001 and p = 0.001). Ten population / specific anthropometric equations were developed to estimate AMM, among them, three equations achieved all validation criteria used: AMM (E2) = 4.150 +0.251 [bodymass (BM)] - 0.411 [bodymass index (BMI)] + 0.011 [Right forearm perimeter (PANTd) 2]; AMM (E3) = 4.087 + 0.255 (BM) - 0.371 (BMI) + 0.011 (PANTd) 2 - 0.035 [thigh skinfold (DCCO)]; MMA (E6) = 2.855 + 0.298 (BM) + 0.019 (Age) - 0,082 [hip circumference (PQUAD)] + 0.400 (PANTd) - 0.332 (BMI). The equations estimated the criterion method (p = 0.056 p = 0.158), and explained from 0.69% to 0.74% of variations observed in AMMDXA with low standard errors of the estimate (1.36 to 1.55 kg) and high concordance (ICC between 0,90 and 0.91 and concordance limits from -2,93 to 2,33 kg). The equations tested were not valid for use in physically active and functionally independent elderly women. The simple anthropometric equations developed in this study showed good practical applicability and high validity to estimate AMM in elderly women.

  15. Development and validation of anthropometric equations to estimate appendicular muscle mass in elderly women

    PubMed Central

    2013-01-01

    Objective This study aimed to examine the cross validity of two anthropometric equations commonly used and propose simple anthropometric equations to estimate appendicular muscle mass (AMM) in elderly women. Methods Among 234 physically active and functionally independent elderly women, 101 (60 to 89 years) were selected through simple drawing to compose the study sample. The paired t test and the Pearson correlation coefficient were used to perform cross-validation and concordance was verified by intraclass correction coefficient (ICC) and by the Bland and Altman technique. To propose predictive models, multiple linear regression analysis, anthropometric measures of body mass (BM), height, girth, skinfolds, body mass index (BMI) were used, and muscle perimeters were included in the analysis as independent variables. Dual-Energy X-ray Absorptiometry (AMMDXA) was used as criterion measurement. The sample power calculations were carried out by Post Hoc Compute Achieved Power. Sample power values from 0.88 to 0.91 were observed. Results When compared, the two equations tested differed significantly from the AMMDXA (p <0.001 and p = 0.001). Ten population / specific anthropometric equations were developed to estimate AMM, among them, three equations achieved all validation criteria used: AMM (E2) = 4.150 +0.251 [bodymass (BM)] - 0.411 [bodymass index (BMI)] + 0.011 [Right forearm perimeter (PANTd) 2]; AMM (E3) = 4.087 + 0.255 (BM) - 0.371 (BMI) + 0.011 (PANTd) 2 - 0.035 [thigh skinfold (DCCO)]; MMA (E6) = 2.855 + 0.298 (BM) + 0.019 (Age) - 0,082 [hip circumference (PQUAD)] + 0.400 (PANTd) - 0.332 (BMI). The equations estimated the criterion method (p = 0.056 p = 0.158), and explained from 0.69% to 0.74% of variations observed in AMMDXA with low standard errors of the estimate (1.36 to 1.55 kg) and high concordance (ICC between 0,90 and 0.91 and concordance limits from -2,93 to 2,33 kg). Conclusion The equations tested were not valid for use in physically active and functionally independent elderly women. The simple anthropometric equations developed in this study showed good practical applicability and high validity to estimate AMM in elderly women. PMID:23815948

  16. Enumeration of Escherichia coli in swab samples from pre- and post-chilled pork and lamb carcasses using 3M™ Petrifilm™ Select E. coli and Simplate® Coliforms/E. coli.

    PubMed

    Hauge, Sigrun J; Østensvik, Øyvin; Monshaugen, Marte; Røtterud, Ole-Johan; Nesbakken, Truls; Alvseike, Ole

    2017-08-01

    The aim of the study was to compare two analytical methods; 3M Petrifilm™ Select E. coli and SimPlate® Coliforms &E. coli, for detection and enumeration of E. coli using swab samples from naturally contaminated pork and lamb carcasses that were collected before and after chilling. Blast chilling was used for pork carcasses. Swab samples (n=180) were collected from 60 warm and 60 chilled pork carcasses, and 30 warm and 30 chilled lamb carcasses, and analysed in parallel. The concordance correlation coefficient between Petrifilm and SimPlate was 0.89 for pork and 0.81 for lamb carcasses. However, the correlation was higher for warm carcasses (0.90) than chilled carcasses (0.72). For chilled lamb carcasses, the correlation was only 0.50, and SimPlate gave slightly higher results than Petrifilm (P=0.09). Slower chilling gave slightly lesser agreement between methods than for blast chilling, however, both Petrifilm and SimPlate methodologies are suitable and recommended for use in small laboratories in abattoirs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Genotype-Specific Concordance of Chlamydia trachomatis Genital Infection Within Heterosexual Partnerships.

    PubMed

    Schillinger, Julia A; Katz, Barry P; Markowitz, Lauri E; Braslins, Phillip G; Shrier, Lydia A; Madico, Guillermo; Van Der Pol, Barbara; Orr, Donald P; Rice, Peter A; Batteiger, Byron E

    2016-12-01

    Sexual transmission rates of Chlamydia trachomatis (Ct) cannot be measured directly; however, the study of concordance of Ct infection in sexual partnerships (dyads) can help to illuminate factors influencing Ct transmission. Heterosexual men and women with Ct infection and their sex partners were enrolled and partner-specific coital and behavioral data collected for the prior 30 days. Microbiological data included Ct culture, and nucleic acid amplification testing (NAAT), quantitative Ct polymerase chain reaction, and ompA genotyping. We measured Ct concordance in dyads and factors (correlates) associated with concordance. One hundred twenty-one women and 125 men formed 128 dyads. Overall, 72.9% of male partners of NAAT-positive women and 68.6% of female partners of NAAT-positive men were Ct-infected. Concordance was more common in dyads with culture-positive members (78.6% of male partners, 77% of female partners). Partners of women and men who were NAAT-positive only had lower concordance (33.3%, 46.4%, respectively). Women in concordant dyads had significantly higher median endocervical quantitative Ct polymerase chain reaction values (3,032) compared with CT-infected women in discordant dyads (1013 inclusion forming units DNA equivalents per mL; P < 0.01). Among 54 Ct-concordant dyads with ompA genotype data for both members, 96.2% had identical genotypes. Higher organism load appears associated with concordance among women. Same-genotype chlamydial concordance was high in sexual partnerships. No behavioral factors were sufficiently discriminating to guide partner services activities. Findings may help model coitus-specific transmission probabilities.

  18. Psychometric validation of the behavioral indicators of pain scale for the assessment of pain in mechanically ventilated and unable to self-report critical care patients.

    PubMed

    Latorre-Marco, I; Acevedo-Nuevo, M; Solís-Muñoz, M; Hernández-Sánchez, L; López-López, C; Sánchez-Sánchez, M M; Wojtysiak-Wojcicka, M; de Las Pozas-Abril, J; Robleda-Font, G; Frade-Mera, M J; De Blas-García, R; Górgolas-Ortiz, C; De la Figuera-Bayón, J; Cavia-García, C

    2016-11-01

    To assess the psychometric properties of the behavioral indicators of pain scale (ESCID) when applied to a wide range of medical and surgical critical patients. A multicentre, prospective observational study was designed to validate a scale measuring instrument. Twenty Intensive Care Units of 14 hospitals belonging to the Spanish National Health System. A total of 286 mechanically ventilated, unable to self-report critically ill medical and surgical adult patients. Pain levels were measured by two independent evaluators simultaneously, using two scales: ESCID and the behavioral pain scale (BPS). Pain was observed before, during, and after two painful procedures (turning, tracheal suctioning) and one non-painful procedure. ESCID reliability was measured on the basis of internal consistency using the Cronbach-α coefficient. Inter-rater and intra-rater agreement were measured. The Spearman correlation coefficient was used to assess the correlation between ESCID and BPS. A total of 4386 observations were made in 286 patients (62% medical and 38% surgical). High correlation was found between ESCID and BPS (r=0.94-0.99; p<0.001), together with high intra-rater and inter-rater concordance. ESCID was internally reliable, with a Cronbach-α value of 0.85 (95%CI 0.81-0.88). Cronbach-α coefficients for ESCID domains were high: facial expression 0.87 (95%CI 0.84-0.89), calmness 0.84 (95%CI 0.81-0.87), muscle tone 0.80 (95%CI 0.75-0.84), compliance with mechanical ventilation 0.70 (95%CI 0.63-0.75) and consolability 0.85 (95%CI 0.81-0.88). ESCID is valid and reliable for measuring pain in mechanically ventilated unable to self-report medical and surgical critical care patients. CLINICALTRIALS.GOV: NCT01744717. Copyright © 2016 The Authors. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Advantages of RNA-seq compared to RNA microarrays for transcriptome profiling of anterior cruciate ligament tears.

    PubMed

    Rai, Muhammad Farooq; Tycksen, Eric D; Sandell, Linda J; Brophy, Robert H

    2018-01-01

    Microarrays and RNA-seq are at the forefront of high throughput transcriptome analyses. Since these methodologies are based on different principles, there are concerns about the concordance of data between the two techniques. The concordance of RNA-seq and microarrays for genome-wide analysis of differential gene expression has not been rigorously assessed in clinically derived ligament tissues. To demonstrate the concordance between RNA-seq and microarrays and to assess potential benefits of RNA-seq over microarrays, we assessed differences in transcript expression in anterior cruciate ligament (ACL) tissues based on time-from-injury. ACL remnants were collected from patients with an ACL tear at the time of ACL reconstruction. RNA prepared from torn ACL remnants was subjected to Agilent microarrays (N = 24) and RNA-seq (N = 8). The correlation of biological replicates in RNA-seq and microarrays data was similar (0.98 vs. 0.97), demonstrating that each platform has high internal reproducibility. Correlations between the RNA-seq data and the individual microarrays were low, but correlations between the RNA-seq values and the geometric mean of the microarrays values were moderate. The cross-platform concordance for differentially expressed transcripts or enriched pathways was linearly correlated (r = 0.64). RNA-Seq was superior in detecting low abundance transcripts and differentiating biologically critical isoforms. Additional independent validation of transcript expression was undertaken using microfluidic PCR for selected genes. PCR data showed 100% concordance (in expression pattern) with RNA-seq and microarrays data. These findings demonstrate that RNA-seq has advantages over microarrays for transcriptome profiling of ligament tissues when available and affordable. Furthermore, these findings are likely transferable to other musculoskeletal tissues where tissue collection is challenging and cells are in low abundance. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:484-497, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Cross-cultural adaptation, reliability, and validity of the Turkish version of PedsQL 3.0 Arthritis Module: a quality-of-life measure for patients with juvenile idiopathic arthritis in Turkey.

    PubMed

    Tarakci, E; Baydogan, S N; Kasapcopur, O; Dirican, A

    2013-04-01

    The aim of this study was to describe the cultural adaptation, validity, and reliability of a Turkish version of the pediatric quality-of-life inventory (PedsQL) 3.0 Arthritis Module in a population with juvenile idiopathic arthritis (JIA). A total of 169 patients with JIA and their parents were enrolled in the study. The Turkish version of the childhood health assessment questionnaire (CHAQ) was used to evaluate the validity of related domains in the PedsQL 3.0 Arthritis Module. Both the PedsQL 3.0 Arthritis Module and CHAQ were filled out by children over 8 years of age and by the parents of children 2-7 years of age. Internal reliability was poor to excellent (Cronbach's alpha coefficients 0.56-0.84 for self-reporting and 0.63-0.82 for parent reporting), and interobserver reliability varied from good to excellent (intraclass correlation coefficient (ICC) 0.79-0.91 for self-reporting and 0.80-0.88 for parent reporting) for the total scores of the PedsQL 3.0 Arthritis Module. Parent-child concordance for all scores was moderate to excellent (ICC 0.42-0.92). The PedsQL 3.0 Arthritis Module and CHAQ were highly positively correlated, with coefficients from 0.21 to 0.76, indicating concurrent validity. We demonstrated the reliability and validity of quality-of-life measurement using the Turkish version of the PedsQL 3.0 Arthritis Module in our sociocultural context. The PedsQL 3.0 Arthritis Module can be utilized as a tool for the evaluation of quality of life in patients with JIA aged 2-18 years.

  1. Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial.

    PubMed

    Zehnder, Pascal; Roth, Beat; Burkhard, Fiona C; Kessler, Thomas M

    2008-09-01

    We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

  2. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer chemotherapy.

    PubMed

    Lee, Clara N; Wetschler, Matthew H; Chang, Yuchiao; Belkora, Jeffrey K; Moy, Beverly; Partridge, Ann; Sepucha, Karen R

    2014-08-20

    Women diagnosed with early stage (I or II) breast cancer face a highly challenging decision - whether or not to undergo adjuvant chemotherapy. We developed a decision quality instrument for chemotherapy for early stage breast cancer and sought to evaluate its performance. Cross-sectional, mailed survey of recent breast cancer survivors, providers, and healthy controls and a retest survey of survivors. The decision quality instrument includes questions on knowledge and personal goals. It results in a knowledge score and concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, validity, and reliability of the survey instrument were examined. Responses were received from 352 patients, 89 providers and 35 healthy controls. The decision quality instrument was feasible to implement with few missing data. The knowledge scores had good retest reliability (intraclass correlation coefficient (ICC) =0.75). Knowledge scores discriminated between providers and patients (mean difference 31.1%, 95% CI 26.9, 35.3) and between patients and healthy controls (mean difference 11.2, 95% CI 5.4, 17.1). Most providers reported that the knowledge items covered essential content. Two of the five goal items had a ceiling effect, and one goal had low content validity. The goal items had moderate retest reliability (ICC's 0.57 to 0.78). In the multivariable model of treatment, none of the patient goals was associated with receipt of chemotherapy. Age and hormone receptor status were the only variables independently associated with chemotherapy. Most patients (77.6%) had treatment concordant with that predicted by the model. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. The Decision Quality Instrument is a reliable and valid measure of patient knowledge about chemotherapy, but its ability to measure concordance with patient goals is limited. In this sample, patient goals were not associated with treatment, and most patients reported they were not asked their preference, suggesting that goals were not adequately considered in decision making.

  3. Reliability and Validity of 2 Self-Report Measures to Assess Sedentary Behavior in Older Adults.

    PubMed

    Gennuso, Keith P; Matthews, Charles E; Colbert, Lisa H

    2015-05-01

    The purpose of this study was to examine the reliability and validity of 2 currently available physical activity surveys for assessing time spent in sedentary behavior (SB) in older adults. Fifty-eight adults (≥65 years) completed the Yale Physical Activity Survey for Older Adults (YPAS) and Community Health Activities Model Program for Seniors (CHAMPS) before and after a 10-day period during which they wore an ActiGraph accelerometer (ACC). Intraclass correlation coefficients (ICC) examined test-retest reliability. Overall percent agreement and a kappa statistic examined YPAS validity. Lin's concordance correlation, Pearson correlation, and Bland-Altman analysis examined CHAMPS validity. Both surveys had moderate test-retest reliability (ICC: YPAS = 0.59 (P < .001), CHAMPS = 0.64 (P < .001)) and significantly underestimated SB time. Agreement between YPAS and ACC was low (κ = -0.0003); however, there was a linear increase (P < .01) in ACC-derived SB time across YPAS response categories. There was poor agreement between ACC-derived SB and CHAMPS (Lin's r = .005; 95% CI, -0.010 to 0.020), and no linear trend across CHAMPS quartiles (P = .53). Neither of the surveys should be used as the sole measure of SB in a study; though the YPAS has the ability to rank individuals, providing it with some merit for use in correlational SB research.

  4. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    PubMed

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  5. Validation of a semi-quantitative food frequency questionnaire to assess food groups and nutrient intake.

    PubMed

    Macedo-Ojeda, Gabriela; Vizmanos-Lamotte, Barbara; Márquez-Sandoval, Yolanda Fabiola; Rodríguez-Rocha, Norma Patricia; López-Uriarte, Patricia Josefina; Fernández-Ballart, Joan D

    2013-11-01

    Semi-quantitative Food Frequency Questionnaires (FFQs) analyze average food and nutrient intake over extended periods to associate habitual dietary intake with health problems and chronic diseases. A tool of this nature applicable to both women and men is not presently available in Mexico. To validate a FFQ for adult men and women. The study was conducted on 97 participants, 61% were women. Two FFQs were administered (with a one-year interval) to measure reproducibility. To assess validity, the second FFQ was compared against dietary record (DR) covering nine days. Statistical analyses included Pearson correlations and Intraclass Correlation Coefficients (ICC). The de-attenuation of the ICC resulting from intraindividual variability was controlled. The validity analysis was complemented by comparing the classification ability of FFQ to that of DR through concordance between intake categories and Bland-Altman plots. Reproducibility: ICC values for food groups ranged 0.42-0.87; the range for energy and nutrients was between 0.34 and 0.82. ICC values for food groups ranged 0.35-0.84; the range for energy and nutrients was between 0.36 and 0.77. Most subjects (56.7-76.3%) classified in the same or adjacent quintile for energy and nutrients using both methods. Extreme misclassification was <6.3% for all items. Bland-Altman plots reveal high concordance between FFQ and DR. FFQ produced sufficient levels of reproducibility and validity to determine average daily intake over one year. These results will enable the analysis of possible associations with chronic diseases and dietary diagnoses in adult populations of men and women. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  6. Comparison of Three Different Sensitive Assays for Hepatitis B Virus DNA in Monitoring of Responses to Antiviral Therapy

    PubMed Central

    Chan, Henry L. Y.; Leung, Nancy W. Y.; Lau, Tracy C. M.; Wong, May L.; Sung, Joseph J. Y.

    2000-01-01

    The aim of our study was to compare the performances of two new hepatitis B virus (HBV) DNA assays, a cross-linking assay (NAXCOR) and a hybrid-capture amplification assay (Digene), versus the widely used branched-DNA (bDNA) assay (Chiron) in the monitoring of HBV DNA levels during antiviral treatment. Serial serum samples from 12 chronically HBV infected patients undergoing a phase II trial of an antiviral drug, 2′,3′-dideoxy-5-fluoro-3′-thiacytidine (FTC), were studied. A total of 96 serum samples were tested for HBV DNA using the cross-linking, hybrid-capture amplification, and bDNA assays. In the comparison of the cross-linking and bDNA assays, concordant results were found in 77 (80.3%) samples, no significant difference was found between the median log10 HBV DNA levels (6.66 versus 7.17 meq/ml), and the results of the two assays were closely correlated (r = 0.95). In the comparison of the hybrid-capture amplification and bDNA assays, concordant results were found in 79 (82.3%) samples, no significant difference was found between the median log10 HBV DNA levels (6.98 versus 6.99 meq/ml), and the results of the two assays were closely correlated (r = 0.99). Six (6.3%) samples by the cross-linking assay and 10 (10.4%) samples by the bDNA assay required retesting because of unacceptably high within-run coefficients of variance. No sample required retesting in the hybrid-capture amplification assay according to the internal validation. In conclusion, the cross-linking and hybrid-capture amplification assays were as sensitive as the bDNA assay for HBV DNA detection and can be recommended for monitoring of HBV DNA levels during antiviral treatment. PMID:10970358

  7. [Evaluation of the nutritional status of children under 5 years of age: concordance between anthropometric indices in the indigenous population of Chiapas (Mexico)].

    PubMed

    Ochoa-Díaz López, Héctor; García-Parra, Esmeralda; Flores-Guillén, Elena; García-Miranda, Rosario; Solís-Hernández, Roberto

    2017-07-28

    Nutritional status is determined through various methods, including anthropometry. In children under 5 years of age indeces as weight/age (w/a), height/age (h/a), weight/height (w/h) and body mass index (BMI) are used. The purpose of this article is to analyze and compare the ability of different anthropometric indeces to identify children from marginalized communities in Chiapas (Mexico) with nutritional problems. To analyze the correlation among the different anthropometric indeces to determine the nutritional status of children under 5 years of age in poor rural areas with a background of short stature. Cross-sectional study in 1,160 children under 5 years of age in 13 high poverty communities in three regions of Chiapas. The variables studied were age, sex, weight and height. Nutritional status was determined through the indeces w/a, h/a, w/h and BMI. Field staff in charge of taking measurements of weight and height were trained and standardized. Kappa coefficients for agreement between the indeces were calculated. No correlation between BMI and w/a and h/a was found. The prevalence of malnutrition according to h/a was 64.8%. Only high concordance (0.726) between BMI and w/h was found. BMI showed a low prevalence of malnutrition and a higher prevalence of overweight and obesity rates. For a reliable and accurate diagnosis in individuals with a background of chronic malnutrition, it is recommended to use the four indeces together. Doing so it will reduce the risk of underestimating or overestimating nutritional status and will focus actions toward addressing and improving the health and nutrition of children living under extreme poverty conditions.

  8. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    PubMed

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86

  9. Validity and reliability of the Fitbit Zip as a measure of preschool children’s step count

    PubMed Central

    Sharp, Catherine A; Mackintosh, Kelly A; Erjavec, Mihela; Pascoe, Duncan M; Horne, Pauline J

    2017-01-01

    Objectives Validation of physical activity measurement tools is essential to determine the relationship between physical activity and health in preschool children, but research to date has not focused on this priority. The aims of this study were to ascertain inter-rater reliability of observer step count, and interdevice reliability and validity of Fitbit Zip accelerometer step counts in preschool children. Methods Fifty-six children aged 3–4 years (29 girls) recruited from 10 nurseries in North Wales, UK, wore two Fitbit Zip accelerometers while performing a timed walking task in their childcare settings. Accelerometers were worn in secure pockets inside a custom-made tabard. Video recordings enabled two observers to independently code the number of steps performed in 3 min by each child during the walking task. Intraclass correlations (ICCs), concordance correlation coefficients, Bland-Altman plots and absolute per cent error were calculated to assess the reliability and validity of the consumer-grade device. Results An excellent ICC was found between the two observer codings (ICC=1.00) and the two Fitbit Zips (ICC=0.91). Concordance between the Fitbit Zips and observer counts was also high (r=0.77), with an acceptable absolute per cent error (6%–7%). Bland-Altman analyses identified a bias for Fitbit 1 of 22.8±19.1 steps with limits of agreement between −14.7 and 60.2 steps, and a bias for Fitbit 2 of 25.2±23.2 steps with limits of agreement between −20.2 and 70.5 steps. Conclusions Fitbit Zip accelerometers are a reliable and valid method of recording preschool children’s step count in a childcare setting. PMID:29081984

  10. Double match of 18F-fluorodeoxyglucose-PET and iomazenil-SPECT improves outcomes of focus resection surgery.

    PubMed

    Fujimoto, Ayataka; Okanishi, Tohru; Kanai, Sotaro; Sato, Keishiro; Itamura, Shinji; Baba, Shimpei; Nishimura, Mitsuyo; Masui, Takayuki; Enoki, Hideo

    2018-06-01

    When the results of electroencephalography (EEG), magnetic resonance imaging (MRI), and seizure semiology are discordant or no structural lesion is evident on MRI, single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are important examinations for lateralization or localization of epileptic regions. We hypothesized that the concordance between interictal 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 FDG)-PET and iomazenil (IMZ)-SPECT could suggest the epileptogenic lobe in patients with non-lesional findings on MRI. Fifty-nine patients (31 females, 28 males; mean age, 29 years; median age, 27 years; range, 7-56 years) underwent subdural electrode implantation followed by focus resection. All patients underwent 18 FDG-PET, IMZ-SPECT, and focus resection surgery. Follow-up was continued for ≥ 2 years. We evaluated surgical outcomes as seizure-free or not and analyzed correlations between outcomes and concordances of low-uptake lobes on PET, SPECT, or both PET and SPECT to the resection lobes. We used uni- and multivariate logistic regression analyses. In univariate analyses, all three concordances correlated significantly with seizure-free outcomes (PET, p = 0.017; SPECT, p = 0.030; both PET and SPECT, p = 0.006). In multivariate analysis, concordance between resection and low-uptake lobes in both PET and SPECT correlated significantly with seizure-free outcomes (p = 0.004). The odds ratio was 6.0. Concordance between interictal 18 FDG-PET and IMZ-SPECT suggested that the epileptogenic lobe is six times better than each examination alone among patients with non-lesional findings on MRI. IMZ-SPECT and 18 FDG-PET are complementary examinations in the assessment of localization-related epilepsy.

  11. Evaluation of an antigen-capture EIA for the diagnosis of hepatitis E virus infection.

    PubMed

    Zhao, C; Geng, Y; Harrison, T J; Huang, W; Song, A; Wang, Y

    2015-11-01

    An enzyme immunoassay (EIA) has been developed for hepatitis E virus (HEV) antigen (HEV-Ag) detection and marketed in China. This study aimed to evaluate the sensitivity of the assay and assess the value of HEV-Ag detection in the diagnosis of HEV infection in comparison with HEV RNA detection. Using serial dilutions of a genotype 4 HEV strain, significant correlation was found between the EIA (S/CO) and HEV RNA (IU/mL) concentration in the range 10(3.5) to 10(0.5) IU/mL HEV RNA, the Pearson correlation coefficient r approached 0.97. The EIA detection limit was 54.6 IU/mL, compared to 24 IU/mL for HEV RNA using real-time RT-PCR. In clinical samples from hepatitis E patients, the HEV-Ag and HEV RNA positivity rates were 55.6% (65/117) and 60.7% (71/117) in sera and 76.7% (56/73) and 84.9% (62/73) in stools, and the concordance of these two markers was 77.8% in sera and 80.8% in stools. In serum samples, the HEV-Ag positivity rate and the concordance between HEV-Ag and HEV RNA were inversely proportional to the presence of anti-HEV antibody. The presence of anti-HEV IgG could reduce the S/CO of the HEV-Ag EIA. These results reveal a significant correlation between the detection of HEV-Ag and HEV RNA. The sensitivity of the HEV-Ag EIA was lower than real-time RT-PCR but could be higher than conventional nested RT-PCR. Therefore, the detection of HEV-Ag in serum and faeces is valuable for the diagnosis and prognosis of HEV infection in developing regions where real-time RT-PCR is not available. © 2015 John Wiley & Sons Ltd.

  12. Micro-scale Spatial Clustering of Cholera Risk Factors in Urban Bangladesh.

    PubMed

    Bi, Qifang; Azman, Andrew S; Satter, Syed Moinuddin; Khan, Azharul Islam; Ahmed, Dilruba; Riaj, Altaf Ahmed; Gurley, Emily S; Lessler, Justin

    2016-02-01

    Close interpersonal contact likely drives spatial clustering of cases of cholera and diarrhea, but spatial clustering of risk factors may also drive this pattern. Few studies have focused specifically on how exposures for disease cluster at small spatial scales. Improving our understanding of the micro-scale clustering of risk factors for cholera may help to target interventions and power studies with cluster designs. We selected sets of spatially matched households (matched-sets) near cholera case households between April and October 2013 in a cholera endemic urban neighborhood of Tongi Township in Bangladesh. We collected data on exposures to suspected cholera risk factors at the household and individual level. We used intra-class correlation coefficients (ICCs) to characterize clustering of exposures within matched-sets and households, and assessed if clustering depended on the geographical extent of the matched-sets. Clustering over larger spatial scales was explored by assessing the relationship between matched-sets. We also explored whether different exposures tended to appear together in individuals, households, and matched-sets. Household level exposures, including: drinking municipal supplied water (ICC = 0.97, 95%CI = 0.96, 0.98), type of latrine (ICC = 0.88, 95%CI = 0.71, 1.00), and intermittent access to drinking water (ICC = 0.96, 95%CI = 0.87, 1.00) exhibited strong clustering within matched-sets. As the geographic extent of matched-sets increased, the concordance of exposures within matched-sets decreased. Concordance between matched-sets of exposures related to water supply was elevated at distances of up to approximately 400 meters. Household level hygiene practices were correlated with infrastructure shown to increase cholera risk. Co-occurrence of different individual level exposures appeared to mostly reflect the differing domestic roles of study participants. Strong spatial clustering of exposures at a small spatial scale in a cholera endemic population suggests a possible role for highly targeted interventions. Studies with cluster designs in areas with strong spatial clustering of exposures should increase sample size to account for the correlation of these exposures.

  13. Concordance of sexual dysfunction and dissatisfaction by self-report and those by partner's perception in young adult couples.

    PubMed

    Gungor, S; Keskin, U; Gülsün, M; Erdem, M; Ceyhan, S T; Ergün, A

    2015-07-01

    We evaluated concordance levels of young adult spouses (N=107 couples, total N=214) with regards to sexual satisfaction by using Golombock-Rust Inventory of Sexual Satisfaction (GRISS). Each spouse of the couples filled out both female and male forms of the GRISS. Self- and spouse-reported scores were analyzed in terms of inter-rater correlation and agreement. The prevalence of overall sexual dissatisfaction was 10.3% and 26.2% in wives and husbands, respectively. The correlation coefficient (r) between the self-reported overall sexual satisfaction scores and those assessed by the spouses was 0.25 (P=0.014) and 0.04 (P=0.680) for wives and husbands, respectively. The sensitivity for perception of partner's sexual problems ranged 11% to 47%, and the specificity was around 64% to 100%, except for vaginismus, which had a sensitivity of 83% and a specificity of 25%. The prevalance-adjusted and bias-adjusted kappa (PABAK) value for overall sexual dissatisfaction reported by themselves and that assessed by their spouses was 0.68 and 0.16 for the wives and husbands, respectively. For specific female sexual problems, the PABAK value was the highest in female dissatisfaction (0.81) followed by anorgasmia (0.78), female avoidance (0.44), vaginismus (0.44), infrequency (0.33), non-communication (0.14) and female nonsensuality (0.14). For specific male sexual problems, the PABAK value was the highest in male nonsensuality (1.00), followed by male dissatisfaction (0.78), infrequency (0.46), non-communication (0.42), male avoidance (0.36), impotence (0.27) and premature ejaculation (-0.04). Our findings suggested that in this clinical sample the partner's perception of sexual dysfunction and dissatisfaction did not correlate well with the subject's self-reported sexual problems, and generally male sexual problems were less correctly perceived by the partners than were female sexual problems. This result may provide helpful information for clinicians who take care of patients' sexual problems.

  14. Validity of self-measured waist and hip circumferences: results from a community study in Malaysia.

    PubMed

    Reidpath, Daniel D; Cheah, Julius Chee-Ho; Lam, Fui-Ching; Yasin, Shahjahan; Soyiri, Ireneous; Allotey, Pascale

    2013-10-05

    Measures of central adiposity are better predictors of adverse health events than BMI. Nonetheless, BMI is more widely used in health research. One reason for this may be the limited research supporting the self-measurement of waist and hip circumference. The lack of validity studies is particularly acute in Asia. The main objective was to establish the validity of self-measurement of waist and hip circumference in a community setting and the correlation of those measures with BMI, blood pressure, and blood glucose levels. A community based, cross-sectional survey. A "healthy living expo" at a shopping mall in a rural town on peninsular Malaysia One hundred and thirty six (136) individuals volunteered to participate in the study, 125 of whom met the inclusion criteria. The ethnic distribution of the participants was 80% Chinese, 17% Malay and 3% Indian. Most participants were female (60%), with participants' ages ranging from 18 to 78 years (mean, 47.2). Self and assisted measurements of waist and hip were taken. Blood pressure, non-fasting blood glucose, height, and weight were also measured. Bland Altman plots and Lin's concordance coefficient were used to measure agreement between self and assisted measures. Pearson's correlation was used to examine the association of self and assisted measures with blood pressure, blood glucose, and BMI. There was a downwards bias in self measured waist (-0.81 cm) and hip (-1 cm) circumferences compared with assisted measures. The concordance for the self and assisted measures of waist, hip and the ratio of the two were, respectively, .96, .93 , and .84. The correlation between measures of central adiposity and BMI, blood pressure and blood glucose were similar for self and assisted measures. The results provide additional support for the use of self-measurement of waist and hip circumference studies of central adiposity, but is limited by the specificity of the setting.

  15. Interrelationships among invasive and non-invasive indicators of biological maturation in adolescent male soccer players.

    PubMed

    Malina, Robert M; Coelho E Silva, Manuel J; Figueiredo, António J; Carling, Christopher; Beunen, Gaston P

    2012-01-01

    The relationships among indicators of biological maturation were evaluated and concordance between classifications of maturity status in two age groups of youth soccer players examined (11-12 years, n = 87; 13-14 years, n = 93). Data included chronological age (CA), skeletal age (SA, Fels method), stage of pubic hair, predicted age at peak height velocity, and percent of predicted adult height. Players were classified as on time, late or early in maturation using the SA-CA difference, predicted age at peak height velocity, and percent of predicted mature height. Factor analyses indicated two factors in players aged 11-12 years (maturity status: percent of predicted mature height, stage of pubic hair, 59% of variance; maturity timing: SA/CA ratio, predicted age at peak height velocity, 26% of variance), and one factor in players aged 13-14 years (68% of variance). Kappa coefficients were low (0.02-0.23) and indicated poor agreement between maturity classifications. Spearman rank-order correlations between categories were low to moderate (0.16-0.50). Although the indicators were related, concordance of maturity classifications between skeletal age and predicted age at peak height velocity and percent predicted mature height was poor. Talent development programmes call for the classification of youth as early, average, and late maturing for the purpose of designing training and competition programmes. Non-invasive indicators of maturity status have limitations for this purpose.

  16. Concordance of DSM-IV Axis I and II diagnoses by personal and informant's interview.

    PubMed

    Schneider, Barbara; Maurer, Konrad; Sargk, Dieter; Heiskel, Harald; Weber, Bernhard; Frölich, Lutz; Georgi, Klaus; Fritze, Jürgen; Seidler, Andreas

    2004-06-30

    The validity and reliability of using psychological autopsies to diagnose a psychiatric disorder is a critical issue. Therefore, interrater and test-retest reliability of the Structured Clinical Interview for DSM-IV Axis I and Personality Disorders and the usefulness of these instruments for the psychological autopsy method were investigated. Diagnoses by informant's interview were compared with diagnoses generated by a personal interview of 35 persons. Interrater reliability and test-retest reliability were assessed in 33 and 29 persons, respectively. Chi-square analysis, kappa and intraclass correlation coefficients, and Kendall's tau were used to determine agreement of diagnoses. Kappa coefficients were above 0.84 for substance-related disorders, mood disorders, and anxiety and adjustment disorders, and above 0.65 for Axis II disorders for interrater and test-retest reliability. Agreement by personal and relative's interview generated kappa coefficients above 0.79 for most Axis I and above 0.65 for most personality disorder diagnoses; Kendall's tau for dimensional individual personality disorder scores ranged from 0.22 to 0.72. Despite of a small number of psychiatric disorders in the selected population, the present results provide support for the validity of most diagnoses obtained through the best-estimate method using the Structured Clinical Interview for DSM-IV Axis I and Personality Disorders. This instrument can be recommended as a tool for the psychological autopsy procedure in post-mortem research. Copyright 2004 Elsevier Ireland Ltd.

  17. Objective Assessment of Isotretinoin-Associated Cheilitis: Isotretinoin Cheilitis Grading Scale

    PubMed Central

    Ornelas, Jennifer; Rosamilia, Lorraine; Larsen, Larissa; Foolad, Negar; Wang, Quinlu; Li, Chin-Shang; Sivamani, Raja K.

    2016-01-01

    Importance Isotretinoin remains an effective treatment for severe acne. Despite its effectiveness, it includes many side effects, of which cheilitis is the most common. Objective To develop an objective grading scale for assessment of isotretinoin-associated cheilitis, Design Cross-sectional clinical grading study. Setting UC Davis Dermatology clinic. Participants Subjects were older than 18 years old and actively treated with oral isotretinoin. Exposures Oral Isotretinoin. Main outcomes and Measures We developed an isotretinoin cheilitis grading scale (ICGS) incorporating the following four characteristics: erythema, scale/crust, fissures, and inflammation of the commissures. Three board-certified dermatologists independently graded photographs of the subjects. Results The Kendall’s coefficient of concordance (KCC) for the ICGS was 0.88 (p<0.0001). The Kendall’s coefficient was ≥ 0.72 (p<0.0001) for each of the four characteristics included in the grading scale. An image-based measurement for lip roughness statistically significantly correlated with the lip scale/crusting assessment (r = 0.52, p <0.05). Conclusion and Relevance The ICGS is reproducible and relatively simple to use. It can be incorporated as an objective tool to aid in the assessment of isotretinoin associated cheilitis. PMID:26395167

  18. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    PubMed

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p < .0001), but clinically relevant discrepancies were found in 13.3% of patients. IRMA-3, which claims to be standardized to CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  19. Smartphone Photography as a Tool to Measure Knee Range of Motion.

    PubMed

    Mica, Megan Conti; Wagner, Eric R; Shin, Alexander Y

    2018-01-01

    The objective of this study was to validate measuring knee range of motion (ROM) from smartphone photography. Thirty-two participants (64 knees) obtained smartphone photographs of knee flexion and extension. Surgeons obtained the same photographs and goniometric measurement of ROM. ROM was measured using Adobe Photoshop. Goniometer versus digital measurements, participant versus surgeon photographs, and interobserver measurements were analyzed. The average difference in goniometer and digital photograph measurements was 5°. The interclass correlation was .642(L) and .656(R). The Bland-Altman plots demonstrated that 29/32 digital measurements were within the 95% confidence interval (CI). Participants' versus researchers' photographs averaged a 2° difference. The interclass correlation was .924(L) and .91(R). Bland-Altman plots demonstrated that 31/32 measurements were within the 95% CI. Interobserver reliability averaged aROMdifference of 5°. The concordance coefficients were .647(L) and .723(R). Bland-Altman plots demonstrated that 30 of 32 digital measurements were within the 95% CI. Measuring knee ROM using smartphone digital photography is valid and reliable. (Journal of Surgical Orthopaedic Advances 27(1):52-57, 2018).

  20. Electronic and structural aspects of p450-mediated drug metabolism.

    PubMed

    Lewis, David F V; Ito, Yuko; Lake, Brian G

    2009-04-01

    From a consideration of first principles for enzymes kinetics, we have employed theoretical methods which enable one to analyse the kinetics of cytochrome P450-mediated reactions which have been based on the known physicochemical principles underlying the majority of chemical or enzymatic reactions. A comparison is made between the correlation equations produced from the QSAR analysis of experimental P450 reaction rate data and those obtained from first principles, where there appears to be a generally satisfactory concordance between the two procedures. In this respect, we have developed expressions based on standard reaction kinetics theory which incorporate the Eyring and Marcus relationships. The analysis of P450-catalyzed reaction rates is elaborated to encompass a treatment of metabolic clearance, and satisfactory correlations are obtained with literature values for both intrinsic clearance and whole body clearance in terms of compound lipophilicity derived from log P data, where P is the octanol/water partition coefficient. The importance of ionization potential as a factor in the overall catalytic turnover of P450-mediated reactions is noted, especially in combination with the lipophilicity parameter, log P.

  1. Agreement between central corneal thickness measured using Pentacam, ultrasound pachymetry, specular microscopy and optic biometer Lenstar LS 900 and the influence of intraocular pressure.

    PubMed

    Borrego-Sanz, L; Sáenz-Francés, F; Bermudez-Vallecilla, M; Morales-Fernández, L; Martínez-de-la-Casa, J M; Santos-Bueso, E; Jañez, L; García-Feijoo, J

    2014-01-01

    To compare central corneal thickness (CCT) values obtained by Lenstar (LE), Pentacam (PC), specular microscopy (SM) and ultrasound pachymetry (UP) in healthy corneas and study their influence on intraocular pressure (IOP) readings determined by Goldmann applanation tonometry (GAT). CCT was measured in 76 healthy subjects by LE, PC, SM and UP. We established Lin's concordance correlation coefficient (ρ-C) between different techniques. The influence of CCT on GAT was established through univariate linear regression models, IOP being the dependent variable. The highest ρ-C was found between LE and SM at 0.94 (95% CI: 0.91-0.96) and between LE and UP at 0.95 (95% CI: 0.94-0.97). IOP readings showed less variability when CCT was determined using LE (7.7%, B = 0.16; 95% CI: 0.004-0.28). Although CCT values obtained with UP, PC, SM and LE show good correlation, these methods are not completely interchangeable. The amount of IOP variation differs when CCT is determined using LE or SM. © 2014 S. Karger AG, Basel.

  2. Individual characteristics, area social participation, and primary non-concordance with medication: a multilevel analysis.

    PubMed

    Johnell, Kristina; Lindström, Martin; Sundquist, Jan; Eriksson, Charli; Merlo, Juan

    2006-03-02

    Non-concordance with medication remains a major public health problem that imposes a considerable financial burden on the health care system, and there is still a need for studies on correlates of non-concordance. Our first aim is to analyse whether any of the individual characteristics age, educational level, financial strain, self-rated health, social participation, and trust in the health care system are associated with primary non-concordance with medication. Our second aim is to investigate whether people living in the same area have similar probability of primary non-concordance with medication, that relates to area social participation. We analysed cross sectional data from 9,070 women and 6,795 men aged 18 to 79 years, living in 78 areas in central Sweden, who participated in the Life & Health year 2000 survey, with multilevel logistic regression (individuals at the first level and areas at the second level). Younger age, financial strain, low self-rated health, and low trust in the health care system were associated with primary non-concordance with medication. However, area social participation was not related to primary non-concordance, and the variation in primary non-concordance between the areas was small. Our results indicate that people in central Sweden with younger age, financial difficulties, low self-rated health, and low trust in the health care system may have a higher probability of primary non-concordance with medication. However, the area of residence--as defined by administrative boundaries--seems to play a minor role for primary non-concordance.

  3. Individual characteristics, area social participation, and primary non-concordance with medication: a multilevel analysis

    PubMed Central

    Johnell, Kristina; Lindström, Martin; Sundquist, Jan; Eriksson, Charli; Merlo, Juan

    2006-01-01

    Background Non-concordance with medication remains a major public health problem that imposes a considerable financial burden on the health care system, and there is still a need for studies on correlates of non-concordance. Our first aim is to analyse whether any of the individual characteristics age, educational level, financial strain, self-rated health, social participation, and trust in the health care system are associated with primary non-concordance with medication. Our second aim is to investigate whether people living in the same area have similar probability of primary non-concordance with medication, that relates to area social participation. Methods We analysed cross sectional data from 9 070 women and 6 795 men aged 18 to 79 years, living in 78 areas in central Sweden, who participated in the Life & Health year 2000 survey, with multilevel logistic regression (individuals at the first level and areas at the second level). Results Younger age, financial strain, low self-rated health, and low trust in the health care system were associated with primary non-concordance with medication. However, area social participation was not related to primary non-concordance, and the variation in primary non-concordance between the areas was small. Conclusion Our results indicate that people in central Sweden with younger age, financial difficulties, low self-rated health, and low trust in the health care system may have a higher probability of primary non-concordance with medication. However, the area of residence – as defined by administrative boundaries – seems to play a minor role for primary non-concordance. PMID:16512907

  4. Automated measurement of 25-OH Vitamin D on the LUMIPULSE® G1200: analytical verification and method comparison.

    PubMed

    Parra, Marina; Foj, Laura; Filella, Xavier

    2016-07-01

    Because of its potential value in several pathologies, clinical interest in 25-hydroxy Vitamin D (25OH-D) is increasing. However, the standardisation of assays remains a significant problem. Our aim was to evaluate the performance of the novel Lumipulse G 25-OH Vitamin D assay (Fujirebio), comparing results with the Liaison (Diasorin) method. Analytical verification of the Lumipulse G 25-OH Vitamin D assay was performed. Both methods were compared using sera from 226 patients, including 111 patients with chronic renal failure (39 on haemodialysis) and 115 patients without renal failure. In addition, clinical concordance between assays was assessed. For Lumipulse G 25-OH Vitamin D assay, the limit of detection was 0.3 ng/mL, and the limit of quantification was 2.5 ng/mL with a 9.7% of coefficient of variation. Intra-and inter-assay coefficients of variation were <2.3 and <1.8% (25.4-50.0 ng/mL), respectively. Dilution linearity was in the range of 4.5-144.5 ng/mL. Method comparison resulted in a mean difference of -6.5% (95% CI from -8.8 to -4.1) for all samples between Liaison and Lumipulse G. Clinical concordance assessed by Kappa Index was 0.66. Lumipulse G 25-OH Vitamin D showed a good clinical concordance with the Liaison assay, although overall results measured in Lumipulse were higher by an average of 6.5%.

  5. Determining areas that require indoor insecticide spraying using Multi Criteria Evaluation, a decision-support tool for malaria vector control programmes in the Central Highlands of Madagascar

    PubMed Central

    Rakotomanana, Fanjasoa; Randremanana, Rindra V; Rabarijaona, Léon P; Duchemin, Jean Bernard; Ratovonjato, Jocelyn; Ariey, Frédéric; Rudant, Jean Paul; Jeanne, Isabelle

    2007-01-01

    Background The highlands of Madagascar present an unstable transmission pattern of malaria. The population has no immunity, and the central highlands have been the sites of epidemics with particularly high fatality. The most recent epidemic occurred in the 1980s, and caused about 30,000 deaths. The fight against malaria epidemics in the highlands has been based on indoor insecticide spraying to control malaria vectors. Any preventive programme involving generalised cover in the highlands will require very substantial logistical support. We used multicriteria evaluation, by the method of weighted linear combination, as basis for improved targeting of actions by determining priority zones for intervention. Results Image analysis and field validation showed the accuracy of mapping rice fields to be between 82.3% and 100%, and the Kappa coefficient was 0.86 to 0.99. A significant positive correlation was observed between the abundance of the vector Anopheles funestus and temperature; the correlation coefficient was 0.599 (p < 0.001). A significant negative correlation was observed between vector abundance and human population density: the correlation coefficient was -0.551 (p < 0.003). Factor weights were determined by pair-wise comparison and the consistency ratio was 0.04. Risk maps of the six study zones were obtained according to a gradient of risk. Nine of thirteen results of alert confirmed by the Epidemiological Surveillance Post were in concordance with the risk map. Conclusion This study is particularly valuable for the management of vector control programmes, and particularly the reduction of the vector population with a view to preventing disease. The risk map obtained can be used to identify priority zones for the management of resources, and also help avoid systematic and generalised spraying throughout the highlands: such spraying is particularly difficult and expensive. The accuracy of the mapping, both as concerns time and space, is dependent on the availability of data. Continuous monitoring of malaria transmission factors must be undertaken to detect any changes. A regular case notification allows risk map to be verified. These actions should therefore be implemented so that risk maps can be satisfactorily assessed. PMID:17261177

  6. Pedagogical Models of Concordance Use: Correlations between Concordance User Preferences

    ERIC Educational Resources Information Center

    Ballance, Oliver James

    2017-01-01

    One of the most promising avenues of research in computer-assisted language learning is the potential for language learners to make use of language corpora. However, using a corpus requires use of a corpus tool as an interface, typically a concordancer. How such a tool can be made most accessible to learners is an important issue. Specifically,…

  7. Assessment of interobserver concordance in polysomnography scoring of sleep bruxism☆

    PubMed Central

    Ferraz, Otávio; de Moura Guimarães, Thais; Maluly Filho, Milton; Dal-Fabbro, Cibele; Abraão Crosara Cunha, Thays; Cristina Lotaif, Ana; Cristina Barros Schütz, Teresa; Santos-Silva, Rogério; Tufik, Sergio; Bittencourt, Lia

    2015-01-01

    Introduction Objective evaluation of sleep bruxism (SB) using whole-night polysomnography (PSG) is relevant for diagnostic confirmation. Nevertheless, the PSG electromyogram (EMG) scoring may give rise to controversy, particularly when audiovisual monitoring is not performed. Therefore, the present study assessed the concordance between two independent scorers to visual SB on a PSG performed without audiovisual monitoring. Methods Fifty-six PSG tests were scored from individuals with clinical history and polysomnography criteria of SB. In addition to the protocol of conventional whole-night PSG, electrodes were also placed bilaterally on the masseter and temporal muscles. Visual EMG scoring without audio video monitoring was scored by two independent scorers (Dentist 1 and Dentist 2) according the recommendations formulated in the AASM manual (2007). Kendall Tau correlation was used to assess interobserver concordance relative to variables “total duration of events (seconds), “shortest events”, “longest events” and index in each phasic, tonic or mixed event. Results The correlation was positive and significant relative to all the investigated variables, being T>0.54. Conclusion It was found a good inter-examiner concordance rate in SB scoring in absence of audio video monitoring. PMID:26779318

  8. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    PubMed

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  9. Reliability of basal plasma vasopressin concentrations in healthy male adults.

    PubMed

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Djupesland, Per G; Andreassen, Ole A

    2017-10-01

    The neuropeptides oxytocin (OT) and arginine vasopressin (AVP) play important and interrelated roles in modulating mammalian social behaviour. While the OT system has received considerable research attention for its potential to treat psychiatric symptoms, comparatively little is known about the role of the AVP system in human social behaviour. To better understand the intraindividual stability of basal AVP, the present study assessed the reproducibility of basal plasma AVP concentrations. Basal plasma AVP was assessed at four sampling points separated by 8 days, on average, in 16 healthy adult males. Only one out of six comparisons revealed strong evidence for reproducibility of basal AVP concentrations (visit 2 vs. visit 4: r=0.8, p0.1). The concordance correlation coefficient [0.15, 95% CI (-0.55, 0.73)] also revealed poor overall reproducibility. Poor reliability of basal AVP concentrations suggests future work covarying AVP with trait markers should proceed with careful consideration of intraindividual fluctuations.

  10. Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.

    PubMed

    Sun, Jun; Liu, Yan-Cheng; Yan, Song-Hua; Wang, Sha-Sha; Lester, D Kevin; Zeng, Ji-Zhou; Miao, Jun; Zhang, Kuan

    2018-02-01

    The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients. Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis. The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001. The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  11. A comparison of individual and population-derived vascular input functions for quantitative DCE-MRI in rats.

    PubMed

    Hormuth, David A; Skinner, Jack T; Does, Mark D; Yankeelov, Thomas E

    2014-05-01

    Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) can quantitatively and qualitatively assess physiological characteristics of tissue. Quantitative DCE-MRI requires an estimate of the time rate of change of the concentration of the contrast agent in the blood plasma, the vascular input function (VIF). Measuring the VIF in small animals is notoriously difficult as it requires high temporal resolution images limiting the achievable number of slices, field-of-view, spatial resolution, and signal-to-noise. Alternatively, a population-averaged VIF could be used to mitigate the acquisition demands in studies aimed to investigate, for example, tumor vascular characteristics. Thus, the overall goal of this manuscript is to determine how the kinetic parameters estimated by a population based VIF differ from those estimated by an individual VIF. Eight rats bearing gliomas were imaged before, during, and after an injection of Gd-DTPA. K(trans), ve, and vp were extracted from signal-time curves of tumor tissue using both individual and population-averaged VIFs. Extended model voxel estimates of K(trans) and ve in all animals had concordance correlation coefficients (CCC) ranging from 0.69 to 0.98 and Pearson correlation coefficients (PCC) ranging from 0.70 to 0.99. Additionally, standard model estimates resulted in CCCs ranging from 0.81 to 0.99 and PCCs ranging from 0.98 to 1.00, supporting the use of a population based VIF if an individual VIF is not available. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Improved kinect-based spatiotemporal and kinematic treadmill gait assessment.

    PubMed

    Eltoukhy, Moataz; Oh, Jeonghoon; Kuenze, Christopher; Signorile, Joseph

    2017-01-01

    A cost-effective, clinician friendly gait assessment tool that can automatically track patients' anatomical landmarks can provide practitioners with important information that is useful in prescribing rehabilitative and preventive therapies. This study investigated the validity and reliability of the Microsoft Kinect v2 as a potential inexpensive gait analysis tool. Ten healthy subjects walked on a treadmill at 1.3 and 1.6m·s -1 , as spatiotemporal parameters and kinematics were extracted concurrently using the Kinect and three-dimensional motion analysis. Spatiotemporal measures included step length and width, step and stride times, vertical and mediolateral pelvis motion, and foot swing velocity. Kinematic outcomes included hip, knee, and ankle joint angles in the sagittal plane. The absolute agreement and relative consistency between the two systems were assessed using interclass correlations coefficients (ICC2,1), while reproducibility between systems was established using Lin's Concordance Correlation Coefficient (rc). Comparison of ensemble curves and associated 90% confidence intervals (CI90) of the hip, knee, and ankle joint angles were performed to investigate if the Kinect sensor could consistently and accurately assess lower extremity joint motion throughout the gait cycle. Results showed that the Kinect v2 sensor has the potential to be an effective clinical assessment tool for sagittal plane knee and hip joint kinematics, as well as some spatiotemporal temporal variables including pelvis displacement and step characteristics during the gait cycle. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Comparison of international normalized ratio audit parameters in patients enrolled in GARFIELD-AF and treated with vitamin K antagonists.

    PubMed

    Fitzmaurice, David A; Accetta, Gabriele; Haas, Sylvia; Kayani, Gloria; Lucas Luciardi, Hector; Misselwitz, Frank; Pieper, Karen; Ten Cate, Hugo; Turpie, Alexander G G; Kakkar, Ajay K

    2016-08-01

    Vitamin K antagonist (VKA) therapy for stroke prevention in atrial fibrillation (AF) requires monitoring of the international normalized ratio (INR). We evaluated the agreement between two INR audit parameters, frequency in range (FIR) and proportion of time in the therapeutic range (TTR), using data from a global population of patients with newly diagnosed non-valvular AF, the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF). Among 17 168 patients with 1-year follow-up data available at the time of the analysis, 8445 received VKA therapy (±antiplatelet therapy) at enrolment, and of these patients, 5066 with ≥3 INR readings and for whom both FIR and TTR could be calculated were included in the analysis. In total, 70 905 INRs were analysed. At the patient level, TTR showed higher values than FIR (mean, 56·0% vs 49·8%; median, 59·7% vs 50·0%). Although patient-level FIR and TTR values were highly correlated (Pearson correlation coefficient [95% confidence interval; CI], 0·860 [0·852-0·867]), estimates from individuals showed widespread disagreement and variability (Lin's concordance coefficient [95% CI], 0·829 [0·821-0·837]). The difference between FIR and TTR explained 17·4% of the total variability of measurements. These results suggest that FIR and TTR are not equivalent and cannot be used interchangeably. © 2016 John Wiley & Sons Ltd.

  14. Temporal patterns of drug use - a pilot study.

    PubMed

    Sinnett, E R

    1976-12-01

    Examination of pilot data for classes of drugs showed significant coefficients of concordance for ranked times of most common to least common use. Marijuana, psychedelics, and amphetamines were used most commonly from 6 to 10 p.m., coincidental with temporal patterns for viewing television suggests recreational use. Use times for caffeine were completely different.

  15. Somatostatin receptor subtype 2 in high-grade gliomas: PET/CT with (68)Ga-DOTA-peptides, correlation to prognostic markers, and implications for targeted radiotherapy.

    PubMed

    Kiviniemi, Aida; Gardberg, Maria; Frantzén, Janek; Pesola, Marko; Vuorinen, Ville; Parkkola, Riitta; Tolvanen, Tuula; Suilamo, Sami; Johansson, Jarkko; Luoto, Pauliina; Kemppainen, Jukka; Roivainen, Anne; Minn, Heikki

    2015-01-01

    High-grade gliomas (HGGs) express somatostatin receptors (SSTR), rendering them candidates for peptide receptor radionuclide therapy (PRRT). Our purpose was to evaluate the potential of (68)Ga-DOTA-1-Nal(3)-octreotide ((68)Ga-DOTANOC) or (68)Ga-DOTA-Tyr(3)-octreotide ((68)Ga-DOTATOC) to target SSTR subtype 2 (SSTR2) in HGGs, and to study the association between SSTR2 expression and established biomarkers. Twenty-seven patients (mean age 52 years) with primary or recurrent HGG prospectively underwent (68)Ga-DOTA-peptide positron emission tomography/computed tomography (PET/CT) before resection. Maximum standardized uptake values (SUVmax) and receptor binding potential (BP) were calculated on PET/CT and disruption of blood-brain barrier (BBB) from contrast-enhanced T1-weighted magnetic resonance imaging (MRI-T1-Gad). Tumor volume concordance between PET and MRI-T1-Gad was assessed by Dice similarity coefficient (DC) and correlation by Spearman's rank. Immunohistochemically determined SSTR2 status was compared to receptor imaging findings, prognostic biomarkers, and survival with Kruskal-Wallis, Pearson chi-square, and multivariate Cox regression, respectively. All 19 HGGs with disrupted BBB demonstrated tracer uptake. Tumor SUVmax (2.25 ± 1.33) correlated with MRI-T1-Gad (r = 0.713, P = 0.001) although DC 0.41 ± 0.19 suggested limited concordance. SSTR2 immunohistochemistry was regarded as positive in nine HGGs (32%) but no correlation with SUVmax or BP was found. By contrast, SSTR2 expression was associated with IDH1 mutation (P = 0.007), oligodendroglioma component (P = 0.010), lower grade (P = 0.005), absence of EGFR amplification (P = 0.021), and longer progression-free survival (HR 0.161, CI 0.037 to 0.704, P = 0.015). In HGGs, uptake of (68)Ga-DOTA-peptides is associated with disrupted BBB and cannot be predicted by SSTR2 immunohistochemistry. Thus, PET/CT shows limited value to detect HGGs suitable for PRRT. However, high SSTR2 expression portends favorable outcome along with established biomarkers such as IDH1 mutation. ClinicalTrials.gov NCT01460706.

  16. SU-F-R-51: Radiomics in CT Perfusion Maps of Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nesteruk, M; Riesterer, O; Veit-Haibach, P

    2016-06-15

    Purpose: The aim of this study was to test the predictive value of radiomics features of CT perfusion (CTP) for tumor control, based on a preselection of radiomics features in a robustness study. Methods: 11 patients with head and neck cancer (HNC) and 11 patients with lung cancer were included in the robustness study to preselect stable radiomics parameters. Data from 36 HNC patients treated with definitive radiochemotherapy (median follow-up 30 months) was used to build a predictive model based on these parameters. All patients underwent pre-treatment CTP. 315 texture parameters were computed for three perfusion maps: blood volume, bloodmore » flow and mean transit time. The variability of texture parameters was tested with respect to non-standardizable perfusion computation factors (noise level and artery contouring) using intraclass correlation coefficients (ICC). The parameter with the highest ICC in the correlated group of parameters (inter-parameter Spearman correlations) was tested for its predictive value. The final model to predict tumor control was built using multivariate Cox regression analysis with backward selection of the variables. For comparison, a predictive model based on tumor volume was created. Results: Ten parameters were found to be stable in both HNC and lung cancer regarding potentially non-standardizable factors after the correction for inter-parameter correlations. In the multivariate backward selection of the variables, blood flow entropy showed a highly significant impact on tumor control (p=0.03) with concordance index (CI) of 0.76. Blood flow entropy was significantly lower in the patient group with controlled tumors at 18 months (p<0.1). The new model showed a higher concordance index compared to the tumor volume model (CI=0.68). Conclusion: The preselection of variables in the robustness study allowed building a predictive radiomics-based model of tumor control in HNC despite a small patient cohort. This model was found to be superior to the volume-based model. The project was supported by the KFSP Tumor Oxygenation of the University of Zurich, by a grant of the Center for Clinical Research, University and University Hospital Zurich and by a research grant from Merck (Schweiz) AG.« less

  17. Early Executive Function and Mathematics Relations: Correlation Does Not Ensure Concordance.

    PubMed

    Mazzocco, Michèle M M; Chan, Jenny Yun-Chen; Bock, Allison M

    2017-01-01

    In this chapter, we address one potentially overlooked component of the relation between executive function (EF) skills and early mathematics, a relation for which there is widespread empirical support. Evidence for this relation has, thus far, been largely correlational. Here we emphasize that because positive correlations do not guarantee concordance among all members of a sample or population, a small but meaningful number of children may either fare well in mathematics despite poor EF skills, or may have strong EF skills despite weak mathematics skills. We propose that attention to different profiles of discordance for EF and mathematics may help identify individualized learning needs for students at risk for mathematics difficulties and disabilities. © 2017 Elsevier Inc. All rights reserved.

  18. Fully Automated Quantification of Cytomegalovirus (CMV) in Whole Blood with the New Sensitive Abbott RealTime CMV Assay in the Era of the CMV International Standard

    PubMed Central

    Schnepf, Nathalie; Scieux, Catherine; Resche-Riggon, Matthieu; Feghoul, Linda; Xhaard, Alienor; Gallien, Sébastien; Molina, Jean-Michel; Socié, Gérard; Viglietti, Denis; Simon, François; Mazeron, Marie-Christine

    2013-01-01

    Fully standardized reproducible and sensitive quantification assays for cytomegalovirus (CMV) are needed to better define thresholds for antiviral therapy initiation and interruption. We evaluated the newly released Abbott RealTime CMV assay for CMV quantification in whole blood (WB) that includes automated extraction and amplification (m2000 RealTime system). Sensitivity, accuracy, linearity, and intra- and interassay variability were validated in a WB matrix using Quality Control for Molecular Diagnostics (QCMD) panels and the WHO international standard (IS). The intra- and interassay coefficients of variation were 1.37% and 2.09% at 5 log10 copies/ml and 2.41% and 3.80% at 3 log10 copies/ml, respectively. According to expected values for the QCMD and Abbott RealTime CMV methods, the lower limits of quantification were 104 and <50 copies/ml, respectively. The conversion factor between international units and copies (2.18), determined from serial dilutions of the WHO IS in WB, was significantly different from the factor provided by the manufacturer (1.56) (P = 0.001). Results from 302 clinical samples were compared with those from the Qiagen artus CMV assay on the same m2000 RealTime system. The two assays provided highly concordant results (concordance correlation coefficient, 0.92), but the Abbott RealTime CMV assay detected and quantified, respectively, 20.6% and 47.8% more samples than the Qiagen/artus CMV assay. The sensitivity and reproducibility of the results, along with the automation, fulfilled the quality requirements for implementation of the Abbott RealTime CMV assay in clinical settings. Our results highlight the need for careful validation of conversion factors provided by the manufacturers for the WHO IS in WB to allow future comparison of results obtained with different assays. PMID:23616450

  19. Comparison of two methods of measuring gastric pH.

    PubMed

    Neill, K M; Rice, K T; Ahern, H L

    1993-01-01

    To assess the agreement between two methods of measuring gastric pH in critically ill patients (multiple band litmus paper-tested aspirations versus a meter-read probe located in the tip of a nasogastric tube) and to compare nurse satisfaction with both methods of measuring pH. Prospective, correlational, nonprobability sample. Mid-Atlantic, semirural Veterans Affairs Medical Center. 39 male, surgical, critical care patients, who were nasogastrically intubated in the operating room and received nothing by mouth. NURSES: Twenty-seven registered nurses on the medical-surgical intensive care staff. Differences in pH units as determined by two methods of measurement and nurse satisfaction scores. Litmus paper-tested aspirations versus a meter-read probe located in the tip of the nasogastric tube, measured every 2 hours for 48 hours. A nurse satisfaction assessment form for both measurement methods at entry, 6 months, and 12 months. All measures of association, Pearson's r (0.79), the concordance coefficient (0.74), and eta (0.88), were high. The concordance coefficient measures indicated sufficient agreement between the two methods at the initial and 24 hour measurement times (Cb) = 0.97, 0.97, and 0.94), but not at 48 hours. The meter method indicated prophylaxis was needed when the paper did not, more often than did the paper method (9.3% vs 5.2%). A significant difference between methods was found only at the last reading at 48 hours (z = -2.24, p < .0249). MANOVA revealed that nurses' preference for the meter method was significant (F = 139.48, df = 1.18) and increased over time (F = 4.77, df = 2,36). The gastric probe method of measuring pH is an accurate substitution up to 48 hours for the litmus-paper aspiration method in the postoperative patient who is receiving nothing by mouth. Nurses prefer the gastric probe method of measuring pH over the litmus-paper method because they judge it to be safer, faster, and more accurate.

  20. Ageing midface: The impact of surgeon's experience on the consistency in the assessment and proposed management.

    PubMed

    Hazrati, Ali; Izadpanah, Ali; Zadeh, Teanoosh; Gosman, Amanda; Chao, James J; Dobke, Marek K

    2011-02-01

    An individual's face undergoes numerous changes throughout life. Since mid-face aesthetic units are key areas for rejuvenation procedures, their comprehensive assessment is essential for the development of any aesthetic management plan. Despite the availability of many evaluation criteria for treatment of mid-face ageing, there are discrepancies existing in both assessment and management approaches. The goal of this study was to determine if there are any identifiable profiles of clinical judgements and approaches related to the level of surgeon's experience. Forty seven standardised non-digital and not altered natural size photographic images of patients' faces (front and profile) were presented to eight senior board certified plastic surgeons, eight junior non-board certified plastic surgeons and eight plastic surgery residents from an independent program. Surveyed physicians were 'blinded' from each other and asked to assess five different major features characterising ageing mid-face. An interclass correlation data analysis was performed and the Cronbach coefficient alpha values were computed for each category. Responses obtained from senior plastic surgeons were consistently characterised by higher Cronbach coefficient alpha values indicating higher concordance. The highest agreement levels were obtained for the assessment of rhytids and jowls across all groups and the lowest agreement levels were obtained for the assessment and recommendation of upper lip management. This study illustrated that discrepancies in clinical assessments and surgical management exist among surgeons involved in the aesthetic surgery of the mid-face ageing. It appears that the level of surgeon's experience significantly impacts the inter-rater reliability and consensus in assessment and treatment of mid-face ageing. The most senior plastic surgeons' assessment and recommendations had the highest level of concordance while the junior non-board certified plastic surgeons and the residents group produced variations with less consistency. Copyright © 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Evaluating Random Error in Clinician-Administered Surveys: Theoretical Considerations and Clinical Applications of Interobserver Reliability and Agreement.

    PubMed

    Bennett, Rebecca J; Taljaard, Dunay S; Olaithe, Michelle; Brennan-Jones, Chris; Eikelboom, Robert H

    2017-09-18

    The purpose of this study is to raise awareness of interobserver concordance and the differences between interobserver reliability and agreement when evaluating the responsiveness of a clinician-administered survey and, specifically, to demonstrate the clinical implications of data types (nominal/categorical, ordinal, interval, or ratio) and statistical index selection (for example, Cohen's kappa, Krippendorff's alpha, or interclass correlation). In this prospective cohort study, 3 clinical audiologists, who were masked to each other's scores, administered the Practical Hearing Aid Skills Test-Revised to 18 adult owners of hearing aids. Interobserver concordance was examined using a range of reliability and agreement statistical indices. The importance of selecting statistical measures of concordance was demonstrated with a worked example, wherein the level of interobserver concordance achieved varied from "no agreement" to "almost perfect agreement" depending on data types and statistical index selected. This study demonstrates that the methodology used to evaluate survey score concordance can influence the statistical results obtained and thus affect clinical interpretations.

  2. A concordance-based study to assess doctors’ and nurses’ mental models in Internal Medicine

    PubMed Central

    Chan, K. C. Gary; Muller-Juge, Virginie; Cullati, Stéphane; Hudelson, Patricia; Maître, Fabienne; Vu, Nu V.; Savoldelli, Georges L.; Nendaz, Mathieu R.

    2017-01-01

    Interprofessional collaboration between doctors and nurses is based on team mental models, in particular for each professional’s roles. Our objective was to identify factors influencing concordance on the expectations of doctors’ and nurses’ roles and responsibilities in an Internal Medicine ward. Using a dataset of 196 doctor-nurse pairs (14x14 = 196), we analyzed choices and prioritized management actions of 14 doctors and 14 nurses in six clinical nurse role scenarios, and in five doctor role scenarios (6 options per scenario). In logistic regression models with a non-nested correlation structure, we evaluated concordance among doctors and nurses, and adjusted for potential confounders (including prior experience in Internal Medicine, acuteness of case and gender). Concordance was associated with number of female professionals (adjusted OR 1.32, 95% CI 1.02 to 1.73), for acute situations (adjusted OR 2.02, 95% CI 1.13 to 3.62), and in doctor role scenarios (adjusted OR 2.19, 95% CI 1.32 to 3.65). Prior experience and country of training were not significant predictors of concordance. In conclusion, our concordance-based approach helped us identify areas of lower concordance in expected doctor-nurse roles and responsibilities, particularly in non-acute situations, which can be targeted by future interprofessional, educational interventions. PMID:28792524

  3. Measurement of the area of venous ulcers using two software programs.

    PubMed

    Eberhardt, Thaís Dresch; Lima, Suzinara Beatriz Soares de; Lopes, Luis Felipe Dias; Borges, Eline de Lima; Weiller, Teresinha Heck; Fonseca, Graziele Gorete Portella da

    2016-12-19

    to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm². comparar a mensuração de área de úlceras venosas por meio dos softwares AutoCAD(r) e Image Tool. trata-se de um estudo de avaliação de reprodutibilidade de testes, realizado em um ambulatório de angiologia de um hospital universitário. Os dados foram coletados de 21 pacientes com úlceras venosas, no período de março a julho de 2015, por meio de formulário de coleta e fotografia das feridas. Cinco enfermeiros (avaliadores) do Grupo de Estudos de Lesões de Pele do hospital participaram da pesquisa. As feridas foram mensuradas em ambos os softwares. Os dados foram analisados por meio do Coeficiente de correlação intraclasse, Coeficiente de correlação de concordância e procedimento de Bland e Altman. A pesquisa respeitou os aspectos éticos de acordo com a legislação vigente. os tamanhos das úlceras apresentaram grande amplitude, porém, sem diferença significativa entre as mensurações, existe excelente correlação intraclasse e de concordância entre os softwares, os quais parecem ser mais precisos na mensuração de feridas com área > 10 cm². o uso de ambos os softwares é indicado para a mensuração de úlceras venosas, parecendo ser mais precisos quando utilizados para mensurar feridas com área > 10 cm². comparar la medida del área de úlceras venosas por medio de los softwares AutoCAD(r) e Image Tool. se trata de un estudio de evaluación de reproducibilidad de pruebas, realizado en un ambulatorio de angiología de un hospital universitario. Los datos fueron recolectados de 21 pacientes con úlceras venosas, en el período de marzo a julio de 2015, por medio de formulario de recolección y fotografías de las heridas. Cinco enfermeros (evaluadores) del Grupo de Estudios de Lesiones de Piel del hospital participaron de la investigación. Las heridas fueron medidas en ambos softwares. Los datos fueron analizados por medio de: Coeficiente de correlación intraclase, Coeficiente de correlación de concordancia y Procedimiento de Bland y Altman. La investigación respetó los aspectos éticos de acuerdo con la legislación vigente. los tamaños de las úlceras presentaron gran amplitud, sin embargo, sin diferencia significativa entre las medidas; existe excelente correlación intraclase y de concordancia entre los softwares, los que parecen ser más precisos en medidas de heridas con área > 10 cm². el uso de ambos softwares es indicado para medir úlceras venosas, pareciendo ser más precisos cuando utilizados para medir heridas con área > 10 cm².

  4. Comparison of Combined Endoscopic Ultrasonography and Endoscopic Secretin Testing With the Traditional Secretin Pancreatic Function Test in Patients With Suspected Chronic Pancreatitis: A Prospective Crossover Study.

    PubMed

    Kothari, Darshan; Ketwaroo, Gyanprakash; Sawhney, Mandeep S; Freedman, Steven D; Sheth, Sunil G

    2017-07-01

    We aimed to determine the feasibility and accuracy of a combined endoscopic ultrasonography (EUS) with a shortened pancreatic function testing (sEUS) for structural and functional assessment using a single instrument in patients with suspected chronic pancreatitis (CP). We completed a prospective crossover study, enrolling patients with suspected CP. Patients who underwent both traditional 1-hour secretin pancreatic function test (sPFT) and sEUS were included in the analysis. We compared study results for test concordance and for correlation of peak bicarbonate concentrations. Eleven (64.7%) of 17 patients had concordant sPFT and sEUS findings when the cutoff for peak bicarbonate was 80 mEq/L. Six patients had discordant findings with a negative sPFT and positive sEUS. This poor concordance suggests that sEUS is an unreliable functional test. Lowering the sEUS cutoff to 70 mEq/L resulted in improved concordance (64.7% vs 70.6%). Finally, there was no significant correlation between peak bicarbonate concentrations (r = 0.47; 95% confidence interval, -0.02 to 0.79) in these 2 functional tests. We demonstrate poor concordance between sPFT and sEUS suggesting that a combined shortened functional and structural test using a single instrument may not be a feasible test for diagnosis of suspected CP when a cutoff of 80 mEq/L is used.

  5. The Influence of Physical Body Traits and Masculinity on Anal Sex Roles in Gay and Bisexual Men

    PubMed Central

    Moskowitz, David A.; Hart, Trevor A.

    2016-01-01

    Sociological, psychological, and public health studies document that many gay and bisexual men may self-label by their anal penetrative role (i.e., bottom or exclusively receptive; top or exclusively insertive; or versatile, both receptive and insertive during anal intercourse). Yet, what orients men to think of themselves as tops, bottoms or versatiles is poorly understood. We surveyed 429 men engaging in same-sex anal intercourse to investigate the degree to which anal penetrative self-identity was concordant with actual penetrative behavior. Additionally, the roles of masculinity and physical body traits (e.g., penis size, muscularity, height, hairiness, and weight) were tested as correlates of anal penetrative identity and identity-behavior concordance. Tops and bottoms showed a high degree of concordance between identity and enacted behavior; however, only half of versatiles reported concordant identity and behavior (i.e., wanting to be versatile and actually reporting versatile behavior). Generally, tops reported larger penises than bottoms. They also reported being comparatively more masculine than bottoms. Versatiles fell somewhat between the tops and bottoms on these traits. Of the six independent variables, penis size and masculinity were the only two factors to influence concordance or discordance between identity and penetrative behavior. Our study suggests that the correlates of gay men’s sexual self-labels may depend on objective traits in addition to the subjective pleasure associated with receptive or insertive anal intercourse. PMID:21465269

  6. Evaluation of Lumipulse® G1200 for the measurement of six tumor markers: Comparison with AIA® 2000.

    PubMed

    de Rancher, Marie-Aude Robert; Oudart, Jean-Baptiste; Maquart, François-Xavier; Monboisse, Jean Claude; Ramont, Laurent

    2016-11-01

    Tumor marker assays are daily practiced, for screening and follow up of cancers. Interassay precision is an important parameter for the interpretation of the kinetics of the markers, in order to conclude to the efficiency or failure of treatment. The aim of this study was to compare two automated Immunoassay analyzers, Lumipulse® G1200 and AIA® 2000. Both analyzers used an immunoassay system but with different antibodies. Six tumor markers commonly used were studied: AFP, PSA, CA 19-9, CA 15-3, CA 125 and CEA. 253 samples have been collected over a period of one month and analyzed by both analyzers. Regression of Passing-Badblock and Bland-Altman diagram were used to analyze the results for AFP (n=36), PSA (n=39), CA-125 (n=40), CA 15-3 (n=40), CA 19-9 (n=46) and CEA (n=52) were performed. Analytical performances of Lumipulse® G1200 highlighted the good inter-run and intra-run precision of the analyzer. We obtained a good correlation coefficient between Lumipulse G1200® and AIA 2000®, >0.96 for most markers except CA 19-9 which provided a correlation coefficient significantly lower than that obtained with other markers. The concordance for all markers was >94% except for CA 19-9 (83.7%). This study showed a good correlation between the two analyzers and, therefore, a transfer from one analyzer to the other is possible for the different markers studied. However, we found here the classical difficulty to transfer this type of analysis, due to the absence of method standardization. This difficulty was particularly illustrated by CA19-9. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. The Sedentary Time and Activity Reporting Questionnaire (STAR-Q): reliability and validity against doubly labeled water and 7-day activity diaries.

    PubMed

    Csizmadi, Ilona; Neilson, Heather K; Kopciuk, Karen A; Khandwala, Farah; Liu, Andrew; Friedenreich, Christine M; Yasui, Yutaka; Rabasa-Lhoret, Rémi; Bryant, Heather E; Lau, David C W; Robson, Paula J

    2014-08-15

    We determined measurement properties of the Sedentary Time and Activity Reporting Questionnaire (STAR-Q), which was designed to estimate past-month activity energy expenditure (AEE). STAR-Q validity and reliability were assessed in 102 adults in Alberta, Canada (2009-2011), who completed 14-day doubly labeled water (DLW) protocols, 7-day activity diaries on day 15, and the STAR-Q on day 14 and again at 3 and 6 months. Three-month reliability was substantial for total energy expenditure (TEE) and AEE (intraclass correlation coefficients of 0.84 and 0.73, respectively), while 6-month reliability was moderate. STAR-Q-derived TEE and AEE were moderately correlated with DLW estimates (Spearman's ρs of 0.53 and 0.40, respectively; P < 0.001), and on average, the STAR-Q overestimated TEE and AEE (median differences were 367 kcal/day and 293 kcal/day, respectively). Body mass index-, age-, sex-, and season-adjusted concordance correlation coefficients (CCCs) were 0.24 (95% confidence interval (CI): 0.07, 0.36) and 0.21 (95% CI: 0.11, 0.32) for STAR-Q-derived versus DLW-derived TEE and AEE, respectively. Agreement between the diaries and STAR-Q (metabolic equivalent-hours/day) was strongest for occupational sedentary time (adjusted CCC = 0.76, 95% CI: 0.64, 0.85) and overall strenuous activity (adjusted CCC = 0.64, 95% CI: 0.49, 0.76). The STAR-Q demonstrated substantial validity for estimating occupational sedentary time and strenuous activity and fair validity for ranking individuals by AEE. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors.

    PubMed

    Castel, Anne-Laure; Szymanski, Catherine; Delelis, François; Levy, Franck; Menet, Aymeric; Mailliet, Amandine; Marotte, Nathalie; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre

    2014-02-01

    Speckle tracking is a relatively new, largely angle-independent technique used for the evaluation of myocardial longitudinal strain (LS). However, significant differences have been reported between LS values obtained by speckle tracking with the first generation of software products. To compare LS values obtained with the most recently released equipment from two manufacturers. Systematic scanning with head-to-head acquisition with no modification of the patient's position was performed in 64 patients with equipment from two different manufacturers, with subsequent off-line post-processing for speckle tracking LS assessment (Philips QLAB 9.0 and General Electric [GE] EchoPAC BT12). The interobserver variability of each software product was tested on a randomly selected set of 20 echocardiograms from the study population. GE and Philips interobserver coefficients of variation (CVs) for global LS (GLS) were 6.63% and 5.87%, respectively, indicating good reproducibility. Reproducibility was very variable for regional and segmental LS values, with CVs ranging from 7.58% to 49.21% with both software products. The concordance correlation coefficient (CCC) between GLS values was high at 0.95, indicating substantial agreement between the two methods. While good agreement was observed between midwall and apical regional strains with the two software products, basal regional strains were poorly correlated. The agreement between the two software products at a segmental level was very variable; the highest correlation was obtained for the apical cap (CCC 0.90) and the poorest for basal segments (CCC range 0.31-0.56). A high level of agreement and reproducibility for global but not for basal regional or segmental LS was found with two vendor-dependent software products. This finding may help to reinforce clinical acceptance of GLS in everyday clinical practice. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables.

    PubMed

    Mentiplay, Benjamin F; Perraton, Luke G; Bower, Kelly J; Pua, Yong-Hao; McGaw, Rebekah; Heywood, Sophie; Clark, Ross A

    2015-07-16

    The revised Xbox One Kinect, also known as the Microsoft Kinect V2 for Windows, includes enhanced hardware which may improve its utility as a gait assessment tool. This study examined the concurrent validity and inter-day reliability of spatiotemporal and kinematic gait parameters estimated using the Kinect V2 automated body tracking system and a criterion reference three-dimensional motion analysis (3DMA) marker-based camera system. Thirty healthy adults performed two testing sessions consisting of comfortable and fast paced walking trials. Spatiotemporal outcome measures related to gait speed, speed variability, step length, width and time, foot swing velocity and medial-lateral and vertical pelvis displacement were examined. Kinematic outcome measures including ankle flexion, knee flexion and adduction and hip flexion were examined. To assess the agreement between Kinect and 3DMA systems, Bland-Altman plots, relative agreement (Pearson's correlation) and overall agreement (concordance correlation coefficients) were determined. Reliability was assessed using intraclass correlation coefficients, Cronbach's alpha and standard error of measurement. The spatiotemporal measurements had consistently excellent (r≥0.75) concurrent validity, with the exception of modest validity for medial-lateral pelvis sway (r=0.45-0.46) and fast paced gait speed variability (r=0.73). In contrast kinematic validity was consistently poor to modest, with all associations between the systems weak (r<0.50). In those measures with acceptable validity, the inter-day reliability was similar between systems. In conclusion, while the Kinect V2 body tracking may not accurately obtain lower body kinematic data, it shows great potential as a tool for measuring spatiotemporal aspects of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The stable traits of melanoma genetics: an alternate approach to target discovery

    PubMed Central

    2012-01-01

    Background The weight that gene copy number plays in transcription remains controversial; although in specific cases gene expression correlates with copy number, the relationship cannot be inferred at the global level. We hypothesized that genes steadily expressed by 15 melanoma cell lines (CMs) and their parental tissues (TMs) should be critical for oncogenesis and their expression most frequently influenced by their respective copy number. Results Functional interpretation of 3,030 transcripts concordantly expressed (Pearson's correlation coefficient p-value < 0.05) by CMs and TMs confirmed an enrichment of functions crucial to oncogenesis. Among them, 968 were expressed according to the transcriptional efficiency predicted by copy number analysis (Pearson's correlation coefficient p-value < 0.05). We named these genes, "genomic delegates" as they represent at the transcriptional level the genetic footprint of individual cancers. We then tested whether the genes could categorize 112 melanoma metastases. Two divergent phenotypes were observed: one with prevalent expression of cancer testis antigens, enhanced cyclin activity, WNT signaling, and a Th17 immune phenotype (Class A). This phenotype expressed, therefore, transcripts previously associated to more aggressive cancer. The second class (B) prevalently expressed genes associated with melanoma signaling including MITF, melanoma differentiation antigens, and displayed a Th1 immune phenotype associated with better prognosis and likelihood to respond to immunotherapy. An intermediate third class (C) was further identified. The three phenotypes were confirmed by unsupervised principal component analysis. Conclusions This study suggests that clinically relevant phenotypes of melanoma can be retraced to stable oncogenic properties of cancer cells linked to their genetic back bone, and offers a roadmap for uncovering novel targets for tailored anti-cancer therapy. PMID:22537248

  11. The ability of a sustained within-session finding of pain reduction during traction to dictate improved outcomes from a manual therapy approach on patients with osteoarthritis of the hip.

    PubMed

    Wright, Alexis A; Abbott, J Haxby; Baxter, Dave; Cook, Chad

    2010-09-01

    THE OBJECTIVES OF THIS STUDY WERE TO: (1) determine the association of a within-session finding after traction of the hip with self-report of well-being, pain, and self-report of function at 9 weeks; and (2) to determine if the interactions between the within-session finding and the outcome measure are different between groups of patients with hip OA who receive and who do not receive manual therapy. Data were retrospectively analysed in 70 subjects who were part of a randomized control trial. Correlation analyses of within-session findings from the initial visit after traction of a concordantly painful hip were compared to self-report measures for function, pain, and well-being at 9 weeks. A comparison of slope coefficients between manual therapy and non-manual therapy groups was performed to determine the interactive aspects of the within-session finding. Although the correlations for the manual therapy group were higher than for the supervised neglect group, none of the correlational analyses for both groups was strong or significant. Significant differences in the slope coefficients for well-being and pain were found, suggesting that the interactions between the within-session findings and the targeted outcomes were different in the manual therapy group versus supervised neglect group. These findings suggest that within-session findings during the initial evaluation are not strongly related to a positive outcome after manual therapy, although the interaction of the finding of a within-session change and the use of manual therapy is more compelling than the finding in a sample of patients who did not receive manual therapy.

  12. Using the value of Lin's concordance correlation coefficient as a criterion for efficient estimation of areas of leaves of eelgrass from noisy digital images.

    PubMed

    Echavarría-Heras, Héctor; Leal-Ramírez, Cecilia; Villa-Diharce, Enrique; Castillo, Oscar

    2014-01-01

    Eelgrass is a cosmopolitan seagrass species that provides important ecological services in coastal and near-shore environments. Despite its relevance, loss of eelgrass habitats is noted worldwide. Restoration by replanting plays an important role, and accurate measurements of the standing crop and productivity of transplants are important for evaluating restoration of the ecological functions of natural populations. Traditional assessments are destructive, and although they do not harm natural populations, in transplants the destruction of shoots might cause undesirable alterations. Non-destructive assessments of the aforementioned variables are obtained through allometric proxies expressed in terms of measurements of the lengths or areas of leaves. Digital imagery could produce measurements of leaf attributes without the removal of shoots, but sediment attachments, damage infringed by drag forces or humidity contents induce noise-effects, reducing precision. Available techniques for dealing with noise caused by humidity contents on leaves use the concepts of adjacency, vicinity, connectivity and tolerance of similarity between pixels. Selection of an interval of tolerance of similarity for efficient measurements requires extended computational routines with tied statistical inferences making concomitant tasks complicated and time consuming. The present approach proposes a simplified and cost-effective alternative, and also a general tool aimed to deal with any sort of noise modifying eelgrass leaves images. Moreover, this selection criterion relies only on a single statistics; the calculation of the maximum value of the Concordance Correlation Coefficient for reproducibility of observed areas of leaves through proxies obtained from digital images. Available data reveals that the present method delivers simplified, consistent estimations of areas of eelgrass leaves taken from noisy digital images. Moreover, the proposed procedure is robust because both the optimal interval of tolerance of similarity and the reproducibility of observed leaf areas through digital image surrogates were independent of sample size. The present method provides simplified, unbiased and non-destructive measurements of eelgrass leaf area. These measurements, in conjunction with allometric methods, can predict the dynamics of eelgrass biomass and leaf growth through indirect techniques, reducing the destructive effect of sampling, fundamental to the evaluation of eelgrass restoration projects thereby contributing to the conservation of this important seagrass species.

  13. Emphysema quantification and lung volumetry in chest X-ray equivalent ultralow dose CT - Intra-individual comparison with standard dose CT.

    PubMed

    Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W

    2017-06-01

    To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and reconstruction algorithms for reproducibility. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Expression of Bcl-2, Melan A and HMB-45 in Dysplastic Nevi.

    PubMed

    Patrascu, Oana Maria; Costache, Mariana; Dumitru, Adrian Vasile; Mehotin, Corina Nicoleta; Sajin, Maria; Lazaroiu, Anca Mihaela

    2016-03-01

    From the first recognition of dysplastic nevi as a pathology per se, many debates have been raised and many histological and immunohistological studies have been conducted in order to establish the true significance of these lesions. Therefore, the aim of this study was to establish if there is a correlation between HMB-45, Melan A and Bcl-2 expression and the grade of dysplasia, as well as between the marker's staining patterns. Ten dysplastic nevi from six female patients were selected and their histological features (size, dysplasia), as well as the immunohistological staining patterns, were studied (HMB-45, Melan A, Bcl-2). The Pearson correlation coefficient and regression was calculated with Windows Excel Data Analysis. We demonstrated that there was a notable correlation between the dysplasia and the size of the lesions (r(8)= 0.62 with p-value= 0.052), and also between Melan A and Bcl-2 (a r(6)= 0.73, p<0.05), but we did not obtain a statistically significant correlation between other features (p>0.05). We can affirm, at least in our cases, there is a correlation between the grade of dysplasia and the size of the lesion, and also, that there is a correlation between Melan A and Bcl-2 staining, explained by MITF gene. These results were only partial concordant with those in other studies, therefore a larger number of cases is recommended to be further analyzed in order to clearly draw a conclusion.

  15. Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study.

    PubMed

    Piscaglia, Fabio; Salvatore, Veronica; Mulazzani, Lorenzo; Cantisani, Vito; Colecchia, Antonio; Di Donato, Roberto; Felicani, Cristina; Ferrarini, Alessia; Gamal, Nesrine; Grasso, Valentina; Marasco, Giovanni; Mazzotta, Elena; Ravaioli, Federico; Ruggieri, Giacomo; Serio, Ilaria; Sitouok Nkamgho, Joules Fabrice; Serra, Carla; Festi, Davide; Schiavone, Cosima; Bolondi, Luigi

    2017-07-01

    Whether Fibroscan thresholds can be immediately adopted for none, some or all other shear wave elastography techniques has not been tested. The aim of the present study was to test the concordance of the findings obtained from 7 of the most recent ultrasound elastography machines with respect to Fibroscan. Sixteen hepatitis C virus-related patients with fibrosis ≥2 and having reliable results at Fibroscan were investigated in two intercostal spaces using 7 different elastography machines. Coefficients of both precision (an index of data dispersion) and accuracy (an index of bias correction factors expressing different magnitudes of changes in comparison to the reference) were calculated. Median stiffness values differed among the different machines as did coefficients of both precision (range 0.54-0.72) and accuracy (range 0.28-0.87). When the average of the measurements of two intercostal spaces was considered, coefficients of precision significantly increased with all machines (range 0.72-0.90) whereas of accuracy improved more scatteredly and by a smaller degree (range 0.40-0.99). The present results showed only moderate concordance of the majority of elastography machines with the Fibroscan results, preventing the possibility of the immediate universal adoption of Fibroscan thresholds for defining liver fibrosis staging for all new machines. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Concordance in Anti-OmpC and Anti-I2 Indicate the Influence of Genetic Predisposition: Results of a European Study of Twins with Crohn's Disease.

    PubMed

    Amcoff, Karin; Joossens, Marie; Pierik, Marie J; Jonkers, Daisy; Bohr, Johan; Joossens, Sofie; Romberg-Camps, Mariëlle; Nyhlin, Nils; Wickbom, Anna; Rutgeerts, Paul J; Tysk, Curt; Bodin, Lennart; Colombel, Jean-Frederic; Vermeire, Severine; Halfvarson, Jonas

    2016-06-01

    An adaptive immunological response to microbial antigens has been observed in Crohn's disease (CD). Intriguingly, this serological response precedes the diagnosis in some patients and has also been observed in healthy relatives. We aimed to determine whether genetic factors are implicated in this response in a CD twin cohort. In total, 82 twin pairs (Leuven n = 13, Maastricht n = 8, Örebro n = 61) took part: 81 pairs with CD (concordant monozygotic n = 16, discordant monozygotic n = 22, concordant dizygotic n = 3, discordant dizygotic n = 40) and 1 monozygotic pair with both CD and ulcerative colitis. Serology for Pseudomonas fluorescens-related protein (anti-I2), Escherichia coli outer membrane porin C (anti-OmpC), CBir1flagellin (anti-CBir1) and antibodies to oligomannan (anti-Saccharomyces cerevisiae antibody [ASCA]) was determined by standardized enzyme-linked immunoassay. All markers were more often present in CD twins than in their healthy twin siblings. Using the intraclass correlation coefficient (ICC), agreements in concentrations of anti-OmpC and anti-I2 were observed in discordant monozygotic but not in discordant dizygotic twin pairs with CD (anti-OmpC, ICC 0.80 and -0.02, respectively) and (anti-I2, ICC 0.56 and 0.05, respectively). In contrast, no agreements were found in anti-CBir, immunoglobulin (Ig) G ASCA and ASCA IgA. We show that anti-I2 and anti-CBir1 statuses have specificity for CD and confirm previous reported specificities for anti-OmpC and ASCA. Based on quantitative analyses and observed ICCs, genetics seems to predispose to the anti-OmpC and anti-I2 response but less to ASCA and anti-CBir1 responses. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Use of the ciliated protozoan Tetrahymena pyriformis for the assessment of toxicity and quantitative structure--activity relationships of xenobiotics: comparison with the Microtox test.

    PubMed

    Bogaerts, P; Bohatier, J; Bonnemoy, F

    2001-07-01

    Cytotoxicity and quantitative structure-activity relationships of 13 inorganic and 21 organic substances were determined using three bioassays performed on the ciliated protozoan Tetrahymena pyriformis and the luminescent bacterium Vibrio fischeri. The best concordance of toxicity results was observed between the T. pyriformis FDA--esterase activity and population growth inhibition tests for the organic compounds. The sensitivity of these two assays is compared with that of the Microtox test. The T. pyriformis FDA test showed a high sensitivity is most cases. The aim of the current research was to determine whether the relative toxicity of metal ions and organic molecules, with these three bioassays, was predictable using three ion characteristics and hydrophobicity, respectively. For metal ions, the variable that best modeled the toxicity data obtained with the two T. pyriformis tests was the softness index [sigma(p), i.e., (coordinate bond energy of the metal fluoride--coordinate bond energy of the metal iodide)/(coordinate bond energy of the metal fluoride)]. No correlation was found with the Microtox test. For organic compounds, a significant correlation was observed between the hydrophobicity coefficient and the toxicity data. This correlation is closer with the two tests using Tetrahymena. Copyright 2001 Academic Press.

  18. Patient-Generated Subjective Global Assessment of nutritional status in pediatric patients with recent cancer diagnosis.

    PubMed

    Vázquez de la Torre, Mayra Jezabel; Stein, Katja; Vásquez Garibay, Edgar Manuel; Kumazawa Ichikawa, Miguel Roberto; Troyo Sanromán, Rogelio; Salcedo Flores, Alicia Guadalupe; Sánchez Zubieta, Fernando Antonio

    2017-10-24

    The subjective global assessment (SGA) is a simple, sensitive tool used to identify nutritional risk. It is widely used in the adult population, but there is little evidence on its effectiveness in children with cancer. This cross-sectional study was undertaken to demonstrate significant correlation between a simplified version of the Patient-Generated SGA (PG-SGA) and anthropometric assessment to identify nutritional status in children recently diagnosed with cancer. The nutritional status of 70 pediatric cancer patients was assessed with the PG-SGA and anthropometric measurements. The relation between the assessments was tested with ANOVA, independent samples t-test, Kappa statistic, and non-parametric Spearman and Kendall correlation coefficient. The PG-SGA divided the patients into four groups: well nourished, mildly, moderately and severely malnourished. The prevalence of malnutrition according to the PG-SGA was 21.4%. The correlations (r ≥ 0.300, p < 0.001) and the concordance (k ≥ 0.327, p < 0.001) between the PG-SGA and anthropometric indicators were moderate and significant. The results indicate that the PG-SGA is a valid tool for assessing nutritional status in hospitalized children recently diagnosed with cancer. It is important to emphasize that the subjective assessment does not detect growth retardation, overweight or obesity.

  19. Investigations of the reliability of observational gait analysis for the assessment of lameness in horses.

    PubMed

    Hewetson, M; Christley, R M; Hunt, I D; Voute, L C

    2006-06-24

    The objectives of this study were to assess the reliability of a numerical rating scale (NRS) and a verbal rating scale (VRS) for the assessment of lameness in horses and to determine whether they can be used interchangeably. Sixteen independent observers graded the severity of lameness in 20 videotaped horses, and the agreement between and within observers, correlation and bias were determined for each scale. The observers agreed with each other in 56 per cent of the observations with the NRS and in 60 per cent of the observations with the VRS, and the associated Kendall coefficient of concordance was high. Similar trends were evident in the agreement between two observations by each observer. The correlation between and within observers was high for both scales. There were no significant differences (bias) among the observers' mean scores when using either scale. There was a significant correlation between the lameness scores attributed when using the two scales, but the differences between the scores when plotted against their overall mean were unacceptable for clinical purposes. The results indicate that the NRS and VRS are only moderately reliable when used to assess lameness severity in the horse, and that they should not be used interchangeably.

  20. Concordance of parent proxy report and child self-report of posttraumatic stress in children with cancer and healthy children: influence of parental posttraumatic stress.

    PubMed

    Clawson, Ashley H; Jurbergs, Niki; Lindwall, Jennifer; Phipps, Sean

    2013-11-01

    This study examined the relationships between parental posttraumatic stress symptoms (PTSS), child PTSS, and parent-child concordance for child PTSS. Participants were children with cancer (n = 199), and healthy children (n = 108) and their parents. Children self-reported on PTSS and parents completed measures of child and parent PTSS. In the cancer group, child and parent reports of child PTSS were significantly correlated with no mean differences between reporters. In contrast, correlations were non-significant in the control group, and parents reported significantly lower levels of child PTSS than children. Increased parental PTSS was associated with better concordance in the cancer group but not in the control group. In fact, in the cancer group, parent-child concordance was strongest at the highest level of parental PTSS. Parents of children with cancer were found to be accurate reporters of their children's distress, even with high levels of reported personal distress. In contrast, parents of healthy children appear primarily influenced by personal distress when reporting child PTSS. Although multiple informant assessments are always desirable, it appears that utilization of a single informant may be reasonable in the cancer setting when access to informants is limited. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Reliability and Validity of Two Self-report Measures to Assess Sedentary Behavior in Older Adults

    PubMed Central

    Gennuso, Keith P.; Matthews, Charles E.; Colbert, Lisa H.

    2015-01-01

    Background The purpose of this study was to examine the reliability and validity of two currently available physical activity surveys for assessing time spent in sedentary behavior (SB) in older adults. Methods Fifty-eight adults (≥65 years) completed the Yale Physical Activity Survey for Older Adults (YPAS) and Community Health Activities Model Program for Seniors (CHAMPS) before and after a 10-day period during which they wore an ActiGraph accelerometer (ACC). Intraclass correlation coefficients (ICC) examined test-retest reliability. Overall percent agreement and a kappa statistic examined YPAS validity. Lin’s concordance correlation, Pearson correlation, and Bland-Altman analysis examined CHAMPS validity. Results Both surveys had moderate test-retest reliability (ICC: YPAS=0.59 (P<0.001), CHAMPS=0.64 (P<0.001)) and significantly underestimated SB time. Agreement between YPAS and ACC was low (κ=−0.0003); however, there was a linear increase (P< 0.01) in ACC-derived SB time across YPAS response categories. There was poor agreement between ACC-derived SB and CHAMPS (Lin’s r=0.005; 95% CI, −0.010 to 0.020), and no linear trend across CHAMPS quartiles (p=0.53). Conclusions Neither of the surveys should be used as the sole measure of SB in a study; though the YPAS has the ability to rank individuals, providing it with some merit for use in correlational SB research. PMID:25110344

  2. Estimating individual glomerular volume in the human kidney: clinical perspectives.

    PubMed

    Puelles, Victor G; Zimanyi, Monika A; Samuel, Terence; Hughson, Michael D; Douglas-Denton, Rebecca N; Bertram, John F; Armitage, James A

    2012-05-01

    Measurement of individual glomerular volumes (IGV) has allowed the identification of drivers of glomerular hypertrophy in subjects without overt renal pathology. This study aims to highlight the relevance of IGV measurements with possible clinical implications and determine how many profiles must be measured in order to achieve stable size distribution estimates. We re-analysed 2250 IGV estimates obtained using the disector/Cavalieri method in 41 African and 34 Caucasian Americans. Pooled IGV analysis of mean and variance was conducted. Monte-Carlo (Jackknife) simulations determined the effect of the number of sampled glomeruli on mean IGV. Lin's concordance coefficient (R(C)), coefficient of variation (CV) and coefficient of error (CE) measured reliability. IGV mean and variance increased with overweight and hypertensive status. Superficial glomeruli were significantly smaller than juxtamedullary glomeruli in all subjects (P < 0.01), by race (P < 0.05) and in obese individuals (P < 0.01). Subjects with multiple chronic kidney disease (CKD) comorbidities showed significant increases in IGV mean and variability. Overall, mean IGV was particularly reliable with nine or more sampled glomeruli (R(C) > 0.95, <5% difference in CV and CE). These observations were not affected by a reduced sample size and did not disrupt the inverse linear correlation between mean IGV and estimated total glomerular number. Multiple comorbidities for CKD are associated with increased IGV mean and variance within subjects, including overweight, obesity and hypertension. Zonal selection and the number of sampled glomeruli do not represent drawbacks for future longitudinal biopsy-based studies of glomerular size and distribution.

  3. Is sexual concordance related to awareness of physiological states?

    PubMed

    Suschinsky, Kelly D; Lalumière, Martin L

    2012-02-01

    Sexual concordance refers to the degree to which two aspects of human sexual arousal (genital response and self-reported sexual arousal) correspond with each other. Researchers have consistently reported a sex difference in sexual concordance: The relationship between genital responses and reported feelings of sexual arousal in men is positive and large, whereas the relationship in women is positive but much smaller than that seen in men. The study of interoception--people's awareness of their physiological states--reveals a similar sex difference: Men are more aware of a variety of (non-genital) responses (e.g., heart rate) than women in the laboratory. The purpose of the current study was to investigate whether the sex difference in sexual concordance was related to a broader sex difference in interoception. Twenty men and 20 women were presented with twelve 90 s sexual and non-sexual film clips while their genital responses, heart rate, and respiration rate were measured. Participants also estimated their physiological responses. As expected, men were significantly more sexually concordant than women. Men were also significantly more aware of their heart rate, but there was no significant sex difference in respiration rate awareness. Sexual concordance was not significantly correlated with either heart rate or respiration rate awareness. The results suggest that the sex difference in sexual concordance may be a unique phenomenon, separate from general awareness of physiological states.

  4. Development of an automated analysis system for data from flow cytometric intracellular cytokine staining assays from clinical vaccine trials

    PubMed Central

    Shulman, Nick; Bellew, Matthew; Snelling, George; Carter, Donald; Huang, Yunda; Li, Hongli; Self, Steven G.; McElrath, M. Juliana; De Rosa, Stephen C.

    2008-01-01

    Background Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high throughput methods of data analysis. Methods A web based flow cytometric analysis system, LabKey Flow, was developed for analyses of data from standardized ICS assays. A gating template was created manually in commercially-available flow cytometric analysis software. Using this template, the system automatically compensated and analyzed all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Results Comparison of the semi-automated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient >0.990). Manual inspection of the analyses performed by LabKey Flow for 8-color ICS data files from several clinical vaccine trials indicates that template gates can appropriately be used for most data sets. Conclusions The semi-automated LabKey Flow analysis system can analyze accurately large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials. PMID:18615598

  5. MVisAGe Identifies Concordant and Discordant Genomic Alterations of Driver Genes in Squamous Tumors.

    PubMed

    Walter, Vonn; Du, Ying; Danilova, Ludmila; Hayward, Michele C; Hayes, D Neil

    2018-06-15

    Integrated analyses of multiple genomic datatypes are now common in cancer profiling studies. Such data present opportunities for numerous computational experiments, yet analytic pipelines are limited. Tools such as the cBioPortal and Regulome Explorer, although useful, are not easy to access programmatically or to implement locally. Here, we introduce the MVisAGe R package, which allows users to quantify gene-level associations between two genomic datatypes to investigate the effect of genomic alterations (e.g., DNA copy number changes on gene expression). Visualizing Pearson/Spearman correlation coefficients according to the genomic positions of the underlying genes provides a powerful yet novel tool for conducting exploratory analyses. We demonstrate its utility by analyzing three publicly available cancer datasets. Our approach highlights canonical oncogenes in chr11q13 that displayed the strongest associations between expression and copy number, including CCND1 and CTTN , genes not identified by copy number analysis in the primary reports. We demonstrate highly concordant usage of shared oncogenes on chr3q, yet strikingly diverse oncogene usage on chr11q as a function of HPV infection status. Regions of chr19 that display remarkable associations between methylation and gene expression were identified, as were previously unreported miRNA-gene expression associations that may contribute to the epithelial-to-mesenchymal transition. Significance: This study presents an important bioinformatics tool that will enable integrated analyses of multiple genomic datatypes. Cancer Res; 78(12); 3375-85. ©2018 AACR . ©2018 American Association for Cancer Research.

  6. Body surface assessment with 3D laser-based anthropometry: reliability, validation, and improvement of empirical surface formulae.

    PubMed

    Kuehnapfel, Andreas; Ahnert, Peter; Loeffler, Markus; Scholz, Markus

    2017-02-01

    Body surface area is a physiological quantity relevant for many medical applications. In clinical practice, it is determined by empirical formulae. 3D laser-based anthropometry provides an easy and effective way to measure body surface area but is not ubiquitously available. We used data from laser-based anthropometry from a population-based study to assess validity of published and commonly used empirical formulae. We performed a large population-based study on adults collecting classical anthropometric measurements and 3D body surface assessments (N = 1435). We determined reliability of the 3D body surface assessment and validity of 18 different empirical formulae proposed in the literature. The performance of these formulae is studied in subsets of sex and BMI. Finally, improvements of parameter settings of formulae and adjustments for sex and BMI were considered. 3D body surface measurements show excellent intra- and inter-rater reliability of 0.998 (overall concordance correlation coefficient, OCCC was used as measure of agreement). Empirical formulae of Fujimoto and Watanabe, Shuter and Aslani and Sendroy and Cecchini performed best with excellent concordance with OCCC > 0.949 even in subgroups of sex and BMI. Re-parametrization of formulae and adjustment for sex and BMI slightly improved results. In adults, 3D laser-based body surface assessment is a reliable alternative to estimation by empirical formulae. However, there are empirical formulae showing excellent results even in subgroups of sex and BMI with only little room for improvement.

  7. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    PubMed

    Dunet, Vincent; Klein, Ran; Allenbach, Gilles; Renaud, Jennifer; deKemp, Robert A; Prior, John O

    2016-06-01

    Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.

  8. Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Juan; School of Information Science and Engineering, Shandong University, Jinan, Shandong; Cai, Jing

    Purpose: To evaluate the relationship between liver tumor motion and diaphragm motion. Methods and Materials: Fourteen patients with hepatocellular carcinoma (10 of 14) or liver metastases (4 of 14) undergoing radiation therapy were included in this study. All patients underwent single-slice cine–magnetic resonance imaging simulations across the center of the tumor in 3 orthogonal planes. Tumor and diaphragm motion trajectories in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions were obtained using an in-house-developed normalized cross-correlation–based tracking technique. Agreement between the tumor and diaphragm motion was assessed by calculating phase difference percentage, intraclass correlation coefficient, and Bland-Altman analysis (Diff).more » The distance between the tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between the 2 motions. Results: Of all patients, the mean (±standard deviation) phase difference percentage values were 7.1% ± 1.1%, 4.5% ± 0.5%, and 17.5% ± 4.5% in the SI, AP, and ML directions, respectively. The mean intraclass correlation coefficient values were 0.98 ± 0.02, 0.97 ± 0.02, and 0.08 ± 0.06 in the SI, AP, and ML directions, respectively. The mean Diff values were 2.8 ± 1.4 mm, 2.4 ± 1.1 mm, and 2.2 ± 0.5 mm in the SI, AP, and ML directions, respectively. Tumor and diaphragm motions had high concordance when the distance between the tumor and tracked diaphragm area was small. Conclusions: This study showed that liver tumor motion had good correlation with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be used as a reliable surrogate for liver tumor motion.« less

  9. Evaluation of physiological strain in hot work areas using thermal imagery.

    PubMed

    Holm, Clint A; Pahler, Leon; Thiese, Matthew S; Handy, Rodney

    2016-10-01

    Monitoring core body temperature to identify heat strain in workers engaged in hot work in heat stress environments is intrusive and expensive. Nonintrusive, inexpensive methods are needed to calculate individual Physiological Strain Index (PSI). Thermal imaging and heart rate monitoring were used in this study to calculate Physiological Strain Index (PSI) from thermal imaging temperatures of human subjects wearing thermal protective garments during recovery from hot work. Ten male subjects were evaluated for physiological strain while participating in hot work. Thermal images of the head and neck were captured with a high-resolution thermal imaging camera concomitant with measures of gastrointestinal and skin temperature. Lin's concordance correlation coefficient (rho_c), Pearson's coefficient (r) and bias correction factor (C-b) were calculated to compare thermal imaging based temperatures to gastrointestinal temperatures. Calculations of PSI based thermal imaging recorded temperatures were compared to gastrointestinal based PSI. Participants reached a peak PSI of 5.2, indicating moderate heat strain. Sagittal measurements showed low correlation (rho_c=0.133), moderate precision (r=0.496) and low accuracy (C_b=0.269) with gastrointestinal temperature. Bland-Altman plots of imaging measurements showed increasing agreement as gastrointestinal temperature rose; however, the Limits of Agreement (LoA) fell outside the ±0.25C range of clinical significance. Bland-Altman plots of PSI calculated from imaging measurements showed increasing agreement as gastrointestinal temperature rose; however, the LoA fell outside the ±0.5 range of clinical significance. Results of this study confirmed previous research showing thermal imagery is not highly correlated to body core temperature during recovery from moderate heat strain in mild ambient conditions. Measurements display a trend toward increasing correlation at higher body core temperatures. Accuracy was not sufficient at mild to moderate heat strain to allow calculation of individual physiological stress. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Concordance of somatic mutational profile in multiple primary melanomas.

    PubMed

    Adler, Nikki R; McLean, Catriona A; Wolfe, Rory; Kelly, John W; McArthur, Grant A; Haydon, Andrew; Tra, Thien; Cummings, Nicholas; Mar, Victoria J

    2018-03-30

    This study aimed to determine the frequency and concordance of BRAF and NRAS mutation in tumours arising in patients with multiple primary melanoma (MPM). Patients with MPM managed at one of three tertiary referral centres in Melbourne, Australia, from 2010 to 2015 were included. Incident and subsequent melanomas underwent mutation testing. Cohen's kappa (κ) coefficient assessed agreement between incident and subsequent primary melanomas for both BRAF and NRAS mutation status (mutant versus wild-type). Mutation testing of at least two primary tumours from 64 patients was conducted. There was poor agreement for both BRAF and NRAS mutation status between incident and subsequent melanomas (κ = 0.10, 95% CI -0.10 to 0.42; κ = 0.06, 95% CI -0.10 to 0.57, respectively). In view of the low concordance in BRAF mutation status between incident and subsequent melanomas, mutational analysis of metastatic tissue, rather than of a primary melanoma, in patients with MPM should be used to guide targeted therapy. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Accuracy of arterial spin labeling magnetic resonance imaging (MRI) perfusion in detecting the epileptogenic zone in patients with drug-resistant neocortical epilepsy: comparison with electrophysiological data, structural MRI, SISCOM and FDG-PET.

    PubMed

    Sierra-Marcos, A; Carreño, M; Setoain, X; López-Rueda, A; Aparicio, J; Donaire, A; Bargalló, N

    2016-01-01

    Locating the epileptogenic zone (EZ) in patients with neocortical epilepsy presents major challenges. Our aim was to assess the accuracy of arterial spin labeling (ASL), an emerging non-invasive magnetic resonance imaging (MRI) perfusion technique, to locate the EZ in patients with drug-resistant neocortical epilepsy. Twenty-five consecutive patients with neocortical epilepsy referred to our epilepsy unit for pre-surgical evaluation underwent a standardized assessment including video-electroencephalography (EEG) monitoring, structural MRI, subtraction ictal single-photon emission computed tomography co-registered to MRI (SISCOM) and fluorodeoxyglucose positron emission tomography (FDG-PET) studies. An ASL sequence was included in the MRI studies. Areas of hypoperfusion or hyperperfusion on ASL were classified into 15 anatomic-functional cortical regions; these regional cerebral blood flow maps were compared with the EZ determined by the other tests and the strength of concordance was assessed with the kappa coefficient. Of the 25 patients [16 (64%) women; mean age 32.4 (±13.8) years], 18 (72%) had lesions on structural MRI. ASL abnormalities were seen in 15 (60%) patients (nine hypoperfusion, six hyperperfusion). ASL had a very good concordance with FDG-PET (k = 0.84), a good concordance with structural MRI (k = 0.76), a moderate concordance with video-EEG monitoring (k = 0.53) and a fair concordance with SISCOM (k = 0.28). Arterial spin labeling might help to confirm the location and extent of the EZ in the pre-surgical workup of patients with drug-resistant neocortical epilepsy. © 2015 EAN.

  12. Cross-cultural adaptation into Punjabi of the English version of the Hospital Anxiety and Depression Scale.

    PubMed

    Lane, Deirdre A; Jajoo, Jagdish; Taylor, Rod S; Lip, Gregory Yh; Jolly, Kate

    2007-01-26

    We wanted to use a Punjabi version of the Hospital Anxiety and Depression Scale (HADS) to enable non-English speaking patients to participate in a clinical trial. The aim of the study was to translate and validate the Hospital Anxiety and Depression Scale into Punjabi. The HADS was translated into Punjabi by a multidisciplinary team, verified against the original version, and administered to 73 bilingual patients attending an outpatient clinic. One sample t-tests and the Bland-Altman plots demonstrated acceptable linguistic agreement between the two versions of the HADS. Spearman's rank-order correlation coefficients (p < 0.0001) demonstrate excellent conceptual agreement between each item and its corresponding subscale score, for both versions. Concordance rates revealed that the Punjabi HADS adequately identified borderline cases of anxiety (80.8%), definite cases of anxiety (91.8%) and depression (91.8%), but was less reliable in identifying borderline cases of depression (65.8%). Cronbach alpha coefficients revealed high levels of internal consistency for both the Punjabi and English versions (0.81 and 0.86 for anxiety and 0.71 and 0.85 for depression, respectively). The Punjabi HADS is an acceptable, reliable and valid measure of anxiety and depression among physically ill Punjabi speaking people in the United Kingdom.

  13. Quantitative Contrast-Enhanced Ultrasound Parameters in Crohn Disease: Their Role in Disease Activity Determination With Ultrasound.

    PubMed

    Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R

    2016-01-01

    The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global assessment as the reference standard: using 18.2 dB to differentiate mild versus moderate activity yielded sensitivity of 89.2% and specificity of 90.9% and using 22.9 dB to differentiate moderate versus severe activity yielded sensitivity of 89.5% and specificity of 83.1%. Quantitative CEUS parameters integrated into inflammatory assessments with ultrasound reduce indeterminate results and improve disease activity level determinations.

  14. Statistical Package User’s Guide.

    DTIC Science & Technology

    1980-08-01

    261 C. STACH Nonparametric Descriptive Statistics ... ......... ... 265 D. CHIRA Coefficient of Concordance...135 I.- -a - - W 7- Test Data: This program was tested using data from John Neter and William Wasserman, Applied Linear Statistical Models: Regression...length of data file e. new fileý name (not same as raw data file) 5. Printout as optioned for only. Comments: Ranked data are used for program CHIRA

  15. Interoception and sexual response in women with low sexual desire

    PubMed Central

    Velten, Julia

    2017-01-01

    Sexual concordance is defined as the association between genital response and self-reported sexual arousal. Though one might predict a strong association between sexual concordance and awareness of other internal physiological sensations (termed interoception), past research on sexually healthy women has not found these different domains to be related. The aim of the present study was to test the association between interoception and sexual concordance in a clinical sample of women with Sexual Interest/Arousal Disorder (SIAD). Fifty-two women with SIAD completed the Multidimensional Assessment of Interoceptive Awareness (MAIA), a validated self-report measure of interoception, and completed a heart-beat accuracy test, an objective measure of interoception. They also participated in a laboratory-based assessment of physiological sexual arousal and self-reported sexual arousal while viewing an erotic film. Mental and physiological arousal were correlated at r = 0.27 (range -0.80 to 0.95). There was no significant association between sexual concordance and women’s heartrate awareness. However, five aspects of interoceptive awareness (noticing, emotional awareness, self-regulation, body-listening, and trusting), were predictive of lower, and one aspect (not-distracting) was predictive of higher sexual concordance. We discuss the findings in relation to the role of emotions and arousal states in the interoception-sexual concordance relationship. PMID:29020067

  16. Interoception and sexual response in women with low sexual desire.

    PubMed

    Velten, Julia; Brotto, Lori A

    2017-01-01

    Sexual concordance is defined as the association between genital response and self-reported sexual arousal. Though one might predict a strong association between sexual concordance and awareness of other internal physiological sensations (termed interoception), past research on sexually healthy women has not found these different domains to be related. The aim of the present study was to test the association between interoception and sexual concordance in a clinical sample of women with Sexual Interest/Arousal Disorder (SIAD). Fifty-two women with SIAD completed the Multidimensional Assessment of Interoceptive Awareness (MAIA), a validated self-report measure of interoception, and completed a heart-beat accuracy test, an objective measure of interoception. They also participated in a laboratory-based assessment of physiological sexual arousal and self-reported sexual arousal while viewing an erotic film. Mental and physiological arousal were correlated at r = 0.27 (range -0.80 to 0.95). There was no significant association between sexual concordance and women's heartrate awareness. However, five aspects of interoceptive awareness (noticing, emotional awareness, self-regulation, body-listening, and trusting), were predictive of lower, and one aspect (not-distracting) was predictive of higher sexual concordance. We discuss the findings in relation to the role of emotions and arousal states in the interoception-sexual concordance relationship.

  17. Correlates of and Couples’ Concordance in Reports of Recent Sexual Behavior and Contraceptive Use

    PubMed Central

    Koffi, Alain K.; Adjiwanou, Visseho D.; Becker, Stan; Olaolorun, Funmilola; Tsui, Amy O.

    2014-01-01

    This study uses couple-level data to measure couples’ concordance of self-reported time since last coitus and of condom and other contraceptive use at last sexual intercourse among monogamous couples in Liberia (N = 1,673), Madagascar (N = 4,138), and Namibia (N = 588). The study also examines the characteristics associated with sexual behavior and contraceptive use occurring in the 28 days prior to the interviews among couples whose reports are concordant. Overall, our study finds less than 75 percent concordance in reporting of time since last coitus. Use of condoms and other contraceptives yielded fair (0.27) to substantial (0.67) agreement on the kappa index. Factors predicting a shorter time since last coitus among concordant couples in at least two of the countries included wealth, spousal age difference, education, and both partners wanting another child. The discordant reports of recent sexual behavior and contraceptive use suggest that caution should be exercised when inferring couples’ behavior from the report of one spouse, that concordant reports should be examined when possible, that methodological changes to improve the validity of spousal reports should be pursued, and that family planning and HIV-prevention programs should target those groups found to be using condoms and other contraceptives less frequently, particularly poorer couples. PMID:23185870

  18. Correlates of and couples' concordance in reports of recent sexual behavior and contraceptive use.

    PubMed

    Koffi, Alain K; Adjiwanou, Visseho D; Becker, Stan; Olaolorun, Funmilola; Tsui, Amy O

    2012-03-01

    This study uses couple-level data to measure couples' concordance of self-reported time since last coitus and of condom and other contraceptive use at last sexual intercourse among monogamous couples in Liberia (N = 1,673), Madagascar (N = 4,138), and Namibia (N = 588). The study also examines the characteristics associated with sexual behavior and contraceptive use occurring in the 28 days prior to the interviews among couples whose reports are concordant. Overall, our study finds less than 75 percent concordance in reporting of time since last coitus. Use of condoms and other contraceptives yielded fair (0.27) to substantial (0.67) agreement on the kappa index. Factors predicting a shorter time since last coitus among concordant couples in at least two of the countries included wealth, spousal age difference, education, and both partners wanting another child. The discordant reports of recent sexual behavior and contraceptive use suggest that caution should be exercised when inferring couples' behavior from the report of one spouse, that concordant reports should be examined when possible, that methodological changes to improve the validity of spousal reports should be pursued, and that family planning and HIV-prevention programs should target those groups found to be using condoms and other contraceptives less frequently, particularly poorer couples.

  19. Predictors of health literacy and numeracy concordance among adolescent with special health care needs and their parents

    PubMed Central

    Chisolm, Deena J; Sarkar, Madhurima; Kelleher, Kelly J.; Sanders, Lee M.

    2015-01-01

    Background Parent and teen health literacies (HL) are employed as teens with chronic illnesses transition to health self-management and the adult health system. This study explores the relationships between parent and teen HL. Methods Teens ages 12-18 with chronic conditions and their parents, sampled from a pediatric Medicaid ACO, completed an interview assessing HL and self-reported competence with written and numeric health information. Rates of teen and parent HL, degree of concordance, and relationship between concordance and teen-reported competence with health materials were measured. Results Half (52%) of teens had adequate HL. 62% of teens reported competence with written health materials and 69% with numeric information. Correlation between parent and teen HL was modest but significant (phi=0.13; p=0.03). 47% of parent-teen dyads were concordant for adequate HL while 10% were concordant inadequate. Adequate teen HL was associated with parental adequate HL and parental education. Discordance was associated with self-reported competence with written material and numeric material. Conclusion Over half of parent-teen dyads had at least one member with less than adequate health literacy and parent-teen HL concordance were associated with teen perception of health literacy. These findings support the consideration of both independent and dyad HL levels in adolescent care. PMID:26513030

  20. Standardization of the capillary electrophoresis procedures Capillarys® CDT and Minicap® CDT in comparison to the IFCC reference measurement procedure.

    PubMed

    Schellenberg, François; Humeau, Camille

    2017-06-01

    CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.

  1. Development and evaluation of an audiology app for iPhone/iPad mobile devices.

    PubMed

    Larrosa, Francisco; Rama-Lopez, Julio; Benitez, Jesus; Morales, Jose M; Martinez, Asuncion; Alañon, Miguel A; Arancibia-Tagle, Diego; Batuecas-Caletrio, Angel; Martinez-Lopez, Marta; Perez-Fernandez, Nicolas; Gimeno, Carlos; Ispizua, Angel; Urrutikoetxea, Alberto; Rey-Martinez, Jorge

    2015-01-01

    The application described in this study appears to be accurate and valid, thus allowing calculation of a hearing handicap and assessment of the pure-tone air conduction threshold with iPhone/iPad devices. To develop and evaluate a newly developed professional, computer-based hearing handicap calculator and a manual hearing sensitivity assessment test for the iPhone and iPad (AudCal). Multi-center prospective non-randomized validation study. One hundred and ten consecutive adult participants underwent two hearing evaluations, a standard audiometry and a pure-tone air conduction test using AudCal with an iOS device. The hearing handicap calculation accuracy was evaluated comparing AudCal vs a web-based calculator. Hearing loss was found in 83 and 84 out of 220 standard audiometries and AudCal hearing tests (Cohen's Kappa = 0.89). The mean difference between AudCal and standard audiogram thresholds was -0.21 ± 6.38 dB HL. Excellent reliability and concordance between standard audiometry and the application's hearing loss assessment test were obtained (Cronbach's alpha = 0.96; intra-class correlation coefficient = 0.93). AudCal vs a web-based calculator were perfectly correlated (Pearson's r = 1).

  2. Reliability and validity of selected measures associated with increased fall risk in females over the age of 45 years with distal radius fracture - A pilot study.

    PubMed

    Mehta, Saurabh P; MacDermid, Joy C; Richardson, Julie; MacIntyre, Norma J; Grewal, Ruby

    2015-01-01

    Clinical measurement. This study examined test-retest reliability and convergent/divergent construct validity of selected tests and measures that assess balance impairment, fear of falling (FOF), impaired physical activity (PA), and lower extremity muscle strength (LEMS) in females >45 years of age after the distal radius fracture (DRF) population. Twenty one female participants with DRF were assessed on two occasions. Timed Up and Go, Functional Reach, and One Leg Standing tests assessed balance impairment. Shortened Falls Efficacy Scale, Activity-specific Balance Confidence scale, and Fall Risk Perception Questionnaire assessed FOF. International Physical Activity Questionnaire and Rapid Assessment of Physical Activity were administered to assess PA level. Chair stand test and isometric muscle strength testing for hip and knee assessed LEMS. Intraclass correlation coefficients (ICC) examined the test-retest reliability of the measures. Pearson correlation coefficients (r) examined concurrent relationships between the measures. The results demonstrated fair to excellent test-retest reliability (ICC between 0.50 and 0.96) and low to moderate concordance between the measures (low if r ≤ 0.4; moderate if r = 0.4-0.7). The results provide preliminary estimates of test-retest reliability and convergent/divergent construct validity of selected measures associated with increased risk for falling in the females >45 years of age after DRF. Further research directions to advance knowledge regarding fall risk assessment in DRF population have been identified. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  3. Convergence of scores on the interview and questionnaire versions of the Eating Disorder Examination: a meta-analytic review.

    PubMed

    Berg, Kelly C; Peterson, Carol B; Frazier, Patricia; Crow, Scott J

    2011-09-01

    Significant discrepancies have been found between interview- and questionnaire-based assessments of psychopathology; however, these studies have typically compared instruments with unmatched item content. The Eating Disorder Examination (EDE), a structured interview, and the questionnaire version of the EDE (EDE-Q) are considered the preeminent assessments of eating disorder symptoms and provide a unique opportunity to examine the concordance of interview- and questionnaire-based instruments with matched item content. The convergence of EDE and EDE-Q scores has been examined previously; however, past studies have been limited by small sample sizes and have not compared the convergence of scores across diagnostic groups. A meta-analysis of 16 studies was conducted to compare the convergence of EDE and EDE-Q scores across studies and diagnostic groups. With regard to the EDE and EDE-Q subscale scores, the overall correlation coefficient effect sizes ranged from .68 to .76. The overall Cohen's d effect sizes ranged from .31 to .62, with participants consistently scoring higher on the questionnaire. For the items measuring behavior frequency, the overall correlation coefficient effect sizes ranged from .37 to .55 for binge eating and .90 to .92 for compensatory behaviors. The overall Cohen's d effect sizes ranged from -0.16 to -0.22, with participants reporting more binge eating on the interview than in the questionnaire in 70% of the studies. These results suggest the interview and questionnaire assess similar constructs but should not be used interchangeably. Additional research is needed to examine the inconsistencies between binge frequency scores on the 2 instruments.

  4. A Simple and Easy Process for the Determination of Estimated Plasma Glucose Level in Patients Presenting to Hospital: An Example of Multicentric Data Mining.

    PubMed

    Serdar, Muhittin A; Koldaş, Macit; Serteser, Mustafa; Akın, Okhan; Sonmez, Cigdem; Gülbahar, Ozlem; Akbıyık, Filiz; Ünsal, Ibrahim

    2016-12-01

    The aim of the present study was to determine the relation between the simultaneous fasting plasma glucose level and HbA1c in a large population of patients presenting to the hospital, based on various measurement methods available for HbA1c. HbA1c levels of 162,210 patients presenting to various hospitals and laboratories were measured based on seven different systems, and at the same time, eAG levels were calculated based on HbA1c levels. The correlation coefficients (r) between serum plasma glucose and HbA1c levels were found to be 0.809, 0.774, 0.779, 0.817, 0.704, 0.796, and 0.747 in Bio-Rad Variant II, Tosoh G8, ADAMS A1c, Trinity Boronate Affinity, Chromsystems HPLC, Roche Tina-quant, and Abbott Architect, respectively. The concordance correlation coefficients between the eAG levels as calculated with the formulas provided in the text and the eAG levels as calculated according to NGSP directions (where eAG = (28.7*HbA1c) - 46.7) were found to be between 0.9339 and 0.9866. Despite the progress made for the standardization of HbA1c measurements, the relation between serum glucose and HbA1c still demonstrated certain discrepancies pertaining to the differences in measurement methodologies. As a conclusion, each laboratory could determine different eAG levels depending on the data originated by their individual analyzer. © 2016 Society for Laboratory Automation and Screening.

  5. Evaluation of the coagulometer STA R Max® (Stago) for routine coagulation parameters.

    PubMed

    Brulé, Justine; Sinegre, Thomas; Pereira, Bruno; Berger, Marc G; Serre-Sapin, Anne-Françoise; Lebreton, Aurélien

    2018-04-01

    The STA R Max ® is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max ® is equipped with an innovative software (STA Coag Expert ® ) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max ® analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.

  6. An in vitro human skin test for assessing sensitization potential.

    PubMed

    Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M

    2016-05-01

    Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.

  7. A simple method of measuring tibial tubercle to trochlear groove distance on MRI: description of a novel and reliable technique.

    PubMed

    Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J

    2016-03-01

    Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.

  8. A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.

    PubMed

    Meislin, Megan A; Wagner, Eric R; Shin, Alexander Y

    2016-04-01

    The purpose of this study was to validate elbow flexion and extension measured from smartphone photography obtained by participants and compared them with photographs obtained by surgeons and goniometric measurements. We enrolled 32 participants with a total of 64 elbows, aged 25 to 68 years. Participants obtained smartphone photographs of full elbow flexion and extension. Then surgeons obtained the same photographs and goniometric measurement of elbow range of motion (ROM). We measured ROM from the photographs using Adobe Photoshop and calculated average ROM. Comparisons of manual goniometer versus digital measurements, participant versus surgeon photograph measurements, and interobserver measurements were statistically analyzed. Average ROM measured by manual goniometer and digital photographs was 0° to 129° (range, 0° to 140°) and 0° to 129° (range, 0° to 145°), respectively. The goniometer versus digital measurements interclass correlation was 0.828 (L) and 0.740 (R). Pearson coefficient was 0.845 (L) and 0.757 (R). Bland-Altman plots demonstrated that 30 of 32 digital measurements (L) and 31 of 32 measurements (R) were within the 95% confidence interval. Participant-obtained photographs compared with researcher's photographs interclass correlation was 0.955 (L) and 0.941 (R), with a Pearson coefficient of 0.962 (L) and 0.957 (R), respectively. Reviewing interobserver reliability, concordance coefficients were 0.793 (L) and 0.767 (R) and Pearson coefficients were 0.811 (L) and 0.780 (R). Bland-Altman plots demonstrated that 28 of 32 digital measurements (L) and 26 of 32 measurements (R) were within the 95% confidence interval. Measuring elbow ROM using smartphone digital photography is valid and reliable. Participants were able to obtain accurate photographs and the measurements based on these photographs show no statistical difference from those taken by surgeons or goniometric measurement. This study validates using smartphone photography for measuring elbow ROM by laymen in a remote setting. Diagnostic II. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.

    PubMed

    Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues

    2014-07-01

    This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.

  10. Diagnosis of bacterial ventilator-associated pneumonia in children: reproducibility of blind bronchial sampling.

    PubMed

    Sachdev, Anil; Chugh, Krishan; Raghunathan, Veena; Gupta, Dhiren; Wattal, Chand; Menon, Geetha R

    2013-01-01

    To evaluate the reproducibility of blind bronchial sampling in patients with suspected diagnosis of bacterial ventilator-associated pneumonia. Prospective study. Pediatric intensive care unit of a tertiary care, multidisciplinary, teaching hospital in Northern India. All consecutive patients on mechanical ventilation for >48 hrs were evaluated clinically for ventilator-associated pneumonia. Children with clinical ventilator-associated pneumonia were subjected to blind bronchial sampling twice. Sixty-eight blind bronchial sampling samples from 34 patients were analyzed for polymorphonuclear cells, the presence, type, and number of bacteria. Acinetobacter baumannii was the most common organism grown from distal respiratory secretions. For polymorphonuclear cells, the concordance between two blind bronchial samples was 85.3% and kappa coefficient was 0.65. The concordance for the presence and type of bacteria in Gram staining in two samples was 85.3% and kappa coefficient was 0.68. The intraclass coefficients for bacterial index and predominant species index were 0.82 (95% confidence interval 0.65-0.91) and 0.89 (95% confidence interval 0.78-0.94), respectively. The use of prior antibiotics did not adversely affect the reproducibility of blind bronchial sampling. No major complications were recorded during the procedure. Blind bronchial sampling of lower respiratory tract secretions in mechanically ventilated patients generates reproducible results of quantitative and qualitative cultures. We suggest that blind bronchial sampling may provide valuable clue to the bacterial etiology in ventilated child with suspected clinical ventilator-associated pneumonia.

  11. A report on the clinical-pathological correlations of 788 gingival lesion

    PubMed Central

    Carbone, Mario; Broccoletti, Roberto; Carcieri, Paola; Conrotto, Davide; Carrozzo, Marco; Arduino, Paolo G.

    2017-01-01

    Background The diagnosis and treatment of a variety of non-plaque related gingival diseases have become an integrated aspect of everyday dentistry. The aim of this study was to analyse the relationship between clinical appearance and histopathological features of gingival lesions in a large Northern Italian population. Material and Methods A retrospective study of 788 cases of gingival and alveolar mucosal biopsies was set up. Statistical analysis was performed by calculating the odds ratio and 95% confidence interval (C.I.), in order to assess the degree of association between the clinical parameters considered (primary lesions) and the single pathologies, statistically evaluated by Mantel-Haenszel tests. The correlation between clinical and histological diagnosis was classified as follow: 1) expected data (ED): provisional clinical diagnosis; 2) real data (RD): final histopathology diagnosis; 3) concordant data (CD): correspondence between the expected data and real data. The correlation was calculated as follow: CC (complete concordance) = CD x 100 / ED, this expressing the percentage in which the clinical and the histological diagnosis overlapped. Results The most frequently observed and biopsied primary lesions resulted to be exophytic, followed by mucosal colour changes and finally by losses of substance. The statistically significant association between primary lesion and their manifestation in gingival pathologies was reported. Volume increases, for instance, were positively correlated to plasma cell epulis, pyogenic granuloma, fibrous reactive hyperplasia and hemangioma. Verrucous-papillary lesions were most often seen in verrucous carcinoma, verrucous leukoplakia and mild dysplasia. White lesion resulted to be related to leukoplakia or oral lichen planus. Red lesions resulted to be related only oral lichen planus. Erosive vesicle-bullous lesions were linked to disimmune pathologies. Ulcerative lesions were positively associated to oral squamous cell cancer. Finally, potentially malignant disorders have the most percentage high concordance. Among the malignant lesions, the correlation increased up to the squamous cell carcinoma and leukaemia. Conclusions This article presented the frequency and the clinico-pathological concordance of all primary lesions and the histopathological diagnosis of gingival lesions. For every primary lesion, it is possible to correlate a specific histopathological diagnosis in a statistical manner. This can be a valuable aid for not specialist clinicians who daily observe mucosae and have the opportunity to intercept major diseases. Key words:Gingival lesions; clinical appearance; histological analysis; clinico-pathological correlation. PMID:29053652

  12. Reliability of shear wave ultrasound elastography for neck lesions identified in routine clinical practice.

    PubMed

    Bhatia, K; Tong, C S L; Cho, C C M; Yuen, E H Y; Lee, J; Ahuja, A T

    2012-10-01

    To evaluate the reliability of shear wave ultrasound elastography (SWE) in the neck. 176 neck lesions (40 thyroid, 56 lymph nodes, 46 salivary, 34 miscellaneous) identified in a routine US clinic underwent SWE by one or two blinded radiologists. For this study, SWE required the operator to acquire three 10 second dynamic colour-coded SWE cineloops per lesion, select one static image per cineloop, and place circular regions-of-interest within the entire lesion and stiffest part to generate 3 SWE measurements per static image. For logistical reasons, one radiologist evaluated all 176 lesions and the other evaluated 58 lesions. Both radiologists also reviewed 27 archived cineloops independently to assess SWE excluding practical technique. Reliability was assessed using intraclass correlation coefficients (ICCs) concordance correlation coefficients (CCCs) and coefficients of repeatability (CORs). Test-retest ICCs for the radiologist evaluating 176 lesions were 0.78 - 0.85 (fair-excellent agreement), CCCs were 0.85 - 0.88 (substantial agreement), and CORs were 14.9 - 36.1 kPa. For both radiologists evaluating 58 lesions, intra-rater and inter-rater ICCs were 0.65 - 0.78 and 0.72 - 0.77 respectively. For SWE excluding practical technique, inter-rater ICCs were 0.97 - 0.98 (excellent agreement). ICCs differed according to tissue, being higher in thyroid lesions than lymph nodes (p < 0.001), and higher in benign than malignant lesions (p values < 0.001). Intra- and inter-rater reliability of SWE is fair to excellent according to ICCs. SWE reliability is influenced appreciably by acquisition technique. Nevertheless, CORs for SWE are not negligible. To determine whether these results are acceptable clinically, further research is required to establish SWE stiffness values of normal and pathological tissues in the neck. © Georg Thieme Verlag KG Stuttgart · New York.

  13. The premature ejaculation diagnostic tool (PEDT): linguistic validity of the Chinese version.

    PubMed

    Huang, Yan-Ping; Chen, Bin; Ping, Ping; Wang, Hong-Xiang; Hu, Kai; Zhang, Tao; Yang, Hao; Jin, Yan; Yang, Qi; Huang, Yi-Ran

    2014-09-01

    The premature ejaculation diagnostic tool (PEDT) was developed to standardize the diagnosis of PE and has been applied in many countries. However, a linguistic validation of the Chinese version of PEDT does not exist. This study aims to undertake the Chinese validation of the PEDT and to evaluate its association with self-estimated intravaginal ejaculatory latency time (IELT) and clinical expert diagnosis of PE. A Chinese version of PEDT was confirmed by andrologist and bilingual linguist. Participants were recruited among seven different communities of Shanghai from 2011 to 2012, and their information regarding self-reported PE, self-estimated IELT, expert diagnosis of PE, and PEDT scores were collected. Validity of the PEDT and its association with clinical expert diagnosis of PE and self-estimated IELT were analyzed. A total of 143 patients without PE (mean age 55.11 ± 7.65 years) and 100 men with PE (mean age 53.07 ± 8.08 years) were enrolled for validation. Of the patients in PE group, the number of men reporting self-estimated IELTs of ≤1, 1-2, and >2 minutes were 34 (34.0%), 22 (22.0%), and 44 (44.0%), respectively. The Cronbach's alpha score (α = 0.77) showed adequate internal consistency, and the test-retest correlation coefficients of each item (r ≥ 0.70, P < 0.001) indicated excellent stability over time. The frequency of agreement showed that there was excellent concordance between PEDT diagnosis and clinician diagnosis when the PEDT scores ≥11. An adequate correlation was found between total PEDT score and self-estimated IELT (ρ = -0.396, P < 0.001), and sensitivity and specificity analyses suggested a score of ≤8 indicated no time-defined PE (self-estimated IELT ≤1 minute). The Chinese version of PEDT is valid in screening the presence of PE among Chinese men. The PEDT showed an adequate negative correlation with self-estimated IELT and an excellent concordance with clinician diagnosis of PE. © 2014 International Society for Sexual Medicine.

  14. Analytical and clinical evaluation of the new Fujirebio Lumipulse®G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patients.

    PubMed

    Cavalier, Etienne; Lukas, Pierre; Bekaert, Anne-Catherine; Peeters, Stéphanie; Le Goff, Caroline; Yayo, Eric; Delanaye, Pierre; Souberbielle, Jean-Claude

    2016-08-01

    In this study, we provide a short analytical evaluation of the new Fujirebio Lumipulse®G non-competitive immunoassay for 25(OH)D. Clinical performance was compared with three commercial competitive automated immunoassays against a Vitamin D Standardization Program (VDSP)-traceable liquid chromatography-tandem mass spectrometry (LC-MS/MS) in six different clinically relevant populations. Lumipulse®G 25(OH)D precision, measurement uncertainty, recovery, limit of quantification were assessed, as well as 25(OH)D2 and C3-epimer recovery. For method comparison, 250 serum samples obtained in healthy Caucasians and Africans, osteoporotic, hemodialyzed and intensive care patients and 3rd trimester pregnant women were analyzed by all methods. Correlation was studied using Passing-Bablok and Bland-Altman analysis. Concordance correlation coefficient (CCC) was calculated to evaluate agreement between immunoassays and the LC-MS/MS. The Lumipulse®G 25(OH)D assay presented interesting analytical features and showed excellent correlation to the LC-MS/MS results (y=1.00×-1.35 ng/mL), as obtained in healthy Caucasian individuals. In the other special populations, Lumipulse®G presented a concordance with LC-MS/MS which was generally higher than competitors, even if all methods significantly under-recovered 25(OH)D in hemodialyzed patients. Intra-assay CV ranged from 12.1% at 9.6 ng/mL to 2.1% at 103.7 ng/mL and inter-assay CV ranged from 16.2 to 3.7% at the same concentrations, respectively. Measurement uncertainty, with a probability of 95%, were respectively 33.1 and 7.6% at these concentrations. LOQ was found to be at 4.6 ng/mL. Mean (95% CI) 25(OH)D2 revovery was 77% (74-81) and no cross-reactivity was observed with C3-epimer. Fujirebio Lumipulse®G 25-OH Vitamin D Total assay is therefore considered suitable for assessment of vitamin D status in clinical routine.

  15. Micro-scale Spatial Clustering of Cholera Risk Factors in Urban Bangladesh

    PubMed Central

    Bi, Qifang; Azman, Andrew S.; Satter, Syed Moinuddin; Khan, Azharul Islam; Ahmed, Dilruba; Riaj, Altaf Ahmed; Gurley, Emily S.; Lessler, Justin

    2016-01-01

    Close interpersonal contact likely drives spatial clustering of cases of cholera and diarrhea, but spatial clustering of risk factors may also drive this pattern. Few studies have focused specifically on how exposures for disease cluster at small spatial scales. Improving our understanding of the micro-scale clustering of risk factors for cholera may help to target interventions and power studies with cluster designs. We selected sets of spatially matched households (matched-sets) near cholera case households between April and October 2013 in a cholera endemic urban neighborhood of Tongi Township in Bangladesh. We collected data on exposures to suspected cholera risk factors at the household and individual level. We used intra-class correlation coefficients (ICCs) to characterize clustering of exposures within matched-sets and households, and assessed if clustering depended on the geographical extent of the matched-sets. Clustering over larger spatial scales was explored by assessing the relationship between matched-sets. We also explored whether different exposures tended to appear together in individuals, households, and matched-sets. Household level exposures, including: drinking municipal supplied water (ICC = 0.97, 95%CI = 0.96, 0.98), type of latrine (ICC = 0.88, 95%CI = 0.71, 1.00), and intermittent access to drinking water (ICC = 0.96, 95%CI = 0.87, 1.00) exhibited strong clustering within matched-sets. As the geographic extent of matched-sets increased, the concordance of exposures within matched-sets decreased. Concordance between matched-sets of exposures related to water supply was elevated at distances of up to approximately 400 meters. Household level hygiene practices were correlated with infrastructure shown to increase cholera risk. Co-occurrence of different individual level exposures appeared to mostly reflect the differing domestic roles of study participants. Strong spatial clustering of exposures at a small spatial scale in a cholera endemic population suggests a possible role for highly targeted interventions. Studies with cluster designs in areas with strong spatial clustering of exposures should increase sample size to account for the correlation of these exposures. PMID:26866926

  16. Reproducible automated breast density measure with no ionizing radiation using fat-water decomposition MRI.

    PubMed

    Ding, Jie; Stopeck, Alison T; Gao, Yi; Marron, Marilyn T; Wertheim, Betsy C; Altbach, Maria I; Galons, Jean-Philippe; Roe, Denise J; Wang, Fang; Maskarinec, Gertraud; Thomson, Cynthia A; Thompson, Patricia A; Huang, Chuan

    2018-04-06

    Increased breast density is a significant independent risk factor for breast cancer, and recent studies show that this risk is modifiable. Hence, breast density measures sensitive to small changes are desired. Utilizing fat-water decomposition MRI, we propose an automated, reproducible breast density measurement, which is nonionizing and directly comparable to mammographic density (MD). Retrospective study. The study included two sample sets of breast cancer patients enrolled in a clinical trial, for concordance analysis with MD (40 patients) and reproducibility analysis (10 patients). The majority of MRI scans (59 scans) were performed with a 1.5T GE Signa scanner using radial IDEAL-GRASE sequence, while the remaining (seven scans) were performed with a 3T Siemens Skyra using 3D Cartesian 6-echo GRE sequence with a similar fat-water separation technique. After automated breast segmentation, breast density was calculated using FraGW, a new measure developed to reliably reflect the amount of fibroglandular tissue and total water content in the entire breast. Based on its concordance with MD, FraGW was calibrated to MR-based breast density (MRD) to be comparable to MD. A previous breast density measurement, Fra80-the ratio of breast voxels with <80% fat fraction-was also calculated for comparison with FraGW. Pearson correlation was performed between MD (reference standard) and FraGW (and Fra80). Test-retest reproducibility of MRD was evaluated using the difference between test-retest measures (Δ 1-2 ) and intraclass correlation coefficient (ICC). Both FraGW and Fra80 were strongly correlated with MD (Pearson ρ: 0.96 vs. 0.90, both P < 0.0001). MRD converted from FraGW showed higher test-retest reproducibility (Δ 1-2 variation: 1.1% ± 1.2%; ICC: 0.99) compared to MD itself (literature intrareader ICC ≤0.96) and Fra80. The proposed MRD is directly comparable with MD and highly reproducible, which enables the early detection of small breast density changes and treatment response. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  17. Hallux Valgus, By Nature or Nurture? A Twin Study.

    PubMed

    Munteanu, Shannon E; Menz, Hylton B; Wark, John D; Christie, Jemma J; Scurrah, Katrina J; Bui, Minh; Erbas, Bircan; Hopper, John L; Wluka, Anita E

    2017-09-01

    To evaluate the contributions of shared but unmeasured genetic and environmental factors to hallux valgus (HV). Between 2011 and 2012, 74 monozygotic (MZ) and 56 dizygotic (DZ) female twin pairs self-reported HV and putative risk factors, including footwear use across their lifespan. Estimates of casewise concordance (P C ), correlation (ρ), and odds ratios (ORs) were calculated, adjusting for age and other risk factors, and compared between MZ and DZ pairs using logistic regression, generalized estimating equations, and a maximum likelihood-based method, respectively. A total of 70 participants (27%) reported HV, with 12 MZ and 7 DZ pairs being concordant. After adjusting for age, twins were correlated (ρ = 0.27 [95% confidence interval (95% CI) 0.08, 0.46]) and concordant (P C  = 0.45 [95% CI 0.29, 0.61]; mean age 58 years), with no difference between MZ and DZ pairs (P = 0.7). HV was associated with regularly wearing footwear with a constrictive toe-box during the fourth decade (adjusted OR 2.73 [95% CI 1.12, 6.67]). This risk factor was correlated in MZ (ρ = 0.38 [95% CI 0.15, 0.60]) but not DZ (ρ = -0.20 [95% CI -0.43, 0.03]) pairs. These correlations were significantly different (P = 0.002). Twins are correlated for HV, but we found no evidence that correlation was due to shared genetic factors. We identified an environmental risk factor, footwear with a constrictive toe-box, that is not shared to the same extent by MZ and DZ pairs, contrary to the assumption of the classic twin model. Footwear, and possibly genetic factors and unknown shared environmental factors, could contribute to developing HV. © 2016, American College of Rheumatology.

  18. Quantitative measurement of HER2 expression in breast cancers: comparison with 'real-world' routine HER2 testing in a multicenter Collaborative Biomarker Study and correlation with overall survival.

    PubMed

    Yardley, Denise A; Kaufman, Peter A; Huang, Weidong; Krekow, Lea; Savin, Michael; Lawler, William E; Zrada, Stephen; Starr, Alexander; Einhorn, Harvey; Schwartzberg, Lee S; Adams, John W; Lie, Yolanda; Paquet, Agnes C; Sperinde, Jeff; Haddad, Mojgan; Anderson, Steve; Brigino, Marlon; Pesano, Rick; Bates, Michael P; Weidler, Jodi; Bosserman, Linda

    2015-03-18

    Accurate assessment of HER2 status is critical in determining appropriate therapy for breast cancer patients but the best HER2 testing methodology has yet to be defined. In this study, we compared quantitative HER2 expression by the HERmark™ Breast Cancer Assay (HERmark) with routine HER2 testing by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH), and correlated HER2 results with overall survival (OS) of breast cancer patients in a multicenter Collaborative Biomarker Study (CBS). Two hundred and thirty-two formalin-fixed, paraffin-embedded breast cancer tissues and local laboratory HER2 testing results were provided by 11 CBS sites. HERmark assay and central laboratory HER2 IHC retesting were retrospectively performed in a blinded fashion. HER2 results by all testing methods were obtained in 192 cases. HERmark yielded a continuum of total HER2 expression (H2T) ranging from 0.3 to 403 RF/mm2 (approximately 3 logs). The distribution of H2T levels correlated significantly (P<0.0001) with all routine HER2 testing results. The concordance of positive and negative values (equivocal cases excluded) between HERmark and routine HER2 testing was 84% for local IHC, 96% for central IHC, 85% for local FISH, and 84% for local HER2 status. OS analysis revealed a significant correlation of shorter OS with HER2 positivity by local IHC (HR=2.6, P=0.016), central IHC (HR=3.2, P=0.015), and HERmark (HR=5.1, P<0.0001) in this cohort of patients most of whom received no HER2-targeted therapy. The OS curve of discordant low (HER2 positive but H2T low, 10% of all cases) was aligned with concordant negative (HER2 negative and H2T low, HR=1.9, P=0.444), but showed a significantly longer OS than concordant positive (HER2 positive and H2T high, HR=0.31, P=0.024). Conversely, the OS curve of discordant high (HER2 negative but H2T high, 9% of all cases) was aligned with concordant positive (HR=0.41, P=0.105), but showed a significantly shorter OS than concordant negative (HR=41, P<0.0001). Quantitative HER2 measurement by HERmark is highly sensitive, accurately quantifies HER2 protein expression and correlates well with routine HER2 testing. When HERmark and local HER2 results were discordant, HERmark more accurately predicted overall survival.

  19. Clinical validity of a population database definition of remission in patients with major depression.

    PubMed

    Sicras-Mainar, Antoni; Blanca-Tamayo, Milagrosa; Gutiérrez-Nicuesa, Laura; Salvatella-Pasant, Jordi; Navarro-Artieda, Ruth

    2010-02-11

    Major depression (MD) is one of the most frequent diagnoses in Primary Care. It is a disabling illness that increases the use of health resources. To describe the concordance between remission according to clinical assessment and remission obtained from the computerized prescription databases of patients with MD in a Spanish population. multicenter cross-sectional. The population under study was comprised of people from six primary care facilities, who had a MD episode between January 2003 and March 2007. A specialist in psychiatry assessed a random sample of patient histories and determined whether a certain patient was in remission according to clinical criteria (ICPC-2). Regarding the databases, patients were considered in remission when they did not need further prescriptions of AD for at least 6 months after completing treatment for a new episode. Validity indicators (sensitivity [S], specificity [Sp]) and clinical utility (positive and negative probability ratio [PPR] and [NPR]) were calculated. The concordance index was established using Cohen's kappa coefficient. Significance level was p < 0.05. 133 patient histories were reviewed. The kappa coefficient was 82.8% (confidence intervals [CI] were 95%: 73.1 - 92.6), PPR 9.8% and NPR 0.1%. Allocation discrepancies between both criteria were found in 11 patients. S was 92.5% (CI was 95%: 88.0 - 96.9%) and Sp was 90.6% (CI was 95%: 85.6 - 95.6%), p < 0.001. Reliability analysis: Cronbach's alpha: 90.6% (CI was 95%: 85.6 - 95.6%). Results show an acceptable level of concordance between remission obtained from the computerized databases and clinical criteria. The major discrepancies were found in diagnostic accuracy.

  20. Histotype-genotype correlation in 36 high-grade endometrial carcinomas.

    PubMed

    Hoang, Lien N; McConechy, Melissa K; Köbel, Martin; Han, Guangming; Rouzbahman, Marjan; Davidson, Ben; Irving, Julie; Ali, Rola H; Leung, Sam; McAlpine, Jessica N; Oliva, Esther; Nucci, Marisa R; Soslow, Robert A; Huntsman, David G; Gilks, C Blake; Lee, Cheng-Han

    2013-09-01

    Endometrioid, serous, and clear cell carcinomas are the major types of endometrial carcinoma. Histologic distinction between these different tumor types can be difficult in high-grade cases, in which significant interobserver diagnostic disagreement exists. Endometrioid and clear cell carcinomas frequently harbor ARID1A and/or PTEN mutations. Serous carcinoma acquires TP53 mutations/inactivation at onset, with a significant subset harboring an additional mutation in PPP2R1A. This study examines the correlation between tumor histotype and genotype in 36 previously genotyped high-grade endometrial carcinomas. This included 23 endometrioid/clear cell genotype and 13 serous genotype tumors. Eight subspecialty pathologists reviewed representative online slides and rendered diagnoses before and after receiving p53, p16, and estrogen receptor immunostaining results. κ statistics for histotype-genotype concordance were calculated. The average κ values for histotype-genotype concordance was 0.55 (range, 0.30 to 0.67) on the basis of morphologic evaluation alone and it improved to 0.68 (range, 0.54 to 0.81) after immunophenotype consideration (P<0.001). Genotype-incompatible diagnoses were rendered by at least 2 pathologists in 12 of 36 cases (33%) (3 cases by 2/8 pathologists, 2 by 3/8, 2 by 4/8, 3 by 6/8, 1 by 7/8, and 1 case by 8/8 pathologists). Six of the 12 were endometrioid/clear cell genotype tumors, and the other 6 were serous genotype tumors. The histopathologic features associated with histotype-genotype-discordant cases were reviewed, and specific diagnostic recommendations were made to improve concordance. This study found that although the majority of morphologic diagnoses are genotype concordant, genotype-incompatible diagnoses are made in a significant subset of cases. Judicious use and interpretation of p53 immunohistochemistry in selected scenarios can improve histotype-genotype concordance.

  1. Predicting chemically-induced skin reactions. Part II: QSAR models of skin permeability and the relationships between skin permeability and skin sensitization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alves, Vinicius M.; Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599; Muratov, Eugene

    Skin permeability is widely considered to be mechanistically implicated in chemically-induced skin sensitization. Although many chemicals have been identified as skin sensitizers, there have been very few reports analyzing the relationships between molecular structure and skin permeability of sensitizers and non-sensitizers. The goals of this study were to: (i) compile, curate, and integrate the largest publicly available dataset of chemicals studied for their skin permeability; (ii) develop and rigorously validate QSAR models to predict skin permeability; and (iii) explore the complex relationships between skin sensitization and skin permeability. Based on the largest publicly available dataset compiled in this study, wemore » found no overall correlation between skin permeability and skin sensitization. In addition, cross-species correlation coefficient between human and rodent permeability data was found to be as low as R{sup 2} = 0.44. Human skin permeability models based on the random forest method have been developed and validated using OECD-compliant QSAR modeling workflow. Their external accuracy was high (Q{sup 2}{sub ext} = 0.73 for 63% of external compounds inside the applicability domain). The extended analysis using both experimentally-measured and QSAR-imputed data still confirmed the absence of any overall concordance between skin permeability and skin sensitization. This observation suggests that chemical modifications that affect skin permeability should not be presumed a priori to modulate the sensitization potential of chemicals. The models reported herein as well as those developed in the companion paper on skin sensitization suggest that it may be possible to rationally design compounds with the desired high skin permeability but low sensitization potential. - Highlights: • It was compiled the largest publicly-available skin permeability dataset. • Predictive QSAR models were developed for skin permeability. • No concordance between skin sensitization and skin permeability has been found. • Structural rules for optimizing sensitization and penetration were established.« less

  2. Using automatically extracted information from mammography reports for decision-support

    PubMed Central

    Bozkurt, Selen; Gimenez, Francisco; Burnside, Elizabeth S.; Gulkesen, Kemal H.; Rubin, Daniel L.

    2016-01-01

    Objective To evaluate a system we developed that connects natural language processing (NLP) for information extraction from narrative text mammography reports with a Bayesian network for decision-support about breast cancer diagnosis. The ultimate goal of this system is to provide decision support as part of the workflow of producing the radiology report. Materials and methods We built a system that uses an NLP information extraction system (which extract BI-RADS descriptors and clinical information from mammography reports) to provide the necessary inputs to a Bayesian network (BN) decision support system (DSS) that estimates lesion malignancy from BI-RADS descriptors. We used this integrated system to predict diagnosis of breast cancer from radiology text reports and evaluated it with a reference standard of 300 mammography reports. We collected two different outputs from the DSS: (1) the probability of malignancy and (2) the BI-RADS final assessment category. Since NLP may produce imperfect inputs to the DSS, we compared the difference between using perfect (“reference standard”) structured inputs to the DSS (“RS-DSS”) vs NLP-derived inputs (“NLP-DSS”) on the output of the DSS using the concordance correlation coefficient. We measured the classification accuracy of the BI-RADS final assessment category when using NLP-DSS, compared with the ground truth category established by the radiologist. Results The NLP-DSS and RS-DSS had closely matched probabilities, with a mean paired difference of 0.004 ± 0.025. The concordance correlation of these paired measures was 0.95. The accuracy of the NLP-DSS to predict the correct BI-RADS final assessment category was 97.58%. Conclusion The accuracy of the information extracted from mammography reports using the NLP system was sufficient to provide accurate DSS results. We believe our system could ultimately reduce the variation in practice in mammography related to assessment of malignant lesions and improve management decisions. PMID:27388877

  3. Repeatability and sensitivity of high resolution blood volume mapping in mouse kidney disease.

    PubMed

    Wang, Feng; Jiang, Rosie T; Tantawy, Mohammed Noor; Borza, Dorin B; Takahashi, Keiko; Gore, John C; Harris, Raymond C; Takahashi, Takamune; Quarles, C Chad

    2014-04-01

    To evaluate the repeatability of MRI-derived relative blood volume (RBV) measurements in mouse kidneys across subjects and days and to evaluate sensitivity of this approach to renal pathology. A 7 Tesla MRI system and an intravascular iron-oxide contrast agent were used to acquire spin-echo-based renal RBV maps in 10 healthy mice on 2 consecutive days. Renal RBV maps were also acquired in the Alport and unilateral ureteral obstruction mouse models of renal disease. The average renal RBV measured on consecutive days was 19.97 ± 1.50 and 19.86 ± 1.62, yielding a concordance correlation coefficient of 0.94, indicating that this approach is highly repeatable. In the disease models, the RBV values were regionally dissimilar and substantially lower than those found in control mice. In vivo renal iron-oxide-based RBV mapping in mice complements the physiological information obtained from conventional assays of kidney function and could shed new insights into the pathological mechanisms of kidney disease. Copyright © 2013 Wiley Periodicals, Inc.

  4. Quantitative insights for the design of substrate-based SIRT1 inhibitors.

    PubMed

    Kokkonen, Piia; Mellini, Paolo; Nyrhilä, Olli; Rahnasto-Rilla, Minna; Suuronen, Tiina; Kiviranta, Päivi; Huhtiniemi, Tero; Poso, Antti; Jarho, Elina; Lahtela-Kakkonen, Maija

    2014-08-01

    Sirtuin 1 (SIRT1) is the most studied human sirtuin and it catalyzes the deacetylation reaction of acetylated lysine residues of its target proteins, for example histones. It is a promising drug target in the treatment of age-related diseases, such as neurodegenerative diseases and cancer. In this study, a series of known substrate-based sirtuin inhibitors was analyzed with comparative molecular field analysis (CoMFA), which is a three-dimensional quantitative structure-activity relationships (3D-QSAR) technique. The CoMFA model was validated both internally and externally, producing the statistical values concordance correlation coefficient (CCC) of 0.88, the mean value r(2)m of 0.66 and Q(2)F3 of 0.89. Based on the CoMFA interaction contours, 13 new potential inhibitors with high predicted activity were designed, and the activities were verified by in vitro measurements. This work proposes an effective approach for the design and activity prediction of new potential substrate-based SIRT1 inhibitors. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Development and Validation of a Weather-Based Model for Predicting Infection of Loquat Fruit by Fusicladium eriobotryae

    PubMed Central

    González-Domínguez, Elisa; Armengol, Josep; Rossi, Vittorio

    2014-01-01

    A mechanistic, dynamic model was developed to predict infection of loquat fruit by conidia of Fusicladium eriobotryae, the causal agent of loquat scab. The model simulates scab infection periods and their severity through the sub-processes of spore dispersal, infection, and latency (i.e., the state variables); change from one state to the following one depends on environmental conditions and on processes described by mathematical equations. Equations were developed using published data on F. eriobotryae mycelium growth, conidial germination, infection, and conidial dispersion pattern. The model was then validated by comparing model output with three independent data sets. The model accurately predicts the occurrence and severity of infection periods as well as the progress of loquat scab incidence on fruit (with concordance correlation coefficients >0.95). Model output agreed with expert assessment of the disease severity in seven loquat-growing seasons. Use of the model for scheduling fungicide applications in loquat orchards may help optimise scab management and reduce fungicide applications. PMID:25233340

  6. Concordance between macrophytes and macroinvertebrates in a Mediterranean river of central Apennine region.

    PubMed

    Traversetti, Lorenzo; Scalici, Massimiliano; Ginepri, Valeria; Manfrin, Alessandro; Ceschin, Simona

    2014-05-01

    The main aim of this study was to improve the knowledge about the concordance among macrophytes and macroinvertebrates to provide complementary information and facilitate the procedures for quality assessment of river ecosystems. Macrophytes and macroinvertebrates were collected in 11 sampling sites along a central Apennine calcareous river in October 2008 and June 2009. The concordance between the two biomonitoring groups was tested according to several environmental parameters. The comparison of data matrix similarities by Mantel test showed differences in the assemblage of macrophytes and macroinvertebrates along the river since correlation values were 0.04, p > 0.05 in October 2008 and 0.39, p > 0.05 in June 2009. The study revealed lack of concordance between the two groups, emphasizing that the information provided by macrophytes and macroinvertebrates does not overlap in terms of response to environmental parameters. Indeed, the two different biological groups resulted useful descriptors of different parameters. Together, they could represent a complementary tool to reflect the river environmental quality.

  7. Construction and utilization of a script concordance test as an assessment tool for DCEM3 (5th year) medical students in rheumatology.

    PubMed

    Mathieu, Sylvain; Couderc, Marion; Glace, Baptiste; Tournadre, Anne; Malochet-Guinamand, Sandrine; Pereira, Bruno; Dubost, Jean-Jacques; Soubrier, Martin

    2013-12-13

    The script concordance test (SCT) is a method for assessing clinical reasoning of medical students by placing them in a context of uncertainty such as they will encounter in their future daily practice. Script concordance testing is going to be included as part of the computer-based national ranking examination (iNRE).This study was designed to create a script concordance test in rheumatology and use it for DCEM3 (fifth year) medical students administered via the online platform of the Clermont-Ferrand medical school. Our SCT for rheumatology teaching was constructed by a panel of 19 experts in rheumatology (6 hospital-based and 13 community-based). One hundred seventy-nine DCEM3 (fifth year) medical students were invited to take the test. Scores were computed using the scoring key available on the University of Montreal website. Reliability of the test was estimated by the Cronbach alpha coefficient for internal consistency. The test comprised 60 questions. Among the 26 students who took the test (26/179: 14.5%), 15 completed it in its entirety. The reference panel of rheumatologists obtained a mean score of 76.6 and the 15 students had a mean score of 61.5 (p = 0.001). The Cronbach alpha value was 0.82. An online SCT can be used as an assessment tool for medical students in rheumatology. This study also highlights the active participation of community-based rheumatologists, who accounted for the majority of the 19 experts in the reference panel.A script concordance test in rheumatology for 5th year medical students.

  8. Consanguinity and spousal concordance in Kuwait.

    PubMed

    al-Kandari, Y; Crews, D E; Poirier, F E

    2002-12-01

    Consanguineous marriage is favored in Kuwait. This research focuses on the relationship of physical and cultural traits to marriage types in Kuwait and examines concordance as a function of consanguinity and marriage duration. In a nonrandom opportunistic sample of 242 couples anthropometric and blood pressure data have been collected as well as data on acculturation, religiosity, Farsi proficiency, level of education, occupation, and attitudes regarding fertility. Significant concordances occur in cultural characteristics among couples in all three types of marriages with respect to the degree of religiosity, acculturation, language similarity, education, and occupation. Non-consanguineous spouses have the highest concordance in educational level, occupation, and degree of acculturation, but the lowest for religiosity and Farsi proficiency. Nonkin marriages seem to be based on personal preferences. In the wider potential nonkin marriage pool spouses show more concordance in stature and education indicating the positive assortative mating for those traits. Non-consanguineous spouses show a significant association for triceps and subscapular skinfold thicknesses hip and waist circumferences, and body fat distribution. Unrelated spouses exhibit more concordance for physical traits than do related spouses. There is a significant correlation between spouses in first and double cousin marriages as well as in spouses in second and less than second cousin unions for systolic and diastolic blood pressure, while non-consanguineous spouses show a significant association in diastolic blood pressure only.

  9. A novel technique for bedside anorectal manometry in humans.

    PubMed

    Bharucha, A E; Stroetz, R; Feuerhak, K; Szarka, L A; Zinsmeister, A R

    2015-10-01

    Currently, anorectal manometry (ARM), which is used to diagnose defecatory disorders and identify anal weakness in fecal incontinence (FI) is generally conducted in specialized laboratories. Our aims were to compare anorectal functions measured with high-resolution manometry (HRM) and a novel portable manometry device. Anal pressures at rest, during squeeze, and simulated evacuation, and rectal sensation were evaluated with portable and HRM in 20 healthy women, 19 women with constipation, and 11 with FI. The relationship between anal pressures measured with portable and HRM was assessed by the concordance correlation coefficient (CCC), Bland Altman test, and paired t-tests. Anal pressures at rest (CCC 0.45; 95% CI: 0.29, 0.58) and during squeeze (CCC 0.60; 95% CI: 0.46, 0.72) measured with portable and HRM were correlated and inversely associated with the risk of FI. During simulated evacuation, the CCC for rectal pressure (0.62; 95% CI: 0.43, 0.76) was greater than that for anal pressure (CCC 0.22; 95% CI: 0.04, 0.39) and the rectoanal gradient (CCC 0.22; 95% CI: 0.02, 0.41). Rectal sensory thresholds for first sensation, the desire to defecate, and urgency measured by portable and HRM were also significantly correlated between techniques. For several parameters, differences between portable and HRM were statistically significant and the Bland Altman test was positive. Anorectal pressures and rectal sensation can be conveniently measured by portable manometry and are significantly correlated with high-resolution manometry. © 2015 John Wiley & Sons Ltd.

  10. Autofeedback from ultrasound images provides rapid improvement in palpation skills for identifying joint swelling in rheumatoid arthritis.

    PubMed

    Ogasawara, Michihiro; Murayama, Go; Yamada, Yusuke; Nemoto, Takuya; Kageyama, Michiaki; Toyama, Shoko; Kusaoi, Makio; Onuma, Shin; Kon, Takayuki; Sekiya, Fumio; Sugimoto, Kaoru; Matsudaira, Ran; Matsushita, Masakazu; Tada, Kurisu; Kempe, Kazuo; Yamaji, Ken; Tamura, Naoto; Takasaki, Yoshinari

    2012-06-01

    Joint swelling, an important factor in the classification criteria and disease activity assessment in rheumatoid arthritis (RA), renders joint palpation a necessary skill for physicians. Ultrasound (US) examination that visualizes soft tissue abnormalities is now used to assess musculoskeletal disease. We assessed the usefulness of US assessments in enhancing physical joint examination skills. We examined 1944 joints (bilateral shoulder, elbow, wrist, metacarpophalangeal joints 1-5, and knee joints) in 108 patients with RA during April-July 2011. We first physically examined and confirmed joint swelling; subsequently, the same rheumatologist conducted US examinations and multiple assessors graded the joint swelling. When the 2 results differed, we received autofeedback from the US results to improve the physical examination skills. The sensitivities and specificities of physical examination for US-detected swollen joint, the correlation coefficient (CC) of the swollen joint counts, and the concordance rate in each patient for joint swelling sites and power Doppler (PD)-positive sites with the κ coefficients between the physical and US examinations were compared over time. We found that the sensitivity of physical examination increased by 42 percentage points (pp), while the specificity decreased by 18 pp. The average CC in June-July was greater than that in April-May. The percentage of κ coefficients > 0.8 increased from 8.8% to 17% for joint swelling and from 8.3% to 14% for PD-positive sites. Our results suggest that autofeedback from US assessment provides quick improvement in palpation skills for identifying joint swelling in patients with RA.

  11. Binary similarity measures for fingerprint analysis of qualitative metabolomic profiles.

    PubMed

    Rácz, Anita; Andrić, Filip; Bajusz, Dávid; Héberger, Károly

    2018-01-01

    Contemporary metabolomic fingerprinting is based on multiple spectrometric and chromatographic signals, used either alone or combined with structural and chemical information of metabolic markers at the qualitative and semiquantitative level. However, signal shifting, convolution, and matrix effects may compromise metabolomic patterns. Recent increase in the use of qualitative metabolomic data, described by the presence (1) or absence (0) of particular metabolites, demonstrates great potential in the field of metabolomic profiling and fingerprint analysis. The aim of this study is a comprehensive evaluation of binary similarity measures for the elucidation of patterns among samples of different botanical origin and various metabolomic profiles. Nine qualitative metabolomic data sets covering a wide range of natural products and metabolomic profiles were applied to assess 44 binary similarity measures for the fingerprinting of plant extracts and natural products. The measures were analyzed by the novel sum of ranking differences method (SRD), searching for the most promising candidates. Baroni-Urbani-Buser (BUB) and Hawkins-Dotson (HD) similarity coefficients were selected as the best measures by SRD and analysis of variance (ANOVA), while Dice (Di1), Yule, Russel-Rao, and Consonni-Todeschini 3 ranked the worst. ANOVA revealed that concordantly and intermediately symmetric similarity coefficients are better candidates for metabolomic fingerprinting than the asymmetric and correlation based ones. The fingerprint analysis based on the BUB and HD coefficients and qualitative metabolomic data performed equally well as the quantitative metabolomic profile analysis. Fingerprint analysis based on the qualitative metabolomic profiles and binary similarity measures proved to be a reliable way in finding the same/similar patterns in metabolomic data as that extracted from quantitative data.

  12. Estimating individual glomerular volume in the human kidney: clinical perspectives

    PubMed Central

    Puelles, Victor G.; Zimanyi, Monika A.; Samuel, Terence; Hughson, Michael D.; Douglas-Denton, Rebecca N.; Bertram, John F.

    2012-01-01

    Background. Measurement of individual glomerular volumes (IGV) has allowed the identification of drivers of glomerular hypertrophy in subjects without overt renal pathology. This study aims to highlight the relevance of IGV measurements with possible clinical implications and determine how many profiles must be measured in order to achieve stable size distribution estimates. Methods. We re-analysed 2250 IGV estimates obtained using the disector/Cavalieri method in 41 African and 34 Caucasian Americans. Pooled IGV analysis of mean and variance was conducted. Monte-Carlo (Jackknife) simulations determined the effect of the number of sampled glomeruli on mean IGV. Lin’s concordance coefficient (RC), coefficient of variation (CV) and coefficient of error (CE) measured reliability. Results. IGV mean and variance increased with overweight and hypertensive status. Superficial glomeruli were significantly smaller than juxtamedullary glomeruli in all subjects (P < 0.01), by race (P < 0.05) and in obese individuals (P < 0.01). Subjects with multiple chronic kidney disease (CKD) comorbidities showed significant increases in IGV mean and variability. Overall, mean IGV was particularly reliable with nine or more sampled glomeruli (RC > 0.95, <5% difference in CV and CE). These observations were not affected by a reduced sample size and did not disrupt the inverse linear correlation between mean IGV and estimated total glomerular number. Conclusions. Multiple comorbidities for CKD are associated with increased IGV mean and variance within subjects, including overweight, obesity and hypertension. Zonal selection and the number of sampled glomeruli do not represent drawbacks for future longitudinal biopsy-based studies of glomerular size and distribution. PMID:21984554

  13. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  14. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  15. Subthalamic Nucleus Visualization on Routine Clinical Preoperative MRI Scans: A Retrospective Study of Clinical and Image Characteristics Predicting Its Visualization.

    PubMed

    Ranjan, Manish; Boutet, Alexandre; Xu, David S; Lozano, Christopher S; Kumar, Rajeev; Fasano, Alfonso; Kucharczyk, Walter; Lozano, Andres M

    2018-05-30

    The visualization of the subthalamic nucleus (STN) on magnetic resonance imaging (MRI) is variable. Studies of the contribution of patient-related factors and intrinsic brain volumetrics to STN visualization have not been reported previously. To assess the visualization of the STN during deep brain stimulation (DBS) surgery in a clinical setting. Eighty-two patients undergoing pre-operative MRI to plan for STN DBS for Parkinson disease were retrospectively studied. The visualization of the STN and its borders was assessed and scored by 3 independent observers using a 4-point ordinal scale (from 0 = not seen to 3 = excellent visualization). This measure was then correlated with the patients' clinical information and brain volumes. The mean STN visualization scores were 1.68 and 1.63 for the right and left STN, respectively, with a good interobserver reliability (intraclass correlation coefficient: 0.744). Older age and decreased white matter volume were negatively correlated with STN visualization (p < 0.05). STN visualization is only fair to good on routine MRI with good concordance of interindividual rating. Advancing age and decreased white matter are associated with poor visualization of the STN. Knowledge about factors contributing to poor visualization of the STN could alert a surgeon to modify the imaging strategy to optimize surgical targeting. © 2018 S. Karger AG, Basel.

  16. Genotype imputation in the domestic dog

    PubMed Central

    Meurs, K. M.

    2016-01-01

    Application of imputation methods to accurately predict a dense array of SNP genotypes in the dog could provide an important supplement to current analyses of array-based genotyping data. Here, we developed a reference panel of 4,885,283 SNPs in 83 dogs across 15 breeds using whole genome sequencing. We used this panel to predict the genotypes of 268 dogs across three breeds with 84,193 SNP array-derived genotypes as inputs. We then (1) performed breed clustering of the actual and imputed data; (2) evaluated several reference panel breed combinations to determine an optimal reference panel composition; and (3) compared the accuracy of two commonly used software algorithms (Beagle and IMPUTE2). Breed clustering was well preserved in the imputation process across eigenvalues representing 75 % of the variation in the imputed data. Using Beagle with a target panel from a single breed, genotype concordance was highest using a multi-breed reference panel (92.4 %) compared to a breed-specific reference panel (87.0 %) or a reference panel containing no breeds overlapping with the target panel (74.9 %). This finding was confirmed using target panels derived from two other breeds. Additionally, using the multi-breed reference panel, genotype concordance was slightly higher with IMPUTE2 (94.1 %) compared to Beagle; Pearson correlation coefficients were slightly higher for both software packages (0.946 for Beagle, 0.961 for IMPUTE2). Our findings demonstrate that genotype imputation from SNP array-derived data to whole genome-level genotypes is both feasible and accurate in the dog with appropriate breed overlap between the target and reference panels. PMID:27129452

  17. Calculating regional tissue volume for hyperthermic isolated limb perfusion: Four methods compared.

    PubMed

    Cecchin, D; Negri, A; Frigo, A C; Bui, F; Zucchetta, P; Bodanza, V; Gregianin, M; Campana, L G; Rossi, C R; Rastrelli, M

    2016-12-01

    Hyperthermic isolated limb perfusion (HILP) can be performed as an alternative to amputation for soft tissue sarcomas and melanomas of the extremities. Melphalan and tumor necrosis factor-alpha are used at a dosage that depends on the volume of the limb. Regional tissue volume is traditionally measured for the purposes of HILP using water displacement volumetry (WDV). Although this technique is considered the gold standard, it is time-consuming and complicated to implement, especially in obese and elderly patients. The aim of the present study was to compare the different methods described in the literature for calculating regional tissue volume in the HILP setting, and to validate an open source software. We reviewed the charts of 22 patients (11 males and 11 females) who had non-disseminated melanoma with in-transit metastases or sarcoma of the lower limb. We calculated the volume of the limb using four different methods: WDV, tape measurements and segmentation of computed tomography images using Osirix and Oncentra Masterplan softwares. The overall comparison provided a concordance correlation coefficient (CCC) of 0.92 for the calculations of whole limb volume. In particular, when Osirix was compared with Oncentra (validated for volume measures and used in radiotherapy), the concordance was near-perfect for the calculation of the whole limb volume (CCC = 0.99). With methods based on CT the user can choose a reliable plane for segmentation purposes. CT-based methods also provides the opportunity to separate the whole limb volume into defined tissue volumes (cortical bone, fat and water). Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas.

    PubMed

    Tennent-Brown, Brett S; Koenig, Amie; Williamson, Lisa H; Boston, Raymond C

    2011-08-01

    To compare the performance of 3 point-of-care glucose meters in adult and juvenile alpacas with that of a laboratory-based analyzer. Evaluation study. 35 adult alpacas and 21 juvenile alpacas. Whole blood samples obtained via jugular venipuncture were tested with all 3 point-of-care glucose meters; plasma samples were also tested with 1 of those meters. Glucose concentrations determined by use of the point-of-care meters were compared with results from the laboratory-based analyzer. Plasma glucose concentrations determined by use of the laboratory-based analyzer ranged from 36 to 693 mg/dL. Over the entire range of glucose concentrations tested, the Lin concordance correlation coefficient (agreement) was significant and excellent for all comparisons. Concordance decreased for 1 glucometer when testing whole blood samples over a narrower range of glucose concentrations (50 to 200 mg/dL). Bias was typically small (< 10 mg/dL) for 3 of the 4 comparisons but considerable for 1 meter with the use of whole blood. The limits of agreement were wide for all comparisons over the entire range of glucose concentrations tested but decreased to within acceptable limits when the narrower glucose range (50 to 200 mg/dL) was analyzed for 3 of the comparisons. For samples with a PCV < 25%, bias and the limits of agreement were greater for one of the meters tested. Discrepancies between point-of-care glucose meters and reference techniques can be considerable in alpacas, emphasizing the importance of assessing individual meter performance in a target population.

  19. Validation of Nutritional Risk Screening-2002 in a Hospitalized Adult Population.

    PubMed

    Bolayir, Başak; Arik, Güneş; Yeşil, Yusuf; Kuyumcu, Mehmet Emin; Varan, Hacer Doğan; Kara, Özgür; Güngör, Anil Evrim; Yavuz, Burcu Balam; Cankurtaran, Mustafa; Halil, Meltem Gülhan

    2018-03-30

    Malnutrition in hospitalized patients is a serious problem and is associated with a number of adverse outcomes. The Nutritional Risk Screening-2002 (NRS-2002) tool was designed to identify patients at nutrition risk. The validation of NRS-2002 compared with detailed clinical assessment of nutrition status was not studied before in hospitalized Turkish adults. The aim of this study is to determine validity, sensitivity, and specificity of the Turkish version of NRS-2002 in a hospitalized adult population. A total of 271 consecutive hospitalized patients aged >18 years admitted to surgical and medical wards of a university hospital in Turkey were included in this single-center non interventional validity study. Assessment by geriatricians was used as the reference method. Two geriatricians experienced in the field of malnutrition interpreted the patients' nutrition status after the evaluation of several parameters. Patients were divided into "at nutrition risk" and "not at nutrition risk" groups by geriatricians. Concordance between the 2 geriatricians' clinical assessments was analyzed by κ statistics. Excellent concordance was found; therefore, the first geriatrician's decisions were accepted as the gold standard. The correlation of nutrition status of the patients, determined with NRS-2002 and experienced geriatrician's decisions, was evaluated for the validity. NRS-2002 has a sensitivity of 88% and specificity of 92% when compared with professional assessment. The positive and negative predictive values were 87% and 92%, respectively. Testretest agreement was excellent as represented by a κ coefficient of 0.956. NRS-2002 is a valid tool to assess malnutrition risk in Turkish hospitalized patients. © 2018 American Society for Parenteral and Enteral Nutrition.

  20. Measurement of Dynamic Urethral Pressures with a High Resolution Manometry System in Continent and Incontinent Women

    PubMed Central

    Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W.

    2015-01-01

    Objectives Female stress urinary incontinence (SUI) is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under dynamic conditions. An 8-French high resolution manometry catheter (HRM) currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25ms response rate and circumferential pressure sensors along the length of the catheter (ManoScan® ESO, Given Imaging). We evaluated the concordance, repeatability, and tolerability of this catheter. Methods We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. Results The correlation coefficient for resting MUCPs measured by HRM vs. UPP was high (r = 0.79, p<0.001). Repeatability after catheter repositioning was high for rest, cough, and strain with HRM: r= 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, strain) were higher in continent than incontinent subjects (all p < 0.001) and decreased more in incontinent subjects than continent subjects during cough and strain maneuvers compared to rest. Conclusions This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women. PMID:25185595

  1. Measurement of dynamic urethral pressures with a high-resolution manometry system in continent and incontinent women.

    PubMed

    Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W

    2015-01-01

    Female stress urinary incontinence is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under these conditions. An 8-French high-resolution manometry (HRM) catheter currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25-millisecond response rate and circumferential pressure sensors along the length of the catheter (ManoScan ESO; Given Imaging, Yoqneam, Israel). We evaluated the concordance, repeatability, and tolerability of this catheter. We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water-perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress-incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. The correlation coefficient for resting MUCPs measured by HRM versus UPP was high (r = 0.79, P < 0.001). Repeatability after catheter repositioning was high for rest, cough, and strain with HRM: r = 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, and strain) were higher in continent than in incontinent subjects (all P < 0.001) and decreased more in incontinent subjects than in continent subjects during cough and strain maneuvers compared to rest. This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women.

  2. Analytical variability of estimated platelet counts on canine blood smears.

    PubMed

    Paltrinieri, Saverio; Paciletti, Veronica; Zambarbieri, Jari

    2018-06-04

    The analytical variability of estimated platelet counts in dogs has not been reported. The purpose of this study was to assess the magnitude of analytical imprecision of platelet estimates and the possible impact of this imprecision on clinical decisions. Three independent observers counted the number of platelets in 3 different areas (LE = lateral edge; CM = central monolayer; FE = feathered edge) of 30 canine blood smears with different instrumental platelet counts. The coefficient of variation (CV) for each observer was calculated in different areas of each smear (intra-observer variability), among different regions of each smear (inter-area variability), and among different observers in each area (inter-observer variability). The influence of these variabilities on the classification of platelet estimates as adequate, increased, or decreased was also assessed. The CVs recorded in the different areas by each observer ranged from 8% to 88% and were negatively correlated (P < .001, r = -.65) with the mean number of platelets per field. The mean platelet number was significantly lower in the FE and significantly higher in the CM compared with the LE, but the magnitude of this difference varied with the operators. The concordance among operators regarding platelet estimates was fair (k = 0.36) to substantial (k = 0.71) depending on the area. The overall inter-area concordance was moderate (k = 0.59). Platelet estimates suffer from high variability that could lead to patient misclassification. Therefore, guidelines to standardize the platelet estimate are needed. © 2018 American Society for Veterinary Clinical Pathology.

  3. Modelling spatial concordance between Rocky Mountain spotted fever disease incidence and habitat probability of its vector Dermacentor variabilis (American dog tick).

    PubMed

    Atkinson, Samuel F; Sarkar, Sahotra; Aviña, Aldo; Schuermann, Jim A; Williamson, Phillip

    2012-11-01

    The spatial distribution of Dermacentor variabilis, the most commonly identified vector of the bacterium Rickettsia rickettsii which causes Rocky Mountain spotted fever (RMSF) in humans, and the spatial distribution of RMSF, have not been previously studied in the south central United States of America, particularly in Texas. From an epidemiological perspective, one would tend to hypothesise that there would be a high degree of spatial concordance between the habitat suitability for the tick and the incidence of the disease. Both maximum-entropy modelling of the tick's habitat suitability and spatially adaptive filters modelling of the human incidence of RMSF disease provide reliable portrayals of the spatial distributions of these phenomenons. Even though rates of human cases of RMSF in Texas and rates of Dermacentor ticks infected with Rickettsia bacteria are both relatively low in Texas, the best data currently available allows a preliminary indication that the assumption of high levels of spatial concordance would not be correct in Texas (Kappa coefficient of agreement = 0.17). It will take substantially more data to provide conclusive findings, and to understand the results reported here, but this study provides an approach to begin understanding the discrepancy.

  4. Concordance between Self and Standardized Patient Ratings of Medical Students' Communication Skills.

    PubMed

    Je, Min Ji; Lee, Su Hyun; Lee, Chang Hyung; Kim, Sung Soo

    2013-03-01

    The purpose of this study was to examine the concordance between self and standardized patient (SP) ratings of medical students' communication skills. Forty-three students interviewed SPs. The students were asked to complete a communication skills questionnaire that comprised 2 measures (empathy and interpersonal communication) before the interview. After each student's interview with the SP, the latter completed the same questionnaire as the students. Based on Lin's concordance coefficient, there was strong disconcordance between students' self-ratings and the SPs' ratings. With regard to empathic communication, more than 50% of students who considered themselves higher than middle level were regarded by SP as low level. On interpersonal communication, 39% of students who assessed themselves as higher than middle level were scored low level by SPs. There was strong disconcordance between students' self-ratings and the SPs' ratings-students tended to overevaluate themselves regarding their communication skills. These differences might result in patient dissatisfaction and noncompliance. Further, it could become a serious hindrance to the development of a good doctor-patient relationship. Medical educators should make sincere efforts to reduce this gap by teaching medical students the importance of the patients' perception of his doctors' communication skills.

  5. Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

    PubMed Central

    Van Keer, Jan; Barbosa Breda, João; Nassiri, Vahid; De Deyne, Cathy; Genbrugge, Cornelia; Abegão Pinto, Luís; Stalmans, Ingeborg; Vandewalle, Evelien

    2018-01-01

    Background To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO2-retinal) and venous (SvO2-retinal) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lin’s concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial:venous ratio as 0.3 x SaO2-retinal + 0.7 x SvO2-retinal. The individual relative weight of SaO2-retinal and SvO2-retinal to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 ± 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO2-retinal and SvO2-retinal (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO2-retinal and SvO2-retinal to obtain SO2-transcranial were 0.31 ± 0.11 and 0.69 ± 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial:venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation. PMID:29304150

  6. Psychiatric patients' preferences and experiences in clinical decision-making: examining concordance and correlates of patients' preferences.

    PubMed

    De las Cuevas, Carlos; Peñate, Wenceslao; de Rivera, Luis

    2014-08-01

    To assess the concordance between patients' preferred role in clinical decision-making and the role they usually experience in their psychiatric consultations and to analyze the influence of socio-demographic, clinical and personality characteristics on patients' preferences. 677 consecutive psychiatric outpatients were invited to participate in a cross-sectional survey and 507 accepted. Patients completed Control Preference Scale twice consecutively before consultation, one for their preferences of participation and another for the style they usually experienced until then, and locus of control and self-efficacy scales. Sixty-three percent of psychiatric outpatients preferred a collaborative role in decision-making, 35% preferred a passive role and only a 2% an active one. A low concordance for preferred and experienced participation in medical decision-making was registered, with more than a half of patients wanting a more active role than they actually had. Age and doctors' health locus of control orientation were found to be the best correlates for participation preferences, while age and gender were for experienced. Psychiatric diagnoses registered significant differences in patients' preferences of participation but no concerning experiences. The limited concordance between preferred and experienced roles in psychiatric patients is indicative that clinicians need to raise their sensitivity regarding patient's participation. The assessment of patient's attribution style should be useful for psychiatrist to set objectives and priority in the communication with their patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Concordances and discrepancies between ICD-10 and DSM-IV criteria for anxiety disorders in childhood and adolescence

    PubMed Central

    2012-01-01

    Background Mental disorders are classified by two major nosological systems, the ICD-10 and the DSM-IV-TR, consisting of different diagnostic criteria. The present study investigated the diagnostic concordance between the two systems for anxiety disorders in childhood and adolescence, in particular for separation anxiety disorder (SAD), specific phobia, social phobia, and generalized anxiety disorder (GAD). Methods A structured clinical interview, the Kinder-DIPS, was administered to 210 children and 258 parents. The percentage of agreement, kappa, and Yule’s Y coefficients were calculated for all diagnoses. Specific criteria causing discrepancies between the two classification systems were identified. Results DSM-IV-TR consistently classified more children than ICD-10 with an anxiety disorder, with a higher concordance between DSM-IV-TR and the ICD-10 child section (F9) than with the adult section (F4) of the ICD-10. This result was found for all four investigated anxiety disorders. The results revealed low to high levels of concordance and poor to good agreement between the classification systems, depending on the anxiety disorder. Conclusions The two classification systems identify different children with an anxiety disorder. However, it remains an open question, whether the research results can be generalized to clinical practice since DSM-IV-TR is mainly used in research while ICD-10 is widely established in clinical practice in Europe. Therefore, the population investigated by the DSM (research population) is not identical with the population examined using the ICD (clinical population). PMID:23267678

  8. Correlates of non-concordance between perceived and objective measures of walkability.

    PubMed

    Gebel, Klaus; Bauman, Adrian; Owen, Neville

    2009-04-01

    Objective and self-reported physical environmental attributes have been related to physical activity. We examined the characteristics of adults who are resident in objectively identified high walkable neighborhoods but whose perceptions of neighborhood attributes are not concordant with objective attributes relating to high walkability. Neighborhood built-environment attributes relating to walkability (dwelling density, intersection density, land use mix, and net retail area) were determined objectively, using Geographic Information System databases; data on corresponding perceptions of local environment attributes (from the Neighborhood Environment Walkability Scale) were derived from a self-completion survey of a socially diverse sample of 2,650 adults aged 19 to 65. Objective and perceived walkability attributes were categorized using median splits, and correlates of non-concordance were determined using multiple logistic regression models. There was a fair overall agreement between objectively determined walkability and perceived walkability (Kappa = 0.35, 95% CI = 0.31-0.39). Among those resident in objectively assessed high walkable areas (n = 1,063), 32.1% perceived them to be low walkable; conversely, 32.7% (n = 1,021) resident in objectively determined low walkability areas perceived them to be high. For residents of objectively determined high walkable areas, the characteristics that differentiated those with perceptions of low walkability (non-concordant perceptions) from those with concordant perceptions of high walkability were: not being university-educated (OR = 1.47, 95% CI = 1.06-2.04); having lower household incomes (OR = 1.54, 95% CI = 1.09-2.17); being overweight (OR = 1.46, 95% CI = 1.03-2.07); and walking fewer days per week for transport (OR = 1.75, 95% CI = 1.11-2.70). Higher walking times and more positive cognitive variables were noted among participants who lived in a neighborhood with low walkability that was perceived as high compared to those who lived in a high walkable environment that was perceived as low walkable. Adults with lower educational attainment and lower incomes, who were overweight, or who were less physically active for transportation purposes, were more likely to misperceive their high walkable neighborhood as low walkable. There is the potential for physical activity promotion and persuasion strategies to address non-concordant perceptions, especially among those who live in high walkable environments but perceive them to be low and also among those who are socially disadvantaged and are less active. Perceptions of environmental attributes may be more strongly correlated with cognitive antecedents and with behavior than are objective measures.

  9. Clinical gait evaluation of patients with knee osteoarthritis.

    PubMed

    Sun, Jun; Liu, Yancheng; Yan, Songhua; Cao, Guanglei; Wang, Shasha; Lester, D Kevin; Zhang, Kuan

    2017-10-01

    Knee osteoarthritis (KOA) is the most common osteoarthritis in lower limbs, and gait measurement is important to evaluate walking function of KOA patients before and after treatment. The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3) is a portable gait analysis system to evaluate gaits. This study is to evaluate the accuracy and reliability of IDEEA3 for gait measurement of KOA patients. Meanwhile, gait differences between KOA patients and healthy subjects are examined. Twelve healthy volunteers were recruited for measurement comparison of gait cycle (GC), cadence, step length, velocity and step counts between a motion analysis system and a high-speed camera (GoPro Hero3). Twenty-three KOA patients were recruited for measurement comparison of former five parameters between GoPro Hero3 and IDEEA3. Paired t-test, Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC) were used for data analysis. All p-values of paired t-tests for GC, cadence, step length and velocity were greater than 0.05 while all CCC and ICC results were above 0.95. The measurements of GC, cadence, step length, velocity and step counts by motion analysis system are highly consistent with the measurements by GoPro Hero3. The measurements of former parameters by GoPro Hero3 are not statistically different from the measurements by IDEEA3. IDEEA3 can be effectively used for the measurement of GC, cadence, step length, velocity and step counts in KOA patients. The KOA patients walk with longer GC, lower cadence, shorter step length and slower speed compared with healthy subjects in natural speed with flat shoes. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Locoregional Control of Non-Small Cell Lung Cancer in Relation to Automated Early Assessment of Tumor Regression on Cone Beam Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brink, Carsten, E-mail: carsten.brink@rsyd.dk; Laboratory of Radiation Physics, Odense University Hospital; Bernchou, Uffe

    2014-07-15

    Purpose: Large interindividual variations in volume regression of non-small cell lung cancer (NSCLC) are observable on standard cone beam computed tomography (CBCT) during fractionated radiation therapy. Here, a method for automated assessment of tumor volume regression is presented and its potential use in response adapted personalized radiation therapy is evaluated empirically. Methods and Materials: Automated deformable registration with calculation of the Jacobian determinant was applied to serial CBCT scans in a series of 99 patients with NSCLC. Tumor volume at the end of treatment was estimated on the basis of the first one third and two thirds of the scans.more » The concordance between estimated and actual relative volume at the end of radiation therapy was quantified by Pearson's correlation coefficient. On the basis of the estimated relative volume, the patients were stratified into 2 groups having volume regressions below or above the population median value. Kaplan-Meier plots of locoregional disease-free rate and overall survival in the 2 groups were used to evaluate the predictive value of tumor regression during treatment. Cox proportional hazards model was used to adjust for other clinical characteristics. Results: Automatic measurement of the tumor regression from standard CBCT images was feasible. Pearson's correlation coefficient between manual and automatic measurement was 0.86 in a sample of 9 patients. Most patients experienced tumor volume regression, and this could be quantified early into the treatment course. Interestingly, patients with pronounced volume regression had worse locoregional tumor control and overall survival. This was significant on patient with non-adenocarcinoma histology. Conclusions: Evaluation of routinely acquired CBCT images during radiation therapy provides biological information on the specific tumor. This could potentially form the basis for personalized response adaptive therapy.« less

  11. Assessing the growth of preterm infants using detailed anthropometry.

    PubMed

    Ashton, James J; Johnson, Mark J; Pond, Jenny; Crowley, Philippa; Dimitrov, Borislav D; Pearson, Freya; Beattie, R Mark

    2017-06-01

    Preterm infants display altered body composition compared to term infants, and weight gain is a crude indicator body composition. Childhood mid-upper arm circumference (MUAC) is a measure of nutritional status. This study investigates MUAC and mid-thigh circumference (MTC) to monitor growth in preterm infants. Preterm infants (<30-week gestation) were recruited. MUAC, MTC, weight, length and head circumference (HC) were measured at recruitment and weekly intervals until discharge. Descriptive, correlation and regression analyses were used. Ninety-three infants were recruited. Median measurement duration was eight weeks (1-19). Median gestational age was 27 weeks (23-29). Analysis by curve estimation displayed a mean increase of 2.58 mm/week (left MUAC) (p ≤ 0.0001), 2.56 mm/week (right MUAC) (p ≤ 0.0001), 4.16 mm/week (left MTC) (p ≤ 0.0001), 4.20 mm/week (right MTC) (p ≤ 0.0001). Coefficients of determination (R 2 ) were calculated using a growth regression model for MUAC and MTC (0.866-0.917); measures were comparable to growth modelling of weight (0.913), length (0.945) and HC (0.928). High concordance between left and right MUAC and MTC generated a Pearson's correlation coefficient of 0.999 (MUAC) (p ≤ 0.001) and 0.994 (MTC) (p ≤ 0.001). Data demonstrate the potential utility of MUAC and MTC as additional measures of growth in preterm infants that are reproducible over time. There is potential to gain insights to improve lean-mass accretion in preterm infants. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  12. Short communication: Prediction of retention pay-off using a machine learning algorithm.

    PubMed

    Shahinfar, Saleh; Kalantari, Afshin S; Cabrera, Victor; Weigel, Kent

    2014-05-01

    Replacement decisions have a major effect on dairy farm profitability. Dynamic programming (DP) has been widely studied to find the optimal replacement policies in dairy cattle. However, DP models are computationally intensive and might not be practical for daily decision making. Hence, the ability of applying machine learning on a prerun DP model to provide fast and accurate predictions of nonlinear and intercorrelated variables makes it an ideal methodology. Milk class (1 to 5), lactation number (1 to 9), month in milk (1 to 20), and month of pregnancy (0 to 9) were used to describe all cows in a herd in a DP model. Twenty-seven scenarios based on all combinations of 3 levels (base, 20% above, and 20% below) of milk production, milk price, and replacement cost were solved with the DP model, resulting in a data set of 122,716 records, each with a calculated retention pay-off (RPO). Then, a machine learning model tree algorithm was used to mimic the evaluated RPO with DP. The correlation coefficient factor was used to observe the concordance of RPO evaluated by DP and RPO predicted by the model tree. The obtained correlation coefficient was 0.991, with a corresponding value of 0.11 for relative absolute error. At least 100 instances were required per model constraint, resulting in 204 total equations (models). When these models were used for binary classification of positive and negative RPO, error rates were 1% false negatives and 9% false positives. Applying this trained model from simulated data for prediction of RPO for 102 actual replacement records from the University of Wisconsin-Madison dairy herd resulted in a 0.994 correlation with 0.10 relative absolute error rate. Overall results showed that model tree has a potential to be used in conjunction with DP to assist farmers in their replacement decisions. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Measurement of steroids in rats after exposure to an endocrine disruptor: mass spectrometry and radioimmunoassay demonstrate similar results.

    PubMed

    Riffle, Brandy W; Henderson, W Matthew; Laws, Susan C

    2013-01-01

    Commercially available radioimmunoassays (RIAs) are frequently used to evaluate the effects of endocrine disrupting chemicals (EDCs) on steroidogenesis in rats. Currently there are limited data comparing steroid concentrations in rats as measured by RIAs to those obtained using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). This study evaluates the concordance of serum and urine steroid concentrations as quantified by select RIA kits and LC-MS/MS following exposure to an EDC, atrazine (ATR). Adult male rats were orally dosed with ATR (200 mg/kg/day) or methylcellulose (1%, vehicle control) for 5 days. Serum was collected and separated into aliquots for analysis. Serum was assayed by RIA for androstenedione (ANDRO), corticosterone (CORT), estradiol (E2), estrone (E1), progesterone (P4), and testosterone (T). Serum was extracted prior to LC-MS/MS analysis with positive electrospray ionization in multiple-reaction monitoring mode for ANDRO, CORT, P4, and T. E1 and E2 concentrations were quantified similarly by LC-MS/MS, following derivatization with dansyl chloride. To compare CORT values from urine, pregnant adult rats were orally dosed with either ATR (100 mg/kg/day) or methylcellulose for 5 days (i.e., gestational days 14-18). Urine samples were collected daily and assayed for CORT by RIA and LC-MS/MS as described above. Data analyses demonstrated significant agreement between the two detection methods as assessed by Pearson product-moment correlation coefficient, Bland-Altman analysis, and the interclass correlation coefficient. No statistically significant differences were observed between RIA and LC-MS/MS means for any of the steroids assayed. These findings indicate a significant correlation between the measurement of steroids within rat serum and urine using RIA kits and LC-MS/MS. Differences in the absolute measurements existed, but these were not statistically significant. These findings indicate that steroids may be reliably measured in rat biological media using RIAs or LC-MS/MS. © 2013.

  14. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    PubMed Central

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. PMID:26509265

  15. Performance evaluation of the microINR® point-of-care INR-testing system.

    PubMed

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  16. PILATES (Physical Activity and Diet Survey): An Italian Self-Administered Questionnaire Evaluating Diet Habits of Gym-Goers. Validation Process.

    PubMed

    Gianfredi, Vincenza; Nucci, Daniele; Ceccarelli, Francesco; Villarini, Milena; Moretti, Massimo

    2018-04-19

    PILATES study aims are to assess the main characteristics related to food habits, diet behaviors, and nutrition knowledge and how and where gym-goers get information on dietary supplementation. We present evidence for the reliability, feasibility, and construct validity of the PILATES questionnaire. Cohen's kappa statistic (k) for dichotomous variables was used to assess the agreement between the two administrations (interrater agreement). The nutrient composition and energy of food were derived from the Food Composition Database for Epidemiological Studies in Italy (Banca Dati di Composizione degli Alimenti per Studi Epidemiologici in Italia - BDA). Because of energy intake, waist circumference and weight are continuous variables; we calculate the agreement between the two interviews using Spearman's rho coefficient (nonparametric measure of rank correlation). An Italian 21-item self-administered questionnaire was designed and pretested on 28 students in food science and human nutrition at the University of Perugia who were enrolled on a voluntary basis. After verifying the feasibility of the questionnaire, pretest evaluation showed a generally high concordance with an 87.32% of agreement and k value = 0.71 ± 0.23. In addition, weight, daily energy intake, and waist circumference confirmed a statistically significant agreement (p <.001, Spearman rho coefficient). PILATES questionnaire is a valid tool to estimate dietary intakes in a fairly simple, cost-effective, and timesaving manner.

  17. Variation in neurophysiological function and evidence of quantitative electroencephalogram discordance: predicting cocaine-dependent treatment attrition.

    PubMed

    Venneman, Sandy; Leuchter, Andrew; Bartzokis, George; Beckson, Mace; Simon, Sara L; Schaefer, Melodie; Rawson, Richard; Newton, Tom; Cook, Ian A; Uijtdehaage, Sebastian; Ling, Walter

    2006-01-01

    Cocaine treatment trials suffer from a high rate of attrition. We examined pretreatment neurophysiological factors to identify participants at greatest risk. Twenty-five participants were divided into concordant and discordant groups following electroencephalogram (EEG) measures recorded prior to a double-blind, placebo-controlled treatment trial. Three possible outcomes were examined: successful completion, dropout, and removal. Concordant (high perfusion correlate) participants had an 85% rate of successful completion, while discordant participants had a 15% rate of successful completion. Twenty-five percent of dropouts and 50% of participants removed were discordant (low perfusion correlate), while only 25% of those who completed were discordant. Failure to complete the trial was not explained by depression, craving, benzoylecgonine levels or quantitative electroencephalogram (QEEG) power; thus cordance may help identify attrition risk.

  18. Successful Application of Microarray Technology to Microdissected Formalin-Fixed, Paraffin-Embedded Tissue

    PubMed Central

    Coudry, Renata A.; Meireles, Sibele I.; Stoyanova, Radka; Cooper, Harry S.; Carpino, Alan; Wang, Xianqun; Engstrom, Paul F.; Clapper, Margie L.

    2007-01-01

    The establishment of a reliable method for using RNA from formalin-fixed, paraffin-embedded (FFPE) tissue would provide an opportunity to obtain novel gene expression data from the vast amounts of archived tissue. A custom-designed 22,000 oligonucleotide array was used in the present study to compare the gene expression profile of colonic epithelial cells isolated by laser capture microdissection from FFPE-archived samples with that of the same cell population from matched frozen samples, the preferred source of RNA. Total RNA was extracted from FFPE tissues, amplified, and labeled using the Paradise Reagent System. The quality of the input RNA was assessed by the Bioanalyzer profile, reverse transcriptase-polymerase chain reaction, and agarose gel electrophoresis. The results demonstrate that it is possible to obtain reliable microarray data from FFPE samples using RNA acquired by laser capture microdissection. The concordance between matched FFPE and frozen samples was evaluated and expressed as a Pearson’s correlation coefficient, with values ranging from 0.80 to 0.97. The presence of ribosomal RNA peaks in FFPE-derived RNA was reflected by a high correlation with paired frozen samples. A set of practical recommendations for evaluating the RNA integrity and quality in FFPE samples is reported. PMID:17251338

  19. Concordance between the quality of maternal and paternal parenting behavior within couples.

    PubMed

    Deschênes, Marie; Bernier, Annie; Jarry-Boileau, Véronique; St-Laurent, Diane

    2014-01-01

    There is compelling evidence that the quality of maternal and paternal parenting behavior bears critical importance for child development. Yet, less is known of the degree of similarity between maternal and paternal parenting behavior in families, and especially little is known about the factors that may explain variation in degrees of similarity. This article aims to examine (a) the concordance (similarity) between the quality of mothers' and fathers' interactive behavior with their child and (b) the sociodemographic determinants of this concordance. The sample included 74 families (mother, father, and their child). The quality of maternal and paternal interactive behavior was assessed independently, and rated with the Maternal Behavior Q-Sort (mother-infant, 12 months; D. R. Pederson et al., 1990) or the Mutually Responsive Orientation scale (father-toddler, 18 months; N. Aksan et al., 2006). The results indicated that the overall correlation between the quality of mothers' and fathers' behavior was moderate. The concordance was greater among higher socioeconomic status families or when interacting with a boy, but did not differ according to the presence or absence of siblings in the family.

  20. Utility of untimed single urine protein/creatinine ratio as a substitute for 24-h proteinuria for assessment of proteinuria in systemic lupus erythematosus.

    PubMed

    Medina-Rosas, Jorge; Gladman, Dafna D; Su, Jiandong; Sabapathy, Arthy; Urowitz, Murray B; Touma, Zahi

    2015-10-24

    In this study, we determined: (1) the utility of an untimed sample of urine protein/creatinine ratio (PCR) as a screening test for proteinuria, (2) its ability to accurately measure proteinuria, and (3) cutoff values for PCR predicting protein content in a 24-h urine collection sample (24hP) of 0.5, 1.0, and 2.0 g/day. Analysis was performed on data from a single lupus cohort (2008-2014). Proteinuria was measured in a 24hP and with PCR. On the basis of 24hP, samples were divided into 4 groups: group 1, <0.5 g/day; group 2, 0.5-0.99 g/day; group 3, 1-1.99 g/day; and group 4, ≥2 g/day. To determine the validity of PCR in screening for proteinuria, the Pearson correlation coefficient was determined for the urine samples with normal PCR (<0.05 g/mmol) and normal 24hP (<0.5 g/day). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PCR were calculated. To determine the ability of PCR to accurately measure the level of proteinuria, in addition to the correlation between 24hP and PCR, agreement was determined by intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plot between 24hP/24hC and PCR. The best cutoffs for PCR predicting a 24hP of 0.5, 1.0, and 2.0 g/day were determined with the receiver operating characteristic curve. The correlation of the samples with normal PCR as well as 24hP (n = 552) was 0.29 (p < 0.0001). PCR sensitivity and specificity against 24hP were 91 % and 83 %, respectively. The PPV was 82.5 %, and the NPV was 91.4 %. The correlation for all samples (n = 1233) was high, but low to moderate for groups 1, 2, 3, and 4. The agreement for all samples was appropriate but poor for groups 1, 2, 3, and 4. PCR cutoffs for 24hP of 0.5, 1.0, and 2.0 g/day were 0.08, 0.16, and 0.35 g/mmol, respectively. PCR can be used as a screening test for proteinuria, and the best cutoff value to predict a 24hP of 0.5 g/day is 0.08 g/mmol (800 mg/g). The accurate level of proteinuria should be measured by the gold standard test, 24hP.

  1. Correlates of parent-youth discordance about youth-witnessed violence: a brief report.

    PubMed

    Lewis, Terri; Thompson, Richard; Kotch, Jonathan B; Proctor, Laura J; Litrownik, Alan J; English, Diana J; Runyan, Desmond K; Wiley, Tisha R; Dubowitz, Howard

    2013-01-01

    Studies have consistently demonstrated a lack of agreement between youth and parent reports regarding youth-witnessed violence (YWV). However, little empirical investigation has been conducted on the correlates of disagreement. Concordance between youth and parents about YWV was examined in 766 parent-youth dyads from the Longitudinal Studies of Child Abuse and Neglect (LONGSCAN). Results showed that significantly more youth (42%) than parents (15%) reported YWV. Among the dyads in which at least one informant reported YWV (N = 344), we assessed whether youth delinquency, parental monitoring, parent-child relationship quality, history of child maltreatment, income, and parental depression were predictive of parent-youth concordance. Findings indicated that youth engagement in delinquent activities was higher in the groups in which the youth reported violence exposure. More empirical study is needed to assess correlates of agreement in high-risk youth to better inform associations found between exposures and outcomes as well as practice and policy for violence exposed youth.

  2. Using Google Street View to audit neighborhood environments.

    PubMed

    Rundle, Andrew G; Bader, Michael D M; Richards, Catherine A; Neckerman, Kathryn M; Teitler, Julien O

    2011-01-01

    Research indicates that neighborhood environment characteristics such as physical disorder influence health and health behavior. In-person audit of neighborhood environments is costly and time-consuming. Google Street View may allow auditing of neighborhood environments more easily and at lower cost, but little is known about the feasibility of such data collection. To assess the feasibility of using Google Street View to audit neighborhood environments. This study compared neighborhood measurements coded in 2008 using Street View with neighborhood audit data collected in 2007. The sample included 37 block faces in high-walkability neighborhoods in New York City. Field audit and Street View data were collected for 143 items associated with seven neighborhood environment constructions: aesthetics, physical disorder, pedestrian safety, motorized traffic and parking, infrastructure for active travel, sidewalk amenities, and social and commercial activity. To measure concordance between field audit and Street View data, percentage agreement was used for categoric measures and Spearman rank-order correlations were used for continuous measures. The analyses, conducted in 2009, found high levels of concordance (≥80% agreement or ≥0.60 Spearman rank-order correlation) for 54.3% of the items. Measures of pedestrian safety, motorized traffic and parking, and infrastructure for active travel had relatively high levels of concordance, whereas measures of physical disorder had low levels. Features that are small or that typically exhibit temporal variability had lower levels of concordance. This exploratory study indicates that Google Street View can be used to audit neighborhood environments. Copyright © 2011 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Weak Concordance between Fish and Macroinvertebrates in Mediterranean Streams

    PubMed Central

    Larsen, Stefano; Mancini, Laura; Pace, Giorgio; Scalici, Massimiliano; Tancioni, Lorenzo

    2012-01-01

    Although anthropogenic degradation of riverine systems stimulated a multi-taxon bioassessment of their ecological integrity in EU countries, specific responses of different taxonomic groups to human pressure are poorly investigated in Mediterranean rivers. Here, we assess if richness and composition of macroinvertebrate and fish assemblages show concordant variation along a gradient of anthropogenic pressure in 31 reaches across 13 wadeable streams in central Italy. Fish and invertebrate taxonomic richness was not correlated across sites. However, Mantel test showed that the two groups were significantly, albeit weakly, correlated even after statistically controlling for the effect of environmental variables and site proximity. Variance partitioning with partial Canonical Correspondence Analysis showed that the assemblages of the two groups were influenced by different set of environmental drivers: invertebrates were influenced by water organic content, channel and substratum features, while fish were related to stream temperature (mirroring elevation) and local land-use. Variance partitioning revealed the importance of biotic interactions between the two groups as a possible mechanisms determining concordance. Although significant, the congruence between the groups was weak, indicating that they should not be used as surrogate of each other for environmental assessments in these Mediterranean catchments. Indeed, both richness and patterns in nestedness (i.e. where depauperate locations host only a subset of taxa found in richer locations) appeared influenced by different environmental drivers suggesting that the observed concordance did not result from a co-loss of taxa along similar environmental gradients. As fish and macroinvertebrates appeared sensitive to different environmental factors, we argue that monitoring programmes should consider a multi-assemblage assessment, as also required by the Water Framework Directive. PMID:23251432

  4. Model for estimating enteric methane emissions from United States dairy and feedlot cattle.

    PubMed

    Kebreab, E; Johnson, K A; Archibeque, S L; Pape, D; Wirth, T

    2008-10-01

    Methane production from enteric fermentation in cattle is one of the major sources of anthropogenic greenhouse gas emission in the United States and worldwide. National estimates of methane emissions rely on mathematical models such as the one recommended by the Intergovernmental Panel for Climate Change (IPCC). Models used for prediction of methane emissions from cattle range from empirical to mechanistic with varying input requirements. Two empirical and 2 mechanistic models (COWPOLL and MOLLY) were evaluated for their prediction ability using individual cattle measurements. Model selection was based on mean square prediction error (MSPE), concordance correlation coefficient, and residuals vs. predicted values analyses. In dairy cattle, COWPOLL had the lowest root MSPE and greatest accuracy and precision of predicting methane emissions (correlation coefficient estimate = 0.75). The model simulated differences in diet more accurately than the other models, and the residuals vs. predicted value analysis showed no mean bias (P = 0.71). In feedlot cattle, MOLLY had the lowest root MSPE with almost all errors from random sources (correlation coefficient estimate = 0.69). The IPCC model also had good agreement with observed values, and no significant mean (P = 0.74) or linear bias (P = 0.11) was detected when residuals were plotted against predicted values. A fixed methane conversion factor (Ym) might be an easier alternative to diet-dependent variable Ym. Based on the results, the 2 mechanistic models were used to simulate methane emissions from representative US diets and were compared with the IPCC model. The average Ym in dairy cows was 5.63% of GE (range 3.78 to 7.43%) compared with 6.5% +/- 1% recommended by IPCC. In feedlot cattle, the average Ym was 3.88% (range 3.36 to 4.56%) compared with 3% +/- 1% recommended by IPCC. Based on our simulations, using IPCC values can result in an overestimate of about 12.5% and underestimate of emissions by about 9.8% for dairy and feedlot cattle, respectively. In addition to providing improved estimates of emissions based on diets, mechanistic models can be used to assess mitigation options such as changing source of carbohydrate or addition of fat to decrease methane, which is not possible with empirical models. We recommend national inventories use diet-specific Ym values predicted by mechanistic models to estimate methane emissions from cattle.

  5. Parent and Teacher Concordance on the Social Responsiveness Scale for Children with Autism.

    PubMed

    Azad, Gazi; Reisinger, Erica; Xie, Ming; Mandell, David S

    2016-09-01

    There are inconsistent findings regarding parent and teacher agreement on behavioral ratings of their children with autism. One possible reason for this inconsistency is that studies have not taken autism severity into account. This study examined parent and teacher concordance of social behavior based on symptom severity for children with autism. Participants were 123 parent-teacher dyads who completed the Social Responsiveness Scale. Symptom severity was assessed using the Autism Diagnostic Observation Schedule (ADOS). Results indicated that parent and teacher ratings were statistically significantly correlated at the beginning and end of the academic year, but only for severely affected children. Teacher report of social deficits was correlated with symptom severity as measured by the ADOS; parent report was not. These findings have implications for improving assessment procedures and parent-teacher collaboration.

  6. Facing haematopoietic stem-cell transplantation: do patients and their physicians agree regarding the prognosis?

    PubMed

    Grulke, Norbert; Bailer, Harald

    2010-10-01

    To evaluate the correlation and concordance between patients' and physicians' estimations of prognoses before initiation of the conditioning regimen for allogeneic haematopoietic stem-cell transplantation. A total of 123 patients and their attending physicians were asked to estimate a prognosis on a six-point scale. The patients were also asked to fill out questionnaires addressing their psychological state and coping. The mean prognostic estimations differed by 1.17 points (p<0.001), with the patients being more optimistic than the physicians. With respect to concordance: Pearson correlation r=0.024 (ns); unweighted kappa and kappa with linear weighting are 0.115 and 0.068, respectively. The prognostic estimates of the patients correlated with their psychological state, but not with the objective disease- or treatment-related variables, whereas the physicians' estimates were partially based on such objective factors. A clear significant association between actual survival and the physicians' estimates, but not the patients' estimates, was observed. If agreement regarding the prognosis exists, the relationship between physicians' and patients' estimates is probably non-linear. Assessing one's chances of being cured is a highly emotional task, and psychological processes such as denial or repression most likely play a decisive role. Moreover, collusion between the patient and physician may be inevitable in this situation. Whether it is desirable to gain concordance and who will benefit from such efforts must be discussed and empirically studied. Copyright © 2009 John Wiley & Sons, Ltd.

  7. Accurate method for preoperative estimation of the right graft volume in adult-to-adult living donor liver transplantation.

    PubMed

    Khalaf, H; Shoukri, M; Al-Kadhi, Y; Neimatallah, M; Al-Sebayel, M

    2007-06-01

    Accurate estimation of graft volume is crucial to avoid small-for-size syndrome following adult-to-adult living donor liver transplantation AALDLT). Herein, we combined radiological and mathematical approaches for preoperative assessment of right graft volume. The right graft volume was preoperatively estimated in 31 live donors using two methods: first, the radiological graft volume (RGV) by computed tomography (CT) volumetry and second, a calculated graft volume (CGV) obtained by multiplying the standard liver volume by the percentage of the right graft volume (given by CT). Both methods were compared to the actual graft volume (AGV) measured during surgery. The graft recipient weight ratio (GRWR) was also calculated using all three volumes (RGV, CGV, and AGV). Lin's concordance correlation coefficient (CCC) was used to assess the agreement between AGV and both RGV and CGV. This was repeated using the GRWR measurements. The mean percentage of right graft volume was 62.4% (range, 55%-68%; SD +/- 3.27%). The CCC between AGV and RGV versus CGV was 0.38 and 0.66, respectively. The CCC between GRWR using AGV and RGV versus CGV was 0.63 and 0.88, respectively (P < .05). According to the Landis and Kock benchmark, the CGV correlated better with AGV when compared to RGV. The better correlation became even more apparent when applied to GRWR. In our experience, CGV showed a better correlation with AGV compared with the RGV. Using CGV in conjunction with RGV may be of value for a more accurate estimation of right graft volume for AALDLT.

  8. Evaluation of facial attractiveness in black people according to the subjective facial analysis criteria.

    PubMed

    Melo, Andréa Reis de; Conti, Ana Cláudia de Castro Ferreira; Almeida-Pedrin, Renata Rodrigues; Didier, Victor; Valarelli, Danilo Pinelli; Capelozza Filho, Leopoldino

    2017-02-01

    The objective of this study was to evaluate the facial attractiveness in 30 black individuals, according to the Subjective Facial Analysis criteria. Frontal and profile view photographs of 30 black individuals were evaluated for facial attractiveness and classified as esthetically unpleasant, acceptable, or pleasant by 50 evaluators: the 30 individuals from the sample, 10 orthodontists, and 10 laymen. Besides assessing the facial attractiveness, the evaluators had to identify the structures responsible for the classification as unpleasant and pleasant. Intraexaminer agreement was assessed by using Spearman's correlation, correlation within each category using Kendall concordance coefficient, and correlation between the 3 categories using chi-square test and proportions. Most of the frontal (53. 5%) and profile view (54. 9%) photographs were classified as esthetically acceptable. The structures most identified as esthetically unpleasant were the mouth, lips, and face, in the frontal view; and nose and chin in the profile view. The structures most identified as esthetically pleasant were harmony, face, and mouth, in the frontal view; and harmony and nose in the profile view. The ratings by the examiners in the sample and laymen groups showed statistically significant correlation in both views. The orthodontists agreed with the laymen on the evaluation of the frontal view and disagreed on profile view, especially regarding whether the images were esthetically unpleasant or acceptable. Based on these results, the evaluation of facial attractiveness according to the Subjective Facial Analysis criteria proved to be applicable and to have a subjective influence; therefore, it is suggested that the patient's opinion regarding the facial esthetics should be considered in orthodontic treatmentplanning.

  9. Repeatability of quantitative FDG-PET/CT and contrast-enhanced CT in recurrent ovarian carcinoma: test-retest measurements for tumor FDG uptake, diameter, and volume.

    PubMed

    Rockall, Andrea G; Avril, Norbert; Lam, Raymond; Iannone, Robert; Mozley, P David; Parkinson, Christine; Bergstrom, Donald; Sala, Evis; Sarker, Shah-Jalal; McNeish, Iain A; Brenton, James D

    2014-05-15

    Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. Patients underwent two pretreatment baseline FDG-PET/CT (n = 21) and CECT (n = 20) at two clinical sites with different PET/CT instruments. Patients were included if they had at least one target lesion in the abdomen with a standardized uptake value (SUV) maximum (SUVmax) of ≥ 2.5 and a long axis diameter of ≥ 15 mm. Two independent reading methods were used to evaluate repeatability of tumor diameter and SUV uptake: on site and at an imaging clinical research organization (CRO). Tumor volume reads were only performed by CRO. In each reading set, target lesions were independently measured on sequential imaging. Median time between FDG-PET/CT was two days (range 1-7). For site reads, concordance correlation coefficients (CCC) for SUVmean, SUVmax, and tumor diameter were 0.95, 0.94, and 0.99, respectively. Repeatability coefficients were 16.3%, 17.3%, and 8.8% for SUVmean, SUVmax, and tumor diameter, respectively. Similar results were observed for CRO reads. Tumor volume CCC was 0.99 with a repeatability coefficient of 28.1%. There was excellent test-retest repeatability for FDG-PET/CT quantitative measurements across two sites and two independent reading methods. Cutoff values for determining change in SUVmean, SUVmax, and tumor volume establish limits to determine metabolic and/or volumetric response to treatment in platinum-sensitive relapsed ovarian cancer. ©2014 American Association for Cancer Research.

  10. Accuracy of a cow-side test for the diagnosis of hyperketonemia and hypoglycemia in lactating dairy cows.

    PubMed

    Macmillan, K; López Helguera, I; Behrouzi, A; Gobikrushanth, M; Hoff, B; Colazo, M G

    2017-12-01

    The objective of this study was to evaluate the use of a cow-side device (FreeStyle Precision Neo™) to diagnose ketosis and hypoglycemia based on measures of blood β-hydroxybutyrate (BHBA) and glucose. Eleven commercial dairy farms were visited and blood samples were taken from Holstein cows between 2 and 14days in milk, yielding 441 samples for BHBA analysis and 308 samples for glucose analysis. Concentrations of BHBA and glucose were measured in two ways, 1) using the cow-side device with whole blood immediately after sampling and 2) serum samples analyzed with a standard laboratory assay (Animal Health Laboratory, University of Guelph, Canada). The accuracy of the device was determined by comparing the results to the laboratory method as well as the ability to diagnose ketosis (BHBA ≥1.2mmol/L) and hypoglycemia (glucose <2.5mmol/L). The concordance correlation coefficient (CCC), Bland-Altman plot and Kappa coefficient were calculated to evaluate agreement between the 2 methods using SAS (version 9.3). The CCC was 0.92 for BHBA and 0.56 for glucose measurements. The 95% confidence intervals of the Bland-Altman plot encompassed 97% and 95% of the mean difference between methods for BHBA and glucose measurements, respectively. The Kappa coefficients were 0.78 for BHBA and 0.23 for glucose measurements. These results indicate that the cow-side device is accurate for rapid measurement of blood BHBA and diagnosis of ketosis on farms but is not accurate for measurement of blood glucose concentrations and diagnosis of hypoglycemia. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  11. Impact of the pan-Canadian Oncology Drug Review on provincial concordance with respect to cancer drug funding decisions and time to funding.

    PubMed

    Srikanthan, A; Mai, H; Penner, N; Amir, E; Laupacis, A; Sabharwal, M; Chan, K K W

    2017-10-01

    The pan-Canadian Oncology Drug Review (pcodr) was implemented in 2011 to address uneven drug coverage and lack of transparency with respect to the various provincial cancer drug review processes in Canada. We evaluated the impact of the pcodr on provincial decision concordance and time from Notice of Compliance (noc) to drug funding. In a retrospective review, Health Canada's Drug Product Database was used to identify new indications for cancer drugs between January 2003 and May 2014, and provincial formulary listings for drug-funding dates and decisions between 1 January 2003 and 31 December 2014 were retrieved. Multiple linear models and quantile regressions were used to evaluate changes in time to decision-making before and after the implementation of the pcodr. Agreement of decisions between provinces was evaluated using kappa statistics. Data were available from 9 provinces (all Canadian provinces except Quebec), identifying 88 indications that represented 51 unique cancer drugs. Two provinces lacked available data for all 88 indications at the time of data collection. Interprovincial concordance in drug funding decisions significantly increased after the pcodr's implementation (Brennan-Prediger coefficient: 0.54 pre-pcodr vs. 0.78 post-pcodr; p = 0.002). Nationwide, the median number of days from Health Canada's noc date to the date of funding significantly declined (to 393 days from 522 days, p < 0.001). Exploratory analyses excluding provinces with incomplete data did not change the results. After the implementation of the pcodr, greater concordance in cancer drug funding decisions between provinces and decreased time to funding decisions were observed.

  12. Development of a Physical Environmental Observational Tool for Dining Environments in Long-Term Care Settings.

    PubMed

    Chaudhury, Habib; Keller, Heather; Pfisterer, Kaylen; Hung, Lillian

    2017-11-10

    This paper presents the first standardized physical environmental assessment tool titled Dining Environment Audit Protocol (DEAP) specifically designed for dining spaces in care homes and reports the results of its psychometric properties. Items rated include: adequacy of lighting, glare, personal control, clutter, staff supervision support, restraint use, and seating arrangement option for social interaction. Two scales summarize the prior items and rate the overall homelikeness and functionality of the space. Ten dining rooms in three long-term care homes were selected for assessment. Data were collected over 11 days across 5 weeks. Two trained assessors completed DEAP independently on the same day. Interrater-reliability was completed for lighting, glare, space, homelike aspects, seating arrangements and the two summary scales, homelikeness and functionality of the space. For categorical measures, measure responses were dichotomized at logical points and Cohen's Kappa and concordance on ratings were determined. The two overall rating scales on homelikeness and functionality of space were found to be reliable intraclass correlation coefficient (ICC) (~0.7). The mean rating for homelikeness for Assessor 1 was 3.5 (SD 1.35) and for functionality of the room was 5.3. (SD 0.82; median 5.5). The findings indicate that the tool's interrater-reliability scores are promising. The high concordance on the overall scores for homelikeness and functionality is indicative of the strength of the individual items in generating a reliable global assessment score on these two important aspects of the dining space. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Assessing medicare beneficiaries’ strength‐of‐preference scores for health care options: how engaging does the elicitation technique need to be?

    PubMed Central

    Crump, Trafford; Llewellyn‐Thomas, Hilary A.

    2011-01-01

    Abstract Objective  The objective was to determine if participants’ strength‐of‐preference scores for elective health care interventions at the end‐of‐life (EOL) elicited using a non‐engaging technique are affected by their prior use of an engaging elicitation technique. Design  Medicare beneficiaries were randomly selected from a larger survey sample. During a standardized interview, participants considered four scenarios involving a choice between a relatively less‐ or more‐intense EOL intervention. For each scenario, participants indicated their favoured intervention, then used a 7‐point Leaning Scale (LS1) to indicate how strongly they preferred their favoured intervention relative to the alternative. Next, participants engaged in a Threshold Technique (TT), which, depending on the participant’s initially favoured intervention, systematically altered a particular attribute of the scenario until the participant switched preferences. Finally, they repeated the LS (LS2) to indicate how strongly they preferred their initially‐favoured intervention. Results  Two hundred and two participants were interviewed (189–198 were included in this study). The concordance of individual participants’ LS1 and LS2 scores was assessed using Kendall tau‐b correlation coefficients; scores of 0.74, 0.84, 0.85 and 0.89 for scenarios 1–4, respectively, were observed. Conclusion  Kendall tau‐b statistics indicate a high concordance between LS scores, implying that the interposing engaging TT exercise had no significant effects on the LS2 strength‐of‐preference scores. Future investigators attempting to characterize the distributions of strength‐of‐preference scores for EOL care from a large, diverse community could use non‐engaging elicitation methods. The potential limitations of this study require that further investigation be conducted into this methodological issue. PMID:21323819

  14. Validity and reliability of smartphone magnetometer-based goniometer evaluation of shoulder abduction--A pilot study.

    PubMed

    Johnson, Linda B; Sumner, Sean; Duong, Tina; Yan, Posu; Bajcsy, Ruzena; Abresch, R Ted; de Bie, Evan; Han, Jay J

    2015-12-01

    Goniometers are commonly used by physical therapists to measure range-of-motion (ROM) in the musculoskeletal system. These measurements are used to assist in diagnosis and to help monitor treatment efficacy. With newly emerging technologies, smartphone-based applications are being explored for measuring joint angles and movement. This pilot study investigates the intra- and inter-rater reliability as well as concurrent validity of a newly-developed smartphone magnetometer-based goniometer (MG) application for measuring passive shoulder abduction in both sitting and supine positions, and compare against the traditional universal goniometer (UG). This is a comparative study with repeated measurement design. Three physical therapists utilized both the smartphone MG and a traditional UG to measure various angles of passive shoulder abduction in a healthy subject, whose shoulder was positioned in eight different positions with pre-determined degree of abduction while seated or supine. Each therapist was blinded to the measured angles. Concordance correlation coefficients (CCCs), Bland-Altman plotting methods, and Analysis of Variance (ANOVA) were used for statistical analyses. Both traditional UG and smartphone MG were reliable in repeated measures of standardized joint angle positions (average CCC > 0.997) with similar variability in both measurement tools (standard deviation (SD) ± 4°). Agreement between the UG and MG measurements was greater than 0.99 in all positions. Our results show that the smartphone MG has equivalent reliability compared to the traditional UG when measuring passive shoulder abduction ROM. With concordant measures and comparable reliability to the UG, the newly developed MG application shows potential as a useful tool to assess joint angles. Published by Elsevier Ltd.

  15. Comparing 3-month recall to daily reporting of sexual behaviours.

    PubMed

    Mark, Kristen P; Smith, Rachel V; Young, April M; Crosby, Richard

    2017-05-01

    This study aimed to examine discrepancies between self-report methods and methodological issues related to sexual risk taking. We examined sexual behaviour assessed via 3-month electronic recall and by daily electronic reporting among a large cohort of patients attending STI clinics. STI clinic attenders (N= 628) aged 15 to 60 years reported on demographic information (at baseline), penile-vaginal sex acts, condom-unprotected penile-vaginal sex and STI history using 3-month recall and daily reports. Additionally, interviewer-participant match related to race and gender, as well as study site were considered as covariates. Concordance between recall and daily reports on penile-vaginal sex was moderately strong (Spearman's r (rs)=0.62; p<0.001). Comparison for reports for condom-unprotected penile-vaginal sex resulted in a correlation coefficient of 0.61 (p<0.001), also indicating moderately strong agreement between the two methods. Two generalised logit models were conducted to explain lack of strong concordance in penile-vaginal sex acts and condom-unprotected penile-vaginal sex. The odds of a female reporting higher frequency of sex in daily reports compared with recall were more than two times that of a male. Every five person increase in the number of lifetime sexual partners was associated with five times the odds of a discrepancy in reporting methods. Age was also significantly associated with unequal daily versus recall sex frequency reporting. Shifting focus to methodological considerations of technological reports can help ensure better investment of resources into sexual health research due to greater understanding of the methodological properties of data collection methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Overcoming barriers to population-based injury research: development and validation of an ICD-10–to–AIS algorithm

    PubMed Central

    Haas, Barbara; Xiong, Wei; Brennan-Barnes, Maureen; Gomez, David; Nathens, Avery B.

    2012-01-01

    Background Hospital administrative databases are a useful source of population-level data on injured patients; however, these databases use the International Classification of Diseases (ICD) system, which does not provide a direct means of estimating injury severity. We created and validated a crosswalk to derive Abbreviated Injury Scale (AIS) scores from injury-related diagnostic codes in the tenth revision of the ICD (ICD-10). Methods We assessed the validity of the crosswalk using data from the Ontario Trauma Registry Comprehensive Data Set (OTR-CDS). The AIS and Injury Severity Scores (ISS) derived using the algorithm were compared with those assigned by expert abstractors. We evaluated the ability of the algorithm to identify patients with AIS scores of 3 or greater. We used κ and intraclass correlation coefficients (ICC) as measures of concordance. Results In total, 10 431 patients were identified in the OTR-CDS. The algorithm accurately identified patients with at least 1 AIS score of 3 or greater (κ 0.65), as well as patients with a head AIS score of 3 or greater (κ 0.78). Mapped and abstracted ISS were similar; ICC across the entire cohort was 0.83 (95% confidence interval 0.81–0.84), indicating good agreement. When comparing mapped and abstracted ISS, the difference between scores was 10 or less in 87% of patients. Concordance between mapped and abstracted ISS was similar across strata of age, mechanism of injury and mortality. Conclusion Our ICD-10–to–AIS algorithm produces reliable estimates of injury severity from data available in administrative databases. This algorithm can facilitate the use of administrative data for population-based injury research in jurisdictions using ICD-10. PMID:22269308

  17. Overcoming barriers to population-based injury research: development and validation of an ICD10-to-AIS algorithm.

    PubMed

    Haas, Barbara; Xiong, Wei; Brennan-Barnes, Maureen; Gomez, David; Nathens, Avery B

    2012-02-01

    Hospital administrative databases are a useful source of population-level data on injured patients; however, these databases use the International Classification of Diseases (ICD) system, which does not provide a direct means of estimating injury severity. We created and validated a crosswalk to derive Abbreviated Injury Scale (AIS) scores from injury-related diagnostic codes in the tenth revision of the ICD (ICD-10). We assessed the validity of the crosswalk using data from the Ontario Trauma Registry Comprehensive Data Set (OTRCDS). The AIS and Injury Severity Scores (ISS) derived using the algorithm were compared with those assigned by expert abstractors. We evaluated the ability of the algorithm to identify patients with AIS scores of 3 or greater. We used κ and intraclass correlation coefficients (ICC) as measures of concordance. In total, 10 431 patients were identified in the OTRCDS. The algorithm accurately identified patients with at least 1 AIS score of 3 or greater (κ 0.65), as well as patients with a head AIS score of 3 or greater (κ 0.78). Mapped and abstracted ISS were similar; ICC across the entire cohort was 0.83 (95% confidence interval 0.81-0.84), indicating good agreement. When comparing mapped and abstracted ISS, the difference between scores was 10 or less in 87% of patients. Concordance between mapped and abstracted ISS was similar across strata of age, mechanism of injury and mortality. Our ICD-10-to-AIS algorithm produces reliable estimates of injury severity from data available in administrative databases. This algorithm can facilitate the use of administrative data for population-based injury research in jurisdictions using ICD-10.

  18. Systematized water content calculation in cartilage using T1-mapping MR estimations: design and validation of a mathematical model.

    PubMed

    Shiguetomi-Medina, J M; Ramirez-Gl, J L; Stødkilde-Jørgensen, H; Møller-Madsen, B

    2017-09-01

    Up to 80 % of cartilage is water; the rest is collagen fibers and proteoglycans. Magnetic resonance (MR) T1-weighted measurements can be employed to calculate the water content of a tissue using T1 mapping. In this study, a method that translates T1 values into water content data was tested statistically. To develop a predictive equation, T1 values were obtained for tissue-mimicking gelatin samples. 1.5 T MRI was performed using inverse angle phase and an inverse sequence at 37 (±0.5) °C. Regions of interest were manually delineated and the mean T1 value was estimated in arbitrary units. Data were collected and modeled using linear regression. To validate the method, articular cartilage from six healthy pigs was used. The experiment was conducted in accordance with the Danish Animal Experiment Committee. Double measurements were performed for each animal. Ex vivo, all water in the tissue was extracted by lyophilization, thus allowing the volume of water to be measured. This was then compared with the predicted water content via Lin's concordance correlation coefficient at the 95 % confidence level. The mathematical model was highly significant when compared to a null model (p < 0.0001). 97.3 % of the variation in water content can be explained by absolute T1 values. Percentage water content could be predicted as 0.476 + (T1 value) × 0.000193 × 100 %. We found that there was 98 % concordance between the actual and predicted water contents. The results of this study demonstrate that MR data can be used to predict percentage water contents of cartilage samples. 3 (case-control study).

  19. Estimations of One Repetition Maximum and Isometric Peak Torque in Knee Extension Based on the Relationship Between Force and Velocity.

    PubMed

    Sugiura, Yoshito; Hatanaka, Yasuhiko; Arai, Tomoaki; Sakurai, Hiroaki; Kanada, Yoshikiyo

    2016-04-01

    We aimed to investigate whether a linear regression formula based on the relationship between joint torque and angular velocity measured using a high-speed video camera and image measurement software is effective for estimating 1 repetition maximum (1RM) and isometric peak torque in knee extension. Subjects comprised 20 healthy men (mean ± SD; age, 27.4 ± 4.9 years; height, 170.3 ± 4.4 cm; and body weight, 66.1 ± 10.9 kg). The exercise load ranged from 40% to 150% 1RM. Peak angular velocity (PAV) and peak torque were used to estimate 1RM and isometric peak torque. To elucidate the relationship between force and velocity in knee extension, the relationship between the relative proportion of 1RM (% 1RM) and PAV was examined using simple regression analysis. The concordance rate between the estimated value and actual measurement of 1RM and isometric peak torque was examined using intraclass correlation coefficients (ICCs). Reliability of the regression line of PAV and % 1RM was 0.95. The concordance rate between the actual measurement and estimated value of 1RM resulted in an ICC(2,1) of 0.93 and that of isometric peak torque had an ICC(2,1) of 0.87 and 0.86 for 6 and 3 levels of load, respectively. Our method for estimating 1RM was effective for decreasing the measurement time and reducing patients' burden. Additionally, isometric peak torque can be estimated using 3 levels of load, as we obtained the same results as those reported previously. We plan to expand the range of subjects and examine the generalizability of our results.

  20. Translating plasma and whole blood fatty acid compositional data into the sum of eicosapentaenoic and docosahexaenoic acid in erythrocytes.

    PubMed

    Stark, Ken D; Aristizabal Henao, Juan J; Metherel, Adam H; Pilote, Louise

    2016-01-01

    Specific blood levels of eicosapentaenoic plus docosahexaenoic acid (EPA+DHA, wt% of total) in erythrocytes or "the omega-3 index" have been recommended for cardio-protection, but fatty acids are often measured in different blood fractions. The ability to estimate the % of EPA+DHA in erythrocytes from the fatty acid composition of other blood fractions would enable clinical assessments of omega-3 status when erythrocyte fractions are not available and increase the ability to compare blood levels of omega-3 fatty acids across clinical studies. The fatty acid composition of baseline plasma, erythrocytes and whole blood samples from participants (n=1104) in a prospective, multicenter study examining acute coronary syndrome were determined. The ability to predict the % of EPA+DHA in erythrocytes from other blood fractions were examined using bivariate and multiple linear regression modelling. Concordance analysis was also used to compare the actual erythrocytes EPA+DHA values to values estimated from other blood fractions. EPA+DHA in erythrocytes was significantly (p<0.001) correlated EPA+DHA in plasma (r(2)=0.54) and whole blood (r(2)=0.79). Using multiple linear regression to predict EPA+DHA in erythrocytes resulted in stronger coefficients of determination in both plasma (R(2)=0.70) and whole blood (R(2)=0.84). Concordance analyses indicated agreement between actual and estimated EPA+DHA in erythrocytes, although estimating from plasma fatty acids appears to require translation by categorization rather than by translation as continuous data. This study shows that the fatty acid composition of different blood fractions can be used to estimate erythrocyte EPA+DHA in a population with acute coronary syndrome. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Accuracy and feasibility of estimated tumour volumetry in primary gastric gastrointestinal stromal tumours: validation using semiautomated technique in 127 patients.

    PubMed

    Tirumani, Sree Harsha; Shinagare, Atul B; O'Neill, Ailbhe C; Nishino, Mizuki; Rosenthal, Michael H; Ramaiya, Nikhil H

    2016-01-01

    To validate estimated tumour volumetry in primary gastric gastrointestinal stromal tumours (GISTs) using semiautomated volumetry. In this IRB-approved retrospective study, we measured the three longest diameters in x, y, z axes on CTs of primary gastric GISTs in 127 consecutive patients (52 women, 75 men, mean age 61 years) at our institute between 2000 and 2013. Segmented volumes (Vsegmented) were obtained using commercial software by two radiologists. Estimate volumes (V1-V6) were obtained using formulae for spheres and ellipsoids. Intra- and interobserver agreement of Vsegmented and agreement of V1-6 with Vsegmented were analysed with concordance correlation coefficients (CCC) and Bland-Altman plots. Median Vsegmented and V1-V6 were 75.9, 124.9, 111.6, 94.0, 94.4, 61.7 and 80.3 cm(3), respectively. There was strong intra- and interobserver agreement for Vsegmented. Agreement with Vsegmented was highest for V6 (scalene ellipsoid, x ≠ y ≠ z), with CCC of 0.96 [95 % CI 0.95-0.97]. Mean relative difference was smallest for V6 (0.6 %), while it was -19.1 % for V5, +14.5 % for V4, +17.9 % for V3, +32.6 % for V2 and +47 % for V1. Ellipsoidal approximations of volume using three measured axes may be used to closely estimate Vsegmented when semiautomated techniques are unavailable. Estimation of tumour volume in primary GIST using mathematical formulae is feasible. Gastric GISTs are rarely spherical. Segmented volumes are highly concordant with three axis-based scalene ellipsoid volumes. Ellipsoid volume can be used as an alternative for automated tumour volumetry.

  2. Imaging Signs in Spontaneous Intracranial Hypotension: Prevalence and Relationship to CSF Pressure.

    PubMed

    Kranz, P G; Tanpitukpongse, T P; Choudhury, K R; Amrhein, T J; Gray, L

    2016-07-01

    Patients with spontaneous intracranial hypotension often exhibit low CSF pressure and changes on brain MR imaging and/or evidence of CSF leak on myelography. We investigated whether individual imaging signs of spontaneous intracranial hypotension correlate with measured CSF pressure and how frequently these 2 markers of spontaneous intracranial hypotension were concordant. We performed a retrospective, cross-sectional study of 99 subjects with spontaneous intracranial hypotension. Prevalence of brain and myelographic imaging signs of spontaneous intracranial hypotension was recorded. CSF pressure among subjects with or without individual imaging signs was compared by using a 2-tailed t test and ANOVA. Concordance between low CSF pressure (≤6 cm H2O) and imaging was defined as the presence of the sign in a subject with low CSF pressure or absence of the sign when pressure was not low. Dural enhancement, brain sagging, and venous distension sign were present in 83%, 61%, and 75% of subjects, respectively, and myelographic evidence of CSF leak was seen in 55%. Marginal correlations between CSF pressure and brain sagging (P = .046) and the venous distension sign (P = .047) were found. Dural enhancement and myelographic evidence of leak were not significantly correlated with CSF pressure. Rates of concordance between imaging signs and low CSF pressure were generally low, ranging from 39% to 55%. Brain and myelographic signs of spontaneous intracranial hypotension correlate poorly with CSF pressure. These findings reinforce the need to base the diagnosis of spontaneous intracranial hypotension on multiple diagnostic criteria and suggest the presence of patient-specific variables that influence CSF pressure in these individuals. © 2016 by American Journal of Neuroradiology.

  3. Accurate determination of high-risk coronary lesion type by multidetector cardiac computed tomography.

    PubMed

    Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P

    2008-07-01

    Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.

  4. [Accelerometry does not match with self-reported physical activity and sedentary behaviors in Mexican children].

    PubMed

    Ayala-Guzmán, César Iván; Ramos-Ibáñez, Norma; Ortiz-Hernández, Luis

    An accurate assessment of physical activity in schoolchildren is necessary to implement strategies that promote active lifestyles. The objective of this study was to validate a self-administered questionnaire to assess physical activity and sedentary behaviors and to analyze differences in the validity according to nutritional status in Mexican schoolchildren. Schoolchildren of 8-12 years of age answered a self-report physical activity and sedentary behaviors questionnaire to evaluate sedentary and light physical activity (SLPA) and moderate to vigorous physical activity (MVPA). The data of children who wore a triaxial accelerometer days was analyzed. Concordance between both methods to determine the time schoolchildren spend watching television was assessed using intraclass correlation coefficients and Bland-Altman method. The estimation of MVPA by questionnaires was higher than that of accelerometers by 117.6minutes per week, and the estimation of SLPA was lower by 1,924.7minutes per week. No correlation between the time assessed by accelerometers and the time reported in the questionnaires for SLPA and MVPA was detected. In normal-weighted children, a low correlation between the time dedicated to play videogames with sedentary activities (r ic =0.29, p=0.031) assessed by accelerometers was observed. Schoolchildren over-estimate MVPA and under-estimate SLPA. Body weight can be a factor influencing such bias. Copyright © 2017 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Cross ranking of cities and regions: population versus income

    NASA Astrophysics Data System (ADS)

    Cerqueti, Roy; Ausloos, Marcel

    2015-07-01

    This paper explores the relationship between the inner economical structure of communities and their population distribution through a rank-rank analysis of official data, along statistical physics ideas within two techniques. The data is taken on Italian cities. The analysis is performed both at a global (national) and at a more local (regional) level in order to distinguish ‘macro’ and ‘micro’ aspects. First, the rank-size rule is found not to be a standard power law, as in many other studies, but a doubly decreasing power law. Next, the Kendall τ and the Spearman ρ rank correlation coefficients which measure pair concordance and the correlation between fluctuations in two rankings, respectively,—as a correlation function does in thermodynamics, are calculated for finding rank correlation (if any) between demography and wealth. Results show non only global disparities for the whole (country) set, but also (regional) disparities, when comparing the number of cities in regions, the number of inhabitants in cities and that in regions, as well as when comparing the aggregated tax income of the cities and that of regions. Different outliers are pointed out and justified. Interestingly, two classes of cities in the country and two classes of regions in the country are found. ‘Common sense’ social, political, and economic considerations sustain the findings. More importantly, the methods show that they allow to distinguish communities, very clearly, when specific criteria are numerically sound. A specific modeling for the findings is presented, i.e. for the doubly decreasing power law and the two phase system, based on statistics theory, e.g. urn filling. The model ideas can be expected to hold when similar rank relationship features are observed in fields. It is emphasized that the analysis makes more sense than one through a Pearson Π value-value correlation analysis

  6. Correlation between computerised findings and Newman's scaling on vascularity using power Doppler ultrasonography imaging and its predictive value in patients with plantar fasciitis

    PubMed Central

    Chen, H; Ho, H M; Ying, M; Fu, S N

    2012-01-01

    Objectives The purpose of this study was to correlate findings on small vessel vascularity between computerised findings and Newman's scaling using power Doppler ultrasonography (PDU) imaging and its predictive value in patients with plantar fasciitis. Methods PDU was performed on 44 patients (age range 30–66 years; mean age 48 years) with plantar fasciitis and 46 healthy subjects (age range 18–61 years; mean age 36 years). The vascularity was quantified using ultrasound images by a customised software program and graded by Newman's grading scale. Vascular index (VI) was calculated from the software program as the ratio of the number of colour pixels to the total number of pixels within a standardised selected area of proximal plantar fascia. The 46 healthy subjects were examined on 2 occasions 7–10 days apart, and 18 of them were assessed by 2 examiners. Statistical analyses were performed using intraclass correlation coefficient and linear regression analysis. Results Good correlation was found between the averaged VI ratios and Newman's qualitative scale (ρ = 0.70; p<0.001). Intratester and intertester reliability were 0.89 and 0.61, respectively. Furthermore, higher VI was correlated with less reduction in pain after physiotherapeutic intervention. Conclusions The computerised VI not only has a high level of concordance with the Newman grading scale but is also reliable in reflecting the vascularity of proximal plantar fascia, and can predict pain reduction after intervention. This index can be used to characterise the changes in vascularity of patients with plantar fasciitis, and it may also be helpful for evaluating treatment and monitoring the progress after intervention in future studies. PMID:22167513

  7. How Accurate are Self-Reports? An Analysis of Self-Reported Healthcare Utilization and Absence When Compared to Administrative Data

    PubMed Central

    Short, Meghan E.; Pei, Xiaofei; Tabrizi, Maryam J.; Ozminkowski, Ronald J.; Gibson, Teresa B.; DeJoy, Dave M.; Wilson, Mark G.

    2009-01-01

    Objective To determine the accuracy of self-reported healthcare utilization and absence reported on health risk assessments (HRAs) against administrative claims and human resource records. Methods Self-reported values of healthcare utilization and absenteeism were analyzed for concordance to administrative claims values. Percent agreement, Pearson’s correlations, and multivariate logistic regression models examined the level of agreement and characteristics of participants with concordance. Results Self-report and administrative data showed greater concordance for monthly compared to yearly healthcare utilization metrics. Percent agreement ranged from 30 to 99% with annual doctor visits having the lowest percent agreement. Younger people, males, those with higher education, and healthier individuals more accurately reported their healthcare utilization and absenteeism. Conclusions Self-reported healthcare utilization and absenteeism may be used as a proxy when medical claims and administrative data are unavailable, particularly for shorter recall periods. PMID:19528832

  8. Precision and accuracy of age estimates obtained from anal fin spines, dorsal fin spines, and sagittal otoliths for known-age largemouth bass

    USGS Publications Warehouse

    Klein, Zachary B.; Bonvechio, Timothy F.; Bowen, Bryant R.; Quist, Michael C.

    2017-01-01

    Sagittal otoliths are the preferred aging structure for Micropterus spp. (black basses) in North America because of the accurate and precise results produced. Typically, fisheries managers are hesitant to use lethal aging techniques (e.g., otoliths) to age rare species, trophy-size fish, or when sampling in small impoundments where populations are small. Therefore, we sought to evaluate the precision and accuracy of 2 non-lethal aging structures (i.e., anal fin spines, dorsal fin spines) in comparison to that of sagittal otoliths from known-age Micropterus salmoides (Largemouth Bass; n = 87) collected from the Ocmulgee Public Fishing Area, GA. Sagittal otoliths exhibited the highest concordance with true ages of all structures evaluated (coefficient of variation = 1.2; percent agreement = 91.9). Similarly, the low coefficient of variation (0.0) and high between-reader agreement (100%) indicate that age estimates obtained from sagittal otoliths were the most precise. Relatively high agreement between readers for anal fin spines (84%) and dorsal fin spines (81%) suggested the structures were relatively precise. However, age estimates from anal fin spines and dorsal fin spines exhibited low concordance with true ages. Although use of sagittal otoliths is a lethal technique, this method will likely remain the standard for aging Largemouth Bass and other similar black bass species.

  9. First international collaborative study to evaluate rabies antibody detection method for use in monitoring the effectiveness of oral vaccination programmes in fox and raccoon dog in Europe.

    PubMed

    Wasniewski, M; Almeida, I; Baur, A; Bedekovic, T; Boncea, D; Chaves, L B; David, D; De Benedictis, P; Dobrostana, M; Giraud, P; Hostnik, P; Jaceviciene, I; Kenklies, S; König, M; Mähar, K; Mojzis, M; Moore, S; Mrenoski, S; Müller, T; Ngoepe, E; Nishimura, M; Nokireki, T; Pejovic, N; Smreczak, M; Strandbygaard, B; Wodak, E; Cliquet, F

    2016-12-01

    The most effective and sustainable method to control and eliminate rabies in wildlife is the oral rabies vaccination (ORV) of target species, namely foxes and raccoon dogs in Europe. According to WHO and OIE, the effectiveness of oral vaccination campaigns should be regularly assessed via disease surveillance and ORV antibody monitoring. Rabies antibodies are generally screened for in field animal cadavers, whose body fluids are often of poor quality. Therefore, the use of alternative methods such as the enzyme-linked immunosorbent assay (ELISA) has been proposed to improve reliability of serological results obtained on wildlife samples. We undertook an international collaborative study to determine if the commercial BioPro ELISA Rabies Ab kit is a reliable and reproducible tool for rabies serological testing. Our results reveal that the overall specificity evaluated on naive samples reached 96.7%, and the coefficients of concordance obtained for fox and raccoon dog samples were 97.2% and 97.5%, respectively. The overall agreement values obtained for the four marketed oral vaccines used in Europe were all equal to or greater than 95%. The coefficients of concordance obtained by laboratories ranged from 87.2% to 100%. The results of this collaborative study show good robustness and reproducibility of the BioPro ELISA Rabies Ab kit. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Comparison of human and electronic observation for the measurement of compliance with hand hygiene.

    PubMed

    Filho, Miguel Almeida O; Marra, Alexandre R; Magnus, Thyago Pereira; Rodrigues, Rodrigo Dias; Prado, Marcelo; de Souza Santini, Tales Roberto; da Silva Victor, Elivane; Ishibe, Eder Issao; Pavão Dos Santos, Oscar Fernando; Edmond, Michael B

    2014-11-01

    Monitoring of hand hygiene is an important part of the improvement of hospital quality indicators. This study was prospectively performed over a 14-week (electronic observer) period from December 3, 2013-March 9, 2014, to evaluate hand hygiene compliance in an adult step-down unit. We compared electronic handwash counters with the application of radiofrequency identification (RFID - ZigBee; i-Healthsys, São Carlos, Brazil) (electronic observer), which counts each activation of the alcohol gel dispenser to direct observation (human observer) using the iScrub application. For the overall time period of simultaneous electronic and human observation, we found that the electronic observer identified 414 hand hygiene episodes, whereas the human observers identified 448 episodes. Therefore, we found 92% (95% confidence interval [CI], 90%-95%) overall concordance (414/448), with an intraclass correlation coefficient of .87 (95% CI, 0.77-0.92). Our RFID (ZigBee) system showed good accuracy (92%) and is a useful method to monitor hand hygiene compliance. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. [Simplified indicator of socioeconomic status in short surveys: a proposal based on assets and services].

    PubMed

    Díaz-Acosta, Rodrigo; Shiba-Matsumoto, Andrey Ryo; Gutiérrez, Juan Pablo

    2015-01-01

    To develop a socioeconomic index for brief surveys that allows a classification in relation to a reference population with a parsimonious approach. A socioeconomic index was created using assets and use of services indicators to predict income level within a national representative survey of income (ENIGH, National Survey of Households Income and Expenditures) and then tested with data from a survey among key populations (men who have sex with men/transvestite, transgender, transsexual/female sex workers) and compared to an already published indicator. The concordance for quintiles 1, 2, 3, 4, and 5 between the two indexes were 94, 94, 82, 83, and 89%, respectively. The Spearman's rank correlation coefficient was 0.85. The proposed parsimonious index captures the socioeconomic level heterogeneity in the MSM/TTT/FSW survey. The use of this index is suggested for short surveys because of the next advantages: a) it uses dichotomic variables; b) the variables used do not imply the fulfillment of any statistical assumption; c) it is easily calculated; d) it can be used for comparing groups.

  12. Reproducibility of electronic tooth colour measurements.

    PubMed

    Ratzmann, Anja; Klinke, Thomas; Schwahn, Christian; Treichel, Anja; Gedrange, Tomasz

    2008-10-01

    Clinical methods of investigation, such as tooth colour determination, should be simple, quick and reproducible. The determination of tooth colours usually relies upon manual comparison of a patient's tooth colour with a colour ring. After some days, however, measurement results frequently lack unequivocal reproducibility. This study aimed to examine an electronic method for reliable colour measurement. The colours of the teeth 14 to 24 were determined by three different examiners in 10 subjects using the colour measuring device Shade Inspector. In total, 12 measurements per tooth were taken. Two measurement time points were scheduled to be taken, namely at study onset (T(1)) and after 6 months (T(2)). At either time point, two measurement series per subject were taken by the different examiners at 2-week intervals. The inter-examiner and intra-examiner agreement of the measurement results was assessed. The concordance for lightness and colour intensity (saturation) was represented by the intra-class correlation coefficient. The categorical variable colour shade (hue) was assessed using the kappa statistic. The study results show that tooth colour can be measured independently of the examiner. Good agreement was found between the examiners.

  13. A new correlation coefficient for bivariate time-series data

    NASA Astrophysics Data System (ADS)

    Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf

    2014-11-01

    The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.

  14. Analysis of reliability of professor recommendation letters based on concordance with self-introduction letter.

    PubMed

    Kim, Sang Hyun

    2013-12-01

    The purpose of this study was to examine the concordance between a checklist's categories of professor recommendation letters and characteristics of the self-introduction letter. Checklists of professor recommendation letters were analyzed and classified into cognitive, social, and affective domains. Simple correlation was performed to determine whether the characteristics of the checklists were concordant with those of the self-introduction letter. The difference in ratings of the checklists by pass or fail grades was analyzed by independent sample t-test. Logistic regression analysis was performed to determine whether a pass or fail grade was influenced by ratings on the checklists. The Cronbach alpha value of the checklists was 0.854. Initiative, as an affective domain, in the professor's recommendation letter was highly ranked among the six checklist categories. Self-directed learning in the self-introduction letter was influenced by a pass or fail grade by logistic regression analysis (p<0.05). Successful applicants received higher ratings than those who failed in every checklist category, particularly in problem-solving ability, communication skills, initiative, and morality (p<0.05). There was a strong correlation between cognitive and affective characteristics in the professor recommendation letters and the sum of all characteristics in the self-introduction letter.

  15. Prediction of appendicular skeletal and fat mass in children: excellent concordance of dual-energy X-ray absorptiometry and magnetic resonance imaging.

    PubMed

    Bridge, Pascale; Pocock, Nicholas A; Nguyen, Tuan; Munns, Craig; Cowell, Christopher T; Thompson, Martin W

    2009-09-01

    Body composition studies in children have great potential to help understand the aetiology and evolution of acute and chronic. diseases. To validate appendicular lean soft tissue mass (LSTM) and fat mass (FM) measured using dual energy X-ray absorptiometry (DXA), with magnetic resonance imaging (MRI) as the reference standard, in healthy peri-pubertal adolescents. Peri-pubertal Caucasian children (n = 74) aged 11-14 years were evaluated. DXA LSTM and FM of the mid third femur were measured and skeletal muscle mass (SM) and FM of the same region were measured on the same day by MRI. There was a strong correlation between MRI SM and DXA LSTM (r2 = 0.98, index of concordance [C] = 0.91). DXA estimation of LSTM exceeded MRI SM by a mean of 189 g, from 6-371 g (p < 0.0001). The discordance between DXA and MRI significantly increased with the absolute value (r = 0.27; p = 0.024). FM was highly correlated (r = 0.98) with a high index of concordance (C = 0.97). This study validates the use of DXA in LSTM measurement in children, confirming its potential in clinical and research roles in paediatric diseases affecting and related to body composition.

  16. Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.

    PubMed

    Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J

    2008-06-18

    Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.

  17. Tests of Hypotheses Arising In the Correlated Random Coefficient Model*

    PubMed Central

    Heckman, James J.; Schmierer, Daniel

    2010-01-01

    This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148

  18. Concordance of preclinical and clinical pharmacology and toxicology of therapeutic monoclonal antibodies and fusion proteins: cell surface targets

    PubMed Central

    Bugelski, Peter J; Martin, Pauline L

    2012-01-01

    Monoclonal antibodies (mAbs) and fusion proteins directed towards cell surface targets make an important contribution to the treatment of disease. The purpose of this review was to correlate the clinical and preclinical data on the 15 currently approved mAbs and fusion proteins targeted to the cell surface. The principal sources used to gather data were: the peer reviewed Literature; European Medicines Agency ‘Scientific Discussions’; and the US Food and Drug Administration ‘Pharmacology/Toxicology Reviews’ and package inserts (United States Prescribing Information). Data on the 15 approved biopharmaceuticals were included: abatacept; abciximab; alefacept; alemtuzumab; basiliximab; cetuximab; daclizumab; efalizumab; ipilimumab; muromonab; natalizumab; panitumumab; rituximab; tocilizumab; and trastuzumab. For statistical analysis of concordance, data from these 15 were combined with data on the approved mAbs and fusion proteins directed towards soluble targets. Good concordance with human pharmacodynamics was found for mice receiving surrogates or non-human primates (NHPs) receiving the human pharmaceutical. In contrast, there was poor concordance for human pharmacodynamics in genetically deficient mice and for human adverse effects in all three test systems. No evidence that NHPs have superior predictive value was found. PMID:22168282

  19. Quality of Life as reported by school children and their parents: a cross-sectional survey

    PubMed Central

    Jozefiak, Thomas; Larsson, Bo; Wichstrøm, Lars; Mattejat, Fritz; Ravens-Sieberer, Ulrike

    2008-01-01

    Background Comprehensive evidence exists regarding the discrepancy between children's reports and parents' by proxy reports on emotional and behavioural problems. However, little is yet known about factors influencing the extent to which child self- and parent by proxy reports differ in respect of child Quality of Life (QoL). The aim of the study was to investigate the degree of discrepancy between child and parent by proxy reports as measured by two different QoL instruments. Methods A representative Norwegian sample of 1997 school children aged 8–16 years, and their parents were studied using the Inventory of Life Quality (ILC) and the 'Kinder Lebensqualität Fragebogen' (KINDL). Child and parent reports were compared by t-test, and correlations were calculated by Pearson product moment coefficient. Psychometric aspects were examined in regard to both translated QoL instruments (internal consistency by Cronbach's alpha and test-retest reliability by intraclass correlation coefficients). Results Parents evaluated the QoL of their children significantly more positively than did the children. Correlations between mother-child and father-child reports were significant (p < 0.01) and similar but low to moderate (r = 0.32; and r = 0.30, respectively, for the KINDL, and r = 0.30 and r = 0.26, respectively, for the ILC). Mother and father reports correlated moderately highly (r = 0.54 and r = 0.61 for the KINDL and ILC, respectively). No significant differences between correlations of mother-daughter/son and father-daughter/son pairs in regard to reported child QoL were observed on either of the two instruments. Conclusion In the present general population sample, parents reported higher child QoL than did their children. Concordance between child and parent by proxy report was low to moderate. The level of agreement between mothers and fathers in regard to their child's QoL was moderate. No significant impact of parent and child gender in regard to agreement in ratings of child QoL was found. Both the child and parent versions of the Norwegian translations of the KINDL and ILC can be used in surveys of community populations, but in regard to the self-report of 9–10 years old children, only the KINDL total QoL scale or the ILC are recommended. PMID:18489777

  20. Radiographic angles in hallux valgus: differences between measurements made manually and with a computerized program.

    PubMed

    Piqué-Vidal, Carlos; Maled-García, Ignaci; Arabi-Moreno, Juanjo; Vila, Joan

    2006-03-01

    The objective of this study was to compare angular measurements in the evaluation of hallux valgus deformities using a goniometer and a computerized program to assess degree of concordance between the two methods and determine the reliability of manual measurements. Angles measured included the hallux valgus angle (HVA), the intermetatarsal angle (IMA), the distal metatarsal articular angle (DMAA), and the proximal phalangeal articular angle (PPAA), also called the hallux valgus interphalangeus angle or interphalangeal angle. Measurements were made on preoperative weightbearing radiographs in 176 patients with symptomatic hallux valgus. Manual measurements were made with a goniometer by an orthopaedic surgeon. An independent experienced technician used digitized images to perform angular measurements with the Autocad software program (Autodesk Inc., San Rafael, CA). HVA values obtained with the two techniques were similar. However, significantly higher mean values were obtained with the Autocad for the IMA and PPAA measurements, and higher mean values were obtained for the DMAA measurement with the manual technique. Whereas differences were more or less randomly distributed for the HVA, in the remaining patients, measurements were clearly related to the measurement technique, i.e., for the DMAA, the manual technique had a tendency to show higher values, and for the IMA and PPAA the manual technique showed lower values than the computer. Correlations between both techniques for the different angular measurements were as follows: HVA, -0.179 (p = 0.018); DMMA, -0.294 (p < 0.001); PPAA, -0.876 (p < 0.001); and IMA, -0.661 (p < 0.001). The intraclass correlation coefficient (ICC) showed that the concordance between manual and Autocad angular measurements was excellent for the HVA (ICC = 0.89) and DMAA (ICC = 0.80) and very poor for the PPAA (ICC = 0.11) and IMA (ICC = 0.42). Angular measurements made on weightbearing radiographs with the Autocad in patients with hallux valgus deformities were more reliable than those made with a goniometer. Although for large angles, such as HVA and DMAA, results obtained with both measurement techniques were similar. Manual measurements, however, may underestimate the true values of the smaller IMA and PPAA angles.

  1. Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.

    PubMed

    Amendola, Alessandra; Pisciotta, Maria; Aleo, Loredana; Ferraioli, Valeria; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2016-09-01

    The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P < 0.0001) and mean differences of measurement, conducted according to Bland-Altman method, was low (0.115 log10  copies/ml). The Aptima HIV quantified the WHO 3rd HIV-1 International Standard diluted from 2000 to 31 cp/ml (5,700-88 IU/ml) at expected values with excellent linearity (R(2)  > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Quantification of Estrogen Receptor-Alpha Expression in Human Breast Carcinomas With a Miniaturized, Low-Cost Digital Microscope: A Comparison with a High-End Whole Slide-Scanner

    PubMed Central

    Holmström, Oscar; Linder, Nina; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Turkki, Riku; Joensuu, Heikki; Isola, Jorma; Diwan, Vinod; Lundin, Johan

    2015-01-01

    Introduction A significant barrier to medical diagnostics in low-resource environments is the lack of medical care and equipment. Here we present a low-cost, cloud-connected digital microscope for applications at the point-of-care. We evaluate the performance of the device in the digital assessment of estrogen receptor-alpha (ER) expression in breast cancer samples. Studies suggest computer-assisted analysis of tumor samples digitized with whole slide-scanners may be comparable to manual scoring, here we study whether similar results can be obtained with the device presented. Materials and Methods A total of 170 samples of human breast carcinoma, immunostained for ER expression, were digitized with a high-end slide-scanner and the point-of-care microscope. Corresponding regions from the samples were extracted, and ER status was determined visually and digitally. Samples were classified as ER negative (<1% ER positivity) or positive, and further into weakly (1–10% positivity) and strongly positive. Interobserver agreement (Cohen’s kappa) was measured and correlation coefficients (Pearson’s product-momentum) were calculated for comparison of the methods. Results Correlation and interobserver agreement (r = 0.98, p < 0.001, kappa = 0.84, CI95% = 0.75–0.94) were strong in the results from both devices. Concordance of the point-of-care microscope and the manual scoring was good (r = 0.94, p < 0.001, kappa = 0.71, CI95% = 0.61–0.80), and comparable to the concordance between the slide scanner and manual scoring (r = 0.93, p < 0.001, kappa = 0.69, CI95% = 0.60–0.78). Fourteen (8%) discrepant cases between manual and device-based scoring were present with the slide scanner, and 16 (9%) with the point-of-care microscope, all representing samples of low ER expression. Conclusions Tumor ER status can be accurately quantified with a low-cost imaging device and digital image-analysis, with results comparable to conventional computer-assisted or manual scoring. This technology could potentially be expanded for other histopathological applications at the point-of-care. PMID:26659386

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, L; Ziemer, B; Lipinski, J

    Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosismore » level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.« less

  4. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery.

    PubMed

    Park, Yong-Hee; Lee, Ji-Hyun; Song, Hyun-Gul; Byon, Hyo-Jin; Kim, Hee-Soo; Kim, Jin-Tae

    2012-12-01

    The most common method for determining the hemoglobin concentration is to draw blood from a patient. However, the Radical-7 Pulse CO-Oximeter (Masimo Corporation, Irvine, CA) can noninvasively provide continuous hemoglobin concentration (SpHb). In our study we compared noninvasive measurements of SpHb with simultaneous laboratory measurements of total hemoglobin in arterial blood samples taken from children (tHb). Arterial blood samples were analyzed using a laboratory CO-oximeter, and SpHb was simultaneously recorded in pediatric patients undergoing neurosurgery. When patients met the criteria for hypovolemia, 10 mL/kg of colloids or red blood cells were administered over 10 minutes. SpHb and tHb data were collected before and after intravascular volume resuscitation. The relationship between SpHb and tHb was assessed using a 4-quadrant plot, linear regression, mixed-effect model, and modified Bland-Altman analyses. One hundred nineteen paired samples were analyzed. The correlation coefficient between SpHb and tHb was 0.53 (P < 0.001), whereas that of change in SpHb versus change in tHb was 0.75 (P < 0.001). The average difference (bias) between tHb and SpHb was 0.90 g/dL (95% confidence interval [CI], 0.48-1.32 g/dL) and 1 standard deviation of the difference (sd) was 1.35 g/dL. The concordance rate (a measure of the number of data points that are in 1 of the 2 quadrants of agreement) determined using a 4-quadrant plot was 93%. The correlation coefficient between SpHb and tHb after intravascular volume resuscitation was 0.58 (P < 0.001), whereas that of changes in SpHb and tHb was 0.87 (P < 0.001). The bias immediately after volume resuscitation was 1.18 g/dL (95% CI, 0.81-1.55 g/dL), and sd was 1.28 g/dL with a concordance rate of 94.4%. The bias was -0.03 g/dL when tHb was ≥11 g/dL, which was significantly lower in comparison with biases when tHb <9 g/dL (1.24 g/dL) and tHb was 9-11 g/dL (1.17 g/dL) (P = 0.004). The Radical-7 Pulse CO-Oximeter can be useful as a trend monitor in children during surgery even immediately after intravascular volume expanders are administered. However, it is advisable to confirm the baseline hemoglobin level and to consider the influence of tHb level on the bias. In addition, one should be cautious with regard to using SpHb alone when making transfusion decisions.

  5. Modified Regression Correlation Coefficient for Poisson Regression Model

    NASA Astrophysics Data System (ADS)

    Kaengthong, Nattacha; Domthong, Uthumporn

    2017-09-01

    This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).

  6. Surgical site infections among high-risk patients in clean-contaminated head and neck reconstructive surgery: concordance with preoperative oral flora.

    PubMed

    Yang, Ching-Hsiang; Chew, Khong-Yik; Solomkin, Joseph S; Lin, Pao-Yuan; Chiang, Yuan-Cheng; Kuo, Yur-Ren

    2013-12-01

    Salivary contamination of surgical wounds in clean-contaminated head and neck surgery with free flap reconstruction remains a major cause of infection and leads to significant morbidity. This study investigates the correlation between intraoral flora and surgical site infections (SSIs) among high-risk head and neck cancer patients undergoing resection and free flap reconstruction. One hundred twenty-nine patients were identified as being at high risk for infective complications based on cancer stage, tumor size, comorbid factors, and extent of reconstruction. All patients had intraoral swab cultures before surgery. Patients with culture-confirmed SSI after surgery were chosen for analysis, using the κ index and its 95% confidence interval for concordance analysis. All patients received clindamycin and gentamicin for antibiotic prophylaxis for 5 days. Antibiotic susceptibility testing of all isolates was obtained and analyzed. Thirty-seven patients experienced SSI, or an infection rate of 28.3%, occurring at a mean of 9.3 postoperative days. The overall concordance between oral flora and SSI was fair to moderate (κ index of 0.25), but detailed analysis shows a higher concordance for known and opportunistic pathogens, such as Pseudomonas aeruginosa and Enterococcus faecalis, compared to typical oral commensals. Antibiotic susceptibility tests show rapid and significant increases in resistance to clindamycin, indicating a need for a more effective alternative. Predicting pathogens in SSI using preoperative oral swabs did not demonstrate a good concordance in general for patients undergoing clean-contaminated head and neck surgery, although concordance for certain pathogenic species seem to be higher than for typical intraoral commensals. The rapid development of resistance to clindamycin precludes its use as a prophylactic agent.

  7. Distance correlation methods for discovering associations in large astrophysical databases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu

    2014-01-20

    High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less

  8. Clustering Coefficients for Correlation Networks.

    PubMed

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.

  9. Clustering Coefficients for Correlation Networks

    PubMed Central

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714

  10. [Correlation coefficient-based classification method of hydrological dependence variability: With auto-regression model as example].

    PubMed

    Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi

    2018-04-01

    Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.

  11. Assessing the Readability of Medical Documents: A Ranking Approach.

    PubMed

    Zheng, Jiaping; Yu, Hong

    2018-03-23

    The use of electronic health record (EHR) systems with patient engagement capabilities, including viewing, downloading, and transmitting health information, has recently grown tremendously. However, using these resources to engage patients in managing their own health remains challenging due to the complex and technical nature of the EHR narratives. Our objective was to develop a machine learning-based system to assess readability levels of complex documents such as EHR notes. We collected difficulty ratings of EHR notes and Wikipedia articles using crowdsourcing from 90 readers. We built a supervised model to assess readability based on relative orders of text difficulty using both surface text features and word embeddings. We evaluated system performance using the Kendall coefficient of concordance against human ratings. Our system achieved significantly higher concordance (.734) with human annotators than did a baseline using the Flesch-Kincaid Grade Level, a widely adopted readability formula (.531). The improvement was also consistent across different disease topics. This method's concordance with an individual human user's ratings was also higher than the concordance between different human annotators (.658). We explored methods to automatically assess the readability levels of clinical narratives. Our ranking-based system using simple textual features and easy-to-learn word embeddings outperformed a widely used readability formula. Our ranking-based method can predict relative difficulties of medical documents. It is not constrained to a predefined set of readability levels, a common design in many machine learning-based systems. Furthermore, the feature set does not rely on complex processing of the documents. One potential application of our readability ranking is personalization, allowing patients to better accommodate their own background knowledge. ©Jiaping Zheng, Hong Yu. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 23.03.2018.

  12. Estimation of the biserial correlation and its sampling variance for use in meta-analysis.

    PubMed

    Jacobs, Perke; Viechtbauer, Wolfgang

    2017-06-01

    Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Reliability and validity of the self-report version of the apathy evaluation scale in first-episode Psychosis: Concordance with the clinical version at baseline and 12 months follow-up.

    PubMed

    Faerden, Ann; Lyngstad, Siv Hege; Simonsen, Carmen; Ringen, Petter Andreas; Papsuev, Oleg; Dieset, Ingrid; Andreassen, Ole A; Agartz, Ingrid; Marder, Stephen R; Melle, Ingrid

    2018-05-31

    Negative symptoms have traditionally been assessed based on clinicians' observations. The subjective experience of negative symptoms in people with psychosis may bring new insight. The Apathy Evaluation Scale (AES) is commonly used to study apathy in psychosis and has corresponding self-rated (AES-S) and clinician-rated (AES-C) versions. The aim of the present study was to determine the validity and reliability of the AES-S by investigating its concordance with the AES-C. Eighty-four first-episode (FEP) patients completed the shortened 12-item AES-S and AES-C at baseline (T1) and 12 months (T2). Concordance was studied by degree of correlation, comparison of mean scores, and change and difference between diagnostic groups. The Positive and Negative Symptom Scale (PANSS) was used to study convergent and discriminative properties. High concordance was found between AES-S and AES-C at both T1 and T2 regarding mean values, change from T1 to T2, and the proportion with high levels of apathy. Both versions indicated high levels of apathy in FEP, while associations with PANSS negative symptoms were weaker for AES-S than AES-C. Controlling for depression did not significantly alter results. We concluded that self-rated apathy in FEP patients is in concordance with clinician ratings, but in need of further study. Copyright © 2018. Published by Elsevier B.V.

  14. Correlates of unmet need for contraception in Bangladesh: does couples' concordance in household decision making matter?

    PubMed

    Uddin, Jalal; Pulok, Mohammad Habibullah; Sabah, Md Nasim-Us

    2016-07-01

    A large body of literature has highlighted that women's household decision-making power is associated with better reproductive health outcomes, while most of the studies tend to measure such power from only women's point of view. Using both husband's and wife's matched responses to decision-making questions, this study examined the association between couples' concordant and discordant decision makings, and wife's unmet need for contraception in Bangladesh. This study used couple's data set (n=3336) from Bangladesh Demographic and Health Survey of 2007. Multivariate logistic regression was used to examine the likelihood of unmet need for contraception among married women of reproductive age. Study results suggested that couples who support the equalitarian power structure seemed to be more powerful in meeting the unmet demand for contraception. Logistic regression analysis revealed that compared to couple's concordant joint decision making, concordance in husband-only or other's involvement in decision making was associated with higher odds of unmet need for contraception. Wives exposed to family planning information discussed family planning more often with husbands, and those from richest households were less likely to have unmet need for contraception. Couple's concordant joint decision making, reflecting the concept of equalitarian power structure, appeared to be a significant analytic category. Policy makers in the field of family planning may promote community-based outreach programs and communication campaigns for family planning focusing on egalitarian gender roles in the household. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Estimation of the simple correlation coefficient.

    PubMed

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  16. Determination of HER2 amplification in primary breast cancer using dual-colour chromogenic in situ hybridization is comparable to fluorescence in situ hybridization: a European multicentre study involving 168 specimens.

    PubMed

    García-Caballero, Tomás; Grabau, Dorthe; Green, Andrew R; Gregory, John; Schad, Arno; Kohlwes, Elke; Ellis, Ian O; Watts, Sarah; Mollerup, Jens

    2010-03-01

    Fluorescence in situ hybridization (FISH) can be used to reveal several genomic imbalances relevant to proper cancer diagnosis and to the correct treatment regime. However, FISH requires expensive and advanced fluorescence microscopes in addition to expertise in fluorescence microscopy. To determine whether a newly developed dual-colour chromogenic in situ hybridization (CISH) method is a suitable alternative to FISH, we analysed the human epidermal growth factor receptor 2 gene (HER2) amplification level of 168 breast cancer specimens using dual-colour CISH and FISH and compared the results. We found 100% agreement between HER2 status determined by FISH and dual-colour CISH. Furthermore, we observed that the time used to score slides was significantly reduced by 28% in dual-colour CISH compared with the FISH protocol. Concordance between HER2 protein status and dual-colour CISH or FISH was equally good with an overall agreement of 96.8%. Correlation between the HER2/centromere 17 gene ratios obtained with dual-colour CISH and FISH was highly significant with an overall correlation coefficient (rho) of 0.96. We conclude that dual-colour CISH and bright field microscopy are excellent alternatives to FISH when analysing the HER2 status of primary breast cancer.

  17. Validation Study of the Body Adiposity Index as a Predictor of Percent Body Fat in Older Individuals: Findings From the BLSA

    PubMed Central

    Chang, Hui; Simonsick, Eleanor M.; Ferrucci, Luigi

    2014-01-01

    A new body adiposity index (BAI = (hip circumference)/((height)1.5) − 18) has been developed and validated in adult populations. We aimed to assess the validity of BAI in an older population. We compared the concordance correlation coefficient between BAI, body mass index (BMI), and percent body fat (fat%; by dual-energy X-ray absorptiometry) in an older population (n = 954) participating in the Baltimore Longitudinal Study of Aging. BAI was more strongly correlated with fat% than BMI (r of .7 vs .6 for BAI vs BMI and fat%, respectively, p < .01) and exhibited a smaller mean difference from fat% (−5.2 vs −7.6 for BAI vs BMI and fat%, respectively, p < .01) indicating better agreement. In men, however, BMI was in better agreement with fat% (r of .6 vs .7 for BAI vs BMI and fat%, respectively, p < .01) with a smaller mean difference from fat% (−3.0 vs −2.2 for BAI vs BMI and fat%, respectively, p < .01). Finally, BAI did not accurately predict fat% in people with a fat% below 15%. BAI provides valid estimation of body adiposity in an older adult population; however, BMI may be a better index for older men. Finally, BAI is not accurate in people with extremely low or high body fat percentages. PMID:24158764

  18. Anaerobic Threshold by Mathematical Model in Healthy and Post-Myocardial Infarction Men.

    PubMed

    Novais, L D; Silva, E; Simões, R P; Sakabe, D I; Martins, L E B; Oliveira, L; Diniz, C A R; Gallo, L; Catai, A M

    2016-02-01

    The aim of this study was to determine the anaerobic threshold (AT) in a population of healthy and post-myocardial infarction men by applying Hinkley's mathematical method and comparing its performance to the ventilatory visual method. This mathematical model, in lieu of observer-dependent visual determination, can produce more reliable results due to the uniformity of the procedure. 17 middle-aged men (55±3 years) were studied in 2 groups: 9 healthy men (54±2 years); and 8 men with previous myocardial infarction (57±3 years). All subjects underwent an incremental ramp exercise test until physical exhaustion. Breath-by-breath ventilatory variables, heart rate (HR), and vastus lateralis surface electromyography (sEMG) signal were collected throughout the test. Carbon dioxide output (V˙CO2), HR, and sEMG were studied, and the AT determination methods were compared using correlation coefficients and Bland-Altman plots. Parametric statistical tests were applied with significance level set at 5%. No significant differences were found in the HR, sEMG, and ventilatory variables at AT between the different methods, such as the intensity of effort relative to AT. Moreover, important concordance and significant correlations were observed between the methods. We concluded that the mathematical model was suitable for detecting the AT in both healthy and myocardial infarction subjects. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis.

    PubMed

    Mai, Hang-Nga; Lee, Kyeong Eun; Lee, Kyu-Bok; Jeong, Seung-Mi; Lee, Seok-Jae; Lee, Cheong-Hee; An, Seo-Young; Lee, Du-Hyeong

    2017-10-01

    The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

  20. Validity and Reliability of Perinatal Biomarkers after Storage as Dry Blood Spots on Paper

    PubMed Central

    Mihalopoulos, Nicole L.; Phillips, Terry M.; Slater, Hillarie; Thomson, J. Anne; Varner, Michael W.; Moyer-Mileur, Laurie J.

    2013-01-01

    Ojective To validate use of chip-based immunoaffinity capillary electrophoresis on dry blood spot samples (DBSS) to measure obesity-related cytokines. Methods Chip-based immunoaffinity capillary electrophoresis was used to measure adiponectin, leptin and insulin in serum and DBSS in pregnant women, cord blood, and infant heelstick at birth and 6 weeks. Concordance of measurements was determined with Pearson's correlation. Results We report high concordance between results obtained from serum and DBSS with the exception of cord blood specimens. Conclusions Ease of sample collection and storage makes DBSS an optimal method for use in studies involving neonates and young children. PMID:21735507

  1. The Attenuation of Correlation Coefficients: A Statistical Literacy Issue

    ERIC Educational Resources Information Center

    Trafimow, David

    2016-01-01

    Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.

  2. Can Measurement of Progesterone, Estradiol, and Prolactin by Immunoassay be Interchanged? A Comparison of the Roche Cobas e601 vs. Abbott Architect i2000sr.

    PubMed

    Yin, Lianli; Chen, Xiang; Tang, Yinghua; Sun, Yifan

    2017-03-01

    Progesterone is a reliable indicator of either natural or induced ovulation, and it plays an important role in preparing for implantation in the uterus and maintaining pregnancy. Estradiol is the most powerful natural estrogen in humans. It adjusts reproductive function in females and, with progesterone, maintains a pregnancy. Prolactin is also an important indicator, and its major physiological action is the initiation and maintenance of lactation in women. Architect i2000sr and Cobas e601 are automated immunoassay systems that are widely used to measure progesterone, estradiol, and prolactin concentrations in the blood. However, there is a dearth of confidence in these methods for comparative research. Therefore, the aim of this study is to investigate the correlation of serum progesterone, estradiol, and prolactin results measured with Architect i2000sr and Cobas e601. Two hundred venous blood samples from routine serum progesterone, estradiol, and prolactin tests were analyzed on the Cobas e601 and the Architect i2000sr in our laboratory within the same day. Passing-Bablok regression analysis and a Bland-Altman plot were used to compare methods. According to the concordance correlation coefficient, the correlation was strong in estradiol, but the correlation of prolactin and progesterone was poor between the two systems. The Bland-Altman plots showed that the measured value of progesterone, estradiol, and prolactin detected by Cobas e601 were about 1.30, 1.24, and 1.10 times higher, respectively, than that measured using Architect i2000sr. The results of progesterone, estradiol, and prolactin of one method should not be directly transferable to the other.

  3. Prevalence and clinical correlates of metabolic syndrome in Nigerians living with human immunodeficiency virus/acquired immunodeficiency syndrome.

    PubMed

    Ayodele, Olugbenga Edward; Akinboro, Adeolu Oludayo; Akinyemi, Suliat Omolola; Adepeju, Akinlawon Adetiloye; Akinremi, Oluwaseun Akinsanmi; Alao, Christiana Adeola; Popoola, Adetoun Adedayo

    2012-10-01

    Sub-Saharan Africa bears an inordinate burden of human immunodeficiency virus (HIV) infection/acquired immune deficiency syndrome (AIDS). Reports have shown increased prevalence of clustering of cardiovascular risk factors referred to as metabolic syndrome in treatment-naïve patients and patients on highly active antiretroviral therapy (HAART). In view of the fact that metabolic syndrome is a heterogeneous disorder with substantial variability in the prevalence and component traits within and across populations and the dearth of publications on the prevalence and clinical correlates of metabolic syndrome in people living with HIV/AIDS (PLWHA) in Nigeria, this study was carried out to determine the prevalence and clinical correlates of metabolic syndrome among an HIV-infected outpatient population using the National Cholesterol Education Adult Treatment Panel III (NCEP ATP III), the International Diabetes Federation (IDF), and the Joint Interim Statement (JIS) definitions. We also sought to determine if HAART use and CD4 count level were associated with metabolic syndrome. This cross-sectional study involved 291 (95 men, 196 women) consecutive PLWHA. Anthropometry, blood pressure, fasting plasma glucose, and lipid profile values were determined. The prevalence rates of metabolic syndrome according to the ATP III, IDF, and JIS criteria were 12.7%, 17.2%, and 21.0%, respectively. Metabolic syndrome was significantly associated with female gender (all definitions), body mass index (all definitions), increasing age, and CD4 count (IDF definition). There was no significant association between metabolic syndrome and HAART. The concordance [kappa coefficient (κ)] between the definitions of metabolic syndrome varied between 0.583 and 0.878. The prevalence of metabolic syndrome varied with the criteria used and metabolic syndrome correlates with traditional cardiovascular risk factors rather than HAART-related factors.

  4. Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers.

    PubMed

    Blois, Shauna L; Banerjee, Amrita; Wood, R Darren; Park, Fiona M

    2013-07-01

    The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer's guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy.

  5. Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers

    PubMed Central

    Blois, Shauna L.; Banerjee, Amrita; Wood, R. Darren; Park, Fiona M.

    2013-01-01

    The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer’s guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy. PMID:24101802

  6. Analysis of codon usage in beta-tubulin sequences of helminths.

    PubMed

    von Samson-Himmelstjerna, G; Harder, A; Failing, K; Pape, M; Schnieder, T

    2003-07-01

    Codon usage bias has been shown to be correlated with gene expression levels in many organisms, including the nematode Caenorhabditis elegans. Here, the codon usage (cu) characteristics for a set of currently available beta-tubulin coding sequences of helminths were assessed by calculating several indices, including the effective codon number (Nc), the intrinsic codon deviation index (ICDI), the P2 value and the mutational response index (MRI). The P2 value gives a measure of translational pressure, which has been shown to be correlated to high gene expression levels in some organisms, but it has not yet been analysed in that respect in helminths. For all but two of the C. elegans beta-tubulin coding sequences investigated, the P2 value was the only index that indicated the presence of codon usage bias. Therefore, we propose that in general the helminth beta-tubulin sequences investigated here are not expressed at high levels. Furthermore, we calculated the correlation coefficients for the cu patterns of the helminth beta-tubulin sequences compared with those of highly expressed genes in organisms such as Escherichia coli and C. elegans. It was found that beta-tubulin cu patterns for all sequences of members of the Strongylida were significantly correlated to those for highly expressed C. elegans genes. This approach provides a new measure for comparing the adaptation of cu of a particular coding sequence with that of highly expressed genes in possible expression systems.Finally, using the cu patterns of the sequences studied, a phylogenetic tree was constructed. The topology of this tree was very much in concordance with that of a phylogeny based on small subunit ribosomal DNA sequence alignments.

  7. Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA).

    PubMed

    Pineau, V; Lebel, B; Gouzy, S; Dutheil, J-J; Vielpeau, C

    2010-10-01

    The use of dual mobility cups is an effective method to prevent dislocations. However, the specific design of these implants can raise the suspicion of increased wear and subsequent periprosthetic osteolysis. Using radiostereometric analysis (RSA), migration of the femoral head inside the cup of a dual mobility implant can be defined to apprehend polyethylene wear rate. The study aimed to establish the precision of RSA measurement of femoral head migration in the cup of a dual mobility implant, and its intra- and interobserver variability. A total hip prosthesis phantom was implanted and placed under weight loading conditions in a simulator. Model-based RSA measurement of implant penetration involved specially machined polyethylene liners with increasing concentric wear (no wear, then 0.25, 0.5 and 0.75mm). Three examiners, blinded to the level of wear, analyzed (10 times) the radiostereometric films of the four liners. There was one experienced, one trained, and one inexperienced examiner. Statistical analysis measured the accuracy, precision, and intra- and interobserver variability by calculating Root Mean Square Error (RMSE), Concordance Correlation Coefficient (CCC), Intra Class correlation Coefficient (ICC), and Bland-Altman plots. Our protocol, that used a simple geometric model rather than the manufacturer's CAD files, showed precision of 0.072mm and accuracy of 0.034mm, comparable with machining tolerances with low variability. Correlation between wear measurement and true value was excellent with a CCC of 0.9772. Intraobserver reproducibility was very good with an ICC of 0.9856, 0.9883 and 0.9842, respectively for examiners 1, 2 and 3. Interobserver reproducibility was excellent with a CCC of 0.9818 between examiners 2 and 1, and 0.9713 between examiners 3 and 1. Quantification of wear is indispensable for the surveillance of dual mobility implants. This in vitro study validates our measurement method. Our results, and comparison with other studies using different measurement technologies (RSA, standard radiographs, Martell method) make model-based RSA the reference method for measuring the wear of total hip prostheses in vivo. Level 3. Prospective diagnostic study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  8. Determination of IgE antibodies to the benzylpenicilloyl determinant: a comparison of the sensitivity and specificity of three radio allergo sorbent test methods.

    PubMed

    Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E

    1997-01-01

    The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.

  9. 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - our experience in 16 cases.

    PubMed

    Aboul-Hosn Centenero, Samir; Hernández-Alfaro, Federico

    2012-02-01

    The aim of this article is to determine the advantages of 3D planning in predicting postoperative results and manufacturing surgical splints using CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) technology in orthognathic surgery when the software program Simplant OMS 10.1 (Materialise(®), Leuven, Belgium) was used for the purpose of this study which was carried out on 16 patients. A conventional preoperative treatment plan was devised for each patient following our Centre's standard protocol, and surgical splints were manufactured. These splints were used as study controls. The preoperative treatment plans devised were then transferred to a 3D-virtual environment on a personal computer (PC). Surgery was simulated, the prediction of results on soft and hard tissue produced, and surgical splints manufactured using CAD/CAM technology. In the operating room, both types of surgical splints were compared and the degree of similitude in results obtained in three planes was calculated. The maxillary osteotomy line was taken as the point of reference. The level of concordance was used to compare the surgical splints. Three months after surgery a second set of 3D images were obtained and used to obtain linear and angular measurements on screen. Using the Intraclass Correlation Coefficient these postoperative measurements were compared with the measurements obtained when predicting postoperative results. Results showed that a high degree of correlation in 15 of the 16 cases. A high coefficient of correlation was obtained in the majority of predictions of results in hard tissue, although less precise results were obtained in measurements in soft tissue in the labial area. The study shows that the software program used in the study is reliable for 3D planning and for the manufacture of surgical splints using CAD/CAM technology. Nevertheless, further progress in the development of technologies for the acquisition of 3D images, new versions of software programs, and further studies of objective data are necessary to increase precision in computerised 3D planning. Copyright © 2011 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Fatty acid profile of plasma NEFA does not reflect adipose tissue fatty acid profile.

    PubMed

    Walker, Celia G; Browning, Lucy M; Stecher, Lynne; West, Annette L; Madden, Jackie; Jebb, Susan A; Calder, Philip C

    2015-09-14

    Adipose tissue (AT) fatty acid (FA) composition partly reflects habitual dietary intake. Circulating NEFA are mobilised from AT and might act as a minimally invasive surrogate marker of AT FA profile. Agreement between twenty-eight FA in AT and plasma NEFA was assessed using concordance coefficients in 204 male and female participants in a 12-month intervention using supplements to increase the intake of EPA and DHA. Concordance coefficients generally showed very poor agreement between AT FA and plasma NEFA at baseline SFA: 0·07; MUFA: 0·03; n-6 PUFA: 0·28; n-3 PUFA: 0·01). Participants were randomly divided into training (70 %) and validation (30 %) data sets, and models to predict AT and dietary FA were fitted using data from the training set, and their predictive ability was assessed using data from the validation set. AT n-6 PUFA and SFA were predicted from plasma NEFA with moderate accuracy (mean absolute percentage error n-6 PUFA: 11 % and SFA: 8 %), but predicted values were unable to distinguish between low, medium and high FA values, with only 25 % of n-6 PUFA and 33 % of SFA predicted values correctly assigned to the appropriate tertile group. Despite an association between AT and plasma NEFA EPA (P=0·001) and DHA (P=0·01) at baseline, there was no association after the intervention. To conclude, plasma NEFA are not a suitable surrogate for AT FA.

  11. Identification of Correlated GRACE Monthly Harmonic Coefficients Using Pattern Recognition and Neural Networks

    NASA Astrophysics Data System (ADS)

    Piretzidis, D.; Sra, G.; Sideris, M. G.

    2016-12-01

    This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).

  12. Performance evaluation of LUMIPULSE G1200 autoimmunoanalyzer for the detection of serum hepatitis B virus markers.

    PubMed

    Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk

    2013-05-01

    We evaluated recently introduced automated immunoassay analyzer LUMIPULSE G1200 (Fujirebio, Inc., Tokyo, Japan) for detecting serologic hepatitis B virus (HBV) markers by comparison with the results by ARCHITECT i4000SR (Abbott, Abbott Park, IL). Precision performance was evaluated over 20 days. HBV surface antigen (HBsAg), HBV e antigen (HBeAg), antibodies to HBV core antigen (anti-HBc), antibodies to HBeAg (anti-HBe), and antibodies to HBsAg (anti-HBs) in a total of 1,000 serum samples were assessed by the two analyzers. Discrepant results were retested by COBAS e411 (Roche Diagnostics, Mannheim, Germany). LUMIPULSE showed excellent precision performance of total imprecision less than 3.5% coefficient of variation. The qualitative results between the two analyzers were agreed with each other in 92.0-99.8% of the specimens according to the different HBV markers. The degrees of reactions for HBeAg were moderately correlated between the two analyzers (r = 0.60), and those of other HBV markers were well correlated (r = 0.80 or greater). However, there were 183 discrepancies among 1,000 cases, and most of them showed degree of reaction around the cutoff values. LUMIPULSE G1200 showed well-concordant results with ARCITHECT for hepatitis B serologic tests. However, results near the cutoff values would need to be retested with other immunoassay or molecular methods, when the serological profiles of HBV markers are unusual or are not correlated to the clinical conditions of the patient, due to discrepancies between the immunoassay analyzers. © 2013 Wiley Periodicals, Inc.

  13. Measurement Differences Between Two Immunoassay Systems for LH and FSH: A Comparison of Roche Cobas e601 vs. Abbott Architect i2000sr.

    PubMed

    Yin, Lianli; Tang, Yinghua; Chen, Xiang; Sun, Yifan

    2018-03-01

    Follicle-stimulating hormone (FSH) and luteinizing hormone (LH) regulate the growth and reproductive activity of gonadal tissue and determine the concentration of LH is essential for the prediction of ovulation. Collectively, FSH and LH are important measurements to ascertain the causes of infertility as well as diagnosing disorders such as polycystic ovary syndrome and pituitary and gonadal dysfunction. This study compares the correlation between LH and FSH measurements during examination with two different systems, Architect i2000sr (Abbott Laboratories; Lake Bluff, IL, USA) and Cobas e601 (Roche; Geneva, Switzerland), and assesses the differences between these systems. Serum analysis was performed for 95 patients using both the Cobas e601 and Architect i2000sr systems. The method used to compare the systems was Passing-Bablok regression analysis with a Bland-Altman agreement plot. Inter-rater agreement was analyzed using a concordance correlation coefficient. Architect i2000sr and Cobas e601 have strong correlations in their LH and FSH results. However, the Bland-Altman plot shows that LH and FSH measurements in Cobas e601 are about 1.31 times and 1.26 times higher than those in Architect i2000sr, respectively. Passing-Bablok regression analysis also shows significant proportional deviation between them. The difference between the test results for LH and FSH in Cobas e601 and Architect i2000sr indicate that the results from one system cannot be directly used to evaluate the other system.

  14. Agreement between Internet-based self- and proxy-reported health care resource utilization and administrative health care claims.

    PubMed

    Palmer, Liisa; Johnston, Stephen S; Rousculp, Matthew D; Chu, Bong-Chul; Nichol, Kristin L; Mahadevia, Parthiv J

    2012-05-01

    Although Internet-based surveys are becoming more common, little is known about agreement between administrative claims data and Internet-based survey self- and proxy-reported health care resource utilization (HCRU) data. This analysis evaluated the level of agreement between self- and proxy-reported HCRU data, as recorded through an Internet-based survey, and administrative claims-based HCRU data. The Child and Household Influenza-Illness and Employee Function study collected self- and proxy-reported HCRU data monthly between November 2007 and May 2008. Data included the occurrence and number of visits to hospitals, emergency departments, urgent care centers, and outpatient offices for a respondent's and his or her household members' care. Administrative claims data from the MarketScan® Databases were assessed during the same time and evaluated relative to survey-based metrics. Only data for individuals with employer-sponsored health care coverage linkable to claims were included. The Kappa (κ) statistic was used to evaluate visit concordance, and the intraclass correlation coefficient was used to describe frequency consistency. Agreement for presence of a health care visit and the number of visits were similar for self- and proxy-reported HCRU data. There was moderate to substantial agreement related to health care visit occurrence between survey-based and claims-based HCRU data for inpatient, emergency department, and office visits (κ: 0.47-0.77). There was less agreement on health care visit frequencies, with intraclass correlation coefficient values ranging from 0.14 to 0.71. This study's agreement values suggest that Internet-based surveys are an effective method to collect self- and proxy-reported HCRU data. These results should increase confidence in the use of the Internet for evaluating disease burden. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. Relationship between the percentage of body fat and surrogate indices of fatness in male and female Polish active and sedentary students.

    PubMed

    Lutoslawska, Grażyna; Malara, Marzena; Tomaszewski, Paweł; Mazurek, Krzysztof; Czajkowska, Anna; Kęska, Anna; Tkaczyk, Joanna

    2014-05-13

    Limited data have indicated that body mass index (BMI), waist circumference (WC), waist to hip ratio (WHR) and waist to height ratio (WHtR) of athletes and young adults provide misleading results concerning body fat content. This study was aimed at the evaluation of the relationship between different surrogate indices of fatness (BMI, WC, WHR, WHtR and body adiposity index (BAI)) with the percentage of body fat in Polish students with respect to their sex and physical activity. A total of 272 students volunteered to participate in the study. Of these students, 177 physical education students (90 males and 87 females) were accepted as active (physical activity of 7 to 9 hours/week); and 95 students of other specializations (49 males and 46 females) were accepted as sedentary (physical activity of 1.5 hours/week). Weight, height, waist and hip circumferences were measured, and BMI, WHR, WHtR and BAI were calculated. Body fat percentage was assessed using four skinfold measurements. Classification of fatness according to the BMI and the percentage of body fat have indicated that BMI overestimates fatness in lean subjects (active men and women, sedentary men), but underestimates body fat in obese subjects (sedentary women). In all groups, BMI, WHR, WHtR and BAI were significantly correlated with the percentage of body fat (with the exception of WHR and hip circumference in active and sedentary women, respectively). However, coefficients of determination not exceeding 50% and Lin's concordance correlation coefficients lower than 0.9 indicated no relationship between measured and calculated body fat. The findings in the present study support the concept that irrespective of physical activity and sex none of the calculated indices of fatness are useful in the determination of body fat in young adults. Thus, it seems that easily calculated indices may contribute to distorted body image and unhealthy dietary habits observed in many young adults in Western countries, but also in female athletes.

  16. Validation of the portable Air-Smart Spirometer

    PubMed Central

    Núñez Fernández, Marta; Pallares Sanmartín, Abel; Mouronte Roibas, Cecilia; Cerdeira Domínguez, Luz; Botana Rial, Maria Isabel; Blanco Cid, Nagore; Fernández Villar, Alberto

    2018-01-01

    Background The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet. Methods In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air Smart-Spirometer device and a conventional spirometer, and analyze the ability of this new portable device to detect obstructions. Patients were included for 2 consecutive months. We calculate sensitivity, specificity, positive and negative predictive value (PPV and NPV) and likelihood ratio (LR +, LR-) as well as the Kappa Index to evaluate the concordance between the two devices for the detection of obstruction. The agreement and relation between the values of FEV1 and FVC in absolute value and the FEV1/FVC ratio measured by both devices were analyzed by calculating the intraclass correlation coefficient (ICC) and the Pearson correlation coefficient (r) respectively. Results 200 patients (100 from each center) were included with a mean age of 57 (± 14) years, 110 were men (55%). Obstruction was detected by conventional spirometry in 73 patients (40.1%). Using a FEV1/FVC ratio smaller than 0.7 to detect obstruction with the Air Smart-Spirometer, the kappa index was 0.88, sensitivity (90.4%), specificity (97.2%), PPV (95.7%), NPV (93.7%), positive likelihood ratio (32.29), and negative likelihood ratio (0.10). The ICC and r between FEV1, FVC, and FEV1 / FVC ratio measured by the Air Smart Spirometer and the conventional spirometer were all higher than 0.94. Conclusion The Air-Smart Spirometer is a simple and very precise instrument for detecting obstructive airway diseases. It is easy to use, which could make it especially useful non-specialized care and in other areas. PMID:29474502

  17. Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin G concentration and an analysis of the effect of signalment on levels in canine serum.

    PubMed

    Seigneur, A; Hou, S; Shaw, R A; McClure, Jt; Gelens, H; Riley, C B

    2015-01-15

    Deficiency in immunoglobulin G (IgG) is associated with an increased susceptibility to infections in humans and animals, and changes in IgG levels occur in many disease states. In companion animals, failure of transfer of passive immunity is uncommonly diagnosed but mortality rates in puppies are high and more than 30% of these deaths are secondary to septicemia. Currently, radial immunodiffusion (RID) and enzyme-linked immunosorbent assays are the most commonly used methods for quantitative measurement of IgG in dogs. In this study, a Fourier-transform infrared spectroscopy (FTIR) assay for canine serum IgG was developed and compared to the RID assay as the reference standard. Basic signalment data and health status of the dogs were also analyzed to determine if they correlated with serum IgG concentrations based on RID results. Serum samples were collected from 207 dogs during routine hematological evaluation, and IgG concentrations determined by RID. The FTIR assay was developed using partial least squares regression analysis and its performance evaluated using RID assay as the reference test. The concordance correlation coefficient was 0.91 for the calibration model data set and 0.85 for the prediction set. A Bland-Altman plot showed a mean difference of -89 mg/dL and no systematic bias. The modified mean coefficient of variation (CV) for RID was 6.67%, and for FTIR was 18.76%. The mean serum IgG concentration using RID was 1943 ± 880 mg/dL based on the 193 dogs with complete signalment and health data. When age class, gender, breed size and disease status were analyzed by multivariable ANOVA, dogs < 2 years of age (p = 0.0004) and those classified as diseased (p = 0.03) were found to have significantly lower IgG concentrations than older and healthy dogs, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Intraoral radiographs texture analysis for dental implant planning.

    PubMed

    Mundim, Mayara B V; Dias, Danilo R; Costa, Ronaldo M; Leles, Cláudio R; Azevedo-Marques, Paulo M; Ribeiro-Rotta, Rejane F

    2016-11-01

    Computer vision extracts features or attributes from images improving diagnosis accuracy and aiding in clinical decisions. This study aims to investigate the feasibility of using texture analysis of periapical radiograph images as a tool for dental implant treatment planning. Periapical radiograph images of 127 jawbone sites were obtained before and after implant placement. From the superimposition of the pre- and post-implant images, four regions of interest (ROI) were delineated on the pre-implant images for each implant site: mesial, distal and apical peri-implant areas and a central area. Each ROI was analysed using Matlab® software and seven image attributes were extracted: mean grey level (MGL), standard deviation of grey levels (SDGL), coefficient of variation (CV), entropy (En), contrast, correlation (Cor) and angular second moment (ASM). Images were grouped by bone types-Lekholm and Zarb classification (1,2,3,4). Peak insertion torque (PIT) and resonance frequency analysis (RFA) were recorded during implant placement. Differences among groups were tested for each image attribute. Agreement between measurements of the peri-implant ROIs and overall ROI (peri-implant + central area) was tested, as well as the association between primary stability measures (PIT and RFA) and texture attributes. Differences among bone type groups were found for MGL (p = 0.035), SDGL (p = 0.024), CV (p < 0.001) and En (p < 0.001). The apical ROI showed a significant difference from the other regions for all attributes, except Cor. Concordance correlation coefficients were all almost perfect (ρ > 0.93), except for ASM (ρ = 0.62). Texture attributes were significantly associated with the implant stability measures. Texture analysis of periapical radiographs may be a reliable non-invasive quantitative method for the assessment of jawbone and prediction of implant stability, with potential clinical applications. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Bioimpedance analysis vs. DEXA as a screening tool for osteosarcopenia in lean, overweight and obese Caucasian postmenopausal females.

    PubMed

    Peppa, Melpomeni; Stefanaki, Charikleia; Papaefstathiou, Athanasios; Boschiero, Dario; Dimitriadis, George; Chrousos, George P

    2017-04-01

    We aimed at evaluating the efficiency of a newly developed, advanced Bioimpedance Analysis (BIA-ACC®) device as a screening tool for determining the degree of obesity and osteosarcopenia in postmenopausal women with normal or decreased bone density determined by Dual-Energy X-Ray absorptiometry (DEXA) in a representative sample of Greek postmenopausal women. This is a single-gate cross-sectional study of body composition measured by BIA-ACC® and DEXA. Postmenopausal females with BMI ranging from 18.5 to 40 kg/m2 were subjected to two consecutive measurements of DEXA and BIA-ACC® within 5-10 minutes of each other. We used Pearson's co-efficient to examine linear correlations, the intraclass correlation co-efficient (ICC) to test reliability, Bland-Atman plots to assess bias and Deming regressions to establish the agreement in parameters measured by BIA-ACC® and DEXA. Last, we used ANOVA, with Bonferroni correction and Dunnett T3 post hoc tests, for assessing the differences between quantitative and Pearson's x2 between qualitative variables. Our sample consisted of 84 overweight/obese postmenopausal women, aged 39-83 years, of whom 22 had normal bone density, 38 had osteopenia and 24 had osteoporosis based on DEXA measurements, using quota sampling. ICCs and Deming regressions showed strong agreement between BIA-ACC® and DEXA and demonstrated minimal proportional differences of no apparent clinical significance. Bland-Altman plots indicated minimal biases. Fat, skeletal and bone mass measured by BIA-ACC® and DEXA were increased in the non-osteopenic/non-osteoporotic women compared with those of the osteopenic and osteoporotic groups. BIA-ACC® is a rapid, bloodless and useful screening tool for determining body composition adiposity and presence of osteo-sarcopenic features in postmenopausal women. Women with osteopenia and osteoporosis evaluated by DEXA had decreased fat, skeletal and bone mass compared with normal bone density women, suggesting concordance in the change of these three organ masses in postmenopausal women.

  20. An International Ki67 Reproducibility Study

    PubMed Central

    2013-01-01

    Background In breast cancer, immunohistochemical assessment of proliferation using the marker Ki67 has potential use in both research and clinical management. However, lack of consistency across laboratories has limited Ki67’s value. A working group was assembled to devise a strategy to harmonize Ki67 analysis and increase scoring concordance. Toward that goal, we conducted a Ki67 reproducibility study. Methods Eight laboratories received 100 breast cancer cases arranged into 1-mm core tissue microarrays—one set stained by the participating laboratory and one set stained by the central laboratory, both using antibody MIB-1. Each laboratory scored Ki67 as percentage of positively stained invasive tumor cells using its own method. Six laboratories repeated scoring of 50 locally stained cases on 3 different days. Sources of variation were analyzed using random effects models with log2-transformed measurements. Reproducibility was quantified by intraclass correlation coefficient (ICC), and the approximate two-sided 95% confidence intervals (CIs) for the true intraclass correlation coefficients in these experiments were provided. Results Intralaboratory reproducibility was high (ICC = 0.94; 95% CI = 0.93 to 0.97). Interlaboratory reproducibility was only moderate (central staining: ICC = 0.71, 95% CI = 0.47 to 0.78; local staining: ICC = 0.59, 95% CI = 0.37 to 0.68). Geometric mean of Ki67 values for each laboratory across the 100 cases ranged 7.1% to 23.9% with central staining and 6.1% to 30.1% with local staining. Factors contributing to interlaboratory discordance included tumor region selection, counting method, and subjective assessment of staining positivity. Formal counting methods gave more consistent results than visual estimation. Conclusions Substantial variability in Ki67 scoring was observed among some of the world’s most experienced laboratories. Ki67 values and cutoffs for clinical decision-making cannot be transferred between laboratories without standardizing scoring methodology because analytical validity is limited. PMID:24203987

  1. Bronchiolitis Score of Sant Joan de Déu: BROSJOD Score, validation and usefulness.

    PubMed

    Balaguer, Mònica; Alejandre, Carme; Vila, David; Esteban, Elisabeth; Carrasco, Josep L; Cambra, Francisco José; Jordan, Iolanda

    2017-04-01

    To validate the bronchiolitis score of Sant Joan de Déu (BROSJOD) and to examine the previously defined scoring cutoff. Prospective, observational study. BROSJOD scoring was done by two independent physicians (at admission, 24 and 48 hr). Internal consistency of the score was assessed using Cronbach's α. To determine inter-rater reliability, the concordance correlation coefficient estimated as an intraclass correlation coefficient (CCC) and limits of agreement estimated as the 90% total deviation index (TDI) were estimated. An expert opinion was used to classify patients according to clinical severity. A validity analysis was conducted comparing the 3-level classification score to that expert opinion. Volume under the surface (VUS), predictive values, and probability of correct classification (PCC) were measured to assess discriminant validity. About 112 patients were recruited, 62 of them (55.4%) males. Median age: 52.5 days (IQR: 32.75-115.25). The admission Cronbach's α was 0.77 (CI95%: 0.71; 0.82) and at 24 hr it was 0.65 (CI95%: 0.48; 0.7). The inter-rater reliability analysis was: CCC at admission 0.96 (95%CI 0.94-0.97), at 24 h 0.77 (95%CI 0.65-0.86), and at 48 hr 0.94 (95%CI 0.94-0.97); TDI 90%: 1.6, 2.9, and 1.57, respectively. The discriminant validity at admission: VUS of 0.8 (95%CI 0.70-0.90), at 24 h 0.92 (95%CI 0.85-0.99), and at 48 hr 0.93 (95%CI 0.87-0.99). The predictive values and PCC values were within 38-100% depending on the level of clinical severity. There is a high inter-rater reliability, showing the BROSJOD score to be reliable and valid, even when different observers apply it. Pediatr Pulmonol. 2017;52:533-539. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, P; Wang, J; Zhong, H

    Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Waveletmore » GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and prognosis prediction.« less

  3. Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.

    PubMed

    Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M

    2007-09-01

    We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.

  4. Prevalence and correlates of HIV discordance and concordance among Chinese-Burmese mixed couples in the Dehong prefecture of Yunnan province, China.

    PubMed

    Duan, Song; Ding, Yingying; Yang, Yuecheng; Lu, Lin; Sun, Jiangping; Wang, Ning; Wang, Lu; Xiang, Lifen; Jia, Manhong; Wu, Zunyou; He, Na

    2012-11-01

    Many people from Burma have migrated to Dehong prefecture and married local residents during the past decades; however, little is known about HIV risk-taking behaviours and HIV prevalence among these mixed couples. We investigated factors correlated with HIV discordance and concordance within Chinese?Burmese mixed couples in Dehong prefecture, Yunnan province, China. A cross-sectional study with face-to-face questionnaire interviews and HIV blood testing was conducted. Of 5742 couples, 1.6% couples were HIV-infected concordant, 2.2% were HIV serodiscordant with an HIV-infected male spouse and 0.9% were HIV serodiscordant with an HIV-infected female spouse. HIV discordance with an HIV-infected male spouse was significantly associated with characteristics of the male spouse, including being aged =30 years, non-Han ethnic minority, a marital relationship of <3 years, commercial sex and injection drug use by the male spouse. HIV discordance with an HIV-infected female spouse was significantly associated with an education level of primary school (v. illiterate); a marital status of being in their second marriage, widowed or divorced; a history of sexually transmissible infection diagnosis of the female spouse; noncommercial extramarital sex by the female spouse or by both spouses; and injection drug use by the male spouse. A marital relationship of =3 years was the only significant independent correlate of HIV-infected seroconcordance. The study findings underscore the importance of premarital HIV counselling and testing for this population, and the need for targeted interventions among HIV serodiscordant mixed couples to reduce secondary transmission as early as possible when the relationship begins.

  5. Five omic technologies are concordant in differentiating the biochemical characteristics of the berries of five grapevine (Vitis vinifera L.) cultivars.

    PubMed

    Ghan, Ryan; Van Sluyter, Steven C; Hochberg, Uri; Degu, Asfaw; Hopper, Daniel W; Tillet, Richard L; Schlauch, Karen A; Haynes, Paul A; Fait, Aaron; Cramer, Grant R

    2015-11-16

    Grape cultivars and wines are distinguishable by their color, flavor and aroma profiles. Omic analyses (transcripts, proteins and metabolites) are powerful tools for assessing biochemical differences in biological systems. Berry skins of red- (Cabernet Sauvignon, Merlot, Pinot Noir) and white-skinned (Chardonnay, Semillon) wine grapes were harvested near optimum maturity (°Brix-to-titratable acidity ratio) from the same experimental vineyard. The cultivars were exposed to a mild, seasonal water-deficit treatment from fruit set until harvest in 2011. Identical sample aliquots were analyzed for transcripts by grapevine whole-genome oligonucleotide microarray and RNAseq technologies, proteins by nano-liquid chromatography-mass spectroscopy, and metabolites by gas chromatography-mass spectroscopy and liquid chromatography-mass spectroscopy. Principal components analysis of each of five Omic technologies showed similar results across cultivars in all Omic datasets. Comparison of the processed data of genes mapped in RNAseq and microarray data revealed a strong Pearson's correlation (0.80). The exclusion of probesets associated with genes with potential for cross-hybridization on the microarray improved the correlation to 0.93. The overall concordance of protein with transcript data was low with a Pearson's correlation of 0.27 and 0.24 for the RNAseq and microarray data, respectively. Integration of metabolite with protein and transcript data produced an expected model of phenylpropanoid biosynthesis, which distinguished red from white grapes, yet provided detail of individual cultivar differences. The mild water deficit treatment did not significantly alter the abundance of proteins or metabolites measured in the five cultivars, but did have a small effect on gene expression. The five Omic technologies were consistent in distinguishing cultivar variation. There was high concordance between transcriptomic technologies, but generally protein abundance did not correlate well with transcript abundance. The integration of multiple high-throughput Omic datasets revealed complex biochemical variation amongst five cultivars of an ancient and economically important crop species.

  6. A New Methodology of Spatial Cross-Correlation Analysis

    PubMed Central

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120

  7. A new methodology of spatial cross-correlation analysis.

    PubMed

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.

  8. Examining Convergence of Retrospective and Ecological Momentary Assessment Measures of Negative Affect and Eating Disorder Behaviors

    PubMed Central

    Wonderlich, Joseph A.; Lavender, Jason M.; Wonderlich, Stephen A.; Peterson, Carol B.; Crow, Scott J.; Engel, Scott G.; Le Grange, Daniel; Mitchell, James E.; Crosby, Ross D.

    2017-01-01

    Objective Data gathered via retrospective forms of assessment are subject to various recall biases. Ecological momentary assessment (EMA) is an alternative approach involving repeated momentary assessments within a participant's natural environment, thus reducing recall biases and improving ecological validity. EMA has been used in numerous prior studies examining various constructs of theoretical relevance to eating disorders. Method This investigation includes data from three previously published studies with distinct clinical samples: (a) women with anorexia nervosa (N=118), (b) women with bulimia nervosa (N=133), and (c) obese men and women (N=50; 9 with current binge eating disorder). Each study assessed negative affective states and eating disorder behaviors using traditional retrospective assessments and EMA. Spearman rho correlations were used to evaluate the concordance of retrospective versus EMA measures of affective and/or behavioral constructs in each sample. Bland-Altman plots were also used to further evaluate concordance in the assessment of eating disorder behaviors. Results There was moderate to strong concordance for the measures of negative affective states across all three studies. Moderate to strong concordance was also found for the measures of binge eating and exercise frequency. The strongest evidence of concordance across measurement approaches was found for purging behaviors. Discussion Overall, these preliminary findings support the convergence of retrospective and EMA assessments of both negative affective states and various eating disorder behaviors. Given the advantages and disadvantages associated with each of these assessment approaches, the specific questions being studied in future empirical studies should inform decisions regarding selection of the most appropriate method. PMID:25195932

  9. Do End-of-Rotation and End-of-Shift Assessments Inform Clinical Competency Committees’ (CCC) Decisions?

    PubMed Central

    Regan, Linda; Cope, Leslie; Omron, Rodney; Bright, Leah; Bayram, Jamil D.

    2018-01-01

    Introduction Clinical Competency Committees (CCC) require reliable, objective data to inform decisions regarding assignment of milestone proficiency levels, which must be reported to the Accreditation Council for Graduate Medical Education. After the development of two new assessment methods, the end-of-shift (EOS) assessment and the end-of-rotation (EOR) assessment, we sought to evaluate their performance. We report data on the concordance between these assessments, as well as how each informs the final proficiency level determined in biannual CCC meetings. We hypothesized that there would be a high concordance level between the two assessment methods, including concordance of both the EOS and EOR with the final proficiency level designation by the CCC. Methods The residency program is an urban academic four-year emergency medicine residency with 48 residents. After their shifts in the emergency department (ED), residents handed out EOS assessment forms asking about individual milestones from 15 subcompetencies to supervising physicians, as well as triggered electronic EOR-doctor (EORd) assessments to supervising doctors and EOR-nurse (EORn) to nurses they had worked with after each two-week ED block. EORd assessments contained the full proficiency level scale from 16 subcompetencies, while EORn assessments contained four subcompetencies. Data reports were generated after each six-month assessment period and data was aggregated. We calculated Spearman’s rank order correlations for correlations between assessment types and between assessments and final CCC proficiency levels. Results Over 24 months, 5,234 assessments were completed. The strongest correlations with CCC proficiency levels were the EORd for the immediate six-month assessment period prior (rs 0.71–0.84), and the CCC proficiency levels from the previous six-months (rs 0.83–0.92). EOS assessments had weaker correlations (rs 0.49 to 0.62), as did EORn (rs 0.4 to 0.73). Conclusion End-of-rotation assessments completed by supervising doctors are most highly correlated with final CCC proficiency level designations, while end-of-shift assessments and end-of-rotation assessments by nurses did not correlate strongly with final CCC proficiency levels, both with overestimation of levels noted. Every level of proficiency the CCC assigned appears to be highly correlated with the designated level in the immediate six-month period, perhaps implying CCC members are biased by previous level assignments. PMID:29383066

  10. Do End-of-Rotation and End-of-Shift Assessments Inform Clinical Competency Committees' (CCC) Decisions?

    PubMed

    Regan, Linda; Cope, Leslie; Omron, Rodney; Bright, Leah; Bayram, Jamil D

    2018-01-01

    Clinical Competency Committees (CCC) require reliable, objective data to inform decisions regarding assignment of milestone proficiency levels, which must be reported to the Accreditation Council for Graduate Medical Education. After the development of two new assessment methods, the end-of-shift (EOS) assessment and the end-of-rotation (EOR) assessment, we sought to evaluate their performance. We report data on the concordance between these assessments, as well as how each informs the final proficiency level determined in biannual CCC meetings. We hypothesized that there would be a high concordance level between the two assessment methods, including concordance of both the EOS and EOR with the final proficiency level designation by the CCC. The residency program is an urban academic four-year emergency medicine residency with 48 residents. After their shifts in the emergency department (ED), residents handed out EOS assessment forms asking about individual milestones from 15 subcompetencies to supervising physicians, as well as triggered electronic EOR-doctor (EORd) assessments to supervising doctors and EOR-nurse (EORn) to nurses they had worked with after each two-week ED block. EORd assessments contained the full proficiency level scale from 16 subcompetencies, while EORn assessments contained four subcompetencies. Data reports were generated after each six-month assessment period and data was aggregated. We calculated Spearman's rank order correlations for correlations between assessment types and between assessments and final CCC proficiency levels. Over 24 months, 5,234 assessments were completed. The strongest correlations with CCC proficiency levels were the EORd for the immediate six-month assessment period prior (r s 0.71-0.84), and the CCC proficiency levels from the previous six-months (r s 0.83-0.92). EOS assessments had weaker correlations (r s 0.49 to 0.62), as did EORn (r s 0.4 to 0.73). End-of-rotation assessments completed by supervising doctors are most highly correlated with final CCC proficiency level designations, while end-of-shift assessments and end-of-rotation assessments by nurses did not correlate strongly with final CCC proficiency levels, both with overestimation of levels noted. Every level of proficiency the CCC assigned appears to be highly correlated with the designated level in the immediate six-month period, perhaps implying CCC members are biased by previous level assignments.

  11. Random matrix theory analysis of cross-correlations in the US stock market: Evidence from Pearson’s correlation coefficient and detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan

    2013-09-01

    In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.

  12. Perme Intensive Care Unit Mobility Score and ICU Mobility Scale: translation into Portuguese and cross-cultural adaptation for use in Brazil.

    PubMed

    Kawaguchi, Yurika Maria Fogaça; Nawa, Ricardo Kenji; Figueiredo, Thais Borgheti; Martins, Lourdes; Pires-Neto, Ruy Camargo

    2016-01-01

    To translate the Perme Intensive Care Unit Mobility Score and the ICU Mobility Scale (IMS) into Portuguese, creating versions that are cross-culturally adapted for use in Brazil, and to determine the interobserver agreement and reliability for both versions. The processes of translation and cross-cultural validation consisted in the following: preparation, translation, reconciliation, synthesis, back-translation, review, approval, and pre-test. The Portuguese-language versions of both instruments were then used by two researchers to evaluate critically ill ICU patients. Weighted kappa statistics and Bland-Altman plots were used in order to verify interobserver agreement for the two instruments. In each of the domains of the instruments, interobserver reliability was evaluated with Cronbach's alpha coefficient. The correlation between the instruments was assessed by Spearman's correlation test. The study sample comprised 103 patients-56 (54%) of whom were male-with a mean age of 52 ± 18 years. The main reason for ICU admission (in 44%) was respiratory failure. Both instruments showed excellent interobserver agreement ( > 0.90) and reliability ( > 0.90) in all domains. Interobserver bias was low for the IMS and the Perme Score (-0.048 ± 0.350 and -0.06 ± 0.73, respectively). The 95% CIs for the same instruments ranged from -0.73 to 0.64 and -1.50 to 1.36, respectively. There was also a strong positive correlation between the two instruments (r = 0.941; p < 0.001). In their versions adapted for use in Brazil, both instruments showed high interobserver agreement and reliability. Realizar a tradução e a validação cultural para a língua portuguesa falada no Brasil e determinar a concordância e a confiabilidade dos instrumentos Perme Intensive Care Unit Mobility Score (designado Perme Escore) e ICU Mobility Scale (designada Escala de Mobilidade em UTI, EMU). Os processos de tradução e adaptação cultural seguiram as seguintes etapas: preparação, tradução, reconciliação, síntese, tradução reversa, revisão, aprovação e pré-teste. Após esses processos, as versões em português dos dois instrumentos foram utilizadas por dois pesquisadores na avaliação de pacientes críticos em UTI. O índice kappa ponderado e a disposição gráfica de Bland-Altman foram utilizados para verificar a concordância entre os instrumentos. O coeficiente alfa de Cronbach foi utilizado para verificar a confiabilidade entre as respostas dos avaliadores dentro de cada domínio dos instrumentos. A correlação entre os instrumentos foi verificada pelo teste de correlação de Spearman. A amostra foi composta por 103 pacientes, sendo a maioria homens (n = 56; 54%), com média de idade = 52 ± 18 anos. O principal motivo de internação nas UTIs foi insuficiência respiratória (em 44%). Os dois instrumentos apresentaram excelente concordância interobservador (> 0,90) e confiabilidade ( > 0,90) em todos os domínios. Constatou-se um baixo viés interobservador na EMU e no Perme Escore (-0,048 ± 0,350 e -0,06 ± 0,73, respectivamente). Os IC95% para os mesmos instrumentos variaram, respectivamente, de -0,73 a 0,64 e de -1,50 a 1,36, respectivamente. Além disso, verificou-se alta correlação positiva entre os dois instrumentos (r = 0,941; p < 0,001). As versões dos dois instrumentos apresentaram alta concordância e confiabilidade interobservador.

  13. Identifying presence of correlated errors in GRACE monthly harmonic coefficients using machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Piretzidis, Dimitrios; Sra, Gurveer; Karantaidis, George; Sideris, Michael G.

    2017-04-01

    A new method for identifying correlated errors in Gravity Recovery and Climate Experiment (GRACE) monthly harmonic coefficients has been developed and tested. Correlated errors are present in the differences between monthly GRACE solutions, and can be suppressed using a de-correlation filter. In principle, the de-correlation filter should be implemented only on coefficient series with correlated errors to avoid losing useful geophysical information. In previous studies, two main methods of implementing the de-correlation filter have been utilized. In the first one, the de-correlation filter is implemented starting from a specific minimum order until the maximum order of the monthly solution examined. In the second one, the de-correlation filter is implemented only on specific coefficient series, the selection of which is based on statistical testing. The method proposed in the present study exploits the capabilities of supervised machine learning algorithms such as neural networks and support vector machines (SVMs). The pattern of correlated errors can be described by several numerical and geometric features of the harmonic coefficient series. The features of extreme cases of both correlated and uncorrelated coefficients are extracted and used for the training of the machine learning algorithms. The trained machine learning algorithms are later used to identify correlated errors and provide the probability of a coefficient series to be correlated. Regarding SVMs algorithms, an extensive study is performed with various kernel functions in order to find the optimal training model for prediction. The selection of the optimal training model is based on the classification accuracy of the trained SVM algorithm on the same samples used for training. Results show excellent performance of all algorithms with a classification accuracy of 97% - 100% on a pre-selected set of training samples, both in the validation stage of the training procedure and in the subsequent use of the trained algorithms to classify independent coefficients. This accuracy is also confirmed by the external validation of the trained algorithms using the hydrology model GLDAS NOAH. The proposed method meet the requirement of identifying and de-correlating only coefficients with correlated errors. Also, there is no need of applying statistical testing or other techniques that require prior de-correlation of the harmonic coefficients.

  14. Factors That Attenuate the Correlation Coefficient and Its Analogs.

    ERIC Educational Resources Information Center

    Dolenz, Beverly

    The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…

  15. Reliability of 3D laser-based anthropometry and comparison with classical anthropometry.

    PubMed

    Kuehnapfel, Andreas; Ahnert, Peter; Loeffler, Markus; Broda, Anja; Scholz, Markus

    2016-05-26

    Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable.

  16. Regional homogeneity of fMRI time series in autism spectrum disorders.

    PubMed

    Shukla, Dinesh K; Keehn, Brandon; Müller, Ralph Axel

    2010-05-26

    Functional magnetic resonance imaging (fMRI) and functional connectivity MRI (fcMRI) studies of autism spectrum disorders (ASD) have suggested atypical patterns of activation and long-distance connectivity for diverse tasks and networks in ASD. We explored the regional homogeneity (ReHo) approach in ASD, which is analogous to conventional fcMRI, but focuses on local connectivity. FMRI data of 26 children with ASD and 29 typically developing (TD) children were acquired during continuous task performance (visual search). Effects of motion and task were removed and Kendall's coefficient of concordance (KCC) was computed, based on the correlation of the blood oxygen level dependent (BOLD) time series for each voxel and its six nearest neighbors. ReHo was lower in the ASD than the TD group in superior parietal and anterior prefrontal regions. Inverse effects of greater ReHo in the ASD group were detected in lateral and medial temporal regions, predominantly in the right hemisphere. Our findings suggest that ReHo is a sensitive measure for detecting cortical abnormalities in autism. However, impact of methodological factors (such as spatial resolution) on ReHo require further investigation. Published by Elsevier Ireland Ltd.

  17. New body fat prediction equations for severely obese patients.

    PubMed

    Horie, Lilian Mika; Barbosa-Silva, Maria Cristina Gonzalez; Torrinhas, Raquel Susana; de Mello, Marco Túlio; Cecconello, Ivan; Waitzberg, Dan Linetzky

    2008-06-01

    Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Severely obese subjects (83 female/36 male, mean age=41.6+/-11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman's graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. BF estimations from BIA (64.8+/-15 kg) and ADP (65.6+/-16.4 kg) did not differ (p>0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide limit of agreement (-10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p<0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment.

  18. Parsimonious estimation of the Wechsler Memory Scale, Fourth Edition demographically adjusted index scores: immediate and delayed memory.

    PubMed

    Miller, Justin B; Axelrod, Bradley N; Schutte, Christian

    2012-01-01

    The recent release of the Wechsler Memory Scale Fourth Edition contains many improvements from a theoretical and administration perspective, including demographic corrections using the Advanced Clinical Solutions. Although the administration time has been reduced from previous versions, a shortened version may be desirable in certain situations given practical time limitations in clinical practice. The current study evaluated two- and three-subtest estimations of demographically corrected Immediate and Delayed Memory index scores using both simple arithmetic prorating and regression models. All estimated values were significantly associated with observed index scores. Use of Lin's Concordance Correlation Coefficient as a measure of agreement showed a high degree of precision and virtually zero bias in the models, although the regression models showed a stronger association than prorated models. Regression-based models proved to be more accurate than prorated estimates with less dispersion around observed values, particularly when using three subtest regression models. Overall, the present research shows strong support for estimating demographically corrected index scores on the WMS-IV in clinical practice with an adequate performance using arithmetically prorated models and a stronger performance using regression models to predict index scores.

  19. Performance of a semi-automated approach for risk estimation using a common data model for longitudinal healthcare databases.

    PubMed

    Van Le, Hoa; Beach, Kathleen J; Powell, Gregory; Pattishall, Ed; Ryan, Patrick; Mera, Robertino M

    2013-02-01

    Different structures and coding schemes may limit rapid evaluation of a large pool of potential drug safety signals using multiple longitudinal healthcare databases. To overcome this restriction, a semi-automated approach utilising common data model (CDM) and robust pharmacoepidemiologic methods was developed; however, its performance needed to be evaluated. Twenty-three established drug-safety associations from publications were reproduced in a healthcare claims database and four of these were also repeated in electronic health records. Concordance and discrepancy of pairwise estimates were assessed between the results derived from the publication and results from this approach. For all 27 pairs, an observed agreement between the published results and the results from the semi-automated approach was greater than 85% and Kappa coefficient was 0.61, 95% CI: 0.19-1.00. Ln(IRR) differed by less than 50% for 13/27 pairs, and the IRR varied less than 2-fold for 19/27 pairs. Reproducibility based on the intra-class correlation coefficient was 0.54. Most covariates (>90%) in the publications were available for inclusion in the models. Once the study populations and inclusion/exclusion criteria were obtained from the literature, the analysis was able to be completed in 2-8 h. The semi-automated methodology using a CDM produced consistent risk estimates compared to the published findings for most selected drug-outcome associations, regardless of original study designs, databases, medications and outcomes. Further assessment of this approach is useful to understand its roles, strengths and limitations in rapidly evaluating safety signals.

  20. Normal values of 3 methods to determine patellar height in children from 6 to 12 years.

    PubMed

    Vergara-Amador, E; Davalos Herrera, D; Guevara, O A

    2018-03-26

    The aim of the study was to compare three methods for high-score measurement in children, Caton-Deschamps, Blackburne-Peel and Koshino-Sugimoto, to determine the normal value of each method in a group of normal children. A cross-sectional study on knee x-rays of normal children. Three orthopaedic surgeons measured the Caton-Deschamps, Blackburne-Peel and Koshino-Sugimoto indices. Concordance was assessed using the intraclass correlation coefficient. For interobserver variability, the measurements of each observer for each index were compared and for intraobserver variability, the coefficient between the 2 measurements was calculated by the same observer at 2 different times. 140 knee X-rays divided into 4 age groups were obtained. For the Blackburne-Peel index, an average median of the 3 observers was obtained of 1.07 and with P5-P95 (0.76-1.60). For the Caton-Deschamps index, an average median of the three observers of 1.22 was obtained and with P5-P95 (0.91-1.70). For the Koshino-Sugimoto index, we obtained an average median of the 3 observers of 1.16 and with P5-P95 (0.99-1.36). This study shows that the Koshino-Sugimoto index had the highest reliability, reproducibility and similarity in the population studied, both intra-observer and inter-observer. The other methods evaluated also had variability indices to be taken into account, but were inferior to the Koshino-Sugimoto index. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Natal dispersal and genetic structure in a population of the European wild rabbit (Oryctolagus cuniculus).

    PubMed

    Webb, N J; Ibrahim, K M; Bell, D J; Hewitt, G M

    1995-04-01

    A combination of behavioural observation, DNA fingerprinting, and allozyme analysis were used to examine natal dispersal in a wild rabbit population. Rabbits lived in territorial, warren based social groups. Over a 6-year period, significantly more male than female rabbits moved to a new social group before the start of their first breeding season. This pattern of female philopatry and male dispersal was reflected in the genetic structure of the population. DNA fingerprint band-sharing coefficients were significantly higher for females within the same group than for females between groups, while this was not the case for males. Wright's inbreeding coefficients were calculated from fingerprint band-sharing values and compared to those obtained from allozyme data. There was little correlation between the relative magnitudes of the F-statistics calculated using the two techniques for comparisons between different social groups. In contrast, two alternative methods for calculating FST from DNA fingerprints gave reasonably concordant values although those based on band-sharing were consistently lower than those calculated by an 'allele' frequency approach. A negative FIS value was obtained from allozyme data. Such excess heterozygosity within social groups is expected even under random mating given the social structure and sex-biased dispersal but it is argued that the possibility of behavioural avoidance of inbreeding should not be discounted in this species. Estimates of genetic differentiation obtained from allozyme and DNA fingerprint data agreed closely with reported estimates for the yellow-bellied marmot, a species with a very similar social structure to the European rabbit.

  2. Fast 3D magnetic resonance fingerprinting for a whole-brain coverage.

    PubMed

    Ma, Dan; Jiang, Yun; Chen, Yong; McGivney, Debra; Mehta, Bhairav; Gulani, Vikas; Griswold, Mark

    2018-04-01

    The purpose of this study was to accelerate the acquisition and reconstruction time of 3D magnetic resonance fingerprinting scans. A 3D magnetic resonance fingerprinting scan was accelerated by using a single-shot spiral trajectory with an undersampling factor of 48 in the x-y plane, and an interleaved sampling pattern with an undersampling factor of 3 through plane. Further acceleration came from reducing the waiting time between neighboring partitions. The reconstruction time was accelerated by applying singular value decomposition compression in k-space. Finally, a 3D premeasured B 1 map was used to correct for the B 1 inhomogeneity. The T 1 and T 2 values of the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI phantom showed a good agreement with the standard values, with an average concordance correlation coefficient of 0.99, and coefficient of variation of 7% in the repeatability scans. The results from in vivo scans also showed high image quality in both transverse and coronal views. This study applied a fast acquisition scheme for a fully quantitative 3D magnetic resonance fingerprinting scan with a total acceleration factor of 144 as compared with the Nyquist rate, such that 3D T 1 , T 2 , and proton density maps can be acquired with whole-brain coverage at clinical resolution in less than 5 min. Magn Reson Med 79:2190-2197, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Predictive MRI correlates of lesser metatarsophalangeal joint plantar plate tear.

    PubMed

    Umans, Rachel L; Umans, Benjamin D; Umans, Hilary; Elsinger, Elisabeth

    2016-07-01

    To identify correlated signs on non-enhanced MRI that might improve diagnostic detection of plantar plate (PP) tear. We performed an IRB-approved, HIPAA-compliant retrospective analysis of 100 non-contrast MRI (50 PP tear, 50 controls). All were anonymized, randomized, and reviewed; 20 were duplicated to assess consistency. One musculoskeletal radiologist evaluated qualitative variables. A trained non-physician performed measurements. Consistency and concordance were assessed. Pearson's Chi-square test was used to test the correlation between qualitative findings and PP tear status. Correlation between measurements and PP status was assessed using t tests and Wilcoxon's rank-sum test (p values < 0.05 considered significant). Classification and regression trees were utilized to identify attributes that, taken together, would consistently distinguish PP tear from controls. Quantitative measurements were highly reproducible (concordance 0.88-0.99). Elevated 2nd MT protrusion, lesser MT supination and rotational divergence of >45° between the 1st-2nd MT axis correlated with PP tear. Pericapsular soft tissue thickening correlated most strongly with PP tear, correctly classifying 95 % of cases and controls. Excluding pericapsular soft tissue thickening, sequential assessment of 2nd toe enthesitis, 2nd flexor tendon subluxation, and splaying of the second and third toes accurately classified PP status in 92 %. Pericapsular soft tissue thickening most strongly correlated with PP tear. For cases in which it might be difficult to distinguish pericapsular fibrosis from neuroma, sequential assessment of 2nd toe enthesitis, flexor tendon subluxation and splaying of the 2nd and 3rd toe is most helpful for optimizing accurate diagnosis of PP tear.

  4. ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients.

    PubMed

    Kim, Seongho

    2015-11-01

    Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

  5. Optimal portfolio strategy with cross-correlation matrix composed by DCCA coefficients: Evidence from the Chinese stock market

    NASA Astrophysics Data System (ADS)

    Sun, Xuelian; Liu, Zixian

    2016-02-01

    In this paper, a new estimator of correlation matrix is proposed, which is composed of the detrended cross-correlation coefficients (DCCA coefficients), to improve portfolio optimization. In contrast to Pearson's correlation coefficients (PCC), DCCA coefficients acquired by the detrended cross-correlation analysis (DCCA) method can describe the nonlinear correlation between assets, and can be decomposed in different time scales. These properties of DCCA make it possible to improve the investment effect and more valuable to investigate the scale behaviors of portfolios. The minimum variance portfolio (MVP) model and the Mean-Variance (MV) model are used to evaluate the effectiveness of this improvement. Stability analysis shows the effect of two kinds of correlation matrices on the estimation error of portfolio weights. The observed scale behaviors are significant to risk management and could be used to optimize the portfolio selection.

  6. Relationships among the slopes of lines derived from various data analysis techniques and the associated correlation coefficient

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.

    1980-01-01

    A technique for fitting a straight line to a collection of data points is given. The relationships between the slopes and correlation coefficients, and between the corresponding standard deviations and correlation coefficient are given.

  7. Determination of hemispheric dominance with mental rotation using functional transcranial Doppler sonography and FMRI.

    PubMed

    Hattemer, Katja; Plate, Annika; Heverhagen, Johannes T; Haag, Anja; Keil, Boris; Klein, Karl Martin; Hermsen, Anke; Oertel, Wolfgang H; Hamer, Hajo M; Rosenow, Felix; Knake, Susanne

    2011-01-01

    the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly. regional brain activation and hemispheric dominance during mental rotation (cube perspective test) were investigated in 10 female and 10 male healthy subjects using fMRI and fTCD. significant activation was found in the superior parietal lobe, at the parieto-occipital border, in the middle and superior frontal gyrus bilaterally, and the right inferior frontal gyrus using fMRI. Men showed a stronger lateralization to the right hemisphere during fMRI and a tendency toward stronger right-hemispheric activation during fTCD. Furthermore, more activation in frontal and parieto-occipital regions of the right hemisphere was observed using fMRI. Hemispheric dominance for mental rotation determined by the 2 methods correlated well (P= .008), but did not show concordant results in every single subject. the neural basis of mental rotation depends on a widespread bilateral network. Hemispheric dominance for mental rotation determined by fMRI and fTCD, though correlating well, is not always concordant. Hemispheric lateralization of complex cortical functions such as spatial rotation therefore should be investigated using multimodal imaging approaches, especially if used clinically as a tool for the presurgical evaluation of patients undergoing neurosurgery. Copyright © 2009 by the American Society of Neuroimaging.

  8. Estimation of glycaemic control in the past month using ratio of glycated albumin to HbA1c.

    PubMed

    Musha, I; Mochizuki, M; Kikuchi, T; Akatsuka, J; Ohtake, A; Kobayashi, K; Kikuchi, N; Kawamura, T; Yokota, I; Urakami, T; Sugihara, S; Amemiya, S

    2018-04-13

    To evaluate comprehensively the use of the glycated albumin to HbA 1c ratio for estimation of glycaemic control in the previous month. A total of 306 children with Type 1 diabetes mellitus underwent ≥10 simultaneous measurements of glycated albumin and HbA 1c . Correlation and concordance rates were examined between HbA 1c measurements taken 1 month apart (ΔHbA 1c ) and glycated albumin/HbA 1c ratio fluctuations were calculated as Z-scores from the cohort value at enrolment of this study cohort (method A) or the percent difference from the individual mean over time (method B). Fluctuations in glycated albumin/HbA 1c ratio (using both methods) were weakly but significantly correlated with ΔHbA 1c , whereas concordance rates were significant for glycaemic deterioration but not for glycaemic improvement. Concordance rates were higher using method B than method A. The glycated albumin/HbA 1c ratio was able to estimate glycaemic deterioration in the previous month, while estimation of glycaemic improvement in the preceding month was limited. Because method B provided a better estimate of recent glycaemic control than method A, the individual mean of several measurements of the glycated albumin/HbA 1c ratio over time may also identify individuals with high or low haemoglobin glycation phenotypes in a given population, such as Japanese children with Type 1 diabetes, thereby allowing more effective diabetes management. © 2018 Diabetes UK.

  9. Dual-colour HER2/chromosome 17 chromogenic in situ hybridisation enables accurate assessment of HER2 genomic status in ovarian tumours.

    PubMed

    Yan, Benedict; Choo, Shoa Nian; Mulyadi, Patricia; Srivastava, Supriya; Ong, Chee Wee; Yong, Kol Jia; Putti, Thomas; Salto-Tellez, Manuel; Lim, Gkeok Stzuan Diana

    2011-12-01

    Ovarian cancer is a leading cause of gynaecological cancer-related morbidity and mortality. There has been increasing interest in the potential utility of anti-human epidermal growth factor receptor 2 (anti-HER2) agents in the treatment of this disease, with the attendant need to identify suitable predictive biomarkers of response to treatment. The authors studied the prevalence of HER2 genomic amplification and overexpression in 85 ovarian tumours in the local patient cohort of this study, as well as the concordance rate between immunohistochemistry, fluorescent in situ hybridisation (FISH) and a dual-colour HER2/chromosome 17 centromere chromogenic in situ hybridisation (CISH) assay. The authors identified HER2 genomic amplification and protein overexpression in 35.3% (6/17) and 29.4% (5/17), respectively, of primary ovarian mucinous carcinomas. No other cancer subtypes displayed HER2 amplification or protein overexpression. The authors also found a perfect concordance between FISH and dual-colour CISH analysis (κ coefficient 1.0, p<0.001). The results of this study support existing reports that HER2 genomic amplification and protein overexpression are predominantly found in primary ovarian mucinous carcinomas. Given the perfect concordance between the FISH and dual-colour CISH assays and the advantages of CISH over FISH analysis, future clinical trials investigating the use of anti-HER2 therapeutics in ovarian carcinomas should incorporate dual-colour CISH as part of the HER2 status assessment algorithm.

  10. Correlation Between Minimum Apparent Diffusion Coefficient (ADCmin) and Tumor Cellularity: A Meta-analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-07-01

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  11. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    PubMed

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  12. Criterion and Concurrent Validity of the activPAL™ Professional Physical Activity Monitor in Adolescent Females

    PubMed Central

    Dowd, Kieran P.; Harrington, Deirdre M.; Donnelly, Alan E.

    2012-01-01

    Background The activPAL has been identified as an accurate and reliable measure of sedentary behaviour. However, only limited information is available on the accuracy of the activPAL activity count function as a measure of physical activity, while no unit calibration of the activPAL has been completed to date. This study aimed to investigate the criterion validity of the activPAL, examine the concurrent validity of the activPAL, and perform and validate a value calibration of the activPAL in an adolescent female population. The performance of the activPAL in estimating posture was also compared with sedentary thresholds used with the ActiGraph accelerometer. Methodologies Thirty adolescent females (15 developmental; 15 cross-validation) aged 15–18 years performed 5 activities while wearing the activPAL, ActiGraph GT3X, and the Cosmed K4B2. A random coefficient statistics model examined the relationship between metabolic equivalent (MET) values and activPAL counts. Receiver operating characteristic analysis was used to determine activity thresholds and for cross-validation. The random coefficient statistics model showed a concordance correlation coefficient of 0.93 (standard error of the estimate = 1.13). An optimal moderate threshold of 2997 was determined using mixed regression, while an optimal vigorous threshold of 8229 was determined using receiver operating statistics. The activPAL count function demonstrated very high concurrent validity (r = 0.96, p<0.01) with the ActiGraph count function. Levels of agreement for sitting, standing, and stepping between direct observation and the activPAL and ActiGraph were 100%, 98.1%, 99.2% and 100%, 0%, 100%, respectively. Conclusions These findings suggest that the activPAL is a valid, objective measurement tool that can be used for both the measurement of physical activity and sedentary behaviours in an adolescent female population. PMID:23094069

  13. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures

    PubMed Central

    Someswara Rao, Chinta; Viswanadha Raju, S.

    2016-01-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc. PMID:26981409

  14. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures.

    PubMed

    Someswara Rao, Chinta; Viswanadha Raju, S

    2016-03-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.

  15. Divisional role of quantitative HER2 testing in breast cancer.

    PubMed

    Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fu, Peifen; Yamamoto, Satoko; Fujiwara, Saori; Honda, Yumi; Iyama, Ken-ichi; Iwase, Hirotaka

    2015-03-01

    Human epidermal growth factor receptor 2 (HER2) is amplified in human breast cancers in which therapy targeted to HER2 significantly improves patient outcome. We re-visited the use of real-time quantitative polymerase chain reaction (qPCR)-based assays using formalin-fixed paraffin-embedded (FFPE) tissues as alternative methods and investigated their particular clinical relevance. DNA and RNA were isolated from FFPE specimens and HER2 status was assessed by qPCR in 249 consecutive patients with primary breast cancer. Concordance with results forg immunohistochemistry (IHC) and in situ hybridization (ISH), clinical characteristics and survival was assessed. HER2 gene copy number had a stronger correlation with clinicopathological characteristics and excellent concordance with IHC/ISH results (Sensitivity: 96.7 %; concordance: 99.2 %). HER2 gene expression showed inadequate sensitivity, rendering it unsuitable to determine HER2 status (Sensitivity: 46.7 %; concordance: 92.1 %), but lower HER2 gene expression, leading to the classification of many cases as "false negative", contributed to a prediction of better prognosis within the HER2-amplified subpopulation. Quantitative HER2 assessments are suggested to have evolved their accuracy in this decade, which can be a potential alternative for HER2 diagnosis in line with the in situ method, while HER2 gene expression levels could provide additional information regarding prognosis or therapeutic strategy within a HER2-amplified subpopulation.

  16. Characterizing the Relationship Between Surgical Resident and Faculty Perceptions of Autonomy in the Operating Room.

    PubMed

    Young, Katelyn A; Lane, Samantha M; Widger, John E; Neuhaus, Nina M; Dove, James T; Fluck, Marcus; Hunsinger, Marie A; Blansfield, Joseph A; Shabahang, Mohsen M

    Characterize the concordance among faculty and resident perceptions of surgical case complexity, resident technical performance, and autonomy in a diverse sample of general surgery procedures using case-specific evaluations. A prospective study was conducted in which a faculty surgeon and surgical resident independently completed a postoperative assessment examining case complexity, resident operative performance (Milestone assessment) and autonomy (Zwisch model). Pearson correlation coefficients (r) reaching statistical significance (p < 0.05) were further classified as moderate (r ≥ 0.40), strong (r ≥ 0.60), or very strong (r ≥ 0.80). This study was conducted in the General Surgery Residency Program at an academic tertiary care facility (Geisinger Medical Center, Danville, PA). Participants included 6 faculty surgeons, in addition to 5 postgraduate year (PGY) 1, 6 midlevel (PGY 2-3), and 4 chief (PGY 4-5) residents. In total, 75 surgical cases were analyzed. Midlevel residents accounted for the highest number of cases (35, 46.6%). Overall, faculty and resident perceptions of case complexity demonstrated a strong correlation (r = 0.76, p < 0.0001). Technical performance scores were also strongly correlated (r = 0.66, p < 0.0001), whereas perceptions of autonomy demonstrated a moderate correlation (r = 0.56, p < 0.0001). Subgroup analysis revealed very strong correlations among faculty perceptions of case complexity and the perceptions of PGY 1 (r = 0.80, p < 0.0001) and chief residents (r = 0.82, p < 0.0001). All other intergroup correlations were strong with 2 notable exceptions as follows: midlevel and chief residents failed to correlate with faculty perceptions of autonomy and operative performance, respectively. General surgery residents generally demonstrated high correlations with faculty perceptions of case complexity, technical performance, and operative autonomy. This generalized accord supports the use of the Milestone and Zwisch assessments in residency programs. However, discordance among perceptions of midlevel resident autonomy and chief resident operative performance suggests that these trainees may need more direct communication from the faculty. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. The Role of Parent-Adolescent Concordance in Compliance with Cancer Chemotherapy.

    ERIC Educational Resources Information Center

    Tebbi, Cameron K.; And Others

    1988-01-01

    Studied 16 parent/adolescent cancer patient pairs on their knowledge and understanding of illness, medications and treatments, and their medication compliance. Found that adolescent responses closely matched those of their parents on all topics. Age was positively correlated with agreement for medication instructions. Findings have implications…

  18. Diagnostic accuracy of MRI in the measurement of glenoid bone loss.

    PubMed

    Gyftopoulos, Soterios; Hasan, Saqib; Bencardino, Jenny; Mayo, Jason; Nayyar, Samir; Babb, James; Jazrawi, Laith

    2012-10-01

    The purpose of this study is to assess the accuracy of MRI quantification of glenoid bone loss and to compare the diagnostic accuracy of MRI to CT in the measurement of glenoid bone loss. MRI, CT, and 3D CT examinations of 18 cadaveric glenoids were obtained after the creation of defects along the anterior and anteroinferior glenoid. The defects were measured by three readers separately and blindly using the circle method. These measurements were compared with measurements made on digital photographic images of the cadaveric glenoids. Paired sample Student t tests were used to compare the imaging modalities. Concordance correlation coefficients were also calculated to measure interobserver agreement. Our data show that MRI could be used to accurately measure glenoid bone loss with a small margin of error (mean, 3.44%; range, 2.06-5.94%) in estimated percentage loss. MRI accuracy was similar to that of both CT and 3D CT for glenoid loss measurements in our study for the readers familiar with the circle method, with 1.3% as the maximum expected difference in accuracy of the percentage bone loss between the different modalities (95% confidence). Glenoid bone loss can be accurately measured on MRI using the circle method. The MRI quantification of glenoid bone loss compares favorably to measurements obtained using 3D CT and CT. The accuracy of the measurements correlates with the level of training, and a learning curve is expected before mastering this technique.

  19. Development and validation of a tool to evaluate the quality of medical education websites in pathology.

    PubMed

    Alyusuf, Raja H; Prasad, Kameshwar; Abdel Satir, Ali M; Abalkhail, Ali A; Arora, Roopa K

    2013-01-01

    The exponential use of the internet as a learning resource coupled with varied quality of many websites, lead to a need to identify suitable websites for teaching purposes. The aim of this study is to develop and to validate a tool, which evaluates the quality of undergraduate medical educational websites; and apply it to the field of pathology. A tool was devised through several steps of item generation, reduction, weightage, pilot testing, post-pilot modification of the tool and validating the tool. Tool validation included measurement of inter-observer reliability; and generation of criterion related, construct related and content related validity. The validated tool was subsequently tested by applying it to a population of pathology websites. Reliability testing showed a high internal consistency reliability (Cronbach's alpha = 0.92), high inter-observer reliability (Pearson's correlation r = 0.88), intraclass correlation coefficient = 0.85 and κ =0.75. It showed high criterion related, construct related and content related validity. The tool showed moderately high concordance with the gold standard (κ =0.61); 92.2% sensitivity, 67.8% specificity, 75.6% positive predictive value and 88.9% negative predictive value. The validated tool was applied to 278 websites; 29.9% were rated as recommended, 41.0% as recommended with caution and 29.1% as not recommended. A systematic tool was devised to evaluate the quality of websites for medical educational purposes. The tool was shown to yield reliable and valid inferences through its application to pathology websites.

  20. Concordance of self-report and measured height and weight of college students.

    PubMed

    Quick, Virginia; Byrd-Bredbenner, Carol; Shoff, Suzanne; White, Adrienne A; Lohse, Barbara; Horacek, Tanya; Kattelmann, Kendra; Phillips, Beatrice; Hoerr, Sharon L; Greene, Geoffrey

    2015-01-01

    This study examined associations between college students' self-report and measured height and weight. Participants (N = 1,686) were 77% white, 62% female, aged 18-24 years (mean ± SD, 19.1 ± 1.1 years), and enrolled at 8 US universities. Body mass index (BMI) was calculated for self-report (via online survey); trained researchers measured height and weight and categorized them as normal (18.5 to < 25), overweight (25 to < 30), obese (30 to < 35), and morbidly obese (≥ 35). Concordance of self-report vs objectively measured BMI groups using chi-square revealed that 93% were accurate, 4% were underestimated, and 2.7% were overestimated. Pearson correlations and adjusted linear regression revealed significant associations between self-report and measured BMI (r = .97; P < .001) and BMI adjusted for age, gender, and race/ethnicity (R² = .94). Concordance was also high between BMI categories (kappa = 0.77; P < .001). Findings provide support for the utility of self-report height and weight for survey research in college students. Copyright © 2015 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  1. [Reliability and reproducibility of the Fitzpatrick phototype scale for skin sensitivity to ultraviolet light].

    PubMed

    Sánchez, Guillermo; Nova, John; Arias, Nilsa; Peña, Bibiana

    2008-12-01

    The Fitzpatrick phototype scale has been used to determine skin sensitivity to ultraviolet light. The reliability of this scale in estimating sensitivity permits risk evaluation of skin cancer based on phototype. Reliability and changes in intra and inter-observer concordance was determined for the Fitzpatrick phototype scale after the assessment methods for establishing the phototype were standardized. An analytical study of intra and inter-observer concordance was performed. The Fitzpatrick phototype scale was standardized using focus group methodology. To determine intra and inter-observer agreement, the weighted kappa statistical method was applied. The standardization effect was measured using the equal kappa contrast hypothesis and Wald test for dependent measurements. The phototype scale was applied to 155 patients over 15 years of age who were assessed four times by two independent observers. The sample was drawn from patients of the Centro Dermatol6gico Federico Lleras Acosta. During the pre-standardization phase, the baseline and six-week inter-observer weighted kappa were 0.31 and 0.40, respectively. The intra-observer kappa values for observers A and B were 0.47 and 0.51, respectively. After the standardization process, the baseline and six-week inter-observer weighted kappa values were 0.77, and 0.82, respectively. Intra-observer kappa coefficients for observers A and B were 0.78 and 0.82. Statistically significant differences were found between coefficients before and after standardization (p<0.001) in all comparisons. Following a standardization exercise, the Fitzpatrick phototype scale yielded reliable, reproducible and consistent results.

  2. Development of a clinical diagnostic matrix for characterizing inherited epidermolysis bullosa.

    PubMed

    Yenamandra, V K; Moss, C; Sreenivas, V; Khan, M; Sivasubbu, S; Sharma, V K; Sethuraman, G

    2017-06-01

    Accurately diagnosing the subtype of epidermolysis bullosa (EB) is critical for management and genetic counselling. Modern laboratory techniques are largely inaccessible in developing countries, where the diagnosis remains clinical and often inaccurate. To develop a simple clinical diagnostic tool to aid in the diagnosis and subtyping of EB. We developed a matrix indicating presence or absence of a set of distinctive clinical features (as rows) for the nine most prevalent EB subtypes (as columns). To test an individual patient, presence or absence of these features was compared with the findings expected in each of the nine subtypes to see which corresponded best. If two or more diagnoses scored equally, the diagnosis with the greatest number of specific features was selected. The matrix was tested using findings from 74 genetically characterized patients with EB aged > 6 months by an investigator blinded to molecular diagnosis. For concordance, matrix diagnoses were compared with molecular diagnoses. Overall, concordance between the matrix and molecular diagnoses for the four major types of EB was 91·9%, with a kappa coefficient of 0·88 [95% confidence interval (CI) 0·81-0·95; P < 0·001]. The matrix achieved a 75·7% agreement in classifying EB into its nine subtypes, with a kappa coefficient of 0·73 (95% CI 0·69-0·77; P < 0·001). The matrix appears to be simple, valid and useful in predicting the type and subtype of EB. An electronic version will facilitate further testing. © 2016 British Association of Dermatologists.

  3. Correlation coefficient measurement of the mode-locked laser tones using four-wave mixing.

    PubMed

    Anthur, Aravind P; Panapakkam, Vivek; Vujicic, Vidak; Merghem, Kamel; Lelarge, Francois; Ramdane, Abderrahim; Barry, Liam P

    2016-06-01

    We use four-wave mixing to measure the correlation coefficient of comb tones in a quantum-dash mode-locked laser under passive and active locked regimes. We study the uncertainty in the measurement of the correlation coefficient of the proposed method.

  4. Challenge of assessing symptoms in seriously ill intensive care unit patients: can proxy reporters help?

    PubMed

    Puntillo, Kathleen A; Neuhaus, John; Arai, Shoshana; Paul, Steven M; Gropper, Michael A; Cohen, Neal H; Miaskowski, Christine

    2012-10-01

    Determine levels of agreement among intensive care unit patients and their family members, nurses, and physicians (proxies) regarding patients' symptoms and compare levels of mean intensity (i.e., the magnitude of a symptom sensation) and distress (i.e., the degree of emotionality that a symptom engenders) of symptoms among patients and proxy reporters. Prospective study of proxy reporters of symptoms in seriously ill patients. Two intensive care units in a tertiary medical center in the Western United States. Two hundred and forty-five intensive care unit patients, 243 family members, 103 nurses, and 92 physicians. None. On the basis of the magnitude of intraclass correlation coefficients, where coefficients from .35 to .78 are considered to be appropriately robust, correlation coefficients between patients' and family members' ratings met this criterion (≥.35) for intensity in six of ten symptoms. No intensity ratings between patients and nurses had intraclass correlation coefficients >.32. Three symptoms had intensity correlation coefficients of ≥.36 between patients' and physicians' ratings. Correlation coefficients between patients and family members were >.40 for five symptom-distress ratings. No symptoms had distress correlation coefficients of ≥.28 between patients' and nurses' ratings. Two symptoms had symptom-distress correlation coefficients between patients' and physicians' ratings at >.39. Family members, nurses, and physicians reported higher symptom-intensity scores than patients did for 80%, 60%, and 60% of the symptoms, respectively. Family members, nurses, and physicians reported higher symptom-distress scores than patients did for 90%, 70%, and 80% of the symptoms, respectively. Patient-family intraclass correlation coefficients were sufficiently close for us to consider using family members to help assess intensive care unit patients' symptoms. Relatively low intraclass correlation coefficients between intensive care unit clinicians' and patients' symptom ratings indicate that some proxy raters overestimate whereas others underestimate patients' symptoms. Proxy overestimation of patients' symptom scores warrants further study because this may influence decisions about treating patients' symptoms.

  5. Shortening the incubation time for the combination disk diffusion extended-spectrum β-lactamase (ESBL) confirmation test: how far can we go?

    PubMed

    van den Bijllaardt, Wouter; Voermans, Patricia C M; Buiting, Anton G; Mouton, Johan W; Muller, Anouk E

    2017-09-01

    The combination disk diffusion extended-spectrum β-lactamase (ESBL) confirmation test (CDT) is used for the confirmation of ESBL production in Enterobacteriaceae and usually takes 16-20 h to results. In this study, we searched for the shortest possible incubation time without a reduction in reliability. A total of 125 ESBL screening-positive isolates were subjected to CDT and were molecularly characterised by microarray. Inhibition zones were read every hour over 6-18 h of incubation. Concordance between earlier and 18-h readings was calculated for each hour. Results were validated on 224 isolates during routine clinical practice. For the initial 125 isolates, concordance (Cohen's κ) between the 6-h and 18-h readings was 0.88 [95% confidence interval (CI) 0.78-0.96; P <0.001]. The earliest time point for full concordance with the 18-h reading was 10 h. Validation of the 10-h reading for 224 clinical isolates resulted in a concordance of 0.99 (95% CI 0.98-1.0) between the 10-h and 18-h readings. Overall concordance on all 349 isolates was 0.99 (95% CI 0.97-1.0). Reading after 10 h of incubation has an excellent correlation with results after 18 h of incubation. This can significantly reduce the turnaround time for ESBL detection in laboratories with long opening hours or providing a 24/7 service. Consequently, there is a potential for implementing infection control measures up to 8 h earlier. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  6. Child and Caregiver Concordance of Potentially Traumatic Events Experienced by Orphaned and Abandoned Children

    PubMed Central

    Guru Rajan, Divya; Shirey, Kristen; Ostermann, Jan; Whetten, Rachel; O’Donnell, Karen; Whetten, Kathryn

    2013-01-01

    Exposure to trauma is associated with significant emotional and behavioral difficulties among children (Perepletchikova & Kaufman, 2010). Overall, reports of trauma and violence experienced by children are discrepant from those of their caregivers (Lewis et al., 2012). Even less is known about the extent of concordance between orphans and their caregivers. This study examines the correlates of concordance in reported traumatic experiences between 1,269 orphaned and abandoned children (OAC) and their caregivers. The OAC lived in family-settings in 5 low and middle income countries and were part of a longitudinal study, “Positive Outcomes for Orphans” (POFO) that enrolled children aged 6 to 12 at baseline. By examining concordance with respect to specific types of trauma reported, this study expands the understanding of who reports which types of traumas experienced by orphaned and abandoned children, thereby improving the potential to provide targeted interventions for children who have experienced such events. In this study, children and caregivers were asked separately if the child had experienced different types of potentially traumatic events. Children were significantly more likely to report physical abuse, sexual abuse and family violence than were caregivers. Caregivers were significantly more likely than children to report natural disasters and accidents. High levels of concordance were found in the reporting of wars, riots, killings, and deaths in the family. The impacts of trauma on behavior and mental health are profound, and highly effective interventions targeting sequelae of childhood trauma are currently being developed for use in low resource areas. Findings from this study demonstrate that it is feasible to conduct screening for potentially traumatic events utilizing child self-report in resource limited settings and that child self-report is crucial in evaluating trauma, particularly family violence and physical or sexual assault. PMID:25379051

  7. Average effect estimates remain similar as evidence evolves from single trials to high-quality bodies of evidence: a meta-epidemiologic study.

    PubMed

    Gartlehner, Gerald; Dobrescu, Andreea; Evans, Tammeka Swinson; Thaler, Kylie; Nussbaumer, Barbara; Sommer, Isolde; Lohr, Kathleen N

    2016-01-01

    The objective of our study was to use a diverse sample of medical interventions to assess empirically whether first trials rendered substantially different treatment effect estimates than reliable, high-quality bodies of evidence. We used a meta-epidemiologic study design using 100 randomly selected bodies of evidence from Cochrane reports that had been graded as high quality of evidence. To determine the concordance of effect estimates between first and subsequent trials, we applied both quantitative and qualitative approaches. For quantitative assessment, we used Lin's concordance correlation and calculated z-scores; to determine the magnitude of differences of treatment effects, we calculated standardized mean differences (SMDs) and ratios of relative risks. We determined qualitative concordance based on a two-tiered approach incorporating changes in statistical significance and magnitude of effect. First trials both overestimated and underestimated the true treatment effects in no discernible pattern. Nevertheless, depending on the definition of concordance, effect estimates of first trials were concordant with pooled subsequent studies in at least 33% but up to 50% of comparisons. The pooled magnitude of change as bodies of evidence advanced from single trials to high-quality bodies of evidence was 0.16 SMD [95% confidence interval (CI): 0.12, 0.21]. In 80% of comparisons, the difference in effect estimates was smaller than 0.5 SMDs. In first trials with large treatment effects (>0.5 SMD), however, estimates of effect substantially changed as new evidence accrued (mean change 0.68 SMD; 95% CI: 0.50, 0.86). Results of first trials often change, but the magnitude of change, on average, is small. Exceptions are first trials that present large treatment effects, which often dissipate as new evidence accrues. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Chronic kidney disease among high school students of Kinshasa

    PubMed Central

    2012-01-01

    Background Chronic kidney disease (CKD) is a major worldwide health problem. However, its burden among adolescents and young adults is unknown, especially in sub-Saharan Africa. The aim of this study was to investigate its prevalence in the school environment. The concordance of usual formulas used to estimate renal function was also assessed. Methods In an epidemiological cross sectional study, a random sample of 524 pupils (263 boys, mean age of 18.7 ± 1.4 years) from school environment of Kinshasa were studied. Recorded parameters of interest were anthropometric, proteinuria, serum creatinine and estimated glomerular filtration rate (eGFR) according to the Schwartz formula using uncalibrated creatinine levels from one random measurement. CKD was defined as the presence of kidney damage (daily proteinuria ≥ 300 mg) and/or reduced kidney function (eGFR < 60 ml/min/1.73 m2). Concordances between eGFR according to Schwartz, Cockcroft-Gault (C-G) indexed for BSA and modification of diet in renal disease (MDRD) study equations were computed using the kappa coefficient. Results The prevalence of CKD by the Schwartz formula was 1.5%. By stage, 0.8% had CKD stage 1 (proteinuria with normal eGFR) and 0.8% had CKD stage 3 (eGFR, 30 to 59 ml/min/1.73 m2). The prevalence of proteinuria ≥ 300 mg/day was 1% (one case had 2.7g/day). Agreement between eGFR according to Schwartz formula and the MDRD formula was excellent (kappa: 88.8%). Although correlations between all formulas were excellent (0.99; 0.87, and 0.89), agreement was poor between eGFR according to Schwartz and C-G indexed BSA equation (kappa: 52.7%) and, poorer with C-G unadjusted for BSA (kappa: 26.9%). Conclusion In the large African city of Kinshasa, 2% of high school students have CKD. This high prevalence rate emphasizes the need for appropriate detection and prevention measures in this vulnerable young age population group. PMID:22559052

  9. Optimization and field use of a bioassay to monitor sea lice Lepeophtheirus salmonis sensitivity to emamectin benzoate.

    PubMed

    Westcott, Jillian D; Stryhn, Henrik; Burka, John F; Hammell, K Larry

    2008-04-01

    A bioassay for sea lice Lepeophtheirus salmonis sensitivity towards emamectin benzoate (EMB) was validated for field use. A probit regression model with natural responsiveness was used for the number of affected (moribund or dead) sea lice in bioassays involving different concentrations of EMB. Bioassay optimization included an evaluation of the inter-rater reliability of sea lice responsiveness to EMB and an evaluation of gender-related differences in susceptibility. Adoption of a set of bioassay response criteria improved the concordance (evaluated using the concordance correlation coefficient) between raters' assessments and the model estimation of EC50 values (the 'effective concentration' leading to a response of 50% of the lice not prone to natural response). An evaluation of gender-related differences in EMB susceptibility indicated that preadult stage female sea lice exhibited a significantly larger sensitivity towards EMB in 12 of 19 bioassays compared to preadult males. In order to evaluate sea lice sensitivity to EMB in eastern Canada, the intensive salmon farming area in the Bay of Fundy in southwestern New Brunswick was divided into 4 distinct regions based on industry health management practices and hydrographics. A total of 38 bioassays were completed from 2002 to 2005 using populations of preadult stage sea lice collected from Atlantic salmon Salmo salar farms within the 4 described regions. There was no significant overall effect of region or year on EC50 values; however, analysis of variance indicated a significant effect of time of year on EC50 values in 2002 and a potential effect in 2004 to 2005. Although the range of EC50 values obtained in this 3 yr study did not appear sufficient to affect current clinical success in the control of sea lice, the results suggest a seasonal- or temperature-associated variation in sensitivity to EMB. This will need to be considered if changes in EMB efficacy occur in the future.

  10. Association between Social Network Characteristics and Lifestyle Behaviours in Adults at Risk of Diabetes and Cardiovascular Disease.

    PubMed

    Bot, Sandra D; Mackenbach, Joreintje D; Nijpels, Giel; Lakerveld, Jeroen

    2016-01-01

    In this exploratory study we examined the associations between several social network characteristics and lifestyle behaviours in adults at increased risk of diabetes and cardiovascular diseases. In addition, we explored whether similarities in lifestyle between individuals and their network members, or the level of social support perceived by these individuals, could explain these associations. From the control group of the Hoorn Prevention Study, participants with high and low educational attainment were approached for a structured interview between April and August 2010. Inclusion was stopped when fifty adults agreed to participate. Participants and a selection of their network members (e.g. spouses, best friends, neighbours, colleagues) completed a questionnaire on healthy lifestyle that included questions on fruit and vegetable intake, daily physical activity and leisure-time sedentary behaviour. We first examined associations between network characteristics and lifestyle using regression analyses. Second, we assessed associations between network characteristics and social support, social support and lifestyle, and compared the participants' lifestyles to those of their network members using concordance correlation coefficients. Fifty adults (50/83 x 100 = 62% response) and 170 of their network members (170/192 x 100 = 89% response) participated in the study. Individuals with more close-knit relationships, more friends who live nearby, and a larger and denser network showed higher levels of vegetable consumption and physical activity, and lower levels of sedentary behaviour. Perceived social norms or perceived support for behavioural change were not related to healthy lifestyle. Except for spousal concordance for vegetable intake, the lifestyle of individuals and their network members were not alike. Study results suggest that adults with a larger and denser social network have a healthier lifestyle. Underlying mechanisms for these associations should be further explored, as the current results suggest a minimal role for social support and modelling by network members.

  11. Development and preliminary evaluation of a practice-based learning and improvement tool for assessing resident competence and guiding curriculum development.

    PubMed

    Lawrence, Renée H; Tomolo, Anne M

    2011-03-01

    Although practice-based learning and improvement (PBLI) is now recognized as a fundamental and necessary skill set, we are still in need of tools that yield specific information about gaps in knowledge and application to help nurture the development of quality improvement (QI) skills in physicians in a proficient and proactive manner. We developed a questionnaire and coding system as an assessment tool to evaluate and provide feedback regarding PBLI self-efficacy, knowledge, and application skills for residency programs and related professional requirements. Five nationally recognized QI experts/leaders reviewed and completed our questionnaire. Through an iterative process, a coding system based on identifying key variables needed for ideal responses was developed to score project proposals. The coding system comprised 14 variables related to the QI projects, and an additional 30 variables related to the core knowledge concepts related to PBLI. A total of 86 residents completed the questionnaire, and 2 raters coded their open-ended responses. Interrater reliability was assessed by percentage agreement and Cohen κ for individual variables and Lin concordance correlation for total scores for knowledge and application. Discriminative validity (t test to compare known groups) and coefficient of reproducibility as an indicator of construct validity (item difficulty hierarchy) were also assessed. Interrater reliability estimates were good (percentage of agreements, above 90%; κ, above 0.4 for most variables; concordances for total scores were R  =  .88 for knowledge and R  =  .98 for application). Despite the residents' limited range of experiences in the group with prior PBLI exposure, our tool met our goal of differentiating between the 2 groups in our preliminary analyses. Correcting for chance agreement identified some variables that are potentially problematic. Although additional evaluation is needed, our tool may prove helpful and provide detailed information about trainees' progress and the curriculum.

  12. Development and Preliminary Evaluation of a Practice-Based Learning and Improvement Tool for Assessing Resident Competence and Guiding Curriculum Development

    PubMed Central

    Lawrence, Renée H; Tomolo, Anne M

    2011-01-01

    Background Although practice-based learning and improvement (PBLI) is now recognized as a fundamental and necessary skill set, we are still in need of tools that yield specific information about gaps in knowledge and application to help nurture the development of quality improvement (QI) skills in physicians in a proficient and proactive manner. We developed a questionnaire and coding system as an assessment tool to evaluate and provide feedback regarding PBLI self-efficacy, knowledge, and application skills for residency programs and related professional requirements. Methods Five nationally recognized QI experts/leaders reviewed and completed our questionnaire. Through an iterative process, a coding system based on identifying key variables needed for ideal responses was developed to score project proposals. The coding system comprised 14 variables related to the QI projects, and an additional 30 variables related to the core knowledge concepts related to PBLI. A total of 86 residents completed the questionnaire, and 2 raters coded their open-ended responses. Interrater reliability was assessed by percentage agreement and Cohen κ for individual variables and Lin concordance correlation for total scores for knowledge and application. Discriminative validity (t test to compare known groups) and coefficient of reproducibility as an indicator of construct validity (item difficulty hierarchy) were also assessed. Results Interrater reliability estimates were good (percentage of agreements, above 90%; κ, above 0.4 for most variables; concordances for total scores were R  =  .88 for knowledge and R  =  .98 for application). Conclusion Despite the residents' limited range of experiences in the group with prior PBLI exposure, our tool met our goal of differentiating between the 2 groups in our preliminary analyses. Correcting for chance agreement identified some variables that are potentially problematic. Although additional evaluation is needed, our tool may prove helpful and provide detailed information about trainees' progress and the curriculum. PMID:22379522

  13. Comparison of Two Sources of Clinical Audit Data to Assess the Delivery of Diabetes Care in Aboriginal Communities.

    PubMed

    Regan, Timothy; Paul, Christine; Ishiguchi, Paul; D'Este, Catherine; Koller, Claudia; Forshaw, Kristy; Noble, Natasha; Oldmeadow, Christopher; Bisquera, Alessandra; Eades, Sandra

    2017-10-17

    The objective of this study was to determine the concordance between data extracted from two Clinical Decision Support Systems regarding diabetes testing and monitoring at Aboriginal Community Controlled Health Services in Australia. De-identified PenCAT and Communicare Systems data were extracted from the services allocated to the intervention arm of a diabetes care trial, and intra-class correlations for each extracted item were derived at a service level. Strong to very strong correlations between the two data sources were found regarding the total number of patients with diabetes per service (Intra-class correlation [ICC] = 0.99), as well as the number (ICC = 0.98-0.99) and proportion (ICC = 0.96) of patients with diabetes by gender. The correlation was moderate for the number and proportion of Type 2 diabetes patients per service in the group aged 18-34 years (ICC = 0.65 and 0.8-0.82 respectively). Strong to very strong correlations were found for numbers and proportions of patients being tested for diabetes, and for appropriate monitoring of patients known to have diabetes (ICC = 0.998-1.00). This indicated a generally high degree of concordance between whole-service data extracted by the two Clinical Decision Support Systems. Therefore, the less expensive or less complex option (depending on the individual circumstances of the service) may be appropriate for monitoring diabetes testing and care. However, the extraction of data about subgroups of patients may not be interchangeable.

  14. Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.

    PubMed

    Rastegar, Seyed Omid; Gu, Tingyue

    2017-03-24

    In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    ERIC Educational Resources Information Center

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  16. Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals

    PubMed Central

    Maggio, Marcello; Ceda, Gian Paolo; Ticinesi, Andrea; De Vita, Francesca; Gelmini, Giovanni; Costantino, Cosimo; Meschi, Tiziana; Kressig, Reto W.; Cesari, Matteo; Fabi, Massimo; Lauretani, Fulvio

    2016-01-01

    Background Manual measurement of 4-meter gait speed by a stopwatch is the gold standard test for functional assessment in older adults. However, the accuracy of this technique may be biased by several factors, including intra- and inter-operator variability. Instrumental techniques of measurement using accelerometers may have a higher accuracy. Studies addressing the concordance between these two techniques are missing. The aim of the present community-based observational study was to compare manual and instrumental measurements of 4-meter gait speed in older individuals and to assess their relationship with other indicators of physical performance. Methods One-hundred seventy-two (69 men, 103 women) non-disabled community-dwellers aged ≥65 years were enrolled. They underwent a comprehensive geriatric assessment including physical function by Short Physical Performance Battery (SPPB), hand grip strength, and 6-minute walking test (6MWT). Timed usual walking speed on a 4-meter course was assessed by using both a stopwatch (4-meter manual measurement, 4-MM) and a tri-axial accelerometer (4-meter automatic measurement, 4-MA). Correlations between these performance measures were evaluated separately in men and women by partial correlation coefficients. Results In both genders, 4-MA was associated with 4-MM (men r = 0.62, p<0.001; women r = 0.73, p<0.001), handgrip strength (men r = 0.40, p = 0.005; women r = 0.29, p = 0.001) and 6MWT (men r = 0.50, p = 0.0004; women r = 0.22, p = 0.048). 4-MM was associated with handgrip strength and 6MWT in both men and women. Considering gait speed <0.6 m/s as diagnostic of dismobility syndrome, the two methods of assessment disagreed, with a different categorization of subjects, in 19% of men and 23% of women. The use of accelerometer resulted in 29 (13 M, 16 F) additional diagnoses of dismobility, compared with the 4-MM. Conclusions In an older population, the concordance of gait speeds manually or instrumentally assessed is not optimal. The results suggest that manual measures might lead to misclassification of a substantial number of subjects. However, longitudinal studies using standardized and validated procedures aimed at the comparison of different techniques are needed before recommending the use of accelerometers in comprehensive geriatric assessment. PMID:27077744

  17. Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals.

    PubMed

    Maggio, Marcello; Ceda, Gian Paolo; Ticinesi, Andrea; De Vita, Francesca; Gelmini, Giovanni; Costantino, Cosimo; Meschi, Tiziana; Kressig, Reto W; Cesari, Matteo; Fabi, Massimo; Lauretani, Fulvio

    2016-01-01

    Manual measurement of 4-meter gait speed by a stopwatch is the gold standard test for functional assessment in older adults. However, the accuracy of this technique may be biased by several factors, including intra- and inter-operator variability. Instrumental techniques of measurement using accelerometers may have a higher accuracy. Studies addressing the concordance between these two techniques are missing. The aim of the present community-based observational study was to compare manual and instrumental measurements of 4-meter gait speed in older individuals and to assess their relationship with other indicators of physical performance. One-hundred seventy-two (69 men, 103 women) non-disabled community-dwellers aged ≥65 years were enrolled. They underwent a comprehensive geriatric assessment including physical function by Short Physical Performance Battery (SPPB), hand grip strength, and 6-minute walking test (6MWT). Timed usual walking speed on a 4-meter course was assessed by using both a stopwatch (4-meter manual measurement, 4-MM) and a tri-axial accelerometer (4-meter automatic measurement, 4-MA). Correlations between these performance measures were evaluated separately in men and women by partial correlation coefficients. In both genders, 4-MA was associated with 4-MM (men r = 0.62, p<0.001; women r = 0.73, p<0.001), handgrip strength (men r = 0.40, p = 0.005; women r = 0.29, p = 0.001) and 6MWT (men r = 0.50, p = 0.0004; women r = 0.22, p = 0.048). 4-MM was associated with handgrip strength and 6MWT in both men and women. Considering gait speed <0.6 m/s as diagnostic of dismobility syndrome, the two methods of assessment disagreed, with a different categorization of subjects, in 19% of men and 23% of women. The use of accelerometer resulted in 29 (13 M, 16 F) additional diagnoses of dismobility, compared with the 4-MM. In an older population, the concordance of gait speeds manually or instrumentally assessed is not optimal. The results suggest that manual measures might lead to misclassification of a substantial number of subjects. However, longitudinal studies using standardized and validated procedures aimed at the comparison of different techniques are needed before recommending the use of accelerometers in comprehensive geriatric assessment.

  18. Perimetric measurements with flicker-defined form stimulation in comparison with conventional perimetry and retinal nerve fiber measurements.

    PubMed

    Horn, Folkert K; Tornow, Ralf P; Jünemann, Anselm G; Laemmer, Robert; Kremers, Jan

    2014-04-11

    We compared the results of flicker-defined form (FDF) perimetry with standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements using spectral domain optical coherence tomography (OCT). A total of 64 healthy subjects, 45 ocular hypertensive patients, and 97 "early" open-angle glaucoma (OAG) patients participated in this study. Definition of glaucoma was based exclusively on glaucomatous optic disc appearance. All subjects underwent FDF perimetry, SAP, and peripapillary measurements of the RNFL thickness. The FDF perimetry and SAP were performed at identical test locations (G1 protocol). Exclusion criteria were subjects younger than 34 years, SAP mean defect (SAP MD) > 5 dB, eye diseases other than glaucoma, or nonreliable FDF measurements. The correlations between the perimetric data on one hand and RNFL thicknesses on the other hand were analyzed statistically. The age-corrected sensitivity values and the local results from the controls were used to determine FDF mean defect (FDF MD). The FDF perimetry and SAP showed high concordance in this cohort of experienced patients (MD values, R = -0.69, P < 0.001). Of a total of 42 OAG patients with abnormal SAP MD, 38 also displayed abnormal FDF MD. However, FDF MD was abnormal in 28 of 55 OAG patients with normal SAP MD. The FDF MD was significantly (R = -0.61, P < 0.001) correlated with RNFL thickness with a (nonsignificantly) larger correlation coefficient than conventional SAP MD (R = -0.48, P < 0.001). The FDF perimetry is able to uncover functional changes concurrent with the changes in RNFL thickness. The FDF perimetry may be an efficient functional test to detect early glaucomatous nerve atrophy. (ClinicalTrials.gov number, NCT00494923.).

  19. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis.

    PubMed

    Khangura, Jaspreet; Culleton, Bruce F; Manns, Braden J; Zhang, Jianguo; Barnieh, Lianne; Walsh, Michael; Klarenbach, Scott W; Tonelli, Marcello; Sarna, Magdalena; Hemmelgarn, Brenda R

    2010-06-24

    Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  20. Comparison between electromagnetic transponders and radiographic imaging for prostate localization: A pelvic phantom study with rotations and translations.

    PubMed

    Hamilton, Daniel G; McKenzie, Dean P; Perkins, Anne E

    2017-09-01

    The aim of this study was to evaluate the differences in target localization between Calypso ® , kV orthogonal imaging and cone-beam computed tomography (CBCT) for combined translations and rotations of an anthropomorphic pelvic phantom. The phantom was localized using all three systems in 50 different positions, with applied translational and rotational offsets randomly sampled from representative normal distributions of prostate motion. Lin's concordance correlation coefficient (ρc) and 95% confidence intervals were calculated to assess the agreement between the localization systems. Mean differences and difference vectors between the three systems were also calculated. Agreement between systems for lateral, vertical, and longitudinal translations was excellent, with ρc values of greater than 0.98 between all three systems in all axes. There was excellent agreement between the systems for rotations around the lateral axis (pitch) (ρc > 0.99), and around the vertical axis (yaw) (ρc > 0.97). However, somewhat poorer agreement for rotations around the longitudinal axis (roll) was observed, with the lowest correlation observed between Calypso and kV orthogonal imaging (ρc = 0.895). Mean differences between the phantom position reported by Calypso and the radiographic systems were less than 1 mm and 1° for all translations and rotations. The results for translations are consistent with the publications of previous authors. There is no comparable published data for rotations. While there is lower correlation between the three systems for roll than for the other angles, the mean differences in reported rotations are not clinically significant. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Top